Declaration of performance ( DoP ) :
|
|
- Valerie George
- 5 years ago
- Views:
Transcription
1 Gueugnon Declaration of performance ( DoP ) : Gue Stainless steel for construction purposes EU-regulation: 305/2011 Gueugnon site / / Cold-rolled 1. Product-type: / Construction product: Cold-rolled stainless steel coils, plates, sheets according to EN : Intended use: products for internal and external use for construction purposes, building constructions or civil engineering 4. Manufacturer: Aperam Gueugnon BP1 4 Place des Forges GUEUGNON FRANCE Tel: +33 (0) gerard.ramoissenet@aperam.com Website : 5. Authorised representative: Not applicable 6. System of assessment and verification of constancy of performance: System Case of the declaration of performance concerning a construction product by a harmonized standard: TÜV SÜD Industrie Service GmbH, Nr. 0036, has performed the initial inspection of the factory and factory production control and monitoring, review and approval of the factory production control according to system 2+ and issued a conformity certificate of production control: Aperam Gueugnon: CPR - M Case of the declaration of performance concerning a construction product for which a European Technical Assessment has been issued: Not applicable DoP.Gue REV.0 (page 1 of 3)
2 9. Declared performance : characteristics Performance for Nominal Finish thickness(mm) Tolerances on dimensions and shape Yield strength (Rp 0,2%) Yield strength (Rp1%) Tensile strength Elongation Impact strength rolled EN ISO Values for max min(trans) min(long) (trans) rolled 0,3 th MPa EN rolled 0,3 th MPa EN rolled 0,3 th MPa 680MPa EN rolled 0,3 th % EN Cold rolled NPD NPD EN DoP.Gue REV.0 (page 2 of 3)
3 characteristics Performance for Weldability rolled chemical composition EN Durability rolled chemical composition EN Formability at room temperature rolled see elongation EN Values (% mass) for Chemical composition rolled C: 0,030 EN Si: 1,00 EN Mn: 2,00 EN P: 0,045 EN S: 0,015 EN N: 0,10 EN Cr: 16,5-18,5 EN Ni: 10,0-13,0 EN Mo: 2,00-2,50 EN Regulated substance rolled NPD EN The performance of the product identified in points 1 and 2 is in conformity with the declared performance in point 9. This declaration of performance is issued under the sole responsibility of the manufacturer identified in point 4. Signed for and on behalf of the manufacturer by Philippe Quere - Head SMI Gueugnon, 2014/02/07 DoP.Gue REV.0 (page 3 of 3)
4 Gueugnon Declaration of performance ( DoP ) : Gue Stainless steel for construction purposes EU-regulation: 305/2011 Gueugnon site / / Cold-rolled 1. Product-type: Construction product: Cold-rolled stainless steel coils, plates, sheets according to EN : Intended use: products for internal and external use for construction purposes, building constructions or civil engineering 4. Manufacturer: Aperam Gueugnon BP1 4 Place des Forges GUEUGNON FRANCE Tel: +33 (0) gerard.ramoissenet@aperam.com Website : 5. Authorised representative: Not applicable 6. System of assessment and verification of constancy of performance: System Case of the declaration of performance concerning a construction product by a harmonized standard: TÜV SÜD Industrie Service GmbH, Nr. 0036, has performed the initial inspection of the factory and factory production control and monitoring, review and approval of the factory production control according to system 2+ and issued a conformity certificate of production control: Aperam Gueugnon : CPR - M Case of the declaration of performance concerning a construction product for which a European Technical Assessment has been issued: Not applicable DoP.Gue REV.0 (page 1 of 3)
5 9. Declared performance: characteristics Performance for Nominal Finish thickness(mm) Tolerances on dimensions and shape Yield strength (Rp 0,2%) Yield strength(rp1%) Tensile strength Elongation Impact Strenght rolled EN ISO Values for max min(trans) min(long) (trans) rolled 0,3 th MPa EN rolled 0,3 th MPa EN rolled 0,3 th MPa 680MPa EN rolled 0,3 th % EN rolled NPD EN DoP.Gue REV.0 (page 2 of 3)
6 characteristics Performance for Weldability rolled chemical composition EN Durability rolled chemical composition EN Formability at room temperature rolled see elongation EN Values (% mass) for Chemical composition rolled C: 0,070 EN Si: 1,00 EN Mn: 2,00 EN P: 0,045 EN S: 0,015 EN N: 0,10 EN Cr: 16,5-18,5 EN Ni: 10,0-13,0 EN Mo: 2,00-2,50 EN Regulated substance rolled NPD EN The performance of the product identified in points 1 and 2 is in conformity with the declared performance in point 9. This declaration of performance is issued under the sole responsibility of the manufacturer identified in point 4. Signed for and on behalf of the manufacturer by Philippe Quere - Head SMI Gueugnon, 2014/02/07 DoP.Gue REV.0 (page 3 of 3)
See product BS EN :2010
DECLARATION OF PERFORMANCE TLX UV 10 BMTLXUV10CPR 1. Unique identification code of the product-type: TLX UV10 Breather Membrane 2. Type, batch or serial number or any other element allowing identification
More informationFor structural use in all types of construction works according to EN
DECLARATION OF PERFORMANCE 1 N 1090-10025 EN 1090-1 DoP ENG. 02 EN10025-2 1 Unique identification code of the product-type: Component(s) 2 according to EN 1090-2 following customer s specification and
More informationin accordance with Annex 111 of Regulation (EU) No. 305/2011 ( Construction Products Regulation ) ULTRA PROFLEX SP+ES GREY
DECLARATION OF PERFORMANCE in accordance with Annex 111 of Regulation (EU) No. 305/2011 ( Construction Products Regulation ) 1. Unique identification code of the product type: ULTRA PROFLEX SP+ES GREY
More informationDECLARATION OF PERFORMANCE 1 N. For structural use in all types of construction works according to EN
DECLARATION OF PERFORMANCE 1 N EN 1090-1 DoP ENG. 03 EN10210-2 1 Unique identification code of the product-type: Component(s) 2 according to EN 1090-2 following customer s specification and produced out
More informationDECLARATION OF PERFORMANCE. DoP: 0135 for fischer injection system FIS EM Plus (Bonded anchor for use in concrete) EN
DECLARATION OF PERFORMANCE DoP: 0135 for fischer injection system FIS EM Plus (Bonded anchor for use in concrete) EN 1. Unique identification code of the product-type: DoP: 0135 2. Intended use/es: Post-installed
More informationDECLARATION OF PERFORMANCE
EN 15651-1:2012 EN 15651-2:2012 14 1119 DECLARATION OF PERFORMANCE Sikasil WS-605 S 01 26 03 01 011 9 001000 1024 1. Product Type: Unique identification code of the product-type: 2. Type batch or serial
More informationDECLARATION OF PERFORMANCE. No EN
DECLARATION OF PERFORMANCE No. 0021 EN 1. Unique identification code of the product-type: Rebar connection with fischer injection mortar FIS EM 2. Intended use/es: Product Mortar for post-installed rebar
More informationDECLARATION OF PERFORMANCE. DoP: 0094 for Injection System fischer FIS V (Bonded anchor for use in concrete) EN
DECLARATION OF PERFORMANCE DoP: 0094 for Injection System fischer FIS V (Bonded anchor for use in concrete) EN 1. Unique identification code of the product-type: DoP: 0094 2. Intended use/es: Post-installed
More informationDECLARATION OF PERFORMANCE. No EN. Annexes B 1 to B 4
DECLARATION OF PERFORMANCE No. 0069 EN 1. Unique identification code of the product-type: fischer drop-in anchor EA II 2. Intended use/es: Product Metal anchors for use in concrete (heavy-duty type) Intended
More informationDECLARATION OF PERFORMANCE. No EN
DECLARATION OF PERFORMANCE No. 0072 EN 1. Unique identification code of the product-type: Injection System fischer FIS V 2. Intended use/es: Product Bonded anchor for use in concrete Intended use/es For
More informationDECLARATION OF PERFORMANCE
Flooring Declaration of Performance Edition 01.07.2013 Identification no. Version no. 01 EN 1504-2: 2004 13 0921 EN 13813: 2002 DECLARATION OF PERFORMANCE Declaration of performance 1. Product Type Unique
More informationDECLARATION OF PERFORMANCE. No EN
DECLARATION OF PERFORMANCE No. 0079 EN 1. Unique identification code of the product-type: fischer injection system FIS EM 2. Intended use/es: Product Metal anchors for use in concrete (heavyduty type)
More informationImplementation of the Construction Products Regulation (CPR) in harmonized standards - Template for Annex ZA -
TF N 530 Rev.2 2012-04-13 CONSTRUCTION SECTOR STANDARDIZATION GUIDANCE DOCUMENT Implementation of the Construction Products Regulation (CPR) in harmonized standards - Template for Annex ZA - 1 Drafting
More informationDeclaration of Performance
EN 1504-2:2004 09 0866 EN 13813 EN 1504-2:2004 DECLARATION OF PERFORMANCE 264 1. Product Type: Unique identification code of the product-type: 2. Type batch or serial number or any other element allowing
More informationDECLARATION OF PERFORMANCE. No EN
DECLARATION OF PERFORMANCE No. 0085 EN 1. Unique identification code of the product-type: fischer Highbond-Anchor FHB 2. Intended use/es: Product Bonded anchor for use in concrete Intended use/es Anchorages
More informationCONSTRUCTION PRODUCTS REGULATION 2011 DECLARATION OF PERFORMANCE
Page 1 of 4 CONSTRUCTION PRODUCTS REGULATION 2011 DECLARATION OF PERFORMANCE DoP Number: HUK0022 1. Unique identification code of the product-type: AR880 Series Panic Bolt, AR882 Series Reversible Panic
More informationDeclaration of Conformity Declaration of Performance Notes
What difference is there in the information to be included in the Declaration of Performance under the CPR (as updated by Delegated Act (EU) No. 574/2014) from that currently provided in the Declaration
More informationCONSTRUCTION PRODUCTS REGULATION 2011 DECLARATION OF PERFORMANCE
Page 1 of 4 CONSTRUCTION PRODUCTS REGULATION 2011 DECLARATION OF PERFORMANCE DoP Number: AS3002 AS3012 AS3052 1. Unique identification code of the product-type: AS3002 SIZE 1-6 OVERHEAD DOOR CLOSER SE
More informationF O C U S D O O R C L O S E R S
(3) - Door Closers.qxp_(3) - Door Closers Art 14/02/2014 16:14 Page 2 F O C U S D O O R C L O S E R S KD.915 With cover Successfully Tested to EN 1154 4 8 5 1 1 3 2 Adjustable 2 to 5 by Spring Closer opening
More informationDECLARATION OF PERFORMANCE
Flooring Declaration of Performance Edition 01.07.2013 Identification no. Version no. 01 EN 1504-2: 2004 08 0921 EN 13813: 2002 DECLARATION OF PERFORMANCE Declaration of performance 1. Product Type Unique
More informationIntroduction. Declaration of performance (DoP) CE marking
Introduction This guide has been written to help users and specifiers of wood based panels to understand the documentation and labelling that should accompany (on a website, e-mail or physically) wood
More informationDECLARATION OF PERFORMANCE. DoP: 0124 for fischer Ceiling Anchor FDZ (Metal anchors for use in concrete (light-duty type)) EN
DECLARATION OF PERFORMANCE DoP: 0124 for fischer Ceiling Anchor FDZ (Metal anchors for use in concrete (light-duty type)) EN 1. Unique identification code of the product-type: DoP: 0124 2. Intended use/es:
More informationEN :2012 EN :2012 ETAG 026 part 3:2011 DECLARATION OF PERFORMANCE. Sikasil -670 Fire
EN 15651-1:2012 EN 15651-4:2012 ETAG 026 part 3:2011 14 1104 DECLARATION OF PERFORMANCE Sikasil -670 Fire 02 05 14 03 0000 000 106 1. Product Type: Unique identification code of the product-type: 2. Type
More informationDECLARATION OF PERFORMANCE. No EN. Post-installed fastening in cracked or uncracked concrete, see appendix, especially Annexes B 1 to B 9
DECLARATION OF PERFORMANCE No. 0019 EN 1. Unique identification code of the product-type: fischer Highbond-Anchor FHB II 2. Intended use/es: Product Bonded anchor for use in concrete Intended use/es Post-installed
More information1. Terms defined in the Construction Products Regulation (CPR)
CEN/TC 351 Glossary of relevant terms related to the CPR The following list of terms provides definitions of terms related to the CPR (EU/305/2011) which are relevant for the work of CEN/TC 351 Construction
More informationDECLARATION OF PERFORMANCE. No EN
DECLARATION OF PERFORMANCE No. 0048 EN 1. Unique identification code of the product-type: fischer frame fixing SXR/SXRL 2. Intended use/es: Product Plastic anchors for use in concrete and masonry Intended
More informationDECLARATION OF PERFORMANCE
Flooring Declaration of Performance Edition 01.07.2013 Identification no. Version no. 01 EN 1504-2: 2004 08 0921 EN 13813: 2002 DECLARATION OF PERFORMANCE Declaration of performance 1. Product Type Unique
More informationDECLARATION OF PERFORMANCE
DECLARATION OF PERFORMANCE DoP: 0063 for Upat Drop-in Anchor USA (Metal anchors for use in concrete (light-duty type)) EN 1. Unique identification code of the product-type: DoP: 0063 2. Intended use/es:
More informationDECLARATION OF PERFORMANCE
Edition 05.2014 Identification no. 02 08 02 02 001 0 000017 Version no. 02 EN 1504-2: 2004 EN 13813: 2002 13 0086 DECLARATION OF PERFORMANCE Sikafloor -24 PurCem EN 13813:2002 02 08 02 02 001 0 000017
More informationDECLARATION OF PERFORMANCE ref. no
VALENTA ZT s.r.o. Nedomická 494, 277 16 Všetaty tel. (+420) 315 698 020 www.zavitovetyce.cz IČO: 26512149 fax. (+420) 315 696 868 prodej@valentazt.cz DIČ: CZ26512149 DECLARATION OF PERFORMANCE ref. no.
More informationDeclaration of Performance
DOPS for N300 / H350 / N500 / N700 Declaration of Performance STYROZONE N300 / H350 / N500 / N700 1000.CPR.2013.Styrozone.001 1. Unique identification code of the product-type 2. Type, batch or serial
More informationDECLARATION OF PERFORMANCE. No EN. Post-installed fastening in cracked or uncracked concrete, see appendix, especially Annexes B 1 to B 4
DECLARATION OF PERFORMANCE No. 0081 EN 1. Unique identification code of the product-type: fischer Bolt Anchor FAZ II 2. Intended use/es: Product Torque controlled expansion anchor Intended use/es Post-installed
More informationFiretect C. Fire protective products: Fire protective board
European Technical Assessment ETA-14/0293 Of /0 /201 Trade name of the construction product Product family to which the construction product belongs Manufacturer Manufacturing plants This European Technical
More informationDECLARATION OF PERFORMANCE. No EN
DECLARATION OF PERFORMANCE No. 0017 EN 1. Unique identification code of the product-type: fischer Concrete screw FBS, FBS A4 and FBS C 2. Intended use/es: Product Metal anchors for use in concrete (heavyduty
More informationINSPECTION REPORT Nr IDD/S-09/922
Page: 1/7 PROJECT: TPI For Sheet Pile BV Client: Manufacturer: Nanjing Grand Steel Piling Co., Ltd. Inspection requested by: Ref: P/o nr: (client to BV) P/o nr: GP09111101 (client to Manufacturer) SUPPLY
More informationGuideline Construction Products Regulation (EU) 305/20122
Guideline Construction Products Regulation (EU) 305/20122 Guideline: CPR 1 Table of contents Common Abbreviations... 4 Executive Summary... 5 Purpose of this guidance document... 5 Summary Requirements
More informationDECLARATION OF PERFORMANCE. No EN. Post-installed fastening in cracked or uncracked concrete, see appendix, especially Annexes B 1 to B 6
DECLARATION OF PERFORMANCE No. 0020 EN 1. Unique identification code of the product-type: fischer High-Performance Anchor FH II, FH II-I 2. Intended use/es: Product Torque controlled expansion anchor Intended
More informationYour Key to achieving C.E Marking Compliance
Your Key to achieving C.E Marking Compliance As of the 1 st July 2013 The Construction Products Regulation 2011 contains clauses relating to C E marking of products. This will therefore mean that a CE
More informationGuidance Note No 21/1. CE Marking Windows and doorsets to BS EN 16034
Guidance Note No 21/1 CE Marking Windows and doorsets to BS EN 16034 Introduction CE Marking of construction products has been a legal requirement since July 2013. It is a European requirement for all
More informationDID YOU GET USED TO THE NEW CPR? HERE S A QUICK REVIEW!
June 2018 DID YOU GET USED TO THE NEW CPR? HERE S A QUICK REVIEW! How to recognize compliant cables? The new CPR defines the rules and the requirements of construction products to be manufactured, distributed
More informationDECLARATION OF COMPLIANCE PERFORMANCE AND CE MARK
DECLARATION OF COMPLIANCE PERFORMANCE AND CE MARK Declaration only valid with the purchase invoice for the said product, which indicates the quantity of l./kg acquired, data that will determine approx.
More informationbest practice guide Pedestrian doorsets Fire resisting and/or smoke control characteristics - to
best practice guide Pedestrian doorsets Fire resisting and/or smoke control characteristics - to BS EN 16034: 2014 Permission to reproduce extracts from BS EN 16034 : 2014 is granted by BSI. DHF BEST PRACTICE
More informationLawnmowers, pedestrian controlled (combustion engine powered)
Compliance Guide Rev.1, 09/2016 Lawnmowers, pedestrian controlled (combustion engine powered) European Garden Machinery Federation EGMF Bd Reyers 80, 1030 Brussels, Belgium secretariat@egmf.org +32 2 206
More informationCylinder Mortice Dead lock Lockcase(mm) A=87 Backset (mm) B=55. Follower (mm) 8 Latch Bolt
Product ID: KL.1902 Name: Cylinder Mortice Dead lock Lockcase(mm) A=87 Backset (mm) B=55 Centres C=N/A Follower (mm) 8 Latch Bolt N/A Mechanism Euro- Profile Forend Finish SSS Rebates available (mm) KL.1902A
More informationEuropean Technical Assessment. ETA-13/0136 of 20 March English translation prepared by DIBt - Original version in German language.
European Technical Assessment ETA-13/0136 of 20 March 2018 - Original version in German language General Part Technical Assessment Body issuing the European Technical Assessment: Trade name of the construction
More informationCONSTRUCTION PRODUCTS REGULATION MOLEX CES COPPER AND FIBRE CABLE
CONSTRUCTION PRODUCTS REGULATION MOLEX CES COPPER AND FIBRE CABLE Carol Harris, EMEA Product Manager WHITE PAPER Molex Connected Enterprise Solutions EXECUTIVE SUMMARY Combustible construction materials
More informationSystem Solutions. Quick and simple to construct. Range of partitions. Fully warranted systems. CE Marked. Knauf CE Marking. A guide to CE marking
System Solutions Quick and simple to construct Range of partitions Fully warranted systems CE Marked Knauf CE Marking A guide to CE marking CE Marking From 1 July 2013 the Construction Products Regulation
More informationRegulation 574_2014: Annex III CPR. and. Regulation 568_2014: Annex V CPR
TF N 635 Regulation 574_2014: Annex III CPR and Regulation 568_2014: Annex V CPR 30-05-2014 28.5.2014 L 159/41 REGULATIONS COMMISSION DELEGATED REGULATION (EU) No 574/2014 of 21 February 2014 amending
More informationFire damper ETPR Instructions for Installation, Operation and Maintenance 10/2016
Instructions for Installation, Operation and aintenance 10/2016 Installation Fire damper ETPR must be installed according to this installation manual, see pages 2-5. Operation and function testing According
More informationSD119 Range of Conventional Smoke and Smoke/Heat Detectors (refer to attached appendix for details and conditions)
In compliance with Regulation 305/2011/EU of the European Parliament and of the Council of 9 March 2011 (the Construction Products Regulation), this certificate applies to the construction product(s).
More informationImplementation of the Construction Products Regulation (CPR) in harmonized standards - Template for Annex ZA -
TF N 687rev1 2015-06-02 CONSTRUCTION SECTOR STANDARDIZATION GUIDANCE DOCUMENT Implementation of the Construction Products Regulation (CPR) in harmonized standards - Template for Annex ZA - 1 I - Drafting
More informationYOUR GUIDE TO UNDERSTANDING CPR
YOUR GUIDE TO UNDERSTANDING CPR WITH EXCEL NETWORKING SOLUTIONS ISSUE 2 UPDATED JANUARY 2018 WWW.EXCEL-NETWORKING.COM CONTENTS What is CPR? When will this happen? Why the update? Which products are affected?
More informationGuidance Note No 19/1. CE Marking windows and doorsets
Guidance Note No 19/1 CE Marking windows and doorsets What is CE marking? The CE marking of products in the European Union is used by manufacturers to indicate that their products conform to requirements
More informationEN transition from BS 1387 Structural & Conveyance Business
Corus Tubes EN 10255 transition from BS 1387 Structural & Conveyance Business EN 10255 A smooth transition with Corus Install Contents 1 Introduction 2 The new standard 4 Detailed comparison 7 Comparison
More informationEN Медь и медные сплавы Бесшовные круглые медные трубы для воды и газа для применения в санитарных целях и отоплении.
Contents Page Foreword...4 Introduction...6 1 Scope...7 2 Normative references...7 3 Terms and definitions...8 4 Designations...9 4.1 Material...9 4.1.1 General...9 4.1.2 Symbol...9 4.1.3 Number...9 4.2
More informationCE marking of industrial doors under the CPR Michael Skelding, Secretary and General Manager Door and Hardware Federation
CE marking of industrial doors under the CPR 2011 Michael Skelding, Secretary and General Manager Door and Hardware Federation Who is the DHF? DHF represents manufacturers & installers of: Pedestrian doors
More informationHot rolled flat products made of high yield strength steels for cold forming
ÖNORM EN 10149-2 Edition: 2013-11-01 Hot rolled flat products made of high yield strength steels for cold forming Part 2: Technical delivery conditions for thermomechanically rolled steels Warmgewalzte
More informationCOMMISSION DELEGATED REGULATION (EU)
28.5.2014 L 159/41 REGULATIONS COMMISSION DELEGATED REGULATION (EU) No 574/2014 of 21 February 2014 amending Annex III to Regulation (EU) No 305/2011 of the European Parliament and of the Council on the
More informationCPR Guide: EU Rules Practical Impact
CPR Guide: EU Rules Practical Impact December 2015 Glass for Europe is the trade association for Europe s manufacturers of flat glass. Flat glass is the material that goes into a variety of end products
More informationThe Danish Energy Agency will carry out inspections in June 2013
Table of Contents The Danish Energy Agency will carry out inspections in June 2013... 2 What is CE marking of a construction product?... 3 Where can you find the requirements for CE marking of wood flooring?...
More informationGNB-CPR Position Paper: Issuance of certificates under CPR
GNB-CPR AG Co-ordination of the Group of Notified Bodies for the Construction products Regulation (EU) No 305/2011 NB-CPR/14-612r7 Issued: 18 August 2016 APPROVED GUIDANCE GNB-CPR Position Paper: Issuance
More informationImplementation of Harmonized Standards - A Member State Perspective. Norway
Implementation of Harmonized Standards - A Member State Perspective Norway Matteo Pezzucchi Senior Engineer, Norwegian Public Roads Administration Introduction Implementation of Harmonized Standards CE
More informationCPR Guide: EU Rules Practical Impact
CPR Guide: EU Rules Practical Impact December 2015 About Glass for Europe Glass for Europe is the trade association for Europe s flat glass sector. Flat glass is the material that goes into a variety of
More informationCE marking of fire-resistant doors the right way!
Page 1 of 5 ift Rosenheim CE marking of fire-resistant doors the right way! Surveillance and certification of fire safety products 1 Introduction The product standard for doors, gates and windows with
More informationReview of reports and data for Aero-Therm thermal reflective coating. Prepared for: Mr Craig Clement Director
Review of reports and data for Aero-Therm thermal reflective coating Prepared for: Mr Craig Clement Director Aero-Therm Products Limited Riverside Jubilee Way Wakefield WF4 4TD 17 th September 2015 Report
More informationDomestic Garage Doors
Domestic Garage Doors Guidance for enforcement bodies www.dhfonline.org.uk Contents About dhf 1 Applicable legislation & standards 2 Annex A 5 Annex B 11 Useful links 13 About dhf dhf represents the key
More informationEuropean Technical Assessment ETA-14/0176
British Board of Agrément Bucknalls Lane Watford Herts WD25 9BA Tel: + 44 (0) 1923 665300 Fax: + 44 (0) 1923 665301 e-mail: mail@bba.star.co.uk website: www.bbacerts.co.uk Designated according to Article
More informationThe New EU-Regulation on Construction Products
The New EU-Regulation on Construction Products Dr. Rainer Mikulits Managing Director Austrian Institute of Construction Engineering (OIB) IRCC Meeting 12-14 May 2010, Tokyo, Japan Contents European Construction
More informationCERTIFICATE. Conformity of the Factory Production Control CPR TÜVRh
CERTIFICATE Conformity of the Factory Production Control 0035-CPR-1090-1.00794.TÜVRh.2017.003 In compliance with Regulation 305/2011/EU of the European Parliament and of the Council of 9 March 2011 (the
More informationFrequently Asked Questions on the Construction Products Regulation (CPR) - Enterprise and Industry
1. Must a construction product bear the CE marking after 30/06/2013? After 30/06/2013, in order to sell a construction product in the European Union (EU) the manufacturer has the obligation to issue a
More informationEU Declaration of Conformity
16 May 2017 EU Declaration of Conformity Model Number: ET1215L Series Equipment Category: Information Technology and Telecommunications Equipment Equipment Class: Commercial and Light Industrial Product
More informationWhite paper. Construction Product Regulations* by Multimedia Connect. Which cables are concerned by these new regulations?
White paper by Multimedia Connect Construction Product Regulations* We are all concerned by the safety of persons and property. In 2010, 8 million fires were recorded: they are estimated to have caused
More informationCE marking of noise barriers and foundations
CE marking of noise barriers and foundations Date 2 June 2014 Case officer Charlotte Sejr E - mail cslp@vd.dk Phone +45 7244 2340 Document 14/10726-2 Page 1/13 1 Table of Contents CE MARKING OF NOISE BARRIERS...
More informationSchedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK
2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 4ward Ltd 5 Hampers Common Industrial Estate Petworth West Sussex GU28 9NR Contact: Ms Lesley Komatsu Tel: +44 (0)1798-342240 Fax: +44 (0)1798-344482
More informationGlass fibre rovings - Non-metallic materials
CLASS PROGRAMME Type approval DNVGL-CP-0082 Edition December 2015 The electronic pdf version of this document, available free of charge from http://www.dnvgl.com, is the officially binding version. FOREWORD
More informationCoatings for protection of FRP structures with heavy rain erosion loads
CLASS PROGRAMME Type approval DNVGL-CP-0424 Edition May 2016 Coatings for protection of FRP structures with heavy rain erosion loads The content of this service document is the subject of intellectual
More informationÜntel is ready for CPR
2016 Üntel is ready for CPR Hakan Kubas Marketing Manager 01.11.2016 Construction Products Regulation What is the CPR? The Construction Products Regulation (CPR) lays down conditions for the placing or
More informationCEN standardization work on refrigerating systems, especially standard EN 378
CEN standardization work on refrigerating systems, especially standard EN 378 Carsten Hoch Head of Refrigeration TÜV SÜD Industrie Service GmbH Ridlerstrasse 65, 80339 Munich carsten.hoch@tuev-sued.de
More informationTechnical Bulletin CE marking: from 1st July 2013
Technical Bulletin CE marking: from 1st July 2013 New regulation New obligations Same CE mark We are facing the most significant change for a decade in the way that construction products are manufactured
More informationCE-marked ESAD - Smoke Control Duct System Installation instructions 08/2013
CE-marked ESAD - Smoke Control Duct System Installation instructions 08/2013 ESAD Smoke Control Duct System INSTALLATION INSTRUCTIONS 1.0 Installation of smoke control ducts, general quidelines Smoke Control
More informationElectrical test. Determining resistance of conductors by means of using DC four-wire connection measurement
Nr. Material or Product Type of activity Internal reference number 1 Cables of rated voltage up to Electrical test Determining resistance of conductors by means of using DC four-wire connection measurement
More informationLeadax B.V. Covenant K93792/02. Leadax
561/170522 Covenant K93792/02 Uitgegeven 2017-12-01 Vervangt K93792/01 Pagina 1 of 5 VERKLARING VAN KIWA With this Covenant, issued in accordance with the Kiwa Regulations for Product Certification, Kiwa
More informationPARKERSTEEL Vauxhall Road, Canterbury, Kent CT1 1HD
PARKERSTEEL Vauxhall Road, Canterbury, Kent CT1 1HD Telephone: 01227 783333 Fax: 0800 521932 E-mail: Sales@Parkersteel.co.uk Steel Stockholders Distributors to Industry Dear Sirs / To Whom it may concern
More informationSpecification for Road Works Series Introduction
Specification for Road Works Series 000 - CC-SPW-00010 March 2015 CC Construction & Commissioning Standards TRANSPORT INFRASTRUCTURE IRELAND (TII) PUBLICATIONS About TII Transport Infrastructure Ireland
More informationSchedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK
2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Chatsworth Technology Park Dunston Road Chesterfield Derbyshire S41 8XA Contact: Mr M Watson Tel: +44 (0)1246 263861 Fax: +44 (0)1246 260919
More informationEuropean Technical Assessment. ETA-10/0255 of 22 August General Part. Technical Assessment Body issuing the European Technical Assessment:
European Technical Assessment ETA-10/0255 of 22 August 2014 General Part Technical Assessment Body issuing the European Technical Assessment: Trade name of the construction product Product family to which
More informationBrush cutters Grass Trimmers (combustion engine powered)
Compliance Guide Rev.1, 09/2016 Brush cutters Grass Trimmers (combustion engine powered) European Garden Machinery Federation EGMF Bd Reyers 80, 1030 Brussels, Belgium secretariat@egmf.org +32 2 206 68
More informationEU Declaration of Conformity
22 May 2017 EU Declaration of Conformity Model Number: ETT10I1 Series Equipment Category: Information Technology and Telecommunications Equipment Equipment Class: Commercial and Light Industrial Product
More informationThe New Generationn of Firedoors
The New Generationn of Firedoors Product Standard EN 16034 Introduction A modern company, while operating in mature sectors, is actually part of an ncreasingly technocratic world, influenced by technical,
More informationMechanically operated locks and locking plates
Mechanically operated locks and locking plates to BS EN 12209:2016 www.dhfonline.org.uk 01 dhf Best Practice dhf Best Practice : Mechanically operated locks and locking plates to BS EN 12209:2016 dhf Best
More informationEuropean Technical Assessment. ETA-14/0269 of 13 October General Part. Technical Assessment Body issuing the European Technical Assessment:
European Technical Assessment ETA-14/0269 of 13 October 2014 General Part Technical Assessment Body issuing the European Technical Assessment: Trade name of the construction product Product family to which
More informationDIN, EN, ASTM. Металлопрокат и трубы по стандартам. Поставляем металлопрокат по стандарту EN
Металлопрокат и трубы по стандартам DIN, EN, ASTM Поставляем металлопрокат по стандарту EN 14399-1 Для заказа металлопроката или получения консультации обращайтесь по следующим контактам: Россия: +7 (495)
More informationReaction to fire classification report No C-rev.1
Reaction to fire classification report. 17241C-rev.1 Owner of the classification report Distributor: Vescom bv Churchilllaan 10 Sint Jozefstraat 20 5705 BK Helmond 5750 AB Deurne The Netherlands The Netherlands
More informationSchedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK
2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Issue No: 035 Issue date: 23 February 2017 16 Abbotsinch Road Grangemouth FK3 9UX Contact: Mr G Falconer Tel: +44 (0)1324 489182 Fax: +44
More informationWindow and Door Standards for Performance and Security. Russell Day Senior Technical Officer Glass and Glazing Federation
Window and Door Standards for Performance and Security Russell Day Senior Technical Officer Glass and Glazing Federation The Standards BS EN 14351-1:2006+A2:2016 Windows and doors. Product standard, performance
More informationThe effects on the UK Fire Industry. Paul Pope Eng.Tech AIFireE
The effects on the UK Fire Industry Paul Pope Eng.Tech AIFireE Content Introduction to the issues, specifically: - The EU Construction Products Regulation (CPR) EU Notified Body role in CPR certification
More informationEuropacable FAQ on CPR Status: 26/01/17
Europacable FAQ on CPR Status: 26/01/17 DISCLAIMER This FAQ document reflects the best knowledge of industry experts across Europe and the state of the art at the time of writing (July 2016). It represents
More informationLawnmowers (pedestrian controlled electric mains-powered)
Compliance Guide Rev.2, Edition 04/2018 Lawnmowers (pedestrian controlled electric mains-powered) European Garden Machinery Federation EGMF Bd Reyers 80, 1030 Brussels, Belgium secretariat@egmf.org +32
More informationAdditional reaction to fire classification report No H
Additional reaction to fire classification report. 12700H Owner of the additional classification report Antalis International 8 Rue de Seine 92517 Boulogne Billancourt Cedex France Introduction This additional
More informationThis annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation
nnex to declaration accreditation (scope accreditation) egistration number: L 015 This annex is valid from: 01-08-2018 to 01-09-2020 eplaces annex dated: 21-03-2018 Location(s) where activities are performed
More information