irritec USA irritec USA THE MODULAR SAND MEDIA FILTER TM Water Tool Filters
|
|
- Jean Jackson
- 5 years ago
- Views:
Transcription
1 irritec
2 The Modular Sand Media Filter is an advanced filtration system, designed from the ground up, especially for media filtration, to provide the ultimate Sand Media Filter. Each Modular Filter Tank is capable of flowing between 15 and 25 gallons per minute depending on the mesh of the sand, coarse or fine sand media. Each Modular Sand Media Filter Tank is self contained with a flush valve. The flush valve can be operated manually or automatic. Automatic Flushing is operated by a Two Wire Back Flush Controller (96 station tanks), thereby keeping the number of wires leaving the controller to the entire Modular Filter System to only two wires. Each Modular Sand Media Filter tank is equipped with a Receiver and Solenoid. The Receiver is coded to receive the code from the controller to operate the Back Flush Valve to that particular tank. As more tanks are added to the system, no extra wires are needed to the controller, only continue the two wire cable to the added tanks. In larger systems, when an abundant amount of Modular Sand Media Filter tanks are used, flushing more than one tank at a time is an option. Up to three tanks can be operated from one back flush solenoid. The Solenoids are plumbed individually with ¼ tubing. This design eliminates all the plumbing and long runs as on other sand media filters. It is designed to be neat, clean and efficient. The Back Flush valve can be unassembled in less than one minute for easy and fast servicing. A unique manifold system makes assembly of the Modular Sand Media Filter a snap to install. All connections are union type and can be hand tightened for easy installation and removal. The design of the Modular Filter is simple and efficient. The Foot Print of the Modular Sand Media Filter system is similar to Steel and Stainless Steel tank media filter systems. Existing sand media filter systems are offered in sizes that sometimes do not fit the gallons required for your system. Those are either too big, causing troublesome back flush or too small causing higher pressure losses. With the Modular Sand Media Filter system you can design the system for the exact gallons per minute required of the system design (plus or minus 20 GPM). If you add to your acreage, simply add the required Modular Sand Media Filter tanks needed no mess, and no fuss. The light weight Modular Sand Media Filter is manufactured of Glass Filled Nylon, a proven material for long life. The Easy Assembly Manifold is manufactured of UVR (Ultra Violet Resistant) PVC. Each Modular Sand Media tank will hold only 5 gallons of the required sand mesh size. An easy fill port is provided on the top of the filter for filling the sand media. There is an easy access port on the bottom of the filter for draining and replacing the media. The unique Modular design of the Sand Media Filter makes back flushing very efficient. For example, on a 480 GPM, 2-48 tank system, back flushing of one tank will take over 50% of the water flow. This lowers the pressure on the system causing slow action of the back flush valve. In some cases an expensive pressure sustaining valve must be used. This is not necessary in a multi tank Modular Sand Media Filter system. This wastes water and causes longer flush times to achieve a maximum cleaning of the filter. With the Modular Sand Media Filter, the back flush system will operate only 1 of the 20 tanks (as compared to a 2-48 tank system), only 5% of the system flow. There will be minimum pressure loss, allowing the flush valve to react quickly and efficiently, with a minimum amount back flush water. The net results being less overall back flush water being used. With back flush flows of approximately 25 GPM, a back flush water recovery system can be utilized at a very low cost, as compared to existing systems on the market today. The Under Drain of the Modular Sand Media Filter is designed especially for this filter, covering 90% of the bottom of the filter. The Under drain back flushes vertically on the upside only. No flow is directed in any direction other than straight up, lifting the filter Media evenly, allowing for the most efficient back flush with a minimum amount of flow available to the market today. The Modular Sand Media Filter is designed to be a Sand Media Filter. It is designed to be water saving efficient. It is light weight, easy to install and easy to maintain. The Modular Sand Media Filter system addresses and corrects the majority of the common faults of existing sand media systems on the market today.
3 Light Weight No Rust - Glass Filled Nylon and UVR PVC Construction Modular Design GPM per Tank - Add as Many Tanks as Needed Minimal Back Flush Water - Individual Back Flush Valves Two Wire Back Flush Controller - 96 Station Back Flush Controller Pressure Switch Similar Foot Print As Existing Sand Media Tanks Back Flush Water Recovery System Available No Pressure Sustaining Valves Needed for Back Flush No Forklifts Needed - Easy Installation Only 5 Gallons of Media Per Tank Available with Groove Inlet / Outlet or Union Connections Supplied with Air Release Valves and Pressure Gauges Full Vertical Underdrain
4 Water Tool Back Flush Controller Hardwire or Solar Power Only Two Wires
5 2 Tank Horizontal
6 3 Tank Horizontal
7 4 Tank Horizontal
8 5 Tank Horizontal
9 6 Tank Horizontal
10 Multiple Tanks in Units of 6 or More - Manifolds Available
11 2 Tank Vertical
12 Flush Flush Flush Flush Flow Out Flow In Flush Flush Flush Flush Typical 48 Tank System 720 gpm gpm (15 gpm each) (25 gpm each)
13 irritec Minimum necessary to remove valve for maintenance / /16" 54-10/16" 30-10/16 12" 15-5/ /16" 12" 14-8/16" 8-15/16" 8-15/ /16" 66-5/8 60-5/16" 33-9/16" 41-1/16" 27-4/16"
14 AUTO FLUSH VALVE UNDERDRAIN UNDERDRAIN ITEM #. QTY. PART #. DESCRIPTION 1 1 WT-154 UNDERDRAIN TEE 2 2 WT-155 UNDERDRAIN O-RING # WT-134 TRIPLE OPEN SEGMENT W / NIPPLE 4 16 WT-133 TRIPLE OPEN SEGMENT 5 2 WT-132 TRIPLE CLOSED / OPEN SEGMENT 6 64 WT-131 SMALL OPEN SEGMENT 7 2 WT-130 SMALL CLOSED SEGMENT 8 12 WT-144 SEGMENT NUT WT-135 SEGMENT BOLT # X WT-136 SEGMENT BOLT # X WT-137 SEGMENT BOLT # X AUTO FLUSH VALVE ITEM #. QTY. PART #. DESCRIPTION 1 1 WT-113 BACK FLUSH LOWER BODY SS SCREWS 3 1 WT-115 #202 - BACK FLUSH O-RING 4 1 WT-116 BACK FLUSH SEAT 5 1 WT-111 1/4 SS ROD 6 1 WT-117 BACK FLUSH SPRING BACK FLUSH DIAPHRAGM 8 1 WT-120 DIAPHRAGM SUPPORT 9 2 WT-145 1/4-28 SS NYLON NUT /4-28 SS NUT 11 1 WT-114 BACK FLUSH UPPER BODY 12 6 WT-146 BACK FLUSH BOLT 13 1 WT /2 UVR SCH 80 TEE 14 1 WT-112 BACK FLUSH ADAPTER 15 1 WT /2 X 2 ADAPTER 17 1 WT /2 UNION NUT 18 1 WT-109 DIAPHRAGM SEAT 19 1 WT-108 SEAT RETAINER BRASS INSERT 21 1 WT-107 VALVE UPPER BODY 22 1 WT-106 VALVE LOWER BODY 23 2 WT /2 UNION MALE THREAD 24 1 WT-159 VALVE UPPER BODY O-RING #227
15 Product List Part Number Description Inlet Outlet Back Flush Back Flush Flow GPM Flow L/M L WT-2HGA 2 Tank Horizontal Groove Groove Union Automatic WT-2HGM 2 Tank Horizontal Groove Groove Union Manual WT-2HUA 2 Tank Horizontal Union Union Union Automatic WT-2HUM 2 Tank Horizontal Union Union Union Manual WT-2VUA 2 Tank Vertical Union Union Union Automatic WT-2VUM 2 Tank Vertical Union Union Union Manual WT-3HGA 3 Tank Horizontal Groove Groove Union Automatic WT-3HGM 3 Tank Horizontal Groove Groove Union Manual WT-3HUA 3 Tank Horizontal Union Union Union Automatic WT-3HUM 3 Tank Horizontal Union Union Union Manual WT-4HGA 4 Tank Horizontal Groove Groove Union Automatic WT-4HGM 4 Tank Horizontal Groove Groove Union Manual WT-4HUA 4 Tank Horizontal Union Union Union Automatic WT-4HUM 4 Tank Horizontal Union Union Union Manual WT-5HGA 5 Tank Horizontal Groove Groove Union Automatic WT-5HGM 5 Tank Horizontal Groove Groove Union Manual WT-5HUA 5 Tank Horizontal Union Union Union Automatic WT-5HUM 5 Tank Horizontal Union Union Union Manual WT-6HGA 6 Tank Horizontal Groove Groove Union Automatic WT-6HGM 6 Tank Horizontal Groove Groove Union Manual WT-6HUA 6 Tank Horizontal Union Union Union Automatic WT-6HUM 6 Tank Horizontal Union Union Union Manual
16 irritec Distributed by: irritec 4450 N. Brawley Ave. SUITE 126 Fresno, CA Toll Free (877) Tel (559) Fax (559)
OSCAR-LOWeFLOW Treatment System Design Manual October 2016
!! OSCAR-LOWeFLOW Treatment System Design Manual October 2016 (Patent Number 8,889,007 & Patent Pending) Manufactured by: Lowridge Onsite Technologies PO Box 1179 Lake Stevens, WA 98258 877 476-8823 info@lowridgetech.com!1
More information215 Gallon Waste Oil Tank With Bypass Regulator Installation Instructions
215 Gallon Waste Oil Tank With Bypass Regulator Installation Instructions Lanair Products LLC 4109 Capital Circle Janesville, Wisconsin 53546 1-888-370-6531 www.lanair.com BEFORE YOU BEGIN INSTALLATION...
More informationMODEL CMA-180UC PARTS MANUAL Rev 1.16
MODEL CMA-180UC PARTS MANUAL Rev 1.16 CMA DISHMACHINES 12700 KNOTT STREET GARDEN GROVE, CALIFORNIA 92841 800-854-6417 FAX 714-895-2141 wwwcmadishmachines.com TABLE OF CONTENTS MODEL CMA-180UC 1. PARTS
More informationWM-450-PT WM-900-PT Commercial Wall Mounted Reverse Osmosis
WM-450-PT WM-900-PT Commercial Wall Mounted Reverse Osmosis Installation And Service Manual Watts Pure Water 1725 W. Williams Dr. C-20., Phoenix, Arizona 85027 Phone: 888-774-7405 Fax: 602-588-0356 www.wattspurewater.com
More informationmodel NO. LSS GALLON SKID MOUNTED HIGH PRESSURE SPRAYER ASSEMBLY / OPERATION INSTRUCTIONS / PARTS
000 model NO. LSS- 00 GALLON SKID MOUNTED HIGH PRESSURE SPRAYER ASSEMBLY / OPERATION INSTRUCTIONS / PARTS Part number and descriptions can be obtained from the illustrated parts list section of this manual.
More informationOSCAR-LOWeFLOW Treatment System Design Manual January 2018
! OSCAR-LOWeFLOW Treatment System Design Manual January 2018 Manufactured by: Lowridge Onsite Technologies PO Box 1179 Lake Stevens, WA 98258 877 476-8823 info@lowridgetech.com!1 Introduction: This manual
More informationMODELS CMA-180 VL/180 VLTall PARTS MANUAL Rev 2.02A
MODELS CMA-180 VL/180 VLTall PARTS MANUAL Rev 2.02A C M A D I S H M A C H I N E S 1 2 7 0 0 K N O T T A V E N U E GARDEN GROVE, CALIFORNIA 92841 800-8 5 4-6 4 1 7 FAX 714-895-2141 www.cmadishmachines.com
More informationREPLACEMENT PARTS MANUAL FOR MODEL: PWS 45-75, AED-2 & APK-4 SERIES
PREC SION Water Systems REPLACEMENT PARTS MANUAL FOR MODEL: PWS 45-75, AED-2 & APK-4 SERIES 0004 0002 0001 PRECISION WATER SYSTEMS WATER DISTILLER MANUFACTURED BY: PRECISION DESIGN & MANUFACTURING INC.
More informationMODEL CMA-180UC PARTS MANUAL Rev 1.18
MODEL CMA-180UC PARTS MANUAL Rev 1.18 CMA DISHMACHINES 12700 KNOTT AVENUE GARDEN GROVE, CALIFORNIA 92841 800-854-6417 FAX 714-895-2141 wwwcmadishmachines.com TABLE OF CONTENTS MODEL CMA-180UC 1. PARTS
More informationInstallation Instructions
Installation Instructions 6 KW and 11.5KW Basic Circulation Water Heater and Pump Application: The Basic Circulation Water Heater has been in use for nearly 50 years, and it is the most prevalent model
More informationMODELS CMA-180 VL/180 VLTall PARTS MANUAL Rev 2.02B
MODELS CMA-180 VL/180 VLTall PARTS MANUAL Rev 2.02B C M A D I S H M A C H I N E S 1 2 7 0 0 K N O T T A V E N U E GARDEN GROVE, CALIFORNIA 92841 800-8 5 4-6 4 1 7 FAX 714-895-2141 www.cmadishmachines.com
More informationAer-Max Installation Instructions
Aer-Max Installation Instructions Congratulations on selecting this quality Aer-Max system. Important: Please read all instructions before assembling and installing the Aer-Max system. Consult local plumbing
More informationJ120 STEAM BOOSTER INSTALLATION, OPERATION, AND SERVICE MANUAL J120 STEAM BOOSTER. J120 Steam Booster Manual D
INSTALLATION, OPERATION, AND SERVICE MANUAL J120 STEAM BOOSTER J120 STEAM BOOSTER J120 Steam Booster Manual REVISION HISTORY Revision Letter Revision Date Made by Applicable ECNs Details A 10-27-04 CBW
More informationOwner's Manual. (200 Gallon Lawn Service Skid Sprayer) Technical Specifications. Operation. General Information. Warranty/Parts/Service
Owner's Manual (00 Gallon Lawn Service Skid Sprayer) Technical Specifications. Horsepower Recoil Start Engine Roller Cast Iron Pump 0 Gallons Per Minute at 0 PSI Pressure Gauge-Adjustable Pressure Range
More informationOSCAR-LOWeFLOW Treatment System Design Manual August 2017
! OSCAR-LOWeFLOW Treatment System Design Manual August 2017 Manufactured by: Lowridge Onsite Technologies PO Box 1179 Lake Stevens, WA 98258 877 476-8823 info@lowridgetech.com!1 Introduction: The OSCAR
More informationClean Water Made Easy. CWS Time Clock Softener Installation & Start Up Guide. Questions?
Clean Water Made Easy www.cleanwaterstore.com CWS Time Clock Softener Installation & Start Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance
More informationMODEL CMA-180UC SERVICE & PARTS MANUAL Rev 1.10
MODEL CMA-180UC SERVICE & PARTS MANUAL Rev 1.10 CMA DISHMACHINES 12700 KNOTT AVENUE GARDEN GROVE, CALIFORNIA 92841 800-854-6417 FAX 714-895-2141 www.cmadishmachines.com 0203 TABLE OF CONTENTS MODEL CMA-180UC
More informationREPLACEMENT PARTS MANUAL
PREC SION Water Systems REPLACEMENT PARTS MANUAL FOR MODEL: PWS 12-20(120VAC), PWS 12-20(240VAC), AED-1(120VAC), AED-1(240VAC), APK-1(120VAC) & APK-1(240VAC) PART # 510001 510003 500006 500015 500007 500016
More informationWARNING DESCRIPTION PART NUMBER QTY PLUMBING, DYNATEMP DRAIN QUENCH BRACKET, THERMOSTAT DRAIN QUENCH
! WARNING WARNING: This kit should be installed only by qualified service personnel to reduce the risk of electric shock, serious injury, or fire. A plumbing permit and the services of a licensed plumber
More informationCMA Dishmachines Knott Avenue Garden Grove, CA Undercounter High Temperature Dishwasher. Service Replacement Parts.
CMA Dishmachines 1700 Knott Avenue Garden Grove, CA 981 Toll Free: 1- (800) 8-617 Fax: 1- (71) 89-11 Service Replacement Parts Undercounter High Temperature Dishwasher Model: UC6e M Machine Serial No.
More informationREPLACEMENT PARTS MANUAL
PREC SION Water Systems REPLACEMENT PARTS MANUAL FOR MODEL: PWS 8-8(120VAC), PWS 8-8(240VAC), AED-1(120VAC), AED-1(240VAC), APK-1(120VAC) & APK-1(240VAC) PART # 500003 500014 500006 500015 500007 500016
More informationJOHN DEERE GATOR HPX/XUV 2 PASSENGER HEATER INSTALLATION INSTRUCTIONS (p/n: 9PH20S30)
P. 1 of 12 JOHN DEERE GATOR HPX/XUV 2 PASSENGER HEATER INSTALLATION INSTRUCTIONS (p/n: 9PH20S30) Item: Qty: Description: 1 2 1 x 1 x 5/8 Tee Fitting 2 2 Plastic Snap-in Hose Grommet 3 4 1-1/2" Hose Clamps
More informationJ-PRO V 230V Dual Voltage Hydrogen Peroxide Pump Installation & Start-Up Guide
J-PRO-22 110V 230V Dual Voltage Hydrogen Peroxide Pump Installation & Start-Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance, your system
More informationGeneral System Layout Sketch
General System Layout Sketch SW-38 Solar Panel(s) Hot Water Cold Water PV panel Glycol RV Water Heater WITH built in Heat Exchanger Water Ports ` Glycol Fill Valve 1 Pump Solar Powered Expansion Tank Glycol
More informationSemi-Automatic Suction Screen Filters 3"-4 Angle. Service & Maintenance Manual
Semi-Automatic Suction Screen Filters 3"-4 Angle Service & Maintenance Manual Safety Instructions Prior to installation or handling of the filter, read the Installation and Operation instructions carefully.
More informationHigh Capacity Instantaneous Steam Fired Water Heater
MODEL F High Capacity Instantaneous Steam Fired Water Heater Features Compact High Capacity Design Packaged System Water heater is factory assembled on an all welded steel mounting frame to save time and
More informationF-P, F-L, FT-P AND FT-L SERIES 2/3 JACKETED DIRECT STEAM TILTING & STATIONARY KETTLES PARTS AND SERVICE MANUAL
F-P, F-L, FT-P AND FT-L SERIES 2/3 JACKETED DIRECT STEAM TILTING & STATIONARY KETTLES PARTS AND SERVICE MANUAL EFFECTIVE NOVEMBER 2, 2015 Superseding All Previous Parts Lists. The Company reserves the
More informationWARNING. Failure to install this kit within the guidelines might adversely affect safety, performance, component life and warranty coverage.
! WARNING WARNING: This kit should be installed only by qualified service personnel to reduce the risk of electric shock, serious injury, or fire. A plumbing permit and the services of a licensed plumber
More informationJ-PRO V 230V Dual Voltage Chlorinator Installation & Start-Up Guide
J-PRO-22 110V 230V Dual Voltage Chlorinator Installation & Start-Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance, your system will be providing
More informationFILTRATION SYSTEM MODEL: FILTER - 5 MULTI-SHIFTER, INC. P.O. BOX CHARLOTTE, N.C TEL#: FAX#:
FILTRATION SYSTEM MODEL: FILTER - 5 MULTI-SHIFTER, INC. P.O. BOX 411047 CHARLOTTE, N.C. 28241-1047 TEL#: 1-704-588-9611 FAX#: 1-704-588-4730 CONTENTS 1. System Overview 2. Air and Electrical Requirements
More informationCare and Use Manual Tank Series Appliances
Care and Use Manual Tank Series Appliances 4.4-1 Information Provided for the Proper Set-Up, Installation and Start-Up of the following Appliances: EWS Series of Whole Home Filtration and Physical Conditioning:
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS VARIABLE SPEED BOOSTER PUMP IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS IMPORTANT SAFETY INFORMATION WARNING: RISK OF ELECTRICAL SHOCK
More informationParagon PW750F two stage Drinking Water Filtration System Installation & Operation Manual
Paragon PW750F two stage Drinking Water Filtration System Installation & Operation Manual Marketed & Distributed in Singapore by: Quantum Impact Pte Ltd (UEN 201014570H) Add:16 Raffles Quay, #41-07, Hong
More informationREPLACEMENT PARTS MANUAL
PREC SION Water Systems REPLACEMENT PARTS MANUAL FOR MODEL: PWS 8-5(120VAC), PWS 8-5(240VAC), AED-1(120VAC), AED-1(240VAC), APK-2(120VAC) & APK-2(240VAC) PART # 500002 500013 500006 500015 500008 500017
More informationOPERATING AND MAINTENANCE MANUAL FOR INSTANTANEOUS STEAM FIRED WATER HEATER ELECTRIC HEATER COMPANY BASE MODEL F
OPERATING AND MAINTENANCE MANUAL FOR INSTANTANEOUS STEAM FIRED WATER HEATER ELECTRIC HEATER COMPANY BASE MODEL F Edition 2013 HUBBELL ELECTRIC HEATER COMPANY P.O. BOX 288 STRATFORD, CT 06615 PHONE: (203)
More informationPolymer Dilution Blend and Feed Specifications For General Use
Polymer Dilution Blend and Feed Specifications For General Use Electronic Diaphragm Metering Pump 1.0 GENERAL The contractor shall furnish and install polymer dilution blending and feeding units together
More informationOwner s Manual GLC MANUAL INSTALLATION SERVICE PARTS REV.1.00
Owner s Manual GLC MANUAL INSTALLATION SERVICE PARTS REV.1.00 C M A D I S H M A C H I N E S 1 2 7 0 0 K N O T T S T R E E T GARDEN GROVE, CALIFORNIA 92841 800-8 5 4-6 4 1 7 F A X 7 1 4-8 9 5-2141 www.cmadishmachines.com
More informationHanging Basket Watering Systems
Hanging Basket Watering Systems A Labor Saving Drip System for Watering Hanging Baskets Lower Input Costs Increases Profitability Hanging Basket growers needing to reduce or eliminate their hand watering
More informationOwner s Manual GW-100 MANUAL INSTALLATION SERVICE PARTS REV.1.00
Owner s Manual GW-100 MANUAL INSTALLATION SERVICE PARTS REV.1.00 C M A D I S H M A C H I N E S 1 2 7 0 0 K N O T T S T R E E T GARDEN GROVE, CALIFORNIA 92841 800-8 5 4-6 4 1 7 F A X 7 1 4-8 9 5-2141 www.cmadishmachines.com
More informationModel AV Alarm Valve With and Without Model RC-1 Retard Chamber European Conformity Valve Trim General Description
Worldwide Contacts www.tyco-fire.com Model AV--00 Alarm Valve With and Without Model RC- Retard Chamber European Conformity Valve Trim General Description The TYCO Model AV--00 Alarm Valves DN, DN0, DN0,
More informationA B A B4
TM TM SERVICE INSTRUCTIONS Thermo-Aire Heater Kits and Air-Heater Assemblies 383808-A4 383808-B4 383880-A4 383880-B4 DESCRIPTION The Thermo-Aire Heater is used in situations where oils of heavier viscosity
More informationNOTE: Parts are no longer available for this tool. The manual will continue on the next page.
NOTE: Parts are no longer available for this tool. The manual will continue on the next page. ------------------------------------------------- CATALOG NO. 7628 Form No. Z21 0 Date 1-93 High Pressure Power
More informationSafety. Rinse Kit for Multi-Pro 1200 and 1250 Turf Sprayers Model No Safety and Instructional Decals. Installation Instructions
Rinse Kit for Multi-Pro 1200 and 1250 Turf Sprayers Model No. 106-4842 Form No. 3353-529 Rev B Installation Instructions Note: Determine the left and right sides of the machine from the normal operating
More informationOwner s Manual. Keep with machine for reference PKC24 INSTALLATION & OPERATION REV Perlick Corporation 8300 W Good Hope Rd Milwaukee, WI 53223
Owner s Manual Keep with machine for reference PKC24 INSTALLATION & OPERATION REV.11.09 Perlick Corporation 8300 W Good Hope Rd Milwaukee, WI 53223 800-558- 5592 FAX 414-353- 7069 perlick.com TABLE OF
More informationModel 10AB/APRB Automatic Dishwasher
Model 10AB/APRB Automatic Dishwasher Rinse and Wash Head Assemblies ITEM 1 0126800 End Plug 2 0125000 Rinse Arm Body (only) 3 0126000 Nylatron Washer (2 places) 4 0125500 Hex Nut 5 0126500 Snap Ring 6
More informationGLC/GW-100 MANUAL INSTALLATION SERVICE PARTS REV.1.01
Owner s Manual Keep with machine for reference GLC/GW-100 MANUAL INSTALLATION SERVICE PARTS REV.1.01 CMA DISHMACHINES 12700 KNOTT STREET GARDEN GROVE, CALIFORNIA 92841 800-854- 6417 FAX 714-895- 2141 www.cmadishmachines.com
More informationGeneral System Layout Sketch
General System Layout Sketch EZ-37 Solar Panels PV panel Glycol Fill Valve Expansion Tank ` 1 Introduction This document describes how to install a Heliatos GH type solar water heating system. These systems
More informationDAD-500 (130026) DESICCANT AIR DRYING SYSTEM
SERVICE BULLETIN SB---O Replaces SB---N DAD-00 (00) DESICCANT AIR DRYING SYSTEM Air In 0 The CFM DAD-00 Desiccant Air Drying System is designed to be a point of use system. It is capable of removing dirt,
More information541D19 SERIES. Technical Manual. A Division of Aquion Partners L.P.
541D19 SERIES Technical Manual A Division of Aquion Partners L.P. Table of Contents Introduction... Page 1 Technical Specifications... Page 2 Flow Diagrams... Page 3 Injector & Flow Control Selection Injector...
More informationKinetico 2060f OD Sulfur Guard Installation Instructions
SAFETY GUIDELINES Read all steps, guides, and rules carefully before installing and using the Kinetico 2060f OD Sulfur Guard. Check your local building and sanitation codes for installation compliance.
More informationParts Manual Vermeer/McLaughlin V500LTHD Vacuum Machine Part #E (SERIAL # 5DHDLT _5DHDLT )
006 Perimeter Road. Greenville, SC 9605 Toll Free: 800/5-90 - Phone: 86/77-5870 Fax: 86/5-9661 - Website address: www.mightymole.com Email address: mmole@mightymole.com Parts Manual Vermeer/McLaughlin
More informationSEA FROST BAITFREEZER 110-VOLT AIR-WATER Twin Valve
372 ROUTE 4 BARRINGTON, NH 03825 USA TEL (603) 868-5720 FAX (603) 868-1040 1-800-435-6708 E-Mail:sales@seafrost.com www.seafrost.com SEA FROST BAITFREEZER 110-VOLT AIR-WATER Twin Valve Operation and Installation
More informationInstructions CH Chrome SS Stainless Steel Certifications. Single Handle, Pull-Down, Kitchen Faucet. Tools Required.
Instructions *Image may vary slightly from actual product Tools Required Adjustable Wrench Groove Joint Pliers Pipe Wrench Phillips Screwdriver Pipe Tape or pipe thread compound Safety Tips If you solder
More informationOSCAR-LOWeFLOW Treatment Unit Installation Manual. January Residential
OSCAR-LOWeFLOW Treatment Unit Installation Manual January 2016 Residential US Patent # 8,889,007 Manufactured by: Lowridge Onsite Technologies, LLC PO Box 1179 Lake Stevens, WA 98258 877-476-8823 info@lowridgetech.com
More informationSERIES WATERERS INSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS Read and study entire booklet carefully before beginning installation. Use only Nelson accessories and replacement parts. Save this booklet. Call if you have questions. SERIES
More informationParts & Material Included
O² Hydro Well System Installation, Use & Care Guide Parts & Material Included 1. Funnel 11. Drain Line 21. Air Head 2. Media Tank Distributer Tube 12. Air Release 22. Drain Fitting 3. Air Tank Distributer
More informationSeries 20 Dual Check Backflow Preventers
Series 20 Dual Check Backflow Preventers Excellence Matters Specify It! A Division of Watts Regulator Company 427 North Market Blvd Suite #9 Sacramento, CA 9584 Phone: 96-928-02 Fax: 96-928-9 www.amesfirewater.com
More information4-1 1 / 2 " Tees / 2 " hole saw w/ 1/4" drill bit / 2 " Male slip plugs
Section 1: Parts List 1-50 Flex PVC pipe 2-1 1 / 2 " Ball Valves 4-1/2" 90 degree elbows 4 - Lengths of 1/2" PVC 4 - Jet bodies 4 - Jet nozzles 4 - Female slip/female slip unions 2 - Female slip/fpt union
More informationIMAGE V. Parts and Service Manual
IMAGE 0V Section II Parts and Service Manual (88B) CLARKE TECHNOLOGY Image Operator's Manual Page AUTHORIZED PERSONNEL MAINTENANCE To Access Pump Motor. Remove brush housing from machine. See "Brush Motor
More informationKPS-DS, KLS-DS, KPT-DS AND KLT-DS SERIES 2/3 JACKETED DIRECT STEAM TILTING & STATIONARY KETTLES PARTS AND SERVICE MANUAL
KPS-DS, KLS-DS, KPT-DS AND KLT-DS SERIES 2/3 JACKETED DIRECT STEAM TILTING & STATIONARY KETTLES PARTS AND SERVICE MANUAL EFFECTIVE NOVEMBER 2, 2015 Superseding All Previous Parts Lists. The Company reserves
More information(Toll Free); 7am-7pm Pacific Time, Monday-Saturday. Assembly instructions for: DUSTIN S FACE TO FACE GLIDERS WITH XW ROOF
866.332.2403 (Toll Free); 7am-7pm Pacific Time, Monday-Saturday Assembly instructions for: DUSTIN S FACE TO FACE GLIDERS WITH XW ROOF FRAME QUANTITY DRAWING 2 Structure Supports 2 Supports 1 Base support
More informationFigure 1 - Steam Generator. Electrical Installation Instructions. 01/09 Pub. No. 200-A - 1 -
Electrical Installation Instructions C US Steambath Generators The Steamist TSG Generator operates with a TSC control mounted inside and optional TSR remote control located outside the steamroom. It s
More informationWhirlpool Spa PARTS CATALOG MODEL #F ISSUE DATE: 6/95 CATALOG #G766000
The LEXUS TM L.C. Whirlpool Spa PARTS CATALOG MODEL #F9000 ISSUE DATE: /9 CATALOG #G000 CONTENTS Lexus L. C. Reference Discharge Plumbing Discharge Plumbing (Continued) Suction Plumbing Air Line Piping
More informationPARTS STOCKED REPLACEMENT FAUCET BIBB SCREWS... SCREW ASSORTMENT MISC. 3 /8" BIBB LOC SCREW 1 /2" BIBB SCREW 1 /2" BIBB LOC SCREW 3 /8" BIBB SCREW
January 1, 2001 STOCKED REPLACEMENT FAUCET BIBB SCREWS... Parts-5L 3 /8" BIBB SCREW 6-32 GAUGE CHROME 35138- No. 1 3 /8" BIBB SCREW 10-24 GAUGE CHROME 35153- No. 16 3 /8" BIBB SCREW 8-32 GAUGE CHROME 35141-
More informationInstruction Sheet AquaMotionHot One AMH1K-1 Point of Use Hot Water Recirculation System
Effective: 5/13/15 Supersedes: New IS-AM09-601 Instruction Sheet Point of Use Hot Water Recirculation System THANK YOU for purchasing a new Aquamotion Hot System! For optimum reliability and performance
More informationInstructions. 110-KVD-CYSCH-AD-Z Chrome 110-KVD-CYSSS-AD-Z Stainless Steel Certifications. Single Handle, Pull-Down, Kitchen Faucet
Instructions *Image may vary slightly from actual product Tools Required Adjustable Wrench Groove Joint Pliers Pipe Wrench Phillips Screwdriver Pipe Tape or pipe thread compound Safety Tips If you solder
More informationInstallation Instructions for. OmniFount
Installation Instructions for OmniFount Congratulations, you have just purchased the finest watering fountain on the market. This unit is built to give you excellent service when properly installed and
More informationWS1 Softener Installation & Start-Up Guide
WS1 Softener Installation & Start-Up Guide Thank you for purchasing a Van Isle Conditioner. With proper installation and a little routine maintenance your system will be providing treated water for many
More informationLavatory Faucet INSTALLATION INSTRUCTIONS P24490-CR, P24490-LV, P24491-CR, P24491-LV, P24492-CR, P24492-LV, P24700, P24705, P24706, P24736, P24800
P24490-CR, P24490-LV, P24491-CR, P24491-LV, P24492-CR, P24492-LV, P24700, P24705, P24706, P24736, P24800 2018 1 of 7 KALLISTA THANK YOU FOR CHOOSING KALLISTA We appreciate your commitment to KALLISTA quality
More informationCALEFFI. SEP4 combination hydraulic, air, dirt and magnetic separator series 01249/13.1 NA. Replaces 01249/13 NA. Function.
SEP4 combination hydraulic, air, dirt and magnetic separator 5495 series CCREDITED ISO 9001 FM 21654 ISO 9001 No. 0003 CLEFFI 01249/13.1 N Replaces 01249/13 N Product range Function combination hydraulic,
More informationINSTALLATION INSTRUCTIONS
,t_2007 Lennox Industries Inc. Dallas, Texas, USA INSTALLATION INSTRUCTIONS CH33 Series Units EVAPORATOR 505,264M (65484504) 10/07 Supersedes 09/06 COILS n _putech blications ical Litho U.S.A. RETAIN THESE
More informationINDUSTRIAL CONDENSATE POLISHERS. LWTCP Series
INDUSTRIAL CONDENSATE POLISHERS 150,000 TO 3,000,000 GRAINS CAPACITY (Sodium Cycle) Optimum Efficiency And Proven Reliability 1 P a g e Condensate Polishers are important in systems treating condensed
More informationE. F. G. H. I. J. K. L. M. Alternate Energy Technologies, LLC. P F
UDX No Sweat Kit instuctions The No Sweat Kit is intended to be used in conjunction with the AET s DB-10-10XC and DB-15-15XC on a 120 or 80 gallon OST (American Water Heater) top or side connect tank.
More informationStandard Tank One (Approximately 1500 gallons)
Standard Tank One (Approximately 1500 gallons) 11' 0" 6" PVC tee Cap / Clean out From Bay Drain See Note 2 1-1/4 Ozone return Line, terminate with a tee 6 Tee 6 PVC To Tank Two See Note 3 6 Transfer 5'
More informationROTARY VANE VACUUM PUMPS Exploded View DuraVane Rotary Vane Pumps Oil-Lubricated RVL301HH
Exploded View Pumps RVL0HH 95 SOUTH WOODLAND AVENUE, MICHIGAN CITY, IN 0-57 Please visit our website at Page Number Reference TOLL-FREE: 888-95-5 TEL.: 9-8-0 FAX: 9-8-0 www.dekkervacuum.com DWG //05 RVL0HH
More informationInstallation Instructions PRO SERIES
Installation Instructions PRO SERIES If you are a plumber installing this unit, please leave this owners manual & warranty card with the owner when you finish the installation. Thank You! DO NOT USE THIS
More informationINSTALLATION OF DURAVENT POLYPRO SINGLE WALL POLYPROPYLENE VENTING SYSTEMS
SUPPLEMENT VENTING INSTRUCTIONS FOR INSTALLATION AND OPERATION INSTRUCTION MANUALS FOR THE FOLLOWING PRODUCT TYPES: HIGH EFFICIENCY CONDENSING COMMERCIAL, COMMERCIAL POWER DIRECT VENT, LIGHT DUTY COMMERCIAL
More informationDIRTMAG dirt separator with magnet, adjustable for vertical or horizontal pipe
DIRTMAG dirt separator with magnet, adjustable for vertical or horizontal pipe Copyright 206 Caleffi NA0322.02 www.caleffi.com NA5453 Series Installation, commissioning and servicing instructions Function
More informationTechnical Specifications & Pricing
Nu/Clean Model 510 Recirculating Water Deionizer Inline Aqueous Cleaning System for Closed Loop, Zero Discharge Operations Technical Specifications & Pricing The base machine in its standard configuration
More informationPIPE DREAMS 96. Aeroponic Garden IMPORTANT:
1 WARNING: BEFORE PUTTING WATER PUMP INTO OPERATION FILL UP NUTRIENT TANK TO TOP OF PUMP. THE PUMP MUST NEVER RUN DRY OTHERWISE, WARRANTY WILL BE DECLINED. READ FILLING INSTRUCTIONS BEFORE USE. Welcome
More informationTotalPac 3 Firecyle III Deluge Remote controlled system
(Optional) DESCRIPTION This TOTALPAC 3 integrated fire protection system by FireFlex Systems Inc. consists of a Firecycle III system trim totally preassembled, pre-wired and factory tested. All electrical
More informationJ-PRO-22 Pump Proportional Feed Hydrogen Peroxide Installation & Start-Up Guide
J-PRO-22 Pump Proportional Feed Hydrogen Peroxide Installation & Start-Up Guide Thank you for purchasing a Clean Water System! Please review this start-up guide entirely before beginning to install your
More informationINSTRUCTIONS REHAU PRO-BALANCE MIXING MODULE
INSTRUCTIONS REHAU PRO-BALANCE MIXING MODULE SPECIFICATIONS... 1 OVERVIEW... 2 PRECAUTIONS... 2 MOUNTING LOCATION... 2 CONNECTION TO BOILER PRIMARY PIPING:... 3 ELECTRICAL CONNECTION... 4 FLUSHING THE
More informationup to 99% MBTU Models 300A 400A 500A 700A 850A Can be vented with: PVC, Centrotherm New Versa IC TM Platform CSA Certified Low Lead Content
New Versa IC TM Control Platform up to 99% Efficiency! Can be vented with: PVC, Centrotherm Polypropylene or Stainless Steel. MBTU s 300A 400A 500A 700A 850A CSA Certified Low Lead Content Less Than.25%
More informationHydroCycle Vertical Aeroponic Systems
HydroCycle Vertical Aeroponic Systems 2018 Growers Supply All Rights Reserved. Reproduction is prohibited without permission. *Actual system may differ from system shown. 113593 8' Vertical System (44
More information3/4 HP Model Trimmer Operating Instructions
3/4 HP Model Trimmer Operating Instructions Whip Mix Corporation 361 Farmington Ave. P.O. Box 17183 Louisville, KY 40217-0183 USA 502-637-1451 800-626-5651 Fax 502-634-4512 www.whipmix.com Technical Specifications
More informationWater Softener & Single Tank Triple Treat System Installation Overview. Using 1850 Metered Valves
Water Softener & Single Tank Triple Treat System Installation Overview Using 1850 Metered Valves System Installation CAUTION: Do not use systems on untreated well water that is microbiologically unsafe.
More informationFLOOD KING 120V. 2. Keep all filters clean. Do not operate the machine if the filters are clogged.
FLOOD KING 120V INFORMATION & OPERATING INSTRUCTIONS DO NOT OPERATE THE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THESE INSTRUCTIONS. IMPROPER USE OF THE MACHINE WILL VOID THE WARRANTY 1. Always be sure
More informationInstallation, commissioning and servicing instructions
NA10322.01 www.caleffi.com DIRTMAG dirt separator Copyright 2015 Caleffi NA5453 Series Installation, commissioning and servicing instructions Function In heating and chilled water systems, the circulation
More informationTABLE 1 Electrical Specifications
CHRONOMITE HIGH CAPACITY INSTANT-TEMP WATER HEATERS INSTALLATION AND OPERATION INSTRUCTIONS (208-240V Models) (Before installation, compare electrical requirements needed for the model of heater selected)
More informationLasco # Description Picture Lasco # Description Picture
TOILET REPAIR 02-1755 2 Pack, White Toilet Seat Hinge 663353 Washer, 02-3133 664625 3-1/16 O.D. x 2-1/8 I.D. x 3/16, Close Coupled Sponge Gasket, Toilet Tank To Bowl Gasket, Sponge Rubber Tank To Bowl
More informationChanson Water USA, INC. Installation Guide for SCF-3000/SCF-6000
Chanson Water USA, INC. Installation Guide for SCF-3000/SCF-6000 Water Dove Systems will not be ready for full use for 48-72 hours after install. Please plan you installation accordingly. Product Spec
More informationCOMMERCIAL STRENGTH POLYMER MEDIA FILTER OWNERS MANUAL
COMMERCIAL STRENGTH POLYMER MEDIA FILTER OWNERS MANUAL INTRODUCTION Congratulations on choosing the Poolrite S6000 mk2, S5000 mk2, S8000 mk1 or S9000 mk4 High Rate Media Filter fitted with the exclusive
More informationInstallation Instructions for. OmniFount
Installation Instructions for OmniFount Congratulations, you have just purchased the finest watering fountain on the market. This unit is built to give you excellent service when properly installed and
More informationJ-PRO-22 Pump Proportional Feed Chlorinator Installation & Start-Up Guide
J-PRO-22 Pump Proportional Feed Chlorinator Installation & Start-Up Guide Thank you for purchasing a Clean Water System! Please review this start-up guide entirely before beginning to install your system
More informationHydrotherapy Jets (Remote Water Quality System)
Page 1 of 6 Parts List (_) - 50 Roll of Flex PVC pipe 1-3/4 HP Circulating Centrifugal Pump 1 25 Roll of Flex PVC pipe 4-1 1 / 2 " Tees 2-1 1 / 2 " Ball Valves 2 - Female slip couplers 4-1/2" 90 degree
More informationVENTURI AIR SPRAYERS 40 FOOT STRAWBERRY AIR BOOM PARTS MANUAL FOR B212/35055/G BOOM FOR P55S1 SPRAYER
VENTURI AIR SPRAYERS 40 FOOT STRAWBERRY AIR BOOM PARTS MANUAL FOR B212/35055/G BOOM FOR P55S1 SPRAYER FORM: B21235055GAirBoom April 2014 TABLE OF CONTENTS SECTION DESCRIPTION... PAGE 1 Introduction...1
More informationNatural Action Technologies HOUSE UNIT INSTALLATION INSTRUCTIONS for COPPER, PEX, AND CPVC PIPES USING SHARKBITE CONNECTORS
Natural Action Technologies HOUSE UNIT INSTALLATION INSTRUCTIONS for COPPER, PEX, AND CPVC PIPES USING SHARKBITE CONNECTORS Congratulations! You have just received a Natural Action Technologies Structured
More informationLSFG-8 LOW SOUND & SLSFG-10 SUPER LOW SOUND TOWER FEATURES
The Leaders in All-Fiberglass Cooling Towers REYMSA s success is the result of 35 years of experience in cooling towers. We have been putting ideas into action by researching and developing the latest
More informationParts and Instruction Manual TRS17 Total Recovery System
Parts and Instruction Manual TRS17 Total Recovery System Technical Specifi cations Model TRS17 SPECIFICATIONS: Model Solution Tank Recovery Tank Vacuum Motor Pump Water Lift Tank Construction Baseplate
More information