Caledonian Flame Retardant Coaxial Cables

Size: px
Start display at page:

Download "Caledonian Flame Retardant Coaxial Cables"

Transcription

1 Caledonian Flame Retardant Coaxial Cables Flame Retardant RG59 Coaxial cables LSZH Outer Sheath Tinned Copper Braid Aluminium+polyester/Aluminium Tape PE Solid Bare Copper LSZH Inner Sheath Tinned Copper Drain Wire Braid or Wire Armoured APPLICATION The cables are designed for CCTV, security, smoke detection and evacuation monitoring applications, where continued functionality is required during a fire situation. Due to the zero halogen low smoke construction, this cable is ideal for use in public, commercial and industrial environments. STANDARDS Basic design to MIL-C-17 FIRE PERFORMANCE Flame Retardance (Single Vertical Wire Test) (Vertically-mounted bundled wires & cable test) EN ; IEC ; BS EN ; VDE ; NBN C (cat. F1); NF C (C2); CEI 20-35/1-2; EN *; DIN VDE * EN (cat. C); IEC ; BS EN ; VDE ; NBN C (cat. F2); NF C (C1); CEI 20-22/3-4; EN *; DIN VDE IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission IEC ; EN ; DIN VDE ; CEI 20-37/2-2 ; BS * Minimum Smoke Emission IEC &2; EN &2; DIN VDE &2; CEI 20-37/3-1&2; EN &2*; BS &2* No Toxic gases NES ; NF C Note: Asterisk * denotes superseded standard. CABLE CONSTRUCTION Conductors: Copper clad steel, solid according to IEC(EN) class 1. Insulation: PE compound. Overall Screen: Plain copper wire braid Outer Sheath: Thermoplastic LSZH compound type LTS3 as per BS (Thermosetting LSZH compound type SW2-SW4 as per BS can be offered.) ADDISON 121

2 ADDISON Physical AND THERMAL PROPERTIES Temperature range during operation (fixed state): -30 C C Temperature range during installation (mobile state): -5ºC - +60ºC Minimum bending radius: 8 x Overall Electrical Properties Impedance 75±5Ω Capacitance 67 nf/km Velocity ratio(%) 66 Insulation resistance >2000 Mohm.Km Shield coverage 95% DC resistance Inner conductor 158 Ω/km Outer conductor 9.0 Ω/km Attenuation Frequency(MHz) Attenuation (db/100 m) Attenuation (db/100ft) Return Loss Frequency(MHz) Return Loss (db) MHz >31dB MHz >28dB MHz >24dB 122 Caledonian

3 Caledonian Flame Retardant Coaxial Cables CONSTRUCTION PARAMETERS Cable Code Conductor Insulation Screen No.x Overall Approx. Weight mm mm No. x mm mm kg/km RG59 B/U 0.58 ± ± 0.10 m 120 x /500V Rated Voltage MIL-C-17 N Standard Flame Retardancy NF C (C1) NF C (C2) IEC IEC /EN EN Zero Low Toxicity NES /NF C Low Corrosivity IEC EN /3 NF C Low Smoke Emission IEC &2 EN &2/NF C IEC EN ADDISON 123

4 ADDISON Flame Retardant RG59 CWB/SWB/SWA Armoured Coaxial cables LSZH Outer Sheath Tinned Copper Braid Aluminium+polyester/Aluminium Tape PE Solid Bare Copper LSZH Inner Sheath Tinned Copper Drain Wire Braid or Wire Armoured Application These 75Ω coaxial cables are suitable for installation on board of ships and other indoor marine environments. STANDARDS Basic design to MIL-C-17 FIRE PERFORMANCE Flame Retardance (Single Vertical Wire Test) (Vertically-mounted bundled wires & cable test) EN ; IEC ; BS EN ; VDE ; NBN C (cat. F1); NF C (C2); CEI 20-35/1-2; EN *; DIN VDE * EN (cat. C); IEC ; BS EN ; VDE ; NBN C (cat. F2); NF C (C1); CEI 20-22/3-4; EN *; DIN VDE IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission IEC ; EN ; DIN VDE ; CEI 20-37/2-2 ; BS * Minimum Smoke Emission IEC &2; EN &2; DIN VDE &2; CEI 20-37/3-1&2; EN &2*; BS &2* No Toxic gases NES ; NF C Note: Asterisk * denotes superseded standard. CABLE CONSTRUCTION Conductors: 20AWG solid bare copper. Insulation: PE compound. Screen1: Aluminium/polyester or aluminium tape. Screen2: Tinned copper braid. 124 Caledonian

5 Caledonian Flame Retardant Coaxial Cables Inner Sheath: Low smoke and halogen-free polyolefin, coloured black. Armouring: cwb: copper Wire Braid swb: Steel Wire Braid swa: Steel Wire Armour Outer Sheath: Thermoplastic LSZH compound type LTS3 as per BS (Thermosetting LSZH compound type SW2-SW4 as per BS can be offered.) Physical AND THERMAL PROPERTIES Temperature Range: -30 C C Minimum Bending Radius: 15 X Overall Electrical Properties AWG 20 Conductor mm 0.8 Impedance Ω 75+/-5 Attenuation@100MHz db/100m 7.6 Attenuation@270MHz db/100m 12.5 Attenuation@540MHz db/100m 17.9 Attenuation@720MHz db/100m 20.9 Attenuation@750MHz db/100m 21.3 Attenuation@1000MHz db/100m 24.9 Capacitance pf/m 53.5 Velocity of Propagation % 83 Conductor DCR Ω/km 32.8 Shield DCR Ω/km 12.5 Inductance μh/m Time Delay ns/m 4.0 ADDISON 125

6 ADDISON CONSTRUCTION PARAMETERS Cable Code Inner Conductor Insulation Outer Sheath Overall Weight Thickness Thickness mm mm mm mm kg/km RG59 CWB RG59 SWB RG59 SWA /500V Rated Voltage MIL-C-17 N Standard Flame Retardancy NF C (C1) NF C (C2) IEC IEC /EN EN Zero Low Toxicity NES /NF C Low Corrosivity IEC EN /3 NF C Low Smoke Emission IEC &2 EN &2/NF C IEC EN Caledonian

7 Caledonian Flame Retardant Coaxial Cables Flame Retardant RG6 Coaxial cables LSZH Outer Sheath Bare Copper PE AL Foil+AL Braid APPLICATION The cables are designed for CCTV, security, smoke detection and evacuation monitoring applications, where continued functionality is required during a fire situation. Due to the zero halogen low smoke construction, this cable is ideal for use in public, commercial and industrial environments. STANDARDS Basic design to MIL-C-17 FIRE PERFORMANCE Flame Retardance (Single Vertical Wire Test) (Vertically-mounted bundled wires & cable test) EN ; IEC ; BS EN ; VDE ; NBN C (cat. F1); NF C (C2); CEI 20-35/1-2; EN *; DIN VDE * EN (cat. C); IEC ; BS EN ; VDE ; NBN C (cat. F2); NF C (C1); CEI 20-22/3-4; EN *; DIN VDE IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission IEC ; EN ; DIN VDE ; CEI 20-37/2-2 ; BS * Minimum Smoke Emission IEC &2; EN &2; DIN VDE &2; CEI 20-37/3-1&2; EN &2*; BS &2* No Toxic gases NES ; NF C Note: Asterisk * denotes superseded standard. CABLE CONSTRUCTION Conductors: Bare copper copper wire, solid according to IEC(EN) class 1. Insulation: Foamed PE compound. Overall Screen: Aluminium foil(100%)+aluminium braid (70%) Outer Sheath: Thermoplastic LSZH compound type LTS3 as per BS (Thermosetting LSZH compound type SW2-SW4 as per BS can be offered.) ADDISON 127

8 ADDISON Physical AND THERMAL PROPERTIES Temperature Range During Operation (Fixed State): -30 C C Temperature Range During Installation (Mobile State): -5 C C Minimum Bending Radius: 8 X Overall Electrical Properties Impedance 75±5Ω Capacitance 54 nf/km Velocity ratio(%) 82 Insulation resistance >5000 Mohm.Km Shield coverage AL foil(100%)+al 70% DC resistance Inner conductor 23.1 Ω/km Outer conductor 31 Ω/km Attenuation Frequency(MHz) Attenuation (db/100 m) Attenuation (db/100ft) Return Loss Frequency(MHz) Return Loss (db) >28dB >24dB >22dB 128 Caledonian

9 Caledonian Flame Retardant Coaxial Cables CONSTRUCTION PARAMETERS Cable Code Conductor Insulation Screen No.x Overall Approx. Weight mm mm No. x mm mm kg/km RG6 A/U ± x /500V Rated Voltage MIL-C-17 N Standard Flame Retardancy NF C (C1) NF C (C2) IEC IEC /EN EN Zero Low Toxicity NES /NF C Low Corrosivity IEC EN /3 NF C Low Smoke Emission IEC &2 EN &2/NF C IEC EN ADDISON 129

10 ADDISON Flame Retardant RG6 CWB/SWB/SWA Armoured Coaxial cables LSZH Outer Sheath Tinned Copper Braid Aluminium+polyester/Aluminium Tape PE Solid Bare Copper LSZH Inner Sheath Tinned Copper Drain Wire Braid or Wire Armoured Application These 75Ω coaxial cables are suitable for installation on board of ships and other indoor marine environments. STANDARDS Basic design to MIL-C-17 FIRE PERFORMANCE Flame Retardance (Single Vertical Wire Test) (Vertically-mounted bundled wires & cable test) EN ; IEC ; BS EN ; VDE ; NBN C (cat. F1); NF C (C2); CEI 20-35/1-2; EN *; DIN VDE * EN (cat. C); IEC ; BS EN ; VDE ; NBN C (cat. F2); NF C (C1); CEI 20-22/3-4; EN *; DIN VDE IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission IEC ; EN ; DIN VDE ; CEI 20-37/2-2 ; BS * Minimum Smoke Emission IEC &2; EN &2; DIN VDE &2; CEI 20-37/3-1&2; EN &2*; BS &2* No Toxic gases NES ; NF C Note: Asterisk * denotes superseded standard. CABLE CONSTRUCTION Conductors: 18AWG solid bare copper. Insulation: PE compound. Screen1: Aluminium/polyester or aluminium tape. Screen2: Tinned copper braid. Inner Sheath: Low smoke and halogen-free polyolefin, coloured black. Armour: cwb: copper Wire Braid swb: Steel Wire Braid swa: Steel Wire Armour 130 Caledonian

11 Caledonian Flame Retardant Coaxial Cables Outer Sheath: Thermoplastic LSZH compound type LTS3 as per BS (Thermosetting LSZH compound type SW2-SW4 as per BS 7655:section 2.6 can be offered.) Physical AND THERMAL PROPERTIES Temperature Range: -30 C C Minimum Bending Radius: 815 X Overall Electrical Properties AWG 18 Conductor mm 1.0 Impedance Ω 75+/-5 Attenuation@100MHz db/100m 6.9 Attenuation@200MHz db/100m 9.0 Attenuation@300MHz db/100m 11.8 Attenuation@400MHz db/100m 13.1 Attenuation@500MHz db/100m 15.4 Attenuation@900MHz db/100m 21.5 Attenuation@1700MHz db/100m 29.4 Capacitance pf/m 53.5 Velocity of Propagation % 83 Conductor DCR Ω/km 21.4 Shield DCR Ω/km 7.5 Inductance μh/m 0.32 Time Delay ns/m 4 ADDISON 131

12 ADDISON CONSTRUCTION PARAMETERS Cable Code Inner Conductor Insulation Thickness Sheath Thickness Overall Weight mm mm mm mm kg/km RG6 CWB RG6 SWB RG6 SWA /500V Rated Voltage MIL-C-17 N Standard Flame Retardancy NF C (C2) IEC /EN NF C (C1) IEC EN Zero Low Toxicity NES /NF C Low Corrosivity IEC EN /3 NF C Low Smoke Emission IEC &2 EN &2/NF C IEC EN Caledonian

13 Caledonian Flame Retardant Coaxial Cables Flame Retardant RG11 Coaxial Cables Plain Copper Wire Braid Screen PE Tinned Copper Binder LSZH Outer Sheath APPLICATION The cables are designed for CCTV, security, smoke detection and evacuation monitoring applications, where continued functionality is required during a fire situation. Due to the zero halogen low smoke construction, this cable is ideal for use in public, commercial and industrial environments. STANDARDS Basic design to MIL-C-17 FIRE PERFORMANCE Flame Retardance (Single Vertical Wire Test) (Vertically-mounted bundled wires & cable test) EN ; IEC ; BS EN ; VDE ; NBN C (cat. F1); NF C (C2); CEI 20-35/1-2; EN *; DIN VDE * EN (cat. C); IEC ; BS EN ; VDE ; NBN C (cat. F2); NF C (C1); CEI 20-22/3-4; EN *; DIN VDE IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission IEC ; EN ; DIN VDE ; CEI 20-37/2-2 ; BS * Minimum Smoke Emission IEC &2; EN &2; DIN VDE &2; CEI 20-37/3-1&2; EN &2*; BS &2* No Toxic gases NES ; NF C Note: Asterisk * denotes superseded standard. CABLE CONSTRUCTION Conductors: Tinned copper wire, stranded according to IEC(EN) class 2. Insulation: Low density PE. ADDISON 133

14 ADDISON Overall Screen: Plain copper wire braid Outer Sheath: Thermoplastic LSZH compound type LTS3 as per BS (Thermosetting LSZH compound type SW2-SW4 as per BS 7655:section 2.6 can be offered.) Physical AND THERMAL PROPERTIES Temperature Range During Operation (Fixed State): -30 C C Temperature Range During Installation (Mobile State): -5 C C Minimum Bending Radius: 8 X Overall Electrical Properties Impedance 75±5Ω Capacitance Velocity ratio(%) 66 Insulation resistance Shield coverage 97% DC resistance Inner conductor Outer conductor Attenuation 67 nf/km >2000 Mohm.Km 20.5 Ω/km 4.5 Ω/km Frequency(MHz) Attenuation (db/100 m) Attenuation (db/100ft) Return Loss Frequency(MHz) Return Loss (db) MHz >30dB MHz >27dB MHz >25dB 134 Caledonian

15 Caledonian Flame Retardant Coaxial Cables CONSTRUCTION PARAMETERS Cable Code Conductor Insulation Screen No.x Overall Approx. Weight mm mm No. x mm mm kg/km RG11 A/U 7 x ± x ± /500V Rated Voltage MIL-C-17 N Standard Flame Retardancy NF C (C1) NF C (C2) IEC IEC /EN EN Zero Low Toxicity NES /NF C Low Corrosivity IEC EN /3 NF C Low Smoke Emission IEC &2 EN &2/NF C IEC EN ADDISON 135

16 ADDISON Flame Retardant RG11 CWB/SWB/SWA Armoured Coaxial Cables LSZH Outer Sheath Tinned Copper Braid Aluminium+polyester/Aluminium Tape PE Solid Bare Copper LSZH Inner Sheath Tinned Copper Drain Wire Braid or Wire Armoured APPLICATION These 75Ω coaxial cables are suitable for installation on board of ships and other indoor marine environments. STANDARDS Basic design to MIL-C-17 FIRE PERFORMANCE Flame Retardance (Single Vertical Wire Test) (Vertically-mounted bundled wires & cable test) EN ; IEC ; BS EN ; VDE ; NBN C (cat. F1); NF C (C2); CEI 20-35/1-2; EN *; DIN VDE * EN (cat. C); IEC ; BS EN ; VDE ; NBN C (cat. F2); NF C (C1); CEI 20-22/3-4; EN *; DIN VDE IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission IEC ; EN ; DIN VDE ; CEI 20-37/2-2 ; BS * Minimum Smoke Emission IEC &2; EN &2; DIN VDE &2; CEI 20-37/3-1&2; EN &2*; BS &2* No Toxic gases NES ; NF C Note: Asterisk * denotes superseded standard. CABLE CONSTRUCTION Conductors: 14AWG solid bare copper. Insulation: Low density PE compound. Screen1: Aluminium/polyester or aluminium tape. Screen2: Tinned copper braid. Inner Sheath: Low smoke and halogen-free polyolefin, coloured black. Armour: cwb: copper Wire Braid 136 Caledonian

17 Caledonian Flame Retardant Optic Fiber Cables swb: Steel Wire Braid swa: Steel Wire Armour Outer Sheath: Thermoplastic LSZH compound type LTS3 as per BS (Thermosetting LSZH compound type SW2-SW4 as per BS 7655:section 2.6 can be offered.) Physical AND THERMAL PROPERTIES Temperature range during operation (fixed state): -30 C C Minimum bending radius: 15 x Overall Electrical Properties AWG 14 Conductor mm 1.6 Impedance Ω 75+/-5 Attenuation@100MHz db/100m 4.5 Attenuation@270MHz db/100m 7.6 Attenuation@540MHz db/100m 10.8 Attenuation@750MHz db/100m 12.8 Attenuation@1000MHz db/100m 14.8 Capacitance pf/m 53.5 Velocity of Propagation % 83 Conductor DCR Ω/km 8.5 Shield DCR Ω/km 12.1 Inductance μh/m 0.32 Time Delay ns/m 4 ADDISON 137

18 ADDISON CONSTRUCTION PARAMETERS Cable Code Inner Conductor Insulation Sheath Overall Weight Thickness Thickness mm mm mm mm kg/km RG11 CWB RG11 SWB RG11 SWA /500V Rated Voltage MIL-C-17 N Standard Flame Retardancy NF C (C2) IEC /EN NF C (C1) IEC EN Zero Low Toxicity NES /NF C Low Corrosivity IEC EN /3 NF C Low Smoke Emission IEC &2 EN &2/NF C IEC EN Caledonian

Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design.

Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design. ADDISON Flame Retardant RG59 B/U Coaxial cables Plain copper wire braid PE Solid Bare Copper PVC Outer Sheath APPLICATION The cables are designed for CCTV, security, smoke detection and evacuation monitoring

More information

Caledonian Fire resistant Coaxial Cables

Caledonian Fire resistant Coaxial Cables Caledonian Fire resistant Coaxial Cables www.caledonian-cables.net www.addison-cables.com Fire resistant rg59 b/u Coaxial Cables RG59 B/U FR LSZH Sheath Fire Resistant Tape Copper Clad Steel/Bare Copper

More information

IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission

IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission ADDISON Flame Retardant CAT5e Data Cables FTX-CAT5e U/UTP4P24 FTX-CAT5e f/utp4p24 FTX-CAT5e sf/utp4p24 LSZH Outer Aluminium/Polyester Tape Solid Copper Conductor PE Insulation Tinned Copper Drain Wire

More information

IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission

IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission Flame Retardant RS485 Databus Cables Copper Wire Braid(optional) Individual AL/Polyester Tape(optional) Foam PE/Foam skin PE. Stranded Tinned Copper AL/Polyester Tape With Tinned Copper Drain Wire LSZH

More information

600/1000V XLPE Insulated, LSZH Sheathed, Double steel tape Armoured Power Cables (3 Cores)

600/1000V XLPE Insulated, LSZH Sheathed, Double steel tape Armoured Power Cables (3 Cores) Caledonian Flame Retardant Power & Control Cables www.caledonian-s.co.uk www.addison-s.com 600/1000V XLPE Insulated, LSZH Sheathed, Double steel tape Armoured Power Cables (3 Cores) FTX400 1RZ1MZ1-R (CU/XLPE/LSZH/DSTA/LSZH

More information

Caledonian fire Resistant signal & Data cables

Caledonian fire Resistant signal & Data cables fire Resistant signal & Data cables www.addison-tech.com fire Resistant Rs485 Databus cables Copper Wire Braid(optional) Individual AL/Polyester Tape(optional) Mica Glass Tape+PE/PE+Silicone Rubber Insulation

More information

Flame Retardant Overall Screened Instrumentation Cables (multicore)

Flame Retardant Overall Screened Instrumentation Cables (multicore) Flame Retardant Overall Screened Instrumentation Cables (multicore) RE-2X(St)H RE-2X(St)HSWAH LSZH Outer Sheath Tinned Copper Drain Wire LSZH Inner Sheath XLPE Insulation Plain Annealed Copper Aluminium/polyester

More information

600/1000V SR Insulated Flexibles Control Cables (2-4 Cores & Multicores)

600/1000V SR Insulated Flexibles Control Cables (2-4 Cores & Multicores) 600/1000V SR Insulated Flexibles Control Cables (2-4 Cores & Multicores) FFX400 1SZ1-R(PH60)(CU/SR/LSZH 600/1000V Class 2) FFX400 1SZ1-F(PH60)(CU/SR/LSZH 600/1000V Class 5) Silicone Rubber Insulation Plain

More information

600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (Multicore)

600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (Multicore) 600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (Multicore) FGD400 1RV-R (CU/XLPE/PVC 600/1000V Class ) FGD400 1RVMV-R (CU/XLPE/PVC/SWA/PVC 600/1000V Class ) PVC Outer Sheath Plain Annealed

More information

FIRE RESISTANT CABLES

FIRE RESISTANT CABLES Conducting Value The Last Cable Standing FIRE RESISTANT CABLES 100/7b ISO 9001:2008 Certificate No. CS1-249 MANAGEMENT SYSTEMS Assessed to ISO 9001:2008 Cert/LPCB ref. 217 GOST ISO 9001-2011 (ISO 9001:2008)

More information

High Performance LSZH Fire Resistant Cable

High Performance LSZH Fire Resistant Cable High Performance LSZH Fire Resistant Cable www.cavicel.com 104/2 FIRECEL SR 114H is the long and well established CAVICEL fire resistant cable in the market, since many years. These cables are third party

More information

PRODUCT CATALOGUE Norröna

PRODUCT CATALOGUE  Norröna PRODUCT CATALOGUE Norröna WWW.SCANKAB.COM Table of contents MARINE AND OFFSHORE CABLES 1 TOXFREE XZ1-K (AS) - 0.6/1 kv 1 TOXFREE MARINE XO2TCuZ1-K (AS) - 150/250 V 5 4x2xAWG 24/1 CAT6 S/FTP LSZH-SHF1 -

More information

Multi-Core Fire Resistant Cable

Multi-Core Fire Resistant Cable Fire Resistant Cables / Multi-Core Fire Resistant Cable Approved to UL 444, Zeta ZFP series cables have received UL approval for standard applications. Standards Alarm Cable Z UL 444 Approval CMH Rated

More information

Photovoltaic Cables EN H1Z2Z2-K

Photovoltaic Cables EN H1Z2Z2-K Photovoltaic Cables EN 50618 H1Z2Z2-K COMPANY PROFILE Caledonian, established in 1978, offers one of the most complete lines of fiber and copper cabling system solutions with over hundreds of different

More information

Caledonian. FIREFLIX ire Resistant Coaxial Cables

Caledonian. FIREFLIX ire Resistant Coaxial Cables Caledonian FIREFLIX ire Resistant Coaxial Cables table OF COntents Fire resistant Coaxial Cables Fire Resistant RG59 B/U coaxial cables...25 Fire Resistant RG6 A/U coaxial cables...28 Fire Resistant RG6

More information

Firecel Safety Cables

Firecel Safety Cables 103/7 Firecel Safety Cables Low Smoke - Zero Halogen www.cavicel.com Firecel Safety Cables Low Smoke - Zero Halogen Over the last 30 years CAVICEL has developped a deep experience in studying, designing

More information

BS /1000V XLPE Insulation LSZH Sheath Cables

BS /1000V XLPE Insulation LSZH Sheath Cables BS 8573 600/1000V XLPE Insulation LSZH Sheath Cables Caledonian www.addison-cables.com Company Profile Caledonian & Addison, branded under Caledoniea & Addimax, established in 1978, offers one of the most

More information

SPECIAL ELECTRICAL AND OPTICAL CABLES

SPECIAL ELECTRICAL AND OPTICAL CABLES SPECIAL ELECTRICAL AND OPTICAL CABLES INTRODUCTION The new high-speed trains and the sensible increase of the traffic, with congested lines, is the result of the latest development of the rail sector.

More information

Introduction.

Introduction. Introduction The safety of occupants and users of public, commercial and industrial premises is of paramount importance. One important safety feature is the appropriate use of fire performance cables for

More information

SAS Security and Alarm Safety Cables

SAS Security and Alarm Safety Cables CABLES Security and Alarm Safety Cables Security and Alarm Safety Cables LOW SMOKE ZERO HALOGEN The right range of cables for modern building installations e-catalogue 203/4 Flexible solutions for commercial,

More information

Firetuf Cables ZERO HALOGEN, LOW SMOKE (0HLS ) CABLE

Firetuf Cables ZERO HALOGEN, LOW SMOKE (0HLS ) CABLE Firetuf Cables ZERO HALOGEN, LOW SMOKE (0HLS ) CABLE Draka, the world s mo When it comes to specifying fire performance cables, zero halogen building wires and power cables, you have to choose products

More information

Firetuf Cables ZERO HALOGEN, LOW SMOKE (0HLS ) CABLE

Firetuf Cables ZERO HALOGEN, LOW SMOKE (0HLS ) CABLE Firetuf Cables ZERO HALOGEN, LOW SMOKE (0HLS ) CABLE Draka, the world s most trusted cable brand When it comes to specifying fire performance cables, zero halogen building wires and power cables, you have

More information

Compact Module. Category 6A FTP Cabling System 1.1

Compact Module. Category 6A FTP Cabling System 1.1 Updated 24/09/12 Compact Module Cat 6A performance Suitable for 10-Gigabit Ethernet Ultra-slimline design Euro style module Interchangeable with other Euro Modules and blanks Individually QA tested Easy

More information

Fire alarm cables. for highest safety requirements TRADITION INNOVATION PASSION

Fire alarm cables. for highest safety requirements TRADITION INNOVATION PASSION Fire alarm cables for highest safety requirements TRADITION INNOVATION PASSION Datwyler Datwyler Cabling Solutions is an internationally operating company with its headquarters in Switzerland and affiliates

More information

CATEGORY 6A FTP RJ45 SOLUTION

CATEGORY 6A FTP RJ45 SOLUTION CATEGORY 6A FTP RJ45 SOLUTION Clipsal titanium Patch Cord Clipsal titanium LSZH Patch Cord Clipsal titanium Keystone Jacks Clipsal titanium Modular Jacks Clipsal titanium Patch Panels Clipsal titanium

More information

The Quality Connection. BETAflam Fire Resistant Safety Cables

The Quality Connection. BETAflam Fire Resistant Safety Cables The Quality Connection BETAflam Fire Resistant Safety Cables BETAflam Contact Your personal customer number To offer you a more efficient service, we kindly ask you to mention your personal customer number

More information

Table of Contents. TELE-FONIKA KABLE SA (DMCC Branch). 4 TELE-FONIKA Kable Group 6 FLAME-X 950 SERIES 1 11 FLAME-X 950 SERIES 2

Table of Contents. TELE-FONIKA KABLE SA (DMCC Branch). 4 TELE-FONIKA Kable Group 6 FLAME-X 950 SERIES 1 11 FLAME-X 950 SERIES 2 FLAME-X 950 TELE-FONIKA KABLE SA (DMCC Branch). Table of Contents is the Regional Middle East Sales Office of Tele-Fonika Kable S.A. from Poland, 4-th largest manufacturer of electric cables and wires

More information

Core identification code. J-YY...BD Indoor Cable. J-YY...BD Indoor Cable. VDE 0815 Mutual capacitance. J-YY...BD Indoor Cable. Cu conductor 0.

Core identification code. J-YY...BD Indoor Cable. J-YY...BD Indoor Cable. VDE 0815 Mutual capacitance. J-YY...BD Indoor Cable. Cu conductor 0. Indoor cables J-YY...BD Indoor J-Y(ST)Y..LG Indoor Comparable products UNITRONIC J-2Y(ST)Y...ST III BD see page 271 Indoor telephone cables transmit analogue or digital signals In news and communication

More information

Cable technology for highest safety requirements

Cable technology for highest safety requirements Cable technology for highest safety requirements Daetwyler We are a provider of high-grade quality system solutions and services in the areas of structured data cabling, telecom carriers, safety cabling,

More information

Catalogue Telecommunication Cables INTRODUCCIÓN

Catalogue Telecommunication Cables INTRODUCCIÓN Catalogue Telecommunication Cables INTRODUCCIÓN Conductores Tecnológicos S.A. www.contecsa.es Index of Cables Page Introduction 3 EAP / EAP-R 4 EAPSP / EAPSP-R 5 ISP / ICP 6 Conductores Tecnológicos S.A.

More information

S Low loss coax cables with foamed PE

S Low loss coax cables with foamed PE S Low loss coax cables with foamed PE Cable design Electrical cable data Impedance () 50 Capacitance 82 pf/m Velocity of signal propagation 82 % of the speed of light Epsilon r 1.5 Signal delay 4.1ns/m

More information

Catalogue. Instrumentation & Control Cables

Catalogue. Instrumentation & Control Cables Catalogue Instrumentation & Control Cables Conductores Tecnológicos S.A. www.contecsa.es Index of Cables Page Introduction 3 Instrumentation VOV 4 VHOV 5 VOVMV 6 VHOVMV 7 Control RV 8 RZ1C3Z1 9 Conductores

More information

Traction Cable Radox 3 GKW

Traction Cable Radox 3 GKW General Properties : Excellent high temperature, low temperature, ozone and weathering resistance, zero halogen, flame retardant, solder iron resistant, easily strippable, flexible. Application : Single

More information

Power Cables. Introduction 3 RV 4 RVMV 5 RVSV 6 RVFV 7. ELECWIRES 2 Page

Power Cables. Introduction 3 RV 4 RVMV 5 RVSV 6 RVFV 7. ELECWIRES 2  Page Power Cables Power Cables Page Introduction 3 RV 4 RVMV 5 RVSV 6 RVFV 7 ELECWIRES 2 www.elecwires.es INTRODUCTION Power Cables Power cables for electrical installations, domestic & industrial, specifically

More information

Catalogue Power Cables

Catalogue Power Cables Catalogue Power Cables Conductores Tecnológicos S.A. www.contecsa.es Index of Cables Page Introduction 13 RV 14 RVMV 15 RVSV 16 RVFV 17 Conductores Tecnológicos S.A. 2 www.contecsa.es INTRODUCTION Power

More information

AFIREFENIX SZ1-K 0,6/1 kv PH120 (AS+)

AFIREFENIX SZ1-K 0,6/1 kv PH120 (AS+) Page 1 / 7 Construction and tests. Standards: UNE 211025 Compliance with the Low Voltage Directive (LVD): 2014/35 / EU Construction Products Regulation (CPR) - Regulation (EU) Nº 305/2011: Reaction to

More information

Telecommunication Cables

Telecommunication Cables Telecommunication Cables Telecommunication Cables Introduction 3 EAP / EAP-R 4 EAPSP / EAPSP-R 5 ISP / ICP 6 Page ELECWIRES 2 www.elecwires.es INTRODUCCIÓN Telecommunication Cables Telephone cables suitable

More information

Double insulated, electron-beam cross-linked, halogen free photovoltaic wire sunlight resistant. Single conductor, flame retardant insulation.

Double insulated, electron-beam cross-linked, halogen free photovoltaic wire sunlight resistant. Single conductor, flame retardant insulation. Technical Data Sheet BETAflam Solar 125 flex UL 4703 Description Double insulated, electron-beam cross-linked, halogen free photovoltaic wire sunlight resistant. Single conductor, flame retardant insulation.

More information

CMZH Low Smoke 0-Halogen Flame- Retardant Mass Transit Tag

CMZH Low Smoke 0-Halogen Flame- Retardant Mass Transit Tag STANDARD COLOR CMZH Low Smoke 0-Halogen Flame- Retardant Mass Transit Tag TECHNICAL DATA SHEET Revision Number. 1 Last Edited 9. januar 2019 OTHER COLORS MATERIAL Flat band cross linked polyolefin. OPERATING

More information

Shipboard & Offshore Cables

Shipboard & Offshore Cables Shipboard & Offshore Cables Shipboard & Offshore Cables Páge Introduction 3 Power Cables XL / XL-FR 5 XC4L / XC4L-FR 6 XLC4L / XLC4L-FR 7 Instrumentation cables XHL / XHL-FR 8 XOL / XOL-FR 9 XHC4L / XHC4L-FR

More information

Total Fire Solutions. Includes BS 8519 and the updated BS :

Total Fire Solutions. Includes BS 8519 and the updated BS : Total Fire Solutions Includes BS 8519 and the updated BS 5266-1:2011 www.aeicables.co.uk Introduction: Total Fire Solutions Power and control cable systems for life safety and fire-fighting applications

More information

fire resistant cables

fire resistant cables Building Technology fire resistant cables Special electrical and optical cables www.tecnikabel.com Special electrical and optical cables 2 INTRODUCTION Structured cabling solutions. Tecnikabel can provide

More information

CABLES FOR ALARM AND SAFETY SYSTEMS

CABLES FOR ALARM AND SAFETY SYSTEMS CABLES FOR ALARM AND SAFETY SYSTEMS 2 IT S ALL ABOUT RELIABILITY. It is always important to choose high quality cables, especially when it comes to alarms and safety systems. Even small and seemingly insignificant

More information

INTRODUCTION. Our diverse range of world-class Specialty Insulated Wires and Cablesinclude: LV Cables -

INTRODUCTION. Our diverse range of world-class Specialty Insulated Wires and Cablesinclude: LV Cables - MARINE CABLES Your Power Partner on the Seas INTRODUCTION We, a member of the Al-Bahja Group of Companies, are an ISO:900:2008 BASEC, UK certified integrated quality producer of LV and MV Cables, Wires&

More information

Copper LAN cable. This specification describes the general requirements for AMP NETCONNECT* copper LAN cable.

Copper LAN cable. This specification describes the general requirements for AMP NETCONNECT* copper LAN cable. Product Specification 108-93018 25/Aug/2011 Rev H Copper LAN cable 1. SCOPE 1.1. Content This specification describes the general requirements for AMP NETCONNECT* copper LAN cable. 2. APPLICABLE DOCUMENTS

More information

OIL & GAS INDUSTRY OTHER INDUSTRIES

OIL & GAS INDUSTRY OTHER INDUSTRIES For ATEX Areas OIL & GAS INDUSTRY OTHER INDUSTRIES OIL & GAS INDUSTRY POTENTIALLY HAZARDOUS Class I GASES VAPORS LIQUIDS Petrosumsave Zone 0 An area in which an explosive mixture is continuously present,

More information

BS EN :2004. Test On Electric And Optical Fibre Cables Under Fire Conditions. WF Report Number. Date: 14 th November 2008.

BS EN :2004. Test On Electric And Optical Fibre Cables Under Fire Conditions. WF Report Number. Date: 14 th November 2008. BS EN 60332-1-2:2004 Test On Electric And Optical Fibre Cables Under Fire Conditions WF Report Number 177603 Date: 14 th November 2008 Test Sponsor: FTC Fabbrica Trentina Conduttori Srl 0249 Page 2 of

More information

DNVGL-CP-0402 Edition February 2016

DNVGL-CP-0402 Edition February 2016 CLASS PROGRAMME Type approval DNVGL-CP-0402 Edition February 2016 The electronic pdf version of this document, available free of charge from http://www.dnvgl.com, is the officially binding version. FOREWORD

More information

ZH Low Smoke 0-Halogen Flameretardant Identification Sleeves

ZH Low Smoke 0-Halogen Flameretardant Identification Sleeves STANDARD TUBE COLOR ZH Low Smoke 0-Halogen Flameretardant Identification Sleeves TECHNICAL DATA SHEET Revision Number. 1 Last Edited 24. juli 2018 The ZH-2X Heat Shrinkable Wire Markers are made of halogen

More information

Rolling Stock Cables.

Rolling Stock Cables. Rolling Stock Cables www.caledonian-cables.co.uk www.addison-cables.com & Addison, established in 1978, produced a wide range of copper and fiber optic cables for communication, power and electronics in

More information

IEC UNE DESIGN. 1. Conductor. 2. Insulation. Cross-linked polyethylene (XLPE) 3. Outer sheath. Flexible PVC, black colour.

IEC UNE DESIGN. 1. Conductor. 2. Insulation. Cross-linked polyethylene (XLPE) 3. Outer sheath. Flexible PVC, black colour. 67 POWERFLEX RV-K POWERFLEX RV-K Industrial flexible cable for power transmission. 1 IEC 60502-1 - UNE 21123-2 DESIGN 1. Conductor 2 Electrolytic copper, class 5 (flexible), based on EN 60228 and IEC 60228.

More information

Author Owner Issue Authority Name: Gordon MacKenzie Title: Senior Engineer Engineering Design and Standards

Author Owner Issue Authority Name: Gordon MacKenzie Title: Senior Engineer Engineering Design and Standards 1. SCOPE This Specification details requirements for General Wiring cables up to and including 450/750V for use on lighting and general power wiring installations complying with BS 7671 but not forming

More information

FIRE PERFORMANCE CABLE

FIRE PERFORMANCE CABLE FIRE PERFORMANCE CABLE Manufactured to BS 7629-1 Table 1 Plain Annealed Copper Conductors / Silicone Rubber Insulated / Double Layer of Aluminium/ Polyester Laminated Tapes / Circuit Protective Conductor

More information

Single core cables with reduced wall thickness

Single core cables with reduced wall thickness Product description: RADOX 4 GKW -AX 1800V M Nominal voltage: Hazard level: Single core cables with reduced wall thickness 1800 / 3000 V AC M (extra low temperature, extra oil and extra fuel resistant)

More information

CORFLEX. TYPE MC-HL & MV-105 or MC-HL OIL & GAS CABLES

CORFLEX. TYPE MC-HL & MV-105 or MC-HL OIL & GAS CABLES CORFLEX TYPE MC-HL & MV-105 or MC-HL OIL & GAS CABLES INDEX Instrumentation Cables - Pairs and Triads (0V*)... 2 - The Original MC-HL Technology In 1958 Canada Wire and Cable, which s now part of Nexans,

More information

Havells Fire Survival Cables

Havells Fire Survival Cables Fire Survival Cables Designed for Critical Installation of National Importance Airports / Thermal Power Plants Metro Rail Projects / Rail Terminals / Nuclear Interstate Bus Terminals / Installation Prone

More information

AFUMEX LSX LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS:

AFUMEX LSX LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS: PRODUCT DATASHEET & APPLICATIONS GUIDE LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 KEY BENEFITS: BASEC approved for the full size range of BS8436 (1.0mm 2 to 2.5mm 2 ) Additionally tested for

More information

AFUMEX LSX BASEC APPROVED LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS:

AFUMEX LSX BASEC APPROVED LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS: PRODUCT DATASHEET & APPLICATIONS GUIDE BASEC APPROVED LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 KEY BENEFITS: BASEC approved for the full size range of BS8436 (1.0mm 2 to 2.5mm 2 ) Additionally

More information

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red OFC-UT-CST Fire resistant Armoured Indoor/Outdoor steel tape armoured (CST) double LSHF-FR sheathed optical cable with 2 24 fibres. VDE: A/I-DQ(ZN)H(SR)H 3rd party verification of the fire tests by BUREAU

More information

UV RESISTANT ACCORDING TO HD 605 RULE

UV RESISTANT ACCORDING TO HD 605 RULE UV RESISTANT ACCORDING TO HD 605 RULE Faced with increasingly frequent requirements to install outdoor wiring for data and signals, we further developed a special range of cables called: BLUE TOP LINE

More information

CORFLEX TYPE MC-HL POWER, CONTROL & INSTRUMENTATION CABLES

CORFLEX TYPE MC-HL POWER, CONTROL & INSTRUMENTATION CABLES CORFLEX TYPE MC-HL POWER, CONTROL & INSTRUMENTATION CABLES CORFLEX TYPE MC-HL POWER, CONTROL & INSTRUMENTATION CABLES INDEX Corflex MC-HL Instrumentation - Pairs and Triads (0V*)... 1 - CORFLEX Cables

More information

OFFSHORE CABLES. Top Cable Central Headquarters. Leonardo Da Vinci, number Rubí (Barcelona) Spain

OFFSHORE CABLES.   Top Cable Central Headquarters. Leonardo Da Vinci, number Rubí (Barcelona) Spain Top Cable Central Headquarters Leonardo Da Vinci, number 1 08191 Rubí (Barcelona) Spain OFFSHORE CABLES Tel +4 9 586 21 78 +4 9 586 21 68 Fax +4 9 586 21 65 sales@topcableoffshoremarine.com http://www.topcableoffshoremarine.com

More information

ENHANCED FIRE PERFORMANCE CABLE

ENHANCED FIRE PERFORMANCE CABLE FIRE PERFORMANCE CABLE Manufactured to BS 7629-1 Table 1 Plain Annealed Copper Conductors / Silicone Rubber Insulated / Glass Fibre Tape / Tinned Copper Circuit Protective Conductor / Double Layer of Copper/Polyester

More information

System Circuit integrity in the event of fire. Safety cables and systems from a pro. Cabling Solutions

System Circuit integrity in the event of fire. Safety cables and systems from a pro. Cabling Solutions System Circuit integrity in the event of fire and systems from a pro Cabling Solutions Safety cable systems Halogen-free safety cables with reference to VDE H05Z-K, H07Z-K / U / R 22 NHXMH, (N)HXM(St)H

More information

THE INNOVATIVE CABLE PRODUCER INSTRUMENTATION CABLES FOR THE INDUSTRY - AND PLANT CONSTRUCTION

THE INNOVATIVE CABLE PRODUCER INSTRUMENTATION CABLES FOR THE INDUSTRY - AND PLANT CONSTRUCTION THE INNOVATIVE CABLE PRODUCER INSTRUMENTATION CABLES FOR THE INDUSTRY - AND PLANT CONSTRUCTION About Us 60 Countries Using Birtaş Cable Products As of 2014 Birtaş Kablo is exporting its products to 60

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Presley House Presley Way Crownhill Milton Keynes MK8 0ES United Kingdom Contact: Jeremy Hodge Tel: +44 (0) 1908 267300 Fax: +44 (0) 1908

More information

CIR CRUSH & IMPACT RESISTANT ARCTIC GRADE OIL & GAS CABLES

CIR CRUSH & IMPACT RESISTANT ARCTIC GRADE OIL & GAS CABLES CIR CRUSH & IMPACT RESISTANT ARCTIC GRADE OIL & GAS CABLES Gexol CIR ARCTIC GRADE (AG) Crush and Impact Resistant Without External Armoring Passes the same stringent crush and impact testing required by

More information

CIR AG Power Cables. CIR AG Control Cable. CIR Type VFD Cable. CIR AG Ratings & Approvals. n UL Listed as Type TC-ER n UL Listed as TC-ER-HL (E123629)

CIR AG Power Cables. CIR AG Control Cable. CIR Type VFD Cable. CIR AG Ratings & Approvals. n UL Listed as Type TC-ER n UL Listed as TC-ER-HL (E123629) Gexol CIR ARCTIC GRADE (AG) Crush and Impact Resistant Without External Armoring Passes the same stringent crush and impact testing required by UL 2225 for Type MC-HL n Shortest Lead Times Standard 8-10

More information

DNVGL-CP-0399 Edition March 2016

DNVGL-CP-0399 Edition March 2016 CLASS PROGRAMME Type approval DNVGL-CP-0399 Edition March 2016 The electronic pdf version of this document, available free of charge from http://www.dnvgl.com, is the officially binding version. FOREWORD

More information

CIR CRUSH & IMPACT RESISTANT OIL & GAS CABLES

CIR CRUSH & IMPACT RESISTANT OIL & GAS CABLES CIR CRUSH & IMPACT RESISTANT OIL & GAS CABLES Gexol CIR Crush and Impact Resistant Without External Armoring Passes the same stringent crush and impact testing required by UL 2225 for Type MC-HL Index

More information

Flexflame. Arctic Grade Cables for Extreme Conditions. Photo: Sakhalin Energy Investement Company Ltd.

Flexflame. Arctic Grade Cables for Extreme Conditions. Photo: Sakhalin Energy Investement Company Ltd. Flexflame Arctic Grade Cables for Extreme Conditions Photo: Sakhalin Energy Investement Company Ltd. Linking the future Draka Norsk Kabel is a part of Prysmian Group, a worldwide leader in the cable industry.

More information

CONTENTS. Introduction Customer Service BS codes of practice BS Fire Performance Cable Selection Guide... 7

CONTENTS. Introduction Customer Service BS codes of practice BS Fire Performance Cable Selection Guide... 7 CONTENTS Page Introduction... 1 Customer Service... 2 BS codes of practice BS 8519... 5 Fire Performance Cable Selection Guide... 7 FlamBICC Introduction...8 FlamBICC 1...10 FlamBICC 2...12 FlamBICC 3...14

More information

THE MYSORE UNIT OF RPG CABLES MANUFACTURES A RANGE OF INSTRUMENTATION CABLES

THE MYSORE UNIT OF RPG CABLES MANUFACTURES A RANGE OF INSTRUMENTATION CABLES THE MYSORE UNIT OF RPG CABLES MANUFACTURES A RANGE OF INSTRUMENTATION CABLES The Mysore Unit of RPG Cables is the largest and most diversified cables manufacturing facility in the South of India. The unit

More information

The Quality Connection. BETAflam safety cables for highest demands

The Quality Connection. BETAflam safety cables for highest demands The Quality Connection BETAflam safety cables for highest demands 2 For solutions that will still be standard tomorrow. BETAflam safety cables Thanks to their proven quality, BETAflam safety cables are

More information

Flame Retardant EP/CPE POWER, CONTROL & INSTRUMENTATION CABLES

Flame Retardant EP/CPE POWER, CONTROL & INSTRUMENTATION CABLES Flame Retardant EP/CPE POWER, CONTROL & INSTRUMENTATION CABLES 37-754 FLAME RETARDANT EP/CPE TYPE TC OR TC-ER POWER CABLE Two Five Conductor + Ground (Two, Three & Four Conductor) 600 V Rated 90 C Conductor*

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK ISO/IEC 17065:2012 to provide product conformity certification Presley Way Crownhill Milton Keynes MK8 0ES Contact: Tracie Hunter Tel: +44 (0)1908 267300 Fax: +44 (0)1908 267255 E-Mail: mail@basec.org.uk

More information

STANDARDS INSTALLATION. Certificate No 077m

STANDARDS INSTALLATION. Certificate No 077m Certificate No 077m > Prysmian FP600 is a unique enhanced performance fire resistant power cable, designed specifically to meet the more onerous fire survival requirements now requested by regulators and

More information

FIRE RESISTANT CABLES FP200 GOLD

FIRE RESISTANT CABLES FP200 GOLD FIRE RESISTANT CABLES FP200 GOLD FIRE RESISTANT CABLES FP200 GOLD BS7629-1 FP200 GOLD Clause 26.2 > The original highly durable and dressable, easy to terminate and install fire resistant cable. Approved

More information

BS FP600 achieves the maximum 120 minute rating under the BS test conditions, which is required for fire fighting applications.

BS FP600 achieves the maximum 120 minute rating under the BS test conditions, which is required for fire fighting applications. FIRE RESISTANT CABLES FP600 FIRE RESISTANT CABLES FP600 BS7346-6 FP600 > Prysmian FP600 is a unique enhanced performance fire resistant power cable, designed specifically to meet the more onerous fire

More information

GCRG. Multi Loose Tube Cables Universal Indoor / Outdoor A/I-DQ(ZN)BH Improved Rodent Protection v7.0. Ordering Information.

GCRG. Multi Loose Tube Cables Universal Indoor / Outdoor A/I-DQ(ZN)BH Improved Rodent Protection v7.0. Ordering Information. GCRG Multi Loose Tube Cables Universal Indoor / Outdoor A/I-DQ(ZN)BH Improved Rodent Protection 05-05-7 v7.0 Ordering Information Belden Part Numbers Fibre Description / count 4 8 8 4 30 36 6.5/5-OM GCRG04

More information

OUR SOLUTION: YOUR CABLE. PRODUCTION OVERVIEW

OUR SOLUTION: YOUR CABLE. PRODUCTION OVERVIEW OUR SOLUTION: YOUR CABLE. PRODUCTION OVERVIEW Our expertise Our expertise Company MUCKENHAUPT & NUSSELT is a cable production company in Wuppertal, which has been successful in the market since 1926 and,

More information

GUCN. Central Loose Tube Cables Universal Indoor / Outdoor - Corrugated Steel Tape Armor (CST) A/I-DQ(ZN)(SR)H Full Rodent Protection v13.

GUCN. Central Loose Tube Cables Universal Indoor / Outdoor - Corrugated Steel Tape Armor (CST) A/I-DQ(ZN)(SR)H Full Rodent Protection v13. GUCN Central Loose Tube Cables Universal Indoor / Outdoor - Corrugated Steel Tape Armor (CST) A/I-DQ(ZN)(SR)H Full Rodent Protection 07-07-05 v3.0 Ordering Information Belden Part Numbers Fibre Description

More information

The Quality Connection. Cable fire protection Flammability tests on ship and offshore cables

The Quality Connection. Cable fire protection Flammability tests on ship and offshore cables The Quality Connection Cable fire protection Flammability tests on ship and offshore cables Fire protection 2 Marine technologies product range The right cable for any application. Commercial shipbuilding

More information

Wire and Cable. For more information on these Tyco Electronics products, visit the following website:

Wire and Cable. For more information on these Tyco Electronics products, visit the following website: 26 Wire and Cable Raychem High Performance Wire and Cable....26-2 to 26-4 Madison Cable Products...................26-5 to 26-7 Reference the following cables in Section 15 of this catalog: Premises Networking

More information

Cablosam Tapes for Fire-Resistant Cables

Cablosam Tapes for Fire-Resistant Cables Cablosam Tapes for Fire-Resistant Cables 2 Cablosam Tapes for Fire-Resistant Cables We Enable Energy As one of the oldest industrial companies in Switzerland, founded in 1803, we focus on products and

More information

Braided Sleeving. Mechanical Protection Electrical Insulation Thermal and Fire Insulation Electromagnetic Shielding

Braided Sleeving. Mechanical Protection Electrical Insulation Thermal and Fire Insulation Electromagnetic Shielding 2017 Supplier of choice for Harness Components Aerospace Defence Energy Commercial Marine Motorsport Braided Sleeving Powerful Solutions for Protection Mechanical Protection Electrical Insulation Thermal

More information

Tratos Railway Cables

Tratos Railway Cables January 2013 Tratos Railway Cables Cables for a moving world www.tratos.eu Introduction Tratos Cavi is a company specialising in the production of power, signalling, control and telecommunications cables

More information

Energy Division Heat-shrinkable joints for halogen-free, flame-retardant and fire-resistand cables up to 1 kv

Energy Division   Heat-shrinkable joints for halogen-free, flame-retardant and fire-resistand cables up to 1 kv Energy Division http://energy.tycoelectronics.com Heat-shrinkable joints for halogen-free, flame-retardant and fire-resistand cables up to 1 kv R Heat-shrinkable joints for halogen-free, flame-retardant

More information

Sensor and transducer cables

Sensor and transducer cables Sensor and transducer cables Special cables for industrial instrumentation Expertise in sensor cables Nexans has a great expertise in research and development of special and customized sensor cables for

More information

SHIELD TYPE MULTICONDUCTOR MULTIPAIR

SHIELD TYPE MULTICONDUCTOR MULTIPAIR CABLE FINDER GUIDE CONDUCTOR SIZE 18 AWG METRIC 0,97mm 2 SHIELD TYPE MULTICONDUCTOR MULTIPAIR Materials Ratings No. of Alpha Page No. of Alpha Page Cable Type Insulation Jacket Temp. Voltage Conductors

More information

FIRE RESISTANT CABLES FP400

FIRE RESISTANT CABLES FP400 FIRE RESISTANT CABLES FP400 FIRE RESISTANT CABLES FP400 BS7846-F2 CABLE CHARACTERISTICS FP400 APPROVALS INSTALLATION Certificate No 077b Certificate No 517b > Prysmian FP400 is the original fire resistant

More information

PHOTOVOLTAIC CABLES. Photovoltaic Cable 2000V/1500V Photovoltaic Cable 2000V/1000V

PHOTOVOLTAIC CABLES. Photovoltaic Cable 2000V/1500V Photovoltaic Cable 2000V/1000V PHOTOVOLTAIC CABLES PHOTOVOLTAIC CABLES INDEX n AmerSol Dual-Certified (UL / ETL) Photovoltaic Cable 2000V/1500V....................... 2-3 n AmerSol Dual-Certified (UL / ETL) Photovoltaic Cable 2000V/1000V.......................

More information

Evolution of Cable Fire Safety Standards in Australia

Evolution of Cable Fire Safety Standards in Australia Evolution of Cable Fire Safety Standards in Australia INTRODUCTION Fire safety standards for electrical cables have evolved over the past few decades to the extent that they are now well established along

More information

Flexible Power Cable DLO

Flexible Power Cable DLO 37-119 Flexible Power Cable DLO 2000 Volts 90 C Diesel Locomotive Cable Limited Smoke (Sizes 2/0 and higher) EP/CPE RHH, RHW-2 Flexible-stranded, tin-coated annealed copper Flame retardant, oil and sunlight

More information

Data sheet OpDAT breakout cable 12x1 OM4 - bend insensitive, class Dca s1 d1 a1

Data sheet OpDAT breakout cable 12x1 OM4 - bend insensitive, class Dca s1 d1 a1 Page 1/9 Illustrations Principle diagram See enlarged drawings at the end of document Product specification connection cable I-V(ZN)HH breakout cable for direct connector termination for indoors and outdoors

More information

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red Indoor/Outdoor steel tape armoured (CST) double LSHF-FR sheathed optical cable with 2 24 fibres. VDE: A/I-DQ(ZN)H(SR)H 3rd party verification of the fire tests by BUREAU VERITAS December 2014 OFC-UT-CST

More information

DNVGL-CP-0401 Edition February 2016

DNVGL-CP-0401 Edition February 2016 CLASS PROGRAMME Type approval DNVGL-CP-0401 Edition February 2016 The electronic pdf version of this document, available free of charge from http://www.dnvgl.com, is the officially binding version. FOREWORD

More information

MEDIUM VOLTAGE CABLES INSTRUMENTATION CABLES RUBBER CABLES FIRE RESISTANT CABLES

MEDIUM VOLTAGE CABLES INSTRUMENTATION CABLES RUBBER CABLES FIRE RESISTANT CABLES RUBBER CABLES FIRE RESISTANT CABLES INSTRUMENTATION CABLES MEDIUM VOLTAGE CABLES Halley Cables, established in 2006, is a dynamic company, specialized in power supply, which focuses on customers satisfaction.

More information

Fire Resistant Cables

Fire Resistant Cables Fire Resistant Cables Ducab (Abu Dhabi) Factory P.O. Box 9171, Abu Dhabi, UAE Tel: (971-2) 502 7777 Fax: (971-2) 502 7888 email: ducab@ducab.com Ducab Connect P.O. Box 11529, Dubai, United Arab Emirates

More information

FIRE RESISTANT CABLES FP300

FIRE RESISTANT CABLES FP300 FIRE RESISTANT CABLES FP300 Fire resistant LSOH power cables for fixed wiring FIRE RESISTANT CABLES FP300 LPCB Ref No: 077e/01 FP300 > Prysmian FP300 is designed for cabling essential safety circuits associated

More information