1 CATEGORY 6A FTP RJ45 SOLUTION Clipsal titanium Patch Cord Clipsal titanium LSZH Patch Cord Clipsal titanium Keystone Jacks Clipsal titanium Modular Jacks Clipsal titanium Patch Panels Clipsal titanium Fully Featured Patch Panel Clipsal titanium Cable Clipsal titanium LSZH Cable Clipsal titanium Cable Management Panel Deep Clipsal Side Rings MUTOs

2 CLIPSAL DATACOMMS CATEGORY 6A FTP RJ45 SOLUTION INTRODUCTION Clipsal titanium Category 6A FTP RJ45 Solution The Clipsal Titanium Category 6A FTP patched solution provides a shielded product, which prevents AXT (Alien Cross Talk). This solution includes FTP cable, patch panels, patch leads, modular jacks, faceplates and cable management. This system is designed to support 10G Base T applications, and offers a great solution for an installation requiring high-speed and high bandwidth. The Clipsal Lifetime warranty is available upon application. 80

3 CLIPSAL DATACOMMS CATEGORY 6A FTP RJ45 SOLUTION PATCH CORD Clipsal titanium Category 6A FTP Patch Cord The Clipsal titanium Series Category 6A FTP Patch Cord is a superior product delivering the best network performance when used in conjucntion with this series of products. The patch cord is constructed of high grade cable and quality RJ45 plugs, and is designed to operate up to 500MHz. This enables it to operate successfully in a Category 6A environment. RJ6AF8A10PL,BU MECHANICAL CHARACTERISICS Cable Gauge (AWG) 26 AWG Pair Count 4 Pair individually colour coded with filler and PVC jacket Sequence Wiring sequence T568 A Durability 750 mating cycles RJ45 Plug FCC Part 68 Subpart Contact Material Phosphor bronze with 50 micro-inches gold over 100 micro-inches nickel Fully compliant to AS/NZS 3080:2003, ISO/IEC Edition and ANSI/TIA/EIA-568-C Series Channel and Link Standards. PE insulation on conductors. PVC outer jacket material. Available in multiple lengths. Backward compatible with Category 5e and 6 products. Designed to mitigate ANEXT. Snag-free design. Strain relief boot. Current Rating Insulation Contact Resistance 2.0 A maximum 500MΩ minimum 20MΩ maximum Performs to Category 6A international standards. Comes in various lengths to assist with better cable management. Backward compatible with Category 5e and 6. LINE DRAWING RJ6AF8A10PL,BU Patch Cord Category 6A FTP 568A 1.0m RJ6AF8A20PL,BU Patch Cord Category 6A FTP 568A 2.0m RJ6AF8A30PL,BU Patch Cord Category 6A FTP 568A 3.0m RJ6AF8A50PL,BU Patch Cord Category 6A FTP 568A 5.0m 81

4 CLIPSAL DATACOMMS CATEGORY 6A FTP RJ45 SOLUTION PATCH CORD Clipsal titanium Category 6A FTP Patch Cord Low Smoke Zero Halogen The Clipsal titanium Series Category 6A FTP Patch Cord is a superior product delivering the best network performance when used in conjunction with other Clipsal titanium Category 6A products. The patch cord is constructed of high grade cable and quality RJ45 plugs, and is designed to operate up to 500MHz. This enables it to operate successfully in a Category 6A FTP environment. Clipsal Datacomms has released a range of PVC free, Low Smoke Zero Halogen (LSZH) Category 6A FTP LAN cable and patch cords. The LSZH sheath is composed of thermoplastic and thermoset compounds that emit limited smoke and zero halogens (poisonous gases) when exposed to high sources of heat or fire and are PVC free. Clipsal titanium 4 Pair LSZH Category 6A FTP LAN Cable and patch cords are superior products delivering excellent network performance and a "greener" peace of mind. More LSZH and RoHS products are being used as networks move toward a "greener" workplace and environment. MECHANICAL CHARACTERISICS Cable Gauge 26 AWG Pair Count 4 Pair individually colour coded with filler and LSZH jacket Sequence Wiring sequence T568 A Durability 750 mating cycles RJ45 Plug FCC Part68 Subpart F Plug Boot LSZH Contact Material Phosphor bronze with 50 micro-inches gold over 100 micro-inches nickel RJ6A8A10LPL, BU Cable sheath complies with IEC C (HF3). Fully compliant to AS/NZS 3080:2003, ISO/IEC Edition and ANSI/TIA/EIA-568-C Series Channel and Link Standards. UL CMR fire rated jacketing. PE insulation on conductors. Available in multiple lengths. Designed to mitigate ANEXT. Performs to Category 6A international standards. Comes in various lengths to assist with better cable management. Backward compatible with Category 5 and 6 products. Complies to LSZH requirements. Current Rating Insulation Contact Resistance 2.0 A maximum 500MΩ minimum 20MΩ maximum LINE DRAWING 82 RJ6AF8A10LPL,BU Patch Cord Category 6A FTP LSZH 568A 1.0m RJ6AF8A20LPL,BU Patch Cord Category 6A FTP LSZH 568A 2.0m RJ6AF8A30LPL,BU Patch Cord Category 6A FTP LSZH 568A 3.0m RJ6AF8A50LPL,BU Patch Cord Category 6A FTP LSZH 568A 5.0m

5 CLIPSAL DATACOMMS CATEGORY 6A FTP RJ45 SOLUTION JACKS Clipsal titanium Category 6A FTP Jack Modular - Suits Clipsal Wall Plates C A B Fully compliant to AS/NZS 3080:2003, ISO/IEC , ANSI/TIA/EIA-568-C Series and ANSI/TIA/EIA- 568-B.2-10 (draft) Connecting Hardware Standards. Flexible locking tabs. Tool-less termination. Suits Clipsal Wall Plates. The Clipsal titanium range of products are the next generation of data communications solutions. These FTP modular jacks are colour coded for both 568A and 568B standards. The FTP Jack features an easy to install tool-less design. These products are designed to fit into all Clipsal Wall Plates without the additional cost of an interfacing bezel. DIMENSIONS Product A B C 30RJ45SM6AF 26mm 23mm 41mm Is backward compatible with Category 5e and 6 products, allowing component mixing without degrading the network below the minimum component category. Flexible locking tabs allow for easy removal from wall plates. Designed to eliminate alien crosstalk (ANEXT). Dielectric Strength 1,000V RMS at 60Hz for 1 minute Current Rating 2 A maximum Insulation Resistance 500MΩ 100V d.c. Contact Resistance 2.5MΩ per contact Temperature Range -40 C to +70 C Transmission Performance TIA/EIA-568-B draft 7.0 channel performance Modular Connector RJ45 8-Pin Connector Durability Material Insulation Diameter (Wire) Connector Material FCC part 68, Subpart F and IEC compliant >750 mating cycles Phosphor bronze with 50 micro- inches of gold over micro-inches nickel plating Suitable insulation of 22 to 24 AWG (0.64 to 0.41mm) mm Phosphor bronze alloy with 100 micro-inch 100% Sn alloy LINE DRAWING 30RJ45SM6AF Connector RJ45 Category 6A FTP 30 Mech (Suits standards Clipsal Wall Plates) 83

6 CLIPSAL DATACOMMS CATEGORY 6A FTP RJ45 SOLUTION JACKS Clipsal titanium Category 6A FTP Jack Keystone A C The Clipsal titanium Series Category 6A FTP Keystone Jack is a superior product delivering the best network performance when used in conjunction with other products in this range. The Clipsal titanium range of products are the next generation of data communications solutions. These FTP modular jacks are colour coded for both 568A and 568B standards. The FTP Jack features an easy to install tool-less design. DIMENSIONS Product A B C RJ45SM6AF 26mm 17mm 41mm Dielectric Strength 1,000V RMS at 60Hz for 1 minute Current Rating 2 A maximum Insulation Resistance 500MΩ 100V d.c. Contact Resistance 2.5MΩ per contact Temperature Range -40 C to +70 C Transmission Performance TIA/EIA-568-C 10 channel and link performance B RJ45SM6AF Fully compliant to AS/NZS 3080:2003, ISO/IEC , ANSI/TIA/EIA-568-C Series and ANSI/TIA/EIA 568-B.2-10 (draft) Connecting Hardware Standards. Flexible locking tabs. Tool-less termination. Is backward compatible with Category 5e and 6 products, allowing component mixing without degrading the network below the minimum component category. Flexible locking tabs allow for easy removal from wall plates. Designed to eliminate alien crosstalk (ANEXT). Modular Connector RJ45 8-Pin Connector Durability Material Insulation Diameter (Wire) Connector Material FCC part 68, Subpart F and IEC compliant >750 mating cycles Phosphor bronze with 50 micro- inches of gold over micro-inches nickel plating Suitable insulation of 22 to 24 AWG (0.64 to 0.41mm) mm Phosphor bronze alloy with 100 micro-inch 100% Sn alloy 84 RJ45SM6AF Connector RJ45 Category 6A FTP Keystone

7 CLIPSAL DATACOMMS CATEGORY 6A FTP RJ45 SOLUTION PATCH PANELS Clipsal titanium Category 6A FTP Patch Panel 24 Port The Clipsal titanium 1RU 19 rack mountable FTP Category 6A patch panel, is specifically designed to meet the highest standards in both performance and functionality. Each panel comes complete with the high performing Clipsal titanium Category 6A keystone FTP connectors that feature time saving tool-less termination and a quick snap-in design for mounting into the patch panel. All Clipsal titanium Category 6A FTP Patch Panels come with the tried and true Clipsal titanium features the market expects from premium products, such as the use of high quality materials in manufacturing, integrated port labelling, full accompaniment of hardware and ties plus any industry leading lifetime warranty program that provides unparalleled peace of mind for the installer and end-user. Dielectric Strength 1,000V RMS at 60Hz for 1 minute Current Rating 2 A maximum Insulation Resistance 500MΩ 100V d.c. Contact Resistance 2.5MΩ per contact Temperature Range -40 C to +70 C Transmission Performance TIA/EIA-568-B draft 7.0 channel performance Modular Connector RJ45 8-Pin Connector Durability Material Insulation Diameter (Wire) Connector Material FCC part 68, Subpart F and IEC compliant >750 mating cycles Phosphor bronze with 50 micro inches of gold over micro-inches nickel plating Suitable insulation of 22 to 24 AWG (0.64 to 0.41mm) mm Phosphor bronze alloy with 100 micro-inch 100% Sn alloy RJ6AA1F24PP Nickle plated and powder coated frame with earthing point. Individual port labelling. Individual snap-in connectors for easy maintenance. Supplied with tool-less connectors for easy installation. Universal colour coding for 568A and 568B Standards. Removable rear cable management tray. Compatible with standard 19 equipment frames. Fully compliant to AS/NZS 3080:2003, ISO/IEC , ANSI/TIA/EIA-568-C Series and ANSI/TIA/EIA- 568-B.2-10 (draft) Connecting Hardware Standards. Complete with all mounting and cable fixing hardware. Rear cable management tray is supplied loose, allowing the installer to fit after termination. The front labelling system provides a clear and efficient means of identifying circuits. Powder coated metal frame is robust and protects the patch panel from corrosion and scratching. RJ6AA1F24PP Patch Panel Category 6A FTP, 24 Port 85

8 CLIPSAL DATACOMMS CATEGORY 6A FTP RJ45 SOLUTION PATCH PANELS Clipsal titanium Category 6A FTP Patch Panel 24 Port Fully Featured The Category 6A FTP Fully Featured Patch Panel incorporates channel designation dials with icons for the top and colours for the bottom of each outlet. It also features hinged label windows (top and bottom) allowing for further identification of each channel designation. Rear cable management tray, velcro cable ties, cage nuts and screws are also provided with the product. Dielectric Strength 1,000V RMS at 60Hz for 1 minute Current Rating 2 A maximum Insulation Resistance 500MΩ 100V d.c. Contact Resistance 2.5MΩ per contact Temperature Range -40 C to +70 C Transmission Performance TIA/EIA-568-B draft 7.0 channel performance Modular Connector RJ45 8-Pin Connector Durability Material Insulation Diameter (Wire) Connector Material FCC part 68, Subpart F and IEC compliant >750 mating cycles Phosphor bronze with 50 micro inches of gold over micro-inches nickel plating Suitable Insulation of 22 to 24 AWG (0.64 to 0.41mm) mm Phosphor bronze alloy with 100 micro-inch 100% Sn alloy RJ6AA1F24KPI Top (icon) and bottom (colour) designated dials. Top and bottom hinged label windows for additional identification. Nickel plated and powder coated frame with earthing point. Individual snap-in connectors for easy maintenance. Supplied with tool-less connectors for easy installation. Universal colour coding for 568A and 568B standards. Removable rear cable management tray. Compatible with standard 19 equipment frames. Fully compliant to AS/NZS 3080:2003, ISO/IEC , ANSI/TIA/EIA-568-C Series and ANSI/TIA/EIA- 568-B.2-10 (draft) Connecting Hardware Standards. Complete with all mounting and cable fixing hardware. Channel designation dials and hinged windows provide an extensive level of designation identification. Rear cable management tray is supplied loose, allowing the installer to fit after termination. Powder coated metal frame is robust and protects the patch panel from corrosion and scratching. 86 RJ6AA1F24KPI Fully Featured Patch Panel Category 6A FTP, 24 Port

9 CLIPSAL DATACOMMS CATEGORY 6A FTP RJ45 SOLUTION CABLE Clipsal titanium Category 6A FTP Cable Clipsal titanium 4-Pair Category 6A FTP Cable delivers excellent network performance when used in conjunction with other Clipsal titanium Category 6A FTP products. The Category 6A FTP cable consists of four pairs of solid insulated copper 23 AWG (0.57mm) and is UL listed. It is designed for use in horizontal cabling situations and supplied in 305m (1,000ft) easy pull out reels. PHYSICAL SPECIFICATIONS Rated Temperature ( C) 75 Product Standard Certification UL Flammability Test FT4 Application Horizontal wiring in LAN Reference Standard UL Subject 444, AS/NZS 3080:2003, ISO/IEC , ANSI/TIA/EIA-568-C Series and ANSI/TIA/EIA-568-B.2-10 (draft) Connecting Hardware Standards, IEC Test Object Test Material PVC Before Tensile Strength (Kg/mm 2 ) 1.05 CONSTRUCTION Conductor Solid bare copper AWG 23 Conductor Dia. Nom. (mm) 0.60 Insulation PE Average Thickness (mm) 0.27 Insulation Diameter (±0.10mm) 1.15 Filler PE PVC Average Thickness (±0.05mm) 0.60 Min. Point Thickness (mm) 0.43 Outer Diameter (±0.2mm) 7.30 Drain Wire YES Shield Aluminium/Polyester Coverage (%) 125% 2D4P6AIPVF3B,BU Conductor Insulation Filler Drain Wire Shield Frequency (MHz) Attenuation (db/100m) NEXT (db) PSNEXT (db) ELFEXT (db/100m) PSELFEXT (db/100m) RL Delay PSANEXT PSAACRF MHz Input Impedance (Ohms) MHz Delay Skew (ns/100m) Pair-to-Ground Capacitance Unbalance (pf/100m) Max. Conductor DC Resistance 20 C (Ohms/km) Resistance Unbalance (%) 100 ± D4P6AIPVF3B,BU LAN Cable Category 6A FTP 305m Box (Blue Only) 87

10 CLIPSAL DATACOMMS CATEGORY 6A FTP RJ45 SOLUTION CABLE Clipsal titanium Category 6A FTP Cable Low Smoke Zero Halogen Clipsal titanium 4 Pair Category 6A FTP Cable delivers excellent network performance when used in conjunction with other Clipsal titanium Category 6A FTP products. The Category 6A FTP cable consists of four pairs of solid insulated copper 23 AWG (0.57mm) and is UL listed with a CM fire rating. It is designed for use in horizontal cabling situations and supplied in 305m (1,000ft) easy pull out boxes. PHYSICAL SPECIFICATION Rated Temperature ( C) 75 Product Standard Certification UL Flammability Test FT4 Application Horizontal wiring in LAN Reference Standard UL Subject 444, AS/NZS 3080:2003, ISO/IEC , ANSI/TIA/EIA-568-C Series and ANSI/TIA/EIA-568-B.2-10 (draft) Connecting Hardware Standards, IEC Test Object Test Material LSZH Before Tensile Strength (Kg/mm 2 ) 1.05 Bend Radius 87 CONSTRUCTION Conductor Solid bare copper AWG 23 Conductor Dia. Nom. (mm) 0.60 Insulation PE Average Thickness (mm) 0.27 Insulation Diameter (±0.10mm) 1.15 Filler PE LSZH Average Thickness (±0.05mm) 0.60 Min. Point Thickness (mm) 0.43 Outer Diameter (±0.2mm) 7.30 Drain Wire YES Shield Aluminium/Polyester Coverage (%) 125% 2D4P6AILSF3B,BU Conductor Insulation Filler Drain Wire Shield 88 Frequency (MHz) Attenuation (db/100m) NEXT (db) PSNEXT (db) ELFEXT (db/100m) PSELFEXT (db/100m) RL Delay PSANEXT PSAACRF D4P6AILSF3B,BU 4 Pair Unscreened UTP Category 6A FTP LSZH Cable, 305m Box (Blue Only) MHz Input Impedance (Ohms) MHz Delay Skew (ns/100m) Pair-to-Ground Capacitance Unbalance (pf/100m) Max. Conductor DC Resistance 20 C (Ohms/km) Resistance Unbalance (%) 100 ±

11 CLIPSAL DATACOMMS CATEGORY 6A FTP RJ45 SOLUTION CABLE MANAGEMENT Clipsal titanium Cable Management Panel Deep The Clipsal titanium Cable Management Panel is a 1 rack unit (1RU) item designed for use in 19 rack environments, managing patch cords that are connected between patch panels and/or active switches. The product is recommended for mounting between every second row of patch panels/active switches. The unique clips provide a quick and simple means of installing the panel in the rack or cabinet. The rings have been designed to facilitate easy insertion and removal of the patch leads, necessary in dynamic environments where moves and changes are required. DIMENSIONS Product A B C RJ1UCMPC 44mm 48mm 100mm Clipsal titanium styling RJ1UCMPC A B Rack Clips for easy mounting C RJ1UCMPC Reinforced cable rings Clip on cover (patented). Rack mount clips eliminate the need for cage nuts and screws. Cavities behind each ring provide additional space for cable slack. Additional depth on cable rings ensures compliance with minimum bend radius requirements. Complements Clipsal titanium patch panel styling. 100mm cable ring depth. Quick product installation using rack mount clips. RJ1UCMPC 1RU Clipsal titanium Cable Management Panel, Deep 89

12 CLIPSAL DATACOMMS CATEGORY 6A FTP RJ45 SOLUTION CABLE MANAGEMENT Clipsal Side Rings The side rings are typically used in frames or cabinets to provide vertical patch cord management. These rings have several features that make them stand out. The ring and lock design utilises proven plastic hinge technology to guide patch cords. These rings have unique teeth locks that are easy to open and snap back to lock tight again should you need to open the rings. The rings can be mounted with patch panels or directly onto the vertical panel mounts (VPM) of the equipment frame. Test Object Ring Material Polypropylene, Graphite Grey RJ1HUDSR DIMENSIONS Product Height Width Depth RJ1HUSSR 42mm 43mm 65mm RJ1HUDSR 42mm 43mm 130mm RJ1HUSSR Graphite Grey. Teeth locks that provide easy access and security for patch cords. Available in 1RU deep and shallow versions. The key benefit is the ring and lock design which not only makes the loading and unloading of patch cords or cables easier but also secures them in place, keeping the cabinet neat and uncluttered. This makes circuit identification and administration for the customer far more efficient. The two rings depths enable the customer to manage the cabinet or rack better depending on the amount of patch cords being used. 90 RJ1HUSSR RJ1HUDSR 1RU Shallow Side Ring 1RU Deep Side Ring

13 CLIPSAL DATACOMMS CATEGORY 6A FTP RJ45 SOLUTION MUTOS MUTOs MULTI USER TELECOMMUNICATIONS OUTLETS (MUTO) Clipsal provides a range of MUTO options which are ideal in situations where a number of terminals are required in the one area. Floor outlet housings can also be used in desktop applications where up to 12 services are required, and fit all standard Clipsal face plates. All Clipsal 2000 Series wall plates will fit into the housing and surrounds of the MUTO's. 224/1 2000/3 Loaded 224/1 Floor Outlet Loaded Faceplate 2000H2 224/1 Floor Outlet Housing for two Standard Plates. Can be used on desktops 224/2 Floor Outlet Housing for four Standard Plates. Can be used on desktops 2000/2 Two Gang Flush Surround, Curved Sides. Suits all 2000 Series grids 2000/3 Three Gang Flush Surround, Curved Sides. Suits all 2000 Series grids 2000/4 Four Gang Flush Surround, Curved Sides. Suits all 2000 Series grids 2000H2 Horizontal Two Gang Flush Surround, Curved Sides. Suits all 2000 Series grids 2000H4 Horizontal Four Gang Flush Surround, Curved Sides. Suits all 2000 Series grids 91

The Next Generation of Data Communicatons Solutions

The Next Generation of Data Communicatons Solutions 19 Systems Enclosures The Next Generation of Data Communicatons Solutions In 2003, Clipsal Datacomms embarked on a research and development program with the intention of introducing a range of products

More information

Compact Module. Category 6A FTP Cabling System 1.1

Compact Module. Category 6A FTP Cabling System 1.1 Updated 24/09/12 Compact Module Cat 6A performance Suitable for 10-Gigabit Ethernet Ultra-slimline design Euro style module Interchangeable with other Euro Modules and blanks Individually QA tested Easy

More information

Multi-Core Fire Resistant Cable

Multi-Core Fire Resistant Cable Fire Resistant Cables / Multi-Core Fire Resistant Cable Approved to UL 444, Zeta ZFP series cables have received UL approval for standard applications. Standards Alarm Cable Z UL 444 Approval CMH Rated

More information

C6 Premium. C6 Premium Copper Systems from Infinique is premium performing Class E / Category 6 Data Communication

C6 Premium. C6 Premium Copper Systems from Infinique is premium performing Class E / Category 6 Data Communication Stable and Reliable Data Communication Solutions from Infinique Infinique provides high quality end-to-end solutions for communication infrastructure that bring great value to its customers. We have achieved

More information

CAT5E DIRECT BURIAL (FLOODED CORE) 24AWG, UTP, 4 PAIR, SOLID 1000 PULL BOX /CMXF

CAT5E DIRECT BURIAL (FLOODED CORE) 24AWG, UTP, 4 PAIR, SOLID 1000 PULL BOX /CMXF POST CAT5E DIRECT BURIAL (FLOODED CORE) 24AWG, UTP, 4 PAIR, SOLID 1000 PULL BOX PART NUMBER: 059-485/CMXF 1 APPROVALS: MARKETING DATE: THE INFORMATION CONTAINED IN THIS DOCUMENT IS PROPRIETARY TO VERTICAL

More information

IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission

IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission ADDISON Flame Retardant CAT5e Data Cables FTX-CAT5e U/UTP4P24 FTX-CAT5e f/utp4p24 FTX-CAT5e sf/utp4p24 LSZH Outer Aluminium/Polyester Tape Solid Copper Conductor PE Insulation Tinned Copper Drain Wire

More information

Caledonian Flame Retardant Coaxial Cables

Caledonian Flame Retardant Coaxial Cables Caledonian Flame Retardant Coaxial Cables www.caledonian-cables.co.uk www.addison-cables.com Flame Retardant RG59 Coaxial cables LSZH Outer Sheath Tinned Copper Braid Aluminium+polyester/Aluminium Tape

More information

Product Specification CAT 6 UNSHIELDED PATCH CORDS

Product Specification CAT 6 UNSHIELDED PATCH CORDS Product 108-93017 Specification 23/Nov/06 Rev. A CAT 6 UNSHIELDED PATCH CORDS 1. SCOPE 1.1 Content This specification describes performance and material requirements and tests procedures for NETCONNECT

More information

Mosaic TM LCS2 Cat. 6A STP RJ 45 socket

Mosaic TM LCS2 Cat. 6A STP RJ 45 socket 870 LIMOGES Cedex Telephone: + 33 0 5 55 06 87 87 - Fax: + 33 0 5 55 06 88 88 Mosaic TM LCS2 socket Page 765 73 794 76 1. General characteristics....1 2. Presentation...1 3. Installation...1 4. Technical

More information

PRODUCT CATALOGUE Norröna

PRODUCT CATALOGUE  Norröna PRODUCT CATALOGUE Norröna WWW.SCANKAB.COM Table of contents MARINE AND OFFSHORE CABLES 1 TOXFREE XZ1-K (AS) - 0.6/1 kv 1 TOXFREE MARINE XO2TCuZ1-K (AS) - 150/250 V 5 4x2xAWG 24/1 CAT6 S/FTP LSZH-SHF1 -

More information

AMP NETCONNECT Category 5E SL Shielded Cabling System. 1. General Description

AMP NETCONNECT Category 5E SL Shielded Cabling System. 1. General Description Category 5E SL Shielded Cabling System Table of Content: 1. General System 7.1. DIN Style Faceplates & Outlets 2. System Cables 7.2. 45x45 MOSAIC Style Faceplates & Outlets 3. Category 5E Shielded SL (SlimLine)

More information

Arteor TM LCS2 Cat. 6A STP RJ 45 socket

Arteor TM LCS2 Cat. 6A STP RJ 45 socket 87045 LIMOGES Cedex Telephone: + 33 0 5 55 06 87 87 - Fax: + 33 0 5 55 06 88 88 Arteor TM Page 5 723 06 5 723 50 1. General characteristics....1 2. Presentation...1 3. Real life scenarios...1 4. Technical

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 61156-6 First edition 2002-03 Multicore and symmetrical pair/quad cables for digital communications Part 6: Symmetrical pair/quad cables with transmission characteristics up

More information

Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design.

Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design. ADDISON Flame Retardant RG59 B/U Coaxial cables Plain copper wire braid PE Solid Bare Copper PVC Outer Sheath APPLICATION The cables are designed for CCTV, security, smoke detection and evacuation monitoring

More information

Arteor TM LCS2 Cat. 6A UTP RJ 45 socket

Arteor TM LCS2 Cat. 6A UTP RJ 45 socket 87045 LIMOGES Cedex Telephone: + 33 0 5 55 06 87 87 - Fax: + 33 0 5 55 06 88 88 Arteor TM Page 5 723 49 5 723 57 1. General characteristics....1 2. Presentation...1 3. Real life scenarios...1 4. Technical

More information

SECTION COMMUNICATIONS HORIZONTAL CABLING

SECTION COMMUNICATIONS HORIZONTAL CABLING SECTION 27 15 00.19 COMMUNICATIONS PART 1 - GENERAL 1.1 SUMMARY A. Section includes the following: 1. Category 6 and Category 5e horizontal UTP cabling. 2. Cable connecting hardware, patch panels, patch

More information

SECTION COMMUNICATIONS FIBER CABINETS, ADAPTERS AND CONNECTORS

SECTION COMMUNICATIONS FIBER CABINETS, ADAPTERS AND CONNECTORS SECTION 27 11 20 COMMUNICATIONS FIBER CABINETS, ADAPTERS AND CONNECTORS PART 1 GENERAL 1.01 DESCRIPTION A. The work covered by this section of the Specifications includes all labor necessary to perform

More information

Special Provision No. 683S28 December 2017

Special Provision No. 683S28 December 2017 FIBRE OPTIC COMMUNICATION CABLES, AERIAL ON MESSENGER CABLE - Item No. FIBRE OPTIC COMMUNICATION CABLES, AERIAL ON MESSENGER CABLE (TEMPORARY) - Item No. Special Provision No. 683S28 December 2017 1. SCOPE

More information

S Low loss coax cables with foamed PE

S Low loss coax cables with foamed PE S Low loss coax cables with foamed PE Cable design Electrical cable data Impedance () 50 Capacitance 82 pf/m Velocity of signal propagation 82 % of the speed of light Epsilon r 1.5 Signal delay 4.1ns/m

More information

Copper LAN cable. This specification describes the general requirements for AMP NETCONNECT* copper LAN cable.

Copper LAN cable. This specification describes the general requirements for AMP NETCONNECT* copper LAN cable. Product Specification 108-93018 25/Aug/2011 Rev H Copper LAN cable 1. SCOPE 1.1. Content This specification describes the general requirements for AMP NETCONNECT* copper LAN cable. 2. APPLICABLE DOCUMENTS

More information

commercial-type cabling and connectivity products into the industrial landscape.

commercial-type cabling and connectivity products into the industrial landscape. Product Bulletin PB 315 Belden DataTuff Industrial Ethernet Connectivity, Tools & Accessories Belden DataTuff Cat 6 and 5e IP67/IP20 Cord Sets, IP67 Modular Jacks, IP67 Plug Kits, Cabling Accessories and

More information

Flame Retardant Overall Screened Instrumentation Cables (multicore)

Flame Retardant Overall Screened Instrumentation Cables (multicore) Flame Retardant Overall Screened Instrumentation Cables (multicore) RE-2X(St)H RE-2X(St)HSWAH LSZH Outer Sheath Tinned Copper Drain Wire LSZH Inner Sheath XLPE Insulation Plain Annealed Copper Aluminium/polyester

More information

SECTION COMMUNICATIONS PATCH CORDS, STATION CORDS AND CROSS CONNECT WIRE

SECTION COMMUNICATIONS PATCH CORDS, STATION CORDS AND CROSS CONNECT WIRE SECTION 27 16 19 COMMUNICATIONS PATCH CORDS, STATION CORDS AND CROSS CONNECT WIRE PART 1 GENERAL 1.01 DESCRIPTION A. The work covered by this section of the Specifications includes all labor necessary

More information

Cat 6 Unshielded Patch cords

Cat 6 Unshielded Patch cords Product Specification 108-93017 13/Oct/2009 Rev D Cat 6 Unshielded s 1. SCOPE 1.1 Content This specification describes performance and material requirements and tests procedures for AMP NETCONNECT* Cat

More information

High Performance LSZH Fire Resistant Cable

High Performance LSZH Fire Resistant Cable High Performance LSZH Fire Resistant Cable www.cavicel.com 104/2 FIRECEL SR 114H is the long and well established CAVICEL fire resistant cable in the market, since many years. These cables are third party

More information

600/1000V SR Insulated Flexibles Control Cables (2-4 Cores & Multicores)

600/1000V SR Insulated Flexibles Control Cables (2-4 Cores & Multicores) 600/1000V SR Insulated Flexibles Control Cables (2-4 Cores & Multicores) FFX400 1SZ1-R(PH60)(CU/SR/LSZH 600/1000V Class 2) FFX400 1SZ1-F(PH60)(CU/SR/LSZH 600/1000V Class 5) Silicone Rubber Insulation Plain

More information

IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission

IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission Flame Retardant RS485 Databus Cables Copper Wire Braid(optional) Individual AL/Polyester Tape(optional) Foam PE/Foam skin PE. Stranded Tinned Copper AL/Polyester Tape With Tinned Copper Drain Wire LSZH

More information

/Oct/2014 Rev B

/Oct/2014 Rev B Product Specification 108-93042 07/Oct/2014 Rev B Class EA shielded solid Patch cords 1. SCOPE 1.1 Content This specification describes performance and material requirements and tests procedures for TE

More information

FIBRE OPTIC COMMUNICATION CABLES, IN DUCTS - Item No. FIBRE OPTIC COMMUNICATION CABLES, IN DUCTS (TEMPORARY) - Item No.

FIBRE OPTIC COMMUNICATION CABLES, IN DUCTS - Item No. FIBRE OPTIC COMMUNICATION CABLES, IN DUCTS (TEMPORARY) - Item No. FIBRE OPTIC COMMUNICATION CABLES, IN DUCTS - Item No. FIBRE OPTIC COMMUNICATION CABLES, IN DUCTS (TEMPORARY) - Item No. Special Provision No. 683S01 December 2017 1. SCOPE This Special Provision covers

More information

Industrial Fiber Optic Cables, LSZH Corrugated Armored Cable, Fibers

Industrial Fiber Optic Cables, LSZH Corrugated Armored Cable, Fibers Features and Benefits Corrugated armor Mechanical protection Low-smoke/zero-halogen (LSZH ) sheath Key life-safety benefit Meets cyclic impact and chemical resistance test Superior performance Tray-rated

More information

Cat 6 Shielded Patch cords

Cat 6 Shielded Patch cords Product Specification 108-93010 14/Oct/2009 Rev E Cat 6 Shielded Patch cords 1. SCOPE 1.1 Content This specification describes performance and material requirements and tests procedures for AMP NETCONNECT*

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 61156-4 Edition 3.0 2009-05 Multicore and symmetrical pair/quad cables for digital communications Part 4: Riser cables Sectional specification INTERNATIONAL ELECTROTECHNICAL

More information

Data sheet OpDAT universal cable 1x24 OM4 - bend insensitive

Data sheet OpDAT universal cable 1x24 OM4 - bend insensitive Illustrations Principle diagram Page 1/7 Product specification installation cable U-DQ(ZN)BH universal fiber optic cable for indoors/outdoors with central or stranded loose tube bend insensitive fiber

More information

FIRE RESISTANT CABLES

FIRE RESISTANT CABLES Conducting Value The Last Cable Standing FIRE RESISTANT CABLES 100/7b ISO 9001:2008 Certificate No. CS1-249 MANAGEMENT SYSTEMS Assessed to ISO 9001:2008 Cert/LPCB ref. 217 GOST ISO 9001-2011 (ISO 9001:2008)

More information

Wire and Cable. For more information on these Tyco Electronics products, visit the following website:

Wire and Cable. For more information on these Tyco Electronics products, visit the following website: 26 Wire and Cable Raychem High Performance Wire and Cable....26-2 to 26-4 Madison Cable Products...................26-5 to 26-7 Reference the following cables in Section 15 of this catalog: Premises Networking

More information

CABLES FOR ALARM AND SAFETY SYSTEMS

CABLES FOR ALARM AND SAFETY SYSTEMS CABLES FOR ALARM AND SAFETY SYSTEMS 2 IT S ALL ABOUT RELIABILITY. It is always important to choose high quality cables, especially when it comes to alarms and safety systems. Even small and seemingly insignificant

More information

2016 CDM Smith All Rights Reserved July 2016 SECTION FIBER OPTIC DATA NETWORK

2016 CDM Smith All Rights Reserved July 2016 SECTION FIBER OPTIC DATA NETWORK PART 1 GENERAL 1.01 SCOPE OF WORK SECTION 27 12 23 FIBER OPTIC DATA NETWORK A. Furnish, install, terminate, and test all fiber optic equipment and cabling necessary for a complete and functional data highway

More information

/Oct/2014 Rev E

/Oct/2014 Rev E Product Specification 108-93017 14/Oct/2014 Rev E Cat 6 Unshielded Patch Cords 1. SCOPE 1.1 Content This specification describes performance and material requirements and tests procedures for TE Connectivity

More information

24 port 0.5U unpopulated FTP keystone panel with cable management bar

24 port 0.5U unpopulated FTP keystone panel with cable management bar 24 port 0.5U unpopulated FTP keystone panel with cable management bar 24 port 0.5U unpopulated FTP keystone panel (FFK24mt0.5su) This 0.5U panel is ideal for high density mounting of 24 shielded or unshielded

More information

Catalogue Telecommunication Cables INTRODUCCIÓN

Catalogue Telecommunication Cables INTRODUCCIÓN Catalogue Telecommunication Cables INTRODUCCIÓN Conductores Tecnológicos S.A. www.contecsa.es Index of Cables Page Introduction 3 EAP / EAP-R 4 EAPSP / EAPSP-R 5 ISP / ICP 6 Conductores Tecnológicos S.A.

More information

Qualification Test Report. AMP-TWIST Series Jacks for Class EA systems

Qualification Test Report. AMP-TWIST Series Jacks for Class EA systems Qualification Test Report 501-93032 14/April/2011 Rev A AMP-TWIST Series Jacks for Class EA systems 1. INTRODUCTION 1.1 Purpose Qualification testing on AMP-TWIST* Series Jacks for Class E A Systems, to

More information

Introduction. Technical Features

Introduction. Technical Features Introduction Powertrain Systems Chassis Systems Safety Systems Security Body Driver Information Convenience The AMPSEAL 16 Connector System is targeted for off-road and heavy duty industrial applications.

More information

Battery Interconnects

Battery Interconnects Battery Interconnects Product Facts Total interface solution Current capacity 7 Amps/ single contact at 30 C T-Rise Choice of right-angle or vertical mount headers with left, right or keyless polarization

More information

HELKAMA. Optical Fibre Cables

HELKAMA. Optical Fibre Cables 1 Contents Optical fibres and their characteristics Cable constructions Cable tests Installation, jointing and terminating Manufacturing (pictures) 2 Multimode Fibre (GK) Attenuation and Bandwidth Fibre

More information

FEB. 17 Rev. A1

FEB. 17 Rev. A1 Product Specification 108-94552 10 FEB. 17 Rev. A1 The product described in this document has not been fully tested to ensure conformance to the requirements outlined below. Therefore, TE Connectivity

More information

Caledonian fire Resistant signal & Data cables

Caledonian fire Resistant signal & Data cables fire Resistant signal & Data cables www.addison-tech.com fire Resistant Rs485 Databus cables Copper Wire Braid(optional) Individual AL/Polyester Tape(optional) Mica Glass Tape+PE/PE+Silicone Rubber Insulation

More information

Z-PACK TinMan 85 ohm Connector Overview

Z-PACK TinMan 85 ohm Connector Overview Z-PACK TinMan 85 ohm High Speed Backplane Connector Z-PACK TinMan 85 ohm Connector Overview Product Facts 10+ Gbps performance 85 ohm impedance for differential pair configuration 5 pair version offers

More information

Caledonian Fire resistant Coaxial Cables

Caledonian Fire resistant Coaxial Cables Caledonian Fire resistant Coaxial Cables www.caledonian-cables.net www.addison-cables.com Fire resistant rg59 b/u Coaxial Cables RG59 B/U FR LSZH Sheath Fire Resistant Tape Copper Clad Steel/Bare Copper

More information

IEC UNE DESIGN. 1. Conductor. 2. Insulation. Cross-linked polyethylene (XLPE) 3. Outer sheath. Flexible PVC, black colour.

IEC UNE DESIGN. 1. Conductor. 2. Insulation. Cross-linked polyethylene (XLPE) 3. Outer sheath. Flexible PVC, black colour. 67 POWERFLEX RV-K POWERFLEX RV-K Industrial flexible cable for power transmission. 1 IEC 60502-1 - UNE 21123-2 DESIGN 1. Conductor 2 Electrolytic copper, class 5 (flexible), based on EN 60228 and IEC 60228.

More information

Mar11 Rev B

Mar11 Rev B Product Specification 108-1576-2 11Mar11 Rev B NETCONNECT*, CHAMP* System 5 Modular Jack Patch Panel 1. SCOPE 1.1. Content This specification covers performance, tests and quality requirements for NETCONNECT*

More information

SECTION COMMUNICATIONS OPTICAL FIBER BACKBONE CABLING

SECTION COMMUNICATIONS OPTICAL FIBER BACKBONE CABLING SECTION 27 13 23 COMMUNICATIONS OPTICAL FIBER PART 1 - GENERAL 1.1 SUMMARY A. Section Includes the following: 1. 50/125-micrometer, optical fiber cabling. 2. Cable connecting hardware, termination panels,

More information

Data sheet OpDAT breakout cable 12x1 OM4 - bend insensitive, class Dca s1 d1 a1

Data sheet OpDAT breakout cable 12x1 OM4 - bend insensitive, class Dca s1 d1 a1 Page 1/9 Illustrations Principle diagram See enlarged drawings at the end of document Product specification connection cable I-V(ZN)HH breakout cable for direct connector termination for indoors and outdoors

More information

Traction Cable Radox 3 GKW

Traction Cable Radox 3 GKW General Properties : Excellent high temperature, low temperature, ozone and weathering resistance, zero halogen, flame retardant, solder iron resistant, easily strippable, flexible. Application : Single

More information

Telephone and Data Structured Wiring

Telephone and Data Structured Wiring Data Specification Category 6A General Telephone and Data Structured Wiring The Electrical Sub-Contractor shall employ a specialist sub-contractor to provide the following systems:- Manufacturer System

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 62255-5 First edition 2005-06 Multicore and symmetrical pair/quad cables for broadband digital communications (high bit rate digital access telecommunication networks) Outside

More information

TELECOMMUNICATIONS CABLING INFRASTRUCTURES - Installation Practice, Inspection and Acceptance

TELECOMMUNICATIONS CABLING INFRASTRUCTURES - Installation Practice, Inspection and Acceptance TELECOMMUNICATIONS CABLING INFRASTRUCTURES - Installation Practice, Inspection and Acceptance Mike Gilmore Standards Activities Member: ISO/IEC JTC1 SC25 WG3: Generic Cabling ISO/IEC JTC1 SC25 Project

More information

Fiber Optic Products Catalog

Fiber Optic Products Catalog Fiber Optic Products Catalog No epoxy, no polish, no crimp Two fibers in one ferrule MT-RJ Patch Panel Jack packages include: 6 MT-RJ Jacks 2 Actuator Tools 1 Fiber Guide 1 Icon Wheel Bend Limiting Boots

More information

SPECIAL ELECTRICAL AND OPTICAL CABLES

SPECIAL ELECTRICAL AND OPTICAL CABLES SPECIAL ELECTRICAL AND OPTICAL CABLES INTRODUCTION The new high-speed trains and the sensible increase of the traffic, with congested lines, is the result of the latest development of the rail sector.

More information

CIR AG Power Cables. CIR AG Control Cable. CIR Type VFD Cable. CIR AG Ratings & Approvals. n UL Listed as Type TC-ER n UL Listed as TC-ER-HL (E123629)

CIR AG Power Cables. CIR AG Control Cable. CIR Type VFD Cable. CIR AG Ratings & Approvals. n UL Listed as Type TC-ER n UL Listed as TC-ER-HL (E123629) Gexol CIR ARCTIC GRADE (AG) Crush and Impact Resistant Without External Armoring Passes the same stringent crush and impact testing required by UL 2225 for Type MC-HL n Shortest Lead Times Standard 8-10

More information

AlarmLine Addressable Linear Heat Detector

AlarmLine Addressable Linear Heat Detector Line Addressable Linear Heat Detector P/N 7-0001-00 Effective: March 2008 K-7-02 FEATURES UL Listed FM Approved CSFM MEA (pending) Low-cost interface between Line sensor cable and control panel accepting

More information

Data sheet OpDAT mini breakout cable 24x1 OM4 - bend insensitive

Data sheet OpDAT mini breakout cable 24x1 OM4 - bend insensitive Page 1/8 Illustrations Principle diagram See enlarged drawings at the end of document Product specification mini-breakout installation cable U-VQ(ZN)H laser-optimized, bend insensitive fiber UV-resistant,

More information

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards Change History Date Description of Change Pages / Sections Modified Change Approver Initials 8/1/17 Updated section on Manufacturers 3 1. 6/15/16 Updated division section from 16120 to 26 05 00, - mgl44

More information

AlarmLine Linear Heat Detector

AlarmLine Linear Heat Detector 7.01 7/11/2000 8:1 AM Page 1 CP Scan#1:Desktop Folder:hold:90 Catalog:7.01.job: 7.01 AlarmLine Linear Heat Detector FEATURES Integrating Type Linear Heat Detector Analog Sensing Field Adjustable Alarm

More information

Telecommunication Cables

Telecommunication Cables Telecommunication Cables Telecommunication Cables Introduction 3 EAP / EAP-R 4 EAPSP / EAPSP-R 5 ISP / ICP 6 Page ELECWIRES 2 www.elecwires.es INTRODUCCIÓN Telecommunication Cables Telephone cables suitable

More information

(Notices) EUROPEAN COMMISSION

(Notices) EUROPEAN COMMISSION 14.8.2012 Official Journal of the European Union C 245/1 IV (Notices) NOTICES FROM EUROPEAN UNION INSTITUTIONS, BODIES, OFFICES AND AGENCIES EUROPEAN COMMISSION Commission communication in the framework

More information

CIR CRUSH & IMPACT RESISTANT ARCTIC GRADE OIL & GAS CABLES

CIR CRUSH & IMPACT RESISTANT ARCTIC GRADE OIL & GAS CABLES CIR CRUSH & IMPACT RESISTANT ARCTIC GRADE OIL & GAS CABLES Gexol CIR ARCTIC GRADE (AG) Crush and Impact Resistant Without External Armoring Passes the same stringent crush and impact testing required by

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK ISO/IEC 17065:2012 to provide product conformity certification Presley Way Crownhill Milton Keynes MK8 0ES Contact: Tracie Hunter Tel: +44 (0)1908 267300 Fax: +44 (0)1908 267255 E-Mail: mail@basec.org.uk

More information

This document is a preview generated by EVS

This document is a preview generated by EVS INTERNATIONAL STANDARD IEC 62255-4 First edition 2005-06 Multicore and symmetrical pair/quad cables for broadband digital communications (high bit rate digital access telecommunication networks) Outside

More information

CIR CRUSH & IMPACT RESISTANT OIL & GAS CABLES

CIR CRUSH & IMPACT RESISTANT OIL & GAS CABLES CIR CRUSH & IMPACT RESISTANT OIL & GAS CABLES Gexol CIR Crush and Impact Resistant Without External Armoring Passes the same stringent crush and impact testing required by UL 2225 for Type MC-HL Index

More information

DNVGL-CP-0402 Edition February 2016

DNVGL-CP-0402 Edition February 2016 CLASS PROGRAMME Type approval DNVGL-CP-0402 Edition February 2016 The electronic pdf version of this document, available free of charge from http://www.dnvgl.com, is the officially binding version. FOREWORD

More information

Core identification code. J-YY...BD Indoor Cable. J-YY...BD Indoor Cable. VDE 0815 Mutual capacitance. J-YY...BD Indoor Cable. Cu conductor 0.

Core identification code. J-YY...BD Indoor Cable. J-YY...BD Indoor Cable. VDE 0815 Mutual capacitance. J-YY...BD Indoor Cable. Cu conductor 0. Indoor cables J-YY...BD Indoor J-Y(ST)Y..LG Indoor Comparable products UNITRONIC J-2Y(ST)Y...ST III BD see page 271 Indoor telephone cables transmit analogue or digital signals In news and communication

More information

USB CONNECTORS MINI USB CONNECTOR & CABLE ESB3,4,5 SERIES. USB CONNECTOR & CABLE ESB0 SERIES (Connector) ESB1 SERIES (Cable)

USB CONNECTORS MINI USB CONNECTOR & CABLE ESB3,4,5 SERIES. USB CONNECTOR & CABLE ESB0 SERIES (Connector) ESB1 SERIES (Cable) USB CONNECTORS USB CONNECTORS MINI USB CONNECTOR & CABLE ESB3,4,5 SERIES USB CONNECTOR & CABLE ESB0 SERIES (Connector) ESB1 SERIES (Cable) IEEE1394 CONNECTOR & CABLE ESB6 SERIES (Connector) ESB2 SERIES

More information

SHIELD TYPE MULTICONDUCTOR MULTIPAIR

SHIELD TYPE MULTICONDUCTOR MULTIPAIR CABLE FINDER GUIDE CONDUCTOR SIZE 18 AWG METRIC 0,97mm 2 SHIELD TYPE MULTICONDUCTOR MULTIPAIR Materials Ratings No. of Alpha Page No. of Alpha Page Cable Type Insulation Jacket Temp. Voltage Conductors

More information

A. The requirements of this Section and the other Division 26, 27 & 28 Sections apply to all the video surveillance system work.

A. The requirements of this Section and the other Division 26, 27 & 28 Sections apply to all the video surveillance system work. PART 1 GNRAL 1.1. APPLICABL PROVISIONS A. The General, Supplementary and other Conditions of the Contract, modifications to the General Conditions, the Drawings, and the applicable provisions of the other

More information

LORAIN CSP DC Power System

LORAIN CSP DC Power System DC Power for Business-Critical Continuity Key Features Compact flexibility provides more space for revenue generating equipment Constant power delivers more current at lower voltages to meet load or recharge

More information

LORAIN CIP 4890/48120 DC Power System

LORAIN CIP 4890/48120 DC Power System DC Power for Business-Critical Continuity Key Features Compact flexibility provides rectifiers, distribution, and controller in one shelf Constant power delivers more current at lower voltages to meet

More information

Plugs & sockets. Industrial plugs and sockets Scame I-1 5. Industrial switched sockets. Scame I-4 6. Distribution boards.

Plugs & sockets. Industrial plugs and sockets Scame I-1 5. Industrial switched sockets. Scame I-4 6. Distribution boards. 7% Plugs & sockets I Industrial plugs and sockets Scame I-1 5 Industrial switched sockets Scame I-4 6 Distribution boards Scame I-7 8 Industrial plug adaptors Scame I-8 Weatherproof switches and sockets

More information

Category 5e Products

Category 5e Products Category 5e Products 25 Year System Performance Coverage* We are confident that your AMP NETCONNECT cabling system will keep performing to current TIA/EIA industry standards. If the registered system ever

More information

Design Requirements Provide work area copper cable (CAT-5 or CAT-6) in accordance with TIA-568-2, with a thermoplastic jacket colored as follows:

Design Requirements Provide work area copper cable (CAT-5 or CAT-6) in accordance with TIA-568-2, with a thermoplastic jacket colored as follows: JBLM Design Standards Design Requirements Provide work area copper cable (CAT-5 or CAT-6) in accordance with TIA-568-2, with a thermoplastic jacket colored as follows: a. RED - SIPR b. BLUE - NIPR (STANDARD

More information

Introduction.

Introduction. Introduction The safety of occupants and users of public, commercial and industrial premises is of paramount importance. One important safety feature is the appropriate use of fire performance cables for

More information

APPLICATIONS. Wireless Communications systems. (LAN, GSM, PCS, WCDMA, UMTS) Remote measuring equipment

APPLICATIONS. Wireless Communications systems. (LAN, GSM, PCS, WCDMA, UMTS) Remote measuring equipment RoHS Ready UMCC Ultraminiature Coax Connector & Cable Assembly Series DESCRIPTION Tyco Electronics introduces the Ultraminiature Coax Connector and Cable Assembly series products. The UMCC series is an

More information

600/1000V XLPE Insulated, LSZH Sheathed, Double steel tape Armoured Power Cables (3 Cores)

600/1000V XLPE Insulated, LSZH Sheathed, Double steel tape Armoured Power Cables (3 Cores) Caledonian Flame Retardant Power & Control Cables www.caledonian-s.co.uk www.addison-s.com 600/1000V XLPE Insulated, LSZH Sheathed, Double steel tape Armoured Power Cables (3 Cores) FTX400 1RZ1MZ1-R (CU/XLPE/LSZH/DSTA/LSZH

More information

SpeedMount Ceiling Speaker System

SpeedMount Ceiling Speaker System SPEAKER SpeedMount Ceiling Speaker System TWO-WAY 7/1 V SPEAKER CARTRIDGE WITH LOW PROFILE PLENUM ENCLOSURE Patented two-piece speaker system for suspended ceilings in division-oflabor installations: CS

More information

POINT OBSTRUCTION CONTROLLER POC TOUCHSCREEN CONTROLLERS

POINT OBSTRUCTION CONTROLLER POC TOUCHSCREEN CONTROLLERS POINT OBSTRUCTION CONTROLLER Compliances: FAA Advisory Circular 70/7460-1L ICAO Annex 14, Volume I, Chapter 6 The controller provides the control and monitoring functions for an LED red obstruction lighting

More information

C-Bus Four Channel Analogue Output Unit Installation Instructions

C-Bus Four Channel Analogue Output Unit Installation Instructions C-Bus Four Channel Analogue Output Unit Installation Instructions 5504AMP Series REGISTERED PATENT Table of Contents Section... Page 1.0 Product Range...3 2.0 Description...3 3.0 Capabilities...3 4.0 Wiring

More information

CS 1226T TWO-WAY 70/100 V SPEEDMOUNT CEILING SPEAKER SYSTEM SPEAKER

CS 1226T TWO-WAY 70/100 V SPEEDMOUNT CEILING SPEAKER SYSTEM SPEAKER SPEAKER CS 1226T TWO-WAY 7/1 V SPEEDMOUNT CEILING SPEAKER SYSTEM Patented two-piece speaker system for suspended ceilings in division-oflabor installations: CS 12P plenum ceiling tile enclosure, 1' x 2'

More information

Jan07 Rev B

Jan07 Rev B Qualification Test Report 501-545 05Jan07 Rev B MT-RJ Patch Panel and Outlet Jacks (Standard, XG, SECURE and SECURE XG) 1. INTRODUCTION 1.1. Purpose Testing was performed on Tyco Electronics MT-RJ Jack,

More information

Section 8: Switchgear Connections (Straight & Elbows)

Section 8: Switchgear Connections (Straight & Elbows) 8: Switchgear Connections (Straight & Elbows) HEAT SHRINKABLE RSRB Inline and Right Angle Bushing Boots 126 PUSH ON ELBOWS RCAB-41 Elastomeric Flexible Bushing Boot - up to 17.5kV 127 RCAB-51 Inline Cold

More information

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 27 COMMUNICATIONS SECTION PUBLIC ADDRESS AND MASS NOTIFICATION SYSTEMS

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 27 COMMUNICATIONS SECTION PUBLIC ADDRESS AND MASS NOTIFICATION SYSTEMS SECTION 275116 - PUBLIC ADDRESS AND MASS NOTIFICATION SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Preamplifiers. 2. Power amplifiers. 3. Microphones. 4. Control console. 5. Loudspeakers.

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60189-2 Fourth edition 2007-05 Low-frequency cables and wires with PVC insulation and PVC sheath Part 2: Cables in pairs, triples, quads and quintuples for inside installations

More information

Fine Pitch SMT Stacking Connectors (Parallel Board-to-Board) Fine Pitch SMT Stacking Connectors (Parallel Board-to-Board) Stacking Height mm inch

Fine Pitch SMT Stacking Connectors (Parallel Board-to-Board) Fine Pitch SMT Stacking Connectors (Parallel Board-to-Board) Stacking Height mm inch Stacking Height Guide for Parallel Board-to-Board Applications Fine Pitch SMT Stacking Stacking Height Guide for Parallel Board-to-Board Applications (Continued) Stacking Height mm inch Connector Description

More information

5. Identification products.

5. Identification products. Essex County College - West Essex Campus Addition And Renovations dib # 54292 / 11-14 [SECTION 260523- CONTROL-VOLTAGE ELECTRICAL POWER CABLES PART 1- GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general

More information

AFIREFENIX SZ1-K 0,6/1 kv PH120 (AS+)

AFIREFENIX SZ1-K 0,6/1 kv PH120 (AS+) Page 1 / 7 Construction and tests. Standards: UNE 211025 Compliance with the Low Voltage Directive (LVD): 2014/35 / EU Construction Products Regulation (CPR) - Regulation (EU) Nº 305/2011: Reaction to

More information

INSTALLATION INSTRUCTIONS FOR 6532 SERIES PACKAGE HEAT PUMP

INSTALLATION INSTRUCTIONS FOR 6532 SERIES PACKAGE HEAT PUMP INSTALLATION INSTRUCTIONS FOR 6532 SERIES PACKAGE HEAT PUMP RV Products A Division of Airxcel, Inc. P.O. Box 4020 Wichita, KS 67204 1976-360 (1-02) PP TABLE OF CONTENTS 1. Warnings......................................................

More information

C-Bus Four Channel General Input Unit Installation Instructions

C-Bus Four Channel General Input Unit Installation Instructions C-Bus Four Channel General Input Unit Installation Instructions 5504GI Series REGISTERED DESIGN REGISTERED PATENT Table of Contents Section...Page 1.0 Product Range... 3 2.0 Description... 3 3.0 Capabilities...

More information

Multipurpose Cables (indoor/outdoor), Multipurpose central tube cable (maxibundle) with glass yarn armouring A-DQ(BN)H 4-24

Multipurpose Cables (indoor/outdoor), Multipurpose central tube cable (maxibundle) with glass yarn armouring A-DQ(BN)H 4-24 Features and Benefits Laminated swelling glass yarns Improved rodent resistance and longitudinal water protection UV and microbe resistant Can be directly buried or installed in ducts Metal-free cable

More information

FIRE RESISTANT CABLES FP200 GOLD

FIRE RESISTANT CABLES FP200 GOLD FIRE RESISTANT CABLES FP200 GOLD FIRE RESISTANT CABLES FP200 GOLD BS7629-1 FP200 GOLD Clause 26.2 > The original highly durable and dressable, easy to terminate and install fire resistant cable. Approved

More information

WaterVue Bluetooth Bathroom Music System

WaterVue Bluetooth Bathroom Music System WaterVue Bluetooth Bathroom Music System User Manual Quick reference guide 1. Important safety instruction............................................ 2 2. Ceiling speaker / in-wall speaker.......................................

More information

INSTALLATION INSTRUCTIONS FOR 6636 SERIES PACKAGE AIR CONDITIONER

INSTALLATION INSTRUCTIONS FOR 6636 SERIES PACKAGE AIR CONDITIONER INSTALLATION INSTRUCTIONS FOR 6636 SERIES PACKAGE AIR CONDITIONER TABLE OF CONTENTS 1. Warnings...................................................... 3 2. Component Match-Up...........................................

More information

Brand Portable Power Cord & Control Cable Solutions

Brand Portable Power Cord & Control Cable Solutions Carol Brand Portable Power Cord & Control Cable Solutions for the Entertainment Market General Cable s Carol Brand portable power cord and control cable solutions are manufactured for use in the entertainment