GLOBAL FIRE EQUIPMENT JUNO-NET EN-54. Fire Alarm Control Panel INSTALLATION & COMMISSIONING MANUAL

Size: px
Start display at page:

Download "GLOBAL FIRE EQUIPMENT JUNO-NET EN-54. Fire Alarm Control Panel INSTALLATION & COMMISSIONING MANUAL"

Transcription

1 EN-54 Fire Alarm ontrol Panel INSTALLATION & OMMISSIONING MANUAL OT. 4, 2005 REVISION 1.1

2 ONTENTS OVERVIEW Introduction... EN-54 Information and Key Features... Typical System Schematic... Typical System Block Diagram... Power Requirements... Battery Requirements... Identifying omponents... Recommended ables... Analogue Loops, onventional Sounders and Data Loops... Limitations... Definitions... INSTALLATION Introduction... Main Panel... Mains Power onnection... Other Main Panel connections... Integrated Sub-panels... Repeaters... Mains Power onnection... Integrated Sub-panels... Standard Sub-panels... Data Loops... Main Panel RS Data Loop Interface onfiguration... Repeater RS Standard Sub-panel RS RS485 External onnection... onnection Schematic for Self-ontained Panels... onnection Schematic for Main Panel to External Sub-Panel(s)... onnection Schematic for Main Panel to External Sub-Panel(s) using RS onnection Schematic for Panel, Repeater and Sub-Panel using Fibre Optics... onnection Schematic for Main Panel to Repeater Panel(s) using RS Main Panel Fibre Optic... Repeater Fibre Optic... Fibre Optic External onnection... Analogue Loops... onventional Sounders... Fire Relays... Relay Drive Outputs... Fire Brigade Transmission... Printer... Main Panel Batteries... Sub-panel Batteries... P Graphics Software... (EN-54) INSTALLATION & OMMISSIONING MANUAL REVISION 1.1 OT 4,

3 OMMISSIONING ONTENTS Introduction... The Main Panel Buttons... Getting The Main Panel Running... Getting A Repeater Running... Getting A Standard Sub-panel Running... Setting Panel Addresses And Types... Main Panel Integrated Sub-panel... Repeater Integrated Sub-panel... Standard Sub-panels... Getting Into Programming Mode... onnecting a PS2 Keyboard to the Main Panel... The IR Keypad Keys... Help... Logging In... Function Selection... Getting The System Running... ommunications heck... Main Panel heck... Learning Which Devices Are Fitted... Sounder Audibility heck... Main Panel... Standard Sub-panels... Integrated Sub-panels... Analogue Loop Monitoring... Open ircuit Test... Short ircuit Test... onventional Sounder Monitoring... Detector Tests... Detector Tests By Zone... Unassigned Detector Test... Wrapping Up Installation And ommissioning... Battery Fault Message Test... Power Failure Test... Master Reset... ADVANED FUNTIONALITY Programming Functions General... omplete List Of Functions... Keys To Use Within Functions... Help... QUART... General (EN-54) INSTALLATION & OMMISSIONING MANUAL REVISION 1.1 OT 4,

4 Specific Functions ONTENTS 1 Review Historic Log Display Historic Log Print Historic Log Entries lear Historic Log Print Loop/Device Set-up Read/lear Autostart ount Text Descriptions & Names Enter Device Text Enter Zone Text Enter ompany Name Zones - Disable & Assign Disable Zones Assign Sounder Groups to Zones Assign I/O Groups to Zones Assign Zone to Device Zone Sounder Delay Set-up Zone Fire Brigade Delay Set-up Set BMS Zone Numbers Sounders - Disable & Assign Sounder onfiguration onfigure Sounder Groups Disable Sounders Assign Sounder Group to Device Inhibit Sounders for Device Sounder Delay Set-up Override Sounder Delays Input/Output - Disable & Assign onfigure I/O Groups Select Fault I/O Group Assign I/O Group to Device Inhibit I/O for Device I/O Unit Action upon Evacuate I/O Unit Delay or Immediate I/O Delay Set-up (EN-54) INSTALLATION & OMMISSIONING MANUAL REVISION 1.1 OT 4,

5 ONTENTS 6 Device Set-up General Disable Loops Device Disable Set Selective Disablement Set Device Reporting Details Set Immediate Evacuate for Device Device Activation Overrides Delays Inhibit Auxiliary Relays Global Sensitivity Set-up onfigure Timed Sensitivity Other device options Select Device Heat Grade Select Device Smoke Sensitivity Removed - No longer available 6-4 Automatic Address Setting (SAM) Activate ASET Mode (SAM) lear Loop lear Device... Trouble shooting SAM Monitor Device ounts & Test Device ount, Type & Value Test Sounders Sounders on Test Activation Test Zones Sub-Panel LED Test Light LED on device (EN-54) INSTALLATION & OMMISSIONING MANUAL REVISION 1.1 OT 4,

6 ONTENTS 8 General Time/Date & Timers Set Date & Time Define Day & Night Delays Off at Night onfigure Evacuate Timer Device Starts Evacuate Timer Fire Brigade Delay Set-up Special Features Set-up Two Devices to Evacuate all Points to Evacuate Memory - BEWARE, ENGINEERS ONLY lear ustomer Flash Memory lear Non-Volatile RAM alculate ustomer Flash hecksum alculate Program Flash hecksum Other Features Active/Installation Mode Upload/Download Link to P The P Loader Software... The P JUNO Download Utility... The Main Panel... Uploading/Downloading ustomer Site Data Printer Disable/Enable Set User Access ode Set User Access Facilities Select language Removed - No longer available Set Installer Access ode Remote Access and Monitoring onfigure P Graphics Interface Modem Dial Out Number How The Dial Out Works Modem Initialization String TEHNIAL SPEIFIATIONS Main Panel Repeater Standard Sub-panel E DELARATION OF ONFORMITY (EN-54) INSTALLATION & OMMISSIONING MANUAL REVISION 1.1 OT 4,

7 OVERVIEW Introduction This document covers the installation and commissioning of a fire alarm system. This document is intended for use by a competent, qualified, fire alarm installation engineer. The fire alarm system is highly modular and each system should be tailored to the building requirements. The complete system should be designed to meet all applicable regulations. The installation must then be performed in accordance with the system design. This manual not only clarifies the components and connections during installation but will also assist in commissioning and maintenance. This manual covers the installation and commissioning of a complete system. There is a separate Operation and Maintenance Manual. ELETRO-STATI SENSITIVE DEVIES (ESD) TAKE SUITABLE ESD PREAUTIONS WHEN REMOVING OR INSTALLING PRINTED IRUIT BOARDS. All PBs contain Electrostatic Sensitive Devices. Take suitable ESD (Electrostatic Discharge) precautions when removing or installing printed circuit boards (PBs). (EN-54) INSTALLATION & OMMISSIONING MANUAL REVISION 1.1 OT 4,

8 OVERVIEW EN-54 Information In accordance with EN54 pt / A: 1999, clause 13.7, the maximum number of sensors and/or manual call points in this panel, will not exceed 512 units. This fire Detection ontrol Panel complies with the requirements of EN54 pt. 2 and / A: In addition to the requirements of the above mentioned standard, the unit conforms to the following optional functions: OPTION Indication ontrols Outputs EN54 pt.2 lause Fault Signals from points 8.3 Delays for activation of outputs 7.11 Disablement of each addressable point 9.5 Test ondition 10 Outputs to fire alarm devices 7.8 In addition to the functions required by the standard EN54 pt / A: 1999, the panel supports ancillary functions that are not required by the above mentioned standard, namely: Ancillary Functions: Panel network connection ports. Panel to P graphics software output port. Panel to P programming software (upload/download) port. Remote class change input extension board connector. Internal and External Printer. Auxiliary relays outputs. Key Features Fully expandable system - from 1 to 96 loops 125 device addresses per loop 96 VULAN (addressable) ultra low current base sounders per loop (32 address limit) 32 individually programmable sounder addresses per loop Full SAM and MAM support - Wizmart protocol only 2 Fire output relays (change-over) and 1 Fault relay (Normally losed) Open collector outputs for Fire, Fault and Pre-alarm remote indicators 2 conventional alarm outputs on each Main Panel, Repeater and Sub-panel (Individually programmable) Repeaters with optional Integrated Sub-panels (with one or three loops) All detector loops monitored for integrity 384 fully programmable zones 512 fully programmable sounder groups 512 Input and Output groups Event log (rolling, 2000 entries) ompatible with Apollo S90 /XP95, Discovery, Wizmart and Hochiki ESP Protocols ompatible with all our own low cost ancillary modules Backlit LD display with 4 rows of 40 characters Programming by panel keypad, infra-red remote keypad, P keyboard and Windows based "Loader" software Windows based P graphics software for alarm management and reporting Multiple language support (menu selectable) BMS output (RS232) (optional) Evacuate/lass hange input (optional) Multi-panel network by RS485 or fibre optic links Optional internal 40 column thermal printer Discovery functions: Only Apollo protocol Optional fire and fault LED zone indication (EN-54) INSTALLATION & OMMISSIONING MANUAL REVISION 1.1 OT 4,

9 Typical System Schematic OVERVIEW J-NET-ON FIB.OPT. / RS-485 ON 1 INT. SUB PANEL ON 5 TX RX LOADER ON 6 FIRE BRIG. AKNOWL. MAX 3A FAST ATING FLT FIR PAL N NO N NO N REPEATS FAULT AUX 2 AUX 1 ALL AUX RELAYS RATED AT V A/D 1 AMP RESISTIVE REPEATER FIRE FAULT MAX URRENT PER LAMP =ma PRE ALARM ON 2 ZONE LED AUX 1 PSU 0v 24v 0v PF E SF AUX 2 ZONE 0v PSU MPX BELL 1 BELL 2 EVA 24v BATT ON 7 EOL + 12V V LASS HANGE OR REMOTE EVA. POWER SUPPLY L E N 110V/230V A.. EOL 10K SND SND SND ON DET ON DET ON DET EOL 4K7 ION OPT ZMU ISO TMP BGU LSM ISO I/O + 24 V LOOP 1 LOOP 1 LOOP 2 LOOP 2 LOOP 3 LOOP 3 J-NET-LPON (EN-54) INSTALLATION & OMMISSIONING MANUAL REVISION 1.1 OT 4,

10 Typical System Block Diagram OVERVIEW GRAPHI SOFTWARE/MODEM BMS ONTROL PANEL LD LEDs 2 X SOUNDER PUTS SWITHES 2 X RELAY (FIRE) 1 X RELAY (FAULT) IR KEYBOARD PRINTER FIRE FAULT PRE-ALARM PS/2 P KEYBOARD PSU IN DATA LOOP 4 4 DATA LOOP IN 3 X LOOPS SUB-PANEL 2 X SOUNDER PUTS IR KEYBOARD PS/2 P KEYBOARD REPEATER UNIT LD SWITHES 2 X SOUNDER PUTS LEDs SUB-PANEL PSU 3 X LOOPS MAX 32 SUB-PANELS OPTIONS ARE SHOWN THUS (EN-54) INSTALLATION & OMMISSIONING MANUAL REVISION 1.1 OT 4,

11 Power Requirements OVERVIEW 1A F U S E 1A F U S E FASE NEUTRO FASE NEUTRO MEANWELL MODEL: PS INPUT: -240V A 1.5A /60Hz PUT: +27V 2.4A MEANWELL MODEL: LPP-1-27 INPUT: VA ; VD 47/63Hz PUT: +27V 5.6A DANGER 220 VOLTS DANGER 220 VOLTS 2.4A POWER SUPPLY UNIT 5.6A POWER SUPPLY UNIT Voltage urrent Primary supply voltage EM Standard VA EN522 class B EN60-4-2,3,4,5,6,8,11 EN60-3-2,3 2.4A PSU s recommended for 1 or 3 loop stand-alone or networked panels. 5.6A PSU s recommended for up to 9 loop self-contained or networked panels. The maximum alarm sounder current is the power supply current (2.4A or 5.6A) less the panel's alarm current. The maximum quiescent current per loop is 2mA. The loop short circuit (trip) current is 900mA. Battery Internal maximum 24V / 12AH (EN-54) INSTALLATION & OMMISSIONING MANUAL REVISION 1.1 OT 4,

12 Battery Requirements OVERVIEW The battery AH required are calculated from the following formula ( Quiescent current in ma of the panel with everything connected. X Standby time required in hours divided by 0. ) + ( Alarm current in Amps (sounder load) X Alarm time in hours ) + 20% Round up to the next available battery size. Quiescent currents for individual equipments are listed below: EQUIPMENT Main Panel 3 loop sub-panel Device on loop 24V auxiliary outputs (2 off) QUIESENT URRENT (ma) Refer to manufacturer's data Refer to connected devices ALARM URRENT (ma) Example A given installation has a 6 loop panel with 58mA detector load, 1.4A sounder load (including loop sounders) and a 24 hour standby requirement. ( Quiescent current in ma of the panel with everything connected. X Standby time required in hours divided by 0. ) + ( Alarm current in Amps (sounder load) X Alarm time in hours ) + 20% 130 (main panel) + 2 x 76 (6 loops) + 58 (detector load) 24 (standby in hrs) divided by 0 1 (main panel) + 2 x 105 (6 loops) + 58 (detector load) 0.5 (alarm time in hrs) ( = 340mA X = 8.16AH = 0.024H ) + ( + = 418mA +1.4A (sounder load) = 1.818A = AH +20% (1.81AH) = AH The next available battery size is 12AH X = 0.909AH = 0.5H ) (EN-54) INSTALLATION & OMMISSIONING MANUAL REVISION 1.1 OT 4,

13 Identifying omponents Panel boxes for Main Panels or Repeaters OVERVIEW FIRE Panel Box for 4 to 12 Loops 125 mm 5 mm FIRE Panel Box for 1 to 3 Loops 125 mm 370 mm 420 mm 340 mm (EN-54) INSTALLATION & OMMISSIONING MANUAL REVISION 1.1 OT 4,

14 FIRE FIRE ON 2 ZONE LED INT. SUB PANEL ON 5 TX RX AUX 1 PSU J2 J1 ON 6 FIRE BRIG. AKNOWL. 0v 24v 0v PF E SF AUX 2 ZONE 0v PSU MPX BELL 1 BELL 2 EVA MAX 3A FAST ATING 24v BATT RS 485 RS 485 IN TX 1 RX 2 RX 1 TX 2 A B A B A B A B FLT FIR PAL N NO N NO N ON 7 MAIN PANEL SUB PANEL or REPEATERS FIRE MEANWELL 1A F U S E FIRE 220 VOLTS NEUTRO ON 2 ZONE LED INT. SUB PANEL ON 5 TX RX AUX 1 PSU J2 J1 ETH ETH ETH ON 6 FIRE BRIG. AKNOWL. 0v 24v 0v PF E SF AUX 2 ZONE 0v PSU MPX BELL 1 BELL 2 EVA MPX N5 MPX N5 MPX N5 MAX 3A FAST ATING 24v BATT RS 485 RS 485 IN TX 1 RX 2 RX 1 TX 2 A B A B A B A B FLT FIR PAL N NO N NO N ON 7 MAIN PANEL SUB PANEL or REPEATERS FAULT FAULT FAULT FIRE FIRE FIRE MAX 3A FAST ATING MAX 3A FAST ATING MAX 3A FAST ATING EVA SILENE PANEL NO A ON EVA SILENE A PANEL ON NO EVA SILENE PANEL NO A ON MEANWELL 1A F U S E 220 VOLTS GLOBAL OVERVIEW Identifying omponents Panel boxes for Main Panels or Repeaters Inside a 1 to 12 Loop Self-ontained Panel Box FAULT FIRE ALARM SYSTEM FASE PRE-ALARM TEST DISABLED SYSTEM ON ALARM FAULT SU PLY FAULT PRO. FAULT JUNONET MANUFATURED TO THE REQUIREMENTS OF EN54 PT ALARM DISPLAY ALARM SILENE SYSTEM RESET AUXILIARY RELAYS FIRE BRIGADE TRANSMI SION FAULT QUEUE REVIEW TEST DISABLED LOOP 1 LOOP 1 LOOP 2 LOOP 2 LOOP 3 LOOP 3 MODEL: LPP-1-27 INPUT: VA ; VD 47/63Hz PUT: +27V 5.6A DANGER 5A POWER SUPPLY UNIT LOOP 1 LOOP 1 LOOP 2 LOOP 2 LOOP 3 LOOP 3 SNDR 1 SNDR 2 N4 N R7 35 OMMS OK OMMS FLT PRE-ALARM 5VOLTFAULT H8/3003 BATT 24V 0V 24V 0V 0V 28V 28V MON AUX PS POWER SUPPLY IN TRANS. FAULT SELETED LAMP TEST DETETORS FIRE BRIGADE ATIVE AKNOWLEDGED DELAYS PAPER F ED SOUND ALARMS RS485 INTERFAE LOOP 2 LOOP 2 LOOP 3 LOOP 3 LOOP 1 J-NET-ON FIB.OPT. / RS-485 ON 1 LOADER REPEATS FAULT AUX 2 AUX 1 LOOP 1 LOOP 1 LOOP 2 LOOP 2 LOOP 3 LOOP 3 SNDR 1 SNDR 2 N4 N R7 35 OMMS OK OMMS FLT PRE-ALARM 5VOLT FAULT H8/3003 BATT 24V 0V 24V 0V 0V 28V 28V MON AUX PS POWER SUPPLY IN J-NET-LPON J-NET-RS485-INT-NEW J-NET-SP with LOOP-ARD J-NET-SP with LOOP-ARD J1&J2OFF J-NET RS 485 INT. J1&J2ON N4 N R7 35 OMMS OK OMMS FLT PRE-ALARM 5 VOLT FAULT BATT 24V 0V 24V 0V 0V 28V 28V MON AUX PS POWER SUPPLY IN (OPTIONAL) Only used, if there are externally connected Sub-Panels LOOP 1 SNDR 1 SNDR 2 H8/3003 J-NET-SP with LOOP-ARD On both of these panels, the first 1 or 3 loops are found on the mainboard that is attached to the metallic fascia of the panel. FAULT PRE-ALARM FIRE ALARM SYSTEM FAULT FIRE Inside a 1 to 3 Loop Panel Box J-NET-ON FIB.OPT. / RS-485 ON 1 LOADER REPEATS FAULT AUX 2 AUX 1 FASE NEUTRO TEST DISABLED SYSTEM ON ALARM DISPLAY QUEUE REVIEW TEST J-NET-LPON LOOP 1 LOOP 1 LOOP 2 LOOP 2 MODEL: LPP-1-27 INPUT: VA ; VD 47/63Hz PUT: +27V 5.6A ALARM FAULT SU PLY FAULT PRO. FAULT TRANS. FAULT JUNONET MANUFATURED TO THE REQUIREMENTS OF EN54 PT FIRE BRIGADE AKNOWLEDGED ALARM SILENE SYSTEM RESET LAMP TEST AUXILIARY RELAYS FIRE BRIGADE TRANSMI SION SELETED DETETORS DISABLED LOOP 3 LOOP 3 J-NET-RS485-INT-NEW DANGER 5A POWER SUPPLY UNIT PAPER F ED SOUND ALARMS ATIVE DELAYS J-NET RS 485 INT. RS485 INTERFAE J1&J2OFF J1&J2ON (OPTIONAL) Only used, if there are externally connected Sub-Panels or Repeaters (EN-54) INSTALLATION & OMMISSIONING MANUAL REVISION 1.1 OT 4,

15 SILENE A ON 272 4R7 35 FAULT FIRE SILENE A ON 272 4R7 35 FAULT FIRE ON MON 272 4R7 35 OMMS OK OMMS FLT FAULT PRE-ALARM FIRE 5VOLTFAULT MEANWELL GLOBAL Identifying omponents Panel box for Sub-Panels OVERVIEW Inside a Sub-Panel Box ETH LOOP 1 LOOP 1 LOOP 2 LOOP 2 LOOP 3 LOOP 3 SNDR 1 SNDR 2 ETH LOOP 1 LOOP 1 LOOP 2 LOOP 2 LOOP 3 LOOP 3 SNDR 1 SNDR 2 N3 N4 MPX N5 1A F U S E FASE NEUTRO ETH LOOP 1 LOOP 1 LOOP 2 LOOP 2 LOOP 3 LOOP 3 SNDR 1 SNDR 2 H8/3003 SUB-PANEL 3 N3 N4 MAX 3A FAST ATING MPX N5 OMMSOK OMMSFLT PRE-ALARM 5 VOLT FAULT EVA PANEL NO H8/3003 SUB-PANEL 2 N3 N4 MAX 3A FAST ATING MPX N5 OMMSOK OMMSFLT PRE-ALARM 5 VOLT FAULT EVA BATT 24V SILENE A PANEL NO SUB-PANEL 1 H8/3003 J-NET-SP with LOOP-ARD 0V 24V 0V 0V 28V 28V AUX PS POWER SUPPLY IN MAX 3A FAST ATING BATT EVA 24V MODEL: LPP-1-27 INPUT: VA ; VD 47/63Hz PUT: +27V 5.6A DANGER 220 VOLTS 5A POWER SUPPLY UNIT PANEL NO MON 0V 24V 0V 0V 28V 28V AUX PS POWER SUPPLY IN BATT 24V MON 0V 24V 0V 0V 28V 28V AUX PS POWER SUPPLY IN J-NET-SP with LOOP-ARD J-NET-SP with LOOP-ARD J-NET-RS485-INT-NEW RS 485 RS 485 IN TX 1 RX 2 RX 1 TX 2 A B A B A B A B J1 J2 J-NET RS 485 INT. MAIN PANEL J1&J2OFF SUB PANEL or REPEATERS J1&J2ON (EN-54) INSTALLATION & OMMISSIONING MANUAL REVISION 1.1 OT 4,

16 LK 2 LK 1 GLOBAL OVERVIEW Identifying omponents FIB.OPT. / RS-485 ON 1 INT. SUB PANEL ON 5 TX RX LOADER ON 6 FIRE BRIG. AKNOWL. MAX 3A FAST ATING FLT FIR PAL N NO N NO N REPEATS FAULT AUX 2 AUX 1 ON 2 ZONE LED AUX 1 PSU 0v 24v 0v PF E SF AUX 2 PSU ZONE MPX BELL 1 BELL 2 0v EVA 24v BATT ON 7 J-NET-ON: -ONNETOR BOARD RS 485 RS 485 IN TX 1 RX 2 RX 1 TX 2 A B A B A B A B LOOP 1 LOOP 1 LOOP 2 LOOP 2 LOOP 3 LOOP 3 J1 J2 J-NET RS 485 INT. MAIN PANEL J1&J2OFF SUB PANEL or REPEATERS J1&J2ON J-NET-LPON: ANALOGUE LOOP ONNETOR J-NET-INT-485 JUNO NET INTERFAE FOR RS485 OMMUNIATION STF1 MAX 485 MAX 485 RX TX STF3 STF4 STF2 TX J-NET-INT-FO: FIBRE OPTI INTERFAE RX J-NET- ADV-OMS : OMMUNIATION INTERFAE 3 TYPES AVAILABLE: RS232/485 - FIBRE OPTI - TP/IP (EN-54) INSTALLATION & OMMISSIONING MANUAL REVISION 1.1 OT 4,

17 OVERVIEW LOOP 3 LOOP 3 LOOP 2 LOOP 2 N4 SNDR 1 SNDR 2 N3 MPX N5 OMMS OK LOOP 1 OMMS FLT 0V 24V 0V 0V 28V 28V MON AUX PS POWER SUPPLY IN LOOP 1 ETH FAULT PRE-ALARM FIRE 5VOLTFAULT MAX 3A FAST ATING EVA BATT 24V H8/3003 SILENE PANEL NO A ON J-NET-SP: SUB-PANEL BOARD 272 4R L or 3-L 1 LOOP ARD or 3 LOOP ARD (EN-54) INSTALLATION & OMMISSIONING MANUAL REVISION 1.1 OT 4,

18 OVERVIEW MOTHERBOARD (BAK VIEW) QUAD UART J-NET-QUART: QUAD UART SIM ARD ONNETOR LOOPARD HEADER DISPLAY STANDOFFS (4) FOR LOOPARD LOOPARD HEADER WAY BOX HEADER FOR J-NET-ON LOOPARD HEADER MASTER RESET PRINTER ONNETOR 16 WAY BOX HEADER FOR LOOP ONNETOR PS2 P KEYBOARD ADAPTOR PRINTER FUSE 1A J-NET-SIM: SIM ARD Typical cable form (one end) VIEW FROM FRONT NOTE: THROUGH THE MANUAL, THE RED PIN ON THE 5 WAY MOLEX INDIATES WHIH PIN IS N1 º VIEW FROM TOP MALE FEMALE (EN-54) INSTALLATION & OMMISSIONING MANUAL REVISION 1.1 OT 4,

19 Recommended ables OVERVIEW Analogue Loops, onventional Sounders and Data Loops The can be installed as either a self-contained or a distributed system. The self contained system does not require external data loop connections. The distributed system requires a 4-core data loop cable for connection to remote sub-panels and Repeaters. The data loop connects the Main Panel to the first Sub-panel and then to the second Sub-panel, etc., and eventually returns to the Main Panel. Fire rated ables for Loops and Sounder ircuits 2 2 AEI type Firetec Multicore Ref. F11 (1 mm ) to F12.5 (2.5 mm ) in 2 core 2 2 AEI type Firetec Armoured Ref. F21 (1.5 mm ) to F22.5 (2.5 mm ) in 2 core 2 AEI type Mineral Insulated able (all types up to 2.5 mm BI types Mineral Insulated twin twisted conductor cables, Ref. M2T1RG and M2T1.5 RG 2 BI types Mineral Insulated Pyrotenax (all types up to 2.5 mm ) 2 ALFLEX type alflam WZ 2 core type up to 2.5 mm 2 2 PIRELLI type FP200 Gold 2 core type from 1 mm to 2.5 mm 2 FIRETUF (OHLS) FTZ up to 2.5 mm. Manufactured by Draka All cables should be screened. Minimum detection loop conductor section size is 0.5 sq.mm Maximum detection loop conductor section size is 2.5 sq.mm There should only be one analogue detector loop per shielded cable. Analogue detector loops and conventional sounders should not run in the same shielded cable. If the system requires one or more repeaters, it will be necessary to use a four core data cable to create a data loop between the panel and the repeater. Alternatively, it is possible to use multi-mode dual-core fibre-optic cable or a TP/IP connection for the same purpose. Data loop cable should be RS422/485 grade data cable, eg: Signal cables for RS485 ommunication Links (twisted pair) to Repeater panels 12 AWG Signal Belden 9583 WPW AWG Signal Belden 9581 WPW AWG Signal Belden 9575 WPW AWG Signal Belden 9574 WPW975 FIRETUF FDZ0 by Draka 2 core PIRELLI type FP200 Gold 2 core PIRELLI type FP-PLUS Fibre Optic: connectors Multi.mode Dual ore sheathed fire proff with 62,5µ/125µ fibre terminated in ST Limitations A fire alarm system can provide early warning of a developing fire but it does not assure protection against damage or loss resulting from a fire. The fire alarm system should be designed and installed in accordance with all relevant regulations and codes of practice. To ensure maximum protection the system should be regularly tested and inspected by qualified fire alarm installation personnel. Inspection and testing should be carried out in accordance with the appropriate local standards. (EN-54) INSTALLATION & OMMISSIONING MANUAL REVISION 1.1 OT 4,

20 Definitions Analogue Loop OVERVIEW The physical link, usually fireproof 2 conductor shielded wiring cable, forming a ring of interconnection between sensors and the detection panel. able form A connecting lead. Typically a length of flat cable with connectors at both ends. onventional Sounder A onventional Sounder is an audible output device that is connected to the onventional Sounder outputs on a Main Panel or Sub-panel. It is different electrically to a Loop powered Sounder. Data Loop This may take the form of RS485 or a fibre optic link. It provides communications between the Main Panel and Repeaters or Sub-panels. Detector Any type of fire sensor (heat, smoke) that is connected to an Analogue Loop. Device A detector, sounder, interface module or call-point connected to an Analogue Loop. Evacuate A system state where all sounders are activated simultaneously. Pressing SOUND ALARMS will generate an evacuate condition. Fibre Optic Link A connection method for data that uses light instead of electrical signals. The connection is made using fibre optic cables rather than copper electrical cables. Fibre optic signals can travel far greater distances than electrical signals with less risk of electromagnetic interference. Flash Non-volatile memory inside the panel used to store the program and the customer site data. Flash data storage is very robust and needs no power at all to retain the data. Integrated Sub-panel (ISP) A Main Panel or Repeater can have an Integrated Sub-panel. This is a single sub-panel that can support one or three Analogue Loops. (EN-54) INSTALLATION & OMMISSIONING MANUAL REVISION 1.1 OT 4,

21 Local Sounder OVERVIEW A local conventional sounder is an audible output device (bell or sounder) that is connected to the local bell output on a main or sub panel. Loop Sounder The term Loop Sounder is used to describe an audible output device that is connected to and controlled individually by an Analogue Loop. Loop Sounders are different electrically from onventional Sounders. Main Panel An installation only has one, and one only, Main Panel. This is the heart of the system, which monitors and controls all the components in the system, although not always directly. NVRAM Non-volatile Random Access Memory. Any information stored in this memory will not be cleared when power is removed from the system. The system has an internal battery for the NVRAM. PB Printed ircuit Board. Repeater A Repeater is a remote terminal to the Main Panel. Everything that is displayed on the Main Panel is also displayed on the Repeater. Any LEDs illuminated on the Main Panel are illuminated on the Repeater. Key presses and programming input at the Repeater are sent directly to the Main Panel, as if the input were actually occurring at the Main Panel. SIM ARD Single In-line Memory ard. Fitted to the SIM ARD is the Flash memory that contains the Main Panel software and the system settings (ustomer Flash Memory ). Sub-panel These provide the Analogue Loops. Each Sub-panel supports one or three Analogue Loops. There are two types of Sub-panels: Integrated and Standard. An integrated sub-panel consists of a loop card installed onto either the Main panel or Repeater Motherboard. A standard Sub-panel consists of a loop card installed on a Sub-panel board which is a basic fire control panel with its own PU, local memory and fire signaling outputs. The Sub-panel reports all events to the main panel but can operate individually in the event of communication loss. Up to 3 standard Sub-panels can be housed within a Main Panel box. Additional Standard Sub-panels can be housed externally, and typically, will be distributed around the building. Sub-panels are connected to the Main Panel via the Data Loop. The System The Main Panel, Sub-panels, Repeaters, and all devices. Zone A situational group of devices. A Zone can consist of a collection of any of the devices connected to the system. (EN-54) INSTALLATION & OMMISSIONING MANUAL REVISION 1.1 OT 4,

22 Introduction INSTALLATION This section covers the physical installation of the system. It primarily focuses on the parts that are required and how they should be connected together. Do not connect the mains power or the batteries at this stage; commissioning the system is covered in the next section of this manual. Installation should always be performed in accordance with a system plan. Main Panel The control panel should be located where access to the internal components is not restricted and where the unit is not exposed to high levels of moisture, vibration and shock. Avoid placing the panel in direct sunlight as this may impair programming using the infra-red keypad. Any metal swarf could damage the PBs if it is still present when the panel is powered up so it is recommended that all PBs are removed from the main box whilst the box is being installed. Make a note of the positions of the PBs before removal. ELETRO-STATI SENSITIVE DEVIES (ESD) TAKE SUITABLE ESD PREAUTION WHEN REMOVING OR INSTALLING PRINTED IRUIT BOARDS. Warning - observe ESD precautions when handling the PBs. Mains Power onnection The panel must be earthed. The LIVE connection must be made to the fused input on the power supply module. This input will also have a BLAK or BROWN wire leading into the power supply unit. The connector with a BLUE wire leading into the power supply unit is the NEUTRAL. Other Main Panel connections These are detailed in the relevant following sections. Most connections are made from the J-NET- ON. Integrated Sub-panels A Main Panel may have an Integrated Sub-panel. To enable the Integrated Sub-panel a Loopcard must be fitted to the Main Panel PB. The Loopcard is secured on to 4 pillars behind the LD module. You may fit a 1 or 3 loop Loopcard. If the Loopcard is fitted, an ANALOGUE LOOP ONNETION BOARD is also required. This is mounted inside the Main Panel box and requires a cable form between it and the Main Panel PB. Ensure all connectors are correctly aligned. (EN-54) INSTALLATION & OMMISSIONING MANUAL REVISION 1.1 OT 4,

23 INSTALLATION J-NET-ON N O FIB.OPT. / RS-485 ON 1 INT. SUB PANEL TX RX ON 5 P LOADER ON 6 FIRE BRIG. AKNOWL. MAX 3A FAST ATING FLT FIR PAL N NO N NO N REPEATS FAULT AUX 2 AUX 1 M L K J ON 2 ZONE LED Q AUX 1 PSU 0v 24v 0v PF E SF AUX 2 ZONE 0v PSU MPX BELL 1 BELL 2 EVA 24v BATT ON 7 A B D E F G H A B D E F G H I J K L M N O P Q Auxiliary power supply output for powering external devices. Auxiliary power supply output for powering external devices. Both auxiliary power supply outputs are individually power limited and supervised. Max. urrent Rating/ Output is 230 ma b@ 27.5 V D nominal. Zone multiplex output for zone or mimic panel. onventional Sounder ircuit 1. onventional Sounder ircuit 2. Each onventional Sounder ircuit is current limited and monitored for both open and short circuit fault conditions. The use in each circuit of a 10 K ohms E.O.L. resistor is required. Max. urrent Rating/ Output is V D nominal. WARNING: The total current load of all detection loops, sounder circuits and auxiliary supply outputs should not exceed the maximum power rating of the panel. Please refer to technical specification tables. Remote Evacuation / lass hange Input. (onventional sounder outputs only) System Power Input (pre-wired and monitored). Battery onnection Earth Point. Auxiliary Fault Relay Output. (Activated by any fault present on the system) This relay output will remain closed while there are no faults present in the system. Under any fault condition present, the relay will be de-energised and the relay contact will be open. Auxiliary Fire Relay Output 2. (Activated by any fire situation present Auxiliary Fire Relay Output 1. on the system, disabled by front button) Under the presence of any Fire Alarm condition, these 2 relays will be energised. Both set of contacts are of the change-over type. Max. ontact current rating for each set of relay contacts is 1 V A/D resistive. WARNING: Relay outputs are not supervised. Please ensure that any wiring connected to these outputs is power limited. Pre-alarm, Fault and Fire, Open ollector Outputs. Loader Interface: For Upload/Download Software ON 1: Used to connect to other sub-panels within a self-contained panel ON 5: Used for connecting RS485, Fibre-Optic, and TP/IP ON 2: Used for MPX, Zone LEDs (EN-54) INSTALLATION & OMMISSIONING MANUAL REVISION 1.1 OT 4,

24 Repeaters INSTALLATION Repeaters are installed in a similar manner to the Main Panel. Mini Rep repeaters are supplied by an external 24Vdc, normally from the control panel. The Repeater should be located where access to the internal components is not restricted and where the unit is not exposed to high levels of moisture, vibration and shock. Avoid placing the Repeater in direct sunlight as this may impair programming using the infra-red keypad. Any metal swarf could damage the PBs if it is still present when the Repeater is powered up so it is recommended that all PBs are removed from the box whilst the box is being installed. Make a note of the positions of the PBs before removal. ELETRO-STATI SENSITIVE DEVIES (ESD) TAKE SUITABLE ESD PREAUTION WHEN REMOVING OR INSTALLING PRINTED IRUIT BOARDS. Warning - observe ESD precautions when handling the PBs. Mains Power onnection The Repeater must be earthed. The LIVE connection must be made to the fused input on the power supply module. This input will also have a BLAK or BROWN wire leading into the power supply unit. The connector with a BLUE wire leading into the power supply unit is the NEUTRAL. Integrated Sub-panels A Repeater may have an Integrated Sub-panel. To enable the Integrated Sub-panel a Loopcard must be fitted to the Repeater PB. The Loopcard is secured on to 4 pillars behind the LD module. You may fit a 1 or 3 loop Loopcard. If the Loopcard is fitted an ANALOGUE LOOP ONNETION BOARD is also required. This is mounted inside the Repeater box and requires a cable form between it and the Repeater PB. Ensure all connectors are correctly aligned. (EN-54) INSTALLATION & OMMISSIONING MANUAL REVISION 1.1 OT 4,

25 Standard Sub-panels INSTALLATION Standard Sub-panels need 28.5V D to operate. This should be supplied from the Power Supply Unit found inside the box. Standard Sub-panels need a Loopcard fitted to operate. This fits on top of the sub-panel and almost completely covers it. This is usually supplied fitted but if not ensure that all connectors are correctly aligned before fitting the 4 retaining screws. A B SNDR 1 SNDR 2 ETH LOOP 1 LOOP 1 LOOP 2 LOOP 2 LOOP 3 LOOP 3 N3 N4 A onventional Sounder Outputs MPX N5 B Earth onnection Analogue Loop onnections J-NET-SP D Local status LEDs E 3 amp fuse F Evacuation Input (conventional sounder circuits only) K J SILENE A PANEL NO ON H8/3003 MAX 3A FAST ATING OMMS OK OMMS FLT FAULT PRE-ALARM FIRE 5VOLTFAULT EVA BATT 24V D E F G G H I J K Battery onnection (24V D nominal) Power Supply In (28.5V D max) 24V Auxiliary Supply Output Emergency Silence/RAM initialize Address Switch (DIP) 0V 24V MON 0V 0V 28V 28V AUX PS POWER SUPPLY IN I H NOTE: To monitor an external power supply, a third wire should be connected between the MON and the 0V on the external power supply s 0V connection. If the power supply is installed in the same cabinet as the sub-panel, a link must be fitted between MON and 0V at the power supply IN connection terminals. (EN-54) INSTALLATION & OMMISSIONING MANUAL REVISION 1.1 OT 4,

26 INSTALLATION Data Loops If the system is distributed, the communication between the main panel and the external sub-panels or repeaters is supported by either an RS422/485 fully redundant loop, fibre-optic cable or alternatively by TP/IP. For redundancy in the case of RS422/485 and Fibre Optic this can be wired in the form of a Loop, thus protecting the Data Loop from interruptions or short circuits by creating a bi-directional communications flow. If the panel loses communications with the repeater it will try via the opposite path. RS422/485 may be used for distances of up to 1200m. For longer distances (up to 4,5km) Fibre Optic Data connections should be used. TOPOLOGIES MAIN PANEL SUB PANEL REPEATER REPEATER & SUB PANEL RS485, FIBRE OPTI or TP/IP MAIN SUB SUB RS485 SIMULTANEOUS SUB SUB RS485, FIBRE OPTI or TP/IP INTERFAE SUB FIBRE OPTI SUB DIRET TTL BUS 12 LOOPS IN ONE BOX DIRET TTL ONNETION BETWEEN UP TO THREE SUB-PANELS (EN54) INSTALLATION & OMMISSIONING MANUAL - REVISION OT 4,

27 Main Panel RS485 INSTALLATION Note - Make all connections with the power turned off to avoid risk of permanent damage to the circuit boards. If an external data loop is required, the main panel will need an RS485, a FIBRE OPTI or a TP/IP INTERFAE BOARD fitted to the main panel onnector Board. J-NET-ON FIB.OPT. / RS-485 ON 1 INT. SUB PANEL ON 5 TX RX LOADER ON 6 FIRE BRIG. AKNOWL. MAX 3A FAST ATING FLT FIR PAL N NO N NO N REPEATS FAULT AUX 2 AUX 1 ON 2 ZONE LED AUX 1 PSU 0v 24v 0v PF E SF AUX 2 PSU ZONE MPX BELL 1 BELL 2 0v EVA 24v BATT ON 7 N3 RS 485 RS 485 IN TX 1 RX 2 RX 1 TX 2 A B A B A B A B J-NET-RS485-INT-NEW-NEW J2 J1 J-NET RS 485 INT. MAIN PANEL J1&J2OFF SUB PANEL or REPEATERS J1&J2ON (EN54) INSTALLATION & OMMISSIONING MANUAL - REVISION OT 4,

28 LK 2 LK 1 GLOBAL INSTALLATION Data Loop Interface onfiguration N3 RS 485 RS 485 IN TX 1 RX 2 RX 1 TX 2 A B A B A B A B J1 J-NET-RS485-INT-NEW J2 J-NET RS 485 INT. MAIN PANEL = LINKS J1&J2 OFF MAIN PANEL J1&J2OFF SUB PANEL or REPEATERS J1&J2ON REPEATER / SUB-PANEL= ON If these interfaces are to be used at the Main Panel, all links on both the RS485 INTERFAE BOARD (J1 & J2) and FIBRE-OPTI INTERFAE BOARD (LK1 & LK2) should be removed. When used on Repeaters or Sub-panels they should be kept linked. STF4 RX TX TX RX STF1 STF3 MAIN PANEL = REPEATER / SUB-PANEL= LINKS OFF ON STF2 J-NET-INT-FO (EN54) INSTALLATION & OMMISSIONING MANUAL - REVISION OT 4,

29 INSTALLATION Repeater RS485 Note - Make all connections with the power turned off to avoid risk of permanent damage to the circuit boards. The Repeater will need an RS485, a FIBRE OPTI or a TP/IP INTERFAE BOARD fitted to its onnector Board. J-NET-ON FIB.OPT. / RS-485 ON 1 INT. SUB PANEL ON 5 TX RX LOADER ON 6 FIRE BRIG. AKNOWL. MAX 3A FAST ATING FLT FIR PAL N NO N NO N REPEATS FAULT AUX 2 AUX 1 ON 2 ZONE LED AUX 1 PSU 0v 24v 0v PF E SF AUX 2 PSU ZONE MPX BELL 1 BELL 2 0v EVA 24v BATT ON 7 N3 RS 485 RS 485 IN TX 1 RX 2 RX 1 TX 2 A B A B A B A B J-NET-RS485-INT-NEW J2 J1 J-NET RS 485 INT. MAIN PANEL J1&J2OFF SUB PANEL or REPEATERS J1&J2ON (EN54) INSTALLATION & OMMISSIONING MANUAL - REVISION OT 4,

30 Standard Sub-panel RS485 INSTALLATION If more than one Sub-panel is mounted within a single enclosure, only one RS485 INTERFAE BOARD or FIBRE-OPTI INTERFAE BOARD needs to be used. The Standard Sub-panels will be interconnected via a TTL bus using a cable form in a daisy-chain from N4 in the first Sub-panel to N3 in the next and on to N3 on the RS485 INTERFAE BOARD or ON1 on the FIBRE-OPTI INTERFAE BOARD. SNDR 1 SNDR 2 LOOP 3 LOOP 2 LOOP 1 LOOP 3 LOOP 2 N4 0V 24V 0V 0V 28V 28V MON AUX PS POWER SUPPLY IN LOOP 1 ETH N3 MPX N5 OMMS OK OMMS FLT FAULT PRE-ALARM FIRE 5VOLTFAULT MAX 3A FAST ATING EVA BATT 24V H8/ J-NET-SP ON SILENE PANEL NO A N3 RS 485 RS 485 IN TX 1 RX 2 RX 1 TX 2 A B A B A B A B J1 J-NET-RS485-INT-NEW J2 J-NET RS 485 INT. MAIN PANEL J1&J2OFF SUB PANEL or REPEATERS J1&J2ON (EN54) INSTALLATION & OMMISSIONING MANUAL - REVISION OT 4,

31 INSTALLATION RS485 External onnection The 4 wire external RS485 connections should be made as below: Main Panel LOOP TX1 A TX1 B RX2 A RX2 B First Sub-panel or Repeater LOOP IN RX1 A RX1 B TX2 A TX2 B Then continue to connect of one Repeater/Sub-panel to IN of the next Repeater/Sub-Panel following the same connection rules as above. When you reach the last Repeater/Sub-panel in the loop make the connections as follows: Main Panel LOOP IN RX1 A RX1 B TX2 A TX2 B Last Sub-panel or Repeater LOOP TX1 A TX1 B RX2 A RX2 B N3 RS 485 RS 485 IN TX 1 RX 2 RX 1 TX 2 A B A B A B A B J1 J-NET-RS485-INT-NEW J2 J-NET RS 485 INT. MAIN PANEL J1&J2OFF SUB PANEL or REPEATERS J1&J2ON (EN54) INSTALLATION & OMMISSIONING MANUAL - REVISION OT 4,

32 AUX 1 ON ON ON GLOBAL INSTALLATION onnection Schematic for Self-ontained Panels J-NET-ON J-NET-SP with LOOP-ARD FIB.OPT. / RS-485 ON 1 INT. SUB PANEL ON 5 TX RX LOADER ON 6 FIRE BRIG. AKNOWL. MAX 3A FAST ATING FLT FIR PAL N NO N NO N REPEATS FAULT AUX 2 AUX 1 LOOP 1 LOOP 1 LOOP 2 LOOP 2 LOOP 3 LOOP 3 N4 N R7 35 MPX N5 OMMS OK OMMS FLT FAULT PRE-ALARM FIRE 5VOLTFAULT H8/3003 MAX 3A FAST ATING EVA BATT 24V 0V 0V 0V 24V 28V 28V MON AUX PS POWER SUPPLY IN ON 2 ZONE LED PSU 0v 24v 0v PF E SF AUX 2 ZONE 0v PSU MPX BELL 1 BELL 2 EVA 24v BATT ON 7 ETH SNDR 1 SNDR 2 LOOPS4TO LOOP 1 SILENE PANEL NO A LOOP 1 J-NET-LPON LOOP 2 LOOP 2 LOOP 3 LOOP 3 LOOPS1TO3 In a self-contained panel of up to 12 loops, there is no requirement for an RS485 Interface Board because the Sub-Panels can be inter-connected via a TTL bus. The connections are made as follows: ETH LOOP 1 LOOP 1 LOOP 2 LOOP 2 LOOP 3 LOOP 3 SNDR 1 SNDR 2 N4 N R7 35 MPX N5 J-NET-SP with LOOP-ARD OMMS OK OMMS FLT LOOPS7TO9 FAULT PRE-ALARM FIRE 5VOLTFAULT H8/3003 MAX 3A FAST ATING EVA BATT 24V SILENE PANEL NO A 0V 0V 0V 24V 28V 28V MON AUX PS POWER SUPPLY IN ON1 N3 N3 (J-NET-ON) (1st SUB-PANEL) (2nd SUB-PANEL) to N4 to N4 to N4 (1st SUB-PANEL) (2nd SUB-PANEL) (3rd SUB-PANEL) NOTE: There is no need to terminate the last sub-panels N3 because the bus connection is a parallel one. ETH LOOP 1 LOOP 1 LOOP 2 LOOP 2 LOOP 3 LOOP 3 SNDR 1 SNDR 2 N4 N R7 35 MPX N5 OMMS OK OMMS FLT FAULT PRE-ALARM FIRE 5VOLTFAULT H8/3003 EVA BATT 24V 0V 0V 0V 24V 28V 28V MON AUX PS POWER SUPPLY IN SILENE PANEL NO A J-NET-SP with LOOP-ARD MAX 3A FAST ATING LOOPS 10 TO 12 (EN54) INSTALLATION & OMMISSIONING MANUAL - REVISION OT 4,

33 SILENE A ON MON 272 4R7 35 FAULT PRE-ALARM FIRE ON MON 272 4R7 35 FAULT PRE-ALARM FIRE FIRE FIRE ON ON 2 ZONE LED INT. SUB PANEL ON 5 SNDR 1 SNDR 2 TX RX AUX 1 PSU ETH J2 J1 LOOP 1 LOOP 1 LOOP 2 ON 6 FIRE BRIG. AKNOWL. 0v 24v 0v PF E SF AUX 2 ZONE 0v PSU MPX BELL 1 BELL 2 EVA AUX PS RS 485 RS 485 IN TX 1 RX 2 RX 1 TX 2 A B A B A B A B J2 LOOP 2 0V 24V MON 0V 0V J1 LOOP R V 28V POWER SUPPLY IN MAX 3A FAST ATING LOOP 3 N3 N4 A 24v BATT OMMS OK OMMS FLT FAULT PRE-ALARM FIRE 5VOLTFAULT B A B FLT FIR PAL N NO N NO N ON 7 MAIN PANEL SUB PANEL or REPEATERS A B A B MEANWELL 1A F U S E 220 VOLTS MEANWELL GLOBAL INSTALLATION onnection Schematic: Main Panel to External Sub-Panel(s) J-NET-ON FAULT PRE-ALARM FIRE ALARM SYSTEM FAULT FIB.OPT. / RS-485 ON 1 LOADER FASE NEUTRO TEST DISABLED SYSTEM ON ALARM DISPLAY QUEUE REVIEW TEST J-NET-LPON LOOP 1 LOOP 1 LOOP 2 LOOP 2 MODEL: LPP-1-27 INPUT: VA ; VD 47/63Hz PUT: +27V 5.6A ALARM FAULT SU PLY FAULT PRO. FAULT TRANS. FAULT JUNONET MANUFATURED TO THE REQUIREMENTS OF EN54 PT FIRE BRIGADE AKNOWLEDGED ALARM SILENE SYSTEM RESET LAMP TEST AUXILIARY RELAYS FIRE BRIGADE TRANSMI SION SELETED DETETORS DISABLED LOOP 3 LOOP 3 J-NET-RS485-INT-NEW DANGER 5A POWER SUPPLY UNIT PAPER F ED SOUND ALARMS ATIVE DELAYS J-NET RS 485 INT. RS485 INTERFAE J1&J2OFF J1&J2ON (OPTIONAL) Only used, if there are externally connected Sub-Panels SEE NEXT PAGE J-NET-SP with LOOP-ARD 1A ETH LOOP1 LOOP1 LOOP2 LOOP2 LOOP3 LOOP3 SNDR1 SNDR 2 H8/3003 OMMSOK OMMSFLT 5 VOLT FAULT SILENE A PANEL NO SUB-PANEL 1 H8/3003 MPX N5 EVA BATT 24V F U S E FASE NEUTRO MODEL: LPP-1-27 INPUT: VA ; VD 47/63Hz PUT: +27V 5.6A DANGER 220 VOLTS 5A POWER SUPPLY UNIT SUB-PANEL 3 N3 N4 MPX N5 EVA BATT 24V ETH LOOP1 LOOP1 LOOP2 LOOP2 LOOP3 LOOP3 SNDR1 SNDR2 J-NET-SP with LOOP-ARD J-NET-SP with LOOP-ARD MAX 3A FAST ATING H8/3003 PANEL NO N3 N4 MPX N5 OMMSOK OMMSFLT 5 VOLT FAULT EVA SILENE BATT 24V REPEATS FAULT AUX 2 AUX 1 PANEL NO A SUB-PANEL 2 MAX 3A FAST ATING MAX 3A FAST ATING 0V 24V 0V 0V 28V 28V AUX PS POWER SUPPLY IN 0V 24V 0V 0V 28V 28V AUX PS POWER SUPPLY IN RS 485 RS 485 IN TX 1 RX 2 RX 1 TX 2 J-NET RS 485 INT. MAIN PANEL J1&J2OFF SUB PANEL or REPEATERS J1&J2ON J-NET-RS485-INT-NEW (EN54) INSTALLATION & OMMISSIONING MANUAL - REVISION OT 4,

34 AUX R7 35 GLOBAL INSTALLATION onnection Schematic: Main Panel to External Sub-Panel(s)via RS485 MAINPANEL RS485 EXT. SUB-PANEL J-NET-ON FIB.OPT. / RS-485 ON 1 INT. SUB PANEL TX RX ON 5 LOADER ON 6 FIRE BRIG. AKNOWL. MAX 3A FAST ATING FLT FIR PAL N NO N NO N REPEATS FAULT AUX 2 AUX 1 J-NET-SP with LOOP-ARD ETH LOOP 1 SNDR 1 SNDR 2 LOOP 1 LOOP 2 LOOP 2 LOOP 3 LOOP 3 N3 N4 MPX N5 ON 2 ZONE LED PSU 0v 24v 0v PF E SF AUX 2 ZONE 0v PSU MPX BELL 1 BELL 2 EVA 24v BATT ON 7 LOOP 3 LOOP 2 LOOP 2 LOOP 1 LOOP 1 H8/3003 OMMS OK OMMS FLT FAULT PRE-ALARM FIRE 5VOLTFAULT MAX 3A FAST ATING LOOP 3 J-NET-LPON SILENE A PANEL NO ON EVA BATT 24V 0V 24V MON 0V 0V 28V 28V AUX PS POWER SUPPLY IN N3 RS 485 RS 485 IN TX 1 RX 2 RX 1 TX 2 A B A B A B A B N3 RS 485 RS 485 IN TX 1 RX 2 RX 1 TX 2 A B A B A B A B J1 J1 J2 J-NET RS 485 INT. MAIN PANEL J1&J2OFF SUB PANEL or REPEATERS J1&J2ON J2 J-NET RS 485 INT. MAIN PANEL J1&J2OFF SUB PANEL or REPEATERS J1&J2ON J-NET-RS485-INT-NEW J-NET-RS485-INT-NEW REMEMBER TO ONFIGURE JUMPERS!! REMEMBER TO ONFIGURE JUMPERS!! MAIN PANEL EXTERNAL SUB- PANEL ON 5 J-NET-ON ON 3 RS485 INTERFAE ON3or4 SUB-PANEL ON 3 RS485 INTERFAE PIN#1 PIN#2 PIN#3 PIN#4 PIN#5 PIN#1 PIN#2 PIN#3 PIN#4 PIN#5 PIN#1 PIN#2 PIN#3 PIN#4 PIN#5 PIN#1 PIN#2 PIN#3 PIN#4 PIN#5 (EN54) INSTALLATION & OMMISSIONING MANUAL - REVISION OT 4, 2005 ON 3 AND 4 ARE IN PARALLEL ONNETIONS AN BE MADE TO EITHER ONE 33

35 ON AUX 1 OMMS OK OMMS FLT FAULT PRE-ALARM FIRE 5VOLTFAULT GLOBAL MAINPANEL INSTALLATION FIBRE-OPTI EXT. SUB-PANEL STF1 STF3 STF1 STF3 FIB.OPT. / RS-485 ON 1 INT. SUB PANEL TX RX ON1 ON 5 TX J-NET-INT-FO RX LOADER LK 2 STF4 LK 1 TX RX STF2 ON 6 FIRE BRIG. AKNOWL. MAX 3A FAST ATING FLT FIR PAL N NO N NO N REPEATS J-NET-SP SNDR 1 SNDR 2 ETH LOOP 1 LOOP 1 LOOP 2 LOOP 2 LOOP 3 LOOP 3 N3 N4 MPX N5 ON1 TX RX LK 2 STF4 LK 1 TX RX J-NET-INT-FO STF2 AUX 1 PSU 0v 24v 0v PF E SF AUX 2 ZONE 0v PSU MPX BELL 1 BELL 2 EVA 24v BATT J-NET-ON LOOP 3 LOOP 3 LOOP 2 LOOP 2 LOOP 1 LOOP 1 MAX 3A FAST ATING H8/3003 MAIN PANEL MAINPANEL FIBRE-OPTI STANDARD SUB- PANEL REPEATER FIB.OPT. / RS-485 ON 1 STF1 INT. SUB PANEL TX RX LOADER LK 2 ON 5 STF4 STF3 LK 1 ON 6 FIRE BRIG. AKNOWL. MAX 3A FAST ATING STF2 ON 2 ZONE LED 0v 24v 0v PF E SF AUX 1 AUX 2 ZONE 0v 24v PSU PSU MPX BELL 1 BELL 2 EVA BATT FLT FIR PAL N NO N NO N ON 7 REPEATS FAULT AUX 2 AUX 1 FIB.OPT. / RS-485 ON 1 INT. SUB PANEL TX RX ON 5 ON 2 ZONE LED PSU LOADER ON 6 FIRE BRIG. AKNOWL. MAX 3A FAST ATING STF2 0v 24v 0v PF E SF AUX 2 ZONE 0v 24v PSU MPX BELL 1 BELL 2 EVA BATT FLT FIR PAL N NO N NO N ON 7 REPEATS FAULT AUX 2 AUX 1 LOOP 3 LOOP 3 LOOP 3 LOOP 3 LOOP 2 LOOP 2 LOOP 2 LOOP 2 LOOP 1 LOOP 1 LOOP 1 LOOP 1 PANEL N O SILENE A BATT 24V EVA FAULT AUX 2 AUX 1 ON 2 ZONE LED ON 7 J-NET-LPON 0V 24V MON 0V 0V 28V 28V AUX PS POWER SUPPLY IN ON1 TX RX TX RX J-NET-INT-FO STF1 TX RX STF3 LK 1 LK 2 STF4 TX RX J-NET-ON J-NET-ON J-NET-LPON J-NET-LPON MAIN PANEL (EN54) INSTALLATION & OMMISSIONING MANUAL - REVISION OT 4, 2005 REPEATER PANEL 34

36 AUX 1 GLOBAL INSTALLATION onnection Schematic: Main Panel to Repeater Panel(s)via RS485 MAINPANEL RS485 REPEATER J-NET-ON J-NET-ON FIB.OPT. / RS-485 ON 1 INT. SUB PANEL TX RX ON 5 LOADER ON 6 FIRE BRIG. AKNOWL. MAX 3A FAST ATING FLT FIR PAL N NO N NO N REPEATS FAULT AUX 2 AUX 1 FIB.OPT. / RS-485 ON 1 INT. SUB PANEL TX RX ON 5 LOADER ON 6 FIRE BRIG. AKNOWL. MAX 3A FAST ATING FLT FIR PAL N NO N NO N REPEATS FAULT AUX 2 AUX 1 ON 2 ZONE LED PSU 0v 24v 0v PF E SF AUX 2 ZONE 0v PSU MPX BELL 1 BELL 2 EVA 24v BATT ON 7 ON 2 ZONE LED AUX 1 PSU 0v 24v 0v PF E SF AUX 2 ZONE 0v PSU MPX BELL 1 BELL 2 EVA 24v BATT ON 7 LOOP 3 LOOP 3 LOOP 3 LOOP 3 LOOP 2 LOOP 2 LOOP 2 LOOP 2 LOOP 1 LOOP 1 LOOP 1 LOOP 1 J-NET-LPON J-NET-LPON N3 RS 485 RS 485 IN TX 1 RX 2 RX 1 TX 2 A B A B A B A B N3 RS 485 RS 485 IN TX 1 RX 2 RX 1 TX 2 A B A B A B A B J1 J1 J2 J-NET RS 485 INT. MAIN PANEL J1&J2OFF SUB PANEL or REPEATERS J1&J2ON J2 J-NET RS 485 INT. MAIN PANEL J1&J2OFF SUB PANEL or REPEATERS J1&J2ON J-NET-RS485-INT-NEW J-NET-RS485-INT-NEW REMEMBER TO ONFIGURE JUMPERS!! REMEMBER TO ONFIGURE JUMPERS!! MAIN PANEL REPEATER PANEL ON 5 J-NET-ON ON 3 RS485 INTERFAE ON 5 J-NET-ON ON 3 RS485 INTERFAE PIN#1 PIN#2 PIN#3 PIN#4 PIN#5 PIN#1 PIN#2 PIN#3 PIN#4 PIN#5 PIN#1 PIN#2 PIN#3 PIN#4 PIN#5 PIN#1 PIN#2 PIN#3 PIN#4 PIN#5 (EN54) INSTALLATION & OMMISSIONING MANUAL - REVISION OT 4,

37 LK 2 LK 1 GLOBAL INSTALLATION Main Panel Fibre Optic Use a single FIBRE OPTI INTERFAE BOARD instead of the RS485 INTERFAE BOARD. STF2 and STF4 on one side of the PB can be considered the IN connection. STF1 and STF3 on the other side of the PB can be considered the connection. onnection is made using fibre optic cable instead of copper cable. The ends of the fibre must be terminated with ST type Fibre-optic connectors. NOTE:At the Main Panel, LK1 & LK2 should be removed. Failure to do so will inhibit communication between the Main panel and the Sub-panels. STF1 RX TX STF3 STF4 TX RX STF2 J-NET-INT-FO Repeater Fibre Optic Use a single FIBRE OPTI INTERFAE BOARD instead of the RS485 INTERFAE BOARD. STF2 and STF4 on one side of the PB can be considered the IN connection. STF1 and STF3 on the other side of the PB can be considered the connection. onnection is made using fibre optic cable instead of copper cable. The ends of the fibre must be terminated with ST type Fibre-optic connectors. NOTE:At the Repeater Board, LK1 & LK2 should be fitted. Failure to do so will inhibit communication between the Main panel and the Sub-panels. (EN54) INSTALLATION & OMMISSIONING MANUAL - REVISION OT 4,

38 LK 2 LK 1 GLOBAL Fibre Optic External onnection INSTALLATION The dual fibre external fibre optic connections should be made as below: Main Panel LOOP STF1 (Tx) STF3 (Rx) First Sub-panel or Repeater LOOP IN STF4 (Rx) STF2 (Tx) Then continue to connect of one Repeater/Sub-panel to IN of the next Repeater/Sub-Panel following the same connection rules as above. When you reach the last Repeater/Sub-panel in the loop make the connections as follows: Main Panel LOOP IN STF4 (Rx) STF2 (Tx) Last Sub-panel or Repeater LOOP STF1 (Tx) STF3 (Rx) STF1 RX TX STF3 STF4 TX RX STF2 J-NET-INT-FO (EN54) INSTALLATION & OMMISSIONING MANUAL - REVISION OT 4,

39 GLOBAL INSTALLATION Analogue Loops The Analogue Loops provide the connection to all the analogue addressable devices and loop powered sounders. Unless the loop is completed the panel will not be able to monitor its integrity (open and short circuit monitoring). Unused Analogue Loops should have wire links fitted. onnection to the Analogue Loop is via the ANALOGUE LOOP ONNETION BOARD in Main Panels or Repeaters with Integrated Sub-panels and via dedicated connectors on Standard Subpanels. Standard Sub-panels may be located within the Main Panel box or housed externally. Loop onnectors ETH SNDR 1 SNDR 2 LOOP 1 LOOP 1 LOOP 2 LOOP 2 LOOP 3 LOOP 3 N3 N4 LOOP 1 LOOP R7 35 MPX N5 LOOP 2 LOOP 2 Loop onnectors J-NET-LPON LOOP 3 LOOP 3 H8/3003 OMMS OK OMMS FLT FAULT PRE-ALARM FIRE 5VOLTFAULT PANEL NO SILENE A ON BATT 24V EVA MAX 3A FAST ATING J-NET-SP with LOOP-ARD 0V 24V MON 0V 0V 28V 28V AUX PS POWER SUPPLY IN Devices that can be fitted to the Analogue Loop include smoke sensors, heat sensors, Zone Monitor Units (ZMU), I/O units, loop sounders and manual call-points. (EN54) INSTALLATION & OMMISSIONING MANUAL - REVISION OT 4,

JUNO-NET. Fire Alarm Control Panel OPERATION & MAINTENANCE MANUAL

JUNO-NET. Fire Alarm Control Panel OPERATION & MAINTENANCE MANUAL Fire Alarm Control Panel & MANUAL CONTENTS SECTION -. Description of the fire control panel fascia.... Alarm.... Reset the system.... Sound and silence the alarms.... Read the Fire, Fault, Test and Disabled

More information

ORION Mini-Rep INSTALLATION MANUAL

ORION Mini-Rep INSTALLATION MANUAL ORION Mini-Rep INSTALLATION MANUAL Orion Mini-Rep - INSTALLATION MANUAL - REVISION 1.0-04/007 The Orion Mini-Rep will provide remote control and system display status from multiple locations to an Orion

More information

Installation, Operating and Maintenance Manual

Installation, Operating and Maintenance Manual STATUS ZONES CONTROLS FIRE FAULT DISABLED FIRE 1 2 3 4 5 6 7 8 TEST FAULT DISABLED 1 5 BUZZER SILENCE RESET 1 2 TEST 2 6 LAMP TEST 3 SUPPLY 3 7 SYSTEM FAULT 4 8 SOUNDERS ACTIVATE/ SILENCE 4 FAULTS INSTRUCTIONS

More information

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel INSTALLATION, OPERATION AND MAINTENANCE MANUAL Version: CN-PM-1000.VER1.1-12/2012 EN54 INFORMATION In accordance with EN 54-2 clause 13.7, the maximum

More information

1 INTRODUCTION NOTICE WARNINGS AND CAUTIONS NATIONAL APPROVALS EMC COMPATIBILITY UNPACKING...

1 INTRODUCTION NOTICE WARNINGS AND CAUTIONS NATIONAL APPROVALS EMC COMPATIBILITY UNPACKING... ZXA / ZXE FIRE ALARM CONTROL PANEL MORLEY-IAS Table of Contents 1 INTRODUCTION...1 1.1 NOTICE... 1 1.2 WARNINGS AND CAUTIONS... 1 1.3 NATIONAL APPROVALS... 2 1.4 EMC COMPATIBILITY... 2 2 UNPACKING...3

More information

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL PRODUCT Specification FEATURES Designed To Meet The Requirements Of EN54 Expandable From 1 To 5 Loops As Standard A Variety Of Networking Options

More information

The EN54 Part 2 & 4 Fire System

The EN54 Part 2 & 4 Fire System Scope of work: To design, supply, install and commission an Analogue Addressable Fire Alarm Control System in accordance with the details specified herein and in accordance with supplied drawings The EN54

More information

Written by: A.C. Amended by G.G. Checked by: JBJ/PB Approved by:jbj

Written by: A.C. Amended by G.G. Checked by: JBJ/PB Approved by:jbj Written by: A.C. Amended by G.G. Checked by: JBJ/PB Approved by:jbj Control Equipment Limited 32 Zone, 40 Character Discovery Panel, Voyager Panel and Integra Network Repeater Installation, Commissioning

More information

Intelligent Security & Fire Ltd

Intelligent Security & Fire Ltd full installation, commissioning and operating manuals can be downloaded from www.haes-systems.co.uk combined addressable / conventional fire alarm control panel User Guide Approved Document No. MFBU-04

More information

FireNET Plus Wiring Instructions

FireNET Plus Wiring Instructions FireNET Plus Wiring Instructions This manual provides wiring instructions for the 1 loop and 2 loop version of the FireNET Plus panels, which supports our finest Hochiki s DCP protocol. Note: Refer to

More information

Application, Installation, Operation & Maintenance Manual

Application, Installation, Operation & Maintenance Manual APPROVED BY:JBJ PRESCIENT III FIRE ALARM & GAS EXTINGUISHING CONTROL PANEL Application, Installation, Operation & Maintenance Manual PAGE 1 of 43 CONTENTS 1. INTRODUCTION... 3 2. GENERAL DESCRIPTION...

More information

Excel-EN Conventional Fire Control Panel

Excel-EN Conventional Fire Control Panel Available as 2, 4, 6, 8,10 or 12 zones Approved to EN54-2 & 4 Modular expansion zone cards Programmable relays and outputs Optional additional sounder circuits Optional additional programmable outputs

More information

OPERATION AND INSTALLATION MANUAL

OPERATION AND INSTALLATION MANUAL EX+Plus 2 ZONE, 1AREA EXTINGUISHANT CONTROL PANEL OPERATION AND INSTALLATION MANUAL INTRODUCTION The Premier EX Plus is a 2 zone, single area panel for controlling the release of extinguishing gases in

More information

STANDARD TECHNICAL SPECIFICATION FOR AN ANALOGUE ADDRESSABLE FIRE DETECTION SYSTEM

STANDARD TECHNICAL SPECIFICATION FOR AN ANALOGUE ADDRESSABLE FIRE DETECTION SYSTEM STANDARD TECHNICAL SPECIFICATION FOR AN ANALOGUE ADDRESSABLE FIRE DETECTION SYSTEM Revision 2: November 1998 INDEX 1. SCOPE 2. GENERAL DESCRIPTION 3. STANDARDS 4. SYSTEM OPERATION 4.1 ACCESS LEVELS 4.2

More information

ZXSe Range Data Sheet

ZXSe Range Data Sheet ZXSe Range Data Sheet Analogue addressable fire alarm control panel Product Overview The ZXSe range of analogue addressable fire alarm control panels have been designed and constructed around proven and

More information

PERTRONIC INDUSTRIES LTD F4-RMAX Installation Note

PERTRONIC INDUSTRIES LTD F4-RMAX Installation Note Product Overview: The Pertronic F4 Remote LED Mimic / Aux Relay Module F4-RMAX is an optional extra for the Pertronic F4 conventional 4-zone fire alarm panel. This board enables the fire alarm panel to

More information

The EN54 Part 2, 4 and 13 Fire System

The EN54 Part 2, 4 and 13 Fire System Scope of work: To design, supply, install and commission an Analogue Addressable Fire Alarm Control System in accordance with the details specified herein and in accordance with supplied drawings The EN54

More information

Solution F2. Fire Alarm Control Panels one step ahead.

Solution F2. Fire Alarm Control Panels one step ahead. Solution F2 Fire Alarm Control Panels one step ahead. Sicherheitstechnik Sicherheitstechnik GmbH GmbH The Fire Alarm Control Panel Solution F2 Solution F2 in B2 enclosure (B01090-00) The Concept The Solution

More information

General Routing Interface

General Routing Interface General Routing Interface Features The General Routing Interface Card is an optional module to provide Fire and Fault Routing Outputs compliant with BSEN54-2: 1998 Clauses 7.9 and 8.9 and BS5839-1: 2002.

More information

Discovery 1-4 Loop 32 Zone, 40 Character Analogue Addressable Control Panel. Application Guide

Discovery 1-4 Loop 32 Zone, 40 Character Analogue Addressable Control Panel. Application Guide Discovery 1-4 Loop 32 Zone, 40 Character Analogue Addressable Control Panel Application Guide Contents Page 1.0 Introduction and Typical System Illustration 2 2.0 Cabinet Specifications 4 3.0 Hardware

More information

FireShield Plus. GE Security. EST Life Safety & Communications Conventional Small Building Solutions. Conventional Fire Alarm Control Panels

FireShield Plus. GE Security. EST Life Safety & Communications Conventional Small Building Solutions. Conventional Fire Alarm Control Panels GE Security EST Life Safety & ommunications onventional Small Building Solutions Overview The FireShield Plus fire alarm family consists of 3, 5 and 10 zone conventional fire alarm s, an integrated DAT/Dialer,

More information

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices. FireCell Radio Hub Fully addressable Wireless activation Third party approved (EN54) 2-way radio communication Loop powered Diagnostics port Range in excess of 150 metres Overview The model FCX-500-001

More information

Document No Issue 4 user manual

Document No Issue 4 user manual DX Document No. 996-148-000-4 Issue 4 user manual Dimension Series Table of Contents 1 INTRODUCTION... 5 1.1 NOTICE... 5 1.2 MODELS... 5 1.3 WARNINGS AND CAUTIONS... 7 1.4 NATIONAL APPROVALS... 7 1.5 EN54

More information

1 INTRODUCTION NOTICE WARNINGS AND CAUTIONS NATIONAL APPROVALS EN54 INFORMATION UNPACKING...

1 INTRODUCTION NOTICE WARNINGS AND CAUTIONS NATIONAL APPROVALS EN54 INFORMATION UNPACKING... ZX Fire Alarm Control Panels MORLEY-IAS Table of Contents 1 INTRODUCTION...1 1.1 NOTICE...1 1.2 WARNINGS AND CAUTIONS...1 1.3 NATIONAL APPROVALS...2 1.4 EN54 INFORMATION...2 2 UNPACKING...4 3 INSTALLATION...5

More information

ANALOGUE ADDRESSABLE FIRE CONTROL PANELS FIREQUEST FAMILY. Section 6 Trouble Shooting Issue 1.1

ANALOGUE ADDRESSABLE FIRE CONTROL PANELS FIREQUEST FAMILY. Section 6 Trouble Shooting Issue 1.1 FIREQUEST FAMILY ANALOGUE ADDRESSABLE FIRE CONTROL PANELS FIREQUEST FAMILY Section 6 Trouble Shooting Issue 1.1 FireQuest - trading as Luminos Lighting Ltd Unit F1, Grafton Way Basingstoke, Hampshire RG22

More information

Conventional Fire Alarm Systems

Conventional Fire Alarm Systems Kidde atalog u Small Building Fire Alarm Solutions Technology that saves lives onventional Fire Alarm Systems FX-10RD, FX-10R, FX-5RD, FX-5R OA 6230 Overview Kidde brand conventional fire alarm systems

More information

FIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module

FIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module FIRE ALARM CONTROL EQUIPMENT Addendum October 2006 Instructions for new style EN54-4 Power supply unit module MXLK-05 Issue 2.0 June 2007 INSTALLATION Safety Suppliers of articles for use at work are required

More information

Fire Alarm Panels. Product Manual.

Fire Alarm Panels. Product Manual. Fire Alarm Panels Product Manual The operation and functions described in this manual are available from Software Version 5000-050-04 onwards. Specifications: Item Specification Details Part Number: Mx-5100

More information

FEC400 Series. Installation Manual

FEC400 Series. Installation Manual FEC400 Series Conventional microprocessor controlled fire detection and alarm panels with extinguishing control Installation Manual Version 2.3 / August 2004 Aritech is a GE Interlogix brand. http://www.geindustrial.com/ge-interlogix/emea

More information

GE Security. FP1200, FP2000 and KSA1200 series fire panels, repeaters and emulators Interconnection and wiring

GE Security. FP1200, FP2000 and KSA1200 series fire panels, repeaters and emulators Interconnection and wiring GE Security FP1200, FP2000 and KSA1200 series fire panels, repeaters and emulators Interconnection and wiring Version v2-2 / September 2005 Aritech and Kilsen are GE Security brands. http://www.geindustrial.com/ge-interlogix/emea

More information

Product Data Sheet. Remote Terminals. Features:

Product Data Sheet. Remote Terminals. Features: Remote Terminals Product Data Sheet Features: Based around two core products, the Mx- 4010 Remote Display Terminal (RDT) and the fully functional Mx-4020 Remote Control Terminal (RCT). Both remote terminals

More information

VSN-RP1r Extinguishing Control Panel. User Manual (Software version 3.x) by Honeywell. doc. MIE-MN-570I rev.008

VSN-RP1r Extinguishing Control Panel. User Manual (Software version 3.x) by Honeywell.   doc. MIE-MN-570I rev.008 www.morley-ias.es by Honeywell VSN-RP1r Extinguishing Control Panel User Manual (Software version 3.x) doc. MIE-MN-570I rev.008 Information in this document is subject to change without notice. 22 June

More information

Syncro Matrix Analogue Addressable Fire Alarm Mimic Panel Product Manual

Syncro Matrix Analogue Addressable Fire Alarm Mimic Panel Product Manual Syncro Matrix Analogue Addressable Fire Alarm Mimic Panel Product Manual Australia Issue 01 April 2012 Contents 1 Introduction 3 2 Safety 3 3 Installation 4 3.1 Mounting the Cabinet 4 4 Specifications

More information

Discovery 1-4 Loop 96 Zone, 40-Character Analogue Addressable Control Panel. Application Guide

Discovery 1-4 Loop 96 Zone, 40-Character Analogue Addressable Control Panel. Application Guide Discovery 1-4 Loop 96 Zone, 40-Character Analogue Addressable Control Panel Application Guide Contents Page 1.0 Introduction and Typical System Illustration 2 2.0 Cabinet Specifications 4 3.0 Hardware

More information

Control Panel Engineering and Commissioning Manual (TO BE RETAINED BY THE COMMISSIONING ENGINEER)

Control Panel Engineering and Commissioning Manual (TO BE RETAINED BY THE COMMISSIONING ENGINEER) Fire Detection & Alarm System Control Panel (Suitable for TWINFLEX pro control panels from V2.00) Control Panel Engineering and Commissioning Manual (TO BE RETAINED BY THE COMMISSIONING ENGINEER) 26-0959

More information

ZXSe Range. Fire Safety. Analogue addressable fire alarm control panel KEY FEATURES. Panel Features

ZXSe Range. Fire Safety. Analogue addressable fire alarm control panel KEY FEATURES. Panel Features Fire Safety ZXSe Range Analogue addressable fire alarm control panel The ZXSe range of analogue addressable fire alarm control panels have been designed and constructed around proven and reliable microprocessor

More information

SERIES 3000 INTELLIGENT FIRE ALARM CONTROL PANEL ENGINEERING PROGRAMING MANUAL TABLE OF CONTENTS.. 1 INTRODUCTION.. 3 SYSTEM POWER UP.

SERIES 3000 INTELLIGENT FIRE ALARM CONTROL PANEL ENGINEERING PROGRAMING MANUAL TABLE OF CONTENTS.. 1 INTRODUCTION.. 3 SYSTEM POWER UP. SERIES 3000 INTELLIGENT FIRE ALARM CONTROL PANEL ENGINEERING PROGRAMING MANUAL TABLE OF CONTENTS.. 1 INTRODUCTION.. 3 SYSTEM POWER UP. 3 1 PANEL SWITCHES. 3 FIRE ZONE LAMP 4 OTHER LAMPS 4 MULTIPLEX OUTPUT.

More information

Intelligent addressable fire alarm control panel

Intelligent addressable fire alarm control panel Intelligent addressable fire alarm control panel Input current consumption: Panel rating: Batteries: Networking and Interfaces Panel to panel communication: Number of panels: Interface port: System capacity

More information

SmartTerminal AS7240. Installation and Operation Guide MAN2990-1

SmartTerminal AS7240. Installation and Operation Guide MAN2990-1 SmartTerminal AS7240 Installation and Operation Guide MAN2990-1 Table of Contents Page No. 1 Introduction... 3 2 Mechanical... 4 2.1 Mounting the Enclosure... 4 2.1.1 Enclosure Details... 4 2.1.2 Fixing

More information

PWGSC Ontario MULTIPLEX FIRE ALARM SYSTEM Sect Region Project Page 1 Number R

PWGSC Ontario MULTIPLEX FIRE ALARM SYSTEM Sect Region Project Page 1 Number R Region Project Page 1 PART 1 - GENERAL 1.1 REFERENCES.1 CAN/ULC-S524-2006, Standard for the Installation of Fire Alarm Systems..2 CAN/ULC-S525-2007, Audible Signal Device for Fire Alarm Systems..3 CAN/ULC-S526-2007,

More information

An introduction to... Sigma

An introduction to... Sigma An introduction to... Sigma XT+ Sigma XT+ Overview The Sigma XT+ 21000 series are the latest additions to the Sigma family of control equipment from Kentec Electronics Limited. The Sigma XT+ range combines

More information

System 800 Addressable Fire Detection & Alarm System

System 800 Addressable Fire Detection & Alarm System SECTION 5: page 1 Section 5: System 800 Addressable Fire Detection & Alarm System SECTION 5: page 3 10 reasons to specify 800 1 Plug and Play A user friendly panel not requiring special software tools

More information

E-FSC. Conventional Fire Alarm Control Panels. Standard Features. Overview

E-FSC. Conventional Fire Alarm Control Panels. Standard Features. Overview Edwards Signaling atalog u Fire Alarm ontrol Panels E-FS onventional Fire Alarm ontrol Panels Overview The E-FS fire alarm family consists of 3, 5 and 10 zone conventional fire alarm s, an integrated DAT/Dialer,

More information

Algo-Tec 6300 INTERACTIVE DIGITAL ADDRESSABLE FIRE CONTROL SYSTEM (1-4 LOOPS)

Algo-Tec 6300 INTERACTIVE DIGITAL ADDRESSABLE FIRE CONTROL SYSTEM (1-4 LOOPS) Algo-Tec 6300 INTERACTIVE DIGITAL ADDRESSABLE FIRE CONTROL SYSTEM (1-4 LOOPS) INSTALLATION MANUAL Protec Fire Detection PLC, Protec House, Churchill Way, Nelson, Lancashire, BB9 6RT. Telephone: +44 (0)

More information

TotalPac 3 Deluge, Electric release Self-contained system

TotalPac 3 Deluge, Electric release Self-contained system (Optional) DESRIPTION This TOTALPA 3 integrated fire protection system by FireFlex Systems Inc. consists of a deluge system trim totally preassembled, pre-wired and factory tested. All electrical and mechanical

More information

DS7400Xi Addressable Control/ Communicator

DS7400Xi Addressable Control/ Communicator DS7400Xi Addressable Control/ Communicator DS7400Xi DS7400Xi-EXP 110VAC operation 220VAC operation Remotely Programmable WDSRP (Windows Detection Systems Remote Programming Software), allows the systems

More information

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS QUICK USER GUIDE FOR, 2 & 4 ZONE PANELS INDICATORS COLOUR INDICATION MON FAULT Yellow On when a fault condition has occurred, or if no other fault Led is on, this indicates 24v auxiliary fuse failure.

More information

4100S. The operation and functions described in this manual are available from Software Version 4100S onwards.

4100S. The operation and functions described in this manual are available from Software Version 4100S onwards. 4100S The operation and functions described in this manual are available from Software Version 4100S-023-013 onwards. Specifications: Item Specification Details Enclosure Steel IP30 Dimensions H x W x

More information

PS914 Power Supply. 900-KL Keylock (optional) Page BB Battery Backup (optional) Page 3

PS914 Power Supply. 900-KL Keylock (optional) Page BB Battery Backup (optional) Page 3 F1! DANGER 44487056 These instructions cover the following parts: PS914 Power Supply Installation Instructions! DANGER: To avoid risk of electric shock, turn off A power before installing or servicing

More information

XP95/Series 90 Test Set

XP95/Series 90 Test Set PP1072/2003/Issue 5 XP95/Series 90 Test Set XP95/SERIES 90 TEST SET BIT 0 BIT 1 BIT 2 NEW TEST MIN/MAX DOWN * UP # LOOP POWER OFF ON OUTPUT HEALTHY LOOP + - User Manual 1 Apollo XP95/Series 90 Test Set

More information

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

Syncro AS. Analogue Addressable Fire Control Panel. User Manual Syncro AS Analogue Addressable Fire Control Panel User Manual Man-1100 Issue 02 Nov. 2008 Index Section Page 1. Introduction...3 2. Safety...3 3. Panel Controls...4 3.1 Access Level 1...4 3.2 Access Level

More information

Discovery 4 Loop Analogue Addressable Control Panel (NVI & NVA series Protocols)

Discovery 4 Loop Analogue Addressable Control Panel (NVI & NVA series Protocols) Nitin Ventures FZE. (A Division of Nitin Fire Protection Industries Ltd.) BETTER TO BE SAFE Discovery Analogue Addressable Fire Alarm Panels Discovery 4 Loop Analogue Addressable Control Panel (NVI & NVA

More information

MODUL-R FIRE ALARM CONTROL PANELS. MR-2900/MR-2920 Addressable Fire Alarm Control Panels MEA. Features. Description

MODUL-R FIRE ALARM CONTROL PANELS. MR-2900/MR-2920 Addressable Fire Alarm Control Panels MEA. Features. Description MODUL-R FIRE ALARM CONTROL PANELS MR-2900/MR-2920 Addressable Fire Alarm Control Panels Description MR-2900 Fire Alarm Control Panel The MR-2900 fire alarm system control unit is the heart of a sophisticated

More information

OPERATION / INSTALLATION

OPERATION / INSTALLATION OPERATION / INSTALLATION & PROGRAMMING MANUAL AFP-2800 LCD-80 Fire Alarm Panel Revision 1.01 November 16, 2004 NSW (Head Office) 7 Columbia Court Norwest Business Park Baulkham Hills NSW 2153 Ph: (02)

More information

Fire Extinguishing Control Panel INSTRUCTION MANUAL. Revision 8/ Instruction Manual Page 1 Revision 8/01.17 of 63

Fire Extinguishing Control Panel INSTRUCTION MANUAL. Revision 8/ Instruction Manual Page 1 Revision 8/01.17 of 63 Fire Extinguishing Control Panel FS5200Е INSTRUCTION MANUAL Revision 8/01.17 Instruction Manual Page 1 1. 2. 3. 4. 4.1. 4.2. 4.2.1. 4.2.2. 4.2.3. 4.2.4. 4.2.5. 4.2.6. 4.2.7. 4.2.8. 4.2.9. 4.2.10. 4.2.11.

More information

Remote NAC Power Supply D7038

Remote NAC Power Supply D7038 Operation and Installation Guide Remote NAC Power Supply D7038 D7038 REMOTE NAC POWER SUPPLY Page 2 2005 Bosch Security Systems Contents Contents 1.0 Overview...5 1.1 Module Control...5 1.1.1 Option Bus

More information

Installation Manual Premier 412/816/832. Issue 10

Installation Manual Premier 412/816/832. Issue 10 Installation Manual Premier // Issue 0 Premier // Installation Manual 5. Operating the System Introduction Before attempting to operate the alarm system ensure you have familiarised yourself with all the

More information

user manual Document No , Revision 03 November 2015

user manual Document No , Revision 03 November 2015 user manual Document No. 996-202-600-3, Revision 03 November 2015 Contents 1 Introduction...1 1.1 Notice...1 1.2 Models...1 2 User Control Levels...2 2.1 Level Definition...2 2.2 User Passwords...2 3 Controls

More information

System Manual W A R N I N G. PC6O1O Software Version 2.1

System Manual W A R N I N G. PC6O1O Software Version 2.1 System Manual W A R N I N G This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer. The entire manual

More information

Fratech Multipath-IP

Fratech Multipath-IP Rev 2.0 (May 2013) Installer Manual 1 Current Part Numbers: Fratech Multipath-IP E-Link STU PCB & Accessory Kit only In Metal Enclosure with Power Supply 998325-PK 998325-XS Installer Manual This document

More information

Intelligent Security & Fire Ltd

Intelligent Security & Fire Ltd Product Data Sheet Mx-4000 Series User Manual MX-4100, MX-4200, MX-4400, Mx-4400/LE & Mx-4800 Fire Alarm Control Panels The operation and functions described in the manual are available from Software Versions

More information

TECHNICAL DATA OBSOLETE

TECHNICAL DATA OBSOLETE Deluge Devices 270a 1. PRODUCT NAME VIKING PAR-3 Available since 1991 2. MANUFACTURED FOR: THE VIKING CORPORATION 210 N. Industrial Park Road Hastings, Michigan 49058 U.S.A. Telephone: (269) 945-9501 (877)

More information

SOFTWARE VERSION 2.20 CONTROL PANEL RESET: Installer lock must be unlocked. (Address 255: enter any value other than 147)

SOFTWARE VERSION 2.20 CONTROL PANEL RESET: Installer lock must be unlocked. (Address 255: enter any value other than 147) -961112-0003 SOFTWARE VERSI 2.20 CTROL PANEL RESET: Installer lock must be unlocked. ( 255: enter any value other than 147) Power down reset (1) Remove battery and AC to power down the unit. (4) Wait 3

More information

DOOR MONITORING/DURESS SYSTEM

DOOR MONITORING/DURESS SYSTEM SECTION PART 1 - GENERAL 1.1 RELATED SECTIONS A. Comply with the requirements of Section 27 05 00 Common Work Results for Communications. 1.2 DEFINITIONS A. Not used. 1.3 DESCRIPTION OF SYSTEM: A. Provide

More information

BS-316. Gas detection control panel up to 16 inputs. Installation operation manual

BS-316. Gas detection control panel up to 16 inputs. Installation operation manual BS-316 Gas detection control panel up to 16 inputs Installation operation manual Page 1 from 21 Contents 1 Operation instructions--------------------------------------------------------------------------------------------------------------------3

More information

Esmi Sense FDP Fire detection panel with ALC2 loop controller

Esmi Sense FDP Fire detection panel with ALC2 loop controller Esmi Sense FDP Fire detection panel The intelligent and modular Esmi Sense FDP fire detection panel provides multiple new features for efficient and reliable fire safety. The Esmi Sense FDP fire detection

More information

5000 INSTALLATION GUIDE

5000 INSTALLATION GUIDE 5000 INSTALLATION GUIDE Table of Contents Section Page No 1. INTRODUCTION... 3 2. WARNINGS AND CAUTIONS... 3 3. UNPACKING... 3 4. INSTALLATION... 4 5. CONTROL PANEL - REMOVING ITEMS BEFORE MOUNTING...

More information

ZSC100 Gas Detection and Alarm System Controller

ZSC100 Gas Detection and Alarm System Controller ZSC100 Gas Detection and Alarm System Controller User Guide 1- Introduction... 3 1.1- General description... 3 1.2- Cautions and warnings... 3 2- Control panel... 4 2.1 Control panel overview... 4 2.2

More information

SOLO Single Loop Addressable Fire Control Panel

SOLO Single Loop Addressable Fire Control Panel Solo Single Loop Analogue Addressable Fire Control Panel Apollo Protocol Installation, Commissioning & Operating Manual Issue 03 June 1999 CONTENTS Section... Page 1. Introduction...1 2. Safety...2 3.

More information

DCS-100. intelligent damper control & monitoring system

DCS-100. intelligent damper control & monitoring system DCS-100 intelligent damper control & monitoring system 02 //DCS-100 Introduction The Disys Technologies DCS-100 is a revolutionary new control system designed specifically for the fire/smoke damper controls

More information

Saxon Range 1-8 Zone Convertional Control Panels

Saxon Range 1-8 Zone Convertional Control Panels Tel: 00448450751042 Fax: 00448450751043 Email: info@fireguarduk.com 2nd FLOOR 145157 ST.JOHNS STREET LONDON EC1V 4PY UNITED KINGDOM 18 Zone Convertional Control Panels Key Features Builtin detector removal

More information

Syncro AS. Analogue Addressable Fire Control Panel. Product Manual

Syncro AS. Analogue Addressable Fire Control Panel. Product Manual Syncro AS Analogue Addressable Fire Control Panel Product Manual Man-1096 Issue 05 Nov 2008 Index Section Page 1. Introduction...4 2. Safety...4 3. Installation...5 4. Cabling...6 4.1 Cable Termination...

More information

Document No Issue 02 operation & installation manual. ZXr-A ZXr-P

Document No Issue 02 operation & installation manual. ZXr-A ZXr-P ZXr-A ZXr-P Document No. 996-144 Issue 02 operation & installation manual MORLEY-IAS ZXr-A / ZXr-P Repeaters Table of Contents 1 INTRODUCTION... 3 1.1 NOTICE... 3 1.2 WARNINGS AND CAUTIONS... 3 1.3 NATIONAL

More information

SOFTWARE VERSION 2.20 CONTROL PANEL RESET:

SOFTWARE VERSION 2.20 CONTROL PANEL RESET: -961112-0002 SOFTWARE VERSI 2.20 CTROL PANEL RESET: Installer lock must be unlocked. ( 255: enter any value other than 147) Power down reset (1) Remove battery and AC to power down the unit. (4) Wait 3

More information

1) This manual covers 4400, 5400 and 6400 fire alarm systems. The differences are described in the appropriate sections.

1) This manual covers 4400, 5400 and 6400 fire alarm systems. The differences are described in the appropriate sections. ISSUES ISSUE DATE DETAILS OF CHANGE CHANGED BY 1 16/02/00 ORIGINAL ISSUE - 2 16/01/01 TABLES 2 & 3 UPDATED, ADDED TABLE 4 PWD 3 12/09/01 ADDITIONAL INFORMATION PWD 4 29/11/02 TABLES 2, 3 & 4 UPDATED &

More information

Fire control panel detect 3004 plus and accessories

Fire control panel detect 3004 plus and accessories Fire control panel detect 3004 and accessories The modular fire alarm panel detect 3004 is the basic version of a broad product portfolio of the system detect 3000. Up to 20 fire control panels can be

More information

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING -961212-0004 SOFTWARE VERSION 3.10 CONTROL PANEL RESET: Installer lock must be unlocked. ( 058: enter any value other than 147) Power down reset (1) Remove battery and AC to power down the unit. (2) Connect

More information

SIMPLICITY CO CARBON MONOXIDE DETECTION & VENTILATION PANEL

SIMPLICITY CO CARBON MONOXIDE DETECTION & VENTILATION PANEL SIMPLICITY CO CARBON MONOXIDE DETECTION & VENTILATION PANEL USER MANUAL 1 Table of Contents 1 SAFETY INFORMATION...3 1.1 SAFETY PRECAUTIONS DURING NORMAL OPERATION OF PANEL...3 1.3 BATTERY INFORMATION...3

More information

1200-HCM DIN RAIL MOUNTING FIRE SYSTEM MODULE Fire Detection & Extinguishant Control A R T PATOL LIMITED SUPPLY FAULT SOUNDER

1200-HCM DIN RAIL MOUNTING FIRE SYSTEM MODULE Fire Detection & Extinguishant Control A R T PATOL LIMITED SUPPLY FAULT SOUNDER Application The unit is primarily intended for use where there is a requirement to integrate a limited fire protection function into a larger control equipment scheme, or in specialist applications where

More information

Intelligent 2 & 4 Loop Fire Alarm Control Panels

Intelligent 2 & 4 Loop Fire Alarm Control Panels Intelligent 2 & 4 Loop Fire Alarm Control Panels Advanced has combined the latest technology with many years of fire experience, to create the Axis AX Series Intelligent Fire Alarm Control Panels. The

More information

Fire Control Panel. Installation & Programming Manual TABLE OF CONTENTS

Fire Control Panel. Installation & Programming Manual TABLE OF CONTENTS Fire Control Panel Installation & Programming Manual TABLE OF CONTENTS Page Getting Started 2 Power Supply Unit 3 Remote Keypad Bus 3 Inputs & Outputs 4 User Keypad Functions 5 Engineer Keypad Functions

More information

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features 990-052, Issue 6 20 March 2006 ID50 Series Single Loop Intelligent Fire Alarm Panels Section: Intelligent Fire Alarm Panels GENERAL The NOTIFIER ID50 series single loop intelligent fire alarm panels, has

More information

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum. September 29, 1997 Firecycle III 433 a 1. PRODUCT NAME VIKING Model E-1 Manufactured 1997 Present 2. MANUFACTURED FOR THE VIKING CORPORATION 210 N Industrial Park Road Hastings, Michigan 49058, U.S.A.

More information

Surveyor Excel. Fire Alarm Control Equipment Network version. Programming Manual MASTER MANUAL. VERSION 14.0 and Above

Surveyor Excel. Fire Alarm Control Equipment Network version. Programming Manual MASTER MANUAL. VERSION 14.0 and Above Surveyor Excel Fire Alarm Control Equipment Network version Programming Manual VERSION 14.0 and Above MASTER MANUAL Drawing S1606. PCB Layout guide for XLK range of control panels FCPXLK-2/4/6/8 & FCPXLK2/4/6/8TW

More information

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING 48ESEP-01 SOFTWARE VERSION 3.10 CONTROL PANEL RESET: Installer lock must be unlocked. (Address 058: enter any value other than 147) Power down reset (1) Remove battery and AC to power down the unit. (2)

More information

Fire detection and alarm system Installation instructions

Fire detection and alarm system Installation instructions Fire detection and alarm system Installation instructions Installation instructions Table of Contents Table of Contents ------------------2 Preface -----------------------3 Associated Documents 3 Conventions

More information

ED820-24V MODEL INSTRUCTION MANUAL. fire DETECTOR

ED820-24V MODEL INSTRUCTION MANUAL. fire DETECTOR ED820 24V MODEL fire DETECTOR INSTRUCTION MANUAL Address: Enigma House, Enigma Business Park, Malvern, Worcestershire, WR14 1GD Tel: 44 (0)1684 891500 Fax: 44 (0)1684 891600 Email: sales@electronicdevices.co.uk

More information

PANELS, KEYPADS & MODULES. Take Fire Protection to the Next Level Fire Products from DSC

PANELS, KEYPADS & MODULES. Take Fire Protection to the Next Level Fire Products from DSC Take Fire Protection to the Next Level Fire Products from DSC AFD2000 Addressable Fire Control Panel Series Provides Maximum Flexibility The new AFD2000 is a completely programmable series of addressable,

More information

Installation instructions Vigilon Compact panel based Fire detection and alarm system

Installation instructions Vigilon Compact panel based Fire detection and alarm system Installation instructions Vigilon Compact panel based Fire detection and alarm system up to 2km loop Contents Contents Notes 4 Installation 4 Second fix 4 Fixture and fittings 4 As fi tted drawings 4 Cable

More information

Smoke Vent Control Panel PCB4 V4 Installation Manual

Smoke Vent Control Panel PCB4 V4 Installation Manual Smoke Vent Control Panel PCB4 V4 Installation Manual 10A PCB4 Control Panel Do Not Remove From PCB4 Control Panel www.besafedirect.com Page 1 Contents Page 3) Important Regulations, Safety, Maintenance,

More information

DigiAir QUICK GUIDE & INSTRUCTION MANUAL

DigiAir QUICK GUIDE & INSTRUCTION MANUAL DigiAir QUICK GUIDE & INSTRUCTION MANUAL The most trusted brand in Alarm Signalling www.csldual.com @CSLDualCom CSL DualCom Limited Figure 1 - DigiAir Yellow Comms LED Red Fault LED Yellow Service LED

More information

CONTENTS. GST102A/104A/108A/116A Conventional Fire Alarm Control Panel Installation and Operation Manual

CONTENTS. GST102A/104A/108A/116A Conventional Fire Alarm Control Panel Installation and Operation Manual CONTENTS Installation Precautions... 1 EN 54 Information... 2 Chapter 1 Product Overview... 3 1.1 Features... 3 1.2 Technical Specifications... 3 1.2.1 Operating Voltage... 3 1.2.2 Batteries... 3 1.2.3

More information

Touch Screen 1 loop Addressable Fire Alarm Panel

Touch Screen 1 loop Addressable Fire Alarm Panel evolution 1 Touch Screen 1 loop Addressable Fire Alarm Panel The evolution 1 control panel offers complete compatibility with the award winning range of Nittan evolution detection and alarm devices and

More information

Product Catalogue. Intelligent Control Equipment for Life Safety. Issue 1

Product Catalogue. Intelligent Control Equipment for Life Safety.   Issue 1 Product Catalogue Intelligent Control Equipment for Life Safety Mx-Range Issue 1 Fire Detection Gas Extinguishing Hearing Impaired Alarms Disabled Refuge Alarms www.advel.co.uk CONTENTS 1 2 Introduction

More information

Consultant Specification AGILE Wireless Fire Detection System

Consultant Specification AGILE Wireless Fire Detection System Contents Scope of Work... 2 The EN54 Part 2 & 4 Fire System... 2 Standards... 2 Wireless Intelligent Photoelectric Smoke Detector Specification... 4 Wireless Intelligent Thermal Heat Detector Specification...

More information

FireFinder PLUS. Fire Alarm Control Panel (AS & 4 / AS4428-3) Installation, Commissioning & Operation MAN2994-6

FireFinder PLUS. Fire Alarm Control Panel (AS & 4 / AS4428-3) Installation, Commissioning & Operation MAN2994-6 FireFinder PLUS Fire Alarm Control Panel (AS7240 2 & 4 / AS4428-3) Installation, Commissioning & Operation MAN2994-6 FIRE BRIGADE FIRE BRIGADE RESPONSE RESPONSE GUIDE GUIDE Responding to a Fire Access

More information

Document No Issue 4 product manual

Document No Issue 4 product manual DX Document No. 997-147-000-4 Issue 4 product manual MORLEY-IAS Dimension Series Table of Contents 1 INTRODUCTION... 7 1.1 NOTICE... 7 1.2 MODELS... 7 1.3 WARNINGS AND CAUTIONS... 9 1.4 NATIONAL APPROVALS...

More information

MINERVA. Marine. Fire Detection. MX T2000 Panel Range. Features: MINERVA Marine Panel Range

MINERVA. Marine. Fire Detection. MX T2000 Panel Range. Features: MINERVA Marine Panel Range Fire Detection MINERVA Marine MX T2000 Panel Range Features: Enhances fire detection and eliminates unwanted alarms using fuzzy logic Assists fire fighting and training by providing on-screen risk management

More information

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL TABLE OF CONTENTS GENERAL DESCRIPTION... 2 STANDARD AND OPTIONAL PARTS LIST... 2 PARTS DIAGRAM... 3 TERMINAL DRAWING AND SPECIAL NOTES...

More information

2) This manual covers Fire and General Alarm systems. The differences are described in the appropriate sections.

2) This manual covers Fire and General Alarm systems. The differences are described in the appropriate sections. ISSUES ISSUE DATE RELEASED DETAILS OF CHANGE AUTHOR 4 Rev 2 September 2004 Changes for 4000 series. DB 4 Rev 3 April 2005 Screen shots updated and other minor changes K.Z. 4 Rev 4 September 2006 4 Rev

More information