FasNSeal 80/90 FasNSeal & FasNSeal W2 FasNSeal Flex

Size: px
Start display at page:

Download "FasNSeal 80/90 FasNSeal & FasNSeal W2 FasNSeal Flex"

Transcription

1 FasNSeal 80/90 FasNSeal & FasNSeal W FasNSeal Flex

2 FSNSEL 80/90 hange to High Efficiency? Utilize Your Existing ommon Vent! FasNSeal 80/90 ap LISTINGS Storm ollar Flashing DuraVent s FNS 80/90 ombination at I and at IV gas vent system is designed and UL listed for use with approved DuraVents special gas vent components only! Listed to applicable portions of UL S636/UL1777, and UL441. FasNSeal Flex ttic Insulation Shield Square Firestop Support Double Wall Wye ME R -R E DY L OG OT Y P E UL M R K F OR N D ND T HE U.S. T hese Marks are registered by Underwriters L aboratories Inc. FasNSeal Flex to PolyPro dapter Firestop 45 /60 djustable Elbow PolyPro Pipe Length Draft Hood onnector Elbow Locking ands dapter onnector ppliance dapter LISTED MH6357 FasNSeal 80/90 Feature enefit vailable in 5-8 Vent Diameters. Fits most residential common vent systems. pproved for installation in other manufacturers Vent, with listed at I adapters available. Unmatched installation flexibility. T he minimum height of the registered trademark symbol shall be 3/64 of an inch. When the overall diameter of the UL Mark is less than 3/8 of an inch, the trademark symbol may be omitted if it is not legible to the naked eye. orrosion resistant SS steel flex liner. Superior flow performance allowing longer runs before upsizing, and superior condensate management. Withstands high temperatures inside at I vent. Dual path (at I / at IV) termination cap. Warm at I exhaust helps reduce icing on condensing at IV exhaust. Engineered sizing guidance for combined system. ddition of SS flex to orphaned common vent system helps reduce oversizing issues, enhances draft of remaining at I appliance. SS flexthas smooth inner wall. he font for all letter forms is Helvetica ondensed lack, except for the trademark symbol, which is Helvetica ondensed Medium. No other fonts are acceptable M/11/97 ompatible with portfolio of DuraVent special gas vent products, including Utilize exiting appliance adapters, current appliance approvals. PolyPro and FNS. Eliminates issues with Horizontal terminations, including wind effects, Vertical Termination. icing, code issues, etc. No additional building penetrations required, no disturbing finished ombined at I / at IV vent system takes up no additional space. internal spaces, etc. UL tested, listed engineered system. Industry first (and only) listing of it s kind.

3 1 STRIGHT UP INSTLLTION Description Order # Stock # 5 6 WYE INSTLLTION Vent Firestop 3x -Vent Firestop FSFS-GVPP x -Vent Firestop FSFS-GVPP x3 -Vent Firestop FSFS-GVPP x -Vent Firestop FSFS-GVPP x3 -Vent Firestop FSFS-GVPP x4 -Vent Firestop FSFS-GVPP x -Vent Firestop FSFS-GVPP x3 -Vent Firestop FSFS-GVPP x4 -Vent Firestop FSFS-GVPP x5 -Vent Firestop FSFS-GVPP Universal Female dapter 3 Female dapter 3GVF Female dapter 4GVF Female dapter 5GVF Female dapter 6GVF Female dapter 7GVF Female dapter 8GVF Double Wall Wye 45º ranch 4 x4 x3 Double Wall Wye 4GVY x4 x4 Double Wall Wye 4GVY x3 x4 Double Wall Wye 4GVY x3 x4 Double Wall Wye 5GVY x4 x4 Double Wall Wye 5GVY x4 x5 Double Wall Wye 5GVY x3 x4 Double Wall Wye 6GVY x4 x3 Double Wall Wye 6GVY x4 x4 Double Wall Wye 6GVY x4 x5 Double Wall Wye 6GVY x3 x5 Double Wall Wye 6GVY x4 x6 Double Wall Wye 6GVY x3 x5 Double Wall Wye 7GVY nnular Space - Effective Remaining Vent Diameter 0 at IV Liner 03 at IV Liner 04 at IV Liner 05 at IV Liner 5 Vent 4 3 N/ N/ 6 Vent N/ 7 Vent Vent Special Gas Vent FasNSeal Description Order # Stock # Vertical Terminations 05"x" ombo ap FS "x3" ombo ap FS "x" ombo ap FS "x3" ombo ap FS "x4" ombo ap FS "x" ombo ap FS "x3" ombo ap FS "x4" ombo ap FS "x" ombo ap FS "x3" ombo ap FS "x4" ombo ap FS "x5" ombo ap FS "x5" ombo ap FS FasNSeal Flex 0"x0' FasNSeal Flex FSFLEX "x5' FasNSeal Flex FSFLEX "x30' FasNSeal Flex FSFLEX "x35' FasNSeal Flex FSFLEX "x50' FasNSeal Flex FSFLEX "x00' FasNSeal Flex FSFLEX "x0' FasNSeal Flex FSFLEX " ustom FNS Flex FSFLEX-XX x 0 FasNSeal Flex 3FSFLEX x 5 FasNSeal Flex 3FSFLEX x 30 FasNSeal Flex 3FSFLEX x 35 FasNSeal Flex 3FSFLEX x 00 FasNSeal Flex 3FSFLEX x 0 FasNSeal Flex 4FSFLEX x 5 FasNSeal Flex 4FSFLEX x 30 FasNSeal Flex 4FSFLEX x 35 FasNSeal Flex 4FSFLEX x 00 FasNSeal Flex 4FSFLEX x 0 FasNSeal Flex 5FSFLEX x 5 FasNSeal Flex 5FSFLEX x 30 FasNSeal Flex 5FSFLEX x 35 FasNSeal Flex 5FSFLEX x 15 FasNSeal Flex 5FSFLEX PP to FNS Flex dapter " PP to FNS Flex dapter FSSMM-PP " PP to FNS Flex dapter FSSMM-PP " PP to FNS Flex dapter FSSMM-PP " PP to FNS Flex dapter FSSMM-PP-5 DuraVent

4 FasNSeal Special Gas Vent Specifications pplications FasNSeal and FasNSeal Flex is for use with natural gas or propane ategories II, III and IV appliances or anada s Type H Gas Vent Systems, having a maximum rated operating temperature of 480 F and a maximum positive pressure of 15 (FasNSeal Flex 6") water column. FasNSeal can be used on a wide range of applications, including: high efficiency gas boilers, furnaces, booster heaters, pool heaters, water heaters, unit heaters, or tankless water heaters. FasNSeal W is ideal for use on commercial applications such as: office buildings, medical facilities, condos, or multiple unit apartment complexes where there is the need for low clearances to combustibles. In residential applications, FasNSeal W is the perfect solution for running between floor joists or in walls. Materials and onstruction FasNSeal 3 7 : L : L : L FasNSeal Flex Single strip double layer super-ferritic stainless steel (totalling.010 ). FasNSeal W 3 6 : L9-4 stainless steel.016 inner wall, stainless steel.016 outer wall. 7 : L9-4 stainless steel.016 inner wall, stainless steel.04 outer wall. 8 1 : L9-4 stainless steel.019 inner wall, stainless steel.04 outer wall : L9-4 stainless steel.04 inner wall, stainless steel.04 outer wall. UL 1738 and UL S636 Systems FasNSeal & FasNSeal W ll FasNSeal (single-wall) and FasNSeal W (double-wall) vent lengths and components feature patented built-in mechanical locking band and triple-lipped directional gaskets. ll pipes and components are engineered with smooth clean welds located 90 from mechanical locking bands. This construction feature allows for ease of installation. The ½ air space between the inner and outer wall on FasNSeal W helps to reduce the clearance to combustibles in addition to creating a heat shield for additional safety. ll FasNSeal components which come in contact with exhaust gases and condensates are now silicone free. This important design and manufacturing feature greatly reduces the chances of system breakdown and failure. The main problems with silicone are there are too many adhesion factors which are very difficult to control and the process of binding similar materials with an epoxy, which can weaken the bond over time. Welded seams ensure a leak-free product that is meant to last. FasNSeal Flex Made from super-ferritic stainless steel. orrosion resistant. Manufactured with a sure-seal locking seam for superior strength and flexibility. The smooth inner-wall provides for no output reduction, allowing for full appliance efficiency, ease of cleaning and regular maintenance. The smooth inner wall optimizes gas flow, minimizes back pressure, and facilitates condensate management. Flexible chimney liner is listed to UL 1738 standard. Diameters FasNSeal (single- and double-wall) 3-16 FasNSeal Flex 3-1 Listings FasNSeal (single- and double-wall) ETL Listed to UL 1738 and UL S636. FasNSeal Flex UL Listed to UL 1738 and UL 1777 and UL S DuraVent

5 Special Gas Vent FasNSeal Typical Installations Installation Key 1 Rain ap 9 Universal ondensate Drain Storm ollar 10 ppliance dapter 3 Variable Pitch Roof Flashing 11 Top Plate* 4 Vent Length 1 Female Flex dapter 5 djustable Vent Length 13 FasNSeal Flex 6 Firestop/Flat Flashing 14 Male Flex dapter 7 Horizontal Drip Tee 15 Standard Tee 8 Elbow Refer to our Typical Venting Installation drawings to select the appropriate component parts for your installation Multi-Story FasNSeal Offset FasNSeal Elbow Vent Length Termination/Wall Thimble with Volumetric Damper Universal ondensate Drain 13 Tankless H0 ppliance dapter Offset with Tee FasNSeal Flex & FasNSeal DuraVent 75

6 D 3. USE NON-OMUSTILE HNGER EVERY SIX (6) FEET OF HORIZONTL RUN. 4. USE FIRE-RTED FIRESTOPS WHEN PENETRTING FIRE-RTED WLLS ND/OR EILINGS. 5. REFER TO THE FSNSEL INSTLLTION INSTRUTIONS FOR DDITIONL REQUIREMENTS. NOTE: Every effort has been made to ssure the accuracy of this information. Dura-Vent cannot guarantee ccuracy and will not be held liable for Errors or omissions. 4 NOTES: 1. LL WORKMNSHIP MUST MEET ND/OR EXEED LL JURISDITIONL REQUIREMENTS.. INSTLL WLL RKET EVERY TWELVE (1) FEET OF VERTIL RUN X X 6 10 X X X ITEM REVISION HISTORY ZONE REV DESRIPTION DTE PPROVED DRWN W. YOUNG 9//010 HEKED Q MFG PPROVED QTY USTOMER # PRTS LIST PRT NUMER DESRIPTION FS-E W FS-SWDW W-VL8-L W W-VL W W W-VL8-L W W-VL8-L W W FS-DWSW FSS FSL9 SIZE THIRD NGLE PROJETION DWG NO 1 SHEET 1 OF 1 USTOM 6 in. length 8 in. length 10 in. length NOTIE: THIS DOUMENT ONTINS PROPRIETRY INFORMTION ND IT SHLL NOT E USED, REPRODUED, OR ITS ONTENTS DISLOSED, IN WHOLE OR IN PRT, WITHOUT THE EXPRESS WRITTEN ONSENT OF PROTEH SYSTEMS DIVISION OF M & G DUR-VENT OMPNY, IN. REV D FasNSeal Special Gas Vent ommercial pplications ommercial projects may require custom parts and unique system designs. DuraVent offers complete project assistance: oilers are: erco MK..0 (3X) M & G Engineering Services: Personalized system design services offer comprehensive D submittal drawing and complete bills of materials. ustom Parts: If your project requires innovative solutions, contact DuraVent for custom parts that meet your specific project needs. FasNSeal W: FasNSeal W is the ideal choice for commercial applications where there is a need for low clearances to combustibles. Up to 16 Vent Diameters: Many commercial applications require large diameter systems due to the units size and output. Large diameters are available in single and double wall, featuring FasNSeal s triple lipped directional gaskets and built-in locking band which provides a safe and convenient installation. learances hart FasNSeal Rated Operating Temperatures Enclosed Unenclosed Horizontal Vertical Horizontal Vertical F \ 90 0" 0" (anada Only) 300 F / 149 Sides: Top: F / 49 ottom: F / 90 0" 0" (anada Only) 300 F \ Noncombustible Enclosure 480 F \ FasNSeal W Rated Operating Temperatures Enclosed Unenclosed Horizontal Vertical Horizontal Vertical 194 F (anada Only) 0" 0" 0" 0" F F 6" F 6" F (anada Only) 0" 0" 0" 0" F F 6" F 6" Rated Operating Temperature of 300 F = Max Flue Gas Temperature of 375 F Rated Operating Temperature of 480 F = Max Flue Gas Temperature of 550 F 76 DuraVent

7 Special Gas Vent FasNSeal FasNSeal - Single-Wall Vent Length Use to vent category II, III and IV appliances. SIZE ORDER # STOK # SIZE ORDER # STOK # 3 FSVL FSVL FSVL FSVL FSVL FSVL FSVL FSVL FSVL FSVL FSVL FSVL FSVL FSVL FSVL FSVL FSVL FSVL " 18 6 FSVL FSVL FSVL FSVL FSVL FSVL FSVL FSVL FSVL FSVL FSVL FSVL FSVL FSVL FSVL FSVL FSVL FSVL FSVL FSVL FSVL FSVL FSVL FSVL FSVL FSVL FSVL FSVL FSVL FSVL FSVL FSVL FSVL FSVL FSVL FSVL FSVL DuraVent 77

8 FasNSeal Special Gas Vent djustable Vent Length Use to add length to straight length of FasNSeal pipe. dds 14 of length. Requires at least 4 overlap for a secure connection. vailable in ustom Lengths SIZE ORDER # STOK # SIZE ORDER # STOK # 3 FSVL " FSVL FSVL " FSVL FSVL FSVL FSVL FSVL FSVL FSVL FSVL djustable Vent Length Use to facilitate for the pitched required in horizontal runs SIZE ORDER # STOK # SIZE ORDER # STOK # 3" FSVL " FSVL " FSVL " FSVL " FSVL " FSVL " FSVL " FSVL " FSVL " FSVL " FSVL DuraVent

9 Special Gas Vent FasNSeal FasNSeal Flex Use to vent ategory II,III and IV gas burning appliances. Listed to UL an only be used in vertical or near vertical runs. ustom lengths are available for 3-1 diameters. Minimum length of 10 for custom orders. Maximum length of 50' for 3" - 9" diameter custom orders and 5' for 10" and 1" diameter custom orders. Must be ordered in 10' increments. Use with FasNSeal components only. SIZE Order # Stock # Order # Stock # Order # Stock # Order # Stock # 3 3FSFLEX FSFLEX FSFLEX FSFLEX FSFLEX FSFLEX FSFLEX FSFLEX FSFLEX FSFLEX FSFLEX FSFLEX FSFLEX FSFLEX FSFLEX FSFLEX FSFLEX FSFLEX FSFLEX FSFLEX FSFLEX FSFLEX FSFLEX FSFLEX SIZE Order # Stock # Order # Stock # Order # Stock # Order # Stock # FSFLEX FSFLEX FSFLEX FSFLEX FSFLEX SIZE USTOM USTOM SIZE ORDER # STOK # ORDER # STOK # 3" 3FSFLEX-XX " 8FSFLEX-XX " 4FSFLEX-XX " 9FSFLEX-XX " 5FSFLEX-XX " 10FSFLEX-XX FSFLEX-XX " 1FSFLEX-XX " 7FSFLEX-XX FasNSeal Flex Rain ap Terminates FS Flex with support. SIZE ORDER # STOK # SIZE ORDER # STOK # FSFLEXR ¾ 7" FSFLEXR ¾ 3 FSFLEXR " FSFLEXR FSFLEXR " FSFLEXR ¾ 5 FSFLEXR ½ 10 FSFLEXR FSFLEXR ½ 1 FSFLEXR DuraVent 79

10 FasNSeal Special Gas Vent FasNSeal Flex Top over Plates Supports FSFLEXR Terminations. SIZE ORDER # STOK # SIZE ORDER # STOK # FSFLEXTP ½ 16 7" FSFLEXTP " 3 FSFLEXTP " 8" FSFLEXTP " 4 FSFLEXTP " 9" FSFLEXTP " 5 FSFLEXTP " 10 FSFLEXTP " 18" 6 FSFLEXTP " 1 FSFLEXTP " FasNSeal Flex oupler Used to connect two () lengths of FasNSeal Flex together. SIZE ORDER # STOK # SIZE ORDER # STOK # FSFLEX " 3 8" 7" FSFLEX " 7 3 8" 3 FSFLEX " 3 ½" 8" FSFLEX " 8 3 8" 4 FSFLEX " 4 3 8" 9" FSFLEX " " 5 FSFLEX " 5 3 8" 10 FSFLEX " " 6 FSFLEX " 6 3 8" 1 FSFLEX " " Male Flex dapter Use to connect FasNSeal rigid Vent Pipe to FasNSeal Flex at base of masonry chimney or bottom termination. SIZE ORDER # STOK # 3 FSSMM FSSMM FSSMM FSSMM FSSMM SIZE ORDER # STOK # 8" FSSMM " FSSMM " FSSMM FSSMM PolyPro Rigid to FasNSeal Flex dapter Use to connect FasNSeal Flex to PolyPro rigid Vent Pipe at the bottom of the system. D D " 1.0 SIZE ORDER # STOK # D FSSMM-PP " 7 16" 5" " 3 FSSMM-PP " 3 ½" 6" 3" 4 FSSMM-PP " " 6" 3" 5 FSSMM-PP " " 6" 3" 6 FSSMM-PP " " 6" 3" 8 FSSMM-PP " " 7" 3" 3" - 8" 80 DuraVent

11 Special Gas Vent FasNSeal Female Flex dapter Use to connect FasNSeal Flex to FasNSeal rigid Vent Pipe at the top of the system. Ø Ø SIZE ORDER # STOK # SIZE ORDER # STOK # 3 FSSMF " FSSMF FSSMF " FSSMF FSSMF " FSSMF FSSMF FSSMF FSSMF Test Port Use to test for proper appliance operation without penetrating the vent wall. Easy access to perform flue gas analysis. More options available, see Universal dapter w/test Port in FasNSeal ppliance dapter section. 5⅞" SIZE ORDER # STOK # SIZE ORDER # STOK # 3 FSTP FSTP FSTP FSTP FSTP FSTP FSTP " FSTP " FSTP " FSTP FSTP Elbow Use to go from horizontal to vertical runs or vertical to horizontal runs. Use to turn vent 90. SIZE ORDER # STOK # 3 FSEL FSEL FSEL FSEL FSEL FSEL SIZE ORDER # STOK # 9" FSEL " FSEL FSEL FSEL FSEL DuraVent 81

12 FasNSeal Special Gas Vent 88 Elbow Use to transition from a vertical to a horizontal run. Stabilizes a pitch towards the condensate drain for good condensate management. SIZE ORDER # STOK # 3 FSEL FSEL FSEL FSEL FSEL FSEL SIZE ORDER # STOK # 9" FSEL " FSEL FSEL FSEL FSEL Elbow Offsets obstructions as needed. llows for better condensate management and less back pressure. SIZE ORDER # STOK # 3 FSEL FSEL FSEL FSEL FSEL FSEL " FSEL " FSEL SIZE ORDER # STOK # 1 FSEL FSEL FSEL Elbow Offsets obstructions as needed. llows for better condensate management and less back pressure. SIZE ORDER # STOK # 3 FSEL FSEL FSEL FSEL FSEL FSEL SIZE ORDER # STOK # 9" FSEL " FSEL FSEL FSEL FSEL DuraVent

13 Special Gas Vent FasNSeal 15 Elbow Offsets obstructions as needed. llows for better condensate management and less back pressure. SIZE ORDER # STOK # SIZE ORDER # STOK # 3 FSEL " FSEL FSEL FSEL " FSEL FSEL FSEL FSEL FSEL FSEL FSEL Wide Mouth oot Tee Use to transition from horizontal to vertical. Provides improved flue gas flow with angled gradual transitions. an also be used as a manifold connection to gang boilers into a common vent. SIZE ORDER # STOK # 4" FSWT " 7" " 5" FSWT " " FSWT " " FSWT " FSWT " " FSWT " FSWT " " FSWT " " FSWT " " FSWT " Standard Tee Use for a 90 offset, or to combine connections from two or more appliances into a common vent. an also use as a condensate management point when used in conjunction with drain fitting. ll Standard Tees are completely welded. SIZE ORDER # STOK # 3 FST " FST FST FST FST SIZE ORDER # STOK # 9" FST " FST FST FST FST FST DuraVent 83

14 FasNSeal Special Gas Vent ranch Tee Use as a Tee increaser or as a manifold connection to gang boilers into a common vent. vailable in custom size combinations. SIZE ORDER # STOK # 4 x 4 x 3 FST x 5 x 3 FST x 6 x 5 FST Single-Wall Wye Use in place of any DuraVent tee for a 45 angle instead of 90 ; can be used as a manifold connection to gang multiple boilers into a common vent. SIZE ORDER # STOK # 6 FSWYE ½ 3 1/8 7 FSWYE /3 8 3/5 3 ½ 8 FSWYE / FSWYE / /10 4 / FSWYE / FSWYE " FSWYE / /8 6 3/5 16 FSWYE " " 7 1 " Single-Wall Increaser Wye Single Wall Use in place of any tee for a 45 angle instead of 90. The branch has a smaller diameter, so it can be used to increase to a larger diameter as a manifold connection to gang multiple boilers into a common vent. Maximum diameter increase is 6. vailable in custom size combinations. D SIZE ORDER # STOK # 45 D D1 6 x 8" FSWYE " 9 1 4" 3 3 8" 6 x 10" FSWYE " " 3 5 8" 6 x 1" FSWYE " 1 1 " 4" 8 x 10" FSWYE " " 4 3 8" 8 x 1" FSWYE " 1 3 4" 4 1 " 8 x 14" FSWYE " " 4 5 8" 10 x 1" FSWYE " 13 1 " 5 1 8" 10 x 14" FSWYE " 15" 5 3 8" 10 x 16" FSWYE " " 5 1 " 1 x 14" FSWYE " " 6 1 8" 84 DuraVent

15 Special Gas Vent FasNSeal Tee ap Use to cap Standard Tee, ranch Tee or oot Tee. Remove Tee ap to inspect the system; clean out debris or collected condensate. 3 SIZE ORDER # STOK # 3 FST FST FST FST FST FST SIZE ORDER # STOK # 9" FST " FST FST FST FST Universal ondensate Drain Use to properly manage corrosive condensates common with high efficiency gas appliances. For best results, install close to the appliance. an be used horizontally, vertically, or any angle in between. The top photo shows the 3-5 diameters with 5/8 straight tube; the bottom photo shows 6-16 diameters with a 1 IPS Fitting. SIZE ORDER # STOK # 3" FSUD " FSUD FSUD FSUD ¼ 7" FSUD ¼ 8 FSUD ¼ 9 FSUD ¼ 10 FSUD ¼ 1 FSUD ¼ 14" FSUD ¼ 16" FSUD ¼ Drain Fitting Use instead of Tee ap to manage condensates at the bottom of a vertical run. For vent systems larger than 5, use an IPS Drain Fitting SIZE ORDER # STOK # 3 FSDF FSDF FSDF DuraVent 85

16 FasNSeal Special Gas Vent IPS Drain Fitting Use to connect iron drain pipe to flow acidic condensates to a neutralization tank before disposal. Uses 1 NPT thread. SIZE ORDER # STOK # SIZE ORDER # STOK # 3 FSIPSDF FSIPSDF /8 13/8 4" FSIPSDF FSIPSDF FSIPSDF FSIPSDF FSIPSDF " FSIPSDF " FSIPSDF " FSIPSDF FSIPSDF Horizontal Drain Fitting Use to manage condensates in horizontal runs. Optimal when ganging multiple appliances into a common vent. The top photo shows the 3-5 diameters with 5/8 straight tube; the bottom photo shows 6-16 diameters with a 1 IPS Fitting. SIZE ORDER # STOK # 3" FSHDF ½ 5/8 4" FSHDF ½ 5/8 5" FSHDF ½ 5/8 6" FSHDF /8 1 ¼ 7" FSHDF /8 1 ¼ 8" FSHDF /8 1 ¼ 9 FSHDF /8 1 ¼ 10 FSHDF /8 1 ¼ 1 FSHDF /8 1 ¼ 14 FSHDF /8 1 ¼ 16 FSHDF /8 1 ¼ Horizontal Drip Tee Use to manage condensate in horizontal runs. SIZE ORDER # STOK # 3" FSHDT " FSHDT DuraVent

17 Special Gas Vent FasNSeal ird Screen Use for 3 and 4 standard through-the-wall terminations. heck installation instructions for restrictions on horizontal terminations, such as minimum distance from windows and doors. SIZE ORDER # STOK # 3" FSS " FSS ird Screen Use for 5 to 16 through-the-wall termination. Deters rain and other elements from entering the vent system. heck installation instructions for restrictions on horizontal terminations, such as minimum distance from windows and doors. SIZE ORDER # STOK # 5 FSS FSS " FSS FSS FSS FSS FSS " FSS " FSS Termination Tee Use for standard and high-wind through-the-wall terminations. heck installation instructions for restrictions on horizontal terminations, such as minimum distance from windows and doors. SIZE ORDER # STOK # 3 FSTT FSTT FSTT FSTT Termination ox Use for horizontal through-the-wall terminations. heck installation instructions for restrictions on horizontal terminations, such as minimum distance from windows and doors. SIZE ORDER # STOK # 3" FST " FST DuraVent 87

18 FasNSeal Special Gas Vent Wall Thimble w/ Termination Damper MIN MX Use for horizontal through-the-wall terminations. heck installation instructions for restrictions on horizontal cap terminations, such as minimum distance from windows and doors. ccommodates wall thickness of to 8 1. Damper prevents backdraft of cold air to appliance. SIZE ORDER # STOK # 3" FSWTT " 4" FSWTT " FSWTT Wall Thimble w/ VL Use for through-the-wall termination. Fits between standard wall studs. 3-5 diameters accommodates wall thickness of to diameters accommodate wall thickness of to VL pipe allows for adjustability in length variance. 18 MIN MX SIZE ORDER # STOK # 3 FSWT " 4 FSWT FSWT FSWT " FSWT FSWT FSWT FSWT FSWT " FSWT " 16" FSWT Wall Pass Through *MIN 4 ¼, MX 8 ½ MIN 5 ¾, MX 11 ½ Use for through-the-wall termination. Fits between standard wall studs. 3-5 diameters accommodates wall thickness of to diameters accommodate wall thickness of to SIZE ORDER # STOK # 3" FSWPT " FSWPT FSWPT FSWPT " FSWPT FSWPT SIZE ORDER # STOK # 9 FSWPT FSWPT FSWPT " FSWPT " FSWPT DuraVent

19 Special Gas Vent FasNSeal Wall Thimble Sleeve Extension Use to add 6 of length to Wall Pass Through and Wall Thimble for thicker walls. SIZE ORDER # STOK # 3 FSWTE FSWTE FSWTE FSWTE " FSWTE FSWTE FSWTE FSWTE FSWTE " FSWTE " FSWTE Firestop/Flat Flashing Use when penetrating floor levels. SIZE ORDER # STOK # SIZE ORDER # STOK # 3 FSFS FSFS FSFS FSFS " FSFS FSFS FSFS FSFS FSFS " FSFS " FSFS Support lamp Use to support vertical and horizontal runs using threaded rod. Recommended every 10 on vertical runs and every 6 in horizontals. Use additional Support lamps as needed. SIZE ORDER # STOK # SIZE ORDER # STOK # 3 FSL FSL FSL FSL FSL FSL FSL " FSL " FSL " FSL FSL DuraVent 89

20 FasNSeal Special Gas Vent Wall racket Use to support vent pipe or tee sections. Provides proper clearance to combustibles. SIZE ORDER # STOK # 3 FSW FSW FSW FSW " FSW FSW SIZE ORDER # STOK # 9 FSW FSW FSW " FSW " FSW djustable Wall racket 3/8 6 4 Use to support vent pipe in lateral and horizontal runs. ssist in achieving proper pitch for condensate management. djusts up to 3. SIZE ORDER # STOK # 3 FSW FSW Rain ap Use to terminate above the roof line. When terminating above 1 vent diameter use a Termination one. 3" - 9" 10" - 16" SIZE ORDER # STOK # 3 FSR FSR FSR FSR " FSR FSR FSR FSR ¾ FSR FSR ½ 6 16 FSR ¾ DuraVent

21 Special Gas Vent FasNSeal Severe Weather Rain ap Use where high winds and horizontal rain are present. For vertical termination only. SIZE ORDER # STOK # 4 FSSWR Termination one Use for vertical termination. reates static back pressure to adjust harmonics. Venturi effect increases velocity of flue gases. Reduced opening provides for a smaller cross section to deter rain from entering the system. dditional cones available in 1" or " reduction in diameter. SIZE ORDER # STOK # 5 x 4 FSN x 10 FSN x 1 FSN x 14 FSN Storm ollar Use to create a weather tight seal between the pipe and flashing. SIZE ORDER # STOK # 3 FS FS FS FS " FS FS SIZE ORDER # STOK # 9 FS FS FS " FS " FS DuraVent 91

22 FasNSeal Special Gas Vent Variable Pitch Roof Jack Use as a heat shield within the flashing. Maintains center-line and clearance to combustibles. 18 SIZE ORDER # STOK # 3 FSVRJ FSVRJ FSVRJ FSVRJ " FSVRJ FSVRJ SIZE ORDER # STOK # 9 FSVRJ FSVRJ FSVRJ " FSVRJ " FSVRJ Variable Pitch Roof Flashing Use to create a weather-tight penetration where the vent pipe passes through the roof. Roof Jack and Storm ollar required accommodates flat to 9/1 roof pitch. SIZE ORDER # STOK # 3 FSVPF FSVPF FSVPF FSVPF " FSVPF FSVPF SIZE ORDER # STOK # 9 FSVPF FSVPF FSVPF " FSVPF " FSVPF Tall one Roof Jack Use as a heat shield within the flashing. Maintains center-line and clearance to combustibles. Use with Tall one Flashings. 18 SIZE ORDER # STOK # 3 FSRJ " 4" FSRJ " 5" FSRJ " 6" FSRJ " 7" FSRJ " 8" FSRJ " SIZE ORDER # STOK # 9" FSRJ " 10" FSRJ " 1" FSRJ " 14" FSRJ " 16" FSRJ " 9 DuraVent

23 Special Gas Vent FasNSeal Tall one Flashing Use to create a weather-tight penetration where the vent passes through a flat roof. Roof Jack and Storm ollar required. 1 SIZE ORDER # STOK # 3 FSF " FSF " FSF " FSF " FSF " FSF SIZE ORDER # STOK # 9" FSF " FSF " FSF " FSF " FSF Tapered Increaser Use to increase vent diameter. reates a smooth transition for an undisruptive flow. dditional sizes available up to a maximum of 10" diameter change. SIZE ORDER # STOK # 3 x 4 FS0304TI x 5 FS0405TI Eccentric Increaser Use to transition to a larger diameter pipe. Prevents condensate puddling when used on horizontal runs. ids in reducing formation of condensates. dditional sizes available up to a maximum of 10" diameter change. SIZE ORDER # STOK # 3 x 4 FS0304EI x 5 FS0405EI Stepped Increaser 6 Use to increase vent diameter when space constraints are an issue. More increasers available, contact customer service for information. SIZE ORDER # STOK # 3 x 4 FS34I x 5 FS45I DuraVent 93

24 FasNSeal Special Gas Vent Tapered Reducer Use to reduce vent diameter. reates a smooth transition for an undisruptive flow. dditional sizes available, but reductions are limited to a maximum of " reduction in diameter. SIZE ORDER # STOK # 4 x 3 FS0403TR " x 4 FS0504TR " Stepped Reducer 6 Use to reduce vent diameter when space constraints are an issue. vailable in custom size combinations. SIZE ORDER # STOK # 4 x 3 FS43R x 4 FS54R Double-Wall dapter Use to transition from a single-wall pipe to double-wall pipe. To transition from double-wall to single-wall, please reference single-wall adapter available in double-wall FasNSeal section. Ø SIZE ORDER # STOK # 3 FS-SWDW FS-SWDW SIZE ORDER # STOK # 9 FS-SWDW FS-SWDW FS-SWDW FS-SWDW FS-SWDW " FS-SWDW " FS-SWDW " FS-SWDW FS-SWDW DuraVent

25 Special Gas Vent FasNSeal Standard Wall Mount Kit Kit includes: Wall Thimble w/ Termination, djustable 90 Elbow, and Universal ppliance dapter. Use to vent wall mounted boilers or tankless water heaters. Terminates through-the-wall only. vailable in 3, 4 and 5 vent diameters. djust vertically from 16 1 to 1 and horizontally from 8 to & 4 compatible with most gas-burning appliances. 5 compatible with tankless. SIZE ORDER # STOK # 3 FSWMK FSWMK " FSWMK Severe Weather Kit Kit includes: Wall Thimble w/ Termination Tee, djustable 90 Elbow, and Universal ppliance dapter w/ondensate Drain and ack Draft Preventer. Use to vent wall mounted boilers or tankless water heaters. Use in areas of extreme wet and cold weather. Designed to prevent appliance freeze-up while maintaining an obstruction free exhaust. vailable in 4 vent diameters, compatible with most 4 exhaust gas appliances. dd a 90 Elbow and Vent Length on the outside of the house to clear high snow lines. SIZE ORDER # STOK # 4 FSSWWMK Variable Pitch Flashing Kit Kit includes: Rain ap, Storm ollar, Roof Jack, and Roof Flashing. (*VPK Kit includes: a Universal ppliance dapter w/ ondensate Drain). Use to terminate through-the-roof vent systems. Kit accommodates flat to 9/1 roof pitch. SIZE ORDER # STOK # 3 FSVPK " FSVPK " FSVPK4* FSVPK FSVPK " FSVPK FSVPK SIZE ORDER # STOK # 9 FSVPK FSVPK FSVPK " FSVPK " FSVPK DuraVent 95

26 FasNSeal Special Gas Vent 90 ird Screen Wall Mount Kit Kit includes: 90 ird Screen Termination, Wall Thimble, djustable 90 Elbow, and Universal ppliance dapter. Use to vent wall mounted boilers or tankless water heaters. 3 kit adjusts vertically from 14 1 to 19 and horizontally from 9 to kit adjusts vertically from 14 to 18 1 and horizontally from 9 to ompatible with all Rheem gas appliances. 3 kit requires a FS-RI-4. dapter. SIZE ORDER # STOK # 3 FSWMKE FSWMKE eiling Mounted Heater Vent Kit Kit includes Termination Tee, Wall Thimble w/djustable Vent Length, () 1 Vent Lengths, and Universal ppliance dapter. *4 kit includes Universal ppliance dapter with ondensate Drain. Use to vent ceiling mounted heaters, through-the-wall termination only. SIZE ORDER # STOK # 3 FSMK FSMK Universal oncentric Kit Use for through-the-wall termination with direct vent wall mounted gas appliances. an adjustable right and left hand air intake snout and accommodates wall thickness of heck installation instructions for restrictions on horizontal termination, such as minimum distance from windows and doors. SIZE ORDER # STOK # 4 FSEDVWMT04U FSEDVWMT05U Wall Mount oncentric Kit Use for through-the-wall termination with direct vent wall mounted gas appliances. Features a fixed right or left hand air intake snout and accommodates a maximum of 8 wall thickness. heck installation instructions for restrictions on horizontal termination, such as minimum distance from windows and doors. SIZE ORDER # STOK # 4 FDVWMT0403RH max. 4 FDVWMT0403LH max. 4 FDVWMT04RH max. 4 FSEDVWMT04LH max. 96 DuraVent

27 Special Gas Vent FasNSeal W Remote oncentric Kit Use for through-the-wall termination with direct vent gas appliances located away from the wall. heck installation instructions for restrictions on horizontal termination, such as minimum distance from windows and doors. SIZE ORDER # STOK # 3 FDVMT max. 4 FDVWT max. 4 FDVWT max DuraVent 97

FasNSeal 80/90 FasNSeal & FasNSeal W2 FasNSeal Flex

FasNSeal 80/90 FasNSeal & FasNSeal W2 FasNSeal Flex FasNSeal 80/90 FasNSeal & FasNSeal W FasNSeal Flex FSNSEL 80/90 hange to High Efficiency? Utilize Your Existing ommon Vent! FasNSeal 80/90 ap LISTINGS Storm ollar Flashing DuraVent s FNS 80/90 ombination

More information

AL29-4C (UNS S44735) Direct Vent System for Category II, III & IV Heating Equipment 3 through 16

AL29-4C (UNS S44735) Direct Vent System for Category II, III & IV Heating Equipment 3 through 16 L29- (UNS S7) Direct Vent System for ategory II, III & IV Heating Equipment through Set the standard as the first vent system with a built-in gasket and locking band, designed for high efficiency gas heaters

More information

CVS. Venting System for Category II, III, and IV gas appliances. Listed to UL-1738 and ULC S636.

CVS. Venting System for Category II, III, and IV gas appliances. Listed to UL-1738 and ULC S636. VS Venting System for ategory II, III, and IV gas appliances. Listed to UL-1738 and UL S636. PelletVent venting system. Listed to UL 641, UL S609, and UL/ORD 441. Unitized venting system for DirectVent

More information

FasNSeal. M&G DuraVent s Single-Wall Special Gas Vent Commerical Venting

FasNSeal. M&G DuraVent s Single-Wall Special Gas Vent Commerical Venting M&G DuraVent s Single-Wall Special Gas Vent FasNSeal 3-4 ommerical Venting Set the standard as the first vent system with a built-in gasket and locking band, designed for high efficiency gas heaters where

More information

Technical and Dimensional Data. Saf-T Vent SC Plus

Technical and Dimensional Data. Saf-T Vent SC Plus Technical and Dimensional Data Saf-T Vent S Plus 3"/5" & 4"/7" oncentric Reduced learance Double Wall for Special Gas Vent and/or Sealed ombustion Systems lso For Venting Listed Gas or Oil Fired ppliances

More information

PelletVent Pro. Biofuel venting system. UL 641, ULC S609, and ULC/ORD C441.

PelletVent Pro. Biofuel venting system. UL 641, ULC S609, and ULC/ORD C441. PelletVent Pro iofuel venting system. UL 641, ULC S609, and ULC/ORD C441. Specifications pplications PelletVent Pro is a venting system designed for stoves and inserts that use wood pellets and oil fuel.

More information

DURAVENT POLYPRO VENTING PRODUCTS

DURAVENT POLYPRO VENTING PRODUCTS DURVENT POLYPRO VENTING PRODUCTS INDEX FLEX VENTING SYSTEM DPTER KIT... 14-11 -VENT RETROFIT DPTERS... 14-10 CHIMNEY CP... 14-10 CHIMNEY LINING KIT... 14-10 CHIMNEY SUPPORT... 14-11 COUPLER DPTER... 14-12

More information

ULC S636 System. PolyPro. PolyPro Flex. Terminations

ULC S636 System. PolyPro. PolyPro Flex. Terminations PolyPro Polypropylene venting products for high-efficiency condensing appliance installations. Chloride free, environmentally safe. Listed to ULC-S636. Specifications pplications PolyPro is a polypropylene

More information

DirectVent Pro CVS. Unitized, co-axial venting system for direct vent gas or propane stoves, and fireplaces.

DirectVent Pro CVS. Unitized, co-axial venting system for direct vent gas or propane stoves, and fireplaces. DirectVent Pro Unitized, co-axial venting system for direct vent gas or propane stoves, and fireplaces. VS Venting System for ategory II, III, and IV gas appliances. Listed to UL-1738 and UL S636. Specifications

More information

PelletVent Multi-fuel venting system. UL 641.

PelletVent Multi-fuel venting system. UL 641. PelletVent Multi-fuel venting system. UL 641. Specifications Applications PelletVent is designed for venting of pellet stoves and inserts. Consult appliance manual for additonal requirements. Materials

More information

DuraPlus HTC. All-fuel, double-wall chimney system. ULC S629.

DuraPlus HTC. All-fuel, double-wall chimney system. ULC S629. DuraPlus HTC ll-fuel, double-wall chimney system. ULC S629. Specifications pplications DuraPlus HTC is a double-wall, all-fuel chimney system for both the U.S. and Canada for use with wood stoves; fireplaces;

More information

NovaVent. Dimensional Data

NovaVent. Dimensional Data NovaVent Dimensional Data NovaVent The new vent system designed and engineered for today s competitive sales environment. NovaVent NovaVent is designed and engineered to meet the requirements of gas-fired

More information

PelletVent Pro horizontal Kit. PelletVent Pro. PelletVent Pro Vertical Kit - Cathedral. PelletVent Pro Pellet Chimney

PelletVent Pro horizontal Kit. PelletVent Pro. PelletVent Pro Vertical Kit - Cathedral. PelletVent Pro Pellet Chimney PelletVent Pro horizontal Kit Kit includes: Round horizontal Cap, Wall Thimble, and Appliance Adapter. Pipe lengths not included. 4 Kit includes a 3-4 Appliance Adapter/Increaser, painted black. 3 3PVP-KHA

More information

FLANGED CORR/GUARD CORR/GUARD INSTALLATION INSTRUCTIONS

FLANGED CORR/GUARD CORR/GUARD INSTALLATION INSTRUCTIONS CORR/GUARD INSTALLATION INSTRUCTIONS This symbol on the nameplate means this product is listed by Underwriters Laboratories Inc. Tested to UL1738 / CAN / ULCS636-08 Listing No. MH26687 Testing No. 11EN

More information

PelletVent Pro. Biofuel venting system. UL 641, ULC S609, and ULC/ORD C441.

PelletVent Pro. Biofuel venting system. UL 641, ULC S609, and ULC/ORD C441. PelletVent Pro iofuel venting system. UL 641, ULC S609, and ULC/ORD C441. Specifications Applications PelletVent Pro is a venting system designed for stoves and inserts that use wood pellets and oil fuel.

More information

ANY EVERY ONE ONE No matter what the venting application, from gas fired to oil to all fuel heating equipment, Z-FLEX is your one-stop solution.

ANY EVERY ONE ONE No matter what the venting application, from gas fired to oil to all fuel heating equipment, Z-FLEX is your one-stop solution. NY EVERY ONE ONE No matter what the venting application, from gas fired to oil to all fuel heating equipment, Z-FLEX is your one-stop solution. Specialists in Flexible Z-FLEX has been providing flexible

More information

All-fuel, double-wall chimney system. UL 103 HT, UL 103, and ULC S604.

All-fuel, double-wall chimney system. UL 103 HT, UL 103, and ULC S604. DuraTech ll-fuel, double-wall chimney system. UL 103 HT, UL 103, and UL S60. DuraTech ll-fuel himney Typical Installations For 5-2 DuraTech *updated typicals* 6 1 19 8 16 1 19 5 1 8 1 6 2 Installation

More information

Combustion Air System DVL. DuraBlack. Triple-wall stovepipe system designed to provide air for combustion through its components. ULC S641.

Combustion Air System DVL. DuraBlack. Triple-wall stovepipe system designed to provide air for combustion through its components. ULC S641. Combustion ir System Triple-wall stovepipe system designed to provide air for combustion through its components. ULC S641. DVL Double-wall interior close clearance stovepipe for connecting woodstoves to

More information

Corr/Guard PRESSURE RATED VENTING SYSTEM IMPORTANT: DO NOT INSTALL WITHOUT FIRST READING THESE INSTRUCTIONS VERY CAREFULLY.

Corr/Guard PRESSURE RATED VENTING SYSTEM IMPORTANT: DO NOT INSTALL WITHOUT FIRST READING THESE INSTRUCTIONS VERY CAREFULLY. CORR/GUARD INSTALLATION INSTRUCTIONS This symbol on the nameplate means this product is listed by Underwriters Laboratories Inc. Tested to UL1738 / CAN / ULCS636-1995 Listing No. MH26687 Testing No. 11EN

More information

PelletVent Pro. Biofuel venting system. UL 641, ULC S609, and ULC/ORD C441.

PelletVent Pro. Biofuel venting system. UL 641, ULC S609, and ULC/ORD C441. PelletVent Pro iofuel venting system. UL 641, ULC S609, and ULC/ORD C441. Specifications Applications PelletVent Pro is a venting system designed for stoves and inserts that use wood pellets and oil fuel.

More information

SMALL DIAMETER CORR/GUARD & SLEEVED CORR/GUARD

SMALL DIAMETER CORR/GUARD & SLEEVED CORR/GUARD CORR/GUARD INSTALLATION INSTRUCTIONS This symbol on the nameplate means this product is listed by Underwriters Laboratories Inc. Tested to UL1738 / CAN / ULCS636-08 Listing No. MH26687 Testing No. 11EN

More information

FasNSeal. Installation Instructions

FasNSeal. Installation Instructions Installation Instructions FasNSeal & FasNSeal W2 Single-wall and Double-wall special gas vent FasNSeal Flex Flexible chimney liner for special gas vent for Category II, III, and IV appliances FasNSeal

More information

SUBMITTAL RECORD. ULC S636 - PolyPro. Single-Wall Double-Wall Concentric Flex

SUBMITTAL RECORD. ULC S636 - PolyPro. Single-Wall Double-Wall Concentric Flex SUMITTL RECORD ULC S636 - PolyPro Polypropylene vent pipe for use with NSI Category II and IV gas-burning appliances, including high efficiency water heaters, condensing boilers and warm air furnaces.

More information

Easy to assemble. Silicone gasket sealed. Laser-welded seams. Smooth joint connections. 360 Lock-Tab secure rotation

Easy to assemble. Silicone gasket sealed. Laser-welded seams. Smooth joint connections. 360 Lock-Tab secure rotation Easy to assemble Silicone gasket sealed Laser-welded seams Smooth joint connections 360 Lock-Tab secure rotation Evenly spaced inner and outer pipes Continuous column of air insulation Ultimate Pellet

More information

By Bernard Dalsin Mfg. Co. Installation and Operating Instructions Read these instructions and keep them for future reference

By Bernard Dalsin Mfg. Co. Installation and Operating Instructions Read these instructions and keep them for future reference By Bernard Dalsin Mfg. Co. 5205 208 th St Farmington MN 55024 L-VENT TYPE 3 "and 4" Factory-built venting system for wood pellet, corn or biomass and low-temperature gas or liquid fuel appliances Installation

More information

Combustion Air System DVL. DuraBlack. Triple-wall stovepipe system designed to provide air for combustion through its components. ULC S641.

Combustion Air System DVL. DuraBlack. Triple-wall stovepipe system designed to provide air for combustion through its components. ULC S641. System Triple-wall stovepipe system designed to provide air for combustion through its components. ULC S641. DVL Double-wall interior close clearance stovepipe for connecting woodstoves to chimney. ULC

More information

Bring In the Fresh Air

Bring In the Fresh Air ring In the Fresh Air ombustion Air System For DuraTech, DuraPlus HT and PelletVent Pro DuraVent s new, exclusive, patentpending DuraPro ombustion Air System Wall Thimble and eiling Support oxes is the

More information

flexible venting simply perfect cost efficient convenient durable Est FREEDOM VENTING FLEX

flexible venting simply perfect cost efficient convenient durable Est FREEDOM VENTING FLEX flexible venting simply perfect cost efficient convenient durable Est. 1990 FLEX FREEDOM VENTING Introduction Freedom Flex Venting systems are top of the line when it comes to materials, cost efficiency

More information

Z-VENT MODEL SVE SERIES III INSTALLATION AND MAINTENANCE INSTRUCTIONS

Z-VENT MODEL SVE SERIES III INSTALLATION AND MAINTENANCE INSTRUCTIONS Z-VENT MODEL SVE SERIES III INSTALLATION AND MAINTENANCE INSTRUCTIONS 3 & 4 SPECIAL STAINLESS STEEL VENTING SYSTEM FOR GAS BURNING APPLIANCES CATEGORY I, II, III, & IV TESTED AND LISTED BY UNDERWRITERS

More information

2012 INTERNATIONAL FUEL GAS CODE VENTS

2012 INTERNATIONAL FUEL GAS CODE VENTS 2012 INTERNATIONAL FUEL GAS CODE SECTION 502 (IFGC) VENTS 502.1 General. All vents, except as provided in Section 503.7, shall be listed and labeled. Type B and BW vents shall be tested in accordance with

More information

Twin wall Air Gap Insulated Zalutite & Aluminium Commercial Gas Vent Chimney System

Twin wall Air Gap Insulated Zalutite & Aluminium Commercial Gas Vent Chimney System Q Twin wall ir Gap Insulated Zalutite & luminium ommercial Gas Vent himney System Designed for Individual and Modular Natural Draught Gravity Flow himney pplications PRODUT INFORMTION INTRODUTION Q is

More information

GAS FIRED BOILERS FOR FORCED HOT WATER VENTING ADDENDUM. ECR International Ltd. - Olsen Division P.O. Box 900 Wallaceburg, Ont.

GAS FIRED BOILERS FOR FORCED HOT WATER VENTING ADDENDUM. ECR International Ltd. - Olsen Division P.O. Box 900 Wallaceburg, Ont. ODV-B GAS FIRED BOILERS FOR FORCED HOT WATER VENTING ADDENDUM ECR International Ltd. - Olsen Division P.O. Box 900 Wallaceburg, Ont. N8A5E5 TABLE OF CONTENTS HORIZONTAL PIPING... PAGES 1-10 WARNINGS...

More information

Mitchell Metal Products, Inc.

Mitchell Metal Products, Inc. Mitchell Metal Products, Inc. Mitchell Metal Products Kosciusko, Mississippi Established 1924 H i g h w a y 1 2 E P. O. B o x 7 8 9 K o s c i u s k o, M S 3 9 0 9 0 O f f i c e : 6 6 2-2 8 9-7 11 0 o r

More information

PolyPro: For Venting Condensing Appliances Environmentally Safe Alternative Lower Over-All Cost Than PVC Engineered Terminations Fast, Easy To Install

PolyPro: For Venting Condensing Appliances Environmentally Safe Alternative Lower Over-All Cost Than PVC Engineered Terminations Fast, Easy To Install PolyPro : For Venting Condensing Appliances Environmentally Safe Alternative Lower Over-All Cost Than PVC Engineered Terminations Fast, Easy To Install Being Green, Being Responsible. DuraVent looks for

More information

Pellet Stove. Flex Pipe. Appliance Connector

Pellet Stove. Flex Pipe. Appliance Connector Installation Instructions & Owners Maintenance Guide DT-M Direct-Temp for Multi Fuel L-Vent / Vent System for Pellet, Corn and other Bio-Fuel Burning Appliances Introduction Direct-Temp for Multi-Fuel

More information

BDM Direct Vent systems are for use with direct vent gas fired appliances.

BDM Direct Vent systems are for use with direct vent gas fired appliances. INSTALLATION INSTRUCTIONS Pro-Form DIRECT VENT SYSTEM Tested to ANSI Z21.88-2009 /CSA 2.33-2009 REPORT # 369-P-02b-6.5 Read through all venting and appliance instructions before beginning your installation.

More information

Installation and Maintenance Instructions

Installation and Maintenance Instructions Commercial & Industrial Positive Pressure or Condensing AL 29-4C Stainless Steel High Challenge Special Gas Vent Also for Natural Draft Appliances 3",4",5",6",7",8",9",10" and 12" Diameter Special Gas

More information

5"x 8" DIRECT VENT INSTALLATION INSTRUCTIONS FOR DECORATIVE GAS APPLIANCES AND DIRECT VENT HEATERS APPLICATION

5x 8 DIRECT VENT INSTALLATION INSTRUCTIONS FOR DECORATIVE GAS APPLIANCES AND DIRECT VENT HEATERS APPLICATION 5"x 8" DIRECT VENT INSTALLATION INSTRUCTIONS FOR DECORATIVE GAS APPLIANCES AND DIRECT VENT HEATERS APPLICATION These instructions apply to the Simpson Dura-Vent 5"x 8" Direct Vent System. This venting

More information

VENT SYSTEM COMPONENTS

VENT SYSTEM COMPONENTS Chimney Liner Kits Chimney Liners - All Fuel Chimney Liners - Gas Made from durable, corrosion-resistant type 316 stainless steel Designed to be used with wood, oil, coal and non-condensing gas-fired appliances

More information

C. Manufactured double wall chimneys for fuel fired equipment. D. NFPA 54 - National Fuel Gas Code; National Fire Protection Association; 2009.

C. Manufactured double wall chimneys for fuel fired equipment. D. NFPA 54 - National Fuel Gas Code; National Fire Protection Association; 2009. SECTION 235100 - BREECHINGS, CHIMNEYS, AND STACKS PART 1 GENERAL 1.1 SECTION INCLUDES A. Fabricated breechings. B. Manufactured chimneys for gas fired equipment. C. Manufactured double wall chimneys for

More information

Venting System For Pellet and Corn Stoves. PelletVent Pro. C o m p l e t e V e n t i n g S o l u t i o n s f o r t h e H e a r t h I n d u s t r y

Venting System For Pellet and Corn Stoves. PelletVent Pro. C o m p l e t e V e n t i n g S o l u t i o n s f o r t h e H e a r t h I n d u s t r y Venting System For Pellet and Corn Stoves PelletVent Pro C o m p l e t e V e n t i n g S o l u t i o n s f o r t h e H e a r t h I n d u s t r y ii PelletVent Pro For Stoves Burning Pellets & Corn Simpson

More information

The intelligent alternative for flue gas venting systems

The intelligent alternative for flue gas venting systems The intelligent alternative for flue gas venting systems FIRST LISTED InnoFlue is the first polymeric vent system tested and listed to ULC-S636 and UL-1738 in North America Intelligent for a good reason

More information

Installation and Maintenance Instructions

Installation and Maintenance Instructions Installation and Maintenance Instructions Saf-T Vent Model EZ Seal Single Wall AL 29-4C Stainless Steel Gas Vent Connector Chimney Liner & Special Gas Vent (USA) / Type BH Vent Class I/II (Canada) For

More information

Installation and Maintenance Instructions

Installation and Maintenance Instructions Installation and Maintenance Instructions Saf-T Vent Model EZ Seal and Model GC Single Wall AL 29-4C Stainless Steel Gas Vent Connector Chimney Liner & Special Gas Vent (USA) / Type BH Vent Class I/II

More information

Installation Instructions

Installation Instructions Installation Instructions Type B Gas Vent Model E/R 3" 8" ECCO TYPE B GAS VENT AND ACCESSORIES ARE FOR USE ONLY WITH LISTED CATEGORY 1 GAS-FIRED APPLIANCES OR APPLIANCES LISTED FOR USE WITH TYPE B GAS

More information

Advanced Venting Systems

Advanced Venting Systems Advanced Venting Systems 1 Z-Vent Special Gas Vent 3 Flexible Vent Connector Systems 5 Aluminium Chimney Liner System 7 Stainless Steel Chimney Liner System 9 Oval Liner System / Advancing the Industry

More information

Direct Vent System. for PELLET STOVES FEATURES. Includes all Selkirk Model VP Pellet Pipe and Direct-Temp components needed to complete a system

Direct Vent System. for PELLET STOVES FEATURES. Includes all Selkirk Model VP Pellet Pipe and Direct-Temp components needed to complete a system CTLOG Direct Vent System for PELLET STOVES Includes all Selkirk Model VP Pellet Pipe and Direct-Temp components needed to complete a system Direct-Temp for pellet stoves is the revolutionary, high-performance

More information

TYPE L VENT / VENT SYSTEM FOR PELLET BURNING APPLIANCES

TYPE L VENT / VENT SYSTEM FOR PELLET BURNING APPLIANCES INSTALLATION INSTRUCTIONS & MAINTENANCE GUIDE TYPE L VENT / VENT SYSTEM FOR PELLET BURNING APPLIANCES LISTED TO ULC-S609 & UL641 A MAJOR CAUSE OF VENT RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES

More information

Type B Gas Vent. Installation Instructions

Type B Gas Vent. Installation Instructions Installation Instructions Round and Oval Type B GasVent Systems for use with natural as or liquid propane category I and draft hood equipped appliances and appliances listed to use Type B Gas Vent. Type

More information

CHIMNEYS AND VENTS CHAPTER 8

CHIMNEYS AND VENTS CHAPTER 8 CHAPTER 8 CHIMNEYS AND VENTS SECTION 801 GENERAL 801.1 Scope. This chapter shall govern the installation, maintenance, repair and approval of factory-built chimneys, chimney liners, vents and connectors.

More information

GWS. Venting Manual. Gas-Fired Water Boilers. Hazard definitions. Contents. Venting method definitions

GWS. Venting Manual. Gas-Fired Water Boilers. Hazard definitions. Contents. Venting method definitions GWS Gas-Fired Water Boilers Venting Manual Hazard definitions Contents Page Hazards that will cause severe personal injury, death or substantial property damage. Hazards that can cause severe personal

More information

SL-VENT (oil and gas vent) For use with oil or gas fired appliances. Listed to ULC-609 and UL-641. Available in 5, 6, 7 and 8 I. D.

SL-VENT (oil and gas vent) For use with oil or gas fired appliances. Listed to ULC-609 and UL-641. Available in 5, 6, 7 and 8 I. D. Typical Installations 0 8 9 Vertical Installation. Vertical Termination ap. Storm ollar. Flashing. Roof Support. Length. ttic Radiation Shield. Firestop 8. ecorative lack Plate 9. Length (lack) 0. Insulation

More information

Model IVSI Positive Pressure Venting Systems

Model IVSI Positive Pressure Venting Systems C O M M E R C I A L A N D I N D U S T R I A L V E N T I N G Model IVSI Positive Pressure Venting Systems Ideal for discharging exhaust gases and fumes from boilers, heaters, ovens, engines, turbines and

More information

Installation and Maintenance Instructions

Installation and Maintenance Instructions Installation and Maintenance Instructions Saf-T Vent Model EZ Seal and Model GC Single Wall AL 29-4C Stainless Steel Gas Vent Connector Chimney Liner & Special Gas Vent (USA) / Type BH Vent Class I/II

More information

Gas Stoves. H15-10 Direct Vent Gas Stove. Model H15-NG10 H15-LP10. Approved Venting Systems

Gas Stoves. H15-10 Direct Vent Gas Stove. Model H15-NG10 H15-LP10. Approved Venting Systems H15-10 Direct Vent Gas Stove Model H15-NG10 H15-LP10 Fuel Type Natural Gas Propane Minimum Supply Pressure 5.0 W.C. (1.25 kpa) 12.0 W.C. (3.00 kpa) Manifold Pressure - High 3.8 W.C. (0.95 kpa) 11 W.C.

More information

CHAPTER 8 CHIMNEYS AND VENTS

CHAPTER 8 CHIMNEYS AND VENTS CHAPTER 8 CHIMNEYS AND VENTS SECTION 801 GENERAL 801.1 Scope. This chapter shall govern the installation, maintenance, repair and approval of factory-built chimneys, chimney liners, vents and connectors.

More information

Installation & Maintenance Instructions

Installation & Maintenance Instructions Installation & Maintenance Instructions Listed & Tested to UL641, ULC-S609, ULC/ORD C441 AMERIVENT Model PVP Pellet Pipe Plus Vent Connector for Pellet-Fuel Appliances and Other Low-Temperature Applications

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS ELIMINATOR 36 Wood Burning Fireplace Models: 36E Non-Circulating (Smooth Face) I36E Non-Circulating (Smooth Face) Fully Insulated INSTALLATION INSTRUCTIONS SAVE THIS BOOK This book is valuable. In addition

More information

Saf-T Vent Model EZ Seal Plus/EZ 316 Single Wall Gas Vent Connector Chimney Liner & Special Gas Vent (USA) / Type BH Vent Class I/II (Canada)

Saf-T Vent Model EZ Seal Plus/EZ 316 Single Wall Gas Vent Connector Chimney Liner & Special Gas Vent (USA) / Type BH Vent Class I/II (Canada) Installation and Maintenance Instructions Saf-T Vent Model EZ Seal Plus/EZ 316 Single Wall Gas Vent Connector Chimney Liner & Special Gas Vent (USA) / Type BH Vent Class I/II (Canada) For Venting Residential,

More information

Gas Stoves. C34-10 Direct Vent Gas Stove. Side wall E F. Back wall F E. Model C34-NG10 C34-LP10

Gas Stoves. C34-10 Direct Vent Gas Stove. Side wall E F. Back wall F E. Model C34-NG10 C34-LP10 Back wall Gas Stoves Model C34-NG10 C34-LP10 Fuel Type Natural Gas Propane Minimum Supply Pressure 5.0 W.C. (1.25 kpa) 12.0 W.C. (3.00 kpa) Manifold Pressure - High 3.8 W.C. (0.95 kpa) 11 W.C. (2.74 kpa)

More information

SUBJECT: SELKIRK MODEL DT DIRECT VENT SYSTEM FOR PELLET & CORN FIRED APPLIANCES / TERMINATION CLEARANCES TO OPENINGS IN BUILDINGS

SUBJECT: SELKIRK MODEL DT DIRECT VENT SYSTEM FOR PELLET & CORN FIRED APPLIANCES / TERMINATION CLEARANCES TO OPENINGS IN BUILDINGS Selkirk LLC Selkirk LLC Research & Development State Route 93 North & Sutton Road P.O. Box 631 Logan, OH 43138 9/21/2006 TO: Our Valued Customers FROM: Glen Edgar Director R&D SUBJECT: SELKIRK MODEL DT

More information

Installation and Maintenance Instructions

Installation and Maintenance Instructions Installation and Maintenance Instructions Saf-T Vent Model EZ Seal Single Wall AL 29-4C Stainless Steel Gas Vent Connector Chimney Liner & Special Gas Vent (USA) / Type BH Vent Class I/II (Canada) For

More information

200i. Vent/air manual. Installation instructions for vent and air piping. Also read and follow: 200i Boiler manual 200i Control manual

200i. Vent/air manual. Installation instructions for vent and air piping. Also read and follow: 200i Boiler manual 200i Control manual M2i-VAM-2 Cast iron condensing boiler 200i Vent/air manual Installation instructions for vent and air piping Also read and follow: 200i Boiler manual 200i Control manual This manual is intended only for

More information

Manual Addendum. This Addendum needs to be used in conjunction with the Evergreen Boiler Manual P/N _0518

Manual Addendum. This Addendum needs to be used in conjunction with the Evergreen Boiler Manual P/N _0518 Manual Addendum This Addendum needs to be used in conjunction with the Evergreen Boiler Manual P/N 550-100-191_0518 ATTENTION to installers and homeowners of Evergreen boilers. KEEP THIS ADDENDUM WITH

More information

P P Gas Fireplace. P See Thru

P P Gas Fireplace. P See Thru P121-10 - P131-10 Gas Fireplace Model P121/P131-NG10 P121/P131-LP10 Fuel Type Natural Gas Propane Minimum Supply Pressure 5 W.C. (1.25 kpa) 12 W.C. (3.00 kpa) Manifold Pressure - High 3.8 W.C. (0.95 kpa)

More information

Saf-T Vent SC Plus/SC 316

Saf-T Vent SC Plus/SC 316 Installation and Maintenance Instructions Saf-T Vent SC Plus/SC 316 Double Wall One Inch Air Space Special Gas Vent For Venting Residential and Light Commercial Appliances Category I,II,III,IV Appliances

More information

Installation and Maintenance Instructions. Double Wall AL 29-4C Stainless Steel Special Gas Vent and Type L Vent

Installation and Maintenance Instructions. Double Wall AL 29-4C Stainless Steel Special Gas Vent and Type L Vent Installation and Maintenance Instructions Saf-T Vent CI Plus Double Wall AL 29-4C Stainless Steel Special Gas Vent and Type L Vent For Venting Commercial & Industrial Appliances Condensing Appliances Category

More information

ICC Model VIC SINGLE WALL SPECIAL GAS VENT INSTALLATION AND MAINTENANCE INSTRUCTIONS

ICC Model VIC SINGLE WALL SPECIAL GAS VENT INSTALLATION AND MAINTENANCE INSTRUCTIONS ICC Model VIC SINGLE WALL SPECIAL GAS VENT INSTALLATION AND MAINTENANCE INSTRUCTIONS The ICC Model VIC is a listed venting system designed for venting commercial and industrial appliances, condensing appliances,

More information

Venting of Gas Fired Equipment RV

Venting of Gas Fired Equipment RV PLEASE DO NOT BOOKMARK ANY ANYTIMECE WEBPAGES! Our system will remember the last page you viewed when logging out and back in but please DO NOT exit out when taking a test. Your place will NOT be saved.

More information

INSTALLATION OF VENTING SYSTEM COMPONENTS WARNING

INSTALLATION OF VENTING SYSTEM COMPONENTS WARNING INSTALLATION OF VENTING SYSTEM COMPONENTS WARNING When installing the EVERHOT IGI model series direct vent water heaters, use only EVERHOT vent/air intake system kits and components. Installation and service

More information

H35 Direct Vent Gas Stove. 17,500 BTU/h (5.13 kw) 34,000 BTU/h (9.97 kw) 15,000 BTU/h (4.39 kw) 28,500 BTU/h (8.35 kw)

H35 Direct Vent Gas Stove. 17,500 BTU/h (5.13 kw) 34,000 BTU/h (9.97 kw) 15,000 BTU/h (4.39 kw) 28,500 BTU/h (8.35 kw) H35 Direct Vent Gas Stove Model H35-NG10 H35-LP10 Fuel Type Natural Gas Propane Minimum Supply Pressure 5.0 W.C. (1.25 kpa) 12.0 W.C. (3.00 kpa) Manifold Pressure - High 3.8 W.C. (0.94 kpa) 11 W.C. (2.74

More information

H35 Direct Vent Gas Stove. 17,500 BTU/h (5.13 kw) 34,000 BTU/h (9.97 kw) 15,000 BTU/h (4.39 kw) 28,500 BTU/h (8.35 kw)

H35 Direct Vent Gas Stove. 17,500 BTU/h (5.13 kw) 34,000 BTU/h (9.97 kw) 15,000 BTU/h (4.39 kw) 28,500 BTU/h (8.35 kw) H35 Direct Vent Gas Stove Model H35-NG10 H35-LP10 Fuel Type Natural Gas Propane Minimum Supply Pressure 5.0 W.C. (1.25 kpa) 12.0 W.C. (3.00 kpa) Manifold Pressure - High 3.8 W.C. (0.94 kpa) 11 W.C. (2.74

More information

Direct Exhaust Venting Kit Instructions

Direct Exhaust Venting Kit Instructions CONDENSING GAS BOILER 220/299/300/399 Direct Exhaust Venting Kit Instructions Evergreen 220/299/300/399 Kit part number 383-500-769 STOP! Read before proceeding Hazard definitions The following defined

More information

EXCEL. ULTRABlack THE MOST DURABLE, EASIEST TO INSTALL RESIDENTIAL CHIMNEY SYSTEM YOU CAN BUY NEVER EVER BUY ANOTHER STOVE PIPE

EXCEL. ULTRABlack THE MOST DURABLE, EASIEST TO INSTALL RESIDENTIAL CHIMNEY SYSTEM YOU CAN BUY NEVER EVER BUY ANOTHER STOVE PIPE THE MOST DURABLE, EASIEST TO INSTALL RESIDENTIAL CHIMNEY SYSTEM YOU CAN BUY ULTRABlack NEVER EVER BUY ANOTHER STOVE PIPE Chimney To determine what parts you need for your woodstove installation, try the

More information

ANY EVERY ONE ONE No matter what the venting application, from gas fired to oil to all fuel heating equipment, Z-FLEX is your one-stop solution.

ANY EVERY ONE ONE No matter what the venting application, from gas fired to oil to all fuel heating equipment, Z-FLEX is your one-stop solution. ANY EVERY ONE ONE No matter what the venting application, from gas fired to oil to all fuel heating equipment, Z-FLEX is your one-stop solution. Specialists in Flexible Z-FLEX has been providing flexible

More information

INSTALLATION AND OPERATING INSTRUCTIONS TABLE OF CONTENTS IMPORTANT

INSTALLATION AND OPERATING INSTRUCTIONS TABLE OF CONTENTS IMPORTANT C US This manual must be left with owner and should be hung on or adjacent to the boilerfor reference. COMMON VENTING MODELS CHS-300 through CHS-399 INSTALLATION AND OPERATING INSTRUCTIONS TABLE OF CONTENTS

More information

Installation Instructions. PolyPro Single-Wall Gas Vent System for Category II & IV Gas-Burning Appliances. PolyPro

Installation Instructions. PolyPro Single-Wall Gas Vent System for Category II & IV Gas-Burning Appliances. PolyPro Installation Instructions PolyPro Single-Wall Gas Vent System for Category II & IV Gas-Burning Appliances PolyPro A MAJOR CAUSE OF VENT RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES)

More information

Twin Wall Installation Instructions And Maintenance Guide

Twin Wall Installation Instructions And Maintenance Guide Twin Wall Installation Instructions And Maintenance Guide Please read all instructions before beginning your installation. Failure to install this system in accordance with these instructions will invalidate

More information

CHAPTER 8 CHIMNEYS AND VENTS

CHAPTER 8 CHIMNEYS AND VENTS CHAPTER 8 CHIMNEYS AND VENTS SECTION 801 GENERAL 801.1 Scope. This chapter shall govern the installation, maintenance, repair and approval of factory-built chimneys, chimney liners, vents and connectors.

More information

Venting Supplement. Direct Vent Through-Roof or Through-Unused-Chimney. Water Boiler Series 3 & 4

Venting Supplement. Direct Vent Through-Roof or Through-Unused-Chimney. Water Boiler Series 3 & 4 GOLD GV Water Boiler Series 3 & 4 Venting Supplement Direct Vent Through-Roof or Through-Unused-Chimney For use with Weil-McLain Through-Roof or Through- Unused-Chimney Termination Kit Kit part # 382-200-435

More information

GOLD GV. Venting Supplement for 3 venting. Water Boiler Series 3 & 4

GOLD GV. Venting Supplement for 3 venting. Water Boiler Series 3 & 4 GOLD GV Water Boiler Series 3 & 4 Venting Supplement for 3 venting Special gas vent system vent and combustion air supplement for 3 diameter venting. The following manufacturers AL29-4C Stainless Steel

More information

The Monterey (PENNINSULA) MODEL PN36 3-SIDED, WOOD-BURNING FIREPLACE

The Monterey (PENNINSULA) MODEL PN36 3-SIDED, WOOD-BURNING FIREPLACE The Monterey (PENNINSULA) MODEL PN36 3-SIDED, WOOD-BURNING FIREPLACE INSTALLATION AND OPERATING INSTRUCTIONS SAVE THIS BOOK This book is valuable. In addition to instructing you on how to install and maintain

More information

Installation Instructions. PolyPro Single-Wall Gas Vent System for Category II & IV Gas-Burning Appliances. PolyPro

Installation Instructions. PolyPro Single-Wall Gas Vent System for Category II & IV Gas-Burning Appliances. PolyPro Installation Instructions PolyPro Single-Wall Gas Vent System for Category II & IV Gas-Burning Appliances PolyPro A MAJOR CAUSE OF VENT RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES)

More information

VP Pellet Pipe. For pellet burning stoves. FEATURES

VP Pellet Pipe. For pellet burning stoves. FEATURES CATALOG VP Pellet Pipe For pellet burning stoves. Selkirk gives you the safe, efficient, and cost-effective venting system that's engineered precisely for pellet burning stoves. FEATURES Available in 3"

More information

INS A T LL T A ION, OPER T A ING AND SERVICE INSTRUCTIONS FOR FREEDOM CONDENSING HIGH EFFICIENCY DIRECT VENT GAS - FIRED HOT

INS A T LL T A ION, OPER T A ING AND SERVICE INSTRUCTIONS FOR FREEDOM CONDENSING HIGH EFFICIENCY DIRECT VENT GAS - FIRED HOT INSTALLATION, OPERATING AND SERVICE INSTRUCTIONS FOR FREEDOM CONDENSING HIGH EFFICIENCY DIRECT VENT GAS - FIRED HOT WATER BOILER Warning: Improper installation, adjustment, alteration, service or maintenance

More information

That s The Metal-Fab Way Experience The Difference

That s The Metal-Fab Way Experience The Difference 1 Faster. Safer. etter. Metal-Fab provides complete and comprehensive venting solutions to the HV, hearth and plumbing markets. Founded in 1959, on the premise that better products and services would be

More information

GB162 Concentric Horizontal Vent Kit

GB162 Concentric Horizontal Vent Kit GB162 Concentric Horizontal Vent Kit FOR BUDERUS GB162 SERIES BOILERS Installation Instructions 2 Concentric Horizontal Vent Kit Installation Manual Data subject to change Bosch Thermotechnology Corp.

More information

Installation Instructions. Venting System for Pellet, Corn, Oil, and Biofuel appliances. PelletVent Pro

Installation Instructions. Venting System for Pellet, Corn, Oil, and Biofuel appliances. PelletVent Pro Installation Instructions Venting System for Pellet, Corn, Oil, and Biofuel appliances. PelletVent Pro A MAJOR CAUSE OF VENT RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES) TO COMBUSTIBLE

More information

100% Manufactured in the UK. Nova SM. Twin wall, insulated stainless steel multi-fuel chimney system. Also suitable for fully condensing appliances

100% Manufactured in the UK. Nova SM. Twin wall, insulated stainless steel multi-fuel chimney system. Also suitable for fully condensing appliances 100% Manufactured in the UK Nova SM Twin wall, insulated stainless steel multi-fuel chimney system lso suitable for fully condensing appliances The Nova SM chimney system range is specifically designed

More information

Secure Seal. Single-Wall, Double-Wall and Double-Wall Insulated Special Gas Vent (US) (Canada)

Secure Seal. Single-Wall, Double-Wall and Double-Wall Insulated Special Gas Vent (US) (Canada) Secure Seal Single-Wall, Double-Wall and Double-Wall Insulated Special Gas Vent www.securitychimneys.com 800-361-4909 (US) 800-667-3387 (Canada) Secure Seal SS, SSD, SSID, & Flex QUALITY AND DEPENDABILITY

More information

GOLD. Venting Supplement. Water Boiler Series 3 & 4. for 3" venting

GOLD. Venting Supplement. Water Boiler Series 3 & 4. for 3 venting GOLD GV Water Boiler Series 3 & 4 Venting Supplement for 3" venting Special gas vent system vent and combustion air supplement for 3" diameter venting. The following manufacturers AL29-4C Stainless Steel

More information

PelletVent. Factory-Built Chimney Relining. Installation Instructions. PelletVent Pro (PVP)

PelletVent. Factory-Built Chimney Relining. Installation Instructions. PelletVent Pro (PVP) Installation Instructions PelletVent Pro (PVP) PelletVent Factory-Built Chimney Relining A MAJOR CAUSE OF VENT RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES) TO COMBUSTIBLE MATERIALS.

More information

Inspection Checklist Mechanical Rough in

Inspection Checklist Mechanical Rough in Property Owner Name: Property Address: Permit Number: Inspectors Name: Review Date: Permits and Plans 1. Job address is posted in a visible location. (R319.1) 2. Permit and approved plans are on site and

More information

CWD Series. Gas-Fired Direct Vent Hot Water Boilers INSTALLATION INSTRUCTIONS These instructions must be affixed on or adjacent to the boiler

CWD Series. Gas-Fired Direct Vent Hot Water Boilers INSTALLATION INSTRUCTIONS These instructions must be affixed on or adjacent to the boiler D E S I G N E D T O L E A D CWD Series Gas-Fired Direct Vent Hot Water Boilers INSTALLATION INSTRUCTIONS These instructions must be affixed on or adjacent to the boiler Models: CWD060 CWD083 CWD110 CWD138

More information

Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer

Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS UNDER CABINET HOOD Read All Instructions Thoroughly Before Beginning Installation WARNING

More information

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT Read All Instructions Thoroughly Before Beginning Installation WARNING

More information

Shasta Vent Inc All-Fuel HT Chimney Installation Instructions

Shasta Vent Inc All-Fuel HT Chimney Installation Instructions Shasta Vent Inc All-Fuel HT Chimney Installation Instructions August 2015 v1.02 A MAJOR CAUSE OF CHIMNEY RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES) TO COMBUSTIBLE MATERIALS.

More information

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT Read All Instructions Thoroughly Before Beginning Installation WARNING

More information

WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual.

WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual. Malm Fireplaces, Inc. 368 Yolanda Avenue - Santa Rosa, Ca 95404 (707) 523-7755 - Fax: (707) 571-8036 info@malmfireplaces.com 34 Zircon Direct Vent Tested & Listed by LabTest Certified for use in USA &

More information

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT Read All Instructions Thoroughly Before Beginning Installation WARNING

More information