1 th Street Lubbock, Texas ADDENDUM NO: 01 TO: ALL PLANHOLDERS FROM: PARKHILL, SMITH, & COOPER, INC. PROJECT NAME: FIRE STATION ADDITION AND RENOVATION PROJECT NO.: DATE: 07/22/ /22/15 Attention of all Prospective Proposers/Plan Holders is directed to the following modifications to the referenced Drawings and Project Manual. This Addendum becomes a part of the Contract Documents and modifies the original Contract Documents dated July 2015 as noted below: This Addendum consists of two page and SECTION I. CHANGES TO PROJECT MANUAL: A. SECTION AGREEMENT 1. REVISE Paragraph 1.1.A.1 to read as follows: AIA A , Standard form of Agreement Between Owner and Contractor where Basis of Payment is Stipulated Sum, as amended, and B , Standard Form of Architect s Services: Design and Construction Contract Administration, as amended and AIA A , General Conditions of the Contract for Construction, as amended. B. SECTION HARDWARE 1. Add this section in its entirety as attached to this addendum. C. SECTION QUALITY REQUIREMENTS 1. REVISE Paragraph 1.8.A. to read as follows: Employ and pay for services of an independent testing agency or laboratory meeting requirements specified in Section Testing Laboratory Services. D. SECTION BRICK UNIT MASONRY 1. REVISE Paragraph 2.2.A.2 to read follows: Sizes and Shapes: Nominal king size of 2 ¾ w x 2 5/8 h x 9 5/8 I and nominal queen size of 2 ¾ w x 2 5/8 h x 8 5/8 I. 2. REVISE Paragraph 3.3.B.2.b to read as follows: King and Queen coursing: Five units and five mortar joints to equal 16 inches. E. SECTION PREENGINEERED BUILDINGS 1. REVISE Paragraph 1.7.B.5 change Collateral Loads from 7 psf to 15 psf. II. CHANGES TO DRAWINGS: A. SHEET C102 SITE PLAN 1. Pavement Scope Clarification a. Asphalt pavement is by the owner including earthwork and flexible base within these limits. \\Data1\Projects\2014\ \BIDPROPOSAL PHASE\ADDENDUM NO.01\PSCArch Addenda.docm Abilene Amarillo El Paso Las Cruces Lubbock Midland team-psc.com

2 Addendum No.01 Page 2 July 22, 2015 b. Contractor to construct the building pad, concrete paving, and sidewalk/flatwork including the grading, and any subgrade and/or base material according to the details and specifications. Coordinate with owner on limits of demolition due to overlap and phasing the construction. 2. The fire hydrant is to be relocated by the owner. Coordinate the bollards with the owner after they have installed the fire hydrant. B. SHEET C Water line encasement of existing line crossing under new bay is to be supplied and installed by owner. 2. Fire Hydrant relocation and necessary lead line to be supplied and installed by owner C. SHEET C This plan can be modified to fit the construction sequencing and must be coordinated with the owner. It is a living document intended to be modified as construction progresses. D. SHEET G Add note #3: Thermal Envelope Requirements (IECC Table C402.2): Roofs: Metal Buildings (with R5 Thermal Blocks) R19 + R11 LS, Walls: Above Grade :Metal Buildings R13 + R13CL. E. SHEET S Under 3. Design loads, replace C with following: C. Collateral Load: 15 psf. F. SHEET A Add remark to Door 124 & 108: Over all frame height 8 0 in DOOR SCHEDULE. 2. Add to IHMPF = INSULATED HOLLOW METAL, PAINT FIN. To 2 CONSTRUCTION/VENEER under DOOR SCHEDULE FOOTNOTES. 3. Change door construction of Door 124 & 134 to IHMPF in DOOR SCHEDULE. 4. Change Door 133F, Door Construction to EXISTING and Frame Construction to EXISTING in DOOR SCHEDULE. 5. Change the door construction of Door 132 to HMPF in DOOR SCHEDULE. 6. Change all doors with construction SCTF to SCLP in DOOR SCHEDULE. 7. Add section to DOOR SCHEDULE FOOTNOTES: 8 FIRE RATING and Add L1= 20 Minute Fire Rating. 8. Change details of door 130, 134, 134A: Head B3 A701A, Jamb A3 A701A, Sill A4 A701A in DOOR SCHEDULE. 9. Change Door 100 frame construction to AL01 in DOOR SCHEDULE. 10. Change all glazing tags to G22 in AL06 of the Aluminum Storefront Schedule. End of Addendum.

3 SECTION HARDWARE PART 1 - GENERAL 1.1 SUMMARY 07/22/2015 A. Section Includes: 1. All finish hardware necessary for completion of project. B. Related Sections: 1. Section Custom Casework: Casework Hardware. 2. Section Steel Doors and Frames. 3. Section Steel Frames. 4. Section Wood Doors. 5. Section Flush Wood Doors. 6. Section Overhead Coiling Doors: Hardware for same except cylinders. 7. Section Sectional Overhead Doors: Hardware for same except cylinders. 8. Section Aluminum Entrances and Storefronts: Hardware for same except cylinders. 9. Section Fire Alarm and Smoke Detection System: Electrical connection to activate door closers. 1.2 QUALITY ASSURANCE A. Manufacturers Qualifications: 1. Companies specializing in manufacturing door hardware with minimum three years' experience. B. Regulatory Requirements: 1. Fire Door Hardware: a. Conform to requirements of NFPA 80 and 101 for doors shown, scheduled, or specified to be in a fire rated wall or to receive a UL label. b. In case of conflict between hardware specified and NFPA requirements, provide type required by NFPA. c. Provide door hardware listed by UL or Warnock Hersey or other testing laboratory approved by code authority having jurisdiction. d. Provide hardware tested in accordance with NFPA REFERENCES A. National Electrical Manufacturer's Association (NEMA LB3-1995) - Performance Standards for High Pressure Decorative Laminate. B. American National Standards Institute (ANSI): 1. ANSI A117 Building and Facilities - Providing Accessibility and Usability for Physically Handicapped People. 2. ANSI A156.1 Butts and Hinges. 3. ANSI A156.2 Bored and Preassembled Locks and Latches. 4. ANSI A156.3 Exit Devices. 5. ANSI A156.4 Door Controls - Closers. 6. ANSI A156.5 Auxiliary Locks & Associated Products. 7. ANSI A156.6 Architectural Door Trim HARDWARE

4 8. ANSI A156.7 Template Hinge Dimensions. 9. ANSI A156.8 Door Controls - Overhead Holders. 10. ANSI A Interconnected Locks & Latches. 11. ANSI A Mortise Locks & Latches. 12. ANSI A Closer Holder Release Devices. 13. ANSI A Auxiliary Hardware. 14. ANSI A Self-Closing Hinges and Pivots. 15. ANSI A Materials and Finishes. 16. ANSI A Thresholds. 17. ANSI A Door Gasketing Systems. 18. ANSI A Electromagnetic Locks. 19. ANSI A Delayed Egress Locks. 20. ANSI A Continuous Hinges. 21. ANSI A Auxiliary Locks. C. American Society for Testing & Materials (ASTM): 1. ASTM F883 Padlocks. D. Builders Hardware Manufacturers Association (BHMA): 1. BHMA Directory of Certified Locks & Latches. 2. BHMA Directory of Certified Door Closers. 3. BHMA Directory of Certified Exit Devices. 4. BHMA Directory of Certified Electromagnetic and Delayed Egress Locks. E. Code of Federal Regulations (CFR): 1. 36CFR Part Americans With Disabilities Act (ADA). F. Door and Hardware Institute (DHI): 1. DHI-02 Installation Guide for Doors and Hardware. 2. DHI-03 Keying Systems and Nomenclature. 3. DHI-04 Recommended Locations for Builders' Hardware for Custom Steel Door and Frames. 4. DHI-05 Recommended Locations for Builders' Hardware for Standard Steel Doors and Frames. 5. DHI A115 Wood Door Preparation Standards. G. National Fire Protection Association (NFPA): 1. NFPA 80 Fire Doors and Windows. 2. NFPA 101 Code for Safety to Life from Fire in Buildings and Structures. 3. NFPA 105 Installation of Smoke and Draft Control Door Assemblies. 4. Steel Door Institute (SDI): 5. SDI-107 Hardware on Steel Doors (Reinforcement and Application). H. Underwriter s Laboratories, Inc. (UL): 1. Building Materials Directory. 1.4 SUBMITTALS A. Product Data: 1. Provide product data on specified hardware. 2. Submit manufacturer's parts lists, templates, and installation instructions. 3. Provide wiring diagrams, electrical characteristics, and product data on all electrically controlled devices. B. Hardware Schedule: 1. Include for each item: Quantities; manufacturer's name and catalog numbers; sizes; detail information or catalog cuts; finishes; door and frame size and materials; location and hardware set identification using same opening numbers as indicated on HARDWARE

5 the drawings; lock trim material thicknesses; lock trim material evaluation test results; corresponding ANSI/ BHMA standard type number or function number from manufacturer's catalog if not covered by ANSI/BHMA; and list of abbreviations. 2. Indicate locations and mounting heights of each type of hardware. 3. Indicate lock side of single cylinder doors. 4. Include master cross-reference list indicating door numbers in numerical sequence and associated hardware set. a. If, for any reason, any door is moved from the hardware set indicated in the schedule at the end of this section, provide a master cross-reference list, in numerical sequence, indicating door number, original hardware set and new hardware set for every opening. C. Keying Schedule: 1. Hold a keying conference with the Owner or Owner's representative to develop a keying schedule. 2. Develop schedule in accordance with DHI Obtain keying system approval before delivering hardware to project. 4. Unless otherwise indicated or requested, provide keying as follows: a. Key all doors different and key all doors to the same room alike. b. Key all exterior doors alike. c. Master key all doors except mechanical room doors to one key. d. Key mechanical room doors to existing utilities master key system. D. Certificates of Compliance: 1. Submit certificates of compliance attesting that hardware items conform to the NFPA, CFR and ANSI/ BHMA standards specified. 2. Fire Rated Doors: Submit certificates of compliance, attesting that doors which are indicated, scheduled, or specified to be fire rated are fitted with the required hardware (i.e., active latch bolts, self-closing devices) and operate in accordance with the requirements of NFPA 80 and 101. Identify all such doors on certificates. E. Closeout Submittals: 1. Submit in accordance with Section Provide list of actual locations of installed cylinders and their master key code. 3. Submit data on operating hardware, lubrication requirements adjustment methods and inspection procedures related to preventative maintenance. 4. Furnish spare parts data, including a complete list of parts and supplies and source of supply, for locksets, exit devices, closers, electronic locking devices and electromagnetic closer holder release devices. 5. Submit special tools required for hardware adjustment or control. 6. Maintenance Instructions: Furnish 6 complete copies of maintenance instructions listing routine maintenance procedures, possible breakdowns and repairs, and troubleshooting guides. 1.5 DELIVERY, STORAGE, AND HANDLING A. Deliver, store, and handle hardware to site in accordance with provisions of Section B. Individually package each article of hardware in manufacturer's standard commercial carton or container, and properly mark or label to be readily identifiable with approved hardware schedule. C. Tag or otherwise identify each change key with door for which its cylinder is intended HARDWARE

6 1.6 COORDINATION A. Coordinate requirements for hardware to be mounted on metal doors or metal frames between hardware manufacturer and door or frame manufacturer to establish location, reinforcement required, size of holes, and similar details. 1.7 WARRANTY A. Provide twenty-five year warranty for door closers. 1.8 EXTRA MATERIAL A. Blank keys: Provide 50 total. B. Provide extra cylinder cores as scheduled. PART 2 - PRODUCTS 2.1 ACCEPTABLE MANUFACTURERS A. Hinges: 1. Bommer Industries; Landrum, SC. 2. Hager Companies; St. Louis, MO. 3. McKinney Products Company; Scranton, PA. 4. Stanley Hardware Division, Stanley Works; New Britain, CT. B. Lock and Latches: 1. Corbin/Russwin Architectural Hardware; Berlin, CT. 2. Sargent Division ESSEX Industries Inc.; New Haven, CT. C. Push/Pulls: 1. Elmes Door Hardware, Teramura International Corporation; Torrance, CA. 2. Hager Companies; St. Louis, MO. 3. Rockwood Manufacturing Co.; Rockwood, PA. 4. Triangle Brass Manufacturing Co.; Los Angeles, CA. D. Access Control Locks: 1. Alarm Lock; Amityville, NY. E. Exit Devices: 1. Corbin/Russwin Architectural Hardware; Berlin, CT. 2. Sargent Division ESSEX Industries Inc.; New Haven, CT. F. Closers: 1. Corbin/Russwin Architectural Hardware; Berlin, CT. 2. Sargent Division ESSEX Industries Inc.; New Haven, CT. G. Overhead Holders: 1. Glynn-Johnson; Indianapolis, IN. 2. Rixson Architectural Hardware; Charlotte, NC. H. Manual and Automatic Bolts: 1. Door Controls International (DCI); Dexter, MI. 2. Glynn-Johnson; Indianapolis, IN. 3. H.B. Ives, Harrow Co; Wallingford, CT. 4. Triangle Brass Manufacturing Co.; Los Angeles, CA. I. Gasketing/Threshholds: 1. Hager Companies; St. Louis, MO. 2. Pemko Manufacturing Co.; Memphis, TN HARDWARE

7 3. Reese Enterprises, Inc.; Rosemount, MO. 4. Zero International, Inc.; Bronx, NY. J. Protection Plates and Door Edgings: 1. InPro Corporation; Muskego, WI. K. Door Stops/Bumpers: 1. Elmes Door Hardware, Teramura International Corporation; Torrance, CA. 2. Glynn -Johnson; Indianapolis, IN. 3. Hager Companies; St. Louis, MO. 4. H.B. Ives, Harrow Co.; Wallingford, CT. 5. Triangle Brass Manufacturing Co.; Los Angeles, CA. L. Door Silencers: 1. Glynn-Johnson; Indianapolis, IN. 2. H.B. Ives, Harrow Co.; Wallingford, CT. 3. Triangle Brass Manufacturing Co.; Los Angeles, CA. M. Substitutions: Under provisions of Section COMPONENTS A. General: 1. Provide hardware components as indicated in paragraph HARDWARE SCHEDULE at the end of this section. 2. Schedule is based on products manufactured by Alarm Lock, PBB, Pemko, IPC, MMF, Rockwood, Sargent. Components of other manufacturers will be acceptable provided they comply with the ANSI/BHMA standards for Grade 1 products and are listed in the latest edition of the BHMA Directories of certification. 3. Regardless of whether or not the HARDWARE SCHEDULE at the end of this section has every door and every component scheduled for each opening, provide all components required to make every opening functional based on hardware scheduled for similar openings and the referenced codes. B. Locksets: 1. Locksets shall be T-Zone Line construction as manufactured by Sargent & Company. 2. Furnish locksets compatible with specified cylinders. 3. Furnish standard strikes with extended lips to protect trim from being marred by latch bolt. Match cutouts provided in metal frames. a. Mortise Locksets: ANSI A156.13, Series 1000, Grade 1 unless otherwise indicated. b. Bored (Cylindrical) Locksets: 1) ANSI A156.2, Series 4000, Grade 1 unless otherwise indicated. 2) Typical 2-3/4 inch backset. c. Preassembled (Unit) Locksets: ANSI A156.12, Series 2000, Grade 1 unless otherwise indicated. d. Interconnected Locksets: ANSI A156.12, Series 5000, Grade 1 unless otherwise indicated. e. Auxiliary Locksets: ANSI A156.36, Grade 1, bored dead locks, unless otherwise indicated. C. Latch Sets: 1. Latchsets shall be T-Zone Line construction as manufactured by Sargent & Company. 2. Typical 2-3/4 inch backset HARDWARE

8 3. Furnish standard strikes with extended lips to protect trim from being marred by latch bolt Match cutouts provided in metal frames. a. Mortise Latch Sets: ANSI A156.13, Series 1000, Grade 1 unless otherwise indicated. b. Bored (Cylindrical) Latch Sets: ANSI A156.2, Series 4000, Grade 1 unless otherwise indicated. D. Exit Devices and Exit Device Accessories: 1. Provide dust proof floor strikes for vertical rod devices. 2. Door Lite Coordination: a. Mount centerline of exit devices on doors containing door lites approximately at 38-1/2. b. Coordinate with door manufacturer. Lower the centerline of the exit device if needed to locate the exit device below the door lite frame. c. With approval from the Architect, provide manufacturer s standard filler to extend exit device beyond door lite frames where door lites extend below exit device. Factory cut or form filler to match profile of exit device trim. E. Access Control Locks: 1. Access Control Locks to be Trilogy Networx series as manufactured by Alarm Lock of Amityville, NY. 2. Locks shall conform to ANSI A156 Grade 1 3. Provide configuration of lock as required by hardware group: 1) Cylindrical Lock Type: (a) Proximity/keypad - Model Series PDL6100. F. Programming: 1. All programming, including user credentials, scheduling and audit trail retrieval, shall be performed using Alarm Lock DL-Windows software version 4.1.9x or higher. 2. Communication of all programming from computer containing software to locks shall be through Alarm Lock Gateway model appropriate for building s network system. a. Gateway: 1) Ethernet connected gateway - Model Series AL-IME. 2) Power over Ethernet connected gateway, plenum rated - Model Series AL-IMEPOEP. 3) Wi-FI connected gateway - Model Series AL-IM G. Lock Features: 1. Locks, except keypad switch type, to be battery powered by 4 each C size batteries providing 5 year life under normal operating conditions. 2. Locks to support up to 5000 users with 3-6 digit numeric PIN code, or HID format proximity credential, or both for dual credential requirement. 3. Locks to support up to 500 event schedules. 4. Locks to support in non-volatile memory 35,000 event audit trail. 5. Locks to be weatherproof for indoor or outdoor use in operating temperature range of -31 to +151 degrees Fahrenheit. 6. Locks shall continue to operate as last instructed including maintaining schedules and audit trail, independent of building network system failure. 7. Locks shall be capable of providing a system-wide global emergency lockdown/ unlock within 10 seconds when initiated by authorized user from any lock, or from the DL-Windows software. 8. Locks shall adjust schedules automatically to correspond with daylight savings time. 9. Locks shall have remote release capability through hard-wired connection HARDWARE

9 10. Locks shall have a single pole, double throw relay output to provide external functions through hard-wired connection. H. Gateway Features: 1. Each gateway shall support up to 63 locks. 2. Each gateway to communicate to software through the building s network system. a. Ethernet connected gateway: 1) Interface: Ethernet 10Base-T or 100Base-TX. 2) Protocols: TCP/IP, UDP/IP, DHCP. b. Wi-Fi connected gateway: 1) Wireless standards: IEEE b; g. 2) Frequency range: GHz. 3) Output power: 14 dbm dbm/-1.0 dbm. 4) Maximum receive level: -10dBm (with PER <8%). 5) Data rates with automatic fallback: 54Mbps - 1Mbps. 6) Range: up to 328 feet indoors. 7) Modulation techniques: OFDM, DSSS, CCK, DQPSK, DBPSK, 64 QAM, 16 QAM. 8) Interface: b, g, and 10/100 Ethernet. 9) Protocols: TCP/IP, UDP/IP, DHCP. c. Security: IEEE PSK with 128-bit AES Rijndael Encryption. 3. Each gateway to communicate to locks through 900 MHz GFSK proprietary 128-bit encryption: a. 50 channels. b. 10mW power output. 4. Environment: a. Indoor installation. b. Operating temperature: -4 to +140 degrees Fahrenheit. I. Software: 1. Software to be Alarm Lock DL-Windows supporting 2000 locks per system account with a maximum of 50 gateways per system account. J. Security Mode: 1. Security is the essence of this section. Unless otherwise required by code, wireless operated hardware shall remain secured in the event of power failure. Normal operation will require battery power to operate the Networx locks. Emergency mechanical key override shall be provided in the event of battery failure (except for keypad only unit). The Networx lock will function mechanically with its corresponding hardware and will in no way affect the egress at any door. K. Registration of Codes and Credentials/Security Management: 1. All codes and/or credentials for Networx locks shall be recorded by the DL-Windows software-based program specific to the building site. 2. Every code and/or credential issued by the owner shall be entirely unique to that user to whom it is issued. Cards and fobs identified and protected by type and facility code. 3. Wireless networked door access control system will allow for remote door programming and audit trail retrieval and providing all standalone lock functionality plus network-wide global emergency lockdown/unlock commands. Communication is a secure 128bit AES PC encryption and proprietary RF-link lock-to-gateway encryption. 4. System to provide for audit trail of 40,000 events/lock and up to 500 lock/unlock schedules with time zone support HARDWARE

10 5. System to be managed from a single computer utilizing the DL-Windows software 4.1.9X version or higher. 6. Provide construction codes to the contractor during the building s construction period. 7. Construction codes shall self-disable at a specified time and date and shall not require any physical modification of the lock or cylinder. 8. In the event the construction period is longer or shorter than originally planned, locks shall be re-programmable to conform to the schedule change. 9. Wireless locks to be fully keypad programmable. L. Closers: 1. Closers for outswinging exterior doors: Size one size larger than manufacturer's published recommendations, but not less than size Size requirements for other closers: Conform to manufacturer's published recommendations, except as specified otherwise. 3. Operating Pressure: Provide closers with maximum operating pressure as follows: a. Interior Doors: Set closing force on doors accessible to the physically handicapped for a push-pull of 5 pounds applied at knob or handle. b. Exterior Doors: Maximum 8.5 pounds. c. Fire Rated Doors: Set to minimum required to relatch door. M. Protection Plates: 1. Conformance: ANSI A156.6, category J Fabrication. 3. Size: a. Width: 2 inches less in width than door width for single doors and 1 inch less for pairs of doors. b. Height: 1) Armor Plates: 36 inches. 2) Kick Plates: 10 inches except where bottom rail is less than 10 inches, extend plate extend to within 1/2-inch of panel mold or glass bead. 3) Mop Plates: 4 inches. N. Door Edge Guards: 1. Conformance: ANSI A156.6, category J200, non-mortise type. 2. Fabrication: Fabricate from inch thick vinyl, factory adhesive backed with peel off protective paper. O. Miscellaneous: 1. Metal Thresholds: a. Conformance: ANSI A b. Style: shall be as indicated on drawings. c. Where required, modify thresholds to receive projecting bolts of flush bolts and exit devices. d. Thresholds for doors accessible to handicapped: Raised thresholds, corrugated, beveled with slopes not exceeding 1:2, and with height not exceeding 1/2-inch. Bevel not required where height is less than 1/2-inch. P. Accessories: 1. Special Tools: Provide special tools such as spanner and socket wrenches and dogging keys, required to adjust hardware items. Q. Fastenings: 1. Provide proper type, size, quantity, and finish with each article of hardware. 2. Concrete or Grout Filled Masonry: Provide machine screws and expansion shields. 3. Hollow Masonry: Provide resin filled screen anchors equal to Hilti C7 anchors HARDWARE

11 4. Gypsum Wallboard: Provide nylon or derlin expansion anchors equal to Hilti Togglers. 5. Fastenings exposed to weather and in finished work: brass, bronze, or stainless steel. 6. Provide one-way or tamperproof screws on exterior doors equipped with half or full surface hinges. R. Fire Door Hardware: 1. Conform to requirements of NFPA 80 and NFPA 101. S. Finishes: 1. Painting of primed surfaces: Specified in Division 9 - Painting. 2. Plated or Exposed Metal: As indicated in HARDWARE SCHEDULE at end of this Section. T. Keying: 1. Establish a new Factory Key System. 2. Key locks in sets or subsets. 3. Furnish locks with the manufacturer's standard construction cores. 4. Send keys directly from lock manufacturer to Owner by registered mail or other approved means. 5. Supply keys in following quantities: a. 2 keys for each lock. b. 6 master keys. c. 3 grand master keys. d. 3 great grand master keys. e. 6 construction keys. f. 4 control keys. 6. Furnish keys to Owner arranged in a container for key control system storage in sets or subsets as scheduled. PART 3 - EXECUTION 3.1 INSPECTION A. Verify that doors and frames are ready to receive work and dimensions are as indicated on shop drawings. B. Verify that power supply is available to power operated devices. C. Beginning of installation means acceptance of existing conditions. 3.2 INSTALLATION A. General: 1. Locate in accordance with DHI 04 and DHI 05 recommended Locations for Builders' Hardware for Standard Steel Doors and Frames and DHI Recommended Locations for Builders' Hardware for Custom Steel Doors and Frames. 2. Install in accordance with DHI Coordinate mounting height of exit devices with door lites. 4. When approved, slight variations in locations or dimensions will be permitted. 5. Attach door control devices for exterior doors such as closers and holders to doors with thru bolts such as sex bolts and nuts. 6. Conform to 36CFR Part 1191 ANSI A117.1 for positioning requirements for handicapped HARDWARE

12 B. Locks and Latches: 1. Adjust for latching without binding. C. Door-Closing Device: 1. Install and adjust in accordance with templates and printed instructions supplied by manufacturer. 2. Install on solid doors with thru bolts and grommet nuts. 3. Insofar as practicable, mount closers as follows: a. Exterior Doors: Mount closer on interior side of all exterior doors. Provide parallel arms or top jam mount closers. b. Interior Doors: 1) Mount on room side of door for doors opening to or from halls and corridors. 2) Where a door, in the open position, is too close to a wall to prevent the door from opening 90 degrees, or if the closer would hit the wall before contacting the door stop, provide a parallel arm closer. D. Key Control Storage System: 1. Install where directed by Architect. E. Armor, Kick and Mop Plates: 1. Armor Plates: Where scheduled, install on push side of single-acting doors and on both sides of double-acting doors. 2. Kick Plates: Where scheduled, install on push side of single-acting doors and on both sides of double-acting doors. F. Door Edgings: 1. Install on stop face of butt edge of door unless otherwise scheduled. G. Auxiliary Hardware: 1. Install lever extension flush bolts at top and bottom of inactive leaf of pairs of doors. 2. Install dust-proof floor strike or threshold, cut-out for bottom bolt. H. Thresholds: 1. Install in a bed of sealant with stainless steel screws and expansion shields. 2. Provide proper clearance and an effective seal with specified weather stripping. 3. Minimum screw size: #10, length dependent on job conditions. I. Weatherseals: 1. Locate as indicated, snug to door face and fastened in place with color matched metal screws after door and frames have been finish painted. 2. Install to exclude light and air flow when door is in closed position. 3. Screw spacing: as recommended by manufacturer. J. Gasketing: 1. Install at inside edge of hinge, head and latch side of door frame. K. Hardware for Labeled Fire Doors: 1. Install in accordance with requirements of NFPA 80 AND NFPA HARDWARE SCHEDULE Access Control Accessories 3 EA Networx Gateway AL-IMEPOEP...POE connected Alarm Lock 1 EA Netwx Software Windows based v4.0.1 or higher with single database Alarm Lock 1 EA Netwx Proxcards AL-HID per box...prox and photo ID Alarm Lock 1 EA Netwx Training Jobsite visit...training of owner representative Alarm Lock HARDWARE

13 Keying Requirements 0 Key system: Establish new factory key system Sargent 0 EA VKC GMK/MK Keyset + Do Not Duplicate Sargent 0 EA VKC Change Keys Bitting + Do Not Duplicate Sargent 1 EA Bitting list: Shall include present changes Sargent 1 EA Change key: Per lock or exit device over the 2 standard Per lock Sargent 6 EA Masterkeys: MK-?? Sargent 4 EA Control keys: CTRL KEY Sargent 50 EA Keyblanks: keyway on order Sargent 6 EA I/C Core LFIC Sargent 1 EA Key Cabinet {two tag 60 capacity} MMF Industries Hardware Set / Door Number: Gate NOTE: Verify proper function and type during the approval process and prior to ordering. 1 EA Cyl Deadlock cylinder x cylinder 10B Sargent 2 EA I/C Core LFIC Sargent Hardware Set / Door Number: EA Cont Hinge DFM83HD1 TEK...verify with door supplier Duranod Pemko 1 EA Rim Exit Device 8888F B Sargent 1 EA I/C Core LFIC Sargent 1 EA Trilogy Networx ETPDNS1...ETRIC...NS8 26D Alarm Lock 1 EA Drop Plate 1431-D EB Sargent 1 SET Closer accessory blade stop spacer kit for EB Sargent 1 EA Closer/Pa/Stop TB CPS EN Sargent 1 EA Threshold H/C 2005AVK...36"...provide 7/16" door uncut Pemkote Pemko 1 EA Door Btm Sweep 345DV...36" Duranod Pemko Hardware Set / Door Number: EA Passage U15...LL 26D Sargent Hardware Set / Door Number: EA Passage U15...LL 26D Sargent HARDWARE

14 Hardware Set / Door Number: EA Hvy Wt Hinges 4B x D PBB Inc.. 1 EA Rim Exit Device 8888F D Sargent 1 EA Trilogy Networx ETPDNS1...ETRIC...NS8 26D Alarm Lock 1 EA Closer/Parallel TB P10 EN Sargent Hardware Set / Door Number: EA Hvy Wt Hinges 4B x D PBB Inc. 1 PR Pulls BtB RM301-12"...11XHD...engrave one side PUSH 32D Rockwood 42" AFF 1 EA Closer/Standard TB RO EN Sargent Hardware Set / Door Number: EA Hvy Wt Hinges 4B x D PBB Inc. 1 PR Pulls BtB RM301-12"...11XHD...engrave one side PUSH 32D Rockwood 42" AFF 1 EA Closer/Standard TB RO EN Sargent Hardware Set / Door Number: HARDWARE

15 Hardware Set / Door Number: EA Cont Hinge DFM83HD1 TEK...verify with door supplier Duranod Pemko 1 EA Storeroom Lock G04...LL 26D Sargent 1 EA Closer/Pa/Stop TB CPS EN Sargent 1 EA Threshold H/C 2005AV...36"...provide 7/16" door undercut Mill Pemko 1 SET Weatherstrip 45041CNB Clear Pemko 1 SET Header Seal 347A...68AR 40"...ext top of frame & door Mill Pemko 1 EA Door Btm Sweep 345AV...36" Clear Pemko Hardware Set / Door Number: EA I/C Core LFIC Sargent Hardware Set / Door Number: 110 Hardware Set / Door Number: EA Passage U15...LL 26D Sargent Hardware Set / Door Number: EA Hvy Wt Hinges 4B x D PBB Inc. 1 PR Pulls BtB RM301-12"...11XHD...engrave one side PUSH 32D Rockwood 42" AFF 1 EA Closer/Parallel TB P10 EN Sargent HARDWARE

16 Hardware Set / Door Number: EA Hvy Wt Hinges 1 PR Pulls BtB RM301-12"...11XHD...engrave one side PUSH 32D Rockwood 42" AFF 1 EA Closer/Parallel TB P10 EN Sargent Hardware Set / Door Number: EA Hvy Wt Hinges 4B x D PBB Inc. 1 PR Pulls BtB RM301-12"...11XHD...engrave one side PUSH 32D Rockwood 42" AFF 1 EA Closer/Parallel TB P10 EN Sargent Hardware Set / Door Number: EA Hvy Wt Hinges 4B x D PBB Inc. 1 PR Pulls BtB RM301-12"...11XHD...engrave one side PUSH 32D Rockwood 42" AFF 1 EA Closer/Parallel TB P10 EN Sargent Hardware Set / Door Number: EA Hvy Wt Hinges 4B x D PBB Inc. 1 PR Pulls BtB RM301-12"...11XHD...engrave one side PUSH 32D Rockwood 42" AFF 1 EA Closer/Parallel TB P10 EN Sargent HARDWARE

17 Hardware Set / Door Number: 118 Hardware Set / Door Number: 119 Hardware Set / Door Number: 120 Hardware Set / Door Number: EA EA Hinges Office Lock BB x G05...LL 26D 26D PBB Inc. Sargent Hardware Set / Door Number: HARDWARE

18 Hardware Set / Door Number: EA Hvy Wt Hinges 4B x D PBB Inc. 1 EA Closer/Standard TB RO EN Sargent Hardware Set / Door Number: EA Cont Hinge DFM83HD1 TEK...verify with door supplier Duranod Pemko 1 EA Rim Exit Device 8888F D Sargent 1 EA Trilogy Networx ETPDNS1...ETRIC...NS8 26D Alarm Lock 1 EA Closer/Parallel TB P10 EN Sargent 1 EA Threshold H/C 2005AV..36"...provide 7/16" door undercut Mill Pemko 1 SET Weatherstrip 45041CNB Clear Pemko 1 EA Door Btm Sweep 345AV..36" Clear Pemko Hardware Set / Door Number: 125 Hardware Set / Door Number: HARDWARE

19 Hardware Set / Door Number: 127 Hardware Set / Door Number: EA Hvy Wt Hinges 4B x D PBB Inc. 2 PR Pulls BtB RM301-12"...11XHD...engrave one side PUSH 32D Rockwood 42" AFF 1 EA Closer/Parallel TB P10 EN Sargent RHR door 1 EA Closer/Pa/Stop TB CPS EN Sargent LHR door RHR door 2 EA Silencers metal frames Gray Rockwood Hardware Set / Door Number: 129A 1 EA Cont Hinge DFM83HD1..TEK...verify with door supplier Duranod Pemko 1 EA Rim Exit Device 8888F D Sargent 1 EA Trilogy Networx ETPDNS1...ETRIC...NS8 26D Alarm Lock 1 EA Closer/Pa/Stop TB CPS EN Sargent 1 EA Threshold H/C 2005AV..36"...provide 7/16" door undercut Mill Pemko 1 SET Weatherstrip 45041CNB Clear Pemko 1 EA Door Btm Sweep 345AV..36" Clear Pemko Hardware Set / Door Number: 130 NOTE: All hardware provided by overhead door supplier HARDWARE

20 Hardware Set / Door Number: EA Hvy Wt Hinges 4B x D PBB Inc. 1 PR Pulls BtB RM301-12"...11XHD...engrave one side PUSH 32D Rockwood 42" AFF 1 EA Closer/Standard TB RO EN Sargent Hardware Set / Door Number: 131A 3 EA Hvy Wt Hinges 4B x D PBB Inc. 1 PR Pulls BtB RM301-12"...11XHD...engrave one side PUSH 32D Rockwood 42" AFF 1 EA Closer/Parallel TB P10 EN Sargent Hardware Set / Door Number: EA Hvy Wt Hinges 4B x D PBB Inc. 1 EA Flushbolts "...labeled steel doors 26D Rockwood 1 EA Dustproof Strik D Rockwood 1 EA Classroom Lock G37...LL...1" strike lip 26D Sargent RHR door 2 EA Closer/Pa/Stop TB CPS EN Sargent 2 EA Kickplate 8"h x 34"w x.040 vinyl TBD IPC 2 EA Silencers metal frames Gray Rockwood Hardware Set / Door Number: 133 NOTE: All hardware provided by overhead door supplier. Hardware Set / Door Number: 133A NOTE: All hardware provided by overhead door supplier. Hardware Set / Door Number: 133B NOTE: All hardware provided by overhead door supplier. Hardware Set / Door Number: 133C NOTE: All hardware provided by overhead door supplier HARDWARE

21 Hardware Set / Door Number: 133D NOTE: All hardware provided by overhead door supplier. Hardware Set / Door Number: 133E NOTE: All hardware provided by overhead door supplier. Hardware Set / Door Number: 133F NOTE: Reuse existing hardware. Hardware Set / Door Number: 134 NOTE: All hardware provided by overhead door supplier. Hardware Set / Door Number: 134A NOTE: All hardware provided by overhead door supplier. Hardware Set / Door Number: 134B 1 EA Cont Hinge DFM83HD1..TEK...verify with door supplier Duranod Pemko 1 EA Rim Exit Device 8888F D Sargent 1 1 EA EA Trilogy Networx Closer/Pa/Stop ETPDNS1...ETRIC...NS8 TB CPS 26D EN Alarm Lock Sargent 1 EA Threshold H/C 2005AV..36"...provide 7/16" door undercut Mill Pemko 1 SET Weatherstrip 45041CNB Clear Pemko 1 3 EA EA Door Btm Sweep Silencers 345AV..36" metal frames Clear Gray Pemko Rockwood END OF SECTION HARDWARE

Alarm Lock A Division of the Napco Security Group 333 Bayview Avenue Amityville, New York Phone (631) Fax (631)

Alarm Lock A Division of the Napco Security Group 333 Bayview Avenue Amityville, New York Phone (631) Fax (631) Alarm Lock ArchiTech Series Lockset Specification Alarm Lock A Division of the Napco Security Group 333 Bayview Avenue Amityville, New York 11701 Phone (631) 842-9400 Fax (631) 789-3383 http://www.alarmlock.com

More information

FROM: PARKHILL, SMITH, & COOPER, INC. PROJECT NAME: BORGER XCEL BUILDING AND

FROM: PARKHILL, SMITH, & COOPER, INC. PROJECT NAME: BORGER XCEL BUILDING AND 4 85th Street Lubbock, Texas 7943 806.473.00 ADDENDUM NO: 01 TO: ALL PLANHOLDERS FROM: PARKHILL, SMITH, & COOPER, INC. PROJECT NAME: BORGER XCEL BUILDING AND PROJECT NO.: 03.7787.14 DATE: 07//015 07//15

More information

1. Items known commercially as finish hardware or builders hardware, required for swing, sliding, or folding doors.

1. Items known commercially as finish hardware or builders hardware, required for swing, sliding, or folding doors. PART 1 - GENERAL 1.1 SUMMARY: A. Section Includes: SECTION 08710 FINISH HARDWARE 1. Items known commercially as finish hardware or builders hardware, required for swing, sliding, or folding doors. 2. Types

More information

University of Rochester October 17, 2008 Brooks Landing Business Center

University of Rochester October 17, 2008 Brooks Landing Business Center SECTION 087100 - DOOR HARDWARE PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following: 1. Commercial door hardware. 2. Cylinders for doors specified in other Sections. 1.2 SUBMITTALS A. Product

More information

C. Thresholds, weatherstripping, seals and door gaskets. A. ANSI/ICC A117.1 Standard for Accessibility and Usable Buildings and Facilities; 1998

C. Thresholds, weatherstripping, seals and door gaskets. A. ANSI/ICC A117.1 Standard for Accessibility and Usable Buildings and Facilities; 1998 SECTION 08 71 00 - Page 1 PART 1 GENERAL 1.1 SECTION INCLUDES A. Hardware for steel doors. B. Electrified door hardware. C. Thresholds, weatherstripping, seals and door gaskets. 1.2 RELATED SECTIONS A.

More information

SECTION DOOR HARDWARE

SECTION DOOR HARDWARE McClellan Blakemore Architects New Warehouse Facility for SECTION 08710 DOOR HARDWARE PART 1 GENERAL 1.01 SECTION INCLUDES A. Hardware for wood and hollow steel doors. B. Hardware for fire-rated doors.

More information

UNIVERSITY OF ROCHESTER DESIGN STANDARDS FEBRUARY 2005MARCH 2007

UNIVERSITY OF ROCHESTER DESIGN STANDARDS FEBRUARY 2005MARCH 2007 SECTION 08710 - DOOR HARDWARE 1.1 SUMMARY A. Door hardware required for swinging doors. No pocket or folding doors permitted at U of R. 1.2 SUBMITTALS A. Hardware Schedule: To be coordinated with doors,

More information

SECTION DOOR HARDWARE

SECTION DOOR HARDWARE PART 1 GENERAL 1.01 SECTION INCLUDES SECTION 08 7100 DOOR HARDWARE A. Hardware for wood, aluminum, and hollow metal doors. B. Hardware for fire-rated doors. C. Electrically operated and controlled hardware.

More information

SEQUOYAH SCHOOLS FI&R 06 G01 Cherokee Nation Tahlequah, Oklahoma

SEQUOYAH SCHOOLS FI&R 06 G01 Cherokee Nation Tahlequah, Oklahoma Eastern Oklahoma Tribal Schools Facilities Management Program Choctaw Nation of Oklahoma 601 North Kelly Avenue, Suite 105 Edmond, Oklahoma 73003 Voice: (405) 330 9236 Fax: (405) 330 9261 Serving the schools

More information

ONONDAGA COMMUNITY COLLEGE FERRANTE HALL RENOVATIONS - PHASE

ONONDAGA COMMUNITY COLLEGE FERRANTE HALL RENOVATIONS - PHASE SECTION 08 71 00 - DOOR HARDWARE PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

HALIFAX HUMANE SOCIETY ADDITIONS AND ALTERATIONS. B. See Division 08 door sections for astragals and door silencers.

HALIFAX HUMANE SOCIETY ADDITIONS AND ALTERATIONS. B. See Division 08 door sections for astragals and door silencers. SECTION 087100 - DOOR HARDWARE PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following: 1. Commercial door hardware. 2. Cylinders for doors specified in other Sections. B. See Division 08 door

More information

B. Shop Drawings: Details of electrified door hardware, including wiring diagrams.

B. Shop Drawings: Details of electrified door hardware, including wiring diagrams. SECTION 087100 - PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following: 1. Commercial door hardware for the following: a. Swinging doors. b. Other doors to the extent indicated. B. Related

More information

DSC BUILDING 1200 ALTERATIONS OCTOBER 2011

DSC BUILDING 1200 ALTERATIONS OCTOBER 2011 SECTION 087100 - DOOR HARDWARE PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following: 1. Commercial door hardware. 1.2 SUBMITTALS A. Product Data: For each type of product indicated. B. Other

More information

Architect s Specification Guideline:

Architect s Specification Guideline: Architect s Specification Guideline: Hollow Metal Section 08 11 00 Wood Door Section 08 14 00 Aluminum Door/Frame Section 08 11 16 Door Hardware Section 08 71 00 The University of Texas at Dallas Richardson,

More information

DIVISION 08 OPENINGS HARDWARE AND KEYING PART 1 - GENERAL 1.01 SUMMARY

DIVISION 08 OPENINGS HARDWARE AND KEYING PART 1 - GENERAL 1.01 SUMMARY 08 70 00 PART 1 - GENERAL 1.01 SUMMARY A. Section includes the design and coordination for all necessary hardware and coordination for all doors. Hardware shall include but not necessarily be limited to

More information

DIVISION 08 OPENINGS HARDWARE AND KEYING PART 1 - GENERAL 1.01 SUMMARY

DIVISION 08 OPENINGS HARDWARE AND KEYING PART 1 - GENERAL 1.01 SUMMARY 08 70 00 PART 1 - GENERAL 1.01 SUMMARY A. Section includes the design and coordination for all necessary hardware and coordination for all doors. Hardware shall include but not necessarily be limited to

More information

SECTION FINISH HARDWARE

SECTION FINISH HARDWARE SECTION 08710 FINISH HARDWARE PART I GENERAL 1.01 SUMMARY A. SECTION INCLUDES 1. The work in this section includes furnishing all items of finish hardware as hereinafter specified or obviously necessary

More information

DOOR HARDWARE SECTION DESIGN REQUIREMENTS GENERAL INFORMATION

DOOR HARDWARE SECTION DESIGN REQUIREMENTS GENERAL INFORMATION DOOR HARDWARE GENERAL INFORMATION 1.1 CU Morningside, Manhattanville, Nevis and Lamont Dougherty Campus have specific hardware requirements. Standardized door hardware, systems, and components are described

More information

SECTION DOOR HARDWARE

SECTION DOOR HARDWARE PART 1 GENERAL 1.01 SUMMARY A. Section Includes SECTION 08 7100 DOOR HARDWARE The work in this section includes furnishing and installing all items of architectural hardware for aluminum, wood and hollow

More information

ADDENDUM - 01 REGAN YOUNG ENGLAND BUTERA

ADDENDUM - 01 REGAN YOUNG ENGLAND BUTERA ADDENDUM - 01 REGAN YOUNG ENGLAND BUTERA REFERENDUMS ENGINEERING ARCHITECTURE DESIGN 456 HIGH ST. MT. HOLLY, NJ 08060 USA DATE:... Tuesday, 19 March 2019 FROM:...Angelo P. Butera, AIA VIA:... Facsimile

More information

UBC Technical Guidelines Section Edition Door Hardware Page 1 of 7

UBC Technical Guidelines Section Edition Door Hardware Page 1 of 7 Page 1 of 7 1.0 GENERAL 1.1 Related UBC Guidelines.1 Division 26.2 Division 28.3 Section 08 00 10 Openings General Requirements.4 Section 28 05 00 Common Work Results for Electronic Safety and Security.5

More information

2. Interior doors shall be not less than 18 gauge steel.

2. Interior doors shall be not less than 18 gauge steel. DIVISION 8 - DOORS AND WINDOWS 08100 METAL DOORS AND FRAMES 1. Exterior doors shall be not less than 16 gauge steel. The top channel of each metal door shall be solid without pockets which collect dirt

More information

Lake County / Multi-Department Storage Facility / Project / December 05, 2016 SECTION DOOR HARDWARE

Lake County / Multi-Department Storage Facility / Project / December 05, 2016 SECTION DOOR HARDWARE PART 1 - GENERAL SECTION 087100 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections, apply to

More information

SECTION DOOR HARDWARE

SECTION DOOR HARDWARE SECTION 08 71 00 - DOOR HARDWARE PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General Conditions, Division 1 - GENERAL REQUIREMENTS, and other applicable

More information

SECTION INTEGRATED DOOR ASSEMBLIES

SECTION INTEGRATED DOOR ASSEMBLIES SECTION 08 17 10 INTEG DOOR ASSEMBLIES SPEC WRITER NOTE: Delete text between // // not applicable to project. Edit remaining text to suit project. PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Integrated

More information

APPENDIX F: LOCKSETS AND ACCESS CONTROL

APPENDIX F: LOCKSETS AND ACCESS CONTROL APPENDIX F: LOCKSETS AND ACCESS CONTROL F.1 LOCKSETS The University, with the exception of the Housing Division which uses a Best 7-pin system, utilizes a Corbin Russwin 7-pin IC Core keying system. Locksets

More information

SECTION DOOR HARDWARE HSC Guide Specification for Capital Construction. [Adjust to Suit Project]

SECTION DOOR HARDWARE HSC Guide Specification for Capital Construction. [Adjust to Suit Project] SECTION 08 71 00 DOOR HARDWARE HSC Guide Specification for Capital Construction [Adjust to Suit Project] PART 4 - GENERAL 4.1 GENERAL REQUIREMENTS A. Drawings and general provisions of the Contract, including

More information

FINISH HARDWARE FOR ADDITIONS, RENOVATIONS, AND REMODELINGS. A. Provide finish hardware including necessary accessories.

FINISH HARDWARE FOR ADDITIONS, RENOVATIONS, AND REMODELINGS. A. Provide finish hardware including necessary accessories. SECTION 08711 FINISH HARDWARE FOR ADDITIONS, RENOVATIONS, AND REMODELINGS PART 1 GENERAL 1.01 SUMMARY A. Provide finish hardware including necessary accessories. B. Related Sections: 1. 06100 - Carpentry.

More information

Title Page Table of Contents Instruction to Bidders Form of Proposal Equal Opportunity Statement Form of Guarantee Supplemental General Conditions

Title Page Table of Contents Instruction to Bidders Form of Proposal Equal Opportunity Statement Form of Guarantee Supplemental General Conditions P00000000 0000 DOCUMENTS SPECIFICATION DIVISION 8 NUMBER SECTION DESCRIPTION DIVISION 08 DOOR AND WINDOWS SECTION 08710 - DOOR HARDWARE Title Page Table of Contents Instruction to Bidders Form of Proposal

More information

SECTION &.40 DOOR HARDWARE

SECTION &.40 DOOR HARDWARE SECTION 08 71 00.10 &.40 DOOR HARDWARE PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

v.3.1: December 19, 2014

v.3.1: December 19, 2014 SECTION 08 71 00 DOOR HARDWARE PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Door hardware for aluminum, metal and wood doors. 2. Thresholds, weather-stripping, coordinators, astragals and door

More information

THE LEDGE AT CABOT DRIVE. NASHVILLE, TN

THE LEDGE AT CABOT DRIVE. NASHVILLE, TN SECTION 087100 DOOR HARDWARE PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections,

More information

SECTION DOOR HARDWARE

SECTION DOOR HARDWARE SECTION 08711 DOOR HARDWARE PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following: 1. Commercial door hardware. 2. Cylinders for doors specified in other Sections. 3. Electrified door hardware.

More information

Product Catalog. 8X Line Cylindrical Knob Locks

Product Catalog. 8X Line Cylindrical Knob Locks Product Catalog 8X Line Cylindrical Knob Locks XX Features and Benefits...3 Functions, Knob and Rose Design... 4 Latches and Strikes...5 Mechanical Options and Cylinder Options...6 How to Order, Finishes/Packaging

More information

Job No. EGOS

Job No. EGOS SECTION 087100 DOOR HARDWARE PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

DOOR HARDWARE

DOOR HARDWARE SECTION 08 7100 DOOR HARDWARE PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division 1 Specification Sections,

More information

About the Instructor & Presenter:

About the Instructor & Presenter: About the Instructor & Presenter: Paul G. Baillargeon, AHC, FDAI Vice President, Technical Consulting Door Security & Safety Foundation A noted veteran in the door and hardware industry, Mr. Baillargeon

More information

New Bedford, Massachusetts Tel: (617) CBI Job No.: Fax: (617)

New Bedford, Massachusetts Tel: (617) CBI Job No.: Fax: (617) SECTION 08 71 00 PART 1 - GENERAL 1.01 GENERAL REQUIREMENTS A. Include the General Conditions, Modifications to the General Conditions, and applicable parts of Division 01 as part of this Section. B. Examine

More information

BuildingName The Description of the Project P DOCUMENTS

BuildingName The Description of the Project P DOCUMENTS ARCHITECTURE, ENGINEERING AND CONSTRUCTION P00000000 0000 DOCUMENTS ARCHITECTURE & ENGINEERING 326 East Hoover, Mail Stop B Ann Arbor, MI 48109-1002 Phone: 734-764-3414 Fax: 734-936-3334 SPECIFICATION

More information

ABLOY EFEND. New name for security

ABLOY EFEND. New name for security ABLOY EFEND New name for security SET SECURITY TO NEXT LEVEL ABLOY is now available in ANSI door environment. OPTIONS FOR EVERY NEED Inclusive product range includes both electric and mechanical locking

More information

SECTION DOOR HARDWARE HSC Guide Specification for Capital Construction. [Adjust to Suit Project and Confirm with University Lock Shop]

SECTION DOOR HARDWARE HSC Guide Specification for Capital Construction. [Adjust to Suit Project and Confirm with University Lock Shop] SECTION 08 71 02 DOOR HARDWARE HSC Guide Specification for Capital Construction [Adjust to Suit Project and Confirm with University Lock Shop] PART 1 - GENERAL 1.1 GENERAL REQUIREMENTS A. Drawings and

More information

Cylindrical Lever Lock

Cylindrical Lever Lock 6500 Cylindrical Lever Lock Copyright 2004-2009, 2011-2015, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Specifications 65G05 Shown KL Design Rose: K Wrought Lever:

More information

STC 46 3-Sided Paired Frame (Double Rabbet Only)

STC 46 3-Sided Paired Frame (Double Rabbet Only) (Toll Free) Phone 866-452-1845 Fax 910-452-1848 STC 46 3-Sided Paired Frame (Double Rabbet Only) FRAME PART DIMENSIONS E E THROAT THROAT MINIMUM 3 5/16" MAXIMUM 13" D A=Jamb Depth MINIMUM 4 5/16" MAXIMUM

More information

6 Line Knob. Table of Contents. Specifications. MicroShield Coating. Certification Compliance. On the Cover

6 Line Knob. Table of Contents. Specifications. MicroShield Coating. Certification Compliance. On the Cover Bored Copyright 2003, 2004, 2007, 2008, 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Table of Contents Features & Benefits..................................................

More information

SECTION HARDWARE

SECTION HARDWARE SECTION 08 70 00 - HARDWARE Refer to each numbered building file (request from Project Manager) and the University's Facilities Management Lockshop. Hardware: 1. Locksets a. Locksets shall be provided

More information

Bored Lock. SARGENT Manufacturing Company 2003, 2004, 2007 All rights reserved

Bored Lock. SARGENT Manufacturing Company 2003, 2004, 2007 All rights reserved Bored SARGENT Manufacturing Company 2003, 2004, 2007 All rights reserved Table of Contents Features & Benefits.................................................. 1 & Rose Designs.................................................

More information

An ASSA ABLOY Group brand Series. Grade 2 Cylindrical Knob Locks

An ASSA ABLOY Group brand Series. Grade 2 Cylindrical Knob Locks An ASSA ABLOY Group brand 5300 Series Grade 2 Cylindrical Knob Locks Page Revised Electronically 4/11, 8/11 5300 series cylindrical knob locks built to last Yale 5300 series standard-duty cylindrical locksets

More information

DIVISION 10 SPECIALTIES

DIVISION 10 SPECIALTIES DIVISION 10 SPECIALTIES 11/11 SECTION 10 21 13.16 PLASTIC LAMINATE TOILET COMPARTMENTS PART 1 - GENERAL 1.01 SECTION INCLUDES Plastic laminate toilet compartments, urinal screens, head rail braced. 1.02

More information

A. AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA) 101: Appendix Dissimilar Materials.

A. AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA) 101: Appendix Dissimilar Materials. B B11.0 DIVISION 08 - OPENINGS SECTION 08 17 00 INTEGRATED DOOR OPENING ASSEMBLIES Specifier Note: Coordinate and edit articles and paragraphs below to suit project requirements. Add section numbers and

More information

1. Commercial door hardware for the following: a. Swinging doors. b. Other doors to the extent indicated.

1. Commercial door hardware for the following: a. Swinging doors. b. Other doors to the extent indicated. SECTION 087100 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply

More information

SECTION AUTOMATIC TRANSFER SWITCHES

SECTION AUTOMATIC TRANSFER SWITCHES PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 36 23 SPEC WRITER NOTE: Use this section only for NCA projects. Delete between //--// if not applicable to project. Also, delete any other item or paragraph

More information

Table of Contents Auxiliary Locks

Table of Contents Auxiliary Locks Copyright 2007-2018, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company

More information

An ASSA ABLOY Group brand. 4300LN Series. Grade 2 Tubular Lever Locks

An ASSA ABLOY Group brand. 4300LN Series. Grade 2 Tubular Lever Locks An ASSA ABLOY Group brand 4300LN Series Grade 2 Tubular Lever Locks the engineer's choice introduction An economical, light/medium duty Grade 2 lever lockset which provides an outstanding combination of

More information

Architectural Specification Sheet

Architectural Specification Sheet Architectural Specification Sheet 1. General 1.01 Summary A. commercial low energy automatic swing door operator that consists of: -Aluminum housing -Electro-mechanical motor -Operator control assembly

More information

Fire Rated Door Assemblies: Compliant Designs

Fire Rated Door Assemblies: Compliant Designs Fire Rated Door Assemblies: Compliant Designs Steel Door Institute www.steeldoor.org AIA Provider #G389 Course #: SDIFIRE 1 HSW CE hour 1 Credit(s) earned on completion of this course will be reported

More information

CK4300 Series. Cylindrical Knob Locksets

CK4300 Series. Cylindrical Knob Locksets Series Cylindrical Knob Locksets Applications Table of Contents Applications... 2 Features... 3 Functions... 4 Trim Designs... 5 Options and Accessories... 6 How to Order... 8 Quick Codes... 9 How to Specify...

More information

ARCHITECTURAL SPECIFICATIONS

ARCHITECTURAL SPECIFICATIONS 1 B9.1 In Ground Page 1 of 6, Aug 12 DIVISION 08 - OPENINGS SECTION 08 71 13 POWER DOOR OPERATORS Specifier Note: Coordinate and edit articles and paragraphs below to suit project requirements. Add section

More information

Alarmed Exit Hardware

Alarmed Exit Hardware Copyright 2005, 2007, 2009-2016, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Contents 540/550 Series Exit Alarm...1 5100 Series Alarmed Exit Lock...2 5800 & 12-5800

More information

2409/2900. Fire Guard

2409/2900. Fire Guard 2409/2900 Fire Guard Table of Contents Features and Additional Fire Opening Devices... 1 2409 Single-Point Hold Open Applications and Mounting Details... 2 2409 Track Assemblies, Arms and Components...

More information

An ASSA ABLOY Group brand. 4800LN Series. Interconnected Locks

An ASSA ABLOY Group brand. 4800LN Series. Interconnected Locks An ASSA ABLOY Group brand 4800LN Series Interconnected Locks Page Revised Electronically 4/11 4800LN series interconnected lockset performance meets style introduction The Yale 4800LN series interconnected

More information

SECTION DOOR HARDWARE

SECTION DOOR HARDWARE SECTION 08710 DOOR HARDWARE Montgomery County Public Schools Facilities Guide DIVISION 8 DOORS AND WINDOWS PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including

More information

SECTION P01 LIGHTING AND APPLIANCE PANELBOARDS - A-SERIES

SECTION P01 LIGHTING AND APPLIANCE PANELBOARDS - A-SERIES PART 1 GENERAL A. The requirements of the Contract, Division 1, and Division 16 apply to work in this Section. 1.01 SECTION INCLUDES A. Lighting and appliance panelboards 1.02 RELATED SECTIONS A. 16475,

More information

SPECIFICATION SECTION : FIRE RATED GLASS & FRAMING GPX Builders Series Fire Protective

SPECIFICATION SECTION : FIRE RATED GLASS & FRAMING GPX Builders Series Fire Protective Welcome to the SAFTIFIRST TM Guide Specification System prepared as an aid to specifiers in preparing written construction documents. For specification assistance with specific product applications, please

More information

PROJECT NO. CWA SEPTEMBER 24, 2014 ADDENDUM NO. 6 BESSEMER RECREATION & WELLNESS CENTER

PROJECT NO. CWA SEPTEMBER 24, 2014 ADDENDUM NO. 6 BESSEMER RECREATION & WELLNESS CENTER PROJECT NO. CWA 2013-04 SEPTEMBER 24, 2014 ADDENDUM NO. 6 BESSEMER RECREATION & WELLNESS CENTER BIDS RECEIVED: CITY HALL, CITY OF BESSEMER TIME: 2:00pm DATE: October 2, 2014 City of Bessemer --------------------------------------------------------------------------------------------------------------------------------------------

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-08 71 00 (February 2016) Change 1-11/17 ----------------------------- Preparing Activity: NAVFAC Superseding UFGS-08 71 00 (August 2008) UNIFIED FACILITIES GUIDE SPECIFICATIONS

More information

Laura Frye, AHC, CSI, CCS, FDAI Technical Director, DSSF Director of Certification, DHI

Laura Frye, AHC, CSI, CCS, FDAI Technical Director, DSSF Director of Certification, DHI Laura Frye, AHC, CSI, CCS, FDAI Technical Director, DSSF Director of Certification, DHI Inspecting Swinging Fire Doors with Builders Hardware A Practical Guide for AHJs and Facility Management Personnel

More information

Specifications 7 Line Cylindrical Lever Locks

Specifications 7 Line Cylindrical Lever Locks 7 Line Bored Lever Lock Copyright 2003-2014, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Specifications Table of Contents Windstorm Certifications...1 Features, Benefits

More information

DETEX ARCHITECTURAL SPECIFICATIONS, June 2012 AO19 SERIES HEAVY DUTY LOW-ENERGY ELECTRIC SWING DOOR OPERATOR

DETEX ARCHITECTURAL SPECIFICATIONS, June 2012 AO19 SERIES HEAVY DUTY LOW-ENERGY ELECTRIC SWING DOOR OPERATOR DETEX ARCHITECTURAL SPECIFICATIONS, June 2012 AO19 SERIES HEAVY DUTY LOW-ENERGY ELECTRIC SWING DOOR OPERATOR SECTION 08 71 13 LOW ENERGY AUTOMATIC OPERATORS Specifier Note: Coordinate and edit articles

More information

SPECIFICATION SECTION : FIRE RATED GLASS & FRAMING GPX Builders Series Temperature Rise Door Framing

SPECIFICATION SECTION : FIRE RATED GLASS & FRAMING GPX Builders Series Temperature Rise Door Framing Welcome to the SAFTIFIRST TM Guide Specification System prepared as an aid to specifiers in preparing written construction documents. For specification assistance with specific product applications, please

More information

An ASSA ABLOY Group brand Series. Grade 1 Cylindrical Knob Locks

An ASSA ABLOY Group brand Series. Grade 1 Cylindrical Knob Locks An ASSA ABLOY Group brand 5400 Series Grade 1 Cylindrical Knob Locks time-tested quality introduction When demanding the highest standard of product performance in even the toughest industrial applications,

More information

SECTION DOOR HARDWARE

SECTION DOOR HARDWARE SECTION 08710 DOOR HARDWARE Montgomery County Public Schools Facilities Guide DIVISION 8 DOORS AND WINDOWS PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including

More information

SPECIFICATION SECTION : FIRE RATED GLASS & FRAMING GPX Builders Series Fire Protective

SPECIFICATION SECTION : FIRE RATED GLASS & FRAMING GPX Builders Series Fire Protective Welcome to the SAFTIFIRST TM Guide Specification System prepared as an aid to specifiers in preparing written construction documents. For specification assistance with specific product applications, please

More information

8/9 Line. Bored Knob Locks

8/9 Line. Bored Knob Locks 8/9 Line Bored Knob Locks Copyright 2002, 2004, 2007, 2009, 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Table of Contents Features & Benefits... 1 Knob & Rose

More information

2408/2900. Fire Guard

2408/2900. Fire Guard 2408/2900 Fire Guard Table of Contents Features and Additional Fire Opening Devices... 1 2408 Single-Point Hold Open Applications and Mounting Details... 2 2408 Track Assemblies, Arms and Components...

More information

ED3000 Series. Crossbar Exit Devices

ED3000 Series. Crossbar Exit Devices Crossbar Exit Devices Introduction Table of Contents Applications and Listings... 3 Functions... 4 Rim Exit Features... 5 Surface Vertical Rod Exit Features... 7 Mortise Exit Features... 9 Trims and Functions...

More information

Overview, Features and Electrical Specifications Harmony Series

Overview, Features and Electrical Specifications Harmony Series Overview, Features and Electrical Specifications Overview The patented* combines a card reader, Door Position Switch (DPS), and Request-to-Exit (REX) signaling in a sleek, pleasing design backed by SARGENT

More information

Glass Solutions Sweets Brochure

Glass Solutions Sweets Brochure Glass Solutions Sweets Brochure About ASSA ABLOY ASSA ABLOY is the global leader in door opening solutions, representing door and hardware brands. Our goal is to help facilities improve all aspects of

More information

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES SECTION 8710 DOOR HARDWARE PART 1DESIGN DIRECTIVES 1.1GENERAL A.The purpose of this section is to insure the continuing high standard of finish hardware for all Dartmouth buildings and to ensure system

More information

COMBINED CONTRACT Nov. 10, NOTICE TO BIDDERS: Amend the Project Manual and Drawings to the above referenced project as follows: PROJECT MANUAL

COMBINED CONTRACT Nov. 10, NOTICE TO BIDDERS: Amend the Project Manual and Drawings to the above referenced project as follows: PROJECT MANUAL ADDENDUM NO. CC-1 STATE OF NEBRASKA 501 BUILDING RENOVATION DATA CENTER RENOVATION & BRASKA DLR GROUP PROJECT NO. 10-16206-00 Architecture Engineering Planning Interiors 6457 Frances Street, Suite 200

More information

Feb H: FINISH HARDWARE

Feb H: FINISH HARDWARE 2101 Commonwealth Blvd, Suite B Ann Arbor, MI 48105-5759 www.med.umich.edu/facilities/plan/ 087100-H: FINISH HARDWARE GENERAL In general, follow the guidelines below when designing and specifying finish

More information

NFPA 80 Overview January 21, 2016

NFPA 80 Overview January 21, 2016 NFPA 80 Overview January 21, 2016 Kristin Bigda, P.E. Senior Fire Protection Engineer National Fire Protection Association Presenter Kristin Bigda, P.E. Senior Fire Protection Engineer, NFPA Building Fire

More information

CL3800 Series. Standard-Duty Key-in-Lever Locksets

CL3800 Series. Standard-Duty Key-in-Lever Locksets Series Standard-Duty Key-in-Lever Locksets Applications Index Applications... 2 Features... 3 Functions... 4-6 Trim Designs... 7 An economical, Grade 2 standard-duty lever lockset which provides an outstanding

More information

4300LN Series Grade 2 Tubular Lever Locks. An ASSA ABLOY Group brand

4300LN Series Grade 2 Tubular Lever Locks. An ASSA ABLOY Group brand 4300LN Series Grade 2 Tubular Lever Locks An ASSA ABLOY Group brand the engineer's choice introduction An economical, light/medium duty Grade 2 lever lockset which provides an outstanding combination of

More information

FLUSHBOLT - WITHOUT ASTRAGAL (Example: Wide Inactive Leaf) DOOR HARDWARE PREPARATIONS

FLUSHBOLT - WITHOUT ASTRAGAL (Example: Wide Inactive Leaf) DOOR HARDWARE PREPARATIONS FLUSHBOLT - WITHOUT ASTRAGAL (Example: Wide Inactive Leaf) Preparation for flushbolts and strikes in inactive leaves (See Note 3) 6-3/4 9 (See Note 2) 1 Flushbolt Elevation Detail Flushbolt Prep Detail

More information

1800 Series Flatbar Exit Devices

1800 Series Flatbar Exit Devices 1800 Series Flatbar Exit Devices Table of Contents CONTENTS Introduction... 3 Benefits & Features... 4 Finishes... 5 How to Order... 6 1800(F) Rim.... 7 1810(F) Surface Vertical Rod.... 8 Trim Designs...9-12

More information

B. Product Data: Provide manufacturers catalogue information. Indicate valve data and ratings.

B. Product Data: Provide manufacturers catalogue information. Indicate valve data and ratings. DIVISION 21 21 05 00 COMMON WORK RESULTS FOR FIRE SUPPRESSION PART 1 GENERAL 1.1 SECTION INCLUDES A. Pipe, fittings, sleeves, escutcheons, seals, and connections for sprinkler systems. 1.2 RELATED REQUIREMENTS

More information

Become a Door Security. Solutions Expert

Become a Door Security. Solutions Expert Become a Door Security Solutions Expert Insights Beyond the Product For those in search of best practices on protecting the people and places most critical to their customers, ASSA ABLOY Academy is a vital

More information

2408/2900. Fire Guard. SARGENT Manufacturing Company 2004, 2007 All rights reserved

2408/2900. Fire Guard. SARGENT Manufacturing Company 2004, 2007 All rights reserved Fire Guard SARGENT Manufacturing Company 2004, 2007 All rights reserved Fire Guard Table of Contents Features and Additional Fire Opening Devices............................1 2408 Single-Point Hold Open

More information

ALARMED EXIT HARDWARE

ALARMED EXIT HARDWARE ALARMED EXIT HARDWARE Table of Contents 540/550 Series Exit Alarms.............................................1 5100 Series Alarmed Exit Lock..........................................2 5800 & 12-5800

More information

April 2, 2019 ADDENDUM NO. 3 DEPARTMENT OF PUBLIC WORKS OPERATIONS BUILDING

April 2, 2019 ADDENDUM NO. 3 DEPARTMENT OF PUBLIC WORKS OPERATIONS BUILDING April 2, 2019 ADDENDUM NO. 3 DEPARTMENT OF PUBLIC WORKS OPERATIONS BUILDING Notice is hereby given that the following additional information and changes shall become part of the specifications of the above

More information

DIVISION 8 OPENINGS SECTION OVERHEAD COILING FIRE DOORS. A. Section Metal Fabrications: Support framing and framed opening.

DIVISION 8 OPENINGS SECTION OVERHEAD COILING FIRE DOORS. A. Section Metal Fabrications: Support framing and framed opening. DIVISION 8 OPENINGS SECTION 08 33 23 PART 1 GENERAL 1.1 SECTION INCLUDES A. Overhead coiling counter fire doors. 1.2 RELATED SECTIONS A. Section 05500 - Metal Fabrications: Support framing and framed opening.

More information

EntryCheck E70 Series

EntryCheck E70 Series EntryCheck E70 Series Standalone Electronic Locksets The EntryCheck E70 Series is an indoor/outdoor standalone electronic battery powered solution, providing controlled access for basic and multi-level

More information

Swinging Egress and Fire Doors

Swinging Egress and Fire Doors Presented by: AHCA Seminar: Inspecting and Maintaining Swinging Egress and Fire Doors Current State CMS Memorandum July 28, 2017 Tuesday May, 3, 2016 CMS issued the final rule adopting the 2012 Life Safety

More information

10 LINE CYLINDRICAL LEVER LOCKS SARGENT Manufacturing Company 2006, 2007 All rights reserved

10 LINE CYLINDRICAL LEVER LOCKS SARGENT Manufacturing Company 2006, 2007 All rights reserved 10 LINE CYLINDRICAL SARGENT Manufacturing Company 2006, 2007 All rights reserved 1 6/01/07 SARGENT Manufacturing Company????,???? or????-???? All rights reserved LEVER LOCKS Specifications Table of Contents

More information

SECTION AUTOMATIC TRANSFER SWITCHES

SECTION AUTOMATIC TRANSFER SWITCHES PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 36 23 This section specifies the furnishing, complete installation, and connection of automatic transfer switches. 1.2 RELATED WORK A. Section 14 21 00, ELECTRIC

More information

SECTION COMMERCIAL DOOR OPERATORS OVERHEAD RSX FIRE DOOR OPERATOR

SECTION COMMERCIAL DOOR OPERATORS OVERHEAD RSX FIRE DOOR OPERATOR SECTION 08734 COMMERCIAL DOOR OPERATORS OVERHEAD RSX FIRE DOOR OPERATOR Display hidden notes to specifier by using Tools / Options / View / Hidden Text. PART 1 GENERAL 1.1 SECTION INCLUDES A. Overhead

More information

LOCK INTO THE ACSI ADVANTAGE LOCK INTO THE ACSI ADVANTAGE

LOCK INTO THE ACSI ADVANTAGE LOCK INTO THE ACSI ADVANTAGE LOCK INTO THE ACSI ADVANTAGE LOCK INTO THE ACSI ADVANTAGE MODIFICATIONS TO: ADAMS RITE ARROW CORBIN RUSSWIN DORMA DOROMATIC MONARCH PRECISION SARGENT VON DUPRIN YALE and more SERIES 1500 EXIT DEVICES CATALOG

More information

Recommended location under the current MasterFormat 2004 is Section Elevator Door Smoke Containment System.

Recommended location under the current MasterFormat 2004 is Section Elevator Door Smoke Containment System. SMOKE GUARD SYSTEM MODEL 600 REV. 3 SPECIFICATION Smoke Guard, Inc 287 Maple Grove Boise, ID 83704 Toll Free: 800.574.0330 Fax: 208.639.7851 e-mail: info@smokeguard.com website: http://www.smokeguard.com/

More information

SECTION INTRUSION DETECTION SYSTEM

SECTION INTRUSION DETECTION SYSTEM SECTION 13845 INTRUSION DETECTION SYSTEM PART 1 GENERAL 1.01 SUMMARY A. Section Includes: A complete, operable, tested intrusion detection system, bearing Underwriters Laboratories (UL) mercantile listing

More information

SECTION EXTERIOR LIGHTING

SECTION EXTERIOR LIGHTING SECTION 26 56 00 PART 1 - GENERAL 1.1 DESCRIPTION This section specifies the furnishing, installation, and connection of exterior luminaries, controls, poles and supports. 1.2 RELATED WORK A. Section 26

More information