Commercial Heating Domestic Heating

Size: px
Start display at page:

Download "Commercial Heating Domestic Heating"

Transcription

1 25 twenty fifth anniversary twenty fifth anniversary Commercial Heating Domestic Heating GUARANTEE FREE 5 YEARS parts & labour on all products Manufactured in the UK #ThinkSmiths

2 Contents Contents Solutions for domestic & commercial applications p 4-5 Summary of product range - Commercial applications p Commercial fan convectors p 8-29 Summary of product range - Domestic applications p Domestic fan convectors p Flame-effect fan convectors p Natural convectors (perimeter heating) p Plinth Heaters - hydronic p Plinth Heaters - electric p 45 Glossary p

3 If you require energy efficiency and versatility in your heating, the Smith s range of fan convectors is the ideal solution. Introduction Why choose Smith s? For over twenty-five years, Smith s EP UK has been manufacturing and providing an extensive range of commercial and domestic heating and water solutions from our head office in the UK. Part of the global family-owned US-based business, the Swan Group, Smith s works closely with architects, consultants, heating contractors and installers to deliver high quality fan convectors with industry-leading warranties on time, with an aftercare and technical support service that is second to none. We take an active, innovative approach to new product development and creating bespoke heating products to fulfil the creative requirements of a competitive and demanding customer base that spans the UK, Northern Europe and the US. We believe it s essential to be flexible in our partnerships, while remaining uncompromising on the high quality and care that goes into every product in our range. Smith s is an outward-looking, growing business and we are forging relationships with like-minded manufacturers across Europe to ensure that we can provide additional new and essential heating or water products in areas where we do not specialise and where our partners excel. Our latest brochure showcases our principal commercial and domestic products, detailing the range of fan convectors that we provide. At the same time, we have the ability and the will to work alongside clients at any point in the construction process, and collaborate to develop specific solutions for any and every need. We take great pride and go to great lengths to leave our customers not only satisfied but coming back again and again for heating solutions that are perfect for your project, each and every time. Gary Haynes MBA, B.Eng.(Hons) Managing Director #ThinkSmiths 3

4 Solutions for commercial and domestic applications Solutions for domestic & commercial applications Standard heating systems How fan convectors work Smith s fan and flame-effect fan convectors work efficiently and effectively with all types of wet central heating systems, including gas, oil, electric, biomass or LPG boilers. They also require an electrical connection to run the fan. Hot water from the central heating system passes through the heat exchanger, transferring its heat to the aluminium fins. Cooler air is drawn in by the fan and heated as it passes over the heat exchanger, before being expelled gently back into the room. This gives a more even temperature spread and heats rooms in much less time than a traditional panel radiator. Each Smith s fan convector includes a low temperature cut-out system, preventing the product from operating until the system water temperature reaches a pre-set level. Electric versions connect to a standard electrical system via a fused spur. Fan convectors use either AC or EC motor technology to drive the fan. AC motors typically provides the end user with a number of fixed speeds whilst EC technology offers infinite control over the fan speed and heat output. At home with Smith s fan convectors For a trained heating engineer, installing our fan convectors is simple because they use the same pipe work, fitting procedures and heat loss calculations as radiators. We also provide installation guides for all our products via our website. With the heat output switch left on either normal or boost position, they will come on and off automatically with the central heating system. Each model includes a low temperature cut-out, which prevents the product operating until the water temperature reaches a pre-set temperature. They can be used alone or paired with radiators and can be sited almost anywhere to suit the size and style of the building. Place them low on walls, above doorways or high up on other walls for safety or space considerations. Our renowned Space Saver is designed to be sited in a plinth under a kitchen base unit to create more storage space, worktop surface area or room for additional white goods. For those concerned about running costs, fan convectors use a very small amount of electricity to run the fan and/or bulb (flameeffect fan convectors only). Based on an annual usage of 1300 hours with electricity charged at 15p per kwh, we calculate electricity costs to be less than 5 per year for a fan convector and less than 10 per year for flame-effect fan convectors. Natural Convectors (Perimeter Heating) Requiring connection to a wet central heating system, hot water passes through the heat exchanger, transferring its heat to the aluminium fins. The natural movement of air gently circulates over the heat exchanger, is warmed and evenly distributed around the room. 4 A typical central heating system combining condensing boiler, radiator, two EcoPowerad fan convectors and a Space Saver plinth heater.

5 Low temperature heating systems Working with heat pumps Renewable technology grows apace, with ground and air source heat pumps beginning to become a viable alternative to boilers as the principal heat generator in homes around the UK. Inherent in the heat pump s design is that the smaller the temperature difference between the heat source pump (air or ground) and the heat sink/emitter (under-floor heating, fan convector, radiator), the higher the energy efficiency of that heat pump. This higher efficiency means lower fuel bills and greater carbon savings for that home. Fan convectors can work very effectively at system temperatures as low as 40 C. This allows your chosen heat pump to work close to its maximum levels of efficiency, which means it will reduce the user s energy costs and energy consumption in the way that it was intended. By contrast, a standard radiator is designed to be efficient at higher temperatures, 45 C and above, which automatically reduces the heat pump s efficiency by more than 10%. In addition the size of the radiator has to be increased significantly to cope with the lower system temperatures. Solutions for commercial and domestic applications Comparable fan convector v radiator on a low temperature system Height Width Depth Weight Fan convector 400mm 1210mm 95mm 14kg Radiator 600mm 1800mm 180mm 63kg SAP* calculation comparison An example SAP calculation shows that using a combination of an air source heat pump with a fan convector in a new build or existing property, should show a reduction of at least 12% in running costs (and carbon usage) when compared with a radiator and air source heat pump, and that using a fan convector in this way achieves close to the efficiencies obtained by installing underfloor heating. *The Standard Assessment Procedure (SAP) is the UK Government's recommended method system for measuring the energy rating of residential dwellings. 5

6 Summary of product ranges - Commercial applications Summary of product ranges - Commercial applications Caspian UV EC and AC motors p8-11 One heating solution for a variety of applications, suitable for high, low or ceiling-mounted installation. Incorporating EC and AC motor technology, the UV delivers heat quickly, efficiently and effectively. Heat outputs up to 19.2kW (65500 Btu/h). Caspian FF EC and AC motors p8-11 Probably the most popular style of commercial fan convector in the UK, with EC technology and heat outputs up to 19.2kW (65500 Btu/h). Caspian EXT EC and AC motors p8-11 An extended version of FF model. Heat outputs up to 19.2kW (65500 Btu/h). Caspian UVC EC and AC motors p12-17 Heating only fan convector/fan coil product capable of being concealed on or behind walls at high or low level, within ceiling voids and on or below floors. Incorporating EC motor technology the Universal delivers heat quickly, efficiently and effectively. Heat outputs up to 14.5kW (49200 Btu/h). Caspian LST EC motors p18-19 The Caspian LST is suitable for a range of low level installation projects in any NHS Estates premises including hospitals, clinics, surgeries and other health care premises. Caspian High AC motors p20-22 Designed for unobtrusive fixing at high level, Caspian s rapid response heating is ideal for heating the large areas of schools, churches, care homes, libraries, offices, and hospitals. Heat outputs up to 14.4kW (49200 Btu/h). Caspian Low AC motors p20-22 A floor or wall-mounted fan convector developed for a diversity of applications in commercial installations. Available in a range of eight models and a low surface temperature casing for complete safety. Heat outputs up to 14.4kW (49200 Btu/h). Sterling Electric heaters p23 Designed for unobtrusive fixing at high level and ideal for retail units, offices and nurseries. Heat outputs up to 3.0kW. versions available. Caspian Skyline EC and AC motors p24-25 Caspian Skyline fan convector fits sleekly into a 600mm x 600mm ceiling tile, providing easy access for both installation and maintenance. Using current EC technology, it delivers discreet heating in schools, retail or food units and plumbs easily into the central heating system. Heat outputs up to 5.1kW(17500Btu/h). Skyline AC motors p26 The ceiling-mounted Skyline provides the perfect solution to heating larger commercial spaces. Units install simply into a standard 600mm x 600mm ceiling tile space. There is also an allelectric model available. Heat outputs up to 5.5kW (18800 Btu/h). Skyline E 4kW Electric heaters p27 Like its hydronic sibling, this is designed for unobtrusive fixing at high level and is ideal for retail units, showrooms and nurseries. Allows maximum use of wall space with a safe, high-level heat source. Heat outputs up to 4.0kW. versions available. Ecovector /Sterling High AC motors p28-29 Designed for unobtrusive fixing at high level and ideal for retail units, offices and nurseries. Both hydronic and electric versions available plus a low voltage model for bathrooms. Heat outputs up to 4.0 kw (13500 Btu/h). 6

7 Applications chart Domestic Room Best 444 Better 44 Good 4 Kitchen/Utility Room Space Saver Plinth Ecovector High Ecovector Low Sterling High Eco-Powerad Low Bathroom/En-suite Space Saver Plinth Ecovector High Sterling High Cloakroom Ecovector High Sureline Ecovector Low Sterling High Eco-Powerad Low Hall Ecovector Vertical Ecovector Low Sureline Eco-Powerad Low Landing Ecovector Low Ecovector Vertical Eco-Powerad Low Living Room/Dining Room Ecovector Low Ecovector Vertical Spacemaker Recessed Eco-Powerad Low Fireplace Hydroflame Conservatory Ecovector High Ecovector Vertical Sterling High Bedroom Ecovector Low Sureline Ecovector Vertical Eco-Powerad Low Home Office/Study Ecovector High Ecovector Low Ecovector Vertical Sterling High Eco-Powerad Low Commercial Room Best 444 Better 44 Good 4 Showroom Caspian UV/UVC/FF Skyline Ceiling High Caspian Low Caspian High Ecovector Sureline Caspian Skyline Shop Caspian UV/UVC/FF Skyline Ceiling Ecovector Vertical Caspian High Ecovector High Caspian Skyline Sterling High Entrance Hall/Corridor Caspian UV/UVC/FF Skyline Ceiling Ecovector Vertical Caspian High Ecovector High Sureline Sterling High Spacemaker Recessed Reception Ecovector Low Ecovector Vertical Ecovector High Eco-Powerad Low Sureline Sterling High Caspian High Waiting Room Caspian UV/UVC/FF Skyline Ceiling Ecovector Vertical Caspian High Ecovector High Caspian Low Sterling High Meeting Room/Hall/Club Caspian UV/UVC/FF Skyline Ceiling Ecovector Vertical Caspian High Ecovector High Caspian Skyline Sterling High Changing Room Caspian UV/UVC/FF Skyline Ceiling Ecovector Vertical Caspian High Ecovector High Caspian Skyline Sterling High Public House Caspian UV/UVC/FF Skyline Ceiling Ecovector Vertical Caspian High Ecovector High Caspian Skyline Sterling High Place of Worship Caspian UV/UVC/FF/EXT Ecovector Low Ecovector Vertical Caspian High Eco-Powerad Low Sureline Caspian Low School, Nursery Caspian UV/UVC/FF/EXT Skyline Ceiling Ecovector High Caspian LST/LL/HL Caspian High Sterling High Caspian Skyline Sterling High Care Home, Hospital Caspian UV/UVC/FF Skyline Ceiling Ecovector High Caspian Universal LST Caspian High Sterling High Caspian Skyline Sterling High Sureline Library Caspian UV/UVC/FF Skyline Ceiling Ecovector Low Caspian High Ecovector High Eco-Powerad Low Caspian Skyline Sterling High Summary of product ranges - Commercial applications 7

8 1. Commercial fan convectors 1. Commercial fan convectors Caspian Caspian by Smith s is a range of fan convectors suitable for all kinds of commercial applications, from churches to office developments, with the ability rapidly heat large areas with much greater efficiency than other heat emitters. Caspian fan convectors are both a practical and high quality heating solution for any commercial project. Incorporating the latest EC motor technology, which can result in running-cost savings as high as 80%, and with variable speed control as standard, the Caspian delivers heat quickly and quietly. AC motor models are available on request. Like all Smith s fan convectors, Caspians are compatible with most types of wet central heating systems, functioning equally efficiently with conventional boilers, biomass technology or ground or air source heat pumps. Caspian UV Caspian FF Caspian EXT Caspian UV, FF and EXT Motor EC or AC EC motors are BMS compliant Finish Casing: zinc-coated steel 1.2mm. Polyester powdercoated: white RAL 9010 Available to special order in any colour Available with anti-microbial or anti-bacterial paint Filter Class G3, 100% polyester, non-washable Installation Suitable for two-pipe central heating systems Maximum installation height for high or ceiling mounting - 4m to underside Pipework access holes on the rear and underside Key operated front access panels Bleed valve accessible on removal of front casing Unit must be earthed Commissioning Check water is hot enough to activate the low temperature cut-out thermostat Controls Variable heat output controller (mounted within the product) Accessories External control harness (for up to 4 products) Plinth (150mm high) to suit each model, available in black or white Adjustable low temperature cut-out (30 C to 90 C) Wall mounted room thermostat Proportional heat output controller 22mm flexible hoses (pair) See Glossary on page 46 for further information on Accessories 8 Principal Accessories External control harness Adjustable low temperature cut-out Plinth Wall mounted room thermostat Proportional heat output controller 22mm flexible hoses

9 1. Commercial fan convectors Heat Output at 80 Heat Output at 75 Heat Output at 70 Low Medium High Low Medium High Low Medium High (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) Caspian (10900) 4.5 (15500) 5.9 (20000) 2.9 (9900) 4.1 (14000) 5.3 (18100) 2.6 (8800) 3.7 (12500) 4.8 (16200) Caspian (17700) 7.8 (26500) 10.3 (35200) 4.8 (16300) 7.2 (24600) 9.6 (32800) 4.4 (15000) 6.7 (22700) 8.9 (30400) Caspian (22700) 10.7 (36500) 14.5 (49400) 6.1 (20937) 9.6 (32968) 13.2 (45000) 5.6 (19100) 8.7 (29800) 11.9 (40600) Caspian (50500) 15.4 (52500) 16.2 (55300) 13.7 (46700) 14.2 (48500) 15.2 (51900) 12.5 (42700) 13.1 (44700) 14.0 (47800) Caspian (58700) 18.2 (62100) 19.2 (65500) 16.2 (55300) 17.0 (58000) 18.0 (61400) 14.9 (50800) 15.7 (53600) 16.7 (57000) Heat Output at 65 Heat Output at 60 Heat Output at 55 Low Medium High Low Medium High Low Medium High (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) Caspian (7800) 3.2 (11100) 4.2 (14300) 2.0 (6800) 2.8 (9600) 3.6 (12400) 1.7 (5800) 2.4 (8200) 3.1 (10600) Caspian (13500) 6.0 (20400) 8.0 (27300) 3.5 (11900) 5.3 (18000) 7.1 (24200) 3.0 (10400) 4.6 (15800) 6.2 (21100) Caspian (16600) 7.7 (26400) 10.6 (36200) 4.1 (14100) 6.8 (23200) 9.4 (32000) 3.4 (11600) 5.8 (19700) 8.1 (27700) Caspian (38600) 11.9 (40600) 12.8 (43700) 9.9 (33800) 10.8 (36900) 11.6 (39600) 8.8 (30000) 9.7 (33100) 10.4 (35500) Caspian (46400) 14.4 (49100) 15.4 (52500) 12.4 (42300) 13.3 (45400) 14.1 (48100) 11.3 (38600) 12.0 (40900) 12.8 (43700) 1. Commercial fan convectors Heat Output at 50 Heat Output at 45 Heat Output at 40 Low Medium High Low Medium High Low Medium High (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) Caspian (4800) 2.0 (6800) 2.5 (8700) 1.1 (3800) 1.5 (5100) 1.9 (6300) 0.8 (2700) 1.0 (3400) 1.2 (4000) Caspian (8800) 3.9 (13400) 5.3 (18000) 2.0 (7000) 3.1 (10500) 4.1 (14000) 1.5 (5100) 2.2 (7500) 2.9 (10000) Caspian (9000) 4.8 (16300) 6.9 (23500) 2.0 (6700) 3.7 (12600) 5.4 (18400) 1.3 (4400) 2.6 (8900) 3.9 (13400) Caspian (25600) 8.2 (28000) 9.0 (30700) 6.2 (21200) 6.9 (23500) 7.5 (25600) 4.8 (16400) 5.4 (18400) 6.1 (21800) Caspian (33400) 10.5 (35800) 11.2 (38200) 8.4 (28700) 9.1 (31100) 9.4 (32100) 6.6 (22500) 7.3 (24900) 7.8 (26600) Heat Output testing based on BS EN442 using mean water temperature, 18 C entering air temperature, 10 deg temperature drop. Total Power Consumption Flow & Return Mains Flexible Isolation Fused Low Medium High Water Capacity Connections Cable Transformer Hoses Valves Spur (Watts) (Watts) (Watts) (Litres) Caspian 60 22mm n/a n/a n/a n/a 3A Caspian 90 22mm n/a n/a n/a n/a 3A Caspian mm n/a n/a n/a n/a 3A Caspian mm n/a n/a n/a n/a 3A Caspian mm n/a n/a n/a n/a 3A Sound Levels High Medium Low Casting Fan (dba) (dba) (dba) Colour Only Caspian White n/a Caspian White n/a Caspian White n/a Caspian White n/a Caspian White n/a Correction factors Mean Water Temperature C EATºC 80 to Temperature Drop C Factor Measured at 3m in front of floor mounted model. Packed Weight Packed Weight Packed Weight Caspian UV 60 23KG Caspian FF 60 24KG Caspian EXT 60 30KG Caspian UV 90 36KG Caspian FF 90 39KG Caspian EXT 90 49KG Caspian UV KG Caspian FF KG Caspian EXT KG Caspian UV KG Caspian FF KG Caspian EXT KG Caspian UV KG Caspian FF KG Caspian EXT KG 9

10 1. Commercial fan convectors 1. Commercial fan convectors Caspian Our active, innovative approach to new product development gives us the ability to create bespoke heating products for our clients and partners, developing specific one-off fan convector solutions for the demands of your project, should you require. The Caspian range of fan convectors includes the UV, suitable for all locations, the FF, probably the most popular style of commercial fan convector in the UK, and the EXT, an extended FF model. Caspian FF Caspian EXT 10

11 1. Commercial fan convectors The Caspian UV, one heating solution, suitable for high, low or ceiling-mounted applications, you can even turn it upside down. 1. Commercial fan convectors Caspian UV mounted low Caspian UV mounted high Caspian UV ceiling-mounted Caspian diagrams showing different options Caspian UV 11

12 1. Commercial fan convectors 1. Commercial fan convectors Caspian UVC The Caspian UVC fan convector was developed for recessed or concealed heating projects. This is another versatile heating solution from Smith s, suitable for high, low or ceiling concealed installations and the UVC can even be turned upside down. Compatible with all types of wet central heating systems and any commercial or domestic air source heat pump project, the Caspian UVC has four different main accessories. They function together in any combination to create the recessed or concealed heating solution required, depending on the project specification. AC motor models are available on request. The four main accessories (see p14) comprise: spigot inlet/outlets; cranked ducts, 90 for left or right-handed use; a 1m adjustable straight air inlet/outlet duct, which can be used alone or with additional lengths; and an inlet/outlet grille. Listed buildings, including places of worship, hotels and stately homes can benefit from the Caspian UVC 12

13 1. Commercial fan convectors Heat Output at 80 Heat Output at 75 Heat Output at 70 Low Medium High Low Medium High Low Medium High (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) Caspian UVC (10900) 4.5 (15500) 5.9 (20000) 2.9 (9900) 4.1 (14000) 5.3 (18100) 2.6 (8800) 3.7 (12500) 4.8 (16200) Caspian UVC (17700) 7.8 (26500) 10.3 (35200) 4.8 (16300) 7.2 (24600) 9.6 (32800) 4.4 (15000) 6.7 (22700) 8.9 (30400) Caspian UVC (22700) 10.7 (36500) 14.5 (49400) 6.1 (20937) 9.6 (32968) 13.2 (45000) 5.6 (19100) 8.7 (29800) 11.9 (40600) Caspian UVC (50500) 15.4 (52500) 16.2 (55300) 13.7 (46700) 14.2 (48500) 15.2 (51900) 12.5 (42700) 13.1 (44700) 14.0 (47800) Caspian UVC (58700) 18.2 (62100) 19.2 (65500) 16.2 (55300) 17.0 (58000) 18.0 (61400) 14.9 (50800) 15.7 (53600) 16.7 (57000) Heat Output at 65 Heat Output at 60 Heat Output at 55 Low Medium High Low Medium High Low Medium High (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) Caspian UVC (7800) 3.2 (11100) 4.2 (14300) 2.0 (6800) 2.8 (9600) 3.6 (12400) 1.7 (5800) 2.4 (8200) 3.1 (10600) Caspian UVC (13500) 6.0 (20400) 8.0 (27300) 3.5 (11900) 5.3 (18000) 7.1 (24200) 3.0 (10400) 4.6 (15800) 6.2 (21100) Caspian UVC (16600) 7.7 (26400) 10.6 (36200) 4.1 (14100) 6.8 (23200) 9.4 (32000) 3.4 (11600) 5.8 (19700) 8.1 (27700) Caspian UVC (38600) 11.9 (40600) 12.8 (43700) 9.9 (33800) 10.8 (36900) 11.6 (39600) 8.8 (30000) 9.7 (33100) 10.4 (35500) Caspian UVC (46400) 14.4 (49100) 15.4 (52500) 12.4 (42300) 13.3 (45400) 14.1 (48100) 11.3 (38600) 12.0 (40900) 12.8 (43700) 1. Commercial fan convectors Heat Output at 50 Heat Output at 45 Heat Output at 40 Low Medium High Low Medium High Low Medium High (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) Caspian UVC (4800) 2.0 (6800) 2.5 (8700) 1.1 (3800) 1.5 (5100) 1.9 (6300) 0.8 (2700) 1.0 (3400) 1.2 (4000) Caspian UVC (8800) 3.9 (13400) 5.3 (18000) 2.0 (7000) 3.1 (10500) 4.1 (14000) 1.5 (5100) 2.2 (7500) 2.9 (10000) Caspian UVC (9000) 4.8 (16300) 6.9 (23500) 2.0 (6700) 3.7 (12600) 5.4 (18400) 1.3 (4400) 2.6 (8900) 3.9 (13400) Caspian UVC (25600) 8.2 (28000) 9.0 (30700) 6.2 (21200) 6.9 (23500) 7.5 (25600) 4.8 (16400) 5.4 (18400) 6.1 (21800) Caspian UVC (33400) 10.5 (35800) 11.2 (38200) 8.4 (28700) 9.1 (31100) 9.4 (32100) 6.6 (22500) 7.3 (24900) 7.8 (26600) Heat Output testing based on BS EN442 using mean water temperature, 18 C entering air temperature, 10 deg temperature drop. Total Power Consumption Flow & Return Mains Flexible Isolation Fused Low Medium High Water Capacity Connections Cable Transformer Hoses Valves Spur (Watts) (Watts) (Watts) (Litres) Caspian UVC 60 22mm n/a n/a n/a n/a 3A Caspian UVC 90 22mm n/a n/a n/a n/a 3A Caspian UVC mm n/a n/a n/a n/a 3A Caspian UVC mm n/a n/a n/a n/a 3A Caspian UVC mm n/a n/a n/a n/a 3A Sound Levels High Medium Low Casting Fan (dba) (dba) (dba) Colour Only Caspian UVC White n/a Caspian UVC White n/a Caspian UVC White n/a Caspian UVC White n/a Caspian UVC White n/a Correction factors Mean Water Temperature C EATºC 80 to Temperature Drop C Factor Measured at 3m in front of floor mounted model. Caspian UVC 60 Caspian UVC 90 Caspian UVC 120 Caspian UVC 150 Caspian UVC 180 Packed Weight 23KG 36KG 45KG 60KG 78KG 13

14 1. Commercial fan convectors 1. Commercial fan convectors Caspian UVC Principal Accessories Circular spigot airlet/outlet duct 90 cranked air inlet/outlet 1m adjustable straight air inlet/outlet extension duct External control harness Powder-coated steel inlet/outlet grille Anodised aluminium inlet/outlet grille Caspian UVC Motor EC or AC EC motors are BMS compliant Finish Casing: galvanised steel 1.2mm Filter Class G3, 100% polyester, non-washable Installation Suitable for two-pipe central heating systems Unit must be earthed Commissioning Check water is hot enough to activate the low temperature cut-out thermostat Controls Variable heat output controller (mounted within the product) Accessories Adjustable low temperature cut-out (30 C to 90 C) External control harness (for up to four products) Proportional heat output controller 22mm flexible hoses (pair) White powder-coated steel inlet/outlet grille Anodised aluminium air inlet/outlet grille 90 C cranked air inlet/outlet duct 1m adjustable straight air inlet/outlet extension duct Circular spigot air inlet/outlet duct Adjustable low temperature cut-out Proportional heat output controller 22mm flexible hoses See Glossary on page 46 for further information on Accessories 14

15 1. Commercial fan convectors UVC90 A = 818 B = 638 UVC 120 A = 1118 B = PIPE CENTRES 'A' 'B' MAIN UNIT DIMENSIONS MODEL A B UVC UVC UVC UVC UVC ELECTRICAL SUPPLY IN THIS SIDE 1. Commercial fan convectors 70 ADJ. 'B' ELECTRICAL SUPPLY IN THIS SIDE 90 cranked air inlet outlet duct UVC90 A = 641 UVC120 A = º CRANKED DUCT MODEL A UVC UVC UVC UVC UVC 'A' UVC90 A = 640 B = 632 UVC120 A = 940 B = metre straight air inlet outlet extension duct 1 METRE STRAIGHT DUCT 'B' 'A' MODEL A B UVC UVC UVC UVC UVC 'B' UVC90 A = 675 B = 614 Anodised aluminium inlet outlet grille UVC120 A = 'A' Ø B = ALUMINIUM GRILLE MODEL A B UVC UVC UVC UVC UVC Louvre Panel R90 Circular spigot air inlet/outlet duct CIRCULAR SPIGOT DUCT Powder coated steel inlet outlet grille STEEL GRILLE UVC120 A = 961 'A' Ø MODEL A DUCTS UVC UVC UVC UVC UVC MODEL A UVC UVC UVC UVC UVC All dimensions in mm 15

16 1. Commercial fan convectors 1. Commercial fan convectors Caspian UVC Floor mounted application The Caspian UVC can be installed either on or behind walls at high and low level, in ceiling voids and on or under floors. Detailed below are a number of application options than can be achieved with the Caspian UVC and Accessories. If in doubt please contact us. Air outlet Air inlet option Reversible 16

17 1. Commercial fan convectors Suspended with ducts application 1. Commercial fan convectors Suspended with spigots application Air outlet Air inlet option Reversible 17

18 1. Commercial fan convectors 1. Commercial fan convectors Caspian LST The LST solution for all properties under the Registered Homes Act Smith s Caspian LST fan convector fully complies with the NHS Estates Health Guidance Notes, "Safe hot water and surface temperatures" (formally known as DN4) and its operation and compliance has been independently verified by BSRIA. The Caspian LST is suitable for a range of low level installation projects in any NHS Estates premises including hospitals, clinics, surgeries and other health care premises where heat emitters whose maximum surface temperature does not exceed 43 C are required. Incorporating the latest EC motor technology, the three models (120, 90 and 60) are all hydronic and plumb into any wet two-pipe central heating system whether conventional or renewable. The Caspian LST delivers heat quickly, efficiently and effectively and there is also a range of additional controls and accessories available, as required. Caspian LST Heat Output at 80 Heat Output at 75 Heat Output at 70 Low Medium High Low Medium High Low Medium High kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) Caspian LST (3400) 1.6 (5400) 2.2 (7400) 0.9 (3200) 1.4 (4900) 1.9 (6600) 0.8 (2900) 1.3 (4400) 1.7 (5900) Caspian LST (10200) 3.5 (11800) 3.9 (13400) 2.8 (9600) 3.2 (11100) 3.7 (12600) 2.6 (9000) 3.0 (10400) 3.5 (11800) Caspian LST (17000) 5.3 (18300) 5.7 (19500) 4.7 (16000) 5.1 (17300) 5.5 (18600) 4.4 (15100) 4.8 (16400) 5.2 (17700) Caspian LST (21200) 6.7 (22900) 7.2 (24600) 6.0 (20500) 6.5 (22200) 7.0 (23900) 5.7 (19400) 6.2 (21200) 6.7 (22900) Caspian LST (26300) 8.2 (28000) 8.7 (29700) 7.5 (25600) 8.0 (27300) 8.5 (29000) 7.2 (24600) 7.7 (26300) 8.2 (28000) Heat Output at 65 Heat Output at 60 Heat Output at 55 Low Medium High Low Medium High Low Medium High kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) Caspian LST (2600) 1.1 (3900) 1.5 (5100) 0.7 (2400) 1.0 (3400) 1.3 (4400) 0.6 (2200) 0.8 (2900) 1.1 (3600) Caspian LST (8100) 2.8 (9500) 3.2 (10800) 2.1 (7300) 2.5 (8500) 2.9 (9800) 1.9 (6400) 2.2 (7600) 2.6 (8800) Caspian LST (13700) 4.4 (15100) 4.8 (16500) 3.6 (12200) 4.0 (13700) 4.4 (15200) 3.2 (10800) 3.6 (12300) 4.1 (13900) Caspian LST (18100) 5.8 (19800) 6.3 (21500) 4.9 (16700) 5.4 (18400) 5.9 (20100) 4.6 (15700) 5.1 (17400) 5.6 (19100) Caspian LST (23200) 7.3 (24900) 7.8 (26600) 6.4 (21800) 6.9 (23500) 7.4 (25300) 6.1 (20800) 6.6 (22500) 7.1 (24200) Heat Output at 50 Low Medium High kw (Btu/h) kw (Btu/h) kw (Btu/h) Caspian LST (1900) 0.7 (2400) 0.8 (2900) Caspian LST (5600) 2.0 (6700) 2.3 (7800) Caspian LST (9400) 3.2 (10900) 3.7 (12600) Caspian LST (14300) 4.7 (16000) 5.2 (17700) Caspian LST (19400) 6.2 (21200) 6.7 (22900) Heat Output testing based on BS EN442 using mean water temperature, 18 C entering air temperature, 10 deg temperature drop. 18

19 1. Commercial fan convectors Total Power Consumption Flow & Return Mains Flexible Isolation Fused Low Medium High Water Capacity Connections Cable Transformer Hoses Valves Spur (Watts) (Watts) (Watts) (Litres) Caspian LST 60 22mm n/a n/a n/a n/a 3A Caspian LST 90 22mm n/a n/a n/a n/a 3A Caspian LST mm n/a n/a n/a n/a 3A Caspian LST mm n/a n/a n/a n/a 3A Caspian LST mm n/a n/a n/a n/a 3A Sound Levels High Medium Low Casting Fan (dba) (dba) (dba) Colour Only Caspian LST White Caspian LST White Caspian LST White Caspian LST White Caspian LST White Pressure Drop High Medium Low (kpa) (kpa) (kpa) Caspian LST Caspian LST Caspian LST Caspian LST Caspian LST Commercial fan convectors Measured at 3m in front of floor mounted model. EAT 20 C, MWT 75 C, 10 C temperature drop Packed Weight Caspian LST 60 24KG Caspian LST 90 37KG Caspian LST KG Caspian LST KG Caspian LST KG External control harness Plinth Wall mounted room thermostat 22mm flexible hoses Caspian LST Motor EC only EC motors are BMS compliant Finish Casing: zinc-coated steel 1.2mm. Polyester powdercoated: white RAL 9010 Available to special order in any colour Available with anti-microbial or anti-bacterial paint Filter Class G3, 100% polyester, non-washable Installation Suitable for two-pipe central heating systems Pipework access holes on the rear and underside Key operated front access panels Bleed valve accessible on removal of front casing Unit must be earthed Commissioning Check water is hot enough to activate the low temperature cut-out thermostat Regulate the flow to achieve maximum performance Controls Variable heat output controller (mounted within the product) Built-in room thermostat Fan-only Accessories External control harness (for up to 4 products) Plinth (150mm high) to suit each model, available in black or white Wall mounted room thermostat 22mm flexible hoses (pair) Caspian LST All dimensions in mm A B

20 1. Commercial fan convectors 1. Commercial fan convectors Caspian High & Low Caspian low surface temperature fan convectors have been specially developed for a wide range of applications in larger spaces and commercial environments. With the ability to rapidly heat large areas at low cost, Caspian commercial fan convectors are both practical and energy efficient. Fully compatible with renewable energy technology, such as ground and air source heat pumps, Caspian can also enhance your environmental credentials. Supplied as standard in white but can be supplied in any colour. High Level Low Level Heat Output at 80ºC Heat Output at 75ºC Low Medium High Low Medium High Low Level High Level kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) Caspian LL 60/03 Caspian HL 60/ (10900) 3.5 (12000) 3.7 (12800) 2.9 (9900) 3.2 (11000) 3.4 (11600) Caspian LL 60/04 Caspian HL 60/ (13500) 4.5 (15400) 5.1 (17300) 3.6 (12300) 4.1 (14000) 4.6 (15700) Caspian LL 90/06 Caspian HL 90/ (21100) 6.8 (23300) 7.4 (25100) 5.6 (19100) 6.2 (21200) 6.7 (22900 Caspian LL 90/07 Caspian HL 90/ (23300) 7.7 (26300) 8.6 (29300) 6.2 ( (23900) 7.8 (26600) Caspian LL 120/10 Caspian HL 120/ (32300) 11.4 (39000) 12.5 (42800) 8.6 (29300) 10.4 (35500) 11.4 (38900) Caspian LL 120/11 Caspian HL 120/ (35700) 12.5 (42800) 13.4 (45800) 9.5 (32400) 11.4 (38900) 12.2 (41600) Caspian LL 120/12 Caspian HL 120/ (39000) 13.4 (45800) 14.4 (49200) 10.4 (35500) 12.2 (41600) 13.1 (44700) Heat Output at 70ºC Heat Output at 65ºC Low Medium High Low Medium High Low Level High Level kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) Caspian LL 60/03 Caspian HL 60/ (8800) 2.8 (9700) 3.0 (10300) 2.3 (7800) 2.5 (8600) 2.7 (9200) Caspian LL 60/04 Caspian HL 60/ (10900) 3.6 (12500) 4.1 (14000) 2.8 (9700) 3.2 (11000) 3.6 (12400) Caspian LL 90/06 Caspian HL 90/ (17000) 5.5 (18800) 6.0 (20300) 4.4 (15100) 4.9 (16700) 5.3 (18100) Caspian LL 90/07 Caspian HL 90/ (18800) 6.2 (21300) 6.9 (23700) 4.9 (16700) 5.5 (18900) 6.2 (21000) Caspian LL 120/10 Caspian HL 120/ (26100) 9.3 (31600) 10.1 (34600) 6.8 (23200) 8.2 (28000) 9.0 (30700) Caspian LL 120/11 Caspian HL 120/ (28800) 10.1 (34600) 10.9 (37000) 7.5 (25600) 9.0 (30700) 9.6 (32900) Caspian LL 120/12 Caspian HL 120/ (31600) 10.9 (37000) 11.7 (39800) 8.2 (28000) 9.6 (32900) 10.3 (35300) Heat Output at 60ºC Heat Output at 55ºC Low Medium High Low Medium High Low Level High Level kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) Caspian LL 60/03 Caspian HL 60/ (6900) 2.2 (7500) 2.3 (8000) 1.7 (6000) 1.9 (6600) 2.0 (7000) Caspian LL 60/04 Caspian HL 60/ (8500) 2.8 (9700) 3.2 (10800) 2.2 (7300) 2.5 (8400) 2.8 (9400) Caspian LL 90/06 Caspian HL 90/ (13200) 4.3 (14600) 4.6 (15800) 3.4 (11500) 3.7 (12700) 4.0 (13700) Caspian LL 90/07 Caspian HL 90/ (14600) 4.8 (16500) 5.4 (18400) 3.7 (12700) 4.2 (14300) 4.7 (16000) Caspian LL 120/10 Caspian HL 120/ (20200) 7.2 (24500) 7.9 (26800) 5.2 (17600) 6.2 (21300) 6.8 (23400) Caspian LL 120/11 Caspian HL 120/ (22400) 7.9 (26900) 8.4 (28700) 5.7 (19500) 6.8 (23300) 7.3 (25000) Caspian LL 120/12 Caspian HL 120/ (24500) 8.4 (28700) 9.0 (30800) 6.2 (21300) 7.3 (25000) 7.9 (26800) 20

21 1. Commercial fan convectors Heat Output at 50ºC Heat Output at 45ºC Low Medium High Low Medium High Low Level High Level kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) Caspian LL 60/03 Caspian HL 60/ (5100) 1.6 (5600) 1.7 (5900) 1.2 (3950) 1.3 (4350) ) Caspian LL 60/04 Caspian HL 60/ (6250) 2.1 (7100) 2.3 (8000) 1.4 (4900) 1.6 (5600) 1.8 (6300) Caspian LL 90/06 Caspian HL 90/ (9700) 3.2 (10800) 3.4 (11700) 2.2 (7600) 2.5 (8500) 2.7 (9100) Caspian LL 90/07 Caspian HL 90/ (10800) 3.6 (12200) 4.0 (13600) 2.5 (8500) 2.8 (9600) 3.1 (10600) Caspian LL 120/10 Caspian HL 120/ (15000) 5.3 (18100) 5.8 (19800) 3.4 (11700) 4.2 (14200) 4.6 (15600) Caspian LL 120/11 Caspian HL 120/ (16500) 5.8 (19800) 6.2 (21200) 3.8 (13000) 4.6 (15600) 4.9 (16600) Caspian LL 120/12 Caspian HL 120/ (18100) 6.2 (21200) 6.7 (22800) 4.2 (14200) 4.9 (16700) 5.2 (17900) 1. Commercial fan convectors Heat Output at 40ºC Low Medium High Low Level High Level kw (Btu/h) kw (Btu/h) kw (Btu/h) Caspian LL 60/03 Caspian HL 60/ (3050) 1.0 (3400) 1.1 (3600) Caspian LL 60/04 Caspian HL 60/ (3800) 1.3 (4350) 1.4 (4900) Caspian LL 90/06 Caspian HL 90/ (5900) 1.9 (6600) 2.1 (7100) Caspian LL 90/07 Caspian HL 90/ (6600) 2.2 (7400) 2.4 (8300) Caspian LL 120/10 Caspian HL 120/ (9100) 3.2 (11000) 3.5 (12100) Caspian LL 120/11 Caspian HL 120/ (10000) 3.5 (12100) 3.8 (12900) Caspian LL 120/12 Caspian HL 120/ (11000) 3.8 (12900) 4.1 (13900) Heat outputs tested in accordance with BS4856 using mean water temperature, 18 C entering air temperature, 10 C temperature drop. Correction factors Mean Water Temperature C EATºC 80 to Temperature Drop C Factor Sound Levels High Medium Low Casing Low Level High Level (dba) (dba) (dba) Colour Fan-Only Caspian LL 60/03 Caspian HL 60/ White n/a Caspian LL 60/04 Caspian HL 60/ White n/a Caspian LL 90/06 Caspian HL 90/ White n/a Caspian LL 90/07 Caspian HL 90/ White n/a Caspian LL 120/10 Caspian HL 120/ White n/a Caspian LL 120/11 Caspian HL 120/ White n/a Caspian LL 120/12 Caspian HL 120/ White n/a Sound levels measured at 1.5m. Caspian LL 60/03 Caspian LL 60/04 Caspian LL 90/06 Caspian LL 90/07 Caspian LL 120/10 Caspian LL 120/11 Caspian LL 120/12 Caspian HL 60/03 Caspian HL 60/04 Caspian HL 90/06 Caspian HL 90/07 Caspian HL 120/10 Caspian HL 120/11 Caspian HL 120/12 Packed Weight 28KG 28KG 37KG 39KG 48KG 48KG 48KG 24KG 24KG 37KG 39KG 46KG 46KG 46KG Total Power Consumption Flow & Return Mains Flexible Isolating Fused Low Medium High Water Capacity Low Level High Level Connections Cable Transformer Hoses Valves Spur (Watts) (Watts) (Watts) (Litres) Caspian LL 60/03 Caspian HL 60/03 22mm n/a n/a n/a n/a 3A Caspian LL 60/04 Caspian HL 60/04 22mm n/a n/a n/a n/a 3A Caspian LL 90/06 Caspian HL 90/06 22mm n/a n/a n/a n/a 3A Caspian LL 90/07 Caspian HL 90/07 22mm n/a n/a n/a n/a 3A Caspian LL 120/10 Caspian HL 120/10 22mm n/a n/a n/a n/a 3A Caspian LL 120/11 Caspian HL120/11 22mm n/a n/a n/a n/a 3A Caspian LL 120/12 Caspian HL 120/12 22mm n/a n/a n/a n/a 3A

22 1. Commercial fan convectors 1. Commercial fan convectors Caspian High & Low Accessories Thermostat and auto speed control Adjustable low temperature cut-out Wall mounted room thermostat Tamperproof control panel Caspian Low Level Caspian High & Low Motor AC only Finish Casing: zinc-coated steel 1.2mm Polyester powder-coated: white RAL 9010 Available to special order in any colour Available with anti-microbial paint or anti-bacterial paint Filter Class G3, 100% polyester, non-washable Installation Suitable for two-pipe central heating systems Mounting brackets supplied for both models (low level models can sit on the floor) Maximum installation height for high level mounted model - 4m to underside Pipework access holes on the rear and underside (Low) and top (High) Key operated front access panels Bleed valve accessible on removal of front casing Tamperproof control panel (low level models only) Unit must be earthed Commissioning Check water is hot enough to activate the low temperature cut-out thermostat Controls Rocker switch - low/medium/high heat output Illuminated rocker switch - on/off Facility to connect room thermostat Low temperature cut-out thermostat set to energise fan at approximately 35 C Accessories Wall mounted room thermostat Adjustable low temperature cut-out (30 C to 90 C) Thermostat (T1) & auto speed control (T2) Low only Caspian High Level All dimensions in mm A 250 Electrical supply in this side Pipe Centres A See Glossary on page 46 for further information on Accessories 22

23 1. Commercial fan convectors Sterling The Sterling fan-assisted electric heater is a great low cost solution providing effective and dependable heating for both small and large commercial areas, fitted unobtrusively above head height. It has been designed for rooms with limited lower wall space, such as shops and libraries, in mind. 1. Commercial fan convectors Fused Mains Sound Casing Heat Output (kw) Power Consumption (kw) Spur Cable (m) Levels (dba) Colour Fan-Only Electric Sterling E 3kW 1kW/2kW/3kW 1kW/2kW/3kW 13A n/a 39 White Sound levels measured at 1.5m with the product installed at 2.2m high Sterling E 3kw Packed Weight 4KG Sterling Electric E 3kW Sterling Electric Motor AC only Finish Outer casing 0.9mm zinc-coated steel. Polyester powder coated. Paint specification: textured white, BS A01 18% gloss Side panels: Polymer - white Installation Recommended installation height 2.3m (7ft 6") to underside Not suitable for bathrooms and other high humidity areas Angled mounting (optional) 13 amp fused spur required Unit must be earthed Controls Rocker switches for fan and element - fanonly/1kw/2kw/3kw Built-in room thermostat Overheat protection: thermal cut-out. Manual reset procedure: switch power off at mains, wait 20 minutes, switch power on. See Glossary on page 46 for further information on Accessories All dimensions in mm Additional information Electric fan-assisted heaters cost around 15p per hour for each 1kW of heat. versions available - see page

24 1. Commercial fan convectors 1. Commercial fan convectors Caspian Skyline The latest addition to the Caspian range, Caspian Skyline fits into a 600mm x 600mm ceiling tile, providing easy access for both installation and maintenance. It s suitable for projects in schools, retail or food units or where the heating needs to complement the rest of the premise. Using current EC technology, it delivers discreet heating and plumbs easily into the central heating system. The Caspian Skyline has been developed to provide a more easily installed ceiling tile fan convector to complement the Smith s range of Caspian commercial fan convectors and may be used alone or in tandem with other Smith s products. Plumbing easily into any wet central heating system, the Caspian Skyline will also work effectively and efficiently with renewable heat sources, such as air or ground source heat pumps. Heat Output at 80 Heat Output at 75 Heat Output at 70 Low Medium High Low Medium High Low Medium High (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) Caspian Skyline CT (10500) 4.1 (14000) 5.1 (17500) 2.7 (9200) 3.7 (12500) 4.6 (15700) 2.3 (8000) 3.2 (11000) 4.1 (14000) Heat Output at 65 Heat Output at 60 Heat Output at 55 Low Medium High Low Medium High Low Medium High (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) Caspian Skyline CT (7700) 2.9 (10000) 3.6 (12200) 2.2 (7400) 2.6 (8900) 3.1 (10500) 1.5 (5000) 2.0 (6900) 2.6 (8700) Heat Output at 50 Heat Output at 45 Heat Output at 40 Low Medium High Low Medium High Low Medium High (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) Caspian Skyline CT (2600) 1.4 (4800) 2.1 (7000) 0.5 (1700) 0.9 (3000) 1.3 (4400) 0.2 (800) 0.4 (1300) 0.5 (1700) Heat outputs tested in accordance with BS EN442 using mean water temperature, 18 C entering air temperature, 10 C temperature drop. Correction factors Mean Water Temperature C EATºC 80 to Temperature Drop C Factor

25 1. Commercial fan convectors Total Power Consumption Flow & Return Mains Flexible Isolation Fused Low Medium High Water Capacity Connections Cable Transformer Hoses Valves Spur (Watts) (Watts) (Watts) (Litres) Caspian Skyline CT60 22mm n/a n/a n/a n/a 3A Sound Levels High Medium Low Grille Fan (dba) (dba) (dba) Colour Only Caspian Skyline CT White n/a 1. Commercial fan convectors Sound levels measured at 3.0m. Caspian Skyline CT60 Packed Weight 20KG External control harness Adjustable low temperature cut-out 22mm flexible hoses Caspian Skyline Motor EC and AC EC motors are BMS compliant Finish Casing: galvanised steel 1.2mm Grille Eggcrate core, white RAL 9010 complete with touch catches Filter Class G3, 100% polyester, non-washable Installation Suitable for two-pipe central heating systems Maximum installation height 4m to underside Unit must be earthed Commissioning Check water is hot enough to activate the low temperature cut-out thermostat Controls Variable heat output controller (mounted within the product) Accessories Adjustable low temperature cut-out (30 C to 90 C) External control harness (for up to 4 products) 22mm flexible hoses (pair) All dimensions in mm Heater Unit Grille Hanging Ctrs Hanging Ctrs See Glossary on page 46 for further information on Accessories 25

26 1. Commercial fan convectors 1. Commercial fan convectors Skyline The Skyline fits neatly into existing ceiling space - replacing a 600mm x 600mm ceiling tile and because it is ceiling mounted, it saves valuable wall space - particularly important in retail units. It is unobtrusive and effective. Supplied as standard in white but casing can be supplied in any colour. Heat Output at 80ºC Heat Output at 75ºC Heat Output at 70ºC Heat Output at 65ºC Normal Boost Normal Boost Normal Boost Normal Boost kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) Skyline CT (11900) 5.5 (18800) 3.1 (10700) 5.0 (16900) 2.8 (9600) 4.4 (15000) 2.5 (8700) 3.9 (13200) Heat Output at 60ºC Heat Output at 55ºC Heat Output at 50ºC Heat Output at 45ºC Normal Boost Normal Boost Normal Boost Normal Boost kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) Skyline CT (7900) 3.3 (11400) 2.1 (7000) 3.0 (10100) 1.8 (6000) 2.6 (8900) 1.5 (5100) 2.2 (7600) Heat Output at 40ºC Normal Boost kw (Btu/h) kw (Btu/h) Skyline CT (4100) 1.8 (6300) Heat outputs tested in accordance with BS4856 using entering water temperature and 340 l/h (75gph) flow rate. Sound Levels Normal Boost (dba) (dba) Casing Colour Fan-Only Skyline CT White Sound levels measured at 1.5m. Power Consumption Flow and Return Main Flexible Isolating Fused Normal Boost Water Capacity Connections Cable Transformer Hoses Valves Spur (Watts) (Watts) (Litres) Skyline CT18 22mm 1.5m n/a n/a n/a 3A Skyline CT18 Motor AC only Finish Outer casing 0.7mm zinc-coated steel. Polyester powder-coated Paint specification: textured white, BS A01 18% gloss Installation Maximum installation height 3.2m (10'6") to underside Installed to 180mm - penetration depth in recess (excluding fittings) Four air inlet options: room only, void only, room and void, fresh air (spigot required) 600mm side clearance required Fixing brackets (4) supplied for connection to 6mm threaded rods or chains (rods and chains - not supplied) Blanking plates (2) supplied for air circulation options Unit must be earthed Supplied with remote operating switch Suitable for two-pipe central heating systems only Commissioning Check water temperature is hot enough to activate low temperature cut-out (LTC). The inclusion of an automatic air vent at the highest point is recommended to avoid possible air locks Controls Two rocker fan switches - normal/off/boost, fan-heating/fan-only. Low temperature cut-out thermostat set to energise fan at approximately 35 C Accessories Wall mounted room thermostat Fresh air inlet spigot to suit 100mm flexible hose See Glossary on page 46 for further information on Accessories 26 Skyline CT18 Skyline CT18 Packed Weight 20KG 90 Pipe Centres mm Flow and Return Pipes Outlet panel fits over ceiling tile frame Air in void or room damper at both ends 45 centres centres Heat exchanger drain off valve Fixing points 498 centres

27 1. Commercial fan convectors Skyline The electric Skyline fits neatly into existing ceiling space - replacing a 600mm x 600mm ceiling tile and because it is ceiling mounted, it saves valuable wall space - particularly important in retail units. It is unobtrusive and effective. Like its hydronic cousin, this highoutput fan convector effectively heats large areas. Supplied as standard in white but can be supplied in any colour. 1. Commercial fan convectors Heat Output (kw) Power Consumption (kw) Fused Mains Sound Casing Fan-Only Normal Boost Normal Boost Spur Cable (m) Levels (dba) Colour Electric Skyline E 4kW A White n/a Skyline E 4kW Finish Outer casing 0.9mm zinc-coated steel. Polyester powdercoated Paint specification: textured white, BS A01 18% gloss Installation Maximum installation height 3.2m (10'6") to underside Minimum 150mm void space required for recessed installation Not suitable for bathrooms and other high humidity areas Two air inlet options: room only, room and void Maximum flexibility in installation: only 600mm - side clearance required Facility for connection to 6mm threaded rod or chains (rods and chains - not supplied) 20 amp fused spur required Unit must be earthed Supplied with remote operating switch Controls Rocker switches for fan and element Overheat protection: thermal cut-out. Manual reset procedure: switch power off at mains, wait 5 minutes, switch power on Accessories Surface mounting kit - 135mm. Provides a complete foursided trim when fitted to a solid ceiling Ceiling tile spacer - 85mm. Provides semi-recessed profile to match Skyline CT18 when used in ceiling tile frame Room thermostats used in conjunction with Skyline E 4kW must be rated at 20A minimum Additional information 248 centres Skyline E 4kW Multiple positions (14) for suspension points Electric fan-assisted heaters cost around 15p per hour for each 1kW of heat. model available

28 1. Commercial fan convectors 1. Commercial fan convectors Ecovector / Sterling High The Ecovector and Sterling and Low Voltage fan convectors provide effective and dependable heating for both small and large commercial areas, fitted unobtrusively above head height. They work particularly well in shops and libraries, where lower wall space is limited. Supplied as standard in white but casing can be supplied in any colour. Heat Output at 80ºC Heat Output at 75ºC Heat Output at 70ºC Heat Output at 65ºC Normal Boost Normal Boost Normal Boost Normal Boost kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) Ecovector HL (3500) 1.3 (4600) 1.0 (3300) 1.2 (4050) 0.9 (3100) 1.1 (3750) 0.8 (2800) 1.0 (3400) Ecovector HL (7850) 3.1 (10500) 2.1 (7000) 2.8 (9400) 1.9 (6400) 2.5 (8500) 1.7 (5700) 2.1 (7300) Ecovector HL (10000) 4.2 (14500) 2.7 (9200) 4.0 (13500) 2.5 (8500) 3.5 (12000) 2.3 (7700) 3.2 (11000) Ecovector HL (13500) 5.3 (18000) 3.7 (12500) 4.8 (16500) 3.3 (11300) 4.4 (15100) 3.0 (10400) 4.1 (13900) Sterling V 1.0 (3500) 1.3 (4600) 1.0 (3300) 1.2 (4050) 0.9 (3100) 1.1 (3750) 0.8 (2800) 1.0 (3400) Low Voltage Ecovector HL V 1.0 (3500) 1.3 (4600) 1.0 (3300) 1.2 (4050) 0.9 (3100) 1.1 (3750) 0.8 (2800) 1.0 (3400) Sterling V 1.0 (3500) 1.3 (4600) 1.0 (3300) 1.2 (4050) 0.9 (3100) 1.1 (3750) 0.8 (2800) 1.0 (3400) Heat Output at 60ºC Heat Output at 55ºC Heat Output at 50ºC Heat Output at 45ºC Normal Boost Normal Boost Normal Boost Normal Boost kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) Ecovector HL (2550) 0.9 (3200) 0.6 (2100) 0.8 (2750) 0.5 (1850) 0.7 (2400) 0.5 (1600) 0.6 (2000) Ecovector HL (4800) 1.9 (6600) 1.4 (4700) 1.8 (6300) 1.2 (4100) 1.6 (5500) 1.1 (3600) 1.4 (4800) Ecovector HL (7200) 2.9 (9800) 1.9 (6600) 2.6 (8900) 1.6 (5400) 2.3 (7800) 1.4 (4750) 2.0 (6800) Ecovector HL (9100) 3.4 (11500) 2.4 (8200) 3.2 (10900) 2.1 (7150) 2.8 (9600) 1.8 (6300) 2.5 (8400) Sterling V 0.7 (2550) 0.9 (3200) 0.6 (2100) 0.8 (2750) 0.5 (1850) 0.7 (2400) 0.5 (1600) 0.6 (2000) Low Voltage Ecovector HL V 0.7 (2550) 0.9 (3200) 0.6 (2100) 0.8 (2750) 0.5 (1850) 0.7 (2400) 0.5 (1600) 0.6 (2000) Sterling V 0.7 (2550) 0.9 (3200) 0.6 (2100) 0.8 (2750) 0.5 (1850) 0.7 (2400) 0.5 (1600) 0.6 (2000) Heat Output at 40ºC Normal Boost kw (Btu/h) kw (Btu/h) Ecovector HL (1350) 0.5 (1800) Ecovector HL (3000) 1.2 (4000) Ecovector HL (4000) 1.7 (5700) Ecovector HL (5300) 2.1 (7000) Sterling V 0.4 (1350) 0.5 (1800) Low Voltage Ecovector HL V 0.4 (1350) 0.5 (1800) Sterling V 0.4 (1350) 0.5 (1800) Heat outputs tested in accordance with BS4856 using entering water temperature and 340 l/h (75gph) flow rate. Sound Levels Normal Boost Casing (dba) (dba) Colour Fan-Only Ecovector HL White Ecovector HL White Ecovector HL White Ecovector HL White Sterling V White Low Voltage Ecovector HL V White Sterling V White Sound levels measured at 1.5m. 28

29 1. Commercial fan convectors Power Consumption Flow & Return Mains Flexible Isolating Fused Normal Boost Water Capacity Connections Cable Transformer Hoses Valves Spur (Watts) (Watts) (Litres) Ecovector HL mm 1.5m n/a n/a n/a 3A Ecovector HL mm 1.5m n/a n/a n/a 3A Ecovector HL mm 1.5m n/a n/a n/a 3A Ecovector HL mm 1.5m n/a n/a n/a 3A Sterling V 15mm 1.5m n/a n/a n/a 3A Low Voltage Ecovector HL V 15mm 0.45m n/a n/a 3A Sterling V 15mm 0.45m n/a n/a 3A Ecovector HL 1000 Ecovector HL 2300 Ecovector HL 2900 Ecovector HL 4000 Sterling v Packed Weight 7KG 11KG 15KG 18KG 7KG 1. Commercial fan convectors Ecovector HL V Sterling V 8KG 8KG Sterling V, V 540 Electrical supply in this side Pipe Centres Wall mounted room thermostat Ecovector /Sterling High Level Motor AC only Finish Front casing: zinc-coated steel. Polyester powder-coated: textured white BS A01 18% gloss Side panels: polymer eggshell white Ecovector HL 1000, V, 2300, 2900 A Electrical supply in this side Pipe Centres A V Installation 276 Maximum installation height 2.1m (6 11 ) to underside No top or side clearance required 124 Unit must be earthed (except model V) Suitable for two-pipe central heating systems Patress box not supplied for transformer (model V) Commissioning Check water is hot enough to activate the low temperature cut-out thermostat. The inclusion of an automatic air vent at the highest point is recommended to avoid possible air locks Ecovector HL 4000 Electrical supply in this side A Pipe Centres Controls 100 Two rocker switches - normal/off/boost, heating/fan-only Low temperature cut out thermostat, set to energise fan at approximately 35 C Accessory Wall mounted room thermostat All dimensions in mm 124 See Glossary on page 46 for further information on Accessories 29

30 Summary of product ranges - Domestic applications Summary of product ranges - Domestic applications Ecovector /Sterling High Fan convector p32-33 Designed for unobtrusive fixing at high level and ideal for a wide range of living areas. Both hydronic and electric versions available plus a low voltage model for bathrooms. Heat outputs up to 4.0 kw (13500 Btu/h). Ecovector Low Fan convector p34 Combining stylish good looks with energy efficiency, Ecovector Low includes built-in thermostatic control. Heat outputs up to 3.5kW (12100 Btu/h). Eco-Powerad Fan convector p35 The fan convector of the future energy efficient, responsive and capable of installation within most wet central heating systems driven by either boilers or low temperature renewable technology. Heat outputs up to 3.9kW (13200 Btu/h). Ecovector Vertical Fan convectors p36 Designed for installation in narrow spaces like hallways, and other smaller rooms, this vertical low-level wallmounted fan convector includes wireless thermostatic control. Heat output up to 2.6kW (8800 Btu/h). Spacemaker Fan convector p37 Floor-fitted fan convector, ideal for entrance halls and lobbies where wall space is limited. Heat outputs up to 1.6kW (5500 Btu/h). Hydroflame Fan convector p38-40 The Hydroflame hydronic flame-effect fan convectors provide the visual appeal of a real fire but are safer and more energy efficient and fit on any internal or external wall surface, into a fireplace opening or in front of a fireplace surround, affording the homeowner a huge degree of flexibility for room design and layout. Heat outputs up to 2.0kW (6800 Btu/h). Sureline Natural convectors p41 A natural convector fitted at skirting level - the ideal form of perimeter heating, providing gentle low-level warmth anywhere from hallways and conservatories to airing cupboards. Heat outputs up to 820W (2520Btu/h) per metre. Space Saver - Plinth heaters p42-44 Providing an alternative to the traditional radiator, the Smith s Space Saver sits neatly in the plinth at the bottom of your kitchen units to create space for extra cupboards, more work surface and additional appliances. Heat outputs up to 2.4kW (8200 Btu/h). Space Saver - Electric Plinth heaters p45 The Smith s Space Saver SS80 sits neatly in plinths just 8cm deep, common in Scandinavian-style kitchens to create extra space for more cupboards, worktops, appliances or instead of underfloor heating. 30

31 Applications chart Domestic Room Best 444 Better 44 Good 4 Kitchen/Utility Room Space Saver Plinth Ecovector High Ecovector Low Sterling High Eco-Powerad Low Bathroom/En-suite Space Saver Plinth Ecovector High Sterling High Cloakroom Ecovector High Sureline Ecovector Low Sterling High Eco-Powerad Low Hall Ecovector Vertical Ecovector Low Sureline Eco-Powerad Low Landing Ecovector Low Ecovector Vertical Eco-Powerad Low Living Room/Dining Room Ecovector Low Ecovector Vertical Spacemaker Recessed Eco-Powerad Low Fireplace Hydroflame Conservatory Ecovector High Ecovector Vertical Sterling High Bedroom Ecovector Low Sureline Ecovector Vertical Eco-Powerad Low Home Office/Study Ecovector High Ecovector Low Ecovector Vertical Sterling High Eco-Powerad Low Commercial Room Best 444 Better 44 Good 4 Showroom Caspian UV/UVC/FF Skyline Ceiling High Caspian Low Caspian High Ecovector Sureline Caspian Skyline Shop Caspian UV/UVC/FF Skyline Ceiling Ecovector Vertical Caspian High Ecovector High Caspian Skyline Sterling High Entrance Hall/Corridor Caspian UV/UVC/FF Skyline Ceiling Ecovector Vertical Caspian High Ecovector High Sureline Sterling High Spacemaker Recessed Reception Ecovector Low Ecovector Vertical Ecovector High Eco-Powerad Low Sureline Sterling High Caspian High Waiting Room Caspian UV/UVC/FF Skyline Ceiling Ecovector Vertical Caspian High Ecovector High Caspian Low Sterling High Meeting Room/Hall/Club Caspian UV/UVC/FF Skyline Ceiling Ecovector Vertical Caspian High Ecovector High Caspian Skyline Sterling High Changing Room Caspian UV/UVC/FF Skyline Ceiling Ecovector Vertical Caspian High Ecovector High Caspian Skyline Sterling High Public House Caspian UV/UVC/FF Skyline Ceiling Ecovector Vertical Caspian High Ecovector High Caspian Skyline Sterling High Place of Worship Caspian UV/UVC/FF/EXT Ecovector Low Ecovector Vertical Caspian High Eco-Powerad Low Sureline Caspian Low School, Nursery Caspian UV/UVC/FF/EXT Skyline Ceiling Ecovector High Caspian LST Caspian High Sterling High Caspian Skyline Sterling High Care Home, Hospital Caspian UV/UVC/FF Skyline Ceiling Ecovector High Caspian Universal LST Caspian High Sterling High Caspian Skyline Sterling High Sureline Library Caspian UV/UVC/FF Skyline Ceiling Ecovector Low Caspian High Ecovector High Eco-Powerad Low Caspian Skyline Sterling High Summary of product ranges - Domestic applications 31

32 2. Domestic fan convectors 2. Domestic fan convectors Ecovector /Sterling High The Ecovector and Sterling and Low Voltage fan convectors provide effective and dependable heating for both large and small rooms, fitted unobtrusively above head height. They work particularly well in conservatories and areas where lower wall space is limited. Supplied as standard in white but casing can be supplied in any colour. Heat Output at 80ºC Heat Output at 75ºC Heat Output at 70ºC Heat Output at 65ºC Room Size Normal Boost Normal Boost Normal Boost Normal Boost Guide* (m 3 ) kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) Ecovector HL (3500) 1.3 (4600) 1.0 (3300) 1.2 (4050) 0.9 (3100) 1.1 (3750) 0.8 (2800) 1.0 (3400) Ecovector HL (7850) 3.1 (10500) 2.1 (7000) 2.8 (9400) 1.9 (6400) 2.5 (8500) 1.7 (5700) 2.1 (7300) Ecovector HL (10000) 4.2 (14500) 2.7 (9200) 4.0 (13500) 2.5 (8500) 3.5 (12000) 2.3 (7700) 3.2 (11000) Ecovector HL (13500) 5.3 (18000) 3.7 (12500) 4.8 (16500) 3.3 (11300) 4.4 (15100) 3.0 (10400) 4.1 (13900) Sterling V (3500) 1.3 (4600) 1.0 (3300) 1.2 (4050) 0.9 (3100) 1.1 (3750) 0.8 (2800) 1.0 (3400) Low Voltage Ecovector HL V (3500) 1.3 (4600) 1.0 (3300) 1.2 (4050) 0.9 (3100) 1.1 (3750) 0.8 (2800) 1.0 (3400) Sterling V (3500) 1.3 (4600) 1.0 (3300) 1.2 (4050) 0.9 (3100) 1.1 (3750) 0.8 (2800) 1.0 (3400) Heat Output at 60ºC Heat Output at 55ºC Heat Output at 50ºC Heat Output at 45ºC Room Size Normal Boost Normal Boost Normal Boost Normal Boost Guide* (m 3 ) kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) Ecovector HL (2550) 0.9 (3200) 0.6 (2100) 0.8 (2750) 0.5 (1850) 0.7 (2400) 0.5 (1600) 0.6 (2000) Ecovector HL (4800) 1.9 (6600) 1.4 (4700) 1.8 (6300) 1.2 (4100) 1.6 (5500) 1.1 (3600) 1.4 (4800) Ecovector HL (7200) 2.9 (9800) 1.9 (6600) 2.6 (8900) 1.6 (5400) 2.3 (7800) 1.4 (4750) 2.0 (6800) Ecovector HL (9100) 3.4 (11500) 2.4 (8200) 3.2 (10900) 2.1 (7150) 2.8 (9600) 1.8 (6300) 2.5 (8400) Sterling V (2550) 0.9 (3200) 0.6 (2100) 0.8 (2750) 0.5 (1850) 0.7 (2400) 0.5 (1600) 0.6 (2000) Low Voltage Ecovector HL V (2550) 0.9 (3200) 0.6 (2100) 0.8 (2750) 0.5 (1850) 0.7 (2400) 0.5 (1600) 0.6 (2000) Sterling V (2550) 0.9 (3200) 0.6 (2100) 0.8 (2750) 0.5 (1850) 0.7 (2400) 0.5 (1600) 0.6 (2000) Heat Output at 40ºC Room Size Normal Boost Guide* (m 3 ) kw (Btu/h) kw (Btu/h) Ecovector HL (1350) 0.5 (1800) Ecovector HL (3000) 1.2 (4000) Ecovector HL (4000) 1.7 (5700) Ecovector HL (5300) 2.1 (7000) Sterling V (1350) 0.5 (1800) Low Voltage Ecovector HL V (1350) 0.5 (1800) Sterling V (1350) 0.5 (1800) Sound Levels Room Size Normal Boost Casing Guide* (m 3 ) (dba) (dba) Colour Fan-Only Ecovector HL White Ecovector HL White Ecovector HL White Ecovector HL White Sterling V White Low Voltage Ecovector HL V White Sterling V White *Room sizes given in cubic metres for general guidance only based on normal heat output (80ºC) for domestic applications - always calculate heat losses. Heat outputs tested in accordance with BS4856 using entering water temperature and 340 l/h (75gph) flow rate. Fan-only option operational only when central heating system is switched off. Sound levels measured at 1.5m. 32

33 2. Domestic fan convectors Power Consumption Flow & Return Mains Flexible Isolating Fused Normal Boost Water Capacity Connections Cable Transformer Hoses Valves Spur (Watts) (Watts) (Litres) Ecovector HL mm 1.5m n/a n/a n/a 3A Ecovector HL mm 1.5m n/a n/a n/a 3A Ecovector HL mm 1.5m n/a n/a n/a 3A Ecovector HL mm 1.5m n/a n/a n/a 3A Sterling V 15mm 1.5m n/a n/a n/a 3A Low Voltage Ecovector HL V 15mm 0.45m n/a n/a 3A Sterling V 15mm 0.45m n/a n/a 3A Domestic fan convectors Ecovector HL 1000, V, 2300, 2900 Ecovector HL 4000 Electrical supply in this side A Pipe Centres Electrical supply in this side A Pipe Centres All dimensions in mm Sterling V, V Ecovector /Sterling High Finish Front casing: zinc-coated steel. Polyester, powder-coated: textured white BS A01 18% gloss Side panels: polymer eggshell white Electrical supply in this side 540 Pipe Centres Installation Maximum installation height 2.1m (6 11 ) to underside No top or side clearance required Unit must be earthed (except model V) Suitable for two-pipe central heating systems Pattress box not supplied for transformer (model V) 124 Commissioning Check water is hot enough to activate the low temperature cut-out thermostat. The inclusion of an automatic air vent at the highest point is recommended to avoid possible air locks All dimensions in mm Controls Two rocker switches - normal/off/boost, heating/fan-only Low temperature cut out thermostat, set to energise fan at approximately 35 C Accessory Wall-mounted room thermostat A V See Glossary on page 46 for further information on Accessories 33

34 2. Domestic fan convectors 2. Domestic fan convectors Ecovector Low Ecovector Low Level fan convectors provide warmth from the floor upwards and are more energy efficient and effective than radiators. The Ecovector can heat up a room more quickly than radiators, thereby reducing the amount of time your boiler or heat pump is running - making it extremely efficient and cost effective. Ideal for new and existing developments, due to ease of installation, the Ecovector is available in a range of models to suit varying room sizes and heat output requirements. Supplied as standard in white but casing can be supplied in any colour. Heat Output at 80ºC Heat Output at 75ºC Heat Output at 70ºC Heat Output at 65ºC Room Size Guide* (m 3 ) Normal kw (Btu/h) Boost kw (Btu/h) Normal kw (Btu/h) Boost kw (Btu/h) Normal kw (Btu/h) Boost kw (Btu/h) Normal kw (Btu/h) Boost kw (Btu/h) Ecovector LL 1200 Ecovector LL 2000 Ecovector LL (4000) 2.0 (6900) 2.8 (9700) 1.6 (5400) 2.6 (8900) 3.5 (12100) 1.1 (3700) 1.9 (6400) 2.6 (9000) 1.4 (4800) 2.4 (8200) 3.2 (11050) 1.0 (3350) 1.6 (5500) 2.3 (8000) 1.3 (4300) 2.2 (7600) 2.9 (10000) 0.9 (3000) 1.5 (5000) 2.0 (6800) 1.1 (3900) 1.9 (6600) 2.6 (9000) Heat Output at 60ºC Heat Output at 55ºC Heat Output at 50ºC Heat Output at 45ºC Room Size Normal Boost Normal Boost Normal Boost Normal Boost Guide* (m 3 ) kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) Ecovector LL (2600) 1.0 (3450) 0.7 (2250) 0.8 (2900) 0.6 (1900) 0.7 (2500) 0.5 (1600) 0.6 (2050) Ecovector LL (4550) 1.7 (5900) 1.2 (4050) 1.6 (5300) 1.0 (3500) 1.3 (4400) 0.9 (3050) 1.1 (3700) Ecovector LL (6400) 2.4 (8100) 1.5 (5200) 2.1 (7200) 1.3 (4500) 1.8 (6100) 1.2 (4000) 1.5 (5200) Heat Output at 40ºC Room Size Normal Boost Guide* (m 3 ) kw (Btu/h) kw (Btu/h) Ecovector LL (1250) 0.5 (1600) Ecovector LL (2500) 0.8 (2900) Ecovector LL (3250) 1.2 (4200) Total Power Consumption Flow & Return Mains Flexible Isolating Fused Normal Boost Water Capacity Connections Cable Transformer Hoses Valves Spur (Watts) (Watts) (Litres) Sound Levels Room Size Guide* (m 3 ) Normal (dba) Boost (dba) Casing Colour Fan-Only Ecovector LL 1200 Ecovector LL 2000 Ecovector LL White White White n/a n/a n/a *Room sizes given in cubic metres for general guidance only based on normal heat output (80ºC) for domestic applications - always calculate heat losses. Heat outputs tested in accordance with BS4856 using entering water temperature and 340 l/h (75gph) flow rate. Sound levels measured at 1.5m. Ecovector LL mm 1.5m n/a n/a n/a 3A Ecovector LL mm 1.5m n/a n/a n/a 3A Ecovector LL mm 1.5m n/a n/a n/a 3A Ecovector Low Level Finish Front casing: zinc coated steel. Polyester, powder-coated: textured white BS A01 18% gloss Side panels: polymer eggshell white Installation Mounting bracket supplied Unit must be earthed Suitable for two-pipe central heating systems Minimum height above floor level 150mm Maximum height above floor level 500mm Commissioning Check water is hot enough to activate the selectable low temperature cut-out thermostat Controls Rocker switch - normal/off/boost Built-in room thermostat Low temperature cut-out thermostat set to energise fan at approximately 35 C See Glossary on page 46 for further information on Accessories Ø Pipe centres 34 A All dimensions in mm Electrical supply in this side A LL LL LL

35 2. Domestic fan convectors Eco-Powerad The Eco-Powerad is the fan convector of the future - energy efficient, responsive and suitable for installation within most wet central heating systems, driven by either boilers or low temperature renewable technology. Compact, with smooth lines to achieve visual simplicity, the Eco-Powerad also features low surface temperature casing for complete safety and possesses a very low operating sound - between 28 and 32 decibels. Supplied as standard in white but can be supplied in any colour. 2. Domestic fan convectors Heat Heat Heat Heat Heat Heat Heat Heat Heat Output Output Output Output Output Output Output Output Output at 80ºC at 75ºC at 70ºC at 65ºC at 60ºC at 55ºC at 50ºC at 45ºC at 40ºC Room Size kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) Guide* (m 3 ) Eco-Powerad (3100) 0.8 (2900) 0.8 (2750) 0.7 (2400) 0.6 (2050) 0.5 (1875) 0.5 (1700) 0.4 (1375) 0.3 (1050) Eco-Powerad (8200) 2.1 (7150) 1.8 (6100) 1.6 (5450) 1.4 (4775) 1.2 (4100) 1.0 (3400) 0.8 (2725) 0.7 (2400) Eco-Powerad ( (8200) 2.2 (7500) 2.0 (6825) 1.9 (6475) 1.7 (5800) 1.5 (5100) 1.2 (4100) 0.9 (3100) Eco-Powerad (13200) 3.5 (11950) 3.2 (10900) 2.8 (9550) 2.5 (8525) 2.2 (7675) 2.0 (6800) 1.7 (5800) 1.3 (4600) *Room sizes given in cubic metres for general guidance only based on normal heat output (50ºC) for domestic applications - always calculate heat losses. Heat outputs tested in accordance with BS4856 using entering water temperature and 340 l/h (75gph) flow rate. At inlet water temperatures of 75 C and below, all Eco-Powerad models are classified as LST (low surface temperature) appliances. Sound Casing Flow & Mains Flexible Isolating Fused Total Power Water Levels* Colour Return Cable Transformer Hoses Valves Spur Consumption Capacity (dba) Connections (Watts) (Litres) Eco-Powerad White 15mm 2m n/a n/a n/a 3A Eco-Powerad White 15mm 2m n/a n/a n/a 3A Eco-Powerad White 15mm 2m n/a n/a n/a 3A Eco-Powerad White 15mm 2m n/a n/a n/a 3A *Measured at 1.5m. Eco-Powerad Finish Front casing: zinc coated steel Polyester, powder-coated: white RAL 9010 Installation Mounting bracket supplied Unit must be earthed Suitable for two-pipe central heating systems Minimum height above floor level 150mm Maximum height above floor level 500mm Wall-mounted room thermostat 95 A Commissioning Check water is hot enough to activate the low temperature cut-out thermostat. Ensure system is balanced for even heat distribution Controls Low temperature cut-out thermostat, set to energise fan at approximately 35 C Suitable for thermostatic radiator valves (TRV) - not supplied Rocker switch - normal/low min Electrical supply 26 in this side 26 All dimensions in mm A Eco-Powerad Eco-Powerad Eco-Powerad Eco-Powerad Accessory Wall-mounted room thermostat. See Glossary on page 46 for further information on Accessories 35

36 2. Domestic fan convectors 2. Domestic fan convectors Ecovector Vertical Ecovector Vertical is ideal for hallways, alcoves and other places where space is limited. Ecovector can heat up a room more quickly than radiators, thereby reducing the amount of time your boiler or heat pump is running - making it extremely efficient and cost effective. Ideal for new and existing housing developments, due to ease of installation. Supplied as standard in white but can be supplied in any colour. Heat Output at 80ºC Heat Output at 75ºC Heat Output at 70ºC Heat Output at 65ºC Room Size Normal Boost Normal Boost Normal Boost Normal Boost Guide* (m 3 ) kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) Ecovector VE (8500) 2.6 (8800) 2.3 (7800) 2.4 (8200) 2.0 (6900) 2.1 (7300) 1.9 (6400) 2.0 (6700) Heat Output at 60ºC Heat Output at 55ºC Heat Output at 50ºC Heat Output at 45ºC Room Size Normal Boost Normal Boost Normal Boost Normal Boost Guide* (m 3 ) kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) Ecovector VE (5800) 1.8 (6000) 1.5 (5100) 1.5 (5200) 1.3 (4400) 1.3 (4600) 1.1 (3800) 1.1 (3900) Heat Output at 40ºC Room Size Normal Boost Guide* (m 3 ) kw (Btu/h) kw (Btu/h) Ecovector VE (3200) 1.0 (3400) Power Consumption Flow & Return Mains Flexible Isolating Fused Normal Boost Water Capacity Connections Cable Transformer Hoses Valves Spur (Watts) (Watts) (Litres) Sound Levels Room Size Normal Boost Casing Guide* (m 3 ) (dba) (dba) Colour Fan-Only Ecovector VE White n/a *Room sizes given in cubic metres for general guidance only based on normal heat output (80ºC) for domestic applications - always calculate heat losses. Heat outputs tested in accordance with BS4856 using entering water temperature and 340 l/h (75gph) flow rate. Fan-only option operational only when central heating system is switched off. Ecovector VE mm 1.5m n/a n/a n/a 3A Ecovector Vertical Finish Front casing and side panels: zinc-coated steel. Polyester, powder-coated: textured white BS A01 18% gloss Installation Mounting bracket supplied Unit must be earthed Suitable for two-pipe central heating systems Minimum height above floor level 150mm, maximum height above floor level 500mm 770 Commissioning Check water is hot enough to activate the selectable low temperature cut-out thermostat 16 Controls Rocker switch - normal/off/boost Low temperature cut-out thermostat set to energise fan at approximately 35 C Pipe Ctrs Electrical Supply in this side 100 Min Wireless wall mounted thermostat included with this product All dimensions in mm See Glossary on page 46 for further information on Accessories 36

37 2. Domestic fan convectors Spacemaker Perfect for places in the home where space is particularly limited. A fan convector that installs flush with the floor, providing efficient and effective heat at low level. Ideal for spaces such as entrance halls, lobbies, circulation areas and applications where wall space is limited. 2. Domestic fan convectors Heat Output at 80ºC Heat Output at 75ºC Heat Output at 70ºC Heat Output at 65ºC Room Size Normal Boost Normal Boost Normal Boost Normal Boost Guide* (m 3 ) kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) Spacemaker SST (5500) 2.2 (7500) 1.5 (5000) 2.1 (7100) 1.3 (4400) 1.8 (6100) 1.2 (4100) 1.7 (5800) Heat Output at 60ºC Heat Output at 55ºC Heat Output at 50ºC Heat Output at 45ºC Room Size Normal Boost Normal Boost Normal Boost Normal Boost Guide* (m 3 ) kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) Spacemaker SST (3700) 1.5 (5100) 0.9 (3200) 1.3 (4500) 0.8 (2800) 1.2 (4000) 0.7 (2400) 1.0 (3400) Heat Output at 40ºC Room Size Normal Boost Guide* (m 3 ) kw (Btu/h) kw (Btu/h) Spacemaker SST (1900) 0.9 (3000) Sound Levels Room Size Normal Boost Guide* (m 3 ) (dba) (dba) Casing Colour Fan-Only Spacemaker SST Anodised n/a aluminium grille *Room sizes given in cubic metres for general guidance only based on normal heat output (80ºC) for domestic applications - always calculate heat losses. Heat outputs tested in accordance with BS4856 using entering water temperature and 340 l/h (75gph) flow rate. Sound levels measured at 1.5m. Power Consumption Flow & Return Mains Flexible Isolating Fused Normal Boost Water Capacity Connections Cable Transformer Hoses Valves Spur (Watts) (Watts) (Litres) Spacemaker SST8 15mm 1.5m n/a n/a n/a 3A Spacemaker SST8 Finish Anodised aluminium grille with removable centre section. Installation Installs between floor joists or purpose made trenches in concrete floors Air intake and discharge through grille Unit must be earthed Suitable for two-pipe central heating systems only Commissioning Check water temperature is hot enough to activate low temperature cut-out (LTC). Vent screw accessible through grille Controls Rocker switch - normal/off/boost, below grille Low temperature cut-out thermostat set to energise fan at approx. 35 C Accessories Wall-mounted room thermostat See Glossary on page 46 for further information on Accessories Wall-mounted room thermostat Spacemaker SST8 Floor cut out size: 357 x 254 Air flow pattern Pipe Centres All dimensions in mm

38 3. Flame-effect fan convectors 3. Flame-effect fan convectors Hydroflame Flame-effect fan convectors that run off the central heating system, but with all the visual appeal of a real fire a beautiful feature in any room. Efficient, cost effective and totally safe, with no harmful discharges. Ideal for children and the elderly because there are no flames or hot surfaces. Available in Inset or Freestanding and a choice of eyecatching designs. Hydroflame Classic and Elite can be supplied with an attractive choice of trims and complementary fireplace surrounds. Heat Output at 80ºC Heat Output at 75ºC Heat Output at 70ºC Heat Output at 65ºC Room Size Normal Boost Normal Boost Normal Boost Normal Boost Guide* (m 3 ) kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) Inset (Classic & Elite) (5100) 2.0 (6800) 1.3 (4600) 1.8 (6200) 1.2 (4100) 1.6 (5500) 1.1 (3700) 1.5 (5100) Freestanding (Classic & Elite) (5100) 2.0 (6800) 1.3 (4600) 1.8 (6200) 1.2 (4100) 1.6 (5500) 1.1 (3700) 1.5 (5100) /Electronic (Dual) Inset Dual (Classic & Elite) (5100) 2.0 (6800) 1.3 (4600) 1.8 (6200) 1.2 (4100) 1.6 (5500) 1.1 (3700) 1.5 (5100) Freestanding Dual (Classic & Elite) (5100) 2.0 (6800) 1.3 (4600) 1.8 (6200) 1.2 (4100) 1.6 (5500) 1.1 (3700) 1.5 (5100) Heat Output at 60ºC Heat Output at 55ºC Heat Output at 50ºC Heat Output at 45ºC Room Size Normal Boost Normal Boost Normal Boost Normal Boost Guide* (m 3 ) kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) Inset (Classic & Elite) (3200) 1.3 (4500) 0.8 (2600) 1.1 (3900) 0.7 (2300) 1.0 (3500) 0.6 (2000) 0.9 (3000)) Freestanding (Classic & Elite) (3200) 1.3 (4500) 0.8 (2600) 1.1 (3900) 0.7 (2300) 1.0 (3500) 0.6 (2000) 0.9 (3000) /Electronic (Dual) Inset Dual (Classic & Elite) (3200) 1.3 (4500) 0.8 (2600) 1.1 (3900) 0.7 (2300) 1.0 (3500) 0.6 (2000) 0.9 (3000) Freestanding Dual (Classic & Elite) (3200) 1.3 (4500) 0.8 (2600) 1.1 (3900) 0.7 (2300) 1.0 (3500) 0.6 (2000) 0.9 (3000) Heat Output at 40ºC Room Size Normal Boost Guide* (m 3 ) kw (Btu/h) kw (Btu/h) Inset (Classic & Elite) (1700) 0.8 (2600) Freestanding (Classic & Elite) (1700) 0.8 (2600) /Electronic (Dual) Inset Dual (Classic & Elite) (1700) 0.8 (2600) Freestanding Dual (Classic & Elite) (1700) 0.8 (2600) Sound Levels Room Size Normal Boost Flame-Effect Guide* (m 3 ) (dba) (dba) Trim Colour Only Inset (Classic & Elite) Brass or Chrome Freestanding (Classic & Elite) Brass or Chrome /Electronic (Dual) Inset Dual (Classic & Elite) Brass or Chrome Freestanding Dual (Classic & Elite) Brass or Chrome In hydronic mode In electric mode *Room sizes given in cubic metres for general guidance only based on normal heat output (80ºC) for domestic applications - always calculate heat losses. Heat outputs tested in accordance with BS4856 using entering water temperature and 340 l/h (75gph) flow rate. Fan-only option operational only when central heating system is switched off. Dual models include an electric element which in electric heating mode will emit 1.5kW of heat. Sound levels measured at 1.5m. 38

39 Power Consumption Flow & Return Mains Flexible Isolating Fused Normal Boost Water Capacity Connections Cable Transformer Hoses Valves Spur (Watts) (Watts) (Litres) Inset (Classic & Elite) 15mm 2.0m n/a 3A Freestanding (Classic & Elite) 15mm 2.0m n/a 3A /Electric (Dual) Inset Dual (Classic & Elite) 15mm 2.0m n/a 10A Freestanding Dual (Classic & Elite) 15mm 2.0m n/a 10A Inset & Inset Dual Pipes Ø Freestanding & Freestanding Dual Pipes Ø In hydronic mode In electric mode Fireplace Surround All dimensions in mm Flame-effect fan convectors Hydroflame Classic & Elite Connects to and runs from your central heating system (hydronic mode) Installation Inset model designed for a recess 400mm x 550mm high Unit must be earthed Suitable for two-pipe central heating systems only Surface temperature of the casing complies with the safety requirement DHSS DN4 Commissioning Check water temperature is hot enough to activate low temperature cut-out device (LTC) Controls Two rocker switches - normal/off/boost, flame-effect on/flame-effect off Variable low temperature cut-out device factory set to energise fan at approximately 40 C. Set temperature can be adjusted higher or lower during installation Built-in room thermostat Hydroflame Dual Classic & Elite Connects to and runs from your central heating system (hydronic mode), but also includes an electric heating element for use when the central heating is switched off Installation Inset Dual model designed for a recess 400mm x 550mm high Unit must be earthed Suitable for two-pipe central heating systems only Surface temperature of the casing complies with the safety requirement DHSS DN4 Commissioning Check water temperature is hot enough to activate low temperature cut-out device (LTC) Controls Three rocker switches - normal/off/boost, hydronic/electric, flame-effect on/flame-effect off Variable low temperature cut-out device factory set to energise fan at approximately 40 C Set temperature can be adjusted higher or lower during installation Built-in room thermostat Cream with cream back plate and hearth Hydroflame design options Type Hydroflame Elite Brass Trim Colour Chrome Inset Inset Dual Freestanding Freestanding Dual Hydroflame Classic Inset Inset Dual Freestanding Freestanding Dual Yew with black back plate and hearth Yew with cream back plate and hearth Antique Oak with black back plate and oak hearth Antique Oak with cream back plate and oak hearth Freestanding Classic Chrome Freestanding Classic Brass Freestanding Elite Brass Freestanding Elite Chrome 39

40 3. Flame-effect fan convectors 3. Flame-effect fan convectors How Hydroflame works Hot water from the central heating system passes through a heat exchanger and transfers its heat to the aluminium fins. Warm air Cooler air is drawn in at floor level and used to create the flame-effect. The air is heated as it passes over the heat exchanger, a patented process that creates a realistic flameeffect, and then expelled gently back into the room. Heat exchanger This gives a more even temperature and will heat a room in much less time than a traditional panel radiator. Plumbed into central heating system The fan will not come into operation until the central heating system water passing through the heat exchanger reaches 40 C (or the temperature set by the installer). This ensures that cooler air is not circulated at start up and allows Hydroflame to switch on and off automatically in conjunction with the central heating system. Flame-effect Coals Lamp Flame-effect fan convectors are energy efficient and in the home will add less than 10.00* to your annual heating bill. Dual models include an electric heating element ideal in spring and summer when you may need a quick warm up but the central heating system is switched off. Cool air Note: *based on electricity charged at 15p/kWh. Features & benefits Completely safe Hydroflame is safe because it uses water from the central heating system to produce heat. No independent gas supply needed No flue gases are produced so a flue and CO detector are not required No live flames, hot coals or elements Low surface temperatures Minimal running costs Hydroflame has a unique method of operation that brings significant savings on running costs. Operates as part of the central heating system, where average usage on normal heat output will add less than a year to annual heating bills (excluding any separate use of the electric heating element on Dual models). See table of running costs. Environmentally friendly Hidden fixings for extra security Hydroflame has less of an impact on the environment than electric, gas or open fire alternatives. No minimum room size No harmful gases expelled to the atmosphere A beautiful focal feature in the room Automatic response to water temperature, providing the correct amount of heat when needed No special ventilation required Stylish and attractive appearance characterises Hydroflame s innovative design. Fit on any internal or external wall surface, into a fireplace opening, or in front of a fireplace surround Thermostatically controlled Can be used simply to replace an existing panel radiator Energy saving light bulb Can show a comforting flame-effect with or without the heating being switched on Simple controls Operating Hydroflame could not be simpler. For full installation instructions refer to the Hydroflame Installation & User Guide, which is available on request; or download it from Low maintenance Cost effective and convenient. No need for annual servicing or safety checks so no access to the property is required Easy to change the lamp Easy for homeowner to clean the filter system Very low water content Each Hydroflame has a very low water content of 0.36 litres, around 5% of the water content of an equivalent output steel panel radiator. Slower fan speed for flame-effect only reduces energy consumption Easy to install Hydroflame is economical and straightforward to install No gas supply or flue required fix to any wall, internal and external Hydroflame running costs (s fitted with 11W energy-saving long-life bulb) Annual Usage (Hours) Running Costs ( ) 11W Bulb 29W Fan Annual Total Clearly labelled, easy action rocker switches No chimney or flue liners required Easy to use by elderly or infirm people Inset models fit standard fireplace openings no need for a replacement surround Flexible hoses, isolation valves and pre-wired electric cable supplied as standard Connects to standard central heating pipe work Assumptions Electricity charged at 15p per kwh. Hydroflame operating on normal - 1.5kW heat output. Excludes use of electric heating element.

41 4. Natural Convectors (perimeter heating) Sureline The Sureline provides gentle, discreet and efficient low-level warmth and is the ideal heating solution for areas where wall space is limited - rooms such as loft conversions and new-build. Simple to install along the skirting in any room, Sureline is an efficient natural convector that provides discreet heating. Supplied as standard in white but casing can be supplied in any colour. Sureline with TRV 4. Natural Convectors (perimeter heating) Heat Output Flow Rate average water temperature average water temperature L/h (G/h) 50 C 55 C 60 C 65 C 70 C 75 C 80 C 50 C 55 C 60 C 65 C 70 C 75 C 80 C Two supplies - Parallel 920 (200) Bottom supply - Top return 920 (200) All heat outputs relate to 1 metre length Heating element Length includes casing, element, backplate and joining strip LH and RH valve box/end stop kit (RH shown) 17 Length A Minimum overlap 20mm Element Front casing mm overlap on cover Backplate Joining strip Sureline Finish Outer casing 0.7mm zinc coated steel. Polyester, powdercoated. Paint specification: textured white BS A01 18% gloss. Each length includes casing, element, backplate and joining strip. Casing only includes casing, backplate and joining strip Installation Minimum clearance above floor 50mm Flow and return connections 22mm copper Designed for system pressures up to 10 bar Suitable for two-pipe central heating systems only Attachments Casing only (1000mm) LH valve box/end cap kit Centre valve cover RH valve box/end cap kit 90 internal cover 90 external cover 135 internal cover 135 external cover Finger guard 500 (500mm) Finger guard 1000 (1000mm) Customised requirements Element (1000mm) We are able to offer casings painted in any colour. Price and availability will be confirmed at the time of order See Glossary on page 46 for further information on Accessories Body with open bottom Plan view Plan view Plan view External corner Finger guard or 1000 *We recommended the use of finger guards in installations where infants have access to the underside of Sureline Centre valve cover Plan view 90 Internal corner 135 Internal corner 135 External corner All dimensions in mm Length A (mm) Sureline Sureline Sureline Sureline 1000C* 1000 Sureline * casing only

42 5. Plinth Heaters - 5. Plinth Heaters - Space Saver A highly energy efficient fan convector that fits neatly into the plinth of a kitchen unit. Space Saver eliminates the need for conventional radiators. And, as its name implies, this brings considerable space saving benefits - more room for extra storage units, more work surfaces, more space for kitchen appliances. Space Saver is used predominantly for domestic applications where the ingenious plinthmounting feature makes it ideal for heating kitchens and utility rooms. Plinth mounting also makes Space Saver ideal for certain non-domestic applications such as reception areas, changing rooms, libraries, etc. Before After Heat Output at 80ºC Heat Output at 75ºC Heat Output at 70ºC Heat Output at 65ºC Room Size Normal Boost Normal Boost Normal Boost Normal Boost Guide* (m 3 ) kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) SS (2900) 1.1 (3600) 0.8 (2700) 0.9 (3200) 0.7 (2500) 0.8 (2800) 0.6 (2200) 0.7 (2500) SS3 (Improved heat output) (3800) 1.4 (4800) 1.0 (3400) 1.3 (4400) 0.9 (3100) 1.2 (4100) 0.8 (2700) 1.1 (3800) SS (4400) 1.7 (5800) 1.2 (4100) 1.6 (5500) 1.1 (3800) 1.4 (4700) 1.0 (3400) 1.3 (4400) SS (5500) 1.9 (6500) 1.4 (4800) 1.8 (6100) 1.3 (4400) 1.6 (5500) 1.2 (4100) 1.5 (5000) SS (7500) 2.4 (8200) 2.1 (7000) 2.2 (7500) 1.8 (6300) 2.0 (6900) 1.7 (5900) 1.8 (6300) Low Voltage SS5 12V (4400) 1.7 (5800) 1.2 (4100) 1.6 (5500) 1.1 ( (4700) 1.0 (3400) 1.3 (4400) /Electric (Dual) SS5 Dual (4400) 1.7 (5800) 1.2 (4100) 1.6 (5500) 1.1 ( (4700) 1.0 (3400) 1.3 (4400) Heat Output at 60ºC Heat Output at 55ºC Heat Output at 50ºC Heat Output at 45ºC Room Size Normal Boost Normal Boost Normal Boost Normal Boost Guide* (m 3 ) kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) kw (Btu/h) SS (1900) 0.7 (2300) 0.5 (1700) 0.6 (2000) 0.4 (1400) 0.5 (1700) 0.35 (1200) 0.4 (1400) SS3 (Improved heat output) (2400) 1.0 (3400) 0.6 (2000) 0.9 (3100) 0.5 (1700) 0.8 (2700) 0.4 (1400) 0.7 (2400) SS (3100) 1.1 (3800) 0.8 (2700) 1.0 (3400) 0.7 (2400) 0.9 (3100) 0.6 (2000) 0.8 (2700) SS (3800) 1.3 ( (3400) 1.2 (4000) 0.9 (3100) 1.0 (3400) 0.8 (2700) 0.9 (3000) SS (5200) 1.7 (5700) 1.3 (4500) 1.5 ( (3900) 1.3 (4300) 0.9 (3200) 1.1 (3700) Low Voltage SS5 12V ( (3800) 0.8 (2700) 1.0 (3400) 0.7 (2400) 0.9 (3100) 0.6 (2000) 0.8 (2700) /Electric (Dual) SS5 Dual ( (3800) 0.8 (2700) 1.0 (3400) 0.7 (2400) 0.9 (3100) 0.6 (2000) 0.8 (2700) In hydronic mode In electric mode *Room sizes given in cubic metres for general guidance only based on normal heat output (80ºC) for domestic applications - always calculate heat losses. Heat outputs tested in accordance with BS4856 using entering water temperature and 340 l/h (75gph) flow rate. Fan-only option operational only when central heating system is switched off. Dual models include an electric element which in electric heating mode will emit 1kW of heat. 42

43 Heat Output at 40ºC Room Size Normal Boost Guide* (m 3 ) kw (Btu/h) kw (Btu/h) SS (900) 0.3 (1100) SS3 (Improved heat output) (1000) 0.6 (2000) SS (1700) 0.7 (2400) SS (2000) 0.8 (2700) SS (2500) 0.9 (3000) Low Voltage SS5 12V (1700) 0.7 (2400) /Electric (Dual) SS5 Dual (1700) 0.7 (2400) Sound Levels Room Size Normal Boost Fascia Grille Guide* (m 3 ) (dba) (dba) Finish Fan-Only SS Stainless Steel SS Stainless Steel SS Stainless Steel SS Stainless Steel SS Stainless Steel Low Voltage SS5 12V Stainless Steel /Electric (Dual) SS5 Dual Stainless Steel Sound levels measured at 1.5m. 5. Plinth Heaters - In hydronic mode In electric mode *Room sizes given in cubic metres for general guidance only based on normal heat output (80ºC) for domestic applications - always calculate heat losses. Heat outputs tested in accordance with BS4856 using entering water temperature and 340 l/h (75gph) flow rate. Fan-only option operational only when central heating system is switched off. Dual models include an electric element which in electric heating mode will emit 1kW of heat. Power Consumption Flow & Return Mains Flexible Isolating Fused Normal Boost Water Capacity Connections Cable Transformer Hoses Valves Spur (Watts) (Watts) (Litres) SS80 15mm 2.0m n/a n/a 3A SS3 15mm 2.0m n/a n/a n/a 3A SS5 15mm 2.0m n/a n/a 3A SS7 15mm 2.0m n/a n/a 3A SS9 15mm 2.0m n/a n/a 3A Low Voltage SS5 12V 15mm 0.45m n/a 3A /Electric (Dual) SS5 Dual 15mm 2.0m n/a n/a 5A n/a In hydronic mode In electric mode 43

44 5. Plinth Heaters - 5. Plinth Heaters - Accessories Wall-mounted room thermostat Brown Gold Black SS Chrome SS3, SS5, SS5 12V, SS Wall-mounted on/off switch White Aluminium Alternative Grille Finishes Space Saver models are supplied with a detachable brushed steel fascia grille. Fascia grilles are also available in the above colours. 89 Smiths Pipe centres Space Saver Fascia Grille Finish Stainles Steel Installation Important: Correct fascia grille opening must be cut to allow sufficient air intake 20mm clearance above unit required secured to plinth by two screws through fascia grille Unit must be earthed (not 12 volt SELV) Suitable for two-pipe central heating systems only SS80 supplied with detachable cable SS80 models have easy fit thermostat facility Accessories Wall-mounted room thermostat SS80: Grilles: brown - RAL 8016, black - RAL 9005, white - RAL 9010 All other models: Grilles: brown - RAL 8016, black - RAL 9005, white - RAL 9010, chrome, aluminium, gold Wall mounted control switch (white) to suit SS3, SS5, SS5/12V, SS7, SS9 Commissioning Check water temperature is hot enough to activate low temperature cut-out thermostat (LTC). Vent screw accessible through fascia grille Controls Single rocker switch - low/off/normal SS80: Low temperature cut-out thermostat set to energise fan at approximately 35 C SS5 W/Dual: three rocker switches, heating/off/fan-only, hydronic/electric, normal/boost Low temperature cut-out thermostat set to energise fan at approximately 35 C All other models: two rocker switches -normal/off/boost, heating/fan-only Low temperature cut-out thermostat set to energise fan at approximately 35 C See Glossary on page 46 for further information on Accessories SS9 98 SS5 Dual 89 Smiths Pipe centres Pipe centres All dimensions in mm

45 6. Plinth Heaters - Electric Space Saver The Space Saver offers increased flexibility and space in kitchen design as it enables the removal of radiators that may be using up valuable wall space. Fitting discreetly into the plinth of a kitchen, the Space Saver provides efficient and effective heat at low level. shown SS2E, other models have different grille and switch configurations. 6. Plinth Heaters - Electric Before After Heat Output (kw) Power Consumption (kw) Fused Mains Sound Fascia Grille Fan-Only Spur Cable (m) Levels (dba) Finish** Colour Electric Space Saver SS3E 1kW/2kW/3kW 1kW/2kW/3kW 13A Brushed Steel Space Saver SS2E 1kW/2kW 1kW/2kW 10A Brushed Steel Space Saver SS80E 0.6kW/1.2kW 0.6kW/1.2kW 10A Stainless Steel Sound levels measured at 1.5m. Space Saver Fascia Grille Finish** - SS2E and SS3E Zinc coated steel polyester, powder coated - metallic silver (referred to as Brushed Steel) Fascia Grille Finish - SS80E Stainless Steel Installation Important: Correct fascia grille opening must be cut to allow sufficient air intake SS2E and SS3E - 20mm clearance above unit required SS80E - 10mm clearance above unit required secured to plinth by two screws through fascia grille Unit must be earthed Accessories - SS2E Wall-mounted room thermostat Grilles: brown - RAL 8016, black - RAL 9005, white - RAL 9010, chrome, aluminium, gold Alternative grilles for SS2E fit over the supplied grille Wall-mounted control switch (white) to suit SS2E Accessories - SS80, SS80E Wall mounted room thermostat Grilles: brown - RAL 8016, black - RAL 9005, white - RAL 9010 Controls Overheat protection: thermal cut-out. Manual reset procedure: switch power off at unit or mains, wait 5 minutes, switch power on SS2E - three rocker switches On/off, 1kW, 2kW SS3E - Push on/off switch, two rockers switches 1kW, 2kW, 3kW SS80E - three rocker switches On/off, 0.6kW, 1.2kW See Glossary on page 46 for further information on Accessories Wall-mounted room thermostat SS2E Additional information SS3E SS80E All dimensions in mm Electric fan-assisted heaters cost around 15p per hour for each 1kW of heat. models available

46 Glossary Glossary Smith s Accessories Wall mounted room thermostat - This accessory measures room temperature and switches off the heater when the set temperature is reached. The thermostat connects directly into either the heater s terminal block or power supply. Wall mounted control switch - Allows the product to be controlled from a switch mounted on the wall rather than the product. Linking to the heater is made by replacing the existing switch connections with the connections on the control switch. Flexible hoses - Flexible connections are a convenient way of connecting a heater into your system. They will provide an easy to achieve connection from your first-fix pipe work. In addition they will provide for a level of expansion and contraction in rigid pipe work and mitigating possible sound and vibration transmission. Adjustable low temperature cut-out (LTC) - This cut out device allows the user to set the water temperature (between 30ºC and 90ºC) at which the product will start to emit heat. It is more accurate than the standard fitted LTC (set at 35ºC) and enables more flexible use with both low system temperature heat pumps and higher system temperature boilers including biomass that can produce 80ºC flow temperatures. Plinth - The optional plinth creates an attractive floor standing unit and also conceals the pipe work from view. This can also be invaluable where it is necessary to prevent contact with heating pipes by vulnerable groups. External control harness - This accessory allows up to four products to be controlled from a single point. An External Control Harness will be required for each product. Each harness has plug and play connections. Proportional Heat Output Controller (PHOC) - This accessory controls the fan speed and hence the heat output of the unit. When the room temperature is below 15ºC the fan speed will run at its maximum speed to give fastest heat up time. When the room temperature reaches 15ºC the fan speed and heat output are modulated down progressively as the room temperature increases towards the set temperature. Thermostat and Auto-Speed control (T1/T2) - This accessory serves two purposes. Firstly, it becomes an integral room thermostat for the unit providing localised control and secondly, the heat output will be changed according to the temperature in the room. For example, the fan may work on full power up to 18ºC and above this temperature move to a lower fan speed. Normally the fan speeds used will be medium and low. Fresh air inlet spigot - An air inlet spigot is available for 100mm diameter rigid or flexible pipe. The spigot allows for a portion of air entering the appliance to be fresh air from outside the building. This ensures an adequate air change rate and improved air quality. Surface mounting kit - Provides a complete four-sided trim when fitted to a solid ceiling, 135 mm high. Ceiling tile spacer - Provides semi-recessed profile to match Skyline CT18 when used in ceiling tile frame, 85mm high. 46

47

Providing comfort for the built environment

Providing comfort for the built environment Providing comfort for the built environment Product Catalogue August 2018 2 SmithsEP.co.uk Why choose Smith s? If you require energy efficiency and versatility in your heating and cooling, the Smith s

More information

heating Versatile, energy efficient Fan convectors, flame-effect fan convectors and natural convectors 24% more energy efficient

heating Versatile, energy efficient Fan convectors, flame-effect fan convectors and natural convectors 24% more energy efficient Uniclass L75622 CI/SfB (56.9) X March 2009 24% more energy efficient Versatile, energy efficient heating Fan convectors, flame-effect fan convectors and natural convectors Contents Page The Way Forward

More information

Hydroflame Patented. 1 of 5. Domestic Applications. Inset Elite Brass. Freestanding Classic Brass. Freestanding Elite Brass

Hydroflame Patented. 1 of 5. Domestic Applications. Inset Elite Brass. Freestanding Classic Brass. Freestanding Elite Brass Freestanding Classic Brass Freestanding Elite Brass Freestanding Classic Chrome Inset Elite Brass NEW FLAME EFFECT Freestanding Elite Chrome Flame-effect fan convectors that run off the central heating

More information

Hydroflame. Flame-effect fan convectors Installation and User Guide Elite and Classic Models. Contents

Hydroflame. Flame-effect fan convectors Installation and User Guide Elite and Classic Models. Contents Hydroflame Flame-effect fan convectors Installation and User Guide Elite and Classic Models Contents Installation General Notes Inset and Inset Dual Freestanding and Freestanding Dual Commissioning Fault

More information

Space Saver. Installation and user manual SS3 SS5 SS7 SS9. Issue 001 September 2017 ENGLISH UK IRL SmithsEP.co.uk

Space Saver. Installation and user manual SS3 SS5 SS7 SS9. Issue 001 September 2017 ENGLISH UK IRL SmithsEP.co.uk Space Saver Installation and user manual SS3 SS5 SS7 SS9 Issue 001 September 2017 ENGLISH UK IRL SmithsEP.co.uk Contents Introduction 2 Declaration of conformity 3 Symbols used in this guide 3 Important

More information

Signature, Sovereign, Sentry, Sentinel, Staccato Fan-Assisted Radiator. Installation & User Guide

Signature, Sovereign, Sentry, Sentinel, Staccato Fan-Assisted Radiator. Installation & User Guide Signature, Sovereign, Sentry, Sentinel, Staccato Fan-Assisted Radiator Installation & User Guide Dear Installer, The following items should be included in the carton; Product complete with pre-wired mains

More information

Sovereign Double CC/DD

Sovereign Double CC/DD Sovereign Double CC/DD Range of Low Surface Temperature radiator models to suit all budgets and applications Sales 01787 274135 www.autron.co.uk The Autron Sovereign DBL LST radiator range is designed

More information

Metropolitan high output natural and powered trench heaters

Metropolitan high output natural and powered trench heaters Metropolitan high output natural and powered trench heaters High output trench heaters Typically used in large glazed areas to reduce glazing losses, these units are the perfect way to enhance comfort.

More information

Aegean Range. A new range of fan coils for heating and cooling commercial applications

Aegean Range. A new range of fan coils for heating and cooling commercial applications egean Range new range of fan coils for heating and cooling commercial applications How Fan Coils work Fan Coils provide heating and cooling solutions for a wide range of applications. Fan Coil Unit (FCU)

More information

LOW SURFACE TEMPERATURE RADIATORS

LOW SURFACE TEMPERATURE RADIATORS JULY 2017 LOW SURFACE TEMPERATURE RADIATORS www.qrl-radiators.com/lst Page 03 LST RANGE SUMMARY Page 0-0 LST RANGE SPECIFICATIONS Page 0 RESISTANCE DIAGRAM Page 0 MOUNTING DETAILS Page 10 DRILLING CHART

More information

Polaris-I-60. active chilled beam. the future of space conditioning

Polaris-I-60. active chilled beam.   the future of space conditioning the future of space conditioning Polaris-I-60 active chilled beam Function Cooling and supply air with two-way air distribution Available with heating and integrated controls Application Offices, hotels,

More information

EASY$ TIP SHEETS. Energy Advice Saving Yukoners Money. How hydronic heating systems work

EASY$ TIP SHEETS. Energy Advice Saving Yukoners Money. How hydronic heating systems work EASY$ TIP SHEETS Energy Advice Saving Yukoners Money Quick Links How hydronic heating systems work Advantages Disadvantages Design alternatives Baseboard convectors Residential Hydronic Heating A residential

More information

Introducing LST. The low surface temperature range. dimplex.co.uk. February 2015.

Introducing LST. The low surface temperature range. dimplex.co.uk. February 2015. Introducing LST. The low surface temperature range. February 2015. dimplex.co.uk Introducing LST the intelligent commercial electric heater. Purpose designed to heat areas where vulnerable people are present.

More information

Providing Natural Solutions to Heating

Providing Natural Solutions to Heating Designed and Manufactured in Great Britain Product Range Sill-Line Perimeter Casing Warmline Trench Heating Vectair Natural and Fan Assisted Convectors Spirally Wound Gilled Tubing Providing Natural Solutions

More information

Caice Attenuator Selector - Specifier Edition

Caice Attenuator Selector - Specifier Edition Fan Coil Unit Acoustic Performance Guarantee Modular Product Selection Low Noise Levels Efficiency Energy Saving Prestige Attenuation Controls Package Plenum Heating Cooling Fan Coil Unit Acoustic Performance

More information

Space Saver. New easy guide. Connecting your Space Saver to a central heating system. Issue 001 February 2018 ENGLISH UK IRL SmithsEP.co.

Space Saver. New easy guide. Connecting your Space Saver to a central heating system. Issue 001 February 2018 ENGLISH UK IRL SmithsEP.co. Space Saver New easy guide Connecting your Space Saver to a central heating system Issue 001 February 2018 ENGLISH UK IRL SmithsEP.co.uk Issue 001 - February 2018 SmithsEP.co.uk 1 Introduction This document

More information

Aluminium Curtain Tracks

Aluminium Curtain Tracks Aluminium Curtain Tracks Hand-drawn and Corded Tracks The brand for curtain accessories The brand for curtain accessories Your Curtain Tracks and Renaissance Your time is valuable. So you need to choose

More information

Vision Air Conditioning Range Condenser-less Air Conditioner

Vision Air Conditioning Range Condenser-less Air Conditioner Powrmatic Vision 2.3 Condenser-less Air Conditioner Includes DC Inverter & Low Temperature Hot Water Models Vision Air Conditioning Range Condenser-less Air Conditioner S T Y L I S H & C O S T E F F E

More information

CASSETTE UNIT. Comfort Circle

CASSETTE UNIT. Comfort Circle CASSETTE UNIT Comfort Circle Comfort Circle cassette unit All-round comfort With today's energy prices, building owners are increasingly aware of the need for an efficient climate system to heat or cool

More information

SmartRad Planning Manual

SmartRad Planning Manual SmartRad Planning Manual Issue 1 15 April 2010 Dimplex SmartRad Fan Convector Models SRX80, SRX120, SRX140 & SRX180 Applies to models with White Glass, Black Glass and Metal facias Contents 1 Introduction

More information

WALL MOUNTED AIR CONDITIONER RANGE THE PERFECT CLIMATE.

WALL MOUNTED AIR CONDITIONER RANGE THE PERFECT CLIMATE. WALL MOUNTED AIR CONDITIONER RANGE THE PERFECT CLIMATE. 02 - The Perfect Climate Kaden Wall Mounted Air Conditioners Creating the perfect climate in your home is essential for your family s comfort. Kaden

More information

Centrifugal, tank pump designed to remove condensate water from air conditioners, refrigeration equipment, gas boilers and de-humidifiers. Engineered with contractor input and Little Giant quality, the

More information

Space Saver. New Easy Guide. Connecting your Space Saver to a central heating system BEFORE AFTER

Space Saver. New Easy Guide. Connecting your Space Saver to a central heating system BEFORE AFTER Space Saver Connecting your Space Saver to a central heating system BEFORE New Easy Guide AFTER Space Saver Introduction This document is intended as an easy step-by-step guide to connecting your Smith's

More information

The Ultimate Solution for Electric Central Heating. Fusion. Comet

The Ultimate Solution for Electric Central Heating. Fusion. Comet The Ultimate Solution for Electric Central Heating Fusion Comet Our range of Electric Boilers provide complete peace of mind for reliability, performance and safety 2 The Fusion range of electric boilers

More information

DOMESTIC HEATING CONTROLS ARE EASY PART 1 - THE BASICS

DOMESTIC HEATING CONTROLS ARE EASY PART 1 - THE BASICS DOMESTIC HEATING CONTROLS ARE EASY PART 1 - THE BASICS Today s inescapable need to improve energy efficiency in UK homes has brought installers many opportunities to make extra earnings through the upgrading

More information

Units for suspended ceilings

Units for suspended ceilings X X testregistrierung Units for suspended ceilings Type, hinged induced air grille, water connections Active chilled beam with two-way air discharge and horizontal heat exchanger, suitable for grid ceilings

More information

Recessed. Air Curtain. Fig 1. Recessed air curtain

Recessed. Air Curtain. Fig 1. Recessed air curtain the future of space conditioning recessed www.frenger.co.uk an FTF Group Company Recessed Introduction These recessed s create an air barrier, which helps to prevent cold draughts thus creating a comfortable

More information

MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR) NEW ECO RANGE

MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR) NEW ECO RANGE NEW ECO RANGE MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR) Mechanical Ventilation with Heat Recovery Proud to Build British u Nuaire is a world leader in the design and manufacture of fans and ventilation

More information

SUNWARM AIR SOLAR PRE-HEAT VENTILATION SYSTEM

SUNWARM AIR SOLAR PRE-HEAT VENTILATION SYSTEM SOLAR PRE-HEAT VENTILATION SYSTEM SUNWARM USES SOLAR ENERGY TO REDUCE THE HEATING DEMAND OF THE HOME AS WELL AS PROVIDING A COMPLETE VENTILATION SOLUTION. 76 BENEFITS Sunwarm Air provides both a ventilation

More information

The skirting board that heats your home...

The skirting board that heats your home... The skirting board that heats your home... 02 03 Benefits of using the system True radiant heat Minimal air movement and drafts create real comfort. Energy efficient Even, all-around heat uses less energy

More information

Fan heater SWT Ceiling mounted fan heater with water heat

Fan heater SWT Ceiling mounted fan heater with water heat Fan heater heat 3 models Fan heater Ceiling mounted fan heater with water heat Application The fan heater is used for heating entrances, stores, industrial premises, workshops, sports halls, garages and

More information

INTRODUCTION HOW DO RADIANT PANELS WORK? A common misconception, even among heating professionals, is that heat rises. In fact, hot air rises and cold

INTRODUCTION HOW DO RADIANT PANELS WORK? A common misconception, even among heating professionals, is that heat rises. In fact, hot air rises and cold RADIANT PANELS TRENCH PERIMETER GRILLES ELEMENTS PIPER FARM, BROMLEY GREEN ROAD, ASHFORD, KENT. TN26 2EF TEL: 01233 733308 FAX: 01233 733883 E-MAIL: sales@feukltd.com RADIANT PANEL RANGE INTRODUCTION HOW

More information

SLIM-LINE RC FAN CONVECTOR.

SLIM-LINE RC FAN CONVECTOR. SLIM-LINE RC FAN CONVECTOR. INSTALLATION, OPERATING, MAINTENANCE & AFTER SALES MANUAL Product Serial Number: Please leave this manual with the end user. Part Number: 1370064 heatingthroughinnovation. Contents

More information

DERV / ERV DEHUMIDIFICATION & ENERGY RECOVERY V E N T I L A T O R U N I T S I N N O V AT I O N W I T H S T Y L E

DERV / ERV DEHUMIDIFICATION & ENERGY RECOVERY V E N T I L A T O R U N I T S I N N O V AT I O N W I T H S T Y L E DERV / ERV DEHUMIDIFICATION & ENERGY RECOVERY V E N T I L A T O R U N I T S I N N O V AT I O N W I T H S T Y L E INTRODUCTION DERV/ERV Introduction Dehumidification & Energy Recovery Ventilator DERV units

More information

Copperad. Copperad Fan Convectors (November 2005 onwards) Installation, Operation and Maintenance Instructions To be retained by the user

Copperad. Copperad Fan Convectors (November 2005 onwards) Installation, Operation and Maintenance Instructions To be retained by the user Copperad Fan Convectors (November 2005 onwards) Installation, Operation and Maintenance Instructions To be retained by the user Copperad QA/IOM/58 Issue 2 1 GENERAL 1.1 GENERAL DESCRIPTION This manual

More information

Perimeos. Ceiling Recess. decor. systems

Perimeos. Ceiling Recess. decor. systems Ceiling Recess decor systems Ceiling Recess Perimeos is a revolutionary ceiling perimeter solution, for concealing blinds and curtain tracks. A key feature is the SpeedClip mounting channel. This allows

More information

Sargasso Range. A new range of radiant panels for heating commercial applications

Sargasso Range. A new range of radiant panels for heating commercial applications Sargasso Range A new range of radiant panels for heating commercial applications How radiant panels work Radiant panels provide heating solutions for a wide range of applications. Sargasso Radiant Panels

More information

Why our flame is so natural... Our Technology & Engineering Excellence. Efficiency. Safety & Reliability. Fully Remote Controlled

Why our flame is so natural... Our Technology & Engineering Excellence. Efficiency. Safety & Reliability. Fully Remote Controlled Why our flame is so natural... Our range of balanced flue gas stoves gives a beautiful lazy dancing flame pattern which emulates that of a traditional wood burning stove and with the added features of

More information

Panther Fan Coil Unit

Panther Fan Coil Unit Panther Fan Coil Unit Energy Efficient EC Motors 280mm Deep Chassis Horizontal Fan Coil Unit INTRODUCTION The Panther, manufactured by Dunham-Bush is an adaptable, easy to use fan coil unit, that performs

More information

Pedestal Range. Installation and user manual. Kiosk. Trafalgar. Tube. Issue 001 September 2017 ENGLISH UK IRL SmithsEP.co.uk

Pedestal Range. Installation and user manual. Kiosk. Trafalgar. Tube. Issue 001 September 2017 ENGLISH UK IRL SmithsEP.co.uk Pedestal Range Installation and user manual Kiosk Trafalgar Tube Issue 001 September 2017 ENGLISH UK IRL SmithsEP.co.uk Contents Introduction 2 Declaration of conformity 3 Symbols used in this guide 3

More information

Stainless steel range of condensing boilers. Designed to meet carbon reduction targets. Lifetime service and support. Outputs from 50kW to 660kW

Stainless steel range of condensing boilers. Designed to meet carbon reduction targets. Lifetime service and support. Outputs from 50kW to 660kW Stainless steel range of condensing boilers Outputs from 50kW to 660kW Designed to meet carbon reduction targets Lifetime service and support Totally dependable. page 1 www.pottertoncommercial.co.uk Contents

More information

QUALITAIR PACKAGED SYSTEMS & APPLIED CHILLED WATER PRODUCTS. Fan Coil Units. QCeiling Cassettes. Floor Standing Units

QUALITAIR PACKAGED SYSTEMS & APPLIED CHILLED WATER PRODUCTS. Fan Coil Units. QCeiling Cassettes. Floor Standing Units AIR CONDITIONING An air conditioned environment is increasingly expected in retail, commercial and industrial premises. Whilst there will always be a demand for custom built air conditioning the standard

More information

your comfort. our world. Altherma Flex Type Renewable heat pump system for every environment

your comfort. our world. Altherma Flex Type Renewable heat pump system for every environment your comfort. our world. Altherma Flex Type Renewable heat pump system for every environment Outdoor One or more indoor or outdoor units Indoor 1 Domestic hot water 2 Heating 3 Cooling Daikin Altherma

More information

EcoSeries S O L A R H O T WAT E R S O L U T I O N S. Ecological & Economical

EcoSeries S O L A R H O T WAT E R S O L U T I O N S. Ecological & Economical EcoSeries S O L A R H O T WAT E R S O L U T I O N S Ecological & Economical Eco friendly water heating EcoSeries Introducing the Eco-Series solar hot water system from NOBO, the low carbon, sustainable

More information

RADIANT PANELS COMMERCIAL BUILDINGS INNOVATIVE VENTILATION & HEATING

RADIANT PANELS COMMERCIAL BUILDINGS INNOVATIVE VENTILATION & HEATING RADIANT PANELS COMMERCIAL BUILDINGS A guide to Radiant Panels, including our unique product range, consultancy service and accessories. INNOVATIVE VENTILATION & HEATING www.pricetwa.co.uk FLEXIBLE, INTEGRATED

More information

DX AIR CURTAIN. SensAir

DX AIR CURTAIN. SensAir DX AIR CURTAIN SensAir Biddle and Daikin Complete climate system Since 2006 Biddle and Daikin have joined forces to provide a complete climate system for shops and public buildings. By combining Biddle

More information

WARM WATER UNDERFLOOR HEATING SYSTEMS. Guidance Notes

WARM WATER UNDERFLOOR HEATING SYSTEMS. Guidance Notes WARM WATER UNDERFLOOR HEATING SYSTEMS Guidance Notes 02 WARM WATER UNDERFLOOR HEATING SYSTEMS Introduction Underfloor heating systems consist of a series of pipes which are integrated into the floor structure

More information

Caice Attenuator Selector - Specifier Edition

Caice Attenuator Selector - Specifier Edition Fan Coil Unit Acoustic Performance Guarantee Modular Product Selection Low Noise Levels Efficiency Energy Saving Prestige Attenuation Controls Package Plenum Heating Cooling Fan Coil Unit Acoustic Performance

More information

UK PRICE GUIDE. January Complete with Technical Specifications for ROUND TOP, COMPACT, LST, AND TOWEL RADIATORS

UK PRICE GUIDE. January Complete with Technical Specifications for ROUND TOP, COMPACT, LST, AND TOWEL RADIATORS UK PRICE GUIDE January 2009 Complete with Technical Specifications for ROUND TOP, COMPACT, LST, AND TOWEL RADIATORS CONTENTS Introduction 2 Round Top Range 3 Compact Range 5 Low Surface Temperature Range

More information

JH Series Installation

JH Series Installation JH Series Installation Space Heating / Fresh Air Make-Up From the Manufacturers of Hi-Velocity Systems TM Includes: JH-15 JH-30 Module-JH-Series-Installation-Manual-010118 Installation JH fan coils by

More information

SERIES BM. Concealed Fan Convector

SERIES BM. Concealed Fan Convector SERIES BM Concealed Fan Convector Contents IDENTIFICATION Introduction Authority PAGE DESCRIPTION Range -4 Composition Features 3 Accessories 4-10 PERFORMANCE 11-13 Heat outputs-lthw Correction factors

More information

A-Class. A-Rated Homes with Dimplex heat pumps. The name you can trust. Building Regulations and Part L Compliance made easy with Dimplex. dimplex.

A-Class. A-Rated Homes with Dimplex heat pumps. The name you can trust. Building Regulations and Part L Compliance made easy with Dimplex. dimplex. A-Class A-Rated Homes with Dimplex heat pumps Building Regulations and Part L Compliance made easy with Dimplex. The name you can trust. dimplex.ie AClass A4 Page Brochure-August 2016.indd 1 A-Class Heat

More information

RADIANT PANELS COMMERCIAL BUILDINGS INNOVATIVE VENTILATION & HEATING

RADIANT PANELS COMMERCIAL BUILDINGS INNOVATIVE VENTILATION & HEATING RADIANT PANELS COMMERCIAL BUILDINGS A guide to Radiant Panels, including our unique product range, consultancy service and accessories. INNOVATIVE VENTILATION & HEATING www.pricetwa.co.uk FLEXIBLE, INTEGRATED

More information

Surface Temperature Tests on an LST Fan Convector

Surface Temperature Tests on an LST Fan Convector Surface Temperature Tests on an LST Fan Convector BSRIA Report 59569/1 Edition 2 This report supersedes Report 59569/1 dated 29 July 2016 Carried out for Smiths Environmental Products Ltd. By Alf Russell

More information

(UK) Date : February 2016 NOTE: PLEASE LEAVE COPIES OF THESE INSTRUCTIONS AND ANY DRAWINGS WITH THE END USER.

(UK)   Date : February 2016 NOTE: PLEASE LEAVE COPIES OF THESE INSTRUCTIONS AND ANY DRAWINGS WITH THE END USER. System LST Low Surface Temperature Natural Convector Installation Instructions Dunham-Bush Ltd, Downley Road, Havant, Hants PO9 2JD Tel. 023 9247 7700 Fax. 023 9245 3601 (Global) www.dunham-bush.com Document

More information

Packaged utility rooms.

Packaged utility rooms. Packaged utility rooms. Key features. The packaged utility room from Dutypoint allows developers to reduce costs, designers to save floor space and contractors to save time on site. EXTRACTION DUCT FULLY

More information

HI-LINE LV FAN CONVECTOR MODEL: 7-4.

HI-LINE LV FAN CONVECTOR MODEL: 7-4. HI-LINE LV FAN CONVECTOR MODEL: 7-4. INSTALLATION, OPERATING, MAINTENANCE & AFTER SALES MANUAL Product Serial Number: Please leave this manual with the end user. Part Number: 1370058 heatingthroughinnovation.

More information

Home owner user pack for the Nibe 200P

Home owner user pack for the Nibe 200P Home owner user pack for the Nibe 200P How to use this pack: Section 1 Please print these pages and laminate back to back to create a single document. This laminated document should be left with the Unit

More information

Powrmatic PZN / PZN-X Hot Water Heat Emitter Industrial & Commercial Heating Systems

Powrmatic PZN / PZN-X Hot Water Heat Emitter Industrial & Commercial Heating Systems Powrmatic / -X Hot Water Heat Emitter Industrial & Commercial Heating Systems www.powrmatic.co.uk +44 (0) 1460 53535 info@powrmatic.co.uk INDUSTRIAL INDUSTRIAL & COMMERCIAL & COMMERCIAL WARM HEATING AIR

More information

System 70 Datasheet/0105

System 70 Datasheet/0105 Uniclass L756 EPIC L61 CI/S/fB (56.49) x ROTEX System 70 ROTEX Environmental Management UK 2005 When specifying a ROTEX heat distribution system you are dealing with a manufacturer with over 20 years experience

More information

HOT WATER SYSTEMS.

HOT WATER SYSTEMS. HOT WATER SYSTEMS www.thermann.com.au GAS STORAGE HOT WATER SYSTEM The Thermann 4* Gas hot water heater can suit any family type. With an adjustable thermostat for safety and efficiency it allows you to

More information

Introducing the Heizen range of quality electric radiators

Introducing the Heizen range of quality electric radiators Introducing the Heizen range of quality electric radiators Contact us at: T: 0800 860 0154 E: info@powerheating.co.uk www.powerheating.co.uk facebook.com/powerheatinggb @PowerHeating1 Premium quality German

More information

Instruction Manual WARNINGS

Instruction Manual WARNINGS Instruction Manual LARGE COMMERCIAL RECESSED AIR CURTAIN HSACR9000, 12000 & 18000 ELECTRICALLY HEATED RECESSED AIR CURTAINS WITH ENERGY SAVING CONTROLS INSTALLATION AND OPERATING MANUAL INDEX Section General

More information

Installation, Operation & Maintenance Instructions Document Ref:

Installation, Operation & Maintenance Instructions Document Ref: Series AM Fan Convectors Installation, Operation & Maintenance Instructions Document Ref: Dunham-Bush Ltd, Downley Road, Havant, Hants PO9 2JD 023 9247 7700 info@dunham-bush.co.uk 121-000-001-A UK:www.dunham-bush.co.uk

More information

Sun Ray Electric Radiators Stylish, Efficient, Low Energy

Sun Ray Electric Radiators Stylish, Efficient, Low Energy Sun Ray Electric Radiators Stylish, Efficient, Low Energy RADIATOR SAVING ENERGY REDUCING THE CARBON FOOTPRINT Sun Ray Radiators are aesthetically pleasing to the Eye, Stylish, Efficient, Low Energy, Easy

More information

TRENCH HEATERS COMMERCIAL/DOMESTIC INNOVATIVE VENTILATION & HEATING

TRENCH HEATERS COMMERCIAL/DOMESTIC INNOVATIVE VENTILATION & HEATING TRENCH HEATERS COMMERCIAL/DOMESTIC A guide to Trench Heaters, including our unique product range, consultancy service and accessories. INNOVATIVE VENTILATION & HEATING www.pricetwa.co.uk OUR TRENCH HEATER

More information

Q-RAD ELECTRIC RADIATOR

Q-RAD ELECTRIC RADIATOR Q-RAD ELECTRIC RADIATOR Model QRAD150 Dubbed the electric radiator with a brain, Q-Rad monitors the effect of its actions on a room s temperature. It knows precisely how long it takes to reach the desired

More information

Sunhouse SPACE HEATING QUALITY STYLE VALUE

Sunhouse SPACE HEATING QUALITY STYLE VALUE SPACE HEATING QUALITY STYLE VALUE Quality Style 2 Value is our long established brand of heating products that has always given exceptional quality and reliability for the best value! Our range combines

More information

Chrome. Approximately 26 seconds drying time. 1.0kW Automatic Eco Fast Dryer Epoxy Coated. 1.2mm thick steel cover

Chrome. Approximately 26 seconds drying time. 1.0kW Automatic Eco Fast Dryer Epoxy Coated. 1.2mm thick steel cover Automatic & Manual Hand dryers for Commercial Applications 1.1kW Compact Eco Swift 409733 409734 Satin Stainless Steel 409735 Polished Stainless Steel Intelligent sensing, element auto switch off when

More information

Series CM. Cased fan convector Sill-Line 600mm high 7 sizes and 3 heating coil options 1-13kW output with LPHW C heating medium

Series CM. Cased fan convector Sill-Line 600mm high 7 sizes and 3 heating coil options 1-13kW output with LPHW C heating medium Series CM Cased fan convector Sill-Line 6mm high 7 sizes and 3 heating coil options 1-13kW output with LPHW 5-13 C heating medium CONTENTS IDENTIFICATION Identification Introduction 2 Authority 2 Description

More information

CREATING A HEALTHY INDOOR ENVIRONMENT POSITIVE INPUT VENTILATION (PIV)

CREATING A HEALTHY INDOOR ENVIRONMENT POSITIVE INPUT VENTILATION (PIV) CREATING A HEALTHY INDOOR ENVIRONMENT POSITIVE INPUT VENTILATION (PIV) NUAIRE S PEDIGREE Proud to Build British Nuaire is a world leader in the design and manufacture of fans and ventilation systems. We

More information

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support Aluminium range of condensing boilers Outputs from 30kW to 600kW Designed to meet carbon reduction targets Lifetime service and support Works every time. www.pottertoncommercial.co.uk Aluminium range of

More information

AquaCyl solar system solar water heating solution for the larger home with greater hot water demand (2 or more bathrooms in use simultaneously)

AquaCyl solar system solar water heating solution for the larger home with greater hot water demand (2 or more bathrooms in use simultaneously) AquaCyl solar system solar water heating solution for the larger home with greater hot water demand (2 or more bathrooms in use simultaneously) solar collector AquaCyl cylinder system boiler Making life

More information

CI/SfB X. RHeco Series CONDENSING GAS FIRED UNIT HEATERS

CI/SfB X. RHeco Series CONDENSING GAS FIRED UNIT HEATERS CI/SfB 56.83 X RHeco Series CONDENSING GAS FIRED UNIT HEATERS RHeco Series CONDENSING GAS FIRED UNIT HEATERS Introduction Features & Benefits Model Range Reznor continue their tradition of manufacturing

More information

The easy solution for waste water removal

The easy solution for waste water removal The easy solution for waste water removal Wasteflo products provide a solution for waste water removal in a variety of environments. Full technical data sheets are available to download www.stuart-turner.co.uk

More information

Energy-efficient heat source provides comfort in large rooms

Energy-efficient heat source provides comfort in large rooms AIR HEATER NOZ NOZ air heater Energy-efficient heat source provides comfort in large rooms When it comes to providing large, and often high buildings, with the best possible source of efficient heating

More information

VD 3401 Chauffage central Installation, Operating, Maintenance and After Sales Manual

VD 3401 Chauffage central Installation, Operating, Maintenance and After Sales Manual VD 3401 Chauffage central Installation, Operating, Maintenance and After Sales Manual INDEX 1 General information 3 2 Heating system design 3 3 Selection and Sizing for heating 3 4 Location 3 5 Preparation

More information

thermocompact High performance system boiler range

thermocompact High performance system boiler range thermocompact High performance system boiler range Built-in performance The expectations of today s system boiler have never been more demanding, which is why Vaillant s thermocompact range comes with

More information

Saving energy comes naturally to us.

Saving energy comes naturally to us. Domestic Heat Pumps Saving energy comes naturally to us. Low carbon solutions for heating and hot water The sustainable heating solution for today and tomorrow Home heating with lashings of hot water Whether

More information

Enriching Environments

Enriching Environments Enriching Environments 2 Enriching Environments We understand the difference an improved internal environment can make 3 Contents 4 5 6 7 8 9 10 11 About us Heating and cooling coils Fan convectors Trench

More information

HI-LINE SUPER RC FAN CONVECTOR MODELS: 25-18,

HI-LINE SUPER RC FAN CONVECTOR MODELS: 25-18, HI-LINE SUPER RC FAN CONVECTOR MODELS: 25-18, 29-20. INSTALLATION, OPERATING, MAINTENANCE & AFTER SALES MANUAL Product Serial Number: Please leave this manual with the end user. Part Number: 1370065 heatingthroughinnovation.

More information

Commercial Evaporative Cooling

Commercial Evaporative Cooling Commercial Evaporative Cooling The Bonaire System Advantage Bonaire has been providing innovative commercial evaporative cooling solutions for over 60 years on projects with applications which have been

More information

Panel Radiators. Installation and operating instructions. ThermaRad Classic.

Panel Radiators. Installation and operating instructions.   ThermaRad Classic. ThermaRad Hurlcon Panel Radiators Installation and operating instructions ThermaRad Classic ThermaDesign ThermaStyle www.hurlconheating.com.au enquiries@hurlconheating.com.au Melbourne: 03 9554 2275 Sydney:

More information

Type CODE Speed Heating Cooling

Type CODE Speed Heating Cooling CLIMA CANAL HYBRID - Low Temperature radiator - Heating and cooling - Build-in height of 10 > 14.5 cm CLIMA CANAL - Low Temperature radiator - Heating - Build-in height of 8.5 > 13 cm 24V EC MOTOR High

More information

KICKSPACE 500, 600, V & 800

KICKSPACE 500, 600, V & 800 MYSON Eastern Avenue, Team Valley, Gateshead, Tyne & Wear NE11 0PG, UK T: 0845 402 3434, F: 0191 491 7568, sales@myson.co.uk, www.myson.co.uk Installation, Operating, Maintenance and After Sales Manual.

More information

Colt CoolStream Adiabatic Cooling & Ventilation System

Colt CoolStream Adiabatic Cooling & Ventilation System Colt CoolStream Adiabatic Cooling & Ventilation System Colt CoolStream Adiabatic Cooling & Ventilation System Colt coolstream Adiabatic cooling & ventilation system DESCRIPTION Colt CoolStream is a natural

More information

MRXBOXAB-ECO-LP1 100% Typical Installation. (including opposite handed versions)

MRXBOXAB-ECO-LP1 100% Typical Installation. (including opposite handed versions) NUAIRE MVHR (including opposite handed versions) ACHIEVES 100% DUTY IN BYPASS MODE and MRXBOXAB- ECO-LP1-OH are specically designed for apartment applications where space is a premium. The new MRXBOX95-LP1

More information

High temperature air-to-water heat pumps

High temperature air-to-water heat pumps Designed to replace conventional boilers and produce domestic hot water 4 High temperature hot water (+65 C) 4 Winter operation (-20 C) 4 High energy efficiency (CP) 4 Compact and quiet 4 Scroll compressors

More information

3RD GENERATION PANEL RADIATOR

3RD GENERATION PANEL RADIATOR 3RD GENERATION PANEL RADIATOR HIGHEST HEAT OUTPUT LOWEST RUNNING COST SMALLEST CARBON FOOTPRINT NI - April 2018 02 CONTENT Why choosing QRL Radiator Group? 01 The Future of Radiators, Today 02-03 HI-LO

More information

UniTrane Terminals. High Wall Fan Coil: W-Line Ducted Fan Coil: D-Line Blower coil: B-Line. Product Presentation September 2016

UniTrane Terminals. High Wall Fan Coil: W-Line Ducted Fan Coil: D-Line Blower coil: B-Line. Product Presentation September 2016 UniTrane Terminals High Wall Fan Coil: W-Line Ducted Fan Coil: D-Line Blower coil: B-Line Product Presentation September 2016 Agenda Product overview Key features Product range Controls Emissions Accessories

More information

Safe Heating in Sheltered and Social Housing

Safe Heating in Sheltered and Social Housing Safe Heating in Sheltered and Social Housing Introduction Specification of heat emitters for sheltered housing and social housing needs to take account of the needs of the residents of these premises,

More information

HEATXL RVS. Electric Infrared Heater

HEATXL RVS. Electric Infrared Heater HEATXL RVS Electric Infrared Heater HeatXL RVS Heater is an all-round, supplementary or overall heater for conservatories, balconies, patios and is also effective as a spot/zone heater in workshops, warehouses

More information

HDG K SERIES. Wood pellet boiler. The perfect alternative to fossil fuels. Receive up to

HDG K SERIES. Wood pellet boiler.   The perfect alternative to fossil fuels. Receive up to (56.81) April 2013 Receive up to 2635 RHI back every year for the next seven years HDG K SERIES Wood pellet boiler The perfect alternative to fossil fuels www.euroheat.co.uk The K Series pellet boiler,

More information

Warm Air Central Heating

Warm Air Central Heating Warm Air Central Heating WarmCair Condensing Economaire Hi-Spec www.johnsonandstarley.co.uk As market leaders and innovators, Johnson & Starley have increasingly specialised in domestic heating. We helped

More information

Elegant design with the high performance heating technology of tomorrow - today. Electric Combination Radiator Systems Elektroheizung GmbH & Co.

Elegant design with the high performance heating technology of tomorrow - today. Electric Combination Radiator Systems Elektroheizung GmbH & Co. Elegant design with the high performance heating technology of tomorrow - today Electric Combination Radiator Systems Elektroheizung GmbH & Co. KG A n e l e g a n t s o l u t i o n f o r a l l h e a t

More information

Optimal work climate with open doors. Industrial air curtains Model IndAC

Optimal work climate with open doors. Industrial air curtains Model IndAC Optimal work climate with open doors Industrial air curtains Model IndAC Industrial air curtain Optimal work climate During loading and unloading the door remains open, without the indoor climate being

More information

Halton Rex 600 Basic R6B - Active chilled beam

Halton Rex 600 Basic R6B - Active chilled beam Halton Rex 600 Basic R6B - Active chilled beam Halton Rex 600 Basic chilled beam is: A base version to the combined cooling, heating, and supply air unit for flush installation within a suspended ceiling.

More information

KLIMA Active Chilled Beams

KLIMA Active Chilled Beams KLIMA 2 600 Active Chilled Beams Index Subject Page Index 1 Introduction 2 General description 3-4 Product features 5-6 Dimensions 7 Performance data 8-11 Section example Guide specifications 13 1 Introduction

More information

Original instructions AR

Original instructions AR Original instructions SE... 8 GB... 22 NO... 27 FR... DE... 6 ES... 4 NL... 46 IT... 5 RU... 56 Dimensions and connections AR20/AR25 M8 002/52 940/450 494 449 92 20 98 042/552 42 20 AR20/25A/E 40 275 DN5

More information

Amptec. Electric flow boiler

Amptec. Electric flow boiler Amptec Electric flow boiler the nation s favourite for PLUMBING & HEATING SUPPLIES FREE SHIPPING on all orders over 100 to mainland UK FINANCE AVAILABLE spread the cost with low interest rates SECURE PAYMENTS

More information