Mounting Kits. LWMB2 6" 6 3 /8" 5 7 /8" 2.6 lbs lbs. LCMB2 6" 5" 5 3 /4 2.3 lbs. 2.5 lbs.

Size: px
Start display at page:

Download "Mounting Kits. LWMB2 6" 6 3 /8" 5 7 /8" 2.6 lbs lbs. LCMB2 6" 5" 5 3 /4 2.3 lbs. 2.5 lbs."

Transcription

1 FEDERAL SIGNAL CORPORATION Mounting Kits Models LWMB2 and LCMB2 CUSTOM MOUNTING BRACKETS Heavy-duty construction Easy installation For walls and outside corners Indoor and outdoor use Replaces unsightly and hazardous makeshift supports 1 /2-inch, 3 /4-inch and 1-inch pipe mount Type 3R Federal Signal s Models LWMB2 and LCMB2 mounting brackets are specifically designed for use with Federal Signal s stationary warning lights to provide an easy and consistent means of mounting lights throughout a facility. Federal Signal s Models LWMB2 and LCMB2 are constructed of durable cast aluminum and sealed with gray powder coat paint. Easy to install, these units can be wired through the back of the bracket for electrical box mounting or through the threaded hole in the base for external 1 /2-inch conduit connection. Each kit includes a bracket, plate and mounting screws. Easy installation, heavy-duty construction and a professional appearance make the brackets suitable for use in commercial, institution and industrial environments. These brackets are suitable for any Type 3R application in ordinary (non Division 1/Division 2) environments. The LCMB2 and LWMB2 mounting kits may be used with the following Federal Signal models: 121S, 131ST, 131DST, 131C, 141(120V), 141ST, 225, 371, 371L, 371ST, 371DST, AV1, AV1ST, FB2PST and the FB24ST. Net Shipping Model Height Width Extension Weight Weight LWMB2 6" 6 3 /8" 5 7 /8" 2.6 lbs lbs. LCMB2 6" 5" 5 3 /4 2.3 lbs. 2.5 lbs.

2 MOUNTING KITS (LWMB2, LCMB2) Installation of a wall bracket on a 4" electrical box PLASTER RING OR ELECTRICAL BOX ADAPTER PLATE MOUNTING BRACKET ASSEMBLY Installation of a wall bracket with conduit wiring ANCHORS (NOT SUPPLIED) WALL MACH. SCREWS SET SCREWS WALL MOUNTING BRACKET MACH. SCREWS.028 HOLE SIZE SHEET METAL SCREWS BACKPLATE 1/2" TAPPED HOLE CONNECTOR 1/2" CONDUIT Installation of an outside corner bracket with conduit WALLS ANCHORS (NOT SUPPLIED) BACKPLATE.028 HOLE SIZE MACH. SCREWS SET SCREWS 1/2" TAPPED HOLE CORNER MOUNTING BRACKET CONNECTOR 1/2" CONDUIT HOW TO ORDER Specify model LCMB2 Corner Mount LWMB2 Wall Mount Please refer to Model Number Index LCMB2/LWMB2 beginning on page Federal Signal Dr., University Park, IL Tel: Fax:

3 FEDERAL SIGNAL CORPORATION Synchronous Strobe Module Model SSM SYNCHRONIZE LOW IN-RUSH FEDERAL SIGNAL STROBES Synchronizes strobe lights to 72 flashes per minute Mounts on double-gang electrical box UL1971 Approved for hearing impaired applications Polarized design allows for remote supervision Compatible with select Federal Signal model strobe lights (see chart) The Model SSM, Synchronous Strobe Module, is an electronic timing mechanism designed to energize select Federal Signal low in-rush 24VDC strobe lights simultaneously, while maintaining the ability to remotely supervise the strobe light circuit. This module is designed to synchronize a special series of Federal Signal strobe lights, which meet the requirement for Private-Mode Fire Alarm use, while maintaining the agency approval and environmental rating of the strobe light. The SSM is only compatible with Federal Signal brand strobe lights. See compatible models on the How to Order page. The SSM enables the customer to meet local building codes through a visually appealing single-flash created by the simultaneous control of strobe lights connected to it. Mixed signals are reduced to a minimum as reflection of many light pulses are now viewed as one single flash. The SSM mounts to the plaster ring of a double-gang electrical box, and requires 24 VDC at all times to operate the timing circuit. Screw terminals are provided for field termination of control wiring and a maximum of three non-explosion-proof strobe lights or two Explosion-proof strobe lights may be connected to each SSM. Electrically, the SSM should be mounted in the middle of the circuit, with a maximum cable distance of 100 from the SSM to each Strobe light. Supervision is accomplished the same as without the SSM, with a flash rate of 72 Flashes per minute in lieu of the advertised flash rate for each strobe light. The SSM is capable of switching 6 Amps of current. Please note: Not all strobe lights have the same in-rush current and therefore the SSM s circuit s switching potential may be reduced. Please see the application drawings on the second page. Operating Model Current Voltage SSM 0.95 amps 24VDC

4 VISUAL SYNCHRONOUS STROBE MODULE (SSM) FB24STHI 224XSTHI STROBE #1 FB24STHI 224XSTHI STROBE #2 FB24STHI 224XSTHI STROBE #3 STROBE SIGNAL 24VDC IN 24VDC OUT CONTROL PANEL POWER SUPPLY SYNC MODULE SSM RED BLACK RED BLACK RED BLACK IN OUT IN OUT IN OUT IN OUT IN OUT IN OUT END OF LINE RESISTOR 290A5130 FSEX HI STROBE #1 FSEX HI STROBE #2 CONTROL PANEL POWER SUPPLY STROBE SIGNAL 24VDC IN OUT IN IN IN OUT IN 24VDC OUT SYNC MODULE SSM RED BLACK RED BLACK OUT OUT END OF LINE RESISTOR SPECIFICATIONS Operating Temperature: 32 F to 120 F 0 C to 49 C Net Weight: 0.53 lbs kg Ship. Weight: 0.93 lbs kg Height: mm Width: mm Depth: mm HOW TO ORDER Specify model COMPATIBLE STROBE LIGHTS 224XST-024, Series C 225XST-I-024, Series B FB2PSTX-I-024, Series B FB2PST-I-024, Series B FB24ST-024, Series B FB24ST-HI-024, Series C 224XST-HI-024, Series B FSEX-HI-024, Series D FSEX-024, Series D 27XST-024, Series E REPLACEMENT PARTS Description PC Board Assembly 2 per circuit 2 per circuit 2 per circuit Part Number K A 2645 Federal Signal Dr., University Park, IL Tel: Fax:

5 FEDERAL SIGNAL CORPORATION Push Button Stations Model PS Series FOR VANDAL-RESISTANT ACTIVATION OF EMERGENCY SYSTEMS "Fire", "Evacuation", and "Emergency" stations available Quick reset Cover with alarm discourages tampering UL and cul Listed, CSFM Approved ADA Compliant Type 3R with cover and gasket These multi-purpose, initiating devices cover a wide range of industrial and commercial applications. The Federal Signal pushbutton stations function like a traditional fire alarm pull station, providing a simple contact closure to activate emergency equipment, audible and visual signals and alarm panels. The push button stations are available in two colors Red or Yellow. The red Emergency and yellow "Evacuation" units have a Push and Turn reset button. The red Fire unit has a Push and Key Lock reset button. Each unit is available with or without a tamper-resistant polycarbonate cover. Covered units work to protect against physical damage to the station and to prevent false alarms without restricting use in emergency situations. When the cover is lifted to gain access to the alarm, a piercing tone sounds, calling immediate attention to the area. The piezo horn is quiet once the cover is closed. Power to the piezo alarm is provided by a 9VDC battery (included). The sounder cover mounts easily over the station with four anchor screws. The terminal block provides easy installation and maintenance. Units mount on existing single-gang electrical boxes or 4" x 4" electrical boxes with plaster ring adapters (customer supplied). Units are UL and cul Listed, meeting Type 3R specifications for outdoor use with the cover and gasket. They are also ADA Compliant (requiring less than five foot pounds for activation). Contact ratings for the Push Button Stations are 3 amps and 1 amp. MODEL DESCRIPTION PUSH BUTTON STATION (Shown At Top) PSFI-R Red Station with Push & Key Reset Button FIRE PSEV-Y Yellow Station with Push & Turn Reset Button EVACUATION PSEM-R Red Station with Push & Turn Reset Button EMERGENCY PUSH BUTTON STATION WITH SOUNDER COVER (Shown At Bottom) PSFISC-R Red Station with Push & Key Reset Button & Sounder Cover FIRE PSEVSC-Y Yellow Station with Push & Turn Reset Button & Sounder Cover EVACUATION PSEMSC-R Red Station with Push & Turn Reset Button & Sounder Cover EMERGENCY Note: Other colors and text available upon request.

6 PUSH BUTTON STATIONS (PS SERIES) Push button activation twist and pull to reset Key lock mechanism is used to reset after activation Optional cover (shown in photo) protects against vandalism by sounding a low db localized alarm when cover is lifted. SPECIFICATIONS Net Weight: 3.3 lbs. 1.5 kg Shipping Weight: 4.2 lbs kg Depth without Cover: 2.0" 50.8mm with Cover: 2.4" 61mm Width without Cover: 3.25" 82.6mm with Cover: 5.5" 139.7mm Height without Cover: 4.9" 124.5mm with Cover: 8.4" 213.4mm HOW TO ORDER Specify model number Please refer to Model Number Index PS beginning on page 382 ACCESSORIES Description Cover Only, Fire, Red Cover Only, Evacuation, Yellow Cover Only, Emergency, Red Contact, normally open Contact, normally closed Part Number PSCF-R PSCE-Y PSCE-R K229277A K229277A Federal Signal Dr., University Park, IL Tel: Fax:

7 FEDERAL SIGNAL CORPORATION Uninterruptible Power Systems Model PSU Series A UPS FOR EVERY INDUSTRIAL APPLICATION Provides steady regulated voltage to /-3% 100% power conditioning Seamless switching to battery back up Output voltage 120/240VAC Available in 120VAC, 208VAC and 240VAC Floor standing or optional rack mount Available with 30 or 60 minute battery Federal Signal Uninterruptible Power Systems provide a clean and constant, regulated power supply in harsh electrical environments where the available power is polluted, fluctuating or unreliable. The Model PSU is available in a range of kva outputs from 1.0 to 7.5 with a choice of battery life of thirty or sixty minutes. Output voltage is 120/240VAC with a choice of operating voltages from 120VAC, 208VAC and 240VAC. Each Federal Signal Uninterruptible Power System provides steady, regulated voltage to /- 3% and features and input power factor correction with less than 10% total harmonic distortion. Double magnetic conversion prevents damaging load-generated harmonics from backing up into the utility lines. System status is communicated via LED indicators and an LCD display, including input voltage, output voltage, percent of battery capacity, percent of load, percent of battery charged, system on, system on battery, low battery warning and alarm. The Federal Signal Uninterruptible Power Systems are designed to support such applications as networking, hosts/hubs, voice mail, telecommunications, industrial controls, SCADA systems, personal computers, communication closets and distributed control system. Battery Model kva Time Input Voltage Style PSU or 60 min. 120, 208 or 240VAC Floor standing or rack PSU or 60 min. 120, 208 or 240VAC Floor standing or rack PSU or 60 min. 120, 208 or 240VAC Floor standing or rack PSU or 60 min. 120, 208 or 240VAC Floor standing or rack PSU or 60 min. 120, 208 or 240VAC Floor standing or rack PSU or 60 min. 120, 208 or 240VAC Floor standing or rack PSU or 60 min. 120, 208 or 240VAC Floor standing or rack

8 UNINTERRUPTIBLE POWER SYSTEMS (PSU) Note: Dimensions and weight vary by kva and battery life requirements. Call factory for complete specifications FEATURES 1 Input Volts - Indicates the input voltage. 2 Output Volts - Indicates the output voltage. 3 Percent Load - Indicates the unit is monitoring the output load capacity relative to maximum watts. 4 Percent Battery - Indicates unit is monitoring the battery charger when UPS is on utility power. 5 Display Select - Selects one of four monitor funcitons mentioned above. The display monitors one function at a time and is selected by the "Display Select" button. 6 System On - Indicates the correct AC input voltage is present. 7 System On Battery - Indicates the UPS is on battery power accompanied by an audible alarm. The UPS may switch to battery power even when it appears there are not power outages when the UPS detects input sages and surges. 8 Low Battery - Indicates batteries are low and a total UPS shutdown is immanent. This alarm set point is user selectable from 10% - 90% of battery remaining. 9 Alarm - LED On is accompanied by an audible alarm. Alarm will clear once the condition is resolved. 10 Battery Circuit Breaker 11 AC Circuit Breaker SPECIFICATIONS Input: 120, 208 or 240VAC at 60Hz Operating Range: 10%, -40% Frequency: ± 2.5Hz Power Factor: Self Correcting to >0.95 Input Harmonics: <10% THD Spike Attenuation: 3000:1 Overload Capability: 125% for ten minutes Surge Capability: 150% of rated output HOW TO ORDER Specify operating voltage Specify kva requirement Specify battery Specify floor standing or rack mount Please refer to Model Number Index PSU beginning on page Federal Signal Dr., University Park, IL Tel: Fax:

Hazardous Location Supervised Warning Light

Hazardous Location Supervised Warning Light FEDERAL SIGNAL CORPORATION Hazardous Location Supervised Warning Light Model 154XST RUGGED DESIGN FOR USE IN HAZARDOUS LOCATIONS Available in 24VDC Four wires and supervisory diode Six dome colors 10,000-hour

More information

Vibratone Horns. Models 350 and 450

Vibratone Horns. Models 350 and 450 FEDERAL SIGNAL CORPORATION Vibratone Horns Models 350 and 450 DESIGNED FOR ROUTINE SIGNALING Range of up to 200 feet Coded or sustained tones Model 350 12, 24, 120 and 240VAC; Model 450 12, 24, 125 and

More information

5 yr. Vitalite Rotating Warning Light. Models 121 and 121A LIGHT DUTY VEHICULAR LIGHT

5 yr. Vitalite Rotating Warning Light. Models 121 and 121A LIGHT DUTY VEHICULAR LIGHT FEDERAL SIGNAL CORPORATION Vitalite Rotating Warning Light Models 121 and 121A LIGHT DUTY VEHICULAR LIGHT Available in 12VDC and 24VDC Five dome colors 121 - Magnetic mount with cigarette lighter cord

More information

Vibratone Horns. Models 350 and 450

Vibratone Horns. Models 350 and 450 FEDERAL SIGNAL CORPORATION Vibratone Horns Models 350 and 450 DESIGNED FOR ROUTINE SIGNALING Range of up to 200 feet Coded or sustained tones Model 350 12, 24, 120 and 240VAC; Model 450 12, 24, 125 and

More information

WE PROTECT HAZARDOUS ENVIRONMENTS EXPLOSION-PROOF AND HAZARDOUS LOCATION VISUAL & AUDIBLE SIGNALING PRODUCTS

WE PROTECT HAZARDOUS ENVIRONMENTS EXPLOSION-PROOF AND HAZARDOUS LOCATION VISUAL & AUDIBLE SIGNALING PRODUCTS WE PROTECT HAZARDOUS ENVIRONMENTS EXPLOSION-PROOF AND HAZARDOUS LOCATION VISUAL & AUDIBLE SIGNALING PRODUCTS 100+ YEARS Federal Signal is recognized as one of the industry s leading suppliers of safety

More information

elite Model ELN Centralized Emergency Lighting Inverter Systems 550 W to 1.5 KW Systems

elite Model ELN Centralized Emergency Lighting Inverter Systems 550 W to 1.5 KW Systems 5/25/16 rev 6 elite Model ELN General Specification 550 W to 1.5 KW elite Model ELN Centralized Emergency Lighting Inverter Systems 550 W to 1.5 KW Systems 1.0 General General Specification This specification

More information

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW 12/23/16 Rev 9 UltraLITE Model ELU General Specification 4.2 KW to 5 KW UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW 1.0 General General Specification This specification describes

More information

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev AL802ULADA NAC Power Extender Installation Guide (See Application Guide for additional information) Rev. 031703 Overview: The Altronix AL802ULADA is an extremely cost effective 8 amp voltage regulated

More information

SAFEPATH Mass Notification System (SPMNS)

SAFEPATH Mass Notification System (SPMNS) Supersedes February 2016 SAFEPATH Mass Notification System (SPMNS) SP40S SPB-320 SPB-80/4 SPB-160 PS-8-LP SPMNS-MIC SP4Z-A/B Contents Page SPMNS.... 2-4 SPMNS-MIC...3 Expansion Options SAFEPATH 2-zone

More information

SP40S-D. Kingfisher Company, inc. Features: Description:

SP40S-D. Kingfisher Company, inc. Features: Description: Kingfisher Company, inc. SP40S-D Features: Multi-use applications The system can function as an evacuation system, an emergency messaging system, and an employee notification system Fire code applications

More information

LifeAlarm Fire Alarm Controls

LifeAlarm Fire Alarm Controls UL, ULC Approved* LifeAlarm Fire Alarm Controls 4009 IDNet NAC Extender for Control with IDNet Communications or Conventional NACs Features Provides additional notification appliance circuit (NAC) capacity

More information

AL800ULADA. NAC Power Extender. Installation Guide

AL800ULADA. NAC Power Extender. Installation Guide AL800ULADA NAC Power Extender Installation Guide Rev. 122000 AL800ULADA - NAC Power Extender Overview: The Altronix AL800ULADA is an extremely cost effective 8 amp voltage regulated remote power supply/battery

More information

Model AV1LED Audio-Visual LED Light Installation and Maintenance Manual

Model AV1LED Audio-Visual LED Light Installation and Maintenance Manual Model AV1LED Audio-Visual LED Light Installation and Maintenance Manual 2561528A REV. A 810 Printed in U.S.A. Warranty Seller warrants all goods for five years on parts and 2-1/2 years on labor, under

More information

POWERPATH PS-8 (105531) PS-8E (100263) PS-6 (105530) PS-6E (100262)

POWERPATH PS-8 (105531) PS-8E (100263) PS-6 (105530) PS-6E (100262) PATH PS-8 (105531) PS-8E (100263) PS-6 (105530) PS-6E (100262) NAC ETENDER SUPPLIES Installation Instructions 273 Branchport Avenue, Long Branch, NJ 07740-6899 Ph: (800) 631-2148 Fax: (732) 222-8707 Web

More information

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev Installation Guide for AL800UL-ADA NAC Power Extender Rev. 090500 Overview: The Altronix AL800UL-ADA is an extremely cost effective 8 amps voltage regulated remote power supply /battery charger. The AL800UL-ADA

More information

TrueAlert Multi-Candela Notification Appliances

TrueAlert Multi-Candela Notification Appliances TrueAlert Multi-Candela Notification Appliances UL, ULC, CSFM Listed; FM Approved* Features 24 VDC high intensity notification appliance common features: Xenon strobe with intensity selectable as 135,

More information

MODELS ASHP, ASHH, ASUP, and ASUH

MODELS ASHP, ASHH, ASUP, and ASUH 2562229A REV. A 1210 Printed in U.S.A. MODELS ASHP, ASHH, ASUP, and ASUH INSTALLATION AND SERVICE INSTRUCTIONS blank page INSTALLATION AND SERVICE INSTRUCTIONS FOR MODELS ASHP, ASHH, ASUP, AND ASUH SAFETY

More information

The Signal Is Clear TM

The Signal Is Clear TM P r o t e c t i n g y o u r b u s i n e s s The Signal Is Clear TM Federal Signal Hazardous Area Signaling Audible HORNS Corrosive atmospheres hazardous areas high noise extreme, temperatures dust humidity.

More information

AND ARCHITECT SPECIFICATIONS

AND ARCHITECT SPECIFICATIONS SXL Conventional Zone Fire Alarm Control Panel ENGINEER AND ARCHITECT SPECIFICATIONS 4 Zones Expandable to 8 Zones Microprocessor Based Control Factory Programmed Field Configurable 2 Style Y Notification

More information

TrueAlert Notification Appliances

TrueAlert Notification Appliances TrueAlert Notification Appliances UL Listed; FM, CSFM and MEA (NYC) Approved* Non-Addressable Audible/Visible Notification Appliances with SmartSync Operation of Strobes and Horns Features Wall mount audible/visible

More information

Model LTN-3R Outdoor Rated Uninterruptible Power System Single Phase

Model LTN-3R Outdoor Rated Uninterruptible Power System Single Phase Model LTN-3R Outdoor Rated Uninterruptible Power System Single Phase General Specification 550 VA/Watts 1300 VA/Watts 1.0 GENERAL This specification defines the electrical and mechanical characteristics

More information

DETCON MODEL AV1/AV2-C1D2M Hazardous Duty Class I. Div 2, Multitone Alarm Station

DETCON MODEL AV1/AV2-C1D2M Hazardous Duty Class I. Div 2, Multitone Alarm Station DETCON MODEL AV1/AV2-C1D2M Hazardous Duty Class I. Div 2, Multitone Alarm Station Operator s Installation and Instruction Manual DETCON, Inc. 3200 Research Forest Dr, The Woodlands, Texas 77387 Ph.281.367.4100

More information

MODELS 304GC, 304GCX, 314GC, and 314GCX

MODELS 304GC, 304GCX, 314GC, and 314GCX 2562109A REV. A1 0317 Printed in U.S.A. MODELS 304GC, 304GCX, 314GC, and 314GCX INSTALLATION AND SERVICE INSTRUCTIONS FOR SELECTONE Limited Warranty This product is subject to and covered by a limited

More information

TrueCom. Building Communications Systems 5115-Series , Area of Rescue Communications System. Description

TrueCom. Building Communications Systems 5115-Series , Area of Rescue Communications System. Description TrueCom Building Communications Systems 5115-Series 5115-9001, -9002 Area of Rescue Communications System Description The Simplex 5115-9001 and -9002 Area of Rescue Communications System provides buildings

More information

Pilot devices Stacklights Signal beacons

Pilot devices Stacklights Signal beacons Pilot devices Fast mounting of signal elements using bayonet fixing Easy changing of bulbs for each module without tools Up to 10 light elements possible with 2-sided mounting bracket Flexibility of signal

More information

ELECTRONIC SOUNDER STROBE Model : AVD-C407

ELECTRONIC SOUNDER STROBE Model : AVD-C407 ELECTRONIC SOUNDER STROBE Model : AVD-C407 MULTRON range of combination Electronic Sounders with Strobe Lights are designed to complement our Fire Alarm products both technically and aesthetically as an

More information

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum. September 29, 1997 Firecycle III 433 a 1. PRODUCT NAME VIKING Model E-1 Manufactured 1997 Present 2. MANUFACTURED FOR THE VIKING CORPORATION 210 N Industrial Park Road Hastings, Michigan 49058, U.S.A.

More information

Potter Wall Mount Select-A-Strobe

Potter Wall Mount Select-A-Strobe 104 Kenran Industrial Dr. Potter Wall Mount Select-A-Strobe SL-1224 SERIES SELECT-A-STROBE Call for additional listings 12 VDC with 15, 35 or 60 cd setting 24 VDC with 15, 35, 60, 5, 95 or 110 6 distinct

More information

SIRENS PROGRAMMABLE MULTI-SOUND SIGNAL by Tomar Electronics

SIRENS PROGRAMMABLE MULTI-SOUND SIGNAL by Tomar Electronics by Tomar Electronics SIRENS POWER ALARM PROGRAMMABLE MULTI-SOUND INDUSTRIAL SIGNALS The POWER ALARM siren is a heavy duty industrial audible alarm designed to operate under adverse industrial conditions

More information

Installation Instructions for 116DEGEX-FJ-(R) AdaptaBeacon Fire Alarm Strobe Lights for Use in Hazardous Locations

Installation Instructions for 116DEGEX-FJ-(R) AdaptaBeacon Fire Alarm Strobe Lights for Use in Hazardous Locations Installation Instructions for 116DEGEX-FJ-(R) AdaptaBeacon Fire Alarm Strobe Lights for Use in Hazardous Locations CEILING 116EX-C 3/ CONDUIT ENTRIES PENDANT 116EX-P 3/ CONDUIT ENTRY 116EX-C (WALL MOUNTED)

More information

TECHNICAL DATA OBSOLETE

TECHNICAL DATA OBSOLETE Deluge Devices 270a 1. PRODUCT NAME VIKING PAR-3 Available since 1991 2. MANUFACTURED FOR: THE VIKING CORPORATION 210 N. Industrial Park Road Hastings, Michigan 49058 U.S.A. Telephone: (269) 945-9501 (877)

More information

MODEL KP-200 VANDAL RESISTANT & WEATHERPROOF FLUSH MOUNT DIGITAL KEYPAD DESIGNED FOR ACCESS CONTROL APPLICATIONS

MODEL KP-200 VANDAL RESISTANT & WEATHERPROOF FLUSH MOUNT DIGITAL KEYPAD DESIGNED FOR ACCESS CONTROL APPLICATIONS MODEL KP-200 VANDAL RESISTANT & WEATHERPROOF FLUSH MOUNT DIGITAL KEYPAD DESIGNED FOR ACCESS CONTROL APPLICATIONS OPERATES ON 12 OR 24 VOLTS AC/DC, AUTO VOLTAGE SENSING FULLY PROGRAMMABLE FROM THE KEYPAD

More information

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906 s Data Sheet Fire Safety & Security Products SXL-EX Fire Alarm Control Panel Conventional Zone Fire Alarm Control Panel ARCHITECT AND ENGINEER SPECIFICATIONS Four (4) zones expandable to eight (8) zones

More information

SELECT-A-HORN/STROBE SERIES

SELECT-A-HORN/STROBE SERIES SELECT-A-HORN/STROBE SERIES Features Description Mircom s Select-A-Strobe/Horn Series is designed to comply with the Americans with Disability Act (ADA) and meet UL standard 1971 requirements for emergency

More information

Float Battery Chargers Unfiltered SCR and Filtered SCRF Series Single Phase Input / Three Phase Input

Float Battery Chargers Unfiltered SCR and Filtered SCRF Series Single Phase Input / Three Phase Input Float Battery Chargers Unfiltered SCR and Filtered SCRF Series Single Phase Input / Three Phase Input April 2006 SCR-SCRF Utility & General Industry Switchgear Alarm Systems Engine Starting Railroad Emergency

More information

Autonomous control unit

Autonomous control unit Supersedes October 2016 Autonomous control unit Description Eaton s Autonomous Control Unit (), part of the ALERiTY integrated MNS platform, is a supervised in-building emergency communications system

More information

AL600ULADA. NAC Power Extender. Installation Guide

AL600ULADA. NAC Power Extender. Installation Guide AL600ULADA NAC Power Extender Installation Guide Rev. 122000 AL600ULADA - NAC Power Extender Overview: The Altronix AL600ULADA is an extremely cost effective 6.5 amp voltage regulated remote power supply/battery

More information

Specification/ Data Sheet

Specification/ Data Sheet Specification/ Data Sheet TRITON RP Agent Release Control Panel FEATURES Agent Release Control Panel designed specifically for suppression release operation with: Four initiating device circuits (IDCs)

More information

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION IBAS LIGHTING CONTROL

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION IBAS LIGHTING CONTROL PART 0 A/E INSTRUCTIONS 0.01 DESIGN REQUIREMENTS A. Minimum lighting control (base scope of work) shall include all corridors. The lighting in all the corridors shall be turned on (if not already on) if

More information

WARNING WARNING. Installation Instructions for 116DEXSTC-FJ AdaptaBeacon Fire Alarm Strobe Lights for Use in Hazardous Locations.

WARNING WARNING. Installation Instructions for 116DEXSTC-FJ AdaptaBeacon Fire Alarm Strobe Lights for Use in Hazardous Locations. Cheshire, CT 064 3-699-30 (Ph) 3-699-3365 (Cust. Serv. Fax) 3-699-78 (Tech. Serv. Fax) Installation Instructions for 116DEXSTC-FJ AdaptaBeacon Fire Alarm Strobe Lights for Use in Hazardous Locations STANCHION

More information

08 Series Notification Appliances AS / AH & AS Audible Strobe Appliances and AH Audibles Application: Indoor / Outdoor

08 Series Notification Appliances AS / AH & AS Audible Strobe Appliances and AH Audibles Application: Indoor / Outdoor s Data Sheet Fire Safety & Security Products 08 Series Notification Appliances AS / AH & AS Audible Strobe Appliances and AH Audibles Application: Indoor / Outdoor AS-MC-CW AS-MC-R AH-W AH-R Product Overview

More information

SAFEPATH DoD facility communications system & expansion options

SAFEPATH DoD facility communications system & expansion options Supersedes September 2011 SAFEPATH DoD facility communications system & expansion options SP40S-D SPB-320 SPB-80/4 SPB-160 SP4-TZC SPRM SP4Z-A/B SP-SVC Contents Description Page SP40S-D Communications

More information

Installation and Maintenance Manual. Model 154XST Series Strobe Light for Use in Hazardous Conditions. français...page 21 español...

Installation and Maintenance Manual. Model 154XST Series Strobe Light for Use in Hazardous Conditions. français...page 21 español... Model 154XST Series Strobe Light for Use in Hazardous Conditions Installation and Maintenance Manual 2561762C Rev. C0 913 Printed in U.S.A. français...page 21 español...página 43 Warranty Seller warrants

More information

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information)

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) AL802ULADA NAC Power Extender Installation Guide (See Application Guide for additional information) Rev. 042010 Agency Listings: UL Listed Control Units for Fire Protective Signaling Systems (UL 864).

More information

DETCON MODEL AV2-C1D2C Hazardous Duty Class I. Div 2, Continuous Tone Alarm Station

DETCON MODEL AV2-C1D2C Hazardous Duty Class I. Div 2, Continuous Tone Alarm Station DETCON MODEL AV2-C1D2C Hazardous Duty Class I. Div 2, Continuous Tone Alarm Station Operator s Installation and Instruction Manual DETCON, Inc. 3200 Research Forest Dr., The Woodlands, Texas 77387 Ph.281.367.4100

More information

s Notification Appliances

s Notification Appliances s Notification Appliances Data Sheet Fire Safety Products AS & AH Audible Horn Strobe / Audible Horn Appliances Application: Indoor / Outdoor AS-MC-CW AS-MC-R AH-R AH-W Product Overview Fast installation

More information

SelecTone Wall Mounted Command Unit

SelecTone Wall Mounted Command Unit FEDERAL SIGNAL CORPORATION SelecTone Wall Mounted Command Unit Model 300SCW-1 DESIGNED FOR SELECTONE SYSTEMS Produces four prioritized tone signals and public address Remote microphone input Multi-voltage

More information

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS. NXM Series - Survive-All. Emergency Light Unit

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS. NXM Series - Survive-All. Emergency Light Unit Emergency Light Unit IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following: READ AND FOLLOW ALL SAFETY INSTRUCTIONS 1. Do not

More information

UltraLITE MODEL ELU. Centralized Emergency Lighting Inverters

UltraLITE MODEL ELU. Centralized Emergency Lighting Inverters 1.5 kw 10 kw SINGLE PHASE UltraLITE MODEL ELU Centralized Emergency Lighting Inverters Seamless transfer, online double-conversion system, compatible with all existing lighting applications. Meets NFPA

More information

SAFEPATH SAFEPATH. Emergency communications system

SAFEPATH SAFEPATH. Emergency communications system SAFEPATH SAFEPATH Emergency communications system ALERiTY Integrated mass notification solutions by Eaton; designed to protect, alert and inform your most critical resources your people ALERiTY /a ler

More information

SECTION COMMERCIAL DOOR OPERATORS OVERHEAD RSX FIRE DOOR OPERATOR

SECTION COMMERCIAL DOOR OPERATORS OVERHEAD RSX FIRE DOOR OPERATOR SECTION 08734 COMMERCIAL DOOR OPERATORS OVERHEAD RSX FIRE DOOR OPERATOR Display hidden notes to specifier by using Tools / Options / View / Hidden Text. PART 1 GENERAL 1.1 SECTION INCLUDES A. Overhead

More information

GENERAL STANDARD FEATURES. ISO-9001 Engineering and Manufacturing Quality System Certified to International Standard ISO-9001 PATENT PENDING

GENERAL STANDARD FEATURES. ISO-9001 Engineering and Manufacturing Quality System Certified to International Standard ISO-9001 PATENT PENDING GENERAL The VEC 25/50 is a state-of-the-art, compact, stand-alone or slave Emergency Voice Evacuation Control. The VEC 25/50 is offered in a self-contained, cost-effective design and includes a 25 Watt,

More information

Addressable Fire Alarm Control Panel

Addressable Fire Alarm Control Panel PRODUCT SPECIFICATION XR2400F Addressable FACP Addressable Fire Alarm Control Panel Description The DMP XR2400F Addressable Fire Alarm Control Panel is an expandable Fire Alarm Control with built-in DACT

More information

ECC-50/100(E) Emergency Command Center. General. Features. Emergency Voice Evacuation TYPICAL APPLICATIONS

ECC-50/100(E) Emergency Command Center. General. Features. Emergency Voice Evacuation TYPICAL APPLICATIONS ECC-50/100(E) Emergency Command Center DF-60734:A4 General Firelite s ECC-50/100 and ECC-50/100E are multipurpose emergency voice evacuation panels for fire applications, mass notification applications,

More information

APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES

APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES POWER SUPPLY AND BATTERY CHARGER AC AND DC STATUS INDICATORS ENOUGH POWER TO SUPPORT UP TO 3 MAGLOCKS OR ELECTRIC STRIKES PLUS REQUIRED

More information

ORENA BRAND CONVENTIONAL (ORENA Brand) CE

ORENA BRAND CONVENTIONAL (ORENA Brand) CE ORENA BRAND CONVENTIONAL (ORENA Brand) CE ODH02E 2 Zone Conventional Control Panel Zone Capacity: can be connected with 20 fire detectors and infinite manual call points Using environment: Temperature:

More information

SCR/SCRF SERIES. Industry s First Choice for Time-Tested Proven Reliability FLOAT BATTERY CHARGERS. Single-Phase Input

SCR/SCRF SERIES. Industry s First Choice for Time-Tested Proven Reliability FLOAT BATTERY CHARGERS. Single-Phase Input SCR/SCRF SERIES FLOAT BATTERY CHARGERS Industry s First Choice for Time-Tested Proven Reliability Single-Phase Input Three-Phase Input Applications for: Utility & General Industry Switchgear Engine starting

More information

Model PAD-3 Distributed Power Module NAC Expander Installation, Operation, and Maintenance Manual

Model PAD-3 Distributed Power Module NAC Expander Installation, Operation, and Maintenance Manual Fire Safety Model PAD-3 Distributed Power Module NAC Expander Installation, Operation, and Maintenance Manual Siemens Building Technologies, Inc. Siemens Building Technologies, Ltd. 8 Fernwood Road 2 Kenview

More information

ACC-25/50ZST. Zoned System Voice with Telephone Evacuation Control Panel

ACC-25/50ZST. Zoned System Voice with Telephone Evacuation Control Panel ACC-25/50ZST Zoned System Voice with Telephone Evacuation Control Panel General The AUDIO COMMAND CENTER 25/50 Zone System with FireFighters Telephone (ACC-25/50ZST) is a state-of-the-art Emergency Voice

More information

MODEL AV2-C1D1M Hazardous Duty Class I. Div 1, Multitone Alarm Station

MODEL AV2-C1D1M Hazardous Duty Class I. Div 1, Multitone Alarm Station MODEL AV2-C1D1M Hazardous Duty Class I. Div 1, Multitone Alarm Station Operator s Installation and Instruction Manual DETCON, Inc. 3200 Research Forest Dr., The Woodlands, Texas 77387 Ph.281.367.4100 /

More information

FLOAT BATTERY CHARGERS

FLOAT BATTERY CHARGERS FLOAT BATTERY CHARGERS UNFILTERED SCR SERIES FILTERED SCRF SERIES SINGLE PHASE INPUT THREE PHASE INPUT Applications for: UTILITY & GENERAL INDUSTRY Switchgear Engine Starting Emergency Lighting Alarm Systems

More information

Pilfergard Door Alarms

Pilfergard Door Alarms Alarm Lock PilFergard Door Alarms Pilfergard Door Alarms A PG10 Pilfergard model PG10 exit door alarm designed to deter the use of the secured door by sounding a twin action alarm when opened by unauthorized

More information

ECC-50/100C. Emergency Command Center

ECC-50/100C. Emergency Command Center ECC-50/100C Emergency Command Center Canadian DF-60815:B Emergency Communications General Fire-lite s ECC-50/100C is a multipurpose emergency voice evacuation panel for fire applications, mass notification

More information

C1D1 Explosion Proof Horn - Industrial Siren - Programmable Timer - NEMA 4X - Weatherproof

C1D1 Explosion Proof Horn - Industrial Siren - Programmable Timer - NEMA 4X - Weatherproof C1D1 Explosion Proof Horn - Industrial Siren - Programmable Timer - NEMA 4X - Weatherproof Part #: EPSN-HRN-PA-AT-MOD1 Made in the USA The Larson Electronics EPSN-HRN-PA-AT-MOD1 Explosion Proof Horn provides

More information

TrueAlert Addressable Notification Appliances

TrueAlert Addressable Notification Appliances UL, ULC Listed* TrueAlert Addressable Notification Appliances Audible/Visible Notification Appliances; Multi-Tone Horn/Strobe with 520 Hz Output Features Individually addressed and controlled multi-tone

More information

SCR/SCRF SERIES. Industry s First Choice for Time-Tested Proven Reliability FLOAT BATTERY CHARGERS. Single-Phase Input

SCR/SCRF SERIES. Industry s First Choice for Time-Tested Proven Reliability FLOAT BATTERY CHARGERS. Single-Phase Input SCR/SCRF SERIES FLOAT BATTERY CHARGERS Industry s First Choice for Time-Tested Proven Reliability Single-Phase Input Three-Phase Input Applications for: Utility & General Industry Switchgear Engine starting

More information

July 14, 1999 DF C-100.

July 14, 1999 DF C-100. www.firelite.com GENERAL The Fire Lite FIRE COMMAND 25/50 is a state-of-theart, compact, stand-alone or slave Emergency Voice Evacuation Control Panel (VECP). The FIRE COMMAND 25/50 is offered in a self-contained,

More information

Series M22 Signaling Beacons and Alarms

Series M22 Signaling Beacons and Alarms Series M22 Beacons and Alarms Signaling S I G N A L G E R Ä T E Signaling Solutions Loud and Clear M22 Panel Mount Signaling Beacons and Alarms from the Auer company are the perfect compliment to Sprecher

More information

Conventional Releasing Control Panel

Conventional Releasing Control Panel s Data Sheet Fire Safety Products Conventional Releasing Control Panel Pre-Action Deluge Agent-Releasing Fire System Model TXR-320 Remote configurable Up to two (2) hazard areas Operable with the following:

More information

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM SECTION 283111 - DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

Revision: None DCN No. First Issue Date: November 30, 1998 Product: Standard DCT, 120-volts

Revision: None DCN No. First Issue Date: November 30, 1998 Product: Standard DCT, 120-volts Figure 1Document: SPEC-112 Revision: None DCN No. First Issue Date: November 30, 1998 Product: Standard DCT, 120-volts construction requirements of UL approved Class H (180 C) insulation system. Transformers

More information

DGC-500 DIGITAL GENSET CONTROLLER

DGC-500 DIGITAL GENSET CONTROLLER DGC-500 DIGITAL GENSET CONTROLLER Basler Electric s Digital Genset Controller (DGC-500) offers a low cost microprocessor based integrated alternative for the control and monitoring of small to medium sized

More information

DGC-1000 DIGITAL GENSET CONTROLLER

DGC-1000 DIGITAL GENSET CONTROLLER DGC-1000 DIGITAL GENSET CONTROLLER Basler Electric s Digital Genset Controller (DGC-1000) offers a low cost microprocessor based integrated alternative for small to medium sized genset control and monitoring.

More information

Genesis Low Frequency (520 Hz) Horn-Strobe Installation Sheet

Genesis Low Frequency (520 Hz) Horn-Strobe Installation Sheet Genesis Low Frequency (520 Hz) Horn-Strobe Installation Sheet Table 1: Models Description Low frequency (520 Hz) horn, white housing, no FIRE marking, standard output clear strobe light Low frequency (520

More information

Field Configurable Horns and Strobes

Field Configurable Horns and Strobes EDWARDS Catalog u Strobes, Horns, Bells, Chimes LIFE SAFETY & INCIDENT MANAGEMENT Field Configurable Horns and Strobes Genesis Series ECS/MNS appliances available with clear or amber lenses. S218, S5389,

More information

16.34 Multiplex Fire Alarm System Construction Standards Page 1 of 5

16.34 Multiplex Fire Alarm System Construction Standards Page 1 of 5 Construction Standards Page 1 of 5.1 General Description.1 The University requires that all new fire alarm system control panel, components, and devices, as required for the project, be Secutron 2900 Series

More information

Centro-Matic Automated Lubrication Systems System Controls

Centro-Matic Automated Lubrication Systems System Controls Selecting the right controls for your automated lubrication system is one of the last steps in the design process. Several different models may be chosen to control power-operated pumps, depending on the

More information

LF-4000 Series Conventional Fire Alarm Control Unit

LF-4000 Series Conventional Fire Alarm Control Unit LF-4000 Series Conventional Fire Alarm Control Unit Features: 1 to 36 Zone Control Panels Control Key Switch Easy Push Button Control Switches Zone Circuit Monitoring for Open and Short Sounder Circuit

More information

LORAIN CIP 4890/48120 DC Power System

LORAIN CIP 4890/48120 DC Power System DC Power for Business-Critical Continuity Key Features Compact flexibility provides rectifiers, distribution, and controller in one shelf Constant power delivers more current at lower voltages to meet

More information

WFDE Series Waterflow Detector

WFDE Series Waterflow Detector WFDE Series Waterflow Detector The System Sensor WFDE series is compatible with pipe diameters ranging from 50mm through 200mm and can be mounted in a vertical or horizontal position. Features Compliant

More information

_5120_School_Intercom_Rack_Spec.doc 09/21/04

_5120_School_Intercom_Rack_Spec.doc 09/21/04 ****************************************************************************************** 16720-3 Simplex TrueCom 5120 Inter Communication System Advanced 360 Station, Rack Mounted, Intercom / Paging

More information

Genesis LED G1 Series

Genesis LED G1 Series EDWARDS Catalog u Strobes, Horns, Bells, Chimes LIFE SAFETY INCIDENT MANAGEMENT Genesis LED G1 Series Compact Notification Devices S218, S5389 7125-1657:0506 7135-1657:0502 Overview Genesis LED G1 Series

More information

11:00 to 12:00 Secrets to achieving code-compliant strobe installations. Ralph Coco, Potter Canada Paul Jewett, Mircom Group of Companies

11:00 to 12:00 Secrets to achieving code-compliant strobe installations. Ralph Coco, Potter Canada Paul Jewett, Mircom Group of Companies 11:00 to 12:00 Secrets to achieving code-compliant strobe installations. Ralph Coco, Potter Canada Paul Jewett, Mircom Group of Companies Visible Signals Agenda 1. Physics 2. Installation Considerations

More information

Bulletin 855T 70 mm Control Tower Stack Lights

Bulletin 855T 70 mm Control Tower Stack Lights Bulletin 855T 70 mm Control Tower Stack Lights Light Modules Red Flashing Incandescent (Black Housing) 855T B 10 FN 4 a b c d a b c d Housing Color Voltage Light Module Type Lens Color Code Description

More information

Signature Series Auto-Sync Output Module (CC1S)

Signature Series Auto-Sync Output Module (CC1S) Signature Series Auto-Sync Output Module (CC1S) Product description Mounting The Signature Series can be mounted in a North American 2-1/2 in (64 mm) deep 2-gang box or a standard 4 in square box 1-1/2

More information

TrueAlert Addressable Notification Appliances

TrueAlert Addressable Notification Appliances UL, ULC, CSFM Listed, FM Approved TrueAlert Addressable Notification Appliances Audible/Visible Notification Appliances, Wall Mount Multi-Candela Horn/Strobe, Model Series 49AV Features Individually addressed

More information

Yodalarm. Sounders. Pg Y03 Y04/YL4 Y05/YL5 Y08/YL8/Y08 SUPER/ YL8 SUPER V4 V6/Y06/YL6 Carillon

Yodalarm. Sounders. Pg Y03 Y04/YL4 Y05/YL5 Y08/YL8/Y08 SUPER/ YL8 SUPER V4 V6/Y06/YL6 Carillon Sounders Y03 Y04/YL4 Y05/YL5 Y08/YL8/Y08 SUPER/ YL8 SUPER V4 V6/Y06/YL6 Carillon Pg 185 186 187 188 189 190 191 Y03 1YA030207 1YA030203 1YA030205 YL030/24 A1:2002 YL030110/230 UL464 C22.2 No. M1983 BS

More information

Explosion Proof Light Watt Metal Halide - Class 1 Div 1 & Class 2 Div 1

Explosion Proof Light Watt Metal Halide - Class 1 Div 1 & Class 2 Div 1 Explosion Proof Light - 400 Watt Metal Halide - Class 1 Div 1 & Class 2 Div 1 Part #: EPL-HB-400W-MH Made in the USA The EPL-HB-400W-MH metal halide, hazardous area light fixture from Larson Electronics

More information

Installation Guide for AL400ULM. Multi-Output Access Control Power Supply Charger

Installation Guide for AL400ULM. Multi-Output Access Control Power Supply Charger Installation Guide for AL400ULM Multi-Output Access Control Power Supply Charger R AL400ULM - Multi-Output Access Control Power Supply/Charger Rev. 072500 Overview: The AL400ULM multi-output access control

More information

MAX ARM. Heavy Duty Linear Actuator for Residential / Commercial use. Super quiet Solar ready Large diameter stainless steel output shaft

MAX ARM. Heavy Duty Linear Actuator for Residential / Commercial use. Super quiet Solar ready Large diameter stainless steel output shaft MAX ARM Heavy Duty Linear Actuator for Residential / Commercial use Super quiet Solar ready Large diameter stainless steel output shaft MAX AC control box DSP Control 2 Years Warranty or 100,000 Cycles

More information

RAPID RESPONSE Model RCP-1 Residential Control Panel 1 or 1-1/2 Inch (DN25 or DN40), 175 psi (12,1 bar) General Description.

RAPID RESPONSE Model RCP-1 Residential Control Panel 1 or 1-1/2 Inch (DN25 or DN40), 175 psi (12,1 bar) General Description. Worldwide Contacts www.tyco-fire.com RAPID RESPONSE Model RCP-1 Residential Control Panel 1 or 1-1/2 Inch (DN25 or DN40), 175 psi (12,1 bar) General Description The TYCO RAPID RESPONSE Model RCP-1 Residential

More information

AL1002ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev X

AL1002ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev X AL1002ULADA NAC Power Extender Installation Guide (See Application Guide for additional information) Rev. 071508X Agency Listings: UL Listed Control Units for Fire Protective Signaling Systems (UL 864).

More information

Life safety notification

Life safety notification LED Wheelock Exceder LED3 Life safety notification Meeting the latest codes with increased energy-efficiency in a compact design Wheelock Exceder LED3 Compliant, compatible, compact, and energy efficient

More information

INSTALLATION MANUAL PC56O. Version 1.OA

INSTALLATION MANUAL PC56O. Version 1.OA INSTALLATION MANUAL PC56O Version 1.OA TABLE OF CONTENTS INTRODUCTION 3 Features... 3 Specifications... 3 INSTALLATION 4 Mounting the Control Panel... 4 Mounting the Keypad... 4 Wiring... 5 Burglary Zone

More information

Litestak Status Indicator

Litestak Status Indicator FEDERAL SIGNAL ORPORATION Litestak Status Indicator Models LS and LSL NOTIFY STATUS HANGES WITH OLOR AND SOUND Available in 4VD, 0VA and 40VA Five lens colors Surface mount and integrated /4-inch pipe

More information

SOLID PLUS HEAT

SOLID PLUS HEAT SOLID PLUS HEAT WWW.ROTAID.COM PRODUCT SHEET The Rotaid Solid Plus Heat is a highly robust and durable AED wall cabinet that ensures a recognizable, solid and sustainable storage of your AED device in

More information

Field Configurable Horns and Strobes

Field Configurable Horns and Strobes Vigilant Catalog Strobes, Horns, Bells, Chimes Field Configurable Horns and Strobes Genesis Series MNEC appliances available with clear or amber lenses. Pending Overview The Genesis line of fire alarm

More information

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev Installation Guide for AL600ULM Multi-Output Access Control Power Supply Charger Rev. 091800 1 AL600ULM - Multi-Output Access Control Power Supply/Charger Overview: The AL600ULM multi-output access control

More information

Class 1 Division 2 Hazardous Location Stack Light - Signal Traffic Light - Multiple Lamp Colors

Class 1 Division 2 Hazardous Location Stack Light - Signal Traffic Light - Multiple Lamp Colors Class 1 Division 2 Hazardous Location Stack Light - Signal Traffic Light - Multiple Lamp Colors Part #: HAL-TL-4X10W-C-PA Made in the USA The HAL-TL-4X10W-C-PA Class 1 Division 2 LED Stack Light with Signal

More information

Soft Start Series MP700 Solid State, Reduced Voltage

Soft Start Series MP700 Solid State, Reduced Voltage Metron Fire Pump Controls and Accessories Soft Start Series MP700 Solid State, Reduced Voltage Metron Fire Pump Controllers conform to the latest requirements of National Fire Protection Association s

More information