Control Of Points. Withdrawn Document Uncontrolled When Printed. Railway Group Standard. Issue One Date July 1997

Size: px
Start display at page:

Download "Control Of Points. Withdrawn Document Uncontrolled When Printed. Railway Group Standard. Issue One Date July 1997"

Transcription

1 Date July 1997 Signatures removed from electronic version Submitted by... Richard Genner Nominated Responsible Manager Approved by... Philip Wiltshire Chairman, Train Control & Communications Subject Committee Approved by... Michael Harwood Chairman, Operations Standards Subject Committee Authorised by Synopsis: This standard sets out the principles for the control of points by the signalling system. This document is the property of Railtrack PLC. It shall not be reproduced in whole or in part without the written permission of the Controller, Safety Standards, Railtrack PLC. Published by Safety & Standards Directorate Railtrack PLC Floor 2, Fitzroy House 355 Euston Road London NW1 3AG Copyright 1997 Railtrack PLC R Illingworth... for Dr M Walter Controller, Safety Standards

2 This page is intentionally blank

3 Date July1997 Page 1 of 8 Contents Description Page Part A Part B Issue record 2 Responsibilities 2 Compliance 2 Health and Safety Responsibilities 2 Supply 2 1 Purpose 3 2 Scope 3 3 Definitions 3 4 General Requirements 4 5 Requirements for Manual Operation of Power Worked Points 6 6 Equipment Performance Requirements 6 7 New and Redundant Points 7 References 8 R A I L T R A C K 1

4 Date July 1997 Page 2 of 8 Part A Issue record Responsibilities This standard will be updated when necessary by distribution of a complete replacement. Amended or additional parts of revised pages will be marked by a vertical black line in the adjacent margin. Issue Date Comments One July 1997 This standard supersedes SSP26 paragraphs 1, 2 and 3; GS/ST0081 paragraph s are mandatory on all members of the Railway Group* and apply to all relevant activities which fall within the scope of each individual s Railway Safety Case. If any of those activities are performed by a contractor, the contractor s obligation in respect of s is determined by the terms of the contract between the respective parties. Where the contractor is himself a duty holder of a Railway Safety Case then s apply directly to the activities described in his Railway Safety Case. *The Railway Group comprises Railtrack and the duty holders of Railway Safety Cases accepted By Railtrack Compliance Health and Safety Responsibilities Supply The provisions of this are mandatory for design and implementation work undertaken on schemes for which the Signalling Scheme Plan is approved on or after 7th February Retrospective action is not required in respect of existing layouts and Signalling Scheme Plans approved prior to 7th February Railtrack shall consider the need to meet the provisions of this standard for alterations effected on or after 7th February 1998 to Signalling Scheme Plans approved prior to 7th February Section 5, paragraph 3 shall not prevent new installations of an existing type of electro-pneumatic point machine which may currently disconnect the detection by means of a key. In authorising this standard, Railtrack PLC makes no warranties, express or implied, that compliance with all or any of Railway Group Standards is sufficient on its own to ensure safe systems of work or operation. Each user is reminded of its own responsibilities to ensure health and safety at work and its individual duties under health and safety legislation. Controlled and uncontrolled copies of this standard must be obtained from the Catalogue Secretary, Railtrack Safety & Standards Directorate, Floor 2, Fitzroy House, 355 Euston Road, London NW1 3AG. Telephone: Facsimile: or (BT) or (BT) 2 R A I L T R A C K

5 Date July1997 Page 3 of 8 Part B 1 Purpose To define the requirements for the control of points by the signalling system to ensure the safe movement of trains. 2 Scope This standard applies to all point ends whose position is detected by the signalling system, whose movement is controlled or supervised by the signalling system, or whose operation is supervised by a signaller, including ground frames. Provision for manual operation of power worked points is also included. Train Operated Points are excluded from this standard and are the subject of, GK/RT0065. This standard relates to the control of points in the required position and detection and indication of the state of those points. The standard does not deal with the functionality of the mechanism to achieve this. Internal interlocking controls are specified in Railway Group Standard GK/RT0060. Although the safety of points depends also on the construction of the permanent way, this standard is confined to those factors which affect the signalling system. 3 Definitions Points: The items of permanent way which may be aligned to one of two positions, normal or reverse, according to the direction of train movement required. For the purpose of this standard the term points includes moveable items of permanent way such as separate switch rails, coupled switch rails, switch diamonds, swing nose crossings, derailers or scotch blocks, but excludes moveable items such as swing bridges. Point End: For the purpose of this standard the term includes a moveable item of permanent way such as a separate switch rail, a pair of coupled switch rails, one half of a switch diamond, a swing nose crossing, a derailer or a scotch block but excludes a moveable item such as a swing bridge. Normal and Reverse: The two defined states of a point end or associated controlling device. The determination of the normal (and hence reverse) position is arbitrary, usually defined by some convention at Signalling Scheme Plan development. Typical conventions define normal as being for the use or protection of the most used route or of the highest speed route. Correspondence: Correspondence occurs when the detected position of relevant point ends matches the normal or reverse position of the controlling device. Out of Correspondence: The term used to describe points which are not in correspondence. Detection: The proof of the position of the points, normal or reverse, to the interlocking equipment. R A I L T R A C K 3

6 Date July 1997 Page 4 of 8 Split Detection: The proof and indication to the interlocking of the position of multiple-ended sets of points, individually for each point end. External Command: An instruction sent to the point mechanism by the interlocking to send the point ends to the normal or reverse position. 4 General Requirements 4.1 Integrity Equipment integrity levels shall be appropriate to the risks associated with train movements, traversing or protected by the points. This specifically includes:- the movement of points the locking of points the detection of the switch rails relative to the stock rails the transmission of commands from the interlocking the transmission of detection information to the interlocking associated monitoring and diagnostic systems This integrity level of the point equipment (and its reliability) shall additionally apply to the equipment when not connected to the signalling system. 4.2 Operation All points, except hand points and spring points, shall be controlled to the normal or the reverse position. The point operating mechanism shall only move in response to an external command. The point operating mechanism shall move all moveable track components necessary for the safe passage of trains. The point operating mechanism shall maintain all moveable track components in the required position during the passage of a train. When the points are in either the normal or reverse position, the open switch rail shall provide adequate clearance for wheel flanges. The clearance for wheel flanges and the correct rail gauge shall be maintained throughout the length of the switch rail and, where necessary, a supplementary operating mechanism(s) shall be provided. 4.3 Facing Point Locking The point operating mechanism shall include a facing point lock, or other similar device, to physically lock the switch rails in position. Derailers, scotch blocks and hand points are excluded from this requirement. On other than running lines and for mechanical installations on running lines, where it can be demonstrated that the risk of derailment is negligible the facing point lock may be omitted. 4 R A I L T R A C K

7 Date July1997 Page 5 of 8 There shall be a means of securing the points to the position to which they are controlled and an indication to the signalman that the points are in the controlled position. 4.4 Detection Normal or reverse detection shall be mechanically proved or shall be electrically indicated to the signalling system when all components of the relative point ends are in the controlled position. Mechanical proving is only permitted where there is mechanical operation of the points and also mechanical operation of any facing direction signals, for further detail see the detection chart in section 5 of GK/RT0039. Normal or reverse detection shall only be proved or indicated when the open switch rail provides adequate clearance for wheel flanges. Where a facing point lock or similar device is provided, detection shall only be proved when the point lock is engaged (ie. points locked). Except for mechanical signalling (i.e. control by mechanical interlocking), the detection shall only be effective if it is in correspondence with the controlling devices. For mechanical signalling, correspondence requirements are specified in section 5 of GK/RT Unified Control All point ends shall be configured in such a way as to maximise reliability and safety under normal and degraded operation. The interlocking shall command the two point ends of a switch diamond to operate together and a swing nose crossing to operate with its associated switch rails unless the risks of not so doing are fully controlled. The signalman s control shall be from a single device. Other point ends may be operated together where there is an advantage in doing so (e.g. simplification of interlocking, economy of control equipment). In such cases, the signalman's control shall be from a single device and where an indication is necessary, a comprehensive indication (combined with additional point ends or as part of a split detection system) shall be provided. When it is intended to combine point ends, consideration shall be given to any secondary hazards arising from equipment failure. Point ends that are operated together can have a split detection system to facilitate train movements when there is a partial failure, but subject to the above restriction on switch diamonds and swing nose crossings. The detection system shall not be split into more than two parts. When there is a failure (total or part) of a split detection indication, train movements shall be restricted in accordance with the Rule Book requirements by the signalbox instructions. R A I L T R A C K 5

8 Date July 1997 Page 6 of Other Requirements Point operating mechanisms (all types) shall include a means of manually securing both open and closed switch rails on site, once operated, with a minimum amount of additional equipment. A padlocking facility shall also be available. Derailers and scotch blocks shall have equivalent facilities. It shall be possible to regain correspondence after such correspondence has been lost e.g. power worked points should continue to be operable after being manually worked. The list of references identifies s containing related or additional requirements. 5 Requirements for Manual Operation of Power Worked Points Facilities shall be provided to permit manual operation of point ends, independently of the power source and commands from the interlocking. Enabling of manual operation shall disconnect the point end(s) from the power source. Further power operations by the interlocking shall be prevented until the points operator has operated a reset or reconnection device. For electro-pneumatic points, it is additionally permitted to disconnect the interlocking commands and locally operate the point end(s) from the pressurised air supply. Selection of manual operation of points shall not disconnect the means of communication of detection to the interlocking. Control equipment for manual operation shall be secured such that access to control devices is available only to authorised persons. Control equipment for manual operation shall be positioned such that, where practicable, it can be operated from a position of safety and accessed without exposure to the hazards of passing trains or exposed electrical conductors. Within these constraints the control equipment should be sited as close to the switch rail toes as is practicable. 6 Equipment Performance Requirements As far as practicable, all failure modes which present an unacceptable risk to train movements shall result in a loss of correspondence. Point operation and detection mechanisms shall be designed to operate safely and reliably under all credible operating conditions of vibration, temperature, precipitation and environmental pollution without specific adjustment. The operation time of all point operating mechanisms shall be compatible with the signalling system. 7 New and Redundant Points Points, whether facing or trailing, shall be installed so that there is the minimum delay in connecting them to the signal box or ground 6 R A I L T R A C K

9 Date July1997 Page 7 of 8 frame. Similarly, redundant points shall be removed as quickly as possible after disconnection from the signal box or ground frame. The interval between installation and connection or disconnection and removal shall not normally exceed six months. Where points are not connected to the control system (e.g. as a result of alterations), Railtrack shall make arrangements for the integrity of the railway to be maintained. R A I L T R A C K 7

10 Date July 1997 Page 8 of 8 References GK/RT0009 Identification of Signalling and Related Equipment GK/RT0039 Semaphore and Mechanical Signalling GK/RT0060 Interlocking Principles GK/RT0061 Shunters Releases. Ground Frames, Switch Panels and Gate Boxes GK/RT0065 Train Operated Points 8 R A I L T R A C K

Warning Signs & Labels Fitted to Electrical Equipment on Rail Mounted Vehicles

Warning Signs & Labels Fitted to Electrical Equipment on Rail Mounted Vehicles Railway Group Standard Date August 1996 Warning Signs & Labels Fitted to Electrical Equipment on Rail Mounted Vehicles Synopsis This Standard details the requirements for Danger: electricity triangular

More information

Hot Axle Box Detectors - Siting

Hot Axle Box Detectors - Siting GO/RT3207 Hot Axle Box Detectors - Siting Submitted by... R Merryweather Nominated Responsible Manager Approved by... M Harwood Chairman, Operations Standards Subject Committee Authorised by Synopsis To

More information

GK/GN0612. Guidance on Signalling Lockout Systems to Protect Railway. Undertaking Personnel. Railway Group Guidance for GK/RT0212.

GK/GN0612. Guidance on Signalling Lockout Systems to Protect Railway. Undertaking Personnel. Railway Group Guidance for GK/RT0212. GN Published by Rail Safety and Standards Board Evergreen House 160 Euston Road London NW1 2DX Copyright 2007 Rail Safety and Standards Board Limited GK/GN0612 Issue One: August 2007 Railway Group Guidance

More information

Facing Point Lock and Detection Testing

Facing Point Lock and Detection Testing Discipline: Engineering (Signalling) Category: Procedure Facing Point Lock and Detection Testing ESM-06-01 Applicability ARTC Network Wide CRIA (NSW CRN) Primary Source NSW Standards SMP 28, SMP 29, SMP

More information

CIRCUIT BREAKER FAIL PROTECTION

CIRCUIT BREAKER FAIL PROTECTION CIRCUIT BREAKER FAIL PROTECTION This document is for Relevant Electrical Standards document only. Disclaimer NGG and NGET or their agents, servants or contractors do not accept any liability for any losses

More information

Railway Signal and Traffic Control Systems Standards

Railway Signal and Traffic Control Systems Standards Railway Signal and Traffic Control Systems Standards June 4, 2007 TM Railway Signal and Traffic Control Systems Standards Effective: June 4, 2007 CONTENTS 1. SCOPE 2. DEFINITIONS 3. RAILWAY SIGNALING DESIGN

More information

GI/GN7520. Guidance on Lighting of Railway Premises. Railway Group Guidance Note

GI/GN7520. Guidance on Lighting of Railway Premises. Railway Group Guidance Note GN Published by Rail Safety and Standards Board Evergreen House 160 Euston Road London NW1 2DX Copyright 2007 Rail Safety and Standards Board Limited GI/GN7520 Issue 1 December 2007 Railway Group Guidance

More information

PART 3-O REQUIREMENTS FOR SPRINKLER SYSTEMS MAINTENANCE AND SUPERVISION. 3-O Introduction O.1 Scope of Maintenance and Supervision...

PART 3-O REQUIREMENTS FOR SPRINKLER SYSTEMS MAINTENANCE AND SUPERVISION. 3-O Introduction O.1 Scope of Maintenance and Supervision... CONTENTS Schedule of amendments for this part of the scheme document Page 1 of 14 3-O Introduction...3 3-O.1 Scope of Maintenance and Supervision...3 3-O.2 Certification conditions...5 3-O.3 LPS 1233 Service

More information

Policy for safe working on Fire Alarm Systems at Loughborough University and Loughborough University in London

Policy for safe working on Fire Alarm Systems at Loughborough University and Loughborough University in London Policy for safe working on Fire Alarm Systems at Loughborough University and Loughborough University in London Scope of document General This document sets out the procedure for the management and control

More information

Building Standards Division. Whisky Maturation Warehouses Storage Buildings (Class 1) Automatic Fire Suppression Systems

Building Standards Division. Whisky Maturation Warehouses Storage Buildings (Class 1) Automatic Fire Suppression Systems Building Standards Division Whisky Maturation Warehouses Storage Buildings (Class 1) Automatic Fire Suppression Systems Crown Copyright 2015 Produced by the Buildings Standards Division February 2015 Version

More information

Croxley Rail Link Watford Vicarage Road Station Reference Number :

Croxley Rail Link Watford Vicarage Road Station Reference Number : PART A Report to: Development Management Section Head To Committee: Date of Committee: 3 rd April 2014 Site address: Croxley Rail Link Watford Vicarage Road Station Reference Number : 14/00101/DISCON Description

More information

Australian/New Zealand Standard

Australian/New Zealand Standard AS/NZS 3500.4:2003 (Incorporating Amendment Nos 1 and 2) AS/NZS 3500.4:2003 Australian/New Zealand Standard Plumbing and drainage Part 4: Heated water services AS/NZS 3500.4:2003 This Joint Australian/New

More information

Substation Signage. Document Number: 1-11-FR-12

Substation Signage. Document Number: 1-11-FR-12 Substation Signage Document Number: 1-11-FR-12 VERSION 1.0 June 2018 This functional requirements document is in line with the organisation's 1-11-ACS-12 Substation Signage Asset Class Strategy Intellectual

More information

EIA STANDARD TP-38B EIA B. Cable Pull-Out Test Procedure for Electrical Connectors. EIA/ECA B (Revision of EIA A)

EIA STANDARD TP-38B EIA B. Cable Pull-Out Test Procedure for Electrical Connectors. EIA/ECA B (Revision of EIA A) EIA STANDARD ANSI/EIA-364-38B-1999(R2006) Approved: April 23, 1999 Reaffirmed: March 31, 2006 TP-38B EIA-364-38B Cable Pull-Out Test Procedure for Electrical Connectors EIA/ECA-364-38B (Revision of EIA-364-38A)

More information

High Speed Rail (London- West Midlands)

High Speed Rail (London- West Midlands) High Speed Rail (London- West Midlands) Draft Environmental Minimum Requirements Annex 3: Draft Heritage Memorandum November 2013 ESA 4.4 High Speed Rail (London- West Midlands) Draft Environmental Minimum

More information

DESIGN AND MANAGEMENT OBJECTIVES PART 7 HA 92/01 SCHEME DEVELOPMENT, IMPLEMENTATION & MANAGEMENT SUMMARY

DESIGN AND MANAGEMENT OBJECTIVES PART 7 HA 92/01 SCHEME DEVELOPMENT, IMPLEMENTATION & MANAGEMENT SUMMARY DESIGN MANUAL FOR ROADS AND BRIDGES VOLUME 10 SECTION 0 ENVIRONMENTAL DESIGN AND MANAGEMENT ENVIRONMENTAL OBJECTIVES PART 7 HA 92/01 SCHEME DEVELOPMENT, IMPLEMENTATION & MANAGEMENT SUMMARY This Advice

More information

Australian/New Zealand Standard

Australian/New Zealand Standard AS/NZS 3760:2003 (Incorporating Amendment No. 1) AS/NZS 3760:2003 Australian/New Zealand Standard In-service safety inspection and testing of electrical equipment AS/NZS 3760:2003 This Joint Australian/New

More information

Croxley Rail Link - Cassiobridge Station, Ascot Road Reference Number :

Croxley Rail Link - Cassiobridge Station, Ascot Road Reference Number : PART A Report of: Development Management Section Head Date of Committee 3 rd April 2014 Site address: Croxley Rail Link - Cassiobridge Station, Ascot Road Reference Number : 14/00097/DISCON Description

More information

AS/NZS :2009. Performance of household electrical appliances Refrigerating appliances AS/NZS :2009

AS/NZS :2009. Performance of household electrical appliances Refrigerating appliances AS/NZS :2009 AS/NZS 4474.2:2009 (Incorporating Amendment Nos 1 and 2) Australian/New Zealand Standard Performance of household electrical appliances Refrigerating appliances Part 2: Energy labelling and minimum energy

More information

Australian Standard. Safeguarding of machinery

Australian Standard. Safeguarding of machinery AS 4024.2 1998 Australian Standard Safeguarding of machinery Part 2: Installation and commissioning requirements for electro-sensitive systems Optoelectronic devices This Australian Standard was prepared

More information

Australian/New Zealand Standard

Australian/New Zealand Standard AS/NZS 2293.2:1995 Australian/New Zealand Standard Emergency evacuation lighting for buildings AS/NZS 2293.2:1995 This Joint Australian/New Zealand Standard was prepared by Joint Technical Committee LG/7,

More information

AS/NZS :2015. Plumbing and drainage AS/NZS :2015. Part 4: Heated water services. Australian/New Zealand Standard

AS/NZS :2015. Plumbing and drainage AS/NZS :2015. Part 4: Heated water services. Australian/New Zealand Standard AS/NZS 3500.4:2015 Incorporating Amendment No. 1 Australian/New Zealand Standard Plumbing and drainage Part 4: Heated water services Superseding AS/NZS 3500.4:2003 AS/NZS 3500.4:2015 AS/NZS 3500.4:2015

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60601-2-44 Edition 2.1 2002-11 Edition 2:2001 consolidée par l'amendement 1:2002 Edition 2:2001 consolidated with amendment 1:2002 Medical electrical equipment Part 2-44: Particular

More information

Fire Safety Policy 2018/19

Fire Safety Policy 2018/19 Fire Safety Policy 2018/19 Reviewed: March 2016 Next Review: March 2019 1. Policy Statement The School is committed to ensuring, so far as is reasonably practicable, the health, safety and welfare of all

More information

CHAPTER Committee Substitute for Committee Substitute for Committee Substitute for House Bill No. 973

CHAPTER Committee Substitute for Committee Substitute for Committee Substitute for House Bill No. 973 CHAPTER 2013-203 Committee Substitute for Committee Substitute for Committee Substitute for House Bill No. 973 An act relating to low-voltage systems; amending s. 489.503, F.S.; revising an exemption from

More information

South Australian Regulatory Requirements

South Australian Regulatory Requirements South Australian Regulatory Requirements Australian Legislative Framework Act Act of Parliament Establishes the Law Primary legislation Regulation Subordinate legislation authorised by a specific Act Therefore

More information

For the Design, Installation, Commissioning & Maintenance of Fire Detection and Fire Alarm Systems

For the Design, Installation, Commissioning & Maintenance of Fire Detection and Fire Alarm Systems BAFE Scheme: SP203-1 Version 5: May 2011 Fire Protection Industry Scheme, Reference SP203 Part 1 For the Design, Installation, Commissioning & Maintenance of Fire Detection and Fire Alarm Systems British

More information

AREMA C&S Manual 2018 (Includes 2018 Revisions) Volume 4 Index. Part C Type & Subject Pages Status

AREMA C&S Manual 2018 (Includes 2018 Revisions) Volume 4 Index. Part C Type & Subject Pages Status SECTION 16 - VITAL CIRCUIT AND SOFTWARE DESIGN 16.1 Recommended Nomenclature 16.1.1 37-3 Recommended Circuit Nomenclature 17 Revised 2012 16.2 Recommended Symbols 16.2.1 37-3 Recommended Graphical Symbols

More information

MERIT SERIES Downflow

MERIT SERIES Downflow PRODUCT SPECIFICATIONS GAS FURNACES ML80DF MERIT SERIES Downflow Bulletin No. 20643 February 208 Supersedes November 207 AFUE - 80% Input - 44,000 to 0,000 Btuh Nominal Add-on Cooling -.5 to 5 Tons MODEL

More information

Rancho Cucamonga Fire Protection District Prevention Bureau Standard

Rancho Cucamonga Fire Protection District Prevention Bureau Standard Rancho Cucamonga Fire Protection District Prevention Bureau Standard Title: Fire Alarm and Monitoring Systems Standard # 9-3 Effective: May 2002 Number of Pages: 7 Updated: December 2016 for consistency

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60384-22-1 First edition 2004-06 Fixed capacitors for use in electronic equipment Part 22-1: Blank detail specification: Fixed surface mount multilayer capacitors of ceramic

More information

IMO WORK PROGRAMME. Central control stations and safety centres on passenger ships. Submitted by Argentina and ICCL

IMO WORK PROGRAMME. Central control stations and safety centres on passenger ships. Submitted by Argentina and ICCL INTERNATIONAL MARITIME ORGANIZATION E IMO MARITIME SAFETY COMMITTEE 82nd session Agenda item 21 MSC 82/21/18 29 August 2006 Original: ENGLISH WORK PROGRAMME Central control stations and safety centres

More information

Australian/New Zealand Standard

Australian/New Zealand Standard AS/NZS 1680.5:2012 AS/NZS 1680.5:2012 Australian/New Zealand Standard Interior and workplace lighting Part 5: Outdoor workplace lighting AS/NZS 1680.5:2012 This Joint Australian/New Zealand Standard was

More information

SECTION LOW VOLTAGE POWER PANELBOARDS - SPECTRA

SECTION LOW VOLTAGE POWER PANELBOARDS - SPECTRA PART 1 GENERAL A. The requirements of the Contract, Division 1, and Division 16 apply to work in this Section. 1.01 SECTION INCLUDES A. Low voltage power panelboards 1.02 RELATED SECTIONS 1.03 REFERENCES

More information

Technical Bulletin CE marking: from 1st July 2013

Technical Bulletin CE marking: from 1st July 2013 Technical Bulletin CE marking: from 1st July 2013 New regulation New obligations Same CE mark We are facing the most significant change for a decade in the way that construction products are manufactured

More information

B) Addressing TSI open points: National requirements where there are no TSI requirements. None None None. None None None.

B) Addressing TSI open points: National requirements where there are no TSI requirements. None None None. None None None. National technical rules for infrastructure Related Control Command and Signalling Requirements Note: Relevant TSI is Control, Command and Signalling (Commission Regulation (EU) 2016/919 of 27 May 2016

More information

Australian/New Zealand Standard

Australian/New Zealand Standard AS/NZS 2201.1:2007 AS/NZS 2201.1:2007 Australian/New Zealand Standard Intruder alarm systems Part 1: Client s premises Design, installation, commissioning and maintenance AS/NZS 2201.1:2007 This Joint

More information

COMMISSION DELEGATED REGULATION (EU)

COMMISSION DELEGATED REGULATION (EU) 28.5.2014 L 159/41 REGULATIONS COMMISSION DELEGATED REGULATION (EU) No 574/2014 of 21 February 2014 amending Annex III to Regulation (EU) No 305/2011 of the European Parliament and of the Council on the

More information

INSTALLATION & USER INSTRUCTIONS

INSTALLATION & USER INSTRUCTIONS INSTALLATION & USER INSTRUCTIONS INSET LED ELECTRIC FIRE MODELS COVERED BY THESE INSTRUCTIONS Focal Point Fires Christchurch, Dorset BH23 2BT Tel: 01202 588 632 Fax: 01202 499326 www.focalpointfires.co.uk

More information

Australian Standard. Components for the protection of openings in fire-resistant walls. Part 1: Fire-resistant doorsets AS AS 1905.

Australian Standard. Components for the protection of openings in fire-resistant walls. Part 1: Fire-resistant doorsets AS AS 1905. AS 1905.1 2005 AS 1905.1 2005 Australian Standard Components for the protection of openings in fire-resistant walls Part 1: Fire-resistant doorsets This Australian Standard was prepared by Committee FP-019,

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60939-2 Second edition 2005-02 Passive filter units for electromagnetic interference suppression Part 2: Sectional specification Passive filter units for which safety tests are

More information

Australian Standard. Fire detection, warning, control and intercom systems System design, installation and commissioning

Australian Standard. Fire detection, warning, control and intercom systems System design, installation and commissioning AS 1670.3 1997 Australian Standard Fire detection, warning, control and intercom systems System design, installation and commissioning Part 3: Monitoring network performance This Australian Standard was

More information

SECTION AUTOMATIC TRANSFER SWITCHES

SECTION AUTOMATIC TRANSFER SWITCHES PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 36 23 SPEC WRITER NOTE: Use this section only for NCA projects. Delete between //--// if not applicable to project. Also, delete any other item or paragraph

More information

INSTALLATION & USER INSTRUCTIONS

INSTALLATION & USER INSTRUCTIONS INSTALLATION & USER INSTRUCTIONS LED ELECTRIC STOVE Christchurch, Dorset BH23 2BT Tel: 01202 588 638 Fax: 01202 499 639 www.ekofires.co.uk e-mail: sales@ekofires.co.uk MODELS COVERED BY THESE INSTRUCTIONS

More information

Electrical Safety Policy and Management System

Electrical Safety Policy and Management System TITLE: PAGE: 1 OF 14 Housing Solutions Limited Electrical Safety Policy and Management System Page 1 of 15 TITLE: PAGE: 2 OF 14 FOREWORD This document details the system for the management of electrical

More information

Proposed Changes to NFPA

Proposed Changes to NFPA 2017 NFPA Conference & Expo Proposed Changes to NFPA 72-2019 Presented by: Manuelita David (SIG-FUN), Jensen Hughes Warren Olsen (SIG-SSS), Fire Safety Consultants, Inc. Merton Bunker (SIG-AAC), EYP Architecture

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60214-1 First edition 2003-02 Tap-changers Part 1: Performance requirements and test methods This English-language version is derived from the original bilingual publication

More information

Testing coated fabrics

Testing coated fabrics BRITISH STANDARD BS 3424-12: 1996 ISO 1419:1995 Incorporating Amendments Nos. 1 and 2 Testing coated fabrics Part 12: Accelerated ageing tests ICS 59.080.40 Committees responsible for this British Standard

More information

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 11/06/2018

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 11/06/2018 SECTION 26 2913 - ENCLOSED CONTROLLERS GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

Legal Requirements. There is no general legal requirement to install sprinklers. in places of work

Legal Requirements. There is no general legal requirement to install sprinklers. in places of work 01 A sprinkler system is a pipework distribution system charged with water, with a network of heatsensitive sprinkler heads supplied via a tank/reservoir or a water main. If the temperature rises above

More information

Substations and high voltage installations exceeding 1 kv a.c.

Substations and high voltage installations exceeding 1 kv a.c. AS 2067:2016 AS 2067:2016 Substations and high voltage installations exceeding 1 kv a.c. This Australian Standard was prepared by Committee EL-043, High Voltage Installations. It was approved on behalf

More information

SOUTH AFRICAN NATIONAL STANDARD

SOUTH AFRICAN NATIONAL STANDARD ISBN 978-0-626-23465-2 SOUTH AFRICAN NATIONAL STANDARD The use and control of fire-fighting equipment Part 2: Fire hose reels and above-ground hydrants Amdt 1 Published by SABS Standards Division 1 Dr

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60601-2-45 Second edition 2001-05 Medical electrical equipment Part 2-45: Particular requirements for the safety of mammographic X-ray equipment and mammographic stereotactic

More information

NOTTINGHAM CITY HOMES

NOTTINGHAM CITY HOMES APPENDIX 1 NOTTINGHAM CITY HOMES FIRE SAFETY POLICY 2013/14 Draft for Board Uncontrolled when printed Page 1 of 14 DOCUMENT CONTROL Identification and Approval Status Document Title: Nottingham City Homes

More information

CE marking of noise barriers and foundations

CE marking of noise barriers and foundations CE marking of noise barriers and foundations Date 2 June 2014 Case officer Charlotte Sejr E - mail cslp@vd.dk Phone +45 7244 2340 Document 14/10726-2 Page 1/13 1 Table of Contents CE MARKING OF NOISE BARRIERS...

More information

Australian/New Zealand Standard

Australian/New Zealand Standard AS/NZS 2293.2:1995 (Incorporating Amendment Nos 1 and 2) AS/NZS 2293.2:1995 Australian/New Zealand Standard Emergency escape lighting and exit signs for buildings AS/NZS 2293.2:1995 This Joint Australian/New

More information

AS/NZS :1995. Emergency escape lighting and exit signs for buildings AS/NZS :1995. Part 2: Inspection and maintenance

AS/NZS :1995. Emergency escape lighting and exit signs for buildings AS/NZS :1995. Part 2: Inspection and maintenance Australia/New Zealand Standard AS/NZS 2293.2:1995 Incorporating Amendment No. 1, 2, and 3 Emergency escape lighting and exit signs for buildings Superseding in part NZS 6742:1971 and AS 2293.2 1987 AS/NZS

More information

OWNER S MANUAL. CoolTower CTF07. (English) (CTF07)

OWNER S MANUAL. CoolTower CTF07. (English) (CTF07) OWNER S MANUAL CoolTower CTF07 (English) (CTF07) SAFETY General Safety Please read these instructions before using the fan and keep for future reference. This appliance is not intended for use by persons

More information

Crossrail. Supplementary Environmental Statement 3. Mapping

Crossrail. Supplementary Environmental Statement 3. Mapping Crossrail Supplementary Environmental Statement 3 Mapping Supplementary Environmental Statement 3 SES3a 3 Contents 1. Introduction 2. Definitions and Sources: 2.1 Revised Scheme and Impacts 2.2 Transport

More information

Australian Standard. Water mist fire protection systems System design, installation and commissioning AS

Australian Standard. Water mist fire protection systems System design, installation and commissioning AS AS 4587 1999 Australian Standard Water mist fire protection systems System design, installation and commissioning This Australian Standard was prepared by Committee FP/12, Aqueous Fire Protection Systems.

More information

Australian Standard. Functional safety Safety instrumented systems for the process industry sector

Australian Standard. Functional safety Safety instrumented systems for the process industry sector AS IEC 61511.2 2004 IEC 61511-2:2003 AS IEC 61511.2 Australian Standard Functional safety Safety instrumented systems for the process industry sector Part 2: Guidelines for the application of AS IEC 61511.1

More information

Road Safety Impact Assessment

Road Safety Impact Assessment Road Safety Impact Assessment October 2016 TRANSPORT INFRASTRUCTURE IRELAND (TII) PUBLICATIONS About TII Transport Infrastructure Ireland (TII) is responsible for managing and improving the country s national

More information

Australian Standard. Fire hydrant installations. Part 1: System design, installation and commissioning AS

Australian Standard. Fire hydrant installations. Part 1: System design, installation and commissioning AS AS 2419.1 1994 (Incorporating Amendment Nos 1 and 2) AS 2419.1 1994 Australian Standard Fire hydrant installations Part 1: System design, installation and commissioning This Australian Standard was prepared

More information

TELECOMMUNICATION EQUIPMENT LOCATED IN THE VICINITY OF PROPOSED DISTRIBUTION HV EARTHS

TELECOMMUNICATION EQUIPMENT LOCATED IN THE VICINITY OF PROPOSED DISTRIBUTION HV EARTHS Network Asset Technical Document TELECOMMUNICATION EQUIPMENT LOCATED IN THE VICINITY OF PROPOSED DISTRIBUTION HV EARTHS Original Issue: August 2006 Prepared by: M. Lamparski This Revision: Rev 1 October

More information

Australian Standard. Security screen doors and security window grilles AS AS 5039

Australian Standard. Security screen doors and security window grilles AS AS 5039 AS 5039 2003 AS 5039 Australian Standard Security screen doors and security window grilles This Australian Standard was prepared by Committee CS-023, Security Screen Doors and Security Window Grilles.

More information

This is a preview - click here to buy the full publication

This is a preview - click here to buy the full publication TECHNICAL REPORT IEC/TR 62730 Edition 1.0 2012-03 HV polymeric insulators for indoor and outdoor use tracking and erosion testing by wheel test and 5 000h test INTERNATIONAL ELECTROTECHNICAL COMMISSION

More information

AS/NZS IEC :2013

AS/NZS IEC :2013 AS/NZS IEC 61347.2.13:2013 (IEC 61347-2-13, Ed.1.0 2006, MOD) Australian/New Zealand Standard Lamp controlgear Part 2.13: Particular requirements for d.c. or a.c. supplied electronic controlgear for LED

More information

Supply and installation of a gas delivery unit for Hydrogen fluoride (HF) and a vertical furnace

Supply and installation of a gas delivery unit for Hydrogen fluoride (HF) and a vertical furnace ANNEX I EUROPEAN COMMISSION JOINT RESEARCH CENTRE Institute for Transuranium Elements (Karlsruhe) Karlsruhe, 18.03.2009 European Commission Institute for Transuranium Elements im Forschungszentrum Karlsruhe

More information

Update all extract references to NFPA documents (including NFPA 72) in Chapter 3 and related annex material to the latest editions.

Update all extract references to NFPA documents (including NFPA 72) in Chapter 3 and related annex material to the latest editions. 11/16/12 TerraView First Revision No. 15-NFPA 720-2012 [ Global Input ] Update all extract references to NFPA documents (including NFPA 72) in Chapter 3 and related annex material to the latest editions.

More information

Changes in NFPA

Changes in NFPA Changes in NFPA 72-2002 2002 Oregon Fire Code Committee November 25, 2003 Michael B. Baker, SET Automatic Fire Alarm Association MikeBaker@afaa.org 2003 Michael B. Baker 1 Table of Contents 1. Administration

More information

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM SECTION 283111 - DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

V4 15JUNE2016 (COPYRIGHT: DEPARTMENT OF INDUSTRY)

V4 15JUNE2016 (COPYRIGHT: DEPARTMENT OF INDUSTRY) V4 15JUNE2016 (COPYRIGHT: DEPARTMENT OF INDUSTRY) ACN 114 572 084 "Driving Sustainability through Teamwork" e: pcthomas@teamcatalyst.com.au m: 0417 405 478 CALCULATING COOL USER GUIDE V4 15JUNE2016 Page

More information

Departure from the Development Plan. Town Council objection to a major application. DETERMINE

Departure from the Development Plan. Town Council objection to a major application. DETERMINE Item No. 9 APPLICATION NUMBER CB/17/01642/OUT LOCATION Land rear of 43 to 91 Silver Birch Avenue South of Alder Green and Aspen Gardens, Aspen Gardens, Stotfold PROPOSAL Outline application for up to 95

More information

Overhead Line Insulators

Overhead Line Insulators Electricity Specification 400I4 Issue 4 January 2016 Overhead Line Insulators Contents 1 Introduction 2 Scope 3 Definitions 4 General Requirements for Approvals and Testing 5 Requirements for Type and

More information

DEEP SEA ELECTRONICS PLC DSE94xx Battery Charger Series Configuration Suite PC Software Manual

DEEP SEA ELECTRONICS PLC DSE94xx Battery Charger Series Configuration Suite PC Software Manual DEEP SEA ELECTRONICS PLC DSE94xx Battery Charger Series Configuration Suite PC Software Manual Document Number: 057-159 Author: Fady Atallah DSE94xx Configuration Suite PC Software Manual ISSUE 15 DSE94xx

More information

Explosives Regulatory Update 2014 CPD CAA SESSION

Explosives Regulatory Update 2014 CPD CAA SESSION 1 Explosives Regulatory Update 2014 CPD CAA SESSION 2 Contact Information Rod Boulay Regional Manager/Sr Inspector of Explosives 1500-605 Robson Street Vancouver, BC V6B 5J3 604-666-0366 Rod.Boulay@nrcan.gc.ca

More information

Date: 23 January Grange and Riverside Ward. Deputy Chief Executive

Date: 23 January Grange and Riverside Ward. Deputy Chief Executive Item No. 8. Classification: Open Date: 23 January 2012 Meeting Name: Bermondsey Community Council Report title: Ward(s) or groups affected: From: Section 106 Release Report for the provisional allocation

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 61810-1 Second edition 2003-08 Electromechanical elementary relays Part 1: General and safety requirements Relais électromécaniques élémentaires Partie 1: Exigences générales

More information

"This is only the scope of work for the project. For more information, interested parties should contact Procurement at

This is only the scope of work for the project. For more information, interested parties should contact Procurement at "This is only the scope of work for the project. For more information, interested parties should contact Procurement at purchasing@stpgov.org to ensure receipt of a full bid package, to be listed as a

More information

BUSINESS PLAN CEN/TC 250 STRUCTURAL EUROCODES EXECUTIVE SUMMARY

BUSINESS PLAN CEN/TC 250 STRUCTURAL EUROCODES EXECUTIVE SUMMARY Page: 1 BUSINESS PLAN CEN/TC 250 STRUCTURAL EUROCODES EXECUTIVE SUMMARY Scope CEN/TC 250 covers the standardization of structural and geotechnical design rules for building and civil engineering works

More information

NPS/003/030 Technical Specification for Transformer and Switchgear Cable Boxes and their associated Bushing Assemblies

NPS/003/030 Technical Specification for Transformer and Switchgear Cable Boxes and their associated Bushing Assemblies Version:- 2.0 Date of Issue:- May 2015 Page 1 of 17 NPS/003/030 Technical Specification for Transformer and Switchgear Cable Boxes and their associated Bushing Assemblies 1. Purpose The purpose of this

More information

SOUTH AFRICAN NATIONAL STANDARD

SOUTH AFRICAN NATIONAL STANDARD ISBN 978-0-626-34241-8 SOUTH AFRICAN NATIONAL STANDARD Industrial body belts Published by SABS Standards Division 1 Dr Lategan Road Groenkloof Private Bag X191 Pretoria 0001 Tel: +27 12 428 7911 Fax: +27

More information

Australian Standard. Gaseous fire extinguishing systems AS (Incorporating Amendment No. 1) AS

Australian Standard. Gaseous fire extinguishing systems AS (Incorporating Amendment No. 1) AS AS 4214 2002 (Incorporating Amendment No. 1) AS 4214 2002 Australian Standard Gaseous fire extinguishing systems This Australian Standard was prepared by Committee FP-011, Gaseous Fire Protection. It was

More information

AS/NZS :2015. Conduit systems for cable management AS/NZS :2015. Part 21: Particular requirements Rigid conduit systems

AS/NZS :2015. Conduit systems for cable management AS/NZS :2015. Part 21: Particular requirements Rigid conduit systems Australian/New Zealand Standard Conduit systems for cable management Part 21: Particular requirements Rigid conduit systems Superseding AS/NZS 2053.2:2001, AS/NZS 2053.6:2001 and AS/NZS 2053.7:2002 This

More information

AGENDA ITEM: 2.3 Industry Standards Co-ordination Committee. Report from Chairman of GEL/9: Cross Functional Electrical European Standards

AGENDA ITEM: 2.3 Industry Standards Co-ordination Committee. Report from Chairman of GEL/9: Cross Functional Electrical European Standards MEETING: DATE: 12 November 2014 SUBJECT: SPONSOR: AUTHOR: AGENDA ITEM: 2.3 Industry Standards Co-ordination Committee Report from Chairman of GEL/9: Cross Functional Electrical European Standards Anson

More information

SECTION P01 LIGHTING AND APPLIANCE PANELBOARDS - A-SERIES

SECTION P01 LIGHTING AND APPLIANCE PANELBOARDS - A-SERIES PART 1 GENERAL A. The requirements of the Contract, Division 1, and Division 16 apply to work in this Section. 1.01 SECTION INCLUDES A. Lighting and appliance panelboards 1.02 RELATED SECTIONS A. 16475,

More information

American National Standard for Electrical Intermediate Metal Conduit

American National Standard for Electrical Intermediate Metal Conduit American National Standard for Electrical Intermediate Metal Conduit Secretariat: National Electrical Manufacturers Association Approved: June 07, 2018 American National Standards Institute, Inc. NOTICE

More information

Australian Standard. Emergency escape lighting and exit signs for buildings. Part 1: System design, installation and operation AS 2293.

Australian Standard. Emergency escape lighting and exit signs for buildings. Part 1: System design, installation and operation AS 2293. AS 2293.1 2005 AS 2293.1 2005 Australian Standard Emergency escape lighting and exit signs for buildings Part 1: System design, installation and operation This Australian Standard was prepared by Committee

More information

volume 11 environmental assessment section 2 environmental impact assessment Part 7 ha 218/08

volume 11 environmental assessment section 2 environmental impact assessment Part 7 ha 218/08 DESIGN MANUAL FOR ROADS AND BRIDGES volume 11 environmental assessment section 2 environmental impact assessment Part 7 ha 218/08 glossary of terms Used in DMRB Volume 11, Sections 1 and 2 SUMMARY This

More information

Loss Prevention Standard

Loss Prevention Standard Loss Prevention Standard LPS 1653: Issue 1.1 This Loss Prevention Standard is the property of BRE Global Ltd. and is made publicly available for information purposes only. Its use for testing, assessment,

More information

Australian/New Zealand Standard

Australian/New Zealand Standard AS/NZS 4645.2:2008 AS/NZS 4645.2:2008 Australian/New Zealand Standard Gas distribution networks Part 2: Steel pipe systems AS/NZS 4645.2:2008 This Joint Australian/New Zealand Standard was prepared by

More information

NZS 7901:2014. Electricity and gas industries Safety management systems for public safety NZS 7901:2014. New Zealand Standard

NZS 7901:2014. Electricity and gas industries Safety management systems for public safety NZS 7901:2014. New Zealand Standard NZS 7901:2014 New Zealand Standard Electricity and gas industries Safety management systems for public safety Superseding NZS 7901:2008 NZS 7901:2014 COMMITTEE REPRESENTATION This standard was prepared

More information

Brookside Walk Children's Play Area, London, NW4

Brookside Walk Children's Play Area, London, NW4 LOCATION: Brookside Walk Children's Play Area, London, NW4 REFERENCE: H/05584/13 Received: 26 November 2013 Accepted: 11 December 2013 WARD(S): Hendon Expiry: 05 February 2014 Final Revisions: APPLICANT:

More information

Summary of changes between PD 6662:2010 and PD 6662:2017 a guide

Summary of changes between PD 6662:2010 and PD 6662:2017 a guide Summary of changes between PD 6662:2010 and PD 6662:2017 a guide October 2017 For other information please contact: British Security Industry Association t: 01905 342 020 e: info@bsia.co.uk www.bsia.co.uk

More information

Australian/New Zealand Standard

Australian/New Zealand Standard AS/NZS 3004:2002 AS/NZS 3004 Australian/New Zealand Standard Electrical installations Marinas and pleasure craft at low-voltage AS/NZS 3004:2002 This Joint Australian/New Zealand Standard was prepared

More information

Project Briefing Document. Section 3 Electrical Services design guide and specifications

Project Briefing Document. Section 3 Electrical Services design guide and specifications ESTATES SUPPORT SERVICE Project Briefing Document Section 3 Electrical Services design guide and specifications Issue 1.1 June 2014 Project Ref. Project Name Project Manager Date issued... Consultant/Contractor...

More information

Australian/New Zealand Standard

Australian/New Zealand Standard AS/NZS 2243.5 Australian/New Zealand Standard Safety in laboratories Part 5: Non-ionizing radiations Electromagnetic, sound and ultrasound This Joint Australian/New Zealand Standard was prepared by Joint

More information

Landscape Act. (Act No. 110 of June 18, 2004)

Landscape Act. (Act No. 110 of June 18, 2004) Landscape Act (Act No. 110 of June 18, 2004) INDEX Chapter I General Provisions (Articles 1 to 7) Chapter II Landscape Plans and Measures Based on Them Section 1 Formulation, etc. of Landscape Plans (Articles

More information

INSTALLATION & USER INSTRUCTIONS

INSTALLATION & USER INSTRUCTIONS INSTALLATION & USER INSTRUCTIONS LED ELECTRIC STOVE Christchurch, Dorset BH23 2BT Tel: 01202 588 638 Fax: 01202 499 639 www.ekofires.co.uk e-mail: sales@ekofires.co.uk MODELS COVERED BY THESE INSTRUCTIONS

More information

Ceiling Sweep Fan Assembly Instructions

Ceiling Sweep Fan Assembly Instructions Ceiling Sweep Fan Assembly Instructions CSF Series Installation Note: This fan must be installed by a licenced electrical contractor Improperly installed ceiling sweep fans can be dangerous and expensive

More information