Caledonian Fire resistant Coaxial Cables
|
|
- Sophie Fletcher
- 5 years ago
- Views:
Transcription
1 Caledonian Fire resistant Coaxial Cables Fire resistant rg59 b/u Coaxial Cables RG59 B/U FR LSZH Sheath Fire Resistant Tape Copper Clad Steel/Bare Copper P/FP Insulation Copper ire Braid Screen application The cables are designed for CCTV, security, smoke detection and evacuation monitoring applications, where continued functionality is required during a fire situation. Due to the zero halogen low smoke construction, this cable is ideal for use in public, commercial and industrial environments. standards Basic design to MIL-C-17 Fire PerFOrManCe System Flame Retardance (Single Vertical ire Test) (Vertically-mounted bundled wires & cable test) IC ; BS 6387 CZ; DIN VD (F180); CI 20-36/2-1; SS299-1; NBN C (cat. F3); DIN , 30 depending on lay system N ; IC ; BS N ; VD ; NBN C (cat. F1); NF C (C2); CI 20-35/1-2; N *; DIN VD * N (cat. C); IC ; BS N ; VD ; NBN C (cat. F2); NF C (C1); CI 20-22/3-4; N *; DIN VD IC ; N ; DIN VD ; CI 20-37/2-1 ; BS * No Corrosive Gas mission IC ; N ; DIN VD ; CI 20-37/2-2 ; BS * Minimum Smoke mission IC &2; N &2; DIN VD &2; CI 20-37/3-1&2; N &2*; BS &2* No Toxic gases NS ; NF C note: asterisk * denotes superseded standard. ADDISON 25
2 ADDISON CABL CONSTRUCTION Conductors: Copper clad steel, solid according to IC class 1. Insulation: P wrapped with fire resistant silicone rubber compound type I2 as per BS or fluoropolymer(fp) compound. Binder: Glass tape Overall Screen: Plain copper wire braid Outer Sheath: Thermoplastic LSZH compound type LTS3 as per BS (Thermosetting LSZH compound type S2-S4 as per BS can be offered.). UV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be offered as option. Physical AND THRMAL PROPRTIS Temperature range during operation (fixed state): -30 C C Temperature range during installation (mobile state): -5ºC - +60ºC Minimum bending radius: 8 x Overall lectrical Properties Impedance 75±5Ω Capacitance 67 nf/km Velocity ratio(%) 66 Insulation resistance >2000 Mohm.Km Shield coverage 95% DC resistance Inner conductor 158 Ω/km Outer conductor 9.0 Ω/km Attenuation Frequency(MHz) Attenuation (db/100 m) Attenuation (db/100ft) Caledonian
3 Caledonian Fire resistant Coaxial Cables Return Loss Frequency(MHz) Return Loss (db) MHz >31dB MHz >28dB MHz >24dB CONSTRUCTION PARAMTRS Cable Code Conductor Insulation Screen No.x Overall Approx. eight mm mm No. x mm mm kg/km RG59 B/U FR 0.58 ± ± 0.10 m 120 x ± /500V MIL-C-17 N Rated Voltage Standard IC 60331/BS 6387 NF C (C1) IC /N NF C (C2) IC /N Flame Retardancy Zero NS /NF C Low Toxicity IC N /3 NF C Low Corrosivity IC &2 N &2/NF C32-07 Low Smoke mission IC N DIN Functional Integrity ADDISON 27
4 ADDISON Fire resistant rg6 a/u Coaxial Cables RG6 A/U FR Aluminium Foil Screen2 Aluminium Foil Screen1 P/FP Insulation Solid Bare Copper Fire Resistant Tape LSZH Sheath application The cables are designed for CCTV, security, smoke detection and evacuation monitoring applications, where continued functionality is required during a fire situation. Due to the zero halogen low smoke construction, this cable is ideal for use in public, commercial and industrial environments. standards Basic design to MIL-C-17 Fire PerFOrManCe System Flame Retardance (Single Vertical ire Test) (Vertically-mounted bundled wires & cable test) IC ; BS 6387 CZ; DIN VD (F180); CI 20-36/2-1; SS299-1; NBN C (cat. F3); DIN , 30 depending on lay system N ; IC ; BS N ; VD ; NBN C (cat. F1); NF C (C2); CI 20-35/1-2; N *; DIN VD * N (cat. C); IC ; BS N ; VD ; NBN C (cat. F2); NF C (C1); CI 20-22/3-4; N *; DIN VD IC ; N ; DIN VD ; CI 20-37/2-1 ; BS * No Corrosive Gas mission IC ; N ; DIN VD ; CI 20-37/2-2 ; BS * Minimum Smoke mission IC &2; N &2; DIN VD &2; CI 20-37/3-1&2; N &2*; BS &2* No Toxic gases NS ; NF C note: asterisk * denotes superseded standard. 28 Caledonian
5 Caledonian Fire resistant Coaxial Cables CABL CONSTRUCTION Conductors: Bare copper copper wire, solid according to IC class 1. Insulation: Foamed P wrapped with fire resistant silicone rubber compound type I2 as per BS or fluoropolymer(fp) compound. Binder: Glass tape Overall Screen: AL foil(100%)+al braid (70%) Outer Sheath: Thermoplastic LSZH compound type LTS3 as per BS (Thermosetting LSZH compound type S2-S4 as per BS can be offered.). UV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be offered as option. Physical AND THRMAL PROPRTIS Temperature range during operation (fixed state): -30 C C Temperature range during installation (mobile state): -5ºC - +60ºC Minimum bending radius: 8 x Overall lectrical Properties Impedance 75±5Ω Capacitance Velocity ratio(%) 82 Insulation resistance 54 nf/km >5000 Mohm.Km Shield coverage AL foil(100%)+al 70% DC resistance Inner conductor Outer conductor Attenuation 23.1 Ω/km 31 Ω/km Frequency(MHz) Attenuation (db/100 m) Attenuation (db/100ft) ADDISON 29
6 ADDISON Return Loss Frequency(MHz) Return Loss (db) >28dB >24dB >22dB CONSTRUCTION PARAMTRS Cable Code Conductor Insulation Screen No.x Overall Approx. eight mm mm No. x mm mm kg/km RG6 A/U FR ± x ± /500V MIL-C-17 N Rated Voltage Standard IC 60331/BS 6387 NF C (C1) IC /N NF C (C2) IC /N Flame Retardancy Zero NS /NF C Low Toxicity IC N /3 NF C Low Corrosivity IC &2 N &2/NF C32-07 Low Smoke mission IC N DIN Functional Integrity 30 Caledonian
7 Caledonian Fire resistant Coaxial Cables Fire resistant rg6 QUaD Coaxial Cables RG6 QUAD FR LSZH Sheath Al-maylar Tape2 Aluminium Braid1 P/FP Insulation Solid Bare Copper Fire Resistant Tape Aluminium Braid3 Al-maylar Tape4 application The cables are designed for CCTV, security, smoke detection and evacuation monitoring applications, where continued functionality is required during a fire situation. Due to the zero halogen low smoke construction, this cable is ideal for use in public, commercial and industrial environments. standards Basic design to MIL-C-17 Fire PerFOrManCe System Flame Retardance (Single Vertical ire Test) (Vertically-mounted bundled wires & cable test) IC ; BS 6387 CZ; DIN VD (F180); CI 20-36/2-1; SS299-1; NBN C (cat. F3); DIN , 30 depending on lay system N ; IC ; BS N ; VD ; NBN C (cat. F1); NF C (C2); CI 20-35/1-2; N *; DIN VD * N (cat. C); IC ; BS N ; VD ; NBN C (cat. F2); NF C (C1); CI 20-22/3-4; N *; DIN VD IC ; N ; DIN VD ; CI 20-37/2-1 ; BS * No Corrosive Gas mission IC ; N ; DIN VD ; CI 20-37/2-2 ; BS * Minimum Smoke mission IC &2; N &2; DIN VD &2; CI 20-37/3-1&2; N &2*; BS &2* No Toxic gases NS ; NF C note: asterisk * denotes superseded standard. ADDISON 31
8 ADDISON CABL CONSTRUCTION Conductors: Copper clad steel, solid according to IC class 1. Insulation: Foamed P wrapped with fire resistant silicone rubber compound type I2 as per BS or fluoropolymer(fp) compound. Binder: Glass tape Overall Screen: Screen1: Al-maylar Tape 25% Screen2: Aluminium Braid Screen3: Al-maylar Tape 25% Screen4: Aluminium Braid Outer Sheath: Thermoplastic LSZH compound type LTS3 as per BS (Thermosetting LSZH compound type S2-S4 as per BS can be offered.). UV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be offered as option. Physical AND THRMAL PROPRTIS Temperature range during operation (fixed state): -30 C C Temperature range during installation (mobile state): -5ºC - +60ºC Minimum bending radius: 8 x Overall lectrical Properties Impedance 75±5Ω Capacitance Velocity ratio(%) 82 Insulation resistance 54 nf/km Shield coverage 60% Max.conductor resistance Attenuation >5000 Mohm.Km 24.1 Ω/km Frequency(MHz) Attenuation (db/100 m) Attenuation (db/100ft) Caledonian
9 Caledonian Fire resistant Coaxial Cables Return Loss Frequency(MHz) Return Loss (db) >28dB >24dB >22dB CONSTRUCTION PARAMTRS Cable Code Conductor Insulation Screen2 No.x Screen4 No.x Overall Approx. eight mm mm No. x mm No. x mm mm kg/km RG6 QUAD FR ± x x ± /500V MIL-C-17 N Rated Voltage Standard IC 60331/BS 6387 NF C (C1) IC /N NF C (C2) IC /N Flame Retardancy Zero NS /NF C Low Toxicity IC N /3 NF C Low Corrosivity IC &2 N &2/NF C32-07 Low Smoke mission IC N DIN Functional Integrity ADDISON 33
10 ADDISON Fire Resistant RG11 A/U Coaxial Cables RG11 A/U FR Plain Copper ire Braid P/FP Insulation Tinned Copper Fire Resistant Tape LSZH Outer Sheath APPLICATION The cables are designed for CCTV, security, smoke detection and evacuation monitoring applications, where continued functionality is required during a fire situation. Due to the zero halogen low smoke construction, this cable is ideal for use in public, commercial and industrial environments. Standards Basic design to MIL-C-17 FIR PRFORMANC System Flame Retardance (Single Vertical ire Test) (Vertically-mounted bundled wires & cable test) IC ; BS 6387 CZ; DIN VD (F180); CI 20-36/2-1; SS299-1; NBN C (cat. F3); DIN , 30 depending on lay system N ; IC ; BS N ; VD ; NBN C (cat. F1); NF C (C2); CI 20-35/1-2; N *; DIN VD * N (cat. C); IC ; BS N ; VD ; NBN C (cat. F2); NF C (C1); CI 20-22/3-4; N *; DIN VD IC ; N ; DIN VD ; CI 20-37/2-1 ; BS * No Corrosive Gas mission IC ; N ; DIN VD ; CI 20-37/2-2 ; BS * Minimum Smoke mission IC &2; N &2; DIN VD &2; CI 20-37/3-1&2; N &2*; BS &2* No Toxic gases NS ; NF C Note: Asterisk * denotes superseded standard. 34 Caledonian
11 Caledonian Fire resistant Coaxial Cables CABL CONSTRUCTION Conductors: Tinned copper copper wire, stranded according to IC class 2. Insulation: Low density P wrapped with fire resistant silicone rubber compound type I2 as per BS or fluoropolymer(fp) compound. Binder: Glass tape Overall Screen: Plain copper wire braid Outer Sheath: Thermoplastic LSZH compound type LTS3 as per BS (Thermosetting LSZH compound type S2-S4 as per BS 7655:section 2.6 can be offered.). UV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be offered as option. Physical AND THRMAL PROPRTIS Temperature range during operation (fixed state): -30 C C Temperature range during installation (mobile state): -5ºC - +60ºC Minimum bending radius: 8 x Overall lectrical Properties Impedance 75±5Ω Capacitance Velocity ratio(%) 66 Insulation resistance Shield coverage 97% DC resistance Inner conductor Outer conductor Attenuation 67 nf/km >2000 Mohm.Km 20.5 Ω/km 4.5 Ω/km Frequency(MHz) Attenuation (db/100 m) Attenuation (db/100ft) ADDISON 35
12 ADDISON Return Loss Frequency(MHz) Return Loss (db) MHz >30dB MHz >27dB MHz >25dB CONSTRUCTION PARAMTRS Cable Code Conductor Insulation Screen No.x Overall Approx. eight mm mm No. x mm mm kg/km RG11 A/U FR 7 x ± x ± /500V MIL-C-17 N Rated Voltage Standard IC 60331/BS 6387 NF C (C1) IC /N NF C (C2) IC /N Flame Retardancy Zero NS /NF C Low Toxicity IC N /3 NF C Low Corrosivity IC &2 N &2/NF C32-07 Low Smoke mission IC N DIN Functional Integrity 36 Caledonian
Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design.
ADDISON Flame Retardant RG59 B/U Coaxial cables Plain copper wire braid PE Solid Bare Copper PVC Outer Sheath APPLICATION The cables are designed for CCTV, security, smoke detection and evacuation monitoring
More informationCaledonian Flame Retardant Coaxial Cables
Caledonian Flame Retardant Coaxial Cables www.caledonian-cables.co.uk www.addison-cables.com Flame Retardant RG59 Coaxial cables LSZH Outer Sheath Tinned Copper Braid Aluminium+polyester/Aluminium Tape
More information600/1000V XLPE Insulated, LSZH Sheathed, Double steel tape Armoured Power Cables (3 Cores)
Caledonian Flame Retardant Power & Control Cables www.caledonian-s.co.uk www.addison-s.com 600/1000V XLPE Insulated, LSZH Sheathed, Double steel tape Armoured Power Cables (3 Cores) FTX400 1RZ1MZ1-R (CU/XLPE/LSZH/DSTA/LSZH
More informationIEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission
ADDISON Flame Retardant CAT5e Data Cables FTX-CAT5e U/UTP4P24 FTX-CAT5e f/utp4p24 FTX-CAT5e sf/utp4p24 LSZH Outer Aluminium/Polyester Tape Solid Copper Conductor PE Insulation Tinned Copper Drain Wire
More informationIEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission
Flame Retardant RS485 Databus Cables Copper Wire Braid(optional) Individual AL/Polyester Tape(optional) Foam PE/Foam skin PE. Stranded Tinned Copper AL/Polyester Tape With Tinned Copper Drain Wire LSZH
More informationCaledonian fire Resistant signal & Data cables
fire Resistant signal & Data cables www.addison-tech.com fire Resistant Rs485 Databus cables Copper Wire Braid(optional) Individual AL/Polyester Tape(optional) Mica Glass Tape+PE/PE+Silicone Rubber Insulation
More information600/1000V SR Insulated Flexibles Control Cables (2-4 Cores & Multicores)
600/1000V SR Insulated Flexibles Control Cables (2-4 Cores & Multicores) FFX400 1SZ1-R(PH60)(CU/SR/LSZH 600/1000V Class 2) FFX400 1SZ1-F(PH60)(CU/SR/LSZH 600/1000V Class 5) Silicone Rubber Insulation Plain
More informationFlame Retardant Overall Screened Instrumentation Cables (multicore)
Flame Retardant Overall Screened Instrumentation Cables (multicore) RE-2X(St)H RE-2X(St)HSWAH LSZH Outer Sheath Tinned Copper Drain Wire LSZH Inner Sheath XLPE Insulation Plain Annealed Copper Aluminium/polyester
More information600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (Multicore)
600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (Multicore) FGD400 1RV-R (CU/XLPE/PVC 600/1000V Class ) FGD400 1RVMV-R (CU/XLPE/PVC/SWA/PVC 600/1000V Class ) PVC Outer Sheath Plain Annealed
More informationBS /1000V XLPE Insulation LSZH Sheath Cables
BS 8573 600/1000V XLPE Insulation LSZH Sheath Cables Caledonian www.addison-cables.com Company Profile Caledonian & Addison, branded under Caledoniea & Addimax, established in 1978, offers one of the most
More informationPRODUCT CATALOGUE Norröna
PRODUCT CATALOGUE Norröna WWW.SCANKAB.COM Table of contents MARINE AND OFFSHORE CABLES 1 TOXFREE XZ1-K (AS) - 0.6/1 kv 1 TOXFREE MARINE XO2TCuZ1-K (AS) - 150/250 V 5 4x2xAWG 24/1 CAT6 S/FTP LSZH-SHF1 -
More informationFIRE RESISTANT CABLES
Conducting Value The Last Cable Standing FIRE RESISTANT CABLES 100/7b ISO 9001:2008 Certificate No. CS1-249 MANAGEMENT SYSTEMS Assessed to ISO 9001:2008 Cert/LPCB ref. 217 GOST ISO 9001-2011 (ISO 9001:2008)
More informationCaledonian. FIREFLIX ire Resistant Coaxial Cables
Caledonian FIREFLIX ire Resistant Coaxial Cables table OF COntents Fire resistant Coaxial Cables Fire Resistant RG59 B/U coaxial cables...25 Fire Resistant RG6 A/U coaxial cables...28 Fire Resistant RG6
More informationPhotovoltaic Cables EN H1Z2Z2-K
Photovoltaic Cables EN 50618 H1Z2Z2-K COMPANY PROFILE Caledonian, established in 1978, offers one of the most complete lines of fiber and copper cabling system solutions with over hundreds of different
More informationMulti-Core Fire Resistant Cable
Fire Resistant Cables / Multi-Core Fire Resistant Cable Approved to UL 444, Zeta ZFP series cables have received UL approval for standard applications. Standards Alarm Cable Z UL 444 Approval CMH Rated
More informationHigh Performance LSZH Fire Resistant Cable
High Performance LSZH Fire Resistant Cable www.cavicel.com 104/2 FIRECEL SR 114H is the long and well established CAVICEL fire resistant cable in the market, since many years. These cables are third party
More informationFirecel Safety Cables
103/7 Firecel Safety Cables Low Smoke - Zero Halogen www.cavicel.com Firecel Safety Cables Low Smoke - Zero Halogen Over the last 30 years CAVICEL has developped a deep experience in studying, designing
More informationIntroduction.
Introduction The safety of occupants and users of public, commercial and industrial premises is of paramount importance. One important safety feature is the appropriate use of fire performance cables for
More informationSPECIAL ELECTRICAL AND OPTICAL CABLES
SPECIAL ELECTRICAL AND OPTICAL CABLES INTRODUCTION The new high-speed trains and the sensible increase of the traffic, with congested lines, is the result of the latest development of the rail sector.
More informationCompact Module. Category 6A FTP Cabling System 1.1
Updated 24/09/12 Compact Module Cat 6A performance Suitable for 10-Gigabit Ethernet Ultra-slimline design Euro style module Interchangeable with other Euro Modules and blanks Individually QA tested Easy
More informationFiretuf Cables ZERO HALOGEN, LOW SMOKE (0HLS ) CABLE
Firetuf Cables ZERO HALOGEN, LOW SMOKE (0HLS ) CABLE Draka, the world s mo When it comes to specifying fire performance cables, zero halogen building wires and power cables, you have to choose products
More informationFiretuf Cables ZERO HALOGEN, LOW SMOKE (0HLS ) CABLE
Firetuf Cables ZERO HALOGEN, LOW SMOKE (0HLS ) CABLE Draka, the world s most trusted cable brand When it comes to specifying fire performance cables, zero halogen building wires and power cables, you have
More informationCatalogue Telecommunication Cables INTRODUCCIÓN
Catalogue Telecommunication Cables INTRODUCCIÓN Conductores Tecnológicos S.A. www.contecsa.es Index of Cables Page Introduction 3 EAP / EAP-R 4 EAPSP / EAPSP-R 5 ISP / ICP 6 Conductores Tecnológicos S.A.
More informationCABLES FOR ALARM AND SAFETY SYSTEMS
CABLES FOR ALARM AND SAFETY SYSTEMS 2 IT S ALL ABOUT RELIABILITY. It is always important to choose high quality cables, especially when it comes to alarms and safety systems. Even small and seemingly insignificant
More informationCore identification code. J-YY...BD Indoor Cable. J-YY...BD Indoor Cable. VDE 0815 Mutual capacitance. J-YY...BD Indoor Cable. Cu conductor 0.
Indoor cables J-YY...BD Indoor J-Y(ST)Y..LG Indoor Comparable products UNITRONIC J-2Y(ST)Y...ST III BD see page 271 Indoor telephone cables transmit analogue or digital signals In news and communication
More informationPower Cables. Introduction 3 RV 4 RVMV 5 RVSV 6 RVFV 7. ELECWIRES 2 Page
Power Cables Power Cables Page Introduction 3 RV 4 RVMV 5 RVSV 6 RVFV 7 ELECWIRES 2 www.elecwires.es INTRODUCTION Power Cables Power cables for electrical installations, domestic & industrial, specifically
More informationFire alarm cables. for highest safety requirements TRADITION INNOVATION PASSION
Fire alarm cables for highest safety requirements TRADITION INNOVATION PASSION Datwyler Datwyler Cabling Solutions is an internationally operating company with its headquarters in Switzerland and affiliates
More informationINTRODUCTION. Our diverse range of world-class Specialty Insulated Wires and Cablesinclude: LV Cables -
MARINE CABLES Your Power Partner on the Seas INTRODUCTION We, a member of the Al-Bahja Group of Companies, are an ISO:900:2008 BASEC, UK certified integrated quality producer of LV and MV Cables, Wires&
More informationTable of Contents. TELE-FONIKA KABLE SA (DMCC Branch). 4 TELE-FONIKA Kable Group 6 FLAME-X 950 SERIES 1 11 FLAME-X 950 SERIES 2
FLAME-X 950 TELE-FONIKA KABLE SA (DMCC Branch). Table of Contents is the Regional Middle East Sales Office of Tele-Fonika Kable S.A. from Poland, 4-th largest manufacturer of electric cables and wires
More informationCatalogue Power Cables
Catalogue Power Cables Conductores Tecnológicos S.A. www.contecsa.es Index of Cables Page Introduction 13 RV 14 RVMV 15 RVSV 16 RVFV 17 Conductores Tecnológicos S.A. 2 www.contecsa.es INTRODUCTION Power
More informationTelecommunication Cables
Telecommunication Cables Telecommunication Cables Introduction 3 EAP / EAP-R 4 EAPSP / EAPSP-R 5 ISP / ICP 6 Page ELECWIRES 2 www.elecwires.es INTRODUCCIÓN Telecommunication Cables Telephone cables suitable
More informationShipboard & Offshore Cables
Shipboard & Offshore Cables Shipboard & Offshore Cables Páge Introduction 3 Power Cables XL / XL-FR 5 XC4L / XC4L-FR 6 XLC4L / XLC4L-FR 7 Instrumentation cables XHL / XHL-FR 8 XOL / XOL-FR 9 XHC4L / XHC4L-FR
More informationCatalogue. Instrumentation & Control Cables
Catalogue Instrumentation & Control Cables Conductores Tecnológicos S.A. www.contecsa.es Index of Cables Page Introduction 3 Instrumentation VOV 4 VHOV 5 VOVMV 6 VHOVMV 7 Control RV 8 RZ1C3Z1 9 Conductores
More informationfire resistant cables
Building Technology fire resistant cables Special electrical and optical cables www.tecnikabel.com Special electrical and optical cables 2 INTRODUCTION Structured cabling solutions. Tecnikabel can provide
More informationFIRE PERFORMANCE CABLE
FIRE PERFORMANCE CABLE Manufactured to BS 7629-1 Table 1 Plain Annealed Copper Conductors / Silicone Rubber Insulated / Double Layer of Aluminium/ Polyester Laminated Tapes / Circuit Protective Conductor
More informationAFIREFENIX SZ1-K 0,6/1 kv PH120 (AS+)
Page 1 / 7 Construction and tests. Standards: UNE 211025 Compliance with the Low Voltage Directive (LVD): 2014/35 / EU Construction Products Regulation (CPR) - Regulation (EU) Nº 305/2011: Reaction to
More informationBS EN :2004. Test On Electric And Optical Fibre Cables Under Fire Conditions. WF Report Number. Date: 14 th November 2008.
BS EN 60332-1-2:2004 Test On Electric And Optical Fibre Cables Under Fire Conditions WF Report Number 177603 Date: 14 th November 2008 Test Sponsor: FTC Fabbrica Trentina Conduttori Srl 0249 Page 2 of
More informationRolling Stock Cables.
Rolling Stock Cables www.caledonian-cables.co.uk www.addison-cables.com & Addison, established in 1978, produced a wide range of copper and fiber optic cables for communication, power and electronics in
More informationENHANCED FIRE PERFORMANCE CABLE
FIRE PERFORMANCE CABLE Manufactured to BS 7629-1 Table 1 Plain Annealed Copper Conductors / Silicone Rubber Insulated / Glass Fibre Tape / Tinned Copper Circuit Protective Conductor / Double Layer of Copper/Polyester
More informationThe Quality Connection. BETAflam Fire Resistant Safety Cables
The Quality Connection BETAflam Fire Resistant Safety Cables BETAflam Contact Your personal customer number To offer you a more efficient service, we kindly ask you to mention your personal customer number
More informationCable technology for highest safety requirements
Cable technology for highest safety requirements Daetwyler We are a provider of high-grade quality system solutions and services in the areas of structured data cabling, telecom carriers, safety cabling,
More informationTHE INNOVATIVE CABLE PRODUCER INSTRUMENTATION CABLES FOR THE INDUSTRY - AND PLANT CONSTRUCTION
THE INNOVATIVE CABLE PRODUCER INSTRUMENTATION CABLES FOR THE INDUSTRY - AND PLANT CONSTRUCTION About Us 60 Countries Using Birtaş Cable Products As of 2014 Birtaş Kablo is exporting its products to 60
More informationSAS Security and Alarm Safety Cables
CABLES Security and Alarm Safety Cables Security and Alarm Safety Cables LOW SMOKE ZERO HALOGEN The right range of cables for modern building installations e-catalogue 203/4 Flexible solutions for commercial,
More informationF1202 TRACE HEATING. Road & Ramp
Trace Heating Specialists Road & Ramp ROAD & RAMP HEATING ESH Trace Heating Ltd provide a comprehensive range of products to prevent the settlement of snow and formation of ice on roads, ramps and stairs.
More informationTraction Cable Radox 3 GKW
General Properties : Excellent high temperature, low temperature, ozone and weathering resistance, zero halogen, flame retardant, solder iron resistant, easily strippable, flexible. Application : Single
More informationIEC UNE DESIGN. 1. Conductor. 2. Insulation. Cross-linked polyethylene (XLPE) 3. Outer sheath. Flexible PVC, black colour.
67 POWERFLEX RV-K POWERFLEX RV-K Industrial flexible cable for power transmission. 1 IEC 60502-1 - UNE 21123-2 DESIGN 1. Conductor 2 Electrolytic copper, class 5 (flexible), based on EN 60228 and IEC 60228.
More informationDouble insulated, electron-beam cross-linked, halogen free photovoltaic wire sunlight resistant. Single conductor, flame retardant insulation.
Technical Data Sheet BETAflam Solar 125 flex UL 4703 Description Double insulated, electron-beam cross-linked, halogen free photovoltaic wire sunlight resistant. Single conductor, flame retardant insulation.
More informationOIL & GAS INDUSTRY OTHER INDUSTRIES
For ATEX Areas OIL & GAS INDUSTRY OTHER INDUSTRIES OIL & GAS INDUSTRY POTENTIALLY HAZARDOUS Class I GASES VAPORS LIQUIDS Petrosumsave Zone 0 An area in which an explosive mixture is continuously present,
More informationCATEGORY 6A FTP RJ45 SOLUTION
CATEGORY 6A FTP RJ45 SOLUTION Clipsal titanium Patch Cord Clipsal titanium LSZH Patch Cord Clipsal titanium Keystone Jacks Clipsal titanium Modular Jacks Clipsal titanium Patch Panels Clipsal titanium
More informationGCRG. Multi Loose Tube Cables Universal Indoor / Outdoor A/I-DQ(ZN)BH Improved Rodent Protection v7.0. Ordering Information.
GCRG Multi Loose Tube Cables Universal Indoor / Outdoor A/I-DQ(ZN)BH Improved Rodent Protection 05-05-7 v7.0 Ordering Information Belden Part Numbers Fibre Description / count 4 8 8 4 30 36 6.5/5-OM GCRG04
More informationPHOTOVOLTAIC CABLES. Photovoltaic Cable 2000V/1500V Photovoltaic Cable 2000V/1000V
PHOTOVOLTAIC CABLES PHOTOVOLTAIC CABLES INDEX n AmerSol Dual-Certified (UL / ETL) Photovoltaic Cable 2000V/1500V....................... 2-3 n AmerSol Dual-Certified (UL / ETL) Photovoltaic Cable 2000V/1000V.......................
More informationTotal Fire Solutions. Includes BS 8519 and the updated BS :
Total Fire Solutions Includes BS 8519 and the updated BS 5266-1:2011 www.aeicables.co.uk Introduction: Total Fire Solutions Power and control cable systems for life safety and fire-fighting applications
More informationSingle core cables with reduced wall thickness
Product description: RADOX 4 GKW -AX 1800V M Nominal voltage: Hazard level: Single core cables with reduced wall thickness 1800 / 3000 V AC M (extra low temperature, extra oil and extra fuel resistant)
More informationGUCN. Central Loose Tube Cables Universal Indoor / Outdoor - Corrugated Steel Tape Armor (CST) A/I-DQ(ZN)(SR)H Full Rodent Protection v13.
GUCN Central Loose Tube Cables Universal Indoor / Outdoor - Corrugated Steel Tape Armor (CST) A/I-DQ(ZN)(SR)H Full Rodent Protection 07-07-05 v3.0 Ordering Information Belden Part Numbers Fibre Description
More informationCORFLEX. TYPE MC-HL & MV-105 or MC-HL OIL & GAS CABLES
CORFLEX TYPE MC-HL & MV-105 or MC-HL OIL & GAS CABLES INDEX Instrumentation Cables - Pairs and Triads (0V*)... 2 - The Original MC-HL Technology In 1958 Canada Wire and Cable, which s now part of Nexans,
More informationS Low loss coax cables with foamed PE
S Low loss coax cables with foamed PE Cable design Electrical cable data Impedance () 50 Capacitance 82 pf/m Velocity of signal propagation 82 % of the speed of light Epsilon r 1.5 Signal delay 4.1ns/m
More informationCMZH Low Smoke 0-Halogen Flame- Retardant Mass Transit Tag
STANDARD COLOR CMZH Low Smoke 0-Halogen Flame- Retardant Mass Transit Tag TECHNICAL DATA SHEET Revision Number. 1 Last Edited 9. januar 2019 OTHER COLORS MATERIAL Flat band cross linked polyolefin. OPERATING
More informationFlame Retardant EP/CPE POWER, CONTROL & INSTRUMENTATION CABLES
Flame Retardant EP/CPE POWER, CONTROL & INSTRUMENTATION CABLES 37-754 FLAME RETARDANT EP/CPE TYPE TC OR TC-ER POWER CABLE Two Five Conductor + Ground (Two, Three & Four Conductor) 600 V Rated 90 C Conductor*
More informationHavells Fire Survival Cables
Fire Survival Cables Designed for Critical Installation of National Importance Airports / Thermal Power Plants Metro Rail Projects / Rail Terminals / Nuclear Interstate Bus Terminals / Installation Prone
More informationTitle: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards
Change History Date Description of Change Pages / Sections Modified Change Approver Initials 8/1/17 Updated section on Manufacturers 3 1. 6/15/16 Updated division section from 16120 to 26 05 00, - mgl44
More informationBraided Sleeving. Mechanical Protection Electrical Insulation Thermal and Fire Insulation Electromagnetic Shielding
2017 Supplier of choice for Harness Components Aerospace Defence Energy Commercial Marine Motorsport Braided Sleeving Powerful Solutions for Protection Mechanical Protection Electrical Insulation Thermal
More informationCompany Profile. We are dedicated to providing our customers competitive price and excellent service.
1 Company Profile Hangzhou Kingtone Electronics Co., Limited is a Chinese wire & cable manufacturer specializing in manufacturing Coaxial Cable, Lan Cable, Alarm/Security Cable, Power Cable, Speaker Cable
More informationData sheet OpDAT universal cable 1x24 OM4 - bend insensitive
Illustrations Principle diagram Page 1/7 Product specification installation cable U-DQ(ZN)BH universal fiber optic cable for indoors/outdoors with central or stranded loose tube bend insensitive fiber
More informationFIRE RESISTANT CABLES FP200 GOLD
FIRE RESISTANT CABLES FP200 GOLD FIRE RESISTANT CABLES FP200 GOLD BS7629-1 FP200 GOLD Clause 26.2 > The original highly durable and dressable, easy to terminate and install fire resistant cable. Approved
More informationWire and Cable. For more information on these Tyco Electronics products, visit the following website:
26 Wire and Cable Raychem High Performance Wire and Cable....26-2 to 26-4 Madison Cable Products...................26-5 to 26-7 Reference the following cables in Section 15 of this catalog: Premises Networking
More informationSTANDARDS INSTALLATION. Certificate No 077m
Certificate No 077m > Prysmian FP600 is a unique enhanced performance fire resistant power cable, designed specifically to meet the more onerous fire survival requirements now requested by regulators and
More informationCORFLEX TYPE MC-HL POWER, CONTROL & INSTRUMENTATION CABLES
CORFLEX TYPE MC-HL POWER, CONTROL & INSTRUMENTATION CABLES CORFLEX TYPE MC-HL POWER, CONTROL & INSTRUMENTATION CABLES INDEX Corflex MC-HL Instrumentation - Pairs and Triads (0V*)... 1 - CORFLEX Cables
More informationCIR CRUSH & IMPACT RESISTANT ARCTIC GRADE OIL & GAS CABLES
CIR CRUSH & IMPACT RESISTANT ARCTIC GRADE OIL & GAS CABLES Gexol CIR ARCTIC GRADE (AG) Crush and Impact Resistant Without External Armoring Passes the same stringent crush and impact testing required by
More informationCIR AG Power Cables. CIR AG Control Cable. CIR Type VFD Cable. CIR AG Ratings & Approvals. n UL Listed as Type TC-ER n UL Listed as TC-ER-HL (E123629)
Gexol CIR ARCTIC GRADE (AG) Crush and Impact Resistant Without External Armoring Passes the same stringent crush and impact testing required by UL 2225 for Type MC-HL n Shortest Lead Times Standard 8-10
More informationCopper LAN cable. This specification describes the general requirements for AMP NETCONNECT* copper LAN cable.
Product Specification 108-93018 25/Aug/2011 Rev H Copper LAN cable 1. SCOPE 1.1. Content This specification describes the general requirements for AMP NETCONNECT* copper LAN cable. 2. APPLICABLE DOCUMENTS
More informationUV RESISTANT ACCORDING TO HD 605 RULE
UV RESISTANT ACCORDING TO HD 605 RULE Faced with increasingly frequent requirements to install outdoor wiring for data and signals, we further developed a special range of cables called: BLUE TOP LINE
More informationOFFSHORE CABLES. Top Cable Central Headquarters. Leonardo Da Vinci, number Rubí (Barcelona) Spain
Top Cable Central Headquarters Leonardo Da Vinci, number 1 08191 Rubí (Barcelona) Spain OFFSHORE CABLES Tel +4 9 586 21 78 +4 9 586 21 68 Fax +4 9 586 21 65 sales@topcableoffshoremarine.com http://www.topcableoffshoremarine.com
More informationBS FP600 achieves the maximum 120 minute rating under the BS test conditions, which is required for fire fighting applications.
FIRE RESISTANT CABLES FP600 FIRE RESISTANT CABLES FP600 BS7346-6 FP600 > Prysmian FP600 is a unique enhanced performance fire resistant power cable, designed specifically to meet the more onerous fire
More informationAuthor Owner Issue Authority Name: Gordon MacKenzie Title: Senior Engineer Engineering Design and Standards
1. SCOPE This Specification details requirements for General Wiring cables up to and including 450/750V for use on lighting and general power wiring installations complying with BS 7671 but not forming
More informationUNIKA Universal Cable Cable Specialist
UNIKA Universal Cable Cable Specialist Committed to Quality At ÜNİKA, quality is an intrinsic part of our Operations. Our comprehensive product and System certification not only are mandatory requirements
More informationoutdoor and indoor campus backbone, building backbone (riser) FDDI, Gigabit Ethernet and ATM Easy to install direct burial halogen-free
GUSN Central Loose Tube Cables (Distribution) Universal Indoor/ Outdoor A/I-DQ(ZN)BH Standard Rodent Protection 05-04-8 v0.0 Ordering Information Belden Part Numbers Fibre Description / count 4 6 8 6 4
More informationCIR CRUSH & IMPACT RESISTANT OIL & GAS CABLES
CIR CRUSH & IMPACT RESISTANT OIL & GAS CABLES Gexol CIR Crush and Impact Resistant Without External Armoring Passes the same stringent crush and impact testing required by UL 2225 for Type MC-HL Index
More informationFlexflame. Arctic Grade Cables for Extreme Conditions. Photo: Sakhalin Energy Investement Company Ltd.
Flexflame Arctic Grade Cables for Extreme Conditions Photo: Sakhalin Energy Investement Company Ltd. Linking the future Draka Norsk Kabel is a part of Prysmian Group, a worldwide leader in the cable industry.
More informationDNVGL-CP-0402 Edition February 2016
CLASS PROGRAMME Type approval DNVGL-CP-0402 Edition February 2016 The electronic pdf version of this document, available free of charge from http://www.dnvgl.com, is the officially binding version. FOREWORD
More informationZH Low Smoke 0-Halogen Flameretardant Identification Sleeves
STANDARD TUBE COLOR ZH Low Smoke 0-Halogen Flameretardant Identification Sleeves TECHNICAL DATA SHEET Revision Number. 1 Last Edited 24. juli 2018 The ZH-2X Heat Shrinkable Wire Markers are made of halogen
More informationData sheet OpDAT breakout cable 12x1 OM4 - bend insensitive, class Dca s1 d1 a1
Page 1/9 Illustrations Principle diagram See enlarged drawings at the end of document Product specification connection cable I-V(ZN)HH breakout cable for direct connector termination for indoors and outdoors
More informationTratos Railway Cables
January 2013 Tratos Railway Cables Cables for a moving world www.tratos.eu Introduction Tratos Cavi is a company specialising in the production of power, signalling, control and telecommunications cables
More informationTether and Umbilical Cables for Remotely Operated Vehicles
Tether and Umbilical Cables for Remotely Operated Vehicles 6000 meters down is no place for cable failure TE Connectivity (TE) helps you go deep, whether it s to the ocean floor, the bottom of a mine,
More informationDNVGL-CP-0399 Edition March 2016
CLASS PROGRAMME Type approval DNVGL-CP-0399 Edition March 2016 The electronic pdf version of this document, available free of charge from http://www.dnvgl.com, is the officially binding version. FOREWORD
More informationSchedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK
2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Presley House Presley Way Crownhill Milton Keynes MK8 0ES United Kingdom Contact: Jeremy Hodge Tel: +44 (0) 1908 267300 Fax: +44 (0) 1908
More informationComtran Cable. Hub-LINK Cables for Transit Applications
Comtran Cable Hub-LINK Cables for Transit Applications Overview Hub-LINK rail transit cables are designed to resist the rugged conditions of the underground and at-grade environments, including: Temperature
More informationBS EN : Measurements Of Smoke Density Of Electric Cables. WF Report Number. Date: 17 th November Test Sponsor:
BS EN 61034-2: 2005 Measurements Of Smoke Density Of Electric Cables WF Report Number 177599 Date: 17 th November 2008 Test Sponsor: FTC Fabbrica Trentina Conduttori Srl 0249 Page 2 of 13 Bodycote warringtonfire
More informationMASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 28 ELEC. SAFETY & SECURITY SECTION CONDUCTORS AND CABLES FOR ELECTRONIC SAFETY AND SECURITY
SECTION 280513 - CONDUCTORS AND CABLES FOR ELECTRONIC SAFETY AND SECURITY PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Coaxial cabling. 2. RS-232 cabling. 3. RS-485 cabling. 4. Low-voltage control
More informationFiretuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red
OFC-UT-CST Fire resistant Armoured Indoor/Outdoor steel tape armoured (CST) double LSHF-FR sheathed optical cable with 2 24 fibres. VDE: A/I-DQ(ZN)H(SR)H 3rd party verification of the fire tests by BUREAU
More informationCONTENTS. Introduction Customer Service BS codes of practice BS Fire Performance Cable Selection Guide... 7
CONTENTS Page Introduction... 1 Customer Service... 2 BS codes of practice BS 8519... 5 Fire Performance Cable Selection Guide... 7 FlamBICC Introduction...8 FlamBICC 1...10 FlamBICC 2...12 FlamBICC 3...14
More informationFlexible Power Cable DLO
37-119 Flexible Power Cable DLO 2000 Volts 90 C Diesel Locomotive Cable Limited Smoke (Sizes 2/0 and higher) EP/CPE RHH, RHW-2 Flexible-stranded, tin-coated annealed copper Flame retardant, oil and sunlight
More informationAFUMEX LSX LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS:
PRODUCT DATASHEET & APPLICATIONS GUIDE LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 KEY BENEFITS: BASEC approved for the full size range of BS8436 (1.0mm 2 to 2.5mm 2 ) Additionally tested for
More informationSchedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK
ISO/IEC 17065:2012 to provide product conformity certification Presley Way Crownhill Milton Keynes MK8 0ES Contact: Tracie Hunter Tel: +44 (0)1908 267300 Fax: +44 (0)1908 267255 E-Mail: mail@basec.org.uk
More informationCONNECTION SYSTEMS TRANSIT APPLICATIONS
CNNECTIN SYSTEMS TRANSIT APPLICATINS Ensure electrical and mechanical reliability with the engineered products and solutions of Shawcor s Connection Systems group INTEGRITY IS BEHIND EVERYTHING WE D. By
More informationLow Smoke Zero Halogen
Low Smoke Zero Halogen Cable for Marine Applications 621 Time Saver Avenue Harahan, LA 70123 Call Toll Free: (888) 326-5174 Email: marine@summit.com Marine Division summit.com/marine Power and Control
More informationAFUMEX LSX BASEC APPROVED LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS:
PRODUCT DATASHEET & APPLICATIONS GUIDE BASEC APPROVED LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 KEY BENEFITS: BASEC approved for the full size range of BS8436 (1.0mm 2 to 2.5mm 2 ) Additionally
More informationFIRE RESISTANT CABLES FP300
FIRE RESISTANT CABLES FP300 Fire resistant LSOH power cables for fixed wiring FIRE RESISTANT CABLES FP300 LPCB Ref No: 077e/01 FP300 > Prysmian FP300 is designed for cabling essential safety circuits associated
More informationBS EN :2004. Test On Electric And Optical Fibre Cables Under Fire Conditions. WF Report Number. Date: 14 th November 2008.
BS EN 60332-1-2:2004 Test On Electric And Optical Fibre Cables Under Fire Conditions WF Report Number 177604 Date: 14 th November 2008 Test Sponsor: FTC Fabbrica Trentina Conduttori Srl 0249 Page 2 of
More informationSystem Circuit integrity in the event of fire. Safety cables and systems from a pro. Cabling Solutions
System Circuit integrity in the event of fire and systems from a pro Cabling Solutions Safety cable systems Halogen-free safety cables with reference to VDE H05Z-K, H07Z-K / U / R 22 NHXMH, (N)HXM(St)H
More informationSOLAR CABLES. Electric cables for solar PV installations
SOLAR CABLES Electric cables for solar PV installations TOP CABLE Top Cable is an internationally recognized manufacturer of electric cables, and is highly thought of by professional Engineers & Electricians
More information