Schedule of Accreditation issued by United Kingdom Accreditation Service High Street, Feltham, Middlesex, TW13 4UN, UK

Size: px
Start display at page:

Download "Schedule of Accreditation issued by United Kingdom Accreditation Service High Street, Feltham, Middlesex, TW13 4UN, UK"

Transcription

1 Wira House West Park Ring Road Leeds LS16 6QL Contact: Dr P Hamlyn Tel: +44 (0) Fax: +44 (0) info@bttg.co.uk Website: Testing performed by the comprising the laboratories specified in the Appendix SUMMARY OF ACCREDITATION CHEMICALS & CHEMICAL PRODUCTS Organic chemicals & products Chemical & physical Paints, varnishes, pigments & dyes Colour comparison/determination/ difference CONSTRUCTION Fire resistance & protection, reaction to fire Building components & materials Geotextiles, flexible sheet materials & liners Material properties Road signs Reflectivity Sports & playground surfaces Fire PERSONAL PROTECTIVE EQUIPMENT Body protection Body protection Eye & face protection Eye & face protection Gloves Gloves Head protection Head protection High visibility garments High visibility garments Rescue appliances Abandonment suits Constant wear suits TEXTILES, PLASTICS, RUBBER, PAPER & PACKAGING Bedcovers, pillows, continental quilts & mattresses Airflow Fillings Fire Blankets Fire Carpet Carpet, mats & floor covering Coated fabrics Coated fabrics Curtains & drapes Fire Furniture Fire Nightwear Fire Tent fabric Fire Textiles, leather & general fabrics Biological & microbiological Chemical Colour Construction Dimensions Fibre content Fire Non-woven fabric tests Physical Thermal TOYS/CHILDCARE PRODUCTS/ SPORTS & LEISURE EQUIPMENT/ WRITING INSTRUMENTS Sports & leisure equipment Sports & leisure equipment Toys & toy packaging Chemical Migration of elements Assessment Manager: BM (Test_022) Page 1 of 50

2 Testing performed by the comprising the laboratories specified in the Appendix DETAIL OF ACCREDITATION SHIRLEY TECHNOLOGIES LTD Trafford Park, Manchester FIBRES Biological Tests and related Opinions and Antibacterial properties Documented In-House Method STS 51 Evaluation of antibacterial finishes on fabrics Examination of antibacterial effect of impregnated textiles by agar diffusion test Examination of antimycotic effect of impregnated textiles by agar diffusion test Fungicides: evaluation on textiles; mildew and rot resistance of textiles Resistance of polyurethane to microbiological deterioration Resistance of textiles to microbiological deterioration Antibacterial activity assessment of textile materials: parallel streak method AATCC 100:1998 SNV :1976 and 1994 SNV :1976 and 1994 AATCC 30:1998 AATCC 30:1981 Documented In-House Method B/PU/1:1981 BS 6085:1992 AATCC 147:1998 Chemical Tests and related Opinions and Ash content BS 6646:1985(1996) Certain water- or alkali-soluble additives Conductivity, ph, water-soluble matter in aqueous extracts BS 4032:1978(1995) BS 3266:1981(1995) BS 5F 100:1991:Methods 43 to 45 and BS 6F 100:1998, Sections 4.2 to 4.4 ph of aqueous extracts BS EN 1413:1998 Assessment Manager: BM (Test_022) Page 2 of 50

3 Testing performed by the comprising the laboratories specified in the Appendix FIBRES (cont d) Chemical Tests and related Opinions and (cont d) Fluidity of cotton and certain cellulose man-made fibres BS 2610:1978(1995) Fluidity of linen materials BS 3090:1978(1995) Nitrogen content Documented In-House Method 36 (NAMAS File) Oil, fats and waxes in cotton Documented In-House Method based on BS 3477:1962(1982) Oil, fats and waxes in wool BS 3582:1981(1995) Phosphorus content Documented In-House Method 38 (NAMAS File) Preparation of samples BS 4658:1978(1996) Preservative content (BS Method) BS 2087:Part 2:1981 BS 2087:Part 2:1992 Preservative content (STS Method) A1 Quantitative analysis of fibre mixtures STS Method, Appendix 1 of Laboratory Manual BS 4407:1988(1995) excluding Method 17 Total formaldehyde BS 6806:Part 1:1987(1993) Viscosity number of polyamide ISO 307:1994 Wet ashing BS 6648:1986(1994) Determination of soluble hexavalent chromium Colour Fastness Tests and related Opinions and Artificial light: xenon arc Washing and laundering BS 6810:1987(1996) BS EN ISO 105:1999 B02 BS EN 20105:1993/BS 1006:1990 C01 - C05 Assessment Manager: BM (Test_022) Page 3 of 50

4 Testing performed by the comprising the laboratories specified in the Appendix FIBRES (cont d) Colour Fastness Tests and related Opinions and (cont d) ISO 105 Colour and colour difference J01 - J03:1997 A05:1996 Dry cleaning Bleaching agencies Wet and dry rubbing Wet and dry rubbing Photochromism Rubbing: organic solvents Aqueous agencies Atmospheric contaminants: oxides of nitrogen Aqueous agencies Weathering: xenon arc Washing and laundering Laundering using non-phosphate reference detergent BS EN ISO 105:1995 D01 N01 - N04 X12 BS EN ISO 105:X12:2003 BS EN ISO 105:1996 B05 D02 E01, E02, E04 G01 BS EN ISO 105:1997 E03, E05 - E08 B04 C06 BS ISO 105:2001 CO8 YARNS Biological Tests and related Opinions and Antibacterial properties Documented In-House Method STS 51 Evaluation of antibacterial finishes on fabrics Examination of antibacterial effect of impregnated textiles by agar diffusion test Examination of antimycotic effect of impregnated textiles by agar diffusion test Fungicides: evaluation on textiles; mildew and rot resistance of textiles AATCC 100:1998 SNV :1976 and 1994 SNV :1976 and 1994 AATCC 30:1998 AATCC 30:1981 Assessment Manager: BM (Test_022) Page 4 of 50

5 Testing performed by the comprising the laboratories specified in the Appendix YARNS (cont d) Biological Tests and related Opinions and (cont d) Resistance of polyurethane to microbiological deterioration Resistance of textiles to microbiological deterioration Antibacterial activity assessment of textile materials: parallel streak method Chemical Tests and related Opinions and Documented In-House Method B/PU/1 BS 6085:1992 AATCC 147:1998 Ash content BS 6646:1985(1996) Certain water- or alkali-soluble additives Conductivity, ph, water-soluble matter, in aqueous extracts BS 4032:1978(1995) BS 3266:1981(1995) BS 5F 100:1991:Methods 43 to 45 and BS 6F 100:1998, Sections 4.2 to 4.4 ph of aqueous extracts BS EN 1413:1998 Fluidity of cotton and certain cellulose materials BS 2610:1978(1995) Fluidity of linen materials BS 3090:1978(1995) Nitrogen content Documented In-House Method 36 (NAMAS File) Oil, fats and waxes in cotton Documented In-House Method based on BS 3477:1962(1982) Oil, fats and waxes in wool BS 3582:1981(1995) Phosphorus content Documented In-House Method 38 (NAMAS File) Preparation of samples BS 4658:1978(1996) Preservative content (BS Method) BS 2087:Part 2:1981 BS 2087:Part 2:1992 Assessment Manager: BM (Test_022) Page 5 of 50

6 Testing performed by the comprising the laboratories specified in the Appendix YARNS (cont d) Chemical Tests and related Opinions and (cont d) Preservative content (STS Method) A1 Qualitative analysis of: Binary fibre mixtures Ternary fibre mixtures Quantitative analysis of fibre mixtures STS Method, Appendix 1 of Laboratory Manual ISO 1833:1977 ISO 5088:1976 BS 4407:1988(1995) excluding Method 17 (+ Amd 9438) Total formaldehyde BS 6806:Part 1:1987(1993) Viscosity number of polyamide ISO 307:1994 Wet ashing BS 6648:1986(1994) Determination of soluble hexavalent chromium Colour Fastness Tests and related Opinions and Artificial light: xenon arc Washing and laundering BS 6810:1987(1996) BS EN ISO 105:1999 B02 BS EN 20105:1993/BS 1006:1990 C01 - C05 ISO 105 Colour and colour difference J01 - J03:1997 A05:1996 Dry cleaning Bleaching agencies Wet and dry rubbing Wet and dry rubbing Photochromism Rubbing: organic solvents Aqueous agencies Atmospheric contaminants: oxides of nitrogen BS EN ISO 105:1995 D01 N01 - N04 X12 BS EN ISO 105:X12:2003 BS EN ISO 105:1996 B05 D02 E01, E02, E04 G01 Assessment Manager: BM (Test_022) Page 6 of 50

7 Testing performed by the comprising the laboratories specified in the Appendix YARNS (cont d) FABRICS Colour Fastness Tests and related Opinions and (cont d) Aqueous agencies Weathering: xenon arc Washing and laundering Laundering using non-phosphate reference detergent Biological Tests and related Opinions and BS EN ISO 105:1997 E03, E05 - E08 B04 C06 BS ISO 105:2001 C08 Antibacterial properties Documented In-House Method STS 51 Evaluation of antibacterial finishes on fabrics Examination of antibacterial effect of impregnated textiles by agar diffusion test Examination of antimycotic effect of impregnated textiles by agar diffusion test Fungicides: evaluation on textiles; mildew and rot resistance of textiles Resistance of polyurethane to microbiological deterioration Resistance of textiles to microbiological deterioration Antibacterial activity assessment of textile materials: parallel streak method AATCC 100:1998 SNV :1976 and 1994 SNV :1976 and 1994 AATCC 30:1998 AATCC 30:1981 Documented In-House Method B/PU/1 BS 6085:1992 AATCC 147:1998 Chemical Tests and related Opinions and Ash content BS 6646:1985(1996) Certain water- or alkali-soluble additives BS 4032:1978(1995) Assessment Manager: BM (Test_022) Page 7 of 50

8 Testing performed by the comprising the laboratories specified in the Appendix FABRICS (cont d) Chemical Tests and related Opinions and (cont d) Conductivity, ph, water-soluble additives BS 3266:1981(1995) BS 5F 100:1991:Methods 43 to 45 and BS 6F 100:1998, Sections 4.2 to 44 ph of aqueous extracts BS EN 1413:1998 Degree of cure measurements Documented In-House Method 37 (NAMAS File) Fluidity of cellulose BS 2610:1978(1995) Fluidity of linen BS 3090:1978(1995) Formaldehyde, odour in resin-treated fabric by the sealed jar method BS 6806:Part 3:1987(1993) and AATCC BS EN ISO 14184:Part 2:1998 Free formaldehyde (BS Method) BS 6806:Part 2:1987(1993) Free and hydrolysed formaldehyde BS EN ISO 14184:Part 1:1998 Free formaldehyde (Japanese Law) Japanese Law Nitrogen content Documented In-House Method 36 (NAMAS File) Oil, fats and waxes in cotton Documented In-House Method based on BS 3477:1962(1982) Oil, fats and waxes in wool BS 3582:1981(1995) Phosphorus content Documented In-House Method 38 (NAMAS File) Preparation of samples BS 4658:1978(1996) Preservative content (BS Method) A1 BS 2087:Part 2:1981 BS 2087:Part 2:1992 Preservative content (STS Method) A1 Qualitative analysis of: Binary fibre mixtures Ternary fibre mixtures STS Method, Appendix 1 of Laboratory Manual ISO 1833:1977 ISO 5088:1976 Assessment Manager: BM (Test_022) Page 8 of 50

9 Testing performed by the comprising the laboratories specified in the Appendix FABRICS (cont d) Chemical Tests and related Opinions and (cont d) Quantitative analysis of fibre mixtures BS 4407:1988(1995) excluding Method 17 (+ Amd 9438) Total formaldehyde BS 6806:Part 1:1987(1993) Viscosity number of polyamide ISO 307:1994 Wet ashing BS 6648:1986(1994) Determination of soluble hexavalent chromium Colour Fastness Tests and related Opinions and Artificial light: xenon arc Washing and laundering BS 6810:1987(1996) BS EN ISO 105:1999 B02 BS EN 20105:1993/BS 1006:1990 C01 - C05 ISO 105 Colour and colour difference J01 - J03:1997 A05:1996 Dry cleaning Bleaching agencies Wet and dry rubbing Photochromism Rubbing: organic solvents Aqueous agencies Atmospheric contaminants: oxides of nitrogen Aqueous agencies Weathering: xenon arc Washing and laundering Laundering using non-phosphate reference detergent BS EN ISO 105:1995 D01 N01 - N04 X12 BS EN ISO 105:1996 B05 D02 E01, E02, E04 G01 BS EN ISO 105:1997 E03, E05 - E08 B04 C06 BS ISO 105:2001 C08 Assessment Manager: BM (Test_022) Page 9 of 50

10 Testing performed by the comprising the laboratories specified in the Appendix COATED FABRICS Biological Tests and related Opinions and Antibacterial properties Documented In-House Method STS 51 Evaluation of antibacterial finishes on fabrics Examination of antibacterial effect of impregnated textiles by agar diffusion test Examination of antimycotic effect of impregnated textiles by agar diffusion test Fungicides: evaluation on textiles; mildew and rot resistance of textiles Resistance of polyurethane to microbiological deterioration Resistance of textiles to microbiological deterioration Antibacterial activity assessment of textile materials: parallel streak method AATCC 100:1998 SNV :1976 and 1994 SNV :1976 and 1994 AATCC 30:1998 AATCC 30:1981 Documented In-House Method B/PU/1:1981 BS 6085:1992 AATCC 147:1998 Chemical Tests and related Opinions and Ash content BS 6646:1985(1996) Fluidity of cellulose BS 2610:1978(1995) Fluidity of linen BS 3090:1978(1995) Nitrogen content Documented In-House Method 36 (NAMAS File) Phosphorus content Documented In-House Method 38 (NAMAS File) Preparation of samples BS 4658:1978(1996) Preservative content (BS Method) BS 2087:Part 2:1981 BS 2087:Part 2:1992 Assessment Manager: BM (Test_022) Page 10 of 50

11 Testing performed by the comprising the laboratories specified in the Appendix COATED FABRICS (cont d) Chemical Tests and related Opinions and (cont d) Preservative content (STS Method) A1 Qualitative Analysis of: Binary fibre mixtures Ternary fibre mixtures Quantitative analysis of fibre mixtures STS Method, Appendix 1 of Laboratory Manual ISO 1833:1977 ISO 5088:1976 BS 4407:1988(1995) excluding Method 17 (+ Amd 9438) Total formaldehyde BS 6806:Part 1:1987(1993) Viscosity number of polyamide ISO 307:1994 Wet ashing BS 6648:1986(1994) Colour Fastness Tests and related Opinions and Artificial light: xenon arc Washing and laundering BS EN ISO 105:1999 B02 BS EN 20105:1993/BS 1006:1990 C01 - C05 ISO 105 Colour and colour difference J01 - J03:1997 A05:1996 Dry cleaning Bleaching agencies Wet and dry rubbing Wet and dry rubbing Photochromism Rubbing: organic solvents Aqueous agencies Atmospheric contaminants: oxides of nitrogen BS EN ISO 105:1995 D01 N01 - N04 X12 BS EN ISO 105:X12:2003 BS EN ISO 105:1996 B05 D02 E01, E02, E04 G01 Assessment Manager: BM (Test_022) Page 11 of 50

12 Testing performed by the comprising the laboratories specified in the Appendix COATED FABRICS (cont d) FILLING MATERIALS Colour Fastness Tests and related Opinions and (cont d) Aqueous agencies Weathering: xenon arc Washing and laundering Laundering using non-phosphate reference detergent Biological Tests and related Opinions and BS EN ISO 105:1997 E03, E05 - E08 B04 C06 BS ISO 105:2001 C08 Rag and Flock Cleanliness BS 1425:1960 Fillings and stuffings other than feather and/or down Cleanliness BS 1425:Part 1:1991(1998) Feather and/or down Cleanliness BS 1425:Part 2:1991(1998) MADE-UP TEXTILES Biological Tests and related Opinions and Antibacterial properties Documented In-House Method STS 51 Evaluation of antibacterial finishes on fabrics Examination of antibacterial effect of impregnated textiles by agar diffusion test Examination of antimycotic effect of impregnated textiles by agar diffusion test Fungicides: evaluation on textiles; mildew and rot resistance of textiles Resistance of polyurethane to microbiological deterioration Resistance of textiles to microbiological deterioration AATCC 100:1998 SNV :1976 and 1994 SNV :1976 and 1994 AATCC 30:1998 AATCC 30:1981 Documented In-House Method B/PU/1:1981 BS 6085:1992 Assessment Manager: BM (Test_022) Page 12 of 50

13 Testing performed by the comprising the laboratories specified in the Appendix MADE-UP TEXTILES (cont d) Biological Tests and related Opinions and (cont d) Antibacterial activity assessment of textile materials: parallel streak method Chemical Tests and related Opinions and AATCC 147:1998 Ash content BS 6646:1985(1996) Certain water- or alkali-soluble additives Conductivity, ph, water-soluble matter in aqueous extracts BS 4032:1978(1995) BS 3266:1981(1995) BS 5F 100:1991:Methods 43 to 45 BS 6F 100:1998, Sections 4.2 to 4.4 ph of aqueous extracts BS EN 1413:1998 Degree of cure measurements Documented In-House Method 37 (NAMAS File) Fluidity of cellulose BS 2610:1978(1995) Fluidity of linen BS 3090:1978(1995) Formaldehyde, odour in resin-treated fabric by the sealed jar method BS 6806:Part 3:1987(1993) AATCC BS EN ISO 14184:Part 2:1998 Free formaldehyde (BS Method) BS 6806:Part 2:1987(1993) Free hydrolysed formaldehyde BS EN ISO 14184:Part 1:1998 Free formaldehyde (Japanese Law) Japanese Law Nitrogen content Documented In-House Method 36 (NAMAS File) Oil, fats and waxes in cotton Documented In-House Method (based on BS 3477:1962(1982)) Oil, fats and waxes in wool BS 3582:1981(1995) Phosphorus content Documented In-House Method 38 (NAMAS File) Assessment Manager: BM (Test_022) Page 13 of 50

14 Testing performed by the comprising the laboratories specified in the Appendix MADE-UP TEXTILES (cont d) Chemical Tests and related Opinions and (cont d) Preparation of samples BS 4658:1978(1996) Preservative content (BS Method) BS 2087:Part 2:1981 BS 2087:Part 2:1992 Preservative content (STS Method) A1 Qualitative Analysis of: Binary fibre mixtures Ternary fibre mixtures Quantitative analysis of fibre mixtures STS Method, Appendix 1 of Laboratory Manual ISO 1833:1977 ISO 5088:1976 BS 4407:1988(1995) excluding Method 17 (+ Amd 9436) Total formaldehyde BS 6806:Part 1:1987(1993) Viscosity number of polyamide ISO 307:1994 Wet ashing BS 6648:1986(1994) Determination of soluble hexavalent chromium Colour Fastness Tests and related Opinions and Artificial light: xenon arc Washing and laundering BS 6810:1987(1996) BS EN ISO 105:1999 B02 BS EN 20105:1993/BS 1006:1990 C01 - C05 ISO 105 Colour and colour difference J01 - J03:1997 A05:1996 Dry cleaning Bleaching agencies Wet and dry rubbing BS EN ISO 105:1995 D01 N01 - N04 X12 Assessment Manager: BM (Test_022) Page 14 of 50

15 Testing performed by the comprising the laboratories specified in the Appendix MADE-UP TEXTILES (cont d) Colour Fastness Tests and related Opinions and (cont d) Photochromism Rubbing: organic solvents Aqueous agencies Atmospheric contaminants: oxides of nitrogen Aqueous agencies Weathering: xenon arc Washing and laundering Laundering using non-phosphate reference detergent BS EN ISO 105:1996 B05 D02 E01, E02, E04 G01 BS EN ISO 105:1997 E03, E05 - E08 B04 C06 BS ISO 105:2001 C08 PROTECTIVE CLOTHING Oil rating AATCC 118:1997 BS EN ISO 14419:1999 Surface and interfacial tension of solutions of surface active agent Resistance to penetration by synthetic blood Resistance to blood borne pathogens using Phi-X174 bacteriophage penetration ASTM D (1995) ASTM F ASTM F FLOOR COVERINGS: TEXTILE Chemical Tests and related Opinions and Formaldehyde, odour in resin-treated fabric by the sealed jar method BS 6806:Part 3:1987(1993) AATCC Free formaldehyde (BS Method) BS 6806:Patrt 2:1987(1993) Free formaldehyde (Japanese Law) Japanese Law Preservative content (BS Method) BS 2087:Part 2:Section 8:1992 Total formaldehyde BS 6806:Part 1:1987(1993) Assessment Manager: BM (Test_022) Page 15 of 50

16 Testing performed by the comprising the laboratories specified in the Appendix FLOOR COVERINGS: TEXTILE (cont d) LEATHER PAINT and VARNISHES Colour Fastness Tests and related Opinions and Artificial light: xenon arc Colour and colour difference Shampoo Dry cleaning Bleaching agencies Wet and dry rubbing Wet and dry rubbing Aqueous agencies Rubbing: organic solvents Atmospheric contaminants: oxides of nitrogen Aqueous agencies Weathering xenon arc Colour Fastness Tests and related Opinions and Artificial light: xenon arc Colour and colour difference Dry cleaning Rubbing: organic solvents Weathering: xenon arc Aqueous agencies, water spotting BS EN ISO 105:1999 B02 ISO 105:1997 J01 - J03 UK-TB BS EN ISO 105:1995 D01 N01 - N04 X12 BS EN ISO 105:X12:2003 BS EN ISO 105:1996 E01, E02, E04 D02 G01 BS EN ISO 105:1997 E03, E05 - E08 B04 BS EN ISO 105:1999 B02 BS 1006:1990 J01 BS EN ISO 105:1995 D01 D02 BS EN ISO 105:1997 B04 E07 Colour measurement ISO 7724:Part 2:1984 Calculation of colour differences ISO 7724:Part 3:1984 Assessment Manager: BM (Test_022) Page 16 of 50

17 Testing performed by the comprising the laboratories specified in the Appendix SAFETY COLOURS and SAFETY SIGNS Colour measurement/chromaticity ISO/DIS 3864:1997, Sections 12, , and 12.2 TOYS Toys - Chemical and related Opinions and Specification for migration of certain elements BS EN 71-3:1995 BS 5665:Part 3:1995 JEWELLERY And items in prolonged contact with the skin Nickel Directive and related opinions and Nickel release BS EN 1811:1999 Simulated wear - nickel release BS EN 12472:1999 PACKAGING PLASTICS Semi-crystalline polymer and textiles PROCESS CHEMICALS Temperature and time/temperature indicators Reference testing Determination of melting behaviour capillary tube method Fire Tests and related Opinions and BS 7908:1999 BS EN ISO 3146:1997/ BS 2782:Part 1:Method 125A:1991 Ready biodegradability OECD 301B:1992 OECD 301D:1992 TOYS Filled soft toys CELLULOSIC AND SYNTHETIC FIBRES, YARNS AND FABRICS AND YARNS AND FABRICS MADE FROM BLENDS OF SUCH FIBRES Migration of the elements antimony, arsenic, barium, cadmium, chromium, lead, mercury, selenium Chemical Tests and related Opinions and Determination of water or alkali soluble additives BS 5665:Part 3:1989 EN 71:Part 3:1988 Also BS 5665:Part 3:1995 /BS EN 71:Part 3: Shirley site BS 4032:1978(1986) Assessment Manager: BM (Test_022) Page 17 of 50

18 Testing performed by the comprising the laboratories specified in the Appendix BTTG HIGH PERFORMANCE MATERIALS Trafford Park, Manchester FABRICS Textile Yarns Tensile tests on yarn (load and extension) BS EN ISO 2062:1995 BS 1983:Part 1:1989 (withdrawn) Knot strength and loop strength BS 1932:Part 2:1989(1997) Textile Fabrics: Abrasion (Martindale) Bursting strength BS 5690:1991(1997) (withdrawn) BS EN ISO 12947:Parts 1-4:1999 BS 4768:1972(1997) (withdrawn) ISO 2960:1974 BS EN ISO 13938:Part 1:1999 Calculation of small colour differences BS 6923:1988(1994) Dimensional stability (dry heat) Dimensional stability (immersion in water) Dimensional stability (methods of preparation) Dimensional stability (procedure and repeatability) Dimensional stability (washing) Fabric width BS 1771:Part 2:1984 (withdrawn) BS 4736:1985(1996) ISO 7771:1995 BS 5F 100:1991:Method 22 and BS 6F 100:1998, Section 3.6 BS 4931:1986 (withdrawn) BS EN ISO 3759:1995 BS 5807:1987 (withdrawn) BS 4923:1980 (withdrawn) ISO 6330:2001 ISO 5077:1994 BS EN ISO 6330:2001 BS EN 26330:1994 BS EN 25077:1994 BS 1930:1990 (withdrawn) BS EN 1773:1997 Assessment Manager: BM (Test_022) Page 18 of 50

19 Testing performed by the comprising the laboratories specified in the Appendix FABRICS (cont d) (cont d) Textile Fabrics: (cont d) Mass per unit area BS 2471:1978(1997) BS EN 12127:1998 BS 5F 100:1991:Method 18 BS 6F 100:1998, Section 3.2 Stiffness BS 3356:1990 Tear strength (BS 5F 100) BS 5F 100:1991:Method 21 BS 6F 100:1998, Section 3.5 Tear strength (Elmendorf) ASTM D1424:1983 and ISO 9290 (1990) Tear strength (Trouser Tear) BS EN ISO 13937:Part 2: Tear strength (Tongue Tear) BS Handbook 11:1974 BS EN ISO 13937:Part 4: Tear strength (Wing Rip) BS 4303:1968(1995) BS EN ISO 13937:Part 3: ( + indicates electronic only) Tensile strength and elongation Thickness of fabric BS 2576:1986(1995) (withdrawn) BS 5F 100:1991:Method 19 BS 6F 100:1998, Section 3.3 ISO 5081:1977 ISO 5082:1982 BS EN ISO 13934:Parts 1 and 2:1999 BS 2544:1987 (withdrawn) BS EN ISO 5084:1997 Washing and drying BS 4923:1980 BS 5651:1978 BS 5651:1989(1997) BS EN ISO 6330:2001 BS EN 26330:1994 BS EN 25077:1994 BS EN ISO 10528:1995 BS EN ISO 12138:1997 Assessment Manager: BM (Test_022) Page 19 of 50

20 Testing performed by the comprising the laboratories specified in the Appendix FABRICS (cont d) (cont d) Woven Fabrics Construction BS 2861:1984(1996) Threads per unit length BS 2862:1984(1990) (withdrawn) BS 5F 100:1991:Method 17 BS 6F 100:1998, Section 3.1 BS EN 1049:Part 2:1994 Non-Woven Fabrics Mass/unit area ISO :1989 Thickness ISO :1995 Tensile strength and elongation ISO :1989 Tear resistance ISO :1997 Barrier Properties Air permeability BS 5636:1990 (withdrawn) BS EN ISO 9237:1995 Airborne linting propensity BS 6909:1988(1994) Resistance of fabrics to an artificial shower Resistance to water penetration (hydrostatic head) - textile fabrics BS 5066:1974(1994) ISO 811:1981 BS EN 20811:1992(1996) Thermal resistance or conductivity BS 4745:1990(1995) ISO 5085:Part 1:1989 Spray rating BS EN 24920:1992(1996) ISO 4920:1981 Water repellency (Bundesmann) BS Handbook 11:1974 BS 5F 100:1991:Method 24 BS 6F 100:1998, Section 3.8 Measurement of water vapour permeability index BS 7209:1990(1997):Appendix B Assessment Manager: BM (Test_022) Page 20 of 50

21 Testing performed by the comprising the laboratories specified in the Appendix FABRICS (cont d) (cont d) Barrier Properties (cont d) UV radiation through clothing fabrics BS 7914:1998 AATCC 183:1998 Solar UV protective properties BS EN 13758:Part 1:2002 Sun protection clothing AS/NZ 4399:1996 Coated Fabrics BS 3424 Preparation Part Conditioning Part BS EN ISO 2231:1995 Abrasion (Martindale) Part 24:Method 27A (1996) Modes A and B, 1990/1973 Coating adhesion ISO 2411:2000 BS EN ISO 2411:2000 Adhesion of coating Part 7:Method 9:1982(1996) Blocking test ISO 5978:1990 Part 11:Method 13: 1982/ BS EN 25978:1993 Breaking load and extension Part 4:Method 6:1982(1996) ISO 1421:1977 ISO 1421:1998 Bursting strength Part 6:Method 8:1982(1996) ISO 3303:1990 Crumple flex Part 9:Method 11C:1996 Also ISO 7854:1995 BS EN ISO 7854:1997 Flexing resistance (Schild Knecht) Surface drag ISO 7854:Method B:1984 (withdrawn) Part 10:Method 12B:1987(1996) Assessment Manager: BM (Test_022) Page 21 of 50

22 Testing performed by the comprising the laboratories specified in the Appendix COATED FABRICS (cont d) (cont d) Coated Fabrics (cont d) BS 3424 (cont d) Tear strength Part 5:Method 7:1982(1996) ISO 4674:1977 ISO 4674:Part 2:1998 Tear strength (Trouser Tear) BS EN ISO 13937:Part 2:2000 (electronic only) Tropical ageing test Part 12:Method C:1996 ISO 1419:1995 Thickness ISO 4648:1991 ISO 2286:Part 3:1998 BS EN 22286:1994 (withdrawn) BS 3424:Part 1:1994 Federal Test Method Standard 191 Section Width: mass and length BS EN 22286:1994 (withdrawn) Width ISO 2286:Part 1:1998 Total mass/coating mass/substrate mass ISO 2286:Part 2:1998 Barrier Properties Air permeability Resistance of fabrics to an artificial shower Resistance to water penetration (hydrostatic head) - coated fabrics BS 5636:1990 (withdrawn) BS EN ISO 9237:1995 BS 5066:1974(1993) BS 3424:Part 26:Methods 29A and 29C:1986 Thermal resistance or conductivity BS 4745:1990(1995) ISO 5085:Part 1:1989 Spray rating BS EN 24920:1992(1996) ISO 4920:1981 Assessment Manager: BM (Test_022) Page 22 of 50

23 Testing performed by the comprising the laboratories specified in the Appendix MADE-UP TEXTILES (cont d) Barrier Properties (cont d) Water repellency (Bundesmann) BS Handbook 11:1974 BS 5F 100:1991:Method 24 BS 6F 100:1998, Section 3.8 Measurement of water vapour permeability index BS 7209:1990(1997):Appendix B BS 3424:Part 34:Method 37:1992 BS 3546:Part 4:1991:Appendix C Abrasion (Martindale) BS 5690:1991(1997) BS EN ISO 12947:Parts 1-4:1999 Bursting strength BS 4768:1972(1997) (withdrawn) BS EN ISO 13938:Part 1:1999 Calculation of small colour differences BS 6923:1988(1994) Dimensional stability (dry heat) Dimensional stability (immersion in water) Dimensional stability (methods of preparation) Dimensional stability (procedure and repeatability) Dimensional stability (washing) BS 1771:Part 2:1984 (withdrawn) BS 4736:1985(1996) BS 5F 100:1991:Method 22 and BS 6F 100:1998, Section 3.6 BS 4931:1986 (withdrawn)/ BS EN ISO 3759:1995 BS 5807:1987 (withdrawn) BS 4923:1980 (withdrawn) ISO 6330:1984 ISO 5077:1994 BS EN ISO 6330:2001 BS EN 26330:1994 BS EN 25077:1994 Mass per unit area BS 2471:1978(1997) BS 5F 100:1991:Method 18 BS 6F 100:1998, Section 3.2 Stiffness BS 3356:1990 Tear strength BS 5F 100:1991:Method 21 BS 6F 100:1998, Section 3.5 Assessment Manager: BM (Test_022) Page 23 of 50

24 Testing performed by the comprising the laboratories specified in the Appendix MADE-UP TEXTILES (cont d) (cont d) Tear strength (Elmendorf) ASTM D1424:1996 ISO 9290 (1990) Tear strength (Trouser Tear) BS EN ISO 13937:Part 2: Tear strength (Tongue Tear) BS Handbook 11:1974 BS EN ISO 13937:Part 4: Tear strength (Wing Rip) BS 4303:1968(1995) BS EN ISO 13937:Part 4: Tensile strength and elongation Thickness of fabric BS 2576:1986(1995) (withdrawn) BS 5F 100:1991:Method 19 BS 6F 100:1998, Section 3.3 ISO 5081:1977 ISO 5082:1982 BS EN ISO 13935:Parts 1 and 2:1999 BS 2544:1987 (withdrawn) BS EN ISO 5084:1997 ( + indicates electronic only) Woven Fabrics Construction BS 2861:1984(1996) Threads per unit length in woven fabric BS 2862:1984(1990) (withdrawn) BS 5F 100:1991:Method 17 BS 6F 100:1998, Section 3.1 BS EN 1049:Part 2:1994 Barrier Properties Air permeability Resistance of fabrics to an artificial shower Resistance to water penetration (hydrostatic head) - textile fabrics BS 5636:1990 (withdrawn) BS 5066:1974(1993) BS EN 20811:1992(1996) ISO 811:1981 Spray rating BS EN 24920:1992(1996) ISO 4920:1981 Assessment Manager: BM (Test_022) Page 24 of 50

25 Testing performed by the comprising the laboratories specified in the Appendix MADE-UP TEXTILES (cont d) Barrier Properties (cont d) Water repellency (Bundesmann) BS Handbook 11:1974 BS 5F 100:1991:Method 24 BS 6F 100:1998, Section 3.8 Measurement of water vapour permeability index BS 7209:1990(1997):Appendix B BS 3424:Part 34:Method 37 BS 3546:Part 4:1991:Appendix C Sun protection clothing AS/NZS 4399:1996 Children s Clothing - Requirements for protection against UV radiation BS 7949:1999 PROTECTIVE CLOTHING Abrasion resistance BS EN 530:1995 Requirements for protective clothing against foul weather pren 343:1996 and 1993 (Tests only) High Visibility Warning Clothing Design/background area Shirley Method 134:1998 Chromaticity background material EN 471:1994(2003) BS EN 1150:1999 Railway Standard, GO/RT 3279:2000 Barrier Properties Puncture resistance BS EN 863:1996 Thickness ISO 4648:1991 ISO 2286:1986/ BS EN 22286:1994/ BS 3424:Part 1:1994 Federal Test Method Standard 191 Section GLOVES General Requirements for Gloves EN 420:1994(2003) Protective gloves against liquid chemicals and micro-organisms BS EN 374:Parts 1-3:1994(1997) Assessment Manager: BM (Test_022) Page 25 of 50

26 Testing performed by the comprising the laboratories specified in the Appendix GLOVES (cont d) Mechanical Risk Puncture resistance BS EN 388:1994 EN 388:1994 DIN 4841:Part 1:1981 Thickness ISO 4648:1991 ISO 2286:1986/ BS 3424:Part 1:1994 Standard 191 Section GEOTEXTILES AND GEOTEXTILE RELATED PRODUCTS Geotextiles Breaking load and extension (grab method) ASTM D4632:1991 Water-flow, normal to the plane BS EN ISO 11058:1999 In-plane water flow capacity BS 6906:Part 7:1990(1995) (withdrawn) BS EN ISO 12958:1999 Mass per unit area ISO 9864:1990 BS EN 965:1995 ASTM D5261:1992 Puncture resistance (CBR puncture test) Resistance to perforation (cone drop test) BS 6906:Part 4:1989 (withdrawn) DIN 54307:1982 BS EN ISO 12236:1996 ASTM D6241:1999 BS 6906:Part 6:1990 (withdrawn) BS EN 918:1996 Index puncture resistance ASTM D4833:1988 Short term compression ASTM D1621:1994 Sampling and preparation of test specimens Tensile properties using a wide width strip ISO 9862:1990/ BS EN 963:1995 ASTM D4595:1986(1994) BS 6906:Part 1:1987(1995) Assessment Manager: BM (Test_022) Page 26 of 50

27 Testing performed by the comprising the laboratories specified in the Appendix GEOTEXTILES AND GEOTEXTILE RELATED PRODUCTS (cont d) (cont d) Geotextiles (cont d) Wide-width tensile test ISO 10319:1993/ BS EN ISO 10319:1996 Tensile test for joints/seams by wide-width method Peel strength (geocomposites) ISO 10321:1992/ BS EN ISO 10321:1996 ASTM D4632:1991(mod) Thickness at specified pressures ISO 9863:Part 2:1996 ISO 9863:1990 (withdrawn) BS EN 964-1:1995 ASTM D5199:2001 Trapezoid tear strength ASTM D4533:1991(1996) Abrasion damage simulation BS EN ISO 13427:1998 Water flow normal to the plane of a geotextile under a constant head Pore/Opening size by dry sieving by wet sieving BS 6906:Part 3:1989(1995) (withdrawn) BS 6906:Part 2:1989(1995) (withdrawn) BS EN ISO 12956:1999 GEOMEMBRANES Tensile properties of plastics ANSIN/NSF Modification Standard 54: Annex A, Part 8, using Type 4 Die based on ASTM D638:1996 Tensile properties ASTM D6693:2003 EN ISO 527-1:1996 EN ISO 527-3:1995(1998) Initial tear resistance of plastic film and sheeting Density of plastics ASTM D1004:1994a ASTM D1505:1998 el Assessment Manager: BM (Test_022) Page 27 of 50

28 Testing performed by the comprising the laboratories specified in the Appendix GEOMEMBRANES (cont d) (cont d) Thickness of Geomembranes ANSI/NSF Modification Standard 54: 1993, Annex A, Part 1, based on ASTM D751:1995 ASTM D5199:2001 ASTM D1593:1999 Thickness BS EN 964-1:1995 Carbon black content ASTM D1603:1994 Carbon black dispersion ASTM D5596:1994 Puncture resistance Federal Test Method Standard 101C, Method 2065:1980 Puncture resistance (CBR puncture test) BS 6906:Part 4:1989 (withdrawn) BS EN ISO 12236:1996 DIN 54307:1982 ASTM D6241:1999 Index puncture resistance ASTM D4833:1988 Peel and shear strength of bonded seams Stress cracking using notched constant tensile load ANSI/NSF Modification Standard 54: 1993, Appendix A, Part 3 and Part 5, based on ASTM D413:1982(1993) and ASTM D4437:1984(1988) ASTM D6392:1999 ASTM D5397:1999 Dimensional stability ASTM D1204:2002 Water absorption ASTM D570:1995 Methodology for cylinder testing of protectors for geomembranes Environment Agency - March 1998 BENTONITE CLAY Confined swell GRI Test Method GCL-1 Free swell STS Method 130:1995 Assessment Manager: BM (Test_022) Page 28 of 50

29 Testing performed by the comprising the laboratories specified in the Appendix BENTONITE CLAY (cont d) (cont d) Swell Index of Clay ASTM D5890:1995 Montmorillonite content (Methylene blue capacity) STS Method 131:1995 Water absorption of bentonite ASTM E946:1992 GEOSYNTHETIC CLAY LINERS Mass per unit area (GCL) ISO 9864:1990 ASTM D5993:1996 BS EN 965:1995 ASTM D5261:1992 Puncture resistance (CBR puncture test) Breaking load and extension (grab method) BS 6906:Part 4:1989 (withdrawn) BS EN ISO 12236:1996 DIN 54307:1982 ASTM D6241:1999 ASTM D4632:1991 Moisture content (GCL) ASTM D2216:1992 Tensile properties using a wide width strip ASTM D4595:1986(1994) BS EN ISO 10319:1996 BS 6906:Part 1:1987(1995) (withdrawn) ISO 10319:1993 Thickness at specified pressures ISO 9863:Part 2:1996 ISO 9863:1990 (withdrawn) BS EN 964-1:1995 ASTM D5199:2001 Peel strength ASTM D4632:1991(mod) ASTM D413:1982(1993) Index puncture resistance ASTM D4833:1988 Index flux ASTM D Hydraulic conductivity ASTM D (GR1 GCL2) Assessment Manager: BM (Test_022) Page 29 of 50

30 Testing performed by the comprising the laboratories specified in the Appendix FLEXIBLE SHEETS FOR WATER PROOFING Determination of tensile properties BS EN 12311:Part 1:2000 Thickness BS EN :2001 Mass per unit area BS EN :2001 Watertightness EN 1928:2000, Method A EN 1928:2000, Method A modified by pren and EN Resistance to water penetration BS EN 13111:2001 Tensile properties BS EN :2000 BS EN :2000 modified by pren and EN Dimensional stability BS EN :2001 Tear resistance (nail shank) BS EN :2000 BS EN :2000 modified by pren and EN Artificial ageing (elevated temperature) BS EN 1296:2001 BS EN 1296:2001 modified by pren and EN Water vapour transmission BS EN 1931:2000 BS EN ISO 12572:2001 BS 3177:1959 LEATHER Barrier Properties Measurement of water vapour permeability index BS 7209:1990(1997), Appendix B Continued on Page 31 Assessment Manager: BM (Test_022) Page 30 of 50

31 Testing performed by the comprising the laboratories specified in the Appendix FIRE TECHNOLOGY SERVICES Altrincham Fire Testing and related Opinions and FABRICS and FILLINGS Ignitability BS 5852:Part 1:1979 BS 5852:Part 2:1982 BS 5852:1990(1998) BS EN :1994 BS EN :1994 ISO :1987 ISO :1988 FABRICS: Flammability and related Opinions and BS 5438:1976 BS 5438:1989 BS EN 532:1995 BS EN ISO 6940:1995 BS EN ISO 6941:1995 used in sleepwear and dressing gowns BS 5722:1984 BS 5722:1991 for curtains and drapes BS 5867:Part 2:1980(1993) for protection against heat and flame BS EN 1101:1996 BS EN 1102:1996 BS 6249:Part 1:1982 (withdrawn) BS EN 533:1997 BS ISO 15025:2000 BS EN ISO 15025:2002 for bedding BS 7175:1989(1994) BS 5866:Part 4:1991 BS EN ISO 12952:Parts 1-4:1999 Fabrics for Apparel BS EN 1103:1996 UPHOLSTERED FURNITURE Resistance to ignition and related Opinions and BS 7176:1995 Assessment Manager: BM (Test_022) Page 31 of 50

32 Testing performed by the comprising the laboratories specified in the Appendix MATTRESSES, DIVANS and BED BASES Ignitability and related Opinions and BS 6807:1986:Sections 1, 2 and 4 BS 6807:1996:Sections 1, 2 and 4 BS EN 597-1:1995 BS EN 597-2:1995 Resistance to ignition BS 7177:1996 TENTS Ignitability and related Opinions and BS 7157:1989(1994) TEXTILES USED in the CONSTRUCTION of MARQUEES and SIMILAR TEXTILE STRUCTURES Flammability and related Opinions and BS 7837:1996 PROTECTIVE CLOTHING and GLOVES Burning behaviour EN 407:1994, Clause 6.3 EN 407:2004, Clause 6.3 Heat transfer (radiation) BS EN 366:1993 ISO 6942:1993 BS EN ISO 6942:2002 Heat transfer (flame) BS EN 367:1992 ISO 9151:1995 Heat transfer (contact heat) BS EN 702:1995 ISO 12127:1996 Molten metal splash BS EN 373:1993 ISO 9185:1990 Small splashes of molten metal BS EN 348:1992 ISO 9150:1988 Heat resistance BS EN 469:1995, Annex A BS EN 659:1996, Annex A Protection against heat BS ISO 17493:2000 Protection against liquid chemicals EN 368:1993 ISO 6530:1990 Mechanical Risk Test (for automobile drivers) FIA Standard No 8856:2000 Appendix II Assessment Manager: BM (Test_022) Page 32 of 50

33 Testing performed by the comprising the laboratories specified in the Appendix TEXTILES Dimensional change ISO 5077:1994 ISO 5077:1984 ISO 3759:1984 Washing BS 5651:1989 BS EN ISO 10528:1995 BS EN 26330:1994 ISO 6330:1984 BS EN ISO 6330:2001 Water soak prior to flammability testing BS 5651:1978 Clause 4 BS 5651:1989 Clause 3 Oven gloves BS 6526:1998 Continued on Page 34 Assessment Manager: BM (Test_022) Page 33 of 50

34 Testing performed by the comprising the laboratories specified in the Appendix SHIRLEY TECHNOLOGIES LTD Leeds FIBRES Strength BS EN ISO 5079:1996 Length IWTO TM-5-97 (Draft) IWTO (E) IWTO (E) ISO 6989:1981 Diameter IWTO 6-92 IWTO 8-89 (E) IWS TM 24:1996 BS 2043:1968(1997) Chemical Tests and related Opinions and Determination of ph BS 3266:1981(1995), Section 8.3 (withdrawn) BS EN 1413:1998 Alkali solubility BS 3568:1988(1996) Urea bisulphite solubility BS 3584:1989(1994) Solvent extraction BS 3582:1981(1995) Quantitative fibre composition BS 4407:1988(1995) excluding Method 17 Colour Fastness Tests and related Opinions and Artificial light: xenon arc Weathering: xenon arc Washing Dry cleaning BS EN ISO 105:1999 B02 B04 BS 1006:1990/BS EN 20105:1993 C01 - C05 BS EN ISO 105:1995 D01 Assessment Manager: BM (Test_022) Page 34 of 50

35 Testing performed by the comprising the laboratories specified in the Appendix FIBRES (cont d) YARNS Colour Fastness Tests and related Opinions and (cont d) Rubbing: Organic solvents Water Sea water Chlorinated water Perspiration Photochromism Spotting: Water Domestic and commercial laundering Laundering using non-phosphate reference detergent Alkaline milling Burnt gas fumes Bleaching: Hypochlorite Bleaching: Peroxide Bleaching: Sodium chlorite: Mild Bleaching: Sodium chlorite: Severe dry Heat Wet and dry rubbing Perborate BS EN ISO 105:1996 D02 E01 E02 E03 E04 BS EN ISO 105:1996 B05 BS EN ISO 105:1997 E07 BS EN ISO 105:1997 C06 BS ISO 105:2001 C08 BS 1006:1990 E12 G02 BS 1006:1990/BS EN ISO 105:1995 N01 N02 N03 N04 P01 BS 1006:1990/BS EN ISO 105:1995 BS EN ISO 105:X12:2003 M&S C10:1985 Strength - Tensile tests BS EN ISO 2062:1995 Count - Linear density BS EN ISO 2060:1995 Twist of yarn from package BS EN ISO 2061:1996 Levelness, twist-untwist (re-twist method) ASTM D1422:1992 Assessment Manager: BM (Test_022) Page 35 of 50

36 Testing performed by the comprising the laboratories specified in the Appendix YARNS (cont d) (cont d) Levelness IWTO (Draft) Correct invoice mass (weight) BS 4784:Parts 1 and 2:1988(1995) BS 4784:Part 3:1988(1994) Chemical Tests and related Opinions and Determination of ph BS 3266:1981(1998), Section 8.3 (withdrawn) BS EN 1413:1998 Alkali solubility BS 3568:1988(1996) Urea bisulphite solubility BS 3584:1989(1994) Colour Fastness Tests and related Opinions and Artificial light: xenon arc Weathering Photochromism Washing Domestic and commercial laundering Laundering using non-phosphate reference detergent Dry cleaning Rubbing: Organic solvents Water Sea water Chlorinated water Perspiration BS EN ISO 105:1999 B02 B04 BS 1006:1990/BS EN ISO 105:1996 B05 BS 1006:1990/BS 20105:1993 C01 - C05 BS 1006:1990/BS EN ISO 105:1996 C06 BS ISO 105:2001 C08 BS 1006:1990/BS EN ISO 105:1996 D01 BS 1006:1990/BS EN ISO 105:1996 D02 E01 E02 E03 E04 Assessment Manager: BM (Test_022) Page 36 of 50

37 Testing performed by the comprising the laboratories specified in the Appendix YARNS (cont d) Colour Fastness Tests and related Opinions and (cont d) Spotting: Water Alkaline milling Burnt gas fumes Bleaching: Hypochlorite Bleaching: Peroxide Bleaching: Sodium chlorite: Mild Bleaching: Sodium chlorite: Severe Dry heat Wet and dry rubbing BS 1006:1990/BS EN ISO 105:1997 E07 BS 1006:1990/ E12 G02 BS 1006:1990/BS EN ISO 105:1995 N01 N02 N03 N04 P01 BS 1006:1990/BS EN ISO 105:1995 BS EN ISO 105:X12:2003 Perborate M&S C10:1985 FABRICS Width Mass per unit area BS 1930:1990 (withdrawn) BS EN 1773:1993 BS 2471:1978(1997) (withdrawn) BS EN 12127:1998 BS 6F 100:1998, Section 3.2 Shorn pile weight IWS TM 15:1996 Thickness Tensile strength and elongation Peel strength BS 2544:1987 (withdrawn) BS EN ISO 5084:1997 BS 2576:1986(1995) (withdrawn) IWS TM 4:1996 ISO 5081:1977 BS EN ISO 13934:Part 1:1999 BS 6F 100:1998, Section 3.3 UK/SC/4627B.1987, Annex B Grab strength ISO 5082:1982 BS EN ISO 13934:Part 2:1999 Assessment Manager: BM (Test_022) Page 37 of 50

38 Testing performed by the comprising the laboratories specified in the Appendix FABRICS (cont d) (cont d) Spray rating BS EN 24920:1992(1996) Shower test BS 5066:1974(1993) Woven Fabrics Threads per unit length BS EN 1049/2(1994) BS 6F 100:1998, Section 3.1 Yarn crimp ISO 7211/3 Yarn twist ISO 7211/4 Yarn count/linear density ISO 7211/5 Seam tensile properties: Strip method Grab method BS EN 13935:Part 1:1999 BS EN 13935:Part 2:1999 Seam slippage BS 3320:1988(1995) BS EN ISO :2004 IWS TM 117:1980 BS 2543:Annex A:1995 BS EN ISO :2004 Stiffness BS 3356:1990 Tear strength (Wing Rip) BS 4303:1968(1995) BS EN ISO 13937:Part 3:2000 (electronic) Tear strength (Tongue Tear) BS 6F 100:1998, Section BS EN ISO 13937:Part 4:2000 (electronic) Tear strength (Trouser Tear) IWS TM 172:1996 BS EN ISO 13937:Part 2:2000 (electronic) Dimensional stability: Washing BS 1955:1981(1991) (withdrawn) BS EN 26330:1994 ISO 6330:1984 BS EN 25077:1994 Assessment Manager: BM (Test_022) Page 38 of 50

39 Testing performed by the comprising the laboratories specified in the Appendix FABRICS (cont d) (cont d) Dimensional stability: (cont d) Cold water immersion BS 4736:1985(1996) ISO 7771:1985 BS 6F 100:1998, Section 3.6 Method of preparation BS EN ISO 3759:1995 BS 4931:1986 (withdrawn) Free stream BS 4323:1979(1995) ISO 3005:1978 IWTO 29/76 Wool mark IWS TM 31:1996 Hot air UK/SC/4952, Annex A Washing before flammability testing ISO 10528:1995 Bursting strength BS 4768:1972(1997) (withdrawn) IWS TM 29:1983 BS EN ISO 13938:Part 1:1999 Drape BS 5058:1973(1997) Constructional Properties of Knitted Fabrics: BS 5441:Sections 2 and 3:1988(1994) Cover factor of knitted fabrics IWS TM 169:1980 Air permeability Abrasion resistance BS 5636:1990 (withdrawn) BS 5690:1991(1997) (withdrawn) IWS TM 112:1987 BS EN ISO 12947:Parts 1, 2 and 4: 1999 BS EN 14465:Annex A:2003 Crease recovery BS EN 22313:1992 Pilling BS 5811:1986(1997) IWS TM 152:1980 IWS TM 196:1980 BS EN ISO 12945:Part 1:2001 Assessment Manager: BM (Test_022) Page 39 of 50

40 Testing performed by the comprising the laboratories specified in the Appendix FABRICS (cont d) (cont d) Underarm seam strength IWS TM 195:1980 Performance on tumble drying specifications for upholstery fabrics IWS TM 254:1987 BS 2543:1995 (excludes soiling) Chemical Tests and related Opinions and Determination of ph BS 3266:1981(1989), Section 8.3 (withdrawn) BS EN 1413:1998 Alkali solubility BS 3568:1988(1996) Urea bisulphate solubility BS 3584:1989(1994) Solvent extraction BS 3582:1981(1995) Quantitative fibre composition BS 4407:1988 excluding Method 17 Colour Fastness Tests and related Opinions and Artificial light: xenon arc Weathering: xenon arc Photochromism Washing Domestic and commercial laundering Laundering using non-phosphate reference detergent Dry cleaning BS EN ISO 105:1999 B02 B04 BS 1006:1990/BS EN ISO 105:1996 B05 BS 1006:1990/BS EN 20105:1993 C01 - C05 BS 1006:1990/BS EN 20105:1993 B06 BS ISO 105:2001 C08 BS 1006:1990/BS EN ISO 105:1996 D01 Assessment Manager: BM (Test_022) Page 40 of 50

41 Testing performed by the comprising the laboratories specified in the Appendix FABRICS (cont d) Colour Fastness Tests and related Opinions and (cont d) Rubbing: Organic solvents Water Sea water Chlorinated water Perspiration Spotting: Water Alkaline milling Burnt gas fumes Bleaching: Hypochlorite Bleaching: Peroxide Bleaching: Sodium Chlorite: Mild Bleaching: Sodium Chlorite: Severe Dry Heat Wet and dry rubbing Acid chlorination of wool: Sodium dichlordisocyanurate BS 1006:1990/BS EN ISO 105:1996 D02 E01 E02 E03 E04 BS 1006:1990/BS EN ISO 105:1997 E07 BS 1006:1990/ E12 G02 BS 1006:1990/BS EN ISO 105:1995 N01 N02 N03 N04 P01 BS 1006:1990/BS EN ISO 105:1995 BS EN ISO 105:X12:2003 BS EN ISO 105:1997 X14 Continued on Page 42 Assessment Manager: BM (Test_022) Page 41 of 50

42 Testing performed by the comprising the laboratories specified in the Appendix ADVANCED MATERIALS SERVICES LTD Leeds FABRICS Fire Tests and related Opinions and Ignitability, flame spread BS 5438:1976 (Amd 1981) BS 5438:1989 (Amd 1990/1994)(1997) BS EN 1101:1996 BS EN ISO 6940:1995 BS EN ISO 6941:1995 BS EN 1102:1996 BS EN 1103:1996 IMO Resolution A471 (XII) 1981(1998) Burning behaviour aircraft components CAA spec 8:1974 FAR/JAR 25 App F Part I (4) (16):1993(1998) Part II 1986(1998) Sleepwear and dressing gowns BS 5722:1984 BS 5722:1991 Curtains and Drapes BS 5867:Part 2:1980(1993) Protection against heat and flames BS 6249:Part 1:1982 (withdrawn) BS EN 532:1995 BS EN 533:1997 FABRICS and MADE-UP TEXTILES Electrostatic Tests and related Opinions and Surface resistivity EN 1149:Part 1:1996 BS 6524:1984(1995) Determination of electrical resistance EN 1149:Part 2:1997 BS 2050:1978(2003) Clause A4.1 and A4.2 Charge decay BS IEC :2001 BS EN 1149:Part 3:2004 Assessment Manager: BM (Test_022) Page 42 of 50

43 Testing performed by the comprising the laboratories specified in the Appendix PROTECTIVE CLOTHING Electrostatic properties Surface resistivity Electrical resistance through material BS EN 1149:Part 1:1996 BS EN 1149:Part 2:1997 Charge decay BS EN 1149:Part 3:2004 Electrostatic Tests and related Opinions and Electrical resistance BS ISO 10965:1998 Static electrical propensity (walking test) BS ISO 6356:2000 TEXTILE FLOOR COVERINGS, UNDERLAYS AND BACKINGS Sample preparation BS ISO 1957:2000 Thickness BS 4051:1987(1996) ISO 1765:1986 Effective thickness of backing construction BS 4223:1989(1996) ISO 1766:1986(1999) ISO 1763:1986 ISO 8543:1986 ISO 2549:1986 Apparent (bulk) density (foam backing) BS EN ISO 845:1988 Static loading BS 4939:1987(1996) ISO 3416:1986 Dynamic loading BS 4052:1987(1996) (withdrawn) BS ISO 2094:1999 Thickness, compression and recovery BS 4098:1975(1996) Tuft withdrawal BS 5229:1975(1996) Pilling (Martindale) Fibre shedding Documented In-House Method (E2-20) Documented In-House Method (E2-15) Lisson tretrad BS EN 1963:1998 Assessment Manager: BM (Test_022) Page 43 of 50

44 Testing performed by the comprising the laboratories specified in the Appendix TEXTILE FLOOR COVERINGS, UNDERLAYS AND BACKINGS (cont d) Appearance Retention: Tumbler test - Hexapod - Vetterman BS 6659:Part 2:1986(1996) ISO 10361:2000 BS EN ISO 11378:Part 2:2001 ISO 10361:2000 Castor chair BS EN 985:2001 Edge frying (Vetterman) Assessment BS EN 1814:1998 BS EN 1471:1997 ISO/FDIS 9405:2a BS 6659:Part 1:1986 (withdrawn) IWS TM 247:1992 Size and squareness of carpet tiles BS 5921:1980(1996) Side length, squareness and straightness of tiles BS EN 994:1996 Dimensional Stability: RH changes BS 4682:Part 2:1988(1996) Heat BS 4682:Part 3:1981(1996) Water BS 4682:Part 4:1981(1996) Mechanical action Documented In-House Method based on BS 4682:Part 1:1971 (withdrawn) Heat and/or water BS ISO/PAS 17984:2001 Heat/Water (Aachen) Heat/Water (Carpet Tiles) ISO 2551:1981 (E) BS EN 986:1995 (except distortion) Heat (resilient Floor Coverings) BS EN 434:1994 Tensile strength Delamination BS 2576:1986 (withdrawn) BS EN ISO :1999 BS 7399:1991(1996) (withdrawn) BS ISO 11857:1999 Assessment Manager: BM (Test_022) Page 44 of 50

45 Testing performed by the comprising the laboratories specified in the Appendix TEXTILE FLOOR COVERINGS, UNDERLAYS AND BACKINGS (cont d) (cont d) Classification of needled floor coverings Performance classification BS EN 1470:1998 BS 7131:Part 1:1989 (withdrawn) Classification of pile carpets BS EN 1307:1997 Performance tests (underlays) BS 5808:1991(1996), All parts Electrostatic Tests and related Opinions and Electrical resistance BS 6654:1985(1996) IBM Electrostatic Tests:1974 ICL Electrostatic Tests:1980 BS ISO 10965:1998 Body voltage BS-DD68:1980(1996) ISO 6356:2000 BS EN 1815:1998 Chemical Tests and related Opinions and Solvent extraction BS 3582:1981(1990) Quantitative fibre composition BS 4407:1988, excluding Method 17 Colour Fastness Tests and related Opinions and Light: xenon arc Wet and dry rubbing Shampooing Salt Water Sea water Organic solvents BS EN ISO 105:B02:1999 BS EN ISO 105:X12:1999 BS 1006:UK-TB:1990 BS 1006:UK-TI:1990 BS 1006:UK-TJ:1990 BS EN ISO 105:1996:E02 BS EN ISO 105:1996:D02 Assessment Manager: BM (Test_022) Page 45 of 50

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 118 Lupton Avenue Leeds LS9 6ED Contact: Mr Scott Wiseman Tel: +44 (0)113 248 8830 Fax: +44 (0)113 248 0239 E-Mail: scott@hstts.co.uk Website:

More information

List of tests (2018)

List of tests (2018) SRI Center for Physical Sciences and Technology Textile Institute Department of Textiles Physical-Chemical testing List of tests (2018) 1. Fibre content analysis 1.1 Melting point determination ISO/TR

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Cambridge Road Whetstone Leicester LE8 6LH Contact: Ms Michelle Harrison Tel: +44 (0)116 284 6780 Fax: +44 (0)116 284 6781 E-Mail: michelle.harrison@sgs.com Website: www.sgsleicester.com Testing performed

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK The Warehouse Brewery Lane Leigh Lancashire WN7 2RJ Contact: Mr A J White Tel: +44 (0)1942 265700 Fax: +44 (0)1942 670788 E-Mail: andrew.white@intertek.com

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 31 Kingsland Grange Woolston Warrington Cheshire WA1 4RW Contact: Miss K L Marrow Tel: +44 (0)1925 854360 Fax: +44 (0)1925 851654 E-Mail:

More information

Textile quality management. Mr Dale Carroll CSIRO, Textile and Fibre Technology

Textile quality management. Mr Dale Carroll CSIRO, Textile and Fibre Technology Textile quality management Mr Dale Carroll CSIRO, Textile and Fibre Technology Textile testing Why do you need to test? What does testing involve? Sampling. Selecting the correct test. Selecting the most

More information

SCOPE OF ACCREDITATION. High-visibility clothing EC type examination LST EN ISO 20471:2013. EC type examination LST EN ISO 11611:2008

SCOPE OF ACCREDITATION. High-visibility clothing EC type examination LST EN ISO 20471:2013. EC type examination LST EN ISO 11611:2008 Annex 2 to the Accreditation Certificate No. LA.01.048 issued on 02-07-2013, Page 1 of 2 DEPARTMENT of TEXTILES PHYSICAL-CHEMICAL TESTING Notified body No.1401 of Textile Institute of State scientific

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Units 41 & 43 The Listerhills Park of Science and Commerce Campus Road Bradford BD7 1HR Contact: Ms J Pinkess Tel: +44 (0)1274 303080 Fax:

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SGS GOVMARK TESTING SERVICES, INC. 96 Allen Boulevard, Suite D Farmingdale, NY 11735 Doug Lipp Phone: 631 293 8944 THERMAL Valid To: May 31, 2018 Certificate

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK ccredited to Schedule of ccreditation United Kingdom ccreditation Service 2 Pine Trees, hertsey Lane, Staines-upon-Thames, TW18 3HR, UK Wira House West Park Ring Road Leeds West Yorkshire LS16 6QL Shirley

More information

TESTS LIST 2014 YARNS WOVEN NON WOVEN-PADDED WOVEN GARMENTS AND ACCESSORIES COMFORT TESTS CHEMICAL /ECO-TOXICOLOGICAL TESTS LEATHER TESTS

TESTS LIST 2014 YARNS WOVEN NON WOVEN-PADDED WOVEN GARMENTS AND ACCESSORIES COMFORT TESTS CHEMICAL /ECO-TOXICOLOGICAL TESTS LEATHER TESTS TESTS LIST 2014 YARNS WOVEN NON WOVEN-PADDED WOVEN GARMENTS AND ACCESSORIES COMFORT TESTS CHEMICAL /ECO-TOXICOLOGICAL TESTS LEATHER TESTS ADVICE ON MARKET REGULATIONS STUDIES ON DEFECTIVENESS TECHNICAL

More information

Liner Construction & Testing Guidance Overview

Liner Construction & Testing Guidance Overview Liner Construction & Testing Guidance Overview Ruben Meza, Jr., P.E. Waste Permits Division Municipal Solid Waste Permits Section 2017: TCEQ Environmental Trade Fair Agenda Summary of Revised Guidance

More information

Accreditation No: LAB 043. Pakistan Textile Testing Foundation (PTTF), Faisalabad, Pakistan

Accreditation No: LAB 043. Pakistan Textile Testing Foundation (PTTF), Faisalabad, Pakistan Accreditation No: Awarded to Pakistan Textile Testing Foundation (PTTF), Faisalabad, Pakistan The scope of accreditation is in accordance with the standard specifications outlined in the following page(s)

More information

GB/T Translated English of Chinese Standard: GB/T NATIONAL STANDARD OF THE

GB/T Translated English of Chinese Standard: GB/T NATIONAL STANDARD OF THE Translated English of Chinese Standard: GB/T8685-2008 www.chinesestandard.net Sales@ChineseStandard.net GB NATIONAL STANDARD OF THE PEOPLE S REPUBLIC OF CHINA ICS 59.080.01 W 04 GB/T 8685-2008 Replacing

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Maxwell Road Stevenage Hertfordshire SG1 2EW Contact: Darren Hone Tel: +44 (0)1438 777700 Fax: +44 (0)1438 777800 E-Mail: info@fira.co.uk

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service High Street, Feltham, Middlesex, TW13 4UN, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service High Street, Feltham, Middlesex, TW13 4UN, UK Schedule of ccreditation United Kingdom ccreditation Service 21-47 High Street, Feltham, Middlesex, TW13 4UN, UK ccredited to Unit 14 Wheel Forge Way shburton Road West Trafford Park Manchester M17 1H

More information

Section Specification for Geotextile Used in Permanent Erosion Control Application

Section Specification for Geotextile Used in Permanent Erosion Control Application Project Name: Project Number: 1 GENERAL Section 02370 Specification for Geotextile Used in Permanent Erosion Control Application 1.1 SECTION INCLUDES A. Geotextile to prevent soil loss resulting in excessive

More information

MATERIAL SPECIFICATION FOR GEOTEXTILES

MATERIAL SPECIFICATION FOR GEOTEXTILES ONTARIO PROVINCIAL STANDARD SPECIFICATION OPSS 1860 APRIL 2018 (Formerly OPSS 1860, April 2012) Note: The MUNI implemented in April 2018 replaces OPSS 1860 COMMON, April 2012 with no technical content

More information

MATERIAL SPECIFICATION FOR GEOTEXTILES

MATERIAL SPECIFICATION FOR GEOTEXTILES ONTARIO PROVINCIAL STANDARD SPECIFICATION METRIC OPSS 1860 NOVEMBER 2004 MATERIAL SPECIFICATION FOR GEOTEXTILES TABLE OF CONTENTS 1860.01 SCOPE 1860.02 REFERENCES 1860.03 DEFINITIONS 1860.04 SUBMISSION

More information

AASHTO s National Transportation Product Evaluation Program (NTPEP) Evaluation Program for Plants Producing Geotextiles. Pre-Audit Application Form

AASHTO s National Transportation Product Evaluation Program (NTPEP) Evaluation Program for Plants Producing Geotextiles. Pre-Audit Application Form Please provide the following information and return responses to AASHTO. Provide all applicable supporting documentation requested. Plant Name: Physical Address: Mailing Address: (if different from above)

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames.

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames. 2 Pine Trees, Chertsey Lane, Staines-upon-Thames. TW18 3HR Unit 8B, B W Estates Oldmixon Crescent Weston-super-Mare North Somerset BS24 9BA Contact: Mr K D James Tel: +44 (0)1934-644866 Fax: +44 (0)1934-413909

More information

CE TYPE EXAMINATION CERTIFICATE

CE TYPE EXAMINATION CERTIFICATE In application of the directive 89/686/EEG of 21 December 1989 concerning the harmonisation of the Member States legislation relative to personal protective equipment, Centexbel Notified body 0493 authorised

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Bucknalls Lane Garston Watford Hertfordshire WD25 9BA Contact: Alvaro Enquita-Gonzalez Tel: +44 (0)1923-665350 Fax: +44 (0)1923-665452 E-Mail:

More information

SKAPS GEOTEXTILE SUBSURFACE DRAINAGE

SKAPS GEOTEXTILE SUBSURFACE DRAINAGE SKAPS INDUSTRIES 335 Athena Drive, Athens, GA 30601 Ph: (706)-354-3700 Fax: (706)-354-3737 Email: contact@skaps.com DROP-IN SPECIFICATIONS SKAPS GEOTEXTILE SUBSURFACE DRAINAGE The following drop-in specification

More information

Annex of the certificate (Page 1/5) Accreditation Scope

Annex of the certificate (Page 1/5) Accreditation Scope Annex of the certificate (Page 1/5) Accreditation Scope As a Testing Laboratory Tested Materials / Products EX LABORATORY Metallic materials Construction products Address: Küçük Çiğli Mh. 8780/1 Sk. No:5

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Presley House Presley Way Crownhill Milton Keynes MK8 0ES United Kingdom Contact: Jeremy Hodge Tel: +44 (0) 1908 267300 Fax: +44 (0) 1908

More information

Joint Stock Company Alzida Savanorių pr. 221, LT Vilnius, Lithuania

Joint Stock Company Alzida Savanorių pr. 221, LT Vilnius, Lithuania page 1 (13) Joint Stock Company Alzida Savanorių pr. 221, LT- 02300 Vilnius, Lithuania SCOPE OF ACCREDITATION (flexible) No. Name of the testing object Name of the parameters (characteristics) to be tested

More information

Woolmark Specification

Woolmark Specification SPECIFICATION AF-1: 2016 Woolmark Specification WOOL-FILLED APPAREL PRODUCTS PRODUCTS Woolmark and Woolmark Blend labelling may be applied to products provided they meet the requirements of this specification.

More information

The Laboratory is qualified to update standards identifying the test procedures.

The Laboratory is qualified to update standards identifying the test procedures. Page 1 of 19 The Laboratory is qualified to update standards identifying the test procedures. Tests: 2/1 Tensile test at ambient temperature IP No. 07002T001 (ČSN EN ISO 6892-1, ČSN EN ISO 15630-1, 2,

More information

STS Directory Accreditation number: STS 0030

STS Directory Accreditation number: STS 0030 International standard: ISO/IEC 17025:2005 Swiss standard: SN EN ISO/IEC 17025:2005 BSL Baustofflabor AG Postgässli 23a 3661 Uetendorf Head: Felix Solcà Responsible for MS: Dr. Benjamin Kaeser Telephone:

More information

RIA Technical Bulletins Index

RIA Technical Bulletins Index RIA Technical Bulletins Index You may download any of these technical bulletins by visiting our Dropbox page: https://www.dropbox.com/sh/xvbrv51d3tsxhs1/aadolgr_lznciac954tjo07ma?dl=0. FIBERS, YARNS, AND

More information

Geosynthetic Institute GSI GRI GT13(b) ISO Version

Geosynthetic Institute GSI GRI GT13(b) ISO Version Geosynthetic Institute 475 Kedron Avenue Folsom, PA 19033-1208 USA TEL (610) 522-8440 FAX (610) 522-8441 GEI GRI GSI GAI GCI GII Revision 1: December 19, 2012 Revision Schedule on pg. 9 GRI GT13(b) ISO

More information

The Laboratory is qualified to update standards identifying the test procedures.

The Laboratory is qualified to update standards identifying the test procedures. Page 1 of 17 The Laboratory is qualified to update standards identifying the test procedures. Tests: 2/1 Tensile test at ambient temperature IP No. 07002T001 (ČSN EN ISO 6892-1, ČSN EN ISO 15630-1, 2,

More information

TECHNICAL BULLETIN Weston Parkway, Cary, North Carolina, Telephone (919) FLAMMABILITY TESTING: A REVIEW BY COTTON INCORPORATED

TECHNICAL BULLETIN Weston Parkway, Cary, North Carolina, Telephone (919) FLAMMABILITY TESTING: A REVIEW BY COTTON INCORPORATED TECHNICAL BULLETIN 6399 Weston Parkway, Cary, North Carolina, 27513 Telephone (919) 678-2220 TRI 4004 FLAMMABILITY TESTING: A REVIEW BY COTTON INCORPORATED 2004 Cotton Incorporated. All rights reserved;

More information

Flame-retardant properties: Additional use: Care: Washing (length shrinkage): Dry cleaning (length shrinkage): 0.5% Pilling: Light fastness:

Flame-retardant properties: Additional use: Care: Washing (length shrinkage): Dry cleaning (length shrinkage): 0.5% Pilling: Light fastness: AREZZO IV Upholstery fabric; Arezzo IV with its textured surface and clear colouring is a true upholstery classic. The hard wearing basic is in easy care Trevira CS with a lovely feel thanks to the use

More information

Flame-retardant properties: Additional use: Care: Washing (length shrinkage): Dry cleaning (length shrinkage): 1% Pilling: Certificates / tests:

Flame-retardant properties: Additional use: Care: Washing (length shrinkage): Dry cleaning (length shrinkage): 1% Pilling: Certificates / tests: LORD III Dense curtain fabric; Mottled basic article in Trevira CS. Lord III captivates with a soft drape quality and a textured surface. The hardwearing fabric with good sound absorption can be used for

More information

American Railway Engineering and Maintenance of Way Association Letter Ballot

American Railway Engineering and Maintenance of Way Association Letter Ballot American Railway Engineering and Maintenance of Way Association Letter Ballot 1. Committee and Subcommittee: Committee 1, Roadway and Ballast, Subcommittee 10, Geosynthetics 2. Letter Ballot Number: 01-18-05

More information

Care and Cleaning Recommendations for Mount Vernon FR Flame Resistant Fabrics

Care and Cleaning Recommendations for Mount Vernon FR Flame Resistant Fabrics Mount Vernon Mills, Inc. 91 Fourth St. Trion, GA 30753 (706) 734-2311 www.mvmfr.com mvmfr@mvmills.com Care and Cleaning Recommendations for Mount Vernon FR Flame Resistant Fabrics Mount Vernon Mills, Inc.

More information

Civil engineering Fibertex Geotextiles

Civil engineering Fibertex Geotextiles C O N S T R U C T I O N 100.01 Civil engineering C O N S T R Constructing with Since the 1960s, nonwoven geotextiles have been used in many different foundation structures within civil engineering works.

More information

STS Directory Accreditation number: STS 0021

STS Directory Accreditation number: STS 0021 International standard: ISO/IEC 17025:2005 Swiss standard: SN EN ISO/IEC 17025:2005 LPM AG Labor für Prüfung und Materialtechnologie Tannenweg 10 5712 Beinwil am See Head: Responsible for MS: Ruedi Herren

More information

Annex of the certificate (Page 1/7) Accreditation Scope

Annex of the certificate (Page 1/7) Accreditation Scope Annex of the certificate (Page 1/7) As a Testing Laboratory Address: Organize Sanayi Bölgesi 10. Cadde No: 4 Melikgazi 38070 KAYSERİ/TÜRKİYE Phone : 90 352 321 11 06 Fax : 90 352 321 15 69 E-Mail : kayserilab@tse.org.tr

More information

SPECIAL SPECIFICATION 3687 Impermeable Liner

SPECIAL SPECIFICATION 3687 Impermeable Liner 1993 Specifications CSJ s 0569-01-043 & 0945-04-025 SPECIAL SPECIFICATION 3687 Impermeable Liner 1. Description. This Item shall govern for the furnishing and installation of the impermeable liner (geomembrane)

More information

1993 Specifications CSJ SPECIAL SPECIFICATION ITEM Impermeable Liner

1993 Specifications CSJ SPECIAL SPECIFICATION ITEM Impermeable Liner 1993 Specifications CSJ 0128-01-085 SPECIAL SPECIFICATION ITEM 5327 Impermeable Liner 1. Description. This Item shall govern for the furnishing and installation of the impermeable liner (geomembrane) shown

More information

LiteEarth Advanced Synthetic Grass Geomembrane Liner INDEPENDENT THIRD PARTY PERFORMANCE TESTING REPORT. U.S. Patent No.

LiteEarth Advanced Synthetic Grass Geomembrane Liner INDEPENDENT THIRD PARTY PERFORMANCE TESTING REPORT. U.S. Patent No. LiteEarth Advanced Synthetic Grass Geomembrane Liner INDEPENDENT THIRD PARTY PERFORMANCE TESTING REPORT U.S. Patent No. 9151009 B2 Contents 1.0 INTRODUCTION...4 2.0 INDEX AND QUALITY CONTROL TESTS 2.1

More information

ISO Textiles Domestic washing and drying procedures for textile testing

ISO Textiles Domestic washing and drying procedures for textile testing INTERNATIONAL STANDARD ISO 6330 Third edition 2012-04-15 Textiles Domestic washing and drying procedures for textile testing Textiles Méthodes de lavage et de séchage domestiques en vue des essais des

More information

Section 714. GEOTEXTILE AND GEOCOMPOSITE DRAIN MATERIAL

Section 714. GEOTEXTILE AND GEOCOMPOSITE DRAIN MATERIAL Section 714. GEOTEXTILE AND GEOCOMPOSITE DRAIN MATERIAL 714.01 Geotextile. Use long-chain, synthetic polymers, composed at least 95 percent by mass of polyolefins or polyesters, to manufacture geotextile

More information

Drop-In Specifications INTEGRATED DRAINAGE SYSTEM GEOMEMBRANE

Drop-In Specifications INTEGRATED DRAINAGE SYSTEM GEOMEMBRANE Drop-In Specifications INTEGRATED DRAINAGE SYSTEM GEOMEMBRANE The following specification is a sample guideline to be customized by the engineer for preparing site specific specification. This information

More information

MATERIAL SPECIFICATION FOR GEOTEXTILES

MATERIAL SPECIFICATION FOR GEOTEXTILES ONTARIO PROVINCIAL STANDARD SPECIFICATION OPSS.MUNI 1860 November 2018 MATERIAL SPECIFICATION FOR GEOTEXTILES TABLE OF CONTENTS 1860.01 SCOPE 1860.02 REFERENCES 1860.03 DEFINITIONS 1860.04 DESIGN AND SUBMISSION

More information

SINFONIA CS V col 1012/1013

SINFONIA CS V col 1012/1013 SINFONIA CS V col 1012/1013 Semi transparent curtain fabric; soft and beautifully draping classic in Trevira CS. A best selling fabric with a comprehensive colour palette, which can be combined with other

More information

Aggregates Table 1 No. Title Options

Aggregates Table 1 No. Title Options Aggregates Table 1 BS EN 932-1 Methods for sampling From stockpiles BS EN 932-2 Methods for reducing laboratory samples BS EN 932-3 BS EN 933-1 BS EN 933-2 Procedure and terminology for simplified petrographic

More information

SECTION TABLE OF CONTENTS GEOTEXTILE TUBES PARAGRAPH TITLE PAGE NOS.

SECTION TABLE OF CONTENTS GEOTEXTILE TUBES PARAGRAPH TITLE PAGE NOS. SECTION TABLE OF CONTENTS SITE WORK GEOTEXTILE TUBES PARAGRAPH TITLE PAGE NOS. PART 1 - GENERAL 1.1 SCOPE OF WORK................................ 1 1.2 REFERENCES.................................. 1 1.3

More information

SMARTREPEL HYDRO AM. Fluorine-free repellents. Public, Smartrepel Hydro Georg Lang, Textile Specialties Business, /

SMARTREPEL HYDRO AM. Fluorine-free repellents. Public, Smartrepel Hydro Georg Lang, Textile Specialties Business, / SMARTREPEL HYDRO AM Fluorine-free repellents 1 / Smartrepel Hydro - PFC-Free Protection Palette Smartrepel Hydro Nature-friendlier protection that keeps you dry: Microencapsulated chemistry Highly biodegradable

More information

Civil engineering Fibertex Geotextiles

Civil engineering Fibertex Geotextiles C O N S T R U C T I O N 100.06 Civil engineering C O N S T R Constructing with Fibertex offers a full range of nonwoven geotextiles designed for use in many different foundation structures within civil

More information

ON FIRE OF QUALITY: SINCE 1972 A CONTINUUM

ON FIRE OF QUALITY: SINCE 1972 A CONTINUUM A CONTINUUM OF QUALITY: ON FIRE SINCE 1972 The Govmark Organization, Inc. Instrument Division (the largest USA manufacturer of fire and flammability test instrumentation worldwide) has been producing high

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, Wyndham Way Telford Way Industrial Estate Kettering NN16 8SD Contact: Mrs J Glasspool Tel: +44 (0)1536 410000 Fax: +44 (0)1536 410626 E-Mail:

More information

RG1,5SA Self Adhesive

RG1,5SA Self Adhesive Description of Product: Self adhesive membrane with a thickness of 1.5mm, consisting of rubberized bitumen with adhesive additives, glassfiber carrier, removable PP film at bottom and high density polyethylene

More information

TECHNICAL BULLETIN Weston Parkway, Cary, North Carolina, Telephone (919)

TECHNICAL BULLETIN Weston Parkway, Cary, North Carolina, Telephone (919) TECHNICAL BULLETIN 6399 Weston Parkway, Cary, North Carolina, 27513 Telephone (919) 678-2220 TRI 3013 WRINKLE-RESISTANT FINISHING OF COTTON FABRICS AND GARMENTS 2000 Cotton Incorporated. All rights reserved;

More information

Leather descriptions and technical informations

Leather descriptions and technical informations THE LUXPEL GROUP via Angelo Butturini 10 Verona, VR 37126 - ITALIA Tel +39 045 8325761 E-mail: info@luxpel.it Leather descriptions and technical informations Product description Luxpel Natural Wash Leather

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Building 63 Haslar Marine Technology Park Haslar Road Gosport Hampshire PO12 2AG Contact: Mr S Kumar Tel: +44 (0) 208 692 5050 Fax: +44 (0)

More information

Flame-retardant properties: Additional use: Care: Washing (length shrinkage): 1% Washing (length shrinkage): 0.5% Dry cleaning (length shrinkage): 1%

Flame-retardant properties: Additional use: Care: Washing (length shrinkage): 1% Washing (length shrinkage): 0.5% Dry cleaning (length shrinkage): 1% SECRET Textured dim-out fabric with a 300 cm wide width; Secret captivates with a natural, linen like weave texture on the facing side and a dense, satin like uni surface for darkening interiors on the

More information

Flame-retardant properties: Additional use: Care: Washing (length shrinkage): Dry cleaning (length shrinkage): 1.5% Pilling: Certificates / tests:

Flame-retardant properties: Additional use: Care: Washing (length shrinkage): Dry cleaning (length shrinkage): 1.5% Pilling: Certificates / tests: MARLA Decoration fabric in Trevira CS; the surfaces of the circles overlapping into one another lend this two-coloured fabric the impression of depth. Can be combined with the plain coloured structured

More information

Flame-retardant properties: Additional use: Care: Washing (length shrinkage): Dry cleaning (length shrinkage): 1% Certificates / tests:

Flame-retardant properties: Additional use: Care: Washing (length shrinkage): Dry cleaning (length shrinkage): 1% Certificates / tests: LERIDA IV High quality decoration fabric in Trevira CS. The piece dyed fabric in a satin weave has an elegant lustre. The well-established classic is highly versatile. It is available in 37 contemporary

More information

Flame-retardant properties: Additional use: Care: Dry cleaning (length shrinkage): 1% Certificates / tests:

Flame-retardant properties: Additional use: Care: Dry cleaning (length shrinkage): 1% Certificates / tests: SHADE IV -300 Glare and heat protection; The screen-like weave in a transparent finish offers effective glare and sun protection with optimised exterior vistas. An ideal solution for controlling light

More information

11/2016. Protective clothing BUSHFIRE. 3rd category of Personal Protective Clothing

11/2016. Protective clothing BUSHFIRE. 3rd category of Personal Protective Clothing 11/2016 Protective clothing BUSHFIRE 3rd category of Personal Protective Clothing 1 Design of product: 2 Used materials and their technical parameters: Art. 1117 NOMEX Comfort RS, 220 g/m2 (93% Nomex,

More information

BRICK. Upholstery fabric. Number of colours: Special colours available from 200 m / 220 yds upwards. 25% Polyamide 5% Polyester

BRICK. Upholstery fabric. Number of colours: Special colours available from 200 m / 220 yds upwards. 25% Polyamide 5% Polyester BRICK Upholstery fabric; The look of this heavy upholstery fabric is unique and original. The sophisticated jacquard technique lets the lines of the bold, organic design come to the fore, making it three

More information

SHADE MEDIUM R. Roller blinds. Number of colours: 5 Special colours available from 240 m / 260 yds upwards. 100% Flameretardant polyester (Trevira CS)

SHADE MEDIUM R. Roller blinds. Number of colours: 5 Special colours available from 240 m / 260 yds upwards. 100% Flameretardant polyester (Trevira CS) SHADE MEDIUM R Roller blind fabric; The screen-like weave in a semi-transparent finish offers effective glare and sun protection with optimised exterior vistas. An ideal solution for controlling light

More information

Delivering the Comfort and Performance Your Customers Demand

Delivering the Comfort and Performance Your Customers Demand Delivering the Comfort and Performance Your Customers Demand Innovative Products Leading the way in textile testing solutions SDL Atlas is the leading supplier of textile testing equipment, laboratory

More information

ANSI-ASQ National Accreditation Board/ACLASS

ANSI-ASQ National Accreditation Board/ACLASS ANSI-ASQ National Accreditation Board/ACLASS SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 UL Verification Services Inc. 1559 King Street Enfield, CT 06082 www.ul.com/consumer-products Point of Contact:

More information

ECO-FRIENDLY PROTECTING AND CLEANING SOLUTIONS

ECO-FRIENDLY PROTECTING AND CLEANING SOLUTIONS ECO-FRIENDLY PROTECTING AND CLEANING SOLUTIONS WE MAKE YOUR LIFE EASIER CLOTHING CARE INDOOR FURNITURE Softcare products include everything you need to keep indoor furniture and interiors well maintained

More information

Flame-retardant properties: Additional use: Care: Washing (length shrinkage): Dry cleaning (length shrinkage): 1.5% Pilling: Certificates / tests:

Flame-retardant properties: Additional use: Care: Washing (length shrinkage): Dry cleaning (length shrinkage): 1.5% Pilling: Certificates / tests: ASTRA II Upholstery fabric; Soft, hard wearing distance weave in Trevira CS for areas of heavy use in the contract sector. Two layers of weaves are linked together with fine monofil threads to bestow volume

More information

Flame-retardant properties: Additional use: Care: Washing (length shrinkage): Dry cleaning (length shrinkage): 1% Light fastness:

Flame-retardant properties: Additional use: Care: Washing (length shrinkage): Dry cleaning (length shrinkage): 1% Light fastness: SCHERZO V Semi-transparent curtain fabric in Trevira CS; The hallmark of this classic is an elegant, semi-transparent and textured quality which is reminiscent of light linen fabrics. The colour palette

More information

FIBRELOC CARPET AND UPHOLSTERY PROTECTOR WITH DURABLE STAIN SHIELDING AND WET SPILL BEADING

FIBRELOC CARPET AND UPHOLSTERY PROTECTOR WITH DURABLE STAIN SHIELDING AND WET SPILL BEADING Page 52 of 62 FIBRELOC CARPET AND UPHOLSTERY PROTECTOR WITH DURABLE STAIN SHIELDING AND WET SPILL BEADING Product Description A new type of Fluorocarbon protector that uses new fibre locking technology

More information

It is possible to remove most gum and/or tar by using De-Solve-It, a citrus based solvent available from Mountville Mills.

It is possible to remove most gum and/or tar by using De-Solve-It, a citrus based solvent available from Mountville Mills. BORDER CUTS, SPLITS OR TEARS Gaps between the dryer basket and housing - Cure for this is to use proper gaskets supplied by equipment manufacturer and to insure basket supports are properly adjusted. Customer

More information

Y S L V i z L i t e 3 0 2

Y S L V i z L i t e 3 0 2 Product Information is intended for use on Flame retardant PPE clothing such as High Visibility Warning clothing and Fire Fighting clothing to enhance visibility in low light and night time conditions

More information

Flame-retardant properties: Additional use: Care: Washing (length shrinkage): 0.5% Dry cleaning (length shrinkage): 0.5% Certificates / tests:

Flame-retardant properties: Additional use: Care: Washing (length shrinkage): 0.5% Dry cleaning (length shrinkage): 0.5% Certificates / tests: SAPHIR CRASH II Semi-transparent curtain fabric; Three-dimensional crush effect in combination with a two tonality changeant effect. Subtly harmonised natural tones create a range of elegant and luxurious

More information

Flame-retardant properties: Additional use: Care: Washing (length shrinkage): 1% Dry cleaning (length shrinkage): 1.5% Certificates / tests:

Flame-retardant properties: Additional use: Care: Washing (length shrinkage): 1% Dry cleaning (length shrinkage): 1.5% Certificates / tests: DELTACOUSTIC Semi-transparent curtain fabric with sound absorption properties. The ultra-technical weave with its natural matt shimmering surface is available in colours which were inspired by nature bestowing

More information

AITA. High headrest chair S bb-00yy. High chair S bb-00yy. Low chair S bb-00yy. 4 polished aluminium base high chair S bb-00yy

AITA. High headrest chair S bb-00yy. High chair S bb-00yy. Low chair S bb-00yy. 4 polished aluminium base high chair S bb-00yy Aita 2 AITA Designed by Aitor García de Vicuña, the AITA Designed is a balance between surroundings and timeless aesthetic.it is a fit for everyone, a solution to the demands of new architectures and spaces

More information

BS EN ISO : 2010

BS EN ISO : 2010 Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 (0 1925 655116 F : +44 (0) 1925 655419 E : warrington@exova.com W: www.exova.com BS EN ISO 92391: 2010 Fire Tests For Determination

More information

SPOK. Semi-transparent curtain fabric. Number of colours: Special colours available from 1000 m / 1090 yds upwards.

SPOK. Semi-transparent curtain fabric. Number of colours: Special colours available from 1000 m / 1090 yds upwards. SPOK Exceptional curtain fabric; The papery feel of this non woven fabric in Trevira CS derives from the method of manufacture. Length wise and cross wise running fibres are laid down and stuck together

More information

AASHTO M Subsurface Drainage

AASHTO M Subsurface Drainage Subsurface Drainage Description: This specification is applicable to placing a geotextile against the soil to allow long-term passage of water into a subsurface drain system retaining the in -situ soil.

More information

Flame-retardant properties: Additional use: Care: Washing (length shrinkage): Dry cleaning (length shrinkage): 0.5% Certificates / tests:

Flame-retardant properties: Additional use: Care: Washing (length shrinkage): Dry cleaning (length shrinkage): 0.5% Certificates / tests: ALPHACOUSTIC Transparent curtain fabric with an understated architectural look. The subtle rib texture, which flirts with depth effects is also responsible for the exceptionally good sound absorption coefficient

More information

Number of colours: Additional use: Care: Washing (length shrinkage): Dry cleaning (length shrinkage): 1% Pilling: Certificates / tests:

Number of colours: Additional use: Care: Washing (length shrinkage): Dry cleaning (length shrinkage): 1% Pilling: Certificates / tests: ULTRA V col 121 Decoration fabric; The understated basic with its comprehensive colour palette and dry feel is suitable for various applications. Owing to its ecological manufacture, the Ultra V is also

More information

8/2017. Firefighter protective clothing ANACONDA. 3rd category of Personal Protective Clothing

8/2017. Firefighter protective clothing ANACONDA. 3rd category of Personal Protective Clothing 8/2017 Firefighter protective clothing ANACONDA 3rd category of Personal Protective Clothing 1 Clothing image: 2 Clothing image: Description of used materials and their technical parameters: Garment features:

More information

SPIDER P SPIDER P mineral

SPIDER P SPIDER P mineral The leader in the selfadhesive technology! SPIDER P SPIDER P mineral SPIDER P and SPIDER P MINERAL are excellent quality self-adhesive waterproofing membranes made with ADESO technology, the new compound

More information

Inherently Flame Retardant and Resistant Fibres

Inherently Flame Retardant and Resistant Fibres Front Cover image supplied courtesy of Glanzstoff Inherently Flame Retardant and Resistant Fibres Inherently Flame Retardant and Resistant Fibres Av E. Van Nieuwenhuyse 6 Tel. +32 (2) 676 74 55 info@cirfs.org

More information

Flame-retardant properties: Additional use: Care: Washing (length shrinkage): 0.5% Dry cleaning (length shrinkage): 1% Certificates / tests:

Flame-retardant properties: Additional use: Care: Washing (length shrinkage): 0.5% Dry cleaning (length shrinkage): 1% Certificates / tests: SOPRANO COLOR II Curtain fabric; Highly transparent weave in Trevira CS with a soft feel and flowing drape qualities. Beautifully light, non crease and easy care Soprano is one of the most important flame

More information

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005 Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate D-PL-11035-03-00 according to DIN EN ISO/IEC 17025:2005 Period of validity: 25.10.2017 to 24.10.2022 Holder of certificate: DMT

More information

Number of colours: 5. Flame-retardant properties: Additional use: Certificates / tests:

Number of colours: 5. Flame-retardant properties: Additional use: Certificates / tests: DENSO R Roller blind fabric; Opaque with black out function. This black out fabric was specially developed for use with extra wide roller blinds on large expanses. Use: Roller blinds Number of colours:

More information

Flame-retardant properties: Additional use: Care: Washing (length shrinkage): 0.5% Dry cleaning (length shrinkage): 1% Certificates / tests:

Flame-retardant properties: Additional use: Care: Washing (length shrinkage): 0.5% Dry cleaning (length shrinkage): 1% Certificates / tests: SOLISTA COLOR II Sheer curtain fabric with a delicate flame texture along with fluid and light drape properties and a soft knitter-free feel. The easy care item is versatile for use in residential furnishing

More information

Care: Washing (length shrinkage): Dry cleaning (length shrinkage): 1.5% Certificates / tests:

Care: Washing (length shrinkage): Dry cleaning (length shrinkage): 1.5% Certificates / tests: VELLING Upholstery fabric; velour, available in various discreet shades. Use: Upholstery fabric Number of colours: 60 Special colours available from 180 m / 200 yds upwards. Material: 100% Cotton Fabric

More information

Flame-retardant properties: Additional use: Care: Washing (length shrinkage): 0.5% Dry cleaning (length shrinkage): 1% Certificates / tests:

Flame-retardant properties: Additional use: Care: Washing (length shrinkage): 0.5% Dry cleaning (length shrinkage): 1% Certificates / tests: SINFONIA CS ADAGIO Semi transparent curtain fabric in Trevira CS with fil coupé. Spreading across the entire width, a second weft thread system adds attractive markings on the base of the best selling

More information

Flame-retardant properties: Additional use: Care: Washing (length shrinkage): 2% Certificates / tests:

Flame-retardant properties: Additional use: Care: Washing (length shrinkage): 2% Certificates / tests: OLA Curtain fabric; can be used on both sides, high quality jacquard based on Trevira CS. The pattern of waves in combination with the satin elements makes this fabric feminine and elegant. Natural appearance

More information

Semi-transparent curtain fabric; Linen weave in a 300 cm wide width and with quiet stripes. Number of colours: Additional use: Care:

Semi-transparent curtain fabric; Linen weave in a 300 cm wide width and with quiet stripes. Number of colours: Additional use: Care: MYKONOS II Semi-transparent curtain fabric; Linen weave in a 300 cm wide width and with quiet stripes. Use: Semi-transparent curtain fabric Number of colours: 1 Material: 100% Linen Fabric width: 300 cm/118

More information

Fiji Electricity Authority Transmission Unit 2 Marlow Street, Suva

Fiji Electricity Authority Transmission Unit 2 Marlow Street, Suva TENDER DOCUMENT AND SPECIFICATION MR 269/2017 Preferred Supplier for Geotextile Fabric The Fiji Electricity Authority (FEA) invites bids from reputable contractors for being the Preferred Supplier of Geotextile

More information

BTHA List of Safety Standards that may be applicable to Toys Updated 25/07/2018

BTHA List of Safety Standards that may be applicable to Toys Updated 25/07/2018 BTHA List of Safety Standards that may be applicable to Toys Standard Number Description Updated 25/07/2018 Toy Safety BS EN 62115:2005 + A11: 2012 Safety of Toys. Electrical Toys - Safety BS EN71-1: 2014+A1:

More information

Number of colours: Additional use: Care: Dry cleaning (length shrinkage): 1.5% Certificates / tests:

Number of colours: Additional use: Care: Dry cleaning (length shrinkage): 1.5% Certificates / tests: DIMOS STRIPE Striking curtain fabric with a sophisticated stripe effect. A black thread in the direction of the warp creates a refined classic stripe which assumes a slightly irregular look because of

More information

Geomembranes that work

Geomembranes that work Geomembranes that work www.firestonebpe.com Dependable performance in demanding environments Firestone EPDM Geomembrane is a rubber liner offering a flexible and durable solution for a wide variety of

More information

INDIVA. Semi-transparent curtain fabric. Number of colours: 100% Flameretardant polyester (Trevira CS) Height: cm/56 inch/1.

INDIVA. Semi-transparent curtain fabric. Number of colours: 100% Flameretardant polyester (Trevira CS) Height: cm/56 inch/1. INDIVA Semi-transparent curtain fabric in Trevira CS. Decorative, double-layer fabric with colourful blossoms that seem to float on a background of leave twigs. Use: Semi-transparent curtain fabric Number

More information

Flame-retardant properties: Additional use: Care: Washing (length shrinkage): Dry cleaning (length shrinkage): 0.

Flame-retardant properties: Additional use: Care: Washing (length shrinkage): Dry cleaning (length shrinkage): 0. BETACOUSTIC Transparent curtain fabric; The surface texture of this item is voluminous and the hallmark of this fabric. With an exceptional sound absorption coefficient of Alpha value 0.65 it is suitable

More information

Leak Location Geosynthetic Materials in Base Liner Systems. NY Federation SWANA. May, 2014

Leak Location Geosynthetic Materials in Base Liner Systems. NY Federation SWANA. May, 2014 Leak Location Geosynthetic Materials in Base Liner Systems NY Federation SWANA May, 2014 Different ELI Surveys A. Covered Electrical Liner Integrity (ELI) Survey Dipole Method Suitable for water or soil

More information