File S789 Project 04ME December 20, 2005 REPORT CONTROL UNIT (UOJZ) * * * * * * * * * * * * * * * * * * * * *
|
|
- Reynold Murphy
- 6 years ago
- Views:
Transcription
1 File S789 Project 04ME15779 December 20, 2005 REPORT on CONTROL UNIT (UOJZ) * * * * * * * * * * * * * * * * * * * * * Complementary Product Categories CENTRAL STATION ALARM UNITS (AMCX, AMCX7) POLICE STATION ALARM UNITS (APAW, APAW7) Alarm Device Manufacturing Co. Syosset, NY Copyright 2005 Underwriters Laboratories Inc.
2 Underwriters Laboratories Inc. authorizes the above named company to reproduce this Report provided it is reproduced in its entirety.
3 File S789 Vol. 24 Sec. 2 Page 1 Issued: DESCRIPTION PRODUCT COVERED: USL, CNL - Control unit Model 7810iR-ent Internet Central Station Receiver. The Model 7810iR-ent ("AlarmNet") Internet Central Station Receiver when used with or without the separately Listed Model 685 digital receiver and associated protected premises units in order to provide central station fire for USL and burglar alarm service for USL/CNL. Can also provide Police- Connect service. For Central Station Fire Alarm Service, the Model 7810iR-ent must connect to a UL Listed Receiver/Central Station Automation System (Protective Signaling Service) which automatically annunciates unrestored, off-normal conditions during the 24 hour test report. Models 7810iR-ent is NIST Certified for encryption and are used in conjunction with models 7845i, 7845i-Ent, 8132 and 8142 premise equipment to provide encrypted line security. ENGINEERING CONSIDERATION: General - The product covered by this Report forms a portion of the Alarm Net I System. The unit allows the Listed 685 Receiver to connect to the internet to receive alarm signals from Alarm Net I or may be utilized as a stand alone Central Station Receiver. Remote Access features have not been evaluated by UL. This unit is to be powered by an appropriately rated Listed Commercial Fire Alarm Power Supply or UPS. See Installation Instructions for Power Supply ratings. Ratings - The 7810iR ENT unit is rated as follows: 12.0 Vdc 400 ma Component Servicing - All high-voltage parts within the units are insulated to prevent unintentional contact by service personnel. Evaluated in accordance with the following Standards: 1. UL 864 Eighth ("Control Unit for Fire Protective Signaling Systems"). 2. UL1610 (Central Station Alarm Units) 3. UL 365 ("Police Station-Connected Burglar Alarm Units and System"). 4. CAN/ULC-S304-M88 - Standard for Central and Monitoring Station Burglar Alarm Units. 5. NFPA 70 ("National Electrical Code"). 6. NFPA 72 National Fire Alarm Code. 7. In accordance with the requirements of the equipment installation literature and installation wiring diagram. 8. In accordance with any additional requirements imposed by the local authority having jurisdiction.
4 File S789 Vol. 24 Sec. 2 Page 2 Issued: CONSTRUCTION DETAILS: General - The general product design, shape and arrangement shall conform to that shown in the following photographs and associated descriptive pages, and the general product construction shall adhere to the following guidelines unless otherwise specifically indicated. Corrosion Protection - All ferrous metal parts shall be painted, plated or otherwise suitably coated to resist corrosion. Internal Wiring - All internal wiring shall be Labeled Appliance Wiring Material having 1/64 in. (0.04 mm) minimum insulation wall thickness or the equivalent, rated 300 V minimum and a temperature rating consistent with the intended operating environment. The wiring shall be arranged in an orderly fashion, routed away from moving parts and sharp projections and held in place with clamps, string ties or the equivalent unless of sufficient rigidity to maintain a shaped form. All internal wiring shall be routed, cabled and clamped as shown in the following photographs unless otherwise specifically indicated. Splice Connections - All splices and electrical connections shall be made mechanically secure and bonded electrically by soldering or by the use of Component Recognized splicing devices (wire connectors). A splice shall be provided with insulation equivalent to that of the wires involved if permanence of spacings between the splice and uninsulated metal parts is not assured. (See Spacings.) Splices shall be located, enclosed and supported so that the splice is not subject to damage, flexing, motion or vibration. Solder Connections - All joints and connections shall be made mechanically secure by twisting, bending, crimping or the like prior to soldering.
5 File S789 Vol. 24 Sec. 2 Page 3 Issued: Printed Wiring Boards - All printed wiring boards utilized in this product shall be fabricated of Recognized Component Printed Wiring Material (ZPMV2) having 1/16 in. (1.6 mm) nominal material thickness, a flammability rating of min 94V-2 and an operating temperature rating of 105 C or greater. If wave soldering techniques are employed, the solder bath temperature and duration as specified in the Recognition for the particular material being utilized shall not be exceeded. MARKING: General - All markings shall be plainly and permanently applied to a location readily visible after installation. They may be on the outside of the unit or may be behind a door or cover which may be opened or removed after installation. All markings shall utilize Recognized Component Marking and Labeling System Material (PGGU2). Nameplate - Contains Listee's name or registered trademark, model number designation, date code, reference to applicable NFPA Standards and reference to installation wiring diagram by drawing number and/or issue date. Controls - All user operated controls shall be adjacently marked to indicate function and position. Indicators - All visual indicators shall be adjacently marked to indicate function (exception LED s on right side of display are not utilized). The following markings shall also be provided: Electrical Ratings Terminals 1-9 are power limited For dry, indoor use only. Do not install in air-handling spaces For wiring information, See instructions K9581V2 Installation Wiring Terminals - The installation wiring terminals shall be adjacently marked to correspond with the installation wiring diagram and installation instructions unless complete installation instructions are provided at the installation wiring terminals. INSTALLATION LITERATURE: Installation Manual/Instructions for Model 7810iR-ent - Designated K9581 Rev A, Dated: 8/05.
6 File S789 Vol. 24 Sec. 2 Page 4 Issued: MODEL 7810iR FIG. 1 (M ) FIG. 1A (M ) 1. Enclosure - R/C (QMFZ2), ABS, Cycolac PLN6000, GE Plastics, 94V-0. (tested to the requirements for the 5 inch flame test in File S1632 Report 8/1/01). 206 x 50 x 12 mm. Min 2.3 mm thick. 2. Enclosure Back - Same as above 206 x 50 x 25 mm. Provided with a 63 x 45 mm opening for wiring, 4 keyhole slots for wall mounting, and 8 additional oblong holes for optional mounting methods. 3. PWB See construction details - Marked K5856 Rev LCD Screen - Sharp Liquid Crystal Display Model LM057QCTT03 5. High Voltage Transformer T2 - Cooper Electronic Technologies Model K4125 rated 900 V ac out. See Illustration 2 for details. 6. Transformer T1 - Designated K4159, marked CTX Coated copper wire wound on thermoplastic bobbin. Dimensions 11 mm x 5.5 mm. See Illustration 2 for details 7. Inductor L1 - Designated K4127, Coiltronics, Type CTX100-4 rated 100 mh. 8. Transformer T3 - Designated K4126, marked CTX Coated copper wire wound on thermoplastic bobbin. Dimensions 11 mm x 5.5 mm. See Illustration 2 for details. 9. Varistors - MOV1 to MOV8 (Designated N20-MOV22-1.5J) Mfg. by Keko- Varicon Type ZV14K R1, rated 22 V, 1.5 J. 10. Micro U7 - Designated N , Intel Type KU80386EX RJ45 Connector - R/C (DUXR2) 8 pin, soldered to PWB. 12. Insulation Sheet - Marked K5132V1 positioned over High Voltage circuit for display. Constructed of Kraft Paper min 0.90 mm thick, "Marked Warning High Voltage" 13. Software ( for encryption ) Alarm-Neti AES Encryption Software Module Version Capacitors See Illustration 3 for voltage and temperature ratings for all capacitors which shall be verified. All voltage and temperature ratings are considered minimum ratings and any decrease in voltage or temperature ratings requires further evaluation pin terminal block connector R/C XCFR2 rated min. 20 Vdc, Min 1 A. 16. Isolation Transformer (U28 Mfg. by Pulse Type PE Alternate Mfg. by Tamura Type TTC-8157
UL Electrical Equipment for Measurement, Control, and Laboratory Use; Part 1: General Requirements, Second Edition
File E315190 Project 07CA39477 March 5, 2008 REPORT on PROCESS CONTROL EQUIPMENT FOR USE IN HAZARDOUS LOCATIONS Litre Meter Ltd. Buckinghamshire, England Copyright 2008 Underwriters Laboratories Inc. Underwriters
More informationFile E Project 97SC January 21, 1998 REPORT
File E135803 Project 97SC15289 January 21, 1998 REPORT ON COMPONENT - POWER SUPPLIES, INFORMATION TECHNOLOGY EQUIPMENT, INCLUDING ELECTRICAL BUSINESS EQUIPMENT Condor DC Power Supplies Inc. Oxnord, CA
More informationUL TEST REPORT AND PROCEDURE
Issue Date: 2016-01-22 Page 1 of 9 Report Reference # E182560-V4-S48 UL TEST REPORT AND PROCEDURE Standard: ANSI/AAMI ES60601-1 (2005/(R)2012 + A1:2012, C1:2009/(R)2012 + A2:2010/(R)2012) - Amendment 1
More informationFile Ex643 Project 03NK31930 Project 04NK24425 Project 05NK25712 Project 06NK15719 Project 06NK06003 Project 06NK24531
WWW.UL.COM 1.877.ULHELPS / (1.877.854.3577) File Ex643 Project 03NK31930 Project 04NK24425 Project 05NK25712 Project 06NK15719 Project 06NK06003 Project 06NK24531 Issued: August 4, 2004 Revised: April
More informationSECTION (16460) - LOW-VOLTAGE TRANSFORMERS
PART 1 GENERAL 1.01 SUMMARY SECTION 26 22 00 (16460) - LOW-VOLTAGE TRANSFORMERS A. Section Includes: 1. Dry-Type Distribution And Specialty Transformers Rated 1000 V And Less. a. General-Purpose Distribution
More informationUL TEST REPORT AND PROCEDURE
Issue Date: 2016-01-26 Page 1 of 7 Report Reference # E182560-V4-S52 UL TEST REPORT AND PROCEDURE Standard: ANSI/AAMI ES60601-1 (2005/(R)2012 + A1:2012, C1:2009/(R)2012 + A2:2010/(R)2012) - Amendment 1
More informationIssued: January 13, 2006 Revised: April 21, 2009 REPORT. Automatic Sprinklers. The Viking Corporation Hastings, MI
File Ex643 Project 05NK21413 Project 06NK07102 Project 05NK31378 Project 06NK21906 Project 07NK02539 Project 06NK25809 Project 06NK27869 Project 07NK05434 Project 07NK05431 Project 07NK05106 Project 07NK15244
More informationJ-PRO TM Cable Support System
Frequently Asked Questions Cable Support System What references define how and where J-hooks are used? J-hooks are a horizontal pathway promoted in the BICSI TDM manual as a means to route small to medium
More informationListing Constructional Data Report (CDR)
Listing Constructional Data Report (CDR) 1.0 Reference and Address Report Number 3145135CRT-002 Original Standard(s) UL Standard for Safety for Inverters, Converters, Controllers and Interconnection System
More informationAPPLICATION NOTE. Introduction. Contents DMP DATA NETWORK CERTIFICATES APPLICATION NOTE
Contents Introduction...1 UL Approves Public Data Networks. 1 Analog communication... 1 DMP network communication... 2 AMCX Central Station Alarm Units.. 2 APAW Police Station Alarm Units... 2 APOU Proprietary
More informationTwo Circuit Heavy Duty Burner Connector
Product 108-1056 11 Oct.16 Rev B Specification EC 0990-0059-05 Two Circuit Heavy Duty Burner Connector 1. SCOPE 1.1. Content This specification covers performance, tests and quality requirements for the
More informationSLATE. Sub-Base Module INSTALLATION INSTRUCTIONS R8001S9001
SLATE Sub-Base Module R8001S9001 INSTALLATION INSTRUCTIONS Scan for more information Application SLATE brings configurable safety and programmable logic together into one single platform. The platform
More informationFile E Project 05ME Issued: November 1, 2005 Revised: February 27, 2009 REPORT
File E133400 Project 05ME09466 Issued: November 1, 2005 Revised: February, 2009 REPORT On COMPONENT POWER SUPPLIES, INFORMATION TECHNOLOGY EQUIPMENT INCLUDING ELECTRICAL BUSINESS EQUIPMENT TDK-Lambda Americas
More informationOJD ITB No Attachment E Duress Alarm Equipment Specifications
Duress Alarm Equipment Specifications PART 1 GENERAL 1.1 SECTION INCLUDES A. Duress devices. B. Alarm control panel. C. Signaling devices. 1.2 REFERENCE STANDARDS A. NFPA 70 - National Electrical Code;
More informationListing Constructional Data Report (CDR)
Listing Constructional Data Report (CDR) 1.0 Reference and Address Report Number HZ12070036-0 Original Portable Electric Luminaires ANSI/UL 153(12th Ed, rev. March 24, 21) Standard(s) Portable Luminaires
More informationFile Ex643 Project 95NK34821 Project 96NK19119 Project 97NK2995 Project 98NK20794 Project 99NK21353 *Project 03NK33
File Ex643 Project 95NK34821 Project 96NK19119 Project 97NK2995 Project 98NK20794 Project 99NK21353 *Project 03NK33 Issued: 1996-11-13 Revised: 2003-02-28 REPORT on SPRINKLERS, AUTOMATIC AND OPEN Viking
More informationSERIES VAC Microprocessor-Based Direct Spark Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION. Export Information (USA)
R SERIES 35-70 120 VAC Microprocessor-Based Direct Spark Ignition Control F-35-70 November 2015 FEATURES Safe start with DETECT-A-FLAME flame sensing technology Custom pre-purge and inter-purge timings
More informationPROTEUS Series OEL8000III-K. Tank Gauging System. Installation Manual
OMNTEC PROTEUS Series OEL8000III-K Tank Gauging System Installation Manual Page 1 of 23 PROPRIETARY INFORMATION NOTICE This document contains information and material developed by OMNTEC Mfg., Inc. All
More informationSECTION NURSE CALL SYSTEM
NURSE CALL SMARTCARE NURSE CALL SOLUTION Architectural Specifications Part 1 General SECTION 275223 - NURSE CALL SYSTEM 1.0 Summary 1.1 This section includes nurse call system and requirements for system
More information7800 SERIES RM7888A Relay Module
7800 SERIES RM7888A Relay Module SPECIFICATION DATA FEATURES APPLICATION The Honeywell RM7888A Relay Module is a microprocessor-based integrated burner control for industrial process semi-automatically
More informationMetasys System Extended Architecture Smoke Control UL 864 UUKL Compliance
Metasys System Extended Architecture Smoke Control UL 864 UUKL Compliance Checklist Code No. LIT-1201754 Release 1.2 Issued February 10, 2005 Document Introduction.................................................
More informationJan05 Rev A EC
Product Specification Two Circuit Heavy Duty Burner Connector 108-1056 12Jan05 Rev A EC 0990-0059-05 1. SCOPE 1.1. Content This specification covers performance, tests and quality requirements for the
More informationFile Ex643 Project 95NK34821 Project 96NK19119 Project 97NK2995 Project 98NK20794 Project 99NK21353 *Project 03NK33
File Ex643 Project 95NK34821 Project 96NK19119 Project 97NK2995 Project 98NK20794 Project 99NK21353 *Project 03NK33 Issued: 1996-11-13 Revised: 2003-02-28 REPORT on SPRINKLERS, AUTOMATIC AND OPEN Viking
More informationFort Rouge Leisure Centre Section HVAC Upgrades Phase 2 Page 1 of 5 Bid Opportunity No March 2013 FIRE ALARM SYSTEMS
HVAC Upgrades Phase 2 Page 1 of 5 Part 1 General 1.1 SUMMARY.1 Section Includes:.1 Materials and installation for fire alarm systems upgrades..2 Audible signal devices..3 End-of-line devices..4 Sustainable
More informationUL TEST REPORT AND PROCEDURE
Issue Date: 2010-12-01 Page 1 of 16 Report Reference # E252373-A31-UL UL TEST REPORT AND PROCEDURE Standard: Certification Type: CCN: Product: Model: Rating: UL 60950-1, 2nd Edition, 2014-10-14 (Information
More informationFile Ex643 Project 96NK8906 *Project 98NK Issued: January 31, 1997 Revised: October 21, 1999 REPORT SPRINKLERS, AUTOMATIC AND OPEN
File Ex643 Project 96NK8906 *Project 98NK20794 Issued: January 31, 1997 Revised: October 21, 1999 REPORT on SPRINKLERS, AUTOMATIC AND OPEN The Viking Corporation Hastings, MI Copyright 1997 Underwriters
More information7800 SERIES RM7888A Relay Module
7800 SERIES RM7888A Relay Module FEATURES SPECIFICATION DATA APPLICATION The Honeywell RM7888A Relay Module is a microprocessor-based integrated burner control for industrial process semi-automatically
More informationSLATE. Rectification Ampli-Check Flame Amplifier INSTALLATION INSTRUCTIONS R8001V1031
SLATE Rectification Ampli-Check Flame Amplifier R8001V1031 INSTALLATION INSTRUCTIONS Scan for more information Application SLATE brings configurable safety and programmable logic together into one single
More informationCERTIFICATION BULLETIN
File: ULC-S527-11 ULC-G5.2 June 1, 2012 CERTIFICATION BULLETIN 2012-04 Effective Date Announcement CAN/ULC-S527-11, 3 rd Edition of the Standard for Control Unit for Fire Alarm Systems To: Subscribers
More informationSECTION SOLAR PHOTOVOLTAIC (PV) POWER GENERATION SYSTEM
SECTION 48 14 14 SOLAR PHOTOVOLTAIC (PV) POWER GENERATION SYSTEM PART 1 GENERAL 1.1 SECTION INCLUDES The work of this section consists of furnishing a complete Solar Photovoltaic (PV) Power Generation
More informationCertificate of Compliance
FF0 001 Certificate of Compliance Certificate: 70116279 (LR 025993_0_000) Issued to: General Monitors, Incorporated 26776 Simpatica Circle Lake Forest, California 92630 USA Attention: Larry Vlagea The
More informationSPECIFICATION: AlarmLine TM INTELLIGENT LINEAR HEAT DETECTION
1. GENERAL SPECIFICATION 1.1 The contractor shall provide an Intelligent AlarmLine Linear Heat Detection System to perform the following functionality: A. Fire Alarm, Supervisory and Trouble-Event Initiation
More informationFile EX3836 Project 05CA54707 Project 06NK13655 Project 06NK29644 Project 06NK25809 Project 08CA19260 Project 07NK04786 Project 08CA42763 REPORT
File EX3836 Project 05CA54707 Project 06NK13655 Project 06NK29644 Project 06NK25809 Project 08CA19260 Project 07NK04786 Project 08CA42763 Issued: August 3, 2006 Revised: April 29, 2009 REPORT on RESIDENTIAL
More informationCSI Master Format 2004 Guide Specification for: Freezer Frost Heave Prevention (Mineral Insulated)
CSI Master Format 2004 Guide Specification for: Freezer Frost Heave Prevention (Mineral Insulated) System for preventing frost heave in freezers, cold rooms and ice arenas with temperature control, monitoring,
More informationSystem 350 S350A Temperature, S351A Humidity, and S352A Pressure Stage Modules
System 350 S350A Temperature, S351A Humidity, and S352A Pressure Stage s FANs 930, 125 Product/Technical Bulletin S350 Issue Date 0300 The S350A, S351A, and S352A Stage s are intended to be used with System
More informationB. Configuration of system shall be through Schneider Electric in Homewood, Illinois (Jerry Lanfear ).
SECTION 28 13 00 - ACCESS CONTROL PART I - GENERAL 1.1 SUMMARY A. This specification section describes the furnishing, installation, commissioning, and programming of a complete, turnkey, hardwired Andover
More informationSECTION LIGHTING CONTROLS
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 09 23 LIGHTING CONTROLS SPEC WRITER NOTE: 1. Delete between //----// if not applicable to project. Also, delete any other item or paragraph not applicable to
More informationSLATE. Base Module INSTALLATION INSTRUCTIONS R8001A1001
SLATE Base Module R8001A1001 INSTALLATION INSTRUCTIONS Scan for more information Application SLATE brings configurable safety and programmable logic together into one single platform. The platform can
More informationYP7999A1000 ControLinks Fuel Air Ratio Control Panel
YP7999A1000 ControLinks Fuel Air Ratio Control Panel FEATURES INSTALLATION INSTRUCTIONS Pre-wired and ready to install Includes the R7999A control, wiring subbase and S7999D1048 touchscreen display Commission,
More informationInverted Through Board Surface
Inverted Through Board Surface Application Specification Mount Technology (SMT) 114-13245 Connector Assembly 14 DEC 09 Rev E NOTE i All numerical values are in metric units [with U.S. customary units in
More informationSECTION C. Section Cable Trays for Electrical Systems: Additional identification requirements for cable tray systems.
SECTION 26 0553 PART 1 GENERAL 1.1 SECTION INCLUDES A. Electrical identification requirements. B. Identification nameplates and labels. C. Wire and cable markers. D. Voltage markers. E. Underground warning
More informationInstallation Instructions
Installation Instructions Type B Gas Vent Model E/R 3" 8" ECCO TYPE B GAS VENT AND ACCESSORIES ARE FOR USE ONLY WITH LISTED CATEGORY 1 GAS-FIRED APPLIANCES OR APPLIANCES LISTED FOR USE WITH TYPE B GAS
More informationSECTION AUTOMATIC TRANSFER SWITCHES PART 1 - GENERAL
SECTION 16400 AUTOMATIC TRANSFER SWITCHES 1.01 RELATED DOCUMENTS PART 1 - GENERAL A. Drawings and general provisions of Contract, including General Conditions and Division 1 Specification sections, apply
More informationelite Model ELN Centralized Emergency Lighting Inverter Systems 550 W to 1.5 KW Systems
5/25/16 rev 6 elite Model ELN General Specification 550 W to 1.5 KW elite Model ELN Centralized Emergency Lighting Inverter Systems 550 W to 1.5 KW Systems 1.0 General General Specification This specification
More informationSECTION LIGHTING CONTROL DEVICES
SECTION 16145 LIGHTING CONTROL DEVICES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification
More informationEVO192 v3.0 Fire and Burglary What s New
EVO192 v3.0 Fire and Burglary What s New Compatibility: EVO192 v3.0 TM50 v1.31 K641 v2.41 Overview: CP-01 Compliancy Wiring Diagram The following sections/options have been added to the EVO192 panel. They
More informationFile EX CA March 31, 2010 REPORT RESIDENTIAL SPRINKLERS. Viking Corp Hastings, MI. Copyright 2010 Underwriters Laboratories Inc.
File EX3836 09C39806 March 31, 2010 REPORT on RESIDENTIL SPRINKLERS Viking Corp Hastings, MI Copyright 2010 Underwriters Laboratories Inc. Underwriters Laboratories Inc. authorizes the above named company
More informationSECTION AIR COILS
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 23 82 16 AIR COILS SPEC WRITER NOTE: Delete between //---// if not applicable to project. Also delete any other item or paragraph not applicable in the section
More informationIsolated Thermocouple Module
User Manual for the HE693THM665, HE693THM666, HE693THM667, HE693THM668 Isolated Thermocouple Module Twelfth Edition 19 April 2004 PREFACE 19 APR 2004 PAGE 3 PREFACE This manual explains how to use the
More informationUL TEST REPORT AND PROCEDURE
Issue Date: 20110304 Page 1 of 12 Report Reference # E302267A32UL UL TEST REPORT AND PROCEDURE Standard: Certification Type: CCN: Product: Model: UL 606011, 1st Edition, 20060426 (Medical Electrical Equipment,
More informationMar11 Rev C
Product Specification 108-1441 11Mar11 Rev C Connector, Z-PACK*, 2 mm FB, Signal and Power 1. SCOPE 1.1. Content This specification covers performance, tests and quality requirements for the Z-PACK* 2mm
More information7800 SERIES 22-Terminal Universal Subbase
7800 SERIES 22-Terminal Universal Subbase FEATURES PRODUCT DATA Q7800B003/2003/U Metal Wall-mount subbase Q7800A005/2005/U Plastic Wall-mount subbase Quick-mount wiring subbase for all 7800 SERIES Relay
More informationSECTION ISOLATED POWER SYSTEMS
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 20 11 ISOLATED POWER SYSTEMS SPEC WRITER NOTE: Delete between //---// if not applicable to project. Also, delete any other item or paragraph not applicable to
More informationNetworX Series NX-870E Fire Supervision Module Installation and Startup
NetworX Series NX-870E Fire Supervision Module Installation and Startup 2002 GE Interlogix All rights reserved. Printed in the USA. NetworX is a trademark of GE Interlogix. These instructions do not purport
More informationGreentrol Automation, Inc.
Model GA-100 Technical Manual GreenAlert 100 Series Greentrol Automation, Inc. Installation, Operation and Maintenance Technical Manual GA-100 Document Name: TM_GA-100_R1C TM_GA-100_R1C Part Number: 960--0000
More informationCertificate of Compliance
FF0 001 Certificate of Compliance Certificate: 70116284 (LR 064969_0_00) Issued to: Mine Safety Appliances Company North American Division 1000 Cranberry Woods Dr Cranberry Township, Pennsylvania 16066-5296
More informationSECTION LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES (600 VOLTS AND BELOW)
SECTION 26 05 21 PART 1 - GENERAL 1.1 DESCRIPTION This section specifies the furnishing, installation, and connection of the low voltage power and lighting wiring. 1.2 RELATED WORK A. Excavation and backfill
More informationCU-02 with Senaco Plus
CU-02 with Senaco Plus Instruction Manual PL-509 July 2001 U-02 SENACO 33455090 Rev. 1.1 Safety Guidelines Warning notices must be observed to ensure personal safety as well as that of others, and to protect
More informationR7824, R7847, R7848, R7849, R7851, R7852, R7861, R7886 Amplifiers for 7800 SERIES and R7140 Relay Modules
R7824, R7847, R7848, R7849, R7851, R7852, R7861, R7886 Amplifiers for 7800 SERIES and R7140 Relay Modules PRODUCT DATA indicate the presence of flame when used with 7800 SERIES and R7140 Relay Modules.
More informationCOMMON WORK RESULTS FOR ELECTRICAL: Basic Electrical Materials Methods
1. BASIC ELECTRICAL MATERIALS 1. All conduit and raceway must be 3/4" or larger. Exposed raceway in finished areas shall be in 700 or larger wiremold. Exception: runs to individual devices 10 or less,
More informationKidde Nitrogen Inert Gas Clean Agent Fire Suppression System
1. GENERAL 1.1 INTENT OF SPECIFICATIONS A. This specification details the requirements for an engineered inert gas fire suppression system Model Kidde Nitrogen. These requirements, combined with good engineering
More informationMODEL B2 INSTALLATION MANUAL
RELEASE DEVICES GENERAL DESCRIPTION MODEL B2 INSTALLATION MANUAL S/N: The B2 Series Time Delay Release Devices are UL Listed, Canadian Listed, and CSFM Listed for use on rolling doors, single-slide and
More informationNFPA 2001: Standard for Clean Agent Fire Extinguishing Systems NFPA 70: National Electrical Code (NEC) NFPA 72: National Fire Alarm Code
Part 1 - GENERAL 1.1 DESCRIPTION OF WORK A. Design and installation of an engineered Kidde ECS Advanced Delivery Systems (ADS), clean agent/waterless fire suppression system employing 3M Novec 1230 waterless
More informationSERIES VAC Microprocessor-Based Intermittent Pilot Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION
R SERIES 35-703 120 VAC Microprocessor-Based Intermittent Pilot Ignition Control F-35-703 July 2016 FEATURES Safe start with DETECT-A-FLAME flame sensing technology Custom pre-purge and inter-purge timings
More information7800 SERIES EC7823/RM7823 Relay Module
7800 SERIES EC7823/RM7823 Relay Module FEATURES SPECIFICATION DATA APPLICATION The Honeywell EC7823/RM7823 is a microprocessor based Flame Detector Relay that can be fitted with any 7800 SERIES amplifier
More informationSimplex ES Network. ES Net Network Applications, Communications, Options and Specifications. ES Net features. UL, ULC Listed*
Simplex ES Network UL, ULC Listed* ES Net features ES Network (ES Net) is a high bandwidth (100 Mbps) IP based fire alarm network that supports up to 99 nodes and uses industry standard network technology
More informationSPACE DETECTOR SP Presentation
SPACE DETECTOR SP2-114 Presentation 1 CONTENTS 2 ULTRASOUND DETECTION 4 2.1 PRINCIPLE 4 2.2 FOR A PERFECT WORKING ORDER 4 3 DETECTOR PLACEMENT 5 3.1 PLACEMENT SITUATION 6 3.2 ZONE OF DETECTION 6 3.3 CITY
More informationSECTION P01 LIGHTING AND APPLIANCE PANELBOARDS - A-SERIES
PART 1 GENERAL A. The requirements of the Contract, Division 1, and Division 16 apply to work in this Section. 1.01 SECTION INCLUDES A. Lighting and appliance panelboards 1.02 RELATED SECTIONS A. 16475,
More informationAdvance Optima Continuous Gas Analyzers AO2060-Caldos15, -Caldos17, -Magnos106, -Uras14 Category 2G Analyzer Modules
Advance Optima Continuous Gas Analyzers AO2060-Caldos15, -Caldos17, -Magnos106, -Uras14 Category 2G Analyzer Modules Operator s Manual 42/24-12 EN Rev. 4 Contents Page Preface 4 Safety Information General
More informationHoneywell Durafit LED Retrofit Kit
Honeywell Durafit LED Retrofit Kit INSTALLATION INSTRUCTIONS LED RETROFIT LUMINAIRE CONVERSION FOR USE ONLY WITH PRODUCTS DESCRIBED AND INSTALLED IN ACCORDANCE WITH THE INSTRUCTIONS PROVIDED WITH THIS
More informationSubmittal Data Performance Data Electrical Data
ERMS Series Submittal Data Submittal Data Unit Designation: Job name: Architect: Engineer: Contractor: Performance Data Revision: 07/01/11 Cooling Capacity: EER: Heating Capacity: COP: Ambient Air Temp:
More informationCat 6 Shielded Patch cords
Product Specification 108-93010 14/Oct/2009 Rev E Cat 6 Shielded Patch cords 1. SCOPE 1.1 Content This specification describes performance and material requirements and tests procedures for AMP NETCONNECT*
More informationSLATE. UV Ampli-Check Flame Amplifier INSTALLATION INSTRUCTIONS R8001S1071
SLATE UV Ampli-Check Flame Amplifier R8001S1071 INSTALLATION INSTRUCTIONS Scan for more information Application SLATE brings configurable safety and programmable logic together into one single platform.
More informationSERIES VAC Microprocessor-Based Direct Spark Ignition Control with Inducer Blower Relay FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION
R SERIES 35-61 24 VAC Microprocessor-Based Direct Spark Ignition Control with Inducer Blower Relay F-35-61 August 2015 FEATURES Safe start with DETECT-A-FLAME flame sensing technology Custom pre-purge
More informationFIRE DEPARTMENT 9 METROTECH CENTER BROOKLYN, N.Y
dige of FIRE DEPARTMENT 9 METROTECH CENTER BROOKLYN, N.Y. 11201-3857 wew.vdertificate OF APPROVAL # 6167A (AMENDED) THIS CERTIFICATE IS REVOCABLE, NOT TRANSFERABLE and EXPIRES on OCTOBER 15, 2018 By order
More information7800 SERIES EC7885A/RM7885A Relay Module
7800 SERIES EC7885A/RM7885A Relay Module SPECIFICATION DATA 1. Torch-ignited main burner using the S445A Start-Stop Station, or any conventional knee or foot operated start-stop station. 2. Torch-ignited
More informationSECURITY ACCESS AND SURVEILLANCE SECTION VISTA 250BP ARCHITECT AND ENGINEER SPECIFICATION FOR SECURITY SYSTEM
SECURITY ACCESS AND SURVEILLANCE SECTION 13850 VISTA 250BP ARCHITECT AND ENGINEER SPECIFICATION FOR SECURITY SYSTEM ADEMCO Group 165 Eileen Way Syosset, New York 11791 1-800-645-7568 SECTION 13850 DETECTION
More informationA. This Section includes the following lighting control devices:
Attachment G LIGHTING CONTROL SPECIFICATIONS (Download Document separately) LIGHTING CONTROL SPECIFICATIONS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including
More informationIEC60601_1K. Medical electrical equipment Part 1: General requirements for basic safety and essential performance
Page 1 of 165 Report No.: E309264-D1028-1/A0/C0-UL Test Report issued under the responsibility of: IEC 60601-1 Medical electrical equipment Part 1: General requirements for basic safety and essential performance
More informationElectrical Safety Program
Electrical Safety Program Developed by: The Office of Environmental Health and Safety June, 2010 Table of Contents Introduction 3 Scope..3 Definitions.3-5 CSU Electrical Shop...5 Responsibilities.5-6 Employees.....5
More informationSECTION ELECTRICAL GENERAL PROVISIONS
PART 1 GENERAL 1.01 SECTION INCLUDES A. General provisions for Electrical Systems B. Wire and cable for 600 volts and less. C. Wiring connectors. D. Electrical tape. E. Heat shrink tubing. F. Wire pulling
More informationA. This Section includes the following lighting control devices:
SECTION 26 09 23 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply
More informationINSTALLATION, OPERATION AND MAINTENANCE MANUAL
GE Digital Energy Power Quality INSTALLATION, OPERATION AND MAINTENANCE MANUAL GE TRANQUELL Enhanced Thermal Protection (ETP) Series Integrally Mounted Medium and High Exposure Surge Protective Devices
More informationPRODUCT SPECIFICATION. 0.5mm Fine Stacking. Hermaphroditic Type BTB Connector
PRODUCT SPECIFICATION 108-115057 29OCT13 Rev. A1 0.5mm Fine Stacking Hermaphroditic Type BTB Connector 1. SCOPE 1.1. Content This specification covers performance, tests and quality requirements for 0.5mm
More informationSECTION FIRE ALARM SYSTEMS
SECTION 16721 FIRE ALARM SYSTEMS PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. The general provisions of the contract including General and Special Conditions and General Requirements shall apply to all work
More informationSECTION INTERIOR LIGHTING
SECTION 26 51 00 INTERIOR LIGHTING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationFull Service Central Station Fire Alarm Listing Evaluation
Full Service Central Station Fire Alarm Listing Evaluation Listing Evaluation A UL Listing project includes: 1. Evaluating the central station facility for compliance with UL 827, Central-Station Alarm
More informationR7824, R7847, R7848, R7849, R7851, R7852, R7861, R7886 Amplifiers for 7800 SERIES and R7140 Relay Modules
R7824, R7847, R7848, R7849, R7851, R7852, R7861, R7886 Amplifiers for 7800 SERIES and R7140 Relay Modules PRODUCT DATA indicate the presence of flame when used with 7800 SERIES and R7140 Relay Modules.
More informationGENERAL BULLETIN NO. 5397
ANSUL INCORPORATED ONE STANTON STREET MARINETTE, WI 54143-2542 715-735-7411 www.ansul.com GENERAL BULLETIN NO. 5397 DATE: August 20, 2008 TO: FROM: SUBJECT: All Authorized ANSUL Vehicle System s Distributors
More informationUltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW
12/23/16 Rev 9 UltraLITE Model ELU General Specification 4.2 KW to 5 KW UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW 1.0 General General Specification This specification describes
More informationAUTOGUARD Hubbell Self Test Ground Fault Circuit Interrupters. More innovation. More protection. More safety.
AUTOGUARD Hubbell Self Test Ground Fault Circuit Interrupters. More innovation. More protection. More safety. The GFCI that Tests Itself! You may forget, but Hubbell AutoGuard GFCI won't. Nothing delivers
More informationIR1xxx Series 1, IR2xxx Series 1 Miniature Infrared Gas Sensors for Hazardous Areas and Intrinsic Safety in Mining
IR1xxx Series 1, IR2xxx Series 1 Miniature Infrared Gas Sensors for Hazardous Areas and Intrinsic Safety in Mining FEATURES * Configured for carbon dioxide (IR11BD, IR21BD), hydrocarbons (,,, ) or acetylene
More informationInstruction Manual August sitrans CU 02
Instruction Manual August 2005 sitrans CU 02 Safety Guidelines: Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product and the connected equipment.
More informationPREFACE. Your comments or suggestions are welcome and appreciated. They should be sent to:
PREFACE Because of changes in installation codes, the increasing complexity of the equipment involved, and other factors, more and more markings are being used on electrical heating and cooling equipment.
More informationCORRELATION OF USE MARKING AND PRODUCT IDENTITY TEXT FOR NEW TYPE R LISTING MARKS
CORRELATION OF USE MARKING AND PRODUCT IDENTITY TEXT FOR NEW TYPE R LISTING MARKS The service for products in this file is transitioning from Type L to Type R with transition to be completed by December
More informationSENTRY PRODUCTS, INC. 01/98 SCAN - STAND-ALONE - Sample Specification
This sample specification is for a duress only stand-alone SCAN system using SR series receivers with zone-within-a-zone and graphic display. SECTION 17 DURESS SYSTEM PART 1.00 - GENERAL 1.01 DESCRIPTION
More informationLED Flex Tube Assembly Guide
LED Flex Tube Assembly Guide WARNING: NEVER APPLY POWER TO FLEX TUBE WHILE COILED!!! Please read entire guide before beginning assembly or installation. Licensed electricians should provide all electrical
More informationAUTO RESET ALARM RELEASE BOX MODEL AR-C INSTRUCTION MANUAL
AUTO RESET ALARM RELEASE BOX MODEL AR-C INSTRUCTION MANUAL AR C Rev.06 WARNING 1. CAUTION: Review all installation instructions, procedures, cautions and warnings contained within this manual prior to
More informationAES IntelliTAP. Model 7068 Digital Dialer Interface A Supplemental Alarm Reporting Device. Version Installation Guide CONTENTS
AES IntelliTAP Satellite / Remote Dialer Data Receiver Page 1 AES IntelliTAP Model 7068 Digital Dialer Interface A Supplemental Alarm Reporting Device Version 1.10 Installation Guide CONTENTS How it Works
More informationEL7611A/EL7612A Ultrasonic Occupancy Sensors and EL7621A Power Pack PRODUCT DATA
EL7611A/EL7612A Ultrasonic Occupancy Sensors and PRODUCT DATA Proven 30% to 60% utility cost savings because lights are on only when needed. Low initial cost allows fast payback. Models available for 1000
More information