TEST REPORT. Contact No: SAMPLE NOT DRAWN BY OUR LABORATORY. THE RESULTS RELATE ONLY TO THE ITEMS TESTED

Size: px
Start display at page:

Download "TEST REPORT. Contact No: SAMPLE NOT DRAWN BY OUR LABORATORY. THE RESULTS RELATE ONLY TO THE ITEMS TESTED"

Transcription

1 Issue No:01, Issue Date: Page 1 of 8 CIN:U74220DL1998PLC Test Report Issued To: ELEVEN CARPETS(U.P) Test Report No: / Date of Issue: 04-Oct-2017 SHAHAWABAD, BHADOHI, UTTAR PRADESH, INDIA, , Sample Receipt Date: Date of Start of Testing: Date of Completion of Test: 11-Sep Oct Oct-2017 Customer Relationship Number Sample Description : HAND TUFTED SIZE-520X7320MM Customer Reference No : WO/PO No: Kind Attention : MR SACHIN GUPTA sachin.elevencarpets@gmail.com Contact No: NA Sample Condition : Sample Quantity (Approx) : Sample Size (Approx) : SAMPLE NOT DRAWN BY OUR LABORATORY. THE RESULTS RELATE ONLY TO THE ITEMS TESTED Report Issued by Authencity of report can be verified by mail at verification@spectrolab.in This is a Digitally Signed Report and hence doesn't require Physical Signature. Spectro Analytical Labs Limited S-1, GNEPIP, Surajpur Industrial Area,Phase-V, Kasna, Greater Noida (India) Phone : , URL : care@spectro.in BIS & DDA Approved, ISO 9001:2008, ISO 14001:2004 & OHSAS 18001:2007 Certified Laboratory Please refer to our Website for Terms & Condition

2 Page 2 of 8 Test Requested Steiner Tunnel Test for determining the spread of flame and Smoke developed during burning behavior of building materials. Test Period Test Period Scope of Job Performing spread of flame and Smoke developed test on Carpet as per ASTM E84 16: Standard Test Method for Surface Burning Characteristics of Building Materials. Sample Receiving Date : 11 th September 2017 Test Starting Date : 3 rd October 2017 Test Completion Date : 3 rd October 2017 Product Name Carpet Hand tufted, NZ Wool & Bamboo Silk Manufacturer Eleven Carpets Test Report Issued To Eleven Carpets, Shahawabad, Post Naya Bazaar, Bhadohi , U.P., India Details of Specimen Tested Length : 7300 mm Breadth : 540 mm Thickness : 20 mm Details Verified By: HOD Fire testing department Spectro Analytical Labs Ltd.

3 Page 3 of 8 Ambient Temperature At the time of Commencement of test the Average ambient Temperature was found to be C. Sample Preparation The Carpet was fixed to the MS Channel on both sides by rivets. The Carpet was 20 mm in total thickness by 540 mm in width by 7320 mm in length. The carpet was spread over the tunnel to form the requisite specimen length. Prior to testing, the sample was conditioned to constant weight at a temperature of 73 ± 5 F (23 ± 3 C) and a relative humidity of 50 ± 5%. During testing the sample was self-supporting and the surface containing white lines was exposed to the test flame. Results and Discussion Flame Spread Result Calculated Flame Spread (CFS) Flame Spread Index 30 Smoke Developed Result Calculated Smoke Developed Smoke Developed Index 1000 Note: For Further details and observations refer to Annexure A and B

4 Annexure A CORRECTION FACTOR Page 4 of 8 CORRECTION FACTOR FOR CALCULATING FLAME SPREAD INDEX If this total area (A T ) is less than or equal to 97.5 ft min then The flame spread index shall be FSI = 0.515* A T. If the total area (A T ) is greater than 97.5 ft min then The flame spread index shall be FSI = 4900/ (195 - A T ). Here A T represents Total Area i.e. A T = A 1 + A 2 A 1 = Area Under the curve where first peak is observed. A 2 = Area just above the curve in the line of First peak point. CORRECTION FACTOR FOR CALCULATING SMOKE DEVELOPED INDEX Smoke Developed (SD) is determined by dividing the total area under the obscuration curve by that of cement board, and multiplying by 100. SD is then rounded to the nearest multiple of 5 if less than 200. SD values over 200 are rounded to the nearest multiple of 50. Smoke Developed Index = Area under the Obscuration Curve x100 Area under the Red Oak Curve

5 Page 5 of 8 OBTAINED DATA Flame Spread Data Time(minutes) Distance(Feet) 1 Ignition Flame Spread data Calculated Flame Spread (CFS) 32.7 Flame Spread Index 30 Time to Ignition (sec) Maximum Flame Spread (Ft) Area under the Flame Spread Curve (Ft. Min) 60 sec 10.0 ft ft. min Smoke Data Calculated Smoke Developed Smoke Developed Index 1000 Area under the Smoke Curve Area under Red Oak Curve 73.87

6 Page 6 of 8 ANNEXURE B GRAPHS Temperature Time Graph

7 Photographs Page 7 of 8 Photograph Exposed face before starting the test Photograph Un-Exposed face before starting the test

8 Page 8 of 8 Test Location The test was conducted at our Laboratory M/s. Spectro Analytical Labs Limited S-1 GNEPIP, Surajpur Industrial Area Kasna, Greater Noida, Phase V Gautam Budha Nagar (U.P.) Pin Code: Ph: / End of Test Report

Test Report No. AJFS FF Date: OCT.17, 2018 Page 1 of 6

Test Report No. AJFS FF Date: OCT.17, 2018 Page 1 of 6 Art3d LLC Test Report No. AJFS1809009217FF Date: OCT.17, 2018 Page 1 of 6 1600 N State Route 291 Unit 250, Sugar Creek, Missouri 64058 USA 中国认可国际互认检测 TESTING CNAS L4743 The following sample(s) was / were

More information

RENDERED TO. Laminam S.P.A. Via Ghiarola Nuova Fiorano Modenese Italy

RENDERED TO. Laminam S.P.A. Via Ghiarola Nuova Fiorano Modenese Italy REPORT NUMBER: 100900037COQ-002 ORIGINAL ISSUE DATE: October 10, 2012 TEST REPORT EVALUATION CENTER Intertek Testing Services NA Ltd. 1500 Brigantine Drive Coquitlam, BC V3K 7C1 RENDERED TO Laminam S.P.A.

More information

TEST REPORT EVALUATION CENTER Intertek Testing Services NA Ltd Brigantine Drive Coquitlam, B.C. V3K 7C1

TEST REPORT EVALUATION CENTER Intertek Testing Services NA Ltd Brigantine Drive Coquitlam, B.C. V3K 7C1 REPORT NUMBER: 101145164COQ-005 ORIGINAL ISSUE DATE: April 25, 2013 TEST REPORT EVALUATION CENTER Intertek Testing Services NA Ltd. 1500 Brigantine Drive Coquitlam, B.C. V3K 7C1 RENDERED TO udecor Inc.

More information

FUNDERMAX GMBH FIRE TEST REPORT

FUNDERMAX GMBH FIRE TEST REPORT FUNDERMAX GMBH FIRE TEST REPORT SCOPE OF WORK ASTM E84 TESTING ON 19 MM MAX COMPACT REPORT NUMBER I0002.02-121-24 TEST DATE 01/29/18 ISSUE DATE 02/16/18 RECORD RETENTION END DATE 01/29/22 PAGES 10 DOCUMENT

More information

SIGMADEK, LTD. FIRE TEST REPORT

SIGMADEK, LTD. FIRE TEST REPORT SIGMADEK, LTD. FIRE TEST REPORT SCOPE OF WORK ASTM E84 TESTING ON ALUMINUM EXTRUSION DECK BOARD C/W PORCELAIN TILE INSERT REPORT NUMBER H5331.01-121-24 TEST DATE 09/13/17 ISSUE DATE 10/03/17 RECORD RETENTION

More information

FABRITRAK SYSTEMS, INC. FIRE TEST REPORT

FABRITRAK SYSTEMS, INC. FIRE TEST REPORT FABRITRAK SYSTEMS, INC. FIRE TEST REPORT SCOPE OF WORK ASTM E84 TESTING ON POLYESTER INFILL REPORT NUMBER H5200.01-121-24 TEST DATE 08/31/17 ISSUE DATE 09/20/17 RECORD RETENTION END DATE 08/31/21 PAGES

More information

RENDERED TO. Radial Engineering Limited 1588 Kebet Way Port Coquitlam, B.C. V3C 5M5

RENDERED TO. Radial Engineering Limited 1588 Kebet Way Port Coquitlam, B.C. V3C 5M5 REPORT NUMBER: 3189147COQ-002 ORIGINAL ISSUE DATE: September 30, 2009 TEST REPORT EVALUATION CENTER Intertek Testing Services NA Ltd. 1500 Brigantine Drive Coquitlam, B.C. V3K 7C1 RENDERED TO Radial Engineering

More information

Test Report No. AJD Date: JUN.09, 2013 Page 1 of 6

Test Report No. AJD Date: JUN.09, 2013 Page 1 of 6 Test Report No. AJD201302471 Date: JUN.09, 2013 Page 1 of 6 WALER PRECISION MFG. SDN. BHD. NO.2, JALAN CANGGIH 1, TAMAN PERINDUSTRIAN CEMERALNG, 81800 ULU TIRAM, JOHOR, MALAYSIA. The following sample(s)

More information

We Identify and S.T.O.P. Your Noise Problems

We Identify and S.T.O.P. Your Noise Problems ASTM E-84 TESTING FOR MANUFACTURER, RENDERED TO: Acoustical Surfaces Inc. 123 Columbia Court North, Suite 201 Chaska, MN 55318 Noise S.T.O.P. Fabrisorb Acoustical Wall Panels TESTED: OCTOBER 3, 2002 October

More information

CAN/ULC-S102 Surface Burning Characteristics of "ezobord 9 mm (Green)"

CAN/ULC-S102 Surface Burning Characteristics of ezobord 9 mm (Green) UNCONTROLLED ELECTRONIC COPY CAN/ULC-S12 Surface Burning Characteristics of "ezobord 9 mm (Green)" A Report To: ivekter Inc. 1625 Drew Rd. Mississauga, Ontario L5S 1J5 Phone: 416-665-3571 Attention: E-mail:

More information

RENDERED TO Vipco Industries Inc th Avenue SE Calgary, AB T2C 0B3

RENDERED TO Vipco Industries Inc th Avenue SE Calgary, AB T2C 0B3 REPORT NUMBER: 101207560COQ-001b ORIGINAL ISSUE DATE: June 12, 2013 TEST REPORT EVALUATION CENTER Intertek Testing Services NA Ltd. 1500 Brigantine Drive Coquitlam, B.C. V3K 7C1 RENDERED TO Vipco Industries

More information

TEST REPORT. Report No.: D Rendered to: 3M COMPANY St. Paul, Minnesota

TEST REPORT. Report No.: D Rendered to: 3M COMPANY St. Paul, Minnesota Architectural Testing TEST REPORT Report No.: D7913.05-121-24 Rendered to: 3M COMPANY St. Paul, Minnesota PRODUCT TYPE: Window Film SERIES/MODEL: 3M Scotchshield Ultra 800 TEST METHOD: ASTM E 84-11a, Standard

More information

Contents: 4. Report of Surface Burning Characteristics Tests on LP FlameBlock/BlazeGuard (30-minute test) Updated April, 2010

Contents: 4. Report of Surface Burning Characteristics Tests on LP FlameBlock/BlazeGuard (30-minute test) Updated April, 2010 Contents: 1. ASTM E 84 (UL 723) Flame Spread Test Report 1 2. ASTM E 84 (UL 723) Flame Spread Test Report 2 3. ASTM E 84 (UL 723) Flame Spread Test Report 3 Updated April, 2010 4. Report of Surface Burning

More information

Report Of Surface Burning Characteristics Tests On Felt Material As Submitted By Rieke Office Interiors

Report Of Surface Burning Characteristics Tests On Felt Material As Submitted By Rieke Office Interiors February 2, 16 Rieke Office Interiors Mr. Todd Rieke Fox Ln. Elgin, IL 6123 Our Reference: SV3565 / 4787326412 Subject: Report Of Surface Burning Characteristics Tests On Felt Material As Submitted By

More information

CAN/ULC-S102 Surface Burning Characteristics of "Digitally Printed Aluminum Siding" Coated Aluminum

CAN/ULC-S102 Surface Burning Characteristics of Digitally Printed Aluminum Siding Coated Aluminum UNCONTROLLED ELECTRONIC COPY CAN/ULC-S12 Surface Burning Characteristics of "Digitally Printed Aluminum Siding" Coated Aluminum A Report To: DiZal inc. 12 rue Bouvier, Suite 4 Québec, QC G2K K9 Phone:

More information

Report of Surface Burning Characteristics Tests on Samples As Submitted By Eco-Sol Ltd

Report of Surface Burning Characteristics Tests on Samples As Submitted By Eco-Sol Ltd October 05, 2011 Eco-Sol Ltd Mr. Paul Allcock Cardiff House Cardiff Rd Barry, Vale of Glamorgan, CF63 2AW Great Britain Our Reference: Subject: R27181/11CA40094 Report of Surface Burning Characteristics

More information

TEST REPORT. Report No.: E Test Date: May 6, Rendered to: FUNDERMAX GMBH A-9300 St. Veit an der Glan, Austria

TEST REPORT. Report No.: E Test Date: May 6, Rendered to: FUNDERMAX GMBH A-9300 St. Veit an der Glan, Austria TEST REPORT Report No.: E6736.01-121-24 Test Date: May 6, 2015 Rendered to: FUNDERMAX GMBH A-9300 St. Veit an der Glan, Austria PRODUCT TYPE: Max Exterior F-Quality SERIES/MODEL: Décor. 0085 TEST METHOD:

More information

ASTM D Horizontal Burning Rate Determination of "Marlon FS 1.5mm Clear" Polycarbonate Sheet

ASTM D Horizontal Burning Rate Determination of Marlon FS 1.5mm Clear Polycarbonate Sheet UNCONTROLLED ELECTRONIC COPY ASTM D 635-14 Horizontal Burning Rate Determination of "Marlon FS 1.5mm Clear" Polycarbonate Sheet A Report To: Brett Martin Ltd. 24 Roughfort Road Mallusk, Co. Antrim United

More information

Report Of Surface Burning Characteristics Tests On Samples As Submitted By Railtech Ltd.

Report Of Surface Burning Characteristics Tests On Samples As Submitted By Railtech Ltd. May 22, 2013 Mr. Herbert Wheeler Railtech Ltd. 325 Ave. Lee Baie-D urf, QX 3S3 Canada Our Reference: Subject: R26549/13CA21763 Report Of Surface Burning Characteristics Tests On Samples As Submitted By

More information

Report of Surface Burning Characteristics Tests on Skyfold Panel Samples As Submitted By Railtech Ltd

Report of Surface Burning Characteristics Tests on Skyfold Panel Samples As Submitted By Railtech Ltd November 29, 2010 Revised: January 10, 2013 Revised: January 18, 2013 Mr. Herbert Wheeler Railtech Ltd. 325 Ave Lee, Baie-D Urf QC H9X 3S3 Canada Our Reference: Subject: R26549/09CA56627 Report of Surface

More information

Report Of Surface Burning Characteristics Tests On PVC Sheeting As Submitted By Jain (Americas) Inc.

Report Of Surface Burning Characteristics Tests On PVC Sheeting As Submitted By Jain (Americas) Inc. December 6, 7 Jain (Americas) Inc. Ms. Sara B. Schopfer 1819 Walcutt Road Suite 1 Columbus, OH 43228 Our Reference: Subject: SV17122 / 7CA56359 Report Of Surface Burning Characteristics Tests On PVC Sheeting

More information

CAN/ULC-S102 Surface Burning Characteristics of "8 mm Fire Rated High Pressure Laminate Phenolic Panel"

CAN/ULC-S102 Surface Burning Characteristics of 8 mm Fire Rated High Pressure Laminate Phenolic Panel ELECTRONIC DRAFT COPY CAN/ULC-S12 Surface Burning Characteristics of "8 mm Fire Rated High Pressure Laminate Phenolic Panel" A Report To: ABET Corporation 5 Paxman Road, Unit 1 Toronto, Ontario M9C 1B7

More information

Report Of Surface Burning Characteristics Tests On Coated Louvered Door Panels As Submitted By Contego International Inc.

Report Of Surface Burning Characteristics Tests On Coated Louvered Door Panels As Submitted By Contego International Inc. August 11, 2017 Contego International Inc. Mr. Danny French PO Box 49 Rochester, IN 46975-0049 Our Reference: R25382 / 4788022828 Subject: Report Of Surface Burning Characteristics Tests On Coated Louvered

More information

Report Of Surface Burning Characteristics Tests On Samples As Submitted By Textures 3D

Report Of Surface Burning Characteristics Tests On Samples As Submitted By Textures 3D November 10, 2014 Mr. Carlos Khantzis Textures 3D 31280 Oak Crest Dr. #4 Westlake Village, CA 91361 Our Reference: Subject: SV19490/4786557998 Report Of Surface Burning Characteristics Tests On Samples

More information

Report of Surface Burning Characteristics Test on Acoustical Panel

Report of Surface Burning Characteristics Test on Acoustical Panel January 02, 2013 Ideacustik Christian Morales Torres Gerente General Av. Quito 3620 y Bolivia Guayaquil, Ecuador Our Reference: Subject: R27636 / 12CA68539 Report of Surface Burning Characteristics Test

More information

Report Of Surface Burning Characteristics Tests On Fire Retardant Coating As Submitted By Contego International

Report Of Surface Burning Characteristics Tests On Fire Retardant Coating As Submitted By Contego International January 3, 7 Mr. Danny French Contego International 334 Greyhound Pass West Carmel, IN 4632 Our Reference: Subject: R25382 / 6CA51291 Report Of Surface Burning Characteristics Tests On Fire Retardant Coating

More information

GUARDIAN FIRE TESTING LABORATORIES, INC.

GUARDIAN FIRE TESTING LABORATORIES, INC. GUARDIAN FIRE TESTING LABORATORIES INC. Testing & Listing Field Labeling Page 1 of 5 Engineering & Product Certification Services Factory Inspections Guardian Fire Testing Laboratories, Inc. Phone: 716

More information

Report of Surface Burning Characteristics Tests on Samples As Submitted By Jotun UAE Ltd (LLC)

Report of Surface Burning Characteristics Tests on Samples As Submitted By Jotun UAE Ltd (LLC) February, 11 Revised February 28, 11 Jotun UAE Ltd (LLC) Mr. Richard Mann Al Quozind District Dubai, 3671 UAE Our Reference: Subject: SV18666/11CA24 Report of Surface Burning Characteristics Tests on Samples

More information

Report Of Surface Burning Characteristics Tests On Samples As Submitted By Tile-diy LLC

Report Of Surface Burning Characteristics Tests On Samples As Submitted By Tile-diy LLC Mr. Seth Wentz Tile-diy LLC 1965 International Way Hebron, KY 41048 United States Our Reference: Subject: SV17262/08CA11093 Report Of Surface Burning Characteristics Tests On Samples As Submitted By Tile-diy

More information

Acoustical Surfaces, Inc.

Acoustical Surfaces, Inc. S.T.O.P. February 21, 2013 Our Reference: Subject: SV19452/13CA09185 Report Of Surface Burning Characteristics Tests On Samples This is a Report summarizing the results of a test conducted under the Commercial

More information

Report Of Surface Burning Characteristics Tests On Samples As Submitted By Ebrille SRL

Report Of Surface Burning Characteristics Tests On Samples As Submitted By Ebrille SRL May 18, 2015 Mr. Simone Furiato Ebrille SRL S S Canelli 53/A Nizza Monferrato, AT 14049 Our Reference: Subject: SV29774/4786853196 Report Of Surface Burning Characteristics Tests On Samples As Submitted

More information

EnviroScape Mural. pre-pasted printable wallcovering material. Choose your GREEN resource from a leading solutions provider.

EnviroScape Mural. pre-pasted printable wallcovering material. Choose your GREEN resource from a leading solutions provider. by NEENAH EnviroScape Mural pre-pasted printable wallcovering material EnviroScape Mural is a PVC free wall, window or hard surface scaping product that is pre-pasted with a water activated adhesive backing

More information

ASTM E84-99 ADHERED SURFACE BURNING CHARACTERISTICS

ASTM E84-99 ADHERED SURFACE BURNING CHARACTERISTICS ASTM E84-99 ADHERED SURFACE BURNING CHARACTERISTICS SPANK 9901101 REPORT NO. 75157 Septemer 11, 00 Prepared For: Pollack 150 Varick Street New York, NY 10013 F-316-A 555 76TH STREET S.W., GRAND RAPIDS.

More information

REPORT NUMBER: SAT-001B ORIGINAL ISSUE DATE: February 29, 2016 REVISED DATE:

REPORT NUMBER: SAT-001B ORIGINAL ISSUE DATE: February 29, 2016 REVISED DATE: Page 1 of 10 TEST REPORT REPORT NUMBER: 102317918SAT-001B ORIGINAL ISSUE DATE: February 29, 2016 REVISED DATE: EVALUATION CENTER Intertek Testing Services NA Inc. 16015 Shady Falls Road Elmendorf, TX 78112

More information

BCTC CARPET TECHNICAL CENTRE

BCTC CARPET TECHNICAL CENTRE Wira House West Park Ring Road Leeds, LS16 6QL Tel: +44 (0)113 259 1999 Fax: +44 (0)113 278 0306 Web: http://www.bttg.co.uk/bctc Email: CSLeeds@bttg.co.uk 7 September 2010 Page 1 of 7 Client: Rectory Farm

More information

CAN/ULC-S102.2 Surface Burning Characteristics of "16 mm Multiwall Polycarbonate"

CAN/ULC-S102.2 Surface Burning Characteristics of 16 mm Multiwall Polycarbonate ELECTRONIC DRAFT COPY CAN/ULC-S12.2 Surface Burning Characteristics of "16 mm Multiwall Polycarbonate" A Report To: Polygal Plastics Industries, Ltd. Ramat Hashofet 19238 Israel Phone: 972-4-9596271 Email:

More information

CLASSIFICATION REPORT

CLASSIFICATION REPORT CLASSIFICATION REPORT NUMBER 251.C.1804.020.EN.01 Work sheet: 21801003 DATE OF ISSUE April 10 th, 2018 NOTIFIED BODY PAGE TEST SPECIMEN CONCERNING TO APPLICANT DATE/S OF TEST AUTORIZED SIGNATORIES Notified

More information

The Decision You Make May Save A Life! 123 Columbia Court North Suite 201 Chaska, MN 55318

The Decision You Make May Save A Life! 123 Columbia Court North Suite 201 Chaska, MN 55318 Retardants Inc. The Decision You Make May Save A Life! 123 Columbia Court North Suite 21 Chaska, MN 55318 952-448-7377 FAX:952-448-2613 Fire Retardant HOT LINE 1-8-913-9385 e-mail: info@fireretardantsinc.com

More information

Technical Training International Textiles Training September 2018 Ellen Roaldi Instructor

Technical Training International Textiles Training September 2018 Ellen Roaldi Instructor Technical Training International Textiles Training September 2018 Ellen Roaldi Instructor www.astm.org ASTM D1230 Flammability of Apparel Textiles Scope: This test method covers the evaluation of the flammability

More information

ASTM E 84 Surface Burning Characteristics of "12 mm Stratificato Panel"

ASTM E 84 Surface Burning Characteristics of 12 mm Stratificato Panel UNCONTROLLED ELECTRONIC COPY ASTM E 84 Surface Burning Characteristics of "12 mm Stratificato Panel" A Report To: ABET Inc. 60 West Sheffield Avenue Englewood, NJ 07631 USA Phone: 201-541-700 Web: www.abetlaminati.com

More information

Analysis Report

Analysis Report Prestige Carpets bvba Dhr. Dirk Santens Klein Frankrijk 38 9600 RONSE Your notice of Your reference Date 19-06-2013 24-07-2013 Required tests : Identification number T1309624 Information given by the client

More information

UNNATI FORTUNE WORLD PLOT 5, SECTOR 144, SEZ NOIDA UNNATI FORTUNE WORLD, NOIDA A R C O P

UNNATI FORTUNE WORLD PLOT 5, SECTOR 144, SEZ NOIDA UNNATI FORTUNE WORLD, NOIDA A R C O P UNNATI FORTUNE WORLD PLOT 5, SECTOR 144, SEZ NOIDA SITE LOCATION UNNATI FORTUNE WORLD SITE PARAMETERS Site Area: 1,00,000 sqm/ 1076400 sqft DESIGN PARAMETERS An ICONIC DEVELOPMENT that will embrace locally

More information

TEST REPORT. NFPA 253 / ASTM E648-14c Standard Test Method for Critical Radiant Flux of Floor-Covering Systems Using a Radiant Heat Energy Source

TEST REPORT. NFPA 253 / ASTM E648-14c Standard Test Method for Critical Radiant Flux of Floor-Covering Systems Using a Radiant Heat Energy Source NFPA 253 / ASTM E648-14c Standard Test Method for Critical Radiant Flux of Floor-Covering Systems Using a Radiant Heat Energy Source TEST REPORT Kolay 5mm 20mil Wear Layer LVT with Fiberglass Core Project

More information

PERFORMANCE TEST REPORT. Rendered to: VELUX America, Inc. PRODUCT: SUN TUNNEL Acrylic Dome

PERFORMANCE TEST REPORT. Rendered to: VELUX America, Inc. PRODUCT: SUN TUNNEL Acrylic Dome PERFORMANCE TEST REPORT Rendered to: VELUX America, Inc. PRODUCT: SUN TUNNEL Acrylic Dome Report No: D3964.01-106-31 Report Date: 06/19/14 Test Record Retention Date: 06/03/18 130 Derry Court York, PA

More information

ASSESSING THE FIRE PERFORMANCE OF ELECTRIC CABLES (FIPEC)

ASSESSING THE FIRE PERFORMANCE OF ELECTRIC CABLES (FIPEC) ASSESSING THE FIRE PERFORMANCE OF ELECTRIC CABLES (FIPEC) P. Van Hees and J. Axelsson, SP Sweden, S. J. Grayson and A. M. Green, Interscience Communications UK, H Breulet, ISSeP Belgium and U Vercellotti,

More information

Research-Scale Fire Performance Evaluation of a Wood Floor Joist/Tin Ceiling Panel Assembly

Research-Scale Fire Performance Evaluation of a Wood Floor Joist/Tin Ceiling Panel Assembly Research-Scale Fire Performance Evaluation of a Wood Floor Joist/Tin Ceiling Panel Assembly ASTM E119-98: Standard Test Methods for Fire Tests of Building Construction and Materials* *Research-scale horizontal

More information

Classification of Fire Performance of Wall and Ceiling Lining Materials

Classification of Fire Performance of Wall and Ceiling Lining Materials Classification of Fire Performance of Wall and Ceiling Lining Materials Using the Method of Kokkala, Thomas and Karlsson Reference: Kokkala, M.A. Thomas, P.H. and Karlsson, B. Rate of Heat Release and

More information

BURNING BRAND PERFORMANCE TEST REPORT. Rendered to: VELUX AMERICA, INC. SERIES/MODEL: TGF/TGR (Acrylic Dome) VELUX SUN TUNNEL

BURNING BRAND PERFORMANCE TEST REPORT. Rendered to: VELUX AMERICA, INC. SERIES/MODEL: TGF/TGR (Acrylic Dome) VELUX SUN TUNNEL BURNING BRAND PERFORMANCE TEST REPORT Rendered to: VELUX AMERICA, INC. SERIES/MODEL: TGF/TGR 022 0000 (Acrylic Dome) VELUX SUN TUNNEL ACCESSORY PRODUCTS: Tubular Skylight with ZTA 022 000090 9" Turrets

More information

FIRE RETARDANT ARCHITECTURAL WOOD COATING FIRE SHIELD FS020 FIRE-SHIELD SEALER. FS021 FIRE-SHIELD TOP COAT Available in different gloss

FIRE RETARDANT ARCHITECTURAL WOOD COATING FIRE SHIELD FS020 FIRE-SHIELD SEALER. FS021 FIRE-SHIELD TOP COAT Available in different gloss FIRE RETARDANT ARCHITECTURAL WOOD COATING ASTM E84 CLASS A FIRE SHIELD FS020 FIRE-SHIELD SEALER FS021 FIRE-SHIELD TOP COAT Available in different gloss www.duro-lak.com Easy to apply Water base sealer

More information

C-01 FIRE DECKS AND BULKHEADS

C-01 FIRE DECKS AND BULKHEADS Guideline No.: C-01(201510) C-01 FIRE DECKS AND BULKHEADS Issued date: October 20,2015 China Classification Society Foreword: This Guide is a part of CCS Rules, which contains technical requirements, inspection

More information

Analysis Report

Analysis Report Forbo Flooring Coral nv Dhr. Jan van Galen Postbus 17 1560 AA KROMMENIE Nederland Your notice of Your reference Date 08-02-2016 23-02-2016 Analysis Report 16.00634.08 Required tests : Identification number

More information

Tech Notes. TESTING PROTOCOL Fire Retardant Gel Coats. INTERPLASTIC CORPORATION Thermoset Resins Divison ISSUE 5

Tech Notes. TESTING PROTOCOL Fire Retardant Gel Coats. INTERPLASTIC CORPORATION Thermoset Resins Divison ISSUE 5 INTERPLASTIC CORPORATION Thermoset Resins Divison ISSUE 5 5 Tech Notes TESTING PROTOCOL Fire Retardant Gel Coats Issue Date: 4/22/2010 Document ID: TN-TS-05A 2010 Interplastic Corporation Testing Protocol

More information

TFI Report Reaction to fire test

TFI Report Reaction to fire test TFI Report 450740-07 Reaction to fire test For the classification according to EN 13501-1:2010 Customer GÜLSEVEN HALI GÜLSEVEN TEKSTIL KIMYA GIDA SAN. TIC. LTD. STI Ahi Evran Sanayi Sitesi Istiklal Caddesi

More information

Contents Page No. Page 1 of Introduction Specimen verification Description of supporting constructions...

Contents Page No. Page 1 of Introduction Specimen verification Description of supporting constructions... Contents Page No Page 1 of 14... 1 1 Introduction... 3 2 Specimen verification... 3 3 Description of supporting constructions... 3 4 Description of specimen... 3 4.1 Air transfer grille blocks... 3 5 Test

More information

Forbo Flooring Attn. Mr. A. Tijhof Postbus AA Krommenie. Report. Sponsor : Contractor, manufacturer : Forbo Flooring. Lot. No. : 66869/3877.

Forbo Flooring Attn. Mr. A. Tijhof Postbus AA Krommenie. Report. Sponsor : Contractor, manufacturer : Forbo Flooring. Lot. No. : 66869/3877. Return address: P.O. box 337, 7500 AH Enschede, TNO Centre for Textile Research Ariënsplein 3 7511 JX ENSCHEDE Forbo Flooring Attn. Mr. A. Tijhof Postbus 13 1560 AA Krommenie Report Sponsor : Contractor,

More information

VASTHI ENGINEERS. Vasthi Explosive Meter Sheet No. 1 of 5. Vasthi Monitors for Combustible Gas.

VASTHI ENGINEERS. Vasthi Explosive Meter Sheet No. 1 of 5. Vasthi Monitors for Combustible Gas. Vasthi Explosive Meter Sheet No. 1 of 5 000000000000000000000 Vasthi Monitors for Combustible Gas. Vasthi Explosive Meter Sheet No. 2 of 5 Description : Vasthi (Model VS-70 E) HAND HELD PORTABLE COMBUSTIBLE

More information

SOUTHWEST RESEARCH INSTITUTE

SOUTHWEST RESEARCH INSTITUTE SOUTHWEST RESEARCH INSTITUTE 6220 CULEBRA ROAD 78238-5166 P.O. DRAWER 28510 78228-0510 SAN ANTONIO, TEXAS, USA (210) 684-5111 WWW.SWRI.ORG CHEMISTRY AND CHEMICAL ENGINEERING DIVISION FIRE TECHNOLOGY DEPARTMENT

More information

Contact person Date Reference Page Richard Johansson P (2) Fire Research

Contact person Date Reference Page Richard Johansson P (2) Fire Research issued by an Accredited Testing Laboratory Contact person Richard Johansson 215-8-13 5P4413 1 (2) Fire Research +46 1 516 56 75 richard.johansson@sp.se 12 ISO/IEC 1725 Sklejka-Pisz Paged S.A Ul. kwiatowa

More information

CANADIAN FIRE ALARM ASSOCIATION An Update on Standards, Technologies and Solutions. Smoke Characterization Study

CANADIAN FIRE ALARM ASSOCIATION An Update on Standards, Technologies and Solutions. Smoke Characterization Study CANADIAN FIRE ALARM ASSOCIATION An Update on Standards, Technologies and Solutions Smoke Characterization Study October 29, 2008 Paul E. Patty, P.E. Senior Research Engineer Northbrook, IL 847-664-2752

More information

Analysis of Triangle Heating Technique using High Frequency Induction Heating in Forming Process of Steel Plate

Analysis of Triangle Heating Technique using High Frequency Induction Heating in Forming Process of Steel Plate Analysis of Triangle Heating Technique using High Frequency Induction Heating in Forming Process of Steel Plate KEYWORDS: Steel-plate forming, Induction heating, Triangle heating, Transverse shrinkage,

More information

Report on the Fire Testing of a Roofing System with a Synthetic Underlayment in Accordance with ASTM E a. Trinity ERD Columbia, SC

Report on the Fire Testing of a Roofing System with a Synthetic Underlayment in Accordance with ASTM E a. Trinity ERD Columbia, SC Report on the Fire Testing of a Roofing System with a Synthetic Underlayment in Accordance with ASTM E 108-07a Rendered to: Trinity ERD Columbia, SC WFCi Project # 10135 & 11159 Testing Completed on: April

More information

WARRES No Page 1 of 27. Fire Resistance Test Generally In Accordance With BS 476: Part 22: 1987, Clause 5, on an Insulated Fabric Barrier

WARRES No Page 1 of 27. Fire Resistance Test Generally In Accordance With BS 476: Part 22: 1987, Clause 5, on an Insulated Fabric Barrier Page 1 of 27 Fire Resistance Test Generally In Accordance With BS 476: Part 22: 1987, Clause 5, on an Insulated Fabric Barrier Test Sponsor Saveguard (UK) Limited Warrington Fire Research Centre Ltd.,

More information

PRODUCT PERFORMANCE TEST REPORT. Report No.: D Test Date: May 29, Rendered to: Natural Light Energy Systems Phoenix, Arizona

PRODUCT PERFORMANCE TEST REPORT. Report No.: D Test Date: May 29, Rendered to: Natural Light Energy Systems Phoenix, Arizona Architectural Testing PRODUCT PERFORMANCE TEST REPORT Report No.: D7226.01-121-24 Test Date: May 29, 2014 Rendered to: Natural Light Energy Systems Phoenix, Arizona PRODUCT TYPE: Tubular Daylight Device

More information

Title: Fire resistance test utilising the general principles of BS 476: Part 20: 1987 on four specimens of Uninsulated Air Valves.

Title: Fire resistance test utilising the general principles of BS 476: Part 20: 1987 on four specimens of Uninsulated Air Valves. Title: Fire resistance test utilising the general principles of BS 476: Part 20: 1987 on four specimens of Uninsulated Air Valves Report No: 172158 Prepared for: Lindab Ventilation AB SE 26982 Båstad Järnvägsgatan

More information

Materials Testing by Gregory Havel

Materials Testing by Gregory Havel Materials Testing by Gregory Havel July 24, 2017 One of the most common tests cited in the technical bulletins on building materials is ASTM E84 Standard Method of Test of Surface Burning Characteristics

More information

Competent Crimping Machinery Pvt. Ltd.

Competent Crimping Machinery Pvt. Ltd. 08373904084 Competent Crimping Machinery Pvt. Ltd. www.crimptech.net Terminal Feed Applicators Industrial Equipments Digital Crimping Standard Presses We are a leading manufacturer of crimping machines

More information

#5 Proposed Revisions to the Acceptance Criteria for Metallic HVAC Duct Enclosure Assemblies, Subject AC179-1011-R1 (RB/MB) John D. Nicholas Representing Background Relevant to AC179 18 Years in the Building

More information

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009 P.O. Box 554 2665 ZN Bleiswijk Brandpuntlaan Zuid 16 2665 NZ Bleiswijk The Netherlands +31 88 3473 723 nederland@efectis.com CLASSIFICATION CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE

More information

Guidance Note. 3. Fire Propagation and flame Flame Spread in in Powder Coatings. Abrasion Resistance of Fluoropolymer and polyester Coatings

Guidance Note. 3. Fire Propagation and flame Flame Spread in in Powder Coatings. Abrasion Resistance of Fluoropolymer and polyester Coatings Guidance Note 3. Fire Propagation and flame Flame Spread in in Powder Coatings Abrasion Resistance of Fluoropolymer and polyester Coatings British Standards British Standard 476 refers to fire tests on

More information

Abrasion Resistance of Fluoropolymer and polyester Coatings

Abrasion Resistance of Fluoropolymer and polyester Coatings Abrasion Resistance of Fluoropolymer and polyester Coatings British Standards British Standard 476 refers to fire tests on building materials and structures. The parts of this standard that are of most

More information

NATIONAL TECHNICAL SYSTEMS

NATIONAL TECHNICAL SYSTEMS Test Report Number PR034844.CRW Testing of Test Samples PREPARED FOR: PREPARED BY: Crownduit 214 William Street Red Bank, NJ 07701 National Technical Systems 36 Gilbert Street South Tinton Falls, NJ 07701

More information

Report VNLF Test Report

Report VNLF Test Report Report VNLF 081158.1 Test Report Applicant KLEEN-TEX Industries in Europa GmbH Münchner Straße 21 6330-Kufstein Austria Reference Mrs. Antje Schlegel Application Determination ofthe burning behaviour according

More information

Second Revision No. 1-NFPA 90A-2016 [ Section No ] Submitter Information Verification. Committee Statement

Second Revision No. 1-NFPA 90A-2016 [ Section No ] Submitter Information Verification. Committee Statement Second Revision No. 1-NFPA 90A-2016 [ Section No. 2.3.2 ] 2.3.2 ASTM International Publications. ASTM International, 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959. ASTM C411, Standard

More information

Intertek. REPORT NUMBER: SAT-005 ORIGINAL ISSUE DATE: October 29,2008 REVISED DATE: November 19, 2008

Intertek. REPORT NUMBER: SAT-005 ORIGINAL ISSUE DATE: October 29,2008 REVISED DATE: November 19, 2008 Intertek I 0:: o D.. W 0:: I en w I REPORT NUMBER: 3161466SAT-005 ORIGINAL ISSUE DATE: October 29,2008 REVISED DATE: EVALUATION CENTER Intertek Testing Services NA Inc. 16015 Shady Falls Rd. Elmendorf,

More information

Title: Indicative fire test. WF Report No: /A. Prepared for: Hoody Speaker Hoods Ltd

Title: Indicative fire test. WF Report No: /A. Prepared for: Hoody Speaker Hoods Ltd Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 (0) 1925 655 116 F : +44 (0) 1925 655 419 E : warrington@exova.com W: www.exova.com Title: Indicative fire test WF Report

More information

FRANCE M & F RANKING ACCORDING TO NF F

FRANCE M & F RANKING ACCORDING TO NF F FRANCE M & F RANKING ACCORDING TO NF F 16-101 CREPIM / http://www.crepim.com 1 The actual classification used by French regulations for the classification of fire behaviour of materials/component is described

More information

CARTRIDGE EXTINGUISHER

CARTRIDGE EXTINGUISHER 48 CARTRIDGE EXTINGUISHER As mankind continues its march of progress, one threat remains a constant: Fire. Whether it is in state-of-the-art factories, in swank corporate offices or super-speciality hospitals,

More information

Test Report: ICL/CR15/11/087

Test Report: ICL/CR15/11/087 Interscience Fire Laboratory Building 63 Haslar Marine Technology Park Haslar Road, Gosport Hampshire PO12 2AG United Kingdom Tel. : +44 (0) 20 8692 5050 Fax.: +44 (0) 20 8692 5155 Email: firetesting@intersciencecomms.co.uk

More information

1.0 INTRODUCTION 2.0 CLASSIFICATION CRITERIA

1.0 INTRODUCTION 2.0 CLASSIFICATION CRITERIA 1.0 INTRODUCTION This report presents the results of an investigation of the external fire resistance characteristics of the VELUX FCM Deck Mounted Skylight roof covering system in general accordance with

More information

TFI Report Classification

TFI Report Classification TFI Report Classification of the Reaction to Fire according to EN 13501-1:2010 Customer Unilin bvba, Division Flooring Ooigemstraat 3 8710 Wielsbeke BELGIUM Product wall covering Wall covering This report

More information

FIRE-RESISTANCE TEST ON DOWNLIGHT COVERS INSTALLED IN PLASTERBOARD CEILINGS

FIRE-RESISTANCE TEST ON DOWNLIGHT COVERS INSTALLED IN PLASTERBOARD CEILINGS FIRE-RESISTANCE TEST ON DOWNLIGHT COVERS INSTALLED IN PLASTERBOARD CEILINGS Report number FSP 1290A CSIRO job number LP46ASP3085 Date of issue 30 NOVEMBER 2007 Client EFFICIENCY MATRIX PTY LTD and YOUNGEN

More information

THE IMPORTANCE OF FIRE DOORS

THE IMPORTANCE OF FIRE DOORS FIRE DOOR 01 THE IMPORTANCE OF FIRE DOORS In any building, you have the right to expect that you will be safe and protected whenever a fire breaks out. Sadly, this is not always the case. Sometimes, something

More information

Hugh Hoagland Consulting, Inc. Electric Arc Exposure Tests. For Innovative Textiles

Hugh Hoagland Consulting, Inc. Electric Arc Exposure Tests. For Innovative Textiles Hugh Hoagland Consulting, Inc. Electric Arc Exposure Tests For Innovative Textiles Fabric system Outer Layer: 5.5 oz/yd² IUS Twill, 88% Cotton 12% Nylon, Style 341, Khaki. 6.6 oz/yd² Inner Layer: 6.5 oz/yd²

More information

ASTM F25 SEMINAR Fire Testing for SOLAS and Navy Vessels New Test Procedures and Materials Approval Process

ASTM F25 SEMINAR Fire Testing for SOLAS and Navy Vessels New Test Procedures and Materials Approval Process ASTM F25 SEMINAR Fire Testing for SOLAS and Navy Vessels New Test Procedures and Materials Approval Process 2010 IMO FTP Code Revisions Parts 2, 5, 7, 8, 9 & 10 Presented by: Juan Manuel Flores, P.E. Date:

More information

Effect of Modification in Refrigerant Passage of an Automotive Air Conditioning Compressor

Effect of Modification in Refrigerant Passage of an Automotive Air Conditioning Compressor Purdue University Purdue e-pubs International Compressor Engineering Conference School of Mechanical Engineering 2006 Effect of Modification in Refrigerant Passage of an Automotive Air Conditioning Compressor

More information

Test on extruded rigid PVC profile for concrete formwork at 50 kw/m² irradiance in

Test on extruded rigid PVC profile for concrete formwork at 50 kw/m² irradiance in INFRASTRUCTURE TECHNOLOGIES Test on extruded rigid PVC profile for concrete formwork at 50 kw/m² irradiance in accordance with AS/NZS 3837:1998 Fire Testing Report Author: Heherson Alarde Report Number:

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SGS GOVMARK TESTING SERVICES, INC. 96 Allen Boulevard, Suite D Farmingdale, NY 11735 Doug Lipp Phone: 631 293 8944 THERMAL Valid To: May 31, 2018 Certificate

More information

STEEL DUCT - FIRE RATED CLADDING INSTALLATION MANUAL

STEEL DUCT - FIRE RATED CLADDING INSTALLATION MANUAL 14SH200001022 STEEL DUCT - FIRE RATED CLADDING INSTALLATION MANUAL DUCTLINER GS - VENTILATION, SMOKE OUTLET AND KITCHEN EXTRACT DUCT SYSTEMS Tested under BS 476: Part 24: 1987 Fire tests building materials

More information

Test Report No. AJHG FB Date: FEB.17, 2015 Page 1 of 13

Test Report No. AJHG FB Date: FEB.17, 2015 Page 1 of 13 Test Report No. AJHG1501000530FB Date: FEB.17, 2015 Page 1 of 13 ZHEJIANG TERASUN AIR DUCT CO., LTD MAREN VILLAGE, CHONGREN INDUSTRIAL ZONE, CHONGREN TOWN, SHENGZHOU CITY, ZHEJIANG PROVINCE, CHINA The

More information

In Search of Standard Reference Materials (SRMs) for ASTM E05 Fire Standards by. Norman Alvares & Harry Hasegawa

In Search of Standard Reference Materials (SRMs) for ASTM E05 Fire Standards by. Norman Alvares & Harry Hasegawa In Search of Standard Reference Materials (SRMs) for ASTM E05 Fire Standards by Norman Alvares & Harry Hasegawa First Paragraph of E-691 Tests performed on presumably identical materials in presumably

More information

ASTM E 662 Rate of Smoke Generation of "Moniflex as manufactured by Isoflex AB"

ASTM E 662 Rate of Smoke Generation of Moniflex as manufactured by Isoflex AB UNCONTROLLED ELECTRONIC COPY ASTM E 662 Rate of Smoke Generation of "Moniflex as manufactured by Isoflex AB" A Report To: Ciucevich 7200 Vermilion Ct. Wake Forest, NC 27587 USA Phone: (919) 570-291 E-mail:

More information

PERFORMANCE TEST REPORT. Rendered to: Metal Building Manufacturers Association Cleveland, Ohio

PERFORMANCE TEST REPORT. Rendered to: Metal Building Manufacturers Association Cleveland, Ohio PERFORMANCE TEST REPORT Report No.: F6398.01-121-24 Test Date: March 9 th & 10th, 2016 Rendered to: Metal Building Manufacturers Association Cleveland, Ohio ASSEMBLIES: Metal Roof Panels and Clay Roof

More information

IMO Resolution MSC 61 (67) 1996; Annex 1, Part 2. Smoke & Toxicity Test. WF Report Number: Date: 13 th August Test Sponsor:

IMO Resolution MSC 61 (67) 1996; Annex 1, Part 2. Smoke & Toxicity Test. WF Report Number: Date: 13 th August Test Sponsor: IMO Resolution MSC 61 (67) 1996; Annex 1, Part 2 Smoke & Toxicity Test WF Report Number: 166040 Date: 13 th August 2007 Test Sponsor: Fiba Tech Industries Ltd. 0249 Page 2 of 13 Bodycote warringtonfire

More information

SECTION ELEVATOR FIRE RATED SMOKE CONTAINMENT SYSTEM

SECTION ELEVATOR FIRE RATED SMOKE CONTAINMENT SYSTEM PART 1 - GENERAL 1.01 SUMMARY SECTION 08 34 84 ELEVATOR FIRE RATED SMOKE CONTAINMENT SYSTEM A. Section Includes: Fire protective elevator smoke containment curtain system designed to provide a tight-fitting,

More information

ASTM E662 TESTING FOR COLE MOTORSPORTS/CM RACING PRODUCTS ON WINDSHIELD TEAROFFS ON ¼ GLASS VTEC # TESTED: MARCH 27, 2009

ASTM E662 TESTING FOR COLE MOTORSPORTS/CM RACING PRODUCTS ON WINDSHIELD TEAROFFS ON ¼ GLASS VTEC # TESTED: MARCH 27, 2009 ASTM E662 TESTING FOR COLE MOTORSPORTS/CM RACING PRODUCTS ON WINDSHIELD TEAROFFS ON ¼ GLASS VTEC #100-3191-1 TESTED: MARCH 27, 2009 April 2, 2009 Client: Attention: Cole Motorsports/CM Racing Products

More information

UL Test Methods for Determining the Combustibility Characteristics of Plastics Used in Semiconductor Tool Construction. General Information

UL Test Methods for Determining the Combustibility Characteristics of Plastics Used in Semiconductor Tool Construction. General Information UL 2360 Test Methods for Determining the Combustibility Characteristics of Plastics Used in Semiconductor Tool Construction General Information UL 2360 - Test Methods for Determining the Combustibility

More information

PRODUCT SPECIFICATION FireMaster Plus

PRODUCT SPECIFICATION FireMaster Plus PRODUCT SPECIFICATION FireMaster Plus 1 GENERAL 1.1 Scope Coopers FireMaster Plus active fire curtain barrier assemblies ( Fire Curtains ) are to be designed, fabricated, delivered, installed and commissioned

More information

Proforma for Surveillance of Recognized Environmental Laboratory under the Environment (Protection) Act, 1986

Proforma for Surveillance of Recognized Environmental Laboratory under the Environment (Protection) Act, 1986 Ministry of Environment & Forests, New Delhi Central Pollution Control Board, Delhi Proforma for Surveillance of Recognized Environmental Laboratory under the Environment (Protection) Act, 1986 Surveillance

More information

Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirapalli , TAMIL NADU, INDIA MATERIALS MANAGEMENT / CAPITAL EQUIPMENT

Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirapalli , TAMIL NADU, INDIA MATERIALS MANAGEMENT / CAPITAL EQUIPMENT An ISO 9001 Company Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirapalli 620014, TAMIL NADU, INDIA MATERIALS MANAGEMENT / CAPITAL EQUIPMENT ENQUIRY NOTICE INVITING TENDER Phone:

More information

CEE:3371 Principles of Hydraulics and Hydrology Project #2 Flow Measurement with a Weir

CEE:3371 Principles of Hydraulics and Hydrology Project #2 Flow Measurement with a Weir CEE:3371 Principles of Hydraulics and Hydrology Project #2 Flow Measurement with a Weir Problem Statement The Iowa DNR plans to monitor a proposed prairie restoration project in eastern Iowa as an experiment.

More information