3 Safety cable systems Halogen-free safety cables with reference to VDE H05Z-K, H07Z-K / U / R 22 NHXMH, (N)HXM(St)H 26 N2XH, N2XCH 30 J-H(St)H 42 J-H(St)H Brandmeldekabel 44 Halogen-free safety cables with circuit integrity Fire alarm cables Standard/Enhanced from page 46 FE180 from page 54 Support systems / Cable ducts Cable ducts I30, type Hermannkanal 94 WUM (support measure) 95 Fixing devices Single clamps, type SAS, SAS V4A 100 Strap clamps, type B without trough (LW) 101 Strap clamps, type B with trough (LW) 102 Fire stop systems Fire stop systems, plates 104 Fire stop systems, plugs/accessories 105 Cable joints E30/E Connection/terminal boxes 108 E0 multi-cable supports 111 Fire protection plugs / accessories from page 112 Fire protection screws 114 Colour codes in accordance with VDE, CENELEC and SEV standards 121 E30-E90 support systems 122 Compendium of standards 123 Halogen-free safety cables with circuit integrity and system circuit integrity with reference to VDE (N)HXH, (N)HXCH FE180 E30-E60 from page 64 (N)HXH, (N)HXCH E90 from page 74 JE-H(St)H / HRH FE 180 E30L / E30-E90 from page 80 Brandmeldekabel FE180 E30-E90 from page 84 Fibre optic safety cables from page 90 Wire mesh cable trays / accessories from page 96 Cable trays / accessories from page 98 Multi cable support E30-E E Emergency lighting 110 Armoured conduits from page 115

4 Datwyler A reliable partner at your side Convincing every time, everywhere The life blood of a modern public or commercial building is the functionality and reliability of the system solutions for communications, building automation, power supply, safety and lifts. This is true of any such construction, irrespective of whether it is an office block, hotel, sports stadium, television studio or a tunnel. Choose a reliable system partner right from the start. Hotels, hospitals Office blocks Parliament buildings, universities Shopping centres Data centres Tunnels Datwyler

5 Choose Datwyler! Datwyler is a highly regarded company about to celebrate its 100th year of operation. With the backing of a financially powerful group, Datwyler operates on the international stage as a successful supplier of total solutions for the electrical and communications infrastructure of buildings and for FTTx networks. We lead the way in innovations for applications such as information and communications technology, power supply and safety, building automation and lifts. Event arenas Our systems are reliable and constitute a secure investment on your part. This is all thanks to the years of experience and proven expertise of our engineers and technicians. Datwyler is a one-stop source of customised solutions for all your specific applications as attractive total solutions, with all the necessary test certificates, authorisations and approvals and with long-term warranties. Our workforce prides itself on delivering a full package of services for all the products and solutions supplied by the company. You can rely on our expert support for all aspects of our supply beginning with planning, consultancy, through pre-assembly, logistics, installation and ending with system maintenance. FTTx projects Datwyler

6 Datwyler Worldwide expertise in turnkey creation, multi-site projects and services Turnkey installations Maintenance Communication Energy Advice Electrical and communications infrastructure Datwyler does not only supply integrated total solutions, but has positioned itself successfully as a turnkey partner: for all manner of purpose-built constructions including multi-site projects and for FTTx projects. Our successful processing of turnkey projects derives from our highlevel skills in developing and manufacturing the required products and solutions, our comprehensive applications expertise and the international scope of Datwyler activities. Safety Building automation Implementation Planning Our international presence and our worldwide, actively managed and certificated partner network have also proved invaluable in the multi-site projects of major clients. National and international companies rely on Datwyler on-the-spot site audits. Using the site audits as a base, our engineering experts work out customised solutions with uniform standards for all the sites concerned. Our total solutions package is rounded off by the implementation and assurance of regular operations. While operations are running, we provide servicing and maintenance work to optimise your infrastructure solution. These MAC (move, add, change) services increase the performance and working life of your equipment. Of course, all our processes are ISO /14001 certified. Opt for sustainable solutions that provide you with high-level operational reliability coupled with low operating costs. The proof that Datwyler systems can deliver these benefits has been evident for many years in thousands of installations around the world. In addition, we have a particularly keen eye for consistent, intelligent solutions that simplify planning, sourcing and installation and shorten your construction times. We have the right total solutions for all your applications, whatever they are high-speed communications networks, modern energy distribution, monitoring and control duties, fire alarm systems or lift cabling. Or you may want to integrate new systems, interconnect and automate existing systems or simply ensure a reliable power supply. All this is possible with our carefully thought out, pre-assembled and prefabricated subsystems. High-quality solutions for all your applications Year on year, Datwyler invests in even better materials and process technologies, production resources and test methods. This is why our system solutions always keep ahead of the current norms and repeatedly set new standards. The important functions which our solutions must deliver in practice demand the highest possible level of safety and reliability. This is why we measure each product against stringent quality standards before it leaves the company. Just tell us how, when and where Besides quality and product price, the logistics performance capability of suppliers is a decisive factor in the successful handling of construction projects. This is particularly true of major projects. With its years of experience and high logistics competences, Datwyler can handle even time-critical major projects smoothly and to the complete satisfaction of customers. Just-in-time deliveries at the right place are all in a day s work for us and our partners. Datwyler

7 Besides delivering straight to the construction site, we also offer you additional logistics services (time slots, pre-fitted and pre-assembled products etc.). Many customers and suppliers have a direct link to our IT system for rapid and flexible order processing. As regards cable pre-assembly, Datwyler also has wide-ranging expertise, the product of decades of experience. In our modern cable cutting centre, the engineering department passes the cutting orders electronically without any media discontinuity straight to the production area. Our efficient order communication system with all our customers is due to years of experience with B2B interfaces. In the growth markets of Eastern Europe and the Middle East we opened a branch recently. In many countries Datwyler works in close co-operation with independent distribution partners. Thus our customers can rely on the consistently high quality standard of all Datwyler products and solutions whilst benefiting from local contacts and logistics services. We support you in realising your infrastructure project reliably, capably, complete and with the highest quality! Datwyler

8 Connections that work in case of fire Safety cable systems Datwyler

9 Whether in football stadiums, airports or metro stations wherever masses of people assemble in a confined space, the risk of catastrophe in case of fire is especially great. That s why special cabling systems are particularly important systems that continue to function dependably even during a fire providing lifesaving security for an extended time. As a leading provider of safety cable systems, Datwyler closely collaborates with fire-protection specialists to develop innovative solutions. These systems provide continuous power and data transmission even in a fire, and thus form the backbone of an effective fire-safety concept. Mobility is increasing rapidly worldwide and with it the sizes of crowds in airports and train stations. Other confined spaces in which thousands of people congregate daily include office towers, shopping centres, event arenas and entertainment parks. Safety standards meet cable technology Fire-safety regulations are being continually tightened to minimise fire damage and provide the best possible protection of life and property. Datwyler is a step ahead in the race, offering innovative total solutions that incorporate electrical cable systems with extended functional integrity. These systems go beyond the toughest European norms. Functional integrity testing covers not just individual cables but complete cable systems including the associated supports and fasteners. In contrast to conventional insulation integrity testing, this method of comprehensive testing reflects the actual performance of entire cable systems installed in a buildings that catches on fire. Patented ceramic technology Datwyler has been producing safety cables using patented ceramic technology for over ten years. The materials and processing of the ceramic-insulated products are being constantly improved. The latest generation of cables offers a variety of tested, standard-compliant installation options that outperform by far the conventional installation methods (in accordance with DIN ). Datwyler

10 Added value for fire-safety systems Safety cable systems Leading know-how As a provider of total solutions for safety cable systems, Datwyler possesses comprehensive know-how accumulated over decades: - Co-development of extended functional integrity tests in collaboration with renowned testing institutes in the early 1990s. - Sound knowledge of safety engineering and building codes and standards. - Leading material, production and process know-how in the fabrication of safety cables incorporating patented and proven ceramic technology. - Development of the first metal-free fibre-optic cable with E30 extended functional integrity through combining existing technical competence in data and safety cable engineering. - Broad systems competence. - Collaboration with renowned technical universities, international standard committees and independent testing institutes. Diverse applications Datwyler safety cable systems with extended functional integrity are used wherever stringent fire-safety requirements must be met and people and property could be at risk due to fire and smoke: - Airports, train stations, metro stations - Hotels and hospitals - Sports stadiums, theatres and concert halls - Office and exhibition buildings, public buildings - Tunnels for road and rail Datwyler

11 System solutions - The pyrofil cable line includes halogen-free, low-smoke emission and flame resistant safety cables with circuit integrity and functional integrity. - The Safety product line includes support systems, mounting components and appropriate accessories to ensure functional integrity. - Our FO are the first metal-free fibre-optic cables with E30 extended functional integrity with reference to DIN Fire protection seminars and special calculation programmes offer engineers and installers valuable support - Comprehensive services up to and including turnkey and multi-site projects Galeria Krakowska, Krakow Selected reference projects Allianz Arena Munich Trade Fair Stuttgart Dexia BIL Luxembourg Reichstag Berlin International Airport Frankfurt Subway Munich World Trade Center Dubai Metro Prague Galeria Krakowska Krakow Gotthard motorway tunnel Gotthard New main station (Lehrter Bahnhof ) Berlin Mercedes Benz Museum Stuttgart Crystal Plaza Towers United Arab Emirates Customer value in focus Datwyler stands for more than the production and distribution of products. For your safety cabling systems we provide everything from one source: modular system solutions with high-quality cables and components, with all the necessary test certificates and authorisations and with long-term warranties. You can rely on our expert support for all aspects of our supply beginning with planning, consultancy, through logistics, installation and ending with system maintenance. The interaction of these elements creates added value. As a customer you benefit from cost-effective installation thanks to our innovative installation methods, sign-off without any difficulties, low insurance rates, and dependable transmission of power and data even in the event of fire. Crystal Plaza Towers, United Arab Emirates Datwyler

12 Safety concepts for buildings Proven quality Datwyler is the first European manufacturer to develop a complete system solution that meets the demands of today s industry for reliable power supply and data transmission in the event of fire. pyrofil cables and our approved cabling system components are the result of many years of intensive development in coordination with the relevant standardisation bodies. Selected raw materials and special compounds in combination with unique installation methods are what give a Datwyler system its high quality and maximum guaranty of safety in the event of fire. pyrofil cables and Datwyler safety system components are used wherever people, machinery and equipment are endangered by fire and smoke emission: in buildings with high density of occupants as well as in facilities containing large concentrations of valuable property. Our safety cable systems have to be highly reliable when it comes to practical operations. This is why Datwyler measures each and every product against strict quality standards before it leaves the company. Specifically, this means that all processes are integrated into the comprehensive management system in accordance with ISO 9001 and ISO Beyond this, additional application-specific inspection and test methods ensure that pyrofil cables and Datwyler safety cable systems exceed the requirements of our customers as well as the stringent standards specified by the various countries in which our products are used. Steel conduits and halogen-free plastic conduits from page 115 Fire protection plugs F90 Installation depth 30mm from page 112 Single clamps type SAS Spacing 600mm page 100 Strap clamps without trough type B Spacing 800mm page 101 Strap clamps with trough type B Spacing 800mm page 102 Gas concrete plugs F90 from page 112 Screws F90 from page 114 Identification signs page 104 S90/S120 Plates/Mortar /Bricks/Plugs from page Datwyler

13 pyrofil Safety cable E90 Keram from page 74 pyrofil E90 Keram from page 74 WUM Support measure from page 95 Modular shaft lighting system pyrofil E30-E60 Keram from page 64 Flat form cable with integrated data bus Cable joints E30 and E90 for all dimensions page 106 Elevator travelling cables Fibre optic safety cable, with reference to DIN , 30 Min. page 82 Distribution box E30-E90 type Hercules page 107 Cable trays and cable ladders E30/E90 Spacing 1500mm page 96 Connection/terminal box E30-E90 page 108 Multi cable support Hermanschelle E30/E90 Spacing 600/800mm page103 Datwyler 11

14 Safety concepts for tunnels Steel conduits and halogen-free plastic conduits from page 115 Fire protection plugs F90 Installation depth 30mm from page 112 pyrofil E30-E60 Keram from page 64 Identification signs page 104 Single clamps type SAS V4A Spacing 600mm page 100 Gas concrete plugs F90 from page 112 Screws F90 from page 114 E30/E90 from page 108 Cable trays and cable ladders E30/E90 Spacing 1500mm page96 Multi cable support Hermanschelle E30/E90 Spacing 600/800mm page 103 Flat form cable with integrated data bus 12 Datwyler

15 pyrofil E30/E90 Keram from page 64 Fibre optic safety cable with reference to DIN , 30 Min. page 82 Cable joints E30 and E90 for all dimensions page 106 Distribution box E30-E90 type Hercules page 107 Strap clamps without trough type B Spacing 800mm page 101 Strap clamps with trough type B Spacing 800mm page 102 pyrofil E30-E90 Keram from page 64 Emergency lighting for escape routes page 110 S90/S120 Plates/Mortar/Bricks/Plugs from page 104 Fibre optic safety cable with reference to DIN , 30 min. page 82 Datwyler 13

16 Cable technology for highest safety requirements Cable Applications Product range/standards with extended functional integrity Low voltage cables up to 0.6/1 kv E30-E90; FE180; BS 6387 CWZ; PH30-120, Rf / 2 with mechanical protection from page P-56 with circuit integrity and extended functional integrity to maintain power supplies to sprinkler systems, emergency lighting, smoke and heat extraction systems, emergency lift supplies and fire fighting lifts. Single core cables from 1.5 to 630 mm 2 Multi core cables from 1.5 to 300 mm 2 Also available with mechanical protection Standards/Approvals IEC, EN, CENELEC, BS, DIN VDE, SEV, NBN, VKF, VdS, GOST-R, Ukraine Wiring and fire alarm cables up to 225 V E30-E90; FE180; BS 6387 CWZ; PH30-120, Rf / 2 ANDMELDEKABEL with mechanical protection from page P-72 with circuit integrity and extended functional integrity to maintain power supplies and data transmission to fire alarm systems, public address and voice alarm systems. Single or multi pair cables, individually or collectively screened. Also available as fire alarm cable and with mechanical protection. Standards/Approvals IEC, EN, CENELEC, DIN VDE, SEV, NBN, GOST-R Fibre-optic safety cables with reference to DIN min. (E30); IEC Universal fibre-optic cables for indoor and outdoor applications. Loose tube construction with up to 60 SM-/MM-fibres with non-metallic rodent protection. Standards/Approvals IEC, EN, CENELEC, DIN VDE from page P-82 with circuit integrity Fire alarm cables 300/500 V BS 6387 CWZ; FE180; BS , EN (PH ) and Annex E with mechanical protection from page P-34 with circuit integrity to maintain power supplies and data transmission to fire alarm systems, emergency lighting, public address and voice alarm systems. Screened multi core cables from 1.0 mm 2 to 4 mm 2. Also available with mechanical protection. Standards/Approvals BS, EN, CENELEC, LPCB, GOST-R with improved characteristics in case of fire Low voltage cables up to 0.6/1 kv with improved characteristics in case of fire an alternative to traditional PVC cables, where no circuit integrity is required. Single core cables from 1.5 to 630 mm 2 Multi core cables from 1.5 to 300 mm 2 Also available with mechanical protection and as flexible, oil resistant version. from page P-22 Standards/Approvals IEC, EN, CENELEC, DIN VDE, SEV, GOST-R 14 Datwyler

17 System compatible installation components System components Application Single clamps, multi cable supports Single clamps to install single cables or cable bundles conforming to common practice. Multiple cable supports for a cost effective installation of several cables. from page P-92 These components facilitate the quick and easy retrospective/subsequent installation of cables. Support systems from page P-88 from page P-105 Special support systems to install several cables conforming to common practice. Approved for ceiling and wall mounting with possibility of easy retrospective/subsequent installation of cables. Corresponding fixing devices, such as fire safety dowels, installation screws and setting tools are available for all support systems. Connecting technology Cable joints to connect pyrofil safety cables with circuit and extended functional integrity. with extended functional integrity E30-E90. Also available as fire resistant covers to protect standard connections or junction blocks. from page P-99 with circuit integrity for high- and low-voltage cables. from page P-96 S90/S120 - Firestop coated board S100 P - Intumescent firestop paint S100 D - Intumescent firestop mastic S100 SM-K - Firestop bricks TS 90 - Firestop plugs TS 90 Seminars Datwyler is setting new standards. pyrofil safety cables combined with Datwyler system components make up the perfect and cost effective safety solution. For further information please visit Datwyler regularly holds seminars on cabling systems with integrated circuit and extended functional integrity as well as on firestop systems. Datwyler 15

18 Product features The illustrated pictograms show the essential product features and give an easy reference. They are allocated to the articles on the data sheets and provide you with a quick overview Zero halogen, non corrosive gases Datwyler cables are halogen-free and reduce possible damage to health or material to a minimum. IEC and IEC , EN , EN , EN VDE part 2-1, 2-2 and 2-3 Flame propagation Datwyler cables use a high performance, flame retardant material that is self extinguishing. IEC , EN , VDE Flame spread Datwyler cables are flame resistant and prevent the propagation of a fire from one location to another IEC to 25 cat. A-D, EN bis 25 cat. A-D, VDE to 25 cat. A-D Smoke density Datwyler cables emit minimum smoke in the event of fire. Exit routes and fire brigade access are not restricted. IEC and IEC , EN and EN , VDE part 1 and 2 Circuit integrity [FE/PH] Datwyler cables with circuit integrity guarantee the function of a single cable for a defined duration. (FE is for flame time and influence time) IEC , IEC and part 21,23, 25, EN with Annex E, EN 50362, VDE 0472 part 814, VDE , VDE , BS , BS 6387 (cat. C/W/Z) System Circuit integrity [E30-E90] Datwyler cables and the licensed fixing systems guarantee the function of the complete electrical cable installation for a defined time. (E30=30 minutes, E60=60 minutes, E90=90 minutes) DIN 4102 part 12 [E30-E90] NBN (Rf1, Rf1½) 16 Datwyler

19 The most important test procedures and their functions Test on gases evolved during combustion This test procedure provides information if the insulation material of the cable sheath creates corrosive gases in the event of fire. Halogen parts or other material in small quantities can be easily identified with this test due to the strong change of ph and conductivity. The conductivity is < 10mS/mm Standards - IEC and IEC EN , EN EN VDE part 2-1, 2-2 and 2-3 Test for vertical flame propagation (single insulated wire or cable) This test method tests a 60 cm long cable sample for burning behaviour. The flame must extinguish itself and the burn damage must not reach the upper end of sample. Standards - IEC EN VDE Test for vertical flame spread (bunched wires or cables) This test method tests a 360 cm long cable bundle with regard to fire propagation. The flames must extinguish themselves and burn damage must not exceed a defined height. Standards - IEC up to 25 Cat A-D - EN up to 25 Cat. A-D - VDE up to 25 Cat. A-D Measurement of smoke density This test checks smoke development when burning the cable or the impairment of the visibility by burning cables. The reduction in light transparency is measured in a standard chamber. Standards - IEC and IEC EN and EN VDE part 1 and 2 Datwyler 17

20 The most important test procedures and their functions Test of circuit integrity (FE/PH) This test establishes whether a single cable can maintain circuit integrity during and after exposure to a fire for a time period of at least 180 minutes. Cables which fulfil the requirements of this test are marked with FE180 after their type designation. There is no obligation to test the cable for functional integrity beyond the designated period. Remark: This test is not equivalent to the test for functional integrity in accordance with DIN Test of Circuit integrity (Fire and water) - BS 6387 (cat.w) [650 C, 3A] - VdS 3423 [>830 C, 3A] - EN Annex E [>830 C, 2A] Test of Circuit integrity (Fire and mechanical shock) - IEC /-2 [>830 C, 2A] - EN (PH) [>830 C, 2A] - EN [> 830 C, 2A] - BS 6387 (cat.z) [950 C, 3A] Test of Circuit integrity (Fire alone) - IEC /-21/-23/-25 [>750 C] - BS 6387 (cat. C) [950 C] - VDE [>750 C] Test of System Circuit integrity of electrical cable installations This standard describes the requirements and the actions for the achievement of the functional integrity of complete electrical cable installations in the event of fire. While the circuit integrity FE provides only for the test of single cables, the cables here are tested in connection with practical fixing systems. It is important to appreciate that there is no connection between the two standards, circuit integrity (FE/ PH) and System Circuit integrity (E). The test is carried out and certified from state recognised institutes. Standards - DIN 4102 part 12 (E30-E90) - NBN (Rf1, Rf1 1 / 2 ) Better than the standard! This test (E30-E90) is now the only worldwide standard for guaranteeing functional integrity of the complete electrical cable installation, including the fixing components, under normal operating conditions. 18 Datwyler

21 ROHS WEEE REACH Statement Datwyler As an environmentally conscious manufacturer and supplier of cabling solutions it is our concern not to use any environmentally harmful substances in our products. Based on current information, the hereinmentioned guidelines / regulations for banned substances are fully complied with. Exceptions are noted as such on the relevant data sheet. ROHS DIRECTIVE 2002/95/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 27 January 2003 on the restriction of the use of certain hazardous substances in electrical and electronic equipment and COMMISSION DECISION of 24 September 2010 amending, for the purposes of adapting to scientific and technical progress, the Annex to Directive 2002/95/EC of the European Parliament and Council as regards exemptions for applications containing lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls or polybrominated diphenyl ethers (2010/571/EU) WEEE REACH REGULATION (EC) No 1907/2006 OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 18 December 2006 concerning the Registration, Evaluation, Authorisation and Restriction of Chemicals (REACH), establishing a European Chemicals Agency, amending Direcctive 1999/45/EC and repealing Council Regulation (EEC) No 793/93 and Commission Regulation (EC) No 1488/94 as well as Council Directive 76/769/EEC Commission Directives 91/155/EEC, 93/67/EEC, 93/105/EC and 200/21/EC and COMMISSION REGULATION (EU) No 143/2011 of 17 February 2011 amending Annex XIV to Regulation (EC) No 1907/2006 of the European Parliament and of the council on the Registration, Evaluation, Authorisation and Restriction of Chemicals DIRECTIVE 2002/96/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 27 January 2003 on waste electrical and electronic equipment Datwyler 19

22 pyrofil Safety Cables Product overview Fire characteristics Design Rated voltage General properties Cable type Page Cat. Halogen-free Flame retardant Fire resistant Minimum smoke emission Circuit integrity System Circuit integrity E30 System Circuit integrity E60 System Circuit integrity E90 DIN VDE EN/CLC/IEC SEV BS max. 225 V max. 300 V 300/500 V 450/750 V 0.6/1 kv max. 70 C max. 90 C Concentric Ov. shield Armoured Halogen-free safety cables H07Z-U/R 22 E0 H05Z-/H07Z-K 24 E0 NHXMH 26 E0 (N)HXM(St)H 28 E0 N2XH 30 E0 N2XCH 34 E0 FE5 36 FE5 FE5-CL 40 FE5 J-H(St)H...Bd, grey 42 E0 J-H(St)H...Bd, red 44 E0 Halogen-free safety cables with circuit integrity Standard Fire Safety cable 46 FE180 UK Standard Fire Safety cable flex 48 FE180 UK Enhanced Fire Safety cable 50 FE180 UK Standard Fire Safety cable armoured 52 FE180 UK pyrofil Keram FE FE180 pyrofil Keram FE180 flex 58 FE180 pyrofil Keram FE180-CL 60 FE Datwyler

23 Fire characteristics Design Rated voltage General properties Cable type Page Cat. Halogen-free Flame retardant Fire resistant Minimum smoke emission Circuit integrity System Circuit integrity E30 System Circuit integrity E60 System Circuit integrity E90 DIN VDE EN/CLC/IEC SEV BS max. 225 V max. 300 V 300/500 V 450/750 V 0.6/1 kv max. 70 C max. 90 C Concentric Ov. shield Armoured Halogen-free safety cables with circuit integrity and System Circuit integrity (N)HXH FE180 E30-E60 pyrofil Keram 64 E30-E60 (N)HXCH FE180 E30-E60 pyrofil Keram (N)HXH FE180 E30-E60 CL pyrofil Keram (N)HXH FE180 E90 pyrofil Keram (N)HXCH FE180 E90 pyrofil Keram JE-H(St)H...Bd FE180 E30 L, orange pyrofil Keram JE-H(St)H Bd FE180 E30-E90, orange pyrofil Keram JE-H(St)H...Bd FE180 E30 L, red pyrofil Keram JE-H(St)H Bd FE180 E30-E90, red pyrofil Keram JE-H(St)HRH Bd FE180 E30-E90, red pyrofil Keram 68 E30-E60 70 E30-E60 74 E90 78 E90 80 E30 82 E30-E90 84 E30 86 E30-E90 88 E30-E90 ZGGFR Safety (Fibre optic safety cable) 90 (E30) wbggfr Safety (Fibre optic safety cable) 92 (E30) Datwyler 21

24 H07Z-U/R Single insulated core Halogen-free, with improved fire characteristics CENELEC EN (HD 22.9) Separator > 10 mm 2 Plastic tape Insulation FRNC/LS0H Conductor Solid/stranded Application Construction Technical Properties General Properties Wiring for switches, distributors, devices and lighting in buildings. Suitable for laying in conduits on or behind plasterwork and in closed installation ducts. Permitted operating temperature at conductor of 90 C, in accordance with HD 516. Conductor Bare copper, solid or stranded IEC 60228, EN 60228, (VDE 0295) Insulation Crosslinked polymer, EN , HD 22.9 Core colours Brown, black, grey, blue, green/yellow Rated voltage 450/750V 0.6/1kV for fixed installation Test voltage 2500V, 50Hz Operating temperature permanent installation -40 C to +90 C during installation +5 C to +50 C Zero halogen non corrosive gases IEC , EN , VDE Flame propagation IEC , EN , VDE Smoke density IEC /-2, EN /-2, VDE /-2 pyrofil H07Z-U/R 0511/e 22

25 H07Z-U/R Single insulated core Halogen-free, with improved fire characteristics CENELEC EN (HD 22.9) Article No. no. of cores x cross section cu content Total weight Outer diameter Fire load RE = circular, solid conductor RM = circular, stranded conductor Please specify required core colour when ordering. Additional dimensions available on request. n x mm 2 kg/km app. kg/km app. mm app. kwh/m 1 x 1,5 RE ,8 0,05 1 x 2,5 RE ,4 0,06 1 x 4 RE ,9 0,07 1 x 6 RE ,4 0,08 1 x 10 RE ,6 0,09 1 x 16 RM ,0 0,14 1 x 25 RM ,5 0,18 1 x 35 RM ,6 0,21 1 x 50 RM ,1 0,27 1 x 70 RM ,9 0,32 1 x 95 RM ,1 0,43 1 x 120 RM ,2 0,47 1 x 150 RM ,2 0,59 1 x 185 RM ,2 0,73 1 x 240 RM ,2 0,92 23

26 H05Z-K / H07Z-K Flexible single insulated core Halogen-free, with improved fire characteristics CENELEC EN (HD 22.9) Separator > 2,5 mm 2 Plastic tape Insulation FRNC/LS0H Conductor Flexible Application Construction Technical Properties General Properties Wiring for switches, distributors, devices and lighting in buildings. Suitable for laying in conduits on or behind plasterwork and in closed installation ducts. Permitted operating temperature at conductor of 90 C, in accordance with HD 516. Conductor Bare copper, flexible, IEC Class 5, EN Class 5, (VDE 0295 Class 5) Insulation Crosslinked polymer, EN , HD 22.9 Core colours Brown, black, grey, blue and green/yellow Rated voltage 300/500V for cross sections 1.0mm 2 450/750V for cross sections 1.5mm 2 0.6/1kV for fixed installation, for cross sections 1.5mm 2 Test voltage 2500V, 50Hz Operating temperature permanent installation -40 C to +90 C during installation +5 C to +50 C Zero halogen non corrosive gases IEC , EN , VDE Flame propagation IEC , EN , VDE Smoke density IEC /-2, EN /-2, VDE /-2 pyrofil H05Z-K / H07Z-K 0511/e 24

27 H05Z-K / H07Z-K Flexible single insulated core Halogen-free, with improved fire characteristics CENELEC EN (HD 22.9) Article No. no. of cores x cross section cu content Total weight Outer diameter Fire load Please specify required core colour when ordering. Additional dimensions available on request. n x mm 2 kg/km app. kg/km app. mm app. kwh/m 1 x 0, ,4 0,03 1 x 1, ,5 0,03 1 x 1, ,9 0,05 1 x 2, ,6 0,06 1 x ,4 0,07 1 x ,2 0,09 1 x ,7 0,11 1 x ,0 0,14 1 x ,9 0,20 1 x ,2 0,24 1 x ,2 0,32 1 x ,3 0,38 25

28 300/500V NHXMH Power cable Halogen-free, with improved fire characteristics VDE Insulation Cross-linked PE zero halogen Sheath FRNC/LS0H Filler Flame retardant, zero halogen Conductor Solid/stranded Application Construction Technical Properties For permanent installation in dry, damp or wet areas, on or behind plasterwork or in walls or concrete, except for direct embedding in cast, rammed or vibrated concrete. Also suitable for outdoor applications. Permitted operating temperature at conductor of +70 C. Conductor Bare copper, solid or stranded, IEC 60228, EN 60228, (VDE 0295) Insulation Cross-linked polyethylene, CENELEC HD 604 S1 and VDE XI1, Filler Halogen-free compound Outer sheath Polyolefin compound, VDE HM2 Core colours CENELEC HD 308 S2 and VDE 0293 Sheath colour Grey Imprint On request Nominal voltage 300/500V Test voltage 2000V, 50Hz General Properties Minimum bending radius permanent installation 4 x D (D = outer diameter) during installation 6 x D Operating temperature permanent installation -40 C to +70 C during installation +5 C to +50 C Zero halogen non corrosive gases IEC , EN , VDE Flame propagation IEC , EN , VDE Flame spread IEC Cat. C, EN Cat. C, VDE Cat. C Smoke density IEC /-2, EN /-2, VDE /-2 pyrofil NHXMH 0511/e 26

29 300/500V NHXMH Power cable Halogen-free, with improved fire characteristics VDE Article No. no. of cores x cross section cu content Total weight Outer diameter Fire load n x mm 2 kg/km app. kg/km app. mm app. kwh/m x 1,5 RE ,5 0, x 2,5 RE ,0 0, x 1,5 RE ,0 0, x 2,5 RE ,5 0, x 4 RE ,0 0, x 6 RE ,0 0, x 10 RE ,0 1, x 1,5 RE ,5 0, x 2,5 RE ,5 0, x 4 RE ,5 0, x 6 RE ,0 0, x 10 RE ,0 1, x 1,5 RE ,0 0, x 2,5 RE ,0 0, x 4 RE ,5 0, x 6 RE ,0 0, x 10 RE ,5 1, x 16 RM ,5 2, x 1,5 RE ,5 0, x 2,5 RE ,5 0, x 1,5 RE ,5 0, x 1,5 RE ,0 0, x 1,5 RE ,5 1,65 RE = circular, solid conductor RM = circular, stranded conductor Additional dimensions available on request. 27

30 (N)HXM(St)H Shielded power cable 300/500V Halogen free, with improved fire characteristics VDE Filler Flame retardant, zero halogen Insulation Cross-linked PE zero halogen Sheath FRNC/LS0H Shielding Al-laminated tape Drain wire Tinned copper Conductor Solid/stranded Application Construction Technical Properties For permanent installation in dry, damp or wet areas, on or behind plasterwork or in walls or concrete, except for direct embedding in cast, rammed or vibrated concrete. Also suitable for outdoor applications. Permitted operating temperature at conductor of +70 C. Conductor Bare copper, solid or stranded, IEC 60228, EN 60228, (VDE 0295) Insulation Cross-linked polyethylene, CENELEC HD 604 S1 and VDE XI1 Filler Halogen-free compound Shielding Al-laminated tape with tinned copper drain wire Outer sheath Polyolefin compound, VDE HM2 Core colours CENELEC HD 308 S2, (VDE 0293) Sheath colour Grey Imprint On request Nominal voltage 300/500V Test voltage 2000V, 50Hz General Properties Minimum bending radius permanent installation 4 x D (D = outer diameter) during installation 6 x D Operating temperature permanent installation -40 C to +70 C during installation +5 C to +50 C Zero halogen non corrosive gases IEC , EN , VDE Flame propagation IEC , EN , VDE Flame spread IEC Cat. C, EN Cat. C, VDE Cat. C Smoke density IEC /-2, EN /-2, VDE /-2 pyrofil (N)HXM(St)H 0511/e 28

31 (N)HXM(St)H Shielded power cable 300/500V Halogen free, with improved fire characteristics VDE Article No. no. of cores x cross section cu content Total weight Outer diameter Fire load n x mm 2 kg/km app. kg/km app. mm app. kwh/m 2 x 1,5 RE ,5 0,26 2 x 2,5 RE ,7 0, x 1,5 RE ,0 0, x 2,5 RE ,0 0, x 1,5 RE ,0 0, x 2,5 RE ,0 0, x 1,5 RE ,0 0, x 2,5 RE ,0 0,56 RE = circular, solid conductor RM = circular, stranded conductor Additional dimensions available on request. 29

32 N2XH Safety cable 0.6/1kV Halogen-free, with improved fire characteristics CENELEC HD 604 S1, VDE Insulation Cross-linked PE zero halogen Sheath FRNC/LS0H Filler Flame retardant, zero halogen Conductor Solid/stranded Application Construction Electrical Properties For permanent installation in dry, damp or wet areas, on or behind plasterwork or in walls or concrete. Also suitable for outdoor applications. The cable should only be laid directly in earth or water if a protective conduit is used. Permitted operating temperature at conductor of +90 C. Conductor Bare copper, solid or stranded, IEC 60228, EN 60228, (VDE 0295) Insulation Cross-linked polyethylene, CENELEC HD 604 S1 and VDE Filler Halogen-free compound or plastic tape Outer sheath Polyolefin compound, CENELEC HD 604 S1 and VDE HM4 Core colours CENELEC HD 308 S2 and VDE 0293 Sheath colour Black Imprint On request Nominal voltage Test voltage 0.6/1kV 4000V, 50Hz General Properties Minimum bending radius during and permanent installation 15* x D (single core cable) 12* x D (multicore cable) (D = outer diameter) permanent installation *50% reduction if installation at 30 C and with a template Operating temperature permanent installation -45 C to +90 C during installation -5 C to +50 C Zero halogen non corrosive gases IEC , EN , VDE Flame propagation IEC , EN , VDE Flame spread IEC /-24 Cat. A/C, EN /-24 Cat. A/C, VDE /-24 Cat. A/C Smoke density IEC /-2, EN /-2, VDE /-2 pyrofil N2XH 0511/e 30

33 N2XH Safety cable 0.6/1kV Halogen-free, with improved fire characteristics CENELEC HD 604 S1, VDE Article No. No. of cores x cross section Core colours Cu content Total weight Outer diameter Fire load n x mm 2 kg/km app. kg/km app. mm app. kwh/m x 4 RE black ,4 0, x 4 RE green/yellow ,4 0, x 6 RE black ,9 0, x 6 RE green/yellow ,9 0, x 10 RE black ,7 0, x 10 RE green/yellow ,7 0, x 16 RM black ,1 0, x 16 RM green/yellow ,1 0, x 25 RM black ,0 0, x 25 RM green/yellow ,0 0, x 35 RM black ,0 0, x 35 RM green/yellow ,0 0, x 50 RM black ,0 0, x 50 RM green/yellow ,0 0, x 70 RM black ,0 0, x 70 RM green/yellow ,0 0, x 95 RM black ,0 0, x 95 RM green/yellow ,0 0, x 120 RM black ,0 1, x 120 RM green/yellow ,0 1, x 150 RM black ,0 1, x 150 RM green/yellow ,0 1, x 185 RM black ,0 1, x 185 RM green/yellow ,0 1, x 240 RM black ,0 2, x 240 RM green/yellow ,0 2, x 300 RM black ,0 2, x 300 RM green/yellow ,0 2,34 RE = circular, solid conductor RM = circular, stranded conductor Additional dimensions available on request. 31

34 N2XH Safety cable 0.6/1kV Halogen-free, with improved fire characteristics CENELEC HD 604 S1, VDE Article No. no. of cores x cross section cu content Total weight Outer diameter Fire load n x mm 2 kg/km app. kg/km app. mm app. kwh/m x 1,5 RE ,0 0, x 1,5 RE ,0 0, x 2,5 RE ,0 0, x 4 RE ,0 0, x 6 RE ,5 0, x 10 RE ,0 0, x 16 RM ,0 1, x 1,5 RE ,0 0, x 2,5 RE ,0 0, x 4 RE ,0 0, x 6 RE ,0 0, x 10 RE ,0 1, x 16 RM ,0 1, x 25 RM ,0 2, x 35 RM ,0 2, x 50 RM ,0 3, x 70 RM ,0 4, x 95 RM ,0 5,16 RE = circular, solid conductor RM = circular, stranded conductor Additional dimensions available on request. 32

35 N2XH Safety cable 0.6/1kV Halogen-free, with improved fire characteristics CENELEC HD 604 S1, VDE Article No. no. of cores x cross section cu content Total weight Outer diameter Fire load n x mm 2 kg/km app. kg/km app. mm app. kwh/m x 1,5 RE ,0 0, x 2,5 RE ,0 0, x 4 RE ,0 0, x 6 RE ,0 0, x 10 RE ,0 1, x 16 RM ,0 1, x 25 RM ,5 3, x 1,5 RE ,0 0, x 2,5 RE ,0 0, x 1,5 RE ,0 1, x 2,5 RE ,0 1, x 1,5 RE ,0 1, x 2,5 RE ,0 1, x 1,5 RE ,0 1, x 1,5 RE ,0 1, x 1,5 RE ,0 2, x 1,5 RE ,0 2,41 RE = circular, solid conductor RM = circular, stranded conductor Additional dimensions available on request. 33

36 N2XCH Safety cable 0.6/1kV Halogen-free, with improved fire characteristics CENELEC HD 604 S1, VDE Separator Plastic tape Reinforcing helix Bare copper tape Insulation Cross-linked PE zero halogen Sheath FRNC/LS0H Concentric conductor Bare copper wire Filler Flame retardant, zero halogen Conductor Solid/ stranded Application Construction Electrical Properties For permanent installation in dry, damp or wet areas, on or behind plasterwork or in walls or concrete. Also suitable for outdoor applications. The cable should only be laid directly in earth or water if a protective conduit is used. Permitted operating temperature at conductor of +90 C. Conductor Bare copper, solid or stranded, IEC 60228, EN 60228, (VDE 0295) Insulation Cross-linked polyethylene, CENELEC HD 604 S1 and VDE Filler Halogen-free compound or plastic tape Concentric conductor Bare copper wires with reinforced helix Separator Plastic tape Outer sheath Polyolefin compound, CENELEC HD 604 S1 and VDE HM4 Core colours CENELEC HD 308 S2 and VDE 0293 Sheath colour Black Imprint On request Nominal voltage Test voltage 0.6/1kV 4000V, 50Hz General Properties Minimum bending radius during and permanent installation 12 x D (multicore cable) (D = outer diameter) Operating temperature permanent installation -45 C to +90 C during installation -5 C to +50 C Zero halogen non corrosive gases IEC , EN , VDE Flame propagation IEC , EN , VDE Flame spread IEC /-24 Cat. A/C, EN /-24 Cat. A/C, VDE /-24 Cat. A/C Smoke density IEC /-2, EN /-2, VDE /-2 pyrofil N2XCH 0511/e 34

37 N2XCH Safety cable 0.6/1kV Halogen-free, with improved fire characteristics CENELEC HD 604 S1, VDE Article No. no. of cores x cross section cu content Total weight Outer diameter Fire load n x mm 2 kg/km app. kg/km app. mm app. kwh/m x 1,5 RE/1, ,0 0, x 2,5 RE/2, ,0 0, x 1,5 RE/1, ,0 0, x 2,5 RE/2, ,0 0, x 4 RE/ ,0 0, x 6 RE/ ,0 0, x 10 RE/ ,0 0, x 16 RM/ ,0 1, x 25 RM/ ,0 1, x 35 RM/ ,0 2, x 50 RM/ ,0 2, x 1,5 RE/1, ,0 0, x 2,5 RE/2, ,0 0, x 4 RE/ ,0 0, x 6 RE/ ,0 0, x 10 RE/ ,0 1, x 16 RM/ ,0 1, x 25 RM/ ,0 2, x 35 RM/ ,0 2, x 50 RM/ ,0 3, x 70 RM/ ,0 4, x 95 RM/ ,0 5, x 120 RM/ ,0 6, x 150 RM/ ,0 7, x 185 RM/ ,0 9, x 240 RM/ ,0 12, x 1,5 RE/2, ,0 0, x 2,5 RE/2, ,0 0, x 4 RE/ ,0 1, x 6 RE/ ,0 1, x 1,5 RE/2, ,0 1, x 2,5 RE/ ,0 1, x 1,5 RE/ ,0 2, x 1,5 RE/ ,0 2, x 2,5 RE/ ,0 3,01 RE = circular, solid conductor, RM = circular, stranded conductor Additional dimensions available on request. 35

38 Developed especially for the Swiss market Preventive fire protection FE5 Safety cable 0.6/1kV Halogen-free, with improved fire characteristics With reference to SEV TP 20B/3C and CENELEC HD 604 S1 part 5. H Insulation Polyolefin flame retardant, low smoke, zero halogen Sheath FRNC/LS0H Conductor Solid/stranded Application Construction Electrical Properties For permanent installation in dry, damp or wet areas, on or behind plasterwork or in walls or concrete. The cable should only be laid directly in earth or water if a protective conduit is used. Permitted operating temperature at conductor of +90 C. Conductor Bare copper, solid or stranded, IEC 60228, EN Insulation Polyolefin compound, CENELEC HD 604 S1 part 5 sec. H Outer sheath Flame retardant Polyolefin compound CENELEC HD 604 S1 part 5 sec. H Core colours CENELEC HD 308 S2 Sheath colour Orange/Black Imprint On request Nominal voltage Test voltage 0.6/1kV 3500V, 50Hz General Properties Minimum bending radius during and permanent installation 15* x D (single core cable) 12* x D (multicore cable) (D = outer diameter) permanent installation *50% reduction if installation at 30 C and with a template Operating temperature permanent installation -45 C to +90 C during installation -5 C to +50 C Zero halogen non corrosive gases IEC , EN , VDE SEV TP 20B/3C Flame propagation IEC , EN , VDE SEV TP 20B/3C Flame spread IEC Cat. C, EN Cat. C, VDE Cat. C SEV TP 20B/3C Smoke density IEC /-2, EN /-2, VDE /-2 SEV TP 20B/3C pyrofil FE5 0511/e 36

39 FE5 Safety cable 0.6/1kV Halogen-free, with improved fire characteristics With reference to SEV TP 20B/3C and CENELEC HD 604 S1 part 5. H Article No. no. of cores x cross section Core colour Cu content Total weight Outer diameter Fire load n x mm 2 kg/km app. kg/km app. mm kwh/m x 16 RM black ,1 0, x 16 RM green/yellow ,1 0, x 25 RM black , x 25 RM green/yellow , x 35 RM black , x 35 RM green/yellow , x 50 RM black , x 50 RM green/yellow , x 70 RM black , x 70 RM green/yellow , x 95 RM black , x 95 RM green/yellow , x 120 RM black , x 120 RM green/yellow , x 150 RM black ,43 1 x 150 RM green/yellow , x 185 RM black , x 185 RM green/yellow , x 240 RM black , x 240 RM green/yellow , x 300 RM black , x 300 RM green/yellow ,34 RE = circular, solid conductor RM = circular, stranded conductor Additional dimensions available on request. 37

40 Developed especially for the Swiss market Preventive fire protection FE5 Safety cable 0.6/1kV Halogen-free, with improved fire characteristics With reference to SEV TP 20B/3C and CENELEC HD 604 S1 part 5. H Article No. no. of cores x cross section cu content Total weight Outer diameter Fire load n x mm 2 kg/km app. kg/km app. mm kwh/m 2 x 1.5 RE ,17 2 x 2.5 RE ,24 3 x 1.5 RE ,18 3 x 2.5 RE ,24 3 x 4 RE ,31 3 x 6 RE ,45 3 x 10 RE , x 16 RM ,22 4 x 1.5 RE ,23 4 x 2.5 RE ,29 4 x 4 RE ,39 4 x 6 RE ,51 4 x 10 RE , x 16 RM , x 25 RM , x 35 RM , x 50 RM , x 70 RM , x 95 RM ,16 RE = circular, solid conductor RM = circular, stranded conductor Additional dimensions available on request. 38

41 FE5 Safety cable 0.6/1kV Halogen-free, with improved fire characteristics With reference to SEV TP 20B/3C and CENELEC HD 604 S1 part 5. H Article No. no. of cores x cross section cu content Total weight Outer diameter Fire load n x mm 2 kg/km app. kg/km app. mm kwh/m 5 x 1.5 RE ,0 0, x 2.5 RE ,0 0, x 4 RE ,0 0, x 6 RE ,0 0, x 10 RE ,0 0, x 16 RM ,0 1, x 25 RM ,5 3, x 1.5 RE ,0 0, x 2.5 RE ,0 0, x 4 RE ,0 0, x 6 RE ,0 0, x 10 RE ,0 1,03 8 x 1.5 RE ,0 0,38 8 x 2.5 RE ,0 0, x 1.5 RE ,0 0,50 10 x 2.5 RE ,0 0, x 1.5 RE ,0 0,64 12 x 2.5 RE ,0 0,83 RE = circular, solid conductor RM = circular, stranded conductor Additional dimensions available on request. 39

42 Developed especially for the Swiss market Preventive fire protection FE5-CL Safety cable 0.6/1kV, armoured with rodent protection Halogen-free, with improved fire characteristics With reference to SEV TP 20B/3C and CENELEC HD 604 S1 part 5. H Armouring Galvanised steel tape Insulation Cross-linked PE zero halogen Sheath FRNC/LS0H Inner sheath Polyolefin flame retardant, zero halogen Conductor Solid/stranded Application Construction For permanent installation in dry, damp or wet areas, on or behind plasterwork or in walls or concrete. Also suitable for outdoor applications. The cable should only be laid directly in earth or water if a protective conduit is used. Permitted operating temperature at conductor of +90 C. Conductor Bare copper, solid or stranded, IEC 60228, EN Insulation Crosslinked polyethylene CENELEC HD 604 S1 part 5 sec. H Inner sheath Flame retardant Polyolefin compound CENELEC HD 604 S1 part 5 sec. H Armouring/ rodent protection Single core cable with copper tape [CLCU) and Multicore cable with galvanised steel tape [CL] Outer sheath Flame retardant Polyolefin compound CENELEC HD 604 S1 part 5 sec. H Core colours CENELEC HD 308 S2 Sheath colour Black Imprint On request Electrical Properties General Properties Nominal voltage Test voltage 0.6/1kV 3500V, 50Hz Minimum bending radius during and permanent installation 15* x D (single core cable) 12* x D (multicore cable) (D = outer diameter) Operating temperature permanent installation -45 C to +90 C during installation -5 C to +50 C Zero halogen non corrosive gases IEC , EN , VDE SEV TP 20B/3C Flame propagation IEC , EN , VDE SEV TP 20B/3C Flame spread IEC Cat. C, EN Cat. C, VDE Cat. C SEV TP 20B/3C Smoke density IEC /-2, EN /-2, VDE /-2 SEV TP 20B/3C pyrofil FE5-CL 0511/e 40

43 FE5-CL Safety cable 0.6/1kV, armoured with rodent protection Halogen-free, with improved fire characteristics With reference to SEV TP 20B/3C and CENELEC HD 604 S1 part 5. H Article No. no. of cores x cross section cu content Total weight Outer diameter Fire load n x mm 2 kg/km app. kg/km app. mm kwh/m 2 x 1,5 RE ,30 2 x 2,5 RE ,40 3 x 1,5 RE , x 2,5 RE , x 4 RE , x 6 RE , x 10 RE ,96 3 x 16 RM , x 1,5 RE ,38 4 x 2,5 RE ,50 4 x 4 RE ,62 4 x 6 RE ,80 4 x 10 RE ,08 4 x 16 RM ,92 4 x 25 RM ,53 4 x 35 RM , x 2,5 RE ,61 5 x 4 RE , x 6 RE , x 10 RE ,31 5 x 10 RM , x 16 RM , x 25 RM , x 35 RM , x 50 RM ,90 5 x 70 RM , x 95 RM ,64 7 x 1,5 RE , x 2,5 RE ,71 7 x 4 RE , x 6 RE , x 10 RE ,58 8 x 1,5 RE ,62 8 x 2,5 RE ,82 10 x 1,5 RE ,77 10 x 2,5 RE ,01 12 x 1,5 RE , x 2,5 RE ,26 21 x 2,5 RE ,00 27 x 2,5 RE ,16 RE = circular, solid conductor, RM = circular, stranded conductor Additional dimensions available on request. 41

44 J-H(St)H...Bd Wiring cable for telecomunication systems max. 300V Halogen-free, with improved fire characteristics VDE 0815 Separator Plastic tape Insulation Halogen-free polymer compound Sheath FRNC/LS0H Shielding Al-laminated plastic-foil Drain wire Tinned copper Conductor Solid Application Construction Electrical Properties General Properties Installation cable with electrostatic shield in fire vulnerable areas with high concentration of people and property value. For telecommunication and IT systems for lossless data and signal transmission. Suitable for fixed laying in dry and humid rooms, on-wall and in-wall, outdoor use, no laying underground. Not to be used for power transmission. Permitted operating temperature at conductor of +70 C. Conductor Bare copper, solid, 0.6 or 0.8mm diameter Insulation Halogen-free polymer compound, EN Core idendification DIN VDE 0815 (different colours) Stranding Cores twisted to star-quads and quads to units Shielding Al-laminated plastic-foil with drain wire, copper tinned Outer Sheath Halogen-free polymer compound, EN Sheath colour Grey Rated voltage Test voltage Conductor resistance Loop: Insulation resistance Capacity max. 300 V 800V 50Hz 0,6 mm max. 130 Ω/km 0,8 mm max. 73,2 Ω/km min. 100 MΩ x km max. 120 nf/km Minimum bending radius permanent installation 2,5 x D during installation 7,5 x D (D = outer diameter) Operation temperatur permanent installation -30 C bis +70 C Operation temperatur during installation - 5 C bis +50 C Zero halogen non corrosive gases IEC , EN , VDE Flame propagation IEC , EN , VDE Flame spread IEC Cat. C, EN Cat. C, VDE Cat. C Smoke density IEC /-2, EN /-2, VDE /-2 pyrofil J-H(St)H...Bd 0511/e 42

45 J-H(St)H...Bd Wiring cable for telecomunication systems max. 300V Halogen-free, with improved fire characteristics VDE 0815 Article No. no. of cores x conductor diameter cu content Total weight Outer diameter Fire load n x mm kg/km app. kg/km app. mm app. kwh/m 1 x 2 x 0, ,0 0, x 2 x 0, ,0 0, x 2 x 0, ,0 0, x 2 x 0, ,0 0, x 2 x 0, ,0 0, x 2 x 0, ,0 0, x 2 x 0, ,0 0, x 2 x 0, ,0 1, x 2 x 0, ,0 1, x 2 x 0, ,0 1, x 2 x 0, ,0 2, x 2 x 0, ,0 2, x 2 x 0, ,0 0, x 2 x 0, ,0 0, x 2 x 0, ,0 0, x 2 x 0, ,0 0, x 2 x 0, ,0 0, x 2 x 0, ,0 1, x 2 x 0, ,0 1, x 2 x 0, ,0 1, x 2 x 0, ,0 2, x 2 x 0, ,0 2, x 2 x 0, ,0 3, x 2 x 0, ,0 4,07 Additional dimensions available on request. 43

46 J-H(St)H...Bd Fire alarm cable max. 300V Halogen-free, with improved fire characteristics VDE 0815 Separator Plastic tape Insulation Halogen-free polymer compound BRANDMELDEKABEL Sheath FRNC/LS0H Shielding Al-laminated plastic-foil Drain wire Tinned copper Conductor Solid Application Construction Electrical Properties General Properties Installation cable with electrostatic shield in fire vulnerable areas with high concentration of people and property value. For telecommunication and IT-systems for lossless data and signal transmission. Suitable for fixed laying in dry and humid rooms, on-wall and in-wall, outdoor use, no laying underground. Not to be used for power transmission. Permitted operating temperature at conductor of +70 C. Conductor Bare copper, solid, 0.6 or 0.8mm diameter Insulation Halogen-free polymer compound, EN Core idendification DIN VDE 0815 (different colours) Stranding Cores twisted to star-quads and quads to units Shielding Al-laminated plastic-foil with drain wire, copper tinned Outer Sheath Halogen-free polymer compound, EN Sheath colour Red Rated voltage Test voltage Conductor resistance Loop: Insulation resistance Capacity max. 300 V 800V 50Hz 0,6 mm max. 130 Ω/km 0,8 mm max. 73,2 Ω/km min. 100 MΩ x km max. 120 nf/km Minimum bending radius permanent installation 2,5 x D during installation 7,5 x D (D = outer diameter) Operation temperatur permanent installation -30 C bis +70 C Operation temperatur during installation - 5 C bis +50 C Zero halogen non corrosive gases IEC , EN , VDE Flame propagation IEC , EN , VDE Flame spread IEC Cat. C, EN Cat. C, VDE Cat. C Smoke density IEC /-2, EN /-2, VDE /-2 pyrofil J-H(St)H...Bd BMK 0511/e 44

47 J-H(St)H...Bd Fire alarm cable max. 300V Halogen-free, with improved fire characteristics VDE 0815 Article No. no. of cores x conductor diameter cu content Total weight Outer diameter Fire load n x mm kg/km app. kg/km app. mm app. kwh/m x 2 x 0, ,0 0, x 2 x 0, ,0 0, x 2 x 0, ,0 0, x 2 x 0, ,0 0, x 2 x 0, ,0 0, x 2 x 0, ,0 1, x 2 x 0, ,0 1, x 2 x 0, ,0 1, x 2 x 0, ,0 2, x 2 x 0, ,0 2, x 2 x 0, ,0 3, x 2 x 0, ,0 4,07 Fire alarm cable with red sheath and imprint Brandmeldekabel (fire alarm cable). Additional dimensions available on request. 45

48 Standard Fire Safety Cable Fire alarm cable 300/500V Halogen-free, with improved fire characteristics BS and BS Standard Inner covering Glass fiber tape Insulation Fire resistant special compound Sheath FRNC/LS0H Shielding Al-laminated tape Drain wire Tinned copper Conductor Solid Application Construction Electrical Properties Cable for fire alarm systems and emergency lighting for permament installation in buildings. Permitted operating temperature at conductor +90 C. Conductor Bare copper, stranded, IEC and EN Insulation Special compound, BS EN Core colours 2 cores + earth: blue, brown 3 cores + earth: brown, black, grey 4 cores + earth: blue, brown, black, grey Inner covering Glass fibre tape Shielding Al-laminated tape and tinned copper drain wire IEC 60228, EN Separator Plastic tape Sheath Polyolefin compound, BS 7655, LTS3 Sheath colour Red, white (other colours on request) Imprint On request Nominal voltage 300/500V Test voltage 2000V, 50Hz pyrofil Standard Fire Safety Cable 0511/e General Properties Minimum bending radius during and permanent installation 6 x D (D = outer diameter) Operating Temperature permanent installation -15 C to +90 C during installation -5 C to +50 C Zero halogen, IEC and IEC , EN , EN , non corrosive gases VDE part 2-1 and part 2-2 Flame propagation IEC , EN , VDE Flame spread IEC /-24 Cat. A/C, EN /-24 Cat. A/C, VDE /-24 Cat. A/C Smoke density IEC /-2, EN /-2, VDE /-2 Circuit integrity [FE/PH] IEC /-21 (180 minutes), VDE 0472 part 814 (FE180), BS 6387 (cat. CWZ), BS EN Annex E (30 minutes), BS EN (PH120), IEC (120 minutes), VDE

49 Standard Fire Safety Cable Fire alarm cable 300/500V Halogen-free, with improved fire characteristics BS and BS Standard Article No. colour no. of cores x cross section cu content Total weight Outer diameter Fire load n x mm 2 kg/km app. kg/km app. mm kwh/m red 2 x 1, ,7 0, white 2 x 1, ,7 0, red 2 x 1, ,3 0, white 2 x 1, ,3 0, red 2 x 2, ,7 0, white 2 x 2, ,7 0, red 3 x 1, ,1 0, white 3 x 1, ,1 0, red 3 x 1, ,7 0, white 3 x 1, ,7 0, red 3 x 2, ,3 0, white 3 x 2, ,3 0, red 4 x 1, ,0 0, white 4 x 1, ,0 0, red 4 x 1, ,7 0, white 4 x 1, ,7 0, red 4 x 2, ,4 0, white 4 x 2, ,4 0, red 7 x 1, ,6 0,42 Additional dimensions available on request. 47

50 Standard Fire Safety Cable Fire alarm cable 300/500V, flex Halogen-free, with improved fire characteristics BS and BS Standard Inner covering Glass fibre tape Insulation Fire resistant special compound Sheath FRNC/LS0H Shielding Al-laminated tape Drain wire Tinned copper Conductor Stranded Application Construction Electrical Properties Cable for fire alarm systems and emergency lighting for permament installation in buildings. Permitted operating temperature at conductor +90 C. Conductor Bare copper, stranded, IEC and EN Insulation Special compound, BS EN Core colours 2 cores + earth: blue, brown 3 cores + earth: brown, black, grey 4 cores + earth: blue, brown, black, grey Inner covering Glass fibre tape Shielding Al-laminated tape and tinned copper drain wire IEC 60228, EN Separator Plastic tape Sheath Polyolefin compound, BS 7655, LTS3 Sheath colour Red (white or black on request) Imprint On request Nominal voltage 300/500V Test voltage 2000V, 50Hz pyrofil Standard Fire Safety Cable flex 0511/e General Properties Minimum bending radius during and permanent installation 6 x D (D = outer diameter) Operating temperature permanent installation -15 C to +90 C during installation -5 C to +50 C Zero halogen, IEC and IEC , EN , EN , non corrosive gases VDE part 2-1 and part 2-2 Flame propagation IEC , EN , VDE Flame spread IEC /-24 Cat. A/C, EN /-24 Cat. A/C, VDE /-24 Cat. A/C Smoke density IEC /-2, EN /-2, VDE /-2 Circuit integrity [FE/PH] IEC /-21 (180 minutes), VDE 0472 part 814 (FE180), BS 6387 (cat. CWZ), BS EN Annex E (30 minutes), BS EN (PH120), IEC (120 minutes), VDE

51 Standard Fire Safety Cable Fire alarm cable 300/500V, flex Halogen-free, with improved fire characteristics BS and BS Standard Article No. colour no. of cores x cross section cu content Total weight Outer diameter Fire load n x mm 2 kg/km app. kg/km app. mm kwh/m red 2 x 1, ,0 0, red 2 x 1, ,9 0, red 2 x 2, ,4 0,30 red 3 x 1, ,5 0, red 3 x 1, ,4 0,27 red 3 x 2, ,0 0,35 red 4 x 1, ,4 0,25 red 4 x 1, ,4 0, red 4 x 2, ,2 0,44 Additional dimensions available on request. 49

52 Enhanced Fire Safety Cable Fire alarm cable 300/500V Halogen-free, with improved fire characteristics BS and BS Inner covering Glass fibre tape Insulation Fire resistant special compound Sheath FRNC/LS0H Shielding Alu-laminated tape Drain wire Tinned copper Conductor Solid Application Construction Electrical Properties General Properties Cable for fire alarm systems and emergency lighting for permament installation in buildings. Permitted operating temperature at conductor +90 C. Conductor Bare copper, solid, IEC and EN Insulation Special compound, BS EN Core colours 2 cores + earth: blue, brown Inner covering Glass fibre tape Shielding Al-laminated tape and tinned copper drain wire IEC 60228, EN Separator Plastic tape Sheath Polyolefin compound, BS 7655, LTS3 Sheath colour Red (white or black on request) Imprint On request Nominal voltage 300/500V Test voltage 2000V, 50Hz Minimum bending radius during and permanent installation 6 x D (D = outer diameter) Operating temperature permanent installation -15 C to +90 C during installation -5 C to +50 C Zero halogen, IEC and IEC , EN , EN , non corrosive gases VDE part 2-1 and part 2-2 Flame propagation IEC , EN , VDE Flame spread IEC /-24 Cat. A/C, EN /-24 Cat. A/C, VDE /-24 Cat. A/C Smoke density IEC /-2, EN /-2, VDE /-2 Circuit integrity [FE/PH] IIEC /-21 (180 minutes), VDE 0472 part 814 (FE180) BS 6387 (cat. CWZ) and BS (120 minutes), BS EN (PH120), IEC (120 minutes), VDE pyrofil Enhanced Fire Safety Cable 0511/e 50

53 Enhanced Fire Safety Cable Fire alarm cable 300/500V Halogen-free, with improved fire characteristics BS and BS Article No. colour no. of cores x cross section cu content Total weight Outer diameter Fire load n x mm 2 kg/km app. kg/km app. mm kwh/m red 2 x 1, ,3 0, white 2 x 1, ,3 0, red 2 x 2, ,7 0, white 2 x 2, ,7 0,26 Stranded versions and additional dimensions available on request. 51

54 Armoured Standard Fire Safety Cable Fire alarm cable with steel wire braiding 300/500V Halogen-free, with improved fire characteristics with reference to BS Inner sheath Polyolefin compound Inner covering Glass fibre tape Insulation Fire resistant special compound Sheath FRNC/LS0H Armouring galvanised steel wire braid Shielding Alu-laminated tape Drain wire Tinned copper Conductor Solid Application Construction Electrical Properties Armoured cable for fire alarm systems and emergency lighting for permament installation in buildings. Permitted operating temperature at conductor of +90 C. Conductor Bare copper, solid or stranded in accordance with IEC and EN Insulation Special compound, BS EN Core colours 2 cores + earth: brown, blue 3 cores + earth: brown, black, grey 4 cores + earth: brown, black, grey, blue Inner covering Glass fibre tape Shielding Al-laminated tape and tinned copper drain wire IEC class 1or 2, EN Inner sheath Polyolefin compound Armouring GSWB, galvanised steel wire braid Outer Sheath Polyolefin compound, BS 7655 LTS3 Sheath colour Red (white or black on request) Imprint On request Nominal voltage 300/500V Test voltage 2000V, 50Hz General Properties Minimum bending radius during and permanent installation 6 x D (D = outer diameter) Operating temperature permanent installation -15 C to +90 C during installation -5 C to +50 C pyrofil Standard Fire Safety Cable 0511/e Zero halogen, IEC and IEC , EN , EN , non corrosive gases VDE part 2-1 and part 2-2 Flame propagation IEC , EN , VDE Flame spread IEC /-24 Cat. A/C, EN /-24 Cat. A/C, VDE /-24 Cat. A/C Smoke density IEC /-2, EN /-2, VDE /-2 Circuit integrity [FE/PH] IEC /-21 (180 minutes), VDE 0472 part 814 (FE180), BS 6387 (cat. CWZ), BS EN (PH120), IEC (120 minutes), VDE

55 Armoured Standard Fire Safety Cable Fire alarm cable with steel wire braiding 300/500V Halogen-free, with improved fire characteristics with reference to BS Article No. colour no. of cores x cross section cu content Total weight Outer diameter Fire load n x mm 2 kg/km app. kg/km app. mm kwh/m red 2 x 1, ,0 0,40 red 2 x 2, ,0 0,50 Stranded versions and additional dimensions available on request. 53

56 Developed especially for the Swiss market Preventive fire protection FE180 Safety cable 0.6/1kV, pyrofil Keram Halogen-free, with improved fire characteristics with reference to SEV TP 20B/3C and CENELEC HD 604 S1 part 5.H Circuit integrity (FE180) in accordance with IEC Filler Flame retardant, zero halogen Fire barrier High-peformance Keram compound Sheath FRNC/LS0H Insulation Crosslinked polymer zero halogen Conductor Solid/stranded Application Construction Electrical Properties are used in all situations that require special protection against fire and flame damage for people and equipment and where a high degree of safety conditions must be fulfilled. Suitable for indoor applications. For outdoor applications, protection must be provided against exposure to direct sunlight. The cable should only be laid directly in earth or water if a protective conduit is used. Permitted operating temperature at conductor +90 C. Conductor Bare copper, solid or stranded in accordance with IEC and EN Insulation Special compound, HD 604 S1 part 5 H Filler HD 604 S1 part 5 H Outer sheath Compound, HD 604 S1 part 5 H Core colours CENELEC HD 308 S2 Sheath colour Orange Imprint On request Nominal voltage Test voltage 0.6/1kV 3500V, 50Hz General Properties Minimum bending radius during and permanent installation 15* x D (single core cable) 12* x D (multicore cable) (D = outer diameter) permanent installation Operating temperature permanent installation -45 C to +90 C during installation -5 C to +50 C *50% reduction if installation at 30 C and with a template pyrofil Keram FE /e Zero halogen, IEC , EN , VDE , non corrosive gases SEV TP20B/3C Flame propagation IEC , EN , VDE , SEV TP20B/3C Flame spread IEC /-24 Cat. B/C, EN /-24 Cat. B/C, VDE /24 Cat. B/C, SEV TP20B/3C Smoke density IEC /-2, EN /-2, VDE /-2, SEV TP20B/3C Circuit integrity [FE/PH] IEC /-21 (180 minutes), VDE 0472 part 814 (FE180), SEV TP20B/3C

57 FE180 Safety cable 0.6/1kV, pyrofil Keram Halogen-free, with improved fire characteristics with reference to SEV TP 20B/3C and CENELEC HD 604 S1 part 5.H Circuit integrity (FE180) in accordance with IEC Article No. no. of cores x cross section cu content Total weight Outer diameter Fire load n x mm 2 kg/km app. kg/km app. mm kwh/m x 16 RM ,8 0, x 25 RM ,3 0, x 35 RM ,4 0, x 50 RM ,9 0, x 70 RM ,7 0, x 95 RM ,1 0, x 120 RM ,2 0, x 150 RM ,4 1, x 185 RM ,6 1, x 240 RM ,8 1, x 1,5 RE ,8 0, x 2,5 RE ,0 0,28 2 x 4 RE ,4 0,37 2 x 6 RE ,8 0,46 2 x 10 RE ,0 0, x 16 RM ,2 1, x 25 RM ,2 1,42 2 x 35 RM ,4 1,66 2 x 50 RM ,4 2,06 2 x 70 RM ,4 2,61 2 x 95 RM ,0 3,46 2 x 120 RM ,4 3,87 2 x 150 RM ,6 4,75 2 x 185 RM ,2 5,86 2 x 240 RM ,6 7, x 1,5 RE ,3 0, x 2,5 RE ,5 0, x 4 RE ,0 0, x 6 RE ,5 0,51 3 x 10 RE ,8 0, x 16 RM ,3 1, x 25 RM ,6 1, x 35 RM ,9 1, x 50 RM ,2 2, x 70 RM ,7 2,88 RE = circular, solid conductor RM = circular, stranded conductor Additional dimensions available on request. 55

58 Developed especially for the Swiss market Preventive fire protection FE180 Safety cable 0.6/1kV, pyrofil Keram Halogen-free, with improved fire characteristics with reference to SEV TP 20B/3C and CENELEC HD 604 S1 part 5.H Circuit integrity (FE180) in accordance with IEC Article No. no. of cores x cross section cu content Total weight Outer diameter Fire load n x mm 2 kg/km app. kg/km app. mm kwh/m x 1,5 RE ,1 0, x 2,5 RE ,5 0, x 4 RE ,2 0, x 6 RE ,8 0,61 4 x 10 RE ,4 0, x 16 RM ,1 1, x 25 RM ,8 1, x 35 RM ,4 2, x 50 RM ,5 2, x 70 RM ,2 3, x 95 RM ,7 4, x 120 RM ,6 5, x 150 RM ,0 6, x 185 RM ,3 7, x 240 RM ,0 10, x 1,5 RE ,9 0, x 2,5 RE ,6 0, x 4 RE ,4 0, x 6 RE ,2 0,76 5 x 10 RE ,1 1, x 16 RM ,1 1, x 25 RM ,2 2, x 35 RM ,5 2, x 50 RM ,8 3, x 70 RM ,0 4, x 95 RM ,6 5,89 5 x 120 RM ,7 6,49 5 x 150 RM ,5 8,08 5 x 185 RM ,3 9,84 5 x 240 RM ,8 12,44 RE = circular, solid conductor RM = circular, stranded conductor Additional dimensions available on request. 56

59 FE180 Safety cable 0.6/1kV, pyrofil Keram Halogen-free, with improved fire characteristics with reference to SEV TP 20B/3C and CENELEC HD 604 S1 part 5.H Circuit integrity (FE180) in accordance with IEC Article No. no. of cores x cross section cu content Total weight Outer diameter Fire load n x mm 2 kg/km app. kg/km app. mm kwh/m x 1,5 RE ,8 0, x 2,5 RE ,5 0,53 7 x 4 RE ,5 0, x 6 RE ,7 0,89 7 x 10 RE ,3 1, x 1,5 RE ,9 0,48 8 x 2,5 RE ,8 0, x 1,5 RE ,8 0,69 10 x 2,5 RE ,0 0, x 1,5 RE ,2 0, x 2,5 RE ,7 0, x 1,5 RE ,7 0,99 21 x 2,5 RE ,0 1, x 1,5 RE ,4 1,3 27 x 2,5 RE ,9 1,7 RE = circular, solid conductor RM = circular, stranded conductor Additional dimensions available on request. 57

60 Developed especially for the Swiss market Preventive fire protection FE180 flex Control cable flex 300/500V, pyrofil Keram Halogen-free, with improved fire characteristics with reference to SEV TP 20B/3C and CENELEC HD 604 S1 part 5.H Circuit integrity (FE180) in accordance with IEC Filler Flame retardant, zero halogen Fire barrier High performance Keram special compound Sheath FRNC/LS0H Insulation Crosslinked polymer zero halogen Conductor flexible Application Construction Electrical Properties are used in all situations that require special protection against fire and flame damage for people and equipment and where a high degree of safety conditions must be fulfilled. Suitable for indoor applications. For outdoor applications, protection must be provided against exposure to direct sunlight. The cable should only be laid directly in earth or water if a protective conduit is used. Permitted operating temperature at conductor +90 C. Conductor Bare copper, flexible, IEC class 5, EN Insulation Special compound, HD 604 S1 part 5 H Filler HD 604 S1 part 5 H Outer sheath Compound, HD 604 S1 part 5 H Core colours CENELEC HD 308 S2 Sheath colour Orange Imprint On request Nominal voltage 300/500V Test voltage 2000V, 50Hz General Properties Minimum bending radius permanent installation 4 x D (D = outer diameter) during installation 6 x D Operating temperature permanent installation -45 C to +90 C during installation -5 C to +50 C Zero halogen, IEC , EN , VDE , non corrosive gases SEV TP20B/3C Flame propagation IEC , EN , VDE , SEV TP20B/3C Flame spread IEC Cat. C, EN Cat.C, VDE Cat. C, SEV TP20B/3C Smoke density IEC /-2, EN /-2, VDE /-2, SEV TP20B/3C Circuit integrity [FE/PH] IEC /-21 (180 minutes), VDE 0472 part 814 (FE180), SEV TP20B/3C pyrofil Keram FE180 flex 0511/e 58

61 FE180 flex Control cable flex 300/500V, pyrofil Keram Halogen-free, with improved fire characteristics with reference to SEV TP 20B/3C and CENELEC HD 604 S1 part 5.H Circuit integrity (FE180) in accordance with IEC Article No. no. of cores x cross section cu content Total weight Outer diameter Fire load n x mm 2 kg/km app. kg/km app. mm kwh/m x 1, ,27 4 x 4, , x 1, , x 2, ,55 5 x 4, ,65 5 x 6, , x 1, , x 1, , x 1, , x 1, , x 1, ,10 Additional dimensions available on request. 59

62 Developed especially for the Swiss market Preventive fire protection FE180-CL Safety cable 0.6/1kV armoured with rodent protection, pyrofil Keram Halogen-free, with improved fire characteristics with reference to SEV TP 20B/3C and CENELEC HD 604 S1 part 5.H Circuit integrity (FE180) in accordance with IEC Inner sheath Polyolefin flame retardant, low smoke, zero halogen Filler Flame retardant, zero halogen Fire barrier High-peformance Keram compound Sheath FRNC/LS0H Armouring Galvanised steel tape Insulation Crosslinked polymer zero halogen Conductor Solid/stranded Application Construction Electrical Properties are used in all situations that require special protection against fire and flame damage for people and equipment and where a high degree of safety conditions must be fulfilled. Suitable for indoor applications. For outdoor applications, protection must be provided against exposure to direct sunlight. The cable should only be laid directly in earth or water if a protective conduit is used. Permitted operating temperature at conductor +90 C. Conductor Bare copper, solid or stranded, IEC and EN Insulation Special compound, HD 604 S1 part 5 H Filler HD 604 S1 part 5 H Inner sheath Compound, HD 604 S1 part 5 H Armouring [rodent protection] Single core cable with copper tape [CLCU] and multicore cable with galvanised steel tape [CL] Outer sheath Compound, HD 604 S1 part 5 H Core colours CENELEC HD 308 S2 Sheath colour Orange Imprint On request Nominal voltage Test voltage 0.6/1kV 3500V, 50Hz General Properties Minimum bending radius during and permanent installation 15 x D (single core cable) 12 x D (multicore cable) (D = outer diameter) Operating temperature permanent installation -45 C to +90 C during installation -5 C to +50 C pyrofil Keram FE180-CL 0511/e Zero halogen, IEC , EN , VDE , non corrosive gases SEV TP20B/3C Flame propagation IEC , EN , VDE , SEV TP20B/3C Flame spread IEC Cat. C, EN Cat. C, VDE Cat. C, SEV TP20B/3C Smoke density IEC /-2, EN /-2, VDE /-2, SEV TP20B/3C Circuit integrity [FE/PH] IEC /-21 (180 minutes), VDE 0472 part 814 (FE180), SEV TP20B/3C

63 FE180-CL Safety cable 0.6/1kV armoured with rodent protection, pyrofil Keram Halogen-free, with improved fire characteristics with reference to SEV TP 20B/3C and CENELEC HD 604 S1 part 5.H Circuit integrity (FE180) in accordance with IEC Article No. no. of cores x cross section cu content Total weight Outer diameter Fire load n x mm 2 kg/km app. kg/km app. mm kwh/m 3 x 1,5 RE , x 2,5 RE , x 4,0 RE , x 6,0 RE , x 10 RE , x 16 RM ,93 3 x 25 RM ,41 3 x 35 RM ,73 3 x 50 RM ,29 3 x 70 RM ,22 3 x 95 RM ,42 3 x 120 RM ,04 3 x 150 RM ,30 RE = circular, solid conductor RM = circular, stranded conductor Additional dimensions available on request. 61

64 Developed especially for the Swiss market Preventive fire protection FE180-CL Safety cable 0.6/1kV armoured with rodent protection, pyrofil Keram Halogen-free, with improved fire characteristics with reference to SEV TP 20B/3C and CENELEC HD 604 S1 part 5.H Circuit integrity (FE180) in accordance with IEC Article No. no. of cores x cross section cu content Total weight Outer diameter Fire load n x mm 2 kg/km app. kg/km app. mm kwh/m 4 x 1,5 RE , x 2,5 RE , x 4 RE , x 6 RE ,06 4 x 10 RE , x 16 RM , x 25 RM , x 35 RM , x 50 RM , x 70 RM , x 95 RM , x 120 RM ,26 4 x 150 RM , x 1,5 RE , x 2,5 RE , x 4 RE , x 6 RE , x 10 RE , x 16 RM , x 25 RM , x 35 RM , x 50 RM ,83 5 x 70 RM ,05 5 x 95 RM ,14 RE = circular, solid conductor RM = circular, stranded conductor Additional dimensions available on request. 62

65 FE180-CL Safety cable 0.6/1kV armoured with rodent protection, pyrofil Keram Halogen-free, with improved fire characteristics with reference to SEV TP 20B/3C and CENELEC HD 604 S1 part 5.H Circuit integrity (FE180) in accordance with IEC Article No. no. of cores x cross section cu content Total weight Outer diameter Fire load n x mm 2 kg/km app. kg/km app. mm kwh/m 7 x 1,5 RE ,72 7 x 2,5 RE ,91 7 x 4 RE , x 6 RE , x 10 RE , x 1,5 RE , x 2,5 RE , x 4 RE ,36 10 x 1,5 RE ,05 10 x 2,5 RE ,32 12 x 1,5 RE ,12 12 x 2,5 RE ,52 RE = circular, solid conductor RM = circular, stranded conductor Additional dimensions available on request. 21 x 1,5 RE ,71 21 x 2,5 RE ,29 27 x 1,5 RE ,16 27 x 2,5 RE ,87 63

66 FE180 E30-E60 Safety cable 0.6/1kV (N)HXH, pyrofil Keram Halogen-free, with improved fire characteristics With reference to VDE 0266 and CENELEC HD 604 S1 Circuit integrity (FE180) in accordance with VDE , IEC System Circuit integrity E30-E60* in accordance with DIN Filler Flame retardant, zero halogen Fire barrier High-peformance Keram compound Sheath FRNC/LS0H Insulation Crosslinked polymer zero halogen Conductor Solid/ stranded Application Construction are used in all situations that require special protection against fire and flame damage for people and equipment and where a high degree of safety conditions must be fulfilled. Suitable for indoor applications. For outdoor applications, protection must be provided against exposure to direct sunlight. The cable should only be laid directly in earth or water if a protective conduit is used. These cables correspond to the demands of System Circuit integrity E30-E60* in accordance with DIN System Circuit integrity is guaranteed at an operating voltage up to 400V. Permitted operating temperature at conductor +90 C. Conductor Bare copper, solid or stranded, IEC 60228, EN 60228, (VDE 0295) Insulation Double insulation, cross-linked, high-performance Keram special compound, VDE 0266 HXI1 Filler Flame retardant, halogen-free, thermoplastic compound Outer sheath Flame retardant Polyolefin compound, CENELEC HD 604 S1 and VDE HM4 Core colours CENELEC HD 308 S2 and VDE 0293 Sheath colour Orange Imprint Datwyler PYROFIL KERAM (N)HXH FE180 E30-E60 1kV SWISS MADE N X MM 2 VDE REG. NR ORDER NO. YEAR METRE MARKING or on request Electrical Properties Rated voltage Test voltage 0.6/1kV 4000V, 50Hz pyrofil (N)HXH FE180/E30-E60 Keram 0511/e General Properties Minimum bending radius during and permanent installation 15* x D (single core cable) 12* x D (multicore cable) (D = outer diameter) permanent installation *50% reduction if installation at 30 C and with a template Operating temperature permanent installation -45 C to +90 C during installation -5 C to +50 C Zero halogen, non corrosive gases IEC , EN , VDE Flame propagation IEC , EN , VDE Flame spread IEC /-24 Cat. A/C, EN /-24 Cat. A/C, VDE /24 Cat. A/C Smoke density IEC /-2, EN /-2, VDE /-2 Circuit integrity [FE/PH] IEC /-21 (180 minutes), VDE 0472 part 814 (FE180), IEC , IEC (120 minutes ), EN 50200, VDE (PH120) and EN 50362, VDE (120 minutes), BS 6387 C/W/Z System Circuit integrity DIN 4102 part 12, NBN (Rf1) [E30-E60]* * System Circuit integrity is dependent on installation method. 64

67 FE180 E30-E60 Safety cable 0.6/1kV (N)HXH, pyrofil Keram Halogen-free, with improved fire characteristics With reference to VDE 0266 and CENELEC HD 604 S1 Circuit integrity (FE180) in accordance with VDE , IEC System Circuit integrity E30-E60* in accordance with DIN Article No. no. of cores x cross section cu content Total weight Outer diameter Fire load n x mm 2 kg/km app. kg/km app. mm kwh/m x 4 RE ,1 0, x 6 RE ,6 0, x 10 RE ,4 0, x 16 RM ,8 0, x 25 RM ,3 0, x 35 RM ,4 0, x 50 RM ,9 0, x 70 RM ,7 0, x 95 RM ,1 0, x 120 RM ,2 0, x 150 RM ,4 1, x 185 RM ,6 1, x 240 RM ,8 1, x 1,5 RE ,0 0, x 2,5 RE ,8 0, x 4 RE ,8 0, x 6 RE ,8 0, x 10 RE ,4 0, x 16 RM ,2 1, x 25 RM ,2 1, x 1,5 RE ,5 0, x 2,5 RE ,4 0, x 4 RE ,5 0, x 6 RE ,6 0, x 10 RE ,3 0, x 16 RM ,3 1, x 25 RM ,6 1, x 35 RM ,9 1, x 50 RM ,2 2, x 70 RM ,7 2,88 RE = circular, solid conductor RM = circular, stranded conductor Additional dimensions available on request. * Circuit integrity is dependent on installation method 65

68 FE180 E30-E60 Safety cable 0.6/1kV (N)HXH, pyrofil Keram Halogen-free, with improved fire characteristics With reference to VDE 0266 and CENELEC HD 604 S1 Circuit integrity (FE180) in accordance with VDE , IEC System Circuit integrity E30-E60* in accordance with DIN Article No. no. of cores x cross section cu content Total weight Outer diameter Fire load n x mm 2 kg/km app. kg/km app. mm kwh/m x x 16 RM ,9 1, x x 16 RM ,9 1, x x 25 RM ,9 2, x x 35 RM ,0 3, x x 50 RM ,3 4, x x 70 RM ,6 4, x x 70 RM ,6 5, x x 95 RM ,0 6, x 1,5 RE ,4 0, x 2,5 RE ,4 0, x 4 RE ,6 0, x 6 RE ,8 0, x 10 RE ,8 1, x 16 RM ,1 1, x 25 RM ,8 1, x 35 RM ,4 2, x 50 RM ,5 2, x 70 RM ,2 3, x 95 RM ,7 4, x 120 RM ,6 5, x 150 RM ,0 6, x 185 RM ,3 7, x 240 RM ,0 10,05 RE = circular, solid conductor RM = circular, stranded conductor Additional dimensions available on request. * Circuit integrity is dependent on installation method 66

69 FE180 E30-E60 Safety cable 0.6/1kV (N)HXH, pyrofil Keram Halogen-free, with improved fire characteristics With reference to VDE 0266 and CENELEC HD 604 S1 Circuit integrity (FE180) in accordance with VDE , IEC System Circuit integrity E30-E60* in accordance with DIN Article No. no. of cores x cross section cu content Total weight Outer diameter Fire load n x mm 2 kg/km app. kg/km app. mm kwh/m x 1,5 RE ,4 0, x 2,5 RE ,5 0, x 4 RE ,8 0, x 6 RE ,2 1, x 10 RE ,3 1, x 16 RM ,1 1, x 25 RM ,2 2, x 35 RM ,5 2, x 50 RM ,8 3, x 70 RM ,0 4, x 95 RM ,6 5, x 1,5 RE ,4 0, x 2,5 RE ,6 0, x 1,5 RE ,3 1, x 2,5 RE ,0 1, x 1,5 RE ,2 1, x 2,5 RE ,2 1, x 1,5 RE ,6 1, x 2,5 RE ,0 2, x 1,5 RE ,0 2, x 2,5 RE ,8 2,68 RE = circular, solid conductor RM = circular, stranded conductor Additional dimensions available on request. * Circuit integrity is dependent on installation method 67

70 (N)HXCH FE180 E30-E60 Safety cable 0.6/1kV, pyrofil Keram Halogen-free, with improved fire characteristics With reference to VDE 0266 and CENELEC HD 604 S1 Circuit integrity (FE180) in accordance with VDE , IEC System Circuit integrity E30-E60* in accordance with DIN Concentric conductor Bare copper wire Insulation Crosslinked polymer zero halogen Conductor Solid/stranded Sheath FRNC/LS0H Separator Plastic tape Reinforcing helix Bare copper tape Filler Flame retardant, zero halogen Fire barrier High-peformance Keram compound Application Construction are used in all situations that require special protection against fire and flame damage for people and equipment and where a high degree of safety conditions must be fulfilled. Suitable for indoor applications. For outdoor applications, protection must be provided against exposure to direct sunlight. The cable should only be laid directly in earth or water if a protective conduit is used. These cables correspond to the demands of System Circuit integrity E30-E60* in accordance with DIN System Circuit integrity is guaranteed at an operating voltage up to 400V. Permitted operating temperature at conductor +90 C. Conductor Bare copper, solid or stranded, IEC 60228, EN 60228, (VDE 0295) Insulation Double insulation, cross-linked, high-performance Keram special compound, VDE 0266 HXI1 Filler Flame retardant, halogen-free, thermoplastic compound Concentric conductor Bare copper wires with reinforced helix Separator Plastic tape Outer sheath Polyolefin compound, CENELEC HD 604 S1 and VDE HM4 Core colours CENELEC HD 308 S2 and VDE 0293 Sheath colour Orange Imprint Datwyler PYROFIL KERAM (N)HXCH FE180 E30-E60 1kV SWISS MADE N X MM 2 VDE REG. NR ORDER NO. YEAR METRE MARKING or on request pyrofil (N)HXCH FE180/E30-E60 Keram 0511/e Electrical Properties General Properties Nominal voltage Test voltage 0.6/1kV 4000V, 50Hz Minimum bending radius during and permanent installation 15 x D (single core cable) 12 x D (multicore cable) (D = outer diameter) Operating temperature permanent installation -45 C to +90 C during installation -5 C to +50 C Zero halogen, non corrosive gases IEC , EN , VDE Flame propagation IEC , EN , VDE Flame spread IEC /-24 Cat. A/C, EN /-24 Cat. A/C, VDE /24 Cat. A/C Smoke density IEC /-2, EN /-2, VDE /-2 Circuit integrity [FE/PH] IEC /-21 (180 minutes), VDE 0472 part 814 (FE180) IEC , IEC (120 minutes), EN 50200, VDE (PH120) and EN 50362, VDE (120 minutes), BS 6387 C/W/Z System Circuit integrity DIN 4102 part 12 [E30-E60]* * System Circuit integrity is dependent on installation method. 68

71 (N)HXCH FE180 E30-E60 Safety cable 0.6/1kV, pyrofil Keram Halogen-free, with improved fire characteristics With reference to VDE 0266 and CENELEC HD 604 S1 Circuit integrity (FE180) in accordance with VDE , IEC System Circuit integrity E30-E60* in accordance with DIN Article No. no. of cores x cross section cu content Total weight Outer diameter Fire load n x mm 2 kg/km app. kg/km app. mm kwh/m x 1,5 RE/1, ,7 0, x 2,5 RE/2, ,5 0, x 4 RE/ ,0 0, x 6 RE/ ,0 0, x 10 RE/ ,0 1, x 1,5 RE/1, ,2 0, x 2,5 RE/2, ,1 0, x 4 RE/ ,7 0, x 6 RE/ ,8 0, x 10 RE/ ,9 1, x 16 RM/ ,9 1, x 25 RM/ ,0 1, x 35 RM/ ,3 2, x 50 RM/ ,8 2, x 70 RM/ ,0 3, x 95 RM/ ,1 4, x 120 RM/ ,5 5, x 150 RM/ ,2 6, x 185 RM/ ,0 7, x 240 RM/ ,5 9, x 1,5 RE/1, ,1 0, x 2,5 RE/2, ,1 0, x 4 RE/ ,8 0, x 6 RE/ ,1 1, x 10 RE/ ,1 1, x 16 RM/ ,4 1, x 25 RM/ ,2 2, x 35 RM/ ,8 2, x 50 RM/ ,8 3, x 70 RM/ ,5 4, x 95 RM/ ,2 5, x 120 RM/ ,1 6, x 150 RM/ ,3 7, x 185 RM/ ,8 9, x 240 RM/ ,9 12, x 1,5 RE/2, ,1 0, x 1,5 RE/ ,1 2,67 RE = circular, solid conductor, RM = circular, stranded conductor Additional dimensions available on request. * Circuit integrity is dependent on installation method 69

72 (N)HXH CL FE180 E30-E60 Safety cable 0.6/1kV armoured with rodent protection, pyrofil Keram Halogen-free, with improved fire characteristics With reference to VDE 0266 and CENELEC HD 604 S1 Circuit integrity (FE180) in accordance with VDE , IEC System Circuit integrity E30-E60* in accordance with DIN Filler Flame retardant zero halogen Fire barrier High performance Keram special compound Sheath FRNC/LS0H Armouring Galvanised steel tape Inner sheath Polyolefin flame retardant, low smoke, zero halogen Insulation Crosslinked polymer zero halogen Conductor Solid/stranded Application Construction Electrical Properties are used in all situations that require special protection against fire and flame damage for people and equipment and where a high degree of safety conditions must be fulfilled. Suitable for indoor applications. For outdoor applications, protection must be provided against exposure to direct sunlight. The cable should only be laid directly in earth or water if a protective conduit is used. These cables correspond to the demands of circuit integrity E30-E60* in accordance with DIN Circuit integrity is guaranteed at an operating voltage up to 400V. Permitted operating temperature at conductor +90 C. Conductor Bare copper, solid or stranded, IEC 60228, EN 60228, (VDE 0295) Insulation Double insulation, cross-linked, high-performance Keram special compound, VDE 0266 HXI1 Filler Flame retardant, halogen-free, thermoplastic compound Inner sheath Flame retardant Polyolefin compound, CENELEC HD 604 S1 and VDE HM4 Armouring Single core cable with copper tape [CLCU] and multicore cable [rodent protection] with galvanised steel tape [CL] Outer sheath Flame retardant Polyolefin compound, CENELEC HD 604 S1 and VDE HM4 Core colours CENELEC HD 308 S2 and VDE 0293 Sheath colour Orange Imprint Datwyler PYROFIL KERAM (N)HXH CLCU or CL FE180 E30-E60 1kV N X MM2 VDE REG. NR YEAR ORDER NO. SWISS MADE METRE MARKING or on request Nominal voltage Test voltage 0.6/1kV 4000V, 50Hz pyrofil (N)HXH CL FE180/E30-E60 Keram 0511/e General Properties Minimum bending radius during and permanent installation 15 x D (single core cable) 12 x D (multicore cable) (D = outer diameter) Operating temperature permanent installation -45 C to +90 C during installation -5 C to +50 C Zero halogen, non corrosive gases IEC , EN , VDE Flame propagation IEC , EN , VDE Flame spread IEC /-24 Cat. A/C, EN /-24 Cat. A/C, VDE /24 Cat. A/C Smoke density IEC /-2, EN /-2, VDE /-2 Circuit integrity [FE/PH] IEC /-21 (180 minutes), VDE 0472 part 814 (FE180), BS 6387 C/W/Z System Circuit integrity DIN 4102 part 12 [E30-E60]* * System Circuit integrity is dependent on installation method. 70

73 (N)HXH CL FE180 E30-E60 Safety cable 0.6/1kV armoured with rodent protection, pyrofil Keram Halogen-free, with improved fire characteristics With reference to VDE 0266 and CENELEC HD 604 S1 Circuit integrity (FE180) in accordance with VDE , IEC System Circuit integrity E30-E60* in accordance with DIN Article No. no. of cores x cross section cu content Total weight Outer diameter Fire load n x mm 2 kg/km app. kg/km app. mm kwh/m x 1,5 RE , x 2,5 RE , x 4 RE , x 6 RE ,25 2 x 10 RE ,43 2 x 16 RM ,79 2 x 25 RM ,22 2 x 35 RM ,64 2 x 50 RM ,04 2 x 70 RM ,79 2 x 95 RM ,89 2 x 120 RM ,47 2 x 150 RM ,62 2 x 185 RM , x 1,5 RE , x 2,5 RE , x 4 RE , x 6 RE , x 10 RE , x 16 RM ,93 3 x 25 RM ,41 3 x 35 RM ,73 3 x 50 RM ,29 3 x 70 RM ,22 3 x 95 RM ,42 3 x 120 RM ,04 3 x 150 RM ,30 RE = circular, solid conductor RM = circular, stranded conductor Additional dimensions available on request. * Circuit integrity is dependent on installation method 71

74 (N)HXH CL FE180 E30-E60 Safety cable 0.6/1kV armoured with rodent protection, pyrofil Keram Halogen-free, with improved fire characteristics With reference to VDE 0266 and CENELEC HD 604 S1 Circuit integrity (FE180) in accordance with VDE , IEC System Circuit integrity E30-E60* in accordance with DIN Article No. no. of cores x cross section cu content Total weight Outer diameter Fire load n x mm 2 kg/km app. kg/km app. mm kwh/m 4 x 1,5 RE , x 2,5 RE , x 4 RE ,36 4 x 6 RE ,51 4 x 10 RE , x 16 RM , x 25 RM , x 35 RM , x 50 RM ,02 4 x 70 RM ,05 4 x 95 RM ,52 4 x 120 RM , x 1,5 RE , x 2,5 RE , x 4 RE , x 6 RE , x 10 RE , x 16 RM , x 25 RM , x 35 RM , x 50 RM ,83 5 x 70 RM ,05 5 x 95 RM ,14 6 x 1,5 RE ,39 6 x 2,5 RE , x 4 RE ,74 6 x 6 RE ,94 6 x 10 RE ,26 RE = circular, solid conductor RM = circular, stranded conductor Additional dimensions available on request. * Circuit integrity is dependent on installation method 72

75 (N)HXH CL FE180 E30-E60 Safety cable 0.6/1kV armoured with rodent protection, pyrofil Keram Halogen-free, with improved fire characteristics With reference to VDE 0266 and CENELEC HD 604 S1 Circuit integrity (FE180) in accordance with VDE , IEC System Circuit integrity E30-E60* in accordance with DIN Article No. no. of cores x cross section cu content Total weight Outer diameter Fire load n x mm 2 kg/km app. kg/km app. mm kwh/m x 1,5 RE ,38 7 x 2,5 RE , x 4 RE , x 6 RE , x 10 RE ,2 8 x 1,5 RE ,53 8 x 2,5 RE , x 4 RE ,91 10 x 1,5 RE ,78 10 x 2,5 RE ,98 10 x 4 RE ,24 12 x 1,5 RE , x 2,5 RE ,13 12 x 4 RE ,42 14 x 1,5 RE ,07 14 x 2,5 RE , x 1,5 RE ,24 16 x 2,5 RE ,52 21 x 1,5 RE ,58 21 x 2,5 RE ,89 27 x 1,5 RE ,06 27 x 2,5 RE , x 1,5 RE , x 2,5 RE ,81 RE = circular, solid conductor, RM = circular, stranded conductor Additional dimensions available on request. * Circuit integrity is dependent on installation method 73

76 (N)HXH FE180 E90 Safety cable 0.6/1kV, pyrofil Keram Halogen-free, with improved fire characteristics With reference to VDE 0266 and CENELEC HD 604 S1 Circuit integrity (FE180) in accordance with VDE , IEC System Circuit integrity E90 in accordance with DIN Filler Flame retardant, zero halogen Fire barrier High-peformance Keram compound Sheath FRNC/LS0H Insulation Crosslinked polymer zero halogen Conductor Solid/ stranded Application Construction are used in all situations that require special protection against fire and flame damage for people and equipment and where a high degree of safety conditions must be fulfilled. Suitable for indoor applications. For outdoor applications, protection must be provided against exposure to direct sunlight. The cable should only be laid directly in earth or water if a protective conduit is used. These cables correspond to the demands of System Circuit integrity E90 in accordance with DIN System Circuit integrity is guaranteed at an operating voltage up to 400V. Permitted operating temperature at conductor +90 C. Conductor Bare copper, solid or stranded, IEC 60228, EN 60228, (VDE 0295) Insulation Double insulation, cross-linked, high-performance Keram special compound, VDE 0266 HXI1 Filler Flame retardant, halogen-free, thermoplastic compound Outer sheath Flame retardant Polyolefin compound, CENELEC HD 604 S1 and VDE HM4 Core colours CENELEC HD 308 S2 and VDE 0293 Sheath colour Orange Imprint Datwyler PYROFIL KERAM (N)HXH FE180 E90 1kV N X MM2 VDE REG. NR Vds ORDER NO. SWISS MADE YEAR METRE MARKING or on request Electrical Properties Nominal voltage Test voltage 0.6/1kV 4000V, 50Hz pyrofil (N)HXH FE180/E90 Keram 0511/e General Properties Minimum bending radius during and permanent installation 15* x D (single core cable) 12* x D (multicore cable) (D = outer diameter) permanent installation *50% reduction if installation at 30 C and with a template Operating temperature permanent installation -45 C to +90 C during installation -5 C to +50 C Zero halogen, non corrosive gases IEC , EN , VDE Flame propagation IEC , EN , VDE Flame spread IEC /-24 Cat. A/C, EN /-24 Cat. A/C, VDE /24 Cat. A/C Smoke density IEC /-2, EN /-2, VDE /-2 Circuit integrity [FE/PH] IEC /-21 (180 minutes), VDE 0472 part 814 (FE180) IEC , IEC (120 minutes ), EN 50200, VDE (PH120) and EN 50362, VDE (120 minutes), BS 6387 C/W/Z System Circuit integrity [E90] DIN 4102 part 12 System Circuit integrity under effect of water VdS 3423 [single core cable 16mm 2 ] 74

77 (N)HXH FE180 E90 Safety cable 0.6/1kV, pyrofil Keram Halogen-free, with improved fire characteristics With reference to VDE 0266 and CENELEC HD 604 S1 Circuit integrity (FE180) in accordance with VDE , IEC System Circuit integrity E90 in accordance with DIN Article No. no. of cores x cross section cu content Total weight Outer diameter Fire load n x mm 2 kg/km app. kg/km app. mm kwh/m x 16 RM ,2 0, x 25 RM ,7 0, x 35 RM ,8 0, x 50 RM ,3 0, x 70 RM ,1 0, x 95 RM ,5 0, x 120 RM ,6 0, x 150 RM ,8 1, x 185 RM ,0 1, x 240 RM ,2 1, x 300 RM ,6 1, x 1,5 RE ,0 0, x 2,5 RE ,8 0, x 4 RE ,8 0, x 6 RE ,8 0, x 10 RE ,4 0, x 16 RM ,0 1, x 25 RM ,0 1, x 35 RM ,2 1, x 50 RM ,0 2, x 70 RM ,6 2, x 95 RM ,2 3, x 120 RM ,6 4, x 1,5 RE ,5 0, x 2,5 RE ,4 0, x 4 RE ,5 0, x 6 RE ,6 0, x 10 RE ,3 0, x 16 RM ,2 1, x 25 RM ,0 1, x 35 RM ,4 2, x 50 RM ,8 2, x 70 RM ,9 3, x 95 RM ,9 3, x 120 RM ,5 4, x 150 RM ,0 5, x 185 RM ,7 6, x 240 RM ,6 8,10 RE = circular, solid conductor, RM = circular, stranded conductor Additional dimensions available on request. 75

78 (N)HXH FE180 E90 Safety cable 0.6/1kV, pyrofil Keram Halogen-free, with improved fire characteristics With reference to VDE 0266 and CENELEC HD 604 S1 Circuit integrity (FE180) in accordance with VDE , IEC System Circuit integrity E90 in accordance with DIN Article No. no. of cores x cross section cu content Total weight Outer diameter Fire load n x mm 2 kg/km app. kg/km app. mm kwh/m x x 16 RM ,4 2, x x 25 RM ,3 2, x x 35 RM ,6 3, x x 50 RM ,7 4, x x 70 RM ,0 4, x x 70 RM ,0 5, x x 95 RM ,4 7, x 1,5 RE ,4 0, x 2,5 RE ,4 0, x 4 RE ,6 0, x 6 RE ,8 0, x 10 RE ,8 1, x 16 RM ,1 1, x 25 RM ,3 2, x 35 RM ,0 2, x 50 RM ,8 2, x 70 RM ,6 3, x 95 RM ,1 4, x 120 RM ,0 5, x 150 RM ,2 6, x 185 RM ,5 7, x 240 RM ,1 9,85 RE = circular, solid conductor RM = circular, stranded conductor Additional dimensions available on request. 76

79 (N)HXH FE180 E90 Safety cable 0.6/1kV, pyrofil Keram Halogen-free, with improved fire characteristics With reference to VDE 0266 and CENELEC HD 604 S1 Circuit integrity (FE180) in accordance with VDE , IEC System Circuit integrity E90 in accordance with DIN Article No. no. of cores x cross section cu content Total weight Outer diameter Fire load n x mm 2 kg/km app. kg/km app. mm kwh/m x 1,5 RE ,4 0, x 2,5 RE ,5 0, x 4 RE ,8 0, x 6 RE ,2 1, x 10 RE ,3 1, x 16 RM ,8 1, x 25 RM ,8 2, x 35 RM ,0 2, x 50 RM ,5 3, x 70 RM ,5 4, x 1,5 RE ,4 0, x 2,5 RE ,6 0, x 4 RE ,1 1, x 1,5 RE ,8 1, x 2,5 RE ,4 1, x 1,5 RE ,3 1, x 2,5 RE ,0 1, x 1,5 RE ,6 1,99 RE = circular, solid conductor RM = circular, stranded conductor Additional dimensions available on request. 77

80 (N)HXCH FE180 E90 Safety cable 0.6/1kV, pyrofil Keram Halogen-free, with improved fire characteristics With reference to VDE 0266 and CENELEC HD 604 S1 Circuit integrity (FE180) in accordance with VDE , IEC System Circuit integrity E90 in accordance with DIN Concentric conductor Bare copper wire Insulation Crosslinked polymer zero halogen Conductor Solid/stranded Sheath FRNC/LS0H Separator Plastic tape Reinforcing helix Bare copper tape Filler Flame retardant, zero halogen Fire barrier High-peformance Keram compound pyrofil (N)HXCH FE180/E90 Keram 0511/e Application Construction Electrical Properties General Properties are used in all situations that require special protection against fire and flame damage for people and equipment and where a high degree of safety conditions must be fulfilled. Suitable for indoor applications. For outdoor applications, protection must be provided against exposure to direct sunlight. The cable should only be laid directly in earth or water if a protective conduit is used. These cables correspond to the demands of System Circuit integrity E90 in accordance with DIN System Circuit integrity is guaranteed at an operating voltage up to 400V. Permitted operating temperature at conductor +90 C. Conductor Bare copper, solid or stranded, IEC 60228, EN 60228, (VDE 0295) Insulation Double insulation, cross-linked, high-performance Keram special compound, VDE 0266 HXI1 Filler Halogen-free compound or plastic tape Concentric conductor Bare copper wires with reinforced helix Separator Plastic tape Outer sheath Polyolefin compound, CENELEC HD 604 S1 and VDE HM4 Core colours CENELEC HD 308 S2 and VDE 0293 Sheath colour Orange Imprint Datwyler PYROFIL KERAM (N)HXCH FE180 E90 1kV N X MM 2 VDE REG. NR VDS ORDER NO. YEAR SWISS MADE METRE MARKING or on request Nominal voltage Test voltage 0.6/1kV 4000V, 50Hz Minimum bending radius during and permanent installation 12 x D (multicore cable) (D = outer diameter) Operating temperature permanent installation -45 C to +90 C during installation -5 C to +50 C Zero halogen, non corrosive gases IEC , EN , VDE Flame propagation IEC , EN , VDE Flame spread IEC /-24 Cat. A/C, EN /-24 Cat. A/C, VDE /24 Cat. A/C Smoke density IEC /-2, EN /-2, VDE /-2 Circuit integrity [FE/PH] IEC /-21 (180 minutes), VDE 0472 part 814 (FE180) IEC , IEC (120 minutes ), EN 50200, VDE (PH120) and EN 50362, VDE (120 minutes), BS 6387 C/W/Z System Circuit integrity [E90] DIN 4102 part 12 System Circuit integrity under effect of water VdS 3423 [n x 16mm 2 ] 78

81 (N)HXCH FE180 E90 Safety cable 0.6/1kV, pyrofil Keram Halogen-free, with improved fire characteristics With reference to VDE 0266 and CENELEC HD 604 S1 Circuit integrity (FE180) in accordance with VDE , IEC System Circuit integrity E90 in accordance with DIN Article No. no. of cores x cross section cu content Total weight Outer diameter Fire load n x mm 2 kg/km app. kg/km app. mm kwh/m x 1,5 RE/1, ,2 0, x 2,5 RE/2, ,1 0, x 4 RE/ ,7 0, x 6 RE/ ,8 0, x 10 RE/ ,6 1, x 16 RM/ ,4 1, x 25 RM/ ,8 1, x 35 RM/ ,2 2, x 50 RM/ ,5 2, x 70 RM/ ,1 3, x 95 RM/ ,0 4, x 120 RM/ ,4 5, x 150 RM/ ,7 6, x 185 RM/ ,0 7, x 240 RM/ ,1 9, x 1,5 RE/1, ,1 0, x 2,5 RE/2, ,1 0, x 4 RE/ ,8 0, x 6 RE/ ,1 1, x 10 RE/ ,1 1, x 16 RM/ ,3 1, x 25 RM/ ,9 2, x 35 RM/ ,6 2, x 50 RM/ ,7 3, x 70 RM/ ,3 4, x 95 RM/ ,4 5, x 120 RM/ ,1 6, x 150 RM/ ,3 7, x 185 RM/ ,8 9, x 240 RM/ ,2 11, x 1,5 RE/2, ,1 0, x 2,5 RE/2, ,3 1, x 1,5 RE/2, ,2 1, x 2,5 RE/ ,6 1, x 1,5 RE/ ,4 2, x 2,5 RE/ ,6 2, x 1,5 RE/ ,1 2, x 2,5 RE/ ,2 3,11 RE = circular, solid conductor RM = circular, stranded conductor Additional dimensions available on request. 79

82 JE-H(St)H...Bd FE180 E30 L Wiring cable for industrial electronics max. 225V, pyrofil Keram Halogen-free, with improved fire characteristics with reference to VDE 0815 Circuit integrity (FE180) in accordance with VDE , IEC 60331, EN System Circuit integrity E30 in accordance with DIN Separator Plastic tape zero halogen Insulation Crosslinked polymer zero halogen Sheath FRNC/LS0H Shielding Al-laminated tape zero halogen Drain wire Ø 0,8 mm Conductor Solid Application Construction are used in all situations that require special protection against fire and flame damage for people and equipment and where a high degree of safety conditions must be fulfilled. Suitable for indoor applications. For outdoor applications, protection must be provided against exposure to direct sunlight. The cable should only be laid directly in earth or water if a protective conduit is used. These cables correspond to the demands of System Circuit integrity E30 in accordance with DIN System Circuit integrity is guaranteed at an operating voltage up to 110V. Permitted operating temperature at conductor +70 C. Conductor Bare copper, solid, 0.8mm diameter, VDE 0815 Insulation Fire-resistant, crosslinked, high-performance Keram special compound, EN Core colours VDE 0815, bundles identified by numbered tape Separator PEPT Plastic Tape Shielding Al-laminated tape with tinned copper drain wire Ø 0.8mm Outer sheath Flame retardant polyolefin compound VDE 0819 part 107, EN and VDE HM 2 Sheath colour Orange Imprint Datwyler Pyrofil Keram JE-H(St)H...Bd FE180 E30 L n x 2 x mm VDE Reg. No.9361 ORDER NO. SWISS MADE metre marking or on request Electrical Properties Insulation resistance Loop resistance Capacitance unbalance Capacitance coupling Rated voltage Test voltage min. 100 MΩ x km max Ω/km at 0.80 mm max. 120 nf/km at 800 Hz K max. 200 pf/100m at 800 Hz max. 225 V 500 V, 50 Hz Core/Core 2000 V, 50Hz, Core/Screen pyrofil JE-H(St)H...Bd FE180/E30- L Keram 0511/e General Properties Minimum bending radius during installation 7,5 x D (D = outer diameter) permanent installation 2,5 x D Crush resistance 1000 N/10 cm Impact 10 Impacts Operating temperature permanent installation -30 C to +70 C during installation -5 C to +50 C Zero halogen, non corrosive gases IEC , EN , VDE Flame propagation IEC , EN , VDE Flame spread IEC /-24 Cat. A/C, EN /-24 Cat. A/C, VDE /24 Cat. A/C Smoke density IEC /-2, EN /-2, VDE /-2 Circuit integrity [FE/PH] IEC /-21 (180 minutes), VDE 0472 part 814 (FE180) IEC , EN 50200, VDE System Circuit integrity [E30] DIN 4102 part 12, NBN

83 JE-H(St)H...Bd FE180 E30 L Wiring cable for industrial electronics max. 225V, pyrofil Keram Halogen-free, with improved fire characteristics with reference to VDE 0815 Circuit integrity (FE180) in accordance with VDE , IEC 60331, EN System Circuit integrity E30 in accordance with DIN Article No. no. of cores x conductor diameter cu content Total weight Outer diameter Fire load n x mm kg/km app. kg/km app. mm kwh/m x 2 x x 2 x x 2 x Additional dimensions available on request. 81

84 JE-H(St)H...Bd FE180 E30-E90 Wiring cable for industrial electronics max. 225V, pyrofil Keram Halogen-free, with improved fire characteristics with reference to VDE 0815 Circuit integrity (FE180) in accordance with VDE , IEC 60331, EN System Circuit integrity E30-E90* in accordance with DIN Separator Plastic tape zero halogen Insulation Crosslinked polymer zero halogen Sheath FRNC/LS0H Shielding Al-laminated tape zero halogen Drain wire Ø 0,8 mm Conductor Solid Application Construction Electrical Properties are used in all situations that require special protection against fire and flame damage for people and equipment and where a high degree of safety conditions must be fulfilled. Suitable for indoor applications. For outdoor applications, protection must be provided against exposure to direct sunlight. The cable should only be laid directly in earth or water if a protective conduit is used. These cables correspond to the demands of System Circuit integrity E30-E90* in accordance with DIN System Circuit integrity is guaranteed at an operating voltage up to 110V. Permitted operating temperature at conductor +70 C. Conductor Bare copper, solid, 0.8mm diameter, VDE 0815 Insulation Fire-resistant, crosslinked, high-performance Keram special compound, EN Core colours VDE 0815, bundles identified by numbered tape Separator PEPT Plastic Tape Shielding Al-laminated tape with tinned copper drain wire Ø 0.8mm Outer sheath Flame retardant polyolefin compound, VDE 0819 part 107, EN and VDE HM 2 Sheath colour Orange Imprint Datwyler Pyrofil Keram JE-H(St)H...Bd FE180 E30-E90 n x 2 x mm VDE Reg. No.9361 ORDER NO. SWISS MADE metre marking, or on request Insulation resistance min. 100 MΩ x km Loop resistance max Ω/km at 0.80 mm Capacitance unbalance max. 120 nf/km at 800 Hz Capacitance coupling K max. 200 pf/100m at 800 Hz Rated voltage max. 225 V Test voltage 500 V, 50 Hz Core/Core 2000 V, 50Hz, Core/Screen General Properties Minimum bending radius during installation 7,5 x D (D = outer diameter) permanent installation 2,5 x D Crush resistance 1000 N/10 cm Impact 10 Impacts Operating temperature permanent installation -30 C to +70 C during installation -5 C to +50 C pyrofil JE-H(St)H...Bd FE180/E30-E90 Keram 0511/e Zero halogen, non corrosive gases IEC , EN , VDE Flame propagation IEC , EN , VDE Flame spread IEC /-24 Cat. A/C, EN /-24 Cat. A/C, VDE /24 Cat. A/C Smoke density IEC /-2, EN /-2, VDE /-2 Circuit integrity [FE/PH] IEC /-21 (180 minutes), VDE 0472 part 814 (FE180), IEC , EN 50200, VDE System Circuit integrity [E30-E90]* DIN 4102 part 12, NBN (Rf 1 1 / 2 ) * Circuit integrity is dependent on installation method. 82

85 JE-H(St)H...Bd FE180 E30-E90 Wiring cable for industrial electronics max. 225V, pyrofil Keram Halogen-free, with improved fire characteristics with reference to VDE 0815 Circuit integrity (FE180) in accordance with VDE , IEC 60331, EN System Circuit integrity E30-E90* in accordance with DIN Article No. no. of cores x conductor diameter cu content Total weight Outer diameter Fire load n x mm kg/km app. kg/km app. mm kwh/m x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x Additional dimensions available on request. 83

86 JE-H(St)H...Bd FE180 E30 L Fire alarm cable max. 225V, pyrofil Keram Halogen-free, with improved fire characteristics with reference to VDE 0815 Circuit integrity (FE180) in accordance with VDE , IEC 60331, EN System Circuit integrity E30 in accordance with DIN Separator Plastic tape zero halogen Insulation Crosslinked polymer zero halogen BRANDMELDEKABEL Sheath FRNC/LS0H Shielding Al-laminated tape zero halogen Drain wire Ø 0,8 mm Conductor Solid Application Construction are used in all situations that require special protection against fire and flame damage for people and equipment and where a high degree of safety conditions must be fulfilled. Suitable for indoor applications. For outdoor applications, protection must be provided against exposure to direct sunlight. The cable should only be laid directly in earth or water if a protective conduit is used. These cables correspond to the demands of System Circuit integrity E30 in accordance with DIN System Circuit integrity is guaranteed at an operating voltage up to 110V. Permitted operating temperature at conductor +70 C. Conductor Bare copper, solid, 0.8mm diameter, VDE 0815 Insulation Fire-resistant, crosslinked, high-performance Keram special compound, EN Core colours VDE 0815, bundles identified by numbered tape Separator PEPT Plastic Tape Shielding Al-laminated tape with tinned copper drain wire Ø 0.8mm Outer sheath Flame retardant polyolefin compound, VDE 0819 part 107, EN and VDE HM 2 Sheath colour Red Imprint Datwyler Pyrofil Keram Brandmeldekabel JE-H(St)H...Bd FE180 E30 L n x 2 x mm VDE Reg. No.9361 ORDER NO. SWISS MADE metre marking or on request Electrical Properties Insulation resistance Loop resistance Capacitance unbalance Capacitance coupling Rated voltage Test voltage min. 100 MΩ x km max Ω/km at 0.80 mm max. 120 nf/km at 800 Hz K max. 200 pf/100m at 800 Hz max. 225 V 500 V, 50 Hz Core/Core 2000 V, 50Hz, Core/Screen pyrofil JE-H(St)H...Bd FE180/E30 L Keram BMK 0511/e General Properties Minimum bending radius during installation 7,5 x D (D = outer diameter) permanent installation 2,5 x D Crush resistance 1000 N/10 cm Impact 10 Impacts Operating temperature permanent installation -30 C to +70 C during installation -5 C to +50 C Zero halogen, non corrosive gases IEC , EN , VDE Flame propagation IEC , EN , VDE Flame spread IEC /-24 Cat. A/C, EN /-24 Cat. A/C, VDE /24 Cat. A/C Smoke density IEC /-2, EN /-2, VDE /-2 Circuit integrity [FE/PH] IEC /-21 (180 minutes), VDE 0472 part 814 (FE180), IEC , EN 50200, VDE System Circuit integrity [E30] DIN 4102 part 12, NBN

87 JE-H(St)H...Bd FE180 E30 L Fire alarm cable max. 225V, pyrofil Keram Halogen-free, with improved fire characteristics with reference to VDE 0815 Circuit integrity (FE180) in accordance with VDE , IEC 60331, EN System Circuit integrity E30 in accordance with DIN Article No. no. of cores x conductor diameter cu content Total weight Outer diameter Fire load n x mm kg/km app. kg/km app. mm kwh/m x 2 x x 2 x x 2 x Additional dimensions available on request. 85

88 JE-H(St)H...Bd FE180 E30-E90 Fire alarm cable max. 225V, pyrofil Keram Halogen-free, with improved fire characteristics with reference to VDE 0815 Circuit integrity (FE180) in accordance with VDE , IEC 60331, EN System Circuit integrity E30-E90* in accordance with DIN Separator Plastic tape zero halogen Insulation Crosslinked polymer zero halogen BRANDMELDEKABEL Sheath FRNC/LS0H Shielding Al-laminated tape zero halogen Drain wire Ø 0,8 mm Conductor Solid Application Construction Electrical Properties are used in all situations that require special protection against fire and flame damage for people and equipment and where a high degree of safety conditions must be fulfilled. Suitable for indoor applications. For outdoor applications, protection must be provided against exposure to direct sunlight. The cable should only be laid directly in earth or water if a protective conduit is used. These cables correspond to the demands of System Circuit integrity E30-E90* in accordance with DIN System Circuit integrity is guaranteed at an operating voltage up to 110V. Permitted operating temperature at conductor +70 C. Conductor Bare copper, solid, 0.8mm diameter, VDE 0815 Insulation Fire-resistant, crosslinked, high-performance Keram special compound, EN Core colours VDE 0815, bundles identified by numbered tape Separator PEPT Plastic Tape Shielding Al-laminated tape with tinned copper drain wire Ø 0.8mm Outer sheath Flame retardant polyolefin compound, VDE 0819 part 107, EN and VDE HM 2 Sheath colour Red Imprint Datwyler Pyrofil Keram Brandmeldekabel JE-H(St)H...Bd FE180 E30-E90 n x 2 x mm VDE Reg. No.9361 ORDER NO. SWISS MADE metre marking, or on request Insulation resistance min. 100 MΩ x km Loop resistance max Ω/km at 0.80 mm Capacitance unbalance max. 120 nf/km at 800 Hz Capacitance coupling K max. 200 pf/100m at 800 Hz Rated voltage max. 225 V Test voltage 500 V, 50 Hz Core/Core 2000 V, 50Hz, Core/Screen pyrofil JE-H(St)H...Bd FE180/E30-E90 Keram BMK 0511/e General Properties Minimum bending radius during installation 7,5 x D (D = outer diameter) permanent installation 2,5 x D Crush resistance 1000 N/10 cm Impact 10 Impacts Operating temperature permanent installation -30 C to +70 C during installation -5 C to +50 C Zero halogen, non corrosive gases IEC , EN , VDE Flame propagation IEC , EN , VDE Flame spread IEC /-24 Cat. A/C, EN /-24 Cat. A/C, VDE /24 Cat. A/C Smoke density IEC /-2, EN /-2, VDE /-2 Circuit integrity [FE/PH] IEC /-21 (180 minutes), VDE 0472 part 814 (FE180), IEC , EN 50200, VDE System Circuit integrity DIN 4102 part 12, NBN (Rf 1 1 / 2 ) [E30-E90]* * Circuit integrity is dependent on installation method. 86

89 JE-H(St)H...Bd FE180 E30-E90 Fire alarm cable max. 225V, pyrofil Keram Halogen-free, with improved fire characteristics with reference to VDE 0815 Circuit integrity (FE180) in accordance with VDE , IEC 60331, EN System Circuit integrity E30-E90* in accordance with DIN Article No. no. of cores x conductor diameter cu content Total weight Outer diameter Fire load n x mm kg/km app. kg/km app. mm kwh/m x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x Additional dimensions available on request. 87

90 JE-H(St)HRH...Bd FE180 E30-E90 Fire alarm cable with steel wire braiding max. 225V, pyrofil Keram Halogen-free, with improved fire characteristics with reference to VDE 0815 Circuit integrity (FE180) in accordance with VDE , IEC 60331, EN System Circuit integrity E30-E90* in accordance with DIN Separator Plastic tape zero halogen Insulation Crosslinked polymer zero halogen BRANDMELDEKABEL Sheath FRNC/LS0H Armouring Galvanised steel wire braid Shielding Al-laminated tape zero halogen Drain wire Ø 0,8 mm Conductor Solid pyrofil JE-H(St)HRH...Bd FE180/E30-E90 Keram 0511/e Application Construction Electrical Properties General Properties are used in all situations that require special protection against fire and flame damage for people and equipment and where a high degree of safety conditions must be fulfilled. Suitable for indoor applications. For outdoor applications, protection must be provided against exposure to direct sunlight. The fire alarm cables correspond to the demands of System Circuit integrity E30-E90* in accordance with DIN System Circuit integrity is guaranteed at an operating voltage up to 110V. The steel wire braiding serves as a form of mechanical protection. Permitted operating temperature at conductor of +70 C. Conductor Bare copper, solid, 0.8mm diameter, VDE 0815 Insulation Fire-resistant, crosslinked, high-performance Keram special compound, EN Core colours According to VDE 0815, bundles identified by numbered tape Separator PEPT Plastic Tape Shielding Al-laminated tape with tinned copper drain wire Ø 0.8mm Inner sheath Flame retardant polyolefin compound, VDE 0819 part 107, EN and VDE HM2 Armouring Galvanised steel wire braid Outer sheath Flame retardant polyolefin compound, VDE 0819 part 107, EN and VDE HM 2 Sheath colour Red Imprint Datwyler Pyrofil Keram Brandmeldekabel JE-H(St)HRH...Bd FE180 E30-E90 n x 2 x mm ORDER NO. SWISS MADE metre marking, or on request Insulation resistance min. 100 MΩ x km Loop resistance max Ω/km at 0.80 mm Capacitance unbalance max. 120 nf/km bei 800 Hz Capacitance coupling K max. 200 pf/100m at 800 Hz Rated voltage max. 225 V Test voltage 500 V, 50 Hz Core/Core 2000 V, 50Hz, Core/Screen Minimum bending radius during installation 7,5 x D (D = outer diameter) permanent installation 2,5 x D Crush resistance 1000 N/10 cm Impact 10 Impacts Operating temperature permanent installation -30 C to +70 C during installation -5 C to +50 C Zero halogen, non corrosive gases IEC , EN , VDE Flame propagation IEC , EN , VDE Flame spread IEC /-24 Cat. A/C, EN /-24 Cat. A/C, VDE /24 Cat. A/C Smoke density IEC /-2, EN /-2, VDE /-2 Circuit integrity [FE/PH] IEC /-21 (180 minutes), VDE 0472 part 814 (FE180), IEC , EN 50200, VDE System Circuit integrity DIN 4102 part 12 [E30-E90]* * Circuit integrity is dependent on installation method. 88

91 JE-H(St)HRH...Bd FE180 E30-E90 Fire alarm cable with steel wire braiding max. 225V, pyrofil Keram Halogen-free, with improved fire characteristics with reference to VDE 0815 Circuit integrity (FE180) in accordance with VDE , IEC 60331, EN System Circuit integrity E30-E90* in accordance with DIN Article No. no. of cores x conductor diameter cu content Total weight Outer diameter Fire load n x mm kg/km app. kg/km app. mm kwh/m 1 x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x Additional dimensions available on request. 89

92 ZGGFR-Safety / U-DQ(ZN)BH Safety cable for indoor and outdoor use nonmetallic, water resistant, rodent protected, flame redardant in accordance with IEC and IEC Cat. C functional integrity with reference to DIN Min. (E30) ripcord FR/LS0H sheath glass armouring flame retardant protective coatings 12 fibres GF-1323 ZGGFR-Safety 1108/e Features Application Optical characteristics Mechanical characteristics General characteristics Fibre-optic safety cable in metal-free central tube design with up to twelve fibres. The optimum matching of fibre coating and flame-inhibiting stabilizing elements ensures functional integrity for 30 minutes. Safety applications in tunnels, underground railways, banks, insurance companies, large scale industry LAN backbones Indoor and outdoor use Can be laid on cable platforms, parapet ducts and vertical shafts Can be spliced in cable terminal distributors The cables are available with different types of Optofil-Safety fibre (see fibre data sheets) temperature range storage -25 / +70 C IEC F1 pulling in -10 / +50 C operation -25 / +60 C tensile performance IEC E1 crush resistance IEC E3 repeated bending IEC E6 torsion IEC E7 bend IEC E11 water penetration IEC F5 Printing example DÄTWYLER OPTOFIL SAFETY 12E9 G.652D FR/LSOH DIN (30) IEC (180) C-no ~ ~ 2480 m ~ ~ SWISS MADE Zero halogen, non corrosive gases IEC /-2, EN /-2-2, VDE /-2-2 Flame propagation IEC , EN , VDE Flame spread IEC Cat.C, EN Cat. C, VDE Cat.C Smoke density IEC /-2, EN /-2, VDE /-2 Circuit integrity IEC /-25 (180 minutes), VDE 0472 part 814, EN 50200, VDE System Circuit integrity with reference to DIN 4102 part 12 [E30]* *Circuit integrity is dependent on installation method. 90

93 ZGGFR-Safety / U-DQ(ZN)BH Safety cable for indoor and outdoor use nonmetallic, water resistant, rodent protected, flame redardant in accordance with IEC and IEC Cat. C functional integrity with reference to DIN Min. (E30) description no. of fibres loose tube cableø weight bending radius tensile load crush resistance fire load U-DQ(ZN)BH 1xm max. max. mm kg/km mm N continuous N/cm short term N/cm kwh/km MJ/km ZGGFR-Safety 1x Versions U-DQ(ZN)BH 1xm fibre article No. article No. article No. article No. description numbe E9/125 G.652.D G50/125 OM2 G50/125 OM3 G62.5/125 OM1 ZGGFR-Safety 1x ZGGFR-Safety 1x ZGGFR-Safety 1x8 8 on request on request on request ZGGFR-Safety 1x

94 wbggfr-safety / U-DQ(ZN)BH Safety cable for indoor and outdoor use nonmetallic, water resistant, rodent protected, flame redardant in accordance with IEC and IEC Cat. C functional integrity with reference to DIN Min. (E30) ripcord FR/LS0H sheath glass armouring flame retardant protective coatings 12 fibres GF-1324 optofil -wbggfr-safety 1108/e Features Application Optical characteristics Mechanical characteristics General characteristics Fibre-optic safety cable in metal-free central tube design with up to twelve fibres. The optimum matching of fibre coating and flame-inhibiting stabilizing elements ensures functional integrity for 30 minutes. Safety applications in tunnels, underground railways, banks, insurance companies, large scale industry LAN backbones Indoor and outdoor use Can be laid on cable platforms, parapet ducts and vertical shafts Can be spliced in cable terminal distributors The cables are available with different types of Optofil-Safety fibre (see fibre data sheets) temperature range storage -25 / +70 C IEC F1 pulling in -10 / +50 C operation -25 / +60 C tensile performance IEC E1 crush resistance IEC E3 repeated bending IEC E6 torsion IEC E7 bend IEC E11 water penetration IEC F5 Printing example DÄTWYLER OPTOFIL SAFETY 60E9 G.652D FR/LSOH DIN (30) IEC (180) C-no ~ ~ 2480 m ~ ~ SWISS MADE Zero halogen, non corrosive gases IEC /-2, EN /-2-2, VDE /-2-2 Flame propagation IEC , EN , VDE Flame spread Smoke density IEC /-2, EN /-2, VDE /-2 Circuit integrity IEC /-25 (180 minutes), VDE 0472 part 814, EN 50200, VDE IEC Cat.C, EN Cat. C, VDE Cat.C System Circuit integrity with reference to DIN 4102 part 12 [E30]* *Circuit integrity is dependent on installation method. 92

95 wbggfr-safety / U-DQ(ZN)BH Safety cable for indoor and outdoor use nonmetallic, water resistant, rodent protected, flame redardant in accordance with IEC and IEC Cat. C functional integrity with reference to DIN Min. (E30) description no. of fibres loose tube cableø weight bending radius tensile load crush resistance fire load U-DQ(ZN)BH nxm max. max. mm kg/km mm N continuous N/cm short term N/cm kwh/km MJ/km wbggfr-safety 2x wbggfr-safety 3x wbggfr-safety 4x wbggfr-safety 5x Versions U-DQ(ZN)BH nxm fibre article No. article No. article No. article No. description number E9/125 G.652.D G50/125 OM2 G50/125 OM3 G62.5/125 OM1 wbggfr-safety 2 x on request wbggfr-safety 3 x on request on request on request wbggfr-safety 4 x on request wbggfr-safety 5 x on request on request 93

96 Cable duct I30 (Hermannkanal) HSK I 30 Application Technical Data Cable duct system for exposure to fire from inside to outside, for prevention of fire propagation on cabling systems in floors and stairwells. Installation with screw set directly onto multi cable support (Hermann clamp). Spacing of fixation 600 mm. Material Light construction fire protection plate Colour White, impregnated Approvals ABP No.: P-3015 / 6930 MPA BS Dimensions Outside (W x H): 170 x 195 mm Inside: 120 x 170 mm Cable duct I30 (Hermannkanal) with installation set (1-3 pcs. multi cable support/hermann clamp and fire safety plug KDM 30 mm). Drill and installation tools are not included. Recommended drill SDS 1, recommended installation tool SWM-SM 50. Article No. type info pu HSK I 30/1200 L= 1200 mm 1 Set HSK I 30/600 L= 600 mm 1 Set HSK I 30/400 L= 400 mm 1 Set HSK I 30/B90 90 right-hand angle 1 Set HSK I 30/B90 90 left-hand angle 1 Set HSK I 30/B45 45 right-hand angle 1 Set HSK I 30/B45 45 left-hand angle 1 Set HSK I 30/Cross 1 Set HSK I 30/T joint 1 Set HSK I 30/End part 1 Piece Additional multi cable support (Hermann clamp) for I30 duct (Hermannkanal) Article No. type info pu SHUD Hermann clamp 10 Fire protection paint Article No. type info pu pyroplast-s 100 D Fire protection paint 15 kg plastic bucket Fire protection filler Article No. type info pu pyroplast-s 100 SM-K Fire protection filler 10 cartridges/310ml 94

97 WUM Support measure For vertical cable installation Application Goods supplied Note Function Installation Effective support measure for vertical installation of pyrofil cables with circuit integrity in accordance with DIN , using the C-shaped rail 2970 SLD. Meandering cable laying is not necessary if the WUM is used at intervals of up to 3.5 m. Fire protection housing Fastening set Fire protection filler S 100 SM-K Mineral wool The WUM E30 and E90 can be used with all pyrofil Keram cable types (N)HXH/(N)HXCH FE180/E30-E60, (N)HXH/(N)HXCH FE180/E90, JE-H(St)H FE180/E30-E90 and JE-H(St)HRH FE180/E30-E90. The WUM protects the clamp of pyrofil safety cables with circuit integrity, thereby supporting the vertical cabling system in the event of fire. The WUM is slipped over the strap clamp that attaches the cable to the C-shaped rail at intervals of up to 3.5 m. It is attached to the C-shaped rail by means of slide nuts and threaded rods.hollow spaces are filled with mineral wool. The cable inlet and back of the WUM are sealed with pyroplast fire protection filler S 100 SM-K. Article No. type outer dimensions for C-shaped rail 2970 Sld pu mm width mm WUM 300 E x 370 x WUM 400 E x 470 x WUM 500 E x 570 x WUM 300 E x 470 x WUM 400 E x 570 x WUM 500 E x 670 x

98 Wire mesh cable tray Application Technical Data Wire mesh cable tray For laying single and multiple cables under ceilings or on walls. Circuit integrity is achieved for pyrofil Keram cable types (N)HXH/(N)HXCH FE180/E30-E60. Maximum permissible fixing distance up to 1250mm. Max. load - 10 kg/m Material Steel wire, mesh 50x100mm, flange height 54mm, Corrosion protection Galavanised (electrolytic) in accordance with DIN (zinc layer µ). Others on request Approvals VDE 0639, CEI 1537 Article No. type nominal width [mm] kg/m pu GR ,29 3 m GR ,53 3 m GR ,77 3 m Note: For cutting, a bolt cutter with offset cutting has to be used. Ceiling console, screwless Corrosion protection: Sendzimir galvanised in accordance with DIN (zinc coating app. 21µ). Other on request Article No. type Height x width [mm] for kg/piece pu GR DKS 150 app. 210 x 230 GR , GR DKS 200 app. 210 x 280 GR , GR DKS 300 app. 210 x 380 GR ,87 1 Wall console, screwless Corrosion protection: Sendzimir galvanised in accordance with DIN (zinc coating app. 21µ). Other on request Article No. type Height x width [mm] for kg/piece pu GR WKS 150 app. 170 x 230 GR , GR WKS 200 app. 170 x 280 GR , GR WKS 300 app. 170 x 380 GR ,

99 Wire mesh cable tray Wire mesh cable tray accessories Article No. type description info GR VB ED 275 and KITASSTR Contents: 50 push connectors ED Snap connectors KITASSTR for straight joints For each push connection provided: - 10 pcs KITASSTR - 2 pcs ED 275 for 90 angles For each 90 angle for barred groove 100 provided: - 6 pcs KITASSTR - 1,5 pcs ED 275 For each 90 angle for barred groove 150/200 provided: - 8 pcs KITASSTR - 2 pcs ED 275 for T-junctions For each T-junction for a barred groove provided: - 4 pcs KITASSTR for cross joints For each T-junction for a barred groove provided: - 6 pcs KITASSTR - 2 pcs ED 275 Wire mesh cable tray fixings Article No. type description info GAS 8x220 thread suspension For thread attachment to ceiling console GR DKS set M8x220 Contents: 13 thread rails M8x1000, 50 KMu LF8 plugs, 100 underlay disks, nuts M8 (recommended tool set SMu 8 SM, drillbit SDS2) GS 8x1000 thread rod For thread attachment to wall console GR WKS M8x1000 PU 50 pieces GZS thread rod for thread rod suspension attachment attachment GS 8x1000 accessories Contents: 100 underlay disks M8 nuts, KMu LF8 plugs, (recommended tool set SMu 8 SM, drillbit SDS2) 97

100 Cable tray without threaded rod suspension Application Technical Data Cable tray For laying single and multiple cables under ceilings or on walls. Circuit integrity is achieved for pyrofil Keram cable types (N)HXH/(N)HXCH FE180/E30-E60, (N)HXH/(N)HXCH FE180/E90, JE-H(St)H FE180/E30-E90, JE-H(St)HRH FE180/E30-E90. This cable tray system needs no threaded rod suspensions for circuit integrity. Maximum permissible fixing distance up to 1500 mm. Max. load - 20 kg/m. Material Nominal size Steel galavanised 60 x 100 mm, 60 x 200 mm, 60 x 300 mm, 60 x 400 mm Article No. type nominal size pu RG 60-10S 100 mm 1 piece = 3 m RG 60-20S 200 mm 1 piece = 3 m RG 60-20S 45 angle 200 mm 1 piece RG 60-30S 300 mm 1 piece = 3 m RG 60-40S 400 mm 1 piece = 3 m Lateral connector RGV-BS 60S 60 mm 1 piece Bottom connector VB-BS 10S 100 mm 1 piece VB-BS 20S 200 mm 1 piece VB-BS 30S 300 mm 1 piece VB-BS 40S 400 mm 1 piece Screws for fixing the tray on the console screw set KLAR M6 100 pieces Lateral reinforcement in the area of consols ALS-BS S 1 piece 98

101 Cable tray Plugs Article No. type nominal size pu M10x10 SD 10/10 M10x pieces Wall consoles KWMS 010F 100 mm 1 piece KWMS 020F 200 mm 1 piece KWMS 030F 300 mm 1 piece KWMS 040F 400 mm 1 piece Consoles for hangers KUMS 010F 100 mm 1 piece KUMS 020F 200 mm 1 piece KUMS 030F 300 mm 1 piece KUMS 040F 400 mm 1 piece Hangers KDU 52-03F 300 mm 1 piece KDU 52-04F 400 mm 1 piece KDU 52-05F 500 mm 1 piece KDU 52-06F 600 mm 1 piece KDU 52-07F 700 mm 1 piece KDU 52-08F 800 mm 1 piece KDU 52-09F 900 mm 1 piece KDU 52-10F 1000 mm 1 piece to fix the consoles on hangers ring washer US 10x21 M10x pieces nut SEM 10 M pieces screw KLS 10x20 M10x pieces 99

102 Single clamp Type SAS Fixing distance 600 mm Fig.1: Type SAS single clamp Fig.2: Type SAS pre-assembled single clamp with fire protection plugs type K6x5 Application Type SAS (Fig.1) Article No. clamp type cable-ø [mm] pu SAS 6 D pcs SAS 8 D pcs SAS 10 D pcs SAS 12 D pcs SAS 14 D pcs SAS 16 D pcs SAS 18 D pcs SAS 20 D pcs SAS 22 D pcs SAS 24 D pcs SAS 26 D pcs SAS 28 D pcs SAS 30 D pcs SAS 38 D new pcs SAS 47 D new pcs SAS 55 D new pcs SAS 60 D new pcs. To attach the single clamp, we recommend the use of Datwyler fire protection plugs K6x5 and the Datwyler tool set SMu 6 SM for quick assembly. Type SAS pre-assembled single clamp with fire protection plugs type K6x5, 30 mm (Fig.2) SAS 8 D - K6x pcs SAS 12 D - K6x pcs SAS 14 D - K6x pcs SAS 16 D - K6x pcs. Required tool set SMu 6 SM. The required SDS1 32 mm drillbit is included in the set. For laying single and multiple cables on ceilings or walls. Circuit integrity is achieved for pyrofil Keram cable types (N)HXH/(N)HXCH FE180/E30-E60, (N)HXH/(N)HXCH FE180/E90, JE-H(St)H FE180/E30-E90, JE-H(St)HRH FE180/E30-E90. Type SAS V4A steel grade (simillar to Fig.1) (ask also for stainless steel plugs) SAS 19 D - V4A pcs. SAS 24 D - V4A pcs. SAS 29 D - V4A pcs. SAS 38 D - V4A pcs. SAS 47 D - V4A pcs. SAS 55 D - V4A pcs. SAS 63 D - V4A pcs. Please also see our optional installation methods: Installation of cable bundles in clamps, installation in steel armoured conduits, etc. 100

103 Strap clamp Type B without trough (LW) Fixing distance mm Type B strap clamp without trough C-shaped rail 2970/2SLD Application Article No. clamp type cable ø [mm] pu B 12 D pcs B 14 D pcs B 16 D pcs B 18 D pcs B 22 D pcs B 26 D pcs B 30 D pcs B 34 D pcs B 38 D pcs B 42 D pcs B 46 D pcs B 50 D pcs B 54 D pcs B 58 D pcs B 64 D pcs B 70 D pcs B 76 D pcs B 82 D pcs B 90 D pcs B 100 D pcs B 110 D pcs. The C-shaped rail 2970/2 SLD is required to fix the strap clamps. For laying several cables independently in parallel on ceilings and walls. Circuit integrity is achieved for pyrofil Keram cable types (N)HXH/(N)HXCH FE180/E30-E60, (N)HXH/(N)HXCH FE180/E90, JE-H(St)H FE180/E30-E90, JE-H(St)HRH FE180/E30-E90. Article No. c-shaped rail Slit width pu /2 SLD 16 mm as required For assembly of the C-shaped rail, we recommend fire protection plugs KDM, 30 mm. Do not exceed the maximum tensile force on the fire protection plugs! Shaped rails come in 2 m lengths. Other lengths are available on request. For fast assembly of the shaped rail, we recommend the tool set SWM-SM. Please also see our optional installation methods: Installation of cable bundles in clamps, installation in steel armoured conduits, etc. 101

104 Strap clamp Type B with trough (LW) Fixing distance 800 mm Type B strap clamp with trough C-shaped rail 2970/2SLD Application For laying several cables independently or in bundles in parallel on ceilings and walls. Circuit integrity is achieved for pyrofil Keram cable types (N)HXH/(N)HXCH FE180/E30-E60, (N)HXH/(N)HXCH FE180/E90, JE-H(St)H FE180/E30-E90, JE-H(St)HRH FE180/E30-E90 (800 mm). Article No. clamp type cable ø [mm] pu B 16 D 100 pcs LW 16 D pcs B 22 D 100 pcs LW 22 D pcs B 26 D 100 pcs LW 26 D pcs B 34 D 100 pcs LW 34 D pcs B 38 D 100 pcs LW 38 D pcs B 42 D 100 pcs LW 42 D pcs B 46 D 100 pcs LW 46 D pcs B 50 D 50 pcs LW 50 D pcs B 54 D 50 pcs LW 54 D pcs. The C-shaped rail 2970/2 SLD is required to fix the strap clamps. Article No. Shaped rail Slit width pu /2 SLD 16 mm as required For assembly of the C-shaped rail, we recommend fire protection plugs KDM, 30 mm. Do not exceed the maximum tensile force on the fire protection plugs! Shaped rails come in 2 m lengths. Other lengths are available on request. For fast assembly of the shaped rail, we recommend the Datwyler tool set SWM-SM. Please also see our optional installation methods: Installation of cable bundles in clamps, installation in steel armoured conduits, etc. 102

105 Multi cable support E30-E90 Hermann clamp for wall and ceiling installation Fixing distance 800 mm / 600 mm* Multi cable support E30-E90 Type Hermann clamp Multi cable support E30-E90 Type Hermann clamp S Application Goods supplied Technical Data For laying multiple cables on ceilings or walls. Circuit integrity is achieved for pyrofil Keram cable types (N)HXH/(N)HXCH FE180/E30-E60, (N)HXH/(N)HXCH FE180/E90, JE-H(St)H FE180/E30-E90, JE-H(St)HRH FE180/E30-E90. Article No and Article No Set consists of 10 SHUD multi cable supports (Hermann clamps), including 10 fire protection plugs KDM, 30 mm. Drill bit and tool set supplied separately. Recommended drill bit SDS1, recommended tool set SWM-SM 50. Article No Stainless steel plugs on request. Hermann clamp Hermann clamp S Material Sendzimir galvanised sheet Sendzimir galvanised sheet Inner dimensions app. 110 mm x 75mm x 80mm app. 70 mm x 52 mm x 56 mm Outer dimensions app. 125 mm x 95mm x 80mm app. 84 mm x 73 mm x 56 mm Maximum load 6 kg/m or 3 kg/m* 3 kg/m* Fixing distance 800 mm or 600 mm* 800 mm or 600 mm* Article No. clamp type pu Hermann clamp 10 pieces Hermann clamp 750 pieces/skeleton box Hermann clamp S 10 pieces Hermann clamp S 1750 pieces/skeleton box Hermann clamp V2A (1.4301) 10 pieces Hermann clamp V4A (1.4571) 10 pieces Hermann clamp S V4A (1.4571) 10 pieces For quick assembly of the SHUD Hermann clamp we recommend the tool set SWM-SM 50. *Please also see our optional installation methods: Installation of cable bundles in clamps, installation in steel armoured conduits, etc. 103

106 End coated mineral fibre plate MFP Identification sign Application Used to form a bulkhead for cable wall and ceiling penetration against the effects of fire for a period of 90 minutes in accordance with DIN (fire resistance class S90/S120). Article No. bulkhead application info Mineral fibre plate For provision of a S90 Single-side end coated pyroplast-s 100 P bulkhead in ceilings and Set consists of 5 plates walls in accordance with DIN (Dimensions: 5 x 0.3 m 2 ) in box = 1.5 m Fire protection paint For coating mineral- 15 kg plastic bucket white, pyroplast-s 100 D fibre plates and technical with carry handle cables on bulkhead exit water-based, solvent free Fire protection filler For closing gaps 5 kg plastic bucket, white, pyroplast-s 100 SM and cracks and wall with carry handle soffits water-based, solvent free Fire protection filler For finishing off 310 ml cartridge, white pyroplast-s 100 SM-K gaps and cracks Set consists of 12 cartridges and wall soffits water-based, solvent free Identification sign For permanent identification Set consists of for flat bulkhead of a cable bulkhead 10 identification signs in accordance with DIN

107 Plugs / Identification sign Application Used to form a bulkhead for cable wall and ceiling penetration against the effects of fire for a period of 90 minutes in accordance with DIN (fire resistance class S90). Article No. bulkhead application info Fire protection plug For provision of a round Packaging comprises 20 pieces BDS S90 bulkhead in ceilings and For bore holes up to 65 mm walls in accordance with DIN problem free installation Dry and dust-free assembly, Fire protection plug For provision of a round Packaging comprises 20 pieces BDS S90 bulkhead in ceilings and For bore holes up to 78 mm walls in accordance with DIN problem free installation Dry and dust-free assembly, Fire protection plug For provision of a round Packaging comprises 20 pieces BDS S90 bulkhead in ceilings and For bore holes up to 108 mm walls in accordance with DIN problem free installation dry and dust-free assembly, Fire protection plug For provision of a round Packaging comprises 20 pieces BDS S90 bulkhead in ceilings and For bore holes up to 123 mm walls in accordance with DIN problem free installation Dry and dust-free assembly, Fire protection plug For provision of a round Packaging comprises 20 pieces BDS S90 bulkhead in ceilings and For bore holes up to 135 mm walls in accordance with DIN problem free installation Dry and dust-free assembly, Fire protection plug For provision of a round Packaging comprises 20 pieces BDS S90 bulkhead in ceilings and For bore holes up to 165 mm walls in accordance with DIN problem free installation Dry and dust-free assembly, Fire protection plug For provision of a round Packaging comprises 20 pieces BDS S90 bulkhead in ceilings and For bore holes up to 200 mm walls in accordance with DIN problem free installation Dry and dust-free assembly, Fire protection block For closing gaps Set consists of 12 cartridges BDS-N (1K) and spandrels and at 310 ml each, white wall soffits Identification sign For permanent identification Set consists of 10 Fire protection plug of a cable bulkhead Identification signs Fire protection brick in accordance with DIN

108 Cable joint E30/E90 Cable joint E30-E90 Application Goods supplied Construction Assembly For connection of two pyrofil Keram cable types (N)HXH/(N)HXH CL/(N)HXCH FE180/E30-E60, (N)HXH/(N)HXCH FE180/E90. The cable joint provides the relevant circuit integrity of the cables. Full shrink tube, without squeeze connections. The joint consist of several heat-absorbing inner joints (depending on the number of conductor connections), an external joint and several insulating tubes that act as a flame barrier. Cables are prepared as usual, with offset connection order. The connection joint is installed using any common warm air device. Detailed assembly instructions are provided with each joint. Mandrel crimping is not permitted for crimped connections. For Datwyler pyrofil Keram types (N)HXCH with concentric conductor Article No. dimensions description from 1,5 mm 2 up to 4 mm 2 joint SMH from 6 mm 2 up to 10 mm 2 joint SMH from 16 mm 2 up to 25 mm 2 joint SMH from 35 mm 2 up to 50 mm 2 joint SMH from 70 mm 2 up to 95 mm 2 joint SMH from 120 mm 2 up to 150 mm 2 joint SMH from 185 mm 2 up to 240 mm 2 joint SMH4 For Datwyler pyrofil Keram types (N)HXH-O 4-conductor- or NHXH-J 5-conductor cables from 1,5/1,5 mm 2 up to 4/4 mm 2 joint SMHC from 6/6 mm 2 up to 10/10 mm 2 joint SMHC from 16/16 mm 2 up to 25/16 mm 2 joint SMHC from 35/16 mm 2 up to 50/25 mm 2 joint SMHC from 70/35 mm 2 up to 95/50 mm 2 joint SMHC from 120/70 mm 2 up to 150/70 mm 2 joint SMHC from 185/95 mm 2 up to 240/120 mm 2 joint SMHC4 106

109 Distribution box E30-E90 Type Hercules distribution box Hercules distribution box E30-E90 Hercules cover AHD E30-E90 Application Goods supplied Note Terminal box or cover for power current and low current in accordance with DIN to protect commercial distribution, branch boxes and sub-distribution boxes against the effects of fire for a period of 30 or 90 minutes (circuit integrity class E30 or E90), e.g. emergency lighting, alarm circuits and fire announcement systems, fire alarm systems, etc. Hercules cover box E30-E90 Typ AHD... incl. mounting angles, screws, cartridge of fire protection filler SP S 100 SM-K Hercules distribution box E30-E90 Typ HS... (Power current distribution box) incl. mounting screws, cartridge of fire protection filler S 100 SM-K top hat rail 35x7,5x250 mm. Hercules distribution box E30-E90 Typ HI... (Low current distribution box) incl. mounting screws, cartridge of fire protection filler S 100 SM-K QSA back mount frame... x 105 x 50 mm. (Quante: depth 30 mm, pitch: 27,5 mm) The Hercules distribution box or cover E30-E90 can be used for all pyrofil Keram cable types (N)HXH/(N)HXCH FE 180/E30-E60, (N)HXH/(N)HXCH FE 180/E90, JE-H(ST)H FE180/E30-E90/ JE-H(ST)HRH FE180/E30-E90. Function Installation Connections and branches of power current and low current. Please note that due to the selectivity of safety circuits or in the case of a decrease in cross section, a corresponding circuit breaker must be installed. The time required for assembly of the E30-E90 Hercules distribution box or cover is around 10 minutes. The screws are screwed into a predrilled hole without plugs. The cable inlets and outlets are sealed with the pyroplast S 100 SM-K fire protection filler. The cables do not not need to be tied. Article No. type outer dimensions (mm) Inner dimensions (mm) top hat rail / frame PU Hercules cover AHD E30-E AHD E x 380 x x 300 x 130 (empty without base) 1 pc. Hercules distribution box E30-E90 with top hat rail HS E x 380 x x 300 x x 7,5 1-row 1 pc HS E x 380 x x 300 x x 7,5 2-rows 1 pc HS E x 380 x x 300 x x 7,5, 3-rows 1 pc. Hercules distribution box E30-E90 with QSA trough HI E x 380 x x 300 x x 105 x 50 (6 strips) 1 pc HI E x 380 x x 300 x x 105 x 50 (11 strips) 1 pc HI E x 380 x x 300 x x 105 x 50 (13 strips) 1 pc. 107

110 Connection / terminal box E30-E90 Fuse element for VAD 2 VAD E30 - E90 Application Goods supplied Technical Data Technical Data Connection / terminal box. Tested on the basis of DIN , circuit integrity class E30. Halogen-free plastic box, cable glands, ceramic clamps, mounting rail and fire protection plugs. Material Halogen-free special compound, fail-safe Colour Orange Protection class IP 54 Fuse element for VAD 2 AC 230V fuse holder 5 x 20 mm with 2A fuse. Connection / terminal box VAD E30 E90 Article No. type outer dimensions (mm) Dimensions for branches up to PU VAD 2 5x6 E30-E x 100 x 50 5 x 0,5-6 mm 2 1,5 mm 2 1 pc VAD 2 3x10 E30-E x 100 x 50 3 x 1,5-10 mm 2 4 mm 2 1 pc VAD 2 8x6 E30-E x 165 x 76 8 x 0,5-6 mm 2 1,5 mm 2 1 pc. Article No. description/accessorie dimensions (mm) pu L x W x H AC 230V-Fuseholder 5 x 20 mm 40 x 20 x 20 1 pc. 108

111 Distribution box E30 AD E30 Application Goods supplied Technical Data Branch, connection or terminal box. Tested on the basis of DIN , circuit integrity class E30. Distribution box for emergency lighting or alarm systems. Connection box e.g. for smoke and heat extraction systems in damp areas (underground car parks, industry, etc.) Box and mounting rail for feedthrough terminals. Cable glands on request. Material Halogen-free, fire resistant special compound Systems test In accordance with DIN , circuit integrity class E30 Wiring assembly On customers request Cable inlets Available in various configurations Colour Orange Protection class IP 54 Distribution box AD E30 Article No. type outer dimensions (mm) dimensions pu on request AD E x 130 x mm 2 1 pc. on request AD E x 160 x mm 2 1 pc. on request AD E x 200 x mm 2 1 pc. on request AD E x 400 x 108 (twin-box, 6 inlets) mm 2 1 pc. 109

112 Emergency lighting BNL Emergency lighting/ escape route signage Application Technical Data Goods supplied Installation Combined emergency lighting/escape route signage for road tunnels. pyrofil safety cables with circuit integrity E90 are recommended for power supply. Housing made of V4A steel, material quality Available in surface or flush-mounting versions Protection class IP65 Safety glass front cover Quick-release fasteners Silicone sealing Stainless cable inlets, 15 mm diameter Escape route signage: Light source 2 x 11 Watt TC-L Emergency lighting: 150 Watt halogen lamp type R7S with asymmetrical reflector Combined emergency lighting/escape route signage including fastening devices. Surface or flush-mounting Article No. type dimensions pu (WxHxD) mm on request BNL / surface 560 x 400 x pc on request BNL / flush-mounting 560 x 400 x pc Please also take a look at our further tunnel accessories: Tunnel distribution box and tunnel clamp 110

113 E0 multi-cable support For wall and ceiling installations in accordance with MLAR 11/ Application Goods supplied Technical Data For fire-safe installation of multiple cables or lines along ceilings or walls above fireproof ceilings in accordance with MLAR 11/2005 (not for functional integrity!). Excerpt from MLAR 11/ : The special requirements pertaining to fireproof fasteners for lines installed in the area between floor slabs and suspended ceilings must be observed. Set consists of multi cable supports E0 and fire protection plugs KDM, 30 mm. Drill bit and tool set supplied separately. Recommended drill bit SDS1, recommended tool set SWM-SM 50. Material Sendzimir galvanised steel E0 E0S Inner dimensions approx 80 x 45 x 33 mm approx 55 x 35 x 33 mm Outer dimensions approx 87 x 60 x 33 mm approx 63 x 45 x 33 mm Cable load Installation spacing cm Cable weight 6,0 4,5 3,6 3,0 2,6 2,3 kg/m E0 multi-cable support Article No. type inner dimensions (mm) outer dimensions (mm) pu E0 multi-cable support approx 80 x 45 x 33 approx 87 x 60 x pcs E0 S multi-cable support approx 55 x 35 x 33 approx 63 x 45 x pcs. To speed up installation times for the E0 multi-cable support, we recommend using the Datwyler SWM-SM 50 setting tool. 111

114 Fire protection plugs K 6x5 30mm seat depth KDM 30mm seat depth KMu F10/KMu F12 40mm or 60mm seat depth Application Note For installation of cable systems with integrated circuit integrity. The fire protection plugs are suitable for applications in concrete. In order to guarantee the specified strength of the fire protection plugs, ensure that the drill holes are at the specified depth. When using the drill bit supplied with the plug set, the hole depth is maintained. Article No. plug mounting of Set/Info Plug set K6x5 SAS single clamps, Contains 200 K6x5 and SDS1 drill bit (required). 30 mm Single/distance clamps Recommended tool: set SM 6 SM with M6 thread Plug set KDM Single/distance clamps Contains 200 KDM and SDS1 drill bit (required). 30 mm with continuous hole mm, Recommended tool set: SWS-SM or SWS-SM 50. Hermann clamp Plug set KDM Shaped rails Contains 200 KDM andsds1 drill bit (required). 30 mm 2970/2 SLD Recommended tool set: SWS-SM (for laying strap clamps) Plugs KMuF10 Cable trays, cable ladders, Contains 50 KMuF10. M10 thread rod Required drill bit: SDS Duo-Set hv60 Recommended tool set: SMu10H Plugs KMuF12 Cable trays, cable ladders, Contains 50 KMuF12. M12 threaded rod Required drill bit: SDS Duo-Set hv60 Recommended tool set: SMu12H Plugs K6x80 Special mounting on insulated Contains 100 K6x80 for use with standard drill bit. ceilings or walls with insulation Min. required depth of 30mm to be guaranteed by the thickness up to 75mm depth gauge on the drilling machine. Recommended tool set: EWA 6x5 SM Plugs K6x105 Special mounting on insulated Contains 100 K6x110 for use with standard drill bit. ceilings or walls with insulation Min. required depth of 30mm to be guaranteed by the thickness up to 105mm depth gauge on the drilling machine. Recommended tool set: EWA 6x5 SM Plugs KMu LF8 tread rod M8 Contains 100 KMu LF8 112

115 Fire protection plugs SDS Duo-Set consisting of: SWM-SM SWS-SM 50 SMu 6 SM SDS 1 32 mm SDS 2 42 mm 1. SDS Duo Adapter hv x Duo tapered drill bit 6mm 3. 1x knock-out wedge Application Advantages The special drill bit enables holes to be drilled to the required depth. Ensures required - hole depth - less working time - less drilling - longer lasting drill bits Article No. drill bit info SDS1 Required for plugs K6x5 and KDM SDS 2 Required for plugs KMu LF SDS Duo-Set hv60 Required for plugs KMuF10 and KMuF12 Article No. tool set info SWM-SM Recommended for plugs KDM (hammer drill) SMu10H Recommended for plugs KMuF SMu12H Recommended for plugs KMuF SMu 6 SM Required for preassembled clamp (hammer drill) SWM-SM 50 Recommended for Hermann clamp (hammer drill) 113

116 Fire protection screws Special plugs MMS-P 7,5/45 40mm seat depth MMS-St 6/60 40mm seat depth HMS 5/40 30mm seat depth Gas concrete plugs PBD M 6x10 Identification sign Application Note For installation of cable systems with integrated circuit integrity. The mounting screws are suitable for applications in lime-sand bricks and aerated lime-sand bricks, red bricks and concrete. The gas concrete plugs are suitable for gas concrete P3,3 or better. Article No. mounting screws mounting of info HMS 5/40 SAS single clamps, Package contains 200 mounting screws Simple/distancing clamps Bore hole outer diameter is 4 mm with M6 thread For assembly, a T-drive adapter 20 is needed HMS-St 6/60 SAS single clamps, Package contains 100 mounting screws Simple/distancing clamps Bore hole outer diameter is 6 mm with M6 thread For assembly, a wrench / nut SW 10 is needed MMS-P 7.5/45 Shaped rails Package contains 100 mounting screws 2970/2 SLD Bore hole outer diameter is 6mm (for laying strap clamps), For assembly, a T-drive adapter 40 is needed Hermann clamps Identification sign For permanent identification Set consists of 10 identification Cable system of a cable system signs in accordance with DIN Article No. Special plugs mounting of info PBD M 6x10 Simple/distancing clamps Package contains 25 gas concrete plug sets Shaped rails Recommended tool set EWP 6x10 Hermann clamps Cable trays PBD M 10x10 Heavy cable trays Package contains 25 gas concrete plug sets Recommended tool set EWP 10x10 Article No. tool set info EWP 6x10 Recommended for plugs PBD M 6x10. Driven by hammer EWP 6x10 SDS Recommended for plugs PBD M 6x10. Driven by hammer drill EWP 10x10 Recommended for plugs PBD M 10x10. Driven by hammer EWP 6x10 SDS Recommended for plugs PBD M 6x10. Driven by hammer drill 114

117 Plastic armoured conduit Halogen-free Plastic armoured conduit, type Kupa DN M Application Technical Data For laying single and multiple cables on ceilings or walls. Circuit integrity is achieved for pyrofil -Keram cable types (N)HXH/(N)HXH CL/(N)HXCH FE180/E30-E60, (N)HXH/(N)HXCH FE 180/E90, JE-H(St)H FE180/E30-E90 and JE-H(St)HRH FE 180/E30-E90. Maximum permissible fixing distance: 800mm. Material Halogen-free plastic, flame retardant, corrosion resistant Colour Grey RAL 7035 Approvals VDE 0605; DIN EN ; DIN EN Classification 3 = Compressive strength medium (750N/5cm) 3 = Impact strength medium (2kg/100m) 4 = min. temperature - 25 C 2 = max. temperature + 90 C Halogen-free smooth plastic tube with molded sleeve on one end, in lengths of 3m. Article No. tube type I inner ø [mm] outer ø [mm] pu Fire load kwh/m Kupa DN 16 M 13,0 16,0 111 m 0, Kupa DN 20 M 16,8 20,0 111 m 0, Kupa DN 25 M 21,5 25,0 57 m 1, Kupa DN 32 M 28,0 32,0 57 m 1, Kupa DN 40 M 35,5 40,0 21 m 2, Kupa DN 50 M 45,2 50,0 21 m 2, Kupa DN 63 M 57,8 63,0 21 m 3,542 In order to attach Kupa plastic armoured conduits, we recommend SAS single clamps with fire protection plugs K6x5, 30mm, or strap clamps type B with C-shaped rail SLD and fire protection plugs KDM 30mm. Please also see our optional installation methods: Installation of cable bundles in clamps, installation in steel armoured conduits, etc. 115

118 Plastic armoured conduit Halogen-free / Bend, type Kupa DN MB Insertable sleeve, type Kupa DN MM Halogen-free plastic insertable sleeve Article No. Sleeve pu Kupa DN 16 MM 25 pcs Kupa DN 20 MM 50 pcs Kupa DN 25 MM 50 pcs Kupa DN 32 MM 25 pcs Kupa DN 40 MM 25 pcs Kupa DN 50 MM 10 pcs Kupa DN 63 MM 5 pcs. Halogen-free plastic insertable 90 bend Article No. bend pu Kupa DN 16 MB 25 pcs Kupa DN 20 MB 25 pcs Kupa DN 25 MB 25 pcs Kupa DN 32 MB 25 pcs Kupa DN 40 MB 25 pcs Kupa DN 50 MB 10 pcs Kupa DN 63 MB 5 pcs. Single clamp for plastic armoured conduit Article No. clamp type Kupa tube PG / Ø[mm] PU SAS 16 D DN pcs SAS 20 D DN pcs SAS 26 D DN pcs SAS 38 D DN pcs SAS 47 D new DN pcs SAS 55 D new DN pcs. In order to attach Kupa plastic armoured conduits, we recommend SAS single clamps with fire protection plugs K6x5, 30mm, or strap clamps type B with C-shaped rail SLD and fire protection plugs KDM 30mm. Please also see our optional installation methods: Installation of cable bundles in clamps, installation in steel armoured conduits, etc. 116

119 Steel armoured conduit Galvanised Steel armoured conduit, type Stapa DN SV Application Technical Data For laying single and multiple cables on ceilings or walls. Circuit integrity E30 is achieved for pyrofil -Keram cable types (N)HXH/(N)HXH CL FE180/E30-E60, JE-H(St)H FE180/E30-E90 und JE-H(St)HRH FE 180/E30-E90. Maximum permissible fixing distance: 800mm. Material Rolled ingot steel Colour Hot-dip galvanised, inside and outside, in accordance with EN/ISO 1461 Approvals VDE 0605; DIN EN ; DIN EN Classification 4 = Compressive strength heavy (1250N/5cm) 4 = Impact strength heavy (2kg/300m) 5 = min. temperature - 45 C 7 = max. temperature C Steel armoured conduit, round, hot-dip galvanised, in lengths of 3m Article No. tube type I inner Ø [mm] outer Ø [mm] pu Stapa DN 16 SV 13,3 16,0 30 m Stapa DN 20 SV 17,3 20,0 30 m Stapa DN 25 SV 22,1 25,0 30 m Stapa DN 32 SV 29,0 32,0 21 m Stapa DN 40 SV 37,0 40,0 15 m Stapa DN 50 SV 47,0 50,0 15 m Stapa DN 63 SV 59,5 63,0 15 m Insertable sleeve, hot-dip galvanised Article No. insertable sleeve pu Stapa DN 16 SVM 25 pcs Stapa DN 20 SVM 50 pcs Stapa DN 25 SVM 50 pcs Stapa DN 32 SVM 50 pcs Stapa DN 40 SVM 25 pcs Stapa DN 50 SVM 10 pcs Stapa DN 63 SVM 5 pcs. In order to attach Stapa steel armoured conduits, we recommend SAS single clamps with fire protection plugs K6x5, 30mm, or strap clamps type B with C-shaped rail SLD and fire protection plugs KDM 30mm. Please also see our optional installation methods: Installation of cable bundles in clamps, installation in plastic armoured conduits, etc. 117

120 Steel armoured conduit Galvanised / Galvanised steel armoured conduit Bend, type Stapa DN SVB Insertable sleeve, type Stapa DN SVM End part, type Stapa DN SVE Insertable 90 bend, galvanised Article No. bend pu Stapa DN 16 SVB 15 pcs Stapa DN 20 SVB 25 pcs Stapa DN 25 SVB 25 pcs Stapa DN 32 SVB 20 pcs Stapa DN 40 SVB 15 pcs Stapa DN 50 SVB 5 pcs Stapa DN 63 SVB 3 pcs. End part, galvanised Halogen-free end part, full plastic Article No. end part pu article No. end part pu Stapa DN 16 SVE 25 pcs Stapa DN 16 SKE 50 pcs Stapa DN 20 SVE 50 pcs Stapa DN 20 SKE 100 pcs Stapa DN 25 SVE 50 pcs Stapa DN 25 SKE 100 pcs Stapa DN 32 SVE 50 pcs Stapa DN 32 SKE 50 pcs Stapa DN 40 SVE 25 pcs Stapa DN 40 SKE 50 pcs Stapa DN 50 SVE 10 pcs Stapa DN 50 SKE 25 pcs Stapa DN 63 SVE 5 pcs Stapa DN 63 SKE 20 pcs. Single clamp for steel armoured conduit Article No. clamp type Stapa conduit PG / Ø[mm] pu SAS 16 D DN pcs SAS 20 D DN pcs SAS 26 D DN pcs SAS 38 D DN pcs SAS 47 D new DN pcs SAS 55 D new DN pcs. In order to attach Stapa steel armoured tubes, we recommend SAS single clamps with fire protection plugs K6x5, 30mm, or strap clamps type B with C-shaped rail SLD and fire protection plugs KDM 30mm. Please also see our optional installation methods: Installation of cable bundles in clamps, installation in plastic armoured conduits, etc. 118

121 Steel armoured conduit Black varnished Steel armoured conduit, type Stapa DN SL Application Technical Data For laying single and multiple cables on ceilings or walls. Circuit integrity E30 is achieved for pyrofil -Keram cable types (N)HXH/(N)HXH CL/ FE180/E30-E60, JE-H(St)H FE180/E30-E90 and JE-H(St)HRH FE 180/E30-E90. Maximum permissible fixing distance: 800mm. Material Rolled ingot steel Colour Stove-enamel based on alkyd melamin resin, free of heavy metals, black Approvals VDE 0605; DIN EN ; DIN EN Classification 4 = Compressive strength heavy (1250N/5cm) 4 = Impact strength heavy (2kg/300m) 5 = min. emperature - 45 C 6 = max. temperature C Steel armoured conduit, round, black varnished, in lengths of 3m Article No. tube type I inner ø [mm] outer ø [mm] Stapa DN 16 SL 13,3 16,0 30 m Stapa DN 20 SL 17,3 20,0 30 m Stapa DN 25 SL 22,1 25,0 30 m Stapa DN 32 SL 29,0 32,0 21 m Stapa DN 40 SL 37,0 40,0 15 m Stapa DN 50 SL 47,0 50,0 15 m Stapa DN 63 SL 59,9 63,0 15 m Insertable sleeve, black varnished Article No. insertable sleeve pu Stapa DN 16 SLM 25 pcs Stapa DN 20 SLM 50 pcs Stapa DN 25 SLM 50 pcs Stapa DN 32 SLM 50 pcs Stapa DN 40 SLM 25 pcs Stapa DN 50 SLM 10 pcs Stapa DN 63 SLM 5 pcs. In order to attach Datwyler Stapa steel armoured conduits, we recommend SAS single clamps with fire protection plugs K6x5, 30mm, or strap clamps type B with C-shaped rail SLD and fire protection plugs KDM 30mm. Please also see our optional installation methods: Installation of cable bundles in clamps, installation in plastic armoured conduits, etc. 119

122 Steel armoured conduit Black varnished / Steel armoured conduit black varnished Bend, type Stapa DN SLB Insertable sleeve, type Stapa DN SLM End part, type Stapa DN SLE Insertable 90 bend, black varnished Article No. bend pu Stapa DN 16 SLB 15 pcs Stapa DN 20 SLB 25 pcs Stapa DN 25 SLB 25 pcs Stapa DN 32 SLB 20 pcs Stapa DN 40 SLB 15 pcs Stapa DN 50 SLB 5 pcs Stapa DN 63 SLB 3 pcs. End part, black varnished Halogen-free end part, full plastic Article No. end part pu article No. end part pu Stapa DN 16 SLE 25 pcs Stapa DN 16 SKE 50 pcs Stapa DN 20 SLE 50 pcs Stapa DN 20 SKE 100 pcs Stapa DN 25 SLE 50 pcs Stapa DN 25 SKE 100 pcs Stapa DN 32 SLE 50 pcs Stapa DN 32 SKE 50 pcs Stapa DN 40 SLE 25 pcs Stapa DN 40 SKE 50 pcs Stapa DN 50 SLE 10 pcs Stapa DN 50 SKE 25 pcs Stapa DN 63 SLE 5 pcs Stapa DN 63 SKE 20 pcs. Single clamp for steel armoured conduit Article No. clamp type Stapa conduit PG / Ø[mm] pu SAS 16 D DN pcs SAS 20 D DN pcs SAS 26 D DN pcs SAS 38 D DN pcs SAS 47 D new DN pcs SAS 55 D new DN pcs. In order to attach Datwyler Stapa steel armoured tubes, we recommend SAS single clamps with fire protection plugs K6x5, 30mm, or strap clamps type B with C-shaped rail SLD and fire protection plugs KDM 30mm. Please also see our optional installation methods: Installation of cable bundles in clamps, installation in plastic armoured conduits, etc. 120

123 Colour codes in accordance with VDE, CENELEC and SEV standards Core colours in accordance with DIN VDE : 01/2003 (CENELEC HD /2001) No. of cores 1(-O) 1(-J) 2(-O) 2(-J) 3(-O) 3(-J ) 3 a (-O) 4(-O) 4(-J ) 4 a (-J) 5(-O) 5(-J) Function of core L N PE LN LPE 3L LNPE 2LN 3LN 3LPE 2LNPE 4LN 3LNPE Yellow-green (PE) Blue (N) Brown (L) Black (L) Grey (L) L = Phase conductor Colour code for cables 6 cores (a only for certain applications) N = Neutral conductor Phase conductor = Black with white number printing PE = Protective conductor Protective conductor = Green-yellow Cable printing In order to guarantee the retraceability, all pyrofil cables are identified with the production batch. The meter marking simplyfies the cable handling. Printing example Core colours in accordance with VDE 0815 for fire alarm cables JE-H(ST)H...Bd Ring group 1 Ring group 2 Ring group 3 Ring group 4 DATWYLER PYROFIL KERAM FE180 «N x MM2» SWISS MADE «PRODUCTION BATCH» «METER MARKS» 1. Two pairs 2. Three pairs and more Pair 1: a-core blue, b-core red Pair 1: a-core blue, b-core red Pair 2: a-core grey, b-core yellow Pair 2: a-core grey, b-core yellow Remark: Only two pair cable is a Quad Pair 3: a-core green, b-core brown Pair 4: a-core white, b-core black Pair Core a Core b Each bundle is part of a ring group. All cores of a bundle are identified by the ring colour or by a plastic helix with printed numbers. Counting to be started at inside layer. Identification of bundles Ring group consist. of Bundle no Ring colour Helix 4 cores I I II II 8 cores resp. I II III IV I II III IV I II III IV I II III IV I II III IV 4 pair Core colours of wiring cables J-H(ST)H...Bd Circuit 1 Circuit 2 Basic colours of insulation of the 5 star quads of a bundle 1. Quad: Basic colour of all cores red 4. Quad: Basic colour of all cores yellow 2. Quad: Basic colour of all cores green 5. Quad: Basic colour of all cores white 3. Quad: Basic colour of all cores grey The cores of a quad are identified by rings a-core b-core a-core b-core The bundle where counting has to be started is identified by a red plastic tape. Remaining bundles are identified by white or neutral tapes. 121

124 E30-E90 support systems Preventive fire protection and circuit integrity The co-ordinated and licensed Datwyler products enable optimal system approaches and guarantee quality, cost-efficiency, saving of time and security. 300 mm Standard laying technics with single clamp (of different manufacturers) 600 mm Standard laying technics with strap clamp with trough (of different manufacturers) 00 / 800 mm Hermann clamp: bundling e.g. 30 cables 3x1,5mm 2 00 / 800 / 1200 mm Single clamp:,5 kg/m Strap clamp:,5 kg/m also with cable conduit with thread rod suspension 10Kg 1200 mm Standard cable tray (of different manufactures) Datwyler E30-E90 Support systems 30Kg with/without thread rod suspension 1500 mm Datwyler cable tray without thread rod suspension for wall and ceiling installation. Optional laying techniques with different cable tray manufacturers. 122

125 iec international Electrotechnical Commision IEC IEC IEC IEC Conductors of insulated cables Tests for electric cables under fire conditions - Circuit integrity - Part 1: Test method for fire with shock at a temperature of at least 830 C for cables of rated voltage up to and including 0,6/1,0 kv and with an overall diameter exceeding 20 mm Tests for electric cables under fire conditions - Circuit integrity - Part 11: Apparatus - Fire alone at a flame temperature of at least 750 C Tests for electric cables under fire conditions - Circuit integrity - Part 2: Test method for fire with shock at a temperature of at least 830 C for cables of rated voltage up to and including 0,6/1,0 kv and with an overall diameter not exceeding 20 mm IEC Tests for electric cables under fire conditions - Circuit integrity - Part 21: Procedures and requirements - Cables of rated voltage up to and including 0,6/1,0 kv IEC Tests for electric cables under fire conditions - Circuit integrity - Part 23: Procedures and requirements - Electric data cables IEC Tests for electric cables under fire conditions - Circuit integrity - Part 25: Procedures and requirements - Optical fibre cables IEC Test on electric and optical fibre cables under fire conditions. Part 1-1 Test for vertical flame propagation for a single insulated wire or cable - Apparatus IEC Test on electric and optical fibre cables under fire conditions. Part 1-2 Test for vertical flame propagation for a single insulated wire or cable Procedure for 1 kw pre-mixed flame IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC en Tests on electric cables under fire conditions - Part 3-10: Test for vertical flame spread of vertically-mounted bunched wires or cables - Apparatus Tests on electric and optical fibre cables under fire conditions Part 3-22: Test for vertical flame spread of vertically-mounted bunched wires or cables Category A Tests on electric and optical fibre cables under fire conditions - Part 3-23: Test for vertical flame spread of vertically-mounted bunched wires or cables - Category B Tests on electric and optical fibre cables under fire conditions - Part 3-24: Test for vertical flame spread of vertically-mounted bunched wires or cables - Category C Tests on electric and optical fibre cables under fire conditions - Part 3-25: Test for vertical flame spread of vertically-mounted bunched wires or cables - Category D Test on gases evolved during combustion of materials from cables - Part 1: Determination of the amount of halogen acid gas Test on gases evolved during combustion of electric cables - Part 2: Determination of degree of acidity of gases evolved during the combustion of materials taken from electric cables by measuring ph and conductivity Optical fibre cables - Part 1-2: Generic specification - Basic optical cable test procedures Measurement of smoke density of cables burning under defined conditions - Part 1: Test apparatus Measurement of smoke density of cables burning under defined conditions - Part 2: Test procedure and requirements european Norm EN EN EN EN EN EN EN EN EN EN EN EN Method of test for resistance to fire of unprotected small cables for use in emergency circuits Common test methods for cables under fire conditions. Tests on gases evolved during combustion of materials from cables. Apparatus Common test methods for cables under fire conditions. Tests on gases evolved during combustion of materials from cables. Procedures. Determination of the amount of halogen acid gas Common Test Methods for Cables Under Fire Conditions - Tests on Gases Evolved During Combustion of Materials From Cables - Part 2-2: Procedures - Determination of Degree of Acidity of Gases for Materials by Measuring ph and Conductivity Common test methods for cables under fire conditions. Tests on gases evolved during combustion of materials from cables. Procedures. Determination of degree of acidity of gases for cables by determination of the weighted average of ph and conductivity Method of test for resistance to fire of larger unprotected power and control cables for use in emergency circuits Insulating, sheathing and covering materials for low voltage energy cables - Part 5: Halogen-free, cross-linked insulating compounds Conductors of insulated cables Tests on electric and optical fibre cables under fire conditions - Part 1-1: Test for vertical flame propagation for a single insulated wire or cable - Apparatus Tests on electric and optical fibre cables under fire conditions - Part 1-2: Test for vertical flame propagation for a single insulated wire or cable - Procedure for 1 kw pre-mixed flame Measurement of smoke density of cables burning under defined conditions. Test apparatus Measurement of smoke density of cables burning under defined conditions. Test procedure and requirements 123

126 vde verband der Elektroingenieure VDE VDE VDE VDE VDE VDE Testing of cables, wires and flexible cords; continuance of isolation effect under fire conditions Method of test for resistance to fire of unprotected small cables for use in emergency circuits Common test methods for cables under fire conditions - Tests on gases evolved during combustion of materials from cables - Part 1: Apparatus Common test methods for cables under fire conditions - Tests on gases evolved during combustion of material from cables - Part 2-1: Procedures; determination of the amount of halogen acid gas; German version EN :1998 Common test methods for cables under fire conditions - Tests on gases evolved during combustion of material from cables - Part 2-2: Procedures; determination of degree of acidity of gases for materials by measuring ph and conductivity Common test methods for cables under fire conditions - Tests on gases evolved during combustion of material from cables - Part 2-3: Procedures; determination of degree of acidity of gases for cables by determination of the weighted average of ph and conductivity VDE Test on electric and optical fibre cables under fire conditions. Part 1-1 Test for vertical flame propagation for a single insulated wire or cable - Apparatus VDE Test on electric and optical fibre cables under fire conditions. Part 1-2 VDE VDE VDE din DIN BS BS A2 BS 6387 BS BS BS EN BS A2 Test for vertical flame propagation for a single insulated wire or cable Procedure for 1 kw pre-mixed flame Method of test for resistance to fire of larger unprotected power and control cables for use in emergency circuits Measurement of smoke density of cables burning under defined conditions - Part 1: Test apparatus Measurement of smoke density of cables burning under defined conditions - Part 2: Test procedure and requirements deutsche Industrie Norm Fire behaviour of building materials and building components - Part 12: Circuit integrity maintenance of electric cable systems; requirements and testing british Standard Fire detection and fire alarm systems for buildings. Code of practice for system design, installation, commissioning and maintenance Specification for performance requirements for cables required to maintain circuit integrity under fire conditions Electric cables. Specification for 300/500 V fire resistant screened cables having low emission of smoke and corrosive gases when affected by fire. Multicore and multipair cables Specification for insulating and sheathing materials for cables. General introduction Conductors of insulated cables Test for unprotected small cable for use in emergency circuits BS EN with a 930 C flame and with water spray VdS verein deutscher Sachversicherer VdS 3423 E90 Kabel für Wasser-Löschanlagen mit zusätzlichem Funktionserhalt bei Einwirkung von Wasser, Anforderungen und Prüfmethoden (Entwurf ) nbn belgian Norm NBN Fire fighting - Fire performance of building materials and products - Fire resistance of building materials 124

127 infrastructure management capacity management energy management asset management building, technology, network management resource documentation & visualisation documentation of all objects numeric graphical topological planning & controlling process workflow generation budgeting work orders analysing & managing troubleshooting escalation management resource optimisation analysis, reports, queries active risk management remote monitoring remote controlling service and maintenance automisation Panorama Management Software Solution Support of universal building, technology and network management Datwyler 125

128 Panorama Customised solutions Optimal planning by comprehensive function modules Panorama a Datwyler solution functions Infrastructure mapping complete documentation of all recorded objects infrastructure visualisation and management Planning by workflows overview from initial layout to roll-out set-up of processes by ITIL coordination of resources assignment of activities/tasks Panorama is an universal management software, optimised for networks, technologies and buildings. The software can be deployed in many industries such as telecommunications, electrical engineering and finance. objects cockpit sites buildings technologies networks realtime monitoring of all current values processes resources control centre Panorama supports the documentation of all objects to be recorded and the visualisation of all processes and workflows to manage these objects including any generation of activities and assignment of tasks around the service and maintenance management as well as fault and alarm management. Individual solutions by deploying Panorama functional modules Sites graphic and alphanumerical site management visualisation of imported CAD, GIS and Google Earth data area management information such as utilisation, energy consumption and cost data calculation and evaluation of site data Buildings technical and commercial building management visualisation of imported CAD, GIS and Google Earth data facility management information such as heating systems, cabling infrastructures, climate and access control calculation of lease/additional costs visualisation of consumption data maintenance and service management by processes and workflows 126 Datwyler

129 Panorama Customised solutions Technologies facilities and devices visualisation and documentation device/array layout, configuration and operation via remote monitoring and remote control reports support fault management, deficiency analysis and asset management Networks management and visualisation, from cable trays up to single optical fibre illustration of infrastructure including all logical connections workflow and task instructions for patch panel moves, adds, changes Processes, workflows processes and workflows for layout, installation and roll-out: support of maintenance and service intervals, fault and alarm management, IT Infrastructure Library (ITIL), et cetera Resources coordination of staff, tools, equipment, machinery planning of maintenance and service activities free definition of resources and intervals Control centre control centre function for building control, transportation and energy systems, production lines and further applications remote monitoring and remote control enable control of heterogeneous technologies visualisation and monitoring of technical processes (Supervisory Control and Data Acquisition, SCADA) Fault management and alarm systems incoming alarms ordered by priorities individually defined workflows enable to send s, to create pop-up screens and to start assignments of tasks and processes Development of individual solutions for technical and commercial building management Some examples are: collection of metering data connection to facility management system benchmarking calculation and billing Project approach to implement Panorama Datwyler services Analysis Design Implementation Roll-Out Datwyler takes responsibility for all necessary services: needs/requirements feasibility concept user requirement specifications technical specifications statement of work interface definitions Statement of work software adaptation interface adjustment system check roll-out to user implementation of Panorama software operation of Panorama software management of physical infrastructure based on an SLA User requirement specifications Acceptance procedure Going live Optional Datwyler support economic efficiency calculation project management, quality management training, documentation user support, maintenance, hosting Datwyler 127

130 System solutions from a single source ICT Networks Leading know-how As a provider of total solutions for information and telecommunication networks, Datwyler possesses extensive know-how accumulated over decades: - Almost 100 years of experience in cable production. - Leading material, production and process know-how in the fabrication of copper and fibre-optic cables and components. - Solid electro-technical competency. - Close collaboration with renowned technical universities, international standards committees, and independent testing institutes. - Broad systems competence. Diverse applications In the field of ICT networks Datwyler concentrates on communication infrastructures for public and commercial buildings and for FTTx networks. Some examples are: - Office, industrial and exposition buildings - Data centres - Hotels and hospitals - Stadiums, theatres, concert halls - Airports and train stations - FTTx projects of public utility companies and energy supply companies In these market segments we can also flexibly meet individual customer requirements up to and including turnkey and multi-site projects with our cost-effective, modular system solutions and compehensive services. 128 Datwyler

131 Complete system solutions - Screened and unscreened copper system solutions (categories 3 to 7A) for the transmission of voice, data, video, CATV, control signals and remote power (power over Ethernet, PoE). - Innovative fibre-optic system solutions with single-mode and multimode optical fibres for indoor and outdoor applications, from LAN backbones to FTTH in-house cabling. - Software solution for building, technology and network management. - Extensive services ranging from consulting and planning via pre-fabrication, logistics and installation to system maintenance. - Established worldwide, actively managed and certificated partner network. - Rigorous training and certification programme to guarantee optimal installation quality of our systems and solutions year warranty covering the entire system. Yangshan Deepwater Port administration centre, Shanghai Selected reference projects Airrail Center Frankfurt a.m. Crane House South Cologne Party school campus Hangzhou Dubai Motor City Dubai Kunming Airport Kunming Swisscom IT Services Zollikofen UBI Banca (1964 branch offices) Bergamo UBS central administration, Flurhof Zurich Swiss parliament building Berne Allianz Arena Munich Dexia BIL Luxembourg KPMG German headquarters Berlin Focus on customer value Datwyler stands for more than just the fabrication and distribution of products. For your ICT networks we offer future-proof, modular, customised one-source solutions for all your specific applications as a uniquely attractive overall package, with all the necessary test certificates, authorizations and certificates and with long-term warranties. The interaction of these elements creates added value. As a customer you benefit from maximum network availability and high investment protection, even with regard to future applications, expansions and changes. Allianz Arena, Munich Datwyler 129

132 Product Overview Integrated, future-proof cabling solutions for ultimate reliability in voice, data, video and CATV applications More than just products With the complete packages offered by Datwyler you are opting for comprehensive application-neutral and provider-independent system solutions encompassing the communication infrastructure for office and industry environments and for FTTx projects. For Datwyler quality testing and quality management begin during the cable production process. Here relevant electrical and mechanical data are recorded online and automatically compared with the predefined specifications. Mostly these specifications considerably exceed current standards and drafts. Faceplate for PS-TERA TM module Patch cords PS-TERA TM /RJ45 Module PS-TERA TM 1/8 Cat.7 Patch panel MPS 12x, 16x, 24x, 32x for MS 1/8 or PS-TERA TM modules Datwyler follows the same procedure for the production of connection components, e.g. data outlets, patch panels and patch cables for copper and fibre-optic systems. Marking of individual components ensures that data measured up to the time of production can be called up at any point in the future. This gives users or investors a high degree of certainty that the products used and manufactured provide the durability demanded by them. Faceplate for MS-K Plus 1/8 modules RJ45 module MS-K Plus 1/8 Cat.6 A Industrial data outlet IP67 for MS 1/8 module Industrial REG adapter MS IP20 for MS 1/8 module Industrial patch cord PUR Copper patch cord Data outlets CSD Plus 2/8 K, CSD Plus 2/8 U Cat.6 A (IEC) Patch panel CSA 24/8 Plus Cat. 6 A 130 Datwyler

133 FO patch panel OV-A FO data outlet FO patch panel FO wall-mounted distribution box OV-W FO indoor cable uninet installation/ flexible cable FO in- and outdoor cable FO Safety outdoor cable e.g.: Cat.6 A : P Cat.7: P better than Cat.7 A : P Multimedia TV balun, active balun up to 862 MHz for the distribution of CATV signals Multimedia TV panel, active distributor field up to 862 MHz for the distribution of CATV signals Datwyler 131

134 Product Overview Copper Fibre optic Cables screened / unscreened Connection screened / unscreened Cables Connection uninet installation/ flexible cable Modules optofil indoor cable Fibre optic adapters and couplers Copper patch cords Patch panels optofil outdoor cable optofil Safety Fibre optic patch panels Multiple cable, highly flexible pre-assembled copper data cables Faceplates Fibre optic patchand adapter cable Fibre optic faceplates Multiple cable pre-assembled copper data cables Floor-box solutions Fibre optic multiple cable Fibre optic wall mounted distribution boxes Measurement cable Fibre optic multiple cable BreakOut system Are you looking for a building, technology and network management software which enables effective planning, management, documentation and control of all objects and processes around your infrastructure? Feel free to ask for details about Panorama! 132 Datwyler

135 High Density Wireless Active MHD Modular High Density cabling system Network/Server racks Wi-Fi Powerful Wireless Fidelity Multimedia and switching MHD housings Network rack Wi-Fi Arrays TV panel active distributor field up to 862 MHz for the distribution of CATV signals MHD copper distribution cartridges Server rack Transformers TV balun active balun up to 862 MHz for the distribution of CATV signals MHD multiple cable pre-assembled copper data cables Wall chassis Access points Network cameras MHD FO distribution cartridges Minirack Management system Video monitoring system MHD multiple cable pre-assembled FO data cables Switches Find our ICT network products and solutions in the respective catalogue. Datwyler 133

136 Maximum flexibility in installation Building Automation The modular product portfolio for optimised system integration System ECO-A flatform cable system System ECO-B products for the decentral, modular integration System ECO-C products for the central, clear integration System ECO-D products for the decentralised, fast integration System ECO-E products for simple, economic integration Modern office and administration buildings require future-proof, adaptable electrical systems. Users are no longer willing to be restricted by non-flexible solutions. They demand plug-andplay in the form of flexible control and automation of virtually every technical function of the building. With building automation solutions from Datwyler, many functions and systems such as HVAC, lighting, security and load management can be easily integrated. Control tasks can be done centrally, decentrally or automatically. System ECO-F products for flexible, efficient integration System ECO-M products for Smart Metering System ECO-S software System ECO-T SIP door communication 134 Datwyler

137 Leading know-how As a provider of total solutions for the electrical and communications infrastructure of public and commercial buildings, Datwyler possesses leading know-how acquired over decades. Applying our competence in materials, production and processing in the fabrication of flatform cables, we have developed the ECO-A system, a comprehensive solution combining flexible power distribution with control and automation of all building functions. Complete system solutions Decentral, modular and pluggable Datwyler offers sustainable system solutions tailored to changing customer needs, upcoming technologies and energy-efficient operation. Thus, our building automation solutions ensure high operational reliability and low operational costs. Sony Center, Berlin Selected reference projects MDR Erfurt Daimler Chrysler Stuttgart NBV UGA Herongen Frankfurt Stock Exchange Frankfurt Petronas Towers Kuala Lumpur Sony Center Berlin District hospital Winterswijk Diverse applications In recent years Datwyler has extended its proven ECO-A portfolio to include eight product groups for building automation based on the KNX standard. These product groups are used in system solutions for basic infrastructure as well as tenant improvements, including a wealth of applications such as responsive lighting, intelligent shading, HVAC, connections to third party systems, visualisation, power data metering and door communication via SIP. The product groups have a modular structure and can be deployed in any combination. This makes it possible to achieve a cost-effective solution for every project. Combined with our flatform cable systems for power distribution and data transmission and with our control and visualisation software which makes various systems available on one platform, the Datwyler product portfolio meets all requirements of intelligent building automation. Customer value in focus Datwyler stands for more than the production and distribution of high-quality products. For your technical building systems we provide modular total solutions from one source, including consulting, support, logistics, warranty and turnkey responsibility if required. Integrating these elements into sophisticated attractive overall packages creates added value. As a customer you benefit from: - drastically reduced cabling - the use of factory-ready modules - easier planning and documentation - reduced installation time - high flexibility, rapid changeability and adaptability - higher safety due to lower fire loads - cost-saving operation - lower power consumption - cost-effectiveness due to customised total solutions - long-term investment protection Datwyler 135

138 Product Overview System description Modern building services installation calls for control and automation of the widest possible range of functions. Whereas conventional electrical building services installation merely distributes power and could be switched if necessary, the ECO-A system meets the higher standards demanded of modern building services. Compared with conventional electrical installation, modern building management using a Datwyler buildung automation system features a minimum of cable expenditure, rapid adaptability, and flexible use of space. This guarantees that your investment will retain its value for decades to come. Our cabling solutions enables the problem-free linking of a very wide variety of building services functions and facilities that have been strictly separated to date such as heating, air conditioning, ventilation, lighting, building surveillance, and load management. Open and closed-loop control operations can be centralised or decentralised. The flatform cables and appropriate pre-assembled plug-in and screw components make insulation stripping unnecessary and considerably reduce installation time. The installations can be modified or extended without any major planning effort. The modular building automation product portfolio enables optimised system integration. The portfolio ranges from preconfigured plug-and-play solutions for decentralised systems, to cost-effective semi-centralised room solutions e.g. for hotels, hospitals and office buildings to total solutions for centralised building automation systems. System ECO-C products for the central, clear integration System ECO-E products for simple, economic integration Flatform cable Data with Data Adapter outgoing circuit without insulation stripping for inter-connecting the sensors with flatform data transmission cables Combi Adapter 5x2.5+2x0.5 combined data and power output circuit for flatform cables Combi Flatform cable Power 5x10 flatform power cable 5x10mm 2 e.g. for power supplies 136 Datwyler

139 Power I Adapter power in- and output Flatform cable Power I 7x2,5+5x16mm 2 for damp location, flatform power cable system for engine rooms and industrial applications Flatform cable Combi combined data and power flatform cable, e.g. for lighting supply and switching operations System ECO-D compact, plug-in KNX actuators with fast connection technology for error-free assembly in intermediate floors or suspended ceilings Flatform cable Patch pre-assembled patch cables to connect consumers and to supply office actuators System ECO-B products for the decentral, modular integration KNX IR Remote Control ECO-E ZN1IR Flatform cable Power 5x10 with Power 5x10 Adapter out power output circuit for flatform cable Power 5x10mm 2 e.g. pre-assembled with floor boxes and output circuit fuse KNX sensing device twofold, fourfold Flatform cable Data data cable Data-R round data cable Datwyler 137

140 Flatform cable systems and accessories (ECO-A) CablE In- and Output Output Flatform cable Combi PVC 5x2,5 mm 2 + 2x1,5 mm 2 Art.No FR/LSOH 5x2,5 mm 2 + 2x1,5 mm 2 Art.No Combi Adapter-S 5x Energy+Bus Art.No Combi Adapter-S 5x Energy Art.No Combi Adapter-S Bus Art.No Combi Adapter 3x Energy+Bus EIB/KNX Art.No Combi Adapter 3x Energy+Bus Art.No Combi Adapter 3x Energy Art.No Flatform cable Data PVC 2x1,5 mm 2 Art.No / FR/LSOH 2x1,5 mm 2 Art.No / Data Adapter EIB/KNX Art.No Data Adapter Art.No Data Adapter Quick Art.No Flatform cable Power 5x2,5 mm 2 PVC 5x2,5 mm 2 Art.No FR/LSOH 5x2,5 mm 2 Art.No Power Adapter-S 5x Energy Art.No Power Adapter 3x Energy Art.No Power Adapter 5x Energy Art.No Flatform cable Power 5x10 mm 2 PVC 5x10 mm 2 Art.No FR/LSOH 5x2,5 mm 2 Art.No Power 10 Adapter 5x Energy Art.No Power Adapter 5x Energy Art.No Flatform cable Power I 7x2,5 mm 2 IP67 PVC 7x2,5 mm 2 Art.No FR/LSOH 7x2,5 mm 2 Art.No Power I Adapter for screw-tightened connection 7x2,5 InOut Art.No Power I cable glands for Power I Adapter Ø 9-16 Art.No Ø Art.No Ø 11-20,5 Art.No Blind-gland Art.No Flatform cable Power I 5x16 mm 2 IP65 PVC 5x16 mm 2 Art.No FR/LSOH 5x16 mm 2 Art.No Power I Adapter for screw-tightened connection 5x16 InOut Art.No Power I cable glands for Power I Adapter Ø 9-16 Art.No Ø Art.No Ø 11-20,5 Art.No Ø Art.No Blind-gland Art.No Datwyler

141 Fixing device ending device Combi Adapter EIB/KNX 5x Energy+Bus EIB/KNX Art.No Combi Adapter 5x Energy+Bus Art.No Combi Adapter 5x Energy Art.No Uni Fix Art.No Fix Art.No Tape Art.No Combi Tool stripping tool Art.No Combi End Art.No Uni Fix Art.No / Combi Tool stripping tool Art.No Data End Art.No Fix Art.No Uni Fix Art.No / Tape Art.No Power End Art.No Fix Art.No Combi Tool stripping tool Art.No Power Fix Art.No Tape Art.No Power 10 End Art.No Power 10 Tool cable stripper Art.No Power I Adapter socket 7x2,5 Art.No Power I Plug IP67 Art.No Fix Art.No Tape Art.No Power I End 7x2,5 Power I Adapter 7x2,5 InOut Art.No Power I Adapter screw-tightened connection 5x16 Out for single and double branch connection up to 5x6mm 2 Art.No Power I Adapter screw-tightened connection 5x16 InOut Art.No Fix Art.No Tape Art.No Power I End 5x16 Art.No Datwyler 139

142 Building Automation Mounting and installation System ECO-B System ECO-C System ECO-D Products for the decentral, modular integration Products for the central, clear integration Products for the decentralised, fast integration Project-specific optimised installation box for mounting in false ceilings or raised floors. Use of pre-assembled patch cables to connect consumers and to supply the box. System devices, IP and DALI devices and multi-channel KNX sensors and actuators for centralised and decentralised installation in electrical distributors and in rooms. Compact, plug-in KNX actuators with fast connection technology for error-free assembly in intermediate floors or suspended ceilings. decentralised mounting project-specific configuration modular devices plug-in connections KNX Basic Module combined with up to 4 Sub-modules e.g.: Switching Actuator 4 x 16 A DALI Actuator 2 x 8-fold Dimmer 2 x 250 VA Blind Actuator 2-fold Binary Input 8-fold Semiconductor Switch 4-fold EnOcean Gateway 16-fold decentralised mounting flat size plug-in connections directly to the Combi cable Switching Actuator 4 x 16 A Switching Actuator 6 x 16 A Switching/ Dimming Actuator 2-fold Blind Actuator 2-fold Combi Actuator 1 x Switch + 2 x Blinds EnOcean Gateway 56-fold + 4 x 16 A centralised mounting for distribution boards KNX Power supply KNX/USB interface KNX/IP interface/router KNX/DALI Gateway Binary Input 8 to 16-fold Binary Output 8 to 16-fold Load Switch 8 to 12-fold Blind Actuator 4 to 8-fold decentralised mounting flush- or wall-mounting devices KNX push button interface 2-fold/4-fold KNX presence detector with constant light dimming KNX touch panel optional products and accessories EnOcean Aerial EnOcean Aerial 140 Datwyler

143 System ECO-E System ECO-F System ECO-M System ECO-T Products for simple, economic integration Products for flexible, efficient integration Products for Smart Metering Products for IP door communication Highly functional, but easy to-integrate KNX products with innovative features for central room functions. High-quality user interfaces with touchsensitive tactile zones and multitouch function. Standard push buttons sensors and EnOcean Wireless sensors. Meters for electrical energy with standardised communication interface, network coupler and versatile temperature sensors for different applications. SIP Module System and SIP Doorstations for door communication via IP network. Door Camera Steel SIP Door Module ECO and Maxi Push Button Modules SIP Door Station IP54 SIP Door Station IP54 Video KNX Power Supply Multi-functional Actuator 4 x 10 A Multi-functional Actuator 6 x 10 A 3-Phase Energy Meter Direct- and Transformerconnection Communication Interface e.g. KNX, M-Bus, Ethernet et al. Multi-functional Actuator 4 x 16 A KNX 3-Phase Energy Meter Universal Dimming Unit 400 VA KNX Network Interface KNX Touch Display KNX Sentido Interface KNX Room Temperature Sensor Analog/Digital Input 4-fold RS232 Open Interface KNX Push Button Plus KNX Contact Temperature Sensor Frames and Housings for the Module System Air Conditioner Controller EnOcean RF push button KNX Data Logger IR Remote Control Touch sensitive Sentido 2-fold Optical reading device LAN Secure Adapter NTC temperature sensor Touch sensitive Sentido 4-fold M-Bus reading software Find our Building Automation products and solutions in the respective catalogue. Datwyler 141

144 Power and data for modern elevators Elevator cable systems Unnoticed by elevator passengers, elevator cables from Datwyler do their job around the world every day. They reliably transfer power and data between the elevator cabin and the control system. Withstanding great mechanical stress, they provide faultless operation round the clock. No wonder Datwyler elevator cables are installed in the fastest elevators and the highest buildings in the world. 142 Datwyler

145 Space in cities is limited. High-rises are being erected around the globe. Elevators with ever greater performance are providing rapid access to the upper floors of these tall buildings. And so the requirements for the materials used are becoming increasingly tougher. As a leading manufacturer of elevator cable systems, Datwyler knows the needs. Not only must international standards be met, but knowledge of customers specific needs is essential. Our reliable elevator cable systems are known for smooth operation that adds significant comfort to the ride. Leading know-how Using various test methods, some of which were developed by Datwyler, we produce elevator cables for service under the toughest conditions. Our specialists define materials and designs that even under permanent dynamic loading show no signs of fatigue. We also offer halogen-free materials for special fire safety concepts. Spinnaker Tower, Portsmouth Selected reference projects Shanghai Oriental Pearl Tower Shanghai Post Tower, German Post headquarters Bonn Canary Wharf London Torre Major Mexiko City Capital Towers Dubai Spinnaker Tower Portsmouth New World Trade Center New York Diverse applications Datwyler elevator cable systems meet every requirement for electrical connections to the elevator cabin. Aside from power cables, high-quality data cables are being increasingly requested. Integral fibre optic cable can easily handle large volumes of data. These modern system solutions connect the elevator cabin to the controls and to the local data network so passengers can enjoy television and video services in the elevator. System solutions dynofil is our total system solution (including services) for electrical installations for elevators. Customer value in focus Datwyler has developed innovative system solutions for electrical installations for elevators. Comprehensive harnessing and logistics services with modern B2B connectivity round off the service offering of Datwyler. Datwyler 143

146 Product Overview Suspension devices for dynofil FL, FM, FH, module concept and compensation weight Installation tools for simple installation of FL, FM and FH dynofil cables Shaft lighting system Compensation weight 144 Datwyler

147 Pre-assembled machine room cabling (MRC) ready for installation Flat cables FL, FM, FH and module concept PVC and zero-halogen Pre-assembled hoistway cables/ wires (HW) ready for connection Pre-assembled travelling cables (TC) for travelling heights up to 400m Find our products for Elevator cable systems in the respective catalogue. Datwyler 145

Cable technology for highest safety requirements

Cable technology for highest safety requirements Cable technology for highest safety requirements Daetwyler We are a provider of high-grade quality system solutions and services in the areas of structured data cabling, telecom carriers, safety cabling,

More information

Fire alarm cables. for highest safety requirements TRADITION INNOVATION PASSION

Fire alarm cables. for highest safety requirements TRADITION INNOVATION PASSION Fire alarm cables for highest safety requirements TRADITION INNOVATION PASSION Datwyler Datwyler Cabling Solutions is an internationally operating company with its headquarters in Switzerland and affiliates

More information

The Quality Connection. BETAflam Fire Resistant Safety Cables

The Quality Connection. BETAflam Fire Resistant Safety Cables The Quality Connection BETAflam Fire Resistant Safety Cables BETAflam Contact Your personal customer number To offer you a more efficient service, we kindly ask you to mention your personal customer number

More information

The Quality Connection. BETAflam safety cables for highest demands

The Quality Connection. BETAflam safety cables for highest demands The Quality Connection BETAflam safety cables for highest demands 2 For solutions that will still be standard tomorrow. BETAflam safety cables Thanks to their proven quality, BETAflam safety cables are

More information

The Quality Connection. BETAflam Safety cables for highest demands

The Quality Connection. BETAflam Safety cables for highest demands The Quality Connection BETAflam Safety cables for highest demands 2 For solutions that will still be standard tomorrow. BETAflam Safety cables Thanks to their proven quality, BETAflam safety cables are

More information

fire resistant cables

fire resistant cables Building Technology fire resistant cables Special electrical and optical cables www.tecnikabel.com Special electrical and optical cables 2 INTRODUCTION Structured cabling solutions. Tecnikabel can provide

More information

600/1000V SR Insulated Flexibles Control Cables (2-4 Cores & Multicores)

600/1000V SR Insulated Flexibles Control Cables (2-4 Cores & Multicores) 600/1000V SR Insulated Flexibles Control Cables (2-4 Cores & Multicores) FFX400 1SZ1-R(PH60)(CU/SR/LSZH 600/1000V Class 2) FFX400 1SZ1-F(PH60)(CU/SR/LSZH 600/1000V Class 5) Silicone Rubber Insulation Plain

More information

High Performance LSZH Fire Resistant Cable

High Performance LSZH Fire Resistant Cable High Performance LSZH Fire Resistant Cable www.cavicel.com 104/2 FIRECEL SR 114H is the long and well established CAVICEL fire resistant cable in the market, since many years. These cables are third party

More information

Flame Retardant Overall Screened Instrumentation Cables (multicore)

Flame Retardant Overall Screened Instrumentation Cables (multicore) Flame Retardant Overall Screened Instrumentation Cables (multicore) RE-2X(St)H RE-2X(St)HSWAH LSZH Outer Sheath Tinned Copper Drain Wire LSZH Inner Sheath XLPE Insulation Plain Annealed Copper Aluminium/polyester

More information

AFIREFENIX SZ1-K 0,6/1 kv PH120 (AS+)

AFIREFENIX SZ1-K 0,6/1 kv PH120 (AS+) Page 1 / 7 Construction and tests. Standards: UNE 211025 Compliance with the Low Voltage Directive (LVD): 2014/35 / EU Construction Products Regulation (CPR) - Regulation (EU) Nº 305/2011: Reaction to

More information

Table of Contents. TELE-FONIKA KABLE SA (DMCC Branch). 4 TELE-FONIKA Kable Group 6 FLAME-X 950 SERIES 1 11 FLAME-X 950 SERIES 2

Table of Contents. TELE-FONIKA KABLE SA (DMCC Branch). 4 TELE-FONIKA Kable Group 6 FLAME-X 950 SERIES 1 11 FLAME-X 950 SERIES 2 FLAME-X 950 TELE-FONIKA KABLE SA (DMCC Branch). Table of Contents is the Regional Middle East Sales Office of Tele-Fonika Kable S.A. from Poland, 4-th largest manufacturer of electric cables and wires

More information

CONTENTS. Introduction Customer Service BS codes of practice BS Fire Performance Cable Selection Guide... 7

CONTENTS. Introduction Customer Service BS codes of practice BS Fire Performance Cable Selection Guide... 7 CONTENTS Page Introduction... 1 Customer Service... 2 BS codes of practice BS 8519... 5 Fire Performance Cable Selection Guide... 7 FlamBICC Introduction...8 FlamBICC 1...10 FlamBICC 2...12 FlamBICC 3...14

More information

Photovoltaic Cables EN H1Z2Z2-K

Photovoltaic Cables EN H1Z2Z2-K Photovoltaic Cables EN 50618 H1Z2Z2-K COMPANY PROFILE Caledonian, established in 1978, offers one of the most complete lines of fiber and copper cabling system solutions with over hundreds of different

More information

Fire Resistant Cables

Fire Resistant Cables Fire Resistant Cables Ducab (Abu Dhabi) Factory P.O. Box 9171, Abu Dhabi, UAE Tel: (971-2) 502 7777 Fax: (971-2) 502 7888 email: ducab@ducab.com Ducab Connect P.O. Box 11529, Dubai, United Arab Emirates

More information

THE TRUE FIRE SURVIVAL CABLE

THE TRUE FIRE SURVIVAL CABLE 25 YEAR THE TRUE FIRE SURVIVAL CABLE WARRANTY In 1989 we developed a unique process of manufacturing continuous mineral insulated copper cables. THE TRUE FIRE SURVIVAL CABLE We are the only UK manufacturer

More information

IEC UNE DESIGN. 1. Conductor. 2. Insulation. Cross-linked polyethylene (XLPE) 3. Outer sheath. Flexible PVC, black colour.

IEC UNE DESIGN. 1. Conductor. 2. Insulation. Cross-linked polyethylene (XLPE) 3. Outer sheath. Flexible PVC, black colour. 67 POWERFLEX RV-K POWERFLEX RV-K Industrial flexible cable for power transmission. 1 IEC 60502-1 - UNE 21123-2 DESIGN 1. Conductor 2 Electrolytic copper, class 5 (flexible), based on EN 60228 and IEC 60228.

More information

600/1000V XLPE Insulated, LSZH Sheathed, Double steel tape Armoured Power Cables (3 Cores)

600/1000V XLPE Insulated, LSZH Sheathed, Double steel tape Armoured Power Cables (3 Cores) Caledonian Flame Retardant Power & Control Cables www.caledonian-s.co.uk www.addison-s.com 600/1000V XLPE Insulated, LSZH Sheathed, Double steel tape Armoured Power Cables (3 Cores) FTX400 1RZ1MZ1-R (CU/XLPE/LSZH/DSTA/LSZH

More information

FUMEGUARD TM QUALITY APPROVED CABLES. Cables Limited MADE IN IRELAND SINCE 1934 IDH CABLES LIMITED LOW SMOKE HALOGEN FREE CABLES

FUMEGUARD TM QUALITY APPROVED CABLES. Cables Limited MADE IN IRELAND SINCE 1934 IDH CABLES LIMITED LOW SMOKE HALOGEN FREE CABLES Cables Limited MADE IN IRELAND SINCE 1934 QUALITY APPROVED CABLES IDH CABLES LIMITED FUMEGUARD TM LOW SMOKE HALOGEN FREE CABLES The longest-running original range of low voltage, low smoke, halogen free

More information

Caledonian Flame Retardant Coaxial Cables

Caledonian Flame Retardant Coaxial Cables Caledonian Flame Retardant Coaxial Cables www.caledonian-cables.co.uk www.addison-cables.com Flame Retardant RG59 Coaxial cables LSZH Outer Sheath Tinned Copper Braid Aluminium+polyester/Aluminium Tape

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60092-350 Second edition 2001-06 Electrical installations in ships Part 350: Shipboard power cables General construction and test requirements Installations électriques à bord

More information

IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission

IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission ADDISON Flame Retardant CAT5e Data Cables FTX-CAT5e U/UTP4P24 FTX-CAT5e f/utp4p24 FTX-CAT5e sf/utp4p24 LSZH Outer Aluminium/Polyester Tape Solid Copper Conductor PE Insulation Tinned Copper Drain Wire

More information

600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (Multicore)

600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (Multicore) 600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (Multicore) FGD400 1RV-R (CU/XLPE/PVC 600/1000V Class ) FGD400 1RVMV-R (CU/XLPE/PVC/SWA/PVC 600/1000V Class ) PVC Outer Sheath Plain Annealed

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 61892-4 First edition 2007-06 Mobile and fixed offshore units Electrical installations Part 4: Cables Commission Electrotechnique Internationale International Electrotechnical

More information

FIRE RESISTANT CABLES

FIRE RESISTANT CABLES Conducting Value The Last Cable Standing FIRE RESISTANT CABLES 100/7b ISO 9001:2008 Certificate No. CS1-249 MANAGEMENT SYSTEMS Assessed to ISO 9001:2008 Cert/LPCB ref. 217 GOST ISO 9001-2011 (ISO 9001:2008)

More information

Havells Fire Survival Cables

Havells Fire Survival Cables Fire Survival Cables Designed for Critical Installation of National Importance Airports / Thermal Power Plants Metro Rail Projects / Rail Terminals / Nuclear Interstate Bus Terminals / Installation Prone

More information

The Quality Connection. BETAflam Fire safety cables

The Quality Connection. BETAflam Fire safety cables The Quality Connection BETAflam Fire safety cables 2 We connect tomorrow s world already today. BETAflam Safety cables Halogen-free and environmentally friendly cables and single cores for applications

More information

DNVGL-CP-0401 Edition February 2016

DNVGL-CP-0401 Edition February 2016 CLASS PROGRAMME Type approval DNVGL-CP-0401 Edition February 2016 The electronic pdf version of this document, available free of charge from http://www.dnvgl.com, is the officially binding version. FOREWORD

More information

Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design.

Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design. ADDISON Flame Retardant RG59 B/U Coaxial cables Plain copper wire braid PE Solid Bare Copper PVC Outer Sheath APPLICATION The cables are designed for CCTV, security, smoke detection and evacuation monitoring

More information

Cablosam Tapes for Fire-Resistant Cables

Cablosam Tapes for Fire-Resistant Cables Cablosam Tapes for Fire-Resistant Cables 2 Cablosam Tapes for Fire-Resistant Cables We Enable Energy As one of the oldest industrial companies in Switzerland, founded in 1803, we focus on products and

More information

All Prysmian FP400 cables are manufactured under an ISO 9001 Quality System certified by BASEC and LPCB.

All Prysmian FP400 cables are manufactured under an ISO 9001 Quality System certified by BASEC and LPCB. Certificate No 077b Certificate No 517b > Prysmian FP400 is the original fire resistant armoured cable providing an easy to install and terminate, robust fire resistant wiring system. In addition to maintaining

More information

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red OFC-UT-CST Fire resistant Armoured Indoor/Outdoor steel tape armoured (CST) double LSHF-FR sheathed optical cable with 2 24 fibres. VDE: A/I-DQ(ZN)H(SR)H 3rd party verification of the fire tests by BUREAU

More information

Total Fire Solutions. Includes BS 8519 and the updated BS :

Total Fire Solutions. Includes BS 8519 and the updated BS : Total Fire Solutions Includes BS 8519 and the updated BS 5266-1:2011 www.aeicables.co.uk Introduction: Total Fire Solutions Power and control cable systems for life safety and fire-fighting applications

More information

BS /1000V XLPE Insulation LSZH Sheath Cables

BS /1000V XLPE Insulation LSZH Sheath Cables BS 8573 600/1000V XLPE Insulation LSZH Sheath Cables Caledonian www.addison-cables.com Company Profile Caledonian & Addison, branded under Caledoniea & Addimax, established in 1978, offers one of the most

More information

ENHANCED FIRE PERFORMANCE CABLE

ENHANCED FIRE PERFORMANCE CABLE FIRE PERFORMANCE CABLE Manufactured to BS 7629-1 Table 1 Plain Annealed Copper Conductors / Silicone Rubber Insulated / Glass Fibre Tape / Tinned Copper Circuit Protective Conductor / Double Layer of Copper/Polyester

More information

This is a preview - click here to buy the full publication. IEC Quality Assessment System for Electronic Components (IECQ System)

This is a preview - click here to buy the full publication. IEC Quality Assessment System for Electronic Components (IECQ System) QC 080000 Edition 3.0 2012-05 IECQ PUBLICATION IEC Quality Assessment System for Electronic Components (IECQ System) Hazardous Substance Process Management System Requirements (HSPM) INTERNATIONAL ELECTROTECHNICAL

More information

Caledonian fire Resistant signal & Data cables

Caledonian fire Resistant signal & Data cables fire Resistant signal & Data cables www.addison-tech.com fire Resistant Rs485 Databus cables Copper Wire Braid(optional) Individual AL/Polyester Tape(optional) Mica Glass Tape+PE/PE+Silicone Rubber Insulation

More information

Double insulated, electron-beam cross-linked, halogen free photovoltaic wire sunlight resistant. Single conductor, flame retardant insulation.

Double insulated, electron-beam cross-linked, halogen free photovoltaic wire sunlight resistant. Single conductor, flame retardant insulation. Technical Data Sheet BETAflam Solar 125 flex UL 4703 Description Double insulated, electron-beam cross-linked, halogen free photovoltaic wire sunlight resistant. Single conductor, flame retardant insulation.

More information

SAFE CABLING SYSTEMS IN TUNNELS UNDER FIRE

SAFE CABLING SYSTEMS IN TUNNELS UNDER FIRE - 249 - SAFE CABLING SYSTEMS IN TUNNELS UNDER FIRE Urs Welte Amstein + Walthert AG, Switzerland ABSTRACT The paper aims at a detailed analysis of the current know-how in the construction of tunnel cabling

More information

Catalogue Telecommunication Cables INTRODUCCIÓN

Catalogue Telecommunication Cables INTRODUCCIÓN Catalogue Telecommunication Cables INTRODUCCIÓN Conductores Tecnológicos S.A. www.contecsa.es Index of Cables Page Introduction 3 EAP / EAP-R 4 EAPSP / EAPSP-R 5 ISP / ICP 6 Conductores Tecnológicos S.A.

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Presley House Presley Way Crownhill Milton Keynes MK8 0ES United Kingdom Contact: Jeremy Hodge Tel: +44 (0) 1908 267300 Fax: +44 (0) 1908

More information

OUR SOLUTION: YOUR CABLE. PRODUCTION OVERVIEW

OUR SOLUTION: YOUR CABLE. PRODUCTION OVERVIEW OUR SOLUTION: YOUR CABLE. PRODUCTION OVERVIEW Our expertise Our expertise Company MUCKENHAUPT & NUSSELT is a cable production company in Wuppertal, which has been successful in the market since 1926 and,

More information

Caledonian. FIREFLIX ire Resistant Coaxial Cables

Caledonian. FIREFLIX ire Resistant Coaxial Cables Caledonian FIREFLIX ire Resistant Coaxial Cables table OF COntents Fire resistant Coaxial Cables Fire Resistant RG59 B/U coaxial cables...25 Fire Resistant RG6 A/U coaxial cables...28 Fire Resistant RG6

More information

DNVGL-CP-0399 Edition March 2016

DNVGL-CP-0399 Edition March 2016 CLASS PROGRAMME Type approval DNVGL-CP-0399 Edition March 2016 The electronic pdf version of this document, available free of charge from http://www.dnvgl.com, is the officially binding version. FOREWORD

More information

(Notices) EUROPEAN COMMISSION

(Notices) EUROPEAN COMMISSION 14.8.2012 Official Journal of the European Union C 245/1 IV (Notices) NOTICES FROM EUROPEAN UNION INSTITUTIONS, BODIES, OFFICES AND AGENCIES EUROPEAN COMMISSION Commission communication in the framework

More information

FIRE PERFORMANCE CABLE

FIRE PERFORMANCE CABLE FIRE PERFORMANCE CABLE Manufactured to BS 7629-1 Table 1 Plain Annealed Copper Conductors / Silicone Rubber Insulated / Double Layer of Aluminium/ Polyester Laminated Tapes / Circuit Protective Conductor

More information

Core identification code. J-YY...BD Indoor Cable. J-YY...BD Indoor Cable. VDE 0815 Mutual capacitance. J-YY...BD Indoor Cable. Cu conductor 0.

Core identification code. J-YY...BD Indoor Cable. J-YY...BD Indoor Cable. VDE 0815 Mutual capacitance. J-YY...BD Indoor Cable. Cu conductor 0. Indoor cables J-YY...BD Indoor J-Y(ST)Y..LG Indoor Comparable products UNITRONIC J-2Y(ST)Y...ST III BD see page 271 Indoor telephone cables transmit analogue or digital signals In news and communication

More information

INTRODUCTION. Our diverse range of world-class Specialty Insulated Wires and Cablesinclude: LV Cables -

INTRODUCTION. Our diverse range of world-class Specialty Insulated Wires and Cablesinclude: LV Cables - MARINE CABLES Your Power Partner on the Seas INTRODUCTION We, a member of the Al-Bahja Group of Companies, are an ISO:900:2008 BASEC, UK certified integrated quality producer of LV and MV Cables, Wires&

More information

IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission

IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission Flame Retardant RS485 Databus Cables Copper Wire Braid(optional) Individual AL/Polyester Tape(optional) Foam PE/Foam skin PE. Stranded Tinned Copper AL/Polyester Tape With Tinned Copper Drain Wire LSZH

More information

ITU-T L.63. Safety practice for outdoor installations

ITU-T L.63. Safety practice for outdoor installations International Telecommunication Union ITU-T L.63 TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU (10/2004) SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT

More information

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red Indoor/Outdoor steel tape armoured (CST) double LSHF-FR sheathed optical cable with 2 24 fibres. VDE: A/I-DQ(ZN)H(SR)H 3rd party verification of the fire tests by BUREAU VERITAS December 2014 OFC-UT-CST

More information

Introduction.

Introduction. Introduction The safety of occupants and users of public, commercial and industrial premises is of paramount importance. One important safety feature is the appropriate use of fire performance cables for

More information

HRS Hand Rail System 1

HRS Hand Rail System 1 HRS Hand Rail System 1 Safety in tunnels Hand rail system for rail tunnels In accordance with the requirements of the TSI (technical specification for interoperability), all tunnels in the trans-european

More information

GUARDIANTM QUALITY APPROVED CABLES. Cables Limited MADE IN IRELAND SINCE 1934 IDH CABLES LIMITED MECHANICALLY PROTECTED CABLES

GUARDIANTM QUALITY APPROVED CABLES. Cables Limited MADE IN IRELAND SINCE 1934 IDH CABLES LIMITED MECHANICALLY PROTECTED CABLES Cables Limited MADE IN IRELAND SINCE 1934 QUALITY APPROVED CABLES IDH CABLES LIMITED GUARDIANTM MECHANICALLY PROTECTED CABLES The original BS-8436, IS-273 multifunctional, easy to install, connect-and-protect

More information

FIRE RESISTANT CABLES FP400

FIRE RESISTANT CABLES FP400 FIRE RESISTANT CABLES FP400 FIRE RESISTANT CABLES FP400 BS7846-F2 CABLE CHARACTERISTICS FP400 APPROVALS INSTALLATION Certificate No 077b Certificate No 517b > Prysmian FP400 is the original fire resistant

More information

Record of Amendments. Version Date Amendment Section/page affected

Record of Amendments. Version Date Amendment Section/page affected Industry support for effective compliance BTHA Guidance on The Restriction Of The Use Of Certain Hazardous Substances In Electrical and Electronic Equipment (recast) (RoHS) Directive 2011/65/EU Comparison

More information

Flexflame. Arctic Grade Cables for Extreme Conditions. Photo: Sakhalin Energy Investement Company Ltd.

Flexflame. Arctic Grade Cables for Extreme Conditions. Photo: Sakhalin Energy Investement Company Ltd. Flexflame Arctic Grade Cables for Extreme Conditions Photo: Sakhalin Energy Investement Company Ltd. Linking the future Draka Norsk Kabel is a part of Prysmian Group, a worldwide leader in the cable industry.

More information

Author Owner Issue Authority Name: Gordon MacKenzie Title: Senior Engineer Engineering Design and Standards

Author Owner Issue Authority Name: Gordon MacKenzie Title: Senior Engineer Engineering Design and Standards 1. SCOPE This Specification details requirements for General Wiring cables up to and including 450/750V for use on lighting and general power wiring installations complying with BS 7671 but not forming

More information

FIRE RESISTANT CABLES FP300

FIRE RESISTANT CABLES FP300 FIRE RESISTANT CABLES FP300 Fire resistant LSOH power cables for fixed wiring FIRE RESISTANT CABLES FP300 LPCB Ref No: 077e/01 FP300 > Prysmian FP300 is designed for cabling essential safety circuits associated

More information

FIRE RESISTANT CABLES FP PLUS. New Generation. Now with enhanced Insudite TM insulation

FIRE RESISTANT CABLES FP PLUS. New Generation. Now with enhanced Insudite TM insulation FIRE RESISTANT CABLES FP PLUS New Generation Now with enhanced Insudite TM insulation ENHANCED FIRE RESISTANT CABLES FP PLUS BS7629-1:2008 FP PLUS > Certificate No 077g/02 The new generation of FP PLUS

More information

WORLDWIDE CABLE EXPERTS

WORLDWIDE CABLE EXPERTS WORLDWIDE CABLE EXPERTS An introduction to our cable testing and certification services CORPORATE BROCHURE PAGE I TWO Contents 2 Introducing BASEC 3 What we do 4 Management Systems Certification 5 Product

More information

BS EN :2004. Test On Electric And Optical Fibre Cables Under Fire Conditions. WF Report Number. Date: 14 th November 2008.

BS EN :2004. Test On Electric And Optical Fibre Cables Under Fire Conditions. WF Report Number. Date: 14 th November 2008. BS EN 60332-1-2:2004 Test On Electric And Optical Fibre Cables Under Fire Conditions WF Report Number 177603 Date: 14 th November 2008 Test Sponsor: FTC Fabbrica Trentina Conduttori Srl 0249 Page 2 of

More information

Requirements for Electrical Installations

Requirements for Electrical Installations BRITISH STANDARD BS 7671:2018 Corrigendum (December 2018) Requirements for Electrical Installations IET Wiring Regulations Eighteenth Edition The Institution of Engineering and Technology and BSI NO COPYING

More information

FIRE RESISTANT CABLES FP200 GOLD

FIRE RESISTANT CABLES FP200 GOLD FIRE RESISTANT CABLES FP200 GOLD FIRE RESISTANT CABLES FP200 GOLD BS7629-1:2008 FP200 GOLD FIRE RESISTANT CABLES Key Applications Fire detection and fire alarm systems for buildings Voice alarm systems

More information

LSOH Flexible Cables

LSOH Flexible Cables LSOH Flexible Cables Low Voltage (300/500 V) 3182B, 3183B, 3184B Piresafe TM Flex Cable Approvals Key Applications > Supply leads for medium duty domestic and office appliances, lighting fittings and portable

More information

Lloyd s Register Type Approval System Test Specification Number 3

Lloyd s Register Type Approval System Test Specification Number 3 Working together for a safer world Lloyd s Register Type Approval System Test Specification Number 3 July 2015 Performance Test Specification for Equipment to be used in Marine Applications: Electric Cables

More information

Caledonian Fire resistant Coaxial Cables

Caledonian Fire resistant Coaxial Cables Caledonian Fire resistant Coaxial Cables www.caledonian-cables.net www.addison-cables.com Fire resistant rg59 b/u Coaxial Cables RG59 B/U FR LSZH Sheath Fire Resistant Tape Copper Clad Steel/Bare Copper

More information

Solutions for airports and railway stations

Solutions for airports and railway stations Solutions for airports and railway stations Solutions for airports and railway stations Airports and railway stations aren t just places where countless people pass through every day. They also provide

More information

(Publication of titles and references of harmonised standards under Union harmonisation legislation) (Text with EEA relevance) (2017/C 298/02)

(Publication of titles and references of harmonised standards under Union harmonisation legislation) (Text with EEA relevance) (2017/C 298/02) C 298/14 EN Official Journal of the European Union 8.9.2017 Commission communication in the framework of the implementation of Directive 2014/35/EU of the European Parliament and of the Council on the

More information

PRODUCT CATALOGUE Norröna

PRODUCT CATALOGUE  Norröna PRODUCT CATALOGUE Norröna WWW.SCANKAB.COM Table of contents MARINE AND OFFSHORE CABLES 1 TOXFREE XZ1-K (AS) - 0.6/1 kv 1 TOXFREE MARINE XO2TCuZ1-K (AS) - 150/250 V 5 4x2xAWG 24/1 CAT6 S/FTP LSZH-SHF1 -

More information

Overmoulded Cable Assembly Selector Guide

Overmoulded Cable Assembly Selector Guide CABLE ASSEMBLY Overmoulded Assembly Selector Guide Assembly SOURIAU Services An availability around the world - Global manufacturing locations - Vast network of authorised distribution partners. Reliable

More information

AFUMEX LSX LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS:

AFUMEX LSX LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS: PRODUCT DATASHEET & APPLICATIONS GUIDE LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 KEY BENEFITS: BASEC approved for the full size range of BS8436 (1.0mm 2 to 2.5mm 2 ) Additionally tested for

More information

Building Services Brochure

Building Services Brochure Building Services Brochure A Midland Brand A Midland Brand Redefining Flow Control Contents Section Page Introduction to Building Services 3 Wet & Dry RIser Equipment 4 Gas Detection & Pressure Proving

More information

MEDIUM VOLTAGE CABLES INSTRUMENTATION CABLES RUBBER CABLES FIRE RESISTANT CABLES

MEDIUM VOLTAGE CABLES INSTRUMENTATION CABLES RUBBER CABLES FIRE RESISTANT CABLES RUBBER CABLES FIRE RESISTANT CABLES INSTRUMENTATION CABLES MEDIUM VOLTAGE CABLES Halley Cables, established in 2006, is a dynamic company, specialized in power supply, which focuses on customers satisfaction.

More information

Tratos Railway Cables

Tratos Railway Cables January 2013 Tratos Railway Cables Cables for a moving world www.tratos.eu Introduction Tratos Cavi is a company specialising in the production of power, signalling, control and telecommunications cables

More information

DNVGL-CP-0402 Edition February 2016

DNVGL-CP-0402 Edition February 2016 CLASS PROGRAMME Type approval DNVGL-CP-0402 Edition February 2016 The electronic pdf version of this document, available free of charge from http://www.dnvgl.com, is the officially binding version. FOREWORD

More information

AFUMEX LSX BASEC APPROVED LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS:

AFUMEX LSX BASEC APPROVED LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS: PRODUCT DATASHEET & APPLICATIONS GUIDE BASEC APPROVED LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 KEY BENEFITS: BASEC approved for the full size range of BS8436 (1.0mm 2 to 2.5mm 2 ) Additionally

More information

CORRIGENDA. (Publication of titles and references of harmonised standards under Union harmonisation legislation)

CORRIGENDA. (Publication of titles and references of harmonised standards under Union harmonisation legislation) C 173/162 EN Official Journal of the European Union 13.5.2016 CORRIGENDA Corrigendum to Commission communication in the framework of the implementation of Directive 2006/95/EC of the European Parliament

More information

SPECIAL ELECTRICAL AND OPTICAL CABLES

SPECIAL ELECTRICAL AND OPTICAL CABLES SPECIAL ELECTRICAL AND OPTICAL CABLES INTRODUCTION The new high-speed trains and the sensible increase of the traffic, with congested lines, is the result of the latest development of the rail sector.

More information

Section 8: Switchgear Connections (Straight & Elbows)

Section 8: Switchgear Connections (Straight & Elbows) 8: Switchgear Connections (Straight & Elbows) HEAT SHRINKABLE RSRB Inline and Right Angle Bushing Boots 126 PUSH ON ELBOWS RCAB-41 Elastomeric Flexible Bushing Boot - up to 17.5kV 127 RCAB-51 Inline Cold

More information

HELKAMA. Optical Fibre Cables

HELKAMA. Optical Fibre Cables 1 Contents Optical fibres and their characteristics Cable constructions Cable tests Installation, jointing and terminating Manufacturing (pictures) 2 Multimode Fibre (GK) Attenuation and Bandwidth Fibre

More information

speed pipe indoor system. Secure indoor networks.

speed pipe indoor system. Secure indoor networks. speed pipe indoor system. Secure indoor networks. www.gabocom.com gabo Systemtechnik 2 3 Networks of the future. Safety obliges. Fiber-optic more and more approaches the end-user also inside buildings

More information

WKE Spelsberg. The name in maintaining electrical integrity.

WKE Spelsberg. The name in maintaining electrical integrity. WKE Spelsberg. The name in maintaining electrical integrity. Reference object: Central train station, Berlin Modern architecture places strictly demand the reliability of electrical systems. That is especially

More information

Traction Cable Radox 3 GKW

Traction Cable Radox 3 GKW General Properties : Excellent high temperature, low temperature, ozone and weathering resistance, zero halogen, flame retardant, solder iron resistant, easily strippable, flexible. Application : Single

More information

LSOH Wiring Cables. LSOH Conduit Wire (HO7Z-R) Low Voltage (450/750 V) Cable Approvals. Key Applications. Conductor. Insulation. Core Identification

LSOH Wiring Cables. LSOH Conduit Wire (HO7Z-R) Low Voltage (450/750 V) Cable Approvals. Key Applications. Conductor. Insulation. Core Identification LSOH Wiring Cables Low Voltage (450/750 V) LSOH Conduit Wire (HO7Z-R) Cable Approvals Cable approved to BS7211 Key Applications > Manufactured to BS EN 50525-3-41 90 C cross linked (previously BS 7211)

More information

Copper LAN cable. This specification describes the general requirements for AMP NETCONNECT* copper LAN cable.

Copper LAN cable. This specification describes the general requirements for AMP NETCONNECT* copper LAN cable. Product Specification 108-93018 25/Aug/2011 Rev H Copper LAN cable 1. SCOPE 1.1. Content This specification describes the general requirements for AMP NETCONNECT* copper LAN cable. 2. APPLICABLE DOCUMENTS

More information

Data sheet OpDAT universal cable 1x24 OM4 - bend insensitive

Data sheet OpDAT universal cable 1x24 OM4 - bend insensitive Illustrations Principle diagram Page 1/7 Product specification installation cable U-DQ(ZN)BH universal fiber optic cable for indoors/outdoors with central or stranded loose tube bend insensitive fiber

More information

The safe choice. Now real safety is possible and easy. The evolution of safety. Fire resistant LSOH cables. Ecology Line. Traditional standard cables

The safe choice. Now real safety is possible and easy. The evolution of safety. Fire resistant LSOH cables. Ecology Line. Traditional standard cables The safe choice Pirelli has been producing Low Smoke Zero Halogen (LSOH) cables for more than 20 years. LSOH cables have generally been a niche product, for special uses. The new Afumex range, building

More information

OFFSHORE CABLES. Top Cable Central Headquarters. Leonardo Da Vinci, number Rubí (Barcelona) Spain

OFFSHORE CABLES.   Top Cable Central Headquarters. Leonardo Da Vinci, number Rubí (Barcelona) Spain Top Cable Central Headquarters Leonardo Da Vinci, number 1 08191 Rubí (Barcelona) Spain OFFSHORE CABLES Tel +4 9 586 21 78 +4 9 586 21 68 Fax +4 9 586 21 65 sales@topcableoffshoremarine.com http://www.topcableoffshoremarine.com

More information

HULME MARTIN HEAT SEALERS

HULME MARTIN HEAT SEALERS HM1000P Operating Instructions HULME MARTIN HEAT SEALERS HULME MARTIN HEAT SEALERS www.hulmemartin.co.uk SAFETY INSTRUCTIONS HEAT SEALING EQUIPMENT A. Protection against hazards arising from the electrical

More information

FIRE RESISTANT CABLES FP200 GOLD

FIRE RESISTANT CABLES FP200 GOLD FIRE RESISTANT CABLES FP200 GOLD FIRE RESISTANT CABLES FP200 GOLD BS7629-1 FP200 GOLD Clause 26.2 > The original highly durable and dressable, easy to terminate and install fire resistant cable. Approved

More information

Telecommunication Cables

Telecommunication Cables Telecommunication Cables Telecommunication Cables Introduction 3 EAP / EAP-R 4 EAPSP / EAPSP-R 5 ISP / ICP 6 Page ELECWIRES 2 www.elecwires.es INTRODUCCIÓN Telecommunication Cables Telephone cables suitable

More information

PRAKAB PRAŽSKÁ KABELOVNA, s.r.o. COMPANY PROFILE 2015

PRAKAB PRAŽSKÁ KABELOVNA, s.r.o. COMPANY PROFILE 2015 PRAKAB PRAŽSKÁ KABELOVNA, s.r.o. COMPANY PROFILE 2015 SKB-GROUP 25.08.2015 Seite 2 Presence throughout Europe PRAKAB is a member of SKB-GROUP 25.08.2015 Seite 3 Main Export Markets 1. DE: 32 225 EUR (37,96%)

More information

Cable tray solutions. For tunnels GUIDE. The global specialist in electrical and digital building infrastructures

Cable tray solutions. For tunnels GUIDE. The global specialist in electrical and digital building infrastructures Cable tray solutions For tunnels GUIDE The global specialist in electrical and digital building infrastructures II Cable routing solutions for tunnels The Legrand Group, the global specialist in electrical

More information

BS FP600 achieves the maximum 120 minute rating under the BS test conditions, which is required for fire fighting applications.

BS FP600 achieves the maximum 120 minute rating under the BS test conditions, which is required for fire fighting applications. FIRE RESISTANT CABLES FP600 FIRE RESISTANT CABLES FP600 BS7346-6 FP600 > Prysmian FP600 is a unique enhanced performance fire resistant power cable, designed specifically to meet the more onerous fire

More information

FieldLink Cable solutions for Automation & Drives

FieldLink Cable solutions for Automation & Drives FieldLink Cable solutions for Automation & Drives The LEONI Group Cable competence for different industrial markets Our group of companies employs more than 64,000 people in 33 countries. Corporate vision,

More information

COMMUNICATION FROM THE COMMISSION TO THE EUROPEAN PARLIAMENT, THE COUNCIL, THE EUROPEAN ECONOMIC AND SOCIAL COMMITTEE AND THE COMMITTEE OF THE REGIONS

COMMUNICATION FROM THE COMMISSION TO THE EUROPEAN PARLIAMENT, THE COUNCIL, THE EUROPEAN ECONOMIC AND SOCIAL COMMITTEE AND THE COMMITTEE OF THE REGIONS EUROPEAN COMMISSION Strasbourg, 25.10.2016 COM(2016) 710 final ANNEX 5 ANNEX to the COMMUNICATION FROM THE COMMISSION TO THE EUROPEAN PARLIAMENT, THE COUNCIL, THE EUROPEAN ECONOMIC AND SOCIAL COMMITTEE

More information

OIL & GAS INDUSTRY OTHER INDUSTRIES

OIL & GAS INDUSTRY OTHER INDUSTRIES For ATEX Areas OIL & GAS INDUSTRY OTHER INDUSTRIES OIL & GAS INDUSTRY POTENTIALLY HAZARDOUS Class I GASES VAPORS LIQUIDS Petrosumsave Zone 0 An area in which an explosive mixture is continuously present,

More information

Royal Grass. ...for responsible green cities

Royal Grass. ...for responsible green cities Royal Grass...for responsible green cities Royal Grass is replacing natural grass in the city scape in a variety of applications ranging from community parks to medians, even green roofs. From an environmental

More information

Üntel is ready for CPR

Üntel is ready for CPR 2016 Üntel is ready for CPR Hakan Kubas Marketing Manager 01.11.2016 Construction Products Regulation What is the CPR? The Construction Products Regulation (CPR) lays down conditions for the placing or

More information

More than Just a Cable Supplier

More than Just a Cable Supplier More than Just a Cable Supplier Leading producer of cables and cable systems The TELE-FONIKA Kable Group has been present on the domestic and international cable industry market for more than 25 years.

More information