Multi-Core Fire Resistant Cable
|
|
- Eric Lewis
- 5 years ago
- Views:
Transcription
1
2 Fire Resistant Cables / Multi-Core Fire Resistant Cable Approved to UL 444, Zeta ZFP series cables have received UL approval for standard applications. Standards Alarm Cable Z UL 444 Approval CMH Rated CM Rated CMR Rated CMX Rated CMG Rated UL Approval E3261 Data Capability ZFP series cables have excellent data/signal transmission characteristics, making it ideal for voice alarm, addressable and networked systems. Key application of ZFP series cables Conventional Fire alarm systems (detection & noti cation circuits) Addressable re alarm systems Voice alarm systems Emergency lighting Other essential service circuits Colour identi cation 2 Core: brown & blue 3 Core: brown, black & grey 4 Core: brown, blue, black & grey Outer Sheath: red or white Features Flame-retardant, low smoke & halogen free Anti re construction to prevent ame propagation Easy to install Superb working exibility 1mm, 1.5mm, 2.5mm & 4mm cable sizes available ble ZFP-215ER
3 Solid Copper Conductor Cores Aluminium Foil Shield Low Smoke Halogen Free Sheath Low Smoke Halogen Free Insulation Tinned or Bare Solid Copper Earth Wire Approval E M TWO CORE ZFP Series THREE CORE ZFP Series FOUR CORE ZFP Series Model No. ZFP-210ER/H-100 ZFP-215ER/H-100 ZFP-225ER/H-100 ZFP-240ER/H-100 ZFP-310ER/H-100 ZFP-315ER/H-100 ZFP-325ER/H-100 ZFP-340ER/H-100 ZFP-410ER/H-100 ZFP-415ER/H-100 ZFP-425ER/H-100 ZFP-440ER/H-100 Nominal cross sectional area (mm 2 ) Conductor construction (Number of strands / Strand diameter) Mean overall diameter (mm) Approx. cable weight (kg/km) conductor resistance at 20 C (ohms/km) Enclosed current rating -DC or single phase AC (Amps) Clipped current rating -DC or single phase AC (Amps) Voltage drop -DC or single phase AC (mv/a/m) Part Number Key /1.13 1/1.38 1/1.78 7/0.85 1/1.13 1/1.38 1/1.78 7/0.85 1/1.13 1/1.38 1/1.78 7/ /H-500 Ref Meaning Other Options ZFP Zeta re proof cable N/A 2 Number of conductors 3 or 4 10 Cable cross section area 1.5, 2.5 or 4.0 E Includes earth conductor N (No earth) R Outer sheath colour W (White) H Harmonized core insulation colours N/A 100 Reel length 100 metres 500m
4 Fire Resistant Cables / Data Communication Fire Resistant Cable (ZFP-UTP/H-305) Zeta Category 5E ( CAT 5 ) 4 pair cables consist of 24 AWG (0.51mm) bare copper conductors insulated with high density polyethylene. The insulated conductors are tightly twisted into pairs and covered with PVC material. The cable provides excellent high-speed transmission, and is certi ed to 155MHz and supports applications such as 155Mb/s ATM and 622Mb/s ATM using parallel transmission technology. It comes supplied on a 305 metre reel. Key Structure Conductor Inner insulation Outer jacket Nominal diameter Voltage rating Operation temperature range Impedance Velocity of propagation Propagation delay skew 24 AWG x 4 pairs solid copper wire PE Diameter 0.95mm LSZH matterial, thickness 0.8mm 5.50mm 300V -20 C to +75 C 100 +/- 15 Ohms/km 69% Nominal 45ns/100m NEXT PSNEXT ELFEXT PSELFEXT Near End Crosstalk is interference between two pairs of a cable measured at the same end of the cable as the transmitter Power Sum Near End Cross Talk is the algebraic sum of near end crosstalk (NEXT) of three wire pairs as they affect the fourth pair in a four-pair cable The Equal-Level Far-End Crosstalk (ELFEXT) test measures Far-End Crosstalk (FEXT). FEXT is very similar to NEXT, but happens at the receiver side of the connection Power Sum ELFEXT is the sum of FEXT values from 3 wire pairs as they affect the other wire pair Performance Frequency (MHz) Attenuation (db/100m) NEXT (db) PSNEXT (db) ELFEXT (db) PSELFEXT (db) Return Loss(dB)
5
6
IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission
ADDISON Flame Retardant CAT5e Data Cables FTX-CAT5e U/UTP4P24 FTX-CAT5e f/utp4p24 FTX-CAT5e sf/utp4p24 LSZH Outer Aluminium/Polyester Tape Solid Copper Conductor PE Insulation Tinned Copper Drain Wire
More informationCAT5E DIRECT BURIAL (FLOODED CORE) 24AWG, UTP, 4 PAIR, SOLID 1000 PULL BOX /CMXF
POST CAT5E DIRECT BURIAL (FLOODED CORE) 24AWG, UTP, 4 PAIR, SOLID 1000 PULL BOX PART NUMBER: 059-485/CMXF 1 APPROVALS: MARKETING DATE: THE INFORMATION CONTAINED IN THIS DOCUMENT IS PROPRIETARY TO VERTICAL
More informationNote: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design.
ADDISON Flame Retardant RG59 B/U Coaxial cables Plain copper wire braid PE Solid Bare Copper PVC Outer Sheath APPLICATION The cables are designed for CCTV, security, smoke detection and evacuation monitoring
More informationCaledonian Flame Retardant Coaxial Cables
Caledonian Flame Retardant Coaxial Cables www.caledonian-cables.co.uk www.addison-cables.com Flame Retardant RG59 Coaxial cables LSZH Outer Sheath Tinned Copper Braid Aluminium+polyester/Aluminium Tape
More informationCATEGORY 6A FTP RJ45 SOLUTION
CATEGORY 6A FTP RJ45 SOLUTION Clipsal titanium Patch Cord Clipsal titanium LSZH Patch Cord Clipsal titanium Keystone Jacks Clipsal titanium Modular Jacks Clipsal titanium Patch Panels Clipsal titanium
More informationCatalogue Telecommunication Cables INTRODUCCIÓN
Catalogue Telecommunication Cables INTRODUCCIÓN Conductores Tecnológicos S.A. www.contecsa.es Index of Cables Page Introduction 3 EAP / EAP-R 4 EAPSP / EAPSP-R 5 ISP / ICP 6 Conductores Tecnológicos S.A.
More informationCompact Module. Category 6A FTP Cabling System 1.1
Updated 24/09/12 Compact Module Cat 6A performance Suitable for 10-Gigabit Ethernet Ultra-slimline design Euro style module Interchangeable with other Euro Modules and blanks Individually QA tested Easy
More informationFIRE RESISTANT CABLES FP200 GOLD
FIRE RESISTANT CABLES FP200 GOLD FIRE RESISTANT CABLES FP200 GOLD BS7629-1 FP200 GOLD Clause 26.2 > The original highly durable and dressable, easy to terminate and install fire resistant cable. Approved
More informationTelecommunication Cables
Telecommunication Cables Telecommunication Cables Introduction 3 EAP / EAP-R 4 EAPSP / EAPSP-R 5 ISP / ICP 6 Page ELECWIRES 2 www.elecwires.es INTRODUCCIÓN Telecommunication Cables Telephone cables suitable
More informationCaledonian Fire resistant Coaxial Cables
Caledonian Fire resistant Coaxial Cables www.caledonian-cables.net www.addison-cables.com Fire resistant rg59 b/u Coaxial Cables RG59 B/U FR LSZH Sheath Fire Resistant Tape Copper Clad Steel/Bare Copper
More informationPRODUCT CATALOGUE Norröna
PRODUCT CATALOGUE Norröna WWW.SCANKAB.COM Table of contents MARINE AND OFFSHORE CABLES 1 TOXFREE XZ1-K (AS) - 0.6/1 kv 1 TOXFREE MARINE XO2TCuZ1-K (AS) - 150/250 V 5 4x2xAWG 24/1 CAT6 S/FTP LSZH-SHF1 -
More information600/1000V XLPE Insulated, LSZH Sheathed, Double steel tape Armoured Power Cables (3 Cores)
Caledonian Flame Retardant Power & Control Cables www.caledonian-s.co.uk www.addison-s.com 600/1000V XLPE Insulated, LSZH Sheathed, Double steel tape Armoured Power Cables (3 Cores) FTX400 1RZ1MZ1-R (CU/XLPE/LSZH/DSTA/LSZH
More information600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (Multicore)
600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (Multicore) FGD400 1RV-R (CU/XLPE/PVC 600/1000V Class ) FGD400 1RVMV-R (CU/XLPE/PVC/SWA/PVC 600/1000V Class ) PVC Outer Sheath Plain Annealed
More informationFIRE RESISTANT CABLES FP PLUS. New Generation. Now with enhanced Insudite TM insulation
FIRE RESISTANT CABLES FP PLUS New Generation Now with enhanced Insudite TM insulation ENHANCED FIRE RESISTANT CABLES FP PLUS BS7629-1:2008 FP PLUS > Certificate No 077g/02 The new generation of FP PLUS
More information600/1000V SR Insulated Flexibles Control Cables (2-4 Cores & Multicores)
600/1000V SR Insulated Flexibles Control Cables (2-4 Cores & Multicores) FFX400 1SZ1-R(PH60)(CU/SR/LSZH 600/1000V Class 2) FFX400 1SZ1-F(PH60)(CU/SR/LSZH 600/1000V Class 5) Silicone Rubber Insulation Plain
More informationCore identification code. J-YY...BD Indoor Cable. J-YY...BD Indoor Cable. VDE 0815 Mutual capacitance. J-YY...BD Indoor Cable. Cu conductor 0.
Indoor cables J-YY...BD Indoor J-Y(ST)Y..LG Indoor Comparable products UNITRONIC J-2Y(ST)Y...ST III BD see page 271 Indoor telephone cables transmit analogue or digital signals In news and communication
More informationC6 Premium. C6 Premium Copper Systems from Infinique is premium performing Class E / Category 6 Data Communication
Stable and Reliable Data Communication Solutions from Infinique Infinique provides high quality end-to-end solutions for communication infrastructure that bring great value to its customers. We have achieved
More informationFlame Retardant Overall Screened Instrumentation Cables (multicore)
Flame Retardant Overall Screened Instrumentation Cables (multicore) RE-2X(St)H RE-2X(St)HSWAH LSZH Outer Sheath Tinned Copper Drain Wire LSZH Inner Sheath XLPE Insulation Plain Annealed Copper Aluminium/polyester
More informationHigh Performance LSZH Fire Resistant Cable
High Performance LSZH Fire Resistant Cable www.cavicel.com 104/2 FIRECEL SR 114H is the long and well established CAVICEL fire resistant cable in the market, since many years. These cables are third party
More informationMosaic TM LCS2 Cat. 6A STP RJ 45 socket
870 LIMOGES Cedex Telephone: + 33 0 5 55 06 87 87 - Fax: + 33 0 5 55 06 88 88 Mosaic TM LCS2 socket Page 765 73 794 76 1. General characteristics....1 2. Presentation...1 3. Installation...1 4. Technical
More informationFIRE RESISTANT CABLES FP200 GOLD
FIRE RESISTANT CABLES FP200 GOLD FIRE RESISTANT CABLES FP200 GOLD BS7629-1:2008 FP200 GOLD FIRE RESISTANT CABLES Key Applications Fire detection and fire alarm systems for buildings Voice alarm systems
More informationProduct Specification CAT 6 UNSHIELDED PATCH CORDS
Product 108-93017 Specification 23/Nov/06 Rev. A CAT 6 UNSHIELDED PATCH CORDS 1. SCOPE 1.1 Content This specification describes performance and material requirements and tests procedures for NETCONNECT
More informationFIRE RESISTANT CABLES
Conducting Value The Last Cable Standing FIRE RESISTANT CABLES 100/7b ISO 9001:2008 Certificate No. CS1-249 MANAGEMENT SYSTEMS Assessed to ISO 9001:2008 Cert/LPCB ref. 217 GOST ISO 9001-2011 (ISO 9001:2008)
More informationBS /1000V XLPE Insulation LSZH Sheath Cables
BS 8573 600/1000V XLPE Insulation LSZH Sheath Cables Caledonian www.addison-cables.com Company Profile Caledonian & Addison, branded under Caledoniea & Addimax, established in 1978, offers one of the most
More informationS Low loss coax cables with foamed PE
S Low loss coax cables with foamed PE Cable design Electrical cable data Impedance () 50 Capacitance 82 pf/m Velocity of signal propagation 82 % of the speed of light Epsilon r 1.5 Signal delay 4.1ns/m
More informationFIRE PERFORMANCE CABLE
FIRE PERFORMANCE CABLE Manufactured to BS 7629-1 Table 1 Plain Annealed Copper Conductors / Silicone Rubber Insulated / Double Layer of Aluminium/ Polyester Laminated Tapes / Circuit Protective Conductor
More informationAFUMEX LSX LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS:
PRODUCT DATASHEET & APPLICATIONS GUIDE LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 KEY BENEFITS: BASEC approved for the full size range of BS8436 (1.0mm 2 to 2.5mm 2 ) Additionally tested for
More informationAFUMEX LSX BASEC APPROVED LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS:
PRODUCT DATASHEET & APPLICATIONS GUIDE BASEC APPROVED LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 KEY BENEFITS: BASEC approved for the full size range of BS8436 (1.0mm 2 to 2.5mm 2 ) Additionally
More informationCABLES FOR ALARM AND SAFETY SYSTEMS
CABLES FOR ALARM AND SAFETY SYSTEMS 2 IT S ALL ABOUT RELIABILITY. It is always important to choose high quality cables, especially when it comes to alarms and safety systems. Even small and seemingly insignificant
More informationSHIELD TYPE MULTICONDUCTOR MULTIPAIR
CABLE FINDER GUIDE CONDUCTOR SIZE 18 AWG METRIC 0,97mm 2 SHIELD TYPE MULTICONDUCTOR MULTIPAIR Materials Ratings No. of Alpha Page No. of Alpha Page Cable Type Insulation Jacket Temp. Voltage Conductors
More informationENHANCED FIRE PERFORMANCE CABLE
FIRE PERFORMANCE CABLE Manufactured to BS 7629-1 Table 1 Plain Annealed Copper Conductors / Silicone Rubber Insulated / Glass Fibre Tape / Tinned Copper Circuit Protective Conductor / Double Layer of Copper/Polyester
More informationCopper LAN cable. This specification describes the general requirements for AMP NETCONNECT* copper LAN cable.
Product Specification 108-93018 25/Aug/2011 Rev H Copper LAN cable 1. SCOPE 1.1. Content This specification describes the general requirements for AMP NETCONNECT* copper LAN cable. 2. APPLICABLE DOCUMENTS
More informationBS EN :2004. Test On Electric And Optical Fibre Cables Under Fire Conditions. WF Report Number. Date: 14 th November 2008.
BS EN 60332-1-2:2004 Test On Electric And Optical Fibre Cables Under Fire Conditions WF Report Number 177603 Date: 14 th November 2008 Test Sponsor: FTC Fabbrica Trentina Conduttori Srl 0249 Page 2 of
More informationHome Theater Cables. Your complete solution for high-end audio transmission, stereo, professional audio systems and home theater systems.
Home Theater Cables Your complete solution for high-end audio transmission, stereo, professional audio systems and home theater systems. Home Theater Sound Jacketed Cables Shielded: Twisted Bare Copper
More informationComtran Cable. Hub-LINK Cables for Transit Applications
Comtran Cable Hub-LINK Cables for Transit Applications Overview Hub-LINK rail transit cables are designed to resist the rugged conditions of the underground and at-grade environments, including: Temperature
More informationArteor TM LCS2 Cat. 6A STP RJ 45 socket
87045 LIMOGES Cedex Telephone: + 33 0 5 55 06 87 87 - Fax: + 33 0 5 55 06 88 88 Arteor TM Page 5 723 06 5 723 50 1. General characteristics....1 2. Presentation...1 3. Real life scenarios...1 4. Technical
More informationGUARDIANTM QUALITY APPROVED CABLES. Cables Limited MADE IN IRELAND SINCE 1934 IDH CABLES LIMITED MECHANICALLY PROTECTED CABLES
Cables Limited MADE IN IRELAND SINCE 1934 QUALITY APPROVED CABLES IDH CABLES LIMITED GUARDIANTM MECHANICALLY PROTECTED CABLES The original BS-8436, IS-273 multifunctional, easy to install, connect-and-protect
More informationIEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission
Flame Retardant RS485 Databus Cables Copper Wire Braid(optional) Individual AL/Polyester Tape(optional) Foam PE/Foam skin PE. Stranded Tinned Copper AL/Polyester Tape With Tinned Copper Drain Wire LSZH
More informationThe Next Generation of Data Communicatons Solutions
19 Systems Enclosures The Next Generation of Data Communicatons Solutions In 2003, Clipsal Datacomms embarked on a research and development program with the intention of introducing a range of products
More informationPower Cables. Introduction 3 RV 4 RVMV 5 RVSV 6 RVFV 7. ELECWIRES 2 Page
Power Cables Power Cables Page Introduction 3 RV 4 RVMV 5 RVSV 6 RVFV 7 ELECWIRES 2 www.elecwires.es INTRODUCTION Power Cables Power cables for electrical installations, domestic & industrial, specifically
More informationLSOH Flexible Cables
LSOH Flexible Cables Low Voltage (300/500 V) 3182B, 3183B, 3184B Piresafe TM Flex Cable Approvals Key Applications > Supply leads for medium duty domestic and office appliances, lighting fittings and portable
More informationFiretuf Cables ZERO HALOGEN, LOW SMOKE (0HLS ) CABLE
Firetuf Cables ZERO HALOGEN, LOW SMOKE (0HLS ) CABLE Draka, the world s mo When it comes to specifying fire performance cables, zero halogen building wires and power cables, you have to choose products
More informationFiretuf Cables ZERO HALOGEN, LOW SMOKE (0HLS ) CABLE
Firetuf Cables ZERO HALOGEN, LOW SMOKE (0HLS ) CABLE Draka, the world s most trusted cable brand When it comes to specifying fire performance cables, zero halogen building wires and power cables, you have
More informationFIRE RESISTANT CABLES FP300
FIRE RESISTANT CABLES FP300 Fire resistant LSOH power cables for fixed wiring FIRE RESISTANT CABLES FP300 LPCB Ref No: 077e/01 FP300 > Prysmian FP300 is designed for cabling essential safety circuits associated
More informationIEC UNE DESIGN. 1. Conductor. 2. Insulation. Cross-linked polyethylene (XLPE) 3. Outer sheath. Flexible PVC, black colour.
67 POWERFLEX RV-K POWERFLEX RV-K Industrial flexible cable for power transmission. 1 IEC 60502-1 - UNE 21123-2 DESIGN 1. Conductor 2 Electrolytic copper, class 5 (flexible), based on EN 60228 and IEC 60228.
More informationQualification Test Report. AMP-TWIST Series Jacks for Class EA systems
Qualification Test Report 501-93032 14/April/2011 Rev A AMP-TWIST Series Jacks for Class EA systems 1. INTRODUCTION 1.1 Purpose Qualification testing on AMP-TWIST* Series Jacks for Class E A Systems, to
More informationAMP NETCONNECT Category 5E SL Shielded Cabling System. 1. General Description
Category 5E SL Shielded Cabling System Table of Content: 1. General System 7.1. DIN Style Faceplates & Outlets 2. System Cables 7.2. 45x45 MOSAIC Style Faceplates & Outlets 3. Category 5E Shielded SL (SlimLine)
More informationTYPE APPROVAL CERTIFICATE
TYPE APPROVAL CERTIFICATE Certificate No: TAE00000GG Revision No: 2 This is to certify: That the Data transmission cables and systems with type designation(s) MGD Cat 3, MGD Cat 5, Cat 5e, MGD cat 6, Cat
More informationIntroduction.
Introduction The safety of occupants and users of public, commercial and industrial premises is of paramount importance. One important safety feature is the appropriate use of fire performance cables for
More informationSPECIAL ELECTRICAL AND OPTICAL CABLES
SPECIAL ELECTRICAL AND OPTICAL CABLES INTRODUCTION The new high-speed trains and the sensible increase of the traffic, with congested lines, is the result of the latest development of the rail sector.
More informationINTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 61156-6 First edition 2002-03 Multicore and symmetrical pair/quad cables for digital communications Part 6: Symmetrical pair/quad cables with transmission characteristics up
More informationPAIRED UNJACKETED. Insulation Nominal Anixter. Paired Conductors Thickness O.D. Number AWG Strand No. IN IN
PVC Stranded and Solid Conductors Listed as Misc. Wire PAIRED UNJACKETED Burglar alarm systems wiring; to sensors, control. BURGLAR ALARM 1. CONDUCTOR: Stranded copper conductors (1/c tinned + 1/c bare)
More informationSTANDARDS INSTALLATION. Certificate No 077m
Certificate No 077m > Prysmian FP600 is a unique enhanced performance fire resistant power cable, designed specifically to meet the more onerous fire survival requirements now requested by regulators and
More informationTitle: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards
Change History Date Description of Change Pages / Sections Modified Change Approver Initials 8/1/17 Updated section on Manufacturers 3 1. 6/15/16 Updated division section from 16120 to 26 05 00, - mgl44
More informationCONTENTS. Introduction Customer Service BS codes of practice BS Fire Performance Cable Selection Guide... 7
CONTENTS Page Introduction... 1 Customer Service... 2 BS codes of practice BS 8519... 5 Fire Performance Cable Selection Guide... 7 FlamBICC Introduction...8 FlamBICC 1...10 FlamBICC 2...12 FlamBICC 3...14
More informationProduct Guide. Fire Alarm Cables. Initiating Device, SLC Lines, and NAC Cables.
Fire Alarm Cables Initiating Device, SLC Lines, and NAC Cables Product Guide STANDARDS Fire Alarm Systems A fire alarm system is number of devices working together to detect and warn people through visual
More informationBS FP600 achieves the maximum 120 minute rating under the BS test conditions, which is required for fire fighting applications.
FIRE RESISTANT CABLES FP600 FIRE RESISTANT CABLES FP600 BS7346-6 FP600 > Prysmian FP600 is a unique enhanced performance fire resistant power cable, designed specifically to meet the more onerous fire
More informationCOMMERCIAL PROTOCOLS AND AEROSPACE CABLING: FINDING THE RIGHT BALANCE
COMMERCIAL PROTOCOLS AND AEROSPACE CABLING: FINDING THE RIGHT BALANCE Robert Moore, Principal Engineer High Speed Specialist AEROSPACE, DEFENSE & MARINE /// WHITE PAPER - COMMERCIAL PROTOCOLS AND AEROSPACE
More informationINTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 61156-4 Edition 3.0 2009-05 Multicore and symmetrical pair/quad cables for digital communications Part 4: Riser cables Sectional specification INTERNATIONAL ELECTROTECHNICAL
More informationFlame Retardant EP/CPE POWER, CONTROL & INSTRUMENTATION CABLES
Flame Retardant EP/CPE POWER, CONTROL & INSTRUMENTATION CABLES 37-754 FLAME RETARDANT EP/CPE TYPE TC OR TC-ER POWER CABLE Two Five Conductor + Ground (Two, Three & Four Conductor) 600 V Rated 90 C Conductor*
More informationCatalogue Power Cables
Catalogue Power Cables Conductores Tecnológicos S.A. www.contecsa.es Index of Cables Page Introduction 13 RV 14 RVMV 15 RVSV 16 RVFV 17 Conductores Tecnológicos S.A. 2 www.contecsa.es INTRODUCTION Power
More informationPHOTOVOLTAIC CABLES. Photovoltaic Cable 2000V/1500V Photovoltaic Cable 2000V/1000V
PHOTOVOLTAIC CABLES PHOTOVOLTAIC CABLES INDEX n AmerSol Dual-Certified (UL / ETL) Photovoltaic Cable 2000V/1500V....................... 2-3 n AmerSol Dual-Certified (UL / ETL) Photovoltaic Cable 2000V/1000V.......................
More informationCaledonian fire Resistant signal & Data cables
fire Resistant signal & Data cables www.addison-tech.com fire Resistant Rs485 Databus cables Copper Wire Braid(optional) Individual AL/Polyester Tape(optional) Mica Glass Tape+PE/PE+Silicone Rubber Insulation
More informationCORFLEX. TYPE MC-HL & MV-105 or MC-HL OIL & GAS CABLES
CORFLEX TYPE MC-HL & MV-105 or MC-HL OIL & GAS CABLES INDEX Instrumentation Cables - Pairs and Triads (0V*)... 2 - The Original MC-HL Technology In 1958 Canada Wire and Cable, which s now part of Nexans,
More informationTotal Fire Solutions. Includes BS 8519 and the updated BS :
Total Fire Solutions Includes BS 8519 and the updated BS 5266-1:2011 www.aeicables.co.uk Introduction: Total Fire Solutions Power and control cable systems for life safety and fire-fighting applications
More informationFire Resistant Cables
Fire Resistant Cables Ducab (Abu Dhabi) Factory P.O. Box 9171, Abu Dhabi, UAE Tel: (971-2) 502 7777 Fax: (971-2) 502 7888 email: ducab@ducab.com Ducab Connect P.O. Box 11529, Dubai, United Arab Emirates
More informationTable of Contents. TELE-FONIKA KABLE SA (DMCC Branch). 4 TELE-FONIKA Kable Group 6 FLAME-X 950 SERIES 1 11 FLAME-X 950 SERIES 2
FLAME-X 950 TELE-FONIKA KABLE SA (DMCC Branch). Table of Contents is the Regional Middle East Sales Office of Tele-Fonika Kable S.A. from Poland, 4-th largest manufacturer of electric cables and wires
More informationArteor TM LCS2 Cat. 6A UTP RJ 45 socket
87045 LIMOGES Cedex Telephone: + 33 0 5 55 06 87 87 - Fax: + 33 0 5 55 06 88 88 Arteor TM Page 5 723 49 5 723 57 1. General characteristics....1 2. Presentation...1 3. Real life scenarios...1 4. Technical
More informationAll Prysmian FP400 cables are manufactured under an ISO 9001 Quality System certified by BASEC and LPCB.
Certificate No 077b Certificate No 517b > Prysmian FP400 is the original fire resistant armoured cable providing an easy to install and terminate, robust fire resistant wiring system. In addition to maintaining
More informationCompany Profile. We are dedicated to providing our customers competitive price and excellent service.
1 Company Profile Hangzhou Kingtone Electronics Co., Limited is a Chinese wire & cable manufacturer specializing in manufacturing Coaxial Cable, Lan Cable, Alarm/Security Cable, Power Cable, Speaker Cable
More informationfire resistant cables
Building Technology fire resistant cables Special electrical and optical cables www.tecnikabel.com Special electrical and optical cables 2 INTRODUCTION Structured cabling solutions. Tecnikabel can provide
More informationMASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 28 ELEC. SAFETY & SECURITY SECTION CONDUCTORS AND CABLES FOR ELECTRONIC SAFETY AND SECURITY
SECTION 280513 - CONDUCTORS AND CABLES FOR ELECTRONIC SAFETY AND SECURITY PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Coaxial cabling. 2. RS-232 cabling. 3. RS-485 cabling. 4. Low-voltage control
More informationCategory 5 Premise Wire
Category 5 Premise Wire engineered with you in mind Features Copper and Fiber Optic Cable Manufacturer U.S. Manufacturer State-of-the-Art Quality Labs ISO9001 Accredited Standard and Extended Warranties
More informationSAS Security and Alarm Safety Cables
CABLES Security and Alarm Safety Cables Security and Alarm Safety Cables LOW SMOKE ZERO HALOGEN The right range of cables for modern building installations e-catalogue 203/4 Flexible solutions for commercial,
More informationCORFLEX TYPE MC-HL POWER, CONTROL & INSTRUMENTATION CABLES
CORFLEX TYPE MC-HL POWER, CONTROL & INSTRUMENTATION CABLES CORFLEX TYPE MC-HL POWER, CONTROL & INSTRUMENTATION CABLES INDEX Corflex MC-HL Instrumentation - Pairs and Triads (0V*)... 1 - CORFLEX Cables
More informationFire alarm cables. for highest safety requirements TRADITION INNOVATION PASSION
Fire alarm cables for highest safety requirements TRADITION INNOVATION PASSION Datwyler Datwyler Cabling Solutions is an internationally operating company with its headquarters in Switzerland and affiliates
More informationAuthor Owner Issue Authority Name: Gordon MacKenzie Title: Senior Engineer Engineering Design and Standards
1. SCOPE This Specification details requirements for General Wiring cables up to and including 450/750V for use on lighting and general power wiring installations complying with BS 7671 but not forming
More informationFIRE RESISTANT CABLES FP400
FIRE RESISTANT CABLES FP400 FIRE RESISTANT CABLES FP400 BS7846-F2 CABLE CHARACTERISTICS FP400 APPROVALS INSTALLATION Certificate No 077b Certificate No 517b > Prysmian FP400 is the original fire resistant
More informationCat 6 Unshielded Patch cords
Product Specification 108-93017 13/Oct/2009 Rev D Cat 6 Unshielded s 1. SCOPE 1.1 Content This specification describes performance and material requirements and tests procedures for AMP NETCONNECT* Cat
More informationMultipurpose Cables (indoor/outdoor), Multipurpose central tube cable (maxibundle) with glass yarn armouring A-DQ(BN)H 4-24
Features and Benefits Laminated swelling glass yarns Improved rodent resistance and longitudinal water protection UV and microbe resistant Can be directly buried or installed in ducts Metal-free cable
More informationFlexible Power Cable DLO
37-119 Flexible Power Cable DLO 2000 Volts 90 C Diesel Locomotive Cable Limited Smoke (Sizes 2/0 and higher) EP/CPE RHH, RHW-2 Flexible-stranded, tin-coated annealed copper Flame retardant, oil and sunlight
More informationBS EN : Measurements Of Smoke Density Of Electric Cables. WF Report Number. Date: 17 th November Test Sponsor:
BS EN 61034-2: 2005 Measurements Of Smoke Density Of Electric Cables WF Report Number 177599 Date: 17 th November 2008 Test Sponsor: FTC Fabbrica Trentina Conduttori Srl 0249 Page 2 of 13 Bodycote warringtonfire
More informationData sheet OpDAT breakout cable 12x1 OM4 - bend insensitive, class Dca s1 d1 a1
Page 1/9 Illustrations Principle diagram See enlarged drawings at the end of document Product specification connection cable I-V(ZN)HH breakout cable for direct connector termination for indoors and outdoors
More informationCable technology for highest safety requirements
Cable technology for highest safety requirements Daetwyler We are a provider of high-grade quality system solutions and services in the areas of structured data cabling, telecom carriers, safety cabling,
More information/Oct/2014 Rev B
Product Specification 108-93042 07/Oct/2014 Rev B Class EA shielded solid Patch cords 1. SCOPE 1.1 Content This specification describes performance and material requirements and tests procedures for TE
More informationDouble insulated, electron-beam cross-linked, halogen free photovoltaic wire sunlight resistant. Single conductor, flame retardant insulation.
Technical Data Sheet BETAflam Solar 125 flex UL 4703 Description Double insulated, electron-beam cross-linked, halogen free photovoltaic wire sunlight resistant. Single conductor, flame retardant insulation.
More informationPhotovoltaic Cables EN H1Z2Z2-K
Photovoltaic Cables EN 50618 H1Z2Z2-K COMPANY PROFILE Caledonian, established in 1978, offers one of the most complete lines of fiber and copper cabling system solutions with over hundreds of different
More informationSecurity & Control Cables
Security & Control Cables Our multi-conductor cables are manufactured in a wide variety of gauge sizes, shielding configurations and jacketing materials including plenum, riser and general purpose. Applications
More informationIndustrial Fiber Optic Cables, LSZH Corrugated Armored Cable, Fibers
Features and Benefits Corrugated armor Mechanical protection Low-smoke/zero-halogen (LSZH ) sheath Key life-safety benefit Meets cyclic impact and chemical resistance test Superior performance Tray-rated
More informationINTRODUCTION. Our diverse range of world-class Specialty Insulated Wires and Cablesinclude: LV Cables -
MARINE CABLES Your Power Partner on the Seas INTRODUCTION We, a member of the Al-Bahja Group of Companies, are an ISO:900:2008 BASEC, UK certified integrated quality producer of LV and MV Cables, Wires&
More informationBS EN :2004. Test On Electric And Optical Fibre Cables Under Fire Conditions. WF Report Number. Date: 14 th November 2008.
BS EN 60332-1-2:2004 Test On Electric And Optical Fibre Cables Under Fire Conditions WF Report Number 177604 Date: 14 th November 2008 Test Sponsor: FTC Fabbrica Trentina Conduttori Srl 0249 Page 2 of
More informationSpecial Provision No. 683S28 December 2017
FIBRE OPTIC COMMUNICATION CABLES, AERIAL ON MESSENGER CABLE - Item No. FIBRE OPTIC COMMUNICATION CABLES, AERIAL ON MESSENGER CABLE (TEMPORARY) - Item No. Special Provision No. 683S28 December 2017 1. SCOPE
More informationBS 6387: 1994 Specification for performance requirements for cables required to maintain circuit integrity under fire conditions.
BS 6387: 1994 Specification for performance requirements for cables required to maintain circuit integrity under fire conditions WF Report Number: 147709 Test Sponsor: FTC - Fabbrica Trentina Conduttori
More informationPOINT OBSTRUCTION CONTROLLER POC TOUCHSCREEN CONTROLLERS
POINT OBSTRUCTION CONTROLLER Compliances: FAA Advisory Circular 70/7460-1L ICAO Annex 14, Volume I, Chapter 6 The controller provides the control and monitoring functions for an LED red obstruction lighting
More information/Oct/2014 Rev E
Product Specification 108-93017 14/Oct/2014 Rev E Cat 6 Unshielded Patch Cords 1. SCOPE 1.1 Content This specification describes performance and material requirements and tests procedures for TE Connectivity
More informationIDENTIFYING TRAY CABLES FOR YOUR NEXT INSTALLATION A WHITE PAPER
IDENTIFYING TRAY CABLES FOR YOUR NEXT INSTALLATION A WHITE PAPER Published 3/23/2012 T hough rapidly increasing in popularity, tray cables are still a point of confusion for many. While the term tray cable
More informationSECTION CONDUCTORS AND CABLES FOR ELECTRONIC SAFETY AND SECURITY
SECTION 280513 CONDUCTORS AND CABLES FOR ELECTRONIC SAFETY AND SECURITY PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions
More informationCatalogue. Instrumentation & Control Cables
Catalogue Instrumentation & Control Cables Conductores Tecnológicos S.A. www.contecsa.es Index of Cables Page Introduction 3 Instrumentation VOV 4 VHOV 5 VOVMV 6 VHOVMV 7 Control RV 8 RZ1C3Z1 9 Conductores
More informationData sheet OpDAT universal cable 1x24 OM4 - bend insensitive
Illustrations Principle diagram Page 1/7 Product specification installation cable U-DQ(ZN)BH universal fiber optic cable for indoors/outdoors with central or stranded loose tube bend insensitive fiber
More informationPANDUIT 4-PAIR & MULTIPAIR COPPER DATA CABLE PLENUM RATED
ENVIRONMENTAL PRODUCT DECLARATION PANDUIT 4-PAIR & MULTIPAIR COPPER DATA CABLE PLENUM RATED At Panduit, we re serious about sustainability. Everyone s talking about sustainability these days. Companies
More information