PAIRED UNJACKETED. Insulation Nominal Anixter. Paired Conductors Thickness O.D. Number AWG Strand No. IN IN

Size: px
Start display at page:

Download "PAIRED UNJACKETED. Insulation Nominal Anixter. Paired Conductors Thickness O.D. Number AWG Strand No. IN IN"

Transcription

1 PVC Stranded and Solid Conductors Listed as Misc. Wire PAIRED UNJACKETED Burglar alarm systems wiring; to sensors, control. BURGLAR ALARM 1. CONDUCTOR: Stranded copper conductors (1/c tinned + 1/c bare) typical. (7-wire construction). 2. INSULATION: Polyvinyl chloride (PVC). 3. COLOR CODE: Available: White, Brown or Clear. 4. STANDARDS: Listed misc. wires. 5. TEMPERATURE: 80 C 6. VOLTAGE: 300 Volts Insulation Nominal Anixter Paired Conductors Thickness O.D. Number AWG Strand No. IN IN x x Solid x x Anixter Inc

2 PVC/PVC Stranded Conductors Burglar alarm cables. BURGLAR ALARM MULTI CONDUCTOR JACKETED 1. CONDUCTOR: Stranded bare copper. 2. INSULATION: Polyvinyl chloride (PVC). 3. OVERALL JACKET: Polyvinyl chloride (PVC). 4. TEMPERATURE: 60 C 5. VOLTAGE: 300 Volts Insulation Overall Jacket Nominal Anixter Conductor Size Thickness Thickness O.D. Number AWG Strand No. IN IN IN x x x x x x x x x x x Anixter Inc. 1999

3 FIRE ALARM PVC Solid Conductor FPL, FPLR, FPLP, UL Listed PARALLEL (ZIP CORD) For use in power limited fire and burglar alarms and smoke detectors and security systems. 1. CONDUCTOR: Stranded bare copper. 2. INSULATION: Polyvinyl chloride (PVC) or PVC alloy. 3. STANDARDS: NEC FPL, FPLR or FPLP, UL listed. 4. TEMPERATURE: 20 C to 60 C, dry locations. Conductor Insulation Nominal Size Thickness O.D. Approximate Anixter Insulation Weight Lbs. Number AWG Rating Type IN IN 1000 Ft. 9C FPL Red PVC x C FPL Red PVC x C FPL Red PVC x FPLR Red PVC x FPLP Red FRPVC x FPLP Red FRPVC x Anixter Inc

4 PVC Solid Conductor FPLR, FPLP, UL Listed FIRE ALARM NONSHIELDED PLENUM AND NONPLENUM For use in power limited fire and burglar alarms and smoke detectors and security systems. FIRE ALARM 1. CONDUCTOR: Solid bare copper. 2. INSULATION: Polyvinyl chloride (PVC) or PVC or FRPVC alloy, red PVC or PVC alloy jacket. 3. OVERALL JACKET: PVC or FRPVC. 4. STANDARDS: NEC FPLR or FPLP, UL listed. 5. TEMPERATURE: 75 C Shielded also available Overall Conductor Number Insulation Jacket Nominal Approx. SIze of Insulation Thickness Thickness O.D. Wt. Lbs. Anixter Number AWG Conductors Rating Type IN IN IN 1000 Ft. FA-1202C-1-1N-XX 12 2 FPLR FRPVC FA-1202C-1-2N-XX 12 2 FPLP PVC FA-1402C-1-1N-XX 14 2 FPLR FRPVC FA-1402C-1-2N-XX 14 2 FPLP PVC FA-1403C-1-1N-XX 14 3 FPLR FRPVC FA-1403C-1-2N-XX 14 3 FPLP PVC FA-1602C-1-1N-XX 16 2 FPLR FRPVC FA-1602C-1-2N-XX 16 2 FPLP PVC FA-1604C-1-1N-XX 16 4 FPLR FRPVC FA-1604C-1-2N-XX 16 4 FPLP PVC FA-1802C-1-1N-XX 18 2 FPLR FRPVC FA-1802C-1-2N-XX 18 2 FPLP PVC FA-1804C-1-1N-XX 18 4 FPLR FRPVC FA-1804C-1-2N-XX 18 4 FPLP PVC FA-1806C-1N-XX 18 6 FPLR FRPVC FA-1806C-2N-XX 18 6 FPLP PVC FA-1808C-1N-XX 18 8 FPLR FRPVC FA-1808C-2N-XX 18 8 FPLP PVC FA-2204C-1N-XX 22 4 FPLR FRPVC FA-2204C-2N-XX 22 4 FPLP PVC Anixter Inc. 1999

5 FIRE ALARM PVC Solid Conductor FPL, UL Listed LOW CAPACITANCE (SHIELDED) For use in power limited fire and burglar alarms and smoke detectors and security systems. 1. CONDUCTOR: Solid bare copper. 2. INSULATION: Polyvinyl chloride (PVC), red PVC jacket. 3. OVERALL JACKET: Polyvinyl chloride (PVC). 4. COLOR CODE: Red, Black, Yellow, Blue. 5. SHIELD: Aluminum/Mylar with tinned copper drain wire. 6. STANDARDS: NEC FPL, UL listed. 7. CAPACITANCE: pf/ft. 8. TEMPERATURE: 20 C to 60 C, dry locations. Overall Conductor Insulation Jacket Nominal Size Number Thickness Thickness O.D. Approx. Anixter of Insulation Wt. Lbs. Number AWG Conductors Rating Type IN IN IN 1000 Ft FPL PVC FPL PVC FPL PVC FPL PVC FPL PVC Anixter Inc. 1999

6 LOW VOLTAGE-SECURITY/ALARM PLENUM PVC Bare Copper Conductor UL Listed, UL NEC Type, CMP, CLZP For use in Broadcast, Sound/Audio applications as well as Intercom/P.A and Power Limited Controls. 1. CONDUCTOR: Bare Copper. 2. INSULATION: FRPVC. 3. OVERALL JACKET: FRPVC. 4. STANDARDS: UL Type CMP or CL2P, CMP: AWG, CL2P: AWG, NEC Article(s) 800, TEMPERATURE: 75 C. Shielded also available FIRE ALARM Overall Conductor Number Insulation Jacket Nominal Approx. SIze of No. of Thickness Thickness O.D. Wt. Lbs. Anixter Number AWG Conductors Strands Rating IN IN IN 1000 Ft. AL-1202C-2-2N CL2P AL-1402C-2-2N-XX CL2P AL-1403C-2-2N-XX CL2P AL-1602C-2-2N-XX CMP AL-1603C-2-CN-XX CMP AL-1604C-2-2N-XX CMP AL-1802C-1-2N-XX 18 2 Solid CMP AL-1802C-2-2N-XX CMP AL-1803C-2-2N-XX CMP AL-1804C-2-2N-XX CMP AL-1805C-2-2N-XX CMP AL-1806C-2-2N-XX CMP AL-1808C-2-2N-XX CMP AL-1809C-2-2N-XX CMP AL-2202C-2-2N-XX CMP Anixter Inc

7 LOW VOLTAGE-SECURITY/ALARM NONPLENUM PVC Bare Copper Conductor UL NEC Type, CMR, CL3R For use in Broadcast, Sound/Audio applications as well as Intercom/P.A and Power Limited Controls. 1. CONDUCTOR: Bare copper. 2. INSULATION: PVC. 3. OVERALL JACKET: PVC. 4. STANDARDS: UL NEC Type CMR or CL3R, CMR: AWG, CLR: AWG, NEC Article(s) 800, TEMPERATURE: 75 C. Shielded also available FIRE ALARM Overall Conductor Number Insulation Jacket Nominal Approx. SIze of No. of Thickness Thickness O.D. Wt. Lbs. Anixter Number AWG Conductors Strands Rating IN IN IN 1000 Ft. AL-1202C-2-1N-XX CL3R AL-1203C-2-1N-XX CL3R AL-1402C-2-1N-XX CL3R AL-1403C-2-1N-XX CL3R AL-1404C-2-1N-XX CL3R AL-1602C-2-1N-XX CMR AL-1603C-2-1N-XX CMR AL-1604C-2-1N-XX CMR AL-1802C-1-1N-XX 18 2 Solid CMR AL-1802C-2-1N-XX CMR AL-1803C-2-1N-XX CMR AL-1804C-2-1N-XX CMR AL-1805C-2-1N-XX CMR AL-1806C-2-1N-XX CMR AL-1808C-2-1N-XX CMR AL-2202C-2-1N-XX CMR Anixter Inc. 1999

8 HVAC ECHELON LONWORKS Interface cables for LonWorks chip. Anixter Conductor Size Number of Number AWG Pairs Shielding Usage 9D Nonshielded Nonplenum 9F Shielded Nonplenum 9D Nonshielded Nonplenum 9F Shielded Nonplenum 9H Nonshielded Plenum 9J Shielded Plenum 9H Nonshielded Plenum 9J Shielded Plenum Building control cables. HONEYWELL *K3600, AK3700 and AK3900 series cables are available upon request. Building control, alarm and sensor cables. JOHNSON CONTROLS *All riser and plenum rated fire alarm cables. *Metasys sensor and relay, N1 and N2 Bus cables. Anixter Inc

9 THERMOSTAT Low Voltage Solid Copper Multi Conductor PT, PBT, PJT For use with thermostatic controls in connection with heating and air-conditioning installations. Type PJT may also be used for bell and annunciator systems. 1. CONDUCTOR: Solid copper, color-coded thermoplastic insulation, conductors twisted. 2. OVERALL JACKET: Overall no jacket, or braid waxed jacket, or plastic jacket, as applicable. PT PLASTIC INSULATION NO OVERALL JACKET Conductor Size Nominal O.D. Approximate Anixter Number Weight Lbs. Number AWG of Conductors IN 1000 Ft. 6T-1802T T-1803T T-1804T T-1805T T-1806T T-1807T T-1808T PTB PLASTIC INSULATION BRAID WAXED JACKET Conductor Size Nominal O.D. Approximate Anixter Number Weight Lbs. Number AWG of Conductors IN 1000 Ft. 6T-1802B T-1803B T-1804B T-1805B T-1806B T-1807B T-1808B PJT PLASTIC INSULATION PLASTIC JACKET Approximate Conductor Size Nominal O.D. Anixter Number Weight Lbs. Number AWG of Conductors IN 1000 Ft. 6T-1802J T-1803J T-1804J T-1805J T-1806J T-1807J T-1808J Anixter Inc. 1999

Fire Alarm Cables. Features: Countdown. New Labeling System on box. Color Coded Boxes. Zone and Room Markings

Fire Alarm Cables. Features: Countdown. New Labeling System on box. Color Coded Boxes. Zone and Room Markings Fire Alarm Cables Our Fire Alarm Cables are manufactured in a wide variety of gauge sizes, shielding configurations and jacketing materials including plenum, riser and general purpose. Genesis also manufactures

More information

Fire Alarm/Life Safety Cable 6

Fire Alarm/Life Safety Cable 6 Electronics Fire Alarm/Life Safety 6 Index Page Alarm and Security Solutions Guide 114-116 Fire alarm systems have expanded from a rather simple and unsophisticated business configured upon large, electromechanical

More information

Honeywell Cable & Custom Electronics

Honeywell Cable & Custom Electronics Honeywell Cable & Custom Electronics Genesis Series HVAC/Control Cable ZONE Residential Creating Comfort... Appearance is everything, however, when it comes to HVAC itʼs what you donʼt see that allows

More information

Security & Control Cables

Security & Control Cables Security & Control Cables Our multi-conductor cables are manufactured in a wide variety of gauge sizes, shielding configurations and jacketing materials including plenum, riser and general purpose. Applications

More information

Company Profile. We are dedicated to providing our customers competitive price and excellent service.

Company Profile. We are dedicated to providing our customers competitive price and excellent service. 1 Company Profile Hangzhou Kingtone Electronics Co., Limited is a Chinese wire & cable manufacturer specializing in manufacturing Coaxial Cable, Lan Cable, Alarm/Security Cable, Power Cable, Speaker Cable

More information

Product Guide. Fire Alarm Cables. Initiating Device, SLC Lines, and NAC Cables.

Product Guide. Fire Alarm Cables. Initiating Device, SLC Lines, and NAC Cables. Fire Alarm Cables Initiating Device, SLC Lines, and NAC Cables Product Guide STANDARDS Fire Alarm Systems A fire alarm system is number of devices working together to detect and warn people through visual

More information

Genesis. Series Low Voltage Cable. Honeywell Cable Catalog

Genesis. Series Low Voltage Cable. Honeywell Cable Catalog Honeywell Cable Catalog 2011-2012 SECURITY, FIRE, HOME THEATER, SOUND, CCTV, CATV, VOICE AND DATA AND THERMOSTAT WIRE Genesis Series Low Voltage Cable backbone Make no bones about it. Honeywell Genesis

More information

SOUND/SECURITY FIRE ALARM/LIFE SAFETY TEMPERATURE CONTROLS COAXIAL DATACOM HARDWARE FIBER OPTIC SPECIAL APPLICATION CATALOG, VOL.

SOUND/SECURITY FIRE ALARM/LIFE SAFETY TEMPERATURE CONTROLS COAXIAL DATACOM HARDWARE FIBER OPTIC SPECIAL APPLICATION CATALOG, VOL. CATALOG, VOL. 10 WAREHOUSE / BRANCH LOCATIONS Anaheim, CA Atlanta, GA Boston, MA Phoenix, AZ Portland, OR Seattle, WA Tracy, CA SOUND/SECURITY FIRE ALARM/LIFE SAFETY TEMPERATURE CONTROLS COAXIAL DATACOM

More information

Home Theater Cables. Your complete solution for high-end audio transmission, stereo, professional audio systems and home theater systems.

Home Theater Cables. Your complete solution for high-end audio transmission, stereo, professional audio systems and home theater systems. Home Theater Cables Your complete solution for high-end audio transmission, stereo, professional audio systems and home theater systems. Home Theater Sound Jacketed Cables Shielded: Twisted Bare Copper

More information

NewGeneration Cables. BELDENCable TM

NewGeneration Cables. BELDENCable TM NewGeneration Cables BELDENCable TM Table of Contents New Generation Cables Page No. Introduction 13.2 New Generation Cable Finder Guide 13.3 13.6 Security and Alarm Cable 13.7 13.26 Unshielded Multi-conductor:

More information

electronic wire pocket-picker edition 7/06 Low voltage electronic wire specialists

electronic wire pocket-picker edition 7/06 Low voltage electronic wire specialists electronic wire edition 7/06 pocket-picker Low voltage electronic wire specialists Contact Guide TOLL FREE Henry Coffey 800-37-3 Frank Conaty 888-3-897 Clark Feland 800-8-7137 Kathy Knoch 800-677-3 Jodi

More information

WIRE & CABLE. Wire & Cable... Wire Accessories...

WIRE & CABLE. Wire & Cable... Wire Accessories... Wire &... Wire Accessories... LINE CARD (9N) Arlington (GI) GRI (WG) Honeywell Cabling / Genesis (H2) ICC (Int l Conn & Corp) (RM) Remee (0E) W Box Technologies (WP) West Penn 1.800.233.6261 adiglobal.com/us

More information

Alarm & Security SOLUTIONS. Access Control Video Surveillance Fire Alarm Life Safety

Alarm & Security SOLUTIONS. Access Control Video Surveillance Fire Alarm Life Safety Alarm & Security SOLUTIONS Featuring Gepco Brand s for Lighting Control & Touch Panel Systems Access Control Video Surveillance Fire Alarm Life Safety Home Theater Burglar Alarms Data Communications Video

More information

SHIELD TYPE MULTICONDUCTOR MULTIPAIR

SHIELD TYPE MULTICONDUCTOR MULTIPAIR CABLE FINDER GUIDE CONDUCTOR SIZE 18 AWG METRIC 0,97mm 2 SHIELD TYPE MULTICONDUCTOR MULTIPAIR Materials Ratings No. of Alpha Page No. of Alpha Page Cable Type Insulation Jacket Temp. Voltage Conductors

More information

WIRE & CABLE. Wire & Cable... Wire Accessories...

WIRE & CABLE. Wire & Cable... Wire Accessories... Wire &... Wire Accessories... LINE CARD (9N) Arlington (GI) GRI (WG) Genesis (H2) ICC (Int l Conn & Corp) (RM) Remee (0E) W Box Technologies (WP) West Penn 1.800.233.6261 adiglobal.com/us New Vendor *

More information

Fire Alarm Systems ARTICLE. Introduction to Article 760 Fire Alarm Systems. Part I. General

Fire Alarm Systems ARTICLE. Introduction to Article 760 Fire Alarm Systems. Part I. General ARTICLE 760 Fire Alarm Systems Introduction to Article 760 Fire Alarm Systems Article 760 covers the installation of wiring and equipment for fire alarm systems, including all circuits controlled and powered

More information

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards Change History Date Description of Change Pages / Sections Modified Change Approver Initials 8/1/17 Updated section on Manufacturers 3 1. 6/15/16 Updated division section from 16120 to 26 05 00, - mgl44

More information

Genesis Series Cable THE POWER OF CHOICE. Cables for Silent Knight

Genesis Series Cable THE POWER OF CHOICE. Cables for Silent Knight Genesis Series Cable THE POWER OF CHOICE Cables for Silent Knight Cable for That! Genesis Series Cables for Silent Knight 5600 5700 5808 5820XL IFP-25 IFP-50 IFP-100 IFP-1000 IFP-2000 SK-5208 DIRECTORY

More information

Addressable NAC Output Module D327A

Addressable NAC Output Module D327A Installation Instructions Notice Addressable NAC Output Module D327A These instructions cover the installation of the D327A Addressable NAC Output Module in an analog system controlled by a Bosch D8024,

More information

Comtran s VITALink 2 Hour Fire Resistive CIC & CI Free Air Cables. Your trusted solution for fire safety

Comtran s VITALink 2 Hour Fire Resistive CIC & CI Free Air Cables. Your trusted solution for fire safety Comtran s VITALink 2 Hour Fire Resistive CIC & CI Free Air Cables Your trusted solution for fire safety When it comes to life and fire safety, trust the experts! Comtran has been a trusted source in the

More information

Quick Reference Applications Guide

Quick Reference Applications Guide Quick Reference Applications Guide General Cable manufactures the most comprehensive line of Carol Brand Electronic Cables available today for signal & data transmission, security, fire alarm & life safety,

More information

B. Configuration of system shall be through Schneider Electric in Homewood, Illinois (Jerry Lanfear ).

B. Configuration of system shall be through Schneider Electric in Homewood, Illinois (Jerry Lanfear ). SECTION 28 13 00 - ACCESS CONTROL PART I - GENERAL 1.1 SUMMARY A. This specification section describes the furnishing, installation, commissioning, and programming of a complete, turnkey, hardwired Andover

More information

Multi-Core Fire Resistant Cable

Multi-Core Fire Resistant Cable Fire Resistant Cables / Multi-Core Fire Resistant Cable Approved to UL 444, Zeta ZFP series cables have received UL approval for standard applications. Standards Alarm Cable Z UL 444 Approval CMH Rated

More information

CORFLEX. TYPE MC-HL & MV-105 or MC-HL OIL & GAS CABLES

CORFLEX. TYPE MC-HL & MV-105 or MC-HL OIL & GAS CABLES CORFLEX TYPE MC-HL & MV-105 or MC-HL OIL & GAS CABLES INDEX Instrumentation Cables - Pairs and Triads (0V*)... 2 - The Original MC-HL Technology In 1958 Canada Wire and Cable, which s now part of Nexans,

More information

Flame Retardant EP/CPE POWER, CONTROL & INSTRUMENTATION CABLES

Flame Retardant EP/CPE POWER, CONTROL & INSTRUMENTATION CABLES Flame Retardant EP/CPE POWER, CONTROL & INSTRUMENTATION CABLES 37-754 FLAME RETARDANT EP/CPE TYPE TC OR TC-ER POWER CABLE Two Five Conductor + Ground (Two, Three & Four Conductor) 600 V Rated 90 C Conductor*

More information

COMMON WORK RESULTS FOR ELECTRICAL: Basic Electrical Materials Methods

COMMON WORK RESULTS FOR ELECTRICAL: Basic Electrical Materials Methods 1. BASIC ELECTRICAL MATERIALS 1. All conduit and raceway must be 3/4" or larger. Exposed raceway in finished areas shall be in 700 or larger wiremold. Exception: runs to individual devices 10 or less,

More information

CORFLEX TYPE MC-HL POWER, CONTROL & INSTRUMENTATION CABLES

CORFLEX TYPE MC-HL POWER, CONTROL & INSTRUMENTATION CABLES CORFLEX TYPE MC-HL POWER, CONTROL & INSTRUMENTATION CABLES CORFLEX TYPE MC-HL POWER, CONTROL & INSTRUMENTATION CABLES INDEX Corflex MC-HL Instrumentation - Pairs and Triads (0V*)... 1 - CORFLEX Cables

More information

IDENTIFYING TRAY CABLES FOR YOUR NEXT INSTALLATION A WHITE PAPER

IDENTIFYING TRAY CABLES FOR YOUR NEXT INSTALLATION A WHITE PAPER IDENTIFYING TRAY CABLES FOR YOUR NEXT INSTALLATION A WHITE PAPER Published 3/23/2012 T hough rapidly increasing in popularity, tray cables are still a point of confusion for many. While the term tray cable

More information

Category 5 Premise Wire

Category 5 Premise Wire Category 5 Premise Wire engineered with you in mind Features Copper and Fiber Optic Cable Manufacturer U.S. Manufacturer State-of-the-Art Quality Labs ISO9001 Accredited Standard and Extended Warranties

More information

Second Revision No. 601 NFPA [ Section No [Excluding

Second Revision No. 601 NFPA [ Section No [Excluding Second Revision No. 601 NFPA 70 2015 [ Section No. 300.4 [Excluding any Sub Sections] ] Where subject to physical damage, conductors, raceways, and cables shall be protected. Informational Note: Minor

More information

Fort Rouge Leisure Centre Section HVAC Upgrades Phase 2 Page 1 of 5 Bid Opportunity No March 2013 FIRE ALARM SYSTEMS

Fort Rouge Leisure Centre Section HVAC Upgrades Phase 2 Page 1 of 5 Bid Opportunity No March 2013 FIRE ALARM SYSTEMS HVAC Upgrades Phase 2 Page 1 of 5 Part 1 General 1.1 SUMMARY.1 Section Includes:.1 Materials and installation for fire alarm systems upgrades..2 Audible signal devices..3 End-of-line devices..4 Sustainable

More information

INSTALLATION INSTRUCTIONS Model FH-2071-UM Enclosure

INSTALLATION INSTRUCTIONS Model FH-2071-UM Enclosure INSTALLATION INSTRUCTIONS Model FH-2071-UM Enclosure Enclosure INTRODUCTION The Model FH-2071-UM Enclosure from., used in Marine applications is robust and weather-resistant. Its durable design is customized

More information

IDP-Zone-6 Six Zone Interface Module

IDP-Zone-6 Six Zone Interface Module INSTALLATION AND MAINTENANCE INSTRUCTIONS IDP-Zone-6 Six Zone Interface Module BEFORE INSTALLING If the modules will be installed in an existing operational system, inform the operator and local authority

More information

Flexible Power Cable DLO

Flexible Power Cable DLO 37-119 Flexible Power Cable DLO 2000 Volts 90 C Diesel Locomotive Cable Limited Smoke (Sizes 2/0 and higher) EP/CPE RHH, RHW-2 Flexible-stranded, tin-coated annealed copper Flame retardant, oil and sunlight

More information

Brand Portable Power Cord & Control Cable Solutions

Brand Portable Power Cord & Control Cable Solutions Carol Brand Portable Power Cord & Control Cable Solutions for the Entertainment Market General Cable s Carol Brand portable power cord and control cable solutions are manufactured for use in the entertainment

More information

PHOTOVOLTAIC CABLES. Photovoltaic Cable 2000V/1500V Photovoltaic Cable 2000V/1000V

PHOTOVOLTAIC CABLES. Photovoltaic Cable 2000V/1500V Photovoltaic Cable 2000V/1000V PHOTOVOLTAIC CABLES PHOTOVOLTAIC CABLES INDEX n AmerSol Dual-Certified (UL / ETL) Photovoltaic Cable 2000V/1500V....................... 2-3 n AmerSol Dual-Certified (UL / ETL) Photovoltaic Cable 2000V/1000V.......................

More information

OUR SOLUTION: YOUR CABLE. PRODUCTION OVERVIEW

OUR SOLUTION: YOUR CABLE. PRODUCTION OVERVIEW OUR SOLUTION: YOUR CABLE. PRODUCTION OVERVIEW Our expertise Our expertise Company MUCKENHAUPT & NUSSELT is a cable production company in Wuppertal, which has been successful in the market since 1926 and,

More information

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 28 ELEC. SAFETY & SECURITY SECTION CONDUCTORS AND CABLES FOR ELECTRONIC SAFETY AND SECURITY

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 28 ELEC. SAFETY & SECURITY SECTION CONDUCTORS AND CABLES FOR ELECTRONIC SAFETY AND SECURITY SECTION 280513 - CONDUCTORS AND CABLES FOR ELECTRONIC SAFETY AND SECURITY PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Coaxial cabling. 2. RS-232 cabling. 3. RS-485 cabling. 4. Low-voltage control

More information

Sound and Paging Systems

Sound and Paging Systems 9 Section 9 Belden........................................................................ 9.1 9.3 Generic........................................................................ 9.4 9.7 Bogen.........................................................................

More information

Amerex Clean Agent System with FM200. Potential Applications: System Coverage Overview: Approvals and Standards:

Amerex Clean Agent System with FM200. Potential Applications: System Coverage Overview: Approvals and Standards: Amerex Clean Agent System with FM200 Utilizing the industry recognized FM-200 suppression agent, Amerex has developed an affordable pre-engineered clean agent fi re suppression system to protect areas

More information

Fire alarm system specification for multiple tenant retail buildings

Fire alarm system specification for multiple tenant retail buildings Date: June 20, 2011 Project name: Baederwood Shopping Center Multiple Tenant Buildings B & C City/ State: Abington, PA Landlord s Vendor Contact: Dan Morrin Jr., NECCO Security Phone: (215)638-7999 Email:

More information

CIR CRUSH & IMPACT RESISTANT OIL & GAS CABLES

CIR CRUSH & IMPACT RESISTANT OIL & GAS CABLES CIR CRUSH & IMPACT RESISTANT OIL & GAS CABLES Gexol CIR Crush and Impact Resistant Without External Armoring Passes the same stringent crush and impact testing required by UL 2225 for Type MC-HL Index

More information

Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design.

Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design. ADDISON Flame Retardant RG59 B/U Coaxial cables Plain copper wire braid PE Solid Bare Copper PVC Outer Sheath APPLICATION The cables are designed for CCTV, security, smoke detection and evacuation monitoring

More information

Print Specification. Publication. Instructions. Specific requirements. General requirements

Print Specification. Publication. Instructions. Specific requirements. General requirements Print Specification Publication GSA-CC1 Single Input Signal Module Installation Sheet P/N P-047550-1802-EN REV 04 ISS 23JUN15 Instructions This page is the print specification for the publication. It is

More information

SIGA-CC1 Single Input Signal Module Installation Sheet

SIGA-CC1 Single Input Signal Module Installation Sheet SIGA-CC1 Single Input Signal Module Installation Sheet Personality codes Use the personality codes described below to configure the SIGA-CC1 module. See Table 1 for listing information Table 1: Personality

More information

Honeywell Cable. We ve got a cable for that!

Honeywell Cable. We ve got a cable for that! Honeywell Cable We ve got a cable for that! We ve Got a Cable for That! Cables for Intrusion Cables for Video Cables for Access Control Cables for Audio/Video Cables for Fire Cables for Network Cables

More information

SECTION INTRUSION DETECTION A. SCOPE OF WORK FOR DESIGNER AND CONSULTANTS

SECTION INTRUSION DETECTION A. SCOPE OF WORK FOR DESIGNER AND CONSULTANTS INTRUSION DETECTION SECTION 281600 PART 1 GENERAL 1.1. SCOPE OF WORK A. SCOPE OF WORK FOR DESIGNER AND CONSULTANTS See paragraph 1.1 of Section 280500 Common Work Results for Electronic Safety and Security

More information

MMF Six Zone Interface Module

MMF Six Zone Interface Module Installation and Maintenance Instructions I56-900-005 MMF-0-6 Six Zone Interface Module SPECIFICATIONS Normal Operating Voltage: 5- VDC Stand-By Current: ma Alarm Current: 40 ma (assumes all six LEDs solid

More information

EMS510 Electrical Wiring Guide Volume 2, Rev 1.4

EMS510 Electrical Wiring Guide Volume 2, Rev 1.4 EMS510 Electrical Wiring Guide Volume 2, Rev 1.4 Prepared by Michael L. Kominske Environmental Monitor Service Inc. PO Box 4340 Yalesville, CT 06492 Phone 203.935.0102 Fax 203.634.6663 Email: sales@emsct.com

More information

5. Identification products.

5. Identification products. Essex County College - West Essex Campus Addition And Renovations dib # 54292 / 11-14 [SECTION 260523- CONTROL-VOLTAGE ELECTRICAL POWER CABLES PART 1- GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general

More information

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Union County Vocational - Technical Schools Scotch Plains, New Jersey SECTION 220533 - HEAT TRACING FOR PLUMBING PIPING PART 1 - GENERAL 1.1 SUMMARY A. This Section includes plumbing piping heat tracing for freeze prevention, domestic hot-water-temperature maintenance, and

More information

SECTION RADIANT-HEATING ELECTRIC CABLES PART 1 - GENERAL 1.1 SECTIONS INCLUDES

SECTION RADIANT-HEATING ELECTRIC CABLES PART 1 - GENERAL 1.1 SECTIONS INCLUDES SECTION 238313 - RADIANT-HEATING ELECTRIC CABLES PART 1 - GENERAL 1.1 SECTIONS INCLUDES A. Low-voltage Electric Snow and ice heating elements "under" finished roof materials (shingles or metal), gutters,

More information

CIR CRUSH & IMPACT RESISTANT ARCTIC GRADE OIL & GAS CABLES

CIR CRUSH & IMPACT RESISTANT ARCTIC GRADE OIL & GAS CABLES CIR CRUSH & IMPACT RESISTANT ARCTIC GRADE OIL & GAS CABLES Gexol CIR ARCTIC GRADE (AG) Crush and Impact Resistant Without External Armoring Passes the same stringent crush and impact testing required by

More information

CIR AG Power Cables. CIR AG Control Cable. CIR Type VFD Cable. CIR AG Ratings & Approvals. n UL Listed as Type TC-ER n UL Listed as TC-ER-HL (E123629)

CIR AG Power Cables. CIR AG Control Cable. CIR Type VFD Cable. CIR AG Ratings & Approvals. n UL Listed as Type TC-ER n UL Listed as TC-ER-HL (E123629) Gexol CIR ARCTIC GRADE (AG) Crush and Impact Resistant Without External Armoring Passes the same stringent crush and impact testing required by UL 2225 for Type MC-HL n Shortest Lead Times Standard 8-10

More information

Genesis Cable Audio/Video Product Catalog DELIVERING THE ULTIMATE AUDIO/VIDEO EXPERIENCE

Genesis Cable Audio/Video Product Catalog DELIVERING THE ULTIMATE AUDIO/VIDEO EXPERIENCE Genesis Cable Audio/Video Product Catalog DELIVERING THE ULTIMATE AUDIO/VIDEO EXPERIENCE Bring It Home Our wide range of application-specific cable ensures optimal performance in residential or commercial

More information

Belden Infinity C-TC+ Cables for Extreme Flexing

Belden Infinity C-TC+ Cables for Extreme Flexing Product Bulletin PB 0 Belden Infinity Cables These highly flexible control, power, video and data cables handle the rigorous speeds and near-constant motion of C-track systems, robots, pick-and-place machines,

More information

SECTION CONDUCTORS AND CABLES FOR ELECTRONIC SAFETY AND SECURITY

SECTION CONDUCTORS AND CABLES FOR ELECTRONIC SAFETY AND SECURITY SECTION 280513 CONDUCTORS AND CABLES FOR ELECTRONIC SAFETY AND SECURITY PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions

More information

Installation Guide. Tracer ZN523 Zone Controller BAS-SVN003-E4

Installation Guide. Tracer ZN523 Zone Controller BAS-SVN003-E4 Installation Guide Tracer ZN523 Zone Controller Contents Introduction About this manual 3 Controller description 4 Typical network architecture 5 Hardware inspection 6 Mounting and wiring ZN523 mounting

More information

MEDIUM, LOW AND CONTROL VOLTAGE CABLES

MEDIUM, LOW AND CONTROL VOLTAGE CABLES Related Sections U-M Design Guideline Sections: 260800 - Electrical Acceptance Tests Products Medium Voltage Primary Cables Primary power distribution cable shall be single conductor stranded copper, with

More information

- 4 12VDC or 24VDC VDC or 24VDC - Eight (8) Fused Outputs - Eight (8) PTC Outputs. Installing Company: Service Rep.

- 4 12VDC or 24VDC VDC or 24VDC - Eight (8) Fused Outputs - Eight (8) PTC Outputs. Installing Company: Service Rep. 140 58th St. Brooklyn, NY Power Supply/Chargers Installation Guide Models Include: eflow4n/eflow4nx - 4 amp @ 12VDC or 24VDC eflow4n8/eflow4nx8 eflow4n8d/eflow4nx8d - 4 amp @ 12VDC or 24VDC - 4 amp @ 12VDC

More information

SAS Security and Alarm Safety Cables

SAS Security and Alarm Safety Cables CABLES Security and Alarm Safety Cables Security and Alarm Safety Cables LOW SMOKE ZERO HALOGEN The right range of cables for modern building installations e-catalogue 203/4 Flexible solutions for commercial,

More information

BELDEN LOW VOLTAGE COPPER CABLE PLENUM RATED

BELDEN LOW VOLTAGE COPPER CABLE PLENUM RATED ENVIRONMENTAL PRODUCT DECLARATION BELDEN LOW VOLTAGE COPPER CABLE PLENUM RATED At Belden, our core values include customers defining our success, and continuously improving. These are rooted in our culture

More information

AFC Cable Systems: the Cable Industry Leader for Over 80 Years

AFC Cable Systems: the Cable Industry Leader for Over 80 Years AFC Cable Systems: the Cable Industry Leader for Over 80 Years AFC Cable Systems, Inc, is proud to announce the launch of two new Type MC cables, MC-Quik and MC-Stat. These two new cables offer the fastest

More information

16.34 Multiplex Fire Alarm System Construction Standards Page 1 of 5

16.34 Multiplex Fire Alarm System Construction Standards Page 1 of 5 Construction Standards Page 1 of 5.1 General Description.1 The University requires that all new fire alarm system control panel, components, and devices, as required for the project, be Secutron 2900 Series

More information

SECTION CONDUCTORS AND CABLES FOR ELECTRONIC SAFETY AND SECURITY

SECTION CONDUCTORS AND CABLES FOR ELECTRONIC SAFETY AND SECURITY PART 1 - GENERAL 1.1 DESCRIPTION SECTION 28 05 13 CONDUCTORS AND CABLES FOR ELECTRONIC SAFETY AND SECURITY SPEC WRITER NOTE: Use this section only for NCA projects. Delete between // // if not applicable

More information

(800) 292- omnicable.com CABLE ACCESSORIES GUIDE

(800) 292- omnicable.com CABLE ACCESSORIES GUIDE CABLE ACCESSORIES GUIDE SECTION PAGES Heat-Shrink Joints 1 Cold Shrinkable Joints 2 Heat-Shrink Terminations 3 Tool Free Terminations 4 Modification Kits for 3-Conductor Cable 5 MV Splice & Termination

More information

Caledonian Flame Retardant Coaxial Cables

Caledonian Flame Retardant Coaxial Cables Caledonian Flame Retardant Coaxial Cables www.caledonian-cables.co.uk www.addison-cables.com Flame Retardant RG59 Coaxial cables LSZH Outer Sheath Tinned Copper Braid Aluminium+polyester/Aluminium Tape

More information

Thermocouple Cable TRANSMITTING, SENSING, MEASURING

Thermocouple Cable TRANSMITTING, SENSING, MEASURING Thermocouple Cable TRANSMITTING, SENSING, MEASURING Our Commitment Our commitment to our customers is simple - we deliver even when others can t. As one of Canada s largest wire, cable and data communication

More information

Heat Tracing Sales Mt. Airy, Maryland Heating Cable. Cut to Length in Field. Description

Heat Tracing Sales Mt. Airy, Maryland Heating Cable. Cut to Length in Field. Description Self-Regulating Protection D E C B A Self-Regulating, Energy Efficient Designed for Protection Max. Exposure Temp. 185 F (Power Off) Cost Effective for Commercial Construction Protection Applications Protection

More information

Wire and Cable. For more information on these Tyco Electronics products, visit the following website:

Wire and Cable. For more information on these Tyco Electronics products, visit the following website: 26 Wire and Cable Raychem High Performance Wire and Cable....26-2 to 26-4 Madison Cable Products...................26-5 to 26-7 Reference the following cables in Section 15 of this catalog: Premises Networking

More information

POINT OBSTRUCTION CONTROLLER POC TOUCHSCREEN CONTROLLERS

POINT OBSTRUCTION CONTROLLER POC TOUCHSCREEN CONTROLLERS POINT OBSTRUCTION CONTROLLER Compliances: FAA Advisory Circular 70/7460-1L ICAO Annex 14, Volume I, Chapter 6 The controller provides the control and monitoring functions for an LED red obstruction lighting

More information

Thermal Devices, Inc. Mount Airy, Maryland USA Heating Cable. Cut to Length in Field

Thermal Devices, Inc. Mount Airy, Maryland USA   Heating Cable. Cut to Length in Field Thermal Devices, Inc. Mount Airy, Maryland UA www.thermaldevices.com RF elf-regulating Freeze Protection D E C B A Max. Exposure Temp. 185 F (Power Off) Cost Effective for Commercial Construction Freeze

More information

Belden. Intrusion Detection. Intrusion Detection. Multiconductor Shielded Plenum/Alarm Cable

Belden. Intrusion Detection. Intrusion Detection. Multiconductor Shielded Plenum/Alarm Cable Belden./Cables;Intrusion/14261 Multiconductor Shielded Plenum/Alarm Cable BELDEN Power limited circuit and communications cable for plenum applications. For use in remote control, signaling, security systems,

More information

CSI Master Format 2004 Guide Specification for: Flow Maintenance of Above Ground Greasy Waste Disposal Lines

CSI Master Format 2004 Guide Specification for: Flow Maintenance of Above Ground Greasy Waste Disposal Lines CSI Master Format 2004 Guide Specification for: Flow Maintenance of Above Ground Greasy Waste Disposal Lines System for flow maintenance of above ground greasy waste disposal lines with line sensing control,

More information

CSI Master Format 2004 Guide Specification for: Flow Maintenance of Aboveground Fuel Oil Lines

CSI Master Format 2004 Guide Specification for: Flow Maintenance of Aboveground Fuel Oil Lines CSI Master Format 2004 Guide Specification for: Flow Maintenance of Aboveground Fuel Oil Lines System for flow maintenance of aboveground fuel oil lines with Proportional Ambient Sensing Control (PASC),

More information

CZ-6A Six Zone Interface Module

CZ-6A Six Zone Interface Module INSTALLATION AND MAINTENANCE INSTRUCTIONS CZ-6A Six Zone Interface Module 658 Kitimat Rd. Unit #6 Mississauga, Ontario L5N T5-800-SENSOR, FAX: 905-8-077 www.systemsensor.ca SPECIFICATIONS Normal Operating

More information

Comtran Cable. Hub-LINK Cables for Transit Applications

Comtran Cable. Hub-LINK Cables for Transit Applications Comtran Cable Hub-LINK Cables for Transit Applications Overview Hub-LINK rail transit cables are designed to resist the rugged conditions of the underground and at-grade environments, including: Temperature

More information

SP-1000X. Panic Device Power Controller Installation Guide. Rev

SP-1000X. Panic Device Power Controller Installation Guide. Rev TM SP-1000X Panic Device Power Controller Installation Guide Rev. 120213 Overview: SP-1000X will operate up to two (2) 24VDC panic hardware devices simultaneously. It is designed to handle the high current

More information

GE Total Lighting Control

GE Total Lighting Control GE Total Lighting Control ProSys Lighting Control System Catalog Number RINTERxxxPS(P) ProSys Lighting Control System Relay Panels RINTER2424PSP 24-Relay Interior shown with RTUB24 DESCRIPTION The ProSys

More information

DOOR MONITORING/DURESS SYSTEM

DOOR MONITORING/DURESS SYSTEM SECTION PART 1 - GENERAL 1.1 RELATED SECTIONS A. Comply with the requirements of Section 27 05 00 Common Work Results for Communications. 1.2 DEFINITIONS A. Not used. 1.3 DESCRIPTION OF SYSTEM: A. Provide

More information

SECTION RADIANT-HEATING ELECTRIC CABLES / MATS

SECTION RADIANT-HEATING ELECTRIC CABLES / MATS SECTION 238313- RADIANT-HEATING ELECTRIC CABLES / MATS PART 1 - GENERAL 1.1 SECTION INCLUDES A. Electric radiant snow melting mats or cables embedded in concrete or asphalt slabs, or embedded under brick

More information

SUBJECT: NFPA 70 Second Draft TC Ballot Final Results (A2016)

SUBJECT: NFPA 70 Second Draft TC Ballot Final Results (A2016) National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org TO: NEC Code-Making Panel 3 FROM: Kimberly Shea, Administrator, Technical

More information

SLATE. Base Module INSTALLATION INSTRUCTIONS R8001A1001

SLATE. Base Module INSTALLATION INSTRUCTIONS R8001A1001 SLATE Base Module R8001A1001 INSTALLATION INSTRUCTIONS Scan for more information Application SLATE brings configurable safety and programmable logic together into one single platform. The platform can

More information

Keywords: VEWFD; Smoke detection; Smoke production; In-situ testing.

Keywords: VEWFD; Smoke detection; Smoke production; In-situ testing. In-Situ Smoke Generation for Testing Very Early Warning Fire Detection (VEWFD) Joshua Dinaburg, Benjamin Gaudet Jensen Hughes, Baltimore, MD, USA Abstract In-situ smoke sensitivity testing in an operational

More information

Fire Alarm Cables WEST PENN WIRE

Fire Alarm Cables WEST PENN WIRE Fire Alarm Cables Life. Safety. Fire alarm systems serve as life lines to safe and secure buildings. As one of the original manufacturers of fire alarm cable, West Penn Wire knows proper cable selection

More information

HOME LOAD MANAGER INSTALLATION MANUAL Hardware Revision 1.4 & Higher

HOME LOAD MANAGER INSTALLATION MANUAL Hardware Revision 1.4 & Higher Micro Control Systems APPLICATION NOTE APP-006 5400-1 Division Drive Ft. Myers, FL 33905 USA (941)-694-0089 Fax (941) 694-0031 HOME LOAD MANAGER INSTALLATION MANUAL Hardware Revision 1.4 & Higher Revision

More information

SECTION FIRE ALARM

SECTION FIRE ALARM SECTION 16740 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections, apply to this

More information

SC-6 Six Supervised Control Module

SC-6 Six Supervised Control Module INSTALLATION AND MAINTENANCE INSTRUCTIONS SC-6 Six Supervised Control Module SPECIFICATIONS Normal Operating Voltage: Stand-By Current: Alarm Current: Temperature Range: Humidity: Dimensions: Accessories:

More information

System Accessories, LCD Annunciators

System Accessories, LCD Annunciators System Accessories, LCD Annunciators UL, ULC Approved* A4606 Series Color Touchscreen LCD Annunciators for 4007ES Fire Alarm Control Panels Features Fig 1: A4606-9202 LCD Annunciator with Red Trim Fig

More information

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017 SECTION 26 0519 LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions

More information

FreezGard. Self-regulating crankcase heater. Product Overview

FreezGard. Self-regulating crankcase heater. Product Overview Self-regulating crankcase heater Product Overview When compressors operate in cold areas, refrigerant can migrate into the crankcase oil whenever the compressor is not running. On start-up, this can cause

More information

CATEGORY 6A FTP RJ45 SOLUTION

CATEGORY 6A FTP RJ45 SOLUTION CATEGORY 6A FTP RJ45 SOLUTION Clipsal titanium Patch Cord Clipsal titanium LSZH Patch Cord Clipsal titanium Keystone Jacks Clipsal titanium Modular Jacks Clipsal titanium Patch Panels Clipsal titanium

More information

SolderSleeve Shield Terminators

SolderSleeve Shield Terminators SolderSleeve Shield Terminators Product Facts Transparent insulation sleeve provides encapsulation, inspectability, strain relief, and insulation Prefluxed solder preform provides a controlled soldering

More information

MODEL SST 2 40 FREEZE PROTECTION THERMOSTAT MODEL SST FIXED SET POINT THERMOSTAT. Installation and Operation Manual

MODEL SST 2 40 FREEZE PROTECTION THERMOSTAT MODEL SST FIXED SET POINT THERMOSTAT. Installation and Operation Manual Electronic Thermostats with Ground Fault Equipment Protection MODEL SST 2 40 FREEZE PROTECTION THERMOSTAT P/N 22744 MANUAL We Manage Heat MODEL SST 2 175 FIXED SET POINT THERMOSTAT P/N 23708 Installation

More information

CSI Master Format 2004 Guide Specification for: Freezer Frost Heave Prevention (Mineral Insulated)

CSI Master Format 2004 Guide Specification for: Freezer Frost Heave Prevention (Mineral Insulated) CSI Master Format 2004 Guide Specification for: Freezer Frost Heave Prevention (Mineral Insulated) System for preventing frost heave in freezers, cold rooms and ice arenas with temperature control, monitoring,

More information

Texas Based UL Alarm System Monitoring. Alarm System Monitoring Up to 128 zones $34.95 per month 25.00% $26.22

Texas Based UL Alarm System Monitoring. Alarm System Monitoring Up to 128 zones $34.95 per month 25.00% $26.22 Specification MAINTENANCE & MONITORING Texas Based UL Alarm System Monitoring Requires a phone line for communications, less options available and cell back up available Alarm System Monitoring Up to 128

More information

F1202 TRACE HEATING. Road & Ramp

F1202 TRACE HEATING. Road & Ramp Trace Heating Specialists Road & Ramp ROAD & RAMP HEATING ESH Trace Heating Ltd provide a comprehensive range of products to prevent the settlement of snow and formation of ice on roads, ramps and stairs.

More information

CAT5E DIRECT BURIAL (FLOODED CORE) 24AWG, UTP, 4 PAIR, SOLID 1000 PULL BOX /CMXF

CAT5E DIRECT BURIAL (FLOODED CORE) 24AWG, UTP, 4 PAIR, SOLID 1000 PULL BOX /CMXF POST CAT5E DIRECT BURIAL (FLOODED CORE) 24AWG, UTP, 4 PAIR, SOLID 1000 PULL BOX PART NUMBER: 059-485/CMXF 1 APPROVALS: MARKETING DATE: THE INFORMATION CONTAINED IN THIS DOCUMENT IS PROPRIETARY TO VERTICAL

More information

NEC 2017 Changes and Their Effect Upon the ICT Industry

NEC 2017 Changes and Their Effect Upon the ICT Industry NEC 2017 Changes and Their Effect Upon the ICT Industry Today s Presenters John Kacperski, RCDD, OSP, CDT Chair of BICSI Standards BICSI Representative on NFPA 70-CMP 16 Richard S. Anderson, RCDD, CDT,

More information

Booster Power Supply Manual

Booster Power Supply Manual Supply Manual DEVELOPED BY COPYRIGHT NOTICE General Signal Building Systems Corporation 6411 Parkland Drive Sarasota, FL 34243 (941) 739-4300 Copyright 1999 General Signal Building Systems Corporation

More information