That s The Metal-Fab Way Experience The Difference
|
|
- Egbert Bennett
- 6 years ago
- Views:
Transcription
1 1
2 Faster. Safer. etter. Metal-Fab provides complete and comprehensive venting solutions to the HV, hearth and plumbing markets. Founded in 1959, on the premise that better products and services would be the key to our success. Metal-Fab continues to operate today as a privately held entity with the same core values that lead to success while creating steady, stable growth over the past six decades. ustomer needs are the highest priority at Metal-Fab, and that is why every customer receives a unique experience while choosing from a full line of high-quality venting products for residential, commercial and industrial applications. utting-edge manufacturing systems, innovative designs, patented products, unmatched product quality, and a focus on detail has resulted in a leadership position within the industries Metal-Fab serves. Our constant product improvement process and experience in developing and engineering products for safe, efficient appliance operation sets Metal-Fab apart from the competition. Our superior customer service, 1-2 day shipping, and 100% order fill make Metal-Fab the choice for all your venting requirements. That s The Metal-Fab Way Experience The Difference SFETY ESE Product Quality Engineered for safety & efficiency. Installation Safety Hemmed flue & casing. Zero Height Increaser No-height increaser design, no additional space required. Positive Twist-Lock onnection UL listed to adapt to identified competing -Vent brands. 2 UL Product ertification Products tested and listed to UL441 requirements to ensure safety and efficiency. SureLock Locking System No sheet metal screws required. Swivel Tees & Wyes 360 rotating male connection for easy installation. Easily djustable 45/60 Elbows 360 rotating collar, 4-piece design saves cost of 90 elbow.
3 onvenience 1-2 Day Shipping Order onfirmation & Tracking Regional Warehouse Locations One-Stop Vent Shopping omplete lines of HV, Hearth & Plumbing products and accessories. 100% Order Fill ustomer Service & Support World-class customer service, responsive to your needs. Friendly representatives to assist with design, project layout, job quotes and submittals. Innovative and talented marketing staff to assist in marketing Metal-Fab products. Products You an Trust! Manufacturing Superior Quality Venting Products For Over 60 Years! Qualified factory technical support department. Temp/Guard Premium iomass SuperFlex Stainless Steel Liners Fire & eiling Radiation Dampers Direct Vent lack Stovepipe orr/guard Grilles, Registers & Diffusers omplete lines of HV, Hearth & Plumbing products to meet your needs for any installation. 3
4 UL Listed -Vent daptability Have you ever been in the field and don t have the brand of -Vent you need? Metal-Fab understands and that is why we have come up with a solution to save you time and money. Existing -Vent installations frequently require repair, replacement and maintenance as we all know. What should you do if the existing product make and model cannot be identified with certainty? Let Metal-Fab solve your problems. Our -Vent 3 through 6 is UL listed to adapt to any competitor s UL listed -Vent products. Metal-Fab s universal adaptability with identified competing brands provides a competitive advantage in the field and you the installer only need one brand of -Vent. Installing Replacement Equipment (3-6 ) Mating two different brands of -Vent does not have to cost you time and money. Metal-Fab -Vent provides a solution in two easy steps. Simply, insert the male end (outlet) of the competitive -Vent brand into the female end (inlet) of the Metal-Fab adapter, then tighten the adapter clamp. Male dapter (Part # - M6, M12, M18) LISTED MH7860 4
5 Depleting ompetitive Inventory Metal-Fab is the only -Vent manufacturer with UL approval to connect the male end into the female end of all competitive UL listed -Vent brands, increasing product versatility. Did you know that by simply connecting using three (3) quarter inch sheet metal screws to secure creates a UL listed connection? No dapter Required Metal-Fab round -Vent has been evaluated and listed to Underwriters Laboratories to mate with other specifically identified UL listed round gas vent in 3 through 6 diameters. Metal-Fab s approval includes but is not limited to the following -Vent products: merican Metal Products o. ontinental Industries, Inc. EO Manufacturing Hart & ooley, Inc. M&G Duravent Inc. Mitchell Metal Products, Inc. Selkirk orporation (merivent) (irjet) (Model E/R) (Hart & ooley -Vent) (Type Gas Vent) (Mitch Vent) (Energy Vent) Female dapter For those installing specialists and building authorities who may prefer the use of a female adapter in contrast to connecting using sheet metal screws. The female adapter is adjusted and the adapter clamp is tightened to the competitive brand of -Vent. (Part # - M6F) 5
6 TOLL FREE Flex Metal-Fab s double wall -Flex can be used as a connector or as a segment of -Vent in a variety of installations. pplications Use -Flex anywhere -Vent is required, except where pipe penetrates the structure walls, floors, ceilings or roof. USED S ONNETOR USED IN RWL SPE Flexible double wall for easy -Vent pipe fitting. Make a direct connection from one or both appliances to a common -Vent. USED IN TTI Easily connect a furnace located in a crawl space to a rigid -Vent penetration. USED THROUGH N TTI Make a quick connection from an attic furnace to a rigid -Vent penetration. onnect a furnace to a termination on a conventional installation with ease. 6 Faster. Safer. etter.
7 TOLL FREE Double Wall Versatility, Flexible dvantages. Quick & Easy -Flex eliminates measuring, special adapters and assembly of rigid pipe lengths. ost Savings Saves time and labor, a universal solution to connecting appliances to rigid -Vent. onvenience Ready to install right out of the box with factoryassembled male and female positive twist-lock ends. daptability an be used with other specifically identified competing brands of UL listed round gas vent 3 through 6 diameters. UL listed for use as connection from the appliance to rigid Type- gas vent, and as a segment of -Vent. Listed Metal-Fab s approval includes connections at both the male (outlet) and female (inlet) end to the following -Vent products but is not limited to: merican Metal Products o. (merivent) ontinental Industries, Inc. (irjet) EO Manufacturing (Model E/R) Hart & ooley, Inc. (Hart & ooley -Vent) M&G Duravent, Inc. (Type Gas Vent) Mitchell Metal Products, Inc. (Mitch Vent) Selkirk orporation (Energy Vent) t the male (outlet) end of the compatible gas vent, add an adapter or adjustable length (M6, M12, M18) then add sections of Metal-Fab -Vent pipe. t the female (inlet) end of the compatible gas vent, simply insert the male end of the Metal-Fab -Vent into the compatible gas vent and secure per installation instructions. 7
8 TOLL FREE SureGrip Vent Support Plate The fastest, easiest way to support -Vent where it penetrates floors and ceilings..just a few minutes and you re finished! ut the hole. Standard SureGrip Mount SureGrip support plate. Typical two-story installation Standard SureGrip djustable SureGrip Push pipe through vent support. Standard SureGrip vailable for 3 through 8 diameter -Vent. 8 ontinue adding pipe sections supports up to 90 lbs.
9 TOLL FREE djustable SureGrip Vent Support Plate Holds pipe in a secure position as it penetrates through the roof..an t be accidentally pushed down through the roof! ut the hole. djustable SureGrip Mount SureGrip support plate. Typical attic appliance installation Push pipe through vent support. djustable SureGrip vailable for 3 through 6 diameter -Vent. ontinue adding pipe sections supports up to 90 lbs. Fast, sure, support that s easy, trouble-free and won t let the pipe slip! 9
10 MTERIL SPEIFITIONS The outer wall is constructed of galvanized steel,.018" thick G-90 for sizes 3" to 14" diameter, and.024" thick G-90 for sizes 16" to 30" diameter. The inner wall is constructed of aluminum alloy,.012" thick for sizes 3" to 8" diameter and.018" thick for sizes 10" to 30" diameter. The vent includes an integral, annular insulating air space, ¼" thick for sizes 3" to 6" diameter and ½" thick for sizes 7" to 30" diameter. DPTILITY Metal-Fab round -Vent has been evaluated and listed by Underwriters Laboratories, Inc., to mate with other specifically identified and UL listed round gas vent, in 3" through 6" diameters. Metal-Fab's approval covers connections at both the male (outlet) end, and the female (inlet) end to the following -Vent products: merican Metal Products o. ontinental Industries, Inc. EO Manufacturing Hart & ooley, Inc. M&G Duravent, Inc. Mitchell Metal Products, Inc. Selkirk orporation (merivent) (irjet) (Model E/R) (Hart & ooley -Vent) (Type Gas Vent) (Mitch Vent) (Energy Vent) t the male (outlet) end of compatible gas vent, add an adapter or adjustable length (M6, M12, or M18) - then add sections of Metal-Fab pipe. t the female (inlet) end of compatible vent simply insert the male end of Metal-Fab -Vent into the compatible gas vent and secure per instructions. 10
11 TOLL FREE TYPE - GS VENT - ROUND PIPE Note: Vent overlaps 1.5" when joined together. Therefore, assembled length is 1.5" less than listed length. PIPE LENGTHS -- 3M through 14M With positive twist lock. I.D. DIMETER to 6 X X X X X X X 7 to 10 X X X X X X 12 to 14 X X X X I.D. = 3 through 14 diameter. = Length. See chart for available lengths. SureLock is standard on 3"-6" diameters. PIPE LENGTHS -- 16M through 30M With quick connect lock using sheet metal screws. I.D. DIMETER to 30 X X X X I.D. = 16 through 30 diameter. = Length. See chart for available lengths. DJUSTLE LENGTHS M12 - M18 T. NO. I.D. M12 djusts from 3 to 8 3 through 30 M18 djusts from 3 to 14 3 through 30 DPTER M6 T. NO. I.D. M through 8 DPTER M6F T. NO. I.D. M6F through 6 11
12 TYPE - GS VENT - ROUND PIPE 90 DJUSTLE ELOW M90-3 through 8 D T. NO. SIZE D 3M M M M M M The five piece M90 short radius elbow is fully adjustable from 0 (straight) to 90. The 360 rotating collar allows for desired orientation of vent pipe. SureLock is standard on 3"- 6" diameters. 45 /60 DJUSTLE ELOW M45/60-3 through 8 T. NO. SIZE D D 3M45/ M45/ M45/ M45/ M45/ M45/ In sizes 3 through 8, the four piece M45/60 short radius elbow is fully adjustable from 0 (straight) to 60. The 360 rotating collar allows for desired orientation of vent pipe. SureLock is standard on 3"- 6" diameters PIEE ELOW M45-10, 12, 14, PIEE ELOW M45-18 through 30 D E T. NO. SIZE D E F G 10M M G F 14M M M M Fixed 45 2-piece elbow shown. 22M M M D E 28M M G F Note: 10, 12 and 14 elbows are adjustable, and these same diameters have positive twist lock. Fixed angles in 16 through 30 diameter have quick connect lock using sheet metal screws. 12
13 TOLL FREE TYPE - GS VENT - ROUND PIPE 360 D SureLock is standard on male end on 3"- 6" diameters. T. NO. SIZE D 3M3ST M4ST M4ST M5ST M5ST M5ST M4ST M4ST M6ST M6ST M6ST M6ST M5ST M5ST L * T. NO. SIZE 7MT MT MT MT MT MT MT MT MT MT MT MT MT E D SureLock is standard on male end on 3"- 6" diameters. T. NO. SIZE D E 4M4SY M4SY M5SY M5SY M4SY M4SY M6SY M6SY M6SY M5SY M5SY M4SY
14 TYPE - GS VENT - ROUND PIPE T. NO. SIZE 3MHP MHP MHP MHP SureLock is standard on 3-6 diameters. T. NO. SIZE 7M M M M With positive twist lock. T. NO. SIZE 3MUHP MUHP MUHP MUHP
15 TOLL FREE TYPE - GS VENT - ROUND PIPE T. NO. SIZE 7MU MU T. NO. SIZE D 14M D 16M M M M M M M M Note: 14 has positive twist lock has quick connect lock. 15
16 TYPE - GS VENT - ROUND PIPE NO-HEIGHT INRESER - MIN 2.68 T. NO. 3MIN MIN MIN INRESERS MIX 4-14 T. NO. SMLL END LRGE END HT T. NO. SMLL END LRGE END HT. 4" through 14" 3MIx MIx ?MIx7 Specicified ?MIx8 Specicified ?MIx10 Specicified ?MIx12 Specicified ?MIx14 Specicified ?MIx16 Specicified ?MIx18 Specicified ?MIx20 Specicified ?MIx22 Specicified ?MIx24 Specicified ?MIx26 Specicified ?MIx28 Specicified ?MIx30 Specicified " through 30" MOTOR HOUSING DPTERS T. NO. 3D D M 3D M M M M D With Single Wall Outlet M With Double Wall Outlet For connection to plastic motor housing. 16
17 TOLL FREE TYPE - GS VENT - ROUND PIPE T. NO. SIZE T. NO. SIZE 3MD MD MD MD MD MD MD MD MD MD MD MD MD MD MD MD MD ESYOUT TM DRFTHOOD ONNETOR 4MD onnects to a furnace s internal vent elbow and exits the cabinet, where -Vent can then be connected. Designed for specific arrrier, ryant and Payne gas furnaces, see spec sheet for models. DRFTHOOD INRESER 3MD For increasing a 3 drafthood outlet to a 4 -Vent outlet. SINGLE WLL FLEX ONNETORS MSWF - 3 through 5 I.D. T. NO. SIZE MSWF03 3 1, 2, 3, 4, 5 MSWF04 4 1, 2, 3, 4, 5 MSWF05 5 1, 2, 3, 4, 5 For easy connection of appliance to common -Vent. TM I.D. 6 T. NO. SIZE MDWF03 3 2, 3, 4, 5 MDWF04 4 2, 3, 4, 5 MDWF05 5 2, 3, 4, 5 MDWF06 6 2, 3, 4, 5 Use as a connection of appliance to common -Vent or as a segment of -Vent except where it penetrates the structure: walls, floors, ceilings, roof. P RTITION THIMLE MPT - 3 through 8 T. NO. SIZE 3MPT MPT MPT MPT MPT MPT djust from 4.00 to 6.50 for variable wall thickness. 17
18 TYPE - GS VENT - ROUND PIPE HNGER/WLL ND MH T. NO. SIZE 3MH MH MH MH MW and 8MW still available, see price sheet. FIRESTOP MFS T. NO. SIZE 3MFS MFS MFS MFS MFS MFS Spacer ring attached to plate ensures 1 clearance to combustibles. SUREGRIP VENT SUPPORT PLTE - MVSP T. NO. SIZE 2MVSP MVSP MVSP MVSP MVSP MVSP MVSP The fastest, easiest way to support -Vent where it penetrates floors and ceilings Note: Pipe not included SUREGRIP VENT SUPPORT PLTE DJUSTLE - MVSP DI. T. NO. SIZE 3MVSP MVSP MVSP MVSP Note: Pipe not included. 18
19 TOLL FREE TYPE - GS VENT - ROUND PIPE TEE P MT Sizes 3 through 30 Use to cap flue when tee has no bottom (inlet) entry. SUPPORT PLTE MSP T. NO. SIZE T. NO. SIZE 3MSP MSP MSP MSP MSP MSP MSP MSP MSP MSP MSP MSP MSP MSP MSP MSP MSP HEVY SUPPORT MHS - 10 through 30 GUY RING MGR T. NO. SIZE 10MHS MHS MHS MHS MHS MHS MHS MHS MHS MHS MHS Designed to support large size pipe sections. lso serves as a firestop. Sizes 10 through 30 For additional support above the roof. 120 TYP. 19
20 TYPE - GS VENT - ROUND PIPE STNDRD FLSHING MF 4.00 T. NO. SIZE PLTE 3MF x MF x MF x MF X MF X MF X MF X MF X MF X Fits roof pitch 2/12 to 5/12. T. NO. SIZE PLTE 16MF X MF X MF X MF X MF X MF X MF X MF X /12 FLSHING MF T. NO. SIZE PLTE 3MF x MF x MF x MF x MF X Oval x MF X Oval x Fits roof pitch 6/12 to 12/12. TLL ONE FLT FLSHING MFT T. NO. SIZE PLTE T. NO. SIZE PLTE MFT x MFT x MFT x MFT X MFT X MFT X MFT X MFT X MFT X MFT X MFT X MFT X MFT X MFT X MFT X MFT X MFT X Flat roof flashing 20
21 TOLL FREE TYPE - GS VENT - ROUND PIPE T. NO. SIZE 3MV MV MV MV MV MV T. NO. SIZE 3MS 3 4MS 4 5MS 5 6MS 6 7MS 7 8MS 8 10MS 10 12MS 12 14MS 14 T. NO. SIZE 16MS 16 18MS 18 20MS 20 22MS 22 24MS 24 26MS 26 28MS 28 30MS WTERPROOF - Will not harden or oxidize from weather. NON TOXI Dimensions are 1/16 in thickness by 5/8 width. 25 feet to the roll. 21
22 TYPE - GS VENT - ROUND PIPE OVL PIPE MO - 4 thr ough 6 T. NO. SIZE LENGTHS 4MO , 12, 18, 24, 36, 48, 60 5MO , 12, 18, 24, 36, 48, 60 6MO , 12, 18, 24, 36, 48, 60 4 & 5 oval fit 2 x 4 or 2 x 6 stud walls. 6 oval fits 2 x 6 stud wall. OVL DJUST LE LENGTH MO12 T. NO. SIZE LISTED LENGTH 4MO MO MO MO12 adjusts from 3 to STNDRD FIXED NGLE MO45S T. NO. SIZE OFFSET 4MO45S MO45S MO45S FLT FIXED NGLE MO45F T. NO. SIZE OFFSET 4MO45F MO45F MO45F
23 TOLL FREE TYPE - GS VENT - ROUND PIPE DPTER: ROUND TO OVL MRO DPTER: OVL TO ROUND MOR T. NO. OVL SIZE ROUND SIZE T. NO. 4MRO MOR 5MRO MOR 6MRO MOR 6MRO MOR5 OVL TEE MOT T. NO. D 4MOT MOT MOT MOT D OVL VENT P MO T. NO. SIZE 4MO MO MO OVL DJUSTLE ROOF FLSHING MOF MIN. T. NO. SIZE 4MOF 4 5MOF 5 6MOF 6 Fits flat to 5/12 roof pitch. 23
24 TYPE - GS VENT - ROUND PIPE OVL TEE OVL STORM 0LLR -- MOS T. NO. SIZE 4MOS MOS MOS OVL TEE P -- MOT T. NO. 4MOT 5MOT 6MOT OVL TEE SUPPORT -- MOTS 2.50 T. NO. 4MOTS 5MOTS 6MOTS 0.50 Sizes 4 through 6 Use to cap flue when tee has no bottom (inlet) entry. Sizes 4 through 6 OVL FIRESTOP SPERS -- MOFS, MOFS T. NO. 4MOFS 5MOFS 6MOFS T. NO. 4MOFS6 5MOFS6 Sizes 4 through 6 Fits space between studs 16 center. Note: Model MOFS6 is for 2 x 6 stud wall W INSTLLTION KIT -- MOK -- 4 ONLY T. NO. 4MOK Kit Includes: 4PS eiling Spacer Plates (2) 4P ase Plate (1) Gasket (1) For venting recessed wall heaters. The installation kit adapts 4 MO pipe for use with wall furnaces Metal-Fab, Inc. Litho in U.S.. Faster. Safer. etter. P.O. OX 1138 WIHIT, KS FX info@metal-fabinc.com Form No. L941 2/
DURAVENT POLYPRO VENTING PRODUCTS
DURVENT POLYPRO VENTING PRODUCTS INDEX FLEX VENTING SYSTEM DPTER KIT... 14-11 -VENT RETROFIT DPTERS... 14-10 CHIMNEY CP... 14-10 CHIMNEY LINING KIT... 14-10 CHIMNEY SUPPORT... 14-11 COUPLER DPTER... 14-12
More informationDuraPlus HTC. All-fuel, double-wall chimney system. ULC S629.
DuraPlus HTC ll-fuel, double-wall chimney system. ULC S629. Specifications pplications DuraPlus HTC is a double-wall, all-fuel chimney system for both the U.S. and Canada for use with wood stoves; fireplaces;
More informationCombustion Air System DVL. DuraBlack. Triple-wall stovepipe system designed to provide air for combustion through its components. ULC S641.
Combustion ir System Triple-wall stovepipe system designed to provide air for combustion through its components. ULC S641. DVL Double-wall interior close clearance stovepipe for connecting woodstoves to
More informationCVS. Venting System for Category II, III, and IV gas appliances. Listed to UL-1738 and ULC S636.
VS Venting System for ategory II, III, and IV gas appliances. Listed to UL-1738 and UL S636. PelletVent venting system. Listed to UL 641, UL S609, and UL/ORD 441. Unitized venting system for DirectVent
More informationPelletVent Pro. Biofuel venting system. UL 641, ULC S609, and ULC/ORD C441.
PelletVent Pro iofuel venting system. UL 641, ULC S609, and ULC/ORD C441. Specifications pplications PelletVent Pro is a venting system designed for stoves and inserts that use wood pellets and oil fuel.
More informationPelletVent Multi-fuel venting system. UL 641.
PelletVent Multi-fuel venting system. UL 641. Specifications Applications PelletVent is designed for venting of pellet stoves and inserts. Consult appliance manual for additonal requirements. Materials
More informationC. Manufactured double wall chimneys for fuel fired equipment. D. NFPA 54 - National Fuel Gas Code; National Fire Protection Association; 2009.
SECTION 235100 - BREECHINGS, CHIMNEYS, AND STACKS PART 1 GENERAL 1.1 SECTION INCLUDES A. Fabricated breechings. B. Manufactured chimneys for gas fired equipment. C. Manufactured double wall chimneys for
More informationflexible venting simply perfect cost efficient convenient durable Est FREEDOM VENTING FLEX
flexible venting simply perfect cost efficient convenient durable Est. 1990 FLEX FREEDOM VENTING Introduction Freedom Flex Venting systems are top of the line when it comes to materials, cost efficiency
More informationCombustion Air System DVL. DuraBlack. Triple-wall stovepipe system designed to provide air for combustion through its components. ULC S641.
System Triple-wall stovepipe system designed to provide air for combustion through its components. ULC S641. DVL Double-wall interior close clearance stovepipe for connecting woodstoves to chimney. ULC
More informationDirect Vent System. for PELLET STOVES FEATURES. Includes all Selkirk Model VP Pellet Pipe and Direct-Temp components needed to complete a system
CTLOG Direct Vent System for PELLET STOVES Includes all Selkirk Model VP Pellet Pipe and Direct-Temp components needed to complete a system Direct-Temp for pellet stoves is the revolutionary, high-performance
More informationDirectVent Pro CVS. Unitized, co-axial venting system for direct vent gas or propane stoves, and fireplaces.
DirectVent Pro Unitized, co-axial venting system for direct vent gas or propane stoves, and fireplaces. VS Venting System for ategory II, III, and IV gas appliances. Listed to UL-1738 and UL S636. Specifications
More informationPellet Stove. Flex Pipe. Appliance Connector
Installation Instructions & Owners Maintenance Guide DT-M Direct-Temp for Multi Fuel L-Vent / Vent System for Pellet, Corn and other Bio-Fuel Burning Appliances Introduction Direct-Temp for Multi-Fuel
More informationBring In the Fresh Air
ring In the Fresh Air ombustion Air System For DuraTech, DuraPlus HT and PelletVent Pro DuraVent s new, exclusive, patentpending DuraPro ombustion Air System Wall Thimble and eiling Support oxes is the
More informationBy Bernard Dalsin Mfg. Co. Installation and Operating Instructions Read these instructions and keep them for future reference
By Bernard Dalsin Mfg. Co. 5205 208 th St Farmington MN 55024 L-VENT TYPE 3 "and 4" Factory-built venting system for wood pellet, corn or biomass and low-temperature gas or liquid fuel appliances Installation
More informationInstallation Instructions
Installation Instructions Type B Gas Vent Model E/R 3" 8" ECCO TYPE B GAS VENT AND ACCESSORIES ARE FOR USE ONLY WITH LISTED CATEGORY 1 GAS-FIRED APPLIANCES OR APPLIANCES LISTED FOR USE WITH TYPE B GAS
More information5"x 8" DIRECT VENT INSTALLATION INSTRUCTIONS FOR DECORATIVE GAS APPLIANCES AND DIRECT VENT HEATERS APPLICATION
5"x 8" DIRECT VENT INSTALLATION INSTRUCTIONS FOR DECORATIVE GAS APPLIANCES AND DIRECT VENT HEATERS APPLICATION These instructions apply to the Simpson Dura-Vent 5"x 8" Direct Vent System. This venting
More informationFLANGED CORR/GUARD CORR/GUARD INSTALLATION INSTRUCTIONS
CORR/GUARD INSTALLATION INSTRUCTIONS This symbol on the nameplate means this product is listed by Underwriters Laboratories Inc. Tested to UL1738 / CAN / ULCS636-08 Listing No. MH26687 Testing No. 11EN
More informationTechnical and Dimensional Data. Saf-T Vent SC Plus
Technical and Dimensional Data Saf-T Vent S Plus 3"/5" & 4"/7" oncentric Reduced learance Double Wall for Special Gas Vent and/or Sealed ombustion Systems lso For Venting Listed Gas or Oil Fired ppliances
More informationCorr/Guard PRESSURE RATED VENTING SYSTEM IMPORTANT: DO NOT INSTALL WITHOUT FIRST READING THESE INSTRUCTIONS VERY CAREFULLY.
CORR/GUARD INSTALLATION INSTRUCTIONS This symbol on the nameplate means this product is listed by Underwriters Laboratories Inc. Tested to UL1738 / CAN / ULCS636-1995 Listing No. MH26687 Testing No. 11EN
More informationANY EVERY ONE ONE No matter what the venting application, from gas fired to oil to all fuel heating equipment, Z-FLEX is your one-stop solution.
NY EVERY ONE ONE No matter what the venting application, from gas fired to oil to all fuel heating equipment, Z-FLEX is your one-stop solution. Specialists in Flexible Z-FLEX has been providing flexible
More informationMitchell Metal Products, Inc.
Mitchell Metal Products, Inc. Mitchell Metal Products Kosciusko, Mississippi Established 1924 H i g h w a y 1 2 E P. O. B o x 7 8 9 K o s c i u s k o, M S 3 9 0 9 0 O f f i c e : 6 6 2-2 8 9-7 11 0 o r
More informationAll-fuel, double-wall chimney system. UL 103 HT, UL 103, and ULC S604.
DuraTech ll-fuel, double-wall chimney system. UL 103 HT, UL 103, and UL S60. DuraTech ll-fuel himney Typical Installations For 5-2 DuraTech *updated typicals* 6 1 19 8 16 1 19 5 1 8 1 6 2 Installation
More informationThe intelligent alternative for flue gas venting systems
The intelligent alternative for flue gas venting systems FIRST LISTED InnoFlue is the first polymeric vent system tested and listed to ULC-S636 and UL-1738 in North America Intelligent for a good reason
More informationVertical Termination Part No: 3CGRVT 16 7/8" 18 Vent Pipe Extension Part No: 3CG18 9 7/8" Wall Hanger Part No: 3CGWH 7 7/8" 7 3/8"
Corr/Guard Direct Vent Water Heater Vent/Air Intake System Installation and service must be performed by a qualified installer, service agency or the gas supplier. Installation must meet all state and
More informationBDM Direct Vent systems are for use with direct vent gas fired appliances.
INSTALLATION INSTRUCTIONS Pro-Form DIRECT VENT SYSTEM Tested to ANSI Z21.88-2009 /CSA 2.33-2009 REPORT # 369-P-02b-6.5 Read through all venting and appliance instructions before beginning your installation.
More informationEXCEL. ULTRABlack THE MOST DURABLE, EASIEST TO INSTALL RESIDENTIAL CHIMNEY SYSTEM YOU CAN BUY NEVER EVER BUY ANOTHER STOVE PIPE
THE MOST DURABLE, EASIEST TO INSTALL RESIDENTIAL CHIMNEY SYSTEM YOU CAN BUY ULTRABlack NEVER EVER BUY ANOTHER STOVE PIPE Chimney To determine what parts you need for your woodstove installation, try the
More informationVENT SYSTEM COMPONENTS
Chimney Liner Kits Chimney Liners - All Fuel Chimney Liners - Gas Made from durable, corrosion-resistant type 316 stainless steel Designed to be used with wood, oil, coal and non-condensing gas-fired appliances
More informationSMALL DIAMETER CORR/GUARD & SLEEVED CORR/GUARD
CORR/GUARD INSTALLATION INSTRUCTIONS This symbol on the nameplate means this product is listed by Underwriters Laboratories Inc. Tested to UL1738 / CAN / ULCS636-08 Listing No. MH26687 Testing No. 11EN
More informationPelletVent Pro. Biofuel venting system. UL 641, ULC S609, and ULC/ORD C441.
PelletVent Pro iofuel venting system. UL 641, ULC S609, and ULC/ORD C441. Specifications Applications PelletVent Pro is a venting system designed for stoves and inserts that use wood pellets and oil fuel.
More informationINSTALLATION INSTRUCTIONS
ELIMINATOR 36 Wood Burning Fireplace Models: 36E Non-Circulating (Smooth Face) I36E Non-Circulating (Smooth Face) Fully Insulated INSTALLATION INSTRUCTIONS SAVE THIS BOOK This book is valuable. In addition
More informationSUBJECT: SELKIRK MODEL DT DIRECT VENT SYSTEM FOR PELLET & CORN FIRED APPLIANCES / TERMINATION CLEARANCES TO OPENINGS IN BUILDINGS
Selkirk LLC Selkirk LLC Research & Development State Route 93 North & Sutton Road P.O. Box 631 Logan, OH 43138 9/21/2006 TO: Our Valued Customers FROM: Glen Edgar Director R&D SUBJECT: SELKIRK MODEL DT
More informationPelletVent Pro. Biofuel venting system. UL 641, ULC S609, and ULC/ORD C441.
PelletVent Pro iofuel venting system. UL 641, ULC S609, and ULC/ORD C441. Specifications Applications PelletVent Pro is a venting system designed for stoves and inserts that use wood pellets and oil fuel.
More informationSUBMITTAL RECORD. ULC S636 - PolyPro. Single-Wall Double-Wall Concentric Flex
SUMITTL RECORD ULC S636 - PolyPro Polypropylene vent pipe for use with NSI Category II and IV gas-burning appliances, including high efficiency water heaters, condensing boilers and warm air furnaces.
More informationVP Pellet Pipe. For pellet burning stoves. FEATURES
CATALOG VP Pellet Pipe For pellet burning stoves. Selkirk gives you the safe, efficient, and cost-effective venting system that's engineered precisely for pellet burning stoves. FEATURES Available in 3"
More informationGas Stoves. C34-10 Direct Vent Gas Stove. Side wall E F. Back wall F E. Model C34-NG10 C34-LP10
Back wall Gas Stoves Model C34-NG10 C34-LP10 Fuel Type Natural Gas Propane Minimum Supply Pressure 5.0 W.C. (1.25 kpa) 12.0 W.C. (3.00 kpa) Manifold Pressure - High 3.8 W.C. (0.95 kpa) 11 W.C. (2.74 kpa)
More informationFasNSeal 80/90 FasNSeal & FasNSeal W2 FasNSeal Flex
FasNSeal 80/90 FasNSeal & FasNSeal W FasNSeal Flex FSNSEL 80/90 hange to High Efficiency? Utilize Your Existing ommon Vent! FasNSeal 80/90 ap LISTINGS Storm ollar Flashing DuraVent s FNS 80/90 ombination
More informationPelletVent Pro horizontal Kit. PelletVent Pro. PelletVent Pro Vertical Kit - Cathedral. PelletVent Pro Pellet Chimney
PelletVent Pro horizontal Kit Kit includes: Round horizontal Cap, Wall Thimble, and Appliance Adapter. Pipe lengths not included. 4 Kit includes a 3-4 Appliance Adapter/Increaser, painted black. 3 3PVP-KHA
More informationType B Gas Vent. Installation Instructions
Installation Instructions Round and Oval Type B GasVent Systems for use with natural as or liquid propane category I and draft hood equipped appliances and appliances listed to use Type B Gas Vent. Type
More informationTwin wall Air Gap Insulated Zalutite & Aluminium Commercial Gas Vent Chimney System
Q Twin wall ir Gap Insulated Zalutite & luminium ommercial Gas Vent himney System Designed for Individual and Modular Natural Draught Gravity Flow himney pplications PRODUT INFORMTION INTRODUTION Q is
More informationGas Stoves. H15-10 Direct Vent Gas Stove. Model H15-NG10 H15-LP10. Approved Venting Systems
H15-10 Direct Vent Gas Stove Model H15-NG10 H15-LP10 Fuel Type Natural Gas Propane Minimum Supply Pressure 5.0 W.C. (1.25 kpa) 12.0 W.C. (3.00 kpa) Manifold Pressure - High 3.8 W.C. (0.95 kpa) 11 W.C.
More informationAdvanced Venting Systems
Advanced Venting Systems 1 Z-Vent Special Gas Vent 3 Flexible Vent Connector Systems 5 Aluminium Chimney Liner System 7 Stainless Steel Chimney Liner System 9 Oval Liner System / Advancing the Industry
More informationTYPE L VENT / VENT SYSTEM FOR PELLET BURNING APPLIANCES
INSTALLATION INSTRUCTIONS & MAINTENANCE GUIDE TYPE L VENT / VENT SYSTEM FOR PELLET BURNING APPLIANCES LISTED TO ULC-S609 & UL641 A MAJOR CAUSE OF VENT RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES
More informationVenting System For Pellet and Corn Stoves. PelletVent Pro. C o m p l e t e V e n t i n g S o l u t i o n s f o r t h e H e a r t h I n d u s t r y
Venting System For Pellet and Corn Stoves PelletVent Pro C o m p l e t e V e n t i n g S o l u t i o n s f o r t h e H e a r t h I n d u s t r y ii PelletVent Pro For Stoves Burning Pellets & Corn Simpson
More informationEasy to assemble. Silicone gasket sealed. Laser-welded seams. Smooth joint connections. 360 Lock-Tab secure rotation
Easy to assemble Silicone gasket sealed Laser-welded seams Smooth joint connections 360 Lock-Tab secure rotation Evenly spaced inner and outer pipes Continuous column of air insulation Ultimate Pellet
More informationZ-VENT MODEL SVE SERIES III INSTALLATION AND MAINTENANCE INSTRUCTIONS
Z-VENT MODEL SVE SERIES III INSTALLATION AND MAINTENANCE INSTRUCTIONS 3 & 4 SPECIAL STAINLESS STEEL VENTING SYSTEM FOR GAS BURNING APPLIANCES CATEGORY I, II, III, & IV TESTED AND LISTED BY UNDERWRITERS
More informationULC S636 System. PolyPro. PolyPro Flex. Terminations
PolyPro Polypropylene venting products for high-efficiency condensing appliance installations. Chloride free, environmentally safe. Listed to ULC-S636. Specifications pplications PolyPro is a polypropylene
More informationSL-VENT (oil and gas vent) For use with oil or gas fired appliances. Listed to ULC-609 and UL-641. Available in 5, 6, 7 and 8 I. D.
Typical Installations 0 8 9 Vertical Installation. Vertical Termination ap. Storm ollar. Flashing. Roof Support. Length. ttic Radiation Shield. Firestop 8. ecorative lack Plate 9. Length (lack) 0. Insulation
More informationAL29-4C (UNS S44735) Direct Vent System for Category II, III & IV Heating Equipment 3 through 16
L29- (UNS S7) Direct Vent System for ategory II, III & IV Heating Equipment through Set the standard as the first vent system with a built-in gasket and locking band, designed for high efficiency gas heaters
More informationInstallation & Maintenance Instructions
Installation & Maintenance Instructions Listed & Tested to UL641, ULC-S609, ULC/ORD C441 AMERIVENT Model PVP Pellet Pipe Plus Vent Connector for Pellet-Fuel Appliances and Other Low-Temperature Applications
More informationInstallation Instructions. Venting System for Pellet, Corn, Oil, and Biofuel appliances. PelletVent Pro
Installation Instructions Venting System for Pellet, Corn, Oil, and Biofuel appliances. PelletVent Pro A MAJOR CAUSE OF VENT RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES) TO COMBUSTIBLE
More informationPelletVent Pro. Installation Instructions. C o m p l e t e V e n t i n g S o l u t i o n s f o r t h e H e a r t h I n d u s t r y
Installation Instructions Venting System For Pellet and Corn Stoves PelletVent Pro C o m p l e t e V e n t i n g S o l u t i o n s f o r t h e H e a r t h I n d u s t r y A MAJOR CAUSE OF VENT RELATED
More informationH35 Direct Vent Gas Stove. 17,500 BTU/h (5.13 kw) 34,000 BTU/h (9.97 kw) 15,000 BTU/h (4.39 kw) 28,500 BTU/h (8.35 kw)
H35 Direct Vent Gas Stove Model H35-NG10 H35-LP10 Fuel Type Natural Gas Propane Minimum Supply Pressure 5.0 W.C. (1.25 kpa) 12.0 W.C. (3.00 kpa) Manifold Pressure - High 3.8 W.C. (0.94 kpa) 11 W.C. (2.74
More informationH35 Direct Vent Gas Stove. 17,500 BTU/h (5.13 kw) 34,000 BTU/h (9.97 kw) 15,000 BTU/h (4.39 kw) 28,500 BTU/h (8.35 kw)
H35 Direct Vent Gas Stove Model H35-NG10 H35-LP10 Fuel Type Natural Gas Propane Minimum Supply Pressure 5.0 W.C. (1.25 kpa) 12.0 W.C. (3.00 kpa) Manifold Pressure - High 3.8 W.C. (0.94 kpa) 11 W.C. (2.74
More informationVenting. Vent Material. Approved Venting Accessories Simpson Dura-Vent DV unless otherwise specified. Wall Thickness
Venting Vent Material This unit is approved for installation using 4 x 6-5/8 in co-axial direct vent pipe and accessories manufactured by Simpson Dura-Vent. Follow the installation instructions supplied
More informationP P Gas Fireplace. P See Thru
P121-10 - P131-10 Gas Fireplace Model P121/P131-NG10 P121/P131-LP10 Fuel Type Natural Gas Propane Minimum Supply Pressure 5 W.C. (1.25 kpa) 12 W.C. (3.00 kpa) Manifold Pressure - High 3.8 W.C. (0.95 kpa)
More informationPolyPro: For Venting Condensing Appliances Environmentally Safe Alternative Lower Over-All Cost Than PVC Engineered Terminations Fast, Easy To Install
PolyPro : For Venting Condensing Appliances Environmentally Safe Alternative Lower Over-All Cost Than PVC Engineered Terminations Fast, Easy To Install Being Green, Being Responsible. DuraVent looks for
More informationShasta Vent Inc All-Fuel HT Chimney Installation Instructions
Shasta Vent Inc All-Fuel HT Chimney Installation Instructions August 2015 v1.02 A MAJOR CAUSE OF CHIMNEY RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES) TO COMBUSTIBLE MATERIALS.
More information2012 INTERNATIONAL FUEL GAS CODE VENTS
2012 INTERNATIONAL FUEL GAS CODE SECTION 502 (IFGC) VENTS 502.1 General. All vents, except as provided in Section 503.7, shall be listed and labeled. Type B and BW vents shall be tested in accordance with
More informationINSTALLATION AND MAINTENANCE INSTRUCTIONS. 1700ºF Air-Cooled and Insulated ECO-STEEL Chimney Size 13
Chimney Solutions INSTALLATION AND MAINTENANCE INSTRUCTIONS 1700ºF Air-Cooled and Insulated ECO-STEEL Chimney Size 13 Listing No. MH8251 Tested to UL103/ULC-S604 A MAJOR CAUSE OF RELATED FIRES IS FAILURE
More informationInstallation Instructions. Venting System for Pellet, Corn, Oil, and Biofuel appliances. PelletVent Pro
Installation Instructions Venting System for Pellet, Corn, Oil, and Biofuel appliances. PelletVent Pro A MAJOR CAUSE OF VENT RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES) TO COMBUSTIBLE
More informationVenting Supplement. Direct Vent Through-Roof or Through-Unused-Chimney. Water Boiler Series 3 & 4
GOLD GV Water Boiler Series 3 & 4 Venting Supplement Direct Vent Through-Roof or Through-Unused-Chimney For use with Weil-McLain Through-Roof or Through- Unused-Chimney Termination Kit Kit part # 382-200-435
More informationINSTALLATION INSTRUCTIONS
42" WOODBURNING FIREBOX Model C42EC2 Circulating (Louvered) INSTALLATION INSTRUCTIONS SAVE THIS BOOK This book is valuable. In addition to instructing you on how to install and maintain your appliance,
More informationTwin Wall Installation Instructions And Maintenance Guide
Twin Wall Installation Instructions And Maintenance Guide Please read all instructions before beginning your installation. Failure to install this system in accordance with these instructions will invalidate
More informationINSTALLATION INSTRUCTIONS FOR SV4.5RR4 PIPE REDUCER AND ALL ASSOCIATED SV4
1508 Elm Hill Pike, Suite 108 Nashville, TN 37210 P Rev. C 06/2014 INSTALLATION INSTRUCTIONS FOR PIPE REDUCER AND ALL ASSOCIATED SV4 (4") SECURE VENT/DIRECT VENT COMPONENTS INCLUDING SV4CGV-1 VERTICAL
More informationCity Series CV40E Gas Fireplace
Model CV40E-NG CV40E-LP Fuel Type Natural Gas Propane Minimum Supply Pressure 5 W.C. (1.25 kpa) 11 W.C. (2.73 kpa) Manifold Pressure - High 3.8 W.C. (0.94 kpa) 10.5 W.C. (2.62 kpa) Manifold Pressure -
More informationThe Monterey (PENNINSULA) MODEL PN36 3-SIDED, WOOD-BURNING FIREPLACE
The Monterey (PENNINSULA) MODEL PN36 3-SIDED, WOOD-BURNING FIREPLACE INSTALLATION AND OPERATING INSTRUCTIONS SAVE THIS BOOK This book is valuable. In addition to instructing you on how to install and maintain
More informationDT-M Direct-Temp for Multi Fuel L-Vent / Vent System for Pellet, Corn and other Bio-Fuel Burning Appliances
Installation Instructions & Owners Maintenance Guide DT-M Direct-Temp for Multi Fuel L-Vent / Vent System for Pellet, Corn and other Bio-Fuel Burning Appliances Introduction Direct-Temp for Multi-Fuel
More informationCity Series CB40E Gas Fireplace
Model CB40E-N CB40E-LP Fuel Type Natural as Propane Minimum Supply Pressure 5 W.C. (1.25 kpa) 11 W.C. (2.73 kpa) Manifold Pressure - igh 3.8 W.C. (0.94 kpa) 10.5 W.C. (2.62 kpa) Manifold Pressure - Low
More informationVentis Direct Vent. Installation Instructions
entis Direct ent Installation Instructions A MAJOR CAUSE OF CHIMNEY RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES), TO COMBUSTIBLE MATERIALS. IT IS OF THE UTMOST IMPRORTANCE THAT
More informationDirect Exhaust Venting Kit Instructions
CONDENSING GAS BOILER 220/299/300/399 Direct Exhaust Venting Kit Instructions Evergreen 220/299/300/399 Kit part number 383-500-769 STOP! Read before proceeding Hazard definitions The following defined
More informationFasNSeal 80/90 FasNSeal & FasNSeal W2 FasNSeal Flex
FasNSeal 80/90 FasNSeal & FasNSeal W FasNSeal Flex FSNSEL 80/90 hange to High Efficiency? Utilize Your Existing ommon Vent! FasNSeal 80/90 ap LISTINGS Storm ollar Flashing DuraVent s FNS 80/90 ombination
More information2220 SE Ninth Avenue 2113 Delta Waters Road Portland OR Medford OR SKU Descrpition List
3" Pipe and Fittings GV36 3"x6" B VENT PIPE $12.44 GV312 3"x12" B VENT PIPE $11.13 GV318 3"x18" B VENT PIPE $14.40 GV324 3"x24" B VENT PIPE $17.89 GV336 3"x36" B VENT PIPE $23.09 GV348 3"x48" B VENT PIPE
More informationInstallation and Maintenance Instructions
Installation and Maintenance Instructions Saf-T Vent Model EZ Seal Single Wall AL 29-4C Stainless Steel Gas Vent Connector Chimney Liner & Special Gas Vent (USA) / Type BH Vent Class I/II (Canada) For
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS FACTORY BUILT CHIMNEY CONNECTOR A MAJOR CAUSE OF CHIMNEY CONNECTOR RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES) TO COMBUSTIBLE MATERIALS. IT IS OF THE
More informationSTORM COLLAR 3/4" AIR SPACE BACK AND SIDES 31 5 / / /16 LOUVERS ON MODEL 3601 ONLY AIR KIT K/O GAS LINE K/O OUTSIDE AIR (LEFT SIDE ONLY)
INSTALLATION INSTRUCTIONS BARON WOODBURNING FIREBOX V3600 Non-Circulating V3601 Circulating SAVE THIS BOOK This book is valuable. In addition to instructing you on how to install and maintain your appliance,
More informationInstallation and Maintenance Instructions
Installation and Maintenance Instructions Saf-T Vent Model EZ Seal and Model GC Single Wall AL 29-4C Stainless Steel Gas Vent Connector Chimney Liner & Special Gas Vent (USA) / Type BH Vent Class I/II
More informationInstallation and Maintenance Instructions
Commercial & Industrial Positive Pressure or Condensing AL 29-4C Stainless Steel High Challenge Special Gas Vent Also for Natural Draft Appliances 3",4",5",6",7",8",9",10" and 12" Diameter Special Gas
More informationNovaVent. Dimensional Data
NovaVent Dimensional Data NovaVent The new vent system designed and engineered for today s competitive sales environment. NovaVent NovaVent is designed and engineered to meet the requirements of gas-fired
More informationAqua Balance. Direct Exhaust Venting Kit Instructions
Aqua Balance WMB-155H and WMB-155C Wall Mount Gas-Fired Heating Only Boiler & Combination Boiler Heating and Domestic Hot Water Direct Exhaust Venting Kit Instructions AquaBalance TM WMB-155H & WMB-155C
More informationINSTALLATION OF VENTING SYSTEM COMPONENTS WARNING
INSTALLATION OF VENTING SYSTEM COMPONENTS WARNING When installing the EVERHOT IGI model series direct vent water heaters, use only EVERHOT vent/air intake system kits and components. Installation and service
More informationVent Kit for Condensing Tankless Gas Water Heater
Installation Manual NORITZ AMERICA CORPORATION Vent Kit for Condensing Tankless Gas Water Heater Model: EZ2FVK-1 (Flex Vent 2" Kit 25 feet) Potential dangers from accidents during installation and use
More informationThe Next Generation of Greenfield Connectors. Our flex System is Your Solution for Electrical Runs
1/2 to 2 Solid Steel or luminum The Next Generation of Greenfield onnectors SPE-flex Our flex System is Your Solution for Electrical Runs connectors Since 1946 Straight onnectors for Enclosures or Use
More informationSEPARATED COMBUSTION. General WARNING
Form I-UD-V-SC (09-17) Obsoletes Form I-UD-V-SC (Version 05-17) APPLIES TO: Venting Requirements for Model UDAS and Model UDBS and Instructions for Combustion Air Inlet / Vent Terminal Options CC6 and
More informationANY EVERY ONE ONE No matter what the venting application, from gas fired to oil to all fuel heating equipment, Z-FLEX is your one-stop solution.
ANY EVERY ONE ONE No matter what the venting application, from gas fired to oil to all fuel heating equipment, Z-FLEX is your one-stop solution. Specialists in Flexible Z-FLEX has been providing flexible
More informationINS A T LL T A ION, OPER T A ING AND SERVICE INSTRUCTIONS FOR FREEDOM CONDENSING HIGH EFFICIENCY DIRECT VENT GAS - FIRED HOT
INSTALLATION, OPERATING AND SERVICE INSTRUCTIONS FOR FREEDOM CONDENSING HIGH EFFICIENCY DIRECT VENT GAS - FIRED HOT WATER BOILER Warning: Improper installation, adjustment, alteration, service or maintenance
More information200i. Vent/air manual. Installation instructions for vent and air piping. Also read and follow: 200i Boiler manual 200i Control manual
M2i-VAM-2 Cast iron condensing boiler 200i Vent/air manual Installation instructions for vent and air piping Also read and follow: 200i Boiler manual 200i Control manual This manual is intended only for
More informationInstallation and Maintenance Instructions
Installation and Maintenance Instructions Saf-T Vent Model EZ Seal and Model GC Single Wall AL 29-4C Stainless Steel Gas Vent Connector Chimney Liner & Special Gas Vent (USA) / Type BH Vent Class I/II
More informationManual. Owners & Installation. Zero Clearance Room Sealed Gas Fireplace PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE
Owners & Installation Manual LISTINGS AND CODE APPROVALS These gas appliances have been tested in accordance with AG 103, NZS 5262 and have been certified by the Australian Gas Association for installation
More informationINSTALLATION AND OPERATING INSTRUCTIONS
PENINSULA MODEL VPN36 3-SIDED, WOODBURNING FIREBOX INSTALLATION AND OPERATING INSTRUCTIONS SAVE THIS BOOK This book is valuable. In addition to instructing you on how to install and maintain your appliance,
More informationPOWER VENT. Standard Power Vent, Fan Type Unit Heaters: Standard Power Vent, Blower Type Unit Heaters: General WARNING WARNING. Model UDAP & Model APD
General APPLIES TO: Standard Power Vent, Fan Type Unit Heaters: Model UDAP & Model APD Standard Power Vent, Blower Type Unit Heaters: Model UDBP Form I-UD&APD Series-V-PV (05-17) Obsoletes I-UD&APD Series-V-PV
More informationMODEL CF CEILING SUPPORTED CHIMNEY
Manufactured by Selkirk Canada Corp. - Hamilton, Ontario Installation Instructions for MODEL CF CEILING SUPPORTED CHIMNEY Round Top Storm Collar Flashing Attic Insulation Shield/Firestop Spacer Intermediate
More informationThe Next Generation of Greenfield Connectors. Our flex System is Your Solution for Electrical Runs
1/2 to 4 Solid Steel or luminum The Next Generation of Greenfield onnectors SPE-flex Our flex System is Your Solution for Electrical Runs connectors GURNTEED to Save Time On Every onnection You Make. Patent
More informationInstallation and Maintenance Instructions
Installation and Maintenance Instructions Saf-T Vent Model EZ Seal Single Wall AL 29-4C Stainless Steel Gas Vent Connector Chimney Liner & Special Gas Vent (USA) / Type BH Vent Class I/II (Canada) For
More informationSaf-T Vent SC Plus/SC 316
Installation and Maintenance Instructions Saf-T Vent SC Plus/SC 316 Double Wall One Inch Air Space Special Gas Vent For Venting Residential and Light Commercial Appliances Category I,II,III,IV Appliances
More informationEUTECTIC EC-10DV Series
EUTECTIC EC-10DV Series DIRECT VENT OIL-FIRED WATER BOILER/NO. 2 OIL VENTING INSTALLATION INSTRUCTIONS CONTENTS..........................................PAGE Basic Guidelines..........................................1
More informationINNOVATIVE AIR DISTRIBUTION PRODUCTS
INNOVATIVE AIR DISTRIBUTION PRODUCTS 2018 PRODUCT CATALOG SUPERIOR QUALITY PLASTIC TIME SAVING TECHNOLOGY OUR COMPANY HaVACo Technologies, Inc. (located in Erie, Pennsylvania) designs and manufactures
More informationInstallation Instructions. PolyPro Single-Wall Gas Vent System for Category II & IV Gas-Burning Appliances. PolyPro
Installation Instructions PolyPro Single-Wall Gas Vent System for Category II & IV Gas-Burning Appliances PolyPro A MAJOR CAUSE OF VENT RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES)
More informationMascot. Gas-Fired Residential and Commercial Wall-Mounted Boiler. Easy Installation, 96% Efficiency, Fully Condensing
Mascot Gas-Fired Residential and Commercial Wall-Mounted Boiler Easy Installation, 96% Efficiency, Fully Condensing Mascot is a high-efficiency, wall-mounted boiler available in three BTU sizes 126, 167,
More informationINSTALLATION INSTRUCTIONS AH12 WALL MOUNT HOOD
Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS AH12 WALL MOUNT HOOD Read All Instructions Thoroughly Before Beginning Installation WARNING
More information36" Open Corner Circulating (Louvered)
36" Open Corner Circulating (Louvered) Wood Burning fireplace OWNER S OPERATION AND INSTALLATION MANUAL CPFS US ICC-ES #ESR-2542 Open Corner Wood Burning Fireplace (V)36R(S) Right Side Opening; (V)I36R(S)
More information