1 Item Inquiry Vian code Description QNY Manufacturer disposable O sensor SPXCDXSO1SS senspoint XCD 6 honeywell Sensor Gas,Gasmonitor 0-5 No: Bieler+Lang SENSOR O O-A Senko eip@viansteel.com parts@viansteel.com ext 33-38

2 Exmonitor Gasmonitor Gas Measuring and Alarm Systems

3 Application/Structure The sensors of the series Exmonitor/Gasmonitor used in combination with the analysis systems have the following functions: Measuring and displaying the current concentration of toxic gases and of oxygen. Monitoring and warning signal for: - Excessive concentrations of toxic gases. - Lack of oxygen. Initiating protection measures: - Technical: the increase in concentration is counteracted, or adequate oxygen content/supply is ensured. (ventilator, cut-out functions...). - Organisation: optical and acoustic alarms. A gas alarm unit comprises the following components: Sensor Analysis system Controllable units such as ventilators, warning lights and solenoids. Product features Detection of toxic gases and oxygen Measuring principle: electro-chemical measuring cell Linear measuring signal: 4-0 ma Dual conductor design One-man calibration Easy change of sensor Two construction designs: - Exmonitor for potentially explosive atmospheres with continuous display of gas concentrations - Gasmonitor for non-hazardous areas Exmonitor: ATEX-conformity for applications in hazardous areas zone 1 and Mode of function 3-electrode sensor for toxic gases The eletrodes are surrounded by an electrolyte. The upstream Teflon membrane protects the cell from exposure to dust and moisture. A capillary O Pb Sauerstoffsensor 3-Elektroden-Sensor Potentiostat diffusion barrier ensures that only a limited quantity of test gas reaches the inside of the cell. This also helps to minimize the pressure inflow. The electro-chemical reaction (charge crossover) takes place at the measuring electrode. The potential conditions of the sensor change as a consequence. The potential changes are measured above the reference electrode. The counter electrode is addressed by a potentiostat (controlled diffusuin) such that the potential changes of the cell are compensated. The oxygen required for this process is drawn from the ambient air to the inside of the cell. Dual electrode sensor for oxygen measurements The electrodes are surrounded by an electrolyte. The upstream Teflon membrane protects the cell from exposure to dust and moisture. The diffusing oxygen causes a reaction at the measuring electrode. As a consequence, the potential conditions of the sensor change and the cell suplies a measuring current. Electronics The electronic system includes an amplifier, a 4-0 ma transmitter and operating elements. The sensor signal is amplified and converted into a 4-0 ma signal. The latter is transmitted to the analysis unit, shown as current value in the display, and finally analyzed. Page from 6 Subject to change without notice! 07/010

4 Mode of function Calibrating the mesuring sensor During calibration the sensor delivers a pulsating output signal. The connected analysis unit thus suppresses an alarm output. A malfunction signal is transmitted at the same time. An additional voltage meter is required for the sensor of the type Gasmonitor because this sensor (unlike the Exmonitor) has no display. There are two options for calibrating: - Direct sensor calibration using test gas: Select the operating mode cal gas. Test gas is applied to the sensor and the unit is calibrated with the help of the display (or the connected measuring instrument when using the Gasmonitor) and the potentiometers for zero and amplification. Finally, the sensitivity (calibration number) of the sensor can be read. - Without test gas using a calibrated sensor: Plug in a sensor filled with test gas. Zero is set in air free of test gas. This sensor carries a calibration number. Finally, using the potentiometer for sensitivity, set the display to the calibration number of the sensor. Technical specifications Sensors Measuregas ment Standard measurement range Special measurement range Resolution (standard range) Response ime T t 90 Repeability of signal Type: Exmonitor- Gasmonitor- CO ppm < 30 Sek. 1% CO 1000 H S < 35 Sek. 1% HS 00 H S ppm ppm < 30 Sek. 1% HS 50 SO ppm < 0 Sek. 1% SO 100 SO ppm 0, < 15 Sek. SO 0 NO < 10 Sek. NO 100 NO ppm 0, < 35 Sek. NO 0 Cl ppm 0, < 60 Sek. Cl 0 HCN < 100 Sek. HCN 100 HCl < 10 Sek. HCl 100 H ppm ppm < 30 Sek. H 1000 O vol % 0,1 vol % < 15 Sek. n.c. O 5 NH ppm < 150 Sek. < 10% NH3 50 NH 3 10 ppm < 60 Sek. < 10% NH /010 Subject to change without notice! Page 3 from 6

5 Technical specifications Type Gasmonitor Exmonitor Measuring principle Measuring signal electro-chemical measuring cell ma Supply voltage on the heat terminals Temperature range -10 C C P erm. humidity 15%... 90% rel. F VDC Note to the lost of voltage on the cable, barrier and on the measurinng-shunt in the controller. Pressure range Storage Temperature Pressure coefficient Expected operating life Max. cable length Connecting cable mbar -10 C C <0,0 % of signal / mbar min years (toxic) 15-4 month (oxygen) 1000 m, depending on cable type -core, screened, on cable length conductor cross-section depending Suitable analysis units GMC 80, GMC80E, GMC840, GMC8364 Unit run-up time Cross sensitivity EC-Type- Examination Directive 94/9/EC Recommendet barrier 30 minutes at first start-up 48 hours with type (NH3-50, NO-100, HCl-100) on request II G Ex ia IIC T4 Gb BVS 03 ATEX E 384 Pi: 660 mw Ui: 8 V Ii: 93 ma Li: <= 4 µh Ci: <= 8 nf -10 C <= Ta <= 50 C Current repeater Page 4 from 6 Subject to change without notice! 07/010

6 Mechanical specifications Designation Gasmonitor Exmonitor Protection class IP 54 Enclosure material Aluminum Polyester Weight Dimensions: H x W x D Cable inlet Terminals 400 g 100 g 170 x 64 x 34 mm 115 x 160 x 75 mm cable diameter -pin 0,5... 1,5 mm from 6 mm up to 1 mm Gasmonitor Exmonitor 0 Cal. Ext. Cal. Gas Measure Exmonitor 115 mm 160 mm 07/010 Subject to change without notice! Page 5 from 6

7 Approval EC-Type-Examination Directive 94/9/EC, electrical safty II G Ex ia IIC T4 Gb BVS 03 ATEX E 384 Equipment Service Test gas set Calibration gases barriers Everything from one source - from project development to the installation of your new gas alarm unit. Guaranteed by our comprehensive sales and service network. Call us for the address of your local contact partner. Our after-sales technicians are pleased to assist you with hands-on help and advice. Bieler + Lang GmbH Gasmess- und Warnsysteme Postfach 119, D-7784 Achern Von-Drais-Straße 31, D Achern Telephone +49 (0) / Telefax +49 (0) / info@bieler-lang.de Internet Page 6 from 6 Subject to change without notice! 07/010

8 ec ec ec hnical hnical hnical Specif Specif Specif ica ica ica tion tion tion tion O-A Oxygen Sensor Figure 1 O-A Schematic Diagram Tec echnical hnical Specifica Specif ication All dimensions in millimetres (± 0.1mm) Top View Bottom View Side View PERFORMANCE Output 0.9% O 80 to 10 Response time t90 (s) from 0.9% to 0% O < 15 Zero current µa in N < Pressure sensitivity (% change of output)/(% change of 0kPa < 0.1 Linearity % O 10% O 0.6 Hysteresis % O change after 16 cycles: 0 to 0.9% O < 0.15 Hand aspirator % O change during aspiration (typical) 19.5 to.5 response LIFETIME Output drift % change in 3 months < 1 Operating life months until 85% original output of 0.9% O > 4 ENVIRONMENTAL Humidity Sensitivity % O change: 0% to 95% 40 C < 0.7 CO sensitivity % (change O reading) / % 5% CO 0.1 PHYSICAL Diameter mm (including label) 0.0 DIMENSIONS Height mm (including foam ring) 16.8 Weight g < 16 KEY Temperature range C -30 to 55 SPECIFICATIONS Pressure range kpa 80 to 10 Humidity range % rh continuous (0 to 99% rh short term) 5 to 95 Storage period 3 to 0 C (store in sealed pot, open circuit) 6 Load resistor Ω (recommended) 47 to 100 NOTE: all sensors are tested at ambient environmental conditions, with 47 ohm load resistor, unless otherwise stated. As applications of use are outside our control, the information provided is given without legal responsibility. Customers should test under their own conditions, to ensure that the sensors are suitable for their own requirements. Alphasense Ltd, Sensor Technology House, 300 Avenue West, Skyline 10, Great Notley. CM77 7AA. UK Telephone: +44 (0) Fax: +44 (0) sensors@alphasense.com Website:

9 ec ec ec hnical hnical hnical Specif Specif Specif Output (ua) ica ica ica tion tion tion tion O-A Perf erformance Data Tec echnical hnical Specifica Specif ication Figure Output Temperature Dependence % output (relative to output at 0 o C) Temperature ( o C) Figure 3 Sensitivity at 50 o C % (sensitivity at 50 o C) / (sensitivity at 0 o C) Nominal Batch Number Figure 4 Long Term Stability Days Figure shows the variation in sensitivity caused by changes in temperature. This plot of the mean and ± 95% confidence intervals for 34 batches shows superior repeatability of the sensitivity dependence from batch to batch, giving confidence when setting temperature compensation in your gas detector. The very stable output over the full lifetime of the O-A shows that Alphasense has solved the problem of poor performance near the end of lifetime. For further information on the performance of this sensor, on other sensors in the range or any other subject, please contact Alphasense Ltd. For Application Notes visit In the interest of continued product improvement, we reserve the right to change design features and specifications without prior notification. The data contained in this document is for guidance only. Alphasense Ltd accepts no liability for any consequential losses, injury or damage resulting from the use of this document or the information contained within it. ( ALPHASENSE LTD ) Doc. Ref. TDS/OA/Issue 13

ExDetector HC-100. Data Sheet. Gas Measuring and Alarm Systems

ExDetector HC-100. Data Sheet. Gas Measuring and Alarm Systems HC-100 Gas Measuring and Alarm Systems HC-100 Application / Construction The HC100 series of measuring probes, used in conjunction with evaluation systems, have the following functions: Measurement and

More information

ExDetector IRCO2. ExDetector IRHC. Operating and Installation Instructions. Gas Detection and Warning Systems

ExDetector IRCO2. ExDetector IRHC. Operating and Installation Instructions. Gas Detection and Warning Systems IRCO2 IRHC Operating and Installation Instructions Gas Detection and Warning Systems Important Instructions Prerequisites for safe and reliable operation of the system: Appropriate transport and handling

More information

EC24. Operation Manual. (Type MWG 2411, MWG 2412, MWG 2413 and MWG 2414)

EC24. Operation Manual. (Type MWG 2411, MWG 2412, MWG 2413 and MWG 2414) Operation Manual EC24 (Type MWG 2411, MWG 2412, MWG 2413 and MWG 2414) GfG GESELLSCHAFT FÜR GERÄTEBAU MBH KLÖNNESTRASSE 99 D-44143 DORTMUND TELEPHONE +49/(0)231 / 564 00 0 FAX +49/(0)231 / 516313 INFO@GFG-MBH.COM

More information

GAS DETECTOR ST400EC PART.NO

GAS DETECTOR ST400EC PART.NO DATA SHEET 1(7) GAS DETECTOR ST400EC PART.NO. 004461-004467 DETECTION OF TOXIC GASES AND OXYGEN SYSTEM GS5000, GS3000, SW2020, BUCONTROL / BUTOUCH GENERAL DESCRIPTION Detection of toxic gases and Oxygen

More information

IR25 Dual Gas Series Datasheet

IR25 Dual Gas Series Datasheet SGX Europe Sp. z o.o. IR25 Dual Gas Series Datasheet Infrared Dual Gas Sensor for Mining (Portable and Fixed Systems) The SGX infrared sensors use the proven Non-Dispersive Infrared (NDIR) principle to

More information

CMF, CMX & CMA series

CMF, CMX & CMA series Features Electrochemical sensor element 4-20 ma or 2-10 Vdc output CMF- IP 44 protection CMX- IP 54 protection CMA- IP 65 protection Wide supply voltage range (18-28 Vdc) Overload and short cicuit protected

More information

Fixed Gas Detection System/Meridian CERTIFICATION

Fixed Gas Detection System/Meridian CERTIFICATION The marking shall include 2 Wire Aluminum Transmitter 3/4 Wire Aluminum Transmitter 2 Wire Stainless Steel Transmitter (PN: 096-3521) (PN: 096-3522) (PN: 096-3525) Ex db [ia Ga] IIC T4 Gb Ex db [ia Ga]

More information

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors Dräger Polytron 5700 Fixed Gas Detector Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors Dräger Polytron 5700 Including e-box for increased safety wiring The Dräger

More information

Gas cylinder scale Model GCS-1

Gas cylinder scale Model GCS-1 Electronic pressure measurement Gas cylinder scale Model GCS-1 WIKA data sheet PE 87.19 Applications Level measurement of liquid gases in gas cabinets and gas distribution systems Level measurement in

More information

Stand Alone DYNAGARD SP Operation Manual

Stand Alone DYNAGARD SP Operation Manual Stand Alone DYNAGARD SP Operation Manual Contents Page General Description 1 Detection Principle 1 For Your Safety 1 Design 2 Mounting 2 Mounting Position of DYNAGARD SP 2 Installation of Electrical Connections

More information

User Manual. PolyGard CO LC-1112 V3. Electrochemical analog carbon monoxide transmitters serial no. EC-S 002. August 29, 2006

User Manual. PolyGard CO LC-1112 V3. Electrochemical analog carbon monoxide transmitters serial no. EC-S 002. August 29, 2006 PolyGard CO LC-1112 V3 Electrochemical analog carbon monoxide transmitters serial no. EC-S 002 User Manual August 29, 2006 January 04, 2016 Revision Specifications subject to change without notice. USA

More information

MICROpeL 75 Combustible Gas Sensor Part Number: PM

MICROpeL 75 Combustible Gas Sensor Part Number: PM MICROpeL 75 Combustible Gas Sensor Part Number: PM759-000 Key Features & Benefits: ATEX, UL and CSA Approvals Withstands EN/IEC 60079-0 impact test Enhanced H 2 S and silicone poison resistance Reduced

More information

Models TX-KE and TX-KP Toxic Gas Transmitters

Models TX-KE and TX-KP Toxic Gas Transmitters Models TX-KE and TX-KP Toxic Gas Transmitters Instruction Manual PureAire Monitoring Systems, Inc. 557 Capital Dr. Lake Zurich, IL. 60047 Phone: 847-726-6000 Fax: 847-726-6051 Toll-Free: 888-788-8050 www.pureairemonitoring.com

More information

Micro III (Models G203, G203S, and G213) Operation Manual

Micro III (Models G203, G203S, and G213) Operation Manual Micro III (Models G03, G03S, and G13) Operation Manual Worldwide Manufacturer of Gas Detection Solutions Table of contents Page Introduction... 3 For your safety... 3 Application and use... 3 General

More information

IR1xxx Series 1, IR2xxx Series 1 Miniature Infrared Gas Sensors for Hazardous Areas and Intrinsic Safety in Mining

IR1xxx Series 1, IR2xxx Series 1 Miniature Infrared Gas Sensors for Hazardous Areas and Intrinsic Safety in Mining IR1xxx Series 1, IR2xxx Series 1 Miniature Infrared Gas Sensors for Hazardous Areas and Intrinsic Safety in Mining FEATURES * Configured for carbon dioxide (IR11BD, IR21BD), hydrocarbons (,,, ) or acetylene

More information

IR15 Dual Gas Series Datasheet

IR15 Dual Gas Series Datasheet SGX Europe Sp. z o.o. IR15 Dual Gas Series Datasheet Infrared Dual Gas Sensor for Hazardous Environments (Portable and Fixed Systems) The SGX infrared sensors use the proven Non-Dispersive Infrared (NDIR)

More information

MICRO III (G202 / G202s / G212) Single Gas Detector

MICRO III (G202 / G202s / G212) Single Gas Detector Operation Manual MICRO III (G202 / G202s / G212) Single Gas Detector GfG GESELLSCHAFT FÜR GERÄTEBAU MBH KLÖNNESTRASSE 99 D-44143 DORTMUND TELEPHONE +49 / (0) 2 31 / 5 64 00 0 FAX +49 / (0) 2 31 / 51 63

More information

IR1 Single Gas Series Datasheet

IR1 Single Gas Series Datasheet SGX Europe Sp. z o.o. IR1 Single Gas Series Datasheet Infrared Single Gas Sensor for Hazardous Environments (Portable and Fixed Systems) The SGX infrared sensors use the proven Non-Dispersive Infrared

More information

Operating Instructions Compur Monitox plus

Operating Instructions Compur Monitox plus Operating Instructions Compur Monitox plus Subject to changes without notice. Copyright Compur Monitors München Editor: Compur Monitors GmbH & Co. KG Weissenseestr. 101 D-81539 München Content Page Monitox

More information

Dräger X-am 5600 Personal Monitor Multi-Gas Detection Device

Dräger X-am 5600 Personal Monitor Multi-Gas Detection Device Dräger X-am 5600 Personal Monitor Multi-Gas Detection Device Featuring an ergonomic design and innovative infrared sensor technology, the Dräger X-am 5600 is the smallest gas detection instrument for the

More information

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications Force Pressure Temperature Switch Pressure sensors Ex ia I / IIC T6 acc. to ATEX with internal diaphragm with front flush diaphragm Accuracy: 0,25% and 0,5 % Standard output: 4...20 ma; 2-wire system Description

More information

Safe Operation Manual. Honeywell IQ Force Gas Detector

Safe Operation Manual. Honeywell IQ Force Gas Detector Safe Operation Manual Honeywell IQ Force Gas Detector Honeywell Analytics 800-663-4164 403-248-9226 Fax 403-575-3708 03JUN2012 P/N 50105843-047 Version 01 http://www.honeywell.com HONEYWELL IQ Force PERSONAL

More information

Lamp Supply (Recommended)

Lamp Supply (Recommended) SGX Europe Sp. z o.o. IR600 Datasheet Infrared Gas Sensor for Hazardous Areas (Fixed Systems) The IR600 Series gas sensors are designed to detect and monitor the presence of CO 2, hydrocarbons and acetylene

More information

IR15TT-R Miniature Infrared Gas Sensor for Monitoring Carbon Dioxide and Methane up to 100% Vol.

IR15TT-R Miniature Infrared Gas Sensor for Monitoring Carbon Dioxide and Methane up to 100% Vol. IR15TT-R Miniature Infrared Gas Sensor for Monitoring Carbon Dioxide and Methane up to 100% Vol. FEATURES Two active gas channels for simultaneous detection of carbon dioxide and methane (or other hydrocarbons)

More information

Transmitters/Sensors. OLCT Series

Transmitters/Sensors. OLCT Series Transmitters/Sensors Gas Monitoring Solutions OLCT 20-40-50-60 Series SIL2 based on EN 50402 (OLCT 60 based on EN 50271) FLP approved Intrinsically Safe (IS) Precalibrated block module local or remote

More information

IRceL CH4 Methane (CH 4

IRceL CH4 Methane (CH 4 Product Datasheet IRceL CH4 Methane Sensor Document Purpose The purpose of this document is to present the performance specification of the IRceL CH4 Methane gas sensor. This document should be used in

More information

SITRANS T. SITRANS T Explosion protected temperature sensor. General information. Marking of the degree of protection. Range of uses.

SITRANS T. SITRANS T Explosion protected temperature sensor. General information. Marking of the degree of protection. Range of uses. General information 1 Marking of the degree of protection 2 SITRANS T SITRANS T Explosion protected temperature sensor Operating Instructions Range of uses 3 Installation 4 Assembly and disassembly 5 Commissioning

More information

ALTAIR 5X Multigas Detector Product Specification

ALTAIR 5X Multigas Detector Product Specification ALTAIR 5X Multigas Detector Product Specification PHYSICAL CHARACTERISTICS Gas delivery Size, pumped unit without IR Size, pumped unit with IR Weight Handling Case material Environmental protection Display

More information

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head 4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head NET DRAFT version 2.1-2008 Pag. 1 4-20mA Cyber - DRAFT version 2.1-2008 Pag.

More information

Gas Detection - GD -

Gas Detection - GD - s Gas Detection TECHNICAL SPECIFICATIONS Gas Detection DATA SHEE - GD - Continuing development sometimes necessitates specification changes without notice Technical Specifications 2008 GD-00 Gas Measuring

More information

VQ500 Series Combustible Gas Detector Elements

VQ500 Series Combustible Gas Detector Elements VQ500 Series Combustible Gas Detector Elements FEATURES * Optimised for combustible gases and vapours * Thermal conductivity versions available * Certified flameproof component * Integral pellistors *

More information

Detectors-Transmitters for Flammable, Toxic Gases and Oxygen. Non-intrusive operation via intrinsically safe infrared remote control.

Detectors-Transmitters for Flammable, Toxic Gases and Oxygen. Non-intrusive operation via intrinsically safe infrared remote control. Détecteur de gaz OLCT80 Detectors-Transmitters for Flammable, Toxic Gases and Oxygen Non-intrusive operation via intrinsically safe infrared remote control Disponible en version déportée, ADF ou de SI

More information

Alphasense Application Note AAN 106 HUMIDITY EXTREMES: DRYING OUT AND WATER ABSORPTION

Alphasense Application Note AAN 106 HUMIDITY EXTREMES: DRYING OUT AND WATER ABSORPTION AAN 106 HUMIDITY EXTREMES: DRYING OUT AND WATER ABSORPTION Alphasense electrochemical toxic gas sensors are low power devices with excellent resolution, dynamic range and selectivity. These electrochemical

More information

FREEDOM SERIES 5000 AND 5600 GAS TRANSMITTERS

FREEDOM SERIES 5000 AND 5600 GAS TRANSMITTERS FREEDOM SERIES 5000 AND 5600 GAS TRANSMITTERS FREEDOM SERIES 5000 & 5600 MAKING INSTALLATION AND EVERYDAY OPERATION EASY The Freedom Series 5000 and 5600 are full-featured 4-20mA, loop powered transmitters

More information

4P-90 CiTipeL Combustible Gas Sensor Part Number: PM

4P-90 CiTipeL Combustible Gas Sensor Part Number: PM Key Features & Benefits: ATEX, UL and CSA Approvals Withstands EN/IEC 60079-0 impact test Enhanced H 2 S and silicone poison resistance 4P-90 CiTipeL Combustible Gas Sensor Part Number: PM143-000 Performance

More information

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor Labkotec UK Ltd Adminicle House 1 Lumb Lane Audenshaw Manchester M34 5WH GREAT BRITAIN Tel: 0844 3350 477 Fax: 0161 4281 179 E-mail: info@labkotec.co.uk 10.8.2012 Internet: www.labkotec.co.uk 1/13 OilSET-1000

More information

CARBON MONOXIDE CO SS SOLID STATE ELECTROCHEMICAL SENSORS

CARBON MONOXIDE CO SS SOLID STATE ELECTROCHEMICAL SENSORS 1. DESCRIPTION OF TECHNOLOGY The CO sensor is based on the technology of electrochemical gas detection principle. This technology can be used to detect chemicals or gases that can be oxidized or reduced

More information

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Certifications. The Fixed Gas Detection People

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Certifications. The Fixed Gas Detection People Fixed Gas Detector Detection of explosive gases, toxic gases or oxygen Infrared XP version SIL 2 high reliability IP 66 Certifications The Fixed Gas Detection People The OLC/OLCT CT range of fixed ddetectors

More information

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots 5 Operating Modes GX-6000 Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots GX-6000 5 Operating modes Normal Leak Check Inert Bar hole Snap Log Monitor up to

More information

Transmitter for O 2 ZD21. Operation Manual

Transmitter for O 2 ZD21. Operation Manual Transmitter for O 2 ZD21 Operation Manual Table of contents Page For your Safety...4 General Description...4 Detection Principle...5 Operational Notes...5 Design...5 Mounting Position...6 Mounting...7

More information

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots 5 Operating Modes GX-6000 Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots CONFINED SPACE ENTRY Monitor LEL, O2, CO, and H2S Internal sample pump Pull samples

More information

Dräger Polytron 8000 Stationary gas detector (EC)

Dräger Polytron 8000 Stationary gas detector (EC) Dräger Polytron 8000 Stationary gas detector (EC) The microprocessor-based transmitter can be equipped with various electrochemical DrägerSensors. This way, you can easily detect oxygen and various toxic

More information

4P75 CiTipeL Combustible Gas Sensor Part Number: PM

4P75 CiTipeL Combustible Gas Sensor Part Number: PM Product Datasheet 4P75 Document Purpose The purpose of this document is to present the performance specification of the 4P75 CiTipeL. This document should be used in conjunction with Operating Principles

More information

Electrochemical (EC) DrägerSensors for Fixed Gas Detectors

Electrochemical (EC) DrägerSensors for Fixed Gas Detectors Electrochemical (EC) DrägerSensors for Fixed Gas Detectors When you need to selectively measure the smallest concentrations of airborne toxic gases and oxygen under ambient conditions, Electrochemical

More information

EU DECLARATION OF CONFORMITY

EU DECLARATION OF CONFORMITY The Low Voltage Directive (LVD) 2014/35/EU and Electromagnetic Compatibility (EMC) Directive 2014/30/EU. Capacitive level sensor DLS 27N(T) Capacitive level sensor type DLS 27N(T) is designed to bistable

More information

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required Sieger Sensepoint The Sensepoint range of flammable, toxic and oxygen gas detectors offer users a high quality, low cost solution to their industrial gas monitoring needs. Sieger Sensepoint Fit For Purpose

More information

Datasheet: K-22 LO Sensor

Datasheet: K-22 LO Sensor Datasheet: K-22 LO Sensor The K- 22 LO is a CO2 sensor module designed to be built- in into stationary ventilation equipment, such as window vent or duct exhaust actuators, serving as a linear transmitter

More information

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Dräger Polytron 5700 IR Detection of flammable gases and vapours Dräger Polytron 5700 IR Detection of flammable gases and vapours The Dräger Polytron 5700 IR is a cost effective explosion-proof transmitter for the detection of flammable gases in the lower explosive

More information

Differential Pressure and Flow Meter Media 5 Indicator 160 PN 40

Differential Pressure and Flow Meter Media 5 Indicator 160 PN 40 Differential Pressure and Flow Meter Media 5 Indicator 160 PN 40 Application Instrument designed to measure and indicate differential pressure or measured variables derived from it For gases or liquids

More information

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Aluminium or Stainless Steel version

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Aluminium or Stainless Steel version Fixed Gas Detector Detection of explosive gases, toxic gases or oxygen Infrared XP version SIL 2 high reliability IP 66 Aluminium or Stainless Steel version Certifications Pending The Fixed Gas Detection

More information

testo 316-EX gas leak detector Instruction manual

testo 316-EX gas leak detector Instruction manual testo 316-EX gas leak detector Instruction manual 2 1 Safety and the environment 1 Safety and the environment 1.1. About this document Use > Please read this documentation through carefully and familiarize

More information

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Dräger Polytron 8700 IR Detection of flammable gases and vapors Dräger Polytron 8700 IR Detection of flammable gases and vapors The Dräger Polytron 8700 IR is an advanced explosion proof transmitter for the detection of combustible gases in the lower explosion limit

More information

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20 Electronic Pressure Measurement Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20 Applications Chemical, Petrochemical

More information

BA334D Intrinsically safe Externally powered pulse input field mounting rate totaliser Issue 13

BA334D Intrinsically safe Externally powered pulse input field mounting rate totaliser Issue 13 TR Automatyka Sp. z o. o. Tel. (+48 022) 886 10 16 www.trautomatyka.pl ul. Lechicka 14 ; 02-156 Warszawa Fax. (+48 022) 846 50 37 biuro@trautomatyka.pl BA334D Intrinsically safe Externally powered pulse

More information

Dräger X-am 5000 Multi-Gas Detection

Dräger X-am 5000 Multi-Gas Detection Dräger X-am 5000 Multi-Gas Detection The Dräger X-am 5000 belongs to a generation of gas detectors, developed especially for personal monitoring applications. This 1- to 5-gas detector reliably measures

More information

Technical Data. General specifications. Rated operating distance s n 5 mm

Technical Data. General specifications. Rated operating distance s n 5 mm 0102 Model Number Features 5 mm non-flush Usable up to SIL 2 acc. to IEC 61508 Technical Data specifications Switching function Normally closed (NC) Output type NAMUR Rated operating distance s n 5 mm

More information

BA338C Intrinsically safe Externally powered pulse input panel mounting rate totaliser issue 13

BA338C Intrinsically safe Externally powered pulse input panel mounting rate totaliser issue 13 BA338C Intrinsically safe Externally powered pulse input panel mounting rate totaliser issue 13 Certification information label Total display Rate display Rotating flow indicator Annunciators for optional

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features 8 mm non-flush Stainless steel housing Usable up to SIL2 acc. to IEC 61508 Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 8 mm

More information

RK Hydrogen Sulfide Transmitter Operator s Manual

RK Hydrogen Sulfide Transmitter Operator s Manual 65-2331RK Hydrogen Sulfide Transmitter Operator s Manual Part Number: 71-0176RK Revision: B Released: 11/26/14 RKI Instruments, Inc. www.rkiinstruments.com WARNING Read and understand this instruction

More information

Inductive slot sensor

Inductive slot sensor 0102 Model Number Features 2 mm slot width Technical Data specifications Switching function Normally closed (NC) Output type NAMUR Slot width 2 mm Depth of immersion (lateral) 5... 7 mm, typ. 6 mm Output

More information

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm 0102 Model Number Features 5 mm non-flush Usable up to SIL2 acc. to IEC 61508 Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 5 mm Installation non-flush

More information

Documentation. Explosion-Protection. for Smoke Detection Panels SDS-4, SDS-8, SDS-12 and Extension Panels SDS-E8, SDS-E12, SDS-E16, SDS-EC16

Documentation. Explosion-Protection. for Smoke Detection Panels SDS-4, SDS-8, SDS-12 and Extension Panels SDS-E8, SDS-E12, SDS-E16, SDS-EC16 safetec Documentation Explosion-Protection for Smoke Detection Panels SDS-4, SDS-8, SDS-12 and Extension Panels SDS-E8, SDS-E12, SDS-E16, SDS-EC16 in Smoke Detection System SDS-48 according IEC 60079-25

More information

Model 144H. Product Data Sheet , Rev DB February Content

Model 144H. Product Data Sheet , Rev DB February Content Rosemount 144 PC-Programmable Temperature Transmitter Provides an installation-ready solution for temperature monitoring applications using Complete Point Solutions (CPS) Increases measurement accuracy

More information

Electrochemical DrägerSensor Sensors for Fixed Gas Detectors

Electrochemical DrägerSensor Sensors for Fixed Gas Detectors Electrochemical DrägerSensor Sensors for Fixed Gas Detectors Fast response, high accuracy, great stability, long life. Electrochemical DrägerSensors offer all these benefits. You can use the robust and

More information

Dräger X-am 5000 Multi-Gas Detection

Dräger X-am 5000 Multi-Gas Detection Dräger X-am 5000 Multi-Gas Detection The Dräger X-am 5000 belongs to a generation of gas detectors, developed especially for personal monitoring applications. This 1- to 5-gas detector reliably measures

More information

OLC(T) 100 FIXED GAS DETECTOR

OLC(T) 100 FIXED GAS DETECTOR Fixed Gas Detector OLC(T) FIXED GAS DETECTOR Detection of explosive gases, toxic gases or oxygen Infrared XP version SIL 2 high reliability IP 66 Aluminium or Stainless Steel version CERTIFICATIONS The

More information

Model 144H. Product Data Sheet , Rev DB February Content

Model 144H. Product Data Sheet , Rev DB February Content Rosemount 144 PC-Programmable Temperature Transmitter Provides an installation-ready solution for temperature monitoring applications using Complete Point Solutions (CPS) Increases measurement accuracy

More information

Druck DPI 705/DPI 705 IS Series

Druck DPI 705/DPI 705 IS Series GE Sensing & Inspection Technologies 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Druck DPI 705/DPI 705 IS Series Digital Pressure

More information

Annubar Flowmeter Series

Annubar Flowmeter Series Reference Manual Appendix B Approvals Annubar Flowmeter Series Hazardous Locations Installations.................. page B-1 Rosemount 3051SFA Product Certifications.......... page B-1 Rosemount 3095MFA

More information

Micro IV Operation Manual

Micro IV Operation Manual Micro IV Operation Manual Worldwide Manufacturer of Gas Detection Solutions TABLE OF CONTENTS Page Introduction...4 For Your Safety...4 Application and Use...4 General Description...4 Detection Principle...5

More information

Dräger Polytron 5720 IR Toxic Gas Detection

Dräger Polytron 5720 IR Toxic Gas Detection Dräger Polytron 5720 IR Toxic Gas Detection The Dräger Polytron 5720 IR is a cost-effective explosion proof transmitter for the detection of carbon dioxide in volume percentage or ppm It uses a high-performance

More information

Dräger Polytron (approved as type P3S) Transmitter for electrochemical Sensors. Instructions for Use. ST eps

Dräger Polytron (approved as type P3S) Transmitter for electrochemical Sensors. Instructions for Use. ST eps D Dräger Polytron 3000 (approved as type P3S) Transmitter for electrochemical Sensors Instructions for Use ST 691 2002.eps Contents Contents For Your Safety............................................................

More information

P R O D U C T D ATA S H E E T

P R O D U C T D ATA S H E E T TOCSIN 750 SERIES ANNUNCIATORS Addressable Gas Detection Interface Point -Wire Addressable Systems Sounder Display Shows: Reading-Message-Alarm RGB Relay Output off Solid State Beacon Sounder Output off

More information

GMS-10 RVS Series. Oxygen Sensors Accurate oxygen measurement WARNING WARNING DESCRIPTION TYPICAL APPLICATIONS FEATURES MISUSE OF DOCUMENTATION

GMS-10 RVS Series. Oxygen Sensors Accurate oxygen measurement WARNING WARNING DESCRIPTION TYPICAL APPLICATIONS FEATURES MISUSE OF DOCUMENTATION GMS-10 RVS Series Oxygen Sensors Accurate oxygen measurement DESCRIPTION The GMS-10 is a high-accuracy oxygen sensor suitable for many applications. Originally developed for boiler applications, the product

More information

Differential Pressure and Flow Meter. Media 5 Indicator 160 Ø PN 50

Differential Pressure and Flow Meter. Media 5 Indicator 160 Ø PN 50 Differential Pressure and Flow Meter Media 5 Indicator 160 Ø PN 50 Application Transmitter for measuring and indicating the differential pressure or measured variables derived from it Suitable for gases

More information

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Dräger Polytron 5200 CAT Detection of flammable gases and vapours Dräger Polytron 5200 CAT Detection of flammable gases and vapours The Dräger Polytron 5200 CAT is a cost-effective explosion-proof transmitter for the detection of flammable gases in the lower explosion

More information

4) Intrinsic Safety Certification

4) Intrinsic Safety Certification INSTRUCTION MANUAL Minialert Intrinsically Safe Round Combined Unit Section Volume Control Tone Generator S2 S3 Tone Selection Switches Fig 1 Simplified block diagram The combined unit is CE marked for

More information

3M Oldham OLCT 100. Description. Fixed Gas Detector

3M Oldham OLCT 100. Description. Fixed Gas Detector Fixed Gas Detector Description The OLC/OLCT range of fixed detectors has been designed for detection of combustible gases, toxic gases or oxygen. Available in explosion-proof or intrinsically safe versions,

More information

Sieger Apex. Flexibility that meets your requirements

Sieger Apex. Flexibility that meets your requirements Sieger Apex Flexibility that meets your requirements Sieger Apex Easy to Install Sensor can be remotely mounted up to 100m from the transmitter On board relays allow for local audible/ visual alarms Strong

More information

Sensepoint. Fit For Purpose Flammable, toxic and Oxygen versions available High performance, low cost Suitable for new and retro fit applications

Sensepoint. Fit For Purpose Flammable, toxic and Oxygen versions available High performance, low cost Suitable for new and retro fit applications Sensepoint The Sensepoint range of flammable, toxic and Oxygen gas detectors offer users a high quality, low cost solution to their industrial gas monitoring needs. Sensepoint Fit For Purpose Flammable,

More information

Dräger Polytron SE Ex Fixed Gas Detector

Dräger Polytron SE Ex Fixed Gas Detector Dräger Polytron SE Ex Fixed Gas Detector The Dräger Polytron SE Ex... DD sensing heads are gas detectors for the continuous monitoring of flammable gases and vapors in the ambient air. The measurement

More information

ATEX GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres. Directive 94/9/EC

ATEX GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres. Directive 94/9/EC Quick Introduction to TÛV Denmark TÜV Denmark - is a part of the TÜV NORD Group a global Organisation f Certification and Inspection of: Quality Management Systems, Products, Processes and Qualification

More information

ALTAIR 5X Multigas Detector

ALTAIR 5X Multigas Detector ALTAIR 5X Multigas Detector With MSA XCell Sensor Technology IT S WHAT S INSIDE THAT COUNTS Now with advanced PID for VOC Detection Because every life has a purpose IT S WHAT S INSIDE THAT COUNTS WORKERS

More information

PEPPERL+FUCHS GmbH

PEPPERL+FUCHS GmbH Comfort series 1.5 mm embeddable M8x1 4 25 16 13 LED Switching element function NAMUR NC Rated operating distance s n 1,5 mm Installation embeddable Assured operating distance s a 0... 1,215 mm Reduction

More information

RK Carbon Monoxide Transmitter Operator s Manual

RK Carbon Monoxide Transmitter Operator s Manual 65-2434RK Carbon Monoxide Transmitter Operator s Manual Part Number: 71-0061RK Edition: First, Revision C Released: December 2001 65-2434RK CO Transmitter 1 Product Warranty RKI Instruments, Inc., warranties

More information

User Manual. GPD 3000 e. gas detector

User Manual. GPD 3000 e. gas detector User Manual GPD 3000 e gas detector Table of contents Application...3 Unit ppm, Vol.%...4 Operation elements GDP 3000 e...5 Gas sensor...6 Important Information off sensor!...6 Measurement range...7 Turning

More information

FAHM Co. Temperature Transmitter PTT74 Series

FAHM Co. Temperature Transmitter PTT74 Series FAHM Co. PTT74 Series The PTT74 is a versatile temperature transmitter that delivers field reliability and advanced accuracy and stability to meet demanding process needs. PTT74 Family of Transmitters

More information

Dräger X-am 7000 Multi-Gas Detection

Dräger X-am 7000 Multi-Gas Detection Dräger X-am 7000 Multi-Gas Detection Dräger X-am 7000 is the solution for the simultaneous and continuous measurement of up to five gases. It is the ideal companion in a variety of applications where the

More information

REGARD. REGARD 4-20 AND Ex CHANNEL CARDS INSTALLATION AND OPERATING MANUAL (FOR ATEX VERSION CARDS)

REGARD. REGARD 4-20 AND Ex CHANNEL CARDS INSTALLATION AND OPERATING MANUAL (FOR ATEX VERSION CARDS) REGARD REGARD 4-20 AND Ex CHANNEL CARDS INSTALLATION AND OPERATING MANUAL (FOR ATEX VERSION CARDS) Part No. 4206712 For use with Regard 4-20 and Ex cards software version 3.0 or later. Draeger Safety UK

More information

SIMRAD GD10PE IR GAS DETECTOR

SIMRAD GD10PE IR GAS DETECTOR SIMRAD GD10PE IR GAS DETECTOR Operating Manual P3404E 1st edition Jan. 2004 www.simrad-optronics.com CONTENTS 1. PRODUCT DESCRIPTION... 5 1.1 General description... 5 1.2 Construction... 5 1.3 Application

More information

MICRO IV. Operation Manual. Single Gas Detector

MICRO IV. Operation Manual. Single Gas Detector Operation Manual MICRO IV Single Gas Detector GfG GESELLSCHAFT FÜR GERÄTEBAU MBH KLÖNNESTRASSE 99 D-44143 DORTMUND TELEPHONE +49 / (0) 2 31 / 5 64 00 0 FAX +49 / (0) 2 31 / 51 63 13 INFO@GFG-MBH.COM WWW.GASDETECTION.BIZ

More information

Dräger Polytron 8720 IR Detection of carbon dioxide

Dräger Polytron 8720 IR Detection of carbon dioxide Dräger Polytron 8720 IR Detection of carbon dioxide The Dräger Polytron 8720 IR is an advanced explosion proof transmitter for the detection of carbon dioxide in percent volume or ppm It uses a high performance

More information

CT-7 Series Toxic Gas Transmitter Operator s Manual

CT-7 Series Toxic Gas Transmitter Operator s Manual 65-2341 CT-7 Series Toxic Gas Transmitter Operator s Manual Part Number: 71-0424 Revision: P1 Released: 6/8/17 RKI Instruments, Inc. www.rkiinstruments.com WARNING Read and understand this instruction

More information

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Dräger Polytron 8700 IR Detection of flammable gases and vapors Dräger Polytron 8700 IR Detection of flammable gases and vapors The Dräger Polytron 8700 IR is an advanced explosion proof transmitter for the detection of combustible gases in the lower explosion limit

More information

L+T GASETECHNIK. Klöpper-Waldmann GmbH & Co. K G. Alarm unit LSG4

L+T GASETECHNIK. Klöpper-Waldmann GmbH & Co. K G. Alarm unit LSG4 Areas of application The LSG4 alarm unit is used for monitoring industrial systems, e.g. in the following areas: Alarm and hazard stati in production e.g. for monitoring temperature and pressure in reactors

More information

Dräger X-am 2500 Multi-Gas Detection

Dräger X-am 2500 Multi-Gas Detection Dräger X-am 2500 Multi-Gas Detection The Dräger X-am 2500 was especially developed for use as personal protection. The 1 to 4 gas detector reliably detects combustible gases and vapours, as well as O2,

More information

Dräger X-zone 5500 Area Monitoring

Dräger X-zone 5500 Area Monitoring Dräger X-zone 5500 Area Monitoring Dräger's X-zone 5500 brings a safer, more effective way to monitor hazardous gases--reinventing area monitoring. In combination with the Dräger X-am 5000, 5100, or 5600

More information

OLCT 10N. Digital Gas Detector. User Manual. The Fixed Gas Detection Experts. Part Number: NPO10NEN Version: G.1

OLCT 10N. Digital Gas Detector. User Manual. The Fixed Gas Detection Experts. Part Number: NPO10NEN Version: G.1 User Manual OLCT 10N Digital Gas Detector Part Number: NPO10NEN Version: G.1 The Fixed Gas Detection Experts Copyright 2015 by OLDHAM S.A.S May 2015 All rights reserved. No reproduction of all or part

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features 5 mm flush Usable up to SIL2 acc. to IEC 61508 Accessories EXG-18 Quick mounting bracket with dead stop BF 18 Mounting flange, 18 mm Technical Data specifications Switching element

More information

SENSE Instruments CO., LTD. Data sheet Gas detector Page 1 / 5. Gas detector

SENSE Instruments CO., LTD. Data sheet Gas detector Page 1 / 5. Gas detector Page 1 / 5 Gas detector Brief SEN series smart gas transmitter changes the gas concentration into standard 4~20mA current source signal, Online free parking digital free configuration,multi-parameter backlight

More information