1 Power Cables
2 Power Cables Page Introduction 3 RV 4 RVMV 5 RVSV 6 RVFV 7 ELECWIRES 2
3 INTRODUCTION Power Cables Power cables for electrical installations, domestic & industrial, specifically designed for supplies with a 0.6/1 kv voltage service range in energy & control applications. The most commonly used configurations are: RV. Unarmoured Cables RVMV. Steel Wire ed Cables RVSV. Corrugated Steel Tape ed Cables RVFV. Steel Tape ed Cables According to cable behaviour against fire, the above mentioned configurations can be manufactured: Fire resistant. IEC 60331, UNE-EN y UNE-EN Fire retardant. IEC Cat. C (UNE-EN Cat. C) Flame retardant. IEC (UNE-EN ) Low Smoke Emission. IEC (UNE-EN ) Halogen free. IEC y UNE-EN OPTIONS & ALTERNATIVES Different types of cable features can be provided: Hydrocarbon and mineral oil resistant. UNE-EN & UIC 895 OR Configurations with different types of armours and materials ELECWIRES 3
4 POWER CABLES RV 0,6/1 KV CONSTRUCTIÓN: Conductors Annealed or tinned electrolytic copper. Classes: 1, 2 y 5 Sections: from 0,5 to 400 mm 2. *OPTION, aluminium. *OPTION, composition acc. to AWG (American Wire Gauge). XLPE (Cross linked Polyethylene). *OPTION, EPR (Ethylene Propylene), PVC (Polyvinyl Chloride) y otros. Assembly Cabled in concentric layers. Outer Sheath *OPTION, Hydrocarbon and mineral oil resistant plastic compounds and LSZH thermoplastic (Low Smoke Zero Halogen). APPLICATION & PROPERTIES: Power cables for power supply connections, electrical substations, distribution networks, lightning networks and civil & industrial installations in general. Suitable for outdoor and indoor services, they can be installed in ducts, trays or conduits. STANDARDS: Construction UNE-EN Flame retardant UNE-EN IEC *OPTIONS (others available under request) Conductor Sheaths Tinned copper and aluminium Materials Fire resistant Mineral oil & HC resistant ELECWIRES 4
5 POWER CABLES RVMV 0,6/1 KV CONSTRUCTIÓN: Conductors Annealed or tinned electrolytic copper. Classes: 1, 2 & 5 Sections: from 0,5 to 400 mm 2. *OPTION, aluminium. *OPCION, composition acc. To AWG (American Wire Gauge). XLPE (Cross linked Polyethylene). *OPTION, EPR (Ethylene Popylene), PVC (Policloruro de Vinilo) and others. Assembly Cabled in concentric layers. Inner Sheath Galvanized steel wires. *OPTION, aluminium wires. Outer Sheath resistant plastic compounds and LSZH thermoplastic (Low Smoke Zero Halogen). APPLICATION Y PROPERTIES: Power cables for power supply connections, electrical substations, distribution networks, lightning networks and civil & industrial installations in general. The steel armour provides very high mechanical and anti rodent protection. Suitable for outdoor and indoor services, they can be installed in ducts, trays, aerial or direct burial. STANDARDS: Construction UNE-EN Flame retardant UNE-EN IEC *OPTIONS (others available under request) Conductor Sheaths Tinned copper and aluminium Materials Fire resistant Mineral oil & HC resistant Aluminium wires ELECWIRES 5
6 POWER CABLES RVSV 0,6/1 KV CONSTRUCTIÓN: Conductors Annealed or tinned electrolytic copper. Classes: 1, 2 & 5 Sections: from 0.5 to 400 mm 2. *OPTION, aluminium. *OPTION, composition acc. to AWG (American Wire Gauge). XLPE (Cross linked Polyethylene). *OPTION, EPR (Ethylene Propylene), PVC (Polyvinyl Chloride) and others. Assembly Cabled in concentric layers. Inner Sheath Steel corrugated tape. Thickness: from 0.15 to 0.50 mm. *OPTION, Aluminium corrugated tape. Outer Sheath APPLICATION Y PROPERTIES: Power cables for power supply connections, electrical substations, distribution networks, lightning networks and civil & industrial installations in general. The armour provides very high mechanical and anti rodent protection. Suitable for outdoor and indoor services, they can be installed in ducts, trays, aerial or direct burial. STANDARDS: Construction UNE-EN Flame retardant UNE-EN IEC *OPTIONS (others available under request) Conductor Sheaths Tinned copper and aluminium Materials Fire resistant Mineral oil & HC resistant Aluminium corrugated tape ELECWIRES 6
7 POWER CABLES RVFV 0,6/1 KV CONSTRUCTION: Conductors Annealed or tinned electrolytic copper. Classes: 1, 2 & 5 Sections: from 0.5 to 400 mm 2. *OPTION, aluminium. *OPTION, composition acc. to AWG (American Wire Gauge). XLPE (Cross linked Polyethylene). *OPTION, EPR (Ethylene Propylene), PVC (Polyvinyl Chloride) and others. Assembly Cabled in concentric layers. Inner Sheath Steel tape helicoidally placed. Thickness: from 0.15 to 0.50 mm. *OPTION, aluminium tape helicoidally placed. Outer Sheath APLICATION & PROPERTIES: Power cables for power supply connections, electrical substations, distribution networks, lightning networks and civil & industrial installations in general. The armour of steel tape helicoidally placed provides very high mechanical and anti rodent protection with high flexibility. Suitable for outdoor and indoor services, they can be installed in ducts, trays, aerial or direct burial. STANDARDS: Construction UNE-EN Flame retardant UNE-EN IEC *OPTIONS (others available under request) Conductor Sheaths Tinned copper and aluminium Materials Fire resistant Mineral oil & HC resistant Aluminium tape helicoidally placed ELECWIRES 7
8 C/ Olmo Polígono Industrial Malpica-Alfindén La Puebla de Alfindén Zaragoza España-Spain Tel: info@elecwires.es ELECWIRES 8
Catalogue Power Cables
Catalogue Power Cables Conductores Tecnológicos S.A. www.contecsa.es Index of Cables Page Introduction 13 RV 14 RVMV 15 RVSV 16 RVFV 17 Conductores Tecnológicos S.A. 2 www.contecsa.es INTRODUCTION Power
More informationTelecommunication Cables
Telecommunication Cables Telecommunication Cables Introduction 3 EAP / EAP-R 4 EAPSP / EAPSP-R 5 ISP / ICP 6 Page ELECWIRES 2 www.elecwires.es INTRODUCCIÓN Telecommunication Cables Telephone cables suitable
More informationCatalogue. Instrumentation & Control Cables
Catalogue Instrumentation & Control Cables Conductores Tecnológicos S.A. www.contecsa.es Index of Cables Page Introduction 3 Instrumentation VOV 4 VHOV 5 VOVMV 6 VHOVMV 7 Control RV 8 RZ1C3Z1 9 Conductores
More informationShipboard & Offshore Cables
Shipboard & Offshore Cables Shipboard & Offshore Cables Páge Introduction 3 Power Cables XL / XL-FR 5 XC4L / XC4L-FR 6 XLC4L / XLC4L-FR 7 Instrumentation cables XHL / XHL-FR 8 XOL / XOL-FR 9 XHC4L / XHC4L-FR
More informationCatalogue Telecommunication Cables INTRODUCCIÓN
Catalogue Telecommunication Cables INTRODUCCIÓN Conductores Tecnológicos S.A. www.contecsa.es Index of Cables Page Introduction 3 EAP / EAP-R 4 EAPSP / EAPSP-R 5 ISP / ICP 6 Conductores Tecnológicos S.A.
More information600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (Multicore)
600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (Multicore) FGD400 1RV-R (CU/XLPE/PVC 600/1000V Class ) FGD400 1RVMV-R (CU/XLPE/PVC/SWA/PVC 600/1000V Class ) PVC Outer Sheath Plain Annealed
More informationBS /1000V XLPE Insulation LSZH Sheath Cables
BS 8573 600/1000V XLPE Insulation LSZH Sheath Cables Caledonian www.addison-cables.com Company Profile Caledonian & Addison, branded under Caledoniea & Addimax, established in 1978, offers one of the most
More information600/1000V XLPE Insulated, LSZH Sheathed, Double steel tape Armoured Power Cables (3 Cores)
Caledonian Flame Retardant Power & Control Cables www.caledonian-s.co.uk www.addison-s.com 600/1000V XLPE Insulated, LSZH Sheathed, Double steel tape Armoured Power Cables (3 Cores) FTX400 1RZ1MZ1-R (CU/XLPE/LSZH/DSTA/LSZH
More informationSchedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK
ISO/IEC 17065:2012 to provide product conformity certification Presley Way Crownhill Milton Keynes MK8 0ES Contact: Tracie Hunter Tel: +44 (0)1908 267300 Fax: +44 (0)1908 267255 E-Mail: mail@basec.org.uk
More informationTratos Railway Cables
January 2013 Tratos Railway Cables Cables for a moving world www.tratos.eu Introduction Tratos Cavi is a company specialising in the production of power, signalling, control and telecommunications cables
More informationFlame Retardant Overall Screened Instrumentation Cables (multicore)
Flame Retardant Overall Screened Instrumentation Cables (multicore) RE-2X(St)H RE-2X(St)HSWAH LSZH Outer Sheath Tinned Copper Drain Wire LSZH Inner Sheath XLPE Insulation Plain Annealed Copper Aluminium/polyester
More informationPHOTOVOLTAIC CABLES. Photovoltaic Cable 2000V/1500V Photovoltaic Cable 2000V/1000V
PHOTOVOLTAIC CABLES PHOTOVOLTAIC CABLES INDEX n AmerSol Dual-Certified (UL / ETL) Photovoltaic Cable 2000V/1500V....................... 2-3 n AmerSol Dual-Certified (UL / ETL) Photovoltaic Cable 2000V/1000V.......................
More informationOIL & GAS INDUSTRY OTHER INDUSTRIES
For ATEX Areas OIL & GAS INDUSTRY OTHER INDUSTRIES OIL & GAS INDUSTRY POTENTIALLY HAZARDOUS Class I GASES VAPORS LIQUIDS Petrosumsave Zone 0 An area in which an explosive mixture is continuously present,
More informationIEC UNE DESIGN. 1. Conductor. 2. Insulation. Cross-linked polyethylene (XLPE) 3. Outer sheath. Flexible PVC, black colour.
67 POWERFLEX RV-K POWERFLEX RV-K Industrial flexible cable for power transmission. 1 IEC 60502-1 - UNE 21123-2 DESIGN 1. Conductor 2 Electrolytic copper, class 5 (flexible), based on EN 60228 and IEC 60228.
More informationNote: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design.
ADDISON Flame Retardant RG59 B/U Coaxial cables Plain copper wire braid PE Solid Bare Copper PVC Outer Sheath APPLICATION The cables are designed for CCTV, security, smoke detection and evacuation monitoring
More informationFIRE RESISTANT CABLES
Conducting Value The Last Cable Standing FIRE RESISTANT CABLES 100/7b ISO 9001:2008 Certificate No. CS1-249 MANAGEMENT SYSTEMS Assessed to ISO 9001:2008 Cert/LPCB ref. 217 GOST ISO 9001-2011 (ISO 9001:2008)
More informationPRODUCT CATALOGUE Norröna
PRODUCT CATALOGUE Norröna WWW.SCANKAB.COM Table of contents MARINE AND OFFSHORE CABLES 1 TOXFREE XZ1-K (AS) - 0.6/1 kv 1 TOXFREE MARINE XO2TCuZ1-K (AS) - 150/250 V 5 4x2xAWG 24/1 CAT6 S/FTP LSZH-SHF1 -
More informationCaledonian Flame Retardant Coaxial Cables
Caledonian Flame Retardant Coaxial Cables www.caledonian-cables.co.uk www.addison-cables.com Flame Retardant RG59 Coaxial cables LSZH Outer Sheath Tinned Copper Braid Aluminium+polyester/Aluminium Tape
More informationFlame Retardant EP/CPE POWER, CONTROL & INSTRUMENTATION CABLES
Flame Retardant EP/CPE POWER, CONTROL & INSTRUMENTATION CABLES 37-754 FLAME RETARDANT EP/CPE TYPE TC OR TC-ER POWER CABLE Two Five Conductor + Ground (Two, Three & Four Conductor) 600 V Rated 90 C Conductor*
More informationHavells Fire Survival Cables
Fire Survival Cables Designed for Critical Installation of National Importance Airports / Thermal Power Plants Metro Rail Projects / Rail Terminals / Nuclear Interstate Bus Terminals / Installation Prone
More informationIEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission
ADDISON Flame Retardant CAT5e Data Cables FTX-CAT5e U/UTP4P24 FTX-CAT5e f/utp4p24 FTX-CAT5e sf/utp4p24 LSZH Outer Aluminium/Polyester Tape Solid Copper Conductor PE Insulation Tinned Copper Drain Wire
More informationAuthor Owner Issue Authority Name: Gordon MacKenzie Title: Senior Engineer Engineering Design and Standards
1. SCOPE This Specification details requirements for General Wiring cables up to and including 450/750V for use on lighting and general power wiring installations complying with BS 7671 but not forming
More informationFlexible Power Cable DLO
37-119 Flexible Power Cable DLO 2000 Volts 90 C Diesel Locomotive Cable Limited Smoke (Sizes 2/0 and higher) EP/CPE RHH, RHW-2 Flexible-stranded, tin-coated annealed copper Flame retardant, oil and sunlight
More informationHigh Performance LSZH Fire Resistant Cable
High Performance LSZH Fire Resistant Cable www.cavicel.com 104/2 FIRECEL SR 114H is the long and well established CAVICEL fire resistant cable in the market, since many years. These cables are third party
More informationTotal Fire Solutions. Includes BS 8519 and the updated BS :
Total Fire Solutions Includes BS 8519 and the updated BS 5266-1:2011 www.aeicables.co.uk Introduction: Total Fire Solutions Power and control cable systems for life safety and fire-fighting applications
More information600/1000V SR Insulated Flexibles Control Cables (2-4 Cores & Multicores)
600/1000V SR Insulated Flexibles Control Cables (2-4 Cores & Multicores) FFX400 1SZ1-R(PH60)(CU/SR/LSZH 600/1000V Class 2) FFX400 1SZ1-F(PH60)(CU/SR/LSZH 600/1000V Class 5) Silicone Rubber Insulation Plain
More informationCaledonian Fire resistant Coaxial Cables
Caledonian Fire resistant Coaxial Cables www.caledonian-cables.net www.addison-cables.com Fire resistant rg59 b/u Coaxial Cables RG59 B/U FR LSZH Sheath Fire Resistant Tape Copper Clad Steel/Bare Copper
More informationCORFLEX TYPE MC-HL POWER, CONTROL & INSTRUMENTATION CABLES
CORFLEX TYPE MC-HL POWER, CONTROL & INSTRUMENTATION CABLES CORFLEX TYPE MC-HL POWER, CONTROL & INSTRUMENTATION CABLES INDEX Corflex MC-HL Instrumentation - Pairs and Triads (0V*)... 1 - CORFLEX Cables
More informationCORFLEX. TYPE MC-HL & MV-105 or MC-HL OIL & GAS CABLES
CORFLEX TYPE MC-HL & MV-105 or MC-HL OIL & GAS CABLES INDEX Instrumentation Cables - Pairs and Triads (0V*)... 2 - The Original MC-HL Technology In 1958 Canada Wire and Cable, which s now part of Nexans,
More informationTHE INNOVATIVE CABLE PRODUCER INSTRUMENTATION CABLES FOR THE INDUSTRY - AND PLANT CONSTRUCTION
THE INNOVATIVE CABLE PRODUCER INSTRUMENTATION CABLES FOR THE INDUSTRY - AND PLANT CONSTRUCTION About Us 60 Countries Using Birtaş Cable Products As of 2014 Birtaş Kablo is exporting its products to 60
More informationIEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission
Flame Retardant RS485 Databus Cables Copper Wire Braid(optional) Individual AL/Polyester Tape(optional) Foam PE/Foam skin PE. Stranded Tinned Copper AL/Polyester Tape With Tinned Copper Drain Wire LSZH
More informationMulti-Core Fire Resistant Cable
Fire Resistant Cables / Multi-Core Fire Resistant Cable Approved to UL 444, Zeta ZFP series cables have received UL approval for standard applications. Standards Alarm Cable Z UL 444 Approval CMH Rated
More informationA Look at General Cable s GenFree II Product Line
L O W - S M O K E, Z E R O - H A L O G E N C A B L E S : B R I D G I N G T H E P E R F O R M A N C E G A P Next Generation Low-Smoke, Zero-Halogen (LSZH) Thermoset Insulation A Look at General Cable s
More informationAFUMEX LSX LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS:
PRODUCT DATASHEET & APPLICATIONS GUIDE LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 KEY BENEFITS: BASEC approved for the full size range of BS8436 (1.0mm 2 to 2.5mm 2 ) Additionally tested for
More informationCONNECTION SYSTEMS TRANSIT APPLICATIONS
CNNECTIN SYSTEMS TRANSIT APPLICATINS Ensure electrical and mechanical reliability with the engineered products and solutions of Shawcor s Connection Systems group INTEGRITY IS BEHIND EVERYTHING WE D. By
More informationINTRODUCTION. Our diverse range of world-class Specialty Insulated Wires and Cablesinclude: LV Cables -
MARINE CABLES Your Power Partner on the Seas INTRODUCTION We, a member of the Al-Bahja Group of Companies, are an ISO:900:2008 BASEC, UK certified integrated quality producer of LV and MV Cables, Wires&
More informationAFUMEX LSX BASEC APPROVED LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS:
PRODUCT DATASHEET & APPLICATIONS GUIDE BASEC APPROVED LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 KEY BENEFITS: BASEC approved for the full size range of BS8436 (1.0mm 2 to 2.5mm 2 ) Additionally
More informationFlexflame. Arctic Grade Cables for Extreme Conditions. Photo: Sakhalin Energy Investement Company Ltd.
Flexflame Arctic Grade Cables for Extreme Conditions Photo: Sakhalin Energy Investement Company Ltd. Linking the future Draka Norsk Kabel is a part of Prysmian Group, a worldwide leader in the cable industry.
More informationPower Control Cable Iec
POWER CONTROL CABLE IEC 60502 1 PDF - Are you looking for power control cable iec 60502 1 Books? Now, you will be happy that at this time power control cable iec 60502 1 PDF is available at our online
More informationSOLAR CABLES. Electric cables for solar PV installations
SOLAR CABLES Electric cables for solar PV installations TOP CABLE Top Cable is an internationally recognized manufacturer of electric cables, and is highly thought of by professional Engineers & Electricians
More informationTitle: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards
Change History Date Description of Change Pages / Sections Modified Change Approver Initials 8/1/17 Updated section on Manufacturers 3 1. 6/15/16 Updated division section from 16120 to 26 05 00, - mgl44
More informationAFIREFENIX SZ1-K 0,6/1 kv PH120 (AS+)
Page 1 / 7 Construction and tests. Standards: UNE 211025 Compliance with the Low Voltage Directive (LVD): 2014/35 / EU Construction Products Regulation (CPR) - Regulation (EU) Nº 305/2011: Reaction to
More informationMEDIUM, LOW AND CONTROL VOLTAGE CABLES
Related Sections U-M Design Guideline Sections: 260800 - Electrical Acceptance Tests Products Medium Voltage Primary Cables Primary power distribution cable shall be single conductor stranded copper, with
More informationTable of Contents. TELE-FONIKA KABLE SA (DMCC Branch). 4 TELE-FONIKA Kable Group 6 FLAME-X 950 SERIES 1 11 FLAME-X 950 SERIES 2
FLAME-X 950 TELE-FONIKA KABLE SA (DMCC Branch). Table of Contents is the Regional Middle East Sales Office of Tele-Fonika Kable S.A. from Poland, 4-th largest manufacturer of electric cables and wires
More informationDouble insulated, electron-beam cross-linked, halogen free photovoltaic wire sunlight resistant. Single conductor, flame retardant insulation.
Technical Data Sheet BETAflam Solar 125 flex UL 4703 Description Double insulated, electron-beam cross-linked, halogen free photovoltaic wire sunlight resistant. Single conductor, flame retardant insulation.
More informationEvolution of Cable Fire Safety Standards in Australia
Evolution of Cable Fire Safety Standards in Australia INTRODUCTION Fire safety standards for electrical cables have evolved over the past few decades to the extent that they are now well established along
More informationfire resistant cables
Building Technology fire resistant cables Special electrical and optical cables www.tecnikabel.com Special electrical and optical cables 2 INTRODUCTION Structured cabling solutions. Tecnikabel can provide
More informationLow Smoke Zero Halogen
Low Smoke Zero Halogen Cable for Marine Applications 621 Time Saver Avenue Harahan, LA 70123 Call Toll Free: (888) 326-5174 Email: marine@summit.com Marine Division summit.com/marine Power and Control
More informationCompact Module. Category 6A FTP Cabling System 1.1
Updated 24/09/12 Compact Module Cat 6A performance Suitable for 10-Gigabit Ethernet Ultra-slimline design Euro style module Interchangeable with other Euro Modules and blanks Individually QA tested Easy
More informationSAS Security and Alarm Safety Cables
CABLES Security and Alarm Safety Cables Security and Alarm Safety Cables LOW SMOKE ZERO HALOGEN The right range of cables for modern building installations e-catalogue 203/4 Flexible solutions for commercial,
More informationFIRE RESISTANT CABLES FP300
FIRE RESISTANT CABLES FP300 Fire resistant LSOH power cables for fixed wiring FIRE RESISTANT CABLES FP300 LPCB Ref No: 077e/01 FP300 > Prysmian FP300 is designed for cabling essential safety circuits associated
More informationCLEARING MISCONCEPTIONS ABOUT LOW-SMOKE, HALOGEN-FREE CABLES
CLEARING MISCONCEPTIONS ABOUT LOW-SMOKE, HALOGEN-FREE CABLES EXECUTIVE SUMMARY The use of low-smoke, halogen-free (LSHF) cables in commercial and residential building projects can help reduce equipment
More informationCable technology for highest safety requirements
Cable technology for highest safety requirements Daetwyler We are a provider of high-grade quality system solutions and services in the areas of structured data cabling, telecom carriers, safety cabling,
More informationLV FIRE RESISTANT CABLES
LV FIRE RESISTANT CABLES CONTENTS 3 GENERAL INTRODUCTION LV FIRE RESISTANT CABLES TECHNICAL INFORMATION 4 9 12 24 26 GENERAL CABLE STRUCTURE ELECTRICAL CHARACTERISTICS CURRENT RATING VOLTAGE DROP SHORT
More informationTHE TRUE FIRE SURVIVAL CABLE
25 YEAR THE TRUE FIRE SURVIVAL CABLE WARRANTY In 1989 we developed a unique process of manufacturing continuous mineral insulated copper cables. THE TRUE FIRE SURVIVAL CABLE We are the only UK manufacturer
More informationINSTRUCTION DE IS 23 SÉCURITÉ Rev. 2 SAFETY INSTRUCTION
1 INSTRUCTION DE IS 23 SÉCURITÉ Rev. 2 SAFETY INSTRUCTION Issued by : TIS/CFM Date of issue:1984 1st revision:1987 Technical Author: 2nd revision:1992/93 Materials and Cable Working Group Original:English
More informationMEDIUM VOLTAGE CABLES INSTRUMENTATION CABLES RUBBER CABLES FIRE RESISTANT CABLES
RUBBER CABLES FIRE RESISTANT CABLES INSTRUMENTATION CABLES MEDIUM VOLTAGE CABLES Halley Cables, established in 2006, is a dynamic company, specialized in power supply, which focuses on customers satisfaction.
More informationThe Quality Connection. BETAflam Fire Resistant Safety Cables
The Quality Connection BETAflam Fire Resistant Safety Cables BETAflam Contact Your personal customer number To offer you a more efficient service, we kindly ask you to mention your personal customer number
More informationOFFSHORE CABLES. Top Cable Central Headquarters. Leonardo Da Vinci, number Rubí (Barcelona) Spain
Top Cable Central Headquarters Leonardo Da Vinci, number 1 08191 Rubí (Barcelona) Spain OFFSHORE CABLES Tel +4 9 586 21 78 +4 9 586 21 68 Fax +4 9 586 21 65 sales@topcableoffshoremarine.com http://www.topcableoffshoremarine.com
More informationGAS FLOODING SYSTEM FOR CIFF AT BASEMENT
CONSTRUCTION OF BUILDINGS FOR LABORATORIES AND ASSOCIATED FACILITIES INSTEM BANGALORE SCHEDULE OF QUANTITIES FOR (EQUIPMENT ROOM 3 & 4) Sl.No. Description Unit Quantity Rate (in INR) in figure HFC-227ea
More informationWires, Cables, Cords and Adhesive Tapes
702-CRC-006-E Revision: 08 Page: 1/34 Elaborated by: Douglas Ferreira Checked by: Nelson A. Coelho Approved by: Arnaldo Barbulio Filho Approval date: 23\08\13 1 OBJECTIVE This document presents the complementary
More informationNuclear Power Plant LSZH Cable Overview
Nuclear Power Plant LSZH Cable Overview While still dominant, wire and cable usage of halogenated compounds in wire and cable, particularly PVC, has decreased over the past several years. Low-smoke, zero
More informationSTANDARDS INSTALLATION. Certificate No 077m
Certificate No 077m > Prysmian FP600 is a unique enhanced performance fire resistant power cable, designed specifically to meet the more onerous fire survival requirements now requested by regulators and
More informationCONTENTS. Introduction Customer Service BS codes of practice BS Fire Performance Cable Selection Guide... 7
CONTENTS Page Introduction... 1 Customer Service... 2 BS codes of practice BS 8519... 5 Fire Performance Cable Selection Guide... 7 FlamBICC Introduction...8 FlamBICC 1...10 FlamBICC 2...12 FlamBICC 3...14
More informationCore identification code. J-YY...BD Indoor Cable. J-YY...BD Indoor Cable. VDE 0815 Mutual capacitance. J-YY...BD Indoor Cable. Cu conductor 0.
Indoor cables J-YY...BD Indoor J-Y(ST)Y..LG Indoor Comparable products UNITRONIC J-2Y(ST)Y...ST III BD see page 271 Indoor telephone cables transmit analogue or digital signals In news and communication
More informationIntroduction.
Introduction The safety of occupants and users of public, commercial and industrial premises is of paramount importance. One important safety feature is the appropriate use of fire performance cables for
More informationENHANCED FIRE PERFORMANCE CABLE
FIRE PERFORMANCE CABLE Manufactured to BS 7629-1 Table 1 Plain Annealed Copper Conductors / Silicone Rubber Insulated / Glass Fibre Tape / Tinned Copper Circuit Protective Conductor / Double Layer of Copper/Polyester
More informationBS FP600 achieves the maximum 120 minute rating under the BS test conditions, which is required for fire fighting applications.
FIRE RESISTANT CABLES FP600 FIRE RESISTANT CABLES FP600 BS7346-6 FP600 > Prysmian FP600 is a unique enhanced performance fire resistant power cable, designed specifically to meet the more onerous fire
More informationSECTION ELECTRICAL GENERAL PROVISIONS
PART 1 GENERAL 1.01 SECTION INCLUDES A. General provisions for Electrical Systems B. Wire and cable for 600 volts and less. C. Wiring connectors. D. Electrical tape. E. Heat shrink tubing. F. Wire pulling
More informationINTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 61138 Second edition 1994-04 Cables for portable earthing and short-circuiting equipment This English-language version is derived from the original bilingual publication by leaving
More informationCaledonian fire Resistant signal & Data cables
fire Resistant signal & Data cables www.addison-tech.com fire Resistant Rs485 Databus cables Copper Wire Braid(optional) Individual AL/Polyester Tape(optional) Mica Glass Tape+PE/PE+Silicone Rubber Insulation
More informationPhotovoltaic Cables EN H1Z2Z2-K
Photovoltaic Cables EN 50618 H1Z2Z2-K COMPANY PROFILE Caledonian, established in 1978, offers one of the most complete lines of fiber and copper cabling system solutions with over hundreds of different
More informationFire Resistant Cables
Fire Resistant Cables Ducab (Abu Dhabi) Factory P.O. Box 9171, Abu Dhabi, UAE Tel: (971-2) 502 7777 Fax: (971-2) 502 7888 email: ducab@ducab.com Ducab Connect P.O. Box 11529, Dubai, United Arab Emirates
More informationFirecel Safety Cables
103/7 Firecel Safety Cables Low Smoke - Zero Halogen www.cavicel.com Firecel Safety Cables Low Smoke - Zero Halogen Over the last 30 years CAVICEL has developped a deep experience in studying, designing
More informationBS EN :2004. Test On Electric And Optical Fibre Cables Under Fire Conditions. WF Report Number. Date: 14 th November 2008.
BS EN 60332-1-2:2004 Test On Electric And Optical Fibre Cables Under Fire Conditions WF Report Number 177603 Date: 14 th November 2008 Test Sponsor: FTC Fabbrica Trentina Conduttori Srl 0249 Page 2 of
More informationQUALITY THROUGH EXPERIENCE
QUALITY THROUGH EXPERIENCE Brief History of ÜNTEL Established in 1972 Partnership of Ünlü and Günan families since then 40 years of manufacturing experience with an extensive production range for various
More informationFIRE RESISTANT CABLES FP400
FIRE RESISTANT CABLES FP400 FIRE RESISTANT CABLES FP400 BS7846-F2 CABLE CHARACTERISTICS FP400 APPROVALS INSTALLATION Certificate No 077b Certificate No 517b > Prysmian FP400 is the original fire resistant
More informationDNVGL-CP-0399 Edition March 2016
CLASS PROGRAMME Type approval DNVGL-CP-0399 Edition March 2016 The electronic pdf version of this document, available free of charge from http://www.dnvgl.com, is the officially binding version. FOREWORD
More informationCaledonian. FIREFLIX ire Resistant Coaxial Cables
Caledonian FIREFLIX ire Resistant Coaxial Cables table OF COntents Fire resistant Coaxial Cables Fire Resistant RG59 B/U coaxial cables...25 Fire Resistant RG6 A/U coaxial cables...28 Fire Resistant RG6
More informationINTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 60092-350 Second edition 2001-06 Electrical installations in ships Part 350: Shipboard power cables General construction and test requirements Installations électriques à bord
More informationThermocouple Cable TRANSMITTING, SENSING, MEASURING
Thermocouple Cable TRANSMITTING, SENSING, MEASURING Our Commitment Our commitment to our customers is simple - we deliver even when others can t. As one of Canada s largest wire, cable and data communication
More informationSchedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK
2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Presley House Presley Way Crownhill Milton Keynes MK8 0ES United Kingdom Contact: Jeremy Hodge Tel: +44 (0) 1908 267300 Fax: +44 (0) 1908
More informationSTUDY ON THE REACTION TO FIRE OF MEDIUM VOLTAGE CABLES SYSTEMS
STUDY ON THE REACTION TO FIRE OF MEDIUM VOLTAGE CABLES SYSTEMS Neus GENERÓ, Juan de Dios MARTÍNEZ, Jacint ROVIRA, Grupo General Cable Sistemas, (Spain), ngenero@generalcable.es, jdmartinez@generalcable.es,
More informationIDENTIFYING TRAY CABLES FOR YOUR NEXT INSTALLATION A WHITE PAPER
IDENTIFYING TRAY CABLES FOR YOUR NEXT INSTALLATION A WHITE PAPER Published 3/23/2012 T hough rapidly increasing in popularity, tray cables are still a point of confusion for many. While the term tray cable
More informationFIRE PERFORMANCE CABLE
FIRE PERFORMANCE CABLE Manufactured to BS 7629-1 Table 1 Plain Annealed Copper Conductors / Silicone Rubber Insulated / Double Layer of Aluminium/ Polyester Laminated Tapes / Circuit Protective Conductor
More informationPRODUCT RANGE.
PRODUCT RANGE www.ducab.com HIGH VOLTAGE CABLES Manufacturing of XLPE insulated power cables from 60kV 500kV Conductors in either copper or aluminium Conductor sizes from 150mm 2 2500mm 2 Cables are currently
More informationMethod of test defined in IEC for determining the circuit integrity performance of a cable under fire conditions.
Method of test defined in IEC 60331-21 for determining the circuit integrity performance of a cable under fire conditions. WF Report Number: 148371 Test Sponsor: FTC - Fabbrica Trentina Conduttori Srl
More informationMore than Just a Cable Supplier
More than Just a Cable Supplier Leading producer of cables and cable systems The TELE-FONIKA Kable Group has been present on the domestic and international cable industry market for more than 25 years.
More informationBS EN : Measurements Of Smoke Density Of Electric Cables. WF Report Number. Date: 17 th November Test Sponsor:
BS EN 61034-2: 2005 Measurements Of Smoke Density Of Electric Cables WF Report Number 177599 Date: 17 th November 2008 Test Sponsor: FTC Fabbrica Trentina Conduttori Srl 0249 Page 2 of 13 Bodycote warringtonfire
More informationFIRE RESISTANT CABLES FP PLUS. New Generation. Now with enhanced Insudite TM insulation
FIRE RESISTANT CABLES FP PLUS New Generation Now with enhanced Insudite TM insulation ENHANCED FIRE RESISTANT CABLES FP PLUS BS7629-1:2008 FP PLUS > Certificate No 077g/02 The new generation of FP PLUS
More informationDNVGL-CP-0401 Edition February 2016
CLASS PROGRAMME Type approval DNVGL-CP-0401 Edition February 2016 The electronic pdf version of this document, available free of charge from http://www.dnvgl.com, is the officially binding version. FOREWORD
More informationCablosam Tapes for Fire-Resistant Cables
Cablosam Tapes for Fire-Resistant Cables 2 Cablosam Tapes for Fire-Resistant Cables We Enable Energy As one of the oldest industrial companies in Switzerland, founded in 1803, we focus on products and
More informationIndustrial Fiber Optic Cables, LSZH Corrugated Armored Cable, Fibers
Features and Benefits Corrugated armor Mechanical protection Low-smoke/zero-halogen (LSZH ) sheath Key life-safety benefit Meets cyclic impact and chemical resistance test Superior performance Tray-rated
More informationSPECIAL ELECTRICAL AND OPTICAL CABLES
SPECIAL ELECTRICAL AND OPTICAL CABLES INTRODUCTION The new high-speed trains and the sensible increase of the traffic, with congested lines, is the result of the latest development of the rail sector.
More informationHELKAMA. Optical Fibre Cables
1 Contents Optical fibres and their characteristics Cable constructions Cable tests Installation, jointing and terminating Manufacturing (pictures) 2 Multimode Fibre (GK) Attenuation and Bandwidth Fibre
More informationSensor and transducer cables
Sensor and transducer cables Special cables for industrial instrumentation Expertise in sensor cables Nexans has a great expertise in research and development of special and customized sensor cables for
More informationITU-T L.63. Safety practice for outdoor installations
International Telecommunication Union ITU-T L.63 TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU (10/2004) SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT
More informationCABLES FOR ALARM AND SAFETY SYSTEMS
CABLES FOR ALARM AND SAFETY SYSTEMS 2 IT S ALL ABOUT RELIABILITY. It is always important to choose high quality cables, especially when it comes to alarms and safety systems. Even small and seemingly insignificant
More informationFire alarm cables. for highest safety requirements TRADITION INNOVATION PASSION
Fire alarm cables for highest safety requirements TRADITION INNOVATION PASSION Datwyler Datwyler Cabling Solutions is an internationally operating company with its headquarters in Switzerland and affiliates
More information(Notices) EUROPEAN COMMISSION
14.8.2012 Official Journal of the European Union C 245/1 IV (Notices) NOTICES FROM EUROPEAN UNION INSTITUTIONS, BODIES, OFFICES AND AGENCIES EUROPEAN COMMISSION Commission communication in the framework
More information