SENSOR O2 O2-A
|
|
- Matthew Lee
- 5 years ago
- Views:
Transcription
1 Item Inquiry Vian code Description QNY Manufacturer disposable O sensor SPXCDXSO1SS senspoint XCD 6 honeywell Sensor Gas,Gasmonitor 0-5 No: Bieler+Lang SENSOR O O-A Senko eip@viansteel.com parts@viansteel.com ext 33-38
2 Exmonitor Gasmonitor Gas Measuring and Alarm Systems
3 Application/Structure The sensors of the series Exmonitor/Gasmonitor used in combination with the analysis systems have the following functions: Measuring and displaying the current concentration of toxic gases and of oxygen. Monitoring and warning signal for: - Excessive concentrations of toxic gases. - Lack of oxygen. Initiating protection measures: - Technical: the increase in concentration is counteracted, or adequate oxygen content/supply is ensured. (ventilator, cut-out functions...). - Organisation: optical and acoustic alarms. A gas alarm unit comprises the following components: Sensor Analysis system Controllable units such as ventilators, warning lights and solenoids. Product features Detection of toxic gases and oxygen Measuring principle: electro-chemical measuring cell Linear measuring signal: 4-0 ma Dual conductor design One-man calibration Easy change of sensor Two construction designs: - Exmonitor for potentially explosive atmospheres with continuous display of gas concentrations - Gasmonitor for non-hazardous areas Exmonitor: ATEX-conformity for applications in hazardous areas zone 1 and Mode of function 3-electrode sensor for toxic gases The eletrodes are surrounded by an electrolyte. The upstream Teflon membrane protects the cell from exposure to dust and moisture. A capillary O Pb Sauerstoffsensor 3-Elektroden-Sensor Potentiostat diffusion barrier ensures that only a limited quantity of test gas reaches the inside of the cell. This also helps to minimize the pressure inflow. The electro-chemical reaction (charge crossover) takes place at the measuring electrode. The potential conditions of the sensor change as a consequence. The potential changes are measured above the reference electrode. The counter electrode is addressed by a potentiostat (controlled diffusuin) such that the potential changes of the cell are compensated. The oxygen required for this process is drawn from the ambient air to the inside of the cell. Dual electrode sensor for oxygen measurements The electrodes are surrounded by an electrolyte. The upstream Teflon membrane protects the cell from exposure to dust and moisture. The diffusing oxygen causes a reaction at the measuring electrode. As a consequence, the potential conditions of the sensor change and the cell suplies a measuring current. Electronics The electronic system includes an amplifier, a 4-0 ma transmitter and operating elements. The sensor signal is amplified and converted into a 4-0 ma signal. The latter is transmitted to the analysis unit, shown as current value in the display, and finally analyzed. Page from 6 Subject to change without notice! 07/010
4 Mode of function Calibrating the mesuring sensor During calibration the sensor delivers a pulsating output signal. The connected analysis unit thus suppresses an alarm output. A malfunction signal is transmitted at the same time. An additional voltage meter is required for the sensor of the type Gasmonitor because this sensor (unlike the Exmonitor) has no display. There are two options for calibrating: - Direct sensor calibration using test gas: Select the operating mode cal gas. Test gas is applied to the sensor and the unit is calibrated with the help of the display (or the connected measuring instrument when using the Gasmonitor) and the potentiometers for zero and amplification. Finally, the sensitivity (calibration number) of the sensor can be read. - Without test gas using a calibrated sensor: Plug in a sensor filled with test gas. Zero is set in air free of test gas. This sensor carries a calibration number. Finally, using the potentiometer for sensitivity, set the display to the calibration number of the sensor. Technical specifications Sensors Measuregas ment Standard measurement range Special measurement range Resolution (standard range) Response ime T t 90 Repeability of signal Type: Exmonitor- Gasmonitor- CO ppm < 30 Sek. 1% CO 1000 H S < 35 Sek. 1% HS 00 H S ppm ppm < 30 Sek. 1% HS 50 SO ppm < 0 Sek. 1% SO 100 SO ppm 0, < 15 Sek. SO 0 NO < 10 Sek. NO 100 NO ppm 0, < 35 Sek. NO 0 Cl ppm 0, < 60 Sek. Cl 0 HCN < 100 Sek. HCN 100 HCl < 10 Sek. HCl 100 H ppm ppm < 30 Sek. H 1000 O vol % 0,1 vol % < 15 Sek. n.c. O 5 NH ppm < 150 Sek. < 10% NH3 50 NH 3 10 ppm < 60 Sek. < 10% NH /010 Subject to change without notice! Page 3 from 6
5 Technical specifications Type Gasmonitor Exmonitor Measuring principle Measuring signal electro-chemical measuring cell ma Supply voltage on the heat terminals Temperature range -10 C C P erm. humidity 15%... 90% rel. F VDC Note to the lost of voltage on the cable, barrier and on the measurinng-shunt in the controller. Pressure range Storage Temperature Pressure coefficient Expected operating life Max. cable length Connecting cable mbar -10 C C <0,0 % of signal / mbar min years (toxic) 15-4 month (oxygen) 1000 m, depending on cable type -core, screened, on cable length conductor cross-section depending Suitable analysis units GMC 80, GMC80E, GMC840, GMC8364 Unit run-up time Cross sensitivity EC-Type- Examination Directive 94/9/EC Recommendet barrier 30 minutes at first start-up 48 hours with type (NH3-50, NO-100, HCl-100) on request II G Ex ia IIC T4 Gb BVS 03 ATEX E 384 Pi: 660 mw Ui: 8 V Ii: 93 ma Li: <= 4 µh Ci: <= 8 nf -10 C <= Ta <= 50 C Current repeater Page 4 from 6 Subject to change without notice! 07/010
6 Mechanical specifications Designation Gasmonitor Exmonitor Protection class IP 54 Enclosure material Aluminum Polyester Weight Dimensions: H x W x D Cable inlet Terminals 400 g 100 g 170 x 64 x 34 mm 115 x 160 x 75 mm cable diameter -pin 0,5... 1,5 mm from 6 mm up to 1 mm Gasmonitor Exmonitor 0 Cal. Ext. Cal. Gas Measure Exmonitor 115 mm 160 mm 07/010 Subject to change without notice! Page 5 from 6
7 Approval EC-Type-Examination Directive 94/9/EC, electrical safty II G Ex ia IIC T4 Gb BVS 03 ATEX E 384 Equipment Service Test gas set Calibration gases barriers Everything from one source - from project development to the installation of your new gas alarm unit. Guaranteed by our comprehensive sales and service network. Call us for the address of your local contact partner. Our after-sales technicians are pleased to assist you with hands-on help and advice. Bieler + Lang GmbH Gasmess- und Warnsysteme Postfach 119, D-7784 Achern Von-Drais-Straße 31, D Achern Telephone +49 (0) / Telefax +49 (0) / info@bieler-lang.de Internet Page 6 from 6 Subject to change without notice! 07/010
8 ec ec ec hnical hnical hnical Specif Specif Specif ica ica ica tion tion tion tion O-A Oxygen Sensor Figure 1 O-A Schematic Diagram Tec echnical hnical Specifica Specif ication All dimensions in millimetres (± 0.1mm) Top View Bottom View Side View PERFORMANCE Output 0.9% O 80 to 10 Response time t90 (s) from 0.9% to 0% O < 15 Zero current µa in N < Pressure sensitivity (% change of output)/(% change of 0kPa < 0.1 Linearity % O 10% O 0.6 Hysteresis % O change after 16 cycles: 0 to 0.9% O < 0.15 Hand aspirator % O change during aspiration (typical) 19.5 to.5 response LIFETIME Output drift % change in 3 months < 1 Operating life months until 85% original output of 0.9% O > 4 ENVIRONMENTAL Humidity Sensitivity % O change: 0% to 95% 40 C < 0.7 CO sensitivity % (change O reading) / % 5% CO 0.1 PHYSICAL Diameter mm (including label) 0.0 DIMENSIONS Height mm (including foam ring) 16.8 Weight g < 16 KEY Temperature range C -30 to 55 SPECIFICATIONS Pressure range kpa 80 to 10 Humidity range % rh continuous (0 to 99% rh short term) 5 to 95 Storage period 3 to 0 C (store in sealed pot, open circuit) 6 Load resistor Ω (recommended) 47 to 100 NOTE: all sensors are tested at ambient environmental conditions, with 47 ohm load resistor, unless otherwise stated. As applications of use are outside our control, the information provided is given without legal responsibility. Customers should test under their own conditions, to ensure that the sensors are suitable for their own requirements. Alphasense Ltd, Sensor Technology House, 300 Avenue West, Skyline 10, Great Notley. CM77 7AA. UK Telephone: +44 (0) Fax: +44 (0) sensors@alphasense.com Website:
9 ec ec ec hnical hnical hnical Specif Specif Specif Output (ua) ica ica ica tion tion tion tion O-A Perf erformance Data Tec echnical hnical Specifica Specif ication Figure Output Temperature Dependence % output (relative to output at 0 o C) Temperature ( o C) Figure 3 Sensitivity at 50 o C % (sensitivity at 50 o C) / (sensitivity at 0 o C) Nominal Batch Number Figure 4 Long Term Stability Days Figure shows the variation in sensitivity caused by changes in temperature. This plot of the mean and ± 95% confidence intervals for 34 batches shows superior repeatability of the sensitivity dependence from batch to batch, giving confidence when setting temperature compensation in your gas detector. The very stable output over the full lifetime of the O-A shows that Alphasense has solved the problem of poor performance near the end of lifetime. For further information on the performance of this sensor, on other sensors in the range or any other subject, please contact Alphasense Ltd. For Application Notes visit In the interest of continued product improvement, we reserve the right to change design features and specifications without prior notification. The data contained in this document is for guidance only. Alphasense Ltd accepts no liability for any consequential losses, injury or damage resulting from the use of this document or the information contained within it. ( ALPHASENSE LTD ) Doc. Ref. TDS/OA/Issue 13
ExDetector HC-100. Data Sheet. Gas Measuring and Alarm Systems
HC-100 Gas Measuring and Alarm Systems HC-100 Application / Construction The HC100 series of measuring probes, used in conjunction with evaluation systems, have the following functions: Measurement and
More informationExDetector IRCO2. ExDetector IRHC. Operating and Installation Instructions. Gas Detection and Warning Systems
IRCO2 IRHC Operating and Installation Instructions Gas Detection and Warning Systems Important Instructions Prerequisites for safe and reliable operation of the system: Appropriate transport and handling
More informationEC24. Operation Manual. (Type MWG 2411, MWG 2412, MWG 2413 and MWG 2414)
Operation Manual EC24 (Type MWG 2411, MWG 2412, MWG 2413 and MWG 2414) GfG GESELLSCHAFT FÜR GERÄTEBAU MBH KLÖNNESTRASSE 99 D-44143 DORTMUND TELEPHONE +49/(0)231 / 564 00 0 FAX +49/(0)231 / 516313 INFO@GFG-MBH.COM
More informationGAS DETECTOR ST400EC PART.NO
DATA SHEET 1(7) GAS DETECTOR ST400EC PART.NO. 004461-004467 DETECTION OF TOXIC GASES AND OXYGEN SYSTEM GS5000, GS3000, SW2020, BUCONTROL / BUTOUCH GENERAL DESCRIPTION Detection of toxic gases and Oxygen
More informationIR25 Dual Gas Series Datasheet
SGX Europe Sp. z o.o. IR25 Dual Gas Series Datasheet Infrared Dual Gas Sensor for Mining (Portable and Fixed Systems) The SGX infrared sensors use the proven Non-Dispersive Infrared (NDIR) principle to
More informationCMF, CMX & CMA series
Features Electrochemical sensor element 4-20 ma or 2-10 Vdc output CMF- IP 44 protection CMX- IP 54 protection CMA- IP 65 protection Wide supply voltage range (18-28 Vdc) Overload and short cicuit protected
More informationFixed Gas Detection System/Meridian CERTIFICATION
The marking shall include 2 Wire Aluminum Transmitter 3/4 Wire Aluminum Transmitter 2 Wire Stainless Steel Transmitter (PN: 096-3521) (PN: 096-3522) (PN: 096-3525) Ex db [ia Ga] IIC T4 Gb Ex db [ia Ga]
More informationDräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors
Dräger Polytron 5700 Fixed Gas Detector Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors Dräger Polytron 5700 Including e-box for increased safety wiring The Dräger
More informationGas cylinder scale Model GCS-1
Electronic pressure measurement Gas cylinder scale Model GCS-1 WIKA data sheet PE 87.19 Applications Level measurement of liquid gases in gas cabinets and gas distribution systems Level measurement in
More informationStand Alone DYNAGARD SP Operation Manual
Stand Alone DYNAGARD SP Operation Manual Contents Page General Description 1 Detection Principle 1 For Your Safety 1 Design 2 Mounting 2 Mounting Position of DYNAGARD SP 2 Installation of Electrical Connections
More informationUser Manual. PolyGard CO LC-1112 V3. Electrochemical analog carbon monoxide transmitters serial no. EC-S 002. August 29, 2006
PolyGard CO LC-1112 V3 Electrochemical analog carbon monoxide transmitters serial no. EC-S 002 User Manual August 29, 2006 January 04, 2016 Revision Specifications subject to change without notice. USA
More informationMICROpeL 75 Combustible Gas Sensor Part Number: PM
MICROpeL 75 Combustible Gas Sensor Part Number: PM759-000 Key Features & Benefits: ATEX, UL and CSA Approvals Withstands EN/IEC 60079-0 impact test Enhanced H 2 S and silicone poison resistance Reduced
More informationModels TX-KE and TX-KP Toxic Gas Transmitters
Models TX-KE and TX-KP Toxic Gas Transmitters Instruction Manual PureAire Monitoring Systems, Inc. 557 Capital Dr. Lake Zurich, IL. 60047 Phone: 847-726-6000 Fax: 847-726-6051 Toll-Free: 888-788-8050 www.pureairemonitoring.com
More informationMicro III (Models G203, G203S, and G213) Operation Manual
Micro III (Models G03, G03S, and G13) Operation Manual Worldwide Manufacturer of Gas Detection Solutions Table of contents Page Introduction... 3 For your safety... 3 Application and use... 3 General
More informationIR1xxx Series 1, IR2xxx Series 1 Miniature Infrared Gas Sensors for Hazardous Areas and Intrinsic Safety in Mining
IR1xxx Series 1, IR2xxx Series 1 Miniature Infrared Gas Sensors for Hazardous Areas and Intrinsic Safety in Mining FEATURES * Configured for carbon dioxide (IR11BD, IR21BD), hydrocarbons (,,, ) or acetylene
More informationIR15 Dual Gas Series Datasheet
SGX Europe Sp. z o.o. IR15 Dual Gas Series Datasheet Infrared Dual Gas Sensor for Hazardous Environments (Portable and Fixed Systems) The SGX infrared sensors use the proven Non-Dispersive Infrared (NDIR)
More informationMICRO III (G202 / G202s / G212) Single Gas Detector
Operation Manual MICRO III (G202 / G202s / G212) Single Gas Detector GfG GESELLSCHAFT FÜR GERÄTEBAU MBH KLÖNNESTRASSE 99 D-44143 DORTMUND TELEPHONE +49 / (0) 2 31 / 5 64 00 0 FAX +49 / (0) 2 31 / 51 63
More informationIR1 Single Gas Series Datasheet
SGX Europe Sp. z o.o. IR1 Single Gas Series Datasheet Infrared Single Gas Sensor for Hazardous Environments (Portable and Fixed Systems) The SGX infrared sensors use the proven Non-Dispersive Infrared
More informationOperating Instructions Compur Monitox plus
Operating Instructions Compur Monitox plus Subject to changes without notice. Copyright Compur Monitors München Editor: Compur Monitors GmbH & Co. KG Weissenseestr. 101 D-81539 München Content Page Monitox
More informationDräger X-am 5600 Personal Monitor Multi-Gas Detection Device
Dräger X-am 5600 Personal Monitor Multi-Gas Detection Device Featuring an ergonomic design and innovative infrared sensor technology, the Dräger X-am 5600 is the smallest gas detection instrument for the
More informationPressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications
Force Pressure Temperature Switch Pressure sensors Ex ia I / IIC T6 acc. to ATEX with internal diaphragm with front flush diaphragm Accuracy: 0,25% and 0,5 % Standard output: 4...20 ma; 2-wire system Description
More informationSafe Operation Manual. Honeywell IQ Force Gas Detector
Safe Operation Manual Honeywell IQ Force Gas Detector Honeywell Analytics 800-663-4164 403-248-9226 Fax 403-575-3708 03JUN2012 P/N 50105843-047 Version 01 http://www.honeywell.com HONEYWELL IQ Force PERSONAL
More informationLamp Supply (Recommended)
SGX Europe Sp. z o.o. IR600 Datasheet Infrared Gas Sensor for Hazardous Areas (Fixed Systems) The IR600 Series gas sensors are designed to detect and monitor the presence of CO 2, hydrocarbons and acetylene
More informationIR15TT-R Miniature Infrared Gas Sensor for Monitoring Carbon Dioxide and Methane up to 100% Vol.
IR15TT-R Miniature Infrared Gas Sensor for Monitoring Carbon Dioxide and Methane up to 100% Vol. FEATURES Two active gas channels for simultaneous detection of carbon dioxide and methane (or other hydrocarbons)
More informationTransmitters/Sensors. OLCT Series
Transmitters/Sensors Gas Monitoring Solutions OLCT 20-40-50-60 Series SIL2 based on EN 50402 (OLCT 60 based on EN 50271) FLP approved Intrinsically Safe (IS) Precalibrated block module local or remote
More informationIRceL CH4 Methane (CH 4
Product Datasheet IRceL CH4 Methane Sensor Document Purpose The purpose of this document is to present the performance specification of the IRceL CH4 Methane gas sensor. This document should be used in
More informationSITRANS T. SITRANS T Explosion protected temperature sensor. General information. Marking of the degree of protection. Range of uses.
General information 1 Marking of the degree of protection 2 SITRANS T SITRANS T Explosion protected temperature sensor Operating Instructions Range of uses 3 Installation 4 Assembly and disassembly 5 Commissioning
More informationALTAIR 5X Multigas Detector Product Specification
ALTAIR 5X Multigas Detector Product Specification PHYSICAL CHARACTERISTICS Gas delivery Size, pumped unit without IR Size, pumped unit with IR Weight Handling Case material Environmental protection Display
More information4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head
4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head NET DRAFT version 2.1-2008 Pag. 1 4-20mA Cyber - DRAFT version 2.1-2008 Pag.
More informationGas Detection - GD -
s Gas Detection TECHNICAL SPECIFICATIONS Gas Detection DATA SHEE - GD - Continuing development sometimes necessitates specification changes without notice Technical Specifications 2008 GD-00 Gas Measuring
More informationVQ500 Series Combustible Gas Detector Elements
VQ500 Series Combustible Gas Detector Elements FEATURES * Optimised for combustible gases and vapours * Thermal conductivity versions available * Certified flameproof component * Integral pellistors *
More informationDetectors-Transmitters for Flammable, Toxic Gases and Oxygen. Non-intrusive operation via intrinsically safe infrared remote control.
Détecteur de gaz OLCT80 Detectors-Transmitters for Flammable, Toxic Gases and Oxygen Non-intrusive operation via intrinsically safe infrared remote control Disponible en version déportée, ADF ou de SI
More informationAlphasense Application Note AAN 106 HUMIDITY EXTREMES: DRYING OUT AND WATER ABSORPTION
AAN 106 HUMIDITY EXTREMES: DRYING OUT AND WATER ABSORPTION Alphasense electrochemical toxic gas sensors are low power devices with excellent resolution, dynamic range and selectivity. These electrochemical
More informationFREEDOM SERIES 5000 AND 5600 GAS TRANSMITTERS
FREEDOM SERIES 5000 AND 5600 GAS TRANSMITTERS FREEDOM SERIES 5000 & 5600 MAKING INSTALLATION AND EVERYDAY OPERATION EASY The Freedom Series 5000 and 5600 are full-featured 4-20mA, loop powered transmitters
More information4P-90 CiTipeL Combustible Gas Sensor Part Number: PM
Key Features & Benefits: ATEX, UL and CSA Approvals Withstands EN/IEC 60079-0 impact test Enhanced H 2 S and silicone poison resistance 4P-90 CiTipeL Combustible Gas Sensor Part Number: PM143-000 Performance
More informationOilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor
Labkotec UK Ltd Adminicle House 1 Lumb Lane Audenshaw Manchester M34 5WH GREAT BRITAIN Tel: 0844 3350 477 Fax: 0161 4281 179 E-mail: info@labkotec.co.uk 10.8.2012 Internet: www.labkotec.co.uk 1/13 OilSET-1000
More informationCARBON MONOXIDE CO SS SOLID STATE ELECTROCHEMICAL SENSORS
1. DESCRIPTION OF TECHNOLOGY The CO sensor is based on the technology of electrochemical gas detection principle. This technology can be used to detect chemicals or gases that can be oxidized or reduced
More informationDetection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Certifications. The Fixed Gas Detection People
Fixed Gas Detector Detection of explosive gases, toxic gases or oxygen Infrared XP version SIL 2 high reliability IP 66 Certifications The Fixed Gas Detection People The OLC/OLCT CT range of fixed ddetectors
More information5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots
5 Operating Modes GX-6000 Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots GX-6000 5 Operating modes Normal Leak Check Inert Bar hole Snap Log Monitor up to
More informationTransmitter for O 2 ZD21. Operation Manual
Transmitter for O 2 ZD21 Operation Manual Table of contents Page For your Safety...4 General Description...4 Detection Principle...5 Operational Notes...5 Design...5 Mounting Position...6 Mounting...7
More information5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots
5 Operating Modes GX-6000 Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots CONFINED SPACE ENTRY Monitor LEL, O2, CO, and H2S Internal sample pump Pull samples
More informationDräger Polytron 8000 Stationary gas detector (EC)
Dräger Polytron 8000 Stationary gas detector (EC) The microprocessor-based transmitter can be equipped with various electrochemical DrägerSensors. This way, you can easily detect oxygen and various toxic
More information4P75 CiTipeL Combustible Gas Sensor Part Number: PM
Product Datasheet 4P75 Document Purpose The purpose of this document is to present the performance specification of the 4P75 CiTipeL. This document should be used in conjunction with Operating Principles
More informationElectrochemical (EC) DrägerSensors for Fixed Gas Detectors
Electrochemical (EC) DrägerSensors for Fixed Gas Detectors When you need to selectively measure the smallest concentrations of airborne toxic gases and oxygen under ambient conditions, Electrochemical
More informationEU DECLARATION OF CONFORMITY
The Low Voltage Directive (LVD) 2014/35/EU and Electromagnetic Compatibility (EMC) Directive 2014/30/EU. Capacitive level sensor DLS 27N(T) Capacitive level sensor type DLS 27N(T) is designed to bistable
More informationSieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required
Sieger Sensepoint The Sensepoint range of flammable, toxic and oxygen gas detectors offer users a high quality, low cost solution to their industrial gas monitoring needs. Sieger Sensepoint Fit For Purpose
More informationDatasheet: K-22 LO Sensor
Datasheet: K-22 LO Sensor The K- 22 LO is a CO2 sensor module designed to be built- in into stationary ventilation equipment, such as window vent or duct exhaust actuators, serving as a linear transmitter
More informationDräger Polytron 5700 IR Detection of flammable gases and vapours
Dräger Polytron 5700 IR Detection of flammable gases and vapours The Dräger Polytron 5700 IR is a cost effective explosion-proof transmitter for the detection of flammable gases in the lower explosive
More informationDifferential Pressure and Flow Meter Media 5 Indicator 160 PN 40
Differential Pressure and Flow Meter Media 5 Indicator 160 PN 40 Application Instrument designed to measure and indicate differential pressure or measured variables derived from it For gases or liquids
More informationDetection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Aluminium or Stainless Steel version
Fixed Gas Detector Detection of explosive gases, toxic gases or oxygen Infrared XP version SIL 2 high reliability IP 66 Aluminium or Stainless Steel version Certifications Pending The Fixed Gas Detection
More informationtesto 316-EX gas leak detector Instruction manual
testo 316-EX gas leak detector Instruction manual 2 1 Safety and the environment 1 Safety and the environment 1.1. About this document Use > Please read this documentation through carefully and familiarize
More informationDräger Polytron 8700 IR Detection of flammable gases and vapors
Dräger Polytron 8700 IR Detection of flammable gases and vapors The Dräger Polytron 8700 IR is an advanced explosion proof transmitter for the detection of combustible gases in the lower explosion limit
More informationIntrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20
Electronic Pressure Measurement Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20 Applications Chemical, Petrochemical
More informationBA334D Intrinsically safe Externally powered pulse input field mounting rate totaliser Issue 13
TR Automatyka Sp. z o. o. Tel. (+48 022) 886 10 16 www.trautomatyka.pl ul. Lechicka 14 ; 02-156 Warszawa Fax. (+48 022) 846 50 37 biuro@trautomatyka.pl BA334D Intrinsically safe Externally powered pulse
More informationDräger X-am 5000 Multi-Gas Detection
Dräger X-am 5000 Multi-Gas Detection The Dräger X-am 5000 belongs to a generation of gas detectors, developed especially for personal monitoring applications. This 1- to 5-gas detector reliably measures
More informationTechnical Data. General specifications. Rated operating distance s n 5 mm
0102 Model Number Features 5 mm non-flush Usable up to SIL 2 acc. to IEC 61508 Technical Data specifications Switching function Normally closed (NC) Output type NAMUR Rated operating distance s n 5 mm
More informationBA338C Intrinsically safe Externally powered pulse input panel mounting rate totaliser issue 13
BA338C Intrinsically safe Externally powered pulse input panel mounting rate totaliser issue 13 Certification information label Total display Rate display Rotating flow indicator Annunciators for optional
More informationTechnical Data. Dimensions
0102 Model Number Features 8 mm non-flush Stainless steel housing Usable up to SIL2 acc. to IEC 61508 Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 8 mm
More informationRK Hydrogen Sulfide Transmitter Operator s Manual
65-2331RK Hydrogen Sulfide Transmitter Operator s Manual Part Number: 71-0176RK Revision: B Released: 11/26/14 RKI Instruments, Inc. www.rkiinstruments.com WARNING Read and understand this instruction
More informationInductive slot sensor
0102 Model Number Features 2 mm slot width Technical Data specifications Switching function Normally closed (NC) Output type NAMUR Slot width 2 mm Depth of immersion (lateral) 5... 7 mm, typ. 6 mm Output
More informationTechnical Data. General specifications Switching element function Rated operating distance s n 5 mm
0102 Model Number Features 5 mm non-flush Usable up to SIL2 acc. to IEC 61508 Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 5 mm Installation non-flush
More informationDocumentation. Explosion-Protection. for Smoke Detection Panels SDS-4, SDS-8, SDS-12 and Extension Panels SDS-E8, SDS-E12, SDS-E16, SDS-EC16
safetec Documentation Explosion-Protection for Smoke Detection Panels SDS-4, SDS-8, SDS-12 and Extension Panels SDS-E8, SDS-E12, SDS-E16, SDS-EC16 in Smoke Detection System SDS-48 according IEC 60079-25
More informationModel 144H. Product Data Sheet , Rev DB February Content
Rosemount 144 PC-Programmable Temperature Transmitter Provides an installation-ready solution for temperature monitoring applications using Complete Point Solutions (CPS) Increases measurement accuracy
More informationElectrochemical DrägerSensor Sensors for Fixed Gas Detectors
Electrochemical DrägerSensor Sensors for Fixed Gas Detectors Fast response, high accuracy, great stability, long life. Electrochemical DrägerSensors offer all these benefits. You can use the robust and
More informationDräger X-am 5000 Multi-Gas Detection
Dräger X-am 5000 Multi-Gas Detection The Dräger X-am 5000 belongs to a generation of gas detectors, developed especially for personal monitoring applications. This 1- to 5-gas detector reliably measures
More informationOLC(T) 100 FIXED GAS DETECTOR
Fixed Gas Detector OLC(T) FIXED GAS DETECTOR Detection of explosive gases, toxic gases or oxygen Infrared XP version SIL 2 high reliability IP 66 Aluminium or Stainless Steel version CERTIFICATIONS The
More informationModel 144H. Product Data Sheet , Rev DB February Content
Rosemount 144 PC-Programmable Temperature Transmitter Provides an installation-ready solution for temperature monitoring applications using Complete Point Solutions (CPS) Increases measurement accuracy
More informationDruck DPI 705/DPI 705 IS Series
GE Sensing & Inspection Technologies 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Druck DPI 705/DPI 705 IS Series Digital Pressure
More informationAnnubar Flowmeter Series
Reference Manual Appendix B Approvals Annubar Flowmeter Series Hazardous Locations Installations.................. page B-1 Rosemount 3051SFA Product Certifications.......... page B-1 Rosemount 3095MFA
More informationMicro IV Operation Manual
Micro IV Operation Manual Worldwide Manufacturer of Gas Detection Solutions TABLE OF CONTENTS Page Introduction...4 For Your Safety...4 Application and Use...4 General Description...4 Detection Principle...5
More informationDräger Polytron 5720 IR Toxic Gas Detection
Dräger Polytron 5720 IR Toxic Gas Detection The Dräger Polytron 5720 IR is a cost-effective explosion proof transmitter for the detection of carbon dioxide in volume percentage or ppm It uses a high-performance
More informationDräger Polytron (approved as type P3S) Transmitter for electrochemical Sensors. Instructions for Use. ST eps
D Dräger Polytron 3000 (approved as type P3S) Transmitter for electrochemical Sensors Instructions for Use ST 691 2002.eps Contents Contents For Your Safety............................................................
More informationP R O D U C T D ATA S H E E T
TOCSIN 750 SERIES ANNUNCIATORS Addressable Gas Detection Interface Point -Wire Addressable Systems Sounder Display Shows: Reading-Message-Alarm RGB Relay Output off Solid State Beacon Sounder Output off
More informationGMS-10 RVS Series. Oxygen Sensors Accurate oxygen measurement WARNING WARNING DESCRIPTION TYPICAL APPLICATIONS FEATURES MISUSE OF DOCUMENTATION
GMS-10 RVS Series Oxygen Sensors Accurate oxygen measurement DESCRIPTION The GMS-10 is a high-accuracy oxygen sensor suitable for many applications. Originally developed for boiler applications, the product
More informationDifferential Pressure and Flow Meter. Media 5 Indicator 160 Ø PN 50
Differential Pressure and Flow Meter Media 5 Indicator 160 Ø PN 50 Application Transmitter for measuring and indicating the differential pressure or measured variables derived from it Suitable for gases
More informationDräger Polytron 5200 CAT Detection of flammable gases and vapours
Dräger Polytron 5200 CAT Detection of flammable gases and vapours The Dräger Polytron 5200 CAT is a cost-effective explosion-proof transmitter for the detection of flammable gases in the lower explosion
More information4) Intrinsic Safety Certification
INSTRUCTION MANUAL Minialert Intrinsically Safe Round Combined Unit Section Volume Control Tone Generator S2 S3 Tone Selection Switches Fig 1 Simplified block diagram The combined unit is CE marked for
More information3M Oldham OLCT 100. Description. Fixed Gas Detector
Fixed Gas Detector Description The OLC/OLCT range of fixed detectors has been designed for detection of combustible gases, toxic gases or oxygen. Available in explosion-proof or intrinsically safe versions,
More informationSieger Apex. Flexibility that meets your requirements
Sieger Apex Flexibility that meets your requirements Sieger Apex Easy to Install Sensor can be remotely mounted up to 100m from the transmitter On board relays allow for local audible/ visual alarms Strong
More informationSensepoint. Fit For Purpose Flammable, toxic and Oxygen versions available High performance, low cost Suitable for new and retro fit applications
Sensepoint The Sensepoint range of flammable, toxic and Oxygen gas detectors offer users a high quality, low cost solution to their industrial gas monitoring needs. Sensepoint Fit For Purpose Flammable,
More informationDräger Polytron SE Ex Fixed Gas Detector
Dräger Polytron SE Ex Fixed Gas Detector The Dräger Polytron SE Ex... DD sensing heads are gas detectors for the continuous monitoring of flammable gases and vapors in the ambient air. The measurement
More informationATEX GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres. Directive 94/9/EC
Quick Introduction to TÛV Denmark TÜV Denmark - is a part of the TÜV NORD Group a global Organisation f Certification and Inspection of: Quality Management Systems, Products, Processes and Qualification
More informationALTAIR 5X Multigas Detector
ALTAIR 5X Multigas Detector With MSA XCell Sensor Technology IT S WHAT S INSIDE THAT COUNTS Now with advanced PID for VOC Detection Because every life has a purpose IT S WHAT S INSIDE THAT COUNTS WORKERS
More informationPEPPERL+FUCHS GmbH
Comfort series 1.5 mm embeddable M8x1 4 25 16 13 LED Switching element function NAMUR NC Rated operating distance s n 1,5 mm Installation embeddable Assured operating distance s a 0... 1,215 mm Reduction
More informationRK Carbon Monoxide Transmitter Operator s Manual
65-2434RK Carbon Monoxide Transmitter Operator s Manual Part Number: 71-0061RK Edition: First, Revision C Released: December 2001 65-2434RK CO Transmitter 1 Product Warranty RKI Instruments, Inc., warranties
More informationUser Manual. GPD 3000 e. gas detector
User Manual GPD 3000 e gas detector Table of contents Application...3 Unit ppm, Vol.%...4 Operation elements GDP 3000 e...5 Gas sensor...6 Important Information off sensor!...6 Measurement range...7 Turning
More informationFAHM Co. Temperature Transmitter PTT74 Series
FAHM Co. PTT74 Series The PTT74 is a versatile temperature transmitter that delivers field reliability and advanced accuracy and stability to meet demanding process needs. PTT74 Family of Transmitters
More informationDräger X-am 7000 Multi-Gas Detection
Dräger X-am 7000 Multi-Gas Detection Dräger X-am 7000 is the solution for the simultaneous and continuous measurement of up to five gases. It is the ideal companion in a variety of applications where the
More informationREGARD. REGARD 4-20 AND Ex CHANNEL CARDS INSTALLATION AND OPERATING MANUAL (FOR ATEX VERSION CARDS)
REGARD REGARD 4-20 AND Ex CHANNEL CARDS INSTALLATION AND OPERATING MANUAL (FOR ATEX VERSION CARDS) Part No. 4206712 For use with Regard 4-20 and Ex cards software version 3.0 or later. Draeger Safety UK
More informationSIMRAD GD10PE IR GAS DETECTOR
SIMRAD GD10PE IR GAS DETECTOR Operating Manual P3404E 1st edition Jan. 2004 www.simrad-optronics.com CONTENTS 1. PRODUCT DESCRIPTION... 5 1.1 General description... 5 1.2 Construction... 5 1.3 Application
More informationMICRO IV. Operation Manual. Single Gas Detector
Operation Manual MICRO IV Single Gas Detector GfG GESELLSCHAFT FÜR GERÄTEBAU MBH KLÖNNESTRASSE 99 D-44143 DORTMUND TELEPHONE +49 / (0) 2 31 / 5 64 00 0 FAX +49 / (0) 2 31 / 51 63 13 INFO@GFG-MBH.COM WWW.GASDETECTION.BIZ
More informationDräger Polytron 8720 IR Detection of carbon dioxide
Dräger Polytron 8720 IR Detection of carbon dioxide The Dräger Polytron 8720 IR is an advanced explosion proof transmitter for the detection of carbon dioxide in percent volume or ppm It uses a high performance
More informationCT-7 Series Toxic Gas Transmitter Operator s Manual
65-2341 CT-7 Series Toxic Gas Transmitter Operator s Manual Part Number: 71-0424 Revision: P1 Released: 6/8/17 RKI Instruments, Inc. www.rkiinstruments.com WARNING Read and understand this instruction
More informationDräger Polytron 8700 IR Detection of flammable gases and vapors
Dräger Polytron 8700 IR Detection of flammable gases and vapors The Dräger Polytron 8700 IR is an advanced explosion proof transmitter for the detection of combustible gases in the lower explosion limit
More informationL+T GASETECHNIK. Klöpper-Waldmann GmbH & Co. K G. Alarm unit LSG4
Areas of application The LSG4 alarm unit is used for monitoring industrial systems, e.g. in the following areas: Alarm and hazard stati in production e.g. for monitoring temperature and pressure in reactors
More informationDräger X-am 2500 Multi-Gas Detection
Dräger X-am 2500 Multi-Gas Detection The Dräger X-am 2500 was especially developed for use as personal protection. The 1 to 4 gas detector reliably detects combustible gases and vapours, as well as O2,
More informationDräger X-zone 5500 Area Monitoring
Dräger X-zone 5500 Area Monitoring Dräger's X-zone 5500 brings a safer, more effective way to monitor hazardous gases--reinventing area monitoring. In combination with the Dräger X-am 5000, 5100, or 5600
More informationOLCT 10N. Digital Gas Detector. User Manual. The Fixed Gas Detection Experts. Part Number: NPO10NEN Version: G.1
User Manual OLCT 10N Digital Gas Detector Part Number: NPO10NEN Version: G.1 The Fixed Gas Detection Experts Copyright 2015 by OLDHAM S.A.S May 2015 All rights reserved. No reproduction of all or part
More informationTechnical Data. Dimensions
0102 Model Number Features 5 mm flush Usable up to SIL2 acc. to IEC 61508 Accessories EXG-18 Quick mounting bracket with dead stop BF 18 Mounting flange, 18 mm Technical Data specifications Switching element
More informationSENSE Instruments CO., LTD. Data sheet Gas detector Page 1 / 5. Gas detector
Page 1 / 5 Gas detector Brief SEN series smart gas transmitter changes the gas concentration into standard 4~20mA current source signal, Online free parking digital free configuration,multi-parameter backlight
More information