UV RESISTANT ACCORDING TO HD 605 RULE

Size: px
Start display at page:

Download "UV RESISTANT ACCORDING TO HD 605 RULE"

Transcription

1 UV RESISTANT ACCORDING TO HD 605 RULE Faced with increasingly frequent requirements to install outdoor wiring for data and signals, we further developed a special range of cables called: BLUE TOP LINE for outdoor installations These cables are designed and constructed with a special sheath suitable for outdoor and underground installation. It follows that the best mechanical strength of the sheath allows these cables: longer life if subjected to aggression particularly intense weathering (sun, rain, humidity) according to EN 50396, HD S2 and HD 605 rules longer duration in case of laying underground (flooding of wells) greater capacity for absorption of thermal shock (winter, summer) greater stability over time of signals and data transmission capacity ability to coexist in the same conduits for wires and cables for power signals Fabbrica Trentina Conduttori s.r.l Z.I. Pineta Via Pineta 21/B Rovereto ( TN ) - Italy - Tel Fax info@fctsecuritycables.com -

2 UTP-FTP BLUE Cables for transmitting voice and data at high speeds (up to 100 Mbit / s) used in structured cabling. TYPE / DESCRIPTION FTP 4x2xAWG24/1 cat. 5 E BLU UTP 4x2xAWG24/1 cat. 5 E BLU FTP 4x2xAWG23/1 cat. 6 BLU UTP 4x2xAWG23/1 cat. 6 BLU FTP 4x2xAWG24/1 cat. 5 E ARMOURING UTP 4x2xAWG24/1 cat. 5 E ARMOURING FTP 4x2xAWG23/1 cat. 6 ARMOURING UTP 4x2xAWG23/1 cat. 6 ARMOURING 04/2010 ALLARM GR.4 BLUE Cables for fire and burglar alarms. The sheath has a resistance up to 3000 V. These cables can be installed in conduit with usual cables 220/380 V. TYPE / DESCRIPTION ALA 4x0,22 GR. 4 ALA 6x0,22 GR. 4 ALA 8x0,22 GR. 4 ALA 10x0,22 GR. 4 ALA 2x0,50+2x0,22 GR. 4 ALA 2x0,50+4x0,22 GR. 4 ALA 2x0,50+6x0,22 GR. 4 ALA 2x0,50+8x0,22 GR. 4 ALA 2x0,75+2x0,22 GR. 4 ALA 2x0,75+4x0,22 GR. 4 ALA 2x0,75+6x0,22 GR. 4 ALA 2x0,75+8x0,22 GR. 4 RG.. 0,6/1 kv BLUE Cables for RF transmission and reception of video signals for closed-circuit TV systems. TYPE / DESCRIPTION RG 59 BLUE GR.4 0,6/1 kv RG 58 BLUE GR.4 0,6/1 kv RG 11 BLUE GR.4 0,6/1 kv TVCC BLUE Cables for external cameras and monitors. TYPE / DESCRIPTION MINI RG x 1,5 BLUE MINI RG x 0, x 0,22 BLUE MINI RG x x 0,50 BLUE MINI RG x 0, x 0,22 BLUE MINI COAX + 2 x 0, x 0,22 BLUE MINI RG x 0,75 BLUE MINI RG x 0,22 BLUE RG x 0,75 BLUE RG x 0, x 0,22 BLUE LIYCY 450/650 V BLUE Cables to signal and control. TYPE / DESCRIPTION LIYCY 450/650 V 2x0,50 LIYCY 450/650 V 3x0,50 LIYCY 450/650 V 4x0,50 LIYCY 450/650 V 5x0,50 LIYCY 450/650 V 6x0,50 LIYCY 450/650 V 7x0,50 LIYCY 450/650 V 8x0,50 LIYCY 450/650 V 10x0,50 LIYCY 450/650 V 12x0,50 LIYCY 450/650 V 2x0,75 LIYCY 450/650 V 3x0,75 LIYCY 450/650 V 4x0,75 LIYCY 450/650 V 5x0,75 LIYCY 450/650 V 6x0,75 TYPE / DESCRIPTION LIYCY 450/650 V 8x0,75 LIYCY 450/650 V 10x0,75 LIYCY 450/650 V 12x0,75 LIYCY 450/650 V 2x2x0,50 LIYCY 450/650 V 2x2x0,50 LIYCY 450/650 V 3x2x0,50 LIYCY 450/650 V 4x2x0,50 LIYCY 450/650 V 6x2x0,50 LIYCY 450/650 V 2x2x0,75 LIYCY 450/650 V 2x2x0,75 LIYCY 450/650 V 3x2x0,75 LIYCY 450/650 V 4x2x0,75 LIYCY 450/650 V 6x2x0,75 J-Y(st)Y BLUE TYPE / DESCRIPTION J-Y(ST)Y 1x2x0,80 J-Y(ST)Y 2x2x0,80 Bus cables.

3 Fire Resistant Cables

4 EUROSAFE SCREENED 300/500 V Power cables and control and signaling, shielded aluminum/polyester flame retardant, halogen free and fire resistant Conductor 2. Insulation 3. Assembling 4. Drain wire 5. Al/Pet tape 6. Outer sheath APPLICATION: Suitable for the transport of energy and signal transmission and electrical controls for when you need maximum security against fire, such as emergency lighting and alarm systems, automatic fire detection, fire extinguishing devices, automatic door opening, ventilation systems and air conditioning, emergency telephone systems. INSTALLATION: For fixed installation, normal or wet environments inside and outside temporarily. They can be installed on platforms, pipes, conduits and similar systems. FEATURES DESCRIPTION RULES Conductors: bare copper cl. 1 CEI EN (Tab 9) Insulation: ceramizable silicon rubber Cores colour code: CEI UNEL Assembling: polyester tape Drain wire: tinned copper 1x0,6 mm Shield: Al/Pet tape thickness 9/23 µm covering > 110% Outer sheath: LSZH compound M1 Type CEI CEI EN Sheath colour code: red RAL 3000 Fire retardant: IEC Flame retardant: CEI EN Halogen free: (< 0,5 mg/g - 0,5%) CEI EN /2 - IEC /2 Reduced smoke emissions: (transmittance>60%) CEI EN Fire resistant: during 120 min. at 830 C C CEI EN Fire resistant: BS 6387 cat. CWZ Electric resistance: according to CEI EN (Tab 9) Rated voltage Uo/U: 300/500 V Max voltage: 550 V Testing voltage: 2 kv Max working temperature: 90 C Max conductor temperature: 180 C Short circuit temperature: 350 C Min installation temperature: 0 C Bending radius: Ø x 8 Outer printing: FTC / BERICA CAVI S.P.A. (VI) EUROSAFE Nr cores x Sect. mmq SHIELDED 300/500 V BS 6387 CWZ CEI EN PH(120) IEC CE Year/Lot EMI n x mm 2 mm kg/km n x mm 2 mm kg/km 02 2x0,50 5,3 36 2X0,75 6,1 49 3x0,75 6,7 65 4x0,75 7,2 79 6x0,75 8, x1 6,7 58 3x1 7,1 74 4x1 7,7 91 2x1,5 8,1 82 3x1,5 8, x1,5 9, x1,5 10, x2,5 8, x2,5 9, x2,5 10, x2,5 11,3 217 For more information

5 EUROSAFE UNSCREENED 300/500 V Power cables and control and signaling, fire-retardant, halogen free and fire resistant 1. Conductor 2. Isnsulation 3. Outer sheath APPLICATION: Suitable for the transport of energy and signal transmission and electrical controls for when you need maximum security against fire, such as emergency lighting and alarm systems, automatic fire detection, fire extinguishing devices, automatic door opening, ventilation systems and air conditioning, emergency telephone systems. INSTALLATION: For fixed installation, normal or wet environments inside and outside temporarily. They can be installed on platforms, pipes, conduits and similar systems. FEATURES DESCRIPTION RULES EMI Conductors: bare copper cl. 1 CEI EN (Tab 9) Insulation: ceramizable silicon rubber Cores colour code: CEI UNEL Outer sheath: LSZH compound M1 Type CEI CEI EN Sheath colour code: red RAL 3000 Fire retardant: IEC Flame retardant: CEI EN Halogen free: (< 0,5 mg/g - 0,5%) CEI EN /2 - IEC /2 Reduced smoke emissions: (transmittance >60%) CEI EN Fire resistant: during 120 min. at 830 C C CEI EN Fire resistant: BS 6387 cat. CWZ Electric resistance: according to CEI EN (Tab 9) Rated voltage Uo/U: 300/500 V Max voltage: 550 V Testing voltage: 2 kv Max working temeprature: 90 C Conductor max temeprature: 180 C Short circuit temeprature: 350 C Min installation temperature: 0 C Bending radius: Ø x 8 Outer sheath: FTC / BERICA CAVI S.P.A. (VI) EUROSAFE Nr cores x Sect mmq UNSHIELDED 300/500 V BS 6387 CWZ CEI EN PH(120) IEC CE Year/Lot n x mm 2 mm kg/km n x mm 2 mm kg/km For more information 2x0,50 5,2 32 2X0,75 6,0 44 3x0,75 6,6 60 4x0,75 7,1 74 2x1 6,6 54 3x1 7,0 70 4x1 7,6 87 2x1,5 8,0 78 3x1,5 8, x1,5 9, x1,5 10, x2,5 8, x2,5 9, x2,5 10, x2,5 11,

6 EUROSAFE JE-H(St)H 300/500 V Power cables and control and signaling, shielded aluminum/polyester flame retardant, halogen free and fire resistant Conductor 2. Insulation 3. Flame protection 4. Drain wire 5. Al/Pet tape 6. Outer sheath APPLICATION: Suitable for the transport of energy and signal transmission and electrical controls for when you need maximum security against fire, such as emergency lighting and alarm systems, automatic fire detection, fire extinguishing devices, automatic door opening, ventilation systems and air conditioning, emergency telephone systems. INSTALLATION: For fixed installation, normal or wet environments inside and outside temporarily. They can be installed on platforms, pipes, conduits and similar systems. FEATURES DESCRIPTION RULES Conductors: bare copper cl. 1 CEI EN (Tab 9) Insulation: ceramizable silicon rubber Cores colour: (blue-red) - (yellow-grey) - (green-brown) - (white-black) DIN VDE 815 Flame protection: glass-fibre tape thichness 0,12 mm Drain wire: tinned copper 1x0,6 mm Shield: Al/Pet tape thickness 9/23 µm covering > 110% Outer sheath: LSZH compound M1 Type CEI CEI EN Sheath colour code: red RAL 3000 Fire retardant: CEI EN cat. C Flame retardant: CEI EN Halogen free: (< 0,5 mg/g - 0,5%) CEI EN /2 - IEC /2 Reduced smoke emissions: (trasmittance >60%) CEI EN Fire resistant: during 120 min. at 830 C C CEI EN Fire resistant: DIN VDE Fire resistant: during 180 min. at 750 C (FE180) IEC VDE Electric resistance: according to CEI EN (Tab 9) Rated voltage Uo/U: 300/500 V Max voltage: 550 V Testing voltage: 2 kv Working max temperature: 90 C Cunductor max temperature: 180 C Short-circuit temperature: 350 C Min. installation temperature: 0 C Bending radius: Ø x 10 Outer printing: FCT / BERICA CAVI S.P.A. (VI) EUROSAFE JE-H(St)H Nr cores x Ø cond. E30/E60 DIN CEI EN PH(120) CE Year/Lot EMI n x Ø mm kg/km 1x2x0,80 5,8 40 2x2x0,80 8,8 77 3x2x0,80 9,4 97 4x2x0,80 11, x2x0,80 11, x2x0,80 12, x2x0,80 13,4 214 n x Ø mm kg/km 10x2x0,80 14, x2x0,80 16, x2x0,90 6,0 45 2x2x0,90 8,8 84 6x2x0,90 12, x2x0,90 16,9 344 For more information 04

7 EUROSAFE FLEX 300/500 V Power cables and control and signaling, shielded aluminum/polyester flame retardant, halogen free and fire resistant 1. Conductor 2. Insulation 3. Assembling 4. Drain wire 5. Al/Pet tape 6. Outer sheath APPLICATION: Suitable for the transport of energy and signal transmission and electrical controls for when you need maximum security against fire, such as emergency lighting and alarm systems, automatic fire detection, fire extinguishing devices, automatic door opening, ventilation systems and air conditioning, emergency telephone systems. INSTALLATION: For fixed installation, normal or wet environments inside and outside temporarily. They can be installed on platforms, pipes, conduits and similar systems. FEATURES DESCRIPTION RULES Conductors: bare copper cl. 5 CEI EN (Tab 9) Insulation: ceramizable silicon rubber Cores colour code: CEI UNEL Assembling: polyester tape Drain wire: tinned copper 1x0,6 mm Shield: Al/Pet tape thickness 9/23 µm covering > 110% Outer sheath: LSZH compound M1 type CEI CEI EN Sheath colour code: red RAL 3000 Fire retardant: IEC Flame retardant: CEI EN Halogen free: (< 0,5 mg/g - 0,5%) CEI EN /2 - IEC /2 Reduced smoke emissions: (transmittance >60%) CEI EN Fire resistant: during 120 min. at 830 C C CEI EN Electric resistance: according to CEI EN (Tab 9) Rated voltage Uo/U: 300/500 V Max voltage: 550 V Testing voltage: 2 kv Max working temeprature: 90 C Conductor max temeprature: 180 C Short circuit temeprature: 350 C Min installation temperature: 0 C Bending radius: Ø x 8 Outer sheath: FTC / BERICA CAVI S.P.A. (VI) EUROSAFE FLEX Nr cores x Sect mmq UNSHIELDED 300/500 V CEI EN PH(120) IEC CE Year/Lot n x mm 2 mm kg/km n x mm 2 mm kg/km For more information 2x0,50 6,1 39 3x0,50 6,4 52 4x0,50 7,0 62 5x0,50 7,8 70 2x0,75 6,3 49 3x0,75 6,8 63 4x0,75 7,4 76 5x0,75 7,4 94 2x1 7,1 61 3x1 7,3 80 4x1 8,1 95 5x1 8, x1,5 8,0 83 3x1,5 8, x1,5 9, x1,5 10, x2,5 9,3 83 3x2,5 9, x2,5 10, x2,5 11,

8 EUROSAFE NBN 300/500 V Telephone cable, shielded aluminum/polyester flame retardant, halogen free and fire resistant Conductor 2. Insulation 3. Assembling 4. Drain wire 5. Al/Pet tape 6. Outer sheath APPLICATION: Suitable for the interconnection of telephone equipment when you need maximum security against fire. INSTALLATION: For fixed installation, normal or wet environments inside and outside temporarily. They can be installed on platforms, pipes, conduits and similar systems. FEATURES DESCRIPTION RULES Conductors: bare copper cl. 1 CEI EN (Tab 9) Insulation: ceramizable silicon rubber Cores colour code: numbered white and blue CEI UNEL Assembling: polyester tape Drain wire: tinned copper 1x0,6 mm Shield: Al/Pet tape thickness 9/23 µm covering > 110% Outer sheath: LSZH compound M1 type CEI CEI EN Sheath colour code: orange RAL 2003 Fire retardant: IEC Flame retardant: CEI EN Halogen free: (< 0,5 mg/g - 0,5%) CEI EN /2 - IEC /2 Reduced smoke emissions: (transmittance>60%) CEI EN Fire resistant: during 120 min. at 830 C C CEI EN Fire resistant: NBN NBN Electric resistance: according to Rated voltage Uo/U: 300/500 V Max voltage: 550 V Testing voltage: 2 kv Max working temperature: 90 C Max conductor temperature: 180 C Short circuit temperature: 350 C Min installation temperature: 0 C Bending radius: Ø x 8 Outer printing: FTC / BERICA CAVI S.P.A. (VI) EUROSAFE Nr cores x Ø 300/500 V NBN NBN RF 1,5U CEI EN PH(120) IEC CE Year/Lot n x Ø mm kg/km 1x2x0,9 6,0 45 2x2x0,9 8,5 83 3x2x0,9 9, x2x0,9 10, x2x0,9 11,7 171 n x Ø mm kg/km 6x2x0,9 12, x2x0,9 12, x2x0,9 15, x2x0,9 15,8 339 For more information 06

9 RG 59 B/U FR 75Ω LSZH Coaxial cables for video signal transmission, halogen free 1. Conductor 2. Insulation 3. Flame protection 4. Shield 5. Outer sheath APPLICATION: Suitable for the connection between camera and recorder in a closed circuit television systems when there is requirement to transmit the signal in the presence of a great fire. INSTALLATION: For fixed installation inside, without protection or pipes within sight, embedded or closed systems. FEATURES DESCRIPTION RULES Conductor: bare copper 0,65 mm Insulation: polyethylene Insulation: ceramizable silicon rubber Flame protection: glass tape Shield: double bare copper braid Outer sheath: LSZH Compound M1 type CEI CEI EN Sheath colour code: red RAL 3000 Flame retardant: CEI EN Halogens free: (< 0,5 mg/g - 0,5%) CEI EN /2 - IEC /2 Reduced smoke emmission: (transmittance > 60%) CEI EN Fire resistant: during 90 minutes at 830 C C CEI EN Testing voltage: 7 kvac Max working temeprature: 90 C Min. installation temperature: 0 C Bending radius: Ø x 14 Outer sheath: FTC / BERICA CAVI S.P.A. (VI) RG 59 B/U FR Year/Lot ATTENUATION MHz 0, db/100 m 0,7 1,1 2,6 3,6 14,3 31,6 mm kg/km RG 59 B/U FR 8,9 124,0 For more information 07

10 (N)HXH 0,6/1 kv FE180/E30 Power, control and signaling cables, fire resistant, flame retardant, halogen free Conductor 2. Flame protection 3. Insulation 4. Outer sheath APPLICATION: Suitable for power transmission and transmission of electrical signals and commands when you need maximum security against fire, such as emergency lighting and alarm systems, automatic fire detection, fire extinguishing devices, automatic door opening, ventilation systems and air conditioning, emergency telephone systems. INSTALLATION: For fixed installation inside and outside even in wet environments. Can be installed on walls or metal structures, on platforms, pipes, conduits and similar systems. For laying underground direct or indirect. FEATURES DESCRIPTION RULES Conductors: bare copper cl. 5 CEI EN (Tab 9) Flame protection: glass-mica tape thickness > 0,10 mm Insualtion: LSZH compound CEI CEI EN Cores colour code: CEI UNEL HD 308 Outer sheath: LSZH compound M1 type CEI CEI EN Sheath colour code: orange Ral 2004 Fire retardant: CEI EN cat. C Flame retardant: CEI EN Halogen free: (<0,5 mg/g - 0,5%) CEI EN /2 - IEC /2 Reduced toxic gases emission: (toxicity index <2%) CEI 20-37/4-0 Reduced smoke emission: (transmittance >60%) CEI EN Fire resistant: during 90 min. at 830 C C CEI EN per Ø 20 mm Fire resistant: during 120 min. at 830 C C CEI EN per Ø > 20 mm Fire resistant: during 180 min. at 750 C (FE180) IEC VDE Fire resistant: (E30) DIN VDE Electric resistance: according to CEI EN (Tab 9) Current capability: CEI UNEL 35024/1 - CEI UNEL Rated voltage Uo/U: 0,6/1 kv Max voltage: 1,2 kv Testing voltage: 4 kv Max working temperature: 90 C Short circuit temperature: 250 C Min. installation temperature: 0 C Bending radius: Ø x 14 Outer printing: FTC / BERICA CAVI S.P.A. (VI) (N)HXH FE180 / E30 IEC DIN VDE CE Year/Lot Nr cores x/g Section Prog. metric For more information 08

11 (N)HXH 0,6/1 kv FE180/E30 Power, control and signaling cables, fire resistant, flame retardant, halogen free n x mm 2 mm kg/km 1x1,5 7,0 68,0 2x1,5 12,2 191,0 3G1,5 12,8 217,0 4G1,5 13,9 243,0 5G1,5 15,1 298,0 1x2,5 7,5 78,0 2x2,5 13,0 224,0 3G2,5 13,9 264,0 4G2,5 14,9 310,0 5G2,5 16,3 370,0 1x4 8,0 96,0 2x4 14,0 274,0 3G4 15,0 327,0 4G4 16,1 380,0 5G4 17,6 477,0 n x mm 2 mm kg/km 7G1,5 14,2 315,0 10G1,5 17,9 420,0 12G1,5 18,9 492,0 16G1,5 21,1 596,0 19G1,5 22,3 693,0 24G1,5 25,6 880,0 36G1,5 30,5 1230,0 48G1,5 35,1 1620,0 7G2,5 15,8 412,0 10G2,5 19,9 560,0 12G2,5 21,1 650,0 16G2,5 23,6 820,0 19G2,5 25,0 930,0 24G2,5 28,8 1180,0 36G2,5 34,2 1810,0 48G2,5 39,5 2450,0 1x6 8,6 121,0 2x6 15,2 342,0 3G6 16,1 412,0 4G6 17,6 489,0 5G6 19,3 612,0 1x10 9,9 182,0 2x10 17,8 496,0 3G10 18,9 614,0 4G10 20,7 756,0 5G10 22,8 935,0 1x16 11,0 246,0 2x16 20,0 673,0 3G16 21,2 819,0 4G16 23,4 1021,0 5G16 25,7 1267,0 1x25 12,8 353,0 2x25 23,6 900,0 3G25 25,1 1206,0 4G25 27,7 1481,0 5G25 31,0 1868,0 For more information 1x35 13,5 457,0 1x50 15,5 650,0 1x70 17,5 806,0 1x95 20,1 1062,0 1x120 22,6 1342,0 1x150 24,9 1690,0 1x185 27,7 1930,0 1x240 29,1 2500,0 09

12 (N)HXH 0,6/1 kv FE180/E90 Power, control and signaling cables, fire resistant, flame retardant, halogen free Conductor 2. Flame protection 3. Insulation 4. Glass-mica tape 5. Outer sheath APPLICATION: Suitable for power transmission and transmission of electrical signals and commands when you need maximum security against fire, such as emergency lighting and alarm systems, automatic fire detection, fire extinguishing devices, automatic door opening, ventilation systems and air conditioning, emergency telephone systems. INSTALLATION: For fixed installation inside and outside even in wet environments. Can be installed on walls or metal structures, on platforms, pipes, conduits and similar systems. For laying underground direct or indirect. FEATURES DESCRIPTION RULES Conductors: bare copper cl. 5 CEI EN (Tab 9) Flame protection: glass-mica tape thickness > 0,10 mm Insulation: LSZH compound CEI CEI EN Cores colour code: CEI UNEL HD 308 Outer sheath: LSZH compound M1 type CEI CEI EN Sheath colour code: orange Ral 2004 Fire retardant: CEI EN cat. C Flame retardant: CEI EN Halogen free: (<0,5 mg/g - 0,5%) CEI EN /2 - IEC /2 Reduced toxic gases emission: (toxicity index <2%) CEI 20-37/4-0 Reduced smoke emission: (transmittance >60%) CEI EN Fire resistant: During 90 min. at 830 C C CEI EN per Ø 20 mm Fire resistant: Duraing 120 min. at 830 C C CEI EN per Ø > 20 mm Fire resistant: During 180 min. at 750 C (FE180) IEC VDE Fire resistant: (E90) DIN VDE Electric resistance: according to CEI EN (Tab 9) Current capability: CEI UNEL 35024/1 - CEI UNEL Rated voltage Uo/U: 0,6/1 kv Max voltage: 1,2 kv Testing voltage: 4 kv Max working temperature: 90 C Short circuit temperature: 250 C Min. installation temperature: 0 C Bending radius: Ø x 14 Outer printing: FTC / BERICA CAVI S.P.A. (VI) (N)HXH FE180 / E90 IEC DIN VDE CE Year/Lot Nr cores x/g Sect. Progr. Metric For more information 10

13 (N)HXH 0,6/1 kv FE180/E90 Power, control and signaling cables, fire resistant, flame retardant, halogen free n x mm 2 mm kg/km 1x1,5 7,5 71,0 2x1,5 12,7 196,0 3G1,5 13,3 223,0 4G1,5 14,4 249,0 5G1,5 15,6 305,0 1x2,5 8,2 81,0 2x2,5 13,7 230,0 3G2,5 14,4 270,0 4G2,5 15,6 317,0 5G2,5 17,0 378,0 1x4 8,7 99,0 2x4 14,7 280,0 3G4 15,5 334,0 4G4 16,8 388,0 5G4 18,3 486,0 n x mm 2 mm kg/km 7G1,5 14,9 322,0 10G1,5 18,5 429,0 12G1,5 19,6 502,0 16G1,5 21,8 607,0 19G1,5 23,0 705,0 24G1,5 26,3 893,0 36G1,5 31,1 1246,0 48G1,5 35,8 1639,0 7G2,5 16,5 420,0 10G2,5 20,6 570,0 12G2,5 21,8 661,0 16G2,5 24,3 832,0 19G2,5 25,7 943,0 24G2,5 29,4 1195,0 36G2,5 34,9 1828,0 48G2,5 40,2 2471,0 1x6 9,3 125,0 2x6 15,9 349,0 3G6 16,8 420,0 4G6 18,3 498,0 5G6 19,9 622,0 1x10 10,6 186,0 2x10 18,5 505,0 3G10 19,5 623,0 4G10 21,4 766,0 5G10 23,5 947,0 1x16 11,7 251,0 2x16 20,7 683,0 3G16 21,9 830,0 4G16 24,0 1033,0 5G16 26,4 1280,0 1x25 13,5 359,0 2x25 24,3 912,0 3G25 25,8 1219,0 4G25 28,4 1496,0 5G25 31,7 1884,0 For more information 1x35 14,2 464,0 1x50 16,2 658,0 1x70 18,2 815,0 1x95 20,8 1072,0 1x120 23,3 1354,0 1x150 25,6 1703,0 1x185 28,4 1945,0 1x240 29,8 2515,0 11

14 FTG10OM1 0,6/1 kv CEI Power, control and signaling cables, fire resistant, fire retardant, halogen free Conductor 2. Flame protection 3. Insulation 4. Identification thread 5. Outer sheath APPLICATION: Suitable for power transmission and transmission of electrical signals and commands when you need maximum security against fire, such as emergency lighting and alarm systems, automatic fire detection, fire extinguishing devices, automatic door opening, ventilation systems and air conditioning, emergency telephone systems. INSTALLATION: For fixed installation inside and outside even in wet environments. Can be installed on walls or metal structures, on platforms, pipes, conduits and similar systems. Laying underground direct or indirect. VARIANT: Shield in red copper or tinned copper electrolytic annealed. Armor protective metal wire, tape, braided galvanized steel wire. FEATURES DESCRIPTION RULES Conductors: bare copper cl. 5 CEI EN (Tab 9) Flame protector: glass-mica tape thickness > 0,10 mm Insulation: LSZH compound G10 type CEI CEI EN Cores colour code: CEI UNEL HD 308 Identification thread: C type Outer sheath: LSZH compound M1 type CEI CEI EN Sheath colour code: blue RAL 5015 Fire retardant: CEI EN cat. C Flame retardant: CEI EN Halogen free: (<0,5 mg/g - 0,5%) CEI EN /2 - IEC /2 Reduced toxic gases emission: (toxicity index <2%) CEI 20-37/4-0 Reduced smoke emission: (transmittance >60%) CEI EN Fire resistant: during 90 min. at 830 C C CEI EN per Ø 20 mm Fire resistant: during 120 min. at 830 C C CEI EN per Ø > 20 mm Electric resistance: according to CEI EN (Tab 9) Curent capability: CEI UNEL 35024/1 - CEI UNEL Rated voltage Uo/U: 0,6/1 kv Max voltage: 1,2 kv Testing voltage: 4 kv Max working temperature: 90 C Short circuit temperature: 250 C Min. installation temperature: 0 C Bending radius: Ø x 14 Outer printing for Ø 20 mm: FTC / BERICA CAVI S.P.A. (VI) FTG10OM1 0,6/1 kv CEI III cat. C CEI PH(90) CE IEMMEQU Year/Lot - Nr cores x/g sect. Prog. Metric Outer printing for Ø > 20 mm: FTC / BERICA CAVI S.P.A. (VI) FTG10OM1 0,6/1 kv CEI III cat. C CEI F2 CE IEMMEQU Year/Lot - Nr cores x/g sect. Prog. Metric For more information 12

15 FTG10OM1 0,6/1 kv CEI Power, control and signaling cables, fire resistant, fire retardant, halogen free n x mm 2 mm kg/km 1x1,5 7,0 68 2x1,5 12, G1,5 12, G1,5 13, G1,5 15, x2,5 7,5 78 2x2,5 13, G2,5 13, G2,5 14, G2,5 16, x4 8,0 96 2x4 14, G4 15, G4 16, G4 17,6 477 n x mm 2 mm kg/km 7G1,5 14, G1,5 17, G1,5 18, G1,5 21, G1,5 22, G1,5 25, G1,5 30, G1,5 35, G2,5 15, G2,5 19, G2,5 21, G2,5 23, G2,5 25, G2,5 28, G2,5 34, G2,5 39, x6 8, x6 15, G6 16, G6 17, G6 19, x10 9, x10 17, G10 18, G10 20, G10 22, x16 11, x16 20, G16 21, G16 23, G16 25, x25 12, x25 23, G25 25, G25 27, G25 31, For more information 1x35 13, x50 15, x70 17, x95 20, x120 22, x150 24, x185 27, x240 29,

16 FG4OHM1 0,6/1 kv PH(30) Cables for fire detectors shielded with Al/ Pet tape, fire resistant, fire retardant and halogen free Conductor 2. Insulation 3. Assembling 4. Drain wire 5. Al/Pet tape 6. Wire cut-sheath 7. Outer sheath APPLICATION: Suitable for connection between sensors and the control of fire detection systems are required when special features such as fire resistance, reduced smoke opacity, reduced emission of toxic and corrosive gases and halogen-fre. INSTALLATION: For fixed installation indoors and outdoors. Can be installed on bridges, pipes, conduits and similar systems. Is laying underground indirect. FEATURES DESCRIPTION RULES Conductors: bare copper cl. 5 CEI EN (Tab 9) Insulation: ceramizable silicon rubber CEI CEI EN Cores colour code: red and black Assembling: polyester-mylar tape Drain wire: tinned copper 1x0,60 mm Shield: Al/Pet tape Wire cut-sheath: Outer sheath: LSZH compound M1 type CEI CEI EN Sheath colour code: red RAL 3000 Fire retardant: CEI EN cat. C Flame retardant: CEI EN Halogen free: (<0,5 mg/g - 0,5%) CEI EN /2 - IEC /2 Reduced emission of toxic gases: (toxicity index < 2%) CEI 20-37/4-0 Reduced smoke emission: (trasmittance > 60%) CEI EN Fire resistant: during 30 min. at 830 C C CEI EN Electric resistance: according to CEI EN (Tab 9) Rated voltage Uo/U: 0,6/1 kv Max voltage: 1,2 kv Testing voltage: 4 kv Max working temperature: 90 C Short circuit temperature: 250 C Min. installation temperature: 0 C Bending radius: Ø x 14 Outer printing: FTC / BERICA CAVI S.P.A. (VI) FG4OHM1 0,6/1 kv CEI III cat. C CEI EN PH(30) CE Nr of cond. by cross section - Year/Lot - Prog. Metric mm kg/km 2x0,50 6,1 39,0 2x0,75 6,3 49,0 2x1 7,1 61,0 2x1,5 8,0 83,0 2x2,5 9,1 107,0 For more information 14

17 FTG10OHM1 0,6/1 kv Cables for fire detectors shielded with Al/Pet tape, fire resistant, fire retardant and halogen free 1. Conductor 2. Flame protections 3. Insulation 4. Assembling 5. Drain wire 6. Al/Pet tape 7. Outer sheath APPLICATIONS: Suitable for connection between sensors and the control of fire detection systems are required when special features such as fire resistance, reduced smoke opacity, reduced emission of toxic and corrosive gases and halogen-free. INSTALLATION: For fixed installation indoors and outdoors. Can be installed on bridges, pipes, conduits and similar systems. Is laying underground indirect. FEATURES DESCRIPTION RULES Conductors: bare copper cl.5 CEI EN (Tab. 9) Flame protection: glass-fibre tape thickness > 0,10 mm Insulation: LSZH compound G10 type CEI CEI EN Cores colour code: CEI UNEL HD 308 Assembling: polyester-mylar tape Drain wire: tinned copper 7x0,30 mm Shield: Al/Pet tape Outer sheath: LSZH compound M1 type CEI CEI EN Sheath colour code: red RAL 3000 Fire retardant: CEI EN cat. C Flame retardant: CEI EN Halogen free: (< 0,5 mg/g - 0,5%) CEI EN /2 - IEC /2 Reduced emission of toxic gases: (toxicity index < 2%) CEI 20-37/4-0 Reduced smoke emission: (trasmittance > 60%) CEI EN Fire resistant: 90 min. at 830 C C) CEI EN Electric resistance: according to CEI EN (Tab 9) Rated voltage Uo/U: 0,6/1 kv Max voltage: 1,2 kv Testing voltage: 4 kv Max working temperature: 90 C Short circuit temperature: 250 C Min. installation temperature: 0 C Bending radius: Ø x 14 Outer printing: FTC / BERICA CAVI S.P.A. (VI) FIRE RESISTANT ALARM CEI III cat. C CEI EN PH 90 CE 0,6/1 kv Nr of cond. by cross section - Year/Lot - Prog. Metric n x mm 2 mm kg/km n x mm 2 mm kg/km For more information 2x1 8,9 82 3x/G1 9,4 90,2 4x/G1 10, x/G1 11, x/G1 12, x1,5 9, x/G1,5 10, x/G1,5 11,5 145,3 5x/G1,5 12,8 184,1 7x/G1,5 13,9 227,6 2x2,5 10, x/G2,5 11, x/G2,5 12, x/G2,5 14, x/G2,5 15,

18 FTP-UTP 4x2x22 AWG FR Cables for data transmission, fire resistant Conductor 2. Insulation 3. Flame barrier 4. Drain wire 5. Shield 6. Outer sheath APPLICATION: Used to transmit data at high frequency when there is a need to ensure signal transmission even in the presence of a fire. INSTALLATION: For fixed installation inside, without protection or in pipes, embedded or closed systems FEATURES DESCRIPTION RULES Conductors: bare copper 0,63 mm (22AWG) Insulation 1: polyethilene Insulation 2: ceramizable silicon rubber Cores colour code: white/blue - white/orange - white/green - white/brown Fame barrier: glass tape Drain wire: tinned copper 7x0,30 mm Shield: Al/Pet tape Outer sheath: LSZH compound M1 type Sheath colour code: red RAL 3000 Flame retardant: CEI EN Fire resistant: during 30 min. at 830 C (0 +40 C) CEI EN Elctric resistance: < 190 Ω/km (loop) CEI EN /3-1 Characteristic impedance: 100 ± 5Ω a 100 MHz Testing voltage: 700 Vac x 1 min. Max working temperature: 70 C Min. installation temperature: 0 C Bending radius: Ø x 8 Outer printing (FTP): FTC / BERICA CAVI S.P.A. (VI) FTP 4x2x22AWG FR 100 OHM Year/Lot - Prog. metric Outer printing (UTP): FTC / BERICA CAVI S.P.A. (VI) UTP 4x2x22AWG FR 100 OHM Year/Lot - Prog. metric mm kg/km FTP 4x2x22AWG 10,2 108 UTP 4x2x22 AWG 10,0 105 For more information 16

19 RTE4XOHM1FM1 300/500 V BS TYPE 2 (CU/MGT/XLPE/OSCR/LSZH/SWA/LSZH-MGT/2X(St)HRH) Instrumentation cables halogen free, fire resistant, shielded and steel wires armoured 1. Conductor 2. Glass-mica tape 3. Insulation 4. Assembling 5. Drain wire 6. Shield 7. Inner sheath 8. Armouring 9. Outer sheath APPLICATION: Circuits used in instrumentation in refineries, petrochemical and oil deposits when it is necessary to ensure signal transmission during a great fire. INSTALLATION: For fixed installation indoors and outdoors. Can be installed on bridges, pipes, conduits and similar systems. It is laying underground. VARIATIONS: steel braid armor - armor steel belts. FEATURES DESCRIPTION RULES Conductor: bare copper class 2-5 BS 6360 Flame protection: glass - mica tape thickness > 0,10 mm Insulation: XLPE crosslinked polyethylene type GP8 BS 7655 Cores colour code: BS Assembling: polyester-mylar tape Drain wire: fine wires stranded of tinned copper 7x0,30 mm Shield: Al/Pet 25/23 µm tape Inner sheath: LSZH compound M1 type CEI EN Armouring: steel wires helically wound Outer sheath: LSZH compound M1 type CEI EN Sheath colour code: blue RAL black RAL 9005 Flame retardant: CEI EN Fire resistant: 3 h at 750 C IEC Electric resistance: according to BS Rated voltage Uo/U: 300/500 V Testing voltage: 1000 V Max working temeprature: 80 C Min installation temeprature: 0 C Bending radius: Ø x 14 Outer sheath: FTC / BERICA CAVI S.P.A. (VI) RTE4XOHM1FM1 300/500 V CEI EN Nr Cores x Sect. Year/Lot Prog. Metric TYPE (*) MEDIUM Ø OUTER MEDIUM WEIGHT Nr. x mm 2 mm kg/km For more information 1P x 1,5 13, P(Q) x 1,5 14, P x 1,5 20, P x 1,5 31, T x 1,5 13, P x 2,5 14, P(Q) x 2,5 16, P x 2,5 27, (*) P=Pair T=Third Q=Fourth 17

20 ALARM CABLE LS0H RED COPPER SCREENED Cables for security systems Conductor 2. Insulation 3. Assembling 4. Drain wire 5. Al/Pet tape 6. Outer sheath APPLICATION: Used for connections in intrusion detection systems. INSTALLATION: For fixed installation in ordinary or damp environment in and outside temporarily. They can be installed on platforms, pipes, conduits, and similar systems. It is not for laying underground. FEATURES DESCRIPTION RULES Conductors: bare copper cl. 5 Insulation: polyethylene Cores colour code: alarm colour (Tab 1) - red and black (supply) Assembling: polyester-mylar tape Drain wire: bare copper 7x0,18 mm Shield: Al/Pet tape Outer sheath: LSZH compound M1 type CEI CEI EN Sheath colour code: withe RAL 9010 and red RAL 3000 Halogen free: (<0,5 mg/g - 0,5%) CEI EN /2 - IEC /2 Rated voltage Uo/U: 300/300 V Max voltage: 330 V Testing voltage: 2000 V Max working temperature: 70 C Short circuit temperature: 160 C Min. installation temperature: 0 C Bending radius: Ø x 8 Outer printing: on request n x mm 2 mm kg/km 2x0,22 3, x0,22 3, x0,22 4, x0,22 4, x0,22 5, x0,22 5, x0,22 5, x0,22 6, x0,22 6, x0,22 7, x0,22 7, x0,50+2x0,22 4, x0,50+4x0,22 5, x0,50+6x0,22 4,30 37 n x mm 2 mm kg/km 2x0,50+8x0,22 5, x0,50+10x0,22 6, x0,50+12x0,22 6, x0,75+2x0,22 4, x0,75+4x0,22 5, x0,75+6x0,22 5, x0,75+8x0,22 5, x0,75+10x0,22 6, x0,75+12x0,22 6, x0,75+ 14x0,22 7, x0,75+16x0,22 7, x0,75+18x0,22 7, x0,75+20x0,22 7, x0,75+30x0,22 9, For more information 18

21 J-H(ST)H BRANDMELDEKABEL LS0H Cables for security systems 1. Conductor 2. Insulation 3. Assembling 4. Drain wire 5. Al/Pet tape 6. Outer sheath APPLICATIONS: Used for connections in intrusion detection systems and fire detection systems. INSTALLATION: For fixed installation indoors and outdoors. Can be installed on bridges, pipes, conduits and similar systems. Is laying underground indirect. FEATURES DESCRIPTION RULES Conductors: bare copper cl.1 Insulation: polyethylene Cores colour code: 2x(red-blue), 4x(white-red-yellow-black), 3x2x(red/blue - white/yellow - white/green), 4x2x(red/blue - white/yellow - white/green - white/brown) Assembling: polyester-mylar tape Drain wire: bare copper 1x0,50 mm Shield: Al/Pet tape Outer sheath: LS0H compound M1 type CEI CEI EN Sheath colour code: red RAL 3000 Halogen free: (< 0,5 mg/g - 0,5%) CEI EN /2 - IEC /2 Rated voltage Uo/U: 300/300 V Max voltage: 330 V Testing voltage: 2000 V Max working temperature: 70 C Short circuit temperature: 160 C Min. installation temperature: 0 C Bending radius: Ø x 8 Outer printing: FTC / BERICA CAVI S.P.A. (VI) J-H(ST)H n x Ø mm BRANDMELDEKABEL Year/Lot mm kg/km For more information 1x2x6/10 3,8 22 4x6/10 4,4 31 3x2x6/10 5,3 41 4x2x6/10 6,0 51 1x2x8/10 4,8 31 4x8/10 4,9 42 3x2x8/10 6,7 61 4x2x8/10 7,

22

23 ALARM CABLE TINNED UNSCREENED - UK TYPE ALARM CABLE TINNED SCREENED - UK TYPE ALARM CABLE RED COPPER SCREENED - EUROPEAN TYPE ALARM CABLE RED COPPER UNSCREENED - EUROPEAN TYPE ALARM CABLE 6/10 SCREENED - FRENCH TYPE ALLARM CABLE LS0H RED COPPER SCREENED ALARM CABLE 5/10 24 AWG RED FIRE UNSCREENED ALARM CABLE 5/10 24 AWG RED FIRE SCREENED MULTICORE RED FLEX COPPER UNSCREENED MULTICORE RED FLEX COPPER SCREENED MULTICORE RED SOLID COPPER UNSCREENED MULTICORE RED SOLID COPPER SCREENED LSOH 5/10 SCREENED LSOH MULTICORE RED FLEX SCREENED ALARM 450/750 V LSOH CCTV COMBI VIDEO COMBI MINI RG 59 VIDEO COMBI MINI COAX VIDEO SPEAKER ELVOX TYPE RG x1 + 9x0,50 VIDEO COMBI RG 59 For tecnichal specification see

24 RG 11 RG 11 E RG 213 RG 58 RG 59 MINI RG 59 MINICOAX RG 174 RG 6 SAT 5 19 VATC A 19 VATC 17 VATC A 17 VATC UTP CAT 5E UTP CAT 6 LSOH FTP CAT 5E FTP CAT 6 LSOH Y(ST)Y BUS EIB FTP-UTP FIRE RESISTANT For tecnichal specification see

25 JX-Y(ST)Y BRANDMELDEKABEL J-YY BRANDMELDEKABEL J-H(ST)H LSOH BRANDMELDEKABEL ACOMETIDA INTERIOR 5/10 UK CW /10 NBN SVV-F2 8/10 NBN VVT-F2 6/10 NBN TVVF-F2 8/10 YYSCH YR 8/10 SYT NF-USE (SYS) LSOH STRAND WIRE PERMUTATION STRAND WIRE 450/750 V SOLID WIRE PERMUTATION TELEPHONE CABLE SUBSCRIBER C.T TELEPHONE CABLE DROP C.T TELEPHONE TEGHR C.T TELEPHONE TRR For tecnichal specification see

26 OM1 MULTIMODAL STEEL ARMOURED OM1 MULTIMODAL DIELECTRIC ARMOURED OM2 MULTIMODAL STEEL ARMOURED OM2 MULTIMODAL DIELECTRIC ARMOURED OM3 MULTIMODAL STEEL ARMOURED OM3 MULTIMODAL DIELECTRIC ARMOURED OS1 SINGLEMODE STEEL ARMOURED OS1 SINGLEMODE DIELETRIC ARMOURED ALLARM 0,6/1 kv FR2OHH2R 0,6/1 kv FROR 0,6/1 kv RG 59 UTP-FTP CAT. 5E UTP-FTP CAT. 6 VIDEO SPEAKER ELVOX TYPE Mini RG59+3x1+9x0.50 VIDEO COMBI MINI RG 59 H05VVH6-F 300/500 V IMQ H07VVH6-F 300/500 V IMQ LOUD SPEAKER FRW 300/300 V For tecnichal specification see

27 EMV 2XSLCY-J 0,6/1 kv 3x EMV 2XSLCY-J 0,6/1 kv 4x FG7OH1R 0,6/1 kv FG7OH2M1 0,6/1 kv IMQ FG7OH2R 0,6/1 kv FG7OH2R+T 0,6/1 kv (INVERTER) FG7OH2R+T+ST 0,6/1 kv (INVERTER) FG7OHH2R 0,6/1 kv (INVERTER) FR2OHH2R 450/750 V FR2OHH2R 450/750 V 0,22 1 mm 2 1,5 10 mm 2 LiYCY 450/750 V 2YSL(St)CYv - JB UTP-FTP CAT. 5E ARMOURED UTP-FTP CAT. 6 ARMOURED FG7OAM1 0,6/1 kv FG7OAR 0,6/1 kv FG7OFR 0,6/1 kv FG7ONR 0,6/1 kv FRORAR 450/750 V For tecnichal specification see

28 REXHOEFR 300/500 V BS REXHOHEFR 300/500 V BS REXHOHR 300/500 V BS REXHOR 300/500 V BS FR2XHOHRAR MONTEDISON FR2XHOHRFR ENI SNAM RE4XHOHRFR 300/500 V RE - 2Y(St)Y - FL RE - 2Y(St)Y SWA - FL NFM INSTRUMENTATION CABLE SIF - FG4 300/500 V SIHF - FG4G4 300/500 V SIF - GL - FG4T2 300/500 V SIHF - GL - FG4G4T2 300/500 V SIHF - P - FG4G4A 300/500 V SIHF - GL - P - FG4G4T1A 300/500 V FG4G4H2G4 300/500 V FG4OR 300/500 V For tecnichal specification see

29

30 SOLAR CABLE CONNECTING CABLE FOR PHOTOVOLTAICS PANELS Outer sheath Insulation Conductor TECHNICAL FEATURES Conductors: tinned copper CEI EN Cl.5 rule (Tab. 9) Insulation: crosslinked polyolefine 2Pfg 1169/ Outer sheath: crosslinked polyolefine 2Pfg 1169/ Sheath color code: black RAL 9005, red RAL 3013 or blue RAL 5015 Flame retardant: CEI EN rule Halogen free: (<0,5 mg/g - 0,5 %) CEI EN /2 - IEC /2 rule Low emission toxic gas: (toxicity index < 2 %) CEI 20-37/4-0 rule Low smoke: (transmittance > 60 %) CEI EN rule UV resistant: HD 605 rule Ozone resistant: CEI EN rule Long-term behavior: (20000 h at 120 C) CEI EN rule DC resistance: according to CEI EN (Tab 9) rule Current capacity: 2Pfg 1169/ Rated voltage: 0,6/1 kvac 0,9/1,5 kvdc Max voltage: 1,2 kvac 1,8 kvdc Test voltage: 6,5 kvac 15 kvdc Max operating temperature: 90 C Short circuit temperature: 250 C Min. installation temperature: -25 C Min. bending radius: Ø x 6 Outer printing: BERICA CAVI S.P.A. (VI) SOLAR CABLE 1x Section - Year/Lot - PV1-F Vcc IEC CE TÜV N. Certificate n. R (black and red) n. R (blue) FG21M21 TYPE * Ø MEDIUM OUTER MEDIUM WEIGHT n x mm 2 mm kg x km 1x2,5 5,1 47,0 1x4 5,7 63,0 1x6 6,5 86,0 1x10 7,9 136,0 1x16 9,0 195,0 1x25 10,9 291,0 1x35 11,9 383,0 1x50 14,1 552,0 1x70 15,9 712,0 1x95 18,0 925,0 1x120 20,3 1187,0 1x150 22,8 1476,0 1x180 26,0 1785,0 1x240 27,0 2390,0 (*) BLACK, RED AND BLUE

31 SOLAR CABLE 0,6/1 kv CONCENTRATOR FOR APPLICATIONS IN SOLAR CONCENTRATORS SYSTEMS Outer sheath Al/Pet Insulation Conductor TECHNICAL FEATURES Conductors: tinned copper CEI EN rule Insulation: crosslinked polyolefin red and black Reflective shield: aluminum tape with the metal to the ouside Outer sheath: special PVC Sheath colour code: transparent Flame retardant: CEI EN rule UV resistant: HD 605 rule Ozone resistant: CEI EN rule Dump heat resistant: CEI EN rule DC resistance: CEI EN rule Rated voltage Uo/U: 0,6/1 kvac 0,9/1,5 kvdc Max voltage: 1,2 kv 1,8 kvdc Test voltage: 6,5 kvac 15 kvdc Max operating temperature: 90 C Short circuit temperature: 250 C Min. installation temperature: -25 C Min. bending radius: Ø x 6 Outer printing: BERICA CAVI S.P.A. (VI) SOLAR CABLE CONCENTRATOR 1x Sect. Year/Lot 1500 Vcc IEC CE (*) BLACK AND RED TYPE * Ø MEDIUM OUTER MEDIUM WEIGHT n x mm 2 mm kg x km 1x2,5 6,5 57,0 1x4 7,0 75,0 1x6 7,8 100,0

32 SOLAR CABLE 2X SIDE BY SIDE SOLAR CABLE Outer sheath Insulation Conductor TECHNICAL FEATURES Conductors: tinned copper CEI EN (Tab. 9) rule Insulation: crosslinked polyolefine Cores colours: red and black Outer sheath: crosslinked polyolefine Sheath colour code: black RAL 9005 Flame ratardant: CEI EN rule Halogen free: (< 0,5 mg/g - 0,5%) CEI EN /2 - IEC /2 rule Low emission toxic gas: (toxicity index <2 %) CEI 20-37/4-0 rule Low smoke: (transmittance > 60 %) CEI EN rule UV resistant: HD 605 rule Ozone resistant: CEI EN rule Long-term behavior: (20000 h at 120 C) CEI EN rule DC resistance: according to CEI EN (Tab. 9) rule Rated voltage: 0,6/1 kvac 0,9/1,5 kvdc Max voltage : 1,2 kvac 1,8 kvdc Test voltage: 6,5 kvac 15 kvdc Max operating temperature: 90 C Short circuit temperature: 250 C Min. installation temperature: -25 C Min. bending radius: Ø x 6 Outer printing: BERICA CAVI S.P.A. (VI) SOLAR CABLE 2x - Sect. Year/Lot PV1-F 1500 Vcc IEC CE Prog. metric TYPE Ø MEDIUM OUTER MEDIUM WEIGHT n x mm 2 mm kg x km 2x2,5 5,20 x 10, x4 6,00 x 12, x6 6,80 x 13, x10 8,20 x 16, x16 9,30 x 18,80 420

33 SOLAR CABLE ARMOUR CONNECTING CABLE FOR PHOTOVOLTAICS PANELS Outer sheath Armouring PET Insulation Conductor TECHNICAL FEATURES Conductors: tinned copper CEI EN (Tab. 9) rule Insulation: crosslinked polyolefine Assembling: polyester-mylar tape Armouring: steel wires braid Outer sheath: crosslinked polyolefine Sheath colour code: black RAL 9005 Flame retardant: CEI EN rule Halogen free: (< 0,5 mg/g - 0,5 %) CEI EN /2 - IEC /2 rule Low emission toxic gas: (toxicity index < 2 %) CEI 20-37/4-0 rule Low smoke: (transmittance > 60 %) CEI EN rule UV resistant: HD 605 rule Ozone resistant: CEI EN rule Long-term behavior: (20000 h at 120 C) CEI EN rule DC resistance: according to CEI EN (Tab.9) rule Rated voltage: 0,6/1 kvac 0,9/1,5 kvdc Max voltage : 1,2 kvac 1,8 kvdc Test Voltage: 6,5 kvac 15 kvdc Max operating temperature: 90 C Short circuit temperature: 250 C Min. installation temperature: -25 C Min. bending radius: Ø x 14 Outer printing: BERICA CAVI S.P.A. (VI) SOLAR CABLE ARMOUR Section - Year/Lot PV1-F Vcc IEC CE progr. metric TYPE Ø MEDIUM OUTER MEDIUM WEIGHT n x mm 2 mm kg x km 1x1 BLACK 6,6 62,0 1x1,5 BLACK 7,1 74,0 1x2,5 BLACK 7,6 91,0 1x4 BLACK 8,4 116,0 1x6 BLACK 9,1 144,0 1x10 BLACK 10,5 207,0 1x16 BLACK 11,9 283,0 1x25 BLACK 13,2 381,0 1x35 BLACK 14,6 490,0 1x50 BLACK 16,6 672,0 1x70 BLACK 18,7 854,0 1x95 BLACK 21,3 1112,0 1x120 BLACK 23,9 1395,0 1x150 BLACK 25,7 1688,0 1x185 BLACK 28,4 2002,0 1x240 BLACK 29,6 2626,0

34 Factory: Fabbrica Trentina Conduttori s.r.l Z.I. Pineta Via Pineta 21/B Rovereto ( TN ) - Italy Tel Fax info@fctsecuritycables.com aprile 2010

35 Factory: Fabbrica Trentina Conduttori s.r.l Z.I. Pineta Via Pineta 21/B Rovereto ( TN ) - Italy Tel Fax info@fctsecuritycables.com

Caledonian Flame Retardant Coaxial Cables

Caledonian Flame Retardant Coaxial Cables Caledonian Flame Retardant Coaxial Cables www.caledonian-cables.co.uk www.addison-cables.com Flame Retardant RG59 Coaxial cables LSZH Outer Sheath Tinned Copper Braid Aluminium+polyester/Aluminium Tape

More information

Flame Retardant Overall Screened Instrumentation Cables (multicore)

Flame Retardant Overall Screened Instrumentation Cables (multicore) Flame Retardant Overall Screened Instrumentation Cables (multicore) RE-2X(St)H RE-2X(St)HSWAH LSZH Outer Sheath Tinned Copper Drain Wire LSZH Inner Sheath XLPE Insulation Plain Annealed Copper Aluminium/polyester

More information

FIRE RESISTANT CABLES

FIRE RESISTANT CABLES Conducting Value The Last Cable Standing FIRE RESISTANT CABLES 100/7b ISO 9001:2008 Certificate No. CS1-249 MANAGEMENT SYSTEMS Assessed to ISO 9001:2008 Cert/LPCB ref. 217 GOST ISO 9001-2011 (ISO 9001:2008)

More information

Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design.

Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design. ADDISON Flame Retardant RG59 B/U Coaxial cables Plain copper wire braid PE Solid Bare Copper PVC Outer Sheath APPLICATION The cables are designed for CCTV, security, smoke detection and evacuation monitoring

More information

BS EN :2004. Test On Electric And Optical Fibre Cables Under Fire Conditions. WF Report Number. Date: 14 th November 2008.

BS EN :2004. Test On Electric And Optical Fibre Cables Under Fire Conditions. WF Report Number. Date: 14 th November 2008. BS EN 60332-1-2:2004 Test On Electric And Optical Fibre Cables Under Fire Conditions WF Report Number 177603 Date: 14 th November 2008 Test Sponsor: FTC Fabbrica Trentina Conduttori Srl 0249 Page 2 of

More information

600/1000V SR Insulated Flexibles Control Cables (2-4 Cores & Multicores)

600/1000V SR Insulated Flexibles Control Cables (2-4 Cores & Multicores) 600/1000V SR Insulated Flexibles Control Cables (2-4 Cores & Multicores) FFX400 1SZ1-R(PH60)(CU/SR/LSZH 600/1000V Class 2) FFX400 1SZ1-F(PH60)(CU/SR/LSZH 600/1000V Class 5) Silicone Rubber Insulation Plain

More information

IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission

IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission ADDISON Flame Retardant CAT5e Data Cables FTX-CAT5e U/UTP4P24 FTX-CAT5e f/utp4p24 FTX-CAT5e sf/utp4p24 LSZH Outer Aluminium/Polyester Tape Solid Copper Conductor PE Insulation Tinned Copper Drain Wire

More information

PRODUCT CATALOGUE Norröna

PRODUCT CATALOGUE  Norröna PRODUCT CATALOGUE Norröna WWW.SCANKAB.COM Table of contents MARINE AND OFFSHORE CABLES 1 TOXFREE XZ1-K (AS) - 0.6/1 kv 1 TOXFREE MARINE XO2TCuZ1-K (AS) - 150/250 V 5 4x2xAWG 24/1 CAT6 S/FTP LSZH-SHF1 -

More information

Caledonian Fire resistant Coaxial Cables

Caledonian Fire resistant Coaxial Cables Caledonian Fire resistant Coaxial Cables www.caledonian-cables.net www.addison-cables.com Fire resistant rg59 b/u Coaxial Cables RG59 B/U FR LSZH Sheath Fire Resistant Tape Copper Clad Steel/Bare Copper

More information

600/1000V XLPE Insulated, LSZH Sheathed, Double steel tape Armoured Power Cables (3 Cores)

600/1000V XLPE Insulated, LSZH Sheathed, Double steel tape Armoured Power Cables (3 Cores) Caledonian Flame Retardant Power & Control Cables www.caledonian-s.co.uk www.addison-s.com 600/1000V XLPE Insulated, LSZH Sheathed, Double steel tape Armoured Power Cables (3 Cores) FTX400 1RZ1MZ1-R (CU/XLPE/LSZH/DSTA/LSZH

More information

Caledonian fire Resistant signal & Data cables

Caledonian fire Resistant signal & Data cables fire Resistant signal & Data cables www.addison-tech.com fire Resistant Rs485 Databus cables Copper Wire Braid(optional) Individual AL/Polyester Tape(optional) Mica Glass Tape+PE/PE+Silicone Rubber Insulation

More information

High Performance LSZH Fire Resistant Cable

High Performance LSZH Fire Resistant Cable High Performance LSZH Fire Resistant Cable www.cavicel.com 104/2 FIRECEL SR 114H is the long and well established CAVICEL fire resistant cable in the market, since many years. These cables are third party

More information

Double insulated, electron-beam cross-linked, halogen free photovoltaic wire sunlight resistant. Single conductor, flame retardant insulation.

Double insulated, electron-beam cross-linked, halogen free photovoltaic wire sunlight resistant. Single conductor, flame retardant insulation. Technical Data Sheet BETAflam Solar 125 flex UL 4703 Description Double insulated, electron-beam cross-linked, halogen free photovoltaic wire sunlight resistant. Single conductor, flame retardant insulation.

More information

IEC UNE DESIGN. 1. Conductor. 2. Insulation. Cross-linked polyethylene (XLPE) 3. Outer sheath. Flexible PVC, black colour.

IEC UNE DESIGN. 1. Conductor. 2. Insulation. Cross-linked polyethylene (XLPE) 3. Outer sheath. Flexible PVC, black colour. 67 POWERFLEX RV-K POWERFLEX RV-K Industrial flexible cable for power transmission. 1 IEC 60502-1 - UNE 21123-2 DESIGN 1. Conductor 2 Electrolytic copper, class 5 (flexible), based on EN 60228 and IEC 60228.

More information

BS EN : Measurements Of Smoke Density Of Electric Cables. WF Report Number. Date: 17 th November Test Sponsor:

BS EN : Measurements Of Smoke Density Of Electric Cables. WF Report Number. Date: 17 th November Test Sponsor: BS EN 61034-2: 2005 Measurements Of Smoke Density Of Electric Cables WF Report Number 177599 Date: 17 th November 2008 Test Sponsor: FTC Fabbrica Trentina Conduttori Srl 0249 Page 2 of 13 Bodycote warringtonfire

More information

IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission

IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission Flame Retardant RS485 Databus Cables Copper Wire Braid(optional) Individual AL/Polyester Tape(optional) Foam PE/Foam skin PE. Stranded Tinned Copper AL/Polyester Tape With Tinned Copper Drain Wire LSZH

More information

BS EN :2004. Test On Electric And Optical Fibre Cables Under Fire Conditions. WF Report Number. Date: 14 th November 2008.

BS EN :2004. Test On Electric And Optical Fibre Cables Under Fire Conditions. WF Report Number. Date: 14 th November 2008. BS EN 60332-1-2:2004 Test On Electric And Optical Fibre Cables Under Fire Conditions WF Report Number 177604 Date: 14 th November 2008 Test Sponsor: FTC Fabbrica Trentina Conduttori Srl 0249 Page 2 of

More information

Cable technology for highest safety requirements

Cable technology for highest safety requirements Cable technology for highest safety requirements Daetwyler We are a provider of high-grade quality system solutions and services in the areas of structured data cabling, telecom carriers, safety cabling,

More information

Firecel Safety Cables

Firecel Safety Cables 103/7 Firecel Safety Cables Low Smoke - Zero Halogen www.cavicel.com Firecel Safety Cables Low Smoke - Zero Halogen Over the last 30 years CAVICEL has developped a deep experience in studying, designing

More information

Photovoltaic Cables EN H1Z2Z2-K

Photovoltaic Cables EN H1Z2Z2-K Photovoltaic Cables EN 50618 H1Z2Z2-K COMPANY PROFILE Caledonian, established in 1978, offers one of the most complete lines of fiber and copper cabling system solutions with over hundreds of different

More information

BS 6387: 1994 Specification for performance requirements for cables required to maintain circuit integrity under fire conditions.

BS 6387: 1994 Specification for performance requirements for cables required to maintain circuit integrity under fire conditions. BS 6387: 1994 Specification for performance requirements for cables required to maintain circuit integrity under fire conditions WF Report Number: 147709 Test Sponsor: FTC - Fabbrica Trentina Conduttori

More information

The Quality Connection. BETAflam Fire Resistant Safety Cables

The Quality Connection. BETAflam Fire Resistant Safety Cables The Quality Connection BETAflam Fire Resistant Safety Cables BETAflam Contact Your personal customer number To offer you a more efficient service, we kindly ask you to mention your personal customer number

More information

fire resistant cables

fire resistant cables Building Technology fire resistant cables Special electrical and optical cables www.tecnikabel.com Special electrical and optical cables 2 INTRODUCTION Structured cabling solutions. Tecnikabel can provide

More information

Method of test defined in IEC for determining the circuit integrity performance of a cable under fire conditions.

Method of test defined in IEC for determining the circuit integrity performance of a cable under fire conditions. Method of test defined in IEC 60331-21 for determining the circuit integrity performance of a cable under fire conditions. WF Report Number: 148371 Test Sponsor: FTC - Fabbrica Trentina Conduttori Srl

More information

SPECIAL ELECTRICAL AND OPTICAL CABLES

SPECIAL ELECTRICAL AND OPTICAL CABLES SPECIAL ELECTRICAL AND OPTICAL CABLES INTRODUCTION The new high-speed trains and the sensible increase of the traffic, with congested lines, is the result of the latest development of the rail sector.

More information

Fire alarm cables. for highest safety requirements TRADITION INNOVATION PASSION

Fire alarm cables. for highest safety requirements TRADITION INNOVATION PASSION Fire alarm cables for highest safety requirements TRADITION INNOVATION PASSION Datwyler Datwyler Cabling Solutions is an internationally operating company with its headquarters in Switzerland and affiliates

More information

600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (Multicore)

600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (Multicore) 600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (Multicore) FGD400 1RV-R (CU/XLPE/PVC 600/1000V Class ) FGD400 1RVMV-R (CU/XLPE/PVC/SWA/PVC 600/1000V Class ) PVC Outer Sheath Plain Annealed

More information

Introduction.

Introduction. Introduction The safety of occupants and users of public, commercial and industrial premises is of paramount importance. One important safety feature is the appropriate use of fire performance cables for

More information

AFIREFENIX SZ1-K 0,6/1 kv PH120 (AS+)

AFIREFENIX SZ1-K 0,6/1 kv PH120 (AS+) Page 1 / 7 Construction and tests. Standards: UNE 211025 Compliance with the Low Voltage Directive (LVD): 2014/35 / EU Construction Products Regulation (CPR) - Regulation (EU) Nº 305/2011: Reaction to

More information

Catalogue Telecommunication Cables INTRODUCCIÓN

Catalogue Telecommunication Cables INTRODUCCIÓN Catalogue Telecommunication Cables INTRODUCCIÓN Conductores Tecnológicos S.A. www.contecsa.es Index of Cables Page Introduction 3 EAP / EAP-R 4 EAPSP / EAPSP-R 5 ISP / ICP 6 Conductores Tecnológicos S.A.

More information

Core identification code. J-YY...BD Indoor Cable. J-YY...BD Indoor Cable. VDE 0815 Mutual capacitance. J-YY...BD Indoor Cable. Cu conductor 0.

Core identification code. J-YY...BD Indoor Cable. J-YY...BD Indoor Cable. VDE 0815 Mutual capacitance. J-YY...BD Indoor Cable. Cu conductor 0. Indoor cables J-YY...BD Indoor J-Y(ST)Y..LG Indoor Comparable products UNITRONIC J-2Y(ST)Y...ST III BD see page 271 Indoor telephone cables transmit analogue or digital signals In news and communication

More information

Traction Cable Radox 3 GKW

Traction Cable Radox 3 GKW General Properties : Excellent high temperature, low temperature, ozone and weathering resistance, zero halogen, flame retardant, solder iron resistant, easily strippable, flexible. Application : Single

More information

OIL & GAS INDUSTRY OTHER INDUSTRIES

OIL & GAS INDUSTRY OTHER INDUSTRIES For ATEX Areas OIL & GAS INDUSTRY OTHER INDUSTRIES OIL & GAS INDUSTRY POTENTIALLY HAZARDOUS Class I GASES VAPORS LIQUIDS Petrosumsave Zone 0 An area in which an explosive mixture is continuously present,

More information

CABLES FOR ALARM AND SAFETY SYSTEMS

CABLES FOR ALARM AND SAFETY SYSTEMS CABLES FOR ALARM AND SAFETY SYSTEMS 2 IT S ALL ABOUT RELIABILITY. It is always important to choose high quality cables, especially when it comes to alarms and safety systems. Even small and seemingly insignificant

More information

Company Profile. We are dedicated to providing our customers competitive price and excellent service.

Company Profile. We are dedicated to providing our customers competitive price and excellent service. 1 Company Profile Hangzhou Kingtone Electronics Co., Limited is a Chinese wire & cable manufacturer specializing in manufacturing Coaxial Cable, Lan Cable, Alarm/Security Cable, Power Cable, Speaker Cable

More information

Catalogue. Instrumentation & Control Cables

Catalogue. Instrumentation & Control Cables Catalogue Instrumentation & Control Cables Conductores Tecnológicos S.A. www.contecsa.es Index of Cables Page Introduction 3 Instrumentation VOV 4 VHOV 5 VOVMV 6 VHOVMV 7 Control RV 8 RZ1C3Z1 9 Conductores

More information

System Circuit integrity in the event of fire. Safety cables and systems from a pro. Cabling Solutions

System Circuit integrity in the event of fire. Safety cables and systems from a pro. Cabling Solutions System Circuit integrity in the event of fire and systems from a pro Cabling Solutions Safety cable systems Halogen-free safety cables with reference to VDE H05Z-K, H07Z-K / U / R 22 NHXMH, (N)HXM(St)H

More information

PHOTOVOLTAIC CABLES. Photovoltaic Cable 2000V/1500V Photovoltaic Cable 2000V/1000V

PHOTOVOLTAIC CABLES. Photovoltaic Cable 2000V/1500V Photovoltaic Cable 2000V/1000V PHOTOVOLTAIC CABLES PHOTOVOLTAIC CABLES INDEX n AmerSol Dual-Certified (UL / ETL) Photovoltaic Cable 2000V/1500V....................... 2-3 n AmerSol Dual-Certified (UL / ETL) Photovoltaic Cable 2000V/1000V.......................

More information

Telecommunication Cables

Telecommunication Cables Telecommunication Cables Telecommunication Cables Introduction 3 EAP / EAP-R 4 EAPSP / EAPSP-R 5 ISP / ICP 6 Page ELECWIRES 2 www.elecwires.es INTRODUCCIÓN Telecommunication Cables Telephone cables suitable

More information

SAS Security and Alarm Safety Cables

SAS Security and Alarm Safety Cables CABLES Security and Alarm Safety Cables Security and Alarm Safety Cables LOW SMOKE ZERO HALOGEN The right range of cables for modern building installations e-catalogue 203/4 Flexible solutions for commercial,

More information

LV FIRE RESISTANT CABLES

LV FIRE RESISTANT CABLES LV FIRE RESISTANT CABLES CONTENTS 3 GENERAL INTRODUCTION LV FIRE RESISTANT CABLES TECHNICAL INFORMATION 4 9 12 24 26 GENERAL CABLE STRUCTURE ELECTRICAL CHARACTERISTICS CURRENT RATING VOLTAGE DROP SHORT

More information

Firetuf Cables ZERO HALOGEN, LOW SMOKE (0HLS ) CABLE

Firetuf Cables ZERO HALOGEN, LOW SMOKE (0HLS ) CABLE Firetuf Cables ZERO HALOGEN, LOW SMOKE (0HLS ) CABLE Draka, the world s mo When it comes to specifying fire performance cables, zero halogen building wires and power cables, you have to choose products

More information

Firetuf Cables ZERO HALOGEN, LOW SMOKE (0HLS ) CABLE

Firetuf Cables ZERO HALOGEN, LOW SMOKE (0HLS ) CABLE Firetuf Cables ZERO HALOGEN, LOW SMOKE (0HLS ) CABLE Draka, the world s most trusted cable brand When it comes to specifying fire performance cables, zero halogen building wires and power cables, you have

More information

The Quality Connection. BETAflam safety cables for highest demands

The Quality Connection. BETAflam safety cables for highest demands The Quality Connection BETAflam safety cables for highest demands 2 For solutions that will still be standard tomorrow. BETAflam safety cables Thanks to their proven quality, BETAflam safety cables are

More information

Power Control Cable Iec

Power Control Cable Iec POWER CONTROL CABLE IEC 60502 1 PDF - Are you looking for power control cable iec 60502 1 Books? Now, you will be happy that at this time power control cable iec 60502 1 PDF is available at our online

More information

ENHANCED FIRE PERFORMANCE CABLE

ENHANCED FIRE PERFORMANCE CABLE FIRE PERFORMANCE CABLE Manufactured to BS 7629-1 Table 1 Plain Annealed Copper Conductors / Silicone Rubber Insulated / Glass Fibre Tape / Tinned Copper Circuit Protective Conductor / Double Layer of Copper/Polyester

More information

FIRE PERFORMANCE CABLE

FIRE PERFORMANCE CABLE FIRE PERFORMANCE CABLE Manufactured to BS 7629-1 Table 1 Plain Annealed Copper Conductors / Silicone Rubber Insulated / Double Layer of Aluminium/ Polyester Laminated Tapes / Circuit Protective Conductor

More information

BS /1000V XLPE Insulation LSZH Sheath Cables

BS /1000V XLPE Insulation LSZH Sheath Cables BS 8573 600/1000V XLPE Insulation LSZH Sheath Cables Caledonian www.addison-cables.com Company Profile Caledonian & Addison, branded under Caledoniea & Addimax, established in 1978, offers one of the most

More information

GUCN. Central Loose Tube Cables Universal Indoor / Outdoor - Corrugated Steel Tape Armor (CST) A/I-DQ(ZN)(SR)H Full Rodent Protection v13.

GUCN. Central Loose Tube Cables Universal Indoor / Outdoor - Corrugated Steel Tape Armor (CST) A/I-DQ(ZN)(SR)H Full Rodent Protection v13. GUCN Central Loose Tube Cables Universal Indoor / Outdoor - Corrugated Steel Tape Armor (CST) A/I-DQ(ZN)(SR)H Full Rodent Protection 07-07-05 v3.0 Ordering Information Belden Part Numbers Fibre Description

More information

Multi-Core Fire Resistant Cable

Multi-Core Fire Resistant Cable Fire Resistant Cables / Multi-Core Fire Resistant Cable Approved to UL 444, Zeta ZFP series cables have received UL approval for standard applications. Standards Alarm Cable Z UL 444 Approval CMH Rated

More information

Table of Contents. TELE-FONIKA KABLE SA (DMCC Branch). 4 TELE-FONIKA Kable Group 6 FLAME-X 950 SERIES 1 11 FLAME-X 950 SERIES 2

Table of Contents. TELE-FONIKA KABLE SA (DMCC Branch). 4 TELE-FONIKA Kable Group 6 FLAME-X 950 SERIES 1 11 FLAME-X 950 SERIES 2 FLAME-X 950 TELE-FONIKA KABLE SA (DMCC Branch). Table of Contents is the Regional Middle East Sales Office of Tele-Fonika Kable S.A. from Poland, 4-th largest manufacturer of electric cables and wires

More information

Power Cables. Introduction 3 RV 4 RVMV 5 RVSV 6 RVFV 7. ELECWIRES 2 Page

Power Cables. Introduction 3 RV 4 RVMV 5 RVSV 6 RVFV 7. ELECWIRES 2  Page Power Cables Power Cables Page Introduction 3 RV 4 RVMV 5 RVSV 6 RVFV 7 ELECWIRES 2 www.elecwires.es INTRODUCTION Power Cables Power cables for electrical installations, domestic & industrial, specifically

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Presley House Presley Way Crownhill Milton Keynes MK8 0ES United Kingdom Contact: Jeremy Hodge Tel: +44 (0) 1908 267300 Fax: +44 (0) 1908

More information

Havells Fire Survival Cables

Havells Fire Survival Cables Fire Survival Cables Designed for Critical Installation of National Importance Airports / Thermal Power Plants Metro Rail Projects / Rail Terminals / Nuclear Interstate Bus Terminals / Installation Prone

More information

FIRE RESISTANT CABLES FP PLUS. New Generation. Now with enhanced Insudite TM insulation

FIRE RESISTANT CABLES FP PLUS. New Generation. Now with enhanced Insudite TM insulation FIRE RESISTANT CABLES FP PLUS New Generation Now with enhanced Insudite TM insulation ENHANCED FIRE RESISTANT CABLES FP PLUS BS7629-1:2008 FP PLUS > Certificate No 077g/02 The new generation of FP PLUS

More information

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red Indoor/Outdoor steel tape armoured (CST) double LSHF-FR sheathed optical cable with 2 24 fibres. VDE: A/I-DQ(ZN)H(SR)H 3rd party verification of the fire tests by BUREAU VERITAS December 2014 OFC-UT-CST

More information

OFFSHORE CABLES. Top Cable Central Headquarters. Leonardo Da Vinci, number Rubí (Barcelona) Spain

OFFSHORE CABLES.   Top Cable Central Headquarters. Leonardo Da Vinci, number Rubí (Barcelona) Spain Top Cable Central Headquarters Leonardo Da Vinci, number 1 08191 Rubí (Barcelona) Spain OFFSHORE CABLES Tel +4 9 586 21 78 +4 9 586 21 68 Fax +4 9 586 21 65 sales@topcableoffshoremarine.com http://www.topcableoffshoremarine.com

More information

Total Fire Solutions. Includes BS 8519 and the updated BS :

Total Fire Solutions. Includes BS 8519 and the updated BS : Total Fire Solutions Includes BS 8519 and the updated BS 5266-1:2011 www.aeicables.co.uk Introduction: Total Fire Solutions Power and control cable systems for life safety and fire-fighting applications

More information

FIRE RESISTANT CABLES FP300

FIRE RESISTANT CABLES FP300 FIRE RESISTANT CABLES FP300 Fire resistant LSOH power cables for fixed wiring FIRE RESISTANT CABLES FP300 LPCB Ref No: 077e/01 FP300 > Prysmian FP300 is designed for cabling essential safety circuits associated

More information

Catalogue Power Cables

Catalogue Power Cables Catalogue Power Cables Conductores Tecnológicos S.A. www.contecsa.es Index of Cables Page Introduction 13 RV 14 RVMV 15 RVSV 16 RVFV 17 Conductores Tecnológicos S.A. 2 www.contecsa.es INTRODUCTION Power

More information

FIRE RESISTANT CABLES FP200 GOLD

FIRE RESISTANT CABLES FP200 GOLD FIRE RESISTANT CABLES FP200 GOLD FIRE RESISTANT CABLES FP200 GOLD BS7629-1 FP200 GOLD Clause 26.2 > The original highly durable and dressable, easy to terminate and install fire resistant cable. Approved

More information

Shipboard & Offshore Cables

Shipboard & Offshore Cables Shipboard & Offshore Cables Shipboard & Offshore Cables Páge Introduction 3 Power Cables XL / XL-FR 5 XC4L / XC4L-FR 6 XLC4L / XLC4L-FR 7 Instrumentation cables XHL / XHL-FR 8 XOL / XOL-FR 9 XHC4L / XHC4L-FR

More information

MEDIUM VOLTAGE CABLES INSTRUMENTATION CABLES RUBBER CABLES FIRE RESISTANT CABLES

MEDIUM VOLTAGE CABLES INSTRUMENTATION CABLES RUBBER CABLES FIRE RESISTANT CABLES RUBBER CABLES FIRE RESISTANT CABLES INSTRUMENTATION CABLES MEDIUM VOLTAGE CABLES Halley Cables, established in 2006, is a dynamic company, specialized in power supply, which focuses on customers satisfaction.

More information

(Notices) EUROPEAN COMMISSION

(Notices) EUROPEAN COMMISSION 14.8.2012 Official Journal of the European Union C 245/1 IV (Notices) NOTICES FROM EUROPEAN UNION INSTITUTIONS, BODIES, OFFICES AND AGENCIES EUROPEAN COMMISSION Commission communication in the framework

More information

The Quality Connection. BETAflam Safety cables for highest demands

The Quality Connection. BETAflam Safety cables for highest demands The Quality Connection BETAflam Safety cables for highest demands 2 For solutions that will still be standard tomorrow. BETAflam Safety cables Thanks to their proven quality, BETAflam safety cables are

More information

INTRODUCTION. Our diverse range of world-class Specialty Insulated Wires and Cablesinclude: LV Cables -

INTRODUCTION. Our diverse range of world-class Specialty Insulated Wires and Cablesinclude: LV Cables - MARINE CABLES Your Power Partner on the Seas INTRODUCTION We, a member of the Al-Bahja Group of Companies, are an ISO:900:2008 BASEC, UK certified integrated quality producer of LV and MV Cables, Wires&

More information

Tratos Railway Cables

Tratos Railway Cables January 2013 Tratos Railway Cables Cables for a moving world www.tratos.eu Introduction Tratos Cavi is a company specialising in the production of power, signalling, control and telecommunications cables

More information

FIRE RESISTANT CABLES FP400

FIRE RESISTANT CABLES FP400 FIRE RESISTANT CABLES FP400 FIRE RESISTANT CABLES FP400 BS7846-F2 CABLE CHARACTERISTICS FP400 APPROVALS INSTALLATION Certificate No 077b Certificate No 517b > Prysmian FP400 is the original fire resistant

More information

HELKAMA. Optical Fibre Cables

HELKAMA. Optical Fibre Cables 1 Contents Optical fibres and their characteristics Cable constructions Cable tests Installation, jointing and terminating Manufacturing (pictures) 2 Multimode Fibre (GK) Attenuation and Bandwidth Fibre

More information

CONTENTS. Introduction Customer Service BS codes of practice BS Fire Performance Cable Selection Guide... 7

CONTENTS. Introduction Customer Service BS codes of practice BS Fire Performance Cable Selection Guide... 7 CONTENTS Page Introduction... 1 Customer Service... 2 BS codes of practice BS 8519... 5 Fire Performance Cable Selection Guide... 7 FlamBICC Introduction...8 FlamBICC 1...10 FlamBICC 2...12 FlamBICC 3...14

More information

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red OFC-UT-CST Fire resistant Armoured Indoor/Outdoor steel tape armoured (CST) double LSHF-FR sheathed optical cable with 2 24 fibres. VDE: A/I-DQ(ZN)H(SR)H 3rd party verification of the fire tests by BUREAU

More information

Caledonian. FIREFLIX ire Resistant Coaxial Cables

Caledonian. FIREFLIX ire Resistant Coaxial Cables Caledonian FIREFLIX ire Resistant Coaxial Cables table OF COntents Fire resistant Coaxial Cables Fire Resistant RG59 B/U coaxial cables...25 Fire Resistant RG6 A/U coaxial cables...28 Fire Resistant RG6

More information

13. UNITED KINGDOM Standards Supply Voltage and Plug Configurations 247

13. UNITED KINGDOM Standards Supply Voltage and Plug Configurations 247 13. UNITED KINGDOM 13.1 Standards 13.1.1 BSI 240 13.1.2 BASEC 242 13.1.3 BBC 242 13.1.4 BNFL 242 13.1.5 BRB 242 13.1.6 British Telecom 243 13.1.7 Department of the Environment 243 13.1.8 Department for

More information

Agencavi Srl has been specializing in the distribution of special cables and accessories for industrial automation since 1983.

Agencavi Srl has been specializing in the distribution of special cables and accessories for industrial automation since 1983. About us Agencavi Srl has been specializing in the distribution of special cables and accessories for industrial automation since 1983. Product quality is an essential element for ensuring the efficiency

More information

FIRE RESISTANT CABLES FP200 GOLD

FIRE RESISTANT CABLES FP200 GOLD FIRE RESISTANT CABLES FP200 GOLD FIRE RESISTANT CABLES FP200 GOLD BS7629-1:2008 FP200 GOLD FIRE RESISTANT CABLES Key Applications Fire detection and fire alarm systems for buildings Voice alarm systems

More information

Compact Module. Category 6A FTP Cabling System 1.1

Compact Module. Category 6A FTP Cabling System 1.1 Updated 24/09/12 Compact Module Cat 6A performance Suitable for 10-Gigabit Ethernet Ultra-slimline design Euro style module Interchangeable with other Euro Modules and blanks Individually QA tested Easy

More information

All Prysmian FP400 cables are manufactured under an ISO 9001 Quality System certified by BASEC and LPCB.

All Prysmian FP400 cables are manufactured under an ISO 9001 Quality System certified by BASEC and LPCB. Certificate No 077b Certificate No 517b > Prysmian FP400 is the original fire resistant armoured cable providing an easy to install and terminate, robust fire resistant wiring system. In addition to maintaining

More information

LSOH Flexible Cables

LSOH Flexible Cables LSOH Flexible Cables Low Voltage (300/500 V) 3182B, 3183B, 3184B Piresafe TM Flex Cable Approvals Key Applications > Supply leads for medium duty domestic and office appliances, lighting fittings and portable

More information

CMZH Low Smoke 0-Halogen Flame- Retardant Mass Transit Tag

CMZH Low Smoke 0-Halogen Flame- Retardant Mass Transit Tag STANDARD COLOR CMZH Low Smoke 0-Halogen Flame- Retardant Mass Transit Tag TECHNICAL DATA SHEET Revision Number. 1 Last Edited 9. januar 2019 OTHER COLORS MATERIAL Flat band cross linked polyolefin. OPERATING

More information

Easy to install in ducts, tunnels and trenches by means of compressed air or pulling wire. Suitable for direct burial (crush 400 N/cm).

Easy to install in ducts, tunnels and trenches by means of compressed air or pulling wire. Suitable for direct burial (crush 400 N/cm). GCDG Multi Loose Tube Cables Universal Indoor / Outdoor - Corrugated Steel Tape Armor (CST) A/I-DQ(ZN)H(SR)H Full Rodent Protection Ordering Information Belden European Part Numbers Fibre type / count

More information

Rolling Stock Cables.

Rolling Stock Cables. Rolling Stock Cables www.caledonian-cables.co.uk www.addison-cables.com & Addison, established in 1978, produced a wide range of copper and fiber optic cables for communication, power and electronics in

More information

CORRIGENDA. (Publication of titles and references of harmonised standards under Union harmonisation legislation)

CORRIGENDA. (Publication of titles and references of harmonised standards under Union harmonisation legislation) C 173/162 EN Official Journal of the European Union 13.5.2016 CORRIGENDA Corrigendum to Commission communication in the framework of the implementation of Directive 2006/95/EC of the European Parliament

More information

Multipurpose Cables (indoor/outdoor), Multipurpose central tube cable (maxibundle) with glass yarn armouring A-DQ(BN)H 4-24

Multipurpose Cables (indoor/outdoor), Multipurpose central tube cable (maxibundle) with glass yarn armouring A-DQ(BN)H 4-24 Features and Benefits Laminated swelling glass yarns Improved rodent resistance and longitudinal water protection UV and microbe resistant Can be directly buried or installed in ducts Metal-free cable

More information

Industrial Fiber Optic Cables, LSZH Corrugated Armored Cable, Fibers

Industrial Fiber Optic Cables, LSZH Corrugated Armored Cable, Fibers Features and Benefits Corrugated armor Mechanical protection Low-smoke/zero-halogen (LSZH ) sheath Key life-safety benefit Meets cyclic impact and chemical resistance test Superior performance Tray-rated

More information

UNIKA Universal Cable Cable Specialist

UNIKA Universal Cable Cable Specialist UNIKA Universal Cable Cable Specialist Committed to Quality At ÜNİKA, quality is an intrinsic part of our Operations. Our comprehensive product and System certification not only are mandatory requirements

More information

Fire Resistant Cables

Fire Resistant Cables Fire Resistant Cables Ducab (Abu Dhabi) Factory P.O. Box 9171, Abu Dhabi, UAE Tel: (971-2) 502 7777 Fax: (971-2) 502 7888 email: ducab@ducab.com Ducab Connect P.O. Box 11529, Dubai, United Arab Emirates

More information

Data sheet OpDAT breakout cable 12x1 OM4 - bend insensitive, class Dca s1 d1 a1

Data sheet OpDAT breakout cable 12x1 OM4 - bend insensitive, class Dca s1 d1 a1 Page 1/9 Illustrations Principle diagram See enlarged drawings at the end of document Product specification connection cable I-V(ZN)HH breakout cable for direct connector termination for indoors and outdoors

More information

GCRG. Multi Loose Tube Cables Universal Indoor / Outdoor A/I-DQ(ZN)BH Improved Rodent Protection v7.0. Ordering Information.

GCRG. Multi Loose Tube Cables Universal Indoor / Outdoor A/I-DQ(ZN)BH Improved Rodent Protection v7.0. Ordering Information. GCRG Multi Loose Tube Cables Universal Indoor / Outdoor A/I-DQ(ZN)BH Improved Rodent Protection 05-05-7 v7.0 Ordering Information Belden Part Numbers Fibre Description / count 4 8 8 4 30 36 6.5/5-OM GCRG04

More information

THE INNOVATIVE CABLE PRODUCER INSTRUMENTATION CABLES FOR THE INDUSTRY - AND PLANT CONSTRUCTION

THE INNOVATIVE CABLE PRODUCER INSTRUMENTATION CABLES FOR THE INDUSTRY - AND PLANT CONSTRUCTION THE INNOVATIVE CABLE PRODUCER INSTRUMENTATION CABLES FOR THE INDUSTRY - AND PLANT CONSTRUCTION About Us 60 Countries Using Birtaş Cable Products As of 2014 Birtaş Kablo is exporting its products to 60

More information

(Publication of titles and references of harmonised standards under Union harmonisation legislation) (Text with EEA relevance) (2017/C 298/02)

(Publication of titles and references of harmonised standards under Union harmonisation legislation) (Text with EEA relevance) (2017/C 298/02) C 298/14 EN Official Journal of the European Union 8.9.2017 Commission communication in the framework of the implementation of Directive 2014/35/EU of the European Parliament and of the Council on the

More information

Single core cables with reduced wall thickness

Single core cables with reduced wall thickness Product description: RADOX 4 GKW -AX 1800V M Nominal voltage: Hazard level: Single core cables with reduced wall thickness 1800 / 3000 V AC M (extra low temperature, extra oil and extra fuel resistant)

More information

DNVGL-CP-0399 Edition March 2016

DNVGL-CP-0399 Edition March 2016 CLASS PROGRAMME Type approval DNVGL-CP-0399 Edition March 2016 The electronic pdf version of this document, available free of charge from http://www.dnvgl.com, is the officially binding version. FOREWORD

More information

CORFLEX. TYPE MC-HL & MV-105 or MC-HL OIL & GAS CABLES

CORFLEX. TYPE MC-HL & MV-105 or MC-HL OIL & GAS CABLES CORFLEX TYPE MC-HL & MV-105 or MC-HL OIL & GAS CABLES INDEX Instrumentation Cables - Pairs and Triads (0V*)... 2 - The Original MC-HL Technology In 1958 Canada Wire and Cable, which s now part of Nexans,

More information

SOLAR CABLES. Electric cables for solar PV installations

SOLAR CABLES. Electric cables for solar PV installations SOLAR CABLES Electric cables for solar PV installations TOP CABLE Top Cable is an internationally recognized manufacturer of electric cables, and is highly thought of by professional Engineers & Electricians

More information

outdoor and indoor campus backbone, building backbone (riser) FDDI, Gigabit Ethernet and ATM Easy to install direct burial halogen-free

outdoor and indoor campus backbone, building backbone (riser) FDDI, Gigabit Ethernet and ATM Easy to install direct burial halogen-free GUSN Central Loose Tube Cables (Distribution) Universal Indoor/ Outdoor A/I-DQ(ZN)BH Standard Rodent Protection 05-04-8 v0.0 Ordering Information Belden Part Numbers Fibre Description / count 4 6 8 6 4

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 61156-6 First edition 2002-03 Multicore and symmetrical pair/quad cables for digital communications Part 6: Symmetrical pair/quad cables with transmission characteristics up

More information

Author Owner Issue Authority Name: Gordon MacKenzie Title: Senior Engineer Engineering Design and Standards

Author Owner Issue Authority Name: Gordon MacKenzie Title: Senior Engineer Engineering Design and Standards 1. SCOPE This Specification details requirements for General Wiring cables up to and including 450/750V for use on lighting and general power wiring installations complying with BS 7671 but not forming

More information

Copper LAN cable. This specification describes the general requirements for AMP NETCONNECT* copper LAN cable.

Copper LAN cable. This specification describes the general requirements for AMP NETCONNECT* copper LAN cable. Product Specification 108-93018 25/Aug/2011 Rev H Copper LAN cable 1. SCOPE 1.1. Content This specification describes the general requirements for AMP NETCONNECT* copper LAN cable. 2. APPLICABLE DOCUMENTS

More information

Ø 1000 * 588 mm 50 kg

Ø 1000 * 588 mm 50 kg GUCN Central Loose Tube Cables Universal Indoor / Outdoor - Corrugated Steel Tape Armor (CST) A/I-DQ(ZN)(SR)H Full Rodent Protection Ordering Information Belden European Part Numbers Fibre type / count

More information

Fire Alarm/Life Safety Cable 6

Fire Alarm/Life Safety Cable 6 Electronics Fire Alarm/Life Safety 6 Index Page Alarm and Security Solutions Guide 114-116 Fire alarm systems have expanded from a rather simple and unsophisticated business configured upon large, electromechanical

More information