Standard Tank One (Approximately 1500 gallons)
|
|
- Victoria Robertson
- 5 years ago
- Views:
Transcription
1 Standard Tank One (Approximately 1500 gallons) 11' 0" 6" PVC tee Cap / Clean out From Bay Drain See Note 2 1-1/4 Ozone return Line, terminate with a tee 6 Tee 6 PVC To Tank Two See Note 3 6 Transfer 5' 2" 3' 0" Standard Tank One 6' 0" (Approximately 1,500 Gallons) Hole 1 - The Tank Dimensions will vary slightly depending on location. It is important to keep the Tank capacity approximately 1500 gallons and piping layout as close to the above dimensions as possible. Hole 2 - The 6 line from the wash bay should terminate just inside the tank wall with a PVC Tee. This will reduce turbulence in the Grease & Oil Trap option of Tank One. Hole 3 - Ozone return line should enter tank one approximately at the mid section of Tank wall and extend down into the tank approximately 3 (foot). Then Terminate the 1-1/4 Ozone Pipe with a 1-1/4 PVC Tee. This will distribute the Ozone Bubbles towards the entrance and exit of Tank One.
2 Standard Tank Three (Approximately 1500 gallons) Notes for Suction Lines: For all standard filtration Systems we strongly recommend two SCH 80 PVC 2 pipes with SCH 80 PVC pipe fittings. Lines should be approximately 16 off the tank floor and plumbed to the recovery unit using the most direct route and avoiding as many 90 degree turns as possible. Pipe fittings should be cleaned and secured together using only the SCH 80 PVC recommended cleaner and adhesive. Use the Standard Stub Up drawing to have the pipe protrude through the slab at the appropriate position on the recovery equipment. (See Plumbing Stub Up) 11' 0" From Tank Two 6 PVC Tee 5' 1" Sewer Overflow If Available Standard Tank Three ( Approximately 1,500 Gallons ) 5' 2" Suction Lines See Notes 6.0 1' 4 Note for (3 ) three inch option equipment. For all optional high volume systems with 3 plumbing be sure to substitute three inch SCH 80 suction lines for the two standard 2 lines that are normally shown in most Filtration drawings. We STRONGLY recommend 3 Option Equipment to be used in applications where demand for reclaimed water is going to be above 70 GPM.
3 Typical Tank Dimensions Notes for SUCTION LINES: For all standard filtration systems we strongly recommend two SCH 80 PVC 2" pipe fittings. Lines should be approximately 16" off the tank floor and plumbed to the recovery unit using the most direct route and avoiding as many 90 degree turns as possible. Pipe fittings should be cleaned and secured together using only the SCH 80 PVC recommended cleaner and adhesive. Use the standard stub up drawing to have the pipe protrude through the slab at the appropriate position on the recovery equipment. (See plumbing Stub Up) * Note for THREE INCH (3") OPTION EQUIPMENT: For all optional high volume systems with 3" plumbing, be sure to substitute three inch (3") SCH 80 suction lines for the two standard 2" lines that are normally shown in most filtration drawings. We STRONGLY recommend 3" option equipment to be used in applications where demand for reclaimed water is going to be above 70 GPM.
4 Typical Tank Dimensions Notes for SUCTION LINES: For all standard filtration systems we strongly recommend two SCH 80 PVC 2" pipe fittings. Lines should be approximately 16" off the tank floor and plumbed to the recovery unit using the most direct route and avoiding as many 90 degree turns as possible. Pipe fittings should be cleaned and secured together using only the SCH 80 PVC recommended cleaner and adhesive. Use the standard stub up drawing to have the pipe protrude through the slab at the appropriate position on the recovery equipment. (See plumbing Stub Up) * Note for THREE INCH (3") OPTION EQUIPMENT: For all optional high volume systems with 3" plumbing, be sure to substitute three inch (3") SCH 80 suction lines for the two standard 2" lines that are normally shown in most filtration drawings. We STRONGLY recommend 3" option equipment to be used in applications where demand for reclaimed water is going to be above 70 GPM.
5 VERTICAL TANKS Larger Tanks and Installation of Custom Fittings Available: -Float Balls - Bulk Head Fittings CALL FOR QUOTE! 165 Gallon Vertical Tank (31 d x 57 h w/con-serv Logo)...$ Gallon Vertical Tank (31 d x 57 h w/con-serv Logo)...$ Gallon Vertical Tank (35 d x 76 h w/con-serv Logo)....$ Gallon Vertical Tank (43 d x 72 h w/con-serv Logo)....$ Gallon Vertical Tank (47 d x 71 h w/con-serv Logo)....$ Gallon Vertical Tank (47 d x 102 h w/con-serv Logo)..$ 1, Gallon Vertical Tank (47 d x 114 h w/con-serv Logo)..$ 1, West Brannen Road, Lakeland, FL * * Fax *
6 In Stock or Custom Built to your specifications! Save Time and Money on costly Site Installations! Re-Pressurization / R.O. Systems, Pre-Plumbed and Pre-Wired Tanks The following systems are pre-build for fast easy installation includes; Tank Stainless Pump, Float Level Control, Pressure Switch, Ballast Tank ready for plug and go installation. The Stainless pumps offer lbs of pressure and flow rates of 10/20/30 GPM. Additional pumps can be installed for multidistribution applications. Tank Size 10 GPM 20 GPM. 30 GPM. 165 Gallon $ 1,890 $ 1,990 $ 2, Gallon $ 2,190 $ 2,290 $ 2, Gallon $ 2,390 $ 2,490 $ 2, Gallon $ 2,690 $ 2,790 $ 2,890 Additional Pumping Stations $ 920 For 20 GPM Pump Station add $ 990 For 30 GPM Pump Station add $ 1,100 CON-SERV SPECIALIZES IN RE-PRESSURIZATION SYSTEMS Many Other Tank Sizes Are Available! Call for Pricing. Reject Re-Pressurization Systems Pre-Plumbed and Pre-wired same pricing as above. (This feature automatically blends R.O. Reject and City Water to reservoir that can be used for any Fresh Water Application) Some. Features of Pre-Assembled Tanks * Two or more pumps can be installed inside the tank to handle Multiple Bays, Arches, Chemical Feed, Spritzer Window Cleaning, and will allow more flexible sequencing in Glass Buildings * Multiple Small Pumps offer a reliable more efficient method of dispensing Spot-Free or ROR Reject Water Typical layout incorporating the use of R.O. & R.O. reject water for additional savings. 605 West Brannen Road, Lakeland, FL (800) Fax (863)
Construction and Installation Instructions For the A&A Splash Pad
Construction and Installation Instructions For the A&A Splash Pad Revised 9//09 These instructions are not meant to be detailed construction plans since you will be using your standard plumbing and deck
More information26/06/2018 USER MANUAL HOBBY 100 GPH REVERSE OSMOSIS. All Rights reserved Les Équipements d Érablière CDL inc.
26/06/2018 USER MANUAL HOBBY 100 GPH REVERSE OSMOSIS All Rights reserved Les Équipements d Érablière CDL inc. Thank you for purchasing a CDL Hobby reverse osmosis system. This document will help you make
More informationInstall Configurations
Table of Contents EQUIPMENT SPECS: 1 WATER SUPPLY CONFIGURATIONS 2 OPTION 1 (OPTIMIZED): BRING WATER TO MACHINES 2 OPTION 2 (ENHANCED): INSTALLING A DEDICATED WATER SOURCE 3 OPTION 3 (ENHANCED CONT.):
More information26/06/2018 USER MANUAL OSMOSE HOBBY GPH. All rights reserved Les Équipements d Érablière CDL inc.
26/06/2018 USER MANUAL OSMOSE HOBBY 100-200 GPH All rights reserved Les Équipements d Érablière CDL inc. Thank you for purchasing a CDL Hobby reverse osmosis system. This document will help you make the
More informationTechnical Specifications & Pricing
Nu/Clean Model 510 Recirculating Water Deionizer Inline Aqueous Cleaning System for Closed Loop, Zero Discharge Operations Technical Specifications & Pricing The base machine in its standard configuration
More informationEXTREME 1 Reverse Osmosis System
EXTREME 1 Reverse Osmosis System Leader Evaporator Co., Inc. 49 Jonergin Drive Swanton, VT 05488 Tel: 802-868-5444 www.leaderevaporator.com TABLE OF CONTENTS INTRODUCTION... 4 THEORY OF OPERATION... 4
More informationEXTREME HP-1 Reverse Osmosis System
EXTREME HP-1 Reverse Osmosis System Leader Evaporator Co., Inc. 49 Jonergin Drive Swanton, VT 05488 Tel: 802-868-5444 www.leaderevaporator.com TABLE OF CONTENTS INTRODUCTION... 4 THEORY OF OPERATION...
More informationREVERSE OSMOSIS SYSTEMS
REVERSE OSMOSIS SYSTEMS TABLE OF CONTENTS R.O. SYSTEM DESCRIPTION... 2 R.O. EQUIPMENT INSTALLATION...3 R.O. SYSTEM CHECK-OUT PROCEDURE... 4 R.O. UNIT TURN ON PROCEDURE...5 R.O. UNIT RATING.. 6 R.O. BAY
More informationCasey Craft
SmartWash Locomotive Wash Whiting Systems, Inc. 9000 Highway 5 North Alexander, Arkansas 72002 800-542-9031 501-847-0074 fax Casey Craft cc@rmsi.net 1 Whiting Systems, Inc. 9000 Highway 5 North Alexander,
More informationEXTREME HC-4 Reverse Osmosis System Leader Evaporator Co., Inc. 49 Jonergin Drive Swanton, VT Tel:
[Type a quote from the document or the summary of an interesting point. You can position the text box anywhere in the document. Use the Drawing Tools tab to change the formatting of the pull quote text
More informationWM-450-PT WM-900-PT Commercial Wall Mounted Reverse Osmosis
WM-450-PT WM-900-PT Commercial Wall Mounted Reverse Osmosis Installation And Service Manual Watts Pure Water 1725 W. Williams Dr. C-20., Phoenix, Arizona 85027 Phone: 888-774-7405 Fax: 602-588-0356 www.wattspurewater.com
More informationStormwater Vortex Clarifier Project Build Instructions
Stormwater Vortex Clarifier Skim drain Separates bulk solids that sink or float $45 PARTS COMPONENT QTY SOURCE PURPOSE 55 gal drum 1 Local reclaim Tank Banjo 1.5" bulkhead 2 Amazon.com Fill & Drain 1.5"
More informationFleck 2510 SXT Catalox Installation & Start Up Guide
Fleck 2510 SXT Catalox Installation & Start Up Guide For Catalox Filters with PotPerm Bleach Solution Tank Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance
More information7800 Neutralizer Installation & Start-Up Guide
Clean Water Made Easy www.cleanwaterstore.com 7800 Neutralizer Installation & Start-Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance your
More informationOPERATING MANUAL. Reverse Osmosis Equipment Model: Frame Mount Vertical FMV-1 through FMV-6. Made in U.S.A.
OPERATING MANUAL Reverse Osmosis Equipment Model: Frame Mount Vertical FMV-1 through FMV-6 Made in U.S.A. TABLE OF CONTENTS Model: Frame Mount Vertical COMPONENT IDENTIFICATION Page 1 IMAGE OF R. O. SYSTEM
More informationEXTREME 2 Reverse Osmosis System
EXTREME 2 Reverse Osmosis System Leader Evaporator Co., Inc. 49 Jonergin Drive Swanton, VT 05488 Tel: 802-868-5444 www.leaderevaporator.com TABLE OF CONTENTS INTRODUCTION... 4 THEORY OF OPERATION... 4
More informationEXTREME HC-8 Reverse Osmosis System
EXTREME HC-8 Reverse Osmosis System Leader Evaporator Co., Inc. 49 Jonergin Drive Swanton, VT 05488 Tel: 802-868-5444 www.leaderevaporator.com TABLE OF CONTENTS INTRODUCTION... 4 THEORY OF OPERATION...
More informationLubrication Tools and Equipment Portable Oil Drains
Portable Oil Drains Choose the fluid handling equipment that fits your needs. Traditional Drain: the traditional method for handling used fluids allows gravity to drain fluids from vehicle(s) into a portable
More informationEXTREME HC-2 Reverse Osmosis System
EXTREME HC-2 Reverse Osmosis System Leader Evaporator Co., Inc. 49 Jonergin Drive Swanton, VT 05488 Tel: 802-868-5444 www.leaderevaporator.com Contents INTRODUCTION... 3 THEORY OF OPERATION... 4 Terms...
More informationirritec USA irritec USA THE MODULAR SAND MEDIA FILTER TM Water Tool Filters
irritec WWW.IRRITEC.COM The Modular Sand Media Filter is an advanced filtration system, designed from the ground up, especially for media filtration, to provide the ultimate Sand Media Filter. Each Modular
More informationHID312, HID525 and HID540 Meridian Ice Maker-Dispensers Technical Service
HID312, HID525 and HID540 Meridian Ice Maker-Dispensers Technical Service What you will learn Introduction Installation Operation Maintenance Take It Apart Diagnostics HID Ice Maker-Dispensers HID models
More informationTeak Self-Watering Square Planter
Teak Self-Watering Square Planter Strength, durability and natural weather resistance have made teak the wood of choice for generations of builders and craftsmen. Our friends at Reforest Teak make these
More informationTable of Contents. List of Figures
1 P a g e Table of Contents Introduction. 3 Receiving....4 Description Model G3 & G4...5/6 Water Production Flow Chart...7 Positioning the Cooler...8 Water Cooler Connections..9 Feed Water Connection....10
More informationEquipment Alert. P-Trap Must Be Installed to Exhaust or Warranty will be Voided. Refer to this Manual for installation Instructions
Dry Assembled Elbows MUST Glue when Installed Exhaust Connection P-Trap Must Be Installed to Exhaust or Warranty will be Voided AA2360 Refer to this Manual for installation Instructions 2011 Midmark Corp.
More informationINSTALLATION & SERVICE MANUAL
INSTALLATION & SERVICE MANUAL Countertop Reverse Osmosis Systems Series CT CT-315 CT-315TFC CT-445 CT-445P CT-D425 CT-D425P CT-550UP 3 STAGE CTA RO SYSTEM 3 STAGE TFC RO SYSTEM 4 STAGE TFC RO SYSTEM 4
More informationClean Water Made Easy
Clean Water Made Easy www.cleanwaterstore.com CWS Plus Neutralizer/Birm Blend Installation & Start-Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine
More information1 P a g e. G4 Counter Top OPERATION MANUAL
1 P a g e G4 Counter Top OPERATION MANUAL Table of Contents Introduction. 3 Receiving....4 Description Model G3 & G4...5/6 Water Production Flow Chart...7 Positioning the Cooler...8 Water Cooler Connections..9
More informationInstallation and User's Manual for Flake and Nugget Ice Machine. Models FME504, FME804, NME454, NME654
Installation and User's Manual for Flake and Nugget Ice Machine Models FME504, FME804, NME454, NME654 INTRODUCTION To the owner or user: This manual is intended to provide you with the information needed
More informationFREESTANDING ACRYLIC TUB INSTRUCTION MANUAL
FREESTANDING ACRYLIC TUB INSTRUCTION MANUAL HELIXBATH FREESTANDING ACRYLIC TUB GENERAL INSTALLATION INSTRUCTIONS & CARE GUIDE Before you begin installing your new Helixbath freestanding tub we recommend
More informationOwner s Manual Therma-Stor II Heat Recovery System
PO Box 8680 Madison, WI 53708 TS-138C Revised 8/08 Owner s Manual Therma-Stor II Heat Recovery System Installation, Operation & Service Instructions Read and Save These Instructions Table Of Contents 1.
More informationPIONEERS IN AIR VACUUMS
PIONEERS IN AIR VACUUMS SINCE 1947 Rema Dri-Vac Corp. 45 Ruby Street Norwalk, CT 06850 Phone: 203-847-2464 Fax: 203-847-3609 Email: info@remadrivac.com WWW.REMADRIVAC.COM AIR VACUUMS RETURN SYSTEMS BURK
More informationPolyMax H2-24 Dutch Bucket System
11234 PolyMax H2-24 Dutch Bucket System *Actual system may differ. PolyMax Dutch Buckets Versatile PolyMax Dutch Buckets are ideal for both small- and large-scale hydroponic growing. 2017 FarmTek All Rights
More informationClearFire Economizer Model ECF Integral or External. Addendum to manuals CFH and CFV
ClearFire Economizer Model ECF Integral or External Addendum to manuals 750-295 CFH and 750-269 CFV CB-8466 08/2011 1-GENERAL The Model ECF economizer is a stainless steel coil tube arrangement using
More information5900e Greensand Filter Installation & Start-Up Guide
Clean Water Made Easy www.cleanwaterstore.com 5900e Greensand Filter Installation & Start-Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance
More informationJob #22 AS-BUILT ALL DIMENSIONS SUBJECT TO 1/4" TOLERANCES
SPECIFICATIONS SHELL WEIGHT: 3000 LBS. 10'-11" O.D. 10'-2 1/2" O.D. 8'-6" I.D. 6'-11 1/2" Job #22 WATER WEIGHT: 5656 LBS. TOTAL SHELL & 8656.1 LBS. WATER WEIGHT: WATER VOLUME: 90.7 Cu.Ft. R5'-1 1/4" WATER
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS Series Units RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE WARNING Improper installation, adjustment, alteration, service or maintenance can cause personal injury, loss of life,
More informationMULTI FLOW HYDROPONIC SYSTEM
MULTI FLOW HYDROPONIC SYSTEM Thank you for purchasing the Multi Flow Hydroponic System. The Multi Flow is an ebb and flow or fill and drain type hydroponic system. The operation is simple, the pots are
More informationClean Water Made Easy
Clean Water Made Easy http://www.cleanwaterstore.com Pro-OX 2510 Iron Filter Installation & Start- Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine
More informationDansereau Dental. P r e - C o n s t r u c t i o n G u i d e
P r e - C o n s t r u c t i o n G u i d e 2 0 1 4 A m e r i c a s D e n t a l E q u i p m e n t C o m p a n y Dansereau Dental (800) 423-5657 / WWW.DHPDENTAL.COM M a n u fa c t u r e d i n U S A f o r
More informationKey Factors in Selecting a Suitable Web Cleaning System
Key Factors in Selecting a Suitable Web Cleaning System Presented By: Matt Fyffe Product shown in this document may be covered by one or more patents, patents applied for and/or registered designs and/or
More informationIron Air Charge MangOx 2510 SXT Installation & Start Up Guide
Iron Air Charge MangOx 2510 SXT Installation & Start Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance your system will be providing iron
More informationEXTREME 4 Reverse Osmosis System
EXTREME 4 Reverse Osmosis System Leader Evaporator Co., Inc. 49 Jonergin Drive Swanton, VT 05488 Tel: 802-868-5444 www.leaderevaporator.com TABLE OF CONTENTS INTRODUCTION... 4 THEORY OF OPERATION... 4
More informationInstitutional Laundry & Warewash Solutions
Institutional Laundry & Warewash Solutions Clean n Bright n Fresh Clean, Safe, Healthy Facilities - Lowest Total Cost Proven Chemistry Dependable Dispensing Technical Expertise Exceptional Service We Understand
More informationJ-PRO V 230V Dual Voltage Hydrogen Peroxide Pump Installation & Start-Up Guide
J-PRO-22 110V 230V Dual Voltage Hydrogen Peroxide Pump Installation & Start-Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance, your system
More information2016 Plumbing Supplemental Plan Review List
Building Division 555 Santa Clara Street Vallejo CA 94590 707.648.4374 2016 Plumbing Supplemental Plan Review List POTABLE WATER SYSTEM P1. Specify which fixtures are for private use and which are for
More informationInstallation and Operation Manual. ACF-18 Automatic Chlorinating Feeder
Installation and Operation Manual ACF-18 Automatic Chlorinating Feeder Operating Specifications Inlet Flow: 1.0-1.5 gpm Outlet Flow: = Inlet Flow Inlet Pressure: 10-45 psi Maximum Output: 26 lbs. of Available
More informationClean Water Made Easy
Clean Water Made Easy http://www.cleanwaterstore.com Pro-OX 1650 Iron Filter Installation & Start-Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance
More informationUltraviolet Systems UV-C 50 INSTALLATION INSTRUCTIONS & PRODUCT MANUAL
Ultraviolet Systems Inc. UV-C 50 INSTALLATION INSTRUCTIONS & PRODUCT MANUAL TABLE OF CONTENTS SECTION 1 General Information 1A. Description...1 1B. Specifications...1 SECTION 2 Installation 2A. Pool Preparation...
More informationEcoMaster - Residential Pools up to 40,000 Gallons
- Residential Pools up to 40,000 Gallons INSTALLATION/ OPERATION GUIDE Reduces Chemical Usage, Improves Sanitation Produces Crystal Clear Water Copyright 2013 Prozone Water Products: 3004 11 th Ave. -
More information4. TECHNOLOGY AND DESIGN CRITERIA
4. TECHNOLOGY AND DESIGN CRITERIA 12 Current FOG pretreatment technology typically takes the form of smaller, metal, grease-handling devices found in the kitchen area of the facility; or large, in-ground,
More information4201 Lien Rd Madison, WI Owner s Manual Therma-Stor III Heat Recovery System. Installation, Operation & Service Instructions
4201 Lien Rd Madison, WI 53704 TS-140F Revised 09-10 Owner s Manual Therma-Stor III Heat Recovery System Installation, Operation & Service Instructions Read and Save These Instructions Table Of Contents
More informationSpot Free Reverse Osmosis Rinse System
Spot Free Reverse Osmosis Rinse System CONTENTS 2016 TOMMY CAR WASH SYSTEMS General Instructions... 2 Overview of RO System... 2 Key Reverse Osmosis System Terms... 5 Requirements... 8 Feed Water Pre-treatment
More information1 Exam Prep Plumber s Handbook Tabs and Highlights
1 Exam Prep Plumber s Handbook Tabs and Highlights These 1 Exam Prep Tabs are based on the Plumber s Handbook Revised 2006. Each Tabs sheet has five rows of tabs. Start with the first tab at the first
More informationCascade Premier and Elite Premier Bathing Systems with Aqua-Aire Installation / Assembly Instructions
Cascade Premier and Elite Premier Bathing Systems with Aqua-Aire Installation / Assembly Instructions Premier Elite Premier PENNER PATIENT CARE, INC Box 523 / 102 Grant St. Aurora, NE 68818 360745P Revision
More informationSERVICE REQUIREMENTS
SERVICE REQUIREMENTS WARNING! Read and understand the contents of this manual before attempting to service WL400. Failure to follow the instructions in this manual could result in death, serious personal
More informationOPERATING and SERVICE GUIDE USA - Coin in / Ticket out Feature.
OPERATING and SERVICE GUIDE USA - Coin in / Ticket out Feature. Produced by ; Harry Levy Amusement Contractor Ltd Unit 6 Patricia Way Pysons Road Industrial Estate Broadstairs Kent CT10 2LF Tel 01843 866
More informationINSTALLATION INSTRUCTIONS GEO PRIME TANK. (Patent Pending) GPC
INSTALLATION INSTRUCTIONS GEO PRIME TANK (Patent Pending) GPC Table of Contents General Description 2 Installation 3 Flushing and Purging 5 Initial Start up 7 Adding or Checking Fluid 8 Replacing a Pump
More informationUsed Fluid Handling Portable Used-Oil Gravity Drains
Portable Used-Oil Gravity Drains Choose the fluid handling equipment that fits your needs. Traditional Drain: the traditional method for handling used fluids allows gravity to drain fluids from vehicle(s)
More informationStandard Features. Performance/Capacities
TSC-66 Traditional Power/Connections Approximate Total Load AMPS 208V / 60HZ / 3PH 51.8 208V / 60HZ / 1PH 88.3 230V / 60HZ / 3PH 47.8 230V / 60HZ / 1PH 81.5 460V / 60HZ / 3PH 23.9 Booster Heater Options
More informationDual Tank Bicarb-Short Profile Central Mix and Delivery Installation Manual
Better Water LLC Dual Tank Bicarb-Short Profile Central Mix and Delivery rev. Jun 2017 REA 2346 Better Water LLC. All rights reserved. The content of this manual is the intellectual property of Better
More informationGT Water Products, Inc.
GT Water Products, Inc. 1. WWW.GTWATERPRODUCTS.COM GT Water Products Inc. GT Water Products Inc. - Product Presentation Company Profile Test Plugs Drain King Mini Snake Drain Cleaner Master Plunger 2 GT
More informationOzone System Maintenance Instructions
Ozone System Maintenance Instructions Congratulations on your purchase. If you have any questions please call. Regular cleaning of your system's filter and diffuser is important to keep your system operating
More information1-866-PENNERS
Cascade Premier and Elite Premier Bathing Systems with Aqua-Aire Installation / Assembly Instructions Premier Elite Premier PENNER PATIENT CARE, INC Box 523 / 102 Grant St. Aurora, NE 68818 360745P Revision
More information5900e Neutralizer Installation & Start Up Guide
Clean Water Made Easy www.cleanwaterstore.com 5900e Neutralizer Installation & Start Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance your
More informationINSTRUCTION MANUAL. Blue Whale Spa Ltd, 11 Glaisdale Drive East Nottingham, NG8 4GU
INSTRUCTION MANUAL Balboa 500Z-Series Operation Guide Initial Start-up Your spa will enter Priming Mode ( ) when it is energized. During Priming Mode, press Jets button(s) repeatedly and be sure all pumps
More informationWARRANTY POLICY & RECOMMENDED MAINTENANCE
WARRANTY POLICY & RECOMMENDED MAINTENANCE WARRANTY POLICY The following information will explain the plumbing components and warranty coverage for the plumbing systems and fixtures in your new home. It
More informationL.A.S. Associates/FAIM Reps, LLC
the CHILLTECH SERIES www.systemsiv.com The EXCLUSIVE ChillTech Heat Exchange system lowers water temperature to incoming ice makers. This results in significantly reduced ice maker cycle times, while lowering
More informationFocused Solutions for PARTS WASHING. LOWEST TOTAL COST OF OWNERSHIP Reduced Disposal Fees Reduced Solvent Cost Eliminate monthly rental fees
Focused Solutions for PARTS WASHING LOWEST TOTAL COST OF OWNERSHIP Reduced Disposal Fees Reduced Solvent Cost Eliminate monthly rental fees Waste Stream Minimization Zep s Exclusive multi-stage filtration
More informationOwners Guide ScaleSolver Residential System
Owners Guide ScaleSolver Residential System Models SS-5544S - 1 SS-5544E - 1 1/4 www.lifesourcewater.com CA Lic. #787179 - NV Lic. #059578 Table of Contents Our Promise Lifesource Is A Company You Can
More informationUsed Fluid Handling Portable Used Oil Gravity Drains
Portable Used Oil Gravity Drains Choose the fluid handling equipment that fits your needs. Traditional Drain: the traditional method for handling used fluids allows gravity to drain fluids from vehicle(s)
More informationFleck 5600 Carbon Filter Installation & Start Up Guide
Clean Water Made Easy www.cleanwaterstore.com Fleck 5600 Carbon Filter Installation & Start Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance
More informationTOWN OF SPENCER FIRE and EMERGENCY SERVICES
TOWN OF SPENCER FIRE and EMERGENCY SERVICES Fire Prevention and Protection Regulations For Sub divisions 1. General requirements 2. Hydrants 3. Fire Cisterns Chapter 4. Dry Hydrants 5. Residential Sprinklers
More informationAUTOMATIC IN-FLOOR CLEANING & CIRCULATING SYSTEM
AUTOMATIC IN-FLOOR CLEANING & CIRCULATING SYSTEM INSTALLATION MANUAL MADE IN USA U.S. Patent No.: 4,188,673, 4,212,088, 4,391,005, 4,592,379 5,265,631, 6,301,723, 6,311,728, 6,314,999, 6,360,767 6,367,098,
More informationThe Yellow Can Removes oils & fatty acids
NEW Pricing Effective 2-7-2018 Page 163 NON-CHLORINATED MOLD CLEANER A Powerful Cleaner & Degreaser with No Ozone-Depleting Substances NEW Non Chlorinated PACKAGED IN: Convenient Aerosol Can - OR - Refillable
More informationCistern Connections. Overview: Active rainwater collection systems can be comprised of a few simple and inexpensive components.
Cistern Connections Overview: Youth use games and either a cistern model or actual cistern to identify components, vocabulary, and processes for active rainwater harvesting systems. Active rainwater collection
More informationPRE-INSTALLATION GUIDE
Dry Vacuum System Part Numbers V3, V5, V7, 2V3, 2V3CT, 2V5, 2V5CT, 2V7, 3V5 and 4V5 PRE-INSTALLATION GUIDE All pumps comply with NFPA 99C level 3 requirements. All installations must conform to local codes.
More informationClean Water Made Easy. Fleck 7000 Tannin Filter Installation & Startup Guide. Questions?
Clean Water Made Easy www.cleanwaterstore.com Fleck 7000 Tannin Filter Installation & Startup Guide For Tannin Filters with Vortech Distributor Screen Thank you for purchasing a Clean Water System! With
More informationINSTALLATION & INSTRUCTION MANUAL
INSTALLATION & INSTRUCTION MANUAL CLEARADON SERIES 3311 SHALLOWTRAY AERATION SYSTEM RadonAway 3 Saber Way Ward Hill, MA 01835 radonaway.com TABLE OF CONTENTS SAFETY FIRST!... 1 INSTALLATION PROCEDURE...
More informationINSTALLATION AND OPERATIONS MANUAL
MODEL 6001 REVERSE OSMOSIS High Purity Water Production System THREE STAGE Filtration for the reduction of: Organic Matter Total Dissolved Solids (TDS) Suspended Solids Chemical Contaminants Bad Taste
More informationClean Water Made Easy
Clean Water Made Easy http://www.cleanwaterstore.com Pro-OX 5700-E Iron Filter Installation & Start-Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine
More informationParts Washers, Water Pumps, special applications
Parts Washers, Water Pumps, special applications 147 Parts Washers Storm King Automotive and Industrial Parts Washers Simple Operation Fill the Storm King cleaning basket with parts, close the door, parts
More informationREAD AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS
READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS 1 IMPORTANT SAFETY INSTRUCTIONS Read the instructions The appliance is not to be used by persons (including children) with reduced physical, sensory
More informationUNIVERSITY OF MISSOURI Fire Protection System Design 2016 Q1
GENERAL: 1. All fire protection systems shall be installed in accordance with the International Fire Code and applicable NFPA standards. This guideline provides additional requirements for the design and
More informationOSCAR-LOWeFLOW Treatment System Design Manual January 2018
! OSCAR-LOWeFLOW Treatment System Design Manual January 2018 Manufactured by: Lowridge Onsite Technologies PO Box 1179 Lake Stevens, WA 98258 877 476-8823 info@lowridgetech.com!1 Introduction: This manual
More informationProduct Catalog June 2012
Product Catalog Category Description Page Product Categories 1 Plastic Pipe Cements and Primers Oatey, Hercules and United Elchem solvent cements, primers, cleaners and related products 2 Thread Sealants
More informationWS1 Softener Installation & Start-Up Guide
WS1 Softener Installation & Start-Up Guide Thank you for purchasing a Van Isle Conditioner. With proper installation and a little routine maintenance your system will be providing treated water for many
More informationC. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.
SECTION 22 10 00 PLUMBING PIPING AND PUMPS PART 1 - GENERAL 1.1 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design.
More information1 Introduction Basic Heliocol terminology Designing your system Parts and tools Hydraulics Installation...
INSTALLATION MANUAL SWIMMING POOL SOLAR HEATING SYSTEM Before attempting installation, read these instructions and acquaint yourself with the component names. Great care has been taken to make this an
More informationFOR THE RECORD. You should record the model and serial numbers, which can be found on the back of the unit, for future reference.
FOR THE RECORD You should record the model and serial numbers, which can be found on the back of the unit, for future reference. Warranty: 18 mo. on unit and 1 year on check valve assembly Model: The Ozone
More informationPolyMax H1-10 Dutch Bucket System
112529 PolyMax H1-10 Dutch Bucket System *Actual system may differ. PolyMax Dutch Buckets Versatile PolyMax Dutch Buckets are ideal for both small- and large-scale hydroponic growing. STK# DIMENSIONS 112529
More informationOSCAR-LOWeFLOW Treatment System Design Manual October 2016
!! OSCAR-LOWeFLOW Treatment System Design Manual October 2016 (Patent Number 8,889,007 & Patent Pending) Manufactured by: Lowridge Onsite Technologies PO Box 1179 Lake Stevens, WA 98258 877 476-8823 info@lowridgetech.com!1
More informationSpare Parts Catalogue MF56
Spare Parts Catalogue MF56 1 - UNIT PANELS 2 - REFRIGERANT SYSTEM AIR COOLED 3 - REFRIGERANT SYSTEM WATER COOLED 4 - WATER SYSTEM AND INSULATIONS - UP TO S.N. 23384 5 - WATER SYSTEM AND INSULATIONS - FROM
More informationGreen Water Systems OWNERS MANUAL. Includes: Installation Procedures, Warranties, Service & Operation Guidelines.
Green Water Systems OWNERS MANUAL Includes: Installation Procedures, Warranties, Service & Operation Guidelines. GS Elite GS PRO GS1 1 Cu. Ft. S. C. S. GS1.5 1 Cu. Ft. S. C. S. GS2 2 Cu. Ft. S. C. S. 7000
More informationINSTALLATION MANUAL GEO-BOOST GROUND LOOP HEAT EXCHANGER
INSTALLATION MANUAL GEO-BOOST GROUND LOOP HEAT EXCHANGER Build Equinox support@buildequinox.com (773)-492-1893 Rev 2.0-05/10/2018 Build Equinox 2018 The Geo-Boost system consists of the Geo-Boost heat
More informationDesign of a CO 2 Injection System for Sequestration and Enhanced Oil and Gas Recovery Testing
Design of a CO 2 Injection System for Sequestration and Enhanced Oil and Gas Recovery Testing By: Ray McKaskle Trimeric Corporation Co-Authors: Kevin Fisher Trimeric Corporation Scott Frailey Illinois
More informationWeb:
P.O Box - 95466, United Arab Emirates Tel: +971 4 2637073, Mobile: +971 55 2191246, +971 52 864 1667 Email: info@sancouae.com, Web: It's about Peace of mind and a job done right, First time, Every time
More informationWHITE PAPER The Importance of Rinsing in Metal Finishing Operations
WHITE PAPER The Importance of Rinsing in Metal Finishing Operations By Steve Rudy, CEF & Sales/Technical Representative The focus or driving force of rinsing is to eliminate contaminants from the surface.
More informationROTISSERIE OVEN PROGRAM GUIDE
ROTISSERIE OVEN PROGRAM GUIDE Goslyn, LP 1904 University Business Dr. #310 McKinney TX 75071 Phone: 888-648- 5040 Fax: 214-618- 3765 WWW.GOSLYN.COM DEC 2013 table of contents general overview 3 Installation
More informationJ-PRO-22 Pump Proportional Feed Hydrogen Peroxide Installation & Start-Up Guide
J-PRO-22 Pump Proportional Feed Hydrogen Peroxide Installation & Start-Up Guide Thank you for purchasing a Clean Water System! Please review this start-up guide entirely before beginning to install your
More informationUNIT PANELS 6/25/ :15:30 AM Page 2 of 27
MF56 1 UNIT PANELS 2 REFRIGERANT SYSTEM AIR COOLED 3 REFRIGERANT SYSTEM WATER COOLED 4 WATER SYSTEM AND INSULATIONS - UP TO S.N. 23384 5 WATER SYSTEM AND INSULATIONS - FROM S.N. 23385 TO S.N. 24159 6 WATER
More information