CATALOG LIQUID-TUFF FLEXIBLE LIQUIDTIGHT CONDUIT CATALOG. Industrial & Commercial Liquidtight Conduit Flexible Metal Conduit A PART OF

Size: px
Start display at page:

Download "CATALOG LIQUID-TUFF FLEXIBLE LIQUIDTIGHT CONDUIT CATALOG. Industrial & Commercial Liquidtight Conduit Flexible Metal Conduit A PART OF"

Transcription

1 CATALOG LIQUID-TUFF FLIBL LIQUIDTIGHT CONDUIT CATALOG Industrial & Commercial Liquidtight Conduit Flexible Metal Conduit A PART OF

2 AFC s Flexible Liquidtight Conduit AFC Cable Systems is pleased to announce the launch of our new UL Liquidtight Flexible Steel Conduit Type LFMC NSF 169 Component for Splash Zones. This new component provides flexible conduit capabilities for use in Splash Zones with equipment and other devices associated with food production. If your application requires a product that inhibits bacteria growth and does not degrade when using bleach for cleaning and sterilization, then we have the answer. AFC s UL LFMC Liquidtight for Splash Zones is offered in Gray, Black, Red, Orange, Yellow, Green or Blue in addition to the standard White. With AFC s UL Liquid-Tuff Liquidtight Flexible Steel Conduit for Splash Zones, we ve manufactured a flexible rugged moisture, oil and sunlight resistant product designed to meet the demands of meat packing, restaurants, food processing, poultry packing and pharmaceutical facilities. We ve also redesigned new LIQUID-TUFF packaging. Our Liquidtight products now come in improved boxes, which include reinforced hand-hold knockouts, easy to read labeling with product color coding, and high visibility printed put up and trade sizes. This package allows for easy handling and storage for any jobsite. Another product enhancement is the long length reels we now offer. These newer put-ups provide inventory efficiencies, reduce waste, and allow for longer system runs. AFC s Liquid-Tuff conduits have expansive ratings that meet or exceed industry standards when compared with manufacturers in the market today. See our side by side comparison chart, on page 54. We are proud of our manufacturing processes located in the USA with quality control and process driven expertise from raw materials to finished goods. Whether you need flexible wiring raceways for harsh, oily, wet, hot, cold or hazardous environments, AFC s expansive line is ready to provide superior protection. AFC Cable Systems, Inc, your trusted partner for innovation yesterday, today and into the future.

3 Table of Contents Material Safety Data Sheet (MSDS) Industrial Liquidtight Flexible Conduit UL Hi-Low Temperature Type LFMC UL Low Smoke Zero Halogen Type LSZH, Type LFMC Non-UL Type LSZH-VF Non-UL Oil Resistant/High Temperature Liquidtight Flexible Steel Conduit Non-UL xtreme Temperature UL Orange Type LFNC-A UL NSF 169 Component for Splash Zones, Type LFMC Commercial Liquidtight Flexible Conduit UL Type LFMC (black, gray, red, orange, yellow, green) UL Computer Blue Type LFMC Non-UL VF Type LFNC-B Ultraflex Liquidtight HYDROTIT Type COM-BLU CSA Flexible Conduit HYDROTIT Type CSA CSA Flexible Conduit Flexible Metal Conduit Reduced Wall Flexible Steel Conduit Reduced Wall Aluminum Flexible Metal Conduit xtra Flexible Conduit Flexcon xtra-flexible Steel Conduit Full Wall Flexible Metal Conduit (Steel) Type RAY-FL CSA Aluminum Flexible Conduit AFC Fittings Resistance/Reference Information Chemical Resistance Guide Connector Cross-Reference Guide Product Comparison Chart Notes lectrical & Support Brands

4 SINC Flaherty, New Bedford, MA Telephone: / / Fax: / Subject: Material Safety Data Sheets (MSDS) AFC LIQUID-TUFF Flexible Conduits An official notice from OSHA confirms that the electrical products (cables, conduits, fittings, modular wiring, etc.) manufactured by AFC come under the classification of "Articles" under the Hazard Communication Standard. By definition, an article is defined as a product that does not "release or otherwise result in exposure to hazardous chemicals under normal conditions of use." Consequently, the electrical products manufactured by AFC do not require Material Safety Data Sheets. The lubricants used in the manufacturing of conduits and cables are also covered by OSHA as non-hazardous and are primarily vegetable based materials. Please contact us if you have any additional questions. 2

5 Industrial Industrial Liquidtight Flexible Conduits Industrial Liquidtight Flexible Conduit UL Hi-Low Temperature Type LFMC UL Low Smoke Zero Halogen Type LSZH, Type LFMC Non-UL Type LSZH-VF Non-UL Oil Resistant/High Temperature Liquidtight Flexible Steel Conduit Non-UL xtreme Temperature UL Orange Type LFNC-A UL NSF 169 Component for Splash Zones, Type LFMC

6 Industrial UL Hi-Low Temperature Liquidtight Flexible Steel Conduit, Type LFMC Description Superior temperature ratings Hot dipped zinc galvanized low carbon steel core UL bonding strip 3/8" 1 1 4" for grounding Sunlight resistant Flame retardant PVC jacket Grey Temperature Rating 105 C/221 F Dry -55 C/-67 F Low temperature 60 C Wet 70 C Oil resistant Applications High temperature use Machine tool wiring applications Ideal for cold climate installations Direct burial and concrete embedment Bond wire for grounding in sizes 3/8" 1 1 4" NC (6) For Hazardous Locations where Flexible Connections are required NC (B)(2)(3), (A)(2)(2), (B)(2)(2), (A)(3)(2), (B), levators, Dumbwaiters, scalators, Moving Walks, Platform Lifts, and Stairway Chairlifts per NC (A)(1)(c)(2), (A)(2)(a), (A)(2)(d)(2), (A)(3)(a), (A)(4)(2), (B)(1) and (C)(1) Information Technology quipment per NC 645.5()(2) Solar Photovoltaic (PV) Systems per NC (A) Fire Pumps per NC 695.6(D), () Site lighting and other outdoor wiring jobs References & Ratings UL 360 File NC 250, 350, 390, (B)(2)(3), (A)(2)(2), (B)(2)(2) (A)(3)(2), (B), , 553.7(B), (A), (A)(1), (C), (A)(1)(c)(2), (A)(2)(a), (A)(2)(d)(2), (A)(3)(a), (A)(3)(a), (A)(4)(2), (B)(1), (C)(1), 645.5()(2), (A)(1), , (A), 695.6(D) and () Department of Defense UL 360 adopted on October 1, 1987 Made in USA of US and/or imported materials Ordering Information Product Dimensions/Bend Radius Trade Trade Coil Reel Approx. Weight/ xternal Diameter (inches) Internal Diameter Bend Product Size Size Length Length 100 feet Over Conduit Over Jacket (min/max) Radius Code (inches) (mm) (feet) (feet) (pounds) (min/max) (min/max) inches (inches) / ' / / / / ' / / / / ' / / / / ' / / / / ' / / / / ' / / / / ' / / / ' / / / ' / / / ' / / / ' / / / ' / / / ' / / / ' / / / ' / / / ' / / / NOT: All dimensions and weights are subject to normal manufacturing tolerances. Review NC and (6) for grounding requirements. 4

7 Industrial UL Hi-Low Temperature Liquidtight Flexible Steel Conduit, Type LFMC Scope This specification covers AFC Cable Systems, Inc. UL Listed LIQUID-TUFF Hi-Low Liquidtight Flexible Steel Conduit designed for use as a raceway for power, control and communication cables in accordance with Article 350 of the National lectrical Code. The product is Underwriters Laboratories Inc. (UL) Listed for 105 C (221 F) in a dry location, 60 C (140 F) in a wet location and 70 C (158 F) in an oily location. It is also UL Listed in all trade sizes for direct burial, outdoor use and sunlight resistance. TH LIQUID-TUFF HI-LOW IS UL LISTD FOR -55 C (-67 F) LOW TMPRATUR APPLICATIONS. This Liquidtight Flexible Steel Conduit is manufactured and tested in accordance with Underwriters Laboratories Inc. Standard UL 360. The product carries the UL Listing Mark. Construction The Type Hi-Low Liquidtight Flexible Steel Conduit shall be formed from a zinc coated galvanized low carbon steel strip having a uniform width and thickness. The construction shall be in accordance with UL 360. The finished Type Hi-Low LFMC dimensions shall be in accordance with Table 5.1 of UL 360 which is summarized in Table 3. Jacket PVC A rugged moisture, oil and sunlight resistant polyvinyl chloride (PVC) jacket shall be applied directly over the flexible metal conduit with a wall thickness in accordance with Table 4.1 of UL 360 which is summarized in Table 2. Jacket: Grey Grounding Permanent circuit ground protection is provided through the continuous bonding strip built into the conduit core in sizes 3/8" through 1 1 4". A separate grounding conductor is required by the NC for trade sizes 1 1 2" and larger. LIQUID-TUFF HI LOW LFMC Reference Standards UL 360 Standard for Liquidtight Flexible Steel Conduit File Reference(s): NC Articles: UL NC 250, 350, 390, (B)(2)(3), (A)(2)(2), (B)(2)(2) (A)(3)(2), (B), , 553.7(B), (A), (A)(1), (C), (A)(1)(c)(2), (A)(2)(a), (A)(2)(d)(2), (A)(3)(a), (A)(3)(a), (A)(4)(2), (B)(1), (C)(1), 645.5()(2), (A)(1), , (A), 695.6(D) and () Department of Defense Adopted UL 360 on October 1, 1987 Markings The surface of the outer jacket shall be clearly marked with a legible print legend in compliance with UL 360. Performance Tests In accordance with UL 360, the completed LIQUID-TUFF Hi-Low Liquidtight Flexible Steel Conduit shall meet all of the performance requirements outlined in Appendix A. 5

8 Industrial UL Hi-Low Temperature Liquidtight Flexible Steel Conduit, Type LFMC Table 2 Jacket Thickness Conduit Trade Minimum Acceptable Average Trade Size Metric Designator Thickness of Jacket, (inches) 3/ / / Table 3 Conduit Diameters Acceptable Internal and xternal Diameters Appendix A UL Performance Tests Resistance and High Current Fault Current Impact Tension Crushing Pipe Stiffness Flexibility Low Temperature Flexibility Zinc Coating Vertical Flame Physical Properties Deformation Mechanical Water Absorption Moisture Penetration Sunlight Resistance Test for Secureness of Fittings Test for Durability of Ink Printing Conduit Size Internal Over Over Trade Metric Diameter, In. Conduit, In. Jacket, In. Size, In. Designator Min. Max. Min. Max. Min. Max. 3/ / /

9 Industrial Description Low Smoke Zero Halogen LSZH UL Liquidtight Flexible Metal Conduit Type LFMC Low smoke, zero halogen raceway Low toxicity generation characteristics Hot dipped zinc galvanized low carbon steel core xcellent temperature ratings Black thermoplastic polyurethane jacket UL bonding strip 3/8" 1 1 4" for grounding Sunlight resistant Flame retardant TPU jacket Temperature Rating 80 C/176 F Dry 60 C/140 F Wet 70 C/158 F Oil resistant -40 C/ 40 F Low temperatures Applications Wherever limiting toxic material of combustion is needed Direct burial and concrete embedment Bond wire for grounding in sizes 3/8" 1 1 4" NC (6) Hazardous Locations where Flexible Connections are required per NC (B)(2)(3), (A)(2)(2), (B)(2)(2), (A)(3)(2), (B), Ordering InformationProduct Dimensions/Bend Radius References & Ratings UL 360 File NC 250, 350, 390, (B)(2)(3), (A)(2)(2), (B)(2)(2) (A)(3)(2), (B), , 553.7(B), (A), (A)(1), (C), (A)(1)(c)(2), (A)(2)(a), (A)(2)(d)(2), (A)(3)(a), (A)(3)(a), (A)(4)(2), (B)(1), (C)(1), 645.5()(2), (A)(1), , (A), 695.6(D) and () Department of Defense UL 360 adopted on October 1, 1987 ASTM 162 Flame Spread Index ASTM 662 Smoke Density Generation Bombardier SMP-800C Toxic Gas Generation UL 94 Tests for Flammability of Plastic Materials for Parts UL does not list any manufacturers liquidtight conduit as low smoke zero halogen Made in USA of US and/or imported materials Trade Trade Coil Approx. Reel Weight/ xternal Diameter (inches) Internal Diameter Bend Product Size Size Length Length 100 feet Over Jacket (min/max) Radius Code (inches) (mm) (feet) (feet) (pounds) (min/max) inches (inches) / ' / / / ' / / / ' / / / ' / / / ' / / / ' / / / ' / / ' / / ' / / ' / / ' / / ' / / ' / / ' / / ' / / NOT: All dimensions and weights are subject to normal manufacturing tolerances. 7

10 Industrial Low Smoke Zero Halogen LSZH UL Liquidtight Flexible Metal Conduit Type LFMC Scope This specification covers AFC Cable Systems, Inc. LIQUID-TUFF LOW SMOK ZRO HALOGN (LSZH) UL Liquidtight Flexible Metal Conduit designed for use as a raceway for power, control and communication cables in accordance with Article 350 of the National lectric Code. The product is intended for applications where limiting smoke and toxic materials of combustion are important considerations. The product is Underwriters Laboratories Inc. (UL) Listed for use at 80 C (176 F) in a dry location, 60 C (140 F) in a wet location and 70 C (158 F) in an oily location. It is also UL Listed for direct burial, outdoor use, sunlight resistance and for -40 C (-40 F) low temperatures applications. UL Listed Liquidtight Flexible Metal Conduit is manufactured and tested in accordance with Underwriters Laboratories Inc. Standard UL 360. The product carries the UL Listing Mark. Underwriters Laboratories Inc. does not list any manufacturers Liquidtight Flexible Metal Conduit as being low smoke zero halogen. Construction The LIQUID-TUFF LSZH Liquidtight Flexible Metal Conduit shall be formed from zinc coated galvanized low carbon steel strip having a uniform width and thickness. There shall be a continuous bonding strip built into the conduit core for the 3/8 through 11 4 trade sizes. The construction shall be in accordance with the UL 360 Standard. The Low Smoke Zero Halogen designation shall be based upon testing to ASTM 162 Flame Spread Index, ASTM 662 Smoke Density Generation and Bombardier SMP-800C Toxic Gas Generation. The finished LIQUID-TUFF LSZH Liquidtight Flexible Metal Conduit dimensions shall be in accordance with Table 5.1 of UL 360 which is summarized in Table 3. Jacket TPU A rugged low-smoke, moisture, oil, sunlight resistant and flame retardant thermoplastic polyurethane jacket shall be applied directly over the flexible metal conduit. The physical properties of the jacket material shall comply with the UL 360 Standard. The Low Smoke Zero Halogen jacket shall be tested to and comply with ASTM 162 Flame Spread Index, ASTM 662 Smoke Density Generation and Bombardier SMP-800C Toxic Gas Generation. The test results are summarized in Table 1. Underwriters Laboratories Inc. (UL) does not List any manufacturers jacket compound as being low smoke zero halogen. The jacket wall thickness shall be in accordance with Table 4.1 of UL 360 which is summarized in Table 2. Jacket: Black Grounding Permanent circuit ground protection is provided through the continuous bonding strip built into the conduit core in trade sizes 3/8 through A separate grounding conductor is required by the NC for all trade sizes and larger. Reference Standards UL 360 Standard for Liquidtight Flexible Steel Conduit File Reference NC Articles UL , 350, (B)(2), (A)(2), (A)(2), (A)(1)(c)(2), (A)(2)(a), (A)(2)(d)(2), (A)(3)(a), (A)(4)(2), (B)(1), (C)(1) 645.5()(2), , , 695.6() and () Department of Defense UL 360 adopted on October 1, 1987 ASTM 162 ASTM 662 Bombardier SMP-800C UL 94 Flame Spread Index Smoke Density Generation Toxic Gas Generation Tests for Flammability of Plastic Materials for Parts Markings The surface of the outer jacket shall be clearly marked with a legible print legend in compliance with the UL 360 Standard. Performance Tests In accordance with UL 360, the completed LIQUID-TUFF LSZH Liquidtight Flexible Metal Conduit shall meet all of the performance requirements outlined in Appendix A. 8

11 Industrial Low Smoke Zero Halogen LSZH UL Liquidtight Flexible Metal Conduit Type LFMC Table 1 LIQUID-TUFF LSZH Combustion and Flammability Properties PROPRTY TST RSULTS Vertical Burn (Material) UL 94 UL Listed: V-O Rating No Flaming Drips Vertical Burn (Conduit) UL 360 UL Listed: Passed Oxygen Index % (Material) ASTM D % Flame Spread Index ASTM -162 Passed No Flaming Drips Smoke Generation ASTM min (Flaming) (NFPA-258) 4.0 min No Flaming Drips Smoke Generation ASTM min (Non-flaming) (NFPA-258) 4.0 min No Flaming Drips Toxic Gas Generation Bombardier Pass SMP-800C Testing performed by independent test laboratory. Test results available upon request. Table 2 Jacket Thickness Conduit Trade Minimum Acceptable Average Trade Size Metric Designator Thickness of Jacket, (inches) 3/ / / Table 3 Conduit Diameters Acceptable Internal and xternal Diameters Conduit Size Internal Over Trade Metric Diameter, In. Jacket, In. Size, In. Designator Min. Max. Min. Max. 3/ / / Appendix A UL 360 Performance Tests Resistance and High Current Fault Current Impact Tension Crushing Pipe Stiffness Flexibility Low Temperature Flexibility Zinc Coating Vertical Flame Physical Properties Deformation Mechanical Water Absorption Moisture Penetration Sunlight Resistance Test for Secureness of Fittings Test for Durability of Ink Printing 9

12 Industrial Low Smoke Zero Halogen LSZH-VF Non-UL Liquidtight Flexible Metal Conduit Description Low smoke, zero halogen raceway Low toxicity generation characteristics Hot dipped zinc galvanized low carbon steel core xcellent temperature ratings Black thermoplastic polyurethane jacket Sunlight resistant Flame retardant TPU jacket Temperature Rating 80 C/176 F Dry 60 C/140 F Wet 70 C/158 F Oil resistant -40 C Applications Wherever limiting toxic material of combustion is needed References & Ratings Non-UL core ASTM 162 Flame Spread Index ASTM 662 Smoke Density Generation Bombardier SMP-800C Toxic Gas Generation UL 94 Tests for Flammability of Plastic Materials for Parts Made in USA of US and/or imported materials Ordering Information Product Dimensions/Bend Radius Trade Trade Coil Reel Approx. Weight/ xternal Diameter (inches) Internal Diameter Bend Product Size Size Length Length 100 feet Over Jacket (min/max) Radius Code (inches) (mm) (feet) (feet) (pounds) (min/max) inches (inches) / ' / / / ' / / / ' / / / ' / / / ' / / / ' / / / ' / / ' / / ' / / ' / / ' / / ' / / ' / / ' / / ' / / NOT: All dimensions and weights are subject to normal manufacturing tolerances. Not listed for grounding. 10

13 Industrial Low Smoke Zero Halogen LSZH-VF Non-UL Liquidtight Flexible Metal Conduit Scope This specification covers AFC Cable Systems, Inc. LIQUID-TUFF Non-UL LOW SMOK ZRO HALOGN (LSZH) Liquidtight Flexible Metal Conduit designed for use where limiting smoke and toxic materials of combustion are important considerations. The product is intended for use at 80 C (176 F) in a dry location, 60 C (140 F) in a wet location and 70 C (158 F) in an oily location. It is also acceptable for outdoor use at -40 C (-40 F) low temperatures and is sunlight resistant. This Liquidtight Flexible Metal Conduit is manufactured and tested in accordance with generally accepted industry practices. The product is designed to be used for specific applications where Underwriters Laboratories Inc. (UL) or other agency approvals are not required. Construction The LIQUID-TUFF LSZH Liquidtight Flexible Metal Conduit shall be formed from zinc coated galvanized low carbon steel strip having a uniform width and thickness. The Low Smoke Zero Halogen designation shall be based upon testing to ASTM 162 Flame Spread Index, ASTM 662 Smoke Density Generation and Bombardier SMP-800C Toxic Gas Generation. The finished LIQUID-TUFF LSZH Liquidtight Flexible Metal Conduit dimensions shall be in accordance with Table 3. Jacket TPU A rugged low-smoke, moisture, oil, sunlight resistant and flame retardant thermoplastic polyurethane jacket shall be applied directly over the flexible metal conduit. The Low Smoke Zero Halogen jacket shall be tested to and comply with ASTM 162 Flame Spread Index, ASTM 662 Smoke Density Generation and Bombardier SMP-800C Toxic Gas Generation. The test results are summarized in Table 1. In addition the jacket shall comply with Table 2 of this specification. LIQUID-TUFF LSZH-VF Reference Standards ASTM 162 Flame Spread Index ASTM 662 Bombardier SMP-800C UL 94 Smoke Density Generation Toxic Gas Generation Tests for Flammability of Plastic Materials for Parts Grounding A separate grounding conductor is required for all trade sizes. Markings The surface of the outer jacket shall be clearly marked with the applicable print legend. Performance Tests The completed LIQUID-TUFF LSZH Non-UL Liquidtight Flexible Metal Conduit shall meet all of the performance requirements outlined in Appendix A. 11

14 Industrial Low Smoke Zero Halogen LSZH-VF Non-UL Liquidtight Flexible Metal Conduit Table 1 LIQUID-TUFF LSZH-VF Combustion and Flammability Properties PROPRTY TST RSULTS Vertical Burn (Material) UL 94 UL Listed: V-O Rating No Flaming Drips Vertical Burn (Conduit) UL 360 Passed Oxygen Index % (Material) ASTM D % Flame Spread Index ASTM -162 Passed No Flaming Drips Smoke Generation ASTM min (Flaming) (NFPA-258) 4.0 min No Flaming Drips Smoke Generation ASTM min (Non-flaming) (NFPA-258) 4.0 min No Flaming Drips Toxic Gas Generation Bombardier Pass SMP-800C Testing performed by independent test laboratory. Test results available upon request. Table 3 Conduit Diameters Acceptable Internal and xternal Diameters Conduit Size Internal Over Trade Metric Diameter, In. Jacket, In. Size, In. Designator Min. Max. Min. Max. 3/ / / Table 2 Jacket Thickness Conduit Trade Minimum Acceptable Average Trade Size Metric Designator Thickness of Jacket, (inches) 3/ / / Appendix A Performance Tests Flexibility Low Temperature Flexibility Zinc Coating Vertical Flame Physical Properties Deformation Mechanical Water Absorption Moisture Penetration Sunlight Resistance Test for Durability of Ink Printing 12

15 Industrial Non-UL Oil Resistant/High Temperature Liquidtight Flexible Steel Conduit Description High-quality PVC jacket for oil resistance and high temperatures Grey Hot dipped zinc galvanized low carbon steel core xcellent flexibility Non-UL liquidtight electrical raceway Temperature Rating 105 C/221 F Dry 60 C/140 F Wet 70 C/158 F Oil resistant -26 C Applications Oily and harsh chemical environments UV resistant xcellent flexibility Industrial applications Indoor or outdoor locations Provides mechanical protection for conductors References & Ratings Non-UL Separate grounding conductor required in all sizes Made in USA of US and/or imported materials Ordering Information Product Dimensions/Bend Radius Trade Trade Coil Reel Approx. Weight/ xternal Diameter (inches) Internal Diameter Bend Product Size Size Length Length 100 feet Over Jacket (min/max) Radius Code (inches) (mm) (feet) (feet) (pounds) (min/max) inches (inches) / ' / / / ' / / / ' / / / ' / / / ' / / / ' / / / ' / / / ' / / / ' / / ' / / ' / / ' / / ' / / ' / / ' / / ' / / ' / / ' / / ' / / NOT: All dimensions and weights are subject to normal manufacturing tolerances. Not for grounding. 13

16 Industrial Non-UL Oil Resistant/High Temperature Liquidtight Flexible Steel Conduit Scope This specification covers AFC Cable Systems, Inc. LIQUID-TUFF Non- UL Oil Resistant/High Temperature Liquidtight Flexible Steel Conduit designed for use in high temperature oily applications. The product is intended for use at 105 C (221 F) in a dry location, 60 C (140 F) in a wet location, 70 C (158 F) in an oily location and at -26 C (-15 F) in a low temperature application. The product is rated for outdoor and sunlight resistant use in dark colors. The product is designed to be used for specific applications where Underwriters Laboratories Inc. (UL) or other agency approvals are not required. Construction Non-UL Oil Resistant/High Temperature Liquidtight Flexible Steel Conduit shall be formed from a zinc coated galvanized low carbon steel strip having a uniform width and thickness. The convolutions of the interlock shall be filed with a fibrous material designed to promote flexibility. Jacket PVC A rugged moisture, oil and sunlight resistant polyvinyl chloride (PVC) jacket shall be applied directly over the flexible metal conduit with a wall thickness in accordance with Table 2. Jacket: Grey Grounding A separate grounding conductor is required for all trade sizes. Markings The surface of the outer jacket shall be clearly marked with the applicable legible print legend. Performance Tests The completed LIQUID-TUFF Non-UL Oil Resistant/High Temperature Liquidtight Flexible Steel Conduit shall meet all of the performance requirements outlined in Appendix A. Table 3 Conduit Diameters Acceptable Internal and xternal Diameters Conduit Size Internal Over Trade Metric Diameter, In. Jacket, In. Size, In. Designator Min. Max. Min. Max. 3/ / / Table 2 Jacket Thickness LIQUID-TUFF Oil Res/High Temp Conduit Trade Minimum Acceptable Average Trade Size Metric Designator Thickness of Jacket, (inches) 3/ / / The finished product dimensions shall be in accordance with Table 3. Appendix A Performance Tests Flexibility Low Temperature Flexibility Zinc Coating Vertical Flame Physical Properties Mechanical Water Absorption Moisture Penetration Sunlight Resistance 14

17 Industrial Non-UL xtreme Temperature Liquidtight Flexible Metal Conduit Description High quality thermoplastic rubber jacket Black Ability to withstand extremes in temperature Hot dipped zinc galvanized low carbon steel core Halogen free Oil and ozone resistant Superior flexibility Temperature Rating 150 C/302 F Dry Intermittent use 135 C/275 F Dry Continuous use 60 C Oily and wet -60 C/-76 F Low temperature brittle point Applications Resists extremes in temperature Very high operating temperatures For location requiring halogen free conduits Industrial applications Indoor or outdoor locations Provides mechanical protection for conductors References & Ratings Non-UL Meets UL 94HB flammability requirements Meets ASTM D746 low temperature brittle point -60 /-76 F Separate grounding conductor is required for all trade sizes Made in USA of US and/or imported materials Ordering Information Product Dimensions/Bend Radius Trade Trade Coil Reel Approx. Weight/ xternal Diameter (inches) Internal Diameter Bend Product Size Size Length Length 100 feet Over Jacket (min/max) Radius Code (inches) (mm) (feet) (feet) (pounds) (min/max) inches (inches) / ' / / / ' / / / ' / / / ' / / / ' / / / ' / / / ' / / ' / / ' / / ' / / ' / / ' / / ' / / ' / / ' / / ' / / ' / / NOT: All dimensions and weights are subject to normal manufacturing tolerances. Not for grounding. 915

18 Industrial Non-UL xtreme Temperature Liquidtight Flexible Metal Conduit Scope This specification covers AFC Cable Systems, Inc. LIQUID-TUFF Non-UL TRM TMPRATUR Liquidtight, Flexible Metal Conduit designed for use where operation at a high temperature is required. The product is appropriate for intermittent use at 150 C (302 F) and continuous use at 135 C (275 F) in a dry location, 60 C in a wet location or 60 C in an oily location. The LIQUID-TUFF TRM TMPRATUR jacket material is halogen-free, meets UL 94HB flammability requirements and has a low temperature brittle point of -60 C (-76 F). The product is designed to be used for specific applications where Underwriters Laboratories Inc. (UL) or other agency approvals are not required. Construction The Non-UL TRM TMPRATUR Liquidtight, Flexible Steel Conduit core shall be formed into a very flexible interlocked steel conduit from a zinc coated galvanized low carbon steel strip having a uniform width and thickness. The convolutions of the interlock shall be filed with a fibrous material designed to promote flexibility. Jacket TPR A rugged moisture, oil and ozone resistant thermoplastic elastomer jacket shall be extruded directly over the interlocked very flexible steel core. The jacket is halogen free, has a UL 94HB Flammability Rating and has a -60 C (-76 F) Low Temperature Brittle Point when tested in accordance with ASTM D-746. The wall thickness is in conformance with Table 1. Jacket: Black 720-Hour enon-arc sunlight/weather resistance - ASTM D2565 and ASTM G155. Grounding A separate grounding conductor is required for all trade sizes. Markings The outer surface of the jacket shall be clearly marked with the applicable print legend. Performance Tests The completed LIQUID-TUFF Non-UL TRM TMPRATUR Liquidtight Flexible Steel Conduit shall meet all of the applicable performance requirements. Table 1 Jacket Thickness LIQUID-TUFF TRM TMP Conduit Trade Minimum Acceptable Average Trade Size Metric Designator Thickness of Jacket, (inches) 3/ / /

19 Industrial UL Liquidtight Flexible Non-Metallic Conduit Type A Orange Type LFNC-A Description Layered Type A construction per NC 356.2(1) Nylon reinforced braid between two layers of PVC for strength and flexibility Flame retardant compound Sunlight resistant Oil resistant Mild acid resistance Non-conductive raceway Temperature Rating 80 C/176 F Dry 60 C/140 F Wet 60 C/140 F Oil resistant Applications Constant flexing and motion applications For Neon Secondary-Circuit Wiring, 1000V or Less per NC (A) For Neon Secondary-Circuit Wiring, over 1000V per NC (A)(1) Hazardous locations where Flexible Connections are required per NC (B)(2)(3), (A)(2)(2), (B)(2)(2), (A)(3)(2), (B), Cranes and Hoists per NC (C) Information Technology quipment per NC 645.5()(2) For Swimming Pools, Fountains, and Similar Installations NC (A)(3) For Natural and Artificially Made Bodies of Water NC For Solar Photovoltaic (PV) Systems per NC (A) Industrial and commercial applications Physical protection from abrasion of the conductors inside Indoor or outdoor locations References & Ratings UL NC 356, , (B)(2)(4), (A)(2)(3), (B)(1)(1), (B)(2), (A)(3)(3) (B), , 553.7(B), (A), (A)(1), (C), (A)(1)(c)(3), (A)(2)(a), (A)(2)(d)(3), (A)(3)(a), (A(4)(4), (B)(1), (C)(1), 645.5()(2), (A)(3), (b)(2), (f)(1), (a)(1)(1), (a)(1), , (A) CSA C22.2 No File LL69271 Made in USA of US and/or imported materials Ordering Information Product Dimensions/ Bend Radius Approx. Internal xternal Trade Trade Coil Reel Weight/ Diameter Diameter Bend Product Size Size Length Length 100 feet Wall (min/max) (min/max) Radius Code (inches) (mm) (feet) (feet) (pounds) Thickness inches inches (inches) / ' / / / ' / / / ' / / / ' / / ' / / ' / / ' / / ' / / ' / / NOT: All dimensions and weights are subject to normal manufacturing tolerances

20 Industrial UL Liquidtight Flexible Non-Metallic Conduit Type A Orange Type LFNC-A Scope This specification covers AFC Cable Systems, Inc. LIQUID-TUFF Layered Liquidtight Flexible Non-Metallic Conduit, designed for use in wet, dry or oily locations as a flame resistant, Non-Metallic raceway for power, control and communications cables where repetitive motion and constant flexing is required. It is intended for applications where abrasion and physical abuse may occur. It complies with Article 356 of the NC regarding layered conduit Type LFNC-A. The product is UL Listed for 80 C (176 F) in a dry location, 60 C (140 F) in a wet location and 60 C (140 F) in a oily location. It is also UL Listed through 2-inch trade sizes for outdoor use and sunlight resistance. This Liquidtight Flexible Non-Metallic Conduit is manufactured and tested in accordance with Harmonized Underwriters Laboratories Inc. Standard UL The product carries the UL Listing Mark, CSA Certification, and CSA Harmonized Certification. Construction Liquidtight Flexible Non-Metallic Conduit Type LFNC-A is a layered raceway of circular cross section with a smooth flexibly polyvinyl chloride (PVC) inner layer with a reinforcing layer covered with a flexible polyvinyl chloride (PVC) jacket. The wall thicknesses and dimensions of the layered conduit shall comply with Table1 of harmonized UL 1660/CSA C22.2 No of UL 1660 which is summarized in Table 1. Color: Orange Grounding A separate Grounding conductor is required by both the National lectrical Code and Canadian lectrical Code for all trade sizes. Markings The outer surface of the conduit shall be clearly marked with a legible print legend in accordance with harmonized UL 1660/CSA C22.2 No Performance Tests The completed LIQUID-TUFF Liquidtight Flexible Non-Metallic Conduit Type A shall meet all of the performance requirements contained in UL 1660 outlined in Appendix A. LIQUID-TUFF - TYP LFNC - A Reference Standards UL 1660/ CSA C22.2 No Standard for Liquidtight Flexible Non-Metallic Conduit File References UL , CSA NC Articles: Appendix A NC 356, , (B)(2)(4), (A)(2)(3), (B)(1)(1), (B)(2), (A)(3)(3), (B), , 553.7(B), (A), (A)(1), (C), (A)(1)(c)(3), (A)(2)(a), (A)(2)(d)(3), (A)(3)(a), (A(4)(4), (B)(1), (C)(1), 645.5()(2), (A)(3), (b)(2), (f)(1), (a)(1)(1), (a)(1), , (A) Table 1 Conduit Size Inside Outside Min. Min. Wall Trade Diameter, In. Diameter, In. Bend Weight Thickness Size, In. Metric Min. Max. Min. Max. Radii, In. lbs/100ft Inches 3/8 (12) /2 (16) /4 (21) (27) (35) (41) (53) UL Performance Tests Physical Properties Original Tensile and longation Air Oven Aging Test Oil Immersion Test Deformation Tension Flexibility (Room and Low Temperature) Vertical Flame Room Temperature Impact Secureness of Fittings Mechanical Water Absorption Moisture Penetration Test Durability of Ink Sunlight Resistance Crush Test 18

21 Industrial UL Liquidtight Flexible Steel Conduit, Type LFMC NSF 169 Component for Splash Zones Description NSF 169 Component for splash zones in food production areas NSF 169 Special Purpose Food quipment and Devices PVC jacket inhibits bacteria growth color white ase of cleaning/sterilization using bleach no degradation of jacket Flexible rugged moisture, oil & sunlight resistant PVC jacket Hot dipped zinc galvanized low carbon steel core xcellent temperature range UL bonding strip 3/8 1 ¼ for grounding Temperature Rating 80 C/176 F Dry 60 C/140 F Wet 70 C/158 F Oily -30 C/-22F Low temperature Applications Food equipment & other devices associated with food production NSF 169 compliant For use in splash zones contiguous to food production wash down areas PVC jacket does not promote the growth of bacteria Meat packing, restaurants, food processing, poultry packing, pharmaceutical facilities References & Ratings UL 360 File NSF 169 NC 250, 350, 390, (B)(2)(3), (A)(2)(2), (B)(2)(2), (A)(3)(2), (B), , 553.7(B), (A), (A)(1), (C), (A)(1)(c)(2), (A)(2)(a), (A)(2)(d)(2), (A)(3)(a), (A)(4)(2), (B)(1), (C)(1), 645.5()(2), (A)(1), , (A), 695.6(D), () Ordering Information Product Dimensions/Bend Radius Trade Trade Coil Approx. Weight/ xternal Diameter (inches) Internal Diameter Bend Product Size Size Length 100 feet Over Conduit Over Jacket (min/max) Radius Code (inches) (mm) (feet) (pounds) (min/max) (min/max) inches (inches) SZ / / / / SZ / / / / SZ / / / / SZ / / / SZ / / / / SZ / / / / SZ / / / NOT: All dimensions and weights are subject to normal manufacturing tolerances. Review NC and (6) for grounding requirements. 19

22 Industrial UL Liquidtight Flexible Steel Conduit, Type LFMC NSF 169 Component for Splash Zones Scope This specification covers AFC Cable Systems, Inc. UL Liquid-Tuff Liquidtight Flexible Steel Conduit designed for use as a raceway for NSF 169 Special Purpose Food quipment and Devices, meat packing, restaurants, food processing, poultry packing, pharmaceutical facilities, as well as, power, control and communications cables in accordance with Article 350 of the National lectrical Code. Temperature ranges: 80 C/176 F Dry, 60 C/140 F Wet, 70 C/158 F Oily, -30 C/-22F Low temperature. PVC jacket designed to inhibit bacteria growth and to withstand wash down/splash zones with bleach agents. This Liquidtight Flexible Steel Conduit is manufactured and tested in accordance with Underwriters Laboratories Inc. Standard UL 360 and carries the UL Listing Mark. It is further certified to NSF 169, CSA C22.2 Number 56. The product carries the UL Listing Mark, CSA Certification Mark, and NSF 169 Certification Logo. Construction The Type UL Liquidtight Flexible Steel Conduit shall be formed from a zinc coated galvanized low carbon steel strip having a uniform width and thickness. The construction shall be in accordance with UL 360 and NSF 169. The finished Type LFMC dimensions shall be in accordance with Table 5.1 of UL 360. Jacket PVC White* PVC jacket inhibits bacteria growth. Rugged moisture, oil and sunlight resistant polyvinyl chloride (PVC) jacket shall be applied directly over the flexible metal conduit with a wall thickness in accordance with Tabe 4.1 of UL 360. May be cleaned without degradation to the jacket with bleaching agents. Jacket Color: Stocked in white *Also available in Gray, Black, Red, Orange, Yellow, Green or Blue References & Ratings UL 360 File NSF 169 NC 250, 350, 390, (B)(2)(3), (A)(2)(2), (B)(2)(2), (A)(3)(2), (B), , 553.7(B), (A), (A)(1), (C), (A)(1)(c)(2), (A)(2)(a), (A)(2)(d)(2), (A)(3)(a), (A)(4)(2), (B)(1), (C)(1), 645.5()(2), (A)(1), , (A), 695.6(D), () *By special request: gray, black, red, orange, yellow, green or blue Reference Standards UL 360 Standard for Liquidtight Flexible Steel Conduit CSA C22.2 No. 56 Standard for Flexible Metal Conduit and Liquidtight Flexible Metal Conduit File Reference(s): UL 26540; CSA NC Articles: NC 250, 350, 390, (B)(2)(3), (A)(2)(2), (B)(2)(2), (A)(3)(2), (B), , 553.7(B), (A), (A)(1), (C), (A)(1)(c)(2), (A)(2)(a), (A)(2)(d)(2), (A)(3)(a), (A)(4)(2), (B)(1), (C)(1), 645.5()(2), (A)(1), , (A), 695.6(D), () Department of Defense Adopted UL 360 on October 1, 1987 NSF/ANSI 169 Special Purpose Food quipment and Devices Markings The surface of the outer jacket shall be clearly marked with a legible print legend in compliance with UL 360, CSA C22.2 No. 56 and NSF 169. Performance Tests In accordance with UL 360 and CSA C 22.2 No. 56, the completed UL Liquid-Tuff Liquidtight Flexible Conduit shall meet all of the performance requirements outlined in Appendix A for Type LFMC on page

23 Commercial Commercial Liquidtight Flexible Conduit Commercial Liquidtight Flexible Conduit UL Type LFMC UL Computer Blue Type LFMC Non-UL VF Type LFNC-B Ultraflex Liquidtight HYDROTIT Type COM-BLU CSA Flexible Conduit HYDROTIT Type CSA CSA Flexible Conduit

24 Commercial UL Liquidtight Flexible Steel Conduit, Type LFMC (Grey, Black, Red, Orange, Yellow, Green) Description UL bonded strip 3/8" 1 1 4" for grounding UL Liquidtight all sizes Sunlight resistant Flame retardant PVC jacket Hot dipped zinc galvanized low carbon steel core Available in Grey, Black, Red, Orange, Yellow or Green Temperature Rating 80 C/176 F to -30 C/-22 F Dry 60 C/140 F Wet 70 C/158 F Oil resistant Applications 600 volt and lower circuits Direct burial in earth Concrete embedment Sunlight and weather exposure Suitable for grounding per NC (6), 3/8" 1 1 4" Hazardous location per NC (B)(2)(4), (A)(2)(3), (B)(1)(1), (B)(2), (A)(3)(3), (B), Raised computer room floors per NC 645.5()(2) Service entrance wiring up to 6 feet per NC (15) Feeders and services for marina and boat yards Ordering Information References & Ratings UL 360, File Reference 26540, CSA Certified File LL51593, CSA C22.2 Number 56 NC 250, 350, 390, (B)(2)(3), (A)(2)(2), (B)(2)(2) (A)(3)(2), (B), , 553.7(B), (A), (A)(1), (C), (A)(1)(c)(2), (A)(2)(a), (A)(2)(d)(2), (A)(3)(a), (A)(3)(a), (A)(4)(2), (B)(1), (C)(1), 645.5()(2), (A)(1), , (A), 695.6(D) and () Canadian lectrical Code (CC) Part I Clause UL approved for use in direct burial applications including concrete and earth burial (Sizes 3/8" through 4") Conduit in sizes 1 1 2" and larger requires grounding conductor per NC May be installed under raised computer room floors per NC 645.5()(2) Made in USA of US and/or imported materials Product Dimensions/Bend Radius Product Trade Trade Coil Reel Approx. Weight/ xternal Diameter (inches) Internal Diameter Bend Code Size Size Length Length 100 feet Over Jacket (min/max) Radius Black (inches) (mm) (feet) (feet) (pounds) (min/max) inches (inches) BK 3/ ' / / BK 1/ ' / / BK 1/ ' / / BK 1/ ' / / BK 3/ ' / / BK 3/ ' / / BK 3/ ' / / BK ' / / BK ' / / BK ' / / BK ' / / BK ' / / BK ' / / BK ' / / NOT: All dimensions and weights are subject to normal manufacturing tolerances. Review NC and (6) for grounding requirements, conduit sizes 1 1 2" and larger. Minimum order quantity required. For more colors and sizes see the next page. 22

25 Commercial UL Liquidtight Flexible Steel Conduit, Type LFMC (Grey, Black, Red, Orange, Yellow, Green) Ordering Information Product Dimensions/Bend Radius Product Trade Trade Coil Reel Approx. Weight/ xternal Diameter (inches) Internal Diameter Bend Code Size Size Length Length 100 feet Over Conduit Over Jacket (min/max) Radius Gray (inches) (mm) (feet) (feet) (pounds) (min/max) (min/max) inches (inches) / ' / / / / ' / / / / ' / / / / ' / / / / ' / / / / ' / / / / ' / / / / ' / / / / ' / / / / ' / / / / ' / / / / ' / / / ' / / / ' / / / ' / / / ' / / / ' / / / ' / / / ' / / / ' / / / ' / / / ' / / / ' / / / ' / / / ' / / / ' / / / ' / / / ' / / / ' / / / ' / / / ' / / / ' / / / RD * RD 1/ ' / / / RD 1/ ' / / / RD 3/ ' / / / RD 3/ ' * / / / ORANG * O 1/ ' / / / O 1/ ' / / / O 3/ ' / / / O 3/ ' * / / / YLLOW * YW 1/ ' / / / YW 1/ ' / / / YW 3/ ' / / / YW 3/ ' * / / / GRN * GN 1/ ' / / / GN 1/ ' / / / GN 3/ ' / / / GN 3/ ' * / / / NOT: All dimensions and weights are subject to normal manufacturing tolerances. Made in USA of US and/or imported materials Review NC and (6) for grounding requirements. * 3 4 available on 1000 Reels, call for details 23 19

26 Commercial UL Liquidtight Flexible Steel Conduit, Type LFMC Scope This specification covers AFC Cable Systems, Inc. UL LIQUID-TUFF Liquidtight Flexible Steel Conduit designed for use as a raceway for power, control and communication cables in accordance with Article 350 of the National lectrical Code. The product is Underwriters Laboratories Inc. (UL) Listed for 80 C (176 F) in a dry location, 60 C (140 F) in a wet location and 70 C (158 F) in an oily location. It is also UL Listed in all trade sizes for direct burial in either earth or concrete encasement, outdoor use and sunlight resistance. This LIQUID-TUFF is now UL Listed for 70 C OIL RSISTANT applications. In addition the product is CSA certified for use at 75 C (167 F) in dry and oily locations and for minus 25 C (-13 F) low temperature applications. This Liquidtight Flexible Steel Conduit is manufactured and tested in accordance with Underwriters Laboratories Inc. Standard UL 360 and CSA International Standard CSA C22.2 Number 56. The product carries the UL Listing Mark and the CSA Certification Mark. Construction The Type UL Liquidtight Flexible Steel Conduit shall be formed from a zinc coated galvanized low carbon steel strip having a uniform width and thickness. The construction shall be in accordance with UL 360 and CSA C22.2 Number 56 requirements. The finished Type LFMC dimensions shall be in accordance with Table 5.1 of UL 360 and Table 2 of CSA C22.2 No. 56 which are summarized in Table 3. Jacket PVC A rugged moisture, oil and sunlight resistant polyvinyl chloride (PVC) jacket shall be applied directly over the flexible metal conduit with a wall thickness in accordance with Table 4.1 of UL 360 and Table 4 of CSA C22.2 No.56 which are summarized in Table 2. Jacket Color: Gray, Black, Red, Orange, Yellow, or Green Grounding Permanent circuit ground protection is provided through the continuous bonding strip built into the conduit core in sizes 3/8" through 1 1 4". A separate grounding conductor is required by the NC for trade sizes 1 1 2" and larger. The Canadian lectric Code requires a grounding conductor for all trade sizes of Liquidtight Flexible Metal Conduit. Reference Standards UL 360 Standard for Liquidtight Flexible Steel Conduit CSA C22.2 No. 56 Standard for Flexible Metal Conduit and Liquidtight Flexible Metal Conduit File Reference(s): UL 26540; CSA NC Articles: LIQUID-TUFF LFMC- UL NC (6), , , (B)(2), (A)(2), (A)(2), 511.7(A)(1), 645.5(D)(2), , , 695.6() and () Department of Defense Adopted UL 360 on October 1, 1987 Markings The surface of the outer jacket shall be clearly marked with a legible print legend in compliance with UL 360, and CSA C22.2 No. 56. Performance Tests In accordance with UL 360 and CSA C22.2 No. 56, the completed UL Liquidtight Flexible Steel Conduit shall meet all of the performance requirements outlined in Appendix A. 24

27 Commercial UL Liquidtight Flexible Steel Conduit, Type LFMC Table 2 Jacket Thickness Conduit Trade Minimum Acceptable Average Trade Size Metric Designator Thickness of Jacket, (inches) 3/ / / Appendix A UL Performance Tests Resistance and High Current Fault Current Impact Tension Crushing Pipe Stiffness Flexibility Zinc Coating Vertical Flame Physical Properties Deformation Mechanical Water Absorption Moisture Penetration Sunlight Resistance Test for Secureness of Fittings Test for Durability of Ink Printing CSA Performance Tests Physical Properties Original Tensile and longation Air Oven Aging Test Oil Immersion Test Deformation Test Tension Zinc Coating Low Temperature Flexibility Vertical Flame Cold Impact Pinhole Test Compatibility with Connectors Table 3 Conduit Diameters Acceptable Internal and xternal Diameters Conduit Size Internal Over Over Trade Metric Diameter, In. Conduit, In. Jacket, In. Size, In. Designator Min. Max. Min. Max. Min. Max. 3/ / /

28 Commercial Description Computer Blue UL Liquidtight Flexible Metal Conduit, Type LFMC UL bonded strip 3/8" 1 1 4" for grounding UL Liquidtight all sizes Sunlight resistant Flame retardant PVC jacket Hot dipped zinc galvanized low carbon steel core Blue PVC jacket Temperature Rating 80 C to -30 C Dry 60 C Wet 70 C Oil resistant Applications Raised computer room floors per NC 645.5()(2) Direct burial in earth Concrete embedment Suitable for grounding per NC (6), 3/8" 1 1 4" Hazardous location per NC 501 Ordering Information References & Ratings UL 360, File Reference CSA LL51593, CSA C22.2 Number 56 NC 250, 350, 390, (B)(2)(3), (A)(2)(2), (B)(2)(2) (A)(3)(2), (B), , 553.7(B), (A), (A)(1), (C), (A)(1)(c)(2), (A)(2)(a), (A)(2)(d)(2), (A)(3)(a), (A)(3)(a), (A)(4)(2), (B)(1), (C)(1), 645.5()(2), (A)(1), , (A), 695.6(D) and () Canadian lectrical Code (CC) Part I Clause UL bonding strip 3/8 fit 1 1 4" for grounding UL approved for use in direct burial applications including concrete and earth burial (Sizes 3/8" through 4") Conduit in sizes 1 1 2" and larger requires grounding conductor per NC Made in USA of US and/or imported materials Product Dimensions/Bend Radius Trade Trade Coil Reel Approx. Weight/ xternal Diameter (inches) Internal Diameter Bend Product Size Size Length Length 100 feet Over Jacket (min/max) Radius Code (inches) (mm) (feet) (feet) (pounds) (min/max) inches (inches) / ' / / / ' / / / ' / / / ' / / / ' / / / ' / / ' / / ' / / ' / / ' / / ' / / / / ' / / ' / / ' / / ' / / ' / / ' / / NOT: All dimensions and weights are subject to normal manufacturing tolerances. Review NC and (6) for grounding requirements. 26

29 Commercial Computer Blue UL Liquidtight Flexible Metal Conduit, Type LFMC Scope This specification covers AFC Cable Systems, Inc. UL LIQUID-TUFF Computer Blue Liquidtight Flexible Steel Conduit designed for use as a raceway for power, control and communication cables in accordance with Article 350 of the National lectrical Code. The product is Underwriters Laboratories Inc. (UL) Listed for 80 C (176 F) in a dry location, 60 C (140 F) in a wet location and 70 C (158 F) in an oily location. It is also UL Listed in all trade sizes for direct burial in either earth or concrete encasement, outdoor use and sunlight resistance. This LIQUID-TUFF is now UL Listed for 70 C OIL RSISTANT applications. In addition the product is CSA certified for use at 75 C (167 F) in dry and oily locations and for minus 25 C (-13 F) low temperature applications. This Liquidtight Flexible Steel Conduit is manufactured and tested in accordance with Underwriters Laboratories Inc. Standard UL 360 and CSA International Standard CSA C22.2 Number 56. The product carries the UL Listing Mark and the CSA Certification Mark. Construction The Type UL Liquidtight Flexible Steel Conduit shall be formed from a zinc coated galvanized low carbon steel strip having a uniform width and thickness. The construction shall be in accordance with UL 360 and CSA C22.2 Number 56 requirements. The finished Type LFMC dimensions shall be in accordance with Table 5.1 of UL 360 and Table 2 of CSA C22.2 No. 56 which are summarized in Table 3. Jacket PVC A rugged moisture, oil and sunlight resistant polyvinyl chloride (PVC-colored Blue) jacket shall be applied directly over the flexible metal conduit with a wall thickness in accordance with Table 4.1 of UL 360 and Table 4 of CSA C22.2 No.56 which are summarized in Table 2. Jacket: Blue Grounding Permanent circuit ground protection is provided through the continuous bonding strip built into the conduit core in sizes 3/8" through 1 1 4". A separate grounding conductor is required by the NC for trade sizes 1 1 2" and larger. The Canadian lectric Code requires a grounding conductor for all trade sizes of Liquidtight Flexible Metal Computer Blue Conduit. LIQUID-TUFF LFMC-UL Reference Standards UL 360 Standard for Liquidtight Flexible Steel Conduit CSA C22.2 No. 56 Standard for Flexible Metal Conduit and Liquidtight Flexible Metal Computer Blue Conduit File Reference(s): UL 26540; CSA NC Articles: (6), , , (B)(2), (A)(2), (A)(2), 511.7(A)(1), (A)(d), 645.5(D)(2), , , 695.6() and () Department of Defense Adopted UL 360 on October 1, 1987 Markings The surface of the outer jacket shall be clearly marked with a legible print legend in compliance with UL 360 and CSA C22.2 No. 56. Performance Tests In accordance with UL 360 and CSA C22.2 No. 56, the completed UL LIQUID-TUFF Computer Blue Liquidtight Flexible Steel Conduit shall meet all of the performance requirements outlined in Appendix A

30 Commercial Computer Blue UL Liquidtight Flexible Metal Conduit, Type LFMC Table 2 Jacket Thickness Conduit Trade Minimum Acceptable Average Trade Size Metric Designator Thickness of Jacket, (inches) 3/ / / Appendix A UL Performance Tests Resistance and High Current Fault Current Impact Tension Crushing Pipe Stiffness Flexibility Zinc Coating Vertical Flame Physical Properties Deformation Mechanical Water Absorption Moisture Penetration Sunlight Resistance Test for Secureness of Fittings Test for Durability of Ink Printing CSA Performance Tests Physical Properties Original Tensile and longation Air Oven Aging Test Oil Immersion Test Deformation Test Tension Zinc Coating Low Temperature Flexibility Vertical Flame Cold Impact Pinhole Test Compatibility with Connectors Table 3 Conduit Diameters Acceptable Internal and xternal Diameters Conduit Size Internal Over Over Trade Metric Diameter, In. Conduit, In. Jacket, In. Size, In. Designator Min. Max. Min. Max. Min. Max. 3/ / /

31 Commercial Non-UL Liquidtight VF Flexible Steel Conduit Description Mechanical and moisture protection for conductors Sunlight resistant Flame retardant PVC jacket Grey Hot dipped zinc galvanized low carbon steel core Very flexible Temperature Rating 60 C to -20 C Dry 60 C Wet 60 C Oil resistant Applications 600 volt and lower circuits Vibration and movement absorbing Made in USA of US and/or imported materials Ordering Information Product Dimensions/Bend Radius Trade Trade Coil Reel Approx. Weight/ xternal Diameter (inches) Internal Diameter Bend Product Size Size Length Length 100 feet Over Jacket (min/max) Radius Code (inches) (mm) (feet) (feet) (pounds) (min/max) inches (inches) / ' / / / ' / / / ' / / / ' / / / ' / / / ' / / / ' / / / ' / / / ' / / / ' / / / ' / / / ' / / ' / / ' / / ' / / ' / / ' / / ' / / ' / / ' / / ' / / ' / / ' / / ' / / ' / / ' / / ' / / ' / / ' / / ' / / ' / / NOT: All dimensions and weights are subject to normal manufacturing tolerances. Not for grounding

32 Commercial Non-UL Liquidtight Flexible Steel Conduit, Type LFMC-VF Scope This specification covers AFC Cable Systems, Inc. LIQUID-TUFF Liquidtight, Flexible Steel Conduit, Type VF designed for use in specific applications where the product is designed to be used for specific applications where Underwriters Laboratories Inc. (UL) or other agency approvals are not required flexibility is required. The product is appropriate for use at 60 C (140 F) in a dry location, 60 C in a wet location or 60 C in an oily location. SUNLIGHT RSISTANT in all trade sizes. The product is JIC and has no agency listing or certification. Construction The LIQUID-TUFF Liquidtight, Flexible Steel Conduit, Type VF core shall be formed into an interlocked steel conduit from a zinc coated galvanized low carbon steel strip having a uniform width and thickness. The convolutions of the interlock shall be filed with a fibrous material designed to promote flexibility. Jacket PVC A rugged moisture, oil and sunlight resistant polyvinyl chloride (PVC) jacket shall be extruded directly over the interlocked flexible steel core with a wall thickness in conformance with Table 1 below. Jacket: Grey Markings LIQUID-TUFF TYP VF The outer surface of the jacket shall be clearly marked with the applicable print legend. Performance Tests The completed LIQUID-TUFF Liquidtight, Flexible Steel Conduit, Type VF shall meet all of the performance requirements prescribed by applicable manufacturing standards. Table 1 Conduit Size Minimum Acceptable Average Trade Size Metric Designator Thickness of Jacket, (inches) 3/ / /

33 Commercial UL Liquidtight Flexible Non-Metallic Conduit Type LFNC-B Description UL Listed and CSA certified Rugged Non-Metallic PVC Interior integral reinforced member within conduit wall Integral Type B construction per NC 356.2(2) Rigid PVC spiral core for strength Outdoor applications including direct burial Rated for concrete embedment Sunlight and oil resistant Non-conductive raceway Temperature Rating 80 C Dry 60 C Wet 70 C Oil resistant 20 C After installation Applications 3/8" through 2" rated for direct burial and poured concrete Hazardous locations where Flexible Connections are required per NC (B)(2)(4), (A)(2)(3), (B)(1)(1), (B)(2), (A)(3)(3), (B), Industrial and commercial applications Indoor or outdoor locations Suitable for pool and spa use Air conditioning and HVAC units References & Ratings UL 1660, UL File CSA C 22.2 No CSA File NC 356, , (B)(2), (A)(2), (A)(2), 511.7(A)(1), , , , , , , 695.6(), and () Made in USA of US and/or imported materials Ordering Information Product Dimensions/ Bend Radius Approx. Internal xternal Trade Trade Coil Reel Weight/ Diameter Diameter Bend Product Size Size Length Length 100 feet (min/max) (min/max) Radius Code (inches) (mm) (feet) (feet) (pounds) inches inches (inches) / ' / / / ' / / / ' / / / ' / / / ' / / / ' / / ' / / ' / / ' / / ' / / ' / / NOT: All dimensions and weights are subject to normal manufacturing tolerances

34 Commercial UL Liquidtight Flexible Non-Metallic Conduit Type LFNC-B Scope This specification covers AFC Cable Systems, Inc. UL LIQUID-TUFF Integral Liquidtight Flexible Non-Metallic Conduit, Type LFNC-B designed for use in wet, dry or oily locations as a flame resistant, Non-Metallic raceway for power, control and communications cables in compliance with Article 356 of the National lectrical Code. The product is UL Listed for 80 C (176 F) in a dry location, 60 C (140 F) in a wet location and 70 C (158 F) in an oily location. It is also UL Listed through 2-inch trade sizes for direct burial, outdoor use and sunlight resistance. In addition the product is CSA certified for use at 75 C (167 F) in dry and oily locations and for minus 18 C (0 F) low temperature applications. This Liquidtight Flexible harmonized Non-Metallic Conduit is manufactured and tested in accordance with Underwriters Laboratories Inc. Standard UL 1660 and CSA International Standard CSA C22.2 Number The product carries the UL Listing Mark and the CSA Certification Mark. Construction Liquidtight Flexible Non-Metallic Conduit, Type LFNC-B is a raceway of circular cross section with a smooth polyvinyl chloride (PVC) inner surface and an integral reinforcing member within the conduit wall. The wall thicknesses and dimensions of the integral conduit shall comply with table 3 of harmonized UL 1660/CSA No which are summarized in Table 1. Grounding A separate Grounding conductor is required by both the National lectrical Code and the Canadian lectrical Code for all trade sizes. LIQUID-TUFF - TYP LFNC - B Reference Standards UL 1660 Standard for Liquidtight Flexible Non-Metallic Conduit CSA C22.2 No Standard for Flexible Liquidtight Non-Metallic Conduit File References UL File ; CSA NC Articles: 356, , (B)(2), (A)(2), (A)(2), 511.7(A)(1), , 645.5(D)(2), , , , , , 695.6() and () Markings The outer surface of the conduit shall be clearly marked with a legible print legend in accordance with UL 1660 and CSA C22.2 No Performance Tests The completed UL LIQUID-TUFF Liquidtight Flexible Non-Metallic Conduit, Type LFNC-B shall meet all of the performance requirements contained in UL 1660 and CSA C22.2 No and outlined in Appendix A. 32

35 Commercial UL Liquidtight Flexible Non-Metallic Conduit Type LFNC-B Table 1 Conduit Size Inside Outside Min. Trade Diameter, In. Diameter, In. Bend Weight Size, In. Metric Min. Max. Min. Max. Radii, In. lbs/100ft 3/8 (12) /2 (16) /4 (21) (27) (35) (41) (53) * Package lengths in excess of 100 feet contain splices; these splices must be cut out before use. Appendix A UL Performance Tests Physical Properties Original Tensile and longation Air Oven Aging Test Oil Immersion Test Deformation Tension Flexibility (Room and Low Temperature) Vertical Flame Room Temperature Impact Secureness of Fittings Mechanical Water Absorption Moisture Penetration Test Durability of Ink Sunlight Resistance Crush Test Pipe Stiffness for Direct Burial CSA Performance Tests Physical Properties Original Tensile and longation Air Oven Aging Test Oil Immersion Test Tension Low Temperature Flexibility Vertical Flame Cold Impact Fitting Pull-Out Fitting Liquid-Tightness Moisture Penetration Test Durability of Ink Weather Resistance 33

36 Commercial Ultraflex Mechanical Non-Metallic (NMPT) Protection Tubing Description (1) Non-UL liquidtight raceway (2) component, extra-flexible Non-Metallic mechanical protection tubing Corrugated flame resistant PVC with integral reinforcing member Non-conductive raceway black Temperature Rating 60 C Dry 60 C Wet and oily Applications recognized component for use in protection of insulated wire in assemblies or consoles of electrical apparatus. Use is to be determined by Underwriters Laboratories Inc. Non-UL liquidtight raceway References & Ratings recognized component Liquidtight Mechanical Protection Tubing under UL File Number UL1696 Standard for Non-Metallic Mechanical Protection Tubing CSA File LL69271 CSA C22.2 No Made in USA of US and/or imported materials Ordering Information Product Dimensions/ Bend Radius Approx. Internal xternal Trade Trade Coil Reel Weight/ Diameter Diameter Bend Product Size Size Length Length 100 feet (min/max) (min/max) Radius Code (inches) (mm) (feet) (feet) (pounds) inches inches (inches) / ' / / / ' / / / ' / / ' / / ' / / ' / / ' / / NOT: All dimensions and weights are subject to normal manufacturing tolerances. 34

37 Commercial Ultraflex Mechanical Non-Metallic (NMPT) Protection Tubing (1) Recognized Component (2) Non-UL Non-Metallic Conduit (NMPT) Scope This specification covers AFC Cable Systems, Inc. LIQUID-TUFF Liquidtight ULTRAFL (1) RCOGNIZD COMPONNT TRA- FLIBL NON-MTALLIC MCHANICAL PROTCTION TUBING and (2) NON-UL TRA-FLIBL NON-MTALLIC CONDUIT. (1) LIQUID-TUFF Liquidtight ULTRAFL RCOGNIZD COMPONNT TRA FLIBL NON-MTALLIC MCHANICAL PROTCTION TUBING is designed for use in connection with the support of and protection of insulated wires, placed within the tubing, that are used to interconnect separate component assemblies or consoles of electrical apparatus, such as x-ray equipment. Use of the combination is to be determined by Underwriters Laboratories Inc. The acceptable use of this material is limited to the following conditions: 1. This tubing may be used for the routing of internal wiring between electrical components of electrical equipment. The protection afforded to the internal wiring by the tubing may be considered equivalent to the protection afforded the internal conductors by the jacket of a Type SJT flexible cord. 2. The tubing is suitable for use at a maximum temperature of 60 C. 3. The tubing and manufacturer s supplied fittings were not tested to determine flammability rating per UL The tubing shall be terminated at each end of the consoles or appliances to which connected to provide strain relief to withstand a 35-pound pull for 1.0 minute. Fittings available from the manufacturer met this requirement. 5. The percent fill of the tubing with conductors shall not exceed 75% where percent fill is defined as: Percent Fill = Area of nclosed Conductors x 100/Internal Area of Tubing Fill Factor. 6. The minimum bend radius shall not be less than the outside diameter of the tubing. 7. The manufacturer s fittings were subjected to the Oil Spray Test in accordance with UL 514B. 8. As this tubing and manufacturer supplied fittings are to be Recognized as a Component, final acceptance will be determined in terms of the combination of component and appliance as determined by Underwriters Laboratories Inc., regarding such characteristics as flammability; degree of bending or flexing; resistance to water, oil and abrasion; and physical strength. Construction LIQUID-TUFF Liquidtight ULTRAFL MCHANICAL PROTCTION TUBING/CONDUIT has a circular cross section with a smooth polyvinyl chloride (PVC) inner surface and an integral reinforcing member within the conduit wall. The dimensions of the integral tubing/conduit shall comply with Table 1. Color: black Grounding Where applicable a separate grounding conductor is required for all trade sizes. Markings The product marking is contained on the outer carton. Performance Tests The completed LIQUID-TUFF Liquidtight ULTRAFL TUBING and CONDUIT shall meet the performance requirements outlined in Appendix A. Standards CSA C22.3 No UL1696 Non-metallic Mechanical Protection Tubing File UL CSA (2) LIQUID-TUFF Liquidtight ULTRAFL NON-UL TRA-FLIBL Non-Metallic CONDUIT is designed for use in wet, dry or oily locations as a flame resistant, Non-Metallic raceway for power, control and communications cables. The product is intended for use at 60 C (140 F) in a dry location, 60 C (140 F) in a wet location and 60 C (140 F) in a oily location. It is sunlight resistant. 35

38 Commercial Ultraflex Mechanical Non-Metallic (NMPT) Protection Tubing (1) Recognized Component (2) Non-UL Non-Metallic Conduit (NMPT) Table 1 Conduit Size Inside Outside Min. Trade Diameter, In. Diameter, In. Bend Weight Size, In. Metric Min. Max. Min. Max. Radii, In. lbs/100ft 3/8 (12) /2 (16) /4 (21) (27) (35) (41) (53) Appendix A PRFORMANC RQUIRMNTS Heat Aging Test Cold Bend Test Heat Shock Test Crush Test Impact Test Oil Spray Test 36

39 Commercial HYDROTIT Type COM-BLU Liquidtight Flexible Metal Conduit Description Hot-dipped zinc galvanized steel core - corrosion resistant FT-4 rated PVC jacket UV resistant Flexible in cold weather Self measuring sequential markings Applications Computer rooms OM s quipment builders CSA quipment Where flexible connections are required Specifications Available with custom print up to 200 characters long Temperature rating 75 C dry, 60 C wet, 75 C oil Standard color blue (custom colors available upon request) CSA Certified to CSA C22.2 No.56 under Files and MC CC Hazardous locations: Class I Div. 2, Class II Div (4)(b), Class II Div (4), Class III Div (4), Class III Div Meets -30 C Flexibility Test Meets -25 C Cold Impact Test Ordering Information Product Dimensions/ Bend Radius Internal (I.D.) xternal (O.D.) xternal (O.D.) Bend Part Catalog Trade Size Trade Size Reel Length Reel Weight Weight Min. Diameter Minimum Dia. Maximum Dia. Radius Number Number (inches) (mm) (meters) (kilograms) (kg/meter) In. (mm) In. (mm) In. (mm) In. (mm) CM4D0375M0030C 3/ (12.29) (17.5) (18.0) 4.0 (102) CM4D0375M0360R 3/ (12.29) (17.5) (18.0) 4.0 (102) CM4D0500M0030C 1/ (15.80) (20.8) (21.3) 6.0 (152) CM4D0500M0300R 1/ (15.80) (20.8) (21.3) 6.0 (152) CM4D0750M0030C 3/ (20.83) (25.2) (26.7) 8.0 (203) CM4D0750M0150R 3/ (20.83) (25.2) (26.7) 8.0 (203) CM4D1000M0030C (26.44) (32.8) (33.4) 10.0 (254) CM4D1000M0120R (26.44) (32.8) (33.4) 10.0 (254) CM4D1250M0015C 1-1/ (35.05) (41.4) (42.2) 12.5 (318) CM4D1250M0075R 1-1/ (35.05) (41.4) (42.2) 12.5 (318) CM4D1500M0015C 1-1/ (40.01) (47.4) (48.3) 15.0 (381) CM4D1500M0045R 1-1/ (40.01) (47.4) (48.3) 15.0 (381) CM4D2000M0015C (51.31) (59.4) (60.3) 20.0 (508) CM4D2000M0030R (51.31) (59.4) (60.3) 20.0 (508) CM4D2500M0010C 2-1/ (62.99) (72.1) (73.0) 25.0 (635) CM4D3000M0010C (77.98) (87.9) (88.9) 30.0 (762) CM4D4000M0008C (101.60) (113.3) (114.3) 40.0 (1016) 37

40 Commercial HYDROTIT Type CSA Liquid-tight Flexible Metal Conduit Description Corrosion resistant hot-dipped galvanized zinc steel core FT-4 rated PVC jacket UV resistant Flexible in cold weather Self-measuring Applications OM s quipment builders CSA quipment Where flexible connections are required Specifications Temperature rating 75 C dry, 60 C wet, 75 C oil Standard color black(custom colors available upon request) CSA Certified to CSA C22.2 No.56 under Files and MC CC Hazardous locations: Class I Div. 2, Class II Div (4)(b), Class II Div (4), Class III Div (4), Class III Div Meets -30 C Flexibility Test CSA Meets -25 C Cold Impact Test CSA Ordering Information Product Dimensions/ Bend Radius Internal (I.D.) xternal (O.D.) xternal (O.D.) Bend Part Catalog Trade Size Trade Size Reel Length Reel Weight Weight Min. Diameter Minimum Dia. Maximum Dia. Radius Number Number (inches) (mm) (meters) (kilograms) (kg/meter) In. (mm) In. (mm) In. (mm) In. (mm) HC CSAC0375M0030C 3/ (12.29) (17.5) (18.0) 4.0 (102) HC CSAC0375M0360R 3/ (12.29) (17.5) (18.0) 4.0 (102) HC CSAC0500M0030C 1/ (15.80) (20.8) (21.3) 6.0 (152) HC CSAC0500M0300R 1/ (15.80) (20.8) (21.3) 6.0 (152) HC CSAC0750M0030C 3/ (20.83) (25.2) (26.7) 8.0 (203) HC CSAC0750M0150R 3/ (20.83) (25.2) (26.7) 8.0 (203) HC CSAC1000M0030C (26.44) (32.8) (33.4) 10.0 (254) HC CSAC1000M0120R (26.44) (32.8) (33.4) 10.0 (254) HC CSAC1250M0015C 1-1/ (35.05) (41.4) (42.2) 12.5 (318) HC CSAC1250M0075R 1-1/ (35.05) (41.4) (42.2) 12.5 (318) HC CSAC1500M0015C 1-1/ (40.01) (47.4) (48.3) 15.0 (381) HC CSAC1500M0045R 1-1/ (40.01) (47.4) (48.3) 15.0 (381) HC CSAC2000M0015C (51.31) (59.4) (60.3) 20.0 (508) HC CSAC2000M0030R (51.31) (59.4) (60.3) 20.0 (508) HC CSAC2500M0010C 2-1/ (62.99) (72.1) (73.0) 25.0 (635) HC CSAC3000M0010C (77.98) (87.9) (88.9) 30.0 (762) HC CSAC4000M0008W (101.60) (113.3) (114.3) 40.0 (1016) 38

41 Flexible Metal Conduit Flexible Metal Conduit Flexible Metal Conduit Flexible Metal Conduit Reduced Wall Flexible Steel Conduit Reduced Wall Aluminum Flexible Metal Conduit xtra Flexible Conduit Flexcon xtra-flexible Steel Conduit Full Wall Flexible Metal Conduit Type RAY-FL CSA Aluminum Flexible Conduit AFC Fittings

42 Flexible Metal Conduit Flexible Metal Conduit Reduced Wall Flexible Steel Conduit Type RW FSC Description Reduced Wall Flexible Steel Conduit High grade hot dipped zinc galvanized low carbon steel Interlocking design Corrosion resistant Applications Flexible metal raceway for electrical power, control and communication cables Motor leads Listed assemblies Listed wire fixtures Manufactured wiring systems Interlocking Steel Armor References & Ratings UL 1, UL 1479, File Reference 11831, CSA File Number 15035, CSA C22.2 No. 56 (trade size 3/8 only) Federal Specification WW-C-566C, (now superseded by UL 1) NC (5), (C), 348, , (B)(2), Cable Tray installations per NC nvironmental Air-Handling space installation NC (C) UL Classified 1, 2 and 3-hour Through-Penetration Fire Systems UL File R14141 Made in USA of US and/or imported materials Ordering Information Product Dimensions/ Bend Radius Approx. Internal xternal Trade Trade Coil Reel Weight/ Diameter Diameter Bend Product Size Size Length Length 100 feet (min/max) (min/max) Radius Code (inches) (mm) (feet) (feet) (pounds) inches inches (inches) / ' / / / ' / / / ' / / / ' / / / ' / / / ' / / / ' / / / ' / / / ' / / / ' / / / ' / / / ' / / / ' / / / ' / / / ' / / / ' / / ' / / ' / / ' / / ' / / ' / / ' / / ' / / ' / / ' / 2.860/ ' / 2.860/ ' / 3.360/ ' / 3.360/ ' / 3.860/ ' / 3.860/ ' / 4.360/ ' / 4.360/ NOT: All dimensions and weights are subject to normal manufacturing tolerances. + CSA certified Review NC and (5) for grounding requirements. 40

43 Flexible Metal Conduit Flexible Metal Conduit Description Lightweight Reduced Wall Aluminum Flexible Conduit Premium aluminum alloy Interlocking design Applications Flexible metal raceway for electrical power, control and communication cables Motor leads Listed assemblies Listed wire fixtures Manufactured wiring systems Reduced Wall Aluminum Flexible Metal Conduit Type RW FAC Ordering Information References & Ratings UL 1, UL 1479, File Reference 11831, CSA File Number 15035, CSA C22.2 No. 56 (trade size 3/8 only) Federal Specification WW-C-566C, (now superseded by UL 1) NC (5), (C), 348, , (B)(2), Cable Tray installations per NC nvironmental Air-Handling space installation NC (C) UL Classified 1, 2 and 3-hour Through-Penetration Fire Systems UL File R14141 Los Angeles may allow longer lengths for grounding, check local codes for details, Application Made in USA of US and/or imported materials Product Dimensions/ Bend Radius Approx. Internal xternal Trade Trade Coil Reel Weight/ Diameter Diameter Bend Product Size Size Length Length 100 feet (min/max) (min/max) Radius Code (inches) (mm) (feet) (feet) (pounds) inches inches (inches) / ' / / / ' / / / ' / / / ' / / / ' / / / ' / / / ' / / / ' / / / ' / / / ' / / / ' / / / ' / / / ' / / / ' / / / ' / / / ' / / ' / / ' / / ' / / ' / / ' / / ' / / ' / / ' / / ' / 2.860/ ' / 2.860/ ' / 3.360/ ' / 3.360/ ' / 3.860/ ' / 3.860/ ' / 4.360/ / 4.360/ NOT: All dimensions and weights are subject to normal manufacturing tolerances. + CSA certified Review NC and (5) for grounding requirements. Interlocking Aluminum Armor 41

44 Flexible Metal Conduit Flexible Metal Conduit xtra Flexible Conduit Description Non-UL xtra Flexible Steel Conduit High grade galvanized low carbon steel Interlocking design Corrosion resistant Applications Flexible metal raceway for specific applications where UL and other agency approvals are not required Motor leads Interlocking Steel Armor Made in USA of US and/or imported materials Ordering Information Product Dimensions/ Bend Radius Approx. Internal xternal Trade Trade Coil Reel Weight/ Diameter Diameter Bend Product Size Size Length Length 100 feet (min/max) (min/max) Radius Code (inches) (mm) (feet) (feet) (pounds) inches inches (inches) / ' / / / ' / / / ' / / / ' / / / ' / / / ' / / / ' / / ' / / ' / / ' / / ' / / ' / 2.860/ ' / 3.360/ ' / 3.860/ ' / 4.360/ NOT: All dimensions and weights are subject to normal manufacturing tolerances. 42

45 Flexible Metal Conduit Flexible Metal Conduit Flexcon xtra-flexible Steel Conduit Description AFC Cable Systems, Inc. FLCON TRA-FLIBL STL CONDUIT is manufactured from one continuous length of high grade steel, hot dipped in a zinc bath for protection against the normal effects of corrosion. The steel strip is formed into interlocking convolutions firmly joined to assure a rugged yet very flexible conduit which provides exceptional flexibility for tight U-bend applications. The convolutions are manufactured to insure smoother interior and exterior surfaces, which facilitate both cable and conduit pulling. The FlexCon installs easily with standard armored cable or flexible metal conduit connectors. The product is designed to be used for specific applications where Underwriters Laboratories Inc. or other agency approvals are not required. Flexcon xtra-flexible Steel Made in USA of US and/or imported materials Ordering Information Product Dimensions/ Bend Radius Approx. Internal xternal Trade Trade Coil Reel Weight/ Diameter Diameter Bend Product Size Size Length Length 100 feet (min/max) (min/max) Radius Code (inches) (mm) (feet) (feet) (pounds) inches inches (inches) / ' / / / ' / / / ' / / / ' / / / ' / / / ' / / / ' / / NOT: All dimensions and weights are subject to normal manufacturing tolerances. 43

46 Flexible Metal Conduit Flexible Metal Conduit Full Wall Steel Flexible Metal Conduit Description Full wall flexible metal conduit High grade zinc galvanized low carbon steel Interlocked design Corrosion resistant Strongest metal conduit available Applications Flexible metal raceway for electrical power, control and communication cables Motor leads Listed assemblies Listed wire fixtures Manufactured wiring systems Full Wall Steel Armor References & Ratings UL 1, UL 1479, File Reference 11831, CSA Certified File LL15035, CSA C22.2 No. 56 Federal Specification WW-C-566C, (now superseded by UL 1) NC (5), (C), 348, , (B)(2), Cable Tray installations per NC nvironmental Air-Handling space installation NC (C) UL Classified 1, 2 and 3-hour Through-Penetration Fire Systems UL File R14141 Made in USA of US and/or imported materials Ordering Information Product Dimensions/ Bend Radius Approx. Internal xternal Trade Trade Coil Reel Weight/ Diameter Diameter Bend Product Size Size Length Length 100 feet (min/max) (min/max) Radius Code (inches) (mm) (feet) (feet) (pounds) inches inches (inches) / ' / / / ' / / / ' / / / ' / / / ' / / NOT: All dimensions and weights are subject to normal manufacturing tolerances. Review NC and (5) for grounding requirements. 44

47 Flexible Metal Conduit Flexible Metal Conduit Type RAY-FL Aluminum Flexible Conduit Description Galvanized steel core Flexible in cold weather Applications OM s quipment builders UL/CSA quipment Raceways Specifications CSA Certified to CSA C22.2 No.56 UL 1 Suitable for use in hazardous locations as per CC Class I, Zone 2 & Div.2, Class II Div. 1 & 2, Class III Div. 1 & 2 Made in USA of US and/or imported materials Interlocking Aluminum Armor Ordering Information Product Dimensions/ Bend Radius Internal (I.D.) xternal (O.D.) xternal (O.D.) Bend Part Catalog Trade Size Trade Size Reel Length Reel Weight Weight Min. Diameter Minimum Dia. Maximum Dia. Radius Number Number (inches) (mm) (meters) (kilograms) (kg/meter) In. (mm) In. (mm) In. (mm) In. (mm) ALUC0312M0075W 5/ (7.92) N/A (12.95) 3.5 (89) ALUC0375M0075W 3/ (9.52) (14.22) (15.49) 4.0 (102) ALUC0375M0300R 3/ (9.52) (14.22) (15.49) 4.0 (102) ALUC0437M0075W 7/ (11.10) N/A (17.15) 4.5 (114) ALUC0437M0300R 7/ (11.10) N/A (17.15) 4.5 (114) ALUC0500M0030W 1/ (15.88) (21.84) (23.37) 6.0 (152) ALUC0500M0300R 1/ (15.88) (21.84) (23.37) 6.0 (152) ALUC0750M0030W 3/ (20.62) (26.54) (28.07) 8.0 (203) ALUC0750M0150R 3/ (20.62) (26.54) (28.07) 8.0 (203) ALUC1000M0030W (25.40) (33.02) (35.05) 10.0 (254) ALUC1000M0120R (25.40) (33.02) (35.05) 10.0 (254) ALUC1250M0015W 1-1/ (31.75) (39.37) (41.40) 12.5 (318) ALUC1250M0075R 1-1/ (31.75) (39.37) (41.40) 12.5 (318) ALUC1500M0015W 1-1/ (38.10) (46.99) (49.53) 15.0 (381) ALUC2000M0015W (50.80) (59.69) (62.23) 20.0 (508) ALUC2500M0015W 2-1/ (63.50) (72.64) (77.72) 25.0 (635) ALUC3000M0015W (76.20) (85.34) (90.42) 30.0 (762) ALUC3500M0015W 3-1/ (88.90) (98.04) (103.12) 35.0 (889) ALUC4000M0015W (101.60) (110.74) (115.82) 40.0 (1016) 45

48 Liquid-Tuff AFC Fittings is Yopur Best Connection AFC Fittings is Your Best Connection From connectors for Type MC, AC and HCF cables, to flexible metal conduit and liquid-tight flexible conduits (metallic and non-metallic) or steel MT, Set Screw and Compression Fittings, AFC has just about any type of terminating means you require. Armored Cable and Flexible Metal Conduit Connectors AFC Steel Box Connectors are design coordinated with AC & MC Cable and Flex from AFC Cable Systems. Parking Deck and Parking Lot Cable Reasonably priced connectors that are appropriate for use with PVC Jacket MC cable (Parking Deck/Lot Cable ) Malleable Liquidtight Insulated and Uninsulated Fittings Designed and engineered to ensure excellent performance thanks to it s heavy-duty, impact resistant construction. Non-Metallic Liquidtight Connectors Available in one-piece or traditional multi-piece configurations Snap-Lok Flexible Metal Conduit Connectors Quality spring steel construction for maximum reliability and vibration resistance making it ideal for machine-fed installations. Steel Setscrew Connectors and Couplings Durable one-piece assembly available with or without insulated throats Steel Compression Connectors and Couplings Strong steel construction available with or without insulated throats Raintight Compression Fittings Inner sealing gland prevents moisture from entering the conduit Get the New AFC Fittings Catalog at, or call

49 Liquid-Tuff Chemical Resistance/Reference Information Chemical Resistance/Reference Information The information contained in the Chemical Resistance Guide has been compiled from various literature references and sources. It may be considered as a basis for chemical resistance but Chemical Resistance/Reference Information Chemical Resistance Guide Connector Cross-Reference Guide Product Comparison Chart Notes not as a guarantee. It is strongly advised that specific Liquid-Tuff products be tested under actual service conditions to determine suitability. Liquid-Tuff samples for chemical resistance testing available upon request. 47

50 Liquid-Tuff Chemical Resistance Guide Chemical Resistance Guide Jacket Material Key PVC = POLYVINYL CHLORID TPR = THRMOPLASTIC LASTOMR TPU = THRMOPLASTIC POLYURTHAN A ASTM Fuel A F G G ASTM Fuel B F F ASTM Fuel C F F ASTM Oil No. 1 G G G ASTM Oil No. 2 G ASTM Oil No. 3 F G Acetaldehyde Acetamide Acetate Solvents Acetic Acid (Glacial) F G Acetic Acid 40 G G Acetic Acid 10 G G Acetic Anhydride Acetone Acetyl Bromide Acetyl Chloride Acetylene Acrylonitrite Adipic Acid Alcohols Alcohols (Aliphatic) F Alkalies Allyl Alcohol Aluminum Salts Aluminum Chloride G Aluminum Sulfate (Alums) Aluminum Sulfide Alums Ammonia G Ammonia (Dry Gas) G Ammonia (Anhydrous Liquids) Ammonia (Aqueous) Ammoniated Latex Ammonium Acetate Ammonium Carbonate Ammonium Chloride G Ammonium Chloride 10 Ammonium Hydroxide Ammonium Nitrate Ammonium Persulfate Ammonium Salts Ammonium Sulfate Ammonium Sulfide Ammonium Thicyanide Amyl Acetate Amyl Alcohol Jacket Material Chemical % PVC TPR TPU Rating Key = RSISTANT: GOOD FOR CONTINUOUS POSUR G = GOOD FOR INTRMITTNT POSUR F = US ONLY WHR LIMITD LIF IS ACCPTABL = DO NOT US Jacket Material Chemical % PVC TPR TPU A Amyl Chloride Aniline Aniline Hydrochloride Aniline Oils Animal Fats & Oils Aniseed Oil Anthracene Antifreeze Compounds 50/50 Antimony Salts Aqua Regia Aromatic Fuels Aromatic Hydrocarbons Arsenic Salts Asphalt Attar of Roses B Banana Oil Barium Carbonate Barium Chloride Barium Hydroxide Barium Salts Barium Sulfide Battery Acid Benzaldehyde Benzaldehyde Benzene Benzine (Petroleum ther) F Benzoic Acid Benzole Benzyl Bitumen Borax Bordeaux Mixture Boric Acid G Brake Fluid Brake Fluid A Brine Bromine Bromobenzene Bunker Oil Butane G Butanol Butyl Acetate Butyl Alcohol G Butylene Glycol Butyric Acid 48

51 Liquid-Tuff Chemical Resistance Guide Chemical Resistance Guide Jacket Material Key PVC = POLYVINYL CHLORID TPR = THRMOPLASTIC LASTOMR TPU = THRMOPLASTIC POLYURTHAN Jacket Material Chemical % PVC TPR TPU C Calcium Carbonate Calcium Chloride 20 G Calcium Chloride 10 G Calcium Hydroxide Calcium Hypochlorite Calcium Nitrate Calcium Sulfate Camphor Carbolic Acid (Phenol) G Carbon Dioxide Carbon Disulfide Carbon Tetrachloride Carbonic Acid Casein Castor Oil Catechol Caustic Soda Cello-Solv Chlorinated Hydrocarbons Chlorinated Lime Chlorine Chlorine (water solution) 40 F G Chlorine Gas (dry & wet) Chloroacetic Acid Chlorobenzene Chlorobromomethane Chloroform Chrome Baths Chromic Acid 40 F Chromic Acid 10 G Chromic Acid 1 Chromium Potassium Sulfate Chromium Salts Citric Acid Coal Tar Coconut Oil F Copper Salts Corn Oil Cottonseed Oil F Creosote Cresol F Cresylic Acid Cupric Chloride Cupric Nitrate Cupric Sulfate Cyclohexane G Rating Key = RSISTANT: GOOD FOR CONTINUOUS POSUR G = GOOD FOR INTRMITTNT POSUR F = US ONLY WHR LIMITD LIF IS ACCPTABL = DO NOT US Jacket Material Chemical % PVC TPR TPU C Cyclohexanol Cyclohexanone G D DDT Weed Killer DOP DT Oil Decalin Degreasing Fluids Detergents (dish washing) Di Iso Cyante F Di Methyl Formamide Di Methyl Hydrazine Di-isodecyl Phthalate Dibutyl ther Dibutyl Phthalate Dichlorobenzene Dichloroethylene Diesel Fuel G Diesel Oils F Diester Oil Diethyl ther Diethylene Glycol G Dimethyl Acetamide Dimethyl Formamide Dioctyl Phthalate (DOP) Dioxane Dodeayl Mercaptan Dow General Weed Killer (H20) G Dow General Weed Killer (Phenol) Dowtherm dible Fats and Oils sters ther thyl Acetate thyl Alcohol (thanol) F thyl Bromide thyl Chloride thylene Chloride G thylene Dichloride thylene Glycol 50 G G thylene Oxide F Fatty Acids Ferric Chloride G Ferric Nitrate 49

52 Liquid-Tuff Chemical Resistance Guide Chemical Resistance Guide Jacket Material Key PVC = POLYVINYL CHLORID TPR = THRMOPLASTIC LASTOMR TPU = THRMOPLASTIC POLYURTHAN Jacket Material Chemical % PVC TPR TPU F Ferric Sulfate Ferrous Chloride Ferrous Sulfate Flourochlorohydrocarbons Formaldehyde 40 Formalin Formamide Formic Acid 85 Formic Acid 40 Formic Acid 10 Freon F Freon 12 Freons Fuel Oil G Furfurol F G Gallic Acid Gasoline Octane F Glycerine Glycol Glycolic Acid Grease G Green Sulfate Liquor H Heptachlor in Petroleum Solvents Heptane F G Hexane F G G Hydfaulic Fluids - ster Base Hydraulic Fluids - Petroleum Base F Hdrazine Hydrobromic Acid Hydrocarbon Oil Hydrochloric Acid (Muriatic) 40 F Hydrochloric Acid 10 G Hydrochloric Acid 1 Hydrocyanic Acid Hydrofluoric Acid 70 Hydrofluoric Acid 10 Hydrofluoroboric Acid 40 F Hydrofluoroboric Acid 10 G Hydrogen Hydrogen Chloride G Hydrogen Chloride G Hydrogen Fluoride Hydrogen Peroxide 30 G Hydrogen Peroxide 10 Rating Key = RSISTANT: GOOD FOR CONTINUOUS POSUR G = GOOD FOR INTRMITTNT POSUR F = US ONLY WHR LIMITD LIF IS ACCPTABL = DO NOT US Jacket Material Chemical % PVC TPR TPU H Hydrogen Peroxide 2 Hydrogen Sulfide Hydrolic Fluid G Hydrolodic Acid I Ink Iodine Solution Iron Salts - Acid Soln. Iron Salts - Neut. Soln. Isooctane F Isopropanal Isopropyl Acetate Isopropyl Alcohol G J JP-4 Oil Jet Fuels (JP-3,4, and 5) F K Kerosene F G Ketones L Lacquer Thinners Lactic Acid 90 F Lactic Acid 50 F Lactic Acid 5 F Lanolin Lead Acetate Lead Salts Linseed Oil Lox Lubricating Oils, Greases, Soaps M MIL-D-5606 Oil MIL-L-7808 Oil Magnesium Chloride G Magnesium Hydroxide 10 Magnesium Salts Magnesium Sulfate Malathion 50 in Aromatics Malic Acid Mercury Mercury Salts Methanol 10 Methyl Acetate Methyl Alcohol F Methyl Bromide Methylene Chloride 50

53 Liquid-Tuff Chemical Resistance Guide Chemical Resistance Guide Jacket Material Key PVC = POLYVINYL CHLORID TPR = THRMOPLASTIC LASTOMR TPU = THRMOPLASTIC POLYURTHAN Jacket Material Chemical % PVC TPR TPU M Methyl thyl Ketone Methyl Glycol Methyl Isobutyl Ketone Mineral Oil G Monochlorobenzene Motor Fuels Motor Oil 20W G Muriatic Acid (See Hydrochloric Acid) N Naphtha F Naphthalene Natural Gas Nickel Salts Nitric Acid Nitric Acid 70 F Nitric Acid 35 G Nitric Acid 10 Nitrobenzene Nitrogen Nitromethane Nitropropane N-Methyl Pyrrolidone O Octane Oil of Turpentine Oleic Acid Oleum Oxalic Acid Oxygen Oxygen - Liquid Ozone P Paint Paint Thinners Palmitic Acid Paper Chemicals Paraffin Oil G Pentachlorophenolin Oil G Pentane F Perchloric Acid 70 Perchloric Acid 10 Perchloroethylene Petroleum G Petroleum ther F Petroleum Spirits Phenol G Rating Key = RSISTANT: GOOD FOR CONTINUOUS POSUR G = GOOD FOR INTRMITTNT POSUR F = US ONLY WHR LIMITD LIF IS ACCPTABL = DO NOT US Jacket Material Chemical % PVC TPR TPU P Phenyl thyl Alcohol Phosphoric Acid 85 Phosphoric Acid 50 Phosphoric Acid 10 Photographic Developer Phthalates Pitch G Plasticizers (Phthalates,Phosphates) Polyester Resin with Styrene Potash Potassium Bromide Potassium Chlorate Potassium Chloride 40 G Potassium Cyanide Potassium Hydroxide 50 G Potassium Hydroxide 10 G Potassium Iodide Potassium Nitrate Potassium Permanganate 5 Potassium Salts Potassium Sulfate Power Steering Fluid Propane Propanol Propyl Alcohol G Propylene Glycol Pydraul Pydraul Oil G Pyridine R Resorcinol Ritchfield A Weed Killer F S SA No. 10 Oil Salicylic Acid Salt Seawater Silicic Acid Silicone Oil Silver Nitrate F Silver Salts Skydrol Oil - Type B Soap Soap Solution Sodium Acetate Sodium Bicarbonate 51

54 Liquid-Tuff Chemical Resistance Guide Chemical Resistance Guide Jacket Material Key PVC = POLYVINYL CHLORID TPR = THRMOPLASTIC LASTOMR TPU = THRMOPLASTIC POLYURTHAN Jacket Material Chemical % PVC TPR TPU S Sodium Bisulfite Sodium Borate Sodium Bromide Sodium Carbonate Sodium Carbonate Sodium Chlorate Sodium Chloride 15 G Sodium Chlorite Sodium Cyanide Sodium Dichromate Sodium Ferrocyanide Sodium Fluride Sodium Hydrosulfite Sodium Hydroxide G Sodium Hydroxide 50 Sodium Hydroxide 10 G Sodium Hypochlorite PH13 G Sodium Nitrate Sodium Nitrate Sodium Nitrite Sodium Perborate Sodium Phosphate Sodium Silicate Sodium Sulfate Sodium Sulfide Sodium Sulfite Sodium Thiosulfite Solvent Naphtha Solvesso Soybean Oil F Stoddard Solvent Styrene Sulfur Sulfur Dioxide Sulfur Dioxide (Liquid) Sulfuric Acid Sulfuric Acid 75 F Sulfuric Acid 60 G Sulfuric Acid 40 Sulfuric Acid 25 F Sulfuric Acid 10 G Sulfurous Acid 40 G T Tall Oil Tallow Tannic Acid Rating Key = RSISTANT: GOOD FOR CONTINUOUS POSUR G = GOOD FOR INTRMITTNT POSUR F = US ONLY WHR LIMITD LIF IS ACCPTABL = DO NOT US Jacket Material Chemical % PVC TPR TPU T Tar Tartaric Acid Tea Tetra thyl Lead Tetra Hydro Furan Tetrachloroethlene Tetraline Thionyl Chloride Tin Salts Titanium Salts Toluene Toluol Transformer Oil Transmission Oil F Trichlorethane Trichlorethylene Trichloroacctic Acid Tricresyl Phosphate Tricresyl Phosphate (Skydrol) Triethanol Amine F Trisodium Phosphate Tung Oil F Turpentine F F G U Urea V Varnish Varsol Vaseline Vegetable Oils and Juices Vinegar Vinyl Chloride W Water Water 23º C Water 70º C Wax Wood Preservatives ylene F ylols Z Zinc Chloride Zinc Sulfate 52

55 Liquid-Tuff Connector Cross-Reference Guide Connector Cross-Reference Guide LIQUID-TUFF Metallic Conduits xternal Dia. Trade Internal Dia. Over Conduit Over Jacket AFC Arlington Bridgeport Madison OZ Neer Regal T&B Size inch (min/max) inch (min/max) inch (min/max) Gedney 3/ / / /0.710 LS38 LT LT2 MSTR-38 4Q-38 LMM / / / /0.840 LS50 LT LT2 MSTR-50 4Q-50 LMM / / / /1.050 LS75 LT LT2 MSTR-75 4Q-75 LMM / / /1.315 LS100 LT LT2 MSTR-100 4Q-100 LMM / / /1.660 LS125 LT LT2 MSTR-125 4Q-125 LMM / / /1.900 LS150 LT LT2 MSTR-150 4Q-150 LMM / / /2.375 LS200 LT LT2 MSTR-200 4Q-200 LMM / / /2.875 LS250 LT LT2 MSTR-250-B 4Q-250 LMM / / /3.500 LS300 LT LT2 MSTR-300-B 4Q-300 LMM / / /4.000 LS350 LT LT2 MSTR-350-B 4Q-350 LMM-85 LT-209* / / /4.500 LS400 LT LT2 MSTR-400-B 4Q-400 LMM LIQUID-TUFF Non-Metallic Conduits Trade Internal Dia. xternal Dia. AFC Arlington Bridgeport Madison Neer Regal T&B Size inch (min/max) inch (min/max) 3/ / / NMLT NMLT NMLQ-1038 LMM-01 LT38P 1/ / / NMLT NMLT NMLQ-1050 LMM-11 LT50P 3/ / / NMLT NMLT NMLQ-1075 LMM-21 LT75P / / NMLT NMLT NMLQ-1100 LMM-31 LT100P / / NMLT NMLT NMLQ-1125 LMM-41 LT125P / / NMLT NMLT NMLQ-1150 LMM-51 LT150P / / NMLT NMLT NMLQ-1200 LMM-61 LT200P Flexible Metal Conduits Full Wall, Reduced Wall, and Type F Steel/Aluminum Flexible Conduits Trade Internal Dia. xternal Dia. AFC Arlington Bridgeport lectroline/ OZ Neer Regal T&B Size inch (min/max) inch (min/max) Steel City Gedney 5/ / / / / /0.610 AFC-50,52** L DC2 L42/C-269 C-5 SC / / /0.920 AFC-75**, 5075 L DC2 L42-1/C-270 C-8 SC / / /1.105 L DC2 L42-2/C SC / /1.380 L DC2 L42-3/C SC / /1.630 L DC2 L42-4/C SC / /1.950 L DC2 L42-5/C SC / /2.450 L DC2 L42-6/C SC /3.060 L DC2 L42-7/C SC /3.560 L DC2 L42-8/C SC /4.060 L DC2 L42-9/C-278A KC--350 SC /4.560 L DC2 L42-10/C-2710 KC-400 SC * Denotes manufactured by Steel City ** For RW Flexible Metal Conduit For RW Flexible Metal Conduit in steel only All brand names, product names and trademarks are the property of their respective holders. * The connector cross-reference guide is provided as a service to our customers. The information contained herein is based on manufacturer published literature. Consult appropriate manufacturer for more information. 53

56 Liquid-Tuff Product Comparison Chart Product Comparison Chart Brand Product Halogen Oil Acid Sun Direct Size Working Listings Free Resistant Resistant Resistant Burial Range Temperature General Purpose Listed Products AFC UL LFMC 3/8" - 4." -30C/80C Dry- 70C-Oil UL/CSA Direct burial all sizes AFC UL Computer Blue 3/8" - 4." -20C/80 Dry- 70C Oil UL/CSA Direct burial all sizes AFC CSA LFMC 3/8" - 4." -20C/75C Dry- 60C Oil CSA Direct burial all sizes, No Bond Wire lectri-flex LA 3/8" - 4." -30C/80C Dry- 70C Oil UL/CSA lectri-flex CSA 3/8" - 4." -40C/75C Dry- NL Oil CSA No Bond wire lectri-flex LA/Blu 3/8" - 4." -30C/80C Dry- 70C Oil UL/CSA Anamet UA 3/8" - 4." -20C/60C Dry- 60C Oil UL/CSA Direct burial approval to 2.0" Southwire UL 3/8" - 4." -30C/80C Dry- 60C-Oil UL/CSA Southwire CB 3/8" - 4." -30C/80C Dry- 60C-Oil UL/CSA Splash Zone Products AFC/KT Food Grade 3/8" - 4." -30C/80C Dry- 70C Oil UL/CSA NSF 169 Certified lectri-flex LTFG 3/8" - 2." -20C/60C Dry- NL Oil NSF 169 Certified Anamet FG 3/8" - 2." -20/60C Dry- 60C Oil NSF 169 Certified All Temperature Products AFC Hi-Lo Temp 3/8" - 4." -55C/105C Dry- 70C Oil UL Direct burial all sizes lectri-flex ATLA 3/8" - 4." -55C/105C Dry- 70C Oil UL/CSA Anamet HTUA Not Listed 3/8" - 4." -46/105C Dry- NL Oil UL Southwire HC 3/8" - 4." -40C/105C Dry NL Oil Low Smoke Zero Halogen Products AFC LSZH 3/8" - 4." -30C/80C Dry- 70C-Oil AFC UL LSZH 3/8" - 4." -30C/80C Dry- 70C-Oil UL lectri-flex ZHLA 3/8" - 4." -40C/80C Dry- 70C-Oil UL Anamet ZHUA Not Listed 3/8" - 4." -30C/80C Dry- 70C-Oil UL Southwire NH 3/8" - 4." -10C/80C Dry- 60C-Oil Oil Resistant Products AFC HighTemp/OR 3/8" - 4." -26/C105 Dry-70C Oil PVC lectri-flex LOR Not Listed Not Listed 3/8" - 6." -20C/60C Dry - NL Oil PVC Anamet OR Not Listed 3/8" - 6." -23C/105C Dry- NL Oil PVC xtra Flexible Products AFC Non-UL LFMC 3/8" - 4." -20C/60C Dry- 60C Oil lectri-flex LT 5/16" - 6." -20C/80C Dry - NL Oil lectri-flex F Not Listed 3/8" - 2." -20C/80C Dry- 60C Oil Anamet FST 3/8" - 6." -20C/60C Dry- 60C Oil Anamet LD/F 3/8" - 2." -20C/60C Dry- 60C Oil Anamet F 3/8" - 2." -20C/60C Dry- 60C Oil Southwire F 3/8" - 4." -10C/60C Dry- 60C Oil Additional Non-Listed Products AFC LSZH 3/8" - 2.5" -30C/80C Dry- 70C-Oil TPU AFC xtreme Temp Not Listed Not Listed 3/8" - 4." -60C/150C Dry- NL Oil TPR lectri-flex AT Not Listed Not Listed 3/8" " -60C/150C Dry- NL Oil TPR lectri-flex CA Not Listed Not Listed 3/8" - 6." -20C/100C Dry- NL Oil TPU All brand names, product names and trademarks are the property of their respective holders. * 54

57 Liquid-Tuff AFC Notes 55

58 Liquid-Tuff

59 Built to Protect and Defend. AFC Liquid-Tuff Conduits Whether you need to protect wiring from extreme temperatures, harsh environmental conditions, or halogen free requirements, AFC has the right solution for your job. This completely re-engineered line of industrial and commercial liquid-tight flexible metal and non-metallic conduits offer variety, strength, and flexibility to shield wiring in any condition. Learn more at afcweb.com

60 960 Flaherty Drive New Bedford, MA PHON / TOLL-FR / Atkore International, Inc. All rights reserved. AFC-L

PHOTOVOLTAIC CABLES. Photovoltaic Cable 2000V/1500V Photovoltaic Cable 2000V/1000V

PHOTOVOLTAIC CABLES. Photovoltaic Cable 2000V/1500V Photovoltaic Cable 2000V/1000V PHOTOVOLTAIC CABLES PHOTOVOLTAIC CABLES INDEX n AmerSol Dual-Certified (UL / ETL) Photovoltaic Cable 2000V/1500V....................... 2-3 n AmerSol Dual-Certified (UL / ETL) Photovoltaic Cable 2000V/1000V.......................

More information

AFC Cable Systems: the Cable Industry Leader for Over 80 Years

AFC Cable Systems: the Cable Industry Leader for Over 80 Years AFC Cable Systems: the Cable Industry Leader for Over 80 Years AFC Cable Systems, Inc, is proud to announce the launch of two new Type MC cables, MC-Quik and MC-Stat. These two new cables offer the fastest

More information

CATALOG LIQUID-TUFF FLEXIBLE LIQUIDTIGHT CONDUIT CATALOG. Industrial & Commercial Liquidtight Conduit Flexible Metal Conduit

CATALOG LIQUID-TUFF FLEXIBLE LIQUIDTIGHT CONDUIT CATALOG. Industrial & Commercial Liquidtight Conduit Flexible Metal Conduit CATALOG LIQUIDTIGHT FLIBL NON-MTALLIC CONDUIT LIQUID-TUFF FLIBL LIQUIDTIGHT CONDUIT CATALOG Industrial & Commercial Liquidtight Conduit Flexible Metal Conduit A PART OF 1 2 LIQUID-TUFF Liquidtight Flexible

More information

CORFLEX. TYPE MC-HL & MV-105 or MC-HL OIL & GAS CABLES

CORFLEX. TYPE MC-HL & MV-105 or MC-HL OIL & GAS CABLES CORFLEX TYPE MC-HL & MV-105 or MC-HL OIL & GAS CABLES INDEX Instrumentation Cables - Pairs and Triads (0V*)... 2 - The Original MC-HL Technology In 1958 Canada Wire and Cable, which s now part of Nexans,

More information

SECTION LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES (600 VOLTS AND BELOW)

SECTION LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES (600 VOLTS AND BELOW) SECTION 26 05 21 PART 1 - GENERAL 1.1 DESCRIPTION This section specifies the furnishing, installation, and connection of the low voltage power and lighting wiring. 1.2 RELATED WORK A. Excavation and backfill

More information

CORFLEX TYPE MC-HL POWER, CONTROL & INSTRUMENTATION CABLES

CORFLEX TYPE MC-HL POWER, CONTROL & INSTRUMENTATION CABLES CORFLEX TYPE MC-HL POWER, CONTROL & INSTRUMENTATION CABLES CORFLEX TYPE MC-HL POWER, CONTROL & INSTRUMENTATION CABLES INDEX Corflex MC-HL Instrumentation - Pairs and Triads (0V*)... 1 - CORFLEX Cables

More information

IDENTIFYING TRAY CABLES FOR YOUR NEXT INSTALLATION A WHITE PAPER

IDENTIFYING TRAY CABLES FOR YOUR NEXT INSTALLATION A WHITE PAPER IDENTIFYING TRAY CABLES FOR YOUR NEXT INSTALLATION A WHITE PAPER Published 3/23/2012 T hough rapidly increasing in popularity, tray cables are still a point of confusion for many. While the term tray cable

More information

TABLE OF CONTENTS CHAPTER 2 WIRING AND PROTECTION CHAPTER 1 GENERAL RULES... 19

TABLE OF CONTENTS CHAPTER 2 WIRING AND PROTECTION CHAPTER 1 GENERAL RULES... 19 TABLE OF CONTENTS About This Textbook...xi How to Use the National Electrical Code... 1 Article 90 Introduction to the National Electrical Code... 7 90.1 Purpose of the NEC... 7 90.2 Scope of the NEC...

More information

Labeling to Article 690 of the National Electrical Code Routing and Protecting PV Cables

Labeling to Article 690 of the National Electrical Code Routing and Protecting PV Cables Labeling to Article 690 of the National Electrical Code Routing and Protecting PV Cables Article 690 labeling requirements from the NEC 2011 Edition General overview of industry labeling Labeling updates

More information

DUCTING & VACUUM HOSE

DUCTING & VACUUM HOSE DUCTING & VACUUM HOSE 11 VACUUM HOSE An extremely flexible and lightweight hose for vacuuming wet or dry materials in shops and car washes. The hose is crush-proof because it returns to its original shape

More information

A DIVISION OF HOSE & TUBING CATALOG 2017

A DIVISION OF HOSE & TUBING CATALOG 2017 A DIVISION OF HOSE & TUBING CATALOG 2017 Hose assemblies fabricated to customer requirements - our specialty. Let us know what your requirements are. Hose branding - just one of the value added services

More information

Double insulated, electron-beam cross-linked, halogen free photovoltaic wire sunlight resistant. Single conductor, flame retardant insulation.

Double insulated, electron-beam cross-linked, halogen free photovoltaic wire sunlight resistant. Single conductor, flame retardant insulation. Technical Data Sheet BETAflam Solar 125 flex UL 4703 Description Double insulated, electron-beam cross-linked, halogen free photovoltaic wire sunlight resistant. Single conductor, flame retardant insulation.

More information

Flexible Power Cable DLO

Flexible Power Cable DLO 37-119 Flexible Power Cable DLO 2000 Volts 90 C Diesel Locomotive Cable Limited Smoke (Sizes 2/0 and higher) EP/CPE RHH, RHW-2 Flexible-stranded, tin-coated annealed copper Flame retardant, oil and sunlight

More information

Comtran Cable. Hub-LINK Cables for Transit Applications

Comtran Cable. Hub-LINK Cables for Transit Applications Comtran Cable Hub-LINK Cables for Transit Applications Overview Hub-LINK rail transit cables are designed to resist the rugged conditions of the underground and at-grade environments, including: Temperature

More information

A. Product Data: For each electrical identification product indicated. B. Comply with 29 CFR and 29 CFR

A. Product Data: For each electrical identification product indicated. B. Comply with 29 CFR and 29 CFR September 2012, rev. 00 26 0553 Identification for Electrical Systems PART 1. GENERAL 1.01 Summary A. Section Includes: 1.02 Submittals 1. Identification for raceways. 2. Identification of power and control

More information

CONNECTION SYSTEMS TRANSIT APPLICATIONS

CONNECTION SYSTEMS TRANSIT APPLICATIONS CNNECTIN SYSTEMS TRANSIT APPLICATINS Ensure electrical and mechanical reliability with the engineered products and solutions of Shawcor s Connection Systems group INTEGRITY IS BEHIND EVERYTHING WE D. By

More information

ULTRA DYNAMIC HOSE PRODUCTS HOSE & TUBING CATALOG 2018 A DIVISION OF UBBER MPANY, INC. RUBBER COMPANY, INC RUBBER COMPANY, INC.

ULTRA DYNAMIC HOSE PRODUCTS HOSE & TUBING CATALOG 2018 A DIVISION OF UBBER MPANY, INC. RUBBER COMPANY, INC RUBBER COMPANY, INC. ULTRA DYNAMIC HOSE PRODUCTS HOSE & TUBING CATALOG 2018 A DIVISION OF RUBBER COMPANY, INC. UBBER MPANY, INC. RUBBER COMPANY, INC Hose assemblies fabricated to customer requirements - our specialty. Let

More information

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards Change History Date Description of Change Pages / Sections Modified Change Approver Initials 8/1/17 Updated section on Manufacturers 3 1. 6/15/16 Updated division section from 16120 to 26 05 00, - mgl44

More information

2016 CDM Smith All Rights Reserved July 2016 SECTION FIBER OPTIC DATA NETWORK

2016 CDM Smith All Rights Reserved July 2016 SECTION FIBER OPTIC DATA NETWORK PART 1 GENERAL 1.01 SCOPE OF WORK SECTION 27 12 23 FIBER OPTIC DATA NETWORK A. Furnish, install, terminate, and test all fiber optic equipment and cabling necessary for a complete and functional data highway

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Presley House Presley Way Crownhill Milton Keynes MK8 0ES United Kingdom Contact: Jeremy Hodge Tel: +44 (0) 1908 267300 Fax: +44 (0) 1908

More information

ELECTRIC and NEON SIGN STANDARDS. By Randy Wright RKW CONSULTING

ELECTRIC and NEON SIGN STANDARDS. By Randy Wright RKW CONSULTING SEMINAR 301 Part 1: Changes in the 2005 NEC SEMINAR RULES: There are no Rules All Questions need to be asked Stop at any time for an explanation SEMINAR PARTS: ELECTRIC and NEON SIGN STANDARDS By Randy

More information

Brand Portable Power Cord & Control Cable Solutions

Brand Portable Power Cord & Control Cable Solutions Carol Brand Portable Power Cord & Control Cable Solutions for the Entertainment Market General Cable s Carol Brand portable power cord and control cable solutions are manufactured for use in the entertainment

More information

Wiring Duct Product Selection Guide

Wiring Duct Product Selection Guide Wiring Duct Product Selection Guide Comprehensive Wiring Duct Solutions PVC Flush Cover Wiring Duct Standard 2m lengths, sold base and cover together. Type ENC, Narrow Slots, Narrow Fingers Type EWC, Wide

More information

Flame Retardant Polyethylene Tubing

Flame Retardant Polyethylene Tubing Flame Retardant Polyethylene Tubing Classified Under U.L. 1820. Performance Pipe DRISCOPLEX 2600 Instube Flame Retardant (FR) Polyethylene Tubing For Pneumatic Instrument Controls PERFORMANCE PIPE is the

More information

Pneumatic Tubing POLYTUBING O.D. 5/32"

Pneumatic Tubing POLYTUBING O.D. 5/32 Pneumatic Tubing POLYTUBING O.D. 5/32" 1/4" 3/8" 1/2" PART NR COLOR COIL LENGTH MASTER PACK MASTER PACK WT. 1063636 TWIN TUBE 500' 1000' 16# 1063635 BLACK 500' 2000' 17# 1063641 BLUE 500' 2000' 17# 1063765

More information

ZH Low Smoke 0-Halogen Flameretardant Identification Sleeves

ZH Low Smoke 0-Halogen Flameretardant Identification Sleeves STANDARD TUBE COLOR ZH Low Smoke 0-Halogen Flameretardant Identification Sleeves TECHNICAL DATA SHEET Revision Number. 1 Last Edited 24. juli 2018 The ZH-2X Heat Shrinkable Wire Markers are made of halogen

More information

Corra/Clad MC Cable The contractors cable of choice in place of conduit and wire.

Corra/Clad MC Cable The contractors cable of choice in place of conduit and wire. Corra/Clad MC Cable The contractors cable of choice in place of conduit and wire. Installs fast and easy Lowers labor costs Replaces conduit and wire Provides superior grounding UL Listed Corra/Clad MC

More information

High Performance LSZH Fire Resistant Cable

High Performance LSZH Fire Resistant Cable High Performance LSZH Fire Resistant Cable www.cavicel.com 104/2 FIRECEL SR 114H is the long and well established CAVICEL fire resistant cable in the market, since many years. These cables are third party

More information

ORDINANCE NO

ORDINANCE NO ORDINANCE NO. 2017-08-031 AN ORDINANCE OF THE CITY OF LANCASTER, TEXAS, REPEALING THE NATIONAL ELECTRICAL CODE 2014 EDITION IN ITS ENTIRETY AND REPLACING IT WITH THE ADOPTION OF THE NATIONAL ELECTRICAL

More information

IEC UNE DESIGN. 1. Conductor. 2. Insulation. Cross-linked polyethylene (XLPE) 3. Outer sheath. Flexible PVC, black colour.

IEC UNE DESIGN. 1. Conductor. 2. Insulation. Cross-linked polyethylene (XLPE) 3. Outer sheath. Flexible PVC, black colour. 67 POWERFLEX RV-K POWERFLEX RV-K Industrial flexible cable for power transmission. 1 IEC 60502-1 - UNE 21123-2 DESIGN 1. Conductor 2 Electrolytic copper, class 5 (flexible), based on EN 60228 and IEC 60228.

More information

Industrial Fiber Optic Cables, LSZH Corrugated Armored Cable, Fibers

Industrial Fiber Optic Cables, LSZH Corrugated Armored Cable, Fibers Features and Benefits Corrugated armor Mechanical protection Low-smoke/zero-halogen (LSZH ) sheath Key life-safety benefit Meets cyclic impact and chemical resistance test Superior performance Tray-rated

More information

Amerex Clean Agent System with FM200. Potential Applications: System Coverage Overview: Approvals and Standards:

Amerex Clean Agent System with FM200. Potential Applications: System Coverage Overview: Approvals and Standards: Amerex Clean Agent System with FM200 Utilizing the industry recognized FM-200 suppression agent, Amerex has developed an affordable pre-engineered clean agent fi re suppression system to protect areas

More information

600/1000V SR Insulated Flexibles Control Cables (2-4 Cores & Multicores)

600/1000V SR Insulated Flexibles Control Cables (2-4 Cores & Multicores) 600/1000V SR Insulated Flexibles Control Cables (2-4 Cores & Multicores) FFX400 1SZ1-R(PH60)(CU/SR/LSZH 600/1000V Class 2) FFX400 1SZ1-F(PH60)(CU/SR/LSZH 600/1000V Class 5) Silicone Rubber Insulation Plain

More information

Electrical Tech Note 107

Electrical Tech Note 107 Electrical Tech Note 107 Biosystems & Agricultural Engineering Department Michigan State University Understanding the Construction Code Rules, Part 8 1 Based on the 2014 NEC and the 2015 MRC The State

More information

MARATHON HEATER. File # E Made in USA

MARATHON HEATER. File # E Made in USA MARATHON HEATER S I L I C O N E R U B B E R H E A T E R S File # E202904 Made in USA Wire wound Silicone Rubber Heaters Marathon Heater flexible heaters provide outstanding performance in applications

More information

Tratos Railway Cables

Tratos Railway Cables January 2013 Tratos Railway Cables Cables for a moving world www.tratos.eu Introduction Tratos Cavi is a company specialising in the production of power, signalling, control and telecommunications cables

More information

LAPP GROUP NORTH AMERICA CABLE ATTRIBUTES QUICK GUIDE

LAPP GROUP NORTH AMERICA CABLE ATTRIBUTES QUICK GUIDE LAPP GROUP NORTH AMERICA CABLE ATTRIBUTES QUICK GUIDE LAPP User Guide Through continual Research & Development and the extensive knowledge of our engineers; the Lapp Group has developed criteria which

More information

CIR AG Power Cables. CIR AG Control Cable. CIR Type VFD Cable. CIR AG Ratings & Approvals. n UL Listed as Type TC-ER n UL Listed as TC-ER-HL (E123629)

CIR AG Power Cables. CIR AG Control Cable. CIR Type VFD Cable. CIR AG Ratings & Approvals. n UL Listed as Type TC-ER n UL Listed as TC-ER-HL (E123629) Gexol CIR ARCTIC GRADE (AG) Crush and Impact Resistant Without External Armoring Passes the same stringent crush and impact testing required by UL 2225 for Type MC-HL n Shortest Lead Times Standard 8-10

More information

Helically wound resistance wire coil made

Helically wound resistance wire coil made Ceramic Insulated CHANNEL STRIP HEATERS A Reliable Heat Source with Seamless Stainless Steel Sheath For Flat Surface Mounting Installations, Used in Hundreds Of Industrial and Commercial Heating Applications...

More information

DNVGL-CP-0401 Edition February 2016

DNVGL-CP-0401 Edition February 2016 CLASS PROGRAMME Type approval DNVGL-CP-0401 Edition February 2016 The electronic pdf version of this document, available free of charge from http://www.dnvgl.com, is the officially binding version. FOREWORD

More information

Wires, Cables, Cords and Adhesive Tapes

Wires, Cables, Cords and Adhesive Tapes 702-CRC-006-E Revision: 08 Page: 1/34 Elaborated by: Douglas Ferreira Checked by: Nelson A. Coelho Approved by: Arnaldo Barbulio Filho Approval date: 23\08\13 1 OBJECTIVE This document presents the complementary

More information

Thermocouple Cable TRANSMITTING, SENSING, MEASURING

Thermocouple Cable TRANSMITTING, SENSING, MEASURING Thermocouple Cable TRANSMITTING, SENSING, MEASURING Our Commitment Our commitment to our customers is simple - we deliver even when others can t. As one of Canada s largest wire, cable and data communication

More information

CMZH Low Smoke 0-Halogen Flame- Retardant Mass Transit Tag

CMZH Low Smoke 0-Halogen Flame- Retardant Mass Transit Tag STANDARD COLOR CMZH Low Smoke 0-Halogen Flame- Retardant Mass Transit Tag TECHNICAL DATA SHEET Revision Number. 1 Last Edited 9. januar 2019 OTHER COLORS MATERIAL Flat band cross linked polyolefin. OPERATING

More information

Optical Fibre Cable Technical Specification. Duct Cable GYTA-72B1.3

Optical Fibre Cable Technical Specification. Duct Cable GYTA-72B1.3 VersionGYTA-72B1.3 Optical Fibre Cable Technical Specification Duct Cable GYTA-72B1.3 Yangtze Optical Fibre and Cable Joint Stock Limited Company All rights reserved www.yofc.com All Rights Reserved Copyright

More information

You work hard on your panel. we work hard in your panel. PRODUCTS FOR

You work hard on your panel. we work hard in your panel. PRODUCTS FOR You work hard on your panel we work hard in your panel. PRODUCTS FOR 2 PRODUCTS FOR You simply won t find better panel components. Thomas & Betts has everything you need to make your panel better than

More information

Oberon s National Electric Code (NEC)Compliance Statement and Underwriters Laboratories (UL ) Considerations for Oberon Products

Oberon s National Electric Code (NEC)Compliance Statement and Underwriters Laboratories (UL ) Considerations for Oberon Products Oberon s National Electric Code (NEC)Compliance Statement and Underwriters Laboratories (UL ) Considerations for Oberon Products Manufacturers Statement of Compliance with NFPA 70, National Electric Code,

More information

SECTION (15820) - AIR DUCT ACCESSORIES

SECTION (15820) - AIR DUCT ACCESSORIES PART 1 GENERAL 1.01 SUMMARY A. Section includes: SECTION 23 33 00 (15820) - AIR DUCT ACCESSORIES 1. Manual-Volume Dampers 2. Fire Dampers 3. Turning Vanes 4. Duct-Mounted Access Doors 5. Flexible Connectors

More information

CIR CRUSH & IMPACT RESISTANT OIL & GAS CABLES

CIR CRUSH & IMPACT RESISTANT OIL & GAS CABLES CIR CRUSH & IMPACT RESISTANT OIL & GAS CABLES Gexol CIR Crush and Impact Resistant Without External Armoring Passes the same stringent crush and impact testing required by UL 2225 for Type MC-HL Index

More information

CIR CRUSH & IMPACT RESISTANT ARCTIC GRADE OIL & GAS CABLES

CIR CRUSH & IMPACT RESISTANT ARCTIC GRADE OIL & GAS CABLES CIR CRUSH & IMPACT RESISTANT ARCTIC GRADE OIL & GAS CABLES Gexol CIR ARCTIC GRADE (AG) Crush and Impact Resistant Without External Armoring Passes the same stringent crush and impact testing required by

More information

Photovoltaic Cables EN H1Z2Z2-K

Photovoltaic Cables EN H1Z2Z2-K Photovoltaic Cables EN 50618 H1Z2Z2-K COMPANY PROFILE Caledonian, established in 1978, offers one of the most complete lines of fiber and copper cabling system solutions with over hundreds of different

More information

SECTION (16075) - IDENTIFICATION FOR ELECTRICAL SYSTEMS

SECTION (16075) - IDENTIFICATION FOR ELECTRICAL SYSTEMS SECTION 26 05 53 (16075) - IDENTIFICATION FOR ELECTRICAL SYSTEMS PART 1 GENERAL 1.01 SUMMARY A. Section Includes: 1. Electrical identification materials and devices required to comply with ANSI C2, NFPA

More information

Nuclear Power Plant LSZH Cable Overview

Nuclear Power Plant LSZH Cable Overview Nuclear Power Plant LSZH Cable Overview While still dominant, wire and cable usage of halogenated compounds in wire and cable, particularly PVC, has decreased over the past several years. Low-smoke, zero

More information

Duct Cable GYTS-144B1.3

Duct Cable GYTS-144B1.3 Optical Fibre Cable Technical Specification Duct Cable GYTS-144B1.3 Xcom Ltd All rights reserved 1. Scope This Specification covers the design requirements and performance standard for the supply of optical

More information

DuraLife TM FPL. Installation Guide. UL 2196 Fire Rated Alarm Cables. Authorities Having Jurisdiction should be consulted before installation.

DuraLife TM FPL. Installation Guide. UL 2196 Fire Rated Alarm Cables. Authorities Having Jurisdiction should be consulted before installation. UL LISTED FPL FIRE ALARM CABLES; 2-HOUR FIRE RATED Unshielded - 16AWG - 14AWG; 2-conductor NEC Type FPL; for use in Electrical Circuit Integrity System FHIT.28A. Installation Guide Authorities Having Jurisdiction

More information

outdoor and indoor campus backbone, building backbone (riser) FDDI, Gigabit Ethernet and ATM Easy to install direct burial halogen-free

outdoor and indoor campus backbone, building backbone (riser) FDDI, Gigabit Ethernet and ATM Easy to install direct burial halogen-free GUSN Central Loose Tube Cables (Distribution) Universal Indoor/ Outdoor A/I-DQ(ZN)BH Standard Rodent Protection 05-04-8 v0.0 Ordering Information Belden Part Numbers Fibre Description / count 4 6 8 6 4

More information

Chapter 1 General... 5

Chapter 1 General... 5 About This Textbook...xi About the National Electrical Code...xv About the Authors and Illustrator...xix About the Team...xxi Article 90 Introduction to the National Electrical Code... 1 90.1 Purpose of

More information

Flexible Heaters. of Silicone Rubber & Kapton

Flexible Heaters. of Silicone Rubber & Kapton Flexible Heaters INTRODUCTION Durex Industries flexible heating elements are providing customers their optimal thermal solution in over twenty different OEM markets. Durex s unique approach to flexible

More information

SECTION EXTERIOR LIGHTING

SECTION EXTERIOR LIGHTING SECTION 26 56 00 PART 1 - GENERAL 1.1 DESCRIPTION This section specifies the furnishing, installation, and connection of exterior luminaries, controls, poles and supports. 1.2 RELATED WORK A. Section 26

More information

COMMON WORK RESULTS FOR ELECTRICAL: Basic Electrical Materials Methods

COMMON WORK RESULTS FOR ELECTRICAL: Basic Electrical Materials Methods 1. BASIC ELECTRICAL MATERIALS 1. All conduit and raceway must be 3/4" or larger. Exposed raceway in finished areas shall be in 700 or larger wiremold. Exception: runs to individual devices 10 or less,

More information

DNVGL-CP-0402 Edition February 2016

DNVGL-CP-0402 Edition February 2016 CLASS PROGRAMME Type approval DNVGL-CP-0402 Edition February 2016 The electronic pdf version of this document, available free of charge from http://www.dnvgl.com, is the officially binding version. FOREWORD

More information

industry solutions: military

industry solutions: military industry solutions: military MC industry Solutions: Military A tradition of leadership in technology, product performance for military applications Optical Cable Corporation is a leading manufacturer of

More information

Oberon s NEC Compliance Statement and Underwriters Laboratories (UL ) Considerations for Oberon Products

Oberon s NEC Compliance Statement and Underwriters Laboratories (UL ) Considerations for Oberon Products Oberon s NEC Compliance Statement and Underwriters Laboratories (UL ) Considerations for Oberon Products Manufacturers Statement of Compliance with NFPA 70, National Electric Code Oberon s suspended ceiling

More information

SECTION ELECTRICAL IDENTIFICATION

SECTION ELECTRICAL IDENTIFICATION SECTION 16075 - ELECTRICAL IDENTIFICATION PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

A Look at General Cable s GenFree II Product Line

A Look at General Cable s GenFree II Product Line L O W - S M O K E, Z E R O - H A L O G E N C A B L E S : B R I D G I N G T H E P E R F O R M A N C E G A P Next Generation Low-Smoke, Zero-Halogen (LSZH) Thermoset Insulation A Look at General Cable s

More information

Belden Infinity C-TC+ Cables for Extreme Flexing

Belden Infinity C-TC+ Cables for Extreme Flexing Product Bulletin PB 0 Belden Infinity Cables These highly flexible control, power, video and data cables handle the rigorous speeds and near-constant motion of C-track systems, robots, pick-and-place machines,

More information

SECTION ELECTRICAL GENERAL PROVISIONS

SECTION ELECTRICAL GENERAL PROVISIONS PART 1 GENERAL 1.01 SECTION INCLUDES A. General provisions for Electrical Systems B. Wire and cable for 600 volts and less. C. Wiring connectors. D. Electrical tape. E. Heat shrink tubing. F. Wire pulling

More information

Installation Manual. Vent Kit for Condensing Tankless Gas Water Heater

Installation Manual. Vent Kit for Condensing Tankless Gas Water Heater Installation Manual NORITZ AMERICA CORPORATION Vent Kit for Condensing Tankless Gas Water Heater Model: N-FlexKit2"-35 Applicable Model NRC663-FSV Potential dangers from accidents during installation and

More information

Dryflex FLAM. Halogen-Free Flame Retardant TPEs

Dryflex FLAM. Halogen-Free Flame Retardant TPEs Dryflex FLAM Halogen-Free Flame Retardant TPEs CONTENTS BRAND NAMES & NOMENCLATURE INTRODUCTION KEY PROPERTIES FLAM 600 SERIES FLAM 700 SERIES TYPICAL APPLICATIONS EXPLANATION OF FLAMMABILITY TESTS PROCESSING

More information

Copper LAN cable. This specification describes the general requirements for AMP NETCONNECT* copper LAN cable.

Copper LAN cable. This specification describes the general requirements for AMP NETCONNECT* copper LAN cable. Product Specification 108-93018 25/Aug/2011 Rev H Copper LAN cable 1. SCOPE 1.1. Content This specification describes the general requirements for AMP NETCONNECT* copper LAN cable. 2. APPLICABLE DOCUMENTS

More information

Drexan Energy Systems Inc.

Drexan Energy Systems Inc. Drexan Energy Systems Inc. SPECIFICATION Self-Regulating Heating Cable PipeGuard Warm Page 1 of 8 CONTENTS 1. SCOPE 2. PRODUCTS 3. TESTING 4. MARKINGS 5. PACKING 6. GENERAL 7. INSTALLATION AND COMMISSIONING

More information

GUCN. Central Loose Tube Cables Universal Indoor / Outdoor - Corrugated Steel Tape Armor (CST) A/I-DQ(ZN)(SR)H Full Rodent Protection v13.

GUCN. Central Loose Tube Cables Universal Indoor / Outdoor - Corrugated Steel Tape Armor (CST) A/I-DQ(ZN)(SR)H Full Rodent Protection v13. GUCN Central Loose Tube Cables Universal Indoor / Outdoor - Corrugated Steel Tape Armor (CST) A/I-DQ(ZN)(SR)H Full Rodent Protection 07-07-05 v3.0 Ordering Information Belden Part Numbers Fibre Description

More information

Compact Module. Category 6A FTP Cabling System 1.1

Compact Module. Category 6A FTP Cabling System 1.1 Updated 24/09/12 Compact Module Cat 6A performance Suitable for 10-Gigabit Ethernet Ultra-slimline design Euro style module Interchangeable with other Euro Modules and blanks Individually QA tested Easy

More information

C. Manufactured double wall chimneys for fuel fired equipment. D. NFPA 54 - National Fuel Gas Code; National Fire Protection Association; 2009.

C. Manufactured double wall chimneys for fuel fired equipment. D. NFPA 54 - National Fuel Gas Code; National Fire Protection Association; 2009. SECTION 235100 - BREECHINGS, CHIMNEYS, AND STACKS PART 1 GENERAL 1.1 SECTION INCLUDES A. Fabricated breechings. B. Manufactured chimneys for gas fired equipment. C. Manufactured double wall chimneys for

More information

PERFORMANCE POLYMER SOLUTIONS

PERFORMANCE POLYMER SOLUTIONS PERFORMANCE POLYMER SOLUTIONS THERMODAN PEXIDAN HF PEXIDAN Advanced LSZH Thermoplastic Compounds Advanced LSZH Cross-Linkable Compounds XLPE Cross-Linkable Compounds Moisture Cure Technology SACO AEI

More information

Temperature rating. Printer information

Temperature rating. Printer information Wire and Harness ID Products TMS-SCE marker sleeves are designed to meet the wire and cable marking needs of manufacturers with high performance requirements. Made from durable, flame retarded, radiationcrosslinked

More information

MORE VALUE MORE BENEFITS MORE THAN YOU IMAGINE ÖLFLEX TRAY II ÖLFLEX TRAY II CY

MORE VALUE MORE BENEFITS MORE THAN YOU IMAGINE ÖLFLEX TRAY II ÖLFLEX TRAY II CY MORE VALUE MORE BENEFITS MORE THAN YOU IMAGINE ÖLFLEX TRAY II ÖLFLEX TRAY II CY GERMAN PRECISION ENGINEERING PROUDLY PRODUCED IN THE USA. The Lapp Group North American headquarters, located in Florham

More information

Traction Cable Radox 3 GKW

Traction Cable Radox 3 GKW General Properties : Excellent high temperature, low temperature, ozone and weathering resistance, zero halogen, flame retardant, solder iron resistant, easily strippable, flexible. Application : Single

More information

DualGuard Fluoropolymer Barrier FRP Duct. Composites USA. Fluoropolymer Barrier FRP Duct. A Critical Process Systems Group Company LISTED

DualGuard Fluoropolymer Barrier FRP Duct. Composites USA. Fluoropolymer Barrier FRP Duct. A Critical Process Systems Group Company LISTED DG TM DualGuard 2000 Fluoropolymer Barrier FRP Duct C U L LISTED US Fluoropolymer Barrier FRP Duct Composites USA A Critical Process Systems Group Company Worried about meeting Insurance Underwriter and

More information

DNVGL-CP-0399 Edition March 2016

DNVGL-CP-0399 Edition March 2016 CLASS PROGRAMME Type approval DNVGL-CP-0399 Edition March 2016 The electronic pdf version of this document, available free of charge from http://www.dnvgl.com, is the officially binding version. FOREWORD

More information

AFIREFENIX SZ1-K 0,6/1 kv PH120 (AS+)

AFIREFENIX SZ1-K 0,6/1 kv PH120 (AS+) Page 1 / 7 Construction and tests. Standards: UNE 211025 Compliance with the Low Voltage Directive (LVD): 2014/35 / EU Construction Products Regulation (CPR) - Regulation (EU) Nº 305/2011: Reaction to

More information

APPENDIX - L INTERNATIONAL RESIDENTIAL CODE ELECTRICAL

APPENDIX - L INTERNATIONAL RESIDENTIAL CODE ELECTRICAL This Appendix (2000 IRC Appendix-L) is produced, copyrighted, and maintained by the National Fire Protection Association Association, all rights reserved. Use of this Appendix is pursuant to license with

More information

STANDARD FOR FIRE RATED ROLLING DOOR ASSEMBLIES

STANDARD FOR FIRE RATED ROLLING DOOR ASSEMBLIES ANSI/DASMA 204-2004 AMERICAN NATIONAL STANDARD STANDARD FOR FIRE RATED ROLLING DOOR ASSEMBLIES Door & Access Systems Manufacturers Association, International Sponsor: 1300 Sumner Ave Cleveland, Ohio 44115-2851

More information

The Star Teck Extreme STE/STEX Series Connectors

The Star Teck Extreme STE/STEX Series Connectors The Star Teck Extreme STE/STEX Series Connectors Designed to stand up to the harshest and most corrosive environments. Three Generations of Improvements! Spin On, Star Teck, Star Teck Extreme Tray Cable

More information

BS EN : Measurements Of Smoke Density Of Electric Cables. WF Report Number. Date: 17 th November Test Sponsor:

BS EN : Measurements Of Smoke Density Of Electric Cables. WF Report Number. Date: 17 th November Test Sponsor: BS EN 61034-2: 2005 Measurements Of Smoke Density Of Electric Cables WF Report Number 177599 Date: 17 th November 2008 Test Sponsor: FTC Fabbrica Trentina Conduttori Srl 0249 Page 2 of 13 Bodycote warringtonfire

More information

Catalogue Power Cables

Catalogue Power Cables Catalogue Power Cables Conductores Tecnológicos S.A. www.contecsa.es Index of Cables Page Introduction 13 RV 14 RVMV 15 RVSV 16 RVFV 17 Conductores Tecnológicos S.A. 2 www.contecsa.es INTRODUCTION Power

More information

B C D. Strip Heaters. Channel Strip Heaters Ceramic Insulated. To order, call or shop online at omega.com SM

B C D. Strip Heaters. Channel Strip Heaters Ceramic Insulated. To order, call or shop online at omega.com SM Ceramic Insulated A Reliable Heat Source with Seamless Stainless Steel Sheath Flat Surface Mounting Installations Used in Hundreds of Industrial and Commercial Heating Applications Typical Applications

More information

B C D. Strip Heaters. Channel Strip Heaters Ceramic Insulated. To order, call or shop online at omega.com SM

B C D. Strip Heaters. Channel Strip Heaters Ceramic Insulated. To order, call or shop online at omega.com SM Ceramic Insulated A Reliable Heat Source with Seamless Stainless Steel Sheath Flat Surface Mounting Installations Used in Hundreds of Industrial and Commercial Heating Applications Typical Applications

More information

Caledonian Fire resistant Coaxial Cables

Caledonian Fire resistant Coaxial Cables Caledonian Fire resistant Coaxial Cables www.caledonian-cables.net www.addison-cables.com Fire resistant rg59 b/u Coaxial Cables RG59 B/U FR LSZH Sheath Fire Resistant Tape Copper Clad Steel/Bare Copper

More information

Flame Retardant EP/CPE POWER, CONTROL & INSTRUMENTATION CABLES

Flame Retardant EP/CPE POWER, CONTROL & INSTRUMENTATION CABLES Flame Retardant EP/CPE POWER, CONTROL & INSTRUMENTATION CABLES 37-754 FLAME RETARDANT EP/CPE TYPE TC OR TC-ER POWER CABLE Two Five Conductor + Ground (Two, Three & Four Conductor) 600 V Rated 90 C Conductor*

More information

STANDARDS INSTALLATION. Certificate No 077m

STANDARDS INSTALLATION. Certificate No 077m Certificate No 077m > Prysmian FP600 is a unique enhanced performance fire resistant power cable, designed specifically to meet the more onerous fire survival requirements now requested by regulators and

More information

BlazeMaster Fire Sprinkler Systems

BlazeMaster Fire Sprinkler Systems Engineered Polymers FACT SHEET The Lubrizol Corporation is the world leader in chlorinated polyvinyl chloride (CPVC) resins and compounds, which are trusted in various applications, including plumbing,

More information

PolyOne is a global polymer solutions provider with the ability to meet regulatory and product

PolyOne is a global polymer solutions provider with the ability to meet regulatory and product Product Description PolyOne is a global polymer solutions provider with the ability to meet regulatory and product specifications globally and offer the widest range of polymer-specific specialty colorant

More information

TABLE OF CONTENTS CHAPTER 1 GENERAL RULES CHAPTER 2 WIRING AND PROTECTION... 51

TABLE OF CONTENTS CHAPTER 1 GENERAL RULES CHAPTER 2 WIRING AND PROTECTION... 51 TABLE OF CONTENTS About This Textbook...xi How to Use the National Electrical Code... 1 Article 90 Introduction to the National Electrical Code... 7 90.1 Purpose of the NEC... 7 90.2 Scope of the NEC...

More information

PLSRR Heat Trace Cable Data Sheet

PLSRR Heat Trace Cable Data Sheet PLSRR Heat Trace Cable Data Sheet PLSRR is self-regulating heat cable that can be used for roof / gutter heating pipe tracing. The cable features a flexible, UV-stabilized thermoplastic elastomer overjacket

More information

9/7/2010. Chapter , The McGraw-Hill Companies, Inc. AND BONDING. 2010, The McGraw-Hill Companies, Inc.

9/7/2010. Chapter , The McGraw-Hill Companies, Inc. AND BONDING. 2010, The McGraw-Hill Companies, Inc. Chapter 1 GROUNDING AND BONDING 1 Proper grounding practices protect people from the hazards of electric shock and ensure the correct operation of overcurrent protection devices. Grounding is the intentional

More information

BS FP600 achieves the maximum 120 minute rating under the BS test conditions, which is required for fire fighting applications.

BS FP600 achieves the maximum 120 minute rating under the BS test conditions, which is required for fire fighting applications. FIRE RESISTANT CABLES FP600 FIRE RESISTANT CABLES FP600 BS7346-6 FP600 > Prysmian FP600 is a unique enhanced performance fire resistant power cable, designed specifically to meet the more onerous fire

More information

2017 NEC Significant Code Changes Part 3

2017 NEC Significant Code Changes Part 3 2017 NEC Significant Code Changes Part 3 Eight (8) Continuing Education Hours Wisconsin Department of Safety and Professional Services (DSPS) Course Approval #18959 Approved Continuing Education for Wisconsin

More information

Installation Manual. Vent Kit for Condensing Tankless Gas Water Heater

Installation Manual. Vent Kit for Condensing Tankless Gas Water Heater Installation Manual NORITZ AMERICA CORPORATION Vent Kit for Condensing Tankless Gas Water Heater Model: N-FlexKit2"-35 Applicable Model NRC663-FSV Potential dangers from accidents during installation and

More information

Tyco Electronics Solar Identification Labels

Tyco Electronics Solar Identification Labels Tyco Electronics Solar Identification Labels 2010 Tyco Electronics Corporation. All Rights Reserved TE logo and Tyco Electronics are trademarks. Other products, logos and Company names mentioned herein

More information

1993 Specifications CSJ SPECIAL SPECIFICATION ITEM Impermeable Liner

1993 Specifications CSJ SPECIAL SPECIFICATION ITEM Impermeable Liner 1993 Specifications CSJ 0128-01-085 SPECIAL SPECIFICATION ITEM 5327 Impermeable Liner 1. Description. This Item shall govern for the furnishing and installation of the impermeable liner (geomembrane) shown

More information