FasNSeal 80/90 FasNSeal & FasNSeal W2 FasNSeal Flex
|
|
- Dwayne Lewis
- 5 years ago
- Views:
Transcription
1 FasNSeal 80/90 FasNSeal & FasNSeal W FasNSeal Flex
2 FSNSEL 80/90 hange to High Efficiency? Utilize Your Existing ommon Vent! FasNSeal 80/90 ap LISTINGS Storm ollar Flashing DuraVent s FNS 80/90 ombination at I and at IV gas vent system is designed and UL listed for use with approved DuraVents special gas vent components only! Listed to applicable portions of UL S/UL777, and UL44. FasNSeal Flex ttic Insulation Shield Square Firestop Support Double Wall Wye ME R -R E DY L OG OT Y P E UL M R K F OR N D ND T HE U.S. T hese Marks are registered by Underwriters L aboratories Inc. FasNSeal Flex to PolyPro dapter Firestop 4 /0 djustable Elbow PolyPro Pipe Length Draft Hood onnector Elbow Locking ands dapter onnector ppliance dapter LISTED MH7 FasNSeal 80/90 Feature enefit vailable in - 8 Vent Diameters. Fits most residential common vent systems. pproved for installation in other manufacturers Vent, with listed at I adapters available. Unmatched installation flexibility. T he minimum height of the registered trademark symbol shall be /4 of an inch. When the overall diameter of the UL Mark is less than /8 of an inch, the trademark symbol may be omitted if it is not legible to the naked eye. orrosion resistant SS steel flex liner. Superior flow performance allowing longer runs before upsizing, and superior condensate management. Withstands high temperatures inside at I vent. Dual path (at I / at IV) termination cap. Warm at I exhaust helps reduce icing on condensing at IV exhaust. Engineered sizing guidance for combined system. ddition of SS flex to orphaned common vent system helps reduce oversizing issues, enhances draft of remaining at I appliance. SS flexthas smooth inner wall. he font for all letter forms is Helvetica ondensed lack, except for the trademark symbol, which is Helvetica ondensed Medium. No other fonts are acceptable M//97 ompatible with portfolio of DuraVent special gas vent products, including Utilize exiting appliance adapters, current appliance approvals. PolyPro and FNS. Eliminates issues with Horizontal terminations, including wind effects, Vertical Termination. icing, code issues, etc. No additional building penetrations required, no disturbing finished ombined at I / at IV vent system takes up no additional space. internal spaces, etc. UL tested, listed engineered system. Industry first (and only) listing of it s kind.
3 STRIGHT UP INSTLLTION Description Order # Stock # WYE INSTLLTION 4 4 -Vent Firestop x -Vent Firestop FSFS-GVPP x -Vent Firestop FSFS-GVPP x -Vent Firestop FSFS-GVPP x -Vent Firestop FSFS-GVPP x -Vent Firestop FSFS-GVPP x4 -Vent Firestop FSFS-GVPP x -Vent Firestop FSFS-GVPP 8000 x -Vent Firestop FSFS-GVPP 800 x4 -Vent Firestop FSFS-GVPP4 800 x -Vent Firestop FSFS-GVPP 800 Universal Female dapter Female dapter GVF Female dapter 4GVF 8000 Female dapter GVF 8000 Female dapter GVF Female dapter 7GVF Female dapter 8GVF Double Wall Wye 4º ranch 4 x4 x Double Wall Wye 4GVY x4 x4 Double Wall Wye 4GVY x x4 Double Wall Wye 4GVY x x4 Double Wall Wye GVY x4 x4 Double Wall Wye GVY x4 x Double Wall Wye GVY x x4 Double Wall Wye GVY x4 x Double Wall Wye GVY x4 x4 Double Wall Wye GVY x4 x Double Wall Wye GVY x x Double Wall Wye GVY 8000 x4 x Double Wall Wye GVY x x Double Wall Wye 7GVY nnular Space - Effective Remaining Vent Diameter 0 at IV Liner 0 at IV Liner 04 at IV Liner 0 at IV Liner Vent 4 N/ N/ Vent 4 4 N/ 7 Vent 4 8 Vent Special Gas Vent FasNSeal Description Order # Stock # Vertical Terminations 0"x" ombo ap FS "x" ombo ap FS "x" ombo ap FS "x" ombo ap FS "x4" ombo ap FS "x" ombo ap FS "x" ombo ap FS "x4" ombo ap FS "x" ombo ap FS "x" ombo ap FS "x4" ombo ap FS "x" ombo ap FS "x" ombo ap FS8 800 FasNSeal Flex 0"x0' FasNSeal Flex FSFLEX "x' FasNSeal Flex FSFLEX "x0' FasNSeal Flex FSFLEX "x' FasNSeal Flex FSFLEX "x0' FasNSeal Flex FSFLEX "x00' FasNSeal Flex FSFLEX "x0' FasNSeal Flex FSFLEX " ustom FNS Flex FSFLEX-XX x 0 FasNSeal Flex FSFLEX x FasNSeal Flex FSFLEX x 0 FasNSeal Flex FSFLEX x FasNSeal Flex FSFLEX x 00 FasNSeal Flex FSFLEX x 0 FasNSeal Flex 4FSFLEX x FasNSeal Flex 4FSFLEX x 0 FasNSeal Flex 4FSFLEX x FasNSeal Flex 4FSFLEX x 00 FasNSeal Flex 4FSFLEX x 0 FasNSeal Flex FSFLEX x FasNSeal Flex FSFLEX x 0 FasNSeal Flex FSFLEX x FasNSeal Flex FSFLEX x FasNSeal Flex FSFLEX PP to FNS Flex dapter " PP to FNS Flex dapter FSSMM-PP " PP to FNS Flex dapter FSSMM-PP " PP to FNS Flex dapter FSSMM-PP " PP to FNS Flex dapter FSSMM-PP- DuraVent
4 FasNSeal Special Gas Vent Specifications pplications FasNSeal and FasNSeal Flex is for use with natural gas or propane ategories II, III and IV appliances or anada s Type H Gas Vent Systems, having a maximum rated operating temperature of 480 F and a maximum positive pressure of (FasNSeal Flex ") water column. FasNSeal can be used on a wide range of applications, including: high efficiency gas boilers, furnaces, booster heaters, pool heaters, water heaters, unit heaters, or tankless water heaters. FasNSeal W is ideal for use on commercial applications such as: office buildings, medical facilities, condos, or multiple unit apartment complexes where there is the need for low clearances to combustibles. In residential applications, FasNSeal W is the perfect solution for running between floor joists or in walls. Materials and onstruction FasNSeal 7 : L : L : L FasNSeal Flex Single strip double layer super-ferritic stainless steel (totalling.00 ). FasNSeal W : L9-4 stainless steel.0 inner wall, stainless steel.0 outer wall. 7 : L9-4 stainless steel.0 inner wall, stainless steel.04 outer wall. 8 : L9-4 stainless steel.09 inner wall, stainless steel.04 outer wall. 4 : L9-4 stainless steel.04 inner wall, stainless steel.04 outer wall. UL 78 and UL S Systems FasNSeal & FasNSeal W ll FasNSeal (single-wall) and FasNSeal W (double-wall) vent lengths and components feature patented built-in mechanical locking band and triple-lipped directional gaskets. ll pipes and components are engineered with smooth clean welds located 90 from mechanical locking bands. This construction feature allows for ease of installation. The ½ air space between the inner and outer wall on FasNSeal W helps to reduce the clearance to combustibles in addition to creating a heat shield for additional safety. ll FasNSeal components which come in contact with exhaust gases and condensates are now silicone free. This important design and manufacturing feature greatly reduces the chances of system breakdown and failure. The main problems with silicone are there are too many adhesion factors which are very difficult to control and the process of binding similar materials with an epoxy, which can weaken the bond over time. Welded seams ensure a leak-free product that is meant to last. FasNSeal Flex Made from super-ferritic stainless steel. orrosion resistant. Manufactured with a sure-seal locking seam for superior strength and flexibility. The smooth inner-wall provides for no output reduction, allowing for full appliance efficiency, ease of cleaning and regular maintenance. The smooth inner wall optimizes gas flow, minimizes back pressure, and facilitates condensate management. Flexible chimney liner is listed to UL 78 standard. Diameters FasNSeal (single- and double-wall) - FasNSeal Flex - Listings FasNSeal (single- and double-wall) ETL Listed to UL 78 and UL S. FasNSeal Flex UL Listed to UL 78 and UL 777 and UL S. 74 DuraVent
5 Special Gas Vent FasNSeal Typical Installations 4 Installation Key Rain ap 9 Universal ondensate Drain Storm ollar 0 ppliance dapter Variable Pitch Roof Flashing Top Plate* 4 Vent Length Female Flex dapter djustable Vent Length FasNSeal Flex Firestop/Flat Flashing 4 Male Flex dapter 7 Horizontal Drip Tee Standard Tee 8 Elbow Refer to our Typical Venting Installation drawings to select the appropriate component parts for your installation Multi-Story FasNSeal Offset FasNSeal Elbow Vent Length Termination/Wall Thimble with Volumetric Damper Universal ondensate Drain Tankless H0 ppliance dapter Offset with Tee FasNSeal Flex & FasNSeal DuraVent 7
6 D. USE NON-OMUSTILE HNGER EVERY SIX () FEET OF HORIZONTL RUN. 4. USE FIRE-RTED FIRESTOPS WHEN PENETRTING FIRE-RTED WLLS ND/OR EILINGS.. REFER TO THE FSNSEL INSTLLTION INSTRUTIONS FOR DDITIONL REQUIREMENTS. NOTE: Every effort has been made to ssure the accuracy of this information. Dura-Vent cannot guarantee ccuracy and will not be held liable for Errors or omissions. 4 NOTES:. LL WORKMNSHIP MUST MEET ND/OR EXEED LL JURISDITIONL REQUIREMENTS.. INSTLL WLL RKET EVERY TWELVE () FEET OF VERTIL RUN. 4 4 X X 0 X 7.0 X X ITEM REVISION HISTORY ZONE REV DESRIPTION DTE PPROVED DRWN W. YOUNG 9//00 HEKED Q MFG PPROVED QTY 0 USTOMER # PRTS LIST PRT NUMER DESRIPTION 004 FS-E8 00 W FS-SWDW8 09 W-VL8-L W W-VL W W W-VL8-L 000 W W-VL8-L 00 W W FS-DWSW8 009 FSS8 00 FSL9 SIZE THIRD NGLE PROJETION DWG NO SHEET OF USTOM in. length 8 in. length 0 in. length NOTIE: THIS DOUMENT ONTINS PROPRIETRY INFORMTION ND IT SHLL NOT E USED, REPRODUED, OR ITS ONTENTS DISLOSED, IN WHOLE OR IN PRT, WITHOUT THE EXPRESS WRITTEN ONSENT OF PROTEH SYSTEMS DIVISION OF M & G DUR-VENT OMPNY, IN. REV D FasNSeal Special Gas Vent ommercial pplications ommercial projects may require custom parts and unique system designs. DuraVent offers complete project assistance: 0 4 oilers are: erco MK..0 (X) M & G Engineering Services: Personalized system design services offer comprehensive D submittal drawing and complete bills of materials. ustom Parts: If your project requires innovative solutions, contact DuraVent for custom parts that meet your specific project needs. FasNSeal W: FasNSeal W is the ideal choice for commercial applications where there is a need for low clearances to combustibles. Up to Vent Diameters: Many commercial applications require large diameter systems due to the units size and output. Large diameters are available in single and double wall, featuring FasNSeal s triple lipped directional gaskets and built-in locking band which provides a safe and convenient installation. learances hart FasNSeal Rated Operating Temperatures Enclosed Unenclosed Horizontal Vertical Horizontal Vertical F \ 90 0" 0" (anada Only) 00 F / 49 Sides: 8 4 Top: 480 F / 49 ottom: 4 94 F / 90 0" 0" (anada Only) 00 F \ 49 Noncombustible Enclosure 480 F \ 49 FasNSeal W Rated Operating Temperatures Enclosed Unenclosed Horizontal Vertical Horizontal Vertical 94 F (anada Only) 0" 0" 0" 0" F 400 F " 480 F " 4 94 F (anada Only) 0" 0" 0" 0" - 00 F 400 F " 480 F " Rated Operating Temperature of 00 F = Max Flue Gas Temperature of 7 F Rated Operating Temperature of 480 F = Max Flue Gas Temperature of 0 F 7 DuraVent
7 FasNSeal W Special Gas Vent FasNSeal W - Double-Wall Vent Length Used for venting special gas burning ategories II, III and IV appliances. To calculate O.D. add to vent diameter. SIZE ORDER # STOK # W W W W W W W W W W W W W W W W W W " 8 W W W W W W W W W W SIZE ORDER # STOK # 8 W W W W W W W W W W W W W W W W W W W W W W W W W W W DuraVent
8 Special Gas Vent FasNSeal W djustable Vent Length Use to add variable length to your straight length of FasNSeal pipe. dds 4 of length. Requires at least 4 overlap for a secure connection. SIZE ORDER # STOK # SIZE ORDER # STOK # W-VL " W-VL W-VL " W-VL W-VL W-VL W-VL W-VL W-VL W-VL W-VL Elbow Use to go from horizontal to vertical runs or vertical to horizontal runs. Use to turn vent 90. SIZE ORDER # STOK # SIZE ORDER # STOK # W W ½ ¼ 9" W " W ½ 9 /8 W ¾ W ½ 7 ½ W ½ 0 ¼ 4 W ½ 8 7 W / W ½ 8 W ½ 8 ¼ 88 Elbow Use to transition from a vertical to a horizontal run. Facilitates a pitch towards the condensate drain for good condensate management. SIZE ORDER # STOK # W " SIZE ORDER # STOK # W ½ 0 ¼ 4 W ½ W " 4 4 W ½ 8 W " ½ W ½ 7 ½ 7 W /8 8 W ½ 8 ¼ 9" W " 9" 0" W ½ DuraVent 99
9 FasNSeal W Special Gas Vent 4 Elbow Offsets obstructions as needed. llows for better condensate management and less back pressure. SIZE ORDER # STOK # W W /8 W ¼ W W ¾ 8 W /8 8 SIZE ORDER # STOK # 9" W ½ 7 8 0" W W ½ 4 ¼ 4 W ¼ 4 8 W " Elbow Offsets obstructions as needed. llows for better condensate management and less back pressure. SIZE ORDER # STOK # W W W ¼ W ½ 7 W W SIZE ORDER # STOK # 9" W " ½ 0" W ½ ¼ W ½ 4 W ½ ½ W ¾ Elbow Offsets obstructions as needed. llows for better condensate management and less back pressure. SIZE ORDER # STOK # W /8 4 W ½ W /8" 7/8 W ¾" 7/8 7 W /8 8 W /8" SIZE ORDER # STOK # 9" W ¼" 0" W ¼" W ½" 4 W ¾" W /8" 00 DuraVent
10 Special Gas Vent FasNSeal W Standard Tee Use for a 90 offset, to combine connections from two or more appliances into a common vent or as a condensate management point when used in conjunction with drain fitting. ll Standard Tees have completely welded inner walls. SIZE ORDER # STOK # SIZE ORDER # STOK # W-T " W-T W-T " W-T W-T W-T W-T W-T W-T W-T W-T Wide Mouth oot Tee Use to transition from horizontal to vertical with improved flue gas flow with angled gradual transitions. an also be used as a manifold connection to gang boilers into a common vent. ompletely welded inner walls. SIZE ORDER # STOK # SIZE ORDER # STOK # 4 W-WT W-WT W-WT W-WT W-WT " W-WT " W-WT W-WT " " 0 9 0" 4 W-WT " " 9 0" W-WT " " 9 0" Double-Wall Wye Use in place of any DuraVent tee for a 4 angle instead of 90 ; can be used as a manifold connection to gang multiple boilers into a common vent. SIZE ORDER # STOK # W-WYE ½ /8 7 W-WYE / 8 / ½ 8 W-WYE /0 4 9 W-WYE /0 0 7/0 4 / 0 W-WYE / 4 W-WYE W-WYE /0 /8 / W-WYE / 7 / DuraVent 0
11 FasNSeal W Special Gas Vent Double-Wall Increaser Wye Double Wall D 4 D D Use in place of any tee for a 4 angle instead of 90. The branch has a smaller diameter, so it can be used to increase to a larger diameter as a manifold connection to gang multiple boilers into a common vent. Maximum diameter increase is. vailable in custom size combinations. SIZE ORDER # STOK # x 8" W-WYE " 9 4" 8" x 0" W-WYE " 0 8" 8" x " W-WYE " " 4" 8 x 0" W-WYE " 8" 4 8" 8 x " W-WYE " 4" 4 " 8 x 4" W-WYE " 4 4" 4 8" 0 x " W-WYE " " 8" 0 x 4" W-WYE " " 8" 0 x " W-WYE " 8" " x 4" W-WYE " 8" 8" Tee ap Use to cap Standard Tee, ranch Tee or oot Tee. Remove Tee ap to inspect the system; clean out debris. SIZE ORDER # STOK # W-T W-T W-T W-T W-T W-T SIZE ORDER # STOK # 9" W-T " W-T W-T W-T W-T Drain Fitting Use instead of Tee ap to manage condensates at the bottom of a vertical run. For vent systems larger than, use an IPS Drain Fitting. SIZE ORDER # STOK # W-DF W-DF W-DF DuraVent
12 Special Gas Vent FasNSeal W IPS Drain Fitting Use to connect iron drain pipe to flow acidic condensates to a neutralization tank before disposal. Uses NPT thread. SIZE ORDER # STOK # W-IPSDF " 4" W-IPSDF W-IPSDF W-IPSDF " W-IPSDF W-IPSDF SIZE ORDER # STOK # 9 W-IPSDF W-IPSDF W-IPSDF " W-IPSDF " W-IPSDF Wall Thimble w/ VL Use for through-the-wall termination. Fits between standard wall studs. - diameters accommodates wall thickness of 4 4 to 8. diameters accommodate wall thickness of 4 to. VL pipe allows for adjustability in length variance. SIZE ORDER # STOK # W-WT W-WT W-WT W-WT " W-WT W-WT W-WT W-WT W-WT " W-WT " W-WT DuraVent 0
13 FasNSeal W Special Gas Vent Wall Thimble Sleeve When installing FasNSeal W with this component use larger diameter, (e.g. 0 vent system, use size). SIZE ORDER # STOK # FSWTE FSWTE FSWTE FSWTE " FSWTE FSWTE FSWTE FSWTE FSWTE " FSWTE " FSWTE Support lamp Use to support vertical and horizontal runs. Recommended every 0 in the vertical run. Use additional Support lamps as needed. When installing FasNSeal W with this component use larger diameter, (e.g. 0 vent system, use size). SIZE ORDER # STOK # 4" FSL SIZE ORDER # STOK # 0 FSL FSL 8000 FSL FSL " FSL " FSL " FSL FSL FSL DuraVent
14 Special Gas Vent FasNSeal W Rain ap Use where pipe terminates above the roof line. When terminating larger than vent diameter use a Termination one. " - 9" 0" - " SIZE ORDER # STOK # W-R W-R W-R W-R " W-R W-R W-R W-R ¾ 8 W-R W-R ½ W-R ¾ Termination one Use for vertical termination. reates static back pressure to adjust harmonics. Venturi effect increases velocity of flue gases. Reduced opening provides for a smaller cross section to deter rain from entering the system. vailable in custom size combinations. SIZE ORDER # STOK # 8 x W-N x W-N Stepped Increaser Use to increase vent diameter when space constraints are an issue. vailable in custom size combinations. SIZE ORDER # STOK # 4 x W-4I " 8 x 9 W-89I DuraVent 0
15 FasNSeal W Special Gas Vent Tapered Increaser Use to increase vent diameter. reates a smooth transition for an undisruptive flow. dditional sizes available up to a maximum of 0" diameter change. SIZE ORDER # STOK # x 4 W-004TI x W-00TI Eccentric Increaser Use to transition to a larger diameter pipe. djusts the systems center point to offset from obstructions. ids in reducing formation of condensates on horizontal runs. FasNSeal W has a 0 max change in diameter. dditional sizes available up to a maximum of 0" diameter change. SIZE ORDER # STOK # 8 x 0 W-080E Stepped Reducer Use to reduce vent diameter when space constraints are an issue. vailable in custom size combinations. SIZE ORDER # STOK # 7 x W-7R " " x 0 W-0R Tapered Reducer 4 Use to reduce vent diameter. reates a smooth transition for an undisruptive flow. FasNSeal W has a 0 max change in diameter. dditional sizes available up to a maximum of 0" diameter change. SIZE ORDER # STOK # 8 x 7 W-0807TR " x 7 W-007TR DuraVent PRODUT DESRIPTION FasNSeal SSEMLY DRWING 0" TO 8" TPERED
16 Special Gas Vent FasNSeal W Single-Wall dapter Use to transition from double-wall pipe to single-wall pipe. To transition from single-wall to double-wall, please reference double-wall adapter available in single-wall FasNSeal section. SIZE ORDER # STOK # FS-DWSW FS-DWSW FS-DWSW FS-DWSW " FS-DWSW FS-DWSW SIZE ORDER # STOK # 9 FS-DWSW FS-DWSW FS-DWSW " FS-DWSW " FS-DWSW Firestop/Flat Flashing Use when penetrating floor levels. When installing double-wall with this component use larger diameter, (e.g. 0 vent system, use size). SIZE ORDER # STOK # SIZE ORDER # STOK # 4 FSFS FSFS FSFS " FSFS FSFS FSFS FSFS FSFS FSFS FSFS " FSFS FSFS " FSFS Wall racket Use to support vent pipe or tee sections. Provides proper clearance to combustibles. When installing FasNSeal W with this component use larger diameter, (e.g. 0 vent system, use size). SIZE ORDER # STOK # SIZE ORDER # STOK # 4" FSW FSW FSW FSW FSW FSW " FSW " FSW FSW FSW FSW " FSW FSW DuraVent 07
17 FasNSeal W Special Gas Vent ird Screen Use for and 4 standard through-the-wall terminations. heck installation instructions for restrictions on horizontal terminations, such as minimum distance from windows and doors. SIZE ORDER # STOK # " FSS " FSS ird Screen Use for to through-the-wall termination. Deters rain and other elements from entering the vent system. heck installation instructions for restrictions on horizontal terminations, such as minimum distance from windows and doors. SIZE ORDER # STOK # FSS FSS " FSS FSS FSS FSS FSS " FSS " FSS 8000 Termination Tee Use for standard and high-wind through-the-wall terminations. heck installation instructions for restrictions on horizontal terminations, such as minimum distance from windows and doors. SIZE ORDER # STOK # FSTT FSTT FSTT FSTT Termination ox Use for horizontal through-the-wall terminations. heck installation instructions for restrictions on horizontal terminations, such as minimum distance from windows and doors. SIZE ORDER # STOK # " FST " FST DuraVent
18 Special Gas Vent FasNSeal W Storm ollar Use to create a weather tight seal between the pipe and flashing. When installing FasNSeal W with this component use larger diameter, (e.g. 0 vent system, use size). SIZE ORDER # STOK # 4 FS FS FS " FS FS SIZE ORDER # STOK # 9 FS FS FS " FS " FS Variable Pitch Roof Flashing Use to create a weather-tight penetration where the vent pipe passes through the roof. Storm ollar required. When ordering Flashings for FasNSeal W product the flashing diameter and vent diameter are the same. ie. W-0 requires a FSVPF0. ccommodates flat to 9/ roof pitch. SIZE ORDER # STOK # 4 FSVPF FSVPF FSVPF " FSVPF FSVPF SIZE ORDER # STOK # 9 FSVPF FSVPF FSVPF " FSVPF " FSVPF Tall one Flashing Use to create a weather-tight penetration where the vent pipe passes through a flat roof. Storm ollar required. When ordering Flashings for FasNSeal W product the flashing diameter and vent diameter are the same. ie. W-0 requires a FSVPF0. SIZE ORDER # STOK # FSF " FSF " FSF " FSF " FSF " FSF SIZE ORDER # STOK # 9" FSF " FSF " FSF " FSF " FSF DuraVent 09
FasNSeal 80/90 FasNSeal & FasNSeal W2 FasNSeal Flex
FasNSeal 80/90 FasNSeal & FasNSeal W FasNSeal Flex FSNSEL 80/90 hange to High Efficiency? Utilize Your Existing ommon Vent! FasNSeal 80/90 ap LISTINGS Storm ollar Flashing DuraVent s FNS 80/90 ombination
More informationCVS. Venting System for Category II, III, and IV gas appliances. Listed to UL-1738 and ULC S636.
VS Venting System for ategory II, III, and IV gas appliances. Listed to UL-1738 and UL S636. PelletVent venting system. Listed to UL 641, UL S609, and UL/ORD 441. Unitized venting system for DirectVent
More informationAL29-4C (UNS S44735) Direct Vent System for Category II, III & IV Heating Equipment 3 through 16
L29- (UNS S7) Direct Vent System for ategory II, III & IV Heating Equipment through Set the standard as the first vent system with a built-in gasket and locking band, designed for high efficiency gas heaters
More informationPelletVent Pro. Biofuel venting system. UL 641, ULC S609, and ULC/ORD C441.
PelletVent Pro iofuel venting system. UL 641, ULC S609, and ULC/ORD C441. Specifications pplications PelletVent Pro is a venting system designed for stoves and inserts that use wood pellets and oil fuel.
More informationTechnical and Dimensional Data. Saf-T Vent SC Plus
Technical and Dimensional Data Saf-T Vent S Plus 3"/5" & 4"/7" oncentric Reduced learance Double Wall for Special Gas Vent and/or Sealed ombustion Systems lso For Venting Listed Gas or Oil Fired ppliances
More informationDirectVent Pro CVS. Unitized, co-axial venting system for direct vent gas or propane stoves, and fireplaces.
DirectVent Pro Unitized, co-axial venting system for direct vent gas or propane stoves, and fireplaces. VS Venting System for ategory II, III, and IV gas appliances. Listed to UL-1738 and UL S636. Specifications
More informationPelletVent Multi-fuel venting system. UL 641.
PelletVent Multi-fuel venting system. UL 641. Specifications Applications PelletVent is designed for venting of pellet stoves and inserts. Consult appliance manual for additonal requirements. Materials
More informationDURAVENT POLYPRO VENTING PRODUCTS
DURVENT POLYPRO VENTING PRODUCTS INDEX FLEX VENTING SYSTEM DPTER KIT... 14-11 -VENT RETROFIT DPTERS... 14-10 CHIMNEY CP... 14-10 CHIMNEY LINING KIT... 14-10 CHIMNEY SUPPORT... 14-11 COUPLER DPTER... 14-12
More informationULC S636 System. PolyPro. PolyPro Flex. Terminations
PolyPro Polypropylene venting products for high-efficiency condensing appliance installations. Chloride free, environmentally safe. Listed to ULC-S636. Specifications pplications PolyPro is a polypropylene
More informationDuraPlus HTC. All-fuel, double-wall chimney system. ULC S629.
DuraPlus HTC ll-fuel, double-wall chimney system. ULC S629. Specifications pplications DuraPlus HTC is a double-wall, all-fuel chimney system for both the U.S. and Canada for use with wood stoves; fireplaces;
More informationFasNSeal. M&G DuraVent s Single-Wall Special Gas Vent Commerical Venting
M&G DuraVent s Single-Wall Special Gas Vent FasNSeal 3-4 ommerical Venting Set the standard as the first vent system with a built-in gasket and locking band, designed for high efficiency gas heaters where
More informationNovaVent. Dimensional Data
NovaVent Dimensional Data NovaVent The new vent system designed and engineered for today s competitive sales environment. NovaVent NovaVent is designed and engineered to meet the requirements of gas-fired
More informationAll-fuel, double-wall chimney system. UL 103 HT, UL 103, and ULC S604.
DuraTech ll-fuel, double-wall chimney system. UL 103 HT, UL 103, and UL S60. DuraTech ll-fuel himney Typical Installations For 5-2 DuraTech *updated typicals* 6 1 19 8 16 1 19 5 1 8 1 6 2 Installation
More informationANY EVERY ONE ONE No matter what the venting application, from gas fired to oil to all fuel heating equipment, Z-FLEX is your one-stop solution.
NY EVERY ONE ONE No matter what the venting application, from gas fired to oil to all fuel heating equipment, Z-FLEX is your one-stop solution. Specialists in Flexible Z-FLEX has been providing flexible
More informationPelletVent Pro horizontal Kit. PelletVent Pro. PelletVent Pro Vertical Kit - Cathedral. PelletVent Pro Pellet Chimney
PelletVent Pro horizontal Kit Kit includes: Round horizontal Cap, Wall Thimble, and Appliance Adapter. Pipe lengths not included. 4 Kit includes a 3-4 Appliance Adapter/Increaser, painted black. 3 3PVP-KHA
More informationFLANGED CORR/GUARD CORR/GUARD INSTALLATION INSTRUCTIONS
CORR/GUARD INSTALLATION INSTRUCTIONS This symbol on the nameplate means this product is listed by Underwriters Laboratories Inc. Tested to UL1738 / CAN / ULCS636-08 Listing No. MH26687 Testing No. 11EN
More informationPelletVent Pro. Biofuel venting system. UL 641, ULC S609, and ULC/ORD C441.
PelletVent Pro iofuel venting system. UL 641, ULC S609, and ULC/ORD C441. Specifications Applications PelletVent Pro is a venting system designed for stoves and inserts that use wood pellets and oil fuel.
More informationCorr/Guard PRESSURE RATED VENTING SYSTEM IMPORTANT: DO NOT INSTALL WITHOUT FIRST READING THESE INSTRUCTIONS VERY CAREFULLY.
CORR/GUARD INSTALLATION INSTRUCTIONS This symbol on the nameplate means this product is listed by Underwriters Laboratories Inc. Tested to UL1738 / CAN / ULCS636-1995 Listing No. MH26687 Testing No. 11EN
More informationTwin wall Air Gap Insulated Zalutite & Aluminium Commercial Gas Vent Chimney System
Q Twin wall ir Gap Insulated Zalutite & luminium ommercial Gas Vent himney System Designed for Individual and Modular Natural Draught Gravity Flow himney pplications PRODUT INFORMTION INTRODUTION Q is
More informationCombustion Air System DVL. DuraBlack. Triple-wall stovepipe system designed to provide air for combustion through its components. ULC S641.
Combustion ir System Triple-wall stovepipe system designed to provide air for combustion through its components. ULC S641. DVL Double-wall interior close clearance stovepipe for connecting woodstoves to
More informationSMALL DIAMETER CORR/GUARD & SLEEVED CORR/GUARD
CORR/GUARD INSTALLATION INSTRUCTIONS This symbol on the nameplate means this product is listed by Underwriters Laboratories Inc. Tested to UL1738 / CAN / ULCS636-08 Listing No. MH26687 Testing No. 11EN
More informationPelletVent Pro. Biofuel venting system. UL 641, ULC S609, and ULC/ORD C441.
PelletVent Pro iofuel venting system. UL 641, ULC S609, and ULC/ORD C441. Specifications Applications PelletVent Pro is a venting system designed for stoves and inserts that use wood pellets and oil fuel.
More informationSUBMITTAL RECORD. ULC S636 - PolyPro. Single-Wall Double-Wall Concentric Flex
SUMITTL RECORD ULC S636 - PolyPro Polypropylene vent pipe for use with NSI Category II and IV gas-burning appliances, including high efficiency water heaters, condensing boilers and warm air furnaces.
More informationBring In the Fresh Air
ring In the Fresh Air ombustion Air System For DuraTech, DuraPlus HT and PelletVent Pro DuraVent s new, exclusive, patentpending DuraPro ombustion Air System Wall Thimble and eiling Support oxes is the
More informationCombustion Air System DVL. DuraBlack. Triple-wall stovepipe system designed to provide air for combustion through its components. ULC S641.
System Triple-wall stovepipe system designed to provide air for combustion through its components. ULC S641. DVL Double-wall interior close clearance stovepipe for connecting woodstoves to chimney. ULC
More informationEasy to assemble. Silicone gasket sealed. Laser-welded seams. Smooth joint connections. 360 Lock-Tab secure rotation
Easy to assemble Silicone gasket sealed Laser-welded seams Smooth joint connections 360 Lock-Tab secure rotation Evenly spaced inner and outer pipes Continuous column of air insulation Ultimate Pellet
More informationBy Bernard Dalsin Mfg. Co. Installation and Operating Instructions Read these instructions and keep them for future reference
By Bernard Dalsin Mfg. Co. 5205 208 th St Farmington MN 55024 L-VENT TYPE 3 "and 4" Factory-built venting system for wood pellet, corn or biomass and low-temperature gas or liquid fuel appliances Installation
More informationMitchell Metal Products, Inc.
Mitchell Metal Products, Inc. Mitchell Metal Products Kosciusko, Mississippi Established 1924 H i g h w a y 1 2 E P. O. B o x 7 8 9 K o s c i u s k o, M S 3 9 0 9 0 O f f i c e : 6 6 2-2 8 9-7 11 0 o r
More informationC. Manufactured double wall chimneys for fuel fired equipment. D. NFPA 54 - National Fuel Gas Code; National Fire Protection Association; 2009.
SECTION 235100 - BREECHINGS, CHIMNEYS, AND STACKS PART 1 GENERAL 1.1 SECTION INCLUDES A. Fabricated breechings. B. Manufactured chimneys for gas fired equipment. C. Manufactured double wall chimneys for
More informationflexible venting simply perfect cost efficient convenient durable Est FREEDOM VENTING FLEX
flexible venting simply perfect cost efficient convenient durable Est. 1990 FLEX FREEDOM VENTING Introduction Freedom Flex Venting systems are top of the line when it comes to materials, cost efficiency
More informationVENT SYSTEM COMPONENTS
Chimney Liner Kits Chimney Liners - All Fuel Chimney Liners - Gas Made from durable, corrosion-resistant type 316 stainless steel Designed to be used with wood, oil, coal and non-condensing gas-fired appliances
More informationPellet Stove. Flex Pipe. Appliance Connector
Installation Instructions & Owners Maintenance Guide DT-M Direct-Temp for Multi Fuel L-Vent / Vent System for Pellet, Corn and other Bio-Fuel Burning Appliances Introduction Direct-Temp for Multi-Fuel
More informationTYPE L VENT / VENT SYSTEM FOR PELLET BURNING APPLIANCES
INSTALLATION INSTRUCTIONS & MAINTENANCE GUIDE TYPE L VENT / VENT SYSTEM FOR PELLET BURNING APPLIANCES LISTED TO ULC-S609 & UL641 A MAJOR CAUSE OF VENT RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES
More informationZ-VENT MODEL SVE SERIES III INSTALLATION AND MAINTENANCE INSTRUCTIONS
Z-VENT MODEL SVE SERIES III INSTALLATION AND MAINTENANCE INSTRUCTIONS 3 & 4 SPECIAL STAINLESS STEEL VENTING SYSTEM FOR GAS BURNING APPLIANCES CATEGORY I, II, III, & IV TESTED AND LISTED BY UNDERWRITERS
More informationPolyPro: For Venting Condensing Appliances Environmentally Safe Alternative Lower Over-All Cost Than PVC Engineered Terminations Fast, Easy To Install
PolyPro : For Venting Condensing Appliances Environmentally Safe Alternative Lower Over-All Cost Than PVC Engineered Terminations Fast, Easy To Install Being Green, Being Responsible. DuraVent looks for
More informationFasNSeal. Installation Instructions
Installation Instructions FasNSeal & FasNSeal W2 Single-wall and Double-wall special gas vent FasNSeal Flex Flexible chimney liner for special gas vent for Category II, III, and IV appliances FasNSeal
More informationModel IVSI Positive Pressure Venting Systems
C O M M E R C I A L A N D I N D U S T R I A L V E N T I N G Model IVSI Positive Pressure Venting Systems Ideal for discharging exhaust gases and fumes from boilers, heaters, ovens, engines, turbines and
More informationVenting System For Pellet and Corn Stoves. PelletVent Pro. C o m p l e t e V e n t i n g S o l u t i o n s f o r t h e H e a r t h I n d u s t r y
Venting System For Pellet and Corn Stoves PelletVent Pro C o m p l e t e V e n t i n g S o l u t i o n s f o r t h e H e a r t h I n d u s t r y ii PelletVent Pro For Stoves Burning Pellets & Corn Simpson
More information2012 INTERNATIONAL FUEL GAS CODE VENTS
2012 INTERNATIONAL FUEL GAS CODE SECTION 502 (IFGC) VENTS 502.1 General. All vents, except as provided in Section 503.7, shall be listed and labeled. Type B and BW vents shall be tested in accordance with
More informationGAS FIRED BOILERS FOR FORCED HOT WATER VENTING ADDENDUM. ECR International Ltd. - Olsen Division P.O. Box 900 Wallaceburg, Ont.
ODV-B GAS FIRED BOILERS FOR FORCED HOT WATER VENTING ADDENDUM ECR International Ltd. - Olsen Division P.O. Box 900 Wallaceburg, Ont. N8A5E5 TABLE OF CONTENTS HORIZONTAL PIPING... PAGES 1-10 WARNINGS...
More information5"x 8" DIRECT VENT INSTALLATION INSTRUCTIONS FOR DECORATIVE GAS APPLIANCES AND DIRECT VENT HEATERS APPLICATION
5"x 8" DIRECT VENT INSTALLATION INSTRUCTIONS FOR DECORATIVE GAS APPLIANCES AND DIRECT VENT HEATERS APPLICATION These instructions apply to the Simpson Dura-Vent 5"x 8" Direct Vent System. This venting
More informationGWS. Venting Manual. Gas-Fired Water Boilers. Hazard definitions. Contents. Venting method definitions
GWS Gas-Fired Water Boilers Venting Manual Hazard definitions Contents Page Hazards that will cause severe personal injury, death or substantial property damage. Hazards that can cause severe personal
More informationInstallation Instructions
Installation Instructions Type B Gas Vent Model E/R 3" 8" ECCO TYPE B GAS VENT AND ACCESSORIES ARE FOR USE ONLY WITH LISTED CATEGORY 1 GAS-FIRED APPLIANCES OR APPLIANCES LISTED FOR USE WITH TYPE B GAS
More informationInstallation and Maintenance Instructions
Commercial & Industrial Positive Pressure or Condensing AL 29-4C Stainless Steel High Challenge Special Gas Vent Also for Natural Draft Appliances 3",4",5",6",7",8",9",10" and 12" Diameter Special Gas
More informationDirect Vent System. for PELLET STOVES FEATURES. Includes all Selkirk Model VP Pellet Pipe and Direct-Temp components needed to complete a system
CTLOG Direct Vent System for PELLET STOVES Includes all Selkirk Model VP Pellet Pipe and Direct-Temp components needed to complete a system Direct-Temp for pellet stoves is the revolutionary, high-performance
More informationCHIMNEYS AND VENTS CHAPTER 8
CHAPTER 8 CHIMNEYS AND VENTS SECTION 801 GENERAL 801.1 Scope. This chapter shall govern the installation, maintenance, repair and approval of factory-built chimneys, chimney liners, vents and connectors.
More informationInstallation & Maintenance Instructions
Installation & Maintenance Instructions Listed & Tested to UL641, ULC-S609, ULC/ORD C441 AMERIVENT Model PVP Pellet Pipe Plus Vent Connector for Pellet-Fuel Appliances and Other Low-Temperature Applications
More informationType B Gas Vent. Installation Instructions
Installation Instructions Round and Oval Type B GasVent Systems for use with natural as or liquid propane category I and draft hood equipped appliances and appliances listed to use Type B Gas Vent. Type
More informationSL-VENT (oil and gas vent) For use with oil or gas fired appliances. Listed to ULC-609 and UL-641. Available in 5, 6, 7 and 8 I. D.
Typical Installations 0 8 9 Vertical Installation. Vertical Termination ap. Storm ollar. Flashing. Roof Support. Length. ttic Radiation Shield. Firestop 8. ecorative lack Plate 9. Length (lack) 0. Insulation
More informationVenting of Gas Fired Equipment RV
PLEASE DO NOT BOOKMARK ANY ANYTIMECE WEBPAGES! Our system will remember the last page you viewed when logging out and back in but please DO NOT exit out when taking a test. Your place will NOT be saved.
More informationBDM Direct Vent systems are for use with direct vent gas fired appliances.
INSTALLATION INSTRUCTIONS Pro-Form DIRECT VENT SYSTEM Tested to ANSI Z21.88-2009 /CSA 2.33-2009 REPORT # 369-P-02b-6.5 Read through all venting and appliance instructions before beginning your installation.
More informationThe intelligent alternative for flue gas venting systems
The intelligent alternative for flue gas venting systems FIRST LISTED InnoFlue is the first polymeric vent system tested and listed to ULC-S636 and UL-1738 in North America Intelligent for a good reason
More informationGas Stoves. C34-10 Direct Vent Gas Stove. Side wall E F. Back wall F E. Model C34-NG10 C34-LP10
Back wall Gas Stoves Model C34-NG10 C34-LP10 Fuel Type Natural Gas Propane Minimum Supply Pressure 5.0 W.C. (1.25 kpa) 12.0 W.C. (3.00 kpa) Manifold Pressure - High 3.8 W.C. (0.95 kpa) 11 W.C. (2.74 kpa)
More informationSUBJECT: SELKIRK MODEL DT DIRECT VENT SYSTEM FOR PELLET & CORN FIRED APPLIANCES / TERMINATION CLEARANCES TO OPENINGS IN BUILDINGS
Selkirk LLC Selkirk LLC Research & Development State Route 93 North & Sutton Road P.O. Box 631 Logan, OH 43138 9/21/2006 TO: Our Valued Customers FROM: Glen Edgar Director R&D SUBJECT: SELKIRK MODEL DT
More informationP P Gas Fireplace. P See Thru
P121-10 - P131-10 Gas Fireplace Model P121/P131-NG10 P121/P131-LP10 Fuel Type Natural Gas Propane Minimum Supply Pressure 5 W.C. (1.25 kpa) 12 W.C. (3.00 kpa) Manifold Pressure - High 3.8 W.C. (0.95 kpa)
More informationCHAPTER 8 CHIMNEYS AND VENTS
CHAPTER 8 CHIMNEYS AND VENTS SECTION 801 GENERAL 801.1 Scope. This chapter shall govern the installation, maintenance, repair and approval of factory-built chimneys, chimney liners, vents and connectors.
More informationINSTALLATION INSTRUCTIONS
ELIMINATOR 36 Wood Burning Fireplace Models: 36E Non-Circulating (Smooth Face) I36E Non-Circulating (Smooth Face) Fully Insulated INSTALLATION INSTRUCTIONS SAVE THIS BOOK This book is valuable. In addition
More informationManual Addendum. This Addendum needs to be used in conjunction with the Evergreen Boiler Manual P/N _0518
Manual Addendum This Addendum needs to be used in conjunction with the Evergreen Boiler Manual P/N 550-100-191_0518 ATTENTION to installers and homeowners of Evergreen boilers. KEEP THIS ADDENDUM WITH
More informationGas Stoves. H15-10 Direct Vent Gas Stove. Model H15-NG10 H15-LP10. Approved Venting Systems
H15-10 Direct Vent Gas Stove Model H15-NG10 H15-LP10 Fuel Type Natural Gas Propane Minimum Supply Pressure 5.0 W.C. (1.25 kpa) 12.0 W.C. (3.00 kpa) Manifold Pressure - High 3.8 W.C. (0.95 kpa) 11 W.C.
More informationThat s The Metal-Fab Way Experience The Difference
1 Faster. Safer. etter. Metal-Fab provides complete and comprehensive venting solutions to the HV, hearth and plumbing markets. Founded in 1959, on the premise that better products and services would be
More informationVenting Supplement. Direct Vent Through-Roof or Through-Unused-Chimney. Water Boiler Series 3 & 4
GOLD GV Water Boiler Series 3 & 4 Venting Supplement Direct Vent Through-Roof or Through-Unused-Chimney For use with Weil-McLain Through-Roof or Through- Unused-Chimney Termination Kit Kit part # 382-200-435
More informationAdvanced Venting Systems
Advanced Venting Systems 1 Z-Vent Special Gas Vent 3 Flexible Vent Connector Systems 5 Aluminium Chimney Liner System 7 Stainless Steel Chimney Liner System 9 Oval Liner System / Advancing the Industry
More informationDirect Exhaust Venting Kit Instructions
CONDENSING GAS BOILER 220/299/300/399 Direct Exhaust Venting Kit Instructions Evergreen 220/299/300/399 Kit part number 383-500-769 STOP! Read before proceeding Hazard definitions The following defined
More informationInstallation and Maintenance Instructions
Installation and Maintenance Instructions Saf-T Vent Model EZ Seal and Model GC Single Wall AL 29-4C Stainless Steel Gas Vent Connector Chimney Liner & Special Gas Vent (USA) / Type BH Vent Class I/II
More informationInstallation and Maintenance Instructions
Installation and Maintenance Instructions Saf-T Vent Model EZ Seal Single Wall AL 29-4C Stainless Steel Gas Vent Connector Chimney Liner & Special Gas Vent (USA) / Type BH Vent Class I/II (Canada) For
More informationINSTALLATION OF VENTING SYSTEM COMPONENTS WARNING
INSTALLATION OF VENTING SYSTEM COMPONENTS WARNING When installing the EVERHOT IGI model series direct vent water heaters, use only EVERHOT vent/air intake system kits and components. Installation and service
More informationEXCEL. ULTRABlack THE MOST DURABLE, EASIEST TO INSTALL RESIDENTIAL CHIMNEY SYSTEM YOU CAN BUY NEVER EVER BUY ANOTHER STOVE PIPE
THE MOST DURABLE, EASIEST TO INSTALL RESIDENTIAL CHIMNEY SYSTEM YOU CAN BUY ULTRABlack NEVER EVER BUY ANOTHER STOVE PIPE Chimney To determine what parts you need for your woodstove installation, try the
More information200i. Vent/air manual. Installation instructions for vent and air piping. Also read and follow: 200i Boiler manual 200i Control manual
M2i-VAM-2 Cast iron condensing boiler 200i Vent/air manual Installation instructions for vent and air piping Also read and follow: 200i Boiler manual 200i Control manual This manual is intended only for
More informationSubmittal Data Model AM Low Intensity Adaptive Modulating Infrared Heaters
Submittal ata Model M ow Intensity daptive Modulating Infrared Heaters Project Engineer ontractor Model # ate: Submitted by: pproved by: General Specification Fuel Type (heck one) Natural Gas PG Heat Exchanger
More informationVP Pellet Pipe. For pellet burning stoves. FEATURES
CATALOG VP Pellet Pipe For pellet burning stoves. Selkirk gives you the safe, efficient, and cost-effective venting system that's engineered precisely for pellet burning stoves. FEATURES Available in 3"
More informationInstallation and Maintenance Instructions. Double Wall AL 29-4C Stainless Steel Special Gas Vent and Type L Vent
Installation and Maintenance Instructions Saf-T Vent CI Plus Double Wall AL 29-4C Stainless Steel Special Gas Vent and Type L Vent For Venting Commercial & Industrial Appliances Condensing Appliances Category
More informationPelletVent. Factory-Built Chimney Relining. Installation Instructions. PelletVent Pro (PVP)
Installation Instructions PelletVent Pro (PVP) PelletVent Factory-Built Chimney Relining A MAJOR CAUSE OF VENT RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES) TO COMBUSTIBLE MATERIALS.
More informationTwin Wall Installation Instructions And Maintenance Guide
Twin Wall Installation Instructions And Maintenance Guide Please read all instructions before beginning your installation. Failure to install this system in accordance with these instructions will invalidate
More informationInstallation and Maintenance Instructions
Installation and Maintenance Instructions Saf-T Vent Model EZ Seal and Model GC Single Wall AL 29-4C Stainless Steel Gas Vent Connector Chimney Liner & Special Gas Vent (USA) / Type BH Vent Class I/II
More informationCHAPTER 8 CHIMNEYS AND VENTS
CHAPTER 8 CHIMNEYS AND VENTS SECTION 801 GENERAL 801.1 Scope. This chapter shall govern the installation, maintenance, repair and approval of factory-built chimneys, chimney liners, vents and connectors.
More information100% Manufactured in the UK. Nova SM. Twin wall, insulated stainless steel multi-fuel chimney system. Also suitable for fully condensing appliances
100% Manufactured in the UK Nova SM Twin wall, insulated stainless steel multi-fuel chimney system lso suitable for fully condensing appliances The Nova SM chimney system range is specifically designed
More informationSaf-T Vent Model EZ Seal Plus/EZ 316 Single Wall Gas Vent Connector Chimney Liner & Special Gas Vent (USA) / Type BH Vent Class I/II (Canada)
Installation and Maintenance Instructions Saf-T Vent Model EZ Seal Plus/EZ 316 Single Wall Gas Vent Connector Chimney Liner & Special Gas Vent (USA) / Type BH Vent Class I/II (Canada) For Venting Residential,
More informationInstallation and Maintenance Instructions
Installation and Maintenance Instructions Saf-T Vent Model EZ Seal Single Wall AL 29-4C Stainless Steel Gas Vent Connector Chimney Liner & Special Gas Vent (USA) / Type BH Vent Class I/II (Canada) For
More informationSaf-T Vent SC Plus/SC 316
Installation and Maintenance Instructions Saf-T Vent SC Plus/SC 316 Double Wall One Inch Air Space Special Gas Vent For Venting Residential and Light Commercial Appliances Category I,II,III,IV Appliances
More informationINSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT
Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT Read All Instructions Thoroughly Before Beginning Installation WARNING
More informationRead and Save These Instructions All Hoods Must Be Installed By A Qualified Installer
Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS UNDER CABINET HOOD Read All Instructions Thoroughly Before Beginning Installation WARNING
More informationINSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT
Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT Read All Instructions Thoroughly Before Beginning Installation WARNING
More information2220 SE Ninth Avenue 2113 Delta Waters Road Portland OR Medford OR SKU Descrpition List
3" Pipe and Fittings GV36 3"x6" B VENT PIPE $12.44 GV312 3"x12" B VENT PIPE $11.13 GV318 3"x18" B VENT PIPE $14.40 GV324 3"x24" B VENT PIPE $17.89 GV336 3"x36" B VENT PIPE $23.09 GV348 3"x48" B VENT PIPE
More informationINSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT
Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT Read All Instructions Thoroughly Before Beginning Installation WARNING
More informationSecure Seal. Single-Wall, Double-Wall and Double-Wall Insulated Special Gas Vent (US) (Canada)
Secure Seal Single-Wall, Double-Wall and Double-Wall Insulated Special Gas Vent www.securitychimneys.com 800-361-4909 (US) 800-667-3387 (Canada) Secure Seal SS, SSD, SSID, & Flex QUALITY AND DEPENDABILITY
More informationH35 Direct Vent Gas Stove. 17,500 BTU/h (5.13 kw) 34,000 BTU/h (9.97 kw) 15,000 BTU/h (4.39 kw) 28,500 BTU/h (8.35 kw)
H35 Direct Vent Gas Stove Model H35-NG10 H35-LP10 Fuel Type Natural Gas Propane Minimum Supply Pressure 5.0 W.C. (1.25 kpa) 12.0 W.C. (3.00 kpa) Manifold Pressure - High 3.8 W.C. (0.94 kpa) 11 W.C. (2.74
More informationH35 Direct Vent Gas Stove. 17,500 BTU/h (5.13 kw) 34,000 BTU/h (9.97 kw) 15,000 BTU/h (4.39 kw) 28,500 BTU/h (8.35 kw)
H35 Direct Vent Gas Stove Model H35-NG10 H35-LP10 Fuel Type Natural Gas Propane Minimum Supply Pressure 5.0 W.C. (1.25 kpa) 12.0 W.C. (3.00 kpa) Manifold Pressure - High 3.8 W.C. (0.94 kpa) 11 W.C. (2.74
More informationThe Monterey (PENNINSULA) MODEL PN36 3-SIDED, WOOD-BURNING FIREPLACE
The Monterey (PENNINSULA) MODEL PN36 3-SIDED, WOOD-BURNING FIREPLACE INSTALLATION AND OPERATING INSTRUCTIONS SAVE THIS BOOK This book is valuable. In addition to instructing you on how to install and maintain
More informationANY EVERY ONE ONE No matter what the venting application, from gas fired to oil to all fuel heating equipment, Z-FLEX is your one-stop solution.
ANY EVERY ONE ONE No matter what the venting application, from gas fired to oil to all fuel heating equipment, Z-FLEX is your one-stop solution. Specialists in Flexible Z-FLEX has been providing flexible
More informationInstallation Instructions. PolyPro Single-Wall Gas Vent System for Category II & IV Gas-Burning Appliances. PolyPro
Installation Instructions PolyPro Single-Wall Gas Vent System for Category II & IV Gas-Burning Appliances PolyPro A MAJOR CAUSE OF VENT RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES)
More informationINSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT
Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT Read All Instructions Thoroughly Before Beginning Installation WARNING
More informationShasta Vent Inc All-Fuel HT Chimney Installation Instructions
Shasta Vent Inc All-Fuel HT Chimney Installation Instructions August 2015 v1.02 A MAJOR CAUSE OF CHIMNEY RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES) TO COMBUSTIBLE MATERIALS.
More informationSECTION DUCTWORK
PART 1 GENERAL 1.1 REFERENCES SECTION 23 31 00 DUCTWORK A. ASHRAE - Handbook, Duct Design B. ASHRAE - Handbook, Duct Construction C. ASTM A90/A90M - Standard Test Method for Weight (Mass) of Coating on
More informationGOLD GV. Venting Supplement for 3 venting. Water Boiler Series 3 & 4
GOLD GV Water Boiler Series 3 & 4 Venting Supplement for 3 venting Special gas vent system vent and combustion air supplement for 3 diameter venting. The following manufacturers AL29-4C Stainless Steel
More informationCWD Series. Gas-Fired Direct Vent Hot Water Boilers INSTALLATION INSTRUCTIONS These instructions must be affixed on or adjacent to the boiler
D E S I G N E D T O L E A D CWD Series Gas-Fired Direct Vent Hot Water Boilers INSTALLATION INSTRUCTIONS These instructions must be affixed on or adjacent to the boiler Models: CWD060 CWD083 CWD110 CWD138
More informationRead and Save These Instructions All Hoods Must Be Installed By A Qualified Installer
Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT Read All Instructions Thoroughly Before Beginning Installation WARNING
More informationInstallation Instructions. PolyPro Single-Wall Gas Vent System for Category II & IV Gas-Burning Appliances. PolyPro
Installation Instructions PolyPro Single-Wall Gas Vent System for Category II & IV Gas-Burning Appliances PolyPro A MAJOR CAUSE OF VENT RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES)
More informationINS A T LL T A ION, OPER T A ING AND SERVICE INSTRUCTIONS FOR FREEDOM CONDENSING HIGH EFFICIENCY DIRECT VENT GAS - FIRED HOT
INSTALLATION, OPERATING AND SERVICE INSTRUCTIONS FOR FREEDOM CONDENSING HIGH EFFICIENCY DIRECT VENT GAS - FIRED HOT WATER BOILER Warning: Improper installation, adjustment, alteration, service or maintenance
More informationThe Next Generation of Greenfield Connectors. Our flex System is Your Solution for Electrical Runs
1/2 to 2 Solid Steel or luminum The Next Generation of Greenfield onnectors SPE-flex Our flex System is Your Solution for Electrical Runs connectors Since 1946 Straight onnectors for Enclosures or Use
More informationINSTALLATION AND OPERATING INSTRUCTIONS TABLE OF CONTENTS IMPORTANT
C US This manual must be left with owner and should be hung on or adjacent to the boilerfor reference. COMMON VENTING MODELS CHS-300 through CHS-399 INSTALLATION AND OPERATING INSTRUCTIONS TABLE OF CONTENTS
More information