FasNSeal. M&G DuraVent s Single-Wall Special Gas Vent Commerical Venting

Size: px
Start display at page:

Download "FasNSeal. M&G DuraVent s Single-Wall Special Gas Vent Commerical Venting"

Transcription

1 M&G DuraVent s Single-Wall Special Gas Vent FasNSeal 3-4 ommerical Venting Set the standard as the first vent system with a built-in gasket and locking band, designed for high efficiency gas heaters where cool flue gases are vented under pressure.

2 Material Selection and Design FasNSeal is manufactured from L9-4, a superferritic stainless steel designed for extreme resistance to chloride ion pitting, crevice corrosion and stress corrosion cracking, as well as general corrosion in oxidizing and moderately reducing environments. L9-4 is an ideal choice for resisting deleterious effects of corrosive condensates created by partially or fully condensing natural gas and propane fired heating appliances. The anadian Gas Research Institute found that test results proved L9-4 to be one of two most corrosion resistant alloys of twenty candidate stainless steels evaluated for resistance to chloride-induced corrosion in condensing and partially condensing gas-fired appliances. FasNSeal has been tested and is listed by Underwriters Laboratories, Inc. to UL 738 and UL-S FasNSeal pplications FasNSeal is a Special Gas Vent and Gas Vent onnector, made from L9-4 stainless steel and designed for use on natural gas or propane-fired appliances listed as ategory II, III and IV or in anada Type H Gas Vent Systems having a rated operating temperature of 480 degrees F and maximum positive pressure of 6 water column. FasNSeal provides horizontal or vertical venting for high efficiency gas boilers, furnaces, booster heaters, pool heaters, water heaters, unit heaters or tankless water heaters. FasNSeal may also be used as a vent for ategory I, natural gas or propanefired heaters. FasNSeal must be sized according to the heating appliance manufacturers instructions, NFP, NFP 54 and any other relevant local building codes and regulations (see installation instructions for details!). Fully ompatible With Double Wall FasNSeal W Each vent length and component features a built-in mechanical locking band and gasket. Parts are simply pushed together to a stop bead, which renders the joints air and water- tight. y tightening the integrated mechanical locking band, parts are fastened together in seconds. FasNSeal can be taken apart and reassembled in minutes, making inspection, maintenance or rerouting of FasNSeal systems a breeze. Should a part or gasket ever become damaged, replacement takes less than five minutes and the integrity of the system is not compromised! Inner Wall Thickness 3-7 ( 76.mm ).06 (.4mm) 8 - (03.mm ).09 (.5mm) 4-6 (355.6mm ).04 (.6mm) 8" 4" (475.mm mm).04 (.6MM) Outer Wall Thickness 3-6 ( 76.mm - 5.4).06 (.4mm) 7-6 (77.8mm ).04 (.6mm) 8" 4" (475.mm mm).04 (.6MM) djustable vent lengths featured in our Wall Thimbles allow for built-in horizontal adjustability without the need for cutting pipe. Our standard djustable Vent Length allows to of adjustment, making pitching FasNSeal to properly drain condensate simple. onnecting FasNSeal to a heater is done efficiently with one of our many adaptors approved by heating appliance manufacturers. Heating equipment can be fired up immediately upon completing a FasNSeal installation, as no cure time or cleanup is required. PTS listened to the installer and came up with the perfect way to join FasNSeal parts. No cutting, no exterior clamps, no joints to wipe with alcohol, no rings, no tabs, no mess to clean. DuraVent *Sizes 3"-6" are UL Listed.

3 FasNSeal is uilt for Performance Proven since 996, FasNSeal features a smooth weld seam inside and out, which is completely shielded during the TIG welding process. ontamination or molecular changes in the weld seam are avoided; no fillers are used in the welding process. Tube ends are formed under the most stringent quality standards to guarantee a perfect fit every time and to avoid built-in stress points or weak areas. FasNSeal Technical Support Is Second To None Submit your specifications on a submittal request form along with your layout and DuraVent will supply comprehensive submittal drawings and a complete bill of materials within 48 business hours. Unless your specs are changed more than once, this service is provided free of charge. For technical or marketing information visit our website at You can contact our technical department at techsupport@duravent.com or call should you prefer personal technical support. FasNSeal Rated Operating Temperatures 3-4 Enclosed Unenclosed Horizontal Vertical Horizontal Vertical 300 F side 8" 4 top " 480 F bottom 4" F noncombustible F enclosure 3 3 Rated Operating Temperature of 300 F = Max Flue Gas Temperature of 375 F Rated Operating Temperature of 480 F = Max Flue Gas Temperature of 550 F Product Flue Gas Temperature ( F) Skin Temp t Location (Per HeatFab diagram) ( F) mbient D E F FasNSeal FasNSeal W Product Flue Gas Temperature ( F) Skin Temp t Location (Rise)(Per HeatFab diagram) ( F) D E F FasNSeal FasNSeal W Product Flue Gas Temperature ( F) Skin Temp t Location (ssume 75 F mbient) (Per HeatFab diagram) ( F) D E F FasNSeal FasNSeal W DuraVent 3

4 Vent Length Use to vent category II, III and IV appliances. 3 FSVL FSVL FSVL FSVL FSVL FSVL FSVL FSVL FSVL FSVL FSVL FSVL FSVL FSVL FSVL FSVL FSVL FSVL " 8 6 FSVL FSVL FSVL FSVL FSVL FSVL FSVL FSVL FSVL FSVL FSVL FSVL FSVL FSVL FSVL FSVL FSVL FSVL FSVL FSVL FSVL FSVL FSVL FSVL FSVL FSVL FSVL FSVL FSVL FSVL FSVL FSVL FSVL FSVL FSVL FSVL FSVL FSVL FSVL FSVL FSVL FSVL FSVL FSVL FSVL FSVL FSVL FSVL FSVL FSVL FSVL FSVL FSVL FSVL FSVL FSVL FSVL DuraVent

5 djustable Vent Length Use to add length to straight length of FasNSeal pipe. dds 4 of length. Requires at least overlap for a secure connection. vailable in ustom Lengths FSVL FSVL FSVL FSVL FSVL FSVL " FSVL " FSVL FSVL FSVL FSVL FSVL FSVL FSVL FSVL djustable Vent Length Use to facilitate for the pitched required in horizontal runs. vailable in ustom Lengths. 3" FSVL " FSVL " FSVL " FSVL " FSVL " FSVL " FSVL " FSVL " FSVL " FSVL " FSVL FasNSeal Flex Use to vent ategory II,III and IV gas burning appliances. Listed to UL 738. an only be used in vertical or near vertical runs. ustom lengths are available for 3 - diameters. Minimum length of 0 for custom orders. Use with FasNSeal components only. SIZE USTOM 3 3FSFLEX-0 3FSFLEX-5 3FSFLEX-30 3FSFLEX-35 3FSFLEX-50 3FSFLEX-00 3FSFLEX-5 3FSFLEX-00 3FSFLEX-XX 4 4FSFLEX-0 4FSFLEX-5 4FSFLEX-30 4FSFLEX-35 4FSFLEX-50 4FSFLEX-00 4FSFLEX-5 4FSFLEX-00 4FSFLEX-XX 5 5FSFLEX-0 5FSFLEX-5 5FSFLEX-30 5FSFLEX-35 5FSFLEX-50 5FSFLEX-00 5FSFLEX-5 5FSFLEX-00 5FSFLEX-XX 5 55FSFLEX-0 55FSFLEX-5 55FSFLEX-30 55FSFLEX-35 55FSFLEX-50 55FSFLEX-00 55FSFLEX-5 55FSFLEX-00 55FSFLEX-XX 6 6FSFLEX-0 6FSFLEX-5 6FSFLEX-30 6FSFLEX-35 6FSFLEX-50 6FSFLEX-00 6FSFLEX-5 6FSFLEX-00 6FSFLEX-XX 7 7FSFLEX-0 7FSFLEX-5 7FSFLEX-30 7FSFLEX-35 7FSFLEX-50 7FSFLEX-00 7FSFLEX FSFLEX-XX 8 8FSFLEX-0 8FSFLEX-5 8FSFLEX-30 8FSFLEX-35 8FSFLEX-50 8FSFLEX-00 8FSFLEX FSFLEX-XX 9" FSFLEX-XX 0" FSFLEX-XX " FSFLEX-XX DuraVent 5

6 Male Flex dapter Use to connect FasNSeal rigid Vent Pipe to FasNSeal Flex at base of masonry chimney or bottom termination. 3 FSSMM " FSSMM FSSMM " FSSMM FSSMM FSSMM " FSSMM FSSMM FSSMM Female Flex dapter Use to connect FasNSeal Flex to FasNSeal rigid Vent Pipe at the top of the system. Ø Ø 3 FSSMF FSSMF FSSMF FSSMF FSSMF " FSSMF " FSSMF " FSSMF FSSMF Test Port 3 4 LOSED OPENED Use to test for proper appliance operation without penetrating the vent wall. Easy access to perform flue gas analysis. More options available, see Universal dapter w/test Port in FasNSeal ppliance dapter section. 3 FSTP FSTP FSTP FSTP " FSTP FSTP FSTP FSTP FSTP " FSTP " FSTP DuraVent

7 90 Elbow Use to go from horizontal to vertical runs or vertical to horizontal runs. Use to turn vent FSEL FSEL FSEL FSEL FSEL FSEL FSEL FSEL FSEL FSEL FSEL FSEL " FSEL FSEL " FSEL Elbow Use to transition from a vertical to a horizontal run. Stabilizes a pitch towards the condensate drain for good condensate management. 3 FSEL FSEL FSEL FSEL FSEL FSEL " FSEL " FSEL FSEL FSEL FSEL Elbow Offsets obstructions as needed. llows for better condensate management and less back pressure. 3 FSEL FSEL FSEL FSEL FSEL FSEL FSEL FSEL FSEL FSEL FSEL FSEL " FSEL FSEL " FSEL DuraVent 7

8 30 Elbow Offsets obstructions as needed. llows for better condensate management and less back pressure. 3 FSEL " FSEL FSEL " FSEL FSEL FSEL FSEL FSEL FSEL FSEL FSEL Elbow Offsets obstructions as needed. llows for better condensate management and less back pressure. 3 FSEL " FSEL FSEL FSEL " FSEL FSEL FSEL FSEL FSEL FSEL FSEL Wide Mouth oot Tee Use to transition from horizontal to vertical. Provides improved flue gas flow with angled gradual transitions. an also be used as a manifold connection to gang boilers into a common vent. SIZE ORDER # SIZE ORDER # 4" FSWT " 7" 6 9 0" " FSWT " " FSWT " " FSWT " 9 0 6" FSWT " " FSWT " FSWT " " FSWT " FSWT " 9 0 8" FSWT " " FSWT " " FSWT " " FSWT " " FSWT " DuraVent

9 Standard Tee Use for a 90 offset, or to combine connections from two or more appliances into a common vent. an also use as a condensate management point when used in conjunction with drain fitting. ll Standard Tees are completely welded. 3 FST " 4 4 FST FST FST FST FST " FST " FST FST FST FST FST FST FST FST ranch Tee Use as a Tee increaser or as a manifold connection to gang boilers into a common vent. vailable in custom size combinations. 4 x 4 x 3 FST x 5 x 3 FST x 6 x 5 FST oot Tee Use to transition from horizontal to vertical with improved flue gas flow. 4 FST FST FST FST FST FST " FST FST " FST " FST DuraVent 9

10 Single-Wall Wye 45 Use in place of any M&G DuraVent tee for a 45 angle instead of 90 ; can be used as a manifold connection to gang multiple boilers into a common vent. 6 FWYE ½ 3 /0 7 FSWYE /3 8 3/5 3 ½ 8 FSWYE /0 4 9 FSWYE /0 0 7/0 4 /5 0 FSWYE /5 4/5 4 9/0 FSWYE / /5 4" FSWYE /0 6 /0 6 3/5 Tee ap Use to cap Standard Tee, ranch Tee or oot Tee. Remove Tee ap to inspect the system; clean out debris or collected condensate. 3 3 FST FST FST FST FST FST " FST " FST0 300 FST FST FST FST FST FST FST Universal ondensate Drain Use to properly manage corrosive condensates common with high efficiency gas appliances. For best results, install close to the appliance. an be used horizontally, vertically, or any angle in between. 3" FSUD " FSUD FSUD FSUD " FSUD FSUD FSUD FSUD FSUD " FSUD " FSUD DuraVent

11 Drain Fitting Use instead of Tee ap to manage condensates at the bottom of a vertical run. For vent systems larger than 6, use an IPS Drain Fitting. 3 3 FSDF " FSDF FSDF FSDF " FSDF FSDF FSDF FSDF FSDF FSDF FSDF IPS Drain Fitting Use to connect iron drain pipe to flow acidic condensates to a neutralization tank before disposal. Uses NPT thread FSIPSDF " FSIPSDF FSIPSDF FSIPSDF " FSIPSDF FSIPSDF FSIPSDF FSIPSDF FSIPSDF " FSIPSDF " FSIPSDF FSIPSDF FSIPSDF FSIPSDF FSIPSDF Horizontal Drain Fitting *updated photo & drawing* Use to manage condensates in horizontal runs. Optimal when ganging multiple appliances into a common vent. 3" FSHDF " 4" FSHDF /" 5" FSHDF /" 6" FSHDF /" 7" FSHDF /" 8" FSHDF /" 9" FSHDF /" 0" FSHDF /" " FSHDF /" 4" FSHDF /" 6" FSHDF /" DuraVent

12 Horizontal Drip Tee Use to manage condensate in horizontal runs. 3" FSHDT " FSHDT ird Screen Use for 3 and 4 standard through-the-wall terminations. heck installation instructions for restrictions on horizontal terminations, such as minimum distance from windows and doors. 3" FSS " FSS ird Screen Use for 5 to 6 through-the-wall termination. Deters rain and other elements from entering the vent system. heck installation instructions for restrictions on horizontal terminations, such as minimum distance from windows and doors. 5 FSS FSS " FSS FSS FSS FSS FSS " FSS " FSS Termination Tee Use for standard and high-wind through-the-wall terminations. heck installation instructions for restrictions on horizontal terminations, such as minimum distance from windows and doors. 3 FSTT FSTT FSTT FSTT DuraVent

13 Termination ox Use for horizontal through-the-wall terminations. heck installation instructions for restrictions on horizontal terminations, such as minimum distance from windows and doors. Larger sizes available, contact customer service. 3" FST " FST Wall Thimble w/termination Damper 8 MIN 4 4 MX 8 Use for horizontal through-the-wall terminations. heck installation instructions for restrictions on horizontal cap terminations, such as minimum distance from windows and doors. ccommodates wall thickness of 4 4 to 8. Damper prevents backdraft of cold air to appliance. Not a UL Listed component. 3" FSWTT " 4" FSWTT " FSWTT Wall Thimble w/vl *updated dimensions* Use for through-the-wall termination. Fits between standard wall studs. 3-5 diameters accommodates wall thickness of 4 4 to diameters accommodate wall thickness of to. VL pipe allows for adjustability in length variance. 8 MIN MX 3 FSWT FSWT FSWT FSWT " FSWT FSWT FSWT FSWT FSWT " FSWT " 6" FSWT DuraVent 3

14 Wall Pass Through *updated dimensions* Use for through-the-wall termination. Fits between standard wall studs. 3-5 diameters accommodates wall thickness of 4 4 to diameters accommodate wall thickness of to. *MIN 4 4, MX 8 MIN 5 3 4, MX 3" FSWPT " FSWPT FSWPT FSWPT " FSWPT FSWPT FSWPT FSWPT FSWPT " FSWPT " FSWPT Wall Thimble Sleeve Extension Use to add 6 of length to Wall Pass Through and Wall Thimble for thicker walls. 3 FSWTE FSWTE FSWTE FSWTE " FSWTE FSWTE FSWTE FSWTE FSWTE " FSWTE " FSWTE Firestop/Flat Flashing Use when penetrating floor levels. 3 FSFS FSFS FSFS FSFS " FSFS FSFS FSFS FSFS FSFS " FSFS " FSFS FSFS " FSFS " FSFS " FSFS DuraVent

15 Support lamp Use to support vertical and horizontal runs using threaded rod. Recommended every 0 on vertical runs and every 6 in horizontals. Use additional Support lamps as needed. 3 FSL FSL FSL " FSL FSL " FSL FSL " FSL " FSL " FSL FSL " FSL FSL " FSL FSL Wall racket Use to support vent pipe or tee sections. Provides proper clearance to combustibles. 3 FSW FSW FSW FSW " FSW FSW FSW FSW FSW " FSW " FSW djustable Wall racket Use to support vent pipe in lateral and horizontal runs. ssist in achieving proper pitch for condensate management. djusts up to 3. 3 FSW FSW DuraVent 5

16 Rain ap Use to terminate above the roof line. When terminating above vent diameter use a Termination one. 3 FSR FSR FSR FSR " FSR FSR FSR FSR FSR Severe Weather Rain ap Use where high winds and horizontal rain are present. For vertical termination only. 4 FSSWR Termination one *updated stock#* Use for vertical termination. reates static back pressure to adjust harmonics. Venturi effect increases velocity of flue gases. Reduced opening provides for a smaller cross section to deter rain from entering the system. vailable in custom size combinations. 5 x 4 FSN x 0 FSN x FSN x 4 FSN x 6 FSN x 8 FSN x 0 FSN x FSN DuraVent

17 Storm ollar Use to create a weather tight seal between the pipe and flashing. 3 FS FS FS " FS FS " FS FS FS " FS FS FS FS FS FS FS Roof Jack Use as a heat shield within the flashing. Maintains center-line and clearance to combustibles. 3 FSVRJ FSVRJ FSVRJ " FSVRJ FSVRJ FSVRJ " FSVRJ " FSVRJ " FSVRJ " FSVRJ FSVRJ FSVRJ " FSVRJ " FSVRJ FSVRJ Variable Pitch Roof Flashing Use to create a weather-tight penetration where the vent pipe passes through the roof. Roof Jack and Storm ollar required accommodates flat to 9/ roof pitch. 3 FSVPF FSVPF FSVPF FSVPF " FSVPF FSVPF FSVPF FSVPF FSVPF " FSVPF " FSVPF " FSVPF " FSVPF " FSVPF " FSVPF DuraVent 7

18 Tall one Roof Jack *new part* Use as a heat shield within the flashing. Maintains center-line and clearance to combustibles. Use with Tall one Flashings FSF " FSF " FSF " FSF " FSF " FSF " FSF " FSF0 3 " FSF 3 3 4" FSF " FSF6 7 3 Tall one Flashing *new part* Use to create a weather-tight penetration where the vent passes through the roof. Roof Jack and Storm ollar required. 3 FSRJ " 4" FSRJ " 5" FSRJ " 6" FSRJ " 7" FSRJ " 8" FSRJ " 9" FSRJ " 0" FSRJ " " FSRJ " 4" FSRJ " 6" FSRJ " Tapered Increaser Use to increase vent diameter. reates a smooth transition for an undisruptive flow. vailable in custom size combinations. 3 x 4 FS0304TI x 5 FS0405TI Eccentric Increaser Use to transition to a larger diameter pipe. Prevents condensate puddling when used on horizontal runs. ids in reducing formation of condensates. Maximum 0 difference between diameter increase size on both sizes. vailable in custom size combinations. 3 x 4 FS0304EI x 5 FS0405EI DuraVent

19 Stepped Increaser Use to increase vent diameter when space constraints are an issue. vailable in custom size combinations x 4 FS34I x 5 FS45I Tapered Reducer Use to reduce vent diameter. reates a smooth transition for an undisruptive flow. Maximum 0 diameter increase size on both sizes. vailable in custom size combinations. 4 x 3 FS0403TR " x 4 FS0504TR " Stepped Reducer Use to reduce vent diameter when space constraints are an issue. vailable in custom size combinations. 6 4 x 3 FS43R x 4 FS54R Double-Wall dapter Ø Use to transition from a single-wall pipe to double-wall pipe. 3 FS-SWDW FS-SWDW FS-SWDW " FS-SWDW FS-SWDW " FS-SWDW FS-SWDW FS-SWDW " FS-SWDW FS-SWDW FS-SWDW FS-SWDW FS-SWDW FS-SWDW FS-SWDW DuraVent 9

20 Standard Wall Mount Kit Kit includes: Wall Thimble w/termination, djustable 90 Elbow, and Universal ppliance dapter. Use to vent wall mounted boilers or tankless water heaters. Terminates through-the-wall only. vailable in 3, 4 and 5 vent diameters. djust vertically from 6 to and horizontally from 8 to. 3 & 4 compatible with most gas-burning appliances. 5 compatible with tankless. Not a UL Listed component. 3 FSWMK FSWMK " FSWMK Severe Weather Kit Kit includes: Wall Thimble w/termination Tee, djustable 90 Elbow, and Universal ppliance dapter w/ondensate Drain and ack Draft Preventer. Use to vent wall mounted boilers or tankless water heaters. Use in areas of extreme wet and cold weather. Designed to prevent appliance freeze-up while maintaining an obstruction free exhaust. vailable in 4 vent diameters, compatible with most 4 exhaust gas appliances. dd a 90 Elbow and Vent Length on the outside of the house to clear high snow lines. 4 FSSWWMK Variable Pitch Flashing Kit Kit includes: Rain ap, Storm ollar, Roof Jack, and Roof Flashing. (*VPK Kit includes: a Universal ppliance dapter w/ondensate Drain). Use to terminate through-the-roof vent systems. Kit accommodates flat to 9/ roof pitch. 3 FSVPK " FSVPK " FSVPK4* FSVPK FSVPK " FSVPK FSVPK FSVPK FSVPK FSVPK " FSVPK " FSVPK DuraVent

21 90 ird Screen Wall Mount Kit Kit includes: 90 ird Screen Termination, Wall Thimble, djustable 90 Elbow, and Universal ppliance dapter. Use to vent wall mounted boilers or tankless water heaters. 3 kit adjusts vertically from 4 to 9 and horizontally from 9 to 3. 4 kit adjusts vertically from 4 to 8 and horizontally from 9 to 3. ompatible with all Rheem gas appliances. 3 kit requires a FS-RI-4. dapter. 3 FSWMKE FSWMKE eiling Mounted Heater Vent Kit Kit includes Termination Tee, Wall Thimble w/djustable Vent Length, () Vent Lengths, and Universal ppliance dapter. *4 kit includes Universal ppliance dapter with ondensate Drain. Use to vent ceiling mounted heaters, through-the-wall termination only. ompatible with Modine ceiling heaters. 3 FSMK FSMK4 300 Universal oncentric Kit Use for through-the-wall termination with direct vent wall mounted gas appliances. Features an adjustable right and left hand air intake snout and accommodates wall thickness of 0-8. heck installation instructions for restrictions on horizontal termination, such as minimum distance from windows and doors. 4 FSEDVWMT04U FSEDVWMT05U Wall Mount oncentric Kit Use for through-the-wall termination with direct vent wall mounted gas appliances. Features a fixed right or left hand air intake snout and accommodates a maximum of 8 wall thickness. heck installation instructions for restrictions on horizontal termination, such as minimum distance from windows and doors. 4 FSDVWMT0403RH max. 4 FSDVWMT0403LH max. 4 FSDVWMT04RH max. 4 FSDVWMT04LH max DuraVent

22 Remote oncentric Kit Use for through-the-wall termination with direct vent gas appliances located away from the wall. heck installation instructions for restrictions on horizontal termination, such as minimum distance from windows and doors. 3 FSDVWT max. 4 FSDVWT max. 4 FSDVWT max. DuraVent

23 ppliances and dapters Manufacturer erco International Model ppliance dapter enchmark.0 GWS, 3.0 LN FS-E8 K-000 FS-E6 Modulex Series Standard Vent Pipe 4, 6 Termination dapter jax tlas GS Series FS-HF6, 8.O. Smith urkay Genesis Series FS-HF4 a, 5 a Legend 000 Series FS-HF6 a, 7 a ProStar Series FSU4 G/GW 400, FSU6 G/GW FSU0 G/GW 300, FSU G/GW 850, FSU4 G/GW FSU6 G/GW FSU0 G/GW 650, FSU8 TI 705-N FSU4 yclone TH FS-PV3 VW FS-HF6 erco enchmark tlas eacon/morris RU Series FSU4 TU Series FSU4, 5, 6 osch quastar 5 FX FS-LMGD4 a quastar GHW-635-ES Standard Vent Pipe 3 quastar 50SX Standard Vent Pipe 3 quastar 40FX FSU4 quastar 400ES FSU3 quastar 700ES FSU4 GWH 45EF FSU4 radford-white EF Series FS-PV3 uderus G5 Series FSU4 or FSU5 G4X Series FSU5, 6 G4 Series FSU3 G44/37, 44, 53 FSU3 G44/6 FSU4 G4 Series FSU3 G3/90 to G3/60 FS-58-6F G3/00 to G3/80 FS-97-8F S65 Series FS-S7, 8, 0, S735 Series FS-S4 urnham Independence PV FS-HF3 b FS-PV3 Minute Man II FS-HF3 b FS-PV3 urnham Revolution FS-HF3 b FS-PV3 Revolution II FS-HF3 b FS-PV3 Series PV FS-HF3 b FS-PV3 Spirit FS-HF3 b FS-PV3 PVG/SG Series FS-HF3 b, 4 b V Series FSU8, 0,, 4, 6 amus oiler MicoFlame Series I FSU3, 4, 5, 6 MicoFlame Series II FSU8, 0, MicoFlame Grande Series FSU, 4 DynaFlame Series FSU6, 8, 0,, 4 arel Humidifier UG 80 FSU5 leaver rooks MF Series FS-MF6, 8, 0, FLX Series FS-FLX0,, 6 F FSU8 F FSU0 F FSU6 olumbia Patriot Series-Direct Vent FS-UT4 rown oiler o. ali WF-06, 095, 8, 6 Standard Vent Pipe 3 a FS-M3 a ali WF-95, 9 Standard Vent Pipe 4 a FS-M4 a imini W50, 5 Standard Vent Pipe 3 FS-M3, 4 a a, 4 a abo S-050 thru 50 Standard Vent Pipe 3 a FS-M3 a W 399 std. vent pipe abo S-75, 00 Standard Vent Pipe 3 FS-M3, 4 a a, 4 a abo II WD FS-HF3, 4 Dunkirk XE- thru XE-5 FSMETEK3 FS-M3 a XE-6 thru XE-7 FSMETEK3 Standard Vent Pipe 3 De Dietrich GT334, GT335, GT336 FSU7 GT337, GT338, GT339 FSU8 GT430-8 to GT430-0 FSU0 GT430- to GT430-4 FSU Series 334,335, FSU7 Series 337,338, FSU8 Series 430-, -, -3, FSU Series 430-8, -9, FSU0 Series 30-5,-6, -7, -8, FSU0-30 EO *updated* FS-49-6F -30 EO FS-50-0F Fulton oiler PulsePak PHW Series FS04T.5, FS06T.5 Works Vantage VTG3000 FSU PHW FS-06T DuraVent 3

24 ppliances and dapters Peerless DE Series FS-PS/DE3 a PDE Series FS-PDE3 a PS Series FS-PS/DE3 a PS II Series FS-HF3 PF Series PF-50, PF-80, PF-0, PF-40 *updated* PF-0 *updated* PF-399 *updated* PF850, PF-000 *updated* STD 6 SW Vent or SWDW adaptor Pennco FS Series FSMETEK3 Pentair MiniMax NT T PVI Power VT Series FS-HF4 a Quietside QVM8 Series FSU3 FS-PV3 DPW FS-PV4 DPW FS-PV3 Raypak dvanced Design oiler FSU6 D-500 dvanced Design oiler D-750 thru 50 FSU8, 0, Hi Delta thru 34 FSU4, 5, 6, 8,, 4, 6 MV FSU6 MV 003, 753, 503, FSU8 X-Therm WH-505, FSU8 X-Therm WH FSU6 Pool heater R FSU9 Pool heater R FSU8 Pool heater R FSU7 Pool heater R FSU6 RI Fusion Series FS-HFX *updated* Futera II Series FS-HFX *updated* Futera III Series FS-HFX *updated* Dominator Series FS-HFX *updated* LD Dominator Series FS-HFX *updated* Rheem/Ruud RTG-4PVN (Pronto 4.) FS-RI-4. RTG-74 (Pronto 7.4) FSU4 Slantfin aravan Series FS-HF3 a oncept Series FS-HF3 a FS-NYV3 a Slantfin Prodigy FS-HF3 a Victory VSPH Series FS-HF3 a Victory II Series FS-HF3 a Smith ast Iron GV00 Series FS-SMITH4 Lexington GS0 Series FS-EL3, 4 State Water Heater urora GX Smith ast Iron GT FSU3 StayRite Pool Heater FS-STRITE-4 Takagi T-H FSU4 FS-TT4 T-K FSU4 FS-TT4 T-K FSU4 FS-TT4 T-K3 FSU4 FS-TT4 T-KS FSU4 FS-TT4 T-K Jr. FSU4 FS-TT4 T-KD0 FSU4 FS-TT4 T-M FSU4 FS-TT4 T-M50 FSU5 FS-TT4 Solaris FS-TS6 Thermo- Dynamics LMGD Series FS-LMGD4 a FS- LMGDTERM4 a WL-GS Series T Thermal Evolution Series FS-HF3 a, 4 a, 6 a, 8 a Solutions Triangle Tube Delta Performance FS-TR3 Delta Performance Plus FS-TR3 Solo FS-ULT3 Solo FS-ULT4 Utica US Series Standard Vent Pipe a d DV- Series Standard Vent Pipe a d Vapac GF Series FS-GF3 Viessmann Vitocrossal 300 T-3 Series FSU8, 0, Vitogas 50 EV Series Standard Vent Pipe 3 a FS-M3 a Vitogas 00 GS0 Series FSU8, 9, 0 Vertomat VS-37, 46, 57 T Vitodens W Series FS-V3, 4 W FS-80-3F Wai Wela PH-6IFSN/P FS-RI-4. PH-0-RIFS/N FS-RI-4. PH-8RIFSN/P FSU4 Weben Jarco Vision 3000 Series FS-HF6, 8, 0 a E-Finity T Weil McLain GV ST FS-WEIL-GV3 Gi Series FS-WM-GI3 Gs Series FS-WM-GI3 Gt Series FS-WM-GI3 GV GOLD Series 3 FS-WEIL-GVTEE3 GV GOLD Series 4 FS-WEIL-GVTEE3 Ultra Series FS-ULT3, 4 Williamson Thermoflo GWI Series FS-WM-GI3 a = High-temperature RTV silicone sealant is required. b = an also be vented with FSVL3 (3 ) or FSVL4 (4 ). c = dditional Muffler adapters required. d = an use FSU in place of Standard Vent Length with silicone. 4 DuraVent

25 ustom Design Solutions Engineering Support for ommercial pplications ommercial projects require expert knowledge and a fast, flexible, customer oriented approach. From simple single boiler installations to complex multi-unit common vented, or cascaded projects, M&G DuraVent has the expertise, the product offerings and the tools to help you create the right solution. Where exhaust gases permit a non-metallic venting system, we offer our Green Vent Poly Pro product for commercial installations in 5, 6 and 8 diameters. Listed to UL-S636 and featuring engineered ice-free terminations, quick easy assembly and installation as well as an environmentally friendly material, this is the best product available when plastics are your solution. Expertise Our staff of engineers can work with you through a simple and quick submittal process to provide system sizing, simple layout drawings for quotation purposes, a detailed product listing and quote and fully detailed mechanical drawings should your job require. With many years of expert experience we can deal confidently with your needs no matter what the heating appliance may be. Tools We provide expert sizing for your systems using proprietary tools compliant with SHRE standards and the EN4483 standard. Using a quick sketch layout tool we provide a layout drawing and product detail to support your quote. Where you need further detail, we provide full detailed 3D layouts to support your installation. Engineering Support Second to None quick easy submittal process with a simple dimensioned layout sketch provides you with the detail and the quote you need. Products Our FasNSeal product, both single and double-wall, features: triple lipped gasket. utt-welded smooth seams inside and out. built-in mechanical clamping system at each joint. L9-4 stainless steel alloy. No silicone required. Diameters from 3 to 4 with a full compliment of appliance adapters, adjustable vent lengths, tees, increasers, reducers, tee, terminations and condensate management options to suit any install. ssuring you safe, secure installations without call backs. Start Fax: Make: Model: Job ity & State: Flue ollar Diameter: List all applicable building codes, e.g. State, Local & Other: ppliance dapter (If Known): re appliances set in place? Housekeeping pad: (inches) SINGLE WLL DOULE WLL OTH FLEx 6 Fan ssisted Yes No ITEM LL HORIZONTL RUNS MUST HVE MINIMUN PITH OF 4' PER FOOT TOWRDS THE PPLINE 9 6. REFER TO THE FSNSEL INSTLLTION INSTRUTIONS FOR DDITIONL REQUIREMENTS in [.9 ft] NOTE: Every effort has been made to ssure the accuracy of this information. Dura-Vent cannot guarantee ccuracy and will not be held liable for Errors or omissions. 6 How many appliances: EssEntial information 4.00 in [3.50 ft] EVERY SIX (6) FEET OF HORIZONTL RUN. 4. USE FIRE-RTED FIRESTOPS WHEN PENETRTING FIRE-RTED WLLS ND/OR EILINGS. appliance information If appliances of more than one make/model will be installed, include the required information about each appliance. (Use separate sheet if neccessary). Job Name: Date Request Needed y: ZONE. INSTLL WLL RKET EVERY TWELVE () FEET OF VERTIL RUN. ompany ddress: ontact Person: REVISION HISTORY DESRIPTION REV (6.70") (84.000") (48.000") (6.70") (84.000") (3.000") (90.000") ' 4.70" 7' 0.000" 4' 0.000" ' 4.70" 7' 0.000" '.000" 7' 6.000" V V H V V H H ø8 ø7 ø7 ø8 ø7 ø7 ø7 DTE PPROVED. LL WORKMNSHIP MUST MEET ND/OR EXEED LL JURISDITIONL REQUIREMENTS. D 3. USE NON-OMUSTILE HNGER ompany Name: Date: Phone: 3 NOTES: Fill out and send to M&G DuraVent, ttn: Sales Department at sales@duravent.com or (fax) to request a quote, bill of material and/or submittal drawing for a FasNSeal Venting System. To help us provide you with the best and most timely service, make sure all sections of this worksheet have been completed. ll requests will be placed in a queue and given an estimated competion date QTY PRT NUMER PRTS LIST DESRIPTION FSVL06 FSTP06 FS-SWDW6 W-3606 W-VL6 W-9006 W-406 W-WT6 W-06 W-606 FSS6 FSL7 6" 6" 6" 6" 6" 6" 6" 6" 6" 6" 6" 7" D TITLE Dia " Vent Length Dia Test Port S.W. to D.W. adapter Dia 36" Vent Length Double Wall Dia VL Double Wall Dia 90 Deg Elb Double Wall Dia 4" Vent Length Double Wall Dia. D.W. Wall thimble Dia " Vent Length Double Wall Dia 6" Vent Length Double Wall ird screen term. lamp pair 90. in [7.5 ft] Draft Inducer Yes No in [4.00 ft] If yes: MFR.: Model: FM: terminations To provide the fastest service, please provide as many details as possible. service request Revision of Existing Design Layout. Quick Quote (Layout Drawings Not Included - 4 business hours). Layout Drawing & ill of Materials (Within 48 business hours). Sizing (Fill out required info below). sketch/drawing Please provide a sketch with centerline dimensions showing the desired layout. *(Mechanical room drawings without dimensions will NOT E EPTED). Indicate diameters on common vent systems. Include elevation and plan views as required. If possible, identify critical dimensions and/or tolerances. sizing check ltitude: (ft.) omputer ided Vent Diagram Finish Design and Quote Request Submittal Form Vent Diameter(s) (inches): M&G DuraVent Technical and Engineering Support FX engineering@duravent.com Exhaust % O: Smoke Temp.: ( F) Exhaust Pressure: ( W..) Horizontal & Vertical Dimensions of runs: ( ttach Sketch ) TU in: TU out: Roof/Wall/eiling made of combustible material? Yes No Firestops? Yes No 5 Roof/Wall Thickness: (inches) 7 urb Height on Roof: (inches) Termination Details: X Rain ap ird Screen Leave Open Termination one Fan by Others 4 mechanical support (please check preference) Vertical Variable Pitch Wall Mounted Flashing racket Tall one Flashing Support lamp DRWN W. YOUNG HEKED oilers are: Patterson-Kelly Mach -900 (X) racket Support lamp Submit w w w.d uravent.com 6 / fax NY fax L8 Submit the design submittal sheet and either a mechanical drawing OR a hand sketch of the mechanical drawing 4 D a te : / 9 / 0 S c a le : N one Horizontal Wall Mounted revision Submit latest revised layout drawing with desired changes. omments: Reset T ride nt ldg P h in [8.00 ft] 3 Supplied y ustomer Roof Top Roof Pitch 3 NOTIE: THIS DOUMENT ONTINS PROPRIETRY INFORMTION ND IT SHLL NOT E USED, REPRODUED, OR ITS ONTENTS DISLOSED, IN WHOLE OR IN PRT, WITHOUT THE EXPRESS WRITTEN ONSENT OF DURVENT OMPNY, IN. MEMER OF M&G GROUP. TRIDENT LDG. 950 PHSE II /7/0 Q MFG Member of PPROVED USTOMER # SIZE Inventor layout on D software providing the computer aided vent diagram and order of install T ypic a l of P a ge / M&G Group THIRD NGLE PROJETION T:\Wayne Young\66005.dwg D u r a V e nt D ra wn by: W a yne Y oung REV DWG NO SHEET OF P r o je c t N o : System No: Date: S e c ti o n Q ty /9/0 I te m N o P r o je c t N a m e : Location: Layout Title: Trident ldg Ph. N. harleston, S D e s c r i p ti o n W eigh t. F a s N S e a l D ouble W a ll - ' (6.7") length, 8" diameter:. F S -P K 8 8 " D ia da pte r P K Ma c h S e rie s. 6. F S -S W D W 8 8 " D ia S W to W da pte r F S L9 9 " D ia S upport la mp.. W T R 8 " D ia T o 7 " T a pe re d R e duc e r W F a s N S e a l D ouble W a ll - 7 ' (84.00") length, 7" diameter:. W " D ia 3 6 " V e nt L e ngth D ouble W a ll.. F S L8 8 " D ia S upport la mp W - V L 7 7 " D ia dj D ou ble W a ll. 3 F a s N S e a l D ouble W a ll - 4 ' (48.00") length, 7" diameter:. 3 W " D ia 9 0 D e g E lb D ouble W a ll W " D ia 4 " V e nt L e ngth D ouble W a ll W - V L 7 7 " D ia dj D ouble W a ll FS S 7 7 " D ia ird S c re e n W -W T 7 7 " D ia W a ll T himble D ouble W a ll F a s N S e a l D ouble W a ll - ' (6.7") length, 8" diameter:. F S -P K 8 8 " D ia da pte r P K Ma c h S e rie s. 6. F S -S W D W 8 8 " D ia S W to W da pte r F S L9 9 " D ia S upport la mp.. W T R 8 " D ia T o 7 " T a pe re d R e duc e r W F a s N S e a l D ouble W a ll - 7 ' (84.00") length, 7" diameter:. W " D ia 3 6 " V e nt L e ngth D ouble W a ll. 8 " D ia SPurpopjoerct tn laamm pe :. 0 Trident ldg Ph. P.ro j e c t N o : F S L 8. W - V L 7 7 " D ia Location: dj D ouble W a ll 4. 8 N. harleston, S System No: F a s N S elayout a l D oubtitle: le W a ll - ' (3.00") length, 7" diameter: /9/0 Date:. 3 W " D ia 9 0 D e g E lb D ouble W a ll 6. 4 Product(s): W - V L 7 7 " D ia dj D ouble W a ll. 4 F a s N S e a l D ouble W a ll - 7 ' (90.00") length, 7" diameter:.t4y P r o d u c tn o W D e s c r i p ti o n 7 " D ia 9 0 D e g E lb D ouble W a ll 6.Rate 4 Q W eight List. 4 W " D ia 3 6 " V e nt L e ngth D ouble W a ll " D ia da pte r P K Ma c h S e rie s F S L8 8 " D ia S upport la mp " D ia S W to W da pte r W - V L 7 7 " D ia dj D ouble W a ll " D ia S upport la mp FS S 7 7 " D ia ird S c re e n " D ia T o 7 " T a pe re d R e duc e r W W -W T 7 7 " D ia W a ll T himble D ouble W a ll " Dia 36" Vent L e ngth D ouble W a ll , " D ia S upport la mp " D ia dj D ouble W a ll , " D ia 9 0 D e g E lb D ouble W a ll " D ia 4 " V e nt L e ngth D ouble W a ll " D ia ird S c re e n " D ia W a ll T himble D ouble W a ll Total Weight (Lbs): 63. Total List: 6,83. T ota l N e t: Grand Total: ombined ill of Materials X Net , , , 83. 6, DuraVent 5

26 FasNSeal 3-4 ommerical Venting Set the standard as the first vent system with a built-in gasket and locking band, designed for high efficiency gas heaters where cool flue gases are vented under pressure. Information to get the job done right Website efore calling, check the company's literature library to see if your question can be answered there. Publications are available for immediate viewing at lick on the support then 'literature' link to download literature as a pdf that can be saved on your computer or printed out. Working out the details. Every project is different. Each has its own specifications, and constraints. DuraVent's Engineering Department services the needs of customers with unique requirements. ommercial pplications ommercial projects may require custom parts and unique system designs. DuraVent offers complete project assistance for: Up to 6 Vent Diameters: Many commercial applications require large diameter systems due to a units size and output. Large diameters are available in single and double wall, featuring FasNSeal s triple lipped directional gaskets and built-in locking band, for safe and convenient installations. We provide expert sizing for your systems using proprietary tools compliant with SHRE standards and the EN4483 standard. Using a quick sketch layout tool we provide a layout drawing and product detail to support your quote. Where you need further detail, we provide full detailed 3D layouts to support your installation. DuraVent has the experience, talent and equipment to fabricate parts for most commercial venting systems. Engineering Services: Personalized system design services which offer comprehensive D submittal drawings and a complete bill of materials. ustom Parts: If your project requires innovative solutions contact Dura-Vent for custom parts to meet a specific project s needs. 'LEED' and USG logo is a trademark owned by the U.S. Green uilding ouncil and is used by permission. REYLE FasNSeal is registered trademark of M&G DuraVent M&G DuraVent, Inc. L83 9/0

FasNSeal 80/90 FasNSeal & FasNSeal W2 FasNSeal Flex

FasNSeal 80/90 FasNSeal & FasNSeal W2 FasNSeal Flex FasNSeal 80/90 FasNSeal & FasNSeal W FasNSeal Flex FSNSEL 80/90 hange to High Efficiency? Utilize Your Existing ommon Vent! FasNSeal 80/90 ap LISTINGS Storm ollar Flashing DuraVent s FNS 80/90 ombination

More information

FasNSeal 80/90 FasNSeal & FasNSeal W2 FasNSeal Flex

FasNSeal 80/90 FasNSeal & FasNSeal W2 FasNSeal Flex FasNSeal 80/90 FasNSeal & FasNSeal W FasNSeal Flex FSNSEL 80/90 hange to High Efficiency? Utilize Your Existing ommon Vent! FasNSeal 80/90 ap LISTINGS Storm ollar Flashing DuraVent s FNS 80/90 ombination

More information

AL29-4C (UNS S44735) Direct Vent System for Category II, III & IV Heating Equipment 3 through 16

AL29-4C (UNS S44735) Direct Vent System for Category II, III & IV Heating Equipment 3 through 16 L29- (UNS S7) Direct Vent System for ategory II, III & IV Heating Equipment through Set the standard as the first vent system with a built-in gasket and locking band, designed for high efficiency gas heaters

More information

CVS. Venting System for Category II, III, and IV gas appliances. Listed to UL-1738 and ULC S636.

CVS. Venting System for Category II, III, and IV gas appliances. Listed to UL-1738 and ULC S636. VS Venting System for ategory II, III, and IV gas appliances. Listed to UL-1738 and UL S636. PelletVent venting system. Listed to UL 641, UL S609, and UL/ORD 441. Unitized venting system for DirectVent

More information

Technical and Dimensional Data. Saf-T Vent SC Plus

Technical and Dimensional Data. Saf-T Vent SC Plus Technical and Dimensional Data Saf-T Vent S Plus 3"/5" & 4"/7" oncentric Reduced learance Double Wall for Special Gas Vent and/or Sealed ombustion Systems lso For Venting Listed Gas or Oil Fired ppliances

More information

PelletVent Pro. Biofuel venting system. UL 641, ULC S609, and ULC/ORD C441.

PelletVent Pro. Biofuel venting system. UL 641, ULC S609, and ULC/ORD C441. PelletVent Pro iofuel venting system. UL 641, ULC S609, and ULC/ORD C441. Specifications pplications PelletVent Pro is a venting system designed for stoves and inserts that use wood pellets and oil fuel.

More information

ULC S636 System. PolyPro. PolyPro Flex. Terminations

ULC S636 System. PolyPro. PolyPro Flex. Terminations PolyPro Polypropylene venting products for high-efficiency condensing appliance installations. Chloride free, environmentally safe. Listed to ULC-S636. Specifications pplications PolyPro is a polypropylene

More information

Corr/Guard PRESSURE RATED VENTING SYSTEM IMPORTANT: DO NOT INSTALL WITHOUT FIRST READING THESE INSTRUCTIONS VERY CAREFULLY.

Corr/Guard PRESSURE RATED VENTING SYSTEM IMPORTANT: DO NOT INSTALL WITHOUT FIRST READING THESE INSTRUCTIONS VERY CAREFULLY. CORR/GUARD INSTALLATION INSTRUCTIONS This symbol on the nameplate means this product is listed by Underwriters Laboratories Inc. Tested to UL1738 / CAN / ULCS636-1995 Listing No. MH26687 Testing No. 11EN

More information

DuraPlus HTC. All-fuel, double-wall chimney system. ULC S629.

DuraPlus HTC. All-fuel, double-wall chimney system. ULC S629. DuraPlus HTC ll-fuel, double-wall chimney system. ULC S629. Specifications pplications DuraPlus HTC is a double-wall, all-fuel chimney system for both the U.S. and Canada for use with wood stoves; fireplaces;

More information

DURAVENT POLYPRO VENTING PRODUCTS

DURAVENT POLYPRO VENTING PRODUCTS DURVENT POLYPRO VENTING PRODUCTS INDEX FLEX VENTING SYSTEM DPTER KIT... 14-11 -VENT RETROFIT DPTERS... 14-10 CHIMNEY CP... 14-10 CHIMNEY LINING KIT... 14-10 CHIMNEY SUPPORT... 14-11 COUPLER DPTER... 14-12

More information

FLANGED CORR/GUARD CORR/GUARD INSTALLATION INSTRUCTIONS

FLANGED CORR/GUARD CORR/GUARD INSTALLATION INSTRUCTIONS CORR/GUARD INSTALLATION INSTRUCTIONS This symbol on the nameplate means this product is listed by Underwriters Laboratories Inc. Tested to UL1738 / CAN / ULCS636-08 Listing No. MH26687 Testing No. 11EN

More information

ANY EVERY ONE ONE No matter what the venting application, from gas fired to oil to all fuel heating equipment, Z-FLEX is your one-stop solution.

ANY EVERY ONE ONE No matter what the venting application, from gas fired to oil to all fuel heating equipment, Z-FLEX is your one-stop solution. NY EVERY ONE ONE No matter what the venting application, from gas fired to oil to all fuel heating equipment, Z-FLEX is your one-stop solution. Specialists in Flexible Z-FLEX has been providing flexible

More information

DirectVent Pro CVS. Unitized, co-axial venting system for direct vent gas or propane stoves, and fireplaces.

DirectVent Pro CVS. Unitized, co-axial venting system for direct vent gas or propane stoves, and fireplaces. DirectVent Pro Unitized, co-axial venting system for direct vent gas or propane stoves, and fireplaces. VS Venting System for ategory II, III, and IV gas appliances. Listed to UL-1738 and UL S636. Specifications

More information

SMALL DIAMETER CORR/GUARD & SLEEVED CORR/GUARD

SMALL DIAMETER CORR/GUARD & SLEEVED CORR/GUARD CORR/GUARD INSTALLATION INSTRUCTIONS This symbol on the nameplate means this product is listed by Underwriters Laboratories Inc. Tested to UL1738 / CAN / ULCS636-08 Listing No. MH26687 Testing No. 11EN

More information

PelletVent Multi-fuel venting system. UL 641.

PelletVent Multi-fuel venting system. UL 641. PelletVent Multi-fuel venting system. UL 641. Specifications Applications PelletVent is designed for venting of pellet stoves and inserts. Consult appliance manual for additonal requirements. Materials

More information

For Category I, II, III & IV Heating Appliances. 3" through 16" Diameters. Edition 1

For Category I, II, III & IV Heating Appliances. 3 through 16 Diameters. Edition 1 For ategory I, II, III & IV Heating ppliances 3" through 16" s Edition 1 SW Special Gas Vent Table of ontents INTRODUTION...........................2-3 STRIGHT LENGTHS 6" Length................................4

More information

Pellet Stove. Flex Pipe. Appliance Connector

Pellet Stove. Flex Pipe. Appliance Connector Installation Instructions & Owners Maintenance Guide DT-M Direct-Temp for Multi Fuel L-Vent / Vent System for Pellet, Corn and other Bio-Fuel Burning Appliances Introduction Direct-Temp for Multi-Fuel

More information

PelletVent Pro. Biofuel venting system. UL 641, ULC S609, and ULC/ORD C441.

PelletVent Pro. Biofuel venting system. UL 641, ULC S609, and ULC/ORD C441. PelletVent Pro iofuel venting system. UL 641, ULC S609, and ULC/ORD C441. Specifications Applications PelletVent Pro is a venting system designed for stoves and inserts that use wood pellets and oil fuel.

More information

PelletVent Pro. Biofuel venting system. UL 641, ULC S609, and ULC/ORD C441.

PelletVent Pro. Biofuel venting system. UL 641, ULC S609, and ULC/ORD C441. PelletVent Pro iofuel venting system. UL 641, ULC S609, and ULC/ORD C441. Specifications Applications PelletVent Pro is a venting system designed for stoves and inserts that use wood pellets and oil fuel.

More information

SUBMITTAL RECORD. ULC S636 - PolyPro. Single-Wall Double-Wall Concentric Flex

SUBMITTAL RECORD. ULC S636 - PolyPro. Single-Wall Double-Wall Concentric Flex SUMITTL RECORD ULC S636 - PolyPro Polypropylene vent pipe for use with NSI Category II and IV gas-burning appliances, including high efficiency water heaters, condensing boilers and warm air furnaces.

More information

Installation and Maintenance Instructions

Installation and Maintenance Instructions Commercial & Industrial Positive Pressure or Condensing AL 29-4C Stainless Steel High Challenge Special Gas Vent Also for Natural Draft Appliances 3",4",5",6",7",8",9",10" and 12" Diameter Special Gas

More information

Easy to assemble. Silicone gasket sealed. Laser-welded seams. Smooth joint connections. 360 Lock-Tab secure rotation

Easy to assemble. Silicone gasket sealed. Laser-welded seams. Smooth joint connections. 360 Lock-Tab secure rotation Easy to assemble Silicone gasket sealed Laser-welded seams Smooth joint connections 360 Lock-Tab secure rotation Evenly spaced inner and outer pipes Continuous column of air insulation Ultimate Pellet

More information

PelletVent Pro horizontal Kit. PelletVent Pro. PelletVent Pro Vertical Kit - Cathedral. PelletVent Pro Pellet Chimney

PelletVent Pro horizontal Kit. PelletVent Pro. PelletVent Pro Vertical Kit - Cathedral. PelletVent Pro Pellet Chimney PelletVent Pro horizontal Kit Kit includes: Round horizontal Cap, Wall Thimble, and Appliance Adapter. Pipe lengths not included. 4 Kit includes a 3-4 Appliance Adapter/Increaser, painted black. 3 3PVP-KHA

More information

Combustion Air System DVL. DuraBlack. Triple-wall stovepipe system designed to provide air for combustion through its components. ULC S641.

Combustion Air System DVL. DuraBlack. Triple-wall stovepipe system designed to provide air for combustion through its components. ULC S641. Combustion ir System Triple-wall stovepipe system designed to provide air for combustion through its components. ULC S641. DVL Double-wall interior close clearance stovepipe for connecting woodstoves to

More information

NovaVent. Dimensional Data

NovaVent. Dimensional Data NovaVent Dimensional Data NovaVent The new vent system designed and engineered for today s competitive sales environment. NovaVent NovaVent is designed and engineered to meet the requirements of gas-fired

More information

FasNSeal. Installation Instructions

FasNSeal. Installation Instructions Installation Instructions FasNSeal & FasNSeal W2 Single-wall and Double-wall special gas vent FasNSeal Flex Flexible chimney liner for special gas vent for Category II, III, and IV appliances FasNSeal

More information

The intelligent alternative for flue gas venting systems

The intelligent alternative for flue gas venting systems The intelligent alternative for flue gas venting systems FIRST LISTED InnoFlue is the first polymeric vent system tested and listed to ULC-S636 and UL-1738 in North America Intelligent for a good reason

More information

Saf-T Vent SC Plus/SC 316

Saf-T Vent SC Plus/SC 316 Installation and Maintenance Instructions Saf-T Vent SC Plus/SC 316 Double Wall One Inch Air Space Special Gas Vent For Venting Residential and Light Commercial Appliances Category I,II,III,IV Appliances

More information

TYPE L VENT / VENT SYSTEM FOR PELLET BURNING APPLIANCES

TYPE L VENT / VENT SYSTEM FOR PELLET BURNING APPLIANCES INSTALLATION INSTRUCTIONS & MAINTENANCE GUIDE TYPE L VENT / VENT SYSTEM FOR PELLET BURNING APPLIANCES LISTED TO ULC-S609 & UL641 A MAJOR CAUSE OF VENT RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES

More information

Z-VENT MODEL SVE SERIES III INSTALLATION AND MAINTENANCE INSTRUCTIONS

Z-VENT MODEL SVE SERIES III INSTALLATION AND MAINTENANCE INSTRUCTIONS Z-VENT MODEL SVE SERIES III INSTALLATION AND MAINTENANCE INSTRUCTIONS 3 & 4 SPECIAL STAINLESS STEEL VENTING SYSTEM FOR GAS BURNING APPLIANCES CATEGORY I, II, III, & IV TESTED AND LISTED BY UNDERWRITERS

More information

GOLD GV. Venting Supplement for 3 venting. Water Boiler Series 3 & 4

GOLD GV. Venting Supplement for 3 venting. Water Boiler Series 3 & 4 GOLD GV Water Boiler Series 3 & 4 Venting Supplement for 3 venting Special gas vent system vent and combustion air supplement for 3 diameter venting. The following manufacturers AL29-4C Stainless Steel

More information

All-fuel, double-wall chimney system. UL 103 HT, UL 103, and ULC S604.

All-fuel, double-wall chimney system. UL 103 HT, UL 103, and ULC S604. DuraTech ll-fuel, double-wall chimney system. UL 103 HT, UL 103, and UL S60. DuraTech ll-fuel himney Typical Installations For 5-2 DuraTech *updated typicals* 6 1 19 8 16 1 19 5 1 8 1 6 2 Installation

More information

C. Manufactured double wall chimneys for fuel fired equipment. D. NFPA 54 - National Fuel Gas Code; National Fire Protection Association; 2009.

C. Manufactured double wall chimneys for fuel fired equipment. D. NFPA 54 - National Fuel Gas Code; National Fire Protection Association; 2009. SECTION 235100 - BREECHINGS, CHIMNEYS, AND STACKS PART 1 GENERAL 1.1 SECTION INCLUDES A. Fabricated breechings. B. Manufactured chimneys for gas fired equipment. C. Manufactured double wall chimneys for

More information

Installation and Maintenance Instructions. Double Wall AL 29-4C Stainless Steel Special Gas Vent and Type L Vent

Installation and Maintenance Instructions. Double Wall AL 29-4C Stainless Steel Special Gas Vent and Type L Vent Installation and Maintenance Instructions Saf-T Vent CI Plus Double Wall AL 29-4C Stainless Steel Special Gas Vent and Type L Vent For Venting Commercial & Industrial Appliances Condensing Appliances Category

More information

GWS. Venting Manual. Gas-Fired Water Boilers. Hazard definitions. Contents. Venting method definitions

GWS. Venting Manual. Gas-Fired Water Boilers. Hazard definitions. Contents. Venting method definitions GWS Gas-Fired Water Boilers Venting Manual Hazard definitions Contents Page Hazards that will cause severe personal injury, death or substantial property damage. Hazards that can cause severe personal

More information

VENT SYSTEM COMPONENTS

VENT SYSTEM COMPONENTS Chimney Liner Kits Chimney Liners - All Fuel Chimney Liners - Gas Made from durable, corrosion-resistant type 316 stainless steel Designed to be used with wood, oil, coal and non-condensing gas-fired appliances

More information

By Bernard Dalsin Mfg. Co. Installation and Operating Instructions Read these instructions and keep them for future reference

By Bernard Dalsin Mfg. Co. Installation and Operating Instructions Read these instructions and keep them for future reference By Bernard Dalsin Mfg. Co. 5205 208 th St Farmington MN 55024 L-VENT TYPE 3 "and 4" Factory-built venting system for wood pellet, corn or biomass and low-temperature gas or liquid fuel appliances Installation

More information

Installation and Maintenance Instructions

Installation and Maintenance Instructions Installation and Maintenance Instructions Saf-T Vent Model EZ Seal and Model GC Single Wall AL 29-4C Stainless Steel Gas Vent Connector Chimney Liner & Special Gas Vent (USA) / Type BH Vent Class I/II

More information

GOLD. Venting Supplement. Water Boiler Series 3 & 4. for 3" venting

GOLD. Venting Supplement. Water Boiler Series 3 & 4. for 3 venting GOLD GV Water Boiler Series 3 & 4 Venting Supplement for 3" venting Special gas vent system vent and combustion air supplement for 3" diameter venting. The following manufacturers AL29-4C Stainless Steel

More information

Installation and Maintenance Instructions

Installation and Maintenance Instructions Installation and Maintenance Instructions Saf-T Vent Model EZ Seal Single Wall AL 29-4C Stainless Steel Gas Vent Connector Chimney Liner & Special Gas Vent (USA) / Type BH Vent Class I/II (Canada) For

More information

BDM Direct Vent systems are for use with direct vent gas fired appliances.

BDM Direct Vent systems are for use with direct vent gas fired appliances. INSTALLATION INSTRUCTIONS Pro-Form DIRECT VENT SYSTEM Tested to ANSI Z21.88-2009 /CSA 2.33-2009 REPORT # 369-P-02b-6.5 Read through all venting and appliance instructions before beginning your installation.

More information

Combustion Air System DVL. DuraBlack. Triple-wall stovepipe system designed to provide air for combustion through its components. ULC S641.

Combustion Air System DVL. DuraBlack. Triple-wall stovepipe system designed to provide air for combustion through its components. ULC S641. System Triple-wall stovepipe system designed to provide air for combustion through its components. ULC S641. DVL Double-wall interior close clearance stovepipe for connecting woodstoves to chimney. ULC

More information

GAS FIRED BOILERS FOR FORCED HOT WATER VENTING ADDENDUM. ECR International Ltd. - Olsen Division P.O. Box 900 Wallaceburg, Ont.

GAS FIRED BOILERS FOR FORCED HOT WATER VENTING ADDENDUM. ECR International Ltd. - Olsen Division P.O. Box 900 Wallaceburg, Ont. ODV-B GAS FIRED BOILERS FOR FORCED HOT WATER VENTING ADDENDUM ECR International Ltd. - Olsen Division P.O. Box 900 Wallaceburg, Ont. N8A5E5 TABLE OF CONTENTS HORIZONTAL PIPING... PAGES 1-10 WARNINGS...

More information

VP Pellet Pipe. For pellet burning stoves. FEATURES

VP Pellet Pipe. For pellet burning stoves. FEATURES CATALOG VP Pellet Pipe For pellet burning stoves. Selkirk gives you the safe, efficient, and cost-effective venting system that's engineered precisely for pellet burning stoves. FEATURES Available in 3"

More information

Venting Supplement. Direct Vent Through-Roof or Through-Unused-Chimney. Water Boiler Series 3 & 4

Venting Supplement. Direct Vent Through-Roof or Through-Unused-Chimney. Water Boiler Series 3 & 4 GOLD GV Water Boiler Series 3 & 4 Venting Supplement Direct Vent Through-Roof or Through-Unused-Chimney For use with Weil-McLain Through-Roof or Through- Unused-Chimney Termination Kit Kit part # 382-200-435

More information

For current product listing visit:

For current product listing visit: Corr/Guard Special Gas Vent Appliance Adapters 04/01/11 For current product listing visit: www.mtlfab.com/media/l2159.pdf Metal-Fab, Inc. Corr/Guard Appliance Adapters Table of Contents Cross Reference

More information

Installation and Maintenance Instructions

Installation and Maintenance Instructions Installation and Maintenance Instructions Saf-T Vent Model EZ Seal and Model GC Single Wall AL 29-4C Stainless Steel Gas Vent Connector Chimney Liner & Special Gas Vent (USA) / Type BH Vent Class I/II

More information

That s The Metal-Fab Way Experience The Difference

That s The Metal-Fab Way Experience The Difference 1 Faster. Safer. etter. Metal-Fab provides complete and comprehensive venting solutions to the HV, hearth and plumbing markets. Founded in 1959, on the premise that better products and services would be

More information

Direct Exhaust Venting Kit Instructions

Direct Exhaust Venting Kit Instructions CONDENSING GAS BOILER 220/299/300/399 Direct Exhaust Venting Kit Instructions Evergreen 220/299/300/399 Kit part number 383-500-769 STOP! Read before proceeding Hazard definitions The following defined

More information

Gas Stoves. H15-10 Direct Vent Gas Stove. Model H15-NG10 H15-LP10. Approved Venting Systems

Gas Stoves. H15-10 Direct Vent Gas Stove. Model H15-NG10 H15-LP10. Approved Venting Systems H15-10 Direct Vent Gas Stove Model H15-NG10 H15-LP10 Fuel Type Natural Gas Propane Minimum Supply Pressure 5.0 W.C. (1.25 kpa) 12.0 W.C. (3.00 kpa) Manifold Pressure - High 3.8 W.C. (0.95 kpa) 11 W.C.

More information

Installation & Maintenance Instructions

Installation & Maintenance Instructions Installation & Maintenance Instructions Listed & Tested to UL641, ULC-S609, ULC/ORD C441 AMERIVENT Model PVP Pellet Pipe Plus Vent Connector for Pellet-Fuel Appliances and Other Low-Temperature Applications

More information

GOLD GV. Venting Supplement. Water boiler Series 3. Special gas vent system vent and combustion air supplement. Hazard definitions.

GOLD GV. Venting Supplement. Water boiler Series 3. Special gas vent system vent and combustion air supplement. Hazard definitions. GOLD GV Water boiler Series 3 Venting Supplement Special gas vent system vent and combustion air supplement ProTech Systems AL29-4C Stainless Steel Special Gas Vent System may be used in new installations

More information

Saf-T Vent Model EZ Seal Plus/EZ 316 Single Wall Gas Vent Connector Chimney Liner & Special Gas Vent (USA) / Type BH Vent Class I/II (Canada)

Saf-T Vent Model EZ Seal Plus/EZ 316 Single Wall Gas Vent Connector Chimney Liner & Special Gas Vent (USA) / Type BH Vent Class I/II (Canada) Installation and Maintenance Instructions Saf-T Vent Model EZ Seal Plus/EZ 316 Single Wall Gas Vent Connector Chimney Liner & Special Gas Vent (USA) / Type BH Vent Class I/II (Canada) For Venting Residential,

More information

Twin wall Air Gap Insulated Zalutite & Aluminium Commercial Gas Vent Chimney System

Twin wall Air Gap Insulated Zalutite & Aluminium Commercial Gas Vent Chimney System Q Twin wall ir Gap Insulated Zalutite & luminium ommercial Gas Vent himney System Designed for Individual and Modular Natural Draught Gravity Flow himney pplications PRODUT INFORMTION INTRODUTION Q is

More information

Direct Vent System. for PELLET STOVES FEATURES. Includes all Selkirk Model VP Pellet Pipe and Direct-Temp components needed to complete a system

Direct Vent System. for PELLET STOVES FEATURES. Includes all Selkirk Model VP Pellet Pipe and Direct-Temp components needed to complete a system CTLOG Direct Vent System for PELLET STOVES Includes all Selkirk Model VP Pellet Pipe and Direct-Temp components needed to complete a system Direct-Temp for pellet stoves is the revolutionary, high-performance

More information

2012 INTERNATIONAL FUEL GAS CODE VENTS

2012 INTERNATIONAL FUEL GAS CODE VENTS 2012 INTERNATIONAL FUEL GAS CODE SECTION 502 (IFGC) VENTS 502.1 General. All vents, except as provided in Section 503.7, shall be listed and labeled. Type B and BW vents shall be tested in accordance with

More information

PolyPro: For Venting Condensing Appliances Environmentally Safe Alternative Lower Over-All Cost Than PVC Engineered Terminations Fast, Easy To Install

PolyPro: For Venting Condensing Appliances Environmentally Safe Alternative Lower Over-All Cost Than PVC Engineered Terminations Fast, Easy To Install PolyPro : For Venting Condensing Appliances Environmentally Safe Alternative Lower Over-All Cost Than PVC Engineered Terminations Fast, Easy To Install Being Green, Being Responsible. DuraVent looks for

More information

DT-M Direct-Temp for Multi Fuel L-Vent / Vent System for Pellet, Corn and other Bio-Fuel Burning Appliances

DT-M Direct-Temp for Multi Fuel L-Vent / Vent System for Pellet, Corn and other Bio-Fuel Burning Appliances Installation Instructions & Owners Maintenance Guide DT-M Direct-Temp for Multi Fuel L-Vent / Vent System for Pellet, Corn and other Bio-Fuel Burning Appliances Introduction Direct-Temp for Multi-Fuel

More information

Mitchell Metal Products, Inc.

Mitchell Metal Products, Inc. Mitchell Metal Products, Inc. Mitchell Metal Products Kosciusko, Mississippi Established 1924 H i g h w a y 1 2 E P. O. B o x 7 8 9 K o s c i u s k o, M S 3 9 0 9 0 O f f i c e : 6 6 2-2 8 9-7 11 0 o r

More information

Installation Instructions

Installation Instructions Installation Instructions Type B Gas Vent Model E/R 3" 8" ECCO TYPE B GAS VENT AND ACCESSORIES ARE FOR USE ONLY WITH LISTED CATEGORY 1 GAS-FIRED APPLIANCES OR APPLIANCES LISTED FOR USE WITH TYPE B GAS

More information

Installation and Maintenance Instructions

Installation and Maintenance Instructions Installation and Maintenance Instructions Saf-T Vent Model EZ Seal Single Wall AL 29-4C Stainless Steel Gas Vent Connector Chimney Liner & Special Gas Vent (USA) / Type BH Vent Class I/II (Canada) For

More information

5"x 8" DIRECT VENT INSTALLATION INSTRUCTIONS FOR DECORATIVE GAS APPLIANCES AND DIRECT VENT HEATERS APPLICATION

5x 8 DIRECT VENT INSTALLATION INSTRUCTIONS FOR DECORATIVE GAS APPLIANCES AND DIRECT VENT HEATERS APPLICATION 5"x 8" DIRECT VENT INSTALLATION INSTRUCTIONS FOR DECORATIVE GAS APPLIANCES AND DIRECT VENT HEATERS APPLICATION These instructions apply to the Simpson Dura-Vent 5"x 8" Direct Vent System. This venting

More information

Submittal Data Model AM Low Intensity Adaptive Modulating Infrared Heaters

Submittal Data Model AM Low Intensity Adaptive Modulating Infrared Heaters Submittal ata Model M ow Intensity daptive Modulating Infrared Heaters Project Engineer ontractor Model # ate: Submitted by: pproved by: General Specification Fuel Type (heck one) Natural Gas PG Heat Exchanger

More information

Venting Supplement Saf-T Vent 3" venting Special gas vent system vent and combustion air supplement for 3" diameter venting Hazard definitions

Venting Supplement Saf-T Vent 3 venting Special gas vent system vent and combustion air supplement for 3 diameter venting Hazard definitions GOLD GV Water Boiler Series 3 & 4 Venting Supplement 3" venting Special gas vent system vent and combustion air supplement for 3" diameter venting Heat-Fab, Inc. AL29-4C Stainless Steel Special Gas Vent

More information

200i. Vent/air manual. Installation instructions for vent and air piping. Also read and follow: 200i Boiler manual 200i Control manual

200i. Vent/air manual. Installation instructions for vent and air piping. Also read and follow: 200i Boiler manual 200i Control manual M2i-VAM-2 Cast iron condensing boiler 200i Vent/air manual Installation instructions for vent and air piping Also read and follow: 200i Boiler manual 200i Control manual This manual is intended only for

More information

Manual Addendum. This Addendum needs to be used in conjunction with the Evergreen Boiler Manual P/N _0518

Manual Addendum. This Addendum needs to be used in conjunction with the Evergreen Boiler Manual P/N _0518 Manual Addendum This Addendum needs to be used in conjunction with the Evergreen Boiler Manual P/N 550-100-191_0518 ATTENTION to installers and homeowners of Evergreen boilers. KEEP THIS ADDENDUM WITH

More information

flexible venting simply perfect cost efficient convenient durable Est FREEDOM VENTING FLEX

flexible venting simply perfect cost efficient convenient durable Est FREEDOM VENTING FLEX flexible venting simply perfect cost efficient convenient durable Est. 1990 FLEX FREEDOM VENTING Introduction Freedom Flex Venting systems are top of the line when it comes to materials, cost efficiency

More information

ICC Model VIC SINGLE WALL SPECIAL GAS VENT INSTALLATION AND MAINTENANCE INSTRUCTIONS

ICC Model VIC SINGLE WALL SPECIAL GAS VENT INSTALLATION AND MAINTENANCE INSTRUCTIONS ICC Model VIC SINGLE WALL SPECIAL GAS VENT INSTALLATION AND MAINTENANCE INSTRUCTIONS The ICC Model VIC is a listed venting system designed for venting commercial and industrial appliances, condensing appliances,

More information

INSTALLATION OF VENTING SYSTEM COMPONENTS WARNING

INSTALLATION OF VENTING SYSTEM COMPONENTS WARNING INSTALLATION OF VENTING SYSTEM COMPONENTS WARNING When installing the EVERHOT IGI model series direct vent water heaters, use only EVERHOT vent/air intake system kits and components. Installation and service

More information

Model IVSI Positive Pressure Venting Systems

Model IVSI Positive Pressure Venting Systems C O M M E R C I A L A N D I N D U S T R I A L V E N T I N G Model IVSI Positive Pressure Venting Systems Ideal for discharging exhaust gases and fumes from boilers, heaters, ovens, engines, turbines and

More information

Bring In the Fresh Air

Bring In the Fresh Air ring In the Fresh Air ombustion Air System For DuraTech, DuraPlus HT and PelletVent Pro DuraVent s new, exclusive, patentpending DuraPro ombustion Air System Wall Thimble and eiling Support oxes is the

More information

SEPARATED COMBUSTION. General WARNING

SEPARATED COMBUSTION. General WARNING Form I-UD-V-SC (09-17) Obsoletes Form I-UD-V-SC (Version 05-17) APPLIES TO: Venting Requirements for Model UDAS and Model UDBS and Instructions for Combustion Air Inlet / Vent Terminal Options CC6 and

More information

Installation guide and material checklists

Installation guide and material checklists Featuring Flexibility Installation guide and material checklists Series 3 This guide must only be used by a quali!ed heating installer/service technician. Read all instructions, including the boiler manual

More information

SUBJECT: SELKIRK MODEL DT DIRECT VENT SYSTEM FOR PELLET & CORN FIRED APPLIANCES / TERMINATION CLEARANCES TO OPENINGS IN BUILDINGS

SUBJECT: SELKIRK MODEL DT DIRECT VENT SYSTEM FOR PELLET & CORN FIRED APPLIANCES / TERMINATION CLEARANCES TO OPENINGS IN BUILDINGS Selkirk LLC Selkirk LLC Research & Development State Route 93 North & Sutton Road P.O. Box 631 Logan, OH 43138 9/21/2006 TO: Our Valued Customers FROM: Glen Edgar Director R&D SUBJECT: SELKIRK MODEL DT

More information

H35 Direct Vent Gas Stove. 17,500 BTU/h (5.13 kw) 34,000 BTU/h (9.97 kw) 15,000 BTU/h (4.39 kw) 28,500 BTU/h (8.35 kw)

H35 Direct Vent Gas Stove. 17,500 BTU/h (5.13 kw) 34,000 BTU/h (9.97 kw) 15,000 BTU/h (4.39 kw) 28,500 BTU/h (8.35 kw) H35 Direct Vent Gas Stove Model H35-NG10 H35-LP10 Fuel Type Natural Gas Propane Minimum Supply Pressure 5.0 W.C. (1.25 kpa) 12.0 W.C. (3.00 kpa) Manifold Pressure - High 3.8 W.C. (0.94 kpa) 11 W.C. (2.74

More information

H35 Direct Vent Gas Stove. 17,500 BTU/h (5.13 kw) 34,000 BTU/h (9.97 kw) 15,000 BTU/h (4.39 kw) 28,500 BTU/h (8.35 kw)

H35 Direct Vent Gas Stove. 17,500 BTU/h (5.13 kw) 34,000 BTU/h (9.97 kw) 15,000 BTU/h (4.39 kw) 28,500 BTU/h (8.35 kw) H35 Direct Vent Gas Stove Model H35-NG10 H35-LP10 Fuel Type Natural Gas Propane Minimum Supply Pressure 5.0 W.C. (1.25 kpa) 12.0 W.C. (3.00 kpa) Manifold Pressure - High 3.8 W.C. (0.94 kpa) 11 W.C. (2.74

More information

INSTALLATION AND OPERATING INSTRUCTIONS TABLE OF CONTENTS IMPORTANT

INSTALLATION AND OPERATING INSTRUCTIONS TABLE OF CONTENTS IMPORTANT C US This manual must be left with owner and should be hung on or adjacent to the boilerfor reference. COMMON VENTING MODELS CHS-300 through CHS-399 INSTALLATION AND OPERATING INSTRUCTIONS TABLE OF CONTENTS

More information

POWER VENT. Standard Power Vent, Fan Type Unit Heaters: Standard Power Vent, Blower Type Unit Heaters: General WARNING WARNING. Model UDAP & Model APD

POWER VENT. Standard Power Vent, Fan Type Unit Heaters: Standard Power Vent, Blower Type Unit Heaters: General WARNING WARNING. Model UDAP & Model APD General APPLIES TO: Standard Power Vent, Fan Type Unit Heaters: Model UDAP & Model APD Standard Power Vent, Blower Type Unit Heaters: Model UDBP Form I-UD&APD Series-V-PV (05-17) Obsoletes I-UD&APD Series-V-PV

More information

Gas-Fired Fan Assisted Hot Water Boilers INSTALLATION INSTRUCTIONS These instructions must be affixed on or adjacent to the boiler

Gas-Fired Fan Assisted Hot Water Boilers INSTALLATION INSTRUCTIONS These instructions must be affixed on or adjacent to the boiler D E S I G N E D T O L E A D BWF Series Gas-Fired Fan Assisted Hot Water Boilers INSTALLATION INSTRUCTIONS These instructions must be affixed on or adjacent to the boiler Models: BWF061 BWF095 BWF128 BWF162

More information

Installation Instructions. PolyPro Single-Wall Gas Vent System for Category II & IV Gas-Burning Appliances. PolyPro

Installation Instructions. PolyPro Single-Wall Gas Vent System for Category II & IV Gas-Burning Appliances. PolyPro Installation Instructions PolyPro Single-Wall Gas Vent System for Category II & IV Gas-Burning Appliances PolyPro A MAJOR CAUSE OF VENT RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES)

More information

SL-VENT (oil and gas vent) For use with oil or gas fired appliances. Listed to ULC-609 and UL-641. Available in 5, 6, 7 and 8 I. D.

SL-VENT (oil and gas vent) For use with oil or gas fired appliances. Listed to ULC-609 and UL-641. Available in 5, 6, 7 and 8 I. D. Typical Installations 0 8 9 Vertical Installation. Vertical Termination ap. Storm ollar. Flashing. Roof Support. Length. ttic Radiation Shield. Firestop 8. ecorative lack Plate 9. Length (lack) 0. Insulation

More information

Gas-Fired Fan Assisted Hot Water Boilers INSTALLATION INSTRUCTIONS These instructions must be affixed on or adjacent to the boiler

Gas-Fired Fan Assisted Hot Water Boilers INSTALLATION INSTRUCTIONS These instructions must be affixed on or adjacent to the boiler D E S I G N E D T O L E A D BWF Series Gas-Fired Fan Assisted Hot Water Boilers INSTALLATION INSTRUCTIONS These instructions must be affixed on or adjacent to the boiler Models: BWF061 BWF095 BWF128 BWF162

More information

CHIMNEYS AND VENTS CHAPTER 8

CHIMNEYS AND VENTS CHAPTER 8 CHAPTER 8 CHIMNEYS AND VENTS SECTION 801 GENERAL 801.1 Scope. This chapter shall govern the installation, maintenance, repair and approval of factory-built chimneys, chimney liners, vents and connectors.

More information

Venting System For Pellet and Corn Stoves. PelletVent Pro. C o m p l e t e V e n t i n g S o l u t i o n s f o r t h e H e a r t h I n d u s t r y

Venting System For Pellet and Corn Stoves. PelletVent Pro. C o m p l e t e V e n t i n g S o l u t i o n s f o r t h e H e a r t h I n d u s t r y Venting System For Pellet and Corn Stoves PelletVent Pro C o m p l e t e V e n t i n g S o l u t i o n s f o r t h e H e a r t h I n d u s t r y ii PelletVent Pro For Stoves Burning Pellets & Corn Simpson

More information

Installation, Operation and Service Manual

Installation, Operation and Service Manual Installation, Operation and Service Manual Direct Vent CO-AXIAL DIRECT VENT SYSTEM DVS-100 INSTALLATIONS MUST MEET ALL LOCAL AND FEDERAL CODES THAT MAY DIFFER FROM THIS MANUAL Please read the manual in

More information

SEPARATED COMBUSTION WARNING

SEPARATED COMBUSTION WARNING CUSTOMER AGENCY PROCESS CQS CONVERGENT QUALITY SYSTEM PRODUCT WARRANTY START-UP Form I-SDH-V (Version.5) Obsoletes I-SDH-V (Version.4) Vent Installation Applies to: Venting Requirements for PREEVA Separated-Combustion

More information

INSTALLATION AND SERVICE MANUAL

INSTALLATION AND SERVICE MANUAL INSTALLATION AND SERVICE MANUAL VERTICAL COMBUSTION AIR INLET KITS CATEGORY III VENTING FOR SEPARATED COMBUSTION TUBULAR GAS FIRED UNIT HEATERS USE 5 INCH KIT FOR UNITS WITH CAPACITIES 100,000 TO 250,000

More information

P P Gas Fireplace. P See Thru

P P Gas Fireplace. P See Thru P121-10 - P131-10 Gas Fireplace Model P121/P131-NG10 P121/P131-LP10 Fuel Type Natural Gas Propane Minimum Supply Pressure 5 W.C. (1.25 kpa) 12 W.C. (3.00 kpa) Manifold Pressure - High 3.8 W.C. (0.95 kpa)

More information

INS A T LL T A ION, OPER T A ING AND SERVICE INSTRUCTIONS FOR FREEDOM CONDENSING HIGH EFFICIENCY DIRECT VENT GAS - FIRED HOT

INS A T LL T A ION, OPER T A ING AND SERVICE INSTRUCTIONS FOR FREEDOM CONDENSING HIGH EFFICIENCY DIRECT VENT GAS - FIRED HOT INSTALLATION, OPERATING AND SERVICE INSTRUCTIONS FOR FREEDOM CONDENSING HIGH EFFICIENCY DIRECT VENT GAS - FIRED HOT WATER BOILER Warning: Improper installation, adjustment, alteration, service or maintenance

More information

EUTECTIC EC-10DV Series

EUTECTIC EC-10DV Series EUTECTIC EC-10DV Series DIRECT VENT OIL-FIRED WATER BOILER/NO. 2 OIL VENTING INSTALLATION INSTRUCTIONS CONTENTS..........................................PAGE Basic Guidelines..........................................1

More information

Infiniti Tankless Water Heater Series Featuring SRT (Scale Reduction Technology) The Infiniti Tankless Exclusive Technologies and Features

Infiniti Tankless Water Heater Series Featuring SRT (Scale Reduction Technology) The Infiniti Tankless Exclusive Technologies and Features The Infiniti Tankless Exclusive Technologies and Features Standard Features SRT Scale Reduction Technology Significantly reduces the scale build-up known to result in poor performance, additional maintenance,

More information

Ventis Direct Vent. Installation Instructions

Ventis Direct Vent. Installation Instructions entis Direct ent Installation Instructions A MAJOR CAUSE OF CHIMNEY RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES), TO COMBUSTIBLE MATERIALS. IT IS OF THE UTMOST IMPRORTANCE THAT

More information

SEPARATED COMBUSTION. General

SEPARATED COMBUSTION. General Form I-UD-V-SC (Version D) Obsoletes Form I-UD-V-SC (Version C) APPLIES TO: Venting Requirements for Model UDAS and Model UDBS and Instructions for Inlet / Vent Terminal Options CC6 and CC2 General This

More information

Vent and air piped through a side wall (concentric termination)

Vent and air piped through a side wall (concentric termination) Vent and air piped through a side wall (concentric termination) Read before proceeding The vent piping operates with positive pressure. The vent piping must be completely sealed and securely supported.

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS ELIMINATOR 36 Wood Burning Fireplace Models: 36E Non-Circulating (Smooth Face) I36E Non-Circulating (Smooth Face) Fully Insulated INSTALLATION INSTRUCTIONS SAVE THIS BOOK This book is valuable. In addition

More information

INSTALLATION AND SERVICE MANUAL

INSTALLATION AND SERVICE MANUAL INSTALLATION AND SERVICE MANUAL HORIZONTAL COMBUSTION AIR INLET KITS CATEGORY III VENTING FOR SEPARATED COMBUSTION TUBULAR GAS FIRED UNIT HEATERS USE 5 INCH KIT FOR UNITS WITH CAPACITIES 100,000 TO 250,000

More information

Gas Stoves. C34-10 Direct Vent Gas Stove. Side wall E F. Back wall F E. Model C34-NG10 C34-LP10

Gas Stoves. C34-10 Direct Vent Gas Stove. Side wall E F. Back wall F E. Model C34-NG10 C34-LP10 Back wall Gas Stoves Model C34-NG10 C34-LP10 Fuel Type Natural Gas Propane Minimum Supply Pressure 5.0 W.C. (1.25 kpa) 12.0 W.C. (3.00 kpa) Manifold Pressure - High 3.8 W.C. (0.95 kpa) 11 W.C. (2.74 kpa)

More information

CQS POWER VENT. General. Venting Requirements. Venting Instructions PREEVA Indoor, Power-Vented Heater Model PDH

CQS POWER VENT. General. Venting Requirements. Venting Instructions PREEVA Indoor, Power-Vented Heater Model PDH Applies to: Form I-PDH-V Venting Instructions PREEVA Indoor, Power-Vented Heater Model PDH CUSTOMER AGENCY PROCESS CQS CONVERGENT QUALITY SYSTEM PRODUCT WARRANTY START-UP Power-Vent Indoor Model PDH General

More information

Commercial Tankless Rack System

Commercial Tankless Rack System TNKLESS FREE STNDING K-TO-K LIGHTWEIGHT onstructed of anodized aluminum frame Utilizes the industry s lightest 199,000 TU high efficiency condensing tankless heater EXPNDLE Multiple design and installation

More information

Installation Instructions. PolyPro Single-Wall Gas Vent System for Category II & IV Gas-Burning Appliances. PolyPro

Installation Instructions. PolyPro Single-Wall Gas Vent System for Category II & IV Gas-Burning Appliances. PolyPro Installation Instructions PolyPro Single-Wall Gas Vent System for Category II & IV Gas-Burning Appliances PolyPro A MAJOR CAUSE OF VENT RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES)

More information