Model IOR-MA4280/4285 T1 Repeater) Mounting Shelf (4-Inch, 28-Position) User Manual)
|
|
- Bernard Pearson
- 6 years ago
- Views:
Transcription
1 Model IO-MA480/485 epeater) Mounting Shelf (4-Inch, 8-Position) User Manual) 4069-A Model IO-MA480/485 Content Page ODUCION... evision History... rademark Information... elated Publications... PODUC DESCIPION Model IO-MA480 (Wire-Wrapped) Model IO-MA485 (Connectorized Cables)... 5 SPECIFICAIONS SALLAION epeater Mounting Shelf Installation Procedure epeater Mounting Shelf Model MA-480 Wiring Procedure epeater Mounting Shelf Model MA-485 Wiring Procedure... 4 OPEAION CUSOME FOMAION AND ASSISANCE...9 ODUCION his user manual contains descriptions of ADC s epeater 4", 8-Position Mounting Shelves Model IO-MA480 (wire wrap pin connectors) and Model IO-MA485 (with connectorized plugs). Shelf installation procedures, installer wiring connections and an operational section are also included. he epeater 4", 8-Position Mounting Shelves (Models IO-MA480 and IO- MA485) provide a centralized location for mounting and wiring up to 8 epeaters. Network Element connections are made via wire wrap pins (Model IO-MA480) or connectorized plugs (Model IO-MA485) at the back of the shelf. he current repeaters that can be mounted in the epeater Mounting Shelves along with their associated user manuals are listed in able ; the list of discontinued repeaters that can be mounted in the epeater Mounting Shelves are listed in able ev A Page 00, ADC elecommunications, Inc.
2 able. Current epeaters with Associated User Manuals EPEAE Model D Dual Intraoffice epeater Model 544-0B Bridging epeater Model 544-B Dual Bridging Office epeater Model B Short Loop Office epeater Model 544-0B Dual Interbay epeater USE MANUAL ADCP-6-05 ADCP-6-0 ADCP-6-03 ADCP-6-00 ADCP able. Manufacture Discontinued epeaters EPEAE Model and A Dual Intraoffice epeater Model and 544-0A Bridging epeater (single regenerative) Model 544- and 544-A Dual Bridging epeater Model and A Short Loop Office epeater Model and 544-0A Dual Interbay epeater Each mounting shelf occupies two, -inch (5.08 cm) rack spaces in a 3-inch (58.4 cm) relay rack. evision History ISSUE DAE EASON FO CHANGE Issue 6 03/00 Update to current format standard. rademark Information ADC and ADC elecommunications are registered trademarks of ADC elecommunications, Inc. elated Publications Listed below are related manuals and their publication numbers. Copies of these publications can be ordered by contacting the ADC echnical Assistance Center at (in U.S.A. or Canada) or , extension (outside U.S.A. and Canada). itle ADCP Number Application and Engineering Guide System Administrator s Guide 6-50 Page 00, ADC elecommunications, Inc.
3 Admonishments Important safety admonishments are used throughout this manual to warn of possible hazards to persons or equipment. An admonishment identifies a possible hazard and then explains what may happen if the hazard is not avoided. he admonishments in the form of Dangers, Warnings, and Cautions must be followed at all times. hese warnings are flagged by use of the triangular alert icon (seen below), and are listed in descending order of severity of injury or damage and likelihood of occurrence. Danger: Danger is used to indicate the presence of a hazard that will cause severe personal injury, death, or substantial property damage if the hazard is not avoided. Warning: Warning is used to indicate the presence of a hazard that can cause severe personal injury, death, or substantial property damage if the hazard is not avoided. Caution: Caution is used to indicate the presence of a hazard that will or can cause minor personal injury or property damage if the hazard is not avoided. PODUC DESCIPION he epeater 4", 8-Position Mounting Shelves (Models IO-MA480 and MA485) shown in Figure, provide 8 mounting slots for ADC s epeater plug-in modules. he mounting slots support and guide the plug-in modules into -pin card edge connectors mounted on the inside rear of the mounting shelf s frame. Each epeater Shelf consists of a steel chassis with top and bottom vent slots to provide heat dispersion and adjustable mounting brackets allowing the shelf to be installed flush or extend two, four, or five inches (5.08, 0.6, or.70 cm) beyond the front of the relay rack (58.4 CM) (7.6 CM).5. (5.7 CM).3. (56.67 CM) 4000-A Figure. epeater 4", 8-Position Mounting Shelf Model IO-MA480 and IO-MA485 (Front View) he back of the epeater Mounting Shelf provides twenty-eight -pin terminal strips for connecting transmit and receive lines, two independent battery supplies, alarm connections and chassis (frame) ground. he pin assignments for the -pin terminal strip are shown in Figure. he alpha pin designations refer to the right-hand column of terminals and the numeric designations refer to the left-hand terminals, as viewed from the back. A removable plastic shield mounts over the rear of the mounting shelf to prevent accidental contact with the wire wrap terminals. Page 3 00, ADC elecommunications, Inc.
4 PU EGEN. A OUPU EGEN. A NGND F E D C B A ALAM CHASSIS GND SHIELD (OPIONAL) PU EGEN. B OUPU EGEN. B 653-C Figure. Pin Assignments for the -Pin erminal Strip Each epeater Mounting Shelf may be equipped with an alarm relay board located on the backplane 8th position. he alarm relay furnishes two sets of normally open (NO) wire wrap dry contact terminals. A mounting position alarm condition (plug-in module fuse failure) causes the alarm relay to operate and the (NO) contacts to close. After the alarm condition is cleared, the relay releases and the contacts return to their (NO) position.. Model IO-MA480 (Wire-Wrapped) he rear view of the epeater Mounting Shelf with an exploded view of the alarm relay board is shown in Figure 3. All external connections to the mounting shelf; i.e., transmit and receive lines, dual power ( and NGND), and alarm leads are made via twentyeight -pin wire wrap terminal strips located at the back of the shelf. A chassis ground terminal is provided for terminating office frame ground CHAS GND 3998-B 8 7 O P 6, EMAL SIP 6. "EVEN" B BAEY SUPPLY CHASSIS GOUND 3 6 F 6 ALAM # (NO) ALAM ELAY BOAD ALAM # (NO) Figure 3. Model IO-MA480 (Wire-Wrap) ear View Page 4 00, ADC elecommunications, Inc.
5 . Model IO-MA485 (Connectorized Cables) he epeater Mounting Shelf (Model IO-MA485), shown in Figure 4, is equipped with four standard 64-pin connectorized plugs designated: PU EGENEAO A (P6), PU EGENEAO B (P7), OUPU EGENEAO A (P8) and OUPU EGENEAO B (P9). transmit and receive line connections are made via the connectorized plugs which are factory wired to their corresponding wire wrap pins. he connectorized plugs are tie wrapped at the rear of the shelf for strain relief. Alarm connections and two power supplies designated Odd A and Even B are terminated at terminal block B located at the rear of the shelf. A chassis ground terminal is provided to connect the office frame ground. P9 (OUPU B) BA (EVEN) BA (ODD) NGND ALM ALM ALM ALM P8 (OUPU A) B BA (EVEN) BA (ODD) NGND ALM ALM ALM ALM CHAS GND B ALAM ELAY BOAD CHASSIS GOUND P7 (PU B) P6 (PU A) 3999-B Figure 4. Model IO-MA485 (Connectorized Plugs), ear View Page 5 00, ADC elecommunications, Inc.
6 SPECIFICAIONS able 3 list the maximum supply current for each epeater model, along with the associated full-shelf maximum current, maximum wattage, and recommended fuse size. able 3. epeater Mounting Shelf Specifications PAAMEE SPECIFICAIONS EMAKS Shelf Dimensions Model IO-MA480 Model IO-MA485 Max. Supply Current epeater Model D 544-0B 544-0B 544-B B B* ecommended Shelf Fuse Size epeater Model D 544-0B 544-0B 544-B B B* Maximum Wattage epeater Model D 544-0B 544-0B 544-B B B* Power equirements Power Supply Environmental Operating emperature Storage elative Humidity Operation Alarm elay Contacts * with 60 ma enabled (H W D) inches ( cm) One epeater 30 ma 50 ma 35 ma 50 ma 38 ma 98 ma* Odd A V Battery.0 A* Full Shelf 40 watts 67 watts 47 watts 67 watts 50 watts 3 watts* 4 to 56 Vdc Full Shelf 40 ma 700 ma 490 ma 700 ma 53 ma.4 A* Even B V Battery.0 A* 0 C to 50 C (+3 F to + F) 40 C to +70 C ( 40 F to +58 F) 0% to 80%.0 Amp maximum Dimensions are the same for both model shelves Full shelf specifications include Odd A V and Even B V battery supplies. Wire power supplies with 0 gauge wire and fuse separately Page 6 00, ADC elecommunications, Inc.
7 3 SALLAION Warning: o prevent electrical shock never install telephone equipment in a wet location or during a lightning storm. When installing or modifying telephone lines, disconnect lines at the network interface before working with uninsulated lines or terminals. his section provides installation and wiring procedures for the epeater Mounting Shelves (Models IO-MA480 and IO-MA485). 3. epeater Mounting Shelf Installation Procedure here are four pre-drilled mounting flange locations available for positioning the shelf in the relay rack. By moving the mounting flanges at the desired pre-drilled location, the mounting shelf can be installed with the front either flush or extended two, four, or five inches (5.08, 0.6, or.70 cm) beyond the front of the relay rack. Install the mounting shelf by inserting it into the designated location in the relay rack. Align the shelf mounting flange holes to the relay rack mounting holes and attach with four inch (.3 cm) machine screws. Note: o minimize heat build-up, mounting shelves should be installed in the relay rack with a two-inch (5. cm) heat baffle between each group of six shelves. efer to -EOP or to other local requirements that may apply, for system-level equipment heat dissipation. 3. epeater Mounting Shelf Model MA-480 Wiring Procedure 3.. Line Connections transmit and receive line connections are made at the twenty-eight -pin wire wrap terminal strips at the back of the shelf. he terminal strip pin designations are shown in Figure 5. Using Figure 5 as reference, connect transmit and receive lines to the designated wire wrap pins at each slot position. Pin C, which may be used to connect to the cable shield when using individual shielded pairs, or the drain wire (shield ground) when using ABAM type cable, is internally connected to the chassis ground. PU EGEN. A OUPU EGEN. A NGND F E D C B A ALAM CHASSIS GND SHIELD (OPIONAL) PU EGEN. B OUPU EGEN. B 653-C Figure 5. ransmit and eceive Line Wiring Diagram (One -Pin erminal Strip Shown for eference) Page 7 00, ADC elecommunications, Inc.
8 3.. Power Connections wo independent power supplies designated Odd A and Even B are required on all installations. Wire wrap pin 6 at each odd numbered slot position and pin 6 on each even numbered slot position are shipped factory wired; pin 3 is factory wired to each slot position. Using 0 gauge wire, connect the 48 Vdc A power supply to wire wrap pin 6 on an odd numbered slot position and the 48 Vdc B power supply to pin 6 on an even numbered slot position, as shown in Figure 6. Connect the battery returns from the A and B power supplies to pin 3 on any slot position. he A and B 48 Vdc supplies are separately fused with the fuse size defined in able 3. Each mounting shelf should be wired and fused in this manner within the bay F 3 3 (ODD) "A" SUPPLY (EVEN) "B" SUPPLY NGND 0080-B Figure 6. Dual Power ( and +V Ground) Installer Connections In some situations it may be desirable to provide a separate 48 Vdc power supply for each of the 8 repeater mounting slots. o accomplish this, remove the two power supplies (odd and even) at the 8 repeater mounting slots and replace them with a separate supply to each mounting slot. he wiring changes are made at the wire wrap terminals on the backplane of the mounting shelf as follows:. Disconnect the white wires ( 48 V) terminated at pin 6 on each terminal strip at the back of the shelf.. Disconnect the black wires (NGND) terminated at pin 3 on each terminal strip at the back of the shelf. 3. Using gauge wire, connect a separate 48 Vdc power supply and battery return to each repeater mounting slot as defined in able 4. Page 8 00, ADC elecommunications, Inc.
9 able 4. Separate Power Supply Connections IEM CONNEC O MG-P IEM CONNEC O MG-P NGND NGND NGND NGND NGND NGND NGND NGND NGND NGND NGND NGND NGND NGND J8-6 J8-3 J7-6 J7-3 J6-6 J6-3 J5-6 J5-3 J4-6 J4-3 J3-6 J3-3 J-6 J-3 J-6 J-3 J0-6 J0-3 J9-6 J9-3 J8-6 J8-3 J7-6 J7-3 J6-6 J6-3 J5-6 J5-3 NGND NGND NGND NGND NGND NGND NGND NGND NGND NGND NGND NGND NGND NGND J4-6 J4-3 J3-6 J3-3 J-6 J-3 J-6 J-3 J0-6 J0-3 J9-6 J9-3 J8-6 J8-3 J7-6 J7-3 J6-6 J6-3 J5-6 J5-3 J4-6 J4-3 J3-6 J3-3 J-6 J-3 J-6 J-3 Page 9 00, ADC elecommunications, Inc.
10 3..3 Alarm Connections An alarm relay board is located on the backplane at the 8th mounting position. he alarm relay furnishes two sets of normally open (NO) wire wrap dry contact terminals. he alarm relay installer wiring connections are shown in Figure V O P 6, EMAL SIP 6. "EVEN" B BAEY SUPPLY 6 ALAM 3 ALAM (NO) O OFFICE AUDIBLE ALAM EQUIPMEN NGND ALAM (NO) O OFFICE VISUAL ALAM EQUIPMEN CHASSIS GOUND ALAM ELAY BOAD 0079-B Figure 7. Alarm elay Installer Wiring Connections he alarm relay board may be bypassed by connecting an ADC fuse and alarm panel to wire wrap pin F as shown in Figure 8. A mounting shelf alarm condition (plug-in module fuse failure) places a 48 V signal on pin F O ADC FUSE AND ALAM PANEL 0078-A Figure 8. ADC Fuse and Alarm Panel Connections Page 0 00, ADC elecommunications, Inc.
11 3.3 epeater Mounting Shelf Model MA-485 Wiring Procedure 3.3. Line Connections transmit and receive line connections are made via four 64-pin plug connectors (located at the back of the shelf) designated: PU EGENEAO A (P6), PU EGENEAO B (P7), OUPU EGENEAO A (P8) and OUPU EGENEAO B (P9). he connectors are factory wired to the twenty-eight -pin wire wrap terminal strips. Pin assignments for P6 (A PU) and P8 (A OUPU) are listed in able 5; P7 (B PU) and P9 (B-OUPU) are listed in able 6. Connect the 64-pin connectorized plugs to the 64- pin receptacles from the DSX equipment cables. able Pin Plug Connector Pin Assignments (A-PU and A-OUPU) SHELF POS SIDE CONN P WIE P6 33 A P A P A P A P A P A P A P A P A P6 0 4 P6 43 A P A P OU CONN P WIE P8 33 P8 34 P P P P P P P8 9 4 P8 0 4 P8 43 P8 44 P (continued) Page 00, ADC elecommunications, Inc.
12 able Pin Plug Connector Pin Assignments (A-PU and A-OUPU), continued SHELF POS SIDE CONN P WIE 4 A P A P A P A P A P A P A P6 0 P6 53 A P A P A P A P A P A P A P OU CONN P WIE P P P P P P8 9 5 P8 0 P8 53 P8 54 P P P P P P able Pin Plug Connector Pin Assignments (B-PU and B-OUPU) SHELF POS SIDE CONN P WIE B P7 33 B P7 34 OU CONN P WIE P9 33 P9 34 (continued) Page 00, ADC elecommunications, Inc.
13 able Pin Plug Connector Pin Assignments (B-PU and B-OUPU), continued SHELF POS SIDE CONN P WIE 3 B P B P B P B P B P B P B P B P7 0 4 B P7 43 B P B P B P B P B P B P B P B P B P7 0 B P7 53 B P7 54 OU CONN P WIE P P P P P P P9 9 4 P9 0 4 P9 43 P9 44 P P P P P P P9 9 5 P9 0 P9 53 P9 54 (continued) Page 3 00, ADC elecommunications, Inc.
14 able Pin Plug Connector Pin Assignments (B-PU and B-OUPU), continued SHELF POS SIDE CONN P WIE 3 B P B P B P B P B P B P OU CONN P WIE P P P P P P Power Connections wo independent 48 Vdc power supplies designated Odd A and Even B are required for all installations. A rear mounted terminal block (B) provides the installer connections for the 48 Vdc power supplies. he terminal position designated Odd A is factory wired to multiple wire wrap pin 6 on the odd numbered slot positions of the shelf; the Even B terminal position is factory wired to multiple wire wrap pin 6 on the even numbered slot positions. he terminal position designated NGND is factory wired to multiple wire wrap pin 3. Each power supply is separately fused with the corresponding fuse size defined in able Alarm Connections An alarm relay board is located on the backplane at the 8th mounting position. Installer wiring connections for alarm and alarm are made at the ALM and ALM positions on terminal strip B which is factory wired to the alarm relay board as shown in Figure 9. he alarm relay furnishes two sets of normally open (NO) dry contact terminals. A mounting position alarm condition (plug-in module fuse failure) causes the alarm relay to operate and the (NO) contacts to close. After the alarm condition is cleared, the relay releases and the contacts return to their (NO) position. Page 4 00, ADC elecommunications, Inc.
15 BA (EVEN) BA (ODD) NGND ALM ALM ALM ALM CHAS GND B ALAM (NO) FACOY WIED O B (ALAM ) 8 BA (EVEN) BA (ODD) NGND ALM ALM ALM ALM 6 F 6 ALAM NGND B ALAM (NO) FACOY WIED O B (ALAM ) ALAM ELAY BOAD Figure 9. IO-MA485 Alarm elay Connections he alarm relay board may be bypassed by connecting an ADC fuse and alarm panel to the factory wired ALAM terminal position on B which is multipled to pin F at each slot position. A mounting shelf alarm condition (plug-in module fuse failure) places 48 Vdc signal on pin F. Page 5 00, ADC elecommunications, Inc.
16 4 OPEAION A typical bidirectional Dual Intraoffice epeater arrangement between an Exchange Carrier DSX- (location A) and an Interexchange Carrier DSX- (location B) is shown in Figure 0. EXCHANGE CAIE LOCAION A DSX- MOUNG SHELF POSIIONS -8 I/O EPEAE EEXCHANGE CAIE LOCAION B DSX- 5 4 O OB OU OU B EGEN. A E OU OU O EMAL A D X-CONN EGEN. B X-CONN 655-A Figure 0. ypical Bi-directional Dual Intraoffice epeater Arrangement Between wo Carriers Figure shows a typical unidirectional Dual Intraoffice epeater arrangement between an Exchange Carrier DSX- (location A) and an Interexchange Carrier DSX- (location B). EXCHANGE CAIE LOCAION A MOUNG SHELF DSX- POSIIONS -8 EEXCHANGE CAIE LOCAION B MOUNG SHELF POSIIONS -8 DSX- I/O EPEAE I/O EPEAE O OB OU OU 5 4 EGEN. A 5 4 EGEN. A OU OU O EMAL X-CONN X-CONN OU OU B A E D EGEN. B E D B A EGEN. B OU OU O EMAL X-CONN X-CONN 656-A Figure. ypical Unidirectional Dual Intraoffice epeater Arrangement Between wo Carriers Page 6 00, ADC elecommunications, Inc.
17 Service transfers at DSX- locations may require the cross-connects between jacks to exceed the 85 foot limit. Figure shows the typical arrangement of a Dual Intraoffice or Dual Interbay epeater when the DSX- Interbay cross-connects exceed 85 feet. DSX- DSX- O COSS-AISLE EMAL OVE 85 FEE DSX- O COSS-AISLE EMAL DSX- I/O EPEAE 5 4 O OB OU B EGEN. A E OU O EMAL A D EGEN. B MOUNG SHELF POSIION A Figure. ypical Interbay Dual epeater Arrangement A typical Short Loop epeater arrangement is shown in Figure 3. MOUNG SHELF POSIIONS -8 DSX- SHO LOOP EPEAE 5 4 O SPAN LE B EGEN. A E OU OU O EMAL A D EGEN. B X-CONN 658-A Figure 3. ypical Short Loop epeater Arrangement Page 7 00, ADC elecommunications, Inc.
18 A typical Bridging Office epeater arrangement for an in-service patch to a stand-by network element is shown in Figure 4. NGND L L NGND COSS-CONNEC JUMPES NEWOK ELEMEN A OU OU EM PLUG 3 OU OU NEWOK ELEMEN B a PACH CODS EM PLUG L NGND OU OU BIDGG EPEAES b OU OU NEWOK ELEMEN SANDBY d c 8794-C Figure 4. A ypical Bridging Office epeater Arrangement for an In-Service Patch to a Stand-by Network Element Page 8 00, ADC elecommunications, Inc.
19 5 CUSOME FOMAION AND ASSISANCE For customers wanting information on ADC products or help in using them, ADC offers the services listed below. o obtain any of these services by telephone, first dial the central ADC telephone number, then dial the extension provided below. he central number for calls originating in the U.S.A. or Canada is For calls originating outside the U.S.A. or Canada, dial country code then dial Sales Assistance Extension Systems Integration Extension BCG echnical Assistance Center Extension bcg_tac@adc.com Product eturn Department Extension repair&return@adc.com Quotation Proposals Ordering and Delivery General Product Information Complete Solutions (from Concept to Installation) Network Design and Integration esting System urn-up and esting Network Monitoring (Upstream or Downstream) Power Monitoring and emote Surveillance Service/Maintenance Agreements Systems Operation echnical Information System/Network Configuration Product Specification and Application raining (Product-Specific) Installation and Operation Assistance roubleshooting and epair ADC eturn Authorization number and instructions must be obtained before returning products. Product information may also be obtained using the ADC web site at or by writing ADC elecommunications, Inc., P.O. Box 0, Minneapolis, MN , U.S.A. Contents herein are current as of the date of publication. ADC reserves the right to change the contents without prior notice. In no event shall ADC be liable for any damages resulting from loss of data, loss of use, or loss of profits and ADC further disclaims any and all liability for indirect, incidental, special, consequential or other similar damages. his disclaimer of liability applies to all products, publications and services during and after the warranty period. his publication may be verified at any time by contacting ADC s echnical Assistance Center at , extension (in U.S.A. or Canada) or (outside U.S.A. and Canada), or by to bcg_tac@adc.com. 00, ADC elecommunications, Inc. All ights eserved Printed in U.S.A. Page 9
Model T B Intraoffice T1 Repeater User Manual
Model 544-01B Intraoffice Repeater User Manual Model 544-01B 15404-A Content Page INTRODUCTION... 1 Revision History... 2 Trademark Information... 2 1 PRODUCT DESCRIPTION... 2 2 SPECIFICATIONS... 5 3 INSTALLATION...
More informationDS3/STS-1 Protected Repeater System User Manual
13959-A ADCP-61-061 Issue 3 August 2000 DS3/STS-1 Protected Repeater System User Manual 8289-A 8288-A 23-Inch, 16-Slot Chassis 19-Inch, 12-Slot Chassis (shown with 23-inch extension brackets) 8287-A Portable
More informationNG4access ODF Platform Standard Chassis Installation Manual
NG4access ODF Platform Standard Chassis Installation Manual TECP-90-703 Issue 1 8/2012 24939-A Content Page INTRODUCTION...1 1 PRODUCT DESCRIPTION...2 2 MAIN COMPONENTS...3 3 GROUNDING AND BONDING THE
More informationRibbon Breakout Kit Installation Instructions
Ribbon Breakout Kit Installation Instructions LOOSE BUFFER TUBE RIBBON KIT BLK-RLBT- (SEE PAGE 3) CENTRAL OVAL TUBE RIBBON KIT BLK-RCT- (SEE PAGE 12) RIBBON CENTRAL TUBE KIT BLK-RCT- (SEE PAGE 20) 19645-A
More informationInstalling the Cisco ONS FAP-4 Fuse Alarm Panel
Installing the Cisco ONS 15454-FAP-4 Fuse Alarm Panel Product Number: 15454-FAP-4= This document explains how to install, test, operate, and maintain the Cisco ONS 15454-FAP-4 fuse alarm panel. This document
More informationFUSE PANEL Technical Practice N N/L9 10/10 GMT NEBS Level 3 Certified
0226-03K August 13, 2008 FUSE PANEL Technical Practice N250120-N/L9 10/10 GMT NEBS Level 3 Certified FEATURES 2 isolated groups (busses) of 10 GMT fuses in each (15Amps/GMT position). Polarity insensitive
More informationGDC 087R Issue 2 - May Installation and Operation UAS Shelf/Enclosure. General DataComm
GDC 087R701-000-02 Issue 2 - May 1998 Installation and Operation UAS 7000 Shelf/Enclosure General DataComm Manual Revision History Shown below is a chronological listing of revisions to this manual. The
More informationTotal Access 1500 SCU Installation and Maintenance
CONENS 1. GENERAL... 1 2. INSALLAION... 2 3. OPERAION... 3 4. MAINENANCE... 9 5. PRODUC SPECIFICAIONS... 9 6. WARRANY AND CUSOMER SERVICE. 10 FIGURES Figure 1. otal Access 1500 SCU... 1 Figure 2. System
More informationCOMSPHERE 48 Vdc CENTRAL OFFICE POWER UNIT
COMSPHERE 48 Vdc CENTRAL OFFICE POWER UNIT INSTALLATION GUIDE Document No. 3000-A2-GB41-50 October 2002 COMSPHERE 48 Vdc Central Office Power Unit COMSPHERE 48 Vdc Central Office Power Unit Installation
More informationEnvironmental Monitoring SmartSlot Card
Environmental Monitoring SmartSlot Card AP9612TH Installation and Quick Start Manual Contents Introduction............................. 1 Overview 1 Product inventory 1 Safety notice 2 Your inspection
More informationNoran Tel. FUSE PANEL Technical Practice N NCY 2/2 KLM and 4/4 GMT NEBS Level 3 Certified
0232-03J December 13, 2006 FUSE PANEL Technical Practice N215112-NCY 2/2 KLM and 4/4 GMT NEBS Level 3 Certified FEATURES 2 isolated groups (busses) of 2 KLM and 4 GMT fuses in each (30Amps/KLM, 15Amps/GMT).
More informationSafety, Installation, and Operation Manual
Automatic Steam Humidifier Control Safety, Installation, and Operation Manual READ COMPLETE INSTALLATION INSTRUCTIONS BEFORE STARTING. WARNING This product must be installed by a qualified heating and
More informationFUSE PANEL. Technical Practice N N/L33 10/10 GMT Front Access NEBS Level 3 Certified
0220-03J Oct 9, 2006 Noran Tel FUSE PANEL Technical Practice N25020-N/L33 0/0 GMT Front Access NEBS Level 3 Certified FEATURES 2 isolated groups (busses) of 0 GMT fuses in each (5Amps/GMT position). Polarity
More informationFUSE PANEL. Technical Practice N N/0803 5/5 GMT Front Access NEBS Level 3 Certified
0803-03B April 17, 2008 Noran Tel PANEL Technical Practice N250110-N/0803 5/5 GMT Front Access NEBS Level 3 Certified FEATURES 2 isolated groups (busses) of 5 GMT fuses in each (15Amps/GMT position). Polarity
More informationSoneplex FIBER LOOP CONVERTER REFERENCE GUIDE
Soneplex FIBER LOOP CONVERTER REFERENCE GUIDE Product Catalog: DS3-B2LDFC, DS3-B2LDSC, QFC-D3LDSC, QFC-D3LDFC, E1Q-B2LDFC CLEI: SNCUAGJ3, SNCUAGK3, T1OPM5D4, T1OPM5F4 ADCP-RG-61-124-09 Revision History
More informationMODEL 8143 SIGNAL SELECTOR INSTALLATION AND OPERATION MANUAL
MODEL 8143 SIGNAL SELECTOR INSTALLATION AND OPERATION MANUAL 95 Methodist Hill Drive Rochester, NY 14623 Phone: US +1.585.321.5800 Fax: US +1.585.321.5219 www.spectracomcorp.com Part Number 8143-5000-0050
More informationFigure 1. Figure 2. See notes 1 and 2 below.
273 Branchport Avenue Long Branch, N.J. 07740 (800) 631-2148 Thank you for using our products. www.wheelockinc. com INSTALLATION INSTRUCTIONS HORN SPEAKER WITH AMPLIFIER Use this product according to this
More informationModel Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:
Model 2102 Gas Alarm Panel APPLICABILITY & EFFECTIVITY This manual provides instructions for the following Sierra Monitor products: Model Description 2102-00 Alarm Panel 2 Channel 2102-01 Alarm Panel 2
More informationSTATUS ALARM ALARM HISTORY POWER HISTORY RESET
Instruction Manual Model 1582-70L2 RF Switch June 2011, Rev. D CH1 AUTO CH2 SWITCH 1 2 1 2 STATUS 1 2 MODEL 1582 SWITCH CROSS TECHNOLOGIES INC. CH1 ONLINE MANUAL SELECT CH2 SWITCH MANUAL REMOTE ONLINE
More informationQ7100A,C,D Thermostat Subbases
Q700A,C, hermostat Subbases INSALLAION INSRUCIONS APPLICAION he Q700 hermostat Subbases provide electronic control of commercial Vac single or multistage heat pump or conventional heating and cooling systems.
More informationWARNING FOR SERVICE TECHNICIAN S USE ONLY
ech Sheet Do not discard ANING Electrical Shock Hazard Disconnect power before servicing. eplace all parts and panels before operating. Failure to do so can result in death or electrical shock. Software
More informationEnvironmental Monitoring Card
Environmental Monitoring ard AP9612TH Installation and Quick-Start Manual ontents Introduction............................. 1 Overview............................. 1 Product inventory......................
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS The SensorNet I/O Module provides attachment for up to 32 alarms and up to 16 switched devices. An RS-232 or RS-422 communications port is also provided for receiving serial alarms.
More informationSierra Series 900 Single & Dual Channel System. Instruction Manual
Series 240/24 Instruction Manual Table of Contents Sierra Series 900 Single & Dual Channel System Instruction Manual Part Number IM-90-07/05 Revision D. 5 Harris Court, Building L Monterey, CA 93940 (83)
More informationIntroduction... 1 System Overview... 1 System Diagram... 2
TABLE OF CONTENTS Introduction... 1 System Overview... 1 System Diagram... 2 Installation... 3 Console Mounting... 3 Monitor And Power Connections... 3 ASM II Console Main Harness... 4 Module Mounting...
More informationTrueCom. Building Communications Systems 5115-Series , Area of Rescue Communications System. Description
TrueCom Building Communications Systems 5115-Series 5115-9001, -9002 Area of Rescue Communications System Description The Simplex 5115-9001 and -9002 Area of Rescue Communications System provides buildings
More informationQ7300L Series 2000 Commercial Thermostat Subbases
Q700L Series 2000 Commercial hermostat Subbases INSALLAION INSRUCIONS APPLICAION he Q700L hermostat Subbase is used with the 700D,F hermostat to provide electronic control of commercial 24 Vac single zone
More informationProtocol Station Remote Alarm
ADI 5135-C Certified ISO 9001 Protocol Station Remote Alarm 529 5135-01-120 529 5135-01-220 INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Controls Corporation
More informationInstallation Instructions
Fixture Mount Night Light Controller SPECIFICATIONS Power.....................................120VAC, 60Hz Relay Type..................................Form C, N.O. Load Requirements @120VAC......................................500W..........................
More informationBeacon 800 Gas Monitor Operator s Manual
Beacon 800 Gas Monitor Operator s Manual Part Number: 71-0037RK Revision: F Released: 4/18/17 www.rkiinstruments.com Product Warranty RKI Instruments, Inc. warrants gas alarm equipment sold by us to be
More informationInstallation and Operating Instructions
The Leader of RF and Sonic Level For Assistance Call 1-800-527-6297 Outside North America 1-215-674-1234 Installation and Operating Instructions Series 504-1200 Ultrasonic VeriGAP Switch using 404-1200
More informationErie WA300. Application. Features. Two Zone Hydro-Air Relay General Instructions
Building Systems - Americas Invensys Energy Solutions 354 lifford Avenue (Zip 6) P.O. Box 940 Loves Park, IL 63-940 United States of America www.ies.invensys.com Erie A300 wo Hydro-Air elay eneral Instructions
More information12.0 cu.ft., 2 way, 4-door, R.V. refrigerator with ice maker.
Installation Manual For 1200ACXX models: For 120XAC-IMXX models: 12.0 cu.ft., 2-way, 4-door, R.V. refrigerator. 12.0 cu.ft., 2 way, 4-door, R.V. refrigerator with ice maker. The letter X, in the model
More informationSA SIREN AMPLIFIER
Carson Manufacturing Co., Inc. 5451 North Rural Street Indianapolis, IN 46220 Phone: (888) 577-6877 Fax: (317) 254-2667 www.carsonsirens.com SA-365-10 SIREN AMPLIFIER Y E L P STANDBY SA-365 W AI L OUTPUT
More informationSingle Station Remote Alarm
ADI 5106C Certified ISO 9001 Single Station Remote Alarm 529 5106-01-120 529 5106-01-220 INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Controls Corporation
More informationLORAIN CIP 4890/48120 DC Power System
DC Power for Business-Critical Continuity Key Features Compact flexibility provides rectifiers, distribution, and controller in one shelf Constant power delivers more current at lower voltages to meet
More informationOperating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm
Operating & Maintenance Manual Alert-4 Ethernet LCD Master Alarm w w w. a m i c o. c o m Contents User Responsibility 4 Introduction 4 Features 5 Description of the Alarm 5 Shipment Details 5 The Alarm
More informationPM100/PM100E PLANTER MONITOR. Operator s Manual
PM100/PM100E PLANTER MONITOR Operator s Manual TABLE OF CONTENTS Safety Notices... 1 Introduction... 3 System Overview... 3 Installation... 5 Console Mounting... 5 Monitor and Power Connections... 5 Console
More informationSTATUS ALARM ALARM HISTORY POWER HISTORY RESET
Instruction Manual Model 1582-152 RF Protection Switch November 2009, Rev B. CH1 AUTO CH2 SWITCH 1 2 1 2 STATUS 1 2 MODEL 1582 SWITCH CROSS TECHNOLOGIES INC. CH1 ONLINE MANUAL SELECT CH2 SWITCH MANUAL
More informationVESDA. Accessories Guide. May 2011 Document: 10258_06 Part Number: 30012
VESDA Accessories Guide May 2011 Document: 10258_06 Part Number: 30012 Intellectual Property and Copyright This document includes registered and unregistered trademarks. All trademarks displayed are the
More informationModule de relais Relay Module. Manuel de l utilisateur 301RW. User Manual ERP /07
Module de relais Relay Module Manuel de l utilisateur 301RW User Manual ERP 511397 02/07 Relay Module 301R User Manual ERP 511397 2/07 Notices and Trademarks Copyright by Honeywell International Inc.
More informationRemote Chexit Module (RCM) System. General Information
*911032-00* 911032-00 Wiring and Configuration Remote Chexit Module (RCM) System Installation Instructions General Information The Von Duprin RCM is designed for controlled egress applications. It meets
More informationInstallation Requirements for Models:
900 & 9100 Series Refrigerators Installation Requirements for Models: 9162 9163 9182 9183 962 963 982 983 WARNING Improper installation, adjustment, alteration, service, or maintenance can cause injury
More information460H INSTALLATION & OPERATION MANUAL REMOTE STROBE POWER SUPPLY IMPORTANT: 460H TM REMOTE STROBE POWER SUPPLY
INSTALLATION & OPERATION MANUAL 460H TM REMOTE STROBE POWER SUPPLY 460H REMOTE STROBE POWER SUPPLY Contents: Introduction... 2 Standard Features... 2 Specifications... 2 Unpackaging & Pre-installation...
More informationInstallation and Operation Manual Low Power (LP) DC Power System
Installation and Operation Manual Low Power (LP) DC Power System LPS Power Enclosure LPB Battery Enclosure 2051259 R3 Information in this document is subject to change without notice and does not represent
More informationGalaxy Pulsar Plus Digital Battery Plant Controller
Galaxy Pulsar Plus Digital Battery Plant Controller Features Supports up to 60 Power Modules rectifiers and converters Supports dual voltage plants, with rectifiers and converters Auto-sensing dual voltage
More informationELECTRIC FLAT PANEL FIREPLACE HEATER
ELECTRIC FLAT PANEL FIREPLACE HEATER Model Numbers: WM50; WM-50-W; WS-G-01;WS-G-02 OWNER S MANUAL WARNING Read and understand this entire owner s manual, including all safety information, before plugging
More informationMulti-Graphic MCPB & Series 115B, 2223R, & 2233R
Multi-Graphic MCPB & Series 115B, 2223R, & 2233R Installation and User Manual 2009 Bogen Communications, Inc. All rights reserved. Specifications subject to change without notice. 54-5875-03B 0903 Notice
More informationMN908 No. 282C Replaces 282B LB7013
No. 282C Replaces 282B LB7013 Instruction Manual For Baldor Dust Control Units Models DC7, DC7 3, DC8, DC8 3, DC10, DC10 3, DC12, DC12 3 and DC14 3. For use on Grinders mounted to GA16 and GA20 pedestals
More informationAFMS Audible Flow Monitoring System TECHNICAL SPECIFICATION
968 AFMS AFMS TECHNICAL SPECIFICATION 08/07 Ref B ATV-ELEKTRONIK GMBH WIENER STRASSE 228 A-4030 LINZ +43 732 301600 FAX. +43 732 301600 21 Page 2 Table of contents General Introduction...3 Overview...3
More informationIlnstallat!on. nstruct=ons. Before You Begin. Parts Included. Tools Needed. Built-In Wall Oven with Microwave ATTENTION INSTALLER
Ilnstallat!on nstruct=ons Built-In Wall Oven with Microwave 27" (68.6 cm) model JKP90 30" (76.2 cm) models JTP90, PT970 If you have questions, call 1.800.GE.CARES or visit our website at: ge.com Before
More informationW8703A Damper Interface Module
W870A Damper Interface Module INSALLAION INSUIONS APPLIAION he W870A Damper Interface Module (DIM) controls up to three conventional zone dampers when used with Microelectronic ommunicating Programmable
More informationPump-Up Controller MODEL 4062
Pump-Up Controller 4-20mA Input/Scalable Output Seal Fail Monitoring Duplex Pump Alternation Hand-Off-Auto Controls Dual Run-time Meters RS-485/Modbus Communications DESCRIPTION The Model 4062 Pump-Up
More informationGDC 087R Issue 1 - May Installation and Operation UAS Network/Dropside Interface Unit Model NIU/DIU 7624.
GDC 087R707-001-01 Issue 1 - May 1998 Installation and Operation UAS 7000 Network/Dropside Interface Unit Model NIU/DIU General DataComm Manual Revision History Shown below is a chronological listing of
More informationAC/DC Power Supply and Battery Charger Installation and Maintenance
AC/DC Power Supply and Battery Charger Installation and Maintenance 61175043L3-5A Issue 1, January 2004 CLEI Code: SIMPAADA_ CLEI Code: SIMPAAGA_ CONTENTS 1. GENERAL... 1 2. DESCRIPTION... 1 3. INSTALLATION...
More informationMODEL ZAC ZONE ANNUNCIATOR/CONTROLLER DESIGNED FOR ZONE ANNUNCIATION AND MONITORING
MODEL ZAC-32 32 ZONE ANNUNCIATOR/CONTROLLER DESIGNED FOR ZONE ANNUNCIATION AND MONITORING 32 HARD WIRED ZONES CAN BE NORMALLY-OPEN OR NORMALLY-CLOSED ZONE WIRING RUNS CAN BE AS FAR AS 10,000 FEET FROM
More informationBeacon 410A Gas Monitor Operator s Manual
Beacon 410A Gas Monitor Operator s Manual Part Number: 71-0397 Revision: F Released: 12/5/17 www.rkiinstruments.com Product Warranty RKI Instruments, Inc., warrants gas alarm equipment sold by us to be
More informationQ7100A,C Thermostat Subbases
Q700A,C hermostat Subbases INSALLAION INSRUCIONS APPLICAION he Q700 hermostat Subbases provide electronic control of commercial 4 Vac single or multistage heat pump or conventional heating and cooling
More informationManage Alarms. Before You Begin CHAPTER
CHAPTER 8 Manage Alarms This chapter contains the procedures for viewing and managing the alarms and conditions on a Cisco ONS 15454. Cisco Transport Controller (CTC) detects and reports alarms generated
More informationInstallation Instructions
HHK Series Installation Instructions Electric Heater Kits Installation in Standard and Variable Speed Indoor Air Handlers! IMPOTANT: The instructions included with this heater kit are for installations
More informationACCURATE ELECTRONICS INC PO BOX SW HALL BLVD BEAVERTON OR USA FAX
Page 1 of 10 Model 10807800 January 2014 ACCURATE ELECTRONICS INC PO BOX 1654 97075-1654 8687 SW HALL BLVD 97008 BEAVERTON OR USA 503.641.0118 FAX 503.646.3903 WWW.ACCURATE.ORG Practice Section 10807800
More informationMODEL 8144-RD CLOCK SELECTOR/DISTRIBUTION AMPLIFIER INSTRUCTION MANUAL. SPECTRACOM CORPORATION 95 Methodist Hill Drive, Suite 500 Rochester, NY 14623
MODEL 8144-RD CLOCK SELECTOR/DISTRIBUTION AMPLIFIER INSTRUCTION MANUAL SPECTRACOM CORPORATION 95 Methodist Hill Drive, Suite 500 Rochester, NY 14623 PHONE 585-321-5800 FAX 585-321-5218 REVISIONS, IF ANY,
More informationImPress IRONING STATION
CONSUMER SERVICES TECHNICAL EDUCATION GROUP PRESENTS L-73 ImPress IRONING STATION Model LFB2611L JOB AID Part No. 8178203 FORWARD This Whirlpool Job Aid, ImPress Ironing Station, (Part No. 8178203), provides
More informationInstallation Manual COPYRIGHT NOTICE
Installation Manual COPYRIGHT NOTICE Copyright 2007 by Quest Controls Inc (QUEST). The material discussed in this publication is the proprietary property of QUEST. QUEST retains all rights to reproduction
More informationANC BBX-FXMNS or BBX Audio Network Controller Board Installation Instructions TNC-5000 ANC Module Mounting Locations
Audio Network Controller Board Installation Instructions Module Mounting Locations The Audio Network Controller board can be mounted in two places. One position is over the Audio Network Controller module
More informationPump-Down Controller MODEL 4052
Pump-Down Controller 4-20mA Input/Scalable Output Seal Fail Monitoring Duplex Pump Alternation Hand-Off-Auto Controls Dual Run-time Meters RS-485/Modbus Communications DESCRIPTION The Model 4052 Pump-Down
More informationGAS MONITOR Model Model
Sierra Monitor Corporation 1991 Tarob Court, Milpitas, CA 95035 (408) 262-6611 (800) 727-4377 (408) 262-9042 - Fax E-mail: sierra@sierramonitor.com Web Site: www.sierramonitor.com GAS MONITOR Model 2350-00
More informationProliphix Thermostat Installation Guide. Release 2.0
Proliphix Thermostat Installation Guide Release 2.0 July 2006 Beta Draft Confidential Technical Support When contacting Proliphix for technical assistance, please have the following information available:
More informationDESCRIPTIVE AND INSTALLATION INSTRUCTION MANUAL FOR MODEL AH1000, BH1000, AND EH1000 SERIES ANNUNCIATORS
DESCRIPTIVE AND INSTALLATION INSTRUCTION MANUAL FOR MODEL AH1000, BH1000, AND EH1000 SERIES ANNUNCIATORS SEEKIRK, INC. 2420 Scioto Harper Dr. Columbus, OH 43204 Tel: (614) 278-9200 FAX: (614) 278-9257
More informationInstallation Instructions Remote Blowers
Installation Instructions Remote Blowers Models: REMP3, REMP16 Suitable for use in a household cooking area. Suitable for use with solid state controls. To complete this blower, a Dacor hood assembly or
More informationNETWORK FIRE ALARM CONTROL PANEL. Features
NETWORK FIRE ALARM CONTROL PANEL FX-2009-12N Description FX-2009-12N in a BB-5008 enclosure. Mircom s FleX-Net TM FX-2009-12N Network Fire Alarm Control Panel offers modular components to meet a wide variety
More informationLORAIN CSP DC Power System
DC Power for Business-Critical Continuity Key Features Compact flexibility provides more space for revenue generating equipment Constant power delivers more current at lower voltages to meet load or recharge
More informationALARM OUTPUT MODULE. Product #7736
ALARM OUTPUT MODULE The Alarm Output Module (AOM) enables you to use weather station alarms or commands from your computer to automatically start or stop external devices such as indicator lights, audio
More informationGardian W51. Approvals
Gardian W51 120 V pre-assembled electric heating cables for pipe freeze protection and roof & gutter de-icing Installation Instructions Description Gardian W51 120 V pre-assembled self-regulating heating
More informationAir Storm Fans. Air Storm 54 Fiberglass Fan Installation and Operation Manual
Air Storm 54 Fiberglass Fan Installation and Operation Manual Table of Contents GrowerSELECT General Page... 3 Safety... 4 Warning Labels... 4 Installation... 5 Operation Safety... 5 Maintenance Safety...
More informationProduct Manual SZ2161. Description The SZ2161 is a microprocessor-based controller designed for water source heat pump plant control applications.
Product Manual SZ2161 Heat Pump Water Loop Controller Description he SZ2161 is a microprocessor-based controller designed for water source heat pump plant control applications. Features Stand-alone or
More informationINSTALLATION AND OPERATING INSTRUCTIONS. For Reliance Controls Emergency Power Transfer Switch Kit Model Number 30216BRK
INSTALLATION AND OPERATING INSTRUCTIONS For Reliance Controls Emergency Power Transfer Switch Kit Model Number 30216BRK Congratulations on your purchase of the Reliance Controls Generator Power Transfer
More informationModel 4880 Status Output Display Module Manual
Model 4880 Status Output Display Module Manual 1-2 150912 Section 1 Introduction The 4880 provides 16 switched outputs, 4 form C relay contacts, and an X10 module interface. See Table 2-1 for electrical
More informationINTELLIGENT FIRE ALARM AND AUDIO NETWORK SYSTEM. Features
INTELLIGENT FIRE ALARM AND AUDIO NETWORK SYSTEM Description Mircom s FleX-Net TM Series Network Fire Alarm Control Panels offer modular components to meet a wide variety of applications. Designed for peerto-peer
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS Keep these instructions with the boiler at all times. BOYERTOWN FURNACE CO. PO Box 100 BOYERTOWN, PA 19512 1-610-369-1450 www.boyertownfurnace.com 5-25-12 2 Danger Warning Caution
More informationInstallation Instructions
P700U -21NHP Base Non -Programmable Thermostats Installation Instructions Designed and Assembled in the USA. US patents: US20060165149 A1, USD578026 SI, US6205041 B1 A14005 Base Non---Programmable Thermostat
More informationDOG2 MEMS SERIES CAN J1939 INCLINOMETER
DOG2 MEMS SERIES CAN J1939 INCLINOMETER SPECIFICATIONS Dual axis inclinometer Measurement ranges ±90 CAN J1939 interface FEATURES 8 30 VDC supply voltage Digital signal processing includes o filter (e.g.
More informationDryAire DRYING CABINET
CONSUMER SERVICES TECHNICAL EDUCATION GROUP PRESENTS L-72 DryAire DRYING CABINET Model LMA1053L JOB AID Part No. 8178202 FORWARD This Whirlpool Job Aid, DryAire Drying Cabinet, (Part No. 8178202), provides
More informationEMS510 Electrical Wiring Guide Volume 2, Rev 1.4
EMS510 Electrical Wiring Guide Volume 2, Rev 1.4 Prepared by Michael L. Kominske Environmental Monitor Service Inc. PO Box 4340 Yalesville, CT 06492 Phone 203.935.0102 Fax 203.634.6663 Email: sales@emsct.com
More informationHigh-Speed Voice and Data Link Access Multiplexer
Telecommunications Group Section HVD-381-202 Equipment Issue 2 First Printing, August 2003 High-Speed Voice and Data Link Access Multiplexer CONTENTS PAGE Part 1. GENERAL.............................................................................
More informationInstallation Instructions
30" Built-In Wall Oven JTP20, JTP25, JTP28, JTP48, JTPh0, JT912, JT915, JT952, JT955, ZET938, ZET958 If you have questions, call 1.800.GE.CARES www.geappliances.com or visit our website at: Before You
More informationFW-RA-LED Remote Multiplex Annunciator Panels
FW-RA-LED Remote Multiplex Annunciator Panels WIRING and INSTALLATION INSTRUCTION LNOTICE All information, documentation, and specifications contained in this manual are subject to change without prior
More informationSTATUS ALARM HISTORY ALARM RESET
Instruction Manual Model 1582-42L Data Switch February 1999, Rev 0 CH1 AUTO CH2 SWITCH 1 2 1 2 STATUS 1 2 MODEL 1582 SWITCH CROSS TECHNOLOGIES INC. CH1 ONLINE MANUAL SELECT CH2 ONLINE SWITCH RESET MAN
More informationGreentrol Automation, Inc.
Model GA-100 Technical Manual GreenAlert 100 Series Greentrol Automation, Inc. Installation, Operation and Maintenance Technical Manual GA-100 Document Name: TM_GA-100_R1C TM_GA-100_R1C Part Number: 960--0000
More informationQ7300H Series 2000 Commercial Thermostat Subbases
Q700H Series 000 Commercial hermostat Subbases INSALLAION INSRUCIONS APPLICAION he Q700H hermostat Subbases are used with 700F hermostats to provide electronic control of commercial Vac single or multistage
More informationPROJ. NO SECTION PAGING, SPEAKERS AND HARD-WIRED CLOCK SYSTEMS
SECTION 26 92 50 PAGING, SPEAKERS AND HARD-WIRED CLOCK SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions
More informationAIC Series Float & Thermostatic Steam Trap Installation and Maintenance Instructions
AIC Series Float & Thermostatic Steam Trap Installation and Maintenance Instructions 138-EN Please read and save these instructions Contents General Safety Information... 3 Product Information...3-5 Product
More informationPublic Safety DAS Annunciator Panel
Public Safety DAS Annunciator Panel 120 VAC Models: 1221-A, 1221-B, 1221-C Revision D 91117 48 VDC Models: 1221-A-48, 1221-B-48, 1221-C-48 24 VDC Models: 1221A-24, 1221-B-24, 1221-C-24 CAUTION: (Read This
More informationQuick Alert Remote (QA216R)
Quick Alert Remote (QA216R) Description The QA 216 Remote is used by AT&T to monitor tower lights and turned down facilities. It is a 16-bit alarm unit used to transport discrete alarms from a remote location
More informationHow to add or upgrade residential & commercial equipment without installing new cables. How to test & repair cables.
Nordic Technology Ltd 1-800-775-4750 www.fast-stat.com This is the printer-friendly edition. o to www.fast-stat.com to download and print additional copies HVA iring Solutions How to add or upgrade residential
More informationERD97P21-U Receiver. Installation/ Operation Manual C939M-D (7/00)
ERD97P21-U Receiver Installation/ Operation Manual C939M-D (7/00) Pelco 3500 Pelco Way, Clovis CA 93612-5699 USA Pelco Online @ http://www.pelco.com In North America and Canada: Tel (800) 289-9100 or FAX
More informationINSTALLATION INSTRUCTIONS MODEL PA-250 AND PA-500 BOOSTER AMPLIFIER
273 Branchport Avenue Long Branch, N.J. 07740 (908) 222-6880 INSTALLATION INSTRUCTIONS MODEL PA-250 AND PA-500 BOOSTER AMPLIFIER GENERAL: The Series PA-250 and PA-500 Watt Booster Amplifiers are designed
More informationOhm Metrics. Instruction Manual. Continuous Workstation Monitors Model CM1600. T r a n s f o r m i n g T e c h n o l o g i e s, L L C
O u t s t a n d i n g A l t e r n a t i v e s i n S t a t i c C o n t r o l T r a n s f o r m i n g T e c h n o l o g i e s, L L C Ohm Metrics Continuous Workstation Monitors Model CM1600 Instruction Manual
More informationSentry LIQUID LEVEL GAUGE MODEL 200 or 200C OWNER MANUAL REV 1.7 SEPT08 PAGE 1 OF 12
PAGE 1 OF 12 TABLE OF CONTENTS PAGE 1. SAFETY PRECAUTIONS 1.1. Electrical shock 3 2. APPLICATION 3 3. INSTALLATION 3.1. Mount indoor alarm display 3.2. Mount the outdoor junction box 3.3. Install interconnecting
More informationINTELLIGENT FIRE ALARM CONTROL PANEL
INTELLIGENT FIRE ALARM CONTROL PANEL FX-2000 SERIES Description Mircom s FX-2000 Series Intelligent Analog Fire Alarm Control Panel is designed to provide maximum flexibility of analog system requirements
More information