Low Smoke Zero Halogen
|
|
- Laurence Preston
- 5 years ago
- Views:
Transcription
1 Low Smoke Zero Halogen Cable for Marine Applications 621 Time Saver Avenue Harahan, LA Call Toll Free: (888) Marine Division summit.com/marine
2 Power and Control Cable M2XH Cable Structure 1 - Conductor: Electrolytic, stranded, annealed copper wire. EC Class 5 (Class 2 and/or tinned on request). 2 - Insulation: Low smoke, halogen free, cross linked, polyethylene compound (XLPE). 3 - Separator: Separating foil or halogen free, bedding compound on request. 4 - Outer Sheath: Low smoke, halogen free, flame retardant, thermoplastic, polyolefin-based compound (HM4 / SHF1) - HD 604. Color: Gray Production and Test Standards Construction...IEC / 353 Tests and Material...IEC / Flame Retardation...IEC / 1, IEC / 3 Cat A Halogen Content...IEC / 1-2 Smoke Density...IEC / 1-2 (DIN EN / 1-2) Working Temperature C / +90 C Min. Bending Radius (Fixed)...6 x Overall Diameter Rated Voltage / 1 kv Test Voltage kv Application Used as fixed installation cables in various electromechanical and electronic equipment of marine vehicles. Usable in all conditions of a marine environment such as dry, wet or oily locations. 2 (888)
3 Product Specifications M2XH Power and Control Cable Part # Sizes mm 2 Designation O.D. inches x 1.5 D x 2.5 D x 4 D x 6 D x 10 D x 16 D x 25 D x 1.5 T x 2.5 T x 4 T x 6 T x 10 T x 16 T x 25 T x 35 T x 50 T x 70 T x 95 T x 120 T x 150 T x 185 T x 240 T x 1.5 F x 2.5 F x 4 F x 6 F Part # Sizes mm 2 Designation O.D. inches x 10 F x 16 F x 25 F x 35 F x 50 F x 70 F x 95 F x 120 F x 150 F x 185 F x 1.5 M x 2.5 M x 4 M x 1.5 M x 2.5 M x 4 M x 1.5 M x 2.5 M x 2.5 M x 1.5 M x 2.5 M x 1.5 M x 2.5 M x 1.5 M x 2.5 M x 1.5 M summit.com/marine 3
4 Shielded Control Cable M2XCH Cable Structure 1 - Conductor: Electrolytic, stranded, annealed copper wire. IEC Class 5 (Class 2 and/or tinned on request). 2 - Insulation: Low smoke, halogen free, cross linked, polyethylene compound (XLPE). 3 - Shield: Electrolytic, copper-braided shield (90% coverage). M2XCH (EMC) type is wrapped by a copper tape in addition to this shield (100% coverage). 4 - Outer Sheath: Low smoke, halogen free, flame retardant, thermoplastic, polyolefin-based compound (HM4 / SHF1) - HD 604. Color: Gray Production and Test Standards Construction... IEC / 353 Tests and Material... IEC / Flame Retardation... IEC / 1, IEC / 3 Cat A Halogen Content... IEC / 1-2 Smoke Density... IEC / 1-2 (DIN EN / 1-2) Shielding Effectiveness (for EMC type)... DIN EN Working Temperature C / +90 C Min. Bending Radius (Fixed)... 8 x Overall Diameter Rated Voltage / 1 kv Test Voltage kv Application Used as fixed installation cables in various electromechanical and electronic equipment of marine vehicles. Usable in all conditions of a marine environment such as dry, wet or oily locations. 4 (888)
5 Product Specifications M2XCH Shielded Control Cable Part # Sizes mm 2 Designation O.D. inches x 2.5 TS x 4 TS x 1.5 FS x 2.5 FS x 4 FS x 25 FS x 1.5 MS x 2.5 MS Part # Sizes mm 2 Designation O.D. inches x 2.5 MS x 1.5 MS x 2.5 MS x 1.5 MS x 1.5 MS x 2.5 MS x 1.5 MS x 2.5 MS x 1.5 MS summit.com/marine 5
6 VFD Cable M2XCH-VFD Cable Structure 1 - Conductor: Circular stranded annealed electrolytic copper conductor (Class 5 according to IEC 60228) 2 - Insulation: Low smoke, halogen free, cross linked, polyethylene compound (XLPE). 3 - Filler and Bedding: Halogen-free, flame-retardant, thermoplastic polyolefin-based compound in between the inner sheath and the insulation of the conductor. (HM4/SHF1 - according to IEC /360) 4 - Screen: CU/PETP tape (100% coverage). Electrolytic copper braided screen (90% coverage density). 5 - Outer Sheath: Halogen free, flame retardant, thermoplastic, polyolefin-based compound (HM4 / SHF1 - according to IEC /360) Production and Test Standards Construction... IEC & IEC /350 Conductor Material... IEC Insulation Material... IEC Sheath Material... IEC Flame Retardance... IEC Halogen-Free Properties... IEC & IEC Low-Smoke Emission... IEC & IEC Tests... IEC Choice & Installation... IEC Min. Bending Radius (Fixed)... 6 x Overall Diameter Min. Bending Radius (during installation)... 8 x Overall Diameter Application Used as fixed installation cables in various electromechanical and electronic equipment of marine vehicles. Usable in all conditions of a marine environment such as dry, wet or oily locations. 6 (888)
7 Product Specifications M2XCH-VFD VFD Cable Part # Sizes (mm 2 ) Designation O.D. (inches) x x6 T-26 VFD x x6 T-41 VFD 1.02 * 3 x x6 T-66 VFD x x10 T-106 VFD 1.31 * 3 x x16 T-133 VFD x x16 T-212 VFD 1.63 * 3 x x25 T-250 VFD 1.86 * 3 x x25 T-300 VFD 2.02 * 3 x x35 T-400 VFD 2.16 * 3 x x50 T-500 VFD 2.41 *Available upon request. Contact Summit s Marine Division at (888) for more details. summit.com/marine 7
8 Overall Shielded Instrumentation Cable FM2XAH Cable Structure 1 - Conductor: Electrolytic, stranded, annealed copper wire. IEC Class 5 (Class 2 and/or tinned on request). 2 - Insulation: Low smoke, halogen free, cross linked, polyethylene compound (XLPE). Layup: Cores laid up in pairs; pairs laid up concentrically. 3 - Separator: Separating foil below shield. 4 - Drain Wire: Electrolytic, tinned, stranded, copper drain wire below shield. 5 - Shield: Aluminum tape shield (100% coverage). 6 - Separator: Separating foil above shield. 7 - Outer Sheath: Low smoke, halogen free, flame retardant, thermoplastic, polyolefin-based compound (HM4 / SHF1) - HD 604. Color: Gray Production and Test Standards 6 5 Construction... IEC / Tests and Material... IEC / Flame Retardation... IEC / 1, IEC / 3 Cat A Halogen Content... IEC / 1-2 Smoke Density... IEC / 1-2 (DIN EN / 1-2) Working Temperature C / +90 C Min. Bending Radius (Fixed)... 8 x Overall Diameter Rated Voltage / 250 V Test Voltage kv Application Used as control and communication cables in radio, radar and information systems for marine applications. Enables proper transmission of high frequency signals while minimizing environmental electromagnetic interference. Usable in all conditions in marine environment such as dry, wet or oily locations, and inside engine rooms (888)
9 Product Specifications FM2XAH Overall Shielded Instrumentation Cable Part # Sizes mm2 Designation O.D. inches x 2 x 1.5 TPS16-1P x 2 x.75 TPS18-1P x 2 x.50 TPS20-1P 0.28 Part # Sizes mm2 Designation O.D. inches x 2 x 2.5 TPS x 3 x 1.5 TTS x 3 x 2.5 TTS summit.com/marine 9
10 Individually and Overall Shielded Instrumentation Cable FM2XAAH Cable Structure 1 - Conductor: Electrolytic, stranded, annealed copper wire. IEC Class 5 (Class 2 and/or tinned on request). 2- Insulation: Low smoke, halogen free, cross linked, polyethylene compound (XLPE). Layup: Cores laid up in pairs/triads; pairs/triads laid up concentrically. 3 - Separator: Separating foil over pairs/triads 4 - Drain Wire: Electrolytic, tinned, stranded, copper drain wire along each pair/triad. 5 - Individual Shield: Aluminum tape shield over each pair/triad and drain-wire bunch (100% coverage). 6 - Separator: Separating foil above shield or inner sheath (on request). 7 - Drain Wire: Electrolytic, tinned, stranded, copper drain wire below overall shield. 8 - Overall Shield: Aluminum tape overall shield (100% coverage). 9 - Separator: Separating foil over overall shield. 10 -Outer Sheath: Low smoke, halogen free, flame retardant, thermoplastic, polyolefin-based compound (HM4/SHF1) HD 604. Color: Gray Production and Test Standards Construction... IEC / 376 Tests And Material... IEC / Flame Retardation... IEC / 1, IEC / 3 Cat A Halogen Content... IEC / 1-2 Smoke Density... IEC / 1-2 (DIN EN / 1-2) Working Temperature C / +90 C Min. Bending Radius (Fixed) x Overall Diameter Rated Voltage... 60/250 V Test Voltage kv Application Used as control and communication cables in radio, radar and information systems for marine applications. Enables proper transmission of high frequency signals while minimizing environmental electromagnetic interference. Usable in all conditions in marine environment such as dry, wet or oily locations, and inside engine rooms. 10 (888)
11 Product Specifications FM2XAAH Overall Shielded Instrumentation Cable Part # Sizes mm 2 Designation O.D. in inches x 2 x 2.5 TPS14-2P x 2 x 1.5 TPS16-2P x 2 x.75 TPS18-2P x 2 x.50 TPS20-2P x 2 x 1.5 TPS16-4P x 2 x.75 TPS18-4P x 2 x.50 TPS20-4P x 2 x.75 TPS18-5P x 2 x 1.5 TSP16-6P x 2 x.75 TPS18-6P 0.70 Part # Sizes mm 2 Designation O.D. in inches x 2 x.50 TPS20-6P x 2 x 1.5 TPS16-7P x 2 x 2.5 TPS14-7P x 2 x 1.5 TPS16-10P x 2 x.75 TPS18-10P x 2 x.50 TPS20-10P x 2 x 1.5 TPS16-12P x 2 x 1.5 TPS16-14P x 2 x.75 TPS18-15P x 2 x 1.5 TPS16-15P 1.10 summit.com/marine 11
12 Single Insulated Conductor Cable M2X Cable Structure 1 - Conductor: Electrolytic, stranded, annealed copper wire IEC Class 5 (Class 2 and/or tinned on request). 2 - Insulation: Low smoke, halogen free, flame retardant, cross linked, polyolefin compound (HF90). Color: Black (other colors available on request). Double insulation is available on request. 2 1 Production and Test Standards Construction...IEC / 353 Tests And Material...IEC / Flame Retardation...IEC / 1, IEC / 3 Cat A Halogen Content...IEC / 1-2 Smoke Density...IEC / 1-2 (DIN EN / 1-2) Working Temperature C / +90 C Min. Bending Radius (Fixed)...4 x Overall Diameter Rated Voltage / 1 kv Test Voltage kv Application Used as fixed installation cables in various electromechanical and electronic equipment, including marine switchboards. Usable in all conditions in marine environment, such as dry, wet or oily locations. 12 (888)
13 Product Specifications M2X Single Insulated Conductor Cable Part # Sizes (mm 2 ) Designation O.D. (inches) * 1 x 0.50 S * 1 x 0.75 S * 1 x 1.5 S * 1 x 2.5 S * 1 x 4 S x 6 S * 1 x 10 S x 16 S x 25 S Part # Sizes (mm 2 ) Designation O.D. (inches) x 35 S x 50 S x 70 S x 95 S x 120 S x 150 S x 185 S * 1 x 240 S *Available upon request. Contact Summit s Marine Division at (888) for more details. summit.com/marine 13
14 Fire Resistant and Flame Retardant Instrumentation and Telecommunication Cable BU(I) (NEK 606 S13) RED Cable Structure 1 - Conductor: Electrolytic, stranded, tinned copper wire. IEC Class Insulation: Halogen free EPR or halogen free HEPR. (All cable to be IEEE-45 color code.) 3 - Separator: Mica tape over conductor 4 - Lay Up: Cores laid up in pair, pairs laid up concentrically 5 - Drain Wire: Electrolytic, stranded, tinned copper drain wire along with every pair/triad. 6 - Screen: Electrolytic copper-backed polyester tape screen (100% coverage) over every pair/triad and drain wire 7 - Outer Sheath: SHF2 (SHF MUD on request). Color: Red Production and Test Standards Construction...NEK 606 S13, IEC / 376 Tests And Material...IEC / Flame Retardation...IEC / 1, IEC / 3 Cat A Fire Resistance...IEC Halogen Content...IEC / 1-2 Smoke Density...IEC / 1-2 (DIN EN / 1-2) Working Temperature C / +90 C Min. Bending Radius (Fixed)...8x Overall Diameter Rated Voltage V Test Voltage kv Application Used as fixed installation cables in various electromechanical and electronic equipments, emergency and critical systems as well as electric distribution and lightning systems. 14 (888)
15 Product Specifications BU(I) (NEK 606 S13) RED Fire Resistant, Flame Retardant Instrumentation and Telecommunications Cable Part # Sizes (mm 2 ) Designation O.D. in inches x 2x 1.5 BU TPS x 2 x 1.5 BU TPS summit.com/marine 15
16 Fire Resistant and Flame Retardant Power Cable BU (NEK 606 P17) RED Cable Structure 1 - Conductor: -Conductor: Electrolytic, stranded, tinned copper wire. IEC Class Insulation: Halogen free EPR. (All cable to be IEEE-45 color code.) 3 - Separator: Mica tape over conductor 4 - Outer Sheath: SHF2. Color: Red Production and Test Standards Construction...NEK 606 P17, IEC / 353 Tests and Material...IEC / Flame Retardation...IEC / 1, IEC / 3 Cat A Fire Resistance...IEC Halogen Content...IEC / 1-2 Smoke Density...IEC / 1-2 (DIN EN / 1-2) Working Temperature C / +90 C Min. Bending Radius (Fixed)...7x Overall Diameter Rated Voltage...0.6/1 kv Test Voltage kv Application Used as fixed installation cables in various electromechanical and electronic equipments, emergency and critical systems as well as electric distribution and lightning systems. 16 (888)
17 Product Specifications BU (NEK 606 P17) Fire Resistant and Flame Retardant Power Cable Part # Sizes (mm 2 ) Designation O.D. (inches) x 1.5 BU 16/7C x 1.5 BU 16/19C x 2.5 BU 14/3C x 2.5 BU 14/4C x 2.5 BU 14/7C 0.66 Part # Sizes (mm 2 ) Designation O.D. (inches) x 2.5 BU 14/10C x 6 BU 10/2C x 6 BU 10/3C x 16 BU 6/4C x 25 BU 4/4C 0.93 summit.com/marine 17
18 Fire Resistant Instrumentation and Telecommunication Cable BFOU(I) (NEK 606 S3/S7) Cable Structure 1 - Conductor: -Electrolytic, stranded, tinned copper wire IEC Class 2 (Class 5 on request). 2 - Separator: Mica tape over conductor 3 - Insulation: Halogen free EPR or Halogen free HEPR 4 - Layup: Cores laid up in pairs/triads, pairs/triads laid up concentrically. 5 - Drain Wire: Electrolytic, stranded, tinned copper drain wire along witp every pair/triad 6 - Screen: Electrolytic copper backed polyester tape screen (100% coverage) over every pair/triad and drain wire. 7 - Bedding: Halogen free compound. 8 - Screen: Electrolytic, tinned copper braided screen ( 90% coverage ). 9 - Outer Sheath: SHF MUD Production and Test Standards Construction...NEK 606 S3/S7, IEC 60092/376 Tests And Material...IEC / Flame Retardation...IEC /1, IEC / 3 Cat A Fire Resistance...IEC Halogen Content...IEC / 1-2 Smoke Density...IEC / 1-2 ( DIN EN 50268/1-2) Mud Resistance...IEC / 359 Working Temperature C / +90 C Min. Bending Radius (Fixed)...10 x Overall Diameter Rated Voltage...250V Test Voltage kv Application Fixed installation cable for signal and communication. 18 (888)
19 Product Specifications BFOU(I) (NEK 606 S3/S7) Fire Resistant and Flame Retardant Power Cable Part # Sizes (mm 2 ) Designation O.D. (inches) x 2 x /1PR x 2 x /2PR x 2 x /4PR x 2 x /1PR x 2 x /2PR x 2 x /4PR x 2 x /7PR 1.05 Part # Sizes (mm 2 ) Designation O.D. (inches) x 2 x /12PR x 2 x 1 17/18PR x 2 x 1 17/1PR x 2 x /1PR x 2 x /6PR x 2 x /8PR 1.29 summit.com/marine 19
20 Fire Resistant, Flame Retardant, Mud Resistant Power Cable BFOU (NEK 606 P5/P12) Cable Structure 1 - Conductor: -Electrolytic, stranded, tinned copper wire IEC Class 2 (Class 5 on request). 2 - Separator: Mica tape over conductor 3 - Insulation: Halogen free EPR or Halogen free HEPR 4 - Bedding: Halogen free compound. 5 - Screen: Electrolytic, tinned copper braided screen ( 90% coverage ). 6 - Outer Sheath: SHF MUD Production and Test Standards Construction...NEK 606 P5/P12, IEC 60092/353 Tests And MateriaL...IEC / Flame Retardation...IEC /1, IEC / 3 Cat A Fire Resistance...IEC Halogen Content...IEC / 1-2 Smoke Density...IEC / 1-2 ( DIN EN 50268/1-2) Mud Resistance...IEC / 359 Working Temperature C / +90 C Min. Bending Radius (Fixed)...8 x Overall Diameter Rated Voltage...0.6/1kV Test Voltage kv Application Used as fixed installation cables in various electromechanical and electronic equipment, emergency and critical systems as well as electric distribution and lighting systems. 20 (888)
21 Product Specifications BFOU (NEK 606 P5/P12) Fire Resistant, Flame Retardant, Mud Resistant Power Cable Part # Sizes (mm 2 ) Designation O.D. (inches) x /2C x 4 12/2C x 6 10/2C x 10 8/2C x 50 1/0-2C x /3C x /3C x 4 12/3C x 6 10/3C x 10 8/3C 0.81 Part # Sizes (mm 2 ) Designation O.D. (inches) x 16 6/3C x 25 4/3C x 35 2/3C x /4C x 4 12/4C x /7C x /7C x /10C x /16C x /20C 1.21 summit.com/marine 21
22 Index of Manufacturers In addition to wire and cable, Summit s Marine Division offers a full array of marine electrical products. Audio/Visual Signals Sirens/Bells/Horns/ SignalLights Federal Signal Ballasts Fluorescent/HID Universal Lighting Technologies Banding 316 SS Banding/Buckles Hayata Coated 316 SS Banding/ Buckles Hayata Batteries Industrial AAA/AA/C/D/ Trans/Lantern Rayovac Shipboard Battery Systems / Flooded and Gel Cell Interstate Batteries Cable Glands Marine/Industrial General Duty Gland CMP Hawke Marine / Industrial Class 1, Division 1 & 2 Gland CMP Hawke Cable Termination 250V / 600V / High Voltage Panduit Raychem Thomas & Betts Cable Tray Steel/Aluminum/Marine Rung B-Line by Eaton Niedax Fiberglass Ladder Chalfant Cables / Industrial MV 90/IAC/CLX/Control/ Instrumentation Okonite MV 90/IAC/Control/ Instrumentation/DLO Southwire MV 90/IAC/Control/ Instrumentation/Welding/ DLO AIW Control/Instrumentation/ Fiber Optic/IAC Belden Caulking Silicone GE Plastics USCG Approved Fire Stop Caulk Nelson Chemicals Wire Lube/Cleaners Ideal Lubricants/Cleaners/Solvents CRC Conduit Rigid Galvanized Steel LTV Shamrock Allied Rigid Stainless Steel Gibson Rigid Aluminum Easco Indalex Plastic Coated Plastibond Sealtight Anaconda Flexible Anaconda Conduit Fittings Malleable/Cast/Aluminum/ Steel Crouse-Hinds by Eaton Thomas & Betts Cast Alumimum Crouse-Hinds by Eaton Plastic Coated Plastibond Die Cast Steel Crouse-Hinds by Eaton Conduit Hubs Cast/Steel/Aluminum/SS Crouse-Hinds by Eaton/ Myers Cord Grips Aluminum Gland Type Grip Remke Nylon Gland Type Grip Kleinhuis (Niedax) Crane Control Crane Brake Parts Eaton (Cutler-Hammer) Distribution Gear Panel Boards/ Power Distribution Eaton (Cutler-Hammer) Westinghouse Military Spec. Navy Breakers/Shock & Vibration Eaton (Cutler-Hammer) Westinghouse Electricians Supplies Hand Tools Klein Tools Ideal Emergency Lighting Battery Operated Teledyne / Big Beam Chloride Dual Lite Excide Safety Systems Enclosures NEMA/Steel/Aluminum/SS Crouse-Hinds by Eaton Hoffman NEMA/Fiberglass Hoffman Flashlights Mini/D Cell/Lantern Rayovac Bright Star Fuses Glass/250V/600 V/ High Voltage Mersen European Fuses Mersen Grounding Systems Rods and Fittings Cadweld Heat Shrink Tubing Thick/Thin Wall Tubing Panduit 3M Raychem Industrial Lighting Fixtures Incandescent/Fluorescent/ HID Crouse-Hinds by Eaton Phoenix Fluorescent Mobern Industrial Reelites Electrical/Pneumatic Crouse-Hinds by Eaton Instruments Voltage/Amperes/Continuity Fluke Greenlee Labels/Markers/Signs Cable Marking/Safety Marking Panduit Hayata Weidmuller Lamps Incandescent/Fluorescent/ HID Sylvania Miniature Sunray Motor Control MCC/Enclosed Control Eaton (Cutler-Hammer) Westinghouse Military Spec. Navy Control/ Parts Eaton (Cutler-Hammer Navy) Navigation Light Panels USCG Approved Custom Panels J - Box Pin & Sleeve Plug & Receptacle Amp/Aluminum Crouse-Hinds by Eaton Amp/Nylon Stahl Portable Cord SO/SEOW/Type W/GGC Southwire Portable Cord Sets & Parts Cord Caps/Cord Sets Woodhead Hubbell Portable Lighting Hand Lamps/Class 1 Division 1/Non Hazard Woodhead Portable Cargo Lights Worklights Inc. Safety Switches Amp./General/ Heavy Duty Eaton (Cutler-Hammer) Shipboard Cable Hanger Commercial Cable Hanging Systems R. T. & D Kindorf Victor Commercial and Military Spec Systems R. T. & D Shipboard Communication Integrated Ship Communications Federal Signal Sound Powered Phones Hose McCann Shipboard General Alarm USCG/Navy Approved Brass Bells Hose McCann General Alarm Panels J-Box Shipboard Light Fixtures Incandescent/Fluorescent/ HID/Bronze/Aluminum/SS Phoenix Incandescent/Fluorescent/ HID/Aluminum/SS Aqua Signal L.C. Doane IRL Shipboard Navigation Lights USCG Approved/Single/ Dual Lamp Aqua Signal Shipboard Wiring Devices Switch/Receptacle/Junctions Phoenix Switch/Receptacle & Related Devices Eaton Strut Systems Slotted/Angled B-Line by Eaton Kindorf Tapes Insulating/Bonding/Color Coding 3M Terminal Blocks Din Rail Mount Weidmuller Terminal Tubes 1/2-4 Mil Spec. Nylon Dorn 1/2-4 Brass/Aluminum/ Male/Female Summit Electric Supply Terminals/Lugs Mechanical/Compression Panduit Burndy Thomas & Betts Timers Electronic/Mechanical Timers Tork Transformers Marine Duty Dry Type 25kVa - 500kVa Eaton (Cutler-Hammer) Westinghouse Dry Type and Oil Filled / SS Clad Olsun Oil Filled/SS Clad Van Tran Control Power Eaton (Cutler-Hammer) Machine Tool Acme Transformer Dry Type Distribution Acme Transformer Transit Barriers/MCTs Multi Diameter/Fire/Water/ Gas Rated Roxtec Tyraps Wire Securing Devices, Nylon & SS Panduit Hayata Thomas & Betts Wire Connectors Wire Nuts Ideal Wing Nuts 3M Wiring Devices Switches/Receptacles Cooper Wiring Devices Woodhead 22 (888)
23 CIrcular Mills AWG / / / / MCM MCM MCM MCM Rated Cross-Section at Metric Systems mm Equivalent Metric C.S.A. mm 2 U.S. Wire Gauge / / / / AWG or MCM AWG MCM summit.com/marine 23
24 The Industrial Marine Experts Low Smoke, Zero Halogen Marine Cable is In Stock Fires on board vessels can produce toxic gases and heavy smoke. Our marine low smoke, zero halogen (LSZH) cable can minimize the effects from these dangers. Save lives, protect your equipment from damage, and meet specifications that require use of LSZH cable. This cable is a low-cost alternative to the military spec cable often used in commercial applications. Ship-Set Quantities Available We stock a wide range of material to satisfy your immediate needs. Easy Identification Our low smoke, zero halogen cable is color coded to IEEE-45. Reduced Time and Labor Costs This ABS-approved cable offers flexible stranding and is easy to strip and terminate. In-house, custom cable armoring is available on request. Call for more information. Tested and Approved to IEC Standards This LSZH cable meets IEC standards for flame retardation, smoke density and halogen content. Top Construction Rating Cable construction is XLPE Insulation/SHF-1 Jacket. Get fast turn around and low minimums on non-stock items and special constructions. Marine Division 621 Time Saver Avenue Harahan, LA summit.com/marine Call Toll Free: (888) marine@summit.com
CIR CRUSH & IMPACT RESISTANT OIL & GAS CABLES
CIR CRUSH & IMPACT RESISTANT OIL & GAS CABLES Gexol CIR Crush and Impact Resistant Without External Armoring Passes the same stringent crush and impact testing required by UL 2225 for Type MC-HL Index
More informationCIR AG Power Cables. CIR AG Control Cable. CIR Type VFD Cable. CIR AG Ratings & Approvals. n UL Listed as Type TC-ER n UL Listed as TC-ER-HL (E123629)
Gexol CIR ARCTIC GRADE (AG) Crush and Impact Resistant Without External Armoring Passes the same stringent crush and impact testing required by UL 2225 for Type MC-HL n Shortest Lead Times Standard 8-10
More informationCIR CRUSH & IMPACT RESISTANT ARCTIC GRADE OIL & GAS CABLES
CIR CRUSH & IMPACT RESISTANT ARCTIC GRADE OIL & GAS CABLES Gexol CIR ARCTIC GRADE (AG) Crush and Impact Resistant Without External Armoring Passes the same stringent crush and impact testing required by
More informationCatalogue Telecommunication Cables INTRODUCCIÓN
Catalogue Telecommunication Cables INTRODUCCIÓN Conductores Tecnológicos S.A. www.contecsa.es Index of Cables Page Introduction 3 EAP / EAP-R 4 EAPSP / EAPSP-R 5 ISP / ICP 6 Conductores Tecnológicos S.A.
More informationCORFLEX. TYPE MC-HL & MV-105 or MC-HL OIL & GAS CABLES
CORFLEX TYPE MC-HL & MV-105 or MC-HL OIL & GAS CABLES INDEX Instrumentation Cables - Pairs and Triads (0V*)... 2 - The Original MC-HL Technology In 1958 Canada Wire and Cable, which s now part of Nexans,
More informationPower Cables. Introduction 3 RV 4 RVMV 5 RVSV 6 RVFV 7. ELECWIRES 2 Page
Power Cables Power Cables Page Introduction 3 RV 4 RVMV 5 RVSV 6 RVFV 7 ELECWIRES 2 www.elecwires.es INTRODUCTION Power Cables Power cables for electrical installations, domestic & industrial, specifically
More informationCatalogue Power Cables
Catalogue Power Cables Conductores Tecnológicos S.A. www.contecsa.es Index of Cables Page Introduction 13 RV 14 RVMV 15 RVSV 16 RVFV 17 Conductores Tecnológicos S.A. 2 www.contecsa.es INTRODUCTION Power
More informationCatalogue. Instrumentation & Control Cables
Catalogue Instrumentation & Control Cables Conductores Tecnológicos S.A. www.contecsa.es Index of Cables Page Introduction 3 Instrumentation VOV 4 VHOV 5 VOVMV 6 VHOVMV 7 Control RV 8 RZ1C3Z1 9 Conductores
More informationPRODUCT CATALOGUE Norröna
PRODUCT CATALOGUE Norröna WWW.SCANKAB.COM Table of contents MARINE AND OFFSHORE CABLES 1 TOXFREE XZ1-K (AS) - 0.6/1 kv 1 TOXFREE MARINE XO2TCuZ1-K (AS) - 150/250 V 5 4x2xAWG 24/1 CAT6 S/FTP LSZH-SHF1 -
More informationPHOTOVOLTAIC CABLES. Photovoltaic Cable 2000V/1500V Photovoltaic Cable 2000V/1000V
PHOTOVOLTAIC CABLES PHOTOVOLTAIC CABLES INDEX n AmerSol Dual-Certified (UL / ETL) Photovoltaic Cable 2000V/1500V....................... 2-3 n AmerSol Dual-Certified (UL / ETL) Photovoltaic Cable 2000V/1000V.......................
More informationFlexible Power Cable DLO
37-119 Flexible Power Cable DLO 2000 Volts 90 C Diesel Locomotive Cable Limited Smoke (Sizes 2/0 and higher) EP/CPE RHH, RHW-2 Flexible-stranded, tin-coated annealed copper Flame retardant, oil and sunlight
More informationDNVGL-CP-0401 Edition February 2016
CLASS PROGRAMME Type approval DNVGL-CP-0401 Edition February 2016 The electronic pdf version of this document, available free of charge from http://www.dnvgl.com, is the officially binding version. FOREWORD
More informationDNVGL-CP-0399 Edition March 2016
CLASS PROGRAMME Type approval DNVGL-CP-0399 Edition March 2016 The electronic pdf version of this document, available free of charge from http://www.dnvgl.com, is the officially binding version. FOREWORD
More informationShipboard & Offshore Cables
Shipboard & Offshore Cables Shipboard & Offshore Cables Páge Introduction 3 Power Cables XL / XL-FR 5 XC4L / XC4L-FR 6 XLC4L / XLC4L-FR 7 Instrumentation cables XHL / XHL-FR 8 XOL / XOL-FR 9 XHC4L / XHC4L-FR
More informationTelecommunication Cables
Telecommunication Cables Telecommunication Cables Introduction 3 EAP / EAP-R 4 EAPSP / EAPSP-R 5 ISP / ICP 6 Page ELECWIRES 2 www.elecwires.es INTRODUCCIÓN Telecommunication Cables Telephone cables suitable
More informationCORFLEX TYPE MC-HL POWER, CONTROL & INSTRUMENTATION CABLES
CORFLEX TYPE MC-HL POWER, CONTROL & INSTRUMENTATION CABLES CORFLEX TYPE MC-HL POWER, CONTROL & INSTRUMENTATION CABLES INDEX Corflex MC-HL Instrumentation - Pairs and Triads (0V*)... 1 - CORFLEX Cables
More informationINTRODUCTION. Our diverse range of world-class Specialty Insulated Wires and Cablesinclude: LV Cables -
MARINE CABLES Your Power Partner on the Seas INTRODUCTION We, a member of the Al-Bahja Group of Companies, are an ISO:900:2008 BASEC, UK certified integrated quality producer of LV and MV Cables, Wires&
More informationFlame Retardant Overall Screened Instrumentation Cables (multicore)
Flame Retardant Overall Screened Instrumentation Cables (multicore) RE-2X(St)H RE-2X(St)HSWAH LSZH Outer Sheath Tinned Copper Drain Wire LSZH Inner Sheath XLPE Insulation Plain Annealed Copper Aluminium/polyester
More informationCaledonian Flame Retardant Coaxial Cables
Caledonian Flame Retardant Coaxial Cables www.caledonian-cables.co.uk www.addison-cables.com Flame Retardant RG59 Coaxial cables LSZH Outer Sheath Tinned Copper Braid Aluminium+polyester/Aluminium Tape
More information1.1 Preferred Manufacturers are manufacturers of products that have worked well for the University on past projects.
DIVISION 26 (ELECTRICAL) PREFERRED MANUFACTURERS GENERAL INFORMATION 1.1 Preferred Manufacturers are manufacturers of products that have worked well for the University on past projects. 1.2 This list is
More informationOFFSHORE CABLES. Top Cable Central Headquarters. Leonardo Da Vinci, number Rubí (Barcelona) Spain
Top Cable Central Headquarters Leonardo Da Vinci, number 1 08191 Rubí (Barcelona) Spain OFFSHORE CABLES Tel +4 9 586 21 78 +4 9 586 21 68 Fax +4 9 586 21 65 sales@topcableoffshoremarine.com http://www.topcableoffshoremarine.com
More informationFlexflame. Arctic Grade Cables for Extreme Conditions. Photo: Sakhalin Energy Investement Company Ltd.
Flexflame Arctic Grade Cables for Extreme Conditions Photo: Sakhalin Energy Investement Company Ltd. Linking the future Draka Norsk Kabel is a part of Prysmian Group, a worldwide leader in the cable industry.
More informationPower Control Cable Iec
POWER CONTROL CABLE IEC 60502 1 PDF - Are you looking for power control cable iec 60502 1 Books? Now, you will be happy that at this time power control cable iec 60502 1 PDF is available at our online
More informationHigh Performance LSZH Fire Resistant Cable
High Performance LSZH Fire Resistant Cable www.cavicel.com 104/2 FIRECEL SR 114H is the long and well established CAVICEL fire resistant cable in the market, since many years. These cables are third party
More informationCaledonian Fire resistant Coaxial Cables
Caledonian Fire resistant Coaxial Cables www.caledonian-cables.net www.addison-cables.com Fire resistant rg59 b/u Coaxial Cables RG59 B/U FR LSZH Sheath Fire Resistant Tape Copper Clad Steel/Bare Copper
More informationCaledonian fire Resistant signal & Data cables
fire Resistant signal & Data cables www.addison-tech.com fire Resistant Rs485 Databus cables Copper Wire Braid(optional) Individual AL/Polyester Tape(optional) Mica Glass Tape+PE/PE+Silicone Rubber Insulation
More informationIEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission
ADDISON Flame Retardant CAT5e Data Cables FTX-CAT5e U/UTP4P24 FTX-CAT5e f/utp4p24 FTX-CAT5e sf/utp4p24 LSZH Outer Aluminium/Polyester Tape Solid Copper Conductor PE Insulation Tinned Copper Drain Wire
More informationNORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017
SECTION 26 0519 LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions
More information600/1000V XLPE Insulated, LSZH Sheathed, Double steel tape Armoured Power Cables (3 Cores)
Caledonian Flame Retardant Power & Control Cables www.caledonian-s.co.uk www.addison-s.com 600/1000V XLPE Insulated, LSZH Sheathed, Double steel tape Armoured Power Cables (3 Cores) FTX400 1RZ1MZ1-R (CU/XLPE/LSZH/DSTA/LSZH
More informationNote: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design.
ADDISON Flame Retardant RG59 B/U Coaxial cables Plain copper wire braid PE Solid Bare Copper PVC Outer Sheath APPLICATION The cables are designed for CCTV, security, smoke detection and evacuation monitoring
More informationIEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission
Flame Retardant RS485 Databus Cables Copper Wire Braid(optional) Individual AL/Polyester Tape(optional) Foam PE/Foam skin PE. Stranded Tinned Copper AL/Polyester Tape With Tinned Copper Drain Wire LSZH
More informationQUALITY THROUGH EXPERIENCE
QUALITY THROUGH EXPERIENCE Brief History of ÜNTEL Established in 1972 Partnership of Ünlü and Günan families since then 40 years of manufacturing experience with an extensive production range for various
More informationTitle: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards
Change History Date Description of Change Pages / Sections Modified Change Approver Initials 8/1/17 Updated section on Manufacturers 3 1. 6/15/16 Updated division section from 16120 to 26 05 00, - mgl44
More informationIEC UNE DESIGN. 1. Conductor. 2. Insulation. Cross-linked polyethylene (XLPE) 3. Outer sheath. Flexible PVC, black colour.
67 POWERFLEX RV-K POWERFLEX RV-K Industrial flexible cable for power transmission. 1 IEC 60502-1 - UNE 21123-2 DESIGN 1. Conductor 2 Electrolytic copper, class 5 (flexible), based on EN 60228 and IEC 60228.
More informationTotal Fire Solutions. Includes BS 8519 and the updated BS :
Total Fire Solutions Includes BS 8519 and the updated BS 5266-1:2011 www.aeicables.co.uk Introduction: Total Fire Solutions Power and control cable systems for life safety and fire-fighting applications
More information600/1000V SR Insulated Flexibles Control Cables (2-4 Cores & Multicores)
600/1000V SR Insulated Flexibles Control Cables (2-4 Cores & Multicores) FFX400 1SZ1-R(PH60)(CU/SR/LSZH 600/1000V Class 2) FFX400 1SZ1-F(PH60)(CU/SR/LSZH 600/1000V Class 5) Silicone Rubber Insulation Plain
More informationFIRE RESISTANT CABLES
Conducting Value The Last Cable Standing FIRE RESISTANT CABLES 100/7b ISO 9001:2008 Certificate No. CS1-249 MANAGEMENT SYSTEMS Assessed to ISO 9001:2008 Cert/LPCB ref. 217 GOST ISO 9001-2011 (ISO 9001:2008)
More informationPOINT OBSTRUCTION CONTROLLER POC TOUCHSCREEN CONTROLLERS
POINT OBSTRUCTION CONTROLLER Compliances: FAA Advisory Circular 70/7460-1L ICAO Annex 14, Volume I, Chapter 6 The controller provides the control and monitoring functions for an LED red obstruction lighting
More informationFlame Retardant EP/CPE POWER, CONTROL & INSTRUMENTATION CABLES
Flame Retardant EP/CPE POWER, CONTROL & INSTRUMENTATION CABLES 37-754 FLAME RETARDANT EP/CPE TYPE TC OR TC-ER POWER CABLE Two Five Conductor + Ground (Two, Three & Four Conductor) 600 V Rated 90 C Conductor*
More informationTYPE APPROVAL CERTIFICATE
TYPE APPROVAL CERTIFICATE Certificate No: TAE00000GG Revision No: 2 This is to certify: That the Data transmission cables and systems with type designation(s) MGD Cat 3, MGD Cat 5, Cat 5e, MGD cat 6, Cat
More informationAFIREFENIX SZ1-K 0,6/1 kv PH120 (AS+)
Page 1 / 7 Construction and tests. Standards: UNE 211025 Compliance with the Low Voltage Directive (LVD): 2014/35 / EU Construction Products Regulation (CPR) - Regulation (EU) Nº 305/2011: Reaction to
More informationCONNECTION SYSTEMS TRANSIT APPLICATIONS
CNNECTIN SYSTEMS TRANSIT APPLICATINS Ensure electrical and mechanical reliability with the engineered products and solutions of Shawcor s Connection Systems group INTEGRITY IS BEHIND EVERYTHING WE D. By
More informationBS /1000V XLPE Insulation LSZH Sheath Cables
BS 8573 600/1000V XLPE Insulation LSZH Sheath Cables Caledonian www.addison-cables.com Company Profile Caledonian & Addison, branded under Caledoniea & Addimax, established in 1978, offers one of the most
More informationUnion County Vocational - Technical Schools Scotch Plains, New Jersey
SECTION 220533 - HEAT TRACING FOR PLUMBING PIPING PART 1 - GENERAL 1.1 SUMMARY A. This Section includes plumbing piping heat tracing for freeze prevention, domestic hot-water-temperature maintenance, and
More informationADVANCE ELECTRICAL MEP CONTRACTING TRADING SERVICES
ADVANCE ELECTRICAL MEP CONTRACTING TRADING SERVICES ABOUT US Quality products, exceptional service and quick delivery of a diverse product line are the foundation of our company. By leveraging the portfolio
More information(Notices) EUROPEAN COMMISSION
14.8.2012 Official Journal of the European Union C 245/1 IV (Notices) NOTICES FROM EUROPEAN UNION INSTITUTIONS, BODIES, OFFICES AND AGENCIES EUROPEAN COMMISSION Commission communication in the framework
More informationTratos Railway Cables
January 2013 Tratos Railway Cables Cables for a moving world www.tratos.eu Introduction Tratos Cavi is a company specialising in the production of power, signalling, control and telecommunications cables
More informationCompact Module. Category 6A FTP Cabling System 1.1
Updated 24/09/12 Compact Module Cat 6A performance Suitable for 10-Gigabit Ethernet Ultra-slimline design Euro style module Interchangeable with other Euro Modules and blanks Individually QA tested Easy
More informationSECTION LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES
SECTION 26 05 19 - LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions
More informationIDENTIFYING TRAY CABLES FOR YOUR NEXT INSTALLATION A WHITE PAPER
IDENTIFYING TRAY CABLES FOR YOUR NEXT INSTALLATION A WHITE PAPER Published 3/23/2012 T hough rapidly increasing in popularity, tray cables are still a point of confusion for many. While the term tray cable
More informationSAS Security and Alarm Safety Cables
CABLES Security and Alarm Safety Cables Security and Alarm Safety Cables LOW SMOKE ZERO HALOGEN The right range of cables for modern building installations e-catalogue 203/4 Flexible solutions for commercial,
More informationSECTION ELECTRICAL GENERAL PROVISIONS
PART 1 GENERAL 1.01 SECTION INCLUDES A. General provisions for Electrical Systems B. Wire and cable for 600 volts and less. C. Wiring connectors. D. Electrical tape. E. Heat shrink tubing. F. Wire pulling
More informationWire and Cable. For more information on these Tyco Electronics products, visit the following website:
26 Wire and Cable Raychem High Performance Wire and Cable....26-2 to 26-4 Madison Cable Products...................26-5 to 26-7 Reference the following cables in Section 15 of this catalog: Premises Networking
More informationfire resistant cables
Building Technology fire resistant cables Special electrical and optical cables www.tecnikabel.com Special electrical and optical cables 2 INTRODUCTION Structured cabling solutions. Tecnikabel can provide
More informationCorra/Clad MC Cable The contractors cable of choice in place of conduit and wire.
Corra/Clad MC Cable The contractors cable of choice in place of conduit and wire. Installs fast and easy Lowers labor costs Replaces conduit and wire Provides superior grounding UL Listed Corra/Clad MC
More informationWires, Cables, Cords and Adhesive Tapes
702-CRC-006-E Revision: 08 Page: 1/34 Elaborated by: Douglas Ferreira Checked by: Nelson A. Coelho Approved by: Arnaldo Barbulio Filho Approval date: 23\08\13 1 OBJECTIVE This document presents the complementary
More informationThermocouple Cable TRANSMITTING, SENSING, MEASURING
Thermocouple Cable TRANSMITTING, SENSING, MEASURING Our Commitment Our commitment to our customers is simple - we deliver even when others can t. As one of Canada s largest wire, cable and data communication
More informationThe Quality Connection. BETAflam Fire Resistant Safety Cables
The Quality Connection BETAflam Fire Resistant Safety Cables BETAflam Contact Your personal customer number To offer you a more efficient service, we kindly ask you to mention your personal customer number
More informationDouble insulated, electron-beam cross-linked, halogen free photovoltaic wire sunlight resistant. Single conductor, flame retardant insulation.
Technical Data Sheet BETAflam Solar 125 flex UL 4703 Description Double insulated, electron-beam cross-linked, halogen free photovoltaic wire sunlight resistant. Single conductor, flame retardant insulation.
More informationOIL & GAS INDUSTRY OTHER INDUSTRIES
For ATEX Areas OIL & GAS INDUSTRY OTHER INDUSTRIES OIL & GAS INDUSTRY POTENTIALLY HAZARDOUS Class I GASES VAPORS LIQUIDS Petrosumsave Zone 0 An area in which an explosive mixture is continuously present,
More informationSensor and transducer cables
Sensor and transducer cables Special cables for industrial instrumentation Expertise in sensor cables Nexans has a great expertise in research and development of special and customized sensor cables for
More informationIEC NORMAS PUBLICADAS. As normas ISO/IEC já estão relacionadas em normas ISO Publicadas
IEC NORMAS PUBLICADAS As normas ISO/IEC já estão relacionadas em normas ISO Publicadas IEC/TC 1 - Terminology IEC 60050-161-am5 ed1.0 (2015-02) - Amendment 5 - International Electrotechnical Vocabulary
More information5. Identification products.
Essex County College - West Essex Campus Addition And Renovations dib # 54292 / 11-14 [SECTION 260523- CONTROL-VOLTAGE ELECTRICAL POWER CABLES PART 1- GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general
More informationDNVGL-CP-0402 Edition February 2016
CLASS PROGRAMME Type approval DNVGL-CP-0402 Edition February 2016 The electronic pdf version of this document, available free of charge from http://www.dnvgl.com, is the officially binding version. FOREWORD
More informationFIRE RESISTANT CABLES FP300
FIRE RESISTANT CABLES FP300 Fire resistant LSOH power cables for fixed wiring FIRE RESISTANT CABLES FP300 LPCB Ref No: 077e/01 FP300 > Prysmian FP300 is designed for cabling essential safety circuits associated
More information2016 CDM Smith All Rights Reserved July 2016 SECTION FIBER OPTIC DATA NETWORK
PART 1 GENERAL 1.01 SCOPE OF WORK SECTION 27 12 23 FIBER OPTIC DATA NETWORK A. Furnish, install, terminate, and test all fiber optic equipment and cabling necessary for a complete and functional data highway
More informationMASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 28 ELEC. SAFETY & SECURITY SECTION CONDUCTORS AND CABLES FOR ELECTRONIC SAFETY AND SECURITY
SECTION 280513 - CONDUCTORS AND CABLES FOR ELECTRONIC SAFETY AND SECURITY PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Coaxial cabling. 2. RS-232 cabling. 3. RS-485 cabling. 4. Low-voltage control
More informationTable of Contents. TELE-FONIKA KABLE SA (DMCC Branch). 4 TELE-FONIKA Kable Group 6 FLAME-X 950 SERIES 1 11 FLAME-X 950 SERIES 2
FLAME-X 950 TELE-FONIKA KABLE SA (DMCC Branch). Table of Contents is the Regional Middle East Sales Office of Tele-Fonika Kable S.A. from Poland, 4-th largest manufacturer of electric cables and wires
More informationComtran Cable. Hub-LINK Cables for Transit Applications
Comtran Cable Hub-LINK Cables for Transit Applications Overview Hub-LINK rail transit cables are designed to resist the rugged conditions of the underground and at-grade environments, including: Temperature
More informationPhotovoltaic Cables EN H1Z2Z2-K
Photovoltaic Cables EN 50618 H1Z2Z2-K COMPANY PROFILE Caledonian, established in 1978, offers one of the most complete lines of fiber and copper cabling system solutions with over hundreds of different
More informationHavells Fire Survival Cables
Fire Survival Cables Designed for Critical Installation of National Importance Airports / Thermal Power Plants Metro Rail Projects / Rail Terminals / Nuclear Interstate Bus Terminals / Installation Prone
More informationCABLES FOR ALARM AND SAFETY SYSTEMS
CABLES FOR ALARM AND SAFETY SYSTEMS 2 IT S ALL ABOUT RELIABILITY. It is always important to choose high quality cables, especially when it comes to alarms and safety systems. Even small and seemingly insignificant
More informationSAFE, FAST PROFESSIONAL WIRING SOLUTIONS STANDARDISED & INDIVIDUAL COMPLEX SMART SOLUTIONS. 25 years: You name it. We have it. DANNEWITZ GmbH & Co
SAFE, FAST PROFESSIONAL WIRING SOLUTIONS STANDARDISED & INDIVIDUAL COMPLEX SMART SOLUTIONS GmbH & Co 25 years: You name it. We have it. THOROUGHLY THOUGHT OUT SOLUTIONS We offer an extensive product range
More informationNorth American Cable Glands
North American Cable Glands INTRODUCTION Linking the future As the worldwide leader in the cable industry, Prysmian Group believes in the effective, efficient and sustainable supply of energy and information
More information600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (Multicore)
600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (Multicore) FGD400 1RV-R (CU/XLPE/PVC 600/1000V Class ) FGD400 1RVMV-R (CU/XLPE/PVC/SWA/PVC 600/1000V Class ) PVC Outer Sheath Plain Annealed
More informationLloyd s Register Type Approval System Test Specification Number 3
Working together for a safer world Lloyd s Register Type Approval System Test Specification Number 3 July 2015 Performance Test Specification for Equipment to be used in Marine Applications: Electric Cables
More informationSECTION LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES (600 VOLTS AND BELOW)
SECTION 26 05 21 PART 1 - GENERAL 1.1 DESCRIPTION This section specifies the furnishing, installation, and connection of the low voltage power and lighting wiring. 1.2 RELATED WORK A. Excavation and backfill
More informationAuthor Owner Issue Authority Name: Gordon MacKenzie Title: Senior Engineer Engineering Design and Standards
1. SCOPE This Specification details requirements for General Wiring cables up to and including 450/750V for use on lighting and general power wiring installations complying with BS 7671 but not forming
More informationBS FP600 achieves the maximum 120 minute rating under the BS test conditions, which is required for fire fighting applications.
FIRE RESISTANT CABLES FP600 FIRE RESISTANT CABLES FP600 BS7346-6 FP600 > Prysmian FP600 is a unique enhanced performance fire resistant power cable, designed specifically to meet the more onerous fire
More informationYour Partner for Custom Interconnectivity Solutions. ISO 9001:2008 AS9100C:2009 ISO 13485:2003 ISO 17025:2005 Qualified
Your Partner for Custom Interconnectivity Solutions ISO 9001:2008 AS9100C:2009 ISO 13485:2003 ISO 17025:2005 Qualified LEMO Precision Custom Connection Solutions The Original Push-Pull Connector Seven
More informationCORRIGENDA. (Publication of titles and references of harmonised standards under Union harmonisation legislation)
C 173/162 EN Official Journal of the European Union 13.5.2016 CORRIGENDA Corrigendum to Commission communication in the framework of the implementation of Directive 2006/95/EC of the European Parliament
More informationF1202 TRACE HEATING. Road & Ramp
Trace Heating Specialists Road & Ramp ROAD & RAMP HEATING ESH Trace Heating Ltd provide a comprehensive range of products to prevent the settlement of snow and formation of ice on roads, ramps and stairs.
More informationCaledonian. FIREFLIX ire Resistant Coaxial Cables
Caledonian FIREFLIX ire Resistant Coaxial Cables table OF COntents Fire resistant Coaxial Cables Fire Resistant RG59 B/U coaxial cables...25 Fire Resistant RG6 A/U coaxial cables...28 Fire Resistant RG6
More informationEnergy Division Heat-shrinkable joints for halogen-free, flame-retardant and fire-resistand cables up to 1 kv
Energy Division http://energy.tycoelectronics.com Heat-shrinkable joints for halogen-free, flame-retardant and fire-resistand cables up to 1 kv R Heat-shrinkable joints for halogen-free, flame-retardant
More informationFirecel Safety Cables
103/7 Firecel Safety Cables Low Smoke - Zero Halogen www.cavicel.com Firecel Safety Cables Low Smoke - Zero Halogen Over the last 30 years CAVICEL has developped a deep experience in studying, designing
More informationCablosam Tapes for Fire-Resistant Cables
Cablosam Tapes for Fire-Resistant Cables 2 Cablosam Tapes for Fire-Resistant Cables We Enable Energy As one of the oldest industrial companies in Switzerland, founded in 1803, we focus on products and
More information(Publication of titles and references of harmonised standards under Union harmonisation legislation) (Text with EEA relevance) (2017/C 298/02)
C 298/14 EN Official Journal of the European Union 8.9.2017 Commission communication in the framework of the implementation of Directive 2014/35/EU of the European Parliament and of the Council on the
More information13. UNITED KINGDOM Standards Supply Voltage and Plug Configurations 247
13. UNITED KINGDOM 13.1 Standards 13.1.1 BSI 240 13.1.2 BASEC 242 13.1.3 BBC 242 13.1.4 BNFL 242 13.1.5 BRB 242 13.1.6 British Telecom 243 13.1.7 Department of the Environment 243 13.1.8 Department for
More informationSTANDARDS INSTALLATION. Certificate No 077m
Certificate No 077m > Prysmian FP600 is a unique enhanced performance fire resistant power cable, designed specifically to meet the more onerous fire survival requirements now requested by regulators and
More informationEvolution of Cable Fire Safety Standards in Australia
Evolution of Cable Fire Safety Standards in Australia INTRODUCTION Fire safety standards for electrical cables have evolved over the past few decades to the extent that they are now well established along
More informationIntroduction.
Introduction The safety of occupants and users of public, commercial and industrial premises is of paramount importance. One important safety feature is the appropriate use of fire performance cables for
More informationROLLING STOCKS Cables ELECRAIL
3 ROLLING STOCKS Cables ELECRAIL 03/2016 SILICONE HF POLYOLEFIN HF POLYOLEFIN SLEEVES ELECRAIL ELECRAIL ELECRAIL ELECRAIL PHFLE 4 Plastelec Group has been designing, developing, manufacturing and marketing
More informationCable technology for highest safety requirements
Cable technology for highest safety requirements Daetwyler We are a provider of high-grade quality system solutions and services in the areas of structured data cabling, telecom carriers, safety cabling,
More informationSECTION CONDUCTORS AND CABLES FOR ELECTRONIC SAFETY AND SECURITY
SECTION 280513 CONDUCTORS AND CABLES FOR ELECTRONIC SAFETY AND SECURITY PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions
More informationLV FIRE RESISTANT CABLES
LV FIRE RESISTANT CABLES CONTENTS 3 GENERAL INTRODUCTION LV FIRE RESISTANT CABLES TECHNICAL INFORMATION 4 9 12 24 26 GENERAL CABLE STRUCTURE ELECTRICAL CHARACTERISTICS CURRENT RATING VOLTAGE DROP SHORT
More informationMEDIUM, LOW AND CONTROL VOLTAGE CABLES
Related Sections U-M Design Guideline Sections: 260800 - Electrical Acceptance Tests Products Medium Voltage Primary Cables Primary power distribution cable shall be single conductor stranded copper, with
More informationINTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 60092-350 Second edition 2001-06 Electrical installations in ships Part 350: Shipboard power cables General construction and test requirements Installations électriques à bord
More informationAFUMEX LSX LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS:
PRODUCT DATASHEET & APPLICATIONS GUIDE LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 KEY BENEFITS: BASEC approved for the full size range of BS8436 (1.0mm 2 to 2.5mm 2 ) Additionally tested for
More informationPressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications
Force Pressure Temperature Switch Pressure sensors Ex ia I / IIC T6 acc. to ATEX with internal diaphragm with front flush diaphragm Accuracy: 0,25% and 0,5 % Standard output: 4...20 ma; 2-wire system Description
More informationSchedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK
ISO/IEC 17065:2012 to provide product conformity certification Presley Way Crownhill Milton Keynes MK8 0ES Contact: Tracie Hunter Tel: +44 (0)1908 267300 Fax: +44 (0)1908 267255 E-Mail: mail@basec.org.uk
More information