1 StructuredGround Direct urial Compression Grounding System The StructuredGround Direct urial Compression Grounding System provides the highest performance and most reliable compression connection in the industry. This system offers the speed and safety of a compression connection, while exceeding the stringent requirements of IEEE Std The fully inspectable system that is U 467 isted and CS 22.2 Certified, ensures that the installed product operates safely. ide range-taking and universal designs provide installation flexibility with a minimum number of parts, reducing procurement and inventory costs. Innovative features assure a high quality bond, reducing labor costs and improving crimp quality. Key Features Meets IEEE Std enefits Offers the speed and safety of a compression connection while exceeding the stringent requirements of the recently revised standard, through patent pending crimp technology for maximum reliability D RTED Exceeds U 467 and CS 22.2 with or industry standard crimping tools and crimping dies Complies with MI-STD-202G (METHOD 201) Compression connection ide range-taking ability and multi-conductor designs Pre-applied conductive antioxidant compound Slotted tap design and locator die Standards compliance and full inspectability ensures that the installed product operates safely, while reducing installation tool costs and providing convenience Reliable performance in high vibration environments Non-flammable process that installs quickly and safely in any weather condition Provide design and installation flexibility with a minimum number of parts, reduce procurement costs, ease inventory management, and improve availability to meet critical project schedules Ensures a high quality mechanical and electrical bond, speeding installation Speeds installation time, reduces labor costs and improves crimp quality pplications Oil and Gas Industrial Facilities Cell Towers Construction

2 StructuredGround Direct urial Compression Grounding System Meets the most stringent industry standards while offering unmatched ease of installation and safety. hy Does This Matter? Grounding is a critical functioning part of the electrical system. The integrity of your grounding system is dependent upon your connectors withstanding the environment in which they are installed. chieving this reliability, while maximizing safety and speeding installation ensures a grounding system that will provide you with the greatest value. ith the StructuredGround Direct urial Compression Grounding System, you benefit from a connector that meets the highest performance specification in the industry, faster installation, ensured safety in any weather condition, with a minimum investment in tooling and inventory. Meets IEEE Std the Premier Test of Corrosion Resistance The IEEE Green ook, IEEE Recommended Practice for Grounding of Industrial and Commercial Power Systems (IEEE Std ), states: (i)t is recommended that [grounding] connections meet the requirements of IEEE Std 837. The purpose of the IEEE Std 837 for Qualifying Permanent Connections used in Substation Grounding standard is to give assurance to the user that a connection meeting the requirements of this standard will perform in a satisfactory manner over the lifetime of the installation. IEEE Std 837 goes beyond the testing required by U 467 and CS 22.2, requiring sequences of environmental simulations including: lightning strike, freeze-thaw cycling, and chemical corrosion, to provide better assurance that the grounding system will remain viable throughout its installed life. IEEE Std is Now an Even Tougher Test of Corrosion Resistance than IEEE Std In 2002, the acceptance criteria for the IEEE Std 837 test was revised, making it more difficult to pass. s a result, connectors that meet the 2002 revision of 837 reduce the risk associated with a given installation by providing a more robust barrier against the corrosive elements that could otherwise cause the grounding system to fail. s enhanced crimp process, using patent pending technology, achieves the new performance requirements, providing unmatched verification of corrosion resistance. See page 8. Reduces Installation Costs Can be installed in any weather from extreme cold to wet conditions the StructuredGround Direct urial Compression Grounding System will keep your construction project on time and on budget ide range-taking components can go from #6 to 250 kcmil wire with only five parts, minimizing inventory and tool investment Only a single die required to crimp each element Full inspectability die index numbers are embossed on the connector body during the crimp process allowing the inspector to quickly and easily identify a proper installation Increases Job-Site Safety No weld connections special protective equipment or extra clothing is not required Full inspectability die index numbers are embossed on the connector body during the crimp process allowing the inspector to quickly and easily identify a proper installation Hydraulic and battery operated compression connection crimping tools reduce operator stress and fatigue 2 For the most reliable direct burial grounding system, specify connectors meeting IEEE Std

3 Conductor to Conductor E Style and Cross Connectors: Creates bonds between parallel grounding conductors. See pages 4 & 5 4 Conductor to uilding Steel Universal eam Grounding Clamp: onds structural steel to grounding conductor system. See page 6 2 Conductor to Rebar E Style and Cross Connectors: llows bonds to reinforcing bars. See pages 4 & 5 5 Conductor to Grounding Electrodes Grounding Plate Connector: llows bonds through concrete. See page 6 3 Conductor to Ground Rod 6 Related Product CC- E Style and Cross Connectors: Creates bonds between perpendicular grounding conductors. See pages 4 & 5 ong arrel Two-Hole Code Conductor ugs: For use with stranded copper conductors. Visit for complete part details. C equipment should be grounded per NEC standards. Enclosures should be grounded per manufacturer's specifications. 3

4 StructuredGround Direct urial Compression Grounding System D RTED E Style Grounding Connectors ide range-taking ability and multi-conductor design provide flexibility with a minimum number of parts, allowing for conductor to conductor, conductor to rebar, and conductor to ground rod applications Designed for the enhanced crimp process using patent pending technology which meets IEEE Std Slotted design allows quick and easy assembly of conductor to connector using cable ties, included Patented pre-applied conductive antioxidant compound ensures a high quality mechanical and electrical bond, speeding installation Color-coded and marked with die index numbers for proper crimp die selection U 467 isted and CS 22.2 Certified for grounding and bonding suitable for direct burial in earth or concrete when crimped with or industry standard crimping tools and dies Complies with vibration tests per MI-STD-202G (METHOD 201) Views using cable ties H H H H H? GCE1/0-1/0 GCE250-1/0 GCE GCE500-1/0 GCE GCE1/0-1/0 GCE250-1/0 GCE GCE500-1/0 GCE Element Copper Conductor Range G (mm 2 ) #6 SO 1/0 STR 1/0 STR 250 kcmil (70-120) #6 SO 1/0 STR 1/0 STR 250 kcmil (70 120) kcmil ( ) #6 SO 1/0 STR (16-50) kcmil ( ) 1/0 STR 250 kcmil (70 120) Ground Rod Rebar H (23.9) (16.8) (43.7) 3/8 1/2, #3 #4 ( ), (#10 #13) (25.4) (26.7) (55.4) 1/2 5/8 ( ) 1/2 5/8 ( ) 1/2 3/4 ( ) 3/8 1/2, #3 #4 ( ), (#10 #13) (25.4) (27.4) (67.6) 5/8 3/4, #5 # (25.4) (34.5) (67.1) 1/2 3/4 ( ) 5/8 3/4, #5 #6 ( ), (#16 #19) 1.00 (25.4) *See page 8 for crimp process details. See page 7 for a complete list of installation tooling and die selections. Figure Dimensions (33.4) (72.4) Color Code Die Index No. Crimp Process* U isted and CS Certified IEEE Std Red PG10 1 Traditional Traditional lack PG25 1 Traditional Enhanced lue PG50 1 Traditional Enhanced 4

5 D RTED Grounding Cross Connectors Only a single die required to crimp each element, which speeds installation and reduces costs ide range-taking ability and multi-conductor design provide flexibility with a minimum number of parts, allowing for conductor to conductor, conductor to rebar, and conductor to ground rod applications Designed for the enhanced crimp process using patent pending technology which meets IEEE Std Slotted design allows quick and easy assembly of conductor to connector using cable ties, included Patented pre-applied conductive antioxidant compound ensures a high quality mechanical and electrical bond, speeding installation Color-coded and marked with die index numbers for proper crimp die selection U 467 isted and CS 22.2 Certified for grounding and bonding suitable for direct burial in earth or concrete when crimped with or industry standard crimping tools and dies Complies with vibration tests per MI-STD-202G (METHOD 201) Exclusive Single Die Crimps oth Elements H H H H H Element Element Element Element Element H H H H H Element Element Element Element Element GCC6X61/0-1/0 3/8" ROD GCC6X6250-1/0 9/16" ROD GCC6X /16" ROD GCC6X6500-1/0 9/16" ROD GCC6X /16" ROD GCC6X61/0-1/0 GCC6X6250-1/0 GCC6X GCC6X6500-1/0 GCC6X Element Copper Conductor Range G (mm 2 ) #6 SO 1/0 STR #2 SO 250 kcmil (35 120) #6 SO 1/0 STR #2 SO 250 kcmil (35 120) kcmil ( ) #6 SO 1/0 STR kcmil ( ) #2 SO 250 kcmil (35 120) Ground Rod Rebar 1/2 5/8 ( ) 3/8 1/2, #3 #4 ( ), (#10 #13) 1.00 (25.4) 1/2 5/8 ( ) 1/2 3/4 ( ) 3/8 1/2, #3 #4 ( ), (#10 #13) 5/8 3/4, #5 #6 ( ), (#16 #19) /2 3/4 ( ) 5/8 3/4, #5 #6 ( ), (#16 #19) 1.00 *See page 8 for crimp process details. See page 7 for a complete list of installation tooling and die selections. Figure Dimensions H (23.9) (16.8) (34.8) (53.8) (26.9) 1.68 (42.7) (25.4) (26.9) (53.8) (33.5) (63.0) (25.4) (27.7) (49.3) (33.5) (63.0) (25.4) (29.5)(58.2) Color Code Die Index No. Crimp Process* U isted and CS Certified IEEE Std Red PG10 1 Traditional Traditional lack PG25 1 Traditional Enhanced lue PG50 1 Traditional Enhanced 5

6 StructuredGround Direct urial Compression Grounding System D RTED Universal, fits on a wide range of standard (angled) and wide flange (parallel) structural steel beams Provides a mounting pad suitable for a two-hole compression lug Installs quickly and easily with standard 1/4 inch key hex wrench tooling Universal eam Grounding Clamp U 467 isted and CS 22.2 Certified for grounding and bonding suitable for direct burial in earth or concrete Complies with vibration tests per MI-STD-202G (METHOD 201) H GUC500-6 Copper Conductor Range G (mm 2 ) #6 G 500 kcmil (16 240) Flange Thickness ( ) Slotted design allows quick and easy assembly of conductor to connector using cable ties included Patented pre-applied conductive antioxidant compound ensures a high quality mechanical and electrical bond, speeding installation Complies with vibration tests per MI-STD-202G (METHOD 201) Thread In. 1/2 13 Grounding Plate Connector Figure Dimensions H For stainless steel mounting hardware kit, order part number GMHK (includes two hex head bolts, two split lock washers and two SE flat washers). D RTED 1.75 (44.4) 3.15 (80.0) 2.13 (54.0) 2.50 (63.5) Made from high conductivity copper; provides strength and premium electrical properties Color-coded and marked with die index numbers for proper crimp die selection U 467 isted and CS 22.2 Certified for grounding and bonding suitable for direct burial in earth or concrete when crimped with or industry standard crimping tools and dies 1 Y H C GPC4H250-2 Copper Conductor Range G (mm 2 ) #2 SO 250 kcmil (35 120) Thread In. 1/2 13 Figure Dimensions H Y C 5.81 (147.5) 3.31 (84.0) 3.58 (90.9) 1.97 (50.0) 1.75 (44.5) 1.75 (44.5) 1.26 (32.0) Color Code Die Index No. Crimp Process* U isted and CS Certified IEEE Std lack PG25 1 Traditional Enhanced For stainless steel mounting hardware kit, order part number GMHK (includes two hex head bolts, two split lock washers and two SE flat washers). *See page 8 for crimp process details. See page 7 for a complete list of installation tooling and die selections. ocator Dies ocating rib feature positions tap, ensuring full-width crimp Color-coded for easy matching to color coding marked on connectors Embosses die index number on connector barrels for post crimp inspection Part number permanently marked on crimp die for easy identification Provides circumferential crimp resulting in terminations with premium electrical and mechanical performance 6 Used to Install s Copper Copper Die Color and No. CD-930G-1/0 GCE1/0-1/0, GCC6X61/0-1/0 Red PG10 1 CD-930G-250 GCE250-1/0, GCE , GCC6X6250-1/0, GCC6X , GPC4H250-2 lack PG25 1 CD-930G-500 GCE500-1/0, GCE , GCC6X6500-1/0, GCC6X lue PG50 1 *See page 8 for crimp process details. See page 7 for a complete list of installation tooling and die selections.

7 Installation Tooling and Die Selections for Types GCE, GCC, and GPC How to read this chart For GCE250-1/0 and CT-2930 tool: GCE1/0-1/0 Color Code Die Part Number CD-930G-250 lack PG25 (1) Number of Crimps Die Index Number Installation Tools 12 TON 14 TON 15 TON CT-2931 Y750, Y750-2, Y750H, Y750H-2, T750-14V, PT750-18V, PT750C-18V, PT750XT-18V, PT750CXT-18V, PHY750 CT-930 CT-930CH CT-2930 CT-2930/ CT-2930/E urndy Thomas & etts TM14M, TM14MC, 13100, TM14RH, TM14SCR, PT14SCRI CT-940CH CT-2940 CT-2940/ CT-2940/E Y46, Y46C, PHY46 TM15 TM15SCR Crimp Die Part Ground Rod Rebar Copper Conductor Number/Color Code/Die Index Element Range In. In. Number/(Number of Crimps) #6 G SO 1/0 G STR CD-930G-1/0 #6 G SO 1/0 G STR Red GCC6X61/0-1/0 GCE250-1/0 GCC6X6250-1/0 GCE #6 G SO 1/0 G STR PG10 #6 G SO 1/0 G STR (1) 1/0 G SO 250 kcmil 1/2 5/8 3/8 1/2, #3 #4 CD-930G-250 #6 G SO 1/0 G STR lack #2 G SO 250 kcmil 1/2 5/8 3/8 1/2, #3 #4 PG25 #6 G SO 1/0 G STR (1) 1/0 G SO 250 kcmil 1/2 5/8 3/8 1/2, #3 #4 CD-930G-250 1/0 G SO 250 kcmil 1/2 5/8 3/8 1/2, #3 #4 lack #2 G SO 250 kcmil 1/2 5/8 3/8 1/2, #3 #4 PG25 GCE6X #2 G SO 250 kcmil 1/2 5/8 3/8 1/2, #3 #4 (1) GPC4H250-2 #2 G SO 250 kcmil GCE500-1/0 GCC6X6500-1/0 GCE GCC6X kcmil 1/2 3/4 5/8 3/4, #5 #6 CD-930G-500 #6 G SO 1/0 G STR lue kcmil 1/2 3/4 5/8 3/4, #5 #6 PG50 #6 G SO 1/0 G STR (1) kcmil 1/2 3/4 5/8 3/4, #5 #6 CD-930G-500 1/0 G SO 250 kcmil lue kcmil 1/2 3/4 5/8 3/4, #5 #6 PG50 #2 G SO 250 kcmil (1) 15 ton tools require the CD-940-D adapter when used with CD-930G series crimping dies. crimping dies must be used with all tooling ( and competitor). 7

8 StructuredGround Direct urial Compression Grounding System Traditional Crimp Process** STEP 1) Position tap in die and crimp The traditional crimp process embosses the die number on the part once, for full inspectability **GCE1/0-1/0 and GCC6X61/0-1/0 achieve IEEE Std through the traditional crimp process. Enhanced Crimp Process Using Patent Pending Technology STEP 1) Position tap in die and crimp STEP 3) Reposition crimping tool, position tap in die and crimp STEP 2) Reposition crimping tool, identify slotted tap design, align with locator die and crimp The enhanced crimp process embosses the die number on the part twice, for full inspectability Reposition Crimping Tool Die ocator ORDIDE SUSIDIRIES ND SES OFFICES PNDUIT CND Markham, Ontario Phone: PNDUIT EUROPE TD. ondon, UK Phone: PNDUIT SINGPORE PTE. TD. Republic of Singapore Phone: PNDUIT JPN Tokyo, Japan Phone: PNDUIT TIN MERIC Guadalajara, Mexico Phone: PNDUIT USTRI PTY. TD. Victoria, ustralia Phone: For a copy of product warranties, log on to For more information Visit us at Contact Customer Service by cs@panduit.com or by phone: and reference GRC Corp. RIGHTS RESERVED. Printed in the U.S.. Product ulletin Number S-GRC05 8/2011

Product Bulletin. VeriSafe Absence of Voltage Tester. The Safe Way to Verify the Absence of Voltage.

Product Bulletin. VeriSafe Absence of Voltage Tester. The Safe Way to Verify the Absence of Voltage. Product Bulletin VeriSafe Absence of Voltage The Safe Way to Verify the Absence of Voltage. When servicing electrical equipment, workers must comply with safety regulations that require a voltage verification

More information

Product Bulletin. VeriSafe Absence of Voltage Tester. The Safe Way to Verify the Absence of Voltage.

Product Bulletin. VeriSafe Absence of Voltage Tester. The Safe Way to Verify the Absence of Voltage. Product Bulletin The Safe Way to Verify the Absence of Voltage. When servicing electrical equipment, workers must comply with safety regulations that require a voltage verification test to validate the

More information

Easy to use, initiate test with the push of a button No additional tools required Provides visual alert to abnormal power conditions

Easy to use, initiate test with the push of a button No additional tools required Provides visual alert to abnormal power conditions Product Bulletin VeriSafe Absence of Voltage The Safe Way to Verify the Absence of Voltage. When servicing electrical equipment, workers must comply with safety regulations that require a voltage verification

More information

Designed for testing three-phase circuits up to 600V Install on line or load side of electrical disconnect Detects absence of AC and DC voltage

Designed for testing three-phase circuits up to 600V Install on line or load side of electrical disconnect Detects absence of AC and DC voltage Product Bulletin VeriSafe Absence of Voltage The Safe Way to Verify the Absence of Voltage. When servicing electrical equipment, workers must comply with safety regulations that require a voltage verification

More information

GROUNDING AND BONDING

GROUNDING AND BONDING PHYSICAL INFRASTRUCTURE SYSTEMS GROUNDING AND ONDING Panduit grounding and bonding solutions meet customer needs and today s critical application requirements for grounding data centers and telecommunication

More information

Product Bulletin. VeriSafe Absence of Voltage Tester. The Safe Way to Verify the Absence of Voltage.

Product Bulletin. VeriSafe Absence of Voltage Tester. The Safe Way to Verify the Absence of Voltage. Product Bulletin VeriSafe Absence of Voltage The Safe Way to Verify Absence of Voltage. When servicing electrical equipment, workers must comply with safety regulations that require a voltage verification

More information

SECTION ELECTRICAL GENERAL PROVISIONS

SECTION ELECTRICAL GENERAL PROVISIONS PART 1 GENERAL 1.01 SECTION INCLUDES A. General provisions for Electrical Systems B. Wire and cable for 600 volts and less. C. Wiring connectors. D. Electrical tape. E. Heat shrink tubing. F. Wire pulling

More information

CT-930CH, CT-930LPCH and CT-940CH TABLE OF CONTENTS

CT-930CH, CT-930LPCH and CT-940CH TABLE OF CONTENTS CT-930CH, CT-930LPCH and CT-940CH PA22141A01 Rev. 03 5-2012 REMOTE HYDRAULIC COMPRESSION TOOLS Panduit Corp. 2012 TABLE OF CONTENTS SYSTEM SPECIFICATIONS... 1 OPTIONAL ACCESSORIES... 2 PRECAUTIONS AND

More information

HBBBxxxx Busbars. None. HGBL: Lugs HYG14B: Busbar Taps HGRKT: Ground Kits HPENE: Penetrox anti oxidant

HBBBxxxx Busbars. None. HGBL: Lugs HYG14B: Busbar Taps HGRKT: Ground Kits HPENE: Penetrox anti oxidant HBBBxxxx Busbars Product Launch Summary * * INTERNAL USE ONLY * * Date: 01/23/2012 Copper Busbars are used in the Service Entrance, Telecommunications Room, Data Center, and on Equipment Racks. All busbar

More information

P-16 ENGINEER NO. DATE DESCRIPTION 1 01/19/2016 FOR CONSTRUCTION 2 03/11/2016 REVISION # 2 DRAWN BY: CHECKED BY: DATE: SCALE: DRAWING NUMBER

P-16 ENGINEER NO. DATE DESCRIPTION 1 01/19/2016 FOR CONSTRUCTION 2 03/11/2016 REVISION # 2 DRAWN BY: CHECKED BY: DATE: SCALE: DRAWING NUMBER PRESSIONAL P-16 PRESSIONAL PRESSIONAL PRESSIONAL 1 ONE LINE DIAGRAM 3 EMEGENCY LIGHTING SCHEME 2 FEEDER SCHEDULE PRESSIONAL PRESSIONAL PRESSIONAL PRESSIONAL LOCAL SINGLE POLE SWITCH 3-WAY SWITCH 3-WAY

More information

PRODUCTS FOR Wiring Duct Power & Grounding Connectors Fastening Products Control Termination Identification Solutions

PRODUCTS FOR Wiring Duct Power & Grounding Connectors Fastening Products Control Termination Identification Solutions PRODUCTS FOR Head Office 700 Thomas Avenue Saint-Jean-sur-Richelieu, Quebec J2X 2M9 Tel.: (450) 347-5318 Fax: (450) 347-1976 Wiring Duct Power & Grounding Connectors Atlantic Region Regional Sales Offices

More information

You work hard on your panel. we work hard in your panel. PRODUCTS FOR

You work hard on your panel. we work hard in your panel. PRODUCTS FOR You work hard on your panel we work hard in your panel. PRODUCTS FOR 2 PRODUCTS FOR You simply won t find better panel components. Thomas & Betts has everything you need to make your panel better than

More information

INTER PLANT STANDARD STEEL INDUSTRY

INTER PLANT STANDARD STEEL INDUSTRY INTER PLANT STANDARD STEEL INDUSTRY IPSS CODE OF PRACTICE FOR END TERMINATION AND JOINTING OF CABLES BY COMPRESSION MEHOD AND SPECIFICATION FOR DIELESS HYDRAULICALLY OPERATED CRIMPING TOOL (First Revision)

More information

D100 SERIES HYDRAULIC HOSE CRIMPER OPERATORS MANUAL

D100 SERIES HYDRAULIC HOSE CRIMPER OPERATORS MANUAL D00 SERIES HYDRAULIC HOSE CRIMPER OPERATORS MANUAL Page 2 MODELS COVERED This manual is applicable to different versions of the D_00_ Series Crimpers. A Standard, Metric and DC micrometer is available

More information

Terminal lugs for LV power cables with aluminum conductors

Terminal lugs for LV power cables with aluminum conductors CLASS PROGRAMME Type approval DNVGL-CP-0409 Edition January 2018 Terminal lugs for LV power cables with aluminum conductors The content of this service document is the subject of intellectual property

More information

FOR TM-16 EMERGENCY WARNING SYSTEM

FOR TM-16 EMERGENCY WARNING SYSTEM INSTALLATION AND INSTRUCTION MANUAL FOR TM-16 EMERGENCY WARNING SYSTEM SPECIAL NOTE BOONE CABLE WORKS & ELECTRONICS, INC. 1773-219 TH LANE P.O. BOX 429 READ THIS ENTIRE BOOKLET BOONE, IOWA 50036 USA BEFORE

More information

HYDRAULIC CRIMPING TOOL

HYDRAULIC CRIMPING TOOL HYDRAULIC CRIMPING TOOL HT 120 Crimping force kn 120 488 138 5,7 This lightweight and self contained tool will accept the semi-circular slotted dies, coon to most 130 kn tools. It is particularly suitable

More information

HYDRAULIC CRIMPING TOOL HYDRAULIC PRESSHEAD

HYDRAULIC CRIMPING TOOL HYDRAULIC PRESSHEAD HYDRAULIC CRIMPING TOOL HT 51 50 380 130 2,7 End sleeves Connectors 185 70 50 70 VAL P1* 445x290xh95 1,2 * Suitable for storage of the tool and 20 sets of dies. also the HT 51-KV version, for power supply

More information

Mechanical Crimping Tool JT-150 Instruction Manual

Mechanical Crimping Tool JT-150 Instruction Manual 500.630 Mechanical Crimping Tool JT-150 Instruction Manual Due to continuing improvements, actual product may differ slightly from the product described herein. General Safety Rules To work in safe conditions

More information

SECTION LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES (600 VOLTS AND BELOW)

SECTION LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES (600 VOLTS AND BELOW) SECTION 26 05 21 PART 1 - GENERAL 1.1 DESCRIPTION This section specifies the furnishing, installation, and connection of the low voltage power and lighting wiring. 1.2 RELATED WORK A. Excavation and backfill

More information

A. Connected to the equipment ground B. Bonded to the box C. Connected to nearest water pipe D. Connected to a ground rod

A. Connected to the equipment ground B. Bonded to the box C. Connected to nearest water pipe D. Connected to a ground rod Journeyman and Master Common Exam 2 1 The grounding terminal of a grounding-type receptacle installed in a metal box shall be? A. Connected to the equipment ground B. Bonded to the box C. Connected to

More information

Part Number: RCSTR INSTRUCTIONS CM450 SAFETY REQUIREMENTS

Part Number: RCSTR INSTRUCTIONS CM450 SAFETY REQUIREMENTS Caster Bracket Kit for 4 Post Racks Part Number: RCSTR Panduit Corp. 2010 INSTRUCTIONS CM450 SAFETY REQUIREMENTS CAUTION Do not attempt to move racks by yourself. Obtain adequate assistance to move racks.

More information

SECTION (16460) - LOW-VOLTAGE TRANSFORMERS

SECTION (16460) - LOW-VOLTAGE TRANSFORMERS PART 1 GENERAL 1.01 SUMMARY SECTION 26 22 00 (16460) - LOW-VOLTAGE TRANSFORMERS A. Section Includes: 1. Dry-Type Distribution And Specialty Transformers Rated 1000 V And Less. a. General-Purpose Distribution

More information

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels Installation Instructions For the 18 Built-In Dishwasher and Front Color Panels Printed in USA 154232102 Before You Begin DO NOT INSTALL DISHWASHER UNTIL YOU HAVE READ ALL INSTRUCTIONS. FOR YOUR SAFETY,

More information

MICHIGAN S ONLY AUTHORIZED WARRANTY SERVICE CENTER. Industrial Equipment Rental & Service

MICHIGAN S ONLY AUTHORIZED WARRANTY SERVICE CENTER. Industrial Equipment Rental & Service MICHIGAN S ONLY AUTHORIZED WARRANTY SERVICE CENTER Industrial Equipment Rental & Service Bending Classic Electric Bender for Conduit & Pipe Item #555C Electric Bender Item #854DX Bend 1/2" to 2" RIGID/IMC/EMT

More information

Revisions to this application specification include: Updated document to corporate requirements Changed product types in table in Figure 6

Revisions to this application specification include: Updated document to corporate requirements Changed product types in table in Figure 6 This specification covers the requirements for application of PLASTI GRIP Terminals and Splices for commercial applications. The terminals and splices consist of precision formed metal wire barrel insulated

More information

KH-80 HYDRAULIC CRIMPER OPERATORS MANUAL

KH-80 HYDRAULIC CRIMPER OPERATORS MANUAL KH-80 HYDRAULIC CRIMPER OPERATORS MANUAL 1 SAFETY PRECAUTIONS READ AND IDENTIFY ALL COMPONENT PARTS BEFORE USING CRIMPER. CRIMPER CAN PRODUCE 80 TONS OF FORCE. KEEP BOTH HANDS AWAY FROM PINCH POINTS. CONSULT

More information

MobileCrimp Crimper Die Selection Table For MegaCrimp. MobileCrimp. Die Sets (ordered separately) Digital Dial Control

MobileCrimp Crimper Die Selection Table For MegaCrimp. MobileCrimp. Die Sets (ordered separately) Digital Dial Control MobileCrimp 4-20 Crimper This lightweight, versatile crimper is powerful enough to crimp up to 1-1/4" four spiral-wire hose Weighing approximately 57 pounds, this new field crimper combines the latest

More information

Mechman 170-Amp Alternator Cable Kit (220013)

Mechman 170-Amp Alternator Cable Kit (220013) an ISO 900:2008 Registered Company Mechman 70-Amp Alternator Cable Kit (22003) 8865 Goll St. San Antonio, TX 78266 Phone: 20-654-77 Fax: 20-654-33 www.vintageair.com 90723 REV B 07/29/6, PG OF 8 Table

More information

Band Heaters W A T L O W. Special Mica Barrel and Nozzle

Band Heaters W A T L O W. Special Mica Barrel and Nozzle W A T L O W For over 80 years, Watlow has been solving complex and unique application problems with standard mica barrel and nozzle heaters. Watlow is continuously improving design and application knowledge

More information

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION PUMPS

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION PUMPS PART 0 A/E INSTRUCTIONS 0.01 Design Requirements A. Pumping system design 1. A primary-secondary pumping system is preferred. Redundant pipes are required for chillers and boilers. 2. Select pumps to operate

More information

Thermo-Platens. Cast-In Aluminum and Bronze Platen Die Heaters for Plastics Processing Equipment

Thermo-Platens. Cast-In Aluminum and Bronze Platen Die Heaters for Plastics Processing Equipment Cast-In Aluminum and Bronze Platen Die Heaters for Plastics Processing Equipment Cast-In Platen Heaters are widely accepted as the industry standard for heating critical, temperaturesensitive plastics

More information

CORDLESS HYDRAULIC TOOLS

CORDLESS HYDRAULIC TOOLS CORDLESS HYDRAULIC TOOLS 18.0 V - 4.0 Ah CORDLESS TOOL FEATURES Head rotates through 180. Switch protected against accidental operation. Pressure release button. Slot-in battery with release button. LED

More information

Miniature Hobby Boiler Inspection and Certification Requirements

Miniature Hobby Boiler Inspection and Certification Requirements State of Washington Department of Labor & Industries Boiler & Pressure Vessel Program 7273 Linderson Way S.W. Tumwater, Washington 98501 Miniature Hobby Boiler Inspection and Certification Requirements

More information

AS/NZS :2003 Luminaires - Part 1: General requirements and tests

AS/NZS :2003 Luminaires - Part 1: General requirements and tests Menu Home About this portal Latest updates Print Save Email Resource detail Citations AS/NZS 60598.1:2003 Luminaires - Part 1: General requirements and tests Table of Contents View on Information Provider

More information

AX51 with Munters Drive

AX51 with Munters Drive Instruction Manual AX51 with Munters Drive Fan Hanger Kit AX Hanger Kit and I Beam hardware AX51 with Munters Drive Fan Hanger Kit Models: FH1712 AX Hanger Kit AX51with Munters Drive Fan Munters Corporation,

More information

1SC-SSC Splice Connection Kit Installation Instructions

1SC-SSC Splice Connection Kit Installation Instructions 1SC-SSC Splice Connection Kit Installation Instructions Description The 1SC-SSC is a NEMA 4 rated splice connection kit for use with Raychem 1SC30, 40, 50, 60, 70, 80 (-CT) and 1SC/H30, 40, 50, 60, 70,

More information

ABH BASIN HEATER CONTROLS PACKAGE. engineering data and specifications

ABH BASIN HEATER CONTROLS PACKAGE. engineering data and specifications BH BSIN HETER CONTROLS PCKGE engineering data and specifications BH Basin Heater Control Package 2 BH DVNCED BSIN HETER CONTROLS The Marley BH basin heater package controls the ON and OFF operation of

More information

From the World Leader in VRLA Battery Technology

From the World Leader in VRLA Battery Technology From the World Leader in VRLA Battery Technology Designed for durability in Telecommunications, and Electric Utility applications, the GNB FRONT Terminal MARATHON TM series provides high performance and

More information

GREENLEE CUTTING, CABLE STRIPPING, CRIMPING

GREENLEE CUTTING, CABLE STRIPPING, CRIMPING Manual Crimping Tool 6-Ton -Powered Crimping Tools EK22GL11 K425BG K425O 02064 Crimping Tool with D 3 and O die grooves K425BG 02065 Crimping Tool with D 3 and BG die grooves Designed for crimping a wide

More information

KEE & SEE URAS VIBRATORS

KEE & SEE URAS VIBRATORS KEE & SEE URAS VIBRATORS Features: Fully enclosed: All vibrator housings are totally enclosed and are suited for use in dusty environment which meet the requirements of the IP-66, International Protection

More information

HK1230 and HK1230C Hydraulic Crimping Tools

HK1230 and HK1230C Hydraulic Crimping Tools INSTRUCTION MANUAL HK1230 and HK1230C Hydraulic Crimping Tools Read and understand all of the instructions and safety information in this manual before operating or servicing this tool. Register this product

More information

INSTALLATION INSTRUCTIONS John Deere One Series; 1023E, 1025R and 1026R Models A HEATER KIT. Figure 1 (General Layout and Parts I.D.

INSTALLATION INSTRUCTIONS John Deere One Series; 1023E, 1025R and 1026R Models A HEATER KIT. Figure 1 (General Layout and Parts I.D. A-11978 HEATER KIT Figure 1 (General Layout and Parts I.D.) Read these instructions and identify all components. Please retain these instructions for future reference and parts ordering information. Refer

More information

Cartridge Heaters. Metric FIREROD Cartridge. Applications and Technical Data

Cartridge Heaters. Metric FIREROD Cartridge. Applications and Technical Data W A T L O W The Watlow FIREROD not only set the industry standard for cartridge heaters, it continues making improvements in construction and design. Among those improvements is the metric FIREROD, a variation

More information

GelCap SL. GelCap SL splice cover kits quickly and con-veniently insulate, seal, and protect stub splice connections up to 1000 volts.

GelCap SL. GelCap SL splice cover kits quickly and con-veniently insulate, seal, and protect stub splice connections up to 1000 volts. Cold-Applied Splices GelCap SL Stub splice cover kit with connector for use with street lighting (1000 V) 34 Tyco Electronics GelCap SL splice cover kits provide quick installation, dependable performance,

More information

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS PLEASE READ COMPLETE INSTRUCTIONS BEFORE YOU BEGIN LEAVE INSTALLATION INSTRUCTIONS AND USER'S GUIDE WITH OWNER ALL ELECTRIC WIRING AND PLUMBING MUST BE DONE

More information

UHIR Series. Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater. Owner s Manual

UHIR Series. Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater. Owner s Manual UHIR Series Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater Owner s Manual This manual covers installation, maintenance and repair parts. Read carefully before attempting to

More information

Cartridge Heaters. Components. Application Guidelines

Cartridge Heaters. Components. Application Guidelines Application Guidelines Up to 1.297" Dia. Up to 60" Lengths Up to 11,500 Watts 120 and 240 Volt Up to 1400 F Max. Working Temp. Modification Available to Fit Custom Applications Type CIR cartridge heaters

More information

... with Knowledge Solutions Lightning Protection Standards

... with Knowledge Solutions Lightning Protection Standards Lightning Protection Standards Richard Bouchard Employed With UL for 24 Years Technical Advisor for UL s Lightning Protection Services Member of NFPA 780 Technical Panel Certification for Residential Building

More information

SPECIFICATION DELETED SECTION CENTRIFUGAL HVAC FANS

SPECIFICATION DELETED SECTION CENTRIFUGAL HVAC FANS SECTION 23 34 16 CENTRIFUGAL HVAC FANS PART 1 - GENERAL 1.01 RELATED DOCUMENT A. Drawings and general provisions of the contract, including General and Special Conditions and Division 01 Specification

More information

SECTION DOMESTIC WATER HEATERS

SECTION DOMESTIC WATER HEATERS SECTION 223500 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to

More information

Electrical Protection of CSST Gas Piping Systems. Bob Torbin, PE Omega Flex, Inc.

Electrical Protection of CSST Gas Piping Systems. Bob Torbin, PE Omega Flex, Inc. Electrical Protection of CSST Gas Piping Systems Bob Torbin, PE Omega Flex, Inc. Standard Yellow Arc-Resistant Black CSST Product Standard National Standard ANSI LC-1 Performance-based standard Listed

More information

UNIQUE USER FRIENDLY MICROMETER STYLE ADJUSTMENT

UNIQUE USER FRIENDLY MICROMETER STYLE ADJUSTMENT The series hose crimper with Micrometer Style Adjustment and 80 ton cylinder has the capacity to crimp hoses up to 1-¼" 4 wire (with standard dies) and up to 1-¼" 6 wire and 2" 4 wire (with larger dies).

More information

SECTION ROTARY-SCREW WATER CHILLERS

SECTION ROTARY-SCREW WATER CHILLERS PART 1 GENERAL 1.01 SECTION INCLUDES A. Factory-assembled packaged chiller. B. Charge of refrigerant and oil. C. Controls and control connections. D. Chilled water connections. E. Electrical power connections.

More information

Section 8: Switchgear Connections (Straight & Elbows)

Section 8: Switchgear Connections (Straight & Elbows) 8: Switchgear Connections (Straight & Elbows) HEAT SHRINKABLE RSRB Inline and Right Angle Bushing Boots 126 PUSH ON ELBOWS RCAB-41 Elastomeric Flexible Bushing Boot - up to 17.5kV 127 RCAB-51 Inline Cold

More information

LP30 High Integrity Low Level Alarm Probe Installation and Maintenance Instructions

LP30 High Integrity Low Level Alarm Probe Installation and Maintenance Instructions 4024750/9 IM-P402-44 AB Issue 9 LP30 High Integrity Low Level Alarm Probe Installation and Maintenance Instructions 1 General safety information 2 General product information 3 Installation 4 Wiring 5

More information

Electrical Tech Note 107

Electrical Tech Note 107 Electrical Tech Note 107 Biosystems & Agricultural Engineering Department Michigan State University Understanding the Construction Code Rules, Part 8 1 Based on the 2014 NEC and the 2015 MRC The State

More information

Hydraulic Crimper 05

Hydraulic Crimper 05 Hydraulic Crimper Hydraulic Tools As well as retaining most of the information from the last issue of the catalogue, we have added a large section on new products of interest to our industry. COMPRESSION

More information

Lightning Warning System: LWS MK-II. User's Guide. KOREA EMI Technologies Co.,Ltd , Jangam-ri, Majang-myeon, Icheon-si, Gyeonggi-do, Korea

Lightning Warning System: LWS MK-II. User's Guide. KOREA EMI Technologies Co.,Ltd , Jangam-ri, Majang-myeon, Icheon-si, Gyeonggi-do, Korea User's Guide CONTENTS FEATURES WHAT YOU NEED TO GET STARTED INSTALLATION DETAILS Installing the Antenna Installing the External Alert Siren The main console OPERATING PROCEDURE Power On Routine Push Buttons

More information

SECTION AUTOMATIC TRANSFER SWITCHES

SECTION AUTOMATIC TRANSFER SWITCHES PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 36 23 SPEC WRITER NOTE: Use this section only for NCA projects. Delete between //--// if not applicable to project. Also, delete any other item or paragraph

More information

MDX² INSTALLATION MANUAL

MDX² INSTALLATION MANUAL ANTI-ENTRAPMENT DEBRIS DRAIN MDX² INSTALLATION MANUAL CONCRETE POOLS SUBMERGED SUCTION OUTLET FOR MULTIPLE DRAIN USE FOR USE ON FLOOR SEE SPECIAL INSTRUCTIONS FOR CALIFORNIA AND FLORIDA ON PAGES 4 AND

More information

INSTALLATION INSTRUCTIONS FOR 7330C740 FLUSH MOUNT CEILING ASSEMBLY

INSTALLATION INSTRUCTIONS FOR 7330C740 FLUSH MOUNT CEILING ASSEMBLY INSTALLATION INSTRUCTIONS FOR 7330C740 FLUSH MOUNT CEILING ASSEMBLY TABLE OF CONTENTS Warnings...3 Package Contents...3 General Information...3 Supply Ducting And Registers...3 Routing 115 VAC Wiring...5

More information

Installation Instructions

Installation Instructions Installation Instructions For the 18" Built-In Dishwasher Sears, Roebuck and Co. Sears Canada, Inc. Hoffman Estates, IL 60179 U.S.A. Toronto, Ontario, Canada M5B 2B8 154435201 Before You Begin DO NOT INSTALL

More information

INSTRUCTION MANUAL INSTRUCTION MANUAL

INSTRUCTION MANUAL INSTRUCTION MANUAL INSTRUCTION MANUAL GATOR EK628 Battery-powered Crimping Tool Serialnummer Read and understand all of the instructions and safety information in this manual before operating or servicing this tool. 52023597

More information

HKL1232 Hydraulic Crimping Tool

HKL1232 Hydraulic Crimping Tool INSTRUCTION MANUAL Español... 9 Français... 17 HKL1232 Hydraulic Crimping Tool Read and understand all of the instructions and safety information in this manual before operating or servicing this tool.

More information

Side Entry Insulation Damage Repair Sleeve (SEIDRS) Raychem Devices Products

Side Entry Insulation Damage Repair Sleeve (SEIDRS) Raychem Devices Products 1.0 Scope This specification covers the design, performance and qualification requirements for Raychem Side Entry Insulation Damage Repair Sleeve. 1.1 Description. Raychem SEIDRS covered by this specification

More information

EXPRESSION OF INTEREST (EOI) FOR. Fire Fighting System (FFS)

EXPRESSION OF INTEREST (EOI) FOR. Fire Fighting System (FFS) EXPRESSION OF INTEREST (EOI) FOR Fire Fighting System (FFS) KWtE-03-PR-EO-ACC-0 Rev01 11 Version: Date: Prepared by: Approved: 01 7/11/18 VMC AMN Page 1 OF 5 1 Project overview ACCIONA s Engineering, Procuring

More information

Residential Flush Horizontal Side-Wall Sprinkler Model HF-RES,K=4.2 (SIN / SS4423) (PTFE gasketed orifice seal design)

Residential Flush Horizontal Side-Wall Sprinkler Model HF-RES,K=4.2 (SIN / SS4423) (PTFE gasketed orifice seal design) Page:1 of 5 Residential Flush Horizontal Side-Wall Sprinkler Model HF-RES,K=4.2 (SIN / SS4423) (PTFE gasketed orifice seal design) General Description The Model HF-RES Residential Flush Horizontal Side-Wall

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS KitchenAid. BUILT-IN DISHWASHER KD-20 SERIES INSTALLATION INSTRUCTIONS MR. INSTALLER: FINAL CHECK LIST PLACEMENT OF DISHWASHER 0 1. Properly positioned-level, aligned and square with cabinet opening. 0

More information

Installation Instructions. (Applicable to all front door models)

Installation Instructions. (Applicable to all front door models) COOL CELL Passive Temperature Regulating Battery Enclosures Installation Instructions (Applicable to all front door models) CONTENTS 1. Safety Instructions 2. General Information 3. Cool Cell Description

More information

391 WEST WATER STREET TAUNTON, MA P: F:

391 WEST WATER STREET TAUNTON, MA P: F: 391 WEST WATER STREET TAUNTON, MA 02780 WWW.QUICK-SLING.COM INFO@QUICK-SLING.COM P: 1.800.699.0453 F: 1.800.699.0423 QUICK-SLING MINI-SPLIT STANDS QSMS1200 QSMS1201 QSMS1800 QSMS1801 QSMS2400 QSMS2401

More information

The most advanced Supply Box System from Oatey - the choice of plumbing professionals.

The most advanced Supply Box System from Oatey - the choice of plumbing professionals. TM INFINITE SOLUTIONS The most advanced Supply Box System from Oatey - the choice of plumbing professionals. UNIVERSAL SINGLE BOX PLATFORM SNAP-LOCK DESIGN INSTALLATION VERSATILITY Oatey 2017 Oatey is

More information

RK12ID Remote Dieless Crimping Tool

RK12ID Remote Dieless Crimping Tool INSTRUCTION MANUAL Serial Number RK12ID Remote Dieless Crimping Tool Read and understand all of the instructions and safety information in this manual before operating or servicing this tool. Register

More information

TECHNICAL INSTRUCTIONS

TECHNICAL INSTRUCTIONS TECHNICAL INSTRUCTIONS 24-Month Maintenance Kit P/N 58025-06 For BMK2.0LN Boilers Description of Document: This TID provides the procedures to perform recommended 24-Month maintenance on the following

More information

150T Electric Shop Press

150T Electric Shop Press 150T Electric Shop Press Operation Manual 1 Important Information 1.1 Safety Information 1.1.1 Hazard Symbols Used in the Manuals This manual includes the hazard symbols defined below when the operations

More information

BUTLER COUNTY RURAL ELECTRIC COOPERATIVE ALLISON, IOWA

BUTLER COUNTY RURAL ELECTRIC COOPERATIVE ALLISON, IOWA SERVICE AND METER-RELATED DOCUMENTS BUTLER COUNTY RURAL ELECTRIC COOPERATIVE ALLISON, IOWA TABLE OF CONTENTS Document Page(s) CT & PT Cabinet Rated Overhead/Underground 2-3 Self-Contained Meter Service

More information

FM Munters Drive. Instruction Manual. Munters Drive * Motor Replacement Kit. Motor Replacement Kit for AX and VX Fans

FM Munters Drive. Instruction Manual. Munters Drive * Motor Replacement Kit. Motor Replacement Kit for AX and VX Fans Instruction Manual FM Munters Drive * Motor Replacement Kit for AX and VX Fans *Patents Pending FM Munters Drive Motor Replacement Kit Models: FM1136H FM1136L FM1236H FM1236L Munters Corporation, August

More information

ENERGY /// MINING SOLUTIONS MINING SOLUTIONS RUGGEDIZED HIGH PERFORMANCE PRODUCTS

ENERGY /// MINING SOLUTIONS MINING SOLUTIONS RUGGEDIZED HIGH PERFORMANCE PRODUCTS ENERGY /// MINING SOLUTIONS MINING SOLUTIONS RUGGEDIZED HIGH PERFORMANCE PRODUCTS TE Energy offers a wide range of reliable and cost-effective products for the electrical power industry. Our position as

More information

UNIQUE USER FRIENDLY MICROMETER STYLE ADJUSTMENT

UNIQUE USER FRIENDLY MICROMETER STYLE ADJUSTMENT The series hose crimper with Micrometer Style Adjustment and 62 tons of crimping force has the capability to crimp hoses up -¼" -2 wire, -¼" 4 wire, and " 6 wire. UNIQUE USER FRIENDLY MICROMETER STYLE

More information

Ecodrain V1000. Selection and Installation Guide for Residential Applications TM MC TM

Ecodrain V1000. Selection and Installation Guide for Residential Applications TM MC TM Ecodrain V1000 Selection and Installation Guide for Residential Applications TM MC TM PRECISION ENGINEERING LEADS TO HIGH PERFORMANCE 2 3 WHAT S INCLUDED IN THE BOX Lead Free Brass Cast Manifold, with

More information

JOE SCHROEDER Apprentice Electrician

JOE SCHROEDER Apprentice Electrician JOE SCHROEDER Apprentice Electrician From battery to ratchet, if it needs to be cut or crimped, Greenlee s got the tool. A Greenlee exclusive the Gator-Plus battery-powered 4-ton crimping tool brings tons

More information

Transportation. Distribution

Transportation. Distribution Distribution Transportation Busbar Shielded Systems type: Cast Resin Low Voltage The shielded busbar system, ISOBUSBAR, type IS isolated in polyester or epoxy resin, have been specifically developed for

More information

INSTALLATION INSTRUCTIONS FOR 7330*5511 OR 7330*5512 MOUNTING KIT 7330B751 CONTROL BOX KIT (12 VDC COOL ONLY)

INSTALLATION INSTRUCTIONS FOR 7330*5511 OR 7330*5512 MOUNTING KIT 7330B751 CONTROL BOX KIT (12 VDC COOL ONLY) INSTALLATION INSTRUCTIONS FOR 7330*5511 OR 7330*5512 MOUNTING KIT 7330B751 CONTROL BOX KIT (12 VDC COOL ONLY) 7530B750 CONTROL BOX KIT (24 VAC COOL ONLY) 8330A751 ZONE CONTROL KIT (12 VDC COOL ONLY) 8530B751

More information

SECTION P01 LIGHTING AND APPLIANCE PANELBOARDS - A-SERIES

SECTION P01 LIGHTING AND APPLIANCE PANELBOARDS - A-SERIES PART 1 GENERAL A. The requirements of the Contract, Division 1, and Division 16 apply to work in this Section. 1.01 SECTION INCLUDES A. Lighting and appliance panelboards 1.02 RELATED SECTIONS A. 16475,

More information

General System Layout Sketch

General System Layout Sketch General System Layout Sketch EZ-37 Solar Panels PV panel Glycol Fill Valve Expansion Tank ` 1 Introduction This document describes how to install a Heliatos GH type solar water heating system. These systems

More information

Roof Mounting System. Installation Manual. Standard (XRS) and Light (XRL) Rails with Integrated Grounding *ETL Listed Per UL Edition v1.

Roof Mounting System. Installation Manual. Standard (XRS) and Light (XRL) Rails with Integrated Grounding *ETL Listed Per UL Edition v1. Roof Mounting System Standard (XRS) and Light (XRL) *ETL Listed Per UL2703 2013 Edition v1.1 A complete manual for the installation of IronRidge s rail systems with integrated grounding. This Installation

More information

Owners Manual. SM-HP A SM-HP8-10 Meter. Manual D

Owners Manual. SM-HP A SM-HP8-10 Meter. Manual D DuraCore TM Fan Owners Manual SM-HP8-64-360A SM-HP8-10 Meter Manual 9-1473D 1 4 5 7 8 9 6 MONEL HARDWARE 7 8 9 STAINLESS HARDWARE 00 FAN BLADE FAN HUB 3 Fan Components Marley Order No. Trial Pitch Angle

More information

B. Product Data: Provide manufacturers catalogue information. Indicate valve data and ratings.

B. Product Data: Provide manufacturers catalogue information. Indicate valve data and ratings. DIVISION 21 21 05 00 COMMON WORK RESULTS FOR FIRE SUPPRESSION PART 1 GENERAL 1.1 SECTION INCLUDES A. Pipe, fittings, sleeves, escutcheons, seals, and connections for sprinkler systems. 1.2 RELATED REQUIREMENTS

More information

Reliable solutions for electrified railway systems

Reliable solutions for electrified railway systems Reliable solutions for electrified railway systems 1 2 3 Insulation Enhancement System Insulation Enhancement System 1. Raychem MVLC: (Medium Voltage Line Cover) Provides insulation for catenary, droppers

More information

SECTION GENERAL-SERVICE COMPRESSED-AIR SYSTEMS

SECTION GENERAL-SERVICE COMPRESSED-AIR SYSTEMS PART 1 GENERAL 1.01 SECTION INCLUDES A. Pipe and Pipe Fittings. B. Air compressor. C. Air receiver and accessories. D. Aftercooler. E. Refrigerated air dryer. F. Pressure reducing station. 1.02 RELATED

More information

DIVISION 15 MECHANICAL

DIVISION 15 MECHANICAL DIVISION 15 MECHANICAL A. GENERAL DESIGN CONDITIONS 1. Design occupied spaces to maintain 72 F and a space dew point temperature not to exceed 55 F. 2. Design classroom and office space buildings with

More information

Hydraulic Crimping Head, PN

Hydraulic Crimping Head, PN Hydraulic Crimping Head, PN 1673672-1 Instruction Sheet 408-8910 14 JUL 17 Rev C PROPER USE GUIDELINES Cumulative trauma disorders can result from the prolonged use of manually powered hand tools. Hand

More information

The most advanced Supply Box System from Oatey - the choice of plumbing professionals.

The most advanced Supply Box System from Oatey - the choice of plumbing professionals. T MT M INFINITE SOLUTIONS The most advanced Supply Box System from Oatey - the choice of plumbing professionals. UNIVERSAL SINGLE BOX PLATFORM SNAP-LOCK DESIGN INSTALLATION VERSATILITY Oatey 2017 Oatey

More information

GESTRA Steam Systems ER 50-1, ER Installation Instructions Level electrode

GESTRA Steam Systems ER 50-1, ER Installation Instructions Level electrode GESTRA Steam Systems ER 50-1 ER 56-1 Installation Instructions 818781-00 Level electrode ER 50-1, ER 56-1 Contents Important Notes Page Usage for the intended purpose...4 Safety note...4 Danger...4 Attention...4

More information

PHILADELPHIA REGIONAL PORT AUTHORITY VOLUME 2 SPECIFICATIONS FOR VEHICLE PROCESSING FACILITY NAVAL BUSINESS CENTER PHILADELPHIA PA.

PHILADELPHIA REGIONAL PORT AUTHORITY VOLUME 2 SPECIFICATIONS FOR VEHICLE PROCESSING FACILITY NAVAL BUSINESS CENTER PHILADELPHIA PA. PHILADELPHIA REGIONAL PORT AUTHORITY VOLUME 2 SPECIFICATIONS FOR VEHICLE PROCESSING FACILITY NAVAL BUSINESS CENTER PHILADELPHIA PA Prepared By STV Incorporated 205 West Welsh Drive Douglassville, PA 19518

More information

GLOBAL LIFT CORP. Owner s Manual. Home Series

GLOBAL LIFT CORP. Owner s Manual. Home Series GLOBAL LIFT CORP Owner s Manual Home Series 684 N Port Crescent Rd Suite C Bad Axe, MI 48413 Toll Free: 866-712-0606 Fax: 989-269-5902 www.globalliftcorp.com Page 1 HOME SERIES POOL LIFTS TABLE OF CONTENTS

More information

INSTALLATION AND COMMISSIONING MANUAL. Neos 100S Integra 20X, 30S, 35X, 40X, 50X

INSTALLATION AND COMMISSIONING MANUAL. Neos 100S Integra 20X, 30S, 35X, 40X, 50X Installation Truck Refrigeration & Commissioning Manual: INSTALLATION AND COMMISSIONING MANUAL for Neos 100S Integra 20X, 30S, 35X, 40X, 50X Direct Drive Refrigeration Units 2017 Carrier Corporation Printed

More information

SECTION 2 NEC REFERENCES SECTION 1 LOW-VOLTAGE AND POWER- LIMITED SYSTEMS...1. CHAPTER 1 GENERAL Introduction...35

SECTION 2 NEC REFERENCES SECTION 1 LOW-VOLTAGE AND POWER- LIMITED SYSTEMS...1. CHAPTER 1 GENERAL Introduction...35 SECTION 1 LOW-VOLTAGE AND POWER- LIMITED SYSTEMS...1 Overview of Low-Voltage and Power-Limited Systems...3 Chapter 4 Equipment for General Use...3 Chapter 5 Special Occupancies...3 Chapter 6 Special Equipment...4

More information

ultra quiet fan USER MANUAL INSTALLATION OPERATION MAINTENANCE

ultra quiet fan USER MANUAL INSTALLATION OPERATION MAINTENANCE USER MANUAL ultra quiet fan INSTALLATION OPERATION MAINTENANCE Z0414808 rev A ISSUED 02/2014 READ AND UNDERSTAND THIS MANUAL PRIOR TO OPERATING OR SERVICING THIS PRODUCT. safety and handling Safety Warning

More information

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes). Guide Specifications PART 1 GENERAL 1.01 SYSTEM DESCRIPTION Microprocessor controlled, air-cooled liquid chiller utilizing scroll compressors, low sound fans, hydronic pump system and optional fluid storage

More information