irritec USA irritec USA THE MODULAR SAND MEDIA FILTER TM Water Tool Filters

Size: px
Start display at page:

Download "irritec USA irritec USA THE MODULAR SAND MEDIA FILTER TM Water Tool Filters"

Transcription

1 irritec

2 The Modular Sand Media Filter is an advanced filtration system, designed from the ground up, especially for media filtration, to provide the ultimate Sand Media Filter. Each Modular Filter Tank is capable of flowing between 15 and 25 gallons per minute depending on the mesh of the sand, coarse or fine sand media. Each Modular Sand Media Filter Tank is self contained with a flush valve. The flush valve can be operated manually or automatic. Automatic Flushing is operated by a Two Wire Back Flush Controller (96 station tanks), thereby keeping the number of wires leaving the controller to the entire Modular Filter System to only two wires. Each Modular Sand Media Filter tank is equipped with a Receiver and Solenoid. The Receiver is coded to receive the code from the controller to operate the Back Flush Valve to that particular tank. As more tanks are added to the system, no extra wires are needed to the controller, only continue the two wire cable to the added tanks. In larger systems, when an abundant amount of Modular Sand Media Filter tanks are used, flushing more than one tank at a time is an option. Up to three tanks can be operated from one back flush solenoid. The Solenoids are plumbed individually with ¼ tubing. This design eliminates all the plumbing and long runs as on other sand media filters. It is designed to be neat, clean and efficient. The Back Flush valve can be unassembled in less than one minute for easy and fast servicing. A unique manifold system makes assembly of the Modular Sand Media Filter a snap to install. All connections are union type and can be hand tightened for easy installation and removal. The design of the Modular Filter is simple and efficient. The Foot Print of the Modular Sand Media Filter system is similar to Steel and Stainless Steel tank media filter systems. Existing sand media filter systems are offered in sizes that sometimes do not fit the gallons required for your system. Those are either too big, causing troublesome back flush or too small causing higher pressure losses. With the Modular Sand Media Filter system you can design the system for the exact gallons per minute required of the system design (plus or minus 20 GPM). If you add to your acreage, simply add the required Modular Sand Media Filter tanks needed no mess, and no fuss. The light weight Modular Sand Media Filter is manufactured of Glass Filled Nylon, a proven material for long life. The Easy Assembly Manifold is manufactured of UVR (Ultra Violet Resistant) PVC. Each Modular Sand Media tank will hold only 5 gallons of the required sand mesh size. An easy fill port is provided on the top of the filter for filling the sand media. There is an easy access port on the bottom of the filter for draining and replacing the media. The unique Modular design of the Sand Media Filter makes back flushing very efficient. For example, on a 480 GPM, 2-48 tank system, back flushing of one tank will take over 50% of the water flow. This lowers the pressure on the system causing slow action of the back flush valve. In some cases an expensive pressure sustaining valve must be used. This is not necessary in a multi tank Modular Sand Media Filter system. This wastes water and causes longer flush times to achieve a maximum cleaning of the filter. With the Modular Sand Media Filter, the back flush system will operate only 1 of the 20 tanks (as compared to a 2-48 tank system), only 5% of the system flow. There will be minimum pressure loss, allowing the flush valve to react quickly and efficiently, with a minimum amount back flush water. The net results being less overall back flush water being used. With back flush flows of approximately 25 GPM, a back flush water recovery system can be utilized at a very low cost, as compared to existing systems on the market today. The Under Drain of the Modular Sand Media Filter is designed especially for this filter, covering 90% of the bottom of the filter. The Under drain back flushes vertically on the upside only. No flow is directed in any direction other than straight up, lifting the filter Media evenly, allowing for the most efficient back flush with a minimum amount of flow available to the market today. The Modular Sand Media Filter is designed to be a Sand Media Filter. It is designed to be water saving efficient. It is light weight, easy to install and easy to maintain. The Modular Sand Media Filter system addresses and corrects the majority of the common faults of existing sand media systems on the market today.

3 Light Weight No Rust - Glass Filled Nylon and UVR PVC Construction Modular Design GPM per Tank - Add as Many Tanks as Needed Minimal Back Flush Water - Individual Back Flush Valves Two Wire Back Flush Controller - 96 Station Back Flush Controller Pressure Switch Similar Foot Print As Existing Sand Media Tanks Back Flush Water Recovery System Available No Pressure Sustaining Valves Needed for Back Flush No Forklifts Needed - Easy Installation Only 5 Gallons of Media Per Tank Available with Groove Inlet / Outlet or Union Connections Supplied with Air Release Valves and Pressure Gauges Full Vertical Underdrain

4 Water Tool Back Flush Controller Hardwire or Solar Power Only Two Wires

5 2 Tank Horizontal

6 3 Tank Horizontal

7 4 Tank Horizontal

8 5 Tank Horizontal

9 6 Tank Horizontal

10 Multiple Tanks in Units of 6 or More - Manifolds Available

11 2 Tank Vertical

12 Flush Flush Flush Flush Flow Out Flow In Flush Flush Flush Flush Typical 48 Tank System 720 gpm gpm (15 gpm each) (25 gpm each)

13 irritec Minimum necessary to remove valve for maintenance / /16" 54-10/16" 30-10/16 12" 15-5/ /16" 12" 14-8/16" 8-15/16" 8-15/ /16" 66-5/8 60-5/16" 33-9/16" 41-1/16" 27-4/16"

14 AUTO FLUSH VALVE UNDERDRAIN UNDERDRAIN ITEM #. QTY. PART #. DESCRIPTION 1 1 WT-154 UNDERDRAIN TEE 2 2 WT-155 UNDERDRAIN O-RING # WT-134 TRIPLE OPEN SEGMENT W / NIPPLE 4 16 WT-133 TRIPLE OPEN SEGMENT 5 2 WT-132 TRIPLE CLOSED / OPEN SEGMENT 6 64 WT-131 SMALL OPEN SEGMENT 7 2 WT-130 SMALL CLOSED SEGMENT 8 12 WT-144 SEGMENT NUT WT-135 SEGMENT BOLT # X WT-136 SEGMENT BOLT # X WT-137 SEGMENT BOLT # X AUTO FLUSH VALVE ITEM #. QTY. PART #. DESCRIPTION 1 1 WT-113 BACK FLUSH LOWER BODY SS SCREWS 3 1 WT-115 #202 - BACK FLUSH O-RING 4 1 WT-116 BACK FLUSH SEAT 5 1 WT-111 1/4 SS ROD 6 1 WT-117 BACK FLUSH SPRING BACK FLUSH DIAPHRAGM 8 1 WT-120 DIAPHRAGM SUPPORT 9 2 WT-145 1/4-28 SS NYLON NUT /4-28 SS NUT 11 1 WT-114 BACK FLUSH UPPER BODY 12 6 WT-146 BACK FLUSH BOLT 13 1 WT /2 UVR SCH 80 TEE 14 1 WT-112 BACK FLUSH ADAPTER 15 1 WT /2 X 2 ADAPTER 17 1 WT /2 UNION NUT 18 1 WT-109 DIAPHRAGM SEAT 19 1 WT-108 SEAT RETAINER BRASS INSERT 21 1 WT-107 VALVE UPPER BODY 22 1 WT-106 VALVE LOWER BODY 23 2 WT /2 UNION MALE THREAD 24 1 WT-159 VALVE UPPER BODY O-RING #227

15 Product List Part Number Description Inlet Outlet Back Flush Back Flush Flow GPM Flow L/M L WT-2HGA 2 Tank Horizontal Groove Groove Union Automatic WT-2HGM 2 Tank Horizontal Groove Groove Union Manual WT-2HUA 2 Tank Horizontal Union Union Union Automatic WT-2HUM 2 Tank Horizontal Union Union Union Manual WT-2VUA 2 Tank Vertical Union Union Union Automatic WT-2VUM 2 Tank Vertical Union Union Union Manual WT-3HGA 3 Tank Horizontal Groove Groove Union Automatic WT-3HGM 3 Tank Horizontal Groove Groove Union Manual WT-3HUA 3 Tank Horizontal Union Union Union Automatic WT-3HUM 3 Tank Horizontal Union Union Union Manual WT-4HGA 4 Tank Horizontal Groove Groove Union Automatic WT-4HGM 4 Tank Horizontal Groove Groove Union Manual WT-4HUA 4 Tank Horizontal Union Union Union Automatic WT-4HUM 4 Tank Horizontal Union Union Union Manual WT-5HGA 5 Tank Horizontal Groove Groove Union Automatic WT-5HGM 5 Tank Horizontal Groove Groove Union Manual WT-5HUA 5 Tank Horizontal Union Union Union Automatic WT-5HUM 5 Tank Horizontal Union Union Union Manual WT-6HGA 6 Tank Horizontal Groove Groove Union Automatic WT-6HGM 6 Tank Horizontal Groove Groove Union Manual WT-6HUA 6 Tank Horizontal Union Union Union Automatic WT-6HUM 6 Tank Horizontal Union Union Union Manual

16 irritec Distributed by: irritec 4450 N. Brawley Ave. SUITE 126 Fresno, CA Toll Free (877) Tel (559) Fax (559)

OSCAR-LOWeFLOW Treatment System Design Manual October 2016

OSCAR-LOWeFLOW Treatment System Design Manual October 2016 !! OSCAR-LOWeFLOW Treatment System Design Manual October 2016 (Patent Number 8,889,007 & Patent Pending) Manufactured by: Lowridge Onsite Technologies PO Box 1179 Lake Stevens, WA 98258 877 476-8823 info@lowridgetech.com!1

More information

215 Gallon Waste Oil Tank With Bypass Regulator Installation Instructions

215 Gallon Waste Oil Tank With Bypass Regulator Installation Instructions 215 Gallon Waste Oil Tank With Bypass Regulator Installation Instructions Lanair Products LLC 4109 Capital Circle Janesville, Wisconsin 53546 1-888-370-6531 www.lanair.com BEFORE YOU BEGIN INSTALLATION...

More information

MODEL CMA-180UC PARTS MANUAL Rev 1.16

MODEL CMA-180UC PARTS MANUAL Rev 1.16 MODEL CMA-180UC PARTS MANUAL Rev 1.16 CMA DISHMACHINES 12700 KNOTT STREET GARDEN GROVE, CALIFORNIA 92841 800-854-6417 FAX 714-895-2141 wwwcmadishmachines.com TABLE OF CONTENTS MODEL CMA-180UC 1. PARTS

More information

WM-450-PT WM-900-PT Commercial Wall Mounted Reverse Osmosis

WM-450-PT WM-900-PT Commercial Wall Mounted Reverse Osmosis WM-450-PT WM-900-PT Commercial Wall Mounted Reverse Osmosis Installation And Service Manual Watts Pure Water 1725 W. Williams Dr. C-20., Phoenix, Arizona 85027 Phone: 888-774-7405 Fax: 602-588-0356 www.wattspurewater.com

More information

model NO. LSS GALLON SKID MOUNTED HIGH PRESSURE SPRAYER ASSEMBLY / OPERATION INSTRUCTIONS / PARTS

model NO. LSS GALLON SKID MOUNTED HIGH PRESSURE SPRAYER ASSEMBLY / OPERATION INSTRUCTIONS / PARTS 000 model NO. LSS- 00 GALLON SKID MOUNTED HIGH PRESSURE SPRAYER ASSEMBLY / OPERATION INSTRUCTIONS / PARTS Part number and descriptions can be obtained from the illustrated parts list section of this manual.

More information

OSCAR-LOWeFLOW Treatment System Design Manual January 2018

OSCAR-LOWeFLOW Treatment System Design Manual January 2018 ! OSCAR-LOWeFLOW Treatment System Design Manual January 2018 Manufactured by: Lowridge Onsite Technologies PO Box 1179 Lake Stevens, WA 98258 877 476-8823 info@lowridgetech.com!1 Introduction: This manual

More information

MODELS CMA-180 VL/180 VLTall PARTS MANUAL Rev 2.02A

MODELS CMA-180 VL/180 VLTall PARTS MANUAL Rev 2.02A MODELS CMA-180 VL/180 VLTall PARTS MANUAL Rev 2.02A C M A D I S H M A C H I N E S 1 2 7 0 0 K N O T T A V E N U E GARDEN GROVE, CALIFORNIA 92841 800-8 5 4-6 4 1 7 FAX 714-895-2141 www.cmadishmachines.com

More information

REPLACEMENT PARTS MANUAL FOR MODEL: PWS 45-75, AED-2 & APK-4 SERIES

REPLACEMENT PARTS MANUAL FOR MODEL: PWS 45-75, AED-2 & APK-4 SERIES PREC SION Water Systems REPLACEMENT PARTS MANUAL FOR MODEL: PWS 45-75, AED-2 & APK-4 SERIES 0004 0002 0001 PRECISION WATER SYSTEMS WATER DISTILLER MANUFACTURED BY: PRECISION DESIGN & MANUFACTURING INC.

More information

MODEL CMA-180UC PARTS MANUAL Rev 1.18

MODEL CMA-180UC PARTS MANUAL Rev 1.18 MODEL CMA-180UC PARTS MANUAL Rev 1.18 CMA DISHMACHINES 12700 KNOTT AVENUE GARDEN GROVE, CALIFORNIA 92841 800-854-6417 FAX 714-895-2141 wwwcmadishmachines.com TABLE OF CONTENTS MODEL CMA-180UC 1. PARTS

More information

Installation Instructions

Installation Instructions Installation Instructions 6 KW and 11.5KW Basic Circulation Water Heater and Pump Application: The Basic Circulation Water Heater has been in use for nearly 50 years, and it is the most prevalent model

More information

MODELS CMA-180 VL/180 VLTall PARTS MANUAL Rev 2.02B

MODELS CMA-180 VL/180 VLTall PARTS MANUAL Rev 2.02B MODELS CMA-180 VL/180 VLTall PARTS MANUAL Rev 2.02B C M A D I S H M A C H I N E S 1 2 7 0 0 K N O T T A V E N U E GARDEN GROVE, CALIFORNIA 92841 800-8 5 4-6 4 1 7 FAX 714-895-2141 www.cmadishmachines.com

More information

Aer-Max Installation Instructions

Aer-Max Installation Instructions Aer-Max Installation Instructions Congratulations on selecting this quality Aer-Max system. Important: Please read all instructions before assembling and installing the Aer-Max system. Consult local plumbing

More information

J120 STEAM BOOSTER INSTALLATION, OPERATION, AND SERVICE MANUAL J120 STEAM BOOSTER. J120 Steam Booster Manual D

J120 STEAM BOOSTER INSTALLATION, OPERATION, AND SERVICE MANUAL J120 STEAM BOOSTER. J120 Steam Booster Manual D INSTALLATION, OPERATION, AND SERVICE MANUAL J120 STEAM BOOSTER J120 STEAM BOOSTER J120 Steam Booster Manual REVISION HISTORY Revision Letter Revision Date Made by Applicable ECNs Details A 10-27-04 CBW

More information

Owner's Manual. (200 Gallon Lawn Service Skid Sprayer) Technical Specifications. Operation. General Information. Warranty/Parts/Service

Owner's Manual. (200 Gallon Lawn Service Skid Sprayer) Technical Specifications. Operation. General Information. Warranty/Parts/Service Owner's Manual (00 Gallon Lawn Service Skid Sprayer) Technical Specifications. Horsepower Recoil Start Engine Roller Cast Iron Pump 0 Gallons Per Minute at 0 PSI Pressure Gauge-Adjustable Pressure Range

More information

OSCAR-LOWeFLOW Treatment System Design Manual August 2017

OSCAR-LOWeFLOW Treatment System Design Manual August 2017 ! OSCAR-LOWeFLOW Treatment System Design Manual August 2017 Manufactured by: Lowridge Onsite Technologies PO Box 1179 Lake Stevens, WA 98258 877 476-8823 info@lowridgetech.com!1 Introduction: The OSCAR

More information

Clean Water Made Easy. CWS Time Clock Softener Installation & Start Up Guide. Questions?

Clean Water Made Easy. CWS Time Clock Softener Installation & Start Up Guide. Questions? Clean Water Made Easy www.cleanwaterstore.com CWS Time Clock Softener Installation & Start Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance

More information

MODEL CMA-180UC SERVICE & PARTS MANUAL Rev 1.10

MODEL CMA-180UC SERVICE & PARTS MANUAL Rev 1.10 MODEL CMA-180UC SERVICE & PARTS MANUAL Rev 1.10 CMA DISHMACHINES 12700 KNOTT AVENUE GARDEN GROVE, CALIFORNIA 92841 800-854-6417 FAX 714-895-2141 www.cmadishmachines.com 0203 TABLE OF CONTENTS MODEL CMA-180UC

More information

REPLACEMENT PARTS MANUAL

REPLACEMENT PARTS MANUAL PREC SION Water Systems REPLACEMENT PARTS MANUAL FOR MODEL: PWS 12-20(120VAC), PWS 12-20(240VAC), AED-1(120VAC), AED-1(240VAC), APK-1(120VAC) & APK-1(240VAC) PART # 510001 510003 500006 500015 500007 500016

More information

WARNING DESCRIPTION PART NUMBER QTY PLUMBING, DYNATEMP DRAIN QUENCH BRACKET, THERMOSTAT DRAIN QUENCH

WARNING DESCRIPTION PART NUMBER QTY PLUMBING, DYNATEMP DRAIN QUENCH BRACKET, THERMOSTAT DRAIN QUENCH ! WARNING WARNING: This kit should be installed only by qualified service personnel to reduce the risk of electric shock, serious injury, or fire. A plumbing permit and the services of a licensed plumber

More information

CMA Dishmachines Knott Avenue Garden Grove, CA Undercounter High Temperature Dishwasher. Service Replacement Parts.

CMA Dishmachines Knott Avenue Garden Grove, CA Undercounter High Temperature Dishwasher. Service Replacement Parts. CMA Dishmachines 1700 Knott Avenue Garden Grove, CA 981 Toll Free: 1- (800) 8-617 Fax: 1- (71) 89-11 Service Replacement Parts Undercounter High Temperature Dishwasher Model: UC6e M Machine Serial No.

More information

REPLACEMENT PARTS MANUAL

REPLACEMENT PARTS MANUAL PREC SION Water Systems REPLACEMENT PARTS MANUAL FOR MODEL: PWS 8-8(120VAC), PWS 8-8(240VAC), AED-1(120VAC), AED-1(240VAC), APK-1(120VAC) & APK-1(240VAC) PART # 500003 500014 500006 500015 500007 500016

More information

JOHN DEERE GATOR HPX/XUV 2 PASSENGER HEATER INSTALLATION INSTRUCTIONS (p/n: 9PH20S30)

JOHN DEERE GATOR HPX/XUV 2 PASSENGER HEATER INSTALLATION INSTRUCTIONS (p/n: 9PH20S30) P. 1 of 12 JOHN DEERE GATOR HPX/XUV 2 PASSENGER HEATER INSTALLATION INSTRUCTIONS (p/n: 9PH20S30) Item: Qty: Description: 1 2 1 x 1 x 5/8 Tee Fitting 2 2 Plastic Snap-in Hose Grommet 3 4 1-1/2" Hose Clamps

More information

J-PRO V 230V Dual Voltage Hydrogen Peroxide Pump Installation & Start-Up Guide

J-PRO V 230V Dual Voltage Hydrogen Peroxide Pump Installation & Start-Up Guide J-PRO-22 110V 230V Dual Voltage Hydrogen Peroxide Pump Installation & Start-Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance, your system

More information

General System Layout Sketch

General System Layout Sketch General System Layout Sketch SW-38 Solar Panel(s) Hot Water Cold Water PV panel Glycol RV Water Heater WITH built in Heat Exchanger Water Ports ` Glycol Fill Valve 1 Pump Solar Powered Expansion Tank Glycol

More information

Semi-Automatic Suction Screen Filters 3"-4 Angle. Service & Maintenance Manual

Semi-Automatic Suction Screen Filters 3-4 Angle. Service & Maintenance Manual Semi-Automatic Suction Screen Filters 3"-4 Angle Service & Maintenance Manual Safety Instructions Prior to installation or handling of the filter, read the Installation and Operation instructions carefully.

More information

High Capacity Instantaneous Steam Fired Water Heater

High Capacity Instantaneous Steam Fired Water Heater MODEL F High Capacity Instantaneous Steam Fired Water Heater Features Compact High Capacity Design Packaged System Water heater is factory assembled on an all welded steel mounting frame to save time and

More information

F-P, F-L, FT-P AND FT-L SERIES 2/3 JACKETED DIRECT STEAM TILTING & STATIONARY KETTLES PARTS AND SERVICE MANUAL

F-P, F-L, FT-P AND FT-L SERIES 2/3 JACKETED DIRECT STEAM TILTING & STATIONARY KETTLES PARTS AND SERVICE MANUAL F-P, F-L, FT-P AND FT-L SERIES 2/3 JACKETED DIRECT STEAM TILTING & STATIONARY KETTLES PARTS AND SERVICE MANUAL EFFECTIVE NOVEMBER 2, 2015 Superseding All Previous Parts Lists. The Company reserves the

More information

WARNING. Failure to install this kit within the guidelines might adversely affect safety, performance, component life and warranty coverage.

WARNING. Failure to install this kit within the guidelines might adversely affect safety, performance, component life and warranty coverage. ! WARNING WARNING: This kit should be installed only by qualified service personnel to reduce the risk of electric shock, serious injury, or fire. A plumbing permit and the services of a licensed plumber

More information

J-PRO V 230V Dual Voltage Chlorinator Installation & Start-Up Guide

J-PRO V 230V Dual Voltage Chlorinator Installation & Start-Up Guide J-PRO-22 110V 230V Dual Voltage Chlorinator Installation & Start-Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance, your system will be providing

More information

FILTRATION SYSTEM MODEL: FILTER - 5 MULTI-SHIFTER, INC. P.O. BOX CHARLOTTE, N.C TEL#: FAX#:

FILTRATION SYSTEM MODEL: FILTER - 5 MULTI-SHIFTER, INC. P.O. BOX CHARLOTTE, N.C TEL#: FAX#: FILTRATION SYSTEM MODEL: FILTER - 5 MULTI-SHIFTER, INC. P.O. BOX 411047 CHARLOTTE, N.C. 28241-1047 TEL#: 1-704-588-9611 FAX#: 1-704-588-4730 CONTENTS 1. System Overview 2. Air and Electrical Requirements

More information

Care and Use Manual Tank Series Appliances

Care and Use Manual Tank Series Appliances Care and Use Manual Tank Series Appliances 4.4-1 Information Provided for the Proper Set-Up, Installation and Start-Up of the following Appliances: EWS Series of Whole Home Filtration and Physical Conditioning:

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS VARIABLE SPEED BOOSTER PUMP IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS IMPORTANT SAFETY INFORMATION WARNING: RISK OF ELECTRICAL SHOCK

More information

Paragon PW750F two stage Drinking Water Filtration System Installation & Operation Manual

Paragon PW750F two stage Drinking Water Filtration System Installation & Operation Manual Paragon PW750F two stage Drinking Water Filtration System Installation & Operation Manual Marketed & Distributed in Singapore by: Quantum Impact Pte Ltd (UEN 201014570H) Add:16 Raffles Quay, #41-07, Hong

More information

REPLACEMENT PARTS MANUAL

REPLACEMENT PARTS MANUAL PREC SION Water Systems REPLACEMENT PARTS MANUAL FOR MODEL: PWS 8-5(120VAC), PWS 8-5(240VAC), AED-1(120VAC), AED-1(240VAC), APK-2(120VAC) & APK-2(240VAC) PART # 500002 500013 500006 500015 500008 500017

More information

OPERATING AND MAINTENANCE MANUAL FOR INSTANTANEOUS STEAM FIRED WATER HEATER ELECTRIC HEATER COMPANY BASE MODEL F

OPERATING AND MAINTENANCE MANUAL FOR INSTANTANEOUS STEAM FIRED WATER HEATER ELECTRIC HEATER COMPANY BASE MODEL F OPERATING AND MAINTENANCE MANUAL FOR INSTANTANEOUS STEAM FIRED WATER HEATER ELECTRIC HEATER COMPANY BASE MODEL F Edition 2013 HUBBELL ELECTRIC HEATER COMPANY P.O. BOX 288 STRATFORD, CT 06615 PHONE: (203)

More information

Polymer Dilution Blend and Feed Specifications For General Use

Polymer Dilution Blend and Feed Specifications For General Use Polymer Dilution Blend and Feed Specifications For General Use Electronic Diaphragm Metering Pump 1.0 GENERAL The contractor shall furnish and install polymer dilution blending and feeding units together

More information

Owner s Manual GLC MANUAL INSTALLATION SERVICE PARTS REV.1.00

Owner s Manual GLC MANUAL INSTALLATION SERVICE PARTS REV.1.00 Owner s Manual GLC MANUAL INSTALLATION SERVICE PARTS REV.1.00 C M A D I S H M A C H I N E S 1 2 7 0 0 K N O T T S T R E E T GARDEN GROVE, CALIFORNIA 92841 800-8 5 4-6 4 1 7 F A X 7 1 4-8 9 5-2141 www.cmadishmachines.com

More information

Hanging Basket Watering Systems

Hanging Basket Watering Systems Hanging Basket Watering Systems A Labor Saving Drip System for Watering Hanging Baskets Lower Input Costs Increases Profitability Hanging Basket growers needing to reduce or eliminate their hand watering

More information

Owner s Manual GW-100 MANUAL INSTALLATION SERVICE PARTS REV.1.00

Owner s Manual GW-100 MANUAL INSTALLATION SERVICE PARTS REV.1.00 Owner s Manual GW-100 MANUAL INSTALLATION SERVICE PARTS REV.1.00 C M A D I S H M A C H I N E S 1 2 7 0 0 K N O T T S T R E E T GARDEN GROVE, CALIFORNIA 92841 800-8 5 4-6 4 1 7 F A X 7 1 4-8 9 5-2141 www.cmadishmachines.com

More information

Model AV Alarm Valve With and Without Model RC-1 Retard Chamber European Conformity Valve Trim General Description

Model AV Alarm Valve With and Without Model RC-1 Retard Chamber European Conformity Valve Trim General Description Worldwide Contacts www.tyco-fire.com Model AV--00 Alarm Valve With and Without Model RC- Retard Chamber European Conformity Valve Trim General Description The TYCO Model AV--00 Alarm Valves DN, DN0, DN0,

More information

A B A B4

A B A B4 TM TM SERVICE INSTRUCTIONS Thermo-Aire Heater Kits and Air-Heater Assemblies 383808-A4 383808-B4 383880-A4 383880-B4 DESCRIPTION The Thermo-Aire Heater is used in situations where oils of heavier viscosity

More information

NOTE: Parts are no longer available for this tool. The manual will continue on the next page.

NOTE: Parts are no longer available for this tool. The manual will continue on the next page. NOTE: Parts are no longer available for this tool. The manual will continue on the next page. ------------------------------------------------- CATALOG NO. 7628 Form No. Z21 0 Date 1-93 High Pressure Power

More information

Safety. Rinse Kit for Multi-Pro 1200 and 1250 Turf Sprayers Model No Safety and Instructional Decals. Installation Instructions

Safety. Rinse Kit for Multi-Pro 1200 and 1250 Turf Sprayers Model No Safety and Instructional Decals. Installation Instructions Rinse Kit for Multi-Pro 1200 and 1250 Turf Sprayers Model No. 106-4842 Form No. 3353-529 Rev B Installation Instructions Note: Determine the left and right sides of the machine from the normal operating

More information

Owner s Manual. Keep with machine for reference PKC24 INSTALLATION & OPERATION REV Perlick Corporation 8300 W Good Hope Rd Milwaukee, WI 53223

Owner s Manual. Keep with machine for reference PKC24 INSTALLATION & OPERATION REV Perlick Corporation 8300 W Good Hope Rd Milwaukee, WI 53223 Owner s Manual Keep with machine for reference PKC24 INSTALLATION & OPERATION REV.11.09 Perlick Corporation 8300 W Good Hope Rd Milwaukee, WI 53223 800-558- 5592 FAX 414-353- 7069 perlick.com TABLE OF

More information

Model 10AB/APRB Automatic Dishwasher

Model 10AB/APRB Automatic Dishwasher Model 10AB/APRB Automatic Dishwasher Rinse and Wash Head Assemblies ITEM 1 0126800 End Plug 2 0125000 Rinse Arm Body (only) 3 0126000 Nylatron Washer (2 places) 4 0125500 Hex Nut 5 0126500 Snap Ring 6

More information

GLC/GW-100 MANUAL INSTALLATION SERVICE PARTS REV.1.01

GLC/GW-100 MANUAL INSTALLATION SERVICE PARTS REV.1.01 Owner s Manual Keep with machine for reference GLC/GW-100 MANUAL INSTALLATION SERVICE PARTS REV.1.01 CMA DISHMACHINES 12700 KNOTT STREET GARDEN GROVE, CALIFORNIA 92841 800-854- 6417 FAX 714-895- 2141 www.cmadishmachines.com

More information

General System Layout Sketch

General System Layout Sketch General System Layout Sketch EZ-37 Solar Panels PV panel Glycol Fill Valve Expansion Tank ` 1 Introduction This document describes how to install a Heliatos GH type solar water heating system. These systems

More information

DAD-500 (130026) DESICCANT AIR DRYING SYSTEM

DAD-500 (130026) DESICCANT AIR DRYING SYSTEM SERVICE BULLETIN SB---O Replaces SB---N DAD-00 (00) DESICCANT AIR DRYING SYSTEM Air In 0 The CFM DAD-00 Desiccant Air Drying System is designed to be a point of use system. It is capable of removing dirt,

More information

541D19 SERIES. Technical Manual. A Division of Aquion Partners L.P.

541D19 SERIES. Technical Manual. A Division of Aquion Partners L.P. 541D19 SERIES Technical Manual A Division of Aquion Partners L.P. Table of Contents Introduction... Page 1 Technical Specifications... Page 2 Flow Diagrams... Page 3 Injector & Flow Control Selection Injector...

More information

Kinetico 2060f OD Sulfur Guard Installation Instructions

Kinetico 2060f OD Sulfur Guard Installation Instructions SAFETY GUIDELINES Read all steps, guides, and rules carefully before installing and using the Kinetico 2060f OD Sulfur Guard. Check your local building and sanitation codes for installation compliance.

More information

Parts Manual Vermeer/McLaughlin V500LTHD Vacuum Machine Part #E (SERIAL # 5DHDLT _5DHDLT )

Parts Manual Vermeer/McLaughlin V500LTHD Vacuum Machine Part #E (SERIAL # 5DHDLT _5DHDLT ) 006 Perimeter Road. Greenville, SC 9605 Toll Free: 800/5-90 - Phone: 86/77-5870 Fax: 86/5-9661 - Website address: www.mightymole.com Email address: mmole@mightymole.com Parts Manual Vermeer/McLaughlin

More information

SEA FROST BAITFREEZER 110-VOLT AIR-WATER Twin Valve

SEA FROST BAITFREEZER 110-VOLT AIR-WATER Twin Valve 372 ROUTE 4 BARRINGTON, NH 03825 USA TEL (603) 868-5720 FAX (603) 868-1040 1-800-435-6708 E-Mail:sales@seafrost.com www.seafrost.com SEA FROST BAITFREEZER 110-VOLT AIR-WATER Twin Valve Operation and Installation

More information

Instructions CH Chrome SS Stainless Steel Certifications. Single Handle, Pull-Down, Kitchen Faucet. Tools Required.

Instructions CH Chrome SS Stainless Steel Certifications. Single Handle, Pull-Down, Kitchen Faucet. Tools Required. Instructions *Image may vary slightly from actual product Tools Required Adjustable Wrench Groove Joint Pliers Pipe Wrench Phillips Screwdriver Pipe Tape or pipe thread compound Safety Tips If you solder

More information

OSCAR-LOWeFLOW Treatment Unit Installation Manual. January Residential

OSCAR-LOWeFLOW Treatment Unit Installation Manual. January Residential OSCAR-LOWeFLOW Treatment Unit Installation Manual January 2016 Residential US Patent # 8,889,007 Manufactured by: Lowridge Onsite Technologies, LLC PO Box 1179 Lake Stevens, WA 98258 877-476-8823 info@lowridgetech.com

More information

SERIES WATERERS INSTALLATION INSTRUCTIONS

SERIES WATERERS INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Read and study entire booklet carefully before beginning installation. Use only Nelson accessories and replacement parts. Save this booklet. Call if you have questions. SERIES

More information

Parts & Material Included

Parts & Material Included O² Hydro Well System Installation, Use & Care Guide Parts & Material Included 1. Funnel 11. Drain Line 21. Air Head 2. Media Tank Distributer Tube 12. Air Release 22. Drain Fitting 3. Air Tank Distributer

More information

Series 20 Dual Check Backflow Preventers

Series 20 Dual Check Backflow Preventers Series 20 Dual Check Backflow Preventers Excellence Matters Specify It! A Division of Watts Regulator Company 427 North Market Blvd Suite #9 Sacramento, CA 9584 Phone: 96-928-02 Fax: 96-928-9 www.amesfirewater.com

More information

4-1 1 / 2 " Tees / 2 " hole saw w/ 1/4" drill bit / 2 " Male slip plugs

4-1 1 / 2  Tees / 2  hole saw w/ 1/4 drill bit / 2  Male slip plugs Section 1: Parts List 1-50 Flex PVC pipe 2-1 1 / 2 " Ball Valves 4-1/2" 90 degree elbows 4 - Lengths of 1/2" PVC 4 - Jet bodies 4 - Jet nozzles 4 - Female slip/female slip unions 2 - Female slip/fpt union

More information

IMAGE V. Parts and Service Manual

IMAGE V. Parts and Service Manual IMAGE 0V Section II Parts and Service Manual (88B) CLARKE TECHNOLOGY Image Operator's Manual Page AUTHORIZED PERSONNEL MAINTENANCE To Access Pump Motor. Remove brush housing from machine. See "Brush Motor

More information

KPS-DS, KLS-DS, KPT-DS AND KLT-DS SERIES 2/3 JACKETED DIRECT STEAM TILTING & STATIONARY KETTLES PARTS AND SERVICE MANUAL

KPS-DS, KLS-DS, KPT-DS AND KLT-DS SERIES 2/3 JACKETED DIRECT STEAM TILTING & STATIONARY KETTLES PARTS AND SERVICE MANUAL KPS-DS, KLS-DS, KPT-DS AND KLT-DS SERIES 2/3 JACKETED DIRECT STEAM TILTING & STATIONARY KETTLES PARTS AND SERVICE MANUAL EFFECTIVE NOVEMBER 2, 2015 Superseding All Previous Parts Lists. The Company reserves

More information

(Toll Free); 7am-7pm Pacific Time, Monday-Saturday. Assembly instructions for: DUSTIN S FACE TO FACE GLIDERS WITH XW ROOF

(Toll Free); 7am-7pm Pacific Time, Monday-Saturday. Assembly instructions for: DUSTIN S FACE TO FACE GLIDERS WITH XW ROOF 866.332.2403 (Toll Free); 7am-7pm Pacific Time, Monday-Saturday Assembly instructions for: DUSTIN S FACE TO FACE GLIDERS WITH XW ROOF FRAME QUANTITY DRAWING 2 Structure Supports 2 Supports 1 Base support

More information

Figure 1 - Steam Generator. Electrical Installation Instructions. 01/09 Pub. No. 200-A - 1 -

Figure 1 - Steam Generator. Electrical Installation Instructions. 01/09 Pub. No. 200-A - 1 - Electrical Installation Instructions C US Steambath Generators The Steamist TSG Generator operates with a TSC control mounted inside and optional TSR remote control located outside the steamroom. It s

More information

Whirlpool Spa PARTS CATALOG MODEL #F ISSUE DATE: 6/95 CATALOG #G766000

Whirlpool Spa PARTS CATALOG MODEL #F ISSUE DATE: 6/95 CATALOG #G766000 The LEXUS TM L.C. Whirlpool Spa PARTS CATALOG MODEL #F9000 ISSUE DATE: /9 CATALOG #G000 CONTENTS Lexus L. C. Reference Discharge Plumbing Discharge Plumbing (Continued) Suction Plumbing Air Line Piping

More information

PARTS STOCKED REPLACEMENT FAUCET BIBB SCREWS... SCREW ASSORTMENT MISC. 3 /8" BIBB LOC SCREW 1 /2" BIBB SCREW 1 /2" BIBB LOC SCREW 3 /8" BIBB SCREW

PARTS STOCKED REPLACEMENT FAUCET BIBB SCREWS... SCREW ASSORTMENT MISC. 3 /8 BIBB LOC SCREW 1 /2 BIBB SCREW 1 /2 BIBB LOC SCREW 3 /8 BIBB SCREW January 1, 2001 STOCKED REPLACEMENT FAUCET BIBB SCREWS... Parts-5L 3 /8" BIBB SCREW 6-32 GAUGE CHROME 35138- No. 1 3 /8" BIBB SCREW 10-24 GAUGE CHROME 35153- No. 16 3 /8" BIBB SCREW 8-32 GAUGE CHROME 35141-

More information

Instruction Sheet AquaMotionHot One AMH1K-1 Point of Use Hot Water Recirculation System

Instruction Sheet AquaMotionHot One AMH1K-1 Point of Use Hot Water Recirculation System Effective: 5/13/15 Supersedes: New IS-AM09-601 Instruction Sheet Point of Use Hot Water Recirculation System THANK YOU for purchasing a new Aquamotion Hot System! For optimum reliability and performance

More information

Instructions. 110-KVD-CYSCH-AD-Z Chrome 110-KVD-CYSSS-AD-Z Stainless Steel Certifications. Single Handle, Pull-Down, Kitchen Faucet

Instructions. 110-KVD-CYSCH-AD-Z Chrome 110-KVD-CYSSS-AD-Z Stainless Steel Certifications. Single Handle, Pull-Down, Kitchen Faucet Instructions *Image may vary slightly from actual product Tools Required Adjustable Wrench Groove Joint Pliers Pipe Wrench Phillips Screwdriver Pipe Tape or pipe thread compound Safety Tips If you solder

More information

Installation Instructions for. OmniFount

Installation Instructions for. OmniFount Installation Instructions for OmniFount Congratulations, you have just purchased the finest watering fountain on the market. This unit is built to give you excellent service when properly installed and

More information

WS1 Softener Installation & Start-Up Guide

WS1 Softener Installation & Start-Up Guide WS1 Softener Installation & Start-Up Guide Thank you for purchasing a Van Isle Conditioner. With proper installation and a little routine maintenance your system will be providing treated water for many

More information

Lavatory Faucet INSTALLATION INSTRUCTIONS P24490-CR, P24490-LV, P24491-CR, P24491-LV, P24492-CR, P24492-LV, P24700, P24705, P24706, P24736, P24800

Lavatory Faucet INSTALLATION INSTRUCTIONS P24490-CR, P24490-LV, P24491-CR, P24491-LV, P24492-CR, P24492-LV, P24700, P24705, P24706, P24736, P24800 P24490-CR, P24490-LV, P24491-CR, P24491-LV, P24492-CR, P24492-LV, P24700, P24705, P24706, P24736, P24800 2018 1 of 7 KALLISTA THANK YOU FOR CHOOSING KALLISTA We appreciate your commitment to KALLISTA quality

More information

CALEFFI. SEP4 combination hydraulic, air, dirt and magnetic separator series 01249/13.1 NA. Replaces 01249/13 NA. Function.

CALEFFI. SEP4 combination hydraulic, air, dirt and magnetic separator series 01249/13.1 NA. Replaces 01249/13 NA. Function. SEP4 combination hydraulic, air, dirt and magnetic separator 5495 series CCREDITED ISO 9001 FM 21654 ISO 9001 No. 0003 CLEFFI 01249/13.1 N Replaces 01249/13 N Product range Function combination hydraulic,

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS ,t_2007 Lennox Industries Inc. Dallas, Texas, USA INSTALLATION INSTRUCTIONS CH33 Series Units EVAPORATOR 505,264M (65484504) 10/07 Supersedes 09/06 COILS n _putech blications ical Litho U.S.A. RETAIN THESE

More information

INDUSTRIAL CONDENSATE POLISHERS. LWTCP Series

INDUSTRIAL CONDENSATE POLISHERS. LWTCP Series INDUSTRIAL CONDENSATE POLISHERS 150,000 TO 3,000,000 GRAINS CAPACITY (Sodium Cycle) Optimum Efficiency And Proven Reliability 1 P a g e Condensate Polishers are important in systems treating condensed

More information

E. F. G. H. I. J. K. L. M. Alternate Energy Technologies, LLC. P F

E. F. G. H. I. J. K. L. M. Alternate Energy Technologies, LLC. P F UDX No Sweat Kit instuctions The No Sweat Kit is intended to be used in conjunction with the AET s DB-10-10XC and DB-15-15XC on a 120 or 80 gallon OST (American Water Heater) top or side connect tank.

More information

Standard Tank One (Approximately 1500 gallons)

Standard Tank One (Approximately 1500 gallons) Standard Tank One (Approximately 1500 gallons) 11' 0" 6" PVC tee Cap / Clean out From Bay Drain See Note 2 1-1/4 Ozone return Line, terminate with a tee 6 Tee 6 PVC To Tank Two See Note 3 6 Transfer 5'

More information

ROTARY VANE VACUUM PUMPS Exploded View DuraVane Rotary Vane Pumps Oil-Lubricated RVL301HH

ROTARY VANE VACUUM PUMPS Exploded View DuraVane Rotary Vane Pumps Oil-Lubricated RVL301HH Exploded View Pumps RVL0HH 95 SOUTH WOODLAND AVENUE, MICHIGAN CITY, IN 0-57 Please visit our website at Page Number Reference TOLL-FREE: 888-95-5 TEL.: 9-8-0 FAX: 9-8-0 www.dekkervacuum.com DWG //05 RVL0HH

More information

Installation Instructions PRO SERIES

Installation Instructions PRO SERIES Installation Instructions PRO SERIES If you are a plumber installing this unit, please leave this owners manual & warranty card with the owner when you finish the installation. Thank You! DO NOT USE THIS

More information

INSTALLATION OF DURAVENT POLYPRO SINGLE WALL POLYPROPYLENE VENTING SYSTEMS

INSTALLATION OF DURAVENT POLYPRO SINGLE WALL POLYPROPYLENE VENTING SYSTEMS SUPPLEMENT VENTING INSTRUCTIONS FOR INSTALLATION AND OPERATION INSTRUCTION MANUALS FOR THE FOLLOWING PRODUCT TYPES: HIGH EFFICIENCY CONDENSING COMMERCIAL, COMMERCIAL POWER DIRECT VENT, LIGHT DUTY COMMERCIAL

More information

DIRTMAG dirt separator with magnet, adjustable for vertical or horizontal pipe

DIRTMAG dirt separator with magnet, adjustable for vertical or horizontal pipe DIRTMAG dirt separator with magnet, adjustable for vertical or horizontal pipe Copyright 206 Caleffi NA0322.02 www.caleffi.com NA5453 Series Installation, commissioning and servicing instructions Function

More information

Technical Specifications & Pricing

Technical Specifications & Pricing Nu/Clean Model 510 Recirculating Water Deionizer Inline Aqueous Cleaning System for Closed Loop, Zero Discharge Operations Technical Specifications & Pricing The base machine in its standard configuration

More information

PIPE DREAMS 96. Aeroponic Garden IMPORTANT:

PIPE DREAMS 96. Aeroponic Garden IMPORTANT: 1 WARNING: BEFORE PUTTING WATER PUMP INTO OPERATION FILL UP NUTRIENT TANK TO TOP OF PUMP. THE PUMP MUST NEVER RUN DRY OTHERWISE, WARRANTY WILL BE DECLINED. READ FILLING INSTRUCTIONS BEFORE USE. Welcome

More information

TotalPac 3 Firecyle III Deluge Remote controlled system

TotalPac 3 Firecyle III Deluge Remote controlled system (Optional) DESCRIPTION This TOTALPAC 3 integrated fire protection system by FireFlex Systems Inc. consists of a Firecycle III system trim totally preassembled, pre-wired and factory tested. All electrical

More information

J-PRO-22 Pump Proportional Feed Hydrogen Peroxide Installation & Start-Up Guide

J-PRO-22 Pump Proportional Feed Hydrogen Peroxide Installation & Start-Up Guide J-PRO-22 Pump Proportional Feed Hydrogen Peroxide Installation & Start-Up Guide Thank you for purchasing a Clean Water System! Please review this start-up guide entirely before beginning to install your

More information

INSTRUCTIONS REHAU PRO-BALANCE MIXING MODULE

INSTRUCTIONS REHAU PRO-BALANCE MIXING MODULE INSTRUCTIONS REHAU PRO-BALANCE MIXING MODULE SPECIFICATIONS... 1 OVERVIEW... 2 PRECAUTIONS... 2 MOUNTING LOCATION... 2 CONNECTION TO BOILER PRIMARY PIPING:... 3 ELECTRICAL CONNECTION... 4 FLUSHING THE

More information

up to 99% MBTU Models 300A 400A 500A 700A 850A Can be vented with: PVC, Centrotherm New Versa IC TM Platform CSA Certified Low Lead Content

up to 99% MBTU Models 300A 400A 500A 700A 850A Can be vented with: PVC, Centrotherm New Versa IC TM Platform CSA Certified Low Lead Content New Versa IC TM Control Platform up to 99% Efficiency! Can be vented with: PVC, Centrotherm Polypropylene or Stainless Steel. MBTU s 300A 400A 500A 700A 850A CSA Certified Low Lead Content Less Than.25%

More information

HydroCycle Vertical Aeroponic Systems

HydroCycle Vertical Aeroponic Systems HydroCycle Vertical Aeroponic Systems 2018 Growers Supply All Rights Reserved. Reproduction is prohibited without permission. *Actual system may differ from system shown. 113593 8' Vertical System (44

More information

3/4 HP Model Trimmer Operating Instructions

3/4 HP Model Trimmer Operating Instructions 3/4 HP Model Trimmer Operating Instructions Whip Mix Corporation 361 Farmington Ave. P.O. Box 17183 Louisville, KY 40217-0183 USA 502-637-1451 800-626-5651 Fax 502-634-4512 www.whipmix.com Technical Specifications

More information

Water Softener & Single Tank Triple Treat System Installation Overview. Using 1850 Metered Valves

Water Softener & Single Tank Triple Treat System Installation Overview. Using 1850 Metered Valves Water Softener & Single Tank Triple Treat System Installation Overview Using 1850 Metered Valves System Installation CAUTION: Do not use systems on untreated well water that is microbiologically unsafe.

More information

FLOOD KING 120V. 2. Keep all filters clean. Do not operate the machine if the filters are clogged.

FLOOD KING 120V. 2. Keep all filters clean. Do not operate the machine if the filters are clogged. FLOOD KING 120V INFORMATION & OPERATING INSTRUCTIONS DO NOT OPERATE THE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THESE INSTRUCTIONS. IMPROPER USE OF THE MACHINE WILL VOID THE WARRANTY 1. Always be sure

More information

Installation, commissioning and servicing instructions

Installation, commissioning and servicing instructions NA10322.01 www.caleffi.com DIRTMAG dirt separator Copyright 2015 Caleffi NA5453 Series Installation, commissioning and servicing instructions Function In heating and chilled water systems, the circulation

More information

TABLE 1 Electrical Specifications

TABLE 1 Electrical Specifications CHRONOMITE HIGH CAPACITY INSTANT-TEMP WATER HEATERS INSTALLATION AND OPERATION INSTRUCTIONS (208-240V Models) (Before installation, compare electrical requirements needed for the model of heater selected)

More information

Lasco # Description Picture Lasco # Description Picture

Lasco # Description Picture Lasco # Description Picture TOILET REPAIR 02-1755 2 Pack, White Toilet Seat Hinge 663353 Washer, 02-3133 664625 3-1/16 O.D. x 2-1/8 I.D. x 3/16, Close Coupled Sponge Gasket, Toilet Tank To Bowl Gasket, Sponge Rubber Tank To Bowl

More information

Chanson Water USA, INC. Installation Guide for SCF-3000/SCF-6000

Chanson Water USA, INC. Installation Guide for SCF-3000/SCF-6000 Chanson Water USA, INC. Installation Guide for SCF-3000/SCF-6000 Water Dove Systems will not be ready for full use for 48-72 hours after install. Please plan you installation accordingly. Product Spec

More information

COMMERCIAL STRENGTH POLYMER MEDIA FILTER OWNERS MANUAL

COMMERCIAL STRENGTH POLYMER MEDIA FILTER OWNERS MANUAL COMMERCIAL STRENGTH POLYMER MEDIA FILTER OWNERS MANUAL INTRODUCTION Congratulations on choosing the Poolrite S6000 mk2, S5000 mk2, S8000 mk1 or S9000 mk4 High Rate Media Filter fitted with the exclusive

More information

Installation Instructions for. OmniFount

Installation Instructions for. OmniFount Installation Instructions for OmniFount Congratulations, you have just purchased the finest watering fountain on the market. This unit is built to give you excellent service when properly installed and

More information

J-PRO-22 Pump Proportional Feed Chlorinator Installation & Start-Up Guide

J-PRO-22 Pump Proportional Feed Chlorinator Installation & Start-Up Guide J-PRO-22 Pump Proportional Feed Chlorinator Installation & Start-Up Guide Thank you for purchasing a Clean Water System! Please review this start-up guide entirely before beginning to install your system

More information

Hydrotherapy Jets (Remote Water Quality System)

Hydrotherapy Jets (Remote Water Quality System) Page 1 of 6 Parts List (_) - 50 Roll of Flex PVC pipe 1-3/4 HP Circulating Centrifugal Pump 1 25 Roll of Flex PVC pipe 4-1 1 / 2 " Tees 2-1 1 / 2 " Ball Valves 2 - Female slip couplers 4-1/2" 90 degree

More information

VENTURI AIR SPRAYERS 40 FOOT STRAWBERRY AIR BOOM PARTS MANUAL FOR B212/35055/G BOOM FOR P55S1 SPRAYER

VENTURI AIR SPRAYERS 40 FOOT STRAWBERRY AIR BOOM PARTS MANUAL FOR B212/35055/G BOOM FOR P55S1 SPRAYER VENTURI AIR SPRAYERS 40 FOOT STRAWBERRY AIR BOOM PARTS MANUAL FOR B212/35055/G BOOM FOR P55S1 SPRAYER FORM: B21235055GAirBoom April 2014 TABLE OF CONTENTS SECTION DESCRIPTION... PAGE 1 Introduction...1

More information

Natural Action Technologies HOUSE UNIT INSTALLATION INSTRUCTIONS for COPPER, PEX, AND CPVC PIPES USING SHARKBITE CONNECTORS

Natural Action Technologies HOUSE UNIT INSTALLATION INSTRUCTIONS for COPPER, PEX, AND CPVC PIPES USING SHARKBITE CONNECTORS Natural Action Technologies HOUSE UNIT INSTALLATION INSTRUCTIONS for COPPER, PEX, AND CPVC PIPES USING SHARKBITE CONNECTORS Congratulations! You have just received a Natural Action Technologies Structured

More information

LSFG-8 LOW SOUND & SLSFG-10 SUPER LOW SOUND TOWER FEATURES

LSFG-8 LOW SOUND & SLSFG-10 SUPER LOW SOUND TOWER FEATURES The Leaders in All-Fiberglass Cooling Towers REYMSA s success is the result of 35 years of experience in cooling towers. We have been putting ideas into action by researching and developing the latest

More information

Parts and Instruction Manual TRS17 Total Recovery System

Parts and Instruction Manual TRS17 Total Recovery System Parts and Instruction Manual TRS17 Total Recovery System Technical Specifi cations Model TRS17 SPECIFICATIONS: Model Solution Tank Recovery Tank Vacuum Motor Pump Water Lift Tank Construction Baseplate

More information