Low Smoke Zero Halogen

Size: px
Start display at page:

Download "Low Smoke Zero Halogen"

Transcription

1 Low Smoke Zero Halogen Cable for Marine Applications 621 Time Saver Avenue Harahan, LA Call Toll Free: (888) Marine Division summit.com/marine

2 Power and Control Cable M2XH Cable Structure 1 - Conductor: Electrolytic, stranded, annealed copper wire. EC Class 5 (Class 2 and/or tinned on request). 2 - Insulation: Low smoke, halogen free, cross linked, polyethylene compound (XLPE). 3 - Separator: Separating foil or halogen free, bedding compound on request. 4 - Outer Sheath: Low smoke, halogen free, flame retardant, thermoplastic, polyolefin-based compound (HM4 / SHF1) - HD 604. Color: Gray Production and Test Standards Construction...IEC / 353 Tests and Material...IEC / Flame Retardation...IEC / 1, IEC / 3 Cat A Halogen Content...IEC / 1-2 Smoke Density...IEC / 1-2 (DIN EN / 1-2) Working Temperature C / +90 C Min. Bending Radius (Fixed)...6 x Overall Diameter Rated Voltage / 1 kv Test Voltage kv Application Used as fixed installation cables in various electromechanical and electronic equipment of marine vehicles. Usable in all conditions of a marine environment such as dry, wet or oily locations. 2 (888)

3 Product Specifications M2XH Power and Control Cable Part # Sizes mm 2 Designation O.D. inches x 1.5 D x 2.5 D x 4 D x 6 D x 10 D x 16 D x 25 D x 1.5 T x 2.5 T x 4 T x 6 T x 10 T x 16 T x 25 T x 35 T x 50 T x 70 T x 95 T x 120 T x 150 T x 185 T x 240 T x 1.5 F x 2.5 F x 4 F x 6 F Part # Sizes mm 2 Designation O.D. inches x 10 F x 16 F x 25 F x 35 F x 50 F x 70 F x 95 F x 120 F x 150 F x 185 F x 1.5 M x 2.5 M x 4 M x 1.5 M x 2.5 M x 4 M x 1.5 M x 2.5 M x 2.5 M x 1.5 M x 2.5 M x 1.5 M x 2.5 M x 1.5 M x 2.5 M x 1.5 M summit.com/marine 3

4 Shielded Control Cable M2XCH Cable Structure 1 - Conductor: Electrolytic, stranded, annealed copper wire. IEC Class 5 (Class 2 and/or tinned on request). 2 - Insulation: Low smoke, halogen free, cross linked, polyethylene compound (XLPE). 3 - Shield: Electrolytic, copper-braided shield (90% coverage). M2XCH (EMC) type is wrapped by a copper tape in addition to this shield (100% coverage). 4 - Outer Sheath: Low smoke, halogen free, flame retardant, thermoplastic, polyolefin-based compound (HM4 / SHF1) - HD 604. Color: Gray Production and Test Standards Construction... IEC / 353 Tests and Material... IEC / Flame Retardation... IEC / 1, IEC / 3 Cat A Halogen Content... IEC / 1-2 Smoke Density... IEC / 1-2 (DIN EN / 1-2) Shielding Effectiveness (for EMC type)... DIN EN Working Temperature C / +90 C Min. Bending Radius (Fixed)... 8 x Overall Diameter Rated Voltage / 1 kv Test Voltage kv Application Used as fixed installation cables in various electromechanical and electronic equipment of marine vehicles. Usable in all conditions of a marine environment such as dry, wet or oily locations. 4 (888)

5 Product Specifications M2XCH Shielded Control Cable Part # Sizes mm 2 Designation O.D. inches x 2.5 TS x 4 TS x 1.5 FS x 2.5 FS x 4 FS x 25 FS x 1.5 MS x 2.5 MS Part # Sizes mm 2 Designation O.D. inches x 2.5 MS x 1.5 MS x 2.5 MS x 1.5 MS x 1.5 MS x 2.5 MS x 1.5 MS x 2.5 MS x 1.5 MS summit.com/marine 5

6 VFD Cable M2XCH-VFD Cable Structure 1 - Conductor: Circular stranded annealed electrolytic copper conductor (Class 5 according to IEC 60228) 2 - Insulation: Low smoke, halogen free, cross linked, polyethylene compound (XLPE). 3 - Filler and Bedding: Halogen-free, flame-retardant, thermoplastic polyolefin-based compound in between the inner sheath and the insulation of the conductor. (HM4/SHF1 - according to IEC /360) 4 - Screen: CU/PETP tape (100% coverage). Electrolytic copper braided screen (90% coverage density). 5 - Outer Sheath: Halogen free, flame retardant, thermoplastic, polyolefin-based compound (HM4 / SHF1 - according to IEC /360) Production and Test Standards Construction... IEC & IEC /350 Conductor Material... IEC Insulation Material... IEC Sheath Material... IEC Flame Retardance... IEC Halogen-Free Properties... IEC & IEC Low-Smoke Emission... IEC & IEC Tests... IEC Choice & Installation... IEC Min. Bending Radius (Fixed)... 6 x Overall Diameter Min. Bending Radius (during installation)... 8 x Overall Diameter Application Used as fixed installation cables in various electromechanical and electronic equipment of marine vehicles. Usable in all conditions of a marine environment such as dry, wet or oily locations. 6 (888)

7 Product Specifications M2XCH-VFD VFD Cable Part # Sizes (mm 2 ) Designation O.D. (inches) x x6 T-26 VFD x x6 T-41 VFD 1.02 * 3 x x6 T-66 VFD x x10 T-106 VFD 1.31 * 3 x x16 T-133 VFD x x16 T-212 VFD 1.63 * 3 x x25 T-250 VFD 1.86 * 3 x x25 T-300 VFD 2.02 * 3 x x35 T-400 VFD 2.16 * 3 x x50 T-500 VFD 2.41 *Available upon request. Contact Summit s Marine Division at (888) for more details. summit.com/marine 7

8 Overall Shielded Instrumentation Cable FM2XAH Cable Structure 1 - Conductor: Electrolytic, stranded, annealed copper wire. IEC Class 5 (Class 2 and/or tinned on request). 2 - Insulation: Low smoke, halogen free, cross linked, polyethylene compound (XLPE). Layup: Cores laid up in pairs; pairs laid up concentrically. 3 - Separator: Separating foil below shield. 4 - Drain Wire: Electrolytic, tinned, stranded, copper drain wire below shield. 5 - Shield: Aluminum tape shield (100% coverage). 6 - Separator: Separating foil above shield. 7 - Outer Sheath: Low smoke, halogen free, flame retardant, thermoplastic, polyolefin-based compound (HM4 / SHF1) - HD 604. Color: Gray Production and Test Standards 6 5 Construction... IEC / Tests and Material... IEC / Flame Retardation... IEC / 1, IEC / 3 Cat A Halogen Content... IEC / 1-2 Smoke Density... IEC / 1-2 (DIN EN / 1-2) Working Temperature C / +90 C Min. Bending Radius (Fixed)... 8 x Overall Diameter Rated Voltage / 250 V Test Voltage kv Application Used as control and communication cables in radio, radar and information systems for marine applications. Enables proper transmission of high frequency signals while minimizing environmental electromagnetic interference. Usable in all conditions in marine environment such as dry, wet or oily locations, and inside engine rooms (888)

9 Product Specifications FM2XAH Overall Shielded Instrumentation Cable Part # Sizes mm2 Designation O.D. inches x 2 x 1.5 TPS16-1P x 2 x.75 TPS18-1P x 2 x.50 TPS20-1P 0.28 Part # Sizes mm2 Designation O.D. inches x 2 x 2.5 TPS x 3 x 1.5 TTS x 3 x 2.5 TTS summit.com/marine 9

10 Individually and Overall Shielded Instrumentation Cable FM2XAAH Cable Structure 1 - Conductor: Electrolytic, stranded, annealed copper wire. IEC Class 5 (Class 2 and/or tinned on request). 2- Insulation: Low smoke, halogen free, cross linked, polyethylene compound (XLPE). Layup: Cores laid up in pairs/triads; pairs/triads laid up concentrically. 3 - Separator: Separating foil over pairs/triads 4 - Drain Wire: Electrolytic, tinned, stranded, copper drain wire along each pair/triad. 5 - Individual Shield: Aluminum tape shield over each pair/triad and drain-wire bunch (100% coverage). 6 - Separator: Separating foil above shield or inner sheath (on request). 7 - Drain Wire: Electrolytic, tinned, stranded, copper drain wire below overall shield. 8 - Overall Shield: Aluminum tape overall shield (100% coverage). 9 - Separator: Separating foil over overall shield. 10 -Outer Sheath: Low smoke, halogen free, flame retardant, thermoplastic, polyolefin-based compound (HM4/SHF1) HD 604. Color: Gray Production and Test Standards Construction... IEC / 376 Tests And Material... IEC / Flame Retardation... IEC / 1, IEC / 3 Cat A Halogen Content... IEC / 1-2 Smoke Density... IEC / 1-2 (DIN EN / 1-2) Working Temperature C / +90 C Min. Bending Radius (Fixed) x Overall Diameter Rated Voltage... 60/250 V Test Voltage kv Application Used as control and communication cables in radio, radar and information systems for marine applications. Enables proper transmission of high frequency signals while minimizing environmental electromagnetic interference. Usable in all conditions in marine environment such as dry, wet or oily locations, and inside engine rooms. 10 (888)

11 Product Specifications FM2XAAH Overall Shielded Instrumentation Cable Part # Sizes mm 2 Designation O.D. in inches x 2 x 2.5 TPS14-2P x 2 x 1.5 TPS16-2P x 2 x.75 TPS18-2P x 2 x.50 TPS20-2P x 2 x 1.5 TPS16-4P x 2 x.75 TPS18-4P x 2 x.50 TPS20-4P x 2 x.75 TPS18-5P x 2 x 1.5 TSP16-6P x 2 x.75 TPS18-6P 0.70 Part # Sizes mm 2 Designation O.D. in inches x 2 x.50 TPS20-6P x 2 x 1.5 TPS16-7P x 2 x 2.5 TPS14-7P x 2 x 1.5 TPS16-10P x 2 x.75 TPS18-10P x 2 x.50 TPS20-10P x 2 x 1.5 TPS16-12P x 2 x 1.5 TPS16-14P x 2 x.75 TPS18-15P x 2 x 1.5 TPS16-15P 1.10 summit.com/marine 11

12 Single Insulated Conductor Cable M2X Cable Structure 1 - Conductor: Electrolytic, stranded, annealed copper wire IEC Class 5 (Class 2 and/or tinned on request). 2 - Insulation: Low smoke, halogen free, flame retardant, cross linked, polyolefin compound (HF90). Color: Black (other colors available on request). Double insulation is available on request. 2 1 Production and Test Standards Construction...IEC / 353 Tests And Material...IEC / Flame Retardation...IEC / 1, IEC / 3 Cat A Halogen Content...IEC / 1-2 Smoke Density...IEC / 1-2 (DIN EN / 1-2) Working Temperature C / +90 C Min. Bending Radius (Fixed)...4 x Overall Diameter Rated Voltage / 1 kv Test Voltage kv Application Used as fixed installation cables in various electromechanical and electronic equipment, including marine switchboards. Usable in all conditions in marine environment, such as dry, wet or oily locations. 12 (888)

13 Product Specifications M2X Single Insulated Conductor Cable Part # Sizes (mm 2 ) Designation O.D. (inches) * 1 x 0.50 S * 1 x 0.75 S * 1 x 1.5 S * 1 x 2.5 S * 1 x 4 S x 6 S * 1 x 10 S x 16 S x 25 S Part # Sizes (mm 2 ) Designation O.D. (inches) x 35 S x 50 S x 70 S x 95 S x 120 S x 150 S x 185 S * 1 x 240 S *Available upon request. Contact Summit s Marine Division at (888) for more details. summit.com/marine 13

14 Fire Resistant and Flame Retardant Instrumentation and Telecommunication Cable BU(I) (NEK 606 S13) RED Cable Structure 1 - Conductor: Electrolytic, stranded, tinned copper wire. IEC Class Insulation: Halogen free EPR or halogen free HEPR. (All cable to be IEEE-45 color code.) 3 - Separator: Mica tape over conductor 4 - Lay Up: Cores laid up in pair, pairs laid up concentrically 5 - Drain Wire: Electrolytic, stranded, tinned copper drain wire along with every pair/triad. 6 - Screen: Electrolytic copper-backed polyester tape screen (100% coverage) over every pair/triad and drain wire 7 - Outer Sheath: SHF2 (SHF MUD on request). Color: Red Production and Test Standards Construction...NEK 606 S13, IEC / 376 Tests And Material...IEC / Flame Retardation...IEC / 1, IEC / 3 Cat A Fire Resistance...IEC Halogen Content...IEC / 1-2 Smoke Density...IEC / 1-2 (DIN EN / 1-2) Working Temperature C / +90 C Min. Bending Radius (Fixed)...8x Overall Diameter Rated Voltage V Test Voltage kv Application Used as fixed installation cables in various electromechanical and electronic equipments, emergency and critical systems as well as electric distribution and lightning systems. 14 (888)

15 Product Specifications BU(I) (NEK 606 S13) RED Fire Resistant, Flame Retardant Instrumentation and Telecommunications Cable Part # Sizes (mm 2 ) Designation O.D. in inches x 2x 1.5 BU TPS x 2 x 1.5 BU TPS summit.com/marine 15

16 Fire Resistant and Flame Retardant Power Cable BU (NEK 606 P17) RED Cable Structure 1 - Conductor: -Conductor: Electrolytic, stranded, tinned copper wire. IEC Class Insulation: Halogen free EPR. (All cable to be IEEE-45 color code.) 3 - Separator: Mica tape over conductor 4 - Outer Sheath: SHF2. Color: Red Production and Test Standards Construction...NEK 606 P17, IEC / 353 Tests and Material...IEC / Flame Retardation...IEC / 1, IEC / 3 Cat A Fire Resistance...IEC Halogen Content...IEC / 1-2 Smoke Density...IEC / 1-2 (DIN EN / 1-2) Working Temperature C / +90 C Min. Bending Radius (Fixed)...7x Overall Diameter Rated Voltage...0.6/1 kv Test Voltage kv Application Used as fixed installation cables in various electromechanical and electronic equipments, emergency and critical systems as well as electric distribution and lightning systems. 16 (888)

17 Product Specifications BU (NEK 606 P17) Fire Resistant and Flame Retardant Power Cable Part # Sizes (mm 2 ) Designation O.D. (inches) x 1.5 BU 16/7C x 1.5 BU 16/19C x 2.5 BU 14/3C x 2.5 BU 14/4C x 2.5 BU 14/7C 0.66 Part # Sizes (mm 2 ) Designation O.D. (inches) x 2.5 BU 14/10C x 6 BU 10/2C x 6 BU 10/3C x 16 BU 6/4C x 25 BU 4/4C 0.93 summit.com/marine 17

18 Fire Resistant Instrumentation and Telecommunication Cable BFOU(I) (NEK 606 S3/S7) Cable Structure 1 - Conductor: -Electrolytic, stranded, tinned copper wire IEC Class 2 (Class 5 on request). 2 - Separator: Mica tape over conductor 3 - Insulation: Halogen free EPR or Halogen free HEPR 4 - Layup: Cores laid up in pairs/triads, pairs/triads laid up concentrically. 5 - Drain Wire: Electrolytic, stranded, tinned copper drain wire along witp every pair/triad 6 - Screen: Electrolytic copper backed polyester tape screen (100% coverage) over every pair/triad and drain wire. 7 - Bedding: Halogen free compound. 8 - Screen: Electrolytic, tinned copper braided screen ( 90% coverage ). 9 - Outer Sheath: SHF MUD Production and Test Standards Construction...NEK 606 S3/S7, IEC 60092/376 Tests And Material...IEC / Flame Retardation...IEC /1, IEC / 3 Cat A Fire Resistance...IEC Halogen Content...IEC / 1-2 Smoke Density...IEC / 1-2 ( DIN EN 50268/1-2) Mud Resistance...IEC / 359 Working Temperature C / +90 C Min. Bending Radius (Fixed)...10 x Overall Diameter Rated Voltage...250V Test Voltage kv Application Fixed installation cable for signal and communication. 18 (888)

19 Product Specifications BFOU(I) (NEK 606 S3/S7) Fire Resistant and Flame Retardant Power Cable Part # Sizes (mm 2 ) Designation O.D. (inches) x 2 x /1PR x 2 x /2PR x 2 x /4PR x 2 x /1PR x 2 x /2PR x 2 x /4PR x 2 x /7PR 1.05 Part # Sizes (mm 2 ) Designation O.D. (inches) x 2 x /12PR x 2 x 1 17/18PR x 2 x 1 17/1PR x 2 x /1PR x 2 x /6PR x 2 x /8PR 1.29 summit.com/marine 19

20 Fire Resistant, Flame Retardant, Mud Resistant Power Cable BFOU (NEK 606 P5/P12) Cable Structure 1 - Conductor: -Electrolytic, stranded, tinned copper wire IEC Class 2 (Class 5 on request). 2 - Separator: Mica tape over conductor 3 - Insulation: Halogen free EPR or Halogen free HEPR 4 - Bedding: Halogen free compound. 5 - Screen: Electrolytic, tinned copper braided screen ( 90% coverage ). 6 - Outer Sheath: SHF MUD Production and Test Standards Construction...NEK 606 P5/P12, IEC 60092/353 Tests And MateriaL...IEC / Flame Retardation...IEC /1, IEC / 3 Cat A Fire Resistance...IEC Halogen Content...IEC / 1-2 Smoke Density...IEC / 1-2 ( DIN EN 50268/1-2) Mud Resistance...IEC / 359 Working Temperature C / +90 C Min. Bending Radius (Fixed)...8 x Overall Diameter Rated Voltage...0.6/1kV Test Voltage kv Application Used as fixed installation cables in various electromechanical and electronic equipment, emergency and critical systems as well as electric distribution and lighting systems. 20 (888)

21 Product Specifications BFOU (NEK 606 P5/P12) Fire Resistant, Flame Retardant, Mud Resistant Power Cable Part # Sizes (mm 2 ) Designation O.D. (inches) x /2C x 4 12/2C x 6 10/2C x 10 8/2C x 50 1/0-2C x /3C x /3C x 4 12/3C x 6 10/3C x 10 8/3C 0.81 Part # Sizes (mm 2 ) Designation O.D. (inches) x 16 6/3C x 25 4/3C x 35 2/3C x /4C x 4 12/4C x /7C x /7C x /10C x /16C x /20C 1.21 summit.com/marine 21

22 Index of Manufacturers In addition to wire and cable, Summit s Marine Division offers a full array of marine electrical products. Audio/Visual Signals Sirens/Bells/Horns/ SignalLights Federal Signal Ballasts Fluorescent/HID Universal Lighting Technologies Banding 316 SS Banding/Buckles Hayata Coated 316 SS Banding/ Buckles Hayata Batteries Industrial AAA/AA/C/D/ Trans/Lantern Rayovac Shipboard Battery Systems / Flooded and Gel Cell Interstate Batteries Cable Glands Marine/Industrial General Duty Gland CMP Hawke Marine / Industrial Class 1, Division 1 & 2 Gland CMP Hawke Cable Termination 250V / 600V / High Voltage Panduit Raychem Thomas & Betts Cable Tray Steel/Aluminum/Marine Rung B-Line by Eaton Niedax Fiberglass Ladder Chalfant Cables / Industrial MV 90/IAC/CLX/Control/ Instrumentation Okonite MV 90/IAC/Control/ Instrumentation/DLO Southwire MV 90/IAC/Control/ Instrumentation/Welding/ DLO AIW Control/Instrumentation/ Fiber Optic/IAC Belden Caulking Silicone GE Plastics USCG Approved Fire Stop Caulk Nelson Chemicals Wire Lube/Cleaners Ideal Lubricants/Cleaners/Solvents CRC Conduit Rigid Galvanized Steel LTV Shamrock Allied Rigid Stainless Steel Gibson Rigid Aluminum Easco Indalex Plastic Coated Plastibond Sealtight Anaconda Flexible Anaconda Conduit Fittings Malleable/Cast/Aluminum/ Steel Crouse-Hinds by Eaton Thomas & Betts Cast Alumimum Crouse-Hinds by Eaton Plastic Coated Plastibond Die Cast Steel Crouse-Hinds by Eaton Conduit Hubs Cast/Steel/Aluminum/SS Crouse-Hinds by Eaton/ Myers Cord Grips Aluminum Gland Type Grip Remke Nylon Gland Type Grip Kleinhuis (Niedax) Crane Control Crane Brake Parts Eaton (Cutler-Hammer) Distribution Gear Panel Boards/ Power Distribution Eaton (Cutler-Hammer) Westinghouse Military Spec. Navy Breakers/Shock & Vibration Eaton (Cutler-Hammer) Westinghouse Electricians Supplies Hand Tools Klein Tools Ideal Emergency Lighting Battery Operated Teledyne / Big Beam Chloride Dual Lite Excide Safety Systems Enclosures NEMA/Steel/Aluminum/SS Crouse-Hinds by Eaton Hoffman NEMA/Fiberglass Hoffman Flashlights Mini/D Cell/Lantern Rayovac Bright Star Fuses Glass/250V/600 V/ High Voltage Mersen European Fuses Mersen Grounding Systems Rods and Fittings Cadweld Heat Shrink Tubing Thick/Thin Wall Tubing Panduit 3M Raychem Industrial Lighting Fixtures Incandescent/Fluorescent/ HID Crouse-Hinds by Eaton Phoenix Fluorescent Mobern Industrial Reelites Electrical/Pneumatic Crouse-Hinds by Eaton Instruments Voltage/Amperes/Continuity Fluke Greenlee Labels/Markers/Signs Cable Marking/Safety Marking Panduit Hayata Weidmuller Lamps Incandescent/Fluorescent/ HID Sylvania Miniature Sunray Motor Control MCC/Enclosed Control Eaton (Cutler-Hammer) Westinghouse Military Spec. Navy Control/ Parts Eaton (Cutler-Hammer Navy) Navigation Light Panels USCG Approved Custom Panels J - Box Pin & Sleeve Plug & Receptacle Amp/Aluminum Crouse-Hinds by Eaton Amp/Nylon Stahl Portable Cord SO/SEOW/Type W/GGC Southwire Portable Cord Sets & Parts Cord Caps/Cord Sets Woodhead Hubbell Portable Lighting Hand Lamps/Class 1 Division 1/Non Hazard Woodhead Portable Cargo Lights Worklights Inc. Safety Switches Amp./General/ Heavy Duty Eaton (Cutler-Hammer) Shipboard Cable Hanger Commercial Cable Hanging Systems R. T. & D Kindorf Victor Commercial and Military Spec Systems R. T. & D Shipboard Communication Integrated Ship Communications Federal Signal Sound Powered Phones Hose McCann Shipboard General Alarm USCG/Navy Approved Brass Bells Hose McCann General Alarm Panels J-Box Shipboard Light Fixtures Incandescent/Fluorescent/ HID/Bronze/Aluminum/SS Phoenix Incandescent/Fluorescent/ HID/Aluminum/SS Aqua Signal L.C. Doane IRL Shipboard Navigation Lights USCG Approved/Single/ Dual Lamp Aqua Signal Shipboard Wiring Devices Switch/Receptacle/Junctions Phoenix Switch/Receptacle & Related Devices Eaton Strut Systems Slotted/Angled B-Line by Eaton Kindorf Tapes Insulating/Bonding/Color Coding 3M Terminal Blocks Din Rail Mount Weidmuller Terminal Tubes 1/2-4 Mil Spec. Nylon Dorn 1/2-4 Brass/Aluminum/ Male/Female Summit Electric Supply Terminals/Lugs Mechanical/Compression Panduit Burndy Thomas & Betts Timers Electronic/Mechanical Timers Tork Transformers Marine Duty Dry Type 25kVa - 500kVa Eaton (Cutler-Hammer) Westinghouse Dry Type and Oil Filled / SS Clad Olsun Oil Filled/SS Clad Van Tran Control Power Eaton (Cutler-Hammer) Machine Tool Acme Transformer Dry Type Distribution Acme Transformer Transit Barriers/MCTs Multi Diameter/Fire/Water/ Gas Rated Roxtec Tyraps Wire Securing Devices, Nylon & SS Panduit Hayata Thomas & Betts Wire Connectors Wire Nuts Ideal Wing Nuts 3M Wiring Devices Switches/Receptacles Cooper Wiring Devices Woodhead 22 (888)

23 CIrcular Mills AWG / / / / MCM MCM MCM MCM Rated Cross-Section at Metric Systems mm Equivalent Metric C.S.A. mm 2 U.S. Wire Gauge / / / / AWG or MCM AWG MCM summit.com/marine 23

24 The Industrial Marine Experts Low Smoke, Zero Halogen Marine Cable is In Stock Fires on board vessels can produce toxic gases and heavy smoke. Our marine low smoke, zero halogen (LSZH) cable can minimize the effects from these dangers. Save lives, protect your equipment from damage, and meet specifications that require use of LSZH cable. This cable is a low-cost alternative to the military spec cable often used in commercial applications. Ship-Set Quantities Available We stock a wide range of material to satisfy your immediate needs. Easy Identification Our low smoke, zero halogen cable is color coded to IEEE-45. Reduced Time and Labor Costs This ABS-approved cable offers flexible stranding and is easy to strip and terminate. In-house, custom cable armoring is available on request. Call for more information. Tested and Approved to IEC Standards This LSZH cable meets IEC standards for flame retardation, smoke density and halogen content. Top Construction Rating Cable construction is XLPE Insulation/SHF-1 Jacket. Get fast turn around and low minimums on non-stock items and special constructions. Marine Division 621 Time Saver Avenue Harahan, LA summit.com/marine Call Toll Free: (888) marine@summit.com

CIR CRUSH & IMPACT RESISTANT OIL & GAS CABLES

CIR CRUSH & IMPACT RESISTANT OIL & GAS CABLES CIR CRUSH & IMPACT RESISTANT OIL & GAS CABLES Gexol CIR Crush and Impact Resistant Without External Armoring Passes the same stringent crush and impact testing required by UL 2225 for Type MC-HL Index

More information

CIR AG Power Cables. CIR AG Control Cable. CIR Type VFD Cable. CIR AG Ratings & Approvals. n UL Listed as Type TC-ER n UL Listed as TC-ER-HL (E123629)

CIR AG Power Cables. CIR AG Control Cable. CIR Type VFD Cable. CIR AG Ratings & Approvals. n UL Listed as Type TC-ER n UL Listed as TC-ER-HL (E123629) Gexol CIR ARCTIC GRADE (AG) Crush and Impact Resistant Without External Armoring Passes the same stringent crush and impact testing required by UL 2225 for Type MC-HL n Shortest Lead Times Standard 8-10

More information

CIR CRUSH & IMPACT RESISTANT ARCTIC GRADE OIL & GAS CABLES

CIR CRUSH & IMPACT RESISTANT ARCTIC GRADE OIL & GAS CABLES CIR CRUSH & IMPACT RESISTANT ARCTIC GRADE OIL & GAS CABLES Gexol CIR ARCTIC GRADE (AG) Crush and Impact Resistant Without External Armoring Passes the same stringent crush and impact testing required by

More information

Catalogue Telecommunication Cables INTRODUCCIÓN

Catalogue Telecommunication Cables INTRODUCCIÓN Catalogue Telecommunication Cables INTRODUCCIÓN Conductores Tecnológicos S.A. www.contecsa.es Index of Cables Page Introduction 3 EAP / EAP-R 4 EAPSP / EAPSP-R 5 ISP / ICP 6 Conductores Tecnológicos S.A.

More information

CORFLEX. TYPE MC-HL & MV-105 or MC-HL OIL & GAS CABLES

CORFLEX. TYPE MC-HL & MV-105 or MC-HL OIL & GAS CABLES CORFLEX TYPE MC-HL & MV-105 or MC-HL OIL & GAS CABLES INDEX Instrumentation Cables - Pairs and Triads (0V*)... 2 - The Original MC-HL Technology In 1958 Canada Wire and Cable, which s now part of Nexans,

More information

Power Cables. Introduction 3 RV 4 RVMV 5 RVSV 6 RVFV 7. ELECWIRES 2 Page

Power Cables. Introduction 3 RV 4 RVMV 5 RVSV 6 RVFV 7. ELECWIRES 2  Page Power Cables Power Cables Page Introduction 3 RV 4 RVMV 5 RVSV 6 RVFV 7 ELECWIRES 2 www.elecwires.es INTRODUCTION Power Cables Power cables for electrical installations, domestic & industrial, specifically

More information

Catalogue Power Cables

Catalogue Power Cables Catalogue Power Cables Conductores Tecnológicos S.A. www.contecsa.es Index of Cables Page Introduction 13 RV 14 RVMV 15 RVSV 16 RVFV 17 Conductores Tecnológicos S.A. 2 www.contecsa.es INTRODUCTION Power

More information

Catalogue. Instrumentation & Control Cables

Catalogue. Instrumentation & Control Cables Catalogue Instrumentation & Control Cables Conductores Tecnológicos S.A. www.contecsa.es Index of Cables Page Introduction 3 Instrumentation VOV 4 VHOV 5 VOVMV 6 VHOVMV 7 Control RV 8 RZ1C3Z1 9 Conductores

More information

PRODUCT CATALOGUE Norröna

PRODUCT CATALOGUE  Norröna PRODUCT CATALOGUE Norröna WWW.SCANKAB.COM Table of contents MARINE AND OFFSHORE CABLES 1 TOXFREE XZ1-K (AS) - 0.6/1 kv 1 TOXFREE MARINE XO2TCuZ1-K (AS) - 150/250 V 5 4x2xAWG 24/1 CAT6 S/FTP LSZH-SHF1 -

More information

PHOTOVOLTAIC CABLES. Photovoltaic Cable 2000V/1500V Photovoltaic Cable 2000V/1000V

PHOTOVOLTAIC CABLES. Photovoltaic Cable 2000V/1500V Photovoltaic Cable 2000V/1000V PHOTOVOLTAIC CABLES PHOTOVOLTAIC CABLES INDEX n AmerSol Dual-Certified (UL / ETL) Photovoltaic Cable 2000V/1500V....................... 2-3 n AmerSol Dual-Certified (UL / ETL) Photovoltaic Cable 2000V/1000V.......................

More information

Flexible Power Cable DLO

Flexible Power Cable DLO 37-119 Flexible Power Cable DLO 2000 Volts 90 C Diesel Locomotive Cable Limited Smoke (Sizes 2/0 and higher) EP/CPE RHH, RHW-2 Flexible-stranded, tin-coated annealed copper Flame retardant, oil and sunlight

More information

DNVGL-CP-0401 Edition February 2016

DNVGL-CP-0401 Edition February 2016 CLASS PROGRAMME Type approval DNVGL-CP-0401 Edition February 2016 The electronic pdf version of this document, available free of charge from http://www.dnvgl.com, is the officially binding version. FOREWORD

More information

DNVGL-CP-0399 Edition March 2016

DNVGL-CP-0399 Edition March 2016 CLASS PROGRAMME Type approval DNVGL-CP-0399 Edition March 2016 The electronic pdf version of this document, available free of charge from http://www.dnvgl.com, is the officially binding version. FOREWORD

More information

Shipboard & Offshore Cables

Shipboard & Offshore Cables Shipboard & Offshore Cables Shipboard & Offshore Cables Páge Introduction 3 Power Cables XL / XL-FR 5 XC4L / XC4L-FR 6 XLC4L / XLC4L-FR 7 Instrumentation cables XHL / XHL-FR 8 XOL / XOL-FR 9 XHC4L / XHC4L-FR

More information

Telecommunication Cables

Telecommunication Cables Telecommunication Cables Telecommunication Cables Introduction 3 EAP / EAP-R 4 EAPSP / EAPSP-R 5 ISP / ICP 6 Page ELECWIRES 2 www.elecwires.es INTRODUCCIÓN Telecommunication Cables Telephone cables suitable

More information

CORFLEX TYPE MC-HL POWER, CONTROL & INSTRUMENTATION CABLES

CORFLEX TYPE MC-HL POWER, CONTROL & INSTRUMENTATION CABLES CORFLEX TYPE MC-HL POWER, CONTROL & INSTRUMENTATION CABLES CORFLEX TYPE MC-HL POWER, CONTROL & INSTRUMENTATION CABLES INDEX Corflex MC-HL Instrumentation - Pairs and Triads (0V*)... 1 - CORFLEX Cables

More information

INTRODUCTION. Our diverse range of world-class Specialty Insulated Wires and Cablesinclude: LV Cables -

INTRODUCTION. Our diverse range of world-class Specialty Insulated Wires and Cablesinclude: LV Cables - MARINE CABLES Your Power Partner on the Seas INTRODUCTION We, a member of the Al-Bahja Group of Companies, are an ISO:900:2008 BASEC, UK certified integrated quality producer of LV and MV Cables, Wires&

More information

Flame Retardant Overall Screened Instrumentation Cables (multicore)

Flame Retardant Overall Screened Instrumentation Cables (multicore) Flame Retardant Overall Screened Instrumentation Cables (multicore) RE-2X(St)H RE-2X(St)HSWAH LSZH Outer Sheath Tinned Copper Drain Wire LSZH Inner Sheath XLPE Insulation Plain Annealed Copper Aluminium/polyester

More information

Caledonian Flame Retardant Coaxial Cables

Caledonian Flame Retardant Coaxial Cables Caledonian Flame Retardant Coaxial Cables www.caledonian-cables.co.uk www.addison-cables.com Flame Retardant RG59 Coaxial cables LSZH Outer Sheath Tinned Copper Braid Aluminium+polyester/Aluminium Tape

More information

1.1 Preferred Manufacturers are manufacturers of products that have worked well for the University on past projects.

1.1 Preferred Manufacturers are manufacturers of products that have worked well for the University on past projects. DIVISION 26 (ELECTRICAL) PREFERRED MANUFACTURERS GENERAL INFORMATION 1.1 Preferred Manufacturers are manufacturers of products that have worked well for the University on past projects. 1.2 This list is

More information

OFFSHORE CABLES. Top Cable Central Headquarters. Leonardo Da Vinci, number Rubí (Barcelona) Spain

OFFSHORE CABLES.   Top Cable Central Headquarters. Leonardo Da Vinci, number Rubí (Barcelona) Spain Top Cable Central Headquarters Leonardo Da Vinci, number 1 08191 Rubí (Barcelona) Spain OFFSHORE CABLES Tel +4 9 586 21 78 +4 9 586 21 68 Fax +4 9 586 21 65 sales@topcableoffshoremarine.com http://www.topcableoffshoremarine.com

More information

Flexflame. Arctic Grade Cables for Extreme Conditions. Photo: Sakhalin Energy Investement Company Ltd.

Flexflame. Arctic Grade Cables for Extreme Conditions. Photo: Sakhalin Energy Investement Company Ltd. Flexflame Arctic Grade Cables for Extreme Conditions Photo: Sakhalin Energy Investement Company Ltd. Linking the future Draka Norsk Kabel is a part of Prysmian Group, a worldwide leader in the cable industry.

More information

Power Control Cable Iec

Power Control Cable Iec POWER CONTROL CABLE IEC 60502 1 PDF - Are you looking for power control cable iec 60502 1 Books? Now, you will be happy that at this time power control cable iec 60502 1 PDF is available at our online

More information

High Performance LSZH Fire Resistant Cable

High Performance LSZH Fire Resistant Cable High Performance LSZH Fire Resistant Cable www.cavicel.com 104/2 FIRECEL SR 114H is the long and well established CAVICEL fire resistant cable in the market, since many years. These cables are third party

More information

Caledonian Fire resistant Coaxial Cables

Caledonian Fire resistant Coaxial Cables Caledonian Fire resistant Coaxial Cables www.caledonian-cables.net www.addison-cables.com Fire resistant rg59 b/u Coaxial Cables RG59 B/U FR LSZH Sheath Fire Resistant Tape Copper Clad Steel/Bare Copper

More information

Caledonian fire Resistant signal & Data cables

Caledonian fire Resistant signal & Data cables fire Resistant signal & Data cables www.addison-tech.com fire Resistant Rs485 Databus cables Copper Wire Braid(optional) Individual AL/Polyester Tape(optional) Mica Glass Tape+PE/PE+Silicone Rubber Insulation

More information

IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission

IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission ADDISON Flame Retardant CAT5e Data Cables FTX-CAT5e U/UTP4P24 FTX-CAT5e f/utp4p24 FTX-CAT5e sf/utp4p24 LSZH Outer Aluminium/Polyester Tape Solid Copper Conductor PE Insulation Tinned Copper Drain Wire

More information

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017 SECTION 26 0519 LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions

More information

600/1000V XLPE Insulated, LSZH Sheathed, Double steel tape Armoured Power Cables (3 Cores)

600/1000V XLPE Insulated, LSZH Sheathed, Double steel tape Armoured Power Cables (3 Cores) Caledonian Flame Retardant Power & Control Cables www.caledonian-s.co.uk www.addison-s.com 600/1000V XLPE Insulated, LSZH Sheathed, Double steel tape Armoured Power Cables (3 Cores) FTX400 1RZ1MZ1-R (CU/XLPE/LSZH/DSTA/LSZH

More information

Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design.

Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design. ADDISON Flame Retardant RG59 B/U Coaxial cables Plain copper wire braid PE Solid Bare Copper PVC Outer Sheath APPLICATION The cables are designed for CCTV, security, smoke detection and evacuation monitoring

More information

IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission

IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission Flame Retardant RS485 Databus Cables Copper Wire Braid(optional) Individual AL/Polyester Tape(optional) Foam PE/Foam skin PE. Stranded Tinned Copper AL/Polyester Tape With Tinned Copper Drain Wire LSZH

More information

QUALITY THROUGH EXPERIENCE

QUALITY THROUGH EXPERIENCE QUALITY THROUGH EXPERIENCE Brief History of ÜNTEL Established in 1972 Partnership of Ünlü and Günan families since then 40 years of manufacturing experience with an extensive production range for various

More information

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards Change History Date Description of Change Pages / Sections Modified Change Approver Initials 8/1/17 Updated section on Manufacturers 3 1. 6/15/16 Updated division section from 16120 to 26 05 00, - mgl44

More information

IEC UNE DESIGN. 1. Conductor. 2. Insulation. Cross-linked polyethylene (XLPE) 3. Outer sheath. Flexible PVC, black colour.

IEC UNE DESIGN. 1. Conductor. 2. Insulation. Cross-linked polyethylene (XLPE) 3. Outer sheath. Flexible PVC, black colour. 67 POWERFLEX RV-K POWERFLEX RV-K Industrial flexible cable for power transmission. 1 IEC 60502-1 - UNE 21123-2 DESIGN 1. Conductor 2 Electrolytic copper, class 5 (flexible), based on EN 60228 and IEC 60228.

More information

Total Fire Solutions. Includes BS 8519 and the updated BS :

Total Fire Solutions. Includes BS 8519 and the updated BS : Total Fire Solutions Includes BS 8519 and the updated BS 5266-1:2011 www.aeicables.co.uk Introduction: Total Fire Solutions Power and control cable systems for life safety and fire-fighting applications

More information

600/1000V SR Insulated Flexibles Control Cables (2-4 Cores & Multicores)

600/1000V SR Insulated Flexibles Control Cables (2-4 Cores & Multicores) 600/1000V SR Insulated Flexibles Control Cables (2-4 Cores & Multicores) FFX400 1SZ1-R(PH60)(CU/SR/LSZH 600/1000V Class 2) FFX400 1SZ1-F(PH60)(CU/SR/LSZH 600/1000V Class 5) Silicone Rubber Insulation Plain

More information

FIRE RESISTANT CABLES

FIRE RESISTANT CABLES Conducting Value The Last Cable Standing FIRE RESISTANT CABLES 100/7b ISO 9001:2008 Certificate No. CS1-249 MANAGEMENT SYSTEMS Assessed to ISO 9001:2008 Cert/LPCB ref. 217 GOST ISO 9001-2011 (ISO 9001:2008)

More information

POINT OBSTRUCTION CONTROLLER POC TOUCHSCREEN CONTROLLERS

POINT OBSTRUCTION CONTROLLER POC TOUCHSCREEN CONTROLLERS POINT OBSTRUCTION CONTROLLER Compliances: FAA Advisory Circular 70/7460-1L ICAO Annex 14, Volume I, Chapter 6 The controller provides the control and monitoring functions for an LED red obstruction lighting

More information

Flame Retardant EP/CPE POWER, CONTROL & INSTRUMENTATION CABLES

Flame Retardant EP/CPE POWER, CONTROL & INSTRUMENTATION CABLES Flame Retardant EP/CPE POWER, CONTROL & INSTRUMENTATION CABLES 37-754 FLAME RETARDANT EP/CPE TYPE TC OR TC-ER POWER CABLE Two Five Conductor + Ground (Two, Three & Four Conductor) 600 V Rated 90 C Conductor*

More information

TYPE APPROVAL CERTIFICATE

TYPE APPROVAL CERTIFICATE TYPE APPROVAL CERTIFICATE Certificate No: TAE00000GG Revision No: 2 This is to certify: That the Data transmission cables and systems with type designation(s) MGD Cat 3, MGD Cat 5, Cat 5e, MGD cat 6, Cat

More information

AFIREFENIX SZ1-K 0,6/1 kv PH120 (AS+)

AFIREFENIX SZ1-K 0,6/1 kv PH120 (AS+) Page 1 / 7 Construction and tests. Standards: UNE 211025 Compliance with the Low Voltage Directive (LVD): 2014/35 / EU Construction Products Regulation (CPR) - Regulation (EU) Nº 305/2011: Reaction to

More information

CONNECTION SYSTEMS TRANSIT APPLICATIONS

CONNECTION SYSTEMS TRANSIT APPLICATIONS CNNECTIN SYSTEMS TRANSIT APPLICATINS Ensure electrical and mechanical reliability with the engineered products and solutions of Shawcor s Connection Systems group INTEGRITY IS BEHIND EVERYTHING WE D. By

More information

BS /1000V XLPE Insulation LSZH Sheath Cables

BS /1000V XLPE Insulation LSZH Sheath Cables BS 8573 600/1000V XLPE Insulation LSZH Sheath Cables Caledonian www.addison-cables.com Company Profile Caledonian & Addison, branded under Caledoniea & Addimax, established in 1978, offers one of the most

More information

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Union County Vocational - Technical Schools Scotch Plains, New Jersey SECTION 220533 - HEAT TRACING FOR PLUMBING PIPING PART 1 - GENERAL 1.1 SUMMARY A. This Section includes plumbing piping heat tracing for freeze prevention, domestic hot-water-temperature maintenance, and

More information

ADVANCE ELECTRICAL MEP CONTRACTING TRADING SERVICES

ADVANCE ELECTRICAL MEP CONTRACTING TRADING SERVICES ADVANCE ELECTRICAL MEP CONTRACTING TRADING SERVICES ABOUT US Quality products, exceptional service and quick delivery of a diverse product line are the foundation of our company. By leveraging the portfolio

More information

(Notices) EUROPEAN COMMISSION

(Notices) EUROPEAN COMMISSION 14.8.2012 Official Journal of the European Union C 245/1 IV (Notices) NOTICES FROM EUROPEAN UNION INSTITUTIONS, BODIES, OFFICES AND AGENCIES EUROPEAN COMMISSION Commission communication in the framework

More information

Tratos Railway Cables

Tratos Railway Cables January 2013 Tratos Railway Cables Cables for a moving world www.tratos.eu Introduction Tratos Cavi is a company specialising in the production of power, signalling, control and telecommunications cables

More information

Compact Module. Category 6A FTP Cabling System 1.1

Compact Module. Category 6A FTP Cabling System 1.1 Updated 24/09/12 Compact Module Cat 6A performance Suitable for 10-Gigabit Ethernet Ultra-slimline design Euro style module Interchangeable with other Euro Modules and blanks Individually QA tested Easy

More information

SECTION LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES

SECTION LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES SECTION 26 05 19 - LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions

More information

IDENTIFYING TRAY CABLES FOR YOUR NEXT INSTALLATION A WHITE PAPER

IDENTIFYING TRAY CABLES FOR YOUR NEXT INSTALLATION A WHITE PAPER IDENTIFYING TRAY CABLES FOR YOUR NEXT INSTALLATION A WHITE PAPER Published 3/23/2012 T hough rapidly increasing in popularity, tray cables are still a point of confusion for many. While the term tray cable

More information

SAS Security and Alarm Safety Cables

SAS Security and Alarm Safety Cables CABLES Security and Alarm Safety Cables Security and Alarm Safety Cables LOW SMOKE ZERO HALOGEN The right range of cables for modern building installations e-catalogue 203/4 Flexible solutions for commercial,

More information

SECTION ELECTRICAL GENERAL PROVISIONS

SECTION ELECTRICAL GENERAL PROVISIONS PART 1 GENERAL 1.01 SECTION INCLUDES A. General provisions for Electrical Systems B. Wire and cable for 600 volts and less. C. Wiring connectors. D. Electrical tape. E. Heat shrink tubing. F. Wire pulling

More information

Wire and Cable. For more information on these Tyco Electronics products, visit the following website:

Wire and Cable. For more information on these Tyco Electronics products, visit the following website: 26 Wire and Cable Raychem High Performance Wire and Cable....26-2 to 26-4 Madison Cable Products...................26-5 to 26-7 Reference the following cables in Section 15 of this catalog: Premises Networking

More information

fire resistant cables

fire resistant cables Building Technology fire resistant cables Special electrical and optical cables www.tecnikabel.com Special electrical and optical cables 2 INTRODUCTION Structured cabling solutions. Tecnikabel can provide

More information

Corra/Clad MC Cable The contractors cable of choice in place of conduit and wire.

Corra/Clad MC Cable The contractors cable of choice in place of conduit and wire. Corra/Clad MC Cable The contractors cable of choice in place of conduit and wire. Installs fast and easy Lowers labor costs Replaces conduit and wire Provides superior grounding UL Listed Corra/Clad MC

More information

Wires, Cables, Cords and Adhesive Tapes

Wires, Cables, Cords and Adhesive Tapes 702-CRC-006-E Revision: 08 Page: 1/34 Elaborated by: Douglas Ferreira Checked by: Nelson A. Coelho Approved by: Arnaldo Barbulio Filho Approval date: 23\08\13 1 OBJECTIVE This document presents the complementary

More information

Thermocouple Cable TRANSMITTING, SENSING, MEASURING

Thermocouple Cable TRANSMITTING, SENSING, MEASURING Thermocouple Cable TRANSMITTING, SENSING, MEASURING Our Commitment Our commitment to our customers is simple - we deliver even when others can t. As one of Canada s largest wire, cable and data communication

More information

The Quality Connection. BETAflam Fire Resistant Safety Cables

The Quality Connection. BETAflam Fire Resistant Safety Cables The Quality Connection BETAflam Fire Resistant Safety Cables BETAflam Contact Your personal customer number To offer you a more efficient service, we kindly ask you to mention your personal customer number

More information

Double insulated, electron-beam cross-linked, halogen free photovoltaic wire sunlight resistant. Single conductor, flame retardant insulation.

Double insulated, electron-beam cross-linked, halogen free photovoltaic wire sunlight resistant. Single conductor, flame retardant insulation. Technical Data Sheet BETAflam Solar 125 flex UL 4703 Description Double insulated, electron-beam cross-linked, halogen free photovoltaic wire sunlight resistant. Single conductor, flame retardant insulation.

More information

OIL & GAS INDUSTRY OTHER INDUSTRIES

OIL & GAS INDUSTRY OTHER INDUSTRIES For ATEX Areas OIL & GAS INDUSTRY OTHER INDUSTRIES OIL & GAS INDUSTRY POTENTIALLY HAZARDOUS Class I GASES VAPORS LIQUIDS Petrosumsave Zone 0 An area in which an explosive mixture is continuously present,

More information

Sensor and transducer cables

Sensor and transducer cables Sensor and transducer cables Special cables for industrial instrumentation Expertise in sensor cables Nexans has a great expertise in research and development of special and customized sensor cables for

More information

IEC NORMAS PUBLICADAS. As normas ISO/IEC já estão relacionadas em normas ISO Publicadas

IEC NORMAS PUBLICADAS. As normas ISO/IEC já estão relacionadas em normas ISO Publicadas IEC NORMAS PUBLICADAS As normas ISO/IEC já estão relacionadas em normas ISO Publicadas IEC/TC 1 - Terminology IEC 60050-161-am5 ed1.0 (2015-02) - Amendment 5 - International Electrotechnical Vocabulary

More information

5. Identification products.

5. Identification products. Essex County College - West Essex Campus Addition And Renovations dib # 54292 / 11-14 [SECTION 260523- CONTROL-VOLTAGE ELECTRICAL POWER CABLES PART 1- GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general

More information

DNVGL-CP-0402 Edition February 2016

DNVGL-CP-0402 Edition February 2016 CLASS PROGRAMME Type approval DNVGL-CP-0402 Edition February 2016 The electronic pdf version of this document, available free of charge from http://www.dnvgl.com, is the officially binding version. FOREWORD

More information

FIRE RESISTANT CABLES FP300

FIRE RESISTANT CABLES FP300 FIRE RESISTANT CABLES FP300 Fire resistant LSOH power cables for fixed wiring FIRE RESISTANT CABLES FP300 LPCB Ref No: 077e/01 FP300 > Prysmian FP300 is designed for cabling essential safety circuits associated

More information

2016 CDM Smith All Rights Reserved July 2016 SECTION FIBER OPTIC DATA NETWORK

2016 CDM Smith All Rights Reserved July 2016 SECTION FIBER OPTIC DATA NETWORK PART 1 GENERAL 1.01 SCOPE OF WORK SECTION 27 12 23 FIBER OPTIC DATA NETWORK A. Furnish, install, terminate, and test all fiber optic equipment and cabling necessary for a complete and functional data highway

More information

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 28 ELEC. SAFETY & SECURITY SECTION CONDUCTORS AND CABLES FOR ELECTRONIC SAFETY AND SECURITY

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 28 ELEC. SAFETY & SECURITY SECTION CONDUCTORS AND CABLES FOR ELECTRONIC SAFETY AND SECURITY SECTION 280513 - CONDUCTORS AND CABLES FOR ELECTRONIC SAFETY AND SECURITY PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Coaxial cabling. 2. RS-232 cabling. 3. RS-485 cabling. 4. Low-voltage control

More information

Table of Contents. TELE-FONIKA KABLE SA (DMCC Branch). 4 TELE-FONIKA Kable Group 6 FLAME-X 950 SERIES 1 11 FLAME-X 950 SERIES 2

Table of Contents. TELE-FONIKA KABLE SA (DMCC Branch). 4 TELE-FONIKA Kable Group 6 FLAME-X 950 SERIES 1 11 FLAME-X 950 SERIES 2 FLAME-X 950 TELE-FONIKA KABLE SA (DMCC Branch). Table of Contents is the Regional Middle East Sales Office of Tele-Fonika Kable S.A. from Poland, 4-th largest manufacturer of electric cables and wires

More information

Comtran Cable. Hub-LINK Cables for Transit Applications

Comtran Cable. Hub-LINK Cables for Transit Applications Comtran Cable Hub-LINK Cables for Transit Applications Overview Hub-LINK rail transit cables are designed to resist the rugged conditions of the underground and at-grade environments, including: Temperature

More information

Photovoltaic Cables EN H1Z2Z2-K

Photovoltaic Cables EN H1Z2Z2-K Photovoltaic Cables EN 50618 H1Z2Z2-K COMPANY PROFILE Caledonian, established in 1978, offers one of the most complete lines of fiber and copper cabling system solutions with over hundreds of different

More information

Havells Fire Survival Cables

Havells Fire Survival Cables Fire Survival Cables Designed for Critical Installation of National Importance Airports / Thermal Power Plants Metro Rail Projects / Rail Terminals / Nuclear Interstate Bus Terminals / Installation Prone

More information

CABLES FOR ALARM AND SAFETY SYSTEMS

CABLES FOR ALARM AND SAFETY SYSTEMS CABLES FOR ALARM AND SAFETY SYSTEMS 2 IT S ALL ABOUT RELIABILITY. It is always important to choose high quality cables, especially when it comes to alarms and safety systems. Even small and seemingly insignificant

More information

SAFE, FAST PROFESSIONAL WIRING SOLUTIONS STANDARDISED & INDIVIDUAL COMPLEX SMART SOLUTIONS. 25 years: You name it. We have it. DANNEWITZ GmbH & Co

SAFE, FAST PROFESSIONAL WIRING SOLUTIONS STANDARDISED & INDIVIDUAL COMPLEX SMART SOLUTIONS. 25 years: You name it. We have it. DANNEWITZ GmbH & Co SAFE, FAST PROFESSIONAL WIRING SOLUTIONS STANDARDISED & INDIVIDUAL COMPLEX SMART SOLUTIONS GmbH & Co 25 years: You name it. We have it. THOROUGHLY THOUGHT OUT SOLUTIONS We offer an extensive product range

More information

North American Cable Glands

North American Cable Glands North American Cable Glands INTRODUCTION Linking the future As the worldwide leader in the cable industry, Prysmian Group believes in the effective, efficient and sustainable supply of energy and information

More information

600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (Multicore)

600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (Multicore) 600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (Multicore) FGD400 1RV-R (CU/XLPE/PVC 600/1000V Class ) FGD400 1RVMV-R (CU/XLPE/PVC/SWA/PVC 600/1000V Class ) PVC Outer Sheath Plain Annealed

More information

Lloyd s Register Type Approval System Test Specification Number 3

Lloyd s Register Type Approval System Test Specification Number 3 Working together for a safer world Lloyd s Register Type Approval System Test Specification Number 3 July 2015 Performance Test Specification for Equipment to be used in Marine Applications: Electric Cables

More information

SECTION LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES (600 VOLTS AND BELOW)

SECTION LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES (600 VOLTS AND BELOW) SECTION 26 05 21 PART 1 - GENERAL 1.1 DESCRIPTION This section specifies the furnishing, installation, and connection of the low voltage power and lighting wiring. 1.2 RELATED WORK A. Excavation and backfill

More information

Author Owner Issue Authority Name: Gordon MacKenzie Title: Senior Engineer Engineering Design and Standards

Author Owner Issue Authority Name: Gordon MacKenzie Title: Senior Engineer Engineering Design and Standards 1. SCOPE This Specification details requirements for General Wiring cables up to and including 450/750V for use on lighting and general power wiring installations complying with BS 7671 but not forming

More information

BS FP600 achieves the maximum 120 minute rating under the BS test conditions, which is required for fire fighting applications.

BS FP600 achieves the maximum 120 minute rating under the BS test conditions, which is required for fire fighting applications. FIRE RESISTANT CABLES FP600 FIRE RESISTANT CABLES FP600 BS7346-6 FP600 > Prysmian FP600 is a unique enhanced performance fire resistant power cable, designed specifically to meet the more onerous fire

More information

Your Partner for Custom Interconnectivity Solutions. ISO 9001:2008 AS9100C:2009 ISO 13485:2003 ISO 17025:2005 Qualified

Your Partner for Custom Interconnectivity Solutions. ISO 9001:2008 AS9100C:2009 ISO 13485:2003 ISO 17025:2005 Qualified Your Partner for Custom Interconnectivity Solutions ISO 9001:2008 AS9100C:2009 ISO 13485:2003 ISO 17025:2005 Qualified LEMO Precision Custom Connection Solutions The Original Push-Pull Connector Seven

More information

CORRIGENDA. (Publication of titles and references of harmonised standards under Union harmonisation legislation)

CORRIGENDA. (Publication of titles and references of harmonised standards under Union harmonisation legislation) C 173/162 EN Official Journal of the European Union 13.5.2016 CORRIGENDA Corrigendum to Commission communication in the framework of the implementation of Directive 2006/95/EC of the European Parliament

More information

F1202 TRACE HEATING. Road & Ramp

F1202 TRACE HEATING. Road & Ramp Trace Heating Specialists Road & Ramp ROAD & RAMP HEATING ESH Trace Heating Ltd provide a comprehensive range of products to prevent the settlement of snow and formation of ice on roads, ramps and stairs.

More information

Caledonian. FIREFLIX ire Resistant Coaxial Cables

Caledonian. FIREFLIX ire Resistant Coaxial Cables Caledonian FIREFLIX ire Resistant Coaxial Cables table OF COntents Fire resistant Coaxial Cables Fire Resistant RG59 B/U coaxial cables...25 Fire Resistant RG6 A/U coaxial cables...28 Fire Resistant RG6

More information

Energy Division Heat-shrinkable joints for halogen-free, flame-retardant and fire-resistand cables up to 1 kv

Energy Division   Heat-shrinkable joints for halogen-free, flame-retardant and fire-resistand cables up to 1 kv Energy Division http://energy.tycoelectronics.com Heat-shrinkable joints for halogen-free, flame-retardant and fire-resistand cables up to 1 kv R Heat-shrinkable joints for halogen-free, flame-retardant

More information

Firecel Safety Cables

Firecel Safety Cables 103/7 Firecel Safety Cables Low Smoke - Zero Halogen www.cavicel.com Firecel Safety Cables Low Smoke - Zero Halogen Over the last 30 years CAVICEL has developped a deep experience in studying, designing

More information

Cablosam Tapes for Fire-Resistant Cables

Cablosam Tapes for Fire-Resistant Cables Cablosam Tapes for Fire-Resistant Cables 2 Cablosam Tapes for Fire-Resistant Cables We Enable Energy As one of the oldest industrial companies in Switzerland, founded in 1803, we focus on products and

More information

(Publication of titles and references of harmonised standards under Union harmonisation legislation) (Text with EEA relevance) (2017/C 298/02)

(Publication of titles and references of harmonised standards under Union harmonisation legislation) (Text with EEA relevance) (2017/C 298/02) C 298/14 EN Official Journal of the European Union 8.9.2017 Commission communication in the framework of the implementation of Directive 2014/35/EU of the European Parliament and of the Council on the

More information

13. UNITED KINGDOM Standards Supply Voltage and Plug Configurations 247

13. UNITED KINGDOM Standards Supply Voltage and Plug Configurations 247 13. UNITED KINGDOM 13.1 Standards 13.1.1 BSI 240 13.1.2 BASEC 242 13.1.3 BBC 242 13.1.4 BNFL 242 13.1.5 BRB 242 13.1.6 British Telecom 243 13.1.7 Department of the Environment 243 13.1.8 Department for

More information

STANDARDS INSTALLATION. Certificate No 077m

STANDARDS INSTALLATION. Certificate No 077m Certificate No 077m > Prysmian FP600 is a unique enhanced performance fire resistant power cable, designed specifically to meet the more onerous fire survival requirements now requested by regulators and

More information

Evolution of Cable Fire Safety Standards in Australia

Evolution of Cable Fire Safety Standards in Australia Evolution of Cable Fire Safety Standards in Australia INTRODUCTION Fire safety standards for electrical cables have evolved over the past few decades to the extent that they are now well established along

More information

Introduction.

Introduction. Introduction The safety of occupants and users of public, commercial and industrial premises is of paramount importance. One important safety feature is the appropriate use of fire performance cables for

More information

ROLLING STOCKS Cables ELECRAIL

ROLLING STOCKS Cables ELECRAIL 3 ROLLING STOCKS Cables ELECRAIL 03/2016 SILICONE HF POLYOLEFIN HF POLYOLEFIN SLEEVES ELECRAIL ELECRAIL ELECRAIL ELECRAIL PHFLE 4 Plastelec Group has been designing, developing, manufacturing and marketing

More information

Cable technology for highest safety requirements

Cable technology for highest safety requirements Cable technology for highest safety requirements Daetwyler We are a provider of high-grade quality system solutions and services in the areas of structured data cabling, telecom carriers, safety cabling,

More information

SECTION CONDUCTORS AND CABLES FOR ELECTRONIC SAFETY AND SECURITY

SECTION CONDUCTORS AND CABLES FOR ELECTRONIC SAFETY AND SECURITY SECTION 280513 CONDUCTORS AND CABLES FOR ELECTRONIC SAFETY AND SECURITY PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions

More information

LV FIRE RESISTANT CABLES

LV FIRE RESISTANT CABLES LV FIRE RESISTANT CABLES CONTENTS 3 GENERAL INTRODUCTION LV FIRE RESISTANT CABLES TECHNICAL INFORMATION 4 9 12 24 26 GENERAL CABLE STRUCTURE ELECTRICAL CHARACTERISTICS CURRENT RATING VOLTAGE DROP SHORT

More information

MEDIUM, LOW AND CONTROL VOLTAGE CABLES

MEDIUM, LOW AND CONTROL VOLTAGE CABLES Related Sections U-M Design Guideline Sections: 260800 - Electrical Acceptance Tests Products Medium Voltage Primary Cables Primary power distribution cable shall be single conductor stranded copper, with

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60092-350 Second edition 2001-06 Electrical installations in ships Part 350: Shipboard power cables General construction and test requirements Installations électriques à bord

More information

AFUMEX LSX LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS:

AFUMEX LSX LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS: PRODUCT DATASHEET & APPLICATIONS GUIDE LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 KEY BENEFITS: BASEC approved for the full size range of BS8436 (1.0mm 2 to 2.5mm 2 ) Additionally tested for

More information

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications Force Pressure Temperature Switch Pressure sensors Ex ia I / IIC T6 acc. to ATEX with internal diaphragm with front flush diaphragm Accuracy: 0,25% and 0,5 % Standard output: 4...20 ma; 2-wire system Description

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK ISO/IEC 17065:2012 to provide product conformity certification Presley Way Crownhill Milton Keynes MK8 0ES Contact: Tracie Hunter Tel: +44 (0)1908 267300 Fax: +44 (0)1908 267255 E-Mail: mail@basec.org.uk

More information