electronic wire pocket-picker edition 7/06 Low voltage electronic wire specialists

Size: px
Start display at page:

Download "electronic wire pocket-picker edition 7/06 Low voltage electronic wire specialists"

Transcription

1 electronic wire edition 7/06 pocket-picker Low voltage electronic wire specialists

2 Contact Guide TOLL FREE Henry Coffey Frank Conaty Clark Feland Kathy Knoch Jodi Lauren Krysta McCrea Richard Moon Dan Pritchard Brad Schneider Roxanne Tobia Linda Todaro

3 electronic wire edition 10/0 pocket-picker

4 APPLICATION INDEX USE SECTION PAGE VDC Power (Distinguisher) Fire Alarm Systems 3 Annunciator Comm. (Distinguisher) Fire Alarm Systems 3 Annunciator Power (Distinguisher) Fire Alarm Systems 3 Category 3, 5e & 6 LAN, Data, Networking Solutions 9 CATV Coaxial Cables 1 CCTV Coaxial Cables 1 Contacts Sound & Security Systems 5 Data Comm. SLC (Distinguisher) Fire Alarm Systems 3 Data Comm. SLC Fire Alarm Systems 3 Data Sound & Security Systems 5 Fire Phone Fire Alarm Systems 3 Glass Break Sensors Sound & Security Systems 5 Heat Detector Fire Alarm Systems 3 Heater Power Coaxial Cables 1 Horn (Distinguisher) Fire Alarm Systems 3 Horn Fire Alarm Systems 3 Intercom Sound & Security Systems 5 Keypad Fire Alarm Systems 3 Keypad Sound & Security Systems 5 Lock Power Sound & Security Systems 5 Microphone Sound & Security Systems 5 Motion Detectors Sound & Security Systems 5 Networking LAN, Data, Networking Solutions 9 Paging / Sound Sound & Security Systems 5 Pan / Tilt / Zoom Coaxial Cables 1 Panic Station Fire Alarm Systems 3 Patch Cables Coaxial Cables 1 Power Sound & Security Systems 5 Power (camera) Coaxial Cables 1 Reader Cable Sound & Security Systems 5 Request To Exit Sound & Security Systems 5 Smoke Detector Fire Alarm Systems 3 Sounder Base Fire Alarm Systems 3 Sounder Cable Sound & Security Systems 5 Speakers (Distinguisher) Fire Alarm Systems 3 Speakers Sound & Security Systems 5 Strobe (Distinguisher) Fire Alarm Systems 3 Strobe Fire Alarm Systems 3 Telephone LAN, Data, Networking Solutions 9 Thermostat Thermostat 59 Video Signal Coaxial Cables 1 Water Sensors Sound & Security Systems 5

5 TABLE OF CONTENTS Sound & Security Systems 5 Multi-Conductor, Unshielded, Non-Plenum 7-9 Multi-Conductor, Unshielded, Plenum Multi-Conductor, Shielded, Non-Plenum 10-1 Multi-Conductor, Shielded, Plenum Multi-Pair, Individually Shielded, Non-Plenum 13 Multi-Pair, Individually Shielded, Plenum 19 Multi-Pair, Shielded + Unshielded, Non-Plenum 1 Multi-Pair, Shielded + Unshielded, Plenum 0 Composite Cable, Plenum 1- Fire Alarm SystemS 3 Circuit Integrity (CI), Non-Plenum 36 Distinguisher Circuit Tracer 3-3 Metal Clad 38-0 Multi-Conductor, Unshielded, Non-Plenum 6-7 Multi-Conductor, Unshielded, Plenum 9 Multi-Conductor, Shielded, Non-Plenum 7 Multi-Conductor, Shielded, Plenum 30 Mid-Capacitance, Shielded, Non-Plenum 8 Mid-Capacitance, Shielded, Plenum 31 Non-Twisted, Plenum 37 Sounder Base, Plenum 3 TFN / THHN Non-Plenum 5 Zip Wire, Non-Plenum 37 Coaxial Cable 1 CATV Non-Plenum 3 CATVP Plenum 6 CATV RGB Composite Video (RGBHV) 5 CCTV Non-Plenum CCTV Plenum 7 Patch Cables 8 Outdoor 71 LAN, Data & Networking Solutions 9 Category 3 UTP, Non-Plenum 51 Category 3 UTP, Plenum 5 Category 5e UTP, Non-Plenum 53 Category 5e STP, Non-Plenum 53 Category 5e UTP, Plenum 5 Category 5e STP, Plenum 5 Category 5e Powersum, Plenum 55 Category 5e Direct Burial 75 Category 5e Patch Cables Category 6 UTP, Non-Plenum & Plenum 58 Thermostat CabLE 59 Multi-Conductor, Unshielded, Plenum 61 Outdoor Cable 63 Aerial or Direct Burial Multi-Conductor, Unshielded Multi-Conductor, Overall Shielded 68 Multi-Pair, Overall Shielded 69 Aerial or Conduit Burial Multi-Pair, Individually Shielded 70 Coaxial 71 Category 5 7 Messenger Cable 73 Fiber Optic CabLE 75 Indoor Plenum 80 Indoor / Outdoor Riser 81 Indoor / Outdoor Plenum 8 Self-Supporting Aerial 83 ADSS Hardware & Accessories 8 Connectors & Accessories 85 Technical Information 87 NEC Made Easy Copper Wire 9-93 Installation Calculations 9-96 Conversion Tables 97 Custom CabLES 99 Electronic Cable Design 100 Parameter Punch List 101 Cross References 103 Belden Cross Reference West Penn Cross Reference Quick Reference

6

7 SOUND & SECURITY SYSTEMS Paige sound and security cables are designed for a wide range of applications in low voltage sound and security systems. They carry the following listings in common. 75 C Temperature rated 300 volt UL Listed and Canadian UL Listed Meet NEC Articles 800 and 75 Most are dual listed to also meet NEC Articles 760 permitting cross application in fire alarm systems Dual NEC / UL Listings for cables in this section: Gauge Sizes Non-plenum Non-plenum Riser Plenum AWG 16 AWG CM/FPL CMR/FPLR CMP/FPLP 1 AWG 1 AWG CL3/FPL CL3R/FPLR CL3P/FPLP For additional information on NEC / UL see p in the technical section. Additional features of cables in this section: Twisted conductors for reduced cross-talk ASTM bare copper conductors Premium grade PVC for improved strength and flexibility When shielded, corrosion resistant tinned copper drain wires are used Color-coded conductors 5

8 SOUND & SECURITY SYSTEMS CONDUCTOR COLOR CHART Color Code 1 1 Black Red 3 White Green 5 Brown 6 Blue 7 Orange 8 Yellow 9 Purple 10 Gray 11 Pink 1 Tan 13 White / Black 1 White / Red 15 White / Green 16 White / Orange 17 White / Blue 18 White / Brown 19 White / Yellow 0 White / Purple 1 White / Gray Black / Red 3 Black / Green Black / Yellow 5 Black / Blue 6 Black / Brown 7 Black / Orange 8 Black / Gray 9 Black / Purple 30 Red / Green Color Code Black Red Brown Blue Orange Yellow Purple Green Red / Black Red / White Red / Green Red / Blue Color Code 8 Pair # 1st/nd 1 Black / Red Black / White 3 Black / Green Conductor Colors BE Beige PK Pink BK Black PR Purple BL Blue RE Red BR Brown VI Violet GN Green WH White GR Gray YW Yellow OR Orange Pair # Color Code 1st Conductor Black / Red Black / White Black / Green Black / Blue Black / Yellow Black / Brown Black / Orange Red / White Red / Green Red / Blue Red / Yellow Red / Brown Red / Orange Green / White Green / Blue Green / Yellow Green / Brown Green / Orange White / Blue White / Yellow White / Brown White / Orange Blue / Yellow Blue / Brown Blue / Orange Brown / Yellow Brown / Orange nd Conductor Red White Green Blue Yellow Brown Orange White Green Blue Yellow Brown Orange White Blue Yellow Brown Orange Blue Yellow Brown Orange Yellow Brown Orange Yellow Orange 6

9 SOUND & SECURITY SYSTEMS NON-PLENUM CMR ASTM Bare Copper High Grade PVC Insulation Twisted/Cabled Conductors Riser Rated Gray PVC Jacket MULTI-CONDUCTOR UNSHIELDED AWG & STRANDING NO. OF COND. NOM POSSIBLE USE & APPLICATIONS 5606Axx 5607Axx 5665AGR 5608Axx* Solid 7 x 30 7 x 30 Solid Access Control Security Devices Sound & Audio Intercom Paging Background Music 5609Axx 7 x AGR Solid AGR 7 x AGR Solid AGR 7 x AGR Solid AGR 7 x AGR Solid AGR 7 x AGR 0 7 x AGR 0 7 x AGR 0 7 x AGR 0 7 x Conductor color code 1. Chart on page 6. Non-Stock, Call for Availability. *Conductor colors are RE, GN, YW, BK and have a random twist. 7

10 SOUND & SECURITY SYSTEMS NON-PLENUM CMR ASTM Bare Copper High Grade PVC Insulation Twisted/Cabled Conductors Riser Rated Gray PVC Jacket MULTI-CONDUCTOR UNSHIELDED AWG & STRANDING NO. OF COND. NOM POSSIBLE USE & APPLICATIONS 59AGR 5703Axx 560AGR 5668AGR 0 7 x 8 18 Solid 18 7 x x Access Control Security Devices Sound & Audio Intercom Paging Background Music 570Axx** 18 Solid AGR 18 7 x GR 18 7 x AGR 18 7 x AGR 18 7 x AGR 18 7 x AGR 18 7 x AGR x AGR x AGR x 9.36 Conductor color code 1. Chart on page page 6. Non-Stock, Call for Availability. **Conductor color code 8

11 SOUND & SECURITY SYSTEMS NON-PLENUM CL3R ASTM Bare Copper High Grade PVC Insulation Twisted/Cabled Conductors Riser Rated Gray PVC Jacket MULTI-CONDUCTOR UNSHIELDED AWG & STRANDING NO. OF COND. NOM POSSIBLE USE & APPLICATIONS 567AGR 5671GR 5675AGR 5676AGR 1 19 x x x x Access Control Security Devices Sound & Audio Intercom Paging Background Music 56761GR 1 19 x Conductor color code 1. Chart on page page 6. Non-Stock, Call for Availability. 9

12 SOUND & SECURITY SYSTEMS NON-PLENUM MULTI-CONDUCTOR, OVERALL SHIELDED CMR ASTM Bare Copper High Grade PVC Insulation Aluminum Polyester Foil Shield with drain Twisted/Cabled Conductors Riser Rated Gray PVC Jacket AWG & STRANDING NO. OF COND. NOM POSSIBLE USE & APPLICATIONS 5677AGR 560AGR 5678AGR 561AGR Solid 7 x 30 7 x 30 7 x Access Control Security Devices Sound & Audio Intercom Paging Background Musi 56AGR 7 x AGR 7 x AGR 7 x AGR 7 x AGR 0 Solid AGR 0 7 x AGR 0 7 x AGR 18 Solid AGR 18 7 x AGR 18 7 x AGR 18 7 x AGR 18 7 x AGR 18 7 x Conductor color code 1. Chart on page page 6. * Non-Stock, Call for Availability. 10

13 SOUND & SECURITY SYSTEMS NON-PLENUM MULTI-CONDUCTOR OVERALL SHIELDED CMR ASTM Bare Copper High Grade PVC Insulation Aluminum Polyester Foil Shield with drain Twisted/Cabled Conductors Riser Rated Gray PVC Jacket AWG & STRANDING NO. OF COND. NOM POSSIBLE USE & APPLICATIONS 567AGR 597AGR 5686AGR x x x Access Control Security Devices Sound & Audio Intercom Paging Background Music CL3R 568AGR 5687AGR 1 19 x x Access Control Security Devices Sound & Audio Intercom Paging Background Music Conductor color code 1. Chart on page page 6. Non-Stock, Call for Availability. 11

14 SOUND & SECURITY SYSTEMS NON-PLENUM Data and Communications Grade Multi-Conductor, Overall Shielded Low & Mid Capacitance CM ASTM Bare or Tinned Copper Polypropylene or Polyethylene Insulation Aluminum Polyester Foil Shield with drain Twisted/Cabled Conductors Gray PVC Jacket AWG & STRANDING NO. OF COND. NOM CAPACITANCE 56001AGR 7 x pf / ft 560GR 7 x 30 TC pf / ft 599AGR 18 7 x pf / FT Microphone Cable, Mini-Audio Multi-Conductor, Overall Shielded Mid-Capacitance 5601BK 7 x 30 TC pf / ft Conductor color code 1. Chart on page page 6. * Non-Stock, Call for Availability. 1

15 SOUND & SECURITY SYSTEMS NON-PLENUM CMR ASTM Bare or Tinned Copper High Grade PVC Insulation Aluminum Polyester Foil Shields with individual drains Paired Conductors Gray PVC Jacket MULTI-PAIR INDIVIDUALLY SHIELDED AWG & STRANDING NO. OF PAIRS NOM POSSIBLE USE & APPLICATIONS 5655AGR 561GRB 55EQGY 5681GR* 7 x 30 7 x 30 Solid TC 0 7 x Access Control Security Devices Sound & Audio Intercom Paging Background Music 5910AGR* 18 7 x MULTI-PAIR INDIVIDUAL & OVERALL SHIELDED 561GRR 7 x Conductor color code. overall shielded pairs Non-Stock, Call for Availability. *Conductor color code 8. Chart on page page 6. 13

16 SOUND & SECURITY SYSTEMS NON-PLENUM Intercom and Sound Systems Multi-Pair, Shielded & Unshielded CMR ASTM Bare Copper High Grade PVC Insulation Aluminum Polyester Foil Shield with drain Paired Conductors Riser Rated Gray PVC Jacket AWG & STRANDING NO. OF COND. NOM POSSIBLE USE & APPLICATIONS 5601GR 5611GR 5631GR 7 x 30 7 x 30 Solid 3 ( Shielded) (1 Unshielded) ( Shielded) ( Unshielded) 3 ( Shielded) (1 Unshielded) Access Control Security Devices Sound & Audio Intercom Paging Background Music 56GRB Solid ( Shielded) ( Unshielded) GR Solid 6 ( Shielded) ( Unshielded) GR 0 7 x 8 3 ( Shielded) (1 Unshielded) GR 0 7 x 8 ( Shielded) ( Unshielded) GR 18 7 x 6 ( Shielded).197 Conductor color code: SHIELDED: 1. Black,. Red UNSHIELDED: 3. White,. Green, 5. Brown, 6. Blue Non-Stock, Call for Availability. 1

17 SOUND & SECURITY SYSTEMS PLENUM CMP ASTM Bare Copper Premium LS PVC Insulation Twisted/Cabled Conductors Plenum Rated White Poly-flex Jacket MULTI-CONDUCTOR, UNSHIELDED AWG & STRANDING NO. OF COND. NOM POSSIBLE USE & APPLICATIONS 568Axx 569Axx 591AWH 569AWH Solid 7 x 30 7 x 30 Solid Access Control Security Devices Sound & Audio Intercom Paging Background Music 5650AWH 7 x AWH 7 x AWH 7 x AWH 7 x AWH 7 x WH 0 7 x AWH 18 Solid Axx 18 7 x AWH 18 7 x AWH 18 7 x AWH 18 7 x AWH 18 7 x AWH 18 7 x Conductor color code 1. Chart on page page 6. Non-Stock, Call for Availability. 15

18 SOUND & SECURITY SYSTEMS PLENUM CMP ASTM Bare Copper Premium LS PVC Insulation Twisted/Cabled Conductors Plenum Rated White Poly-flex Jacket MULTI-CONDUCTOR, UNSHIELDED AWG & STRANDING NO. OF COND. NOM POSSIBLE USE & APPLICATIONS 569AWH 569WH 5695AWH x x x Access Control Security Devices Sound & Audio Intercom Paging Background Music CL3P 5696AWH 56961WH 5697AWH 5698AWH 1 19 x x x x Access Control Security Devices Sound & Audio Intercom Paging Background Music Conductor color code 1. Chart on page page 6. * Non-Stock, Call for Availability. 16

19 SOUND & SECURITY SYSTEMS PLENUM MULTI-CONDUCTOR, OVERALL SHIELDED CMP ASTM Bare Copper Premium LS PVC Insulation Aluminum Polyester Foil Shield with drain Twisted/Cabled Conductors Plenum Rated White Poly-flex Jacket AWG & STRANDING NO. OF COND. NOM POSSIBLE USE & APPLICATIONS 56991WH 5699AWH 5900AWH 5631AWH Solid 7 x 30 7 x 30 7 x Access Control Security Devices Sound & Audio Intercom Paging Background Music 5660AWH 7 x AWH 7 x AWH 7 x AWH 7 x AWH 0 7 x AWH 18 Solid Axx 18 7 x AWH 18 7 x AWH 18 7 x AWH 18 7 x AWH 18 7 x AWH 18 7 x AWH x AWH x 9.10 Conductor color code 1. Chart on page page 6. * Non-Stock, Call for Availability. 17

20 SOUND & SECURITY SYSTEMS PLENUM CL3P ASTM Bare Copper Premium LS PVC Insulation Aluminum Polyester Foil Shield with drain Twisted/Cabled Conductors Plenum Rated White Poly-flex Jacket MULTI-CONDUCTOR, OVERALL SHIELDED AWG & STRANDING NO. OF COND. NOM POSSIBLE USE & APPLICATIONS 5908AWH 5913AWH 593AWH 1 19 x x x Access Control Security Devices Sound & Audio Intercom Paging Background Music Data and Communications Grade Multi-Conductor, Overall Shielded Low Capacitance CMP ASTM Bare Copper LoCap FPR Insulation Aluminum Polyester Foil Shield with drain Twisted/Cabled Conductors Plenum Rated White Poly-flex Jacket AWG & STRANDING NO. OF COND. NOM CAPACITANCE 5600AWH 7 x pf / ft 5699WH 7 x pf / ft Conductor color code 1. Chart on page page 6. Non-Stock, Call for Availability. 18

21 SOUND & SECURITY SYSTEMS PLENUM CMP ASTM Bare or Tinned Copper Premium LS PVC Insulation Aluminum Polyester Foil Shields with individual drains Paired Conductors Plenum Rated White Poly-flex Jacket MULTI-PAIR, INDIVIDUALLY SHIELDED AWG & STRANDING NO. OF PAIRS NOM POSSIBLE USE & APPLICATIONS 5631WH 5630WH* 56601WHB 568WH 7 x 30 7 x 30 7 x 30 7 x Access Control Security Devices Sound & Audio Intercom Paging Background Music 5630WH 7 x EQPL Solid TC AWH 18 7 x AWH 18 7 x * Individually shielded pairs + overall shield Conductor color code 1. Chart on page page 6. Non-Stock, Call for Availability. 19

22 SOUND & SECURITY SYSTEMS PLENUM CMP ASTM Bare Copper Premium LS PVC Insulation Aluminum Polyester Foil Shield with drain Paired Conductors Plenum Rated White Poly-flex Jacket Intercom and Sound Systems Multi-Pair, Shielded & Unshielded AWG & STRANDING NO. OF COND. NOM POSSIBLE USE & APPLICATIONS 56307WH 563WHR 5631WHR 7 x 30 Solid 7 x 30 3 ( Shielded) (1 Unshielded) ( Shielded) ( Unshielded) ( Shielded) ( Unshielded) Access Control Security Devices Sound & Audio Intercom Paging Background Music 56WH Solid 6 ( Shielded) ( Unshielded) WH 7 x 30 6 ( Shielded) ( Unshielded) AWH 0 7 x 8 ( Shielded) ( Unshielded) WH 18 7 x 6 ( Shielded).180 Conductor color code: SHIELDED: 1. Black,. Red UNSHIELDED: 3. White,. Green, 5. Brown, 6. Blue Non-Stock, Call for Availability. 0

23 SOUND & SECURITY SYSTEMS PLENUM CMP ASTM Bare Copper Premium LS PVC Insulation Aluminum Polyester Foil Shield with individual drains Twisted/Cabled Conductors Individual Plenum Rated Component Jackets Overall Plenum FPR Jacket Access Control Composite Multi-Conductor, Individually Shielded & Jacketed Components Overall Jacket AWG & STRANDING NO. OF COND. NOM APPLICATION 593AYW 18 7 x 6 6 Shielded.51 Card Reader 18 7 x 6 Shielded Motion/Rex 7 x 30 Shielded Door Contacts x 9 Shielded Lock Power Paige will custom design and specify any combination of ACCESS control composite cable. Just call Paige. Conductor color code 1. Chart on page page 6. 1

24 SOUND & SECURITY SYSTEMS PLENUM Access Control Composite Multi-Conductor, Individually Jacketed Components Shielded & Unshielded Components Bundled & Wrapped with Clear TapRibbon CMP ASTM Bare Copper Premium LS PVC Insulation Aluminum Polyester Foil Shield with individual drains Twisted/Cabled Conductors Individual Plenum Rated Component Jackets Clear Skip Wrapped Individually Jacketed White w/orange Stripe AWG & STRANDING NO. OF COND. OR PAIRS NOM APPLICATION 5W x 6 3 PR* OAS.5 Reader x 9 C Unshielded Lock 7 x 30 C Unshielded Door Contacts 7 x 30 C Unshielded Rex Product Features a ribbon wrapped bundle to secure the individual components. Ribbon wrap offers better flexibility and lower cost than overall FPR plenum jackets. Clear ribbon allows for high visibility color coding of the access control components. Paige will custom design and specify any combination of ACCESS control composite cable. Just call Paige. Conductor color code 1. *Conductor color code 8. Chart on page page 6.

25 FIRE ALARM SYSTEMS Power Limited Cables Paige fire alarm cables are designed for a wide range of applications in low voltage fire alarm systems. They carry the following listings in common: NFPA MEMBER C Temperature rated 300 volt UL Listed and Canadian UL Listed Most are dual listed to also meet NEC Articles 760 permitting cross application in sound and security systems Meet NEC Articles 800 and 75 Dual NEC / UL Listings for cables in this section: Gauge Sizes AWG 16 AWG Non-plenum FPL/CM Non-plenum Riser FPLR/CMR Plenum FPLP/CMP 1 AWG 1 AWG FPL/CL3 FPLR/CL3R FPLP/CL3P For additional information on NEC / UL see p in the technical section. Additional features of cables in this section: Twisted conductors for reduced cross-talk ASTM bare copper conductors Premium grade PVC for improved strength and flexibility When shielded, corrosion resistant tinned copper drain wires are used Color-coded conductors Cables Installed in Raceway For maximum installation flexibility, Paige offers a series of TFN and THHN, 600 volt cables, permitted for use in power limited fire alarm circuits under NEC Article Wiring Methods and Materials on Load Side of the PLFA Power Source and sub-section 760.5(A) NPLFA Wiring Methods and Materials. When installed in accordance with NEC Chapter 3, these cables deliver a number of speedy installation advantages: Rated TFN (18 and 16 AWG) or THHN (1 and 1 AWG) 90 C dry / 75 C wet Rated 600 volts Available in singles or Easy-pull pre-twisted, color-coded pairs Available in flexible metal armor 3

26 FIRE ALARM SYSTEMS CONDUCTOR COLOR CHART Color Code 1 Black Red 3 Brown Blue 5 Orange 6 Yellow 7 Purple 8 Green 9 Red / Black 10 Red / White 11 Red / Green 1 Red / Blue Color Code 7 Cond # AWG 1 Black Red 3 Blue Orange 1-1 AWG Black White Red Blue Conductor Colors BE BK BL BR GN Beige Black Blue Brown Green GR OR PK PR Gray Orange Pink Purple RE VI WH YW Red Violet White Yellow

27 FIRE ALARM SYSTEMS NON-PLENUM TFN or THHN ASTM Solid Bare Copper PVC & Nylon Insulation Twisted/Cabled Conductors Unjacketed PAIRED, UNJACKETED, UNSHIELDED 600V Low Capacitance AWG & STRANDING NO. OF COND. NOM CONDUCTOR COLORS 5318BR 18 Solid.165 Bk / Re 5316BR 16 Solid.190 Bk / Re 531BR 1 Solid. Bk / Re THHN ASTM Bare Copper PVC Insulation Nylon Jacket SINGLE CONDUCTOR, UNSHIELDED 600V AWG & STRANDING NO. OF COND. NOM POSSIBLE USE & APPLICATIONS x BK, BL, BR, GN, PK, RE, VI, WH, YW Solid 1.11 GN 5

28 FIRE ALARM SYSTEMS NON-PLENUM FPLR ASTM Bare Copper High Grade PVC Insulation Twisted/Cabled Conductors Riser Rated Red PVC Jacket MULTI-CONDUCTOR, UNSHIELDED AWG & STRANDING NO. OF COND. NOM POSSIBLE USE & APPLICATIONS 5606Axx 5703Axx 570Axx 5705ARE Solid 18 Solid 18 Solid 18 Solid I/O SLC Loop Addressable Devices Power Horns/Strobes Panel Interconnects Speaker 5706ARE 18 Solid ARE 18 Solid Axx 16 Solid ARE 16 7 x ARE 16 Solid Axx 1 Solid RE 1 7 x ARE 1 Solid.6 570ARE 1 Solid ARE 1 Solid.303 For non-twisted zip fire alarm cables, see page 37. Conductor color code. Chart on page. Non-Stock, Call for Availability. 6

29 FIRE ALARM SYSTEMS NON-PLENUM FPL ASTM Bare Copper Low Density PE Insulation Twisted/Cabled Conductors Red PVC Jacket DATA ADDRESSABLE CABLE Multi-Conductor, Unshielded Low Capacitance AWG & STRANDING NO. OF COND. NOM CAPACITANCE 5703RE 18 Solid pf / FT 57311RE 16 Solid pf / FT MULTI-CONDUCTOR, OVERALL SHIELDED FPLR ASTM Bare Copper High Grade PVC Insulation Aluminum Polyester Foil Shield with drain Twisted/Cabled Conductors Riser Rated Red PVC Jacket AWG & STRANDING NO. OF COND. NOM POSSIBLE USE & APPLICATIONS 57ARE 573ARE 5735ARE 5736ARE 18 Solid 18 Solid 18 Solid 16 Solid I/O SLC Loop Addressable Devices Power Horns/Strobes Panel Interconnects Speaker 5737ARE 16 Solid ARE 1 Solid ARE 1 Solid ARE 1 Solid.6 Conductor color code. Chart on page. Non-Stock, Call for Availability. 7

30 FIRE ALARM SYSTEMS NON-PLENUM DATA ADDRESSABLE CABLE Multi-Conductor, Overall Shielded Mid Capacitance FPL ASTM Bare Copper Low Density Polyethylene Insulation Aluminum Polyester Foil Shield with drain Twisted/Cabled Conductors Red PVC Jacket AWG & STRANDING NO. OF COND. NOM CAPACITANCE 57AREM 18 Solid pf / ft 5736AREM 16 Solid pf / ft 576AREM 1 Solid pf / ft Conductor color code. Chart on page. Non-Stock, Call for Availability. 8

31 FIRE ALARM SYSTEMS PLENUM FPLP ASTM Bare Copper Premium LS PVC Insulation Twisted/Cabled Conductors Plenum Rated Red Poly-flex Jacket MULTI-CONDUCTOR, UNSHIELDED AWG & STRANDING NO. OF COND. NOM POSSIBLE USE & APPLICATIONS 5709ARE 5711ARE 5713ARE 571ARE 18 Solid 18 Solid 18 Solid 18 Solid I/O SLC Loop Addressable Devices Power Horns/Strobes Panel Interconnects Speaker 570ARE 16 Solid ARE 16 Solid Axx 1 Solid ARE 1 Solid ARE 1 Solid. 57ARE 1 Solid.303 Conductor color code. Chart on page. Non-Stock, Call for Availability. 9

32 FIRE ALARM SYSTEMS PLENUM MULTI-CONDUCTOR, OVERALL SHIELDED FPLP ASTM Bare Copper Premium LS PVC Insulation Aluminum Polyester Foil Shield with drain Twisted/Cabled Conductors Plenum Rated Red Poly-flex Jacket AWG & STRANDING NO. OF COND. NOM POSSIBLE USE & APPLICATIONS 5717ARE 575ARE 576ARE 577ARE 18 Solid 18 Solid 18 Solid 16 Solid I/O SLC Loop Addressable Devices Power Horns/Strobes Panel Interconnects Speaker 578ARE 16 Solid ARE 1 Solid ARE 1 Solid. 5750ARE 1 Solid.8 Conductor color code. Chart on page. Non-Stock, Call for Availability. 30

33 FIRE ALARM SYSTEMS PLENUM DATA ADDRESSABLE CABLE Multi-Conductor, Overall Shielded Mid Capacitance FPLP ASTM Bare Copper Mid Cap FPR Insulation Aluminum Polyester Foil Shield with drain Twisted/Cabled Conductors Plenum Rated Red Poly-flex Jacket AWG & STRANDING NO. OF COND. NOM CAPACITANCE 5717AREM 18 Solid pf / ft 577AREM 16 Solid pf / ft 577AREM 1 Solid pf / ft Conductor color code. Chart on page. Non-Stock, Call for Availability. 31

34 FIRE ALARM SYSTEMS WIRE DISTINGUISHER Circuit Tracer System Distinguisher approved Fire Alarm Cables with Color-Striped Jackets A color code stripe is embedded in the red cable jacket not an imprint! All cables are dual marked per the latest articles of the NEC Code. Examples: Horns & Strobes Speakers Data Communication (SLC) Annunciator Communication VDC Power Annunciator Power alternative color stripes available. Simplifies system servicing and expansion. 3

35 FIRE ALARM SYSTEMS NON-PLENUM FPLR ASTM Bare Copper Mid Cap PVC Insulation Twisted/Cabled Conductors Riser Rated Red Poly-flex Jacket with imbedded Stripe DISTINGUISHER Multi-Conductor, Unshielded Mid-Capacitance AWG & STRANDING NO. OF COND. NOM STRIPE COLORS 7518MRN 18 Solid.1 BL, BR, GR, PR, YL 7516MRN 16 Solid.170 BL, BR, GR, PR, YL 751MRN 1 Solid.10 BL, GY, OR, PR 751MRN 1 Solid.38 GY, OR DISTINGUISHER Multi-Conductor, Overall Shielded FPLR ASTM Bare Copper Mid Cap PVC Insulation Aluminum Polyester Foil Shield with drain Twisted/Cabled Conductors Riser Rated Red Poly-flex Jacket with imbedded Stripe 7518SRN 18 Solid.17 BL, BR, YL 7516SRN 16 Solid.168 BL, BR, YL Conductor color code. Chart on page. Non-Stock, Call for Availability. 33

36 FIRE ALARM SYSTEMS PLENUM DISTINGUISHER Multi-Conductor, Unshielded Mid-Capacitance FPLP ASTM Bare Copper FPR Insulation Twisted/Cabled Conductors Plenum Rated Red Poly-flex Jacket with imbedded stripe AWG & STRANDING NO. OF COND. NOM STRIPE COLORS 7518MPN 18 Solid.150 GR 7516MPN 16 Solid.171 BL, GR, WH, YL 751MPN 1 Solid.06 BL, GY, PR, YL 751MPN 1 Solid.0 GY FPLP ASTM Bare Copper FPR Insulation Aluminum Polyester Foil Shield with drain Twisted/Cabled Conductors Plenum Rated Red Poly-flex Jacket with imbedded stripe 7518SPN 18 Solid.150 BL, BR, YL 7516SPN 16 Solid.169 BL, BR, GR, OR, PR, YL Conductor color code. Chart on page. Non-Stock, Call for Availability. 3

37 FIRE ALARM SYSTEMS PLENUM FPLP / CL3P ASTM Bare Copper Premium LS PVC Insulation Twisted/Cabled Conductors Overall Red LS Plenum Rated PVC Jacket SOUNDER BASE Multi-Pair, Unshielded Composite Cable AWG & STRANDING NO. OF COND. NOM Capacitance 75118MP 1 Solid AWG pf/ Ft 18 Solid 18 AWG pf / Ft Ideal for hotels, apartments and multi-unit dwellings where there is a need for individual unit alarms combined with group, zone or general alarms. This cable simplifies the installation of multiple sounder base units by combining the individual unit signal cable with a group signal cable. The cable is designed with individually twisted pairs combined in an overall twisted pattern providing optimum electrical properties for Sounder Base installation. Conductor color code. Chart on page. 35

38 FIRE ALARM SYSTEMS NON-PLENUM CIRCUIT INTEGRITY (CI) Multi-Conductor, Overall Shielded FPLR-CI ASTM Bare Copper UL196 Twisted/Cabled Conductors Copper Shield with drain Flame Retardant, LS Zero Halogen Polyolefin Jacket AWG & STRANDING NO. OF COND. NOM CAPACITANCE 5160SCI 16 Solid pf / ft 510SCI 1 Solid pf / ft 510SCI 1 Solid pf / ft TYPE CI: Among the many features of this hour fire rated cable is the fact that it does not need to be installed in conduit. This product passed the UL196 fire test and fire hose test without being installed in conduit and therefore was given the designation of CI (Fire Alarm Circuit Integrity Cable) as defined in Article 760 of the National Electrical Code. Whether installing in conduit or not, this feature can provide considerable cost savings over other hour rated installations that typically require fire-rated walls and strict conduit support spacing standards. Meets survivability requirements and NFAC. Both conductors are black with words 1. Black &. Red. 36

39 FIRE ALARM SYSTEMS NON-PLENUM FPL ASTM Bare Copper High Grade PVC Insulation Red, Parallel Conductors Unjacketed PARALLEL ZIP WIRE, UNSHIELDED AWG & STRANDING NO. OF COND. NOM CONDUCTOR COLORS 5700ARE 18 Solid.110 x.13 RE 5701ARE 16 Solid.115 x.30 RE 570ARE 1 Solid.16 x.5 RE FPLP PLENUM ASTM Bare Copper Premium LS PVC Insulation Non-Twisted Conductors Plenum Rated Red Poly-flex Jacket MULTI-CONDUCTOR, UNSHIELDED Non-Twisted Color Coded Conductors Overall Jacket AWG & STRANDING NO. OF COND. NOM ALTERNATE JACKET COLORS 5758ARE 16 Solid ARE 1 Solid.06 WH With tracer and stripe. Conductor color code. Chart on page. Non-Stock, Call for Availability. 37

40 FIRE ALARM SYSTEMS CORRA/CLAD MC CABLE CORRA/CLAD Corrugated Aluminum Sheath Separator Tape Fillers Type TFN, TFFN or THHN Insulation Copper Conductor UL LISTED MC CABLE Corra/Clad is constructed in accordance with Underwriters Laboratories, Inc., standard for Metal-Clad Cable (UL 1569). Corra/Clad meets or exceeds interlocked MC cable. Corra/Clad can be used everywhere interlocked MC cable can be used plus additional places MC cable can t be used. HEALTH CARE FACILITIES Corra/Clad s outer jacket is an approved grounding means of a listed cable assembly and employs a continuous, gas/vapor tight metal sheath. Corra/Clad is permitted for use in hospitals and health care facilities, including all patient care areas per Article (a) and (b). A properly sized ground must also be a part of the listed assembly. When Corra/Clad is ordered with a separate ground the green ground wire is marked ISOLATED GROUND COND. For Health Care Facility wiring Corra/Clad has quickly become the preferred method of wiring for these facilities. (Consult local authorities for special inclusions or restrictions.) FIRE RESISTANT Due to its solid fill construction, smoke can not chimney through the continuous sheath. This lack of oxygen makes Corra/Clad and Metal Clad squared fire resistant. Corra/Clad may be used in a plenum area per Article 300-(b) of the NEC. FIRE/CLAD MC CABLE Our Fire/Clad MC Cable is Corra/Clad cable with a red ink coloring on the aluminum sheath to designate the cable as part of a fire alarm system. Fire/Clad and Corra/Clad is dual rated as MC Cable and as FPL Cable. 38

41 FIRE ALARM SYSTEMS SUITABLE FOR PLENUM MC / FPL ASTM Bare Copper Type TFN/TFFN & THHN PVC and Nylon Insulation Cabled Conductors Aluminum Sheath Water and Fire Resistant CORRA/CLAD MC CABLE Multi-Conductor, Unshielded AWG & STRANDING NO. OF COND. NOM CONDUCTOR COLORS 5180MC 18 Solid.335 BK, RE 5180MC 18 Solid.370 BK, RE, BL, OR 5160MC 16 Solid.355 BK, RE 5160MC 16 Solid.395 BK, RE, BL, OR 510MC 1 Solid.380 BK, WH 510MC 1 Solid.5 BK, WH, RE, BL 510MC 1 Solid.05 BK, WH 510MC 1 Solid.60 BK, WH, RE, BL Operating Temperature 90 c / Max Voltage 600v Suitable for plenum per NEC Article 300-(b) Protective metal sheath marked with red color stripe (other colors available upon request) Conductor color code 7. Chart on page. Non-Stock, Call for Availability. 39

42 FIRE ALARM SYSTEMS SUITABLE FOR PLENUM MC / FPL ASTM Solid Bare Copper Type TFN/TFFN & THHN PVC and Nylon Insulation Aluminum Sheath Water and Fire Resistant CORRA/CLAD MC CABLE Multi-Paired Unshielded Composite Cables 5MC01 5MC0 5MC03S 5MC301 5MC01 PAIR NO AWG & STRANDING 1 Solid 1 Solid 18 Solid SHIELDED 1 Solid 16 Solid 1 Solid 16 Solid 1 Solid 1 Solid 16 Solid 1 Solid 1 Solid 1 Solid USE Speaker Strobe EIA-85 v DC SLC MidCap v DC SLC MidCap Strobe v DC SLC MidCap Strobe Speaker v DC CONDUCTOR COLORS Re / Bk Yw / Bl Re / Bk Or / Bl Re / Gr Pk / Vi Re / Gr Yw / Bl Pk / Vi Re / Gr Yw / Bl Re / Bk Pk / Vi Operating Temperature 90 c / Max Voltage 600v Suitable for plenum per NEC Article 300-(b), 33 & 760 Protective metal sheath marked with red color stripe (other colors available upon request) 0

43 COAXIAL CABLE Paige coaxial cables are designed for sophisticated security surveillance, and today s high tech multi-media distribution systems that require wide bandwidth transmissions and low loss signals. They carry the following listings in common: 75 C Temperature rated UL Listed and Canadian UL Listed Meets NEC Article 80 UL Listings for cables in this section: CATV / MATV CCTV Non-Plenum Plenum Non-Plenum Plenum RG59 & RG6 CATV / CM CATVP / CMP CM CMP RG11 CATV / CL3 CATV / CL3P CL3 CL3P For additional information on NEC / UL see p in the technical section. Additional features of cables in this section: Sunlight resistant jackets Solid bare copper cores and 95% bare copper braids for reduced dc resistance and improved CCTV low frequency transmissions Foil and braid shield combined for CATV transmissions to protect both high and low frequencies from ambient noise 1

44

45 COAXIAL CABLES NON-PLENUM CATV / CL3 or CM ASTM Bare Copper or Copper Clad Steel Low Density Polyethylene Insulation Overall Black Sunlight Resistant PVC Jacket RG ABL AWG & STRANDING SHIELD Solid CCS 0% Al Braid +100% Al Foil NOM. CATV POSSIBLE USE & APPLICATIONS RG6 581ABL 18 Solid BC 65% Al Braid + 100% Al Foil.75 CATV 5810AWH 18 Solid BC 60% Al Braid +100% Al Foil 0% Al Braid +100% Al Foil.300 RG11 581ABL 1 Solid BC 65% Al Braid + 100% Al Foil.05 CATV For Outdoor Versions see Page 71. Non-Stock, Call for Availability. 3

46 COAXIAL CABLES NON-PLENUM CL3 or CM ASTM Bare Copper Foamed Polyethylene Insulation Bare Copper Shield Overall Black Sunlight Resistant PVC Jacket RG59 AWG & STRANDING SHIELD NOM POSSIBLE USE & APPLICATIONS 5800ABLS 0 Solid BC 95% BC Braid. CCTV 5806ABL 0 Solid BC 18/ 7 x 6 (Siamese) 95% BC Braid. x.60 CCTV & POWER RG6 580ABLS 18 Solid BC 95% BC Braid.70 CCTV 58ABK 18 Solid BC 16/ 19 x 9 (Siamese) 95% BC Braid.60 CCTV & POWER RG ABL 1 Solid BC 95% BC BRAID.05 CCTV For Outdoor Versions see Page 71.

47 COAXIAL CABLES NON-PLENUM CATV / CM Tinned Copper Foamed Polyethylene Insulation Aluminum Polyester Foil Shield with drain Individually Jacketed Mini Coaxial Cables Overall Black Sunlight Resistant PVC Jacket RGB COMPOSITE VIDEO (RGBHV) 58ABK AWG & STRANDING SHIELD NOM INTERNAL JACKET COLORS 6 7 x 3 TC 93% TC Braid.05 Re/GN/Bl/BK/YW Each coax is individually jacketed with color coded PVC. The coax cables are cabled together and shielded with an overall aluminum / polyester foil tape. To complete construction an overall black PVC jacket is applied. Non-Stock, Call for Availability. 5

48 COAXIAL CABLES PLENUM CATVP / CMP or CL3P ASTM Bare Copper Fluoropolymer Insulation Plenum Rated White Poly-flex Jacket RG6 AWG & STRANDING SHIELD NOM POSSIBLE USE & APPLICATIONS 5813AWH 18 Solid BC 90% Al Braid + 100% Al Foil.50 CATV MATV 5811AWH 18 Solid BC 75% Al Braid +100% Al Foil 55% Al Braid +100% Al Foil.6 RG AWH 1 Solid BC 65% Al Braid + 100% Al Foil.36 CATV MATV 6

49 COAXIAL CABLES PLENUM CL3P / CMP ASTM Bare Copper Fluoropolymer Insulation Plenum Rated White Poly-flex Jacket RG59, CCTV AWG & STRANDING SHIELD NOM POSSIBLE USE & APPLICATIONS 5801Axx 0 Solid BC 95% BC Braid.190 CCTV & POWER 580AWH 0 Solid BC 18/ 7x 6 (Siamese) 95% BC Braid.19 x.360 RG6, CCTV 5803Axx 18 Solid BC 95% BC Braid.76 CCTV & POWER 583AWH 18 Solid BC 16/ 19 x 9 (Siamese) 95% BC Braid.75 x.90 Non-Stock, Call for Availability. 7

50 COAXIAL CABLES NON-PLENUM RG59 CCTV PATCH CABLE BNC Male to Male CM ASTM Bare Copper Foamed Polyethylene Insulation Bare Copper Shield Overall Black Sunlight Resistant PVC Jacket Terminated each end with crimp on BNC 75 ohm connectors AWG & STRANDING SHIELD NOM LENGTH SOLID BC 95% BC Braid SOLID BC 95% BC Braid SOLID BC 95% BC Braid SOLID BC 95% BC Braid SOLID BC 95% BC Braid. 10 8

51 LAN, DATA & NETWORK SOLUTIONS Paige LAN, Data & Network cables are designed for top network performance and reliability. They are available in a variety of colors for fast cable identification. They carry the following listings in common: 75 C Temperature rated 300 volt UL Listed Meets NEC Article 800 ETL Verified to applicable TIA/EIA standards NEC / UL Listings for cables in this section: Gauge Sizes Non-plenum Non-plenum Riser Plenum AWG AWG CM / MP CMR CMP / MPP For additional information on NEC / UL see p in the technical section. Additional features of cables in this section: Staggered twisted pairs for reduced cross-talk ASTM bare copper conductors Premium grade PVC for improved strength and flexibility (CAT 3) DataCap low capacitance insulators for improved signal strength (CAT 5-CAT 6) When shielded, corrosion resistant tinned copper drain wires are used Telco standard color-coded conductors 9

52 LAN, DATA & NETWORK SOLUTIONS CONDUCTOR COLOR CHART Color Code 6 Pair # 1st/nd 1 White/Blue-Blue White/Orange-Orange 3 White/Green-Green White/Brown-Brown Color Code 9 Pair # 1st Conductor 1 White / Blue White / Orange 3 White / Green White / Brown 5 White / Slate 6 Red / Blue 7 Red / Orange 8 Red / Green 9 Red / Brown 10 Red / Slate 11 Black / Blue 1 Black / Orange 13 Black / Green 1 Black / Brown 15 Black / Slate 16 Yellow / Blue 17 Yellow / Orange 18 Yellow / Green 19 Yellow / Brown 0 Yellow / Slate 1 Violet / Blue Violet / Orange 3 Violet / Green Violet / Brown 5 Violet / Slate nd Conductor Blue / White Orange / White Green / White Brown / White Slate / White Blue / Red Orange / Red Green / Red Brown / Red Slate / Red Blue / Black Orange / Black Green / Black Brown / Black Slate / Black Blue / Yellow Orange / Yellow Green / Yellow Brown / Yellow Slate / Yellow Blue / Violet Orange / Violet Green / Violet Brown / Violet Slate / Violet Conductor Colors 50 BE BK BL BR GN Beige Black Blue Brown Green GR OR PK PR Gray Orange Pink Purple RE VI WH YW Red Violet White Yellow

53 LAN, DATA & NETWORK SOLUTIONS NON-PLENUM CMR ASTM Bare Copper High Grade PVC Insulation Paired Conductors Riser Rated Gray PVC Jacket CATEGORY 3 Unshielded Twisted Pairs (UTP) AWG & STRANDING NO. OF PAIRS NOM POSSIBLE USE & APPLICATIONS Solid Solid Voice or Data UTP Video Solid Solid Solid Solid Solid Conductor color code 9. Chart on page 50. Non-Stock, Call for Availability. 51

54 LAN, DATA & NETWORK SOLUTIONS PLENUM CMP ASTM Bare Copper High Grade PVC Insulation Paired Conductors Plenum Rated White Poly-flex Jacket CATEGORY 3 Unshielded Twisted Pairs (UTP) AWG & STRANDING NO. OF PAIRS NOM POSSIBLE USE & APPLICATIONS Solid Solid Voice or Data UTP Video Solid Solid Solid Solid Solid Conductor color code 9. Chart on page 50. Non-Stock, Call for Availability. 5

55 LAN, DATA & NETWORK SOLUTIONS NON-PLENUM CMR ASTM Bare Copper DataCap FE Insulation Paired Conductors Riser Rated Misc. Colors PVC Jacket CATEGORY 5E Unshielded Twisted Pairs (UTP) AWG & STRANDING NO. OF PAIRS NOM POSSIBLE USE & APPLICATIONS 71058E Solid.185 Voice or Data UTP Video 71055E* Solid 350 MHZ.185 Conductor color code 9. *Conductor color code 6. Chart on page 50. For Outdoor versions see p.7. 53

56 LAN, DATA & NETWORK SOLUTIONS PLENUM CMP / MPP ASTM Bare Copper DataCap FP Insulation Paired Conductors Plenum Rated Misc. Colors PVC Jacket CATEGORY 5E Unshielded Twisted Pairs (UTP) AWG & STRANDING NO. OF PAIRS NOM POSSIBLE USE & APPLICATIONS E Solid.185 Voice or Data UTP Video E* Solid 350 MHZ.185 Conductor color code 9. *Conductor color code 6. Chart on page 50. 5

57 LAN, DATA & NETWORK SOLUTIONS PLENUM CMP ASTM Bare Copper LoCap FPR Insulation Paired Conductors Plenum Rated Gray Poly-flex Jacket CATEGORY 5, POWERSUM Unshielded Twisted Pairs (UTP) PL AWG & STRANDING Conductor color code 9. Chart on page 50. For Outdoor version see page 7. NO. OF PAIRS NOM Solid 5.00 Network Trunk POSSIBLE USE & APPLICATIONS 55

58 LAN, DATA & NETWORK SOLUTIONS NON-PLENUM CM ASTM Bare Copper High Density Polyethylene Insulation Paired Conductors PVC Jacket CATEGORY 5E, PATCH CABLES Unshielded, Unbooted Modular Plug AWG & STRANDING 7 x 3 7 x 3 7 x 3 7 x 3 7 x 3 7 x 3 7 x 3 NO. OF PAIRS Housing: 3 Clear, Polycarbonate, UL9V09 RJ-5 Contact: 3 High Strength Copper Alloy 3 Gold Plating Over 100 Micro Inch Nickel Gold Plating: 3 50 Micro Inch/1,7 Micron Min. of Contact Number Of Contacts: 3 Eight NOM LENGTH Available jacket colors: BK, BL, GN, OR, PR, PK, RE, WH, YW Conductor color code 9. Chart on page

59 LAN, DATA & NETWORK SOLUTIONS NON-PLENUM CATEGORY 5E, PATCH CABLES Unshielded, Booted CM ASTM Bare Copper High Density Polyethylene Insulation Paired Conductors Booted Design PVC Jacket Modular Plug AWG & STRANDING 7 x 3 7 x 3 7 x 3 7 x 3 7 x 3 7 x 3 7 x 3 NO. OF PAIRS Housing: 3 Clear, Polycarbonate, UL9V09 RJ-5 Contact: 3 High Strength Copper Alloy 3 Gold Plating Over 100 Micro Inch Nickel Gold Plating: 3 50 Micro Inch/1,7 Micron Min. of Contact Number Of Contacts: 3 Eight NOM LENGTH Available jacket colors: BK, BL, GN, OR, PR, PK, RE, WH, YW Conductor color code 9. Chart on page

60 LAN, DATA & NETWORK SOLUTIONS NON-PLENUM TIA/EIA CERTIFIED CATEGORY 6 Unshielded Twisted Pairs UTP CMR ASTM Bare Copper DataCap FE Insulation Paired Conductors X-Beam Spacer Riser Rated LS PVC Jacket AWG & STRANDING NO. OF PAIRS NOM POSSIBLE USE & APPLICATIONS 3 SOLID.0 Voice or Data UTP Video PLENUM CMP DataCap FP Insulation SOLID.0 Voice or Data UTP Video These cables are specially designed to exceed the TIA/EIA 568 B.-1 standard for next generation category 6 cabling. They are constructed of four precision balanced pairs, held in correct alignment by means of a unique central X-Beam spacer. For systems operating from 10Mb/s to 1000Mb/s, these cables provide the necessary headroom and bandwidth to support the most robust applications. Conductor color code 9. Chart on page 50. Non-Stock, Call for Availability. 58

61 THERMOSTAT CABLE Paige thermostat cables can be used for low voltage applications such as thermostat controls or HVAC equipment. They are available with a brown jacket for easy cable identification. They carry the following listings in common: 75 C Temperature rated 300 volt UL Listed and Canadian UL Listed Meet NEC Article 75 NEC / UL Listings for cables in this section: Gauge Sizes 18 AWG Plenum CMP For additional information on NEC / UL see p in the technical section. Additional features of cables in this section: ASTM bare copper conductors Premium grade PVC for improved strength and flexibility Color-coded conductors 59

62 THERMOSTAT CABLE CONDUCTOR COLOR CHART Color Code 5 Conductor Colors Red White Blue Green Brown Black Yellow Orange Purple Gray Tan Pink Light Blue White w/blue Stripe White w/black Stripe White w/brown Stripe White w/red Stripe Red w/white Stripe Blue w/white Stripe Green w/white Stripe BE BK BL BR GN GR Beige Black Blue Brown Green OR PK PR RE Gray Orange Pink Purple VI WH YW Red Violet White Yellow 60

63 THERMOSTAT CABLE PLENUM CMP ASTM Bare Copper Premium LS PVC Insulation Cabled Conductors Plenum Rated Brown Poly-flex Jacket Unshielded AWG & STRANDING NO. OF COND. NOM POSSIBLE USE & APPLICATIONS 51805CTP 18 SOLID WH 51806CTP 18 SOLID 6.19 WH 51808CTP 18 SOLID 8.5 WH Conductor color code 5. Chart on page 60. Non-Stock, Call for Availability. 61

64

65 OUTDOOR APPLICATIONS Paige has put together a complete line of sunlight resistant outdoor cables for aerial or burial applications. Because Paige is #1 in the irrigation control, turf management and landscape markets, we have the expertise to hook you up with just the right product for your outdoor need. In this section you ll find a small sample of what we can do to help you, whether you re flying it, burying it, laying it on a roof, or pulling it through a buried conduit. For example, we can set you up with cables for all of the following applications: Access control Closed circuit cameras CATV distribution FA Panel Communications FA SLC loops Intercom s & paging Perimeter Security Power cable Speakers Sprinkler control And many more. Some of the cable features you ll find in this section: Tough, proven jackets and insulation s 30, 300 and 600 volt rated cables 75, 90 and 105 C temperature ratings ASTM bare or tinned copper Dry tape water-blocking constructions Wide range of UL listings to cover every need: TC / FPL / CM / CL3 / DB 63

66 OUTDOOR APPLICATIONS CONDUCTOR COLOR CHART Color Code 1 1 Black Red 3 White Green 5 Brown 6 Blue 7 Orange 8 Yellow 9 Purple 10 Gray 11 Pink 1 Tan 13 White / Black 1 White / Red 15 White / Green 16 White / Orange 17 White / Blue 18 White / Brown 19 White / Yellow 0 White / Purple 1 White / Gray Black / Red 3 Black / Green Black / Yellow 5 Black / Blue 6 Black / Brown 7 Black / Orange 8 Black / Gray 9 Black / Purple 30 Red / Green Color Code 3 1 Black White 3 Red Green 5 Brown 6 Blue 7 Orange 8 Yellow 9 Purple 10 Gray 11 Pink 1 Tan Color Code 5 1 Red White 3 Blue Green 5 Brown 6 Black 7 Yellow 8 Orange 9 Purple 10 Gray 11 Tan 1 Pink 13 Light Blue 1 White w/blue Stripe 15 White w/black Stripe 16 White w/brown Stripe 17 White w/red Stripe 18 Red w/white Stripe 19 Blue w/white Stripe 0 Green w/white Stripe 6

67 OUTDOOR APPLICATIONS CONDUCTOR COLOR CHART Color Code 9 Pair # 1st Conductor 1 White / Blue White / Orange 3 White / Green White / Brown 5 White / Slate 6 Red / Blue 7 Red / Orange 8 Red / Green 9 Red / Brown 10 Red / Slate 11 Black / Blue 1 Black / Orange 13 Black / Green 1 Black / Brown 15 Black / Slate 16 Yellow / Blue 17 Yellow / Orange 18 Yellow / Green 19 Yellow / Brown 0 Yellow / Slate 1 Violet / Blue Violet / Orange 3 Violet / Green Violet / Brown 5 Violet / Slate nd Conductor Blue / White Orange / White Green / White Brown / White Slate / White Blue / Red Orange / Red Green / Red Brown / Red Slate / Red Blue / Black Orange / Black Green / Black Brown / Black Slate / Black Blue / Yellow Orange / Yellow Green / Yellow Brown / Yellow Slate / Yellow Blue / Violet Orange / Violet Green / Violet Brown / Violet Slate / Violet Conductor Colors BE BK BL BR GN GR Beige Black Blue Brown Green Gray PK PR RE VI WH YW Pink Purple Red Violet White Yellow OR Orange 65

68 OUTDOOR APPLICATIONS ASTM Bare Copper High Grade PVC Insulation Cabled Conductors Black Sunlight Resistant PE Jacket with Nylon Rip Cord AERIAL or DIRECT BURIAL Multi-Conductor, Unshielded (For Outdoor Use Only, Not Indoors) AWG & STRANDING NO. OF COND. NOM UL SOLID.195 DB SOLID 3.05 DB SOLID.5 DB SOLID 5.5 DB SOLID 6.65 DB SOLID 7.80 DB SOLID 8.90 DB SOLID DB SOLID DB SOLID 1.30 DB SOLID DB 30 volts Conductor color code 5. Chart on page 6. 66

69 OUTDOOR APPLICATIONS ASTM Bare Copper PVC Insulation Water Blocking Twisted/Cabled Conductors Black Sunlight Resistant PVC Jacket Indoor / Outdoor UL Listed AERIAL or DIRECT BURIAL Multi-Conductor, Unshielded, Waterblocked AWG & STRANDING NO. OF COND. NOM UL 5180WDB 18 7 x 6.60 CM / FPL / TC / DB 5160WDB x 9.80 CM / FPL / TC / DB 510WDB * 1 19 x CL3 / FPL / TC / DB 510WDB * 1 19 x 5.35 CL3 / FPL / TC / DB Conductor color code 1. * Conductor color code 3 Chart on page 6. 67

70 OUTDOOR APPLICATIONS ASTM Bare Copper PVC Insulation Aluminum Polyester Foil Shield with drain Water Blocking Twisted/Cabled Conductors Black Sunlight Resistant PVC Jacket Indoor / Outdoor UL Listed AERIAL or DIRECT BURIAL Multi-Conductor, Overall Shielded, Waterblocked AWG & STRANDING NO. OF COND. NOM UL 5180SDB 18 7 x 6.65 CM / FPL / TC / DB 5180SDB 18 7 x 6.98 CM / FPL / TC / DB 51806SDB 18 7 x CM / FPL / TC / DB 5160SDB x 9.8 CM / FPL / TC / DB 510SDB 1 19 x 6.31 CM / FPL / TC / DB Conductor color code 1. Chart on page 6. 68

71 OUTDOOR APPLICATIONS ASTM Bare or Tinned Copper Wet Location Insulation Aluminum Polyester Foil Shield with drain Paired Conductors Black Sunlight Resistant Jacket AERIAL or DIRECT BURIAL Multi-Pair, Overall Shielded AWG & STRANDING NO. OF PAIRS NOM UL SOLID, FILLED 5.50 DB 5160PSTC* 16 7 x TC.377 TC *Each pair is Black / White and numbered 1 or. Conductor color code 9. Chart on page

72 OUTDOOR APPLICATIONS CM / CL3 ASTM Tinned Copper PVC Insulation Aluminum Polyester Foil Shields with individual drains Water Blocking Twisted/Cabled Conductors Gray Sunlight Resistant PVC Jacket AERIAL or CONDUIT BURIAL Multi-Pair, Individually Shielded, Waterblocked AWG & STRANDING NO. OF PAIRS NOM UL 501SWB SOLID TC SWB SOLID TC (1 Pr Shielded) (1 Pr Unshielded) SWB* SOLID TC 3 (1 Pr Shielded) ( Pr Unshielded) PSWB** SOLID TC PSWB** SOLID TC SDB 18 7 x 6 (1 Pr, SHIELDED).305 DB * Conductor Color Code 3 ** Conductor Color Code 9 Conductor color code 1. Chart on page Non-Stock, Call for Availability. 70

73 OUTDOOR APPLICATIONS ASTM Copper Clad Steel Foam PE Insulation Aluminum Braid plus Aluminum Foil Shield Black Sunlight Resistant Jacket AERIAL or DIRECT BURIAL Coaxial CATV, RG6 & RG11 AWG & STRANDING SHIELD NOM UL 581FDB 18 Solid CCS Flooded 60% Al Braid + 100% Al Foil.70 RG6 DB 581DB 1 Solid CCS Flooded 65% Al Braid + 100% Al Foil.00 RG11 DB ASTM Bare Copper Foam PE Insulation Bare Copper Braid Black Sunlight Resistant Jacket AERIAL or DIRECT BURIAL Coaxial CCTV, RG6 AWG & STRANDING SHIELD NOM UL 580ABL 18 SOLID BC 95% BC Braid.7 DB 586ABL 18 SOLID BC + 16 AWG HIGH STRENGTH C OOPER COATED SteeL Messenger 95% BC Braid.70 x.00 DB Non-Stock, Call for Availability. 71

74 OUTDOOR APPLICATIONS AERIAL or DIRECT BURIAL Category 5e, Unshielded Twisted Pairs (UTP) ASTM Bare Copper MIL-C-60A Water Polyolefin Insulation Penetration Requirement Paired Conductors Fully Flooded, Waterproof Black Sunlight and Water Resistant PE Jacket 71058EDB AWG & STRANDING NO. OF PAIRS NOM SOLID.30 DB UL ASTM Bare Copper Polyolefin Insulation Corrugated Aluminum / Polymer Tape Shield Paired Conductors Black Sunlight & Water Resistant PE Jacket AERIAL or DIRECT BURIAL Category 5 Powersum Overall Shielded Twisted Pairs (STP) DB AWG & STRANDING NO. OF PAIRS NOM SOLID, Filled DB UL Conductor color code 9. Chart on page 65. 7

75 OUTDOOR APPLICATIONS AERIAL MESSENGER 5MES5 AWG & STRANDING 1/ Galvanized Steel No. OF COND. NOM UL N/A N/A N/A 73

76

77 FIBER OPTIC CABLE Fiber optic cables represent the state of the art in high speed, secure communications. For LANs, WANs, long distance CCTV and integrated security and fire products, fiber optics are the cable of choice. Paige Electric has been a leading supplier of Fiber Optic Products for decades. Using our team of highly trained personnel, Paige can help you choose the most cost effective fiber optic solution. We offer products for indoor / outdoor / aerial / burial / chemical or zero halogen installations. The following pages provide a brief primer on fiber optic cables followed by a sample of some of our most commonly used constructions. 75

78 FIBER OPTIC CABLE BASIC FACTS ADVANTAGES secure transmission RFI/EMI noise immunity Lightning and high voltage interference immunity total electrical isolation wide range of operating temperatures low attenuation high bandwidth small diameter and light weight easy installation custom configurations excellent customer support Optical fiber consists of three basic structures: the core, cladding and coating. Transmission occurs through the glass or plastic core. Light waves are transmitted down the length of the fiber by way of the interaction between the core and the cladding. The cladding provides a lower refractive index at the core interface which causes reflection of light exclusively within the core. Multi-layers of plastic are applied to provide fiber protection. The coating on the glass fibers enables them to be handled and processed into cable form. There are two types of fiber relative to the paths that the light rays, or modes, travel within the fiber core: Fiber Structure Cross Section of Optical Fiber Core Cladding Coating Multimode and single mode. Multimode fiber cores are classified as either step or graded index, depending on the refractive index. Step index multimode fiber has a uniform core and an abrupt change in refractive index at the core/cladding interface. In graded index multimode fiber the core contains many layers of glass, each with a lower index of refraction. 76

79 FIBER OPTIC CABLE BASIC FACTS ADVANTAGES The light modes taking longer paths travel faster than the modes taking the straighter paths. This allows for all the light modes to be received at the same time. The main characteristic of single modefiber is that only a single light light ray, or mode, is transmitted down the core. Since the light pulses do not overlap, distortion is eliminated. Graded index fibers are commercially available with core diameter/ cladding diameters of 50/15, 6.5/15, and 100/10 microns. Single mode fibers have a smaller core, typically 8.5µm, but also have 15µm cladding diameter. Coatings are available from 50 microns to 900 microns. Step Index (Multimode) Core Source Cladding Graded Index (Multimode) Single Mode (Monomode) A Graphic Representation of How Light Rays Travel in Three Fiber Types 77

80 FIBER OPTIC CABLE GLOSSARY OF TERMS Attenuation Loss of signal power between points. In optical cables, attenuation is a ratio of input power vs. output power, measured in decibels per unit length, usually db/km. Backbone A high-speed transmission system used to connect relatively distant points. Backbone networks can be used to join autonomous networks within buildings or between different buildings. Bandwidth The information carrying capacity of a fiber. The bandwidth for a given wavelength is the lowest frequency at which optical power has decreased by 3 db and is expressed in MHz-km. Bend Radius The radius of curvature that an optical fiber cable can bend without causing harmful effects on the optical or mechanical performance of the cable. C h r o m a t i c Dispersion Different wavelengths travel along an optical medium at different speeds. Wavelengths reach the end of the medium at different times, causing the light pulse to spread. This chromatic dispersion is expressed in picoseconds (of dispersion) per kilometer (of length) per nanometer (of source bandwidth). It is the sum of material and waveguide dispersion. Cladding The layer of material, usually glass, that immediately surrounds the fiber core. The cladding is usually coated with another material to provide protection when handling. Core The central part of the glass construction through which light is transmitted. Cut-off Wavelength The wavelength at which a single-mode fiber transmits a single mode of light. Dielectric Non-metallic. All-dielectric designs are inherently non-conductive; all-dielectric cables contain no metal and are lightning resistant. Graded Index A core refractive index profile that varies with the radius of the core. Loss Budget The total acceptable loss for a given system from transmitter to receiver. Includes cables, 78

81 FIBER OPTIC CABLE GLOSSARY OF TERMS splices and connectors. Material Dispersion Pulse dispersion due to the variations in a material s refractive index as a function of wavelength. Microbending Minute but sever bends in fiber that result in light displacement and increased loss. Most microbending can be avoided by the correct selection of materials and proper cabling, handling, and installation techniques. Mode A path of light through a fiber. Mode Field Diameter In single-mode fiber, the region in which light propagates is larger than the glass core diameter. This mode field diameter is a measured value and often listed as a requirement with core diameter in fiber specifications. Numerical Aperture In fiber optics, the sine of half the angle over which a fiber can accept light, it is a function of the relationship between the refractive index of the core and that of the cladding. Optical Time Domain Reflectometer (DTDR) An instrument that measures transmission characteristics of fiber by sending a pulse of light down the fiber and measuring the light scattered across the length and reflected back from the end as a function of time. Used to measure attenuation, point discontinuities and fiber length, as well as to find breaks. Refractive Index The ratio of the speed of light in a vacuum to the speed of light in a material. Also called Index of Refraction. Step Index A refractive index profile characterized by a uniform refractive index within the core and a sharp decrease at the core-cladding interface. Waveguide Dispersion Dispersion caused by the fact that light travels at different speeds in the core and cladding of single-mode fibers. Zero Dispersion Wavelength In single-mode fibers, the wavelength at which the effects of chromatic dispersion and waveguide dispersion are lowest, thus providing the greatest information carrying capacity. 79

82 FIBER OPTIC CABLE PLENUM OFNP 6.5 / 15 Micron Indoor Premise Fiber Multimode Tight Buffered Fiber Aramid Yarns Outer Jacket Indoor Plenum Rated No. of Fibers DESCRIPTION Nom 7DP Circular Premise UP Circular Premise CP Circular Premise CP Circular Premise 0.0 Temperature Range: Operating temperature of F to F Optical Specs ( 850nm / 1300nm ): Max Attenuation Loss: 3.5 / 1. db/km Type. Attenuation Loss: 3.0 / 1.0 db/km Bandwidth (MHz/km): 160 / 500 ( fiber ) 00 / 600(, 6, 1 fiber ) 80

83 FIBER OPTIC CABLE NON-PLENUM Optical Fiber(s) Water Blocking Gel OFNR 6.5 / 15 Micron Indoor / Outdoor Riser Rated Fiber Multimode PVC Jacket Water Blocking Strength Member Buffer Tube Ripcord Indoor / Outdoor Riser Rated No. of Fibers DESCRIPTION Nom 7LV Gel Filled Loose Tube (Single Tube) LV Gel Filled Loose Tube (Single Tube) LV016C Gel Filled Loose Tube (Single Tube) LV06C5 6.5 Gel Filled Loose Tube ( Tubes w/1 fibers ea) Temperature Range: Operating temperature of 0 F to F Optical Specs ( 850nm / 1300nm ): Max Attenuation Loss: 3.5 / 1. db/km Bandwidth (MHz/km): 00 /

84 FIBER OPTIC CABLE PLENUM OFNP 6.5 / 15 Micron Indoor / Outdoor Plenum Rated Fiber Multimode PVC Buffered Fiber Water, Fungus and UV Resistant Polymer Jacket Water Blocked Strength Member Indoor / Outdoor Plenum Rated No. of Fibers DESCRIPTION Nom 7KP Tight Buffered KP Tight Buffered KP Tight Buffered 0.0 7KP Tight Buffered 0.60 Temperature Range: Operating temperature of 0 F to F Optical Specs ( 850nm / 1300nm ): Max Attenuation Loss: 3.5 / 1. db/km Type. Attenuation Loss: 3.0 / 1.0 db/km Bandwidth (MHz/km): 00 / 600 8

85 FIBER OPTIC CABLE Water Blocking Core Ripcord Jacket Non- Hygroscopic Core Wrap Polyethylene Inner Jacket Outdoor Aerial or Burial Fiber 6.5 / 15 Micron Multimode PVC Jacket FRP Dielectric Central Member Torque Balanced Aramid Yarns Gel Filled Loose Buffer Tube Self-Supporting Aerial (ADSS) No. of Fibers DESCRIPTION Nom 7AE0066C All Dielectric AE016C All Dielectric

86 FIBER OPTIC CABLE OUTDOOR AERIAL SUPPORT ACCESSORIES ADSS Hardware & Accessories 7ADEMS8 Description ADSS Mini-Deadend 7AMB8 7ATG755 7AVD656 ADSS Mini-Bracket (for spans up to 00 ) ADSS Tangent / Trunion (for spans over 00 ) ADSS Vibration Damper 7AGW6956 ADSS Tower Guide Clamp 8

Fire Alarm/Life Safety Cable 6

Fire Alarm/Life Safety Cable 6 Electronics Fire Alarm/Life Safety 6 Index Page Alarm and Security Solutions Guide 114-116 Fire alarm systems have expanded from a rather simple and unsophisticated business configured upon large, electromechanical

More information

WIRE & CABLE. Wire & Cable... Wire Accessories...

WIRE & CABLE. Wire & Cable... Wire Accessories... Wire &... Wire Accessories... LINE CARD (9N) Arlington (GI) GRI (WG) Genesis (H2) ICC (Int l Conn & Corp) (RM) Remee (0E) W Box Technologies (WP) West Penn 1.800.233.6261 adiglobal.com/us New Vendor *

More information

WIRE & CABLE. Wire & Cable... Wire Accessories...

WIRE & CABLE. Wire & Cable... Wire Accessories... Wire &... Wire Accessories... LINE CARD (9N) Arlington (GI) GRI (WG) Honeywell Cabling / Genesis (H2) ICC (Int l Conn & Corp) (RM) Remee (0E) W Box Technologies (WP) West Penn 1.800.233.6261 adiglobal.com/us

More information

Quick Reference Applications Guide

Quick Reference Applications Guide Quick Reference Applications Guide General Cable manufactures the most comprehensive line of Carol Brand Electronic Cables available today for signal & data transmission, security, fire alarm & life safety,

More information

Product Guide. Fire Alarm Cables. Initiating Device, SLC Lines, and NAC Cables.

Product Guide. Fire Alarm Cables. Initiating Device, SLC Lines, and NAC Cables. Fire Alarm Cables Initiating Device, SLC Lines, and NAC Cables Product Guide STANDARDS Fire Alarm Systems A fire alarm system is number of devices working together to detect and warn people through visual

More information

Security & Control Cables

Security & Control Cables Security & Control Cables Our multi-conductor cables are manufactured in a wide variety of gauge sizes, shielding configurations and jacketing materials including plenum, riser and general purpose. Applications

More information

NewGeneration Cables. BELDENCable TM

NewGeneration Cables. BELDENCable TM NewGeneration Cables BELDENCable TM Table of Contents New Generation Cables Page No. Introduction 13.2 New Generation Cable Finder Guide 13.3 13.6 Security and Alarm Cable 13.7 13.26 Unshielded Multi-conductor:

More information

Company Profile. We are dedicated to providing our customers competitive price and excellent service.

Company Profile. We are dedicated to providing our customers competitive price and excellent service. 1 Company Profile Hangzhou Kingtone Electronics Co., Limited is a Chinese wire & cable manufacturer specializing in manufacturing Coaxial Cable, Lan Cable, Alarm/Security Cable, Power Cable, Speaker Cable

More information

SOUND/SECURITY FIRE ALARM/LIFE SAFETY TEMPERATURE CONTROLS COAXIAL DATACOM HARDWARE FIBER OPTIC SPECIAL APPLICATION CATALOG, VOL.

SOUND/SECURITY FIRE ALARM/LIFE SAFETY TEMPERATURE CONTROLS COAXIAL DATACOM HARDWARE FIBER OPTIC SPECIAL APPLICATION CATALOG, VOL. CATALOG, VOL. 10 WAREHOUSE / BRANCH LOCATIONS Anaheim, CA Atlanta, GA Boston, MA Phoenix, AZ Portland, OR Seattle, WA Tracy, CA SOUND/SECURITY FIRE ALARM/LIFE SAFETY TEMPERATURE CONTROLS COAXIAL DATACOM

More information

PAIRED UNJACKETED. Insulation Nominal Anixter. Paired Conductors Thickness O.D. Number AWG Strand No. IN IN

PAIRED UNJACKETED. Insulation Nominal Anixter. Paired Conductors Thickness O.D. Number AWG Strand No. IN IN PVC Stranded and Solid Conductors Listed as Misc. Wire PAIRED UNJACKETED Burglar alarm systems wiring; to sensors, control. BURGLAR ALARM 1. CONDUCTOR: Stranded copper conductors (1/c tinned + 1/c bare)

More information

Corra/Clad MC Cable The contractors cable of choice in place of conduit and wire.

Corra/Clad MC Cable The contractors cable of choice in place of conduit and wire. Corra/Clad MC Cable The contractors cable of choice in place of conduit and wire. Installs fast and easy Lowers labor costs Replaces conduit and wire Provides superior grounding UL Listed Corra/Clad MC

More information

Alarm & Security SOLUTIONS. Access Control Video Surveillance Fire Alarm Life Safety

Alarm & Security SOLUTIONS. Access Control Video Surveillance Fire Alarm Life Safety Alarm & Security SOLUTIONS Featuring Gepco Brand s for Lighting Control & Touch Panel Systems Access Control Video Surveillance Fire Alarm Life Safety Home Theater Burglar Alarms Data Communications Video

More information

IDENTIFYING TRAY CABLES FOR YOUR NEXT INSTALLATION A WHITE PAPER

IDENTIFYING TRAY CABLES FOR YOUR NEXT INSTALLATION A WHITE PAPER IDENTIFYING TRAY CABLES FOR YOUR NEXT INSTALLATION A WHITE PAPER Published 3/23/2012 T hough rapidly increasing in popularity, tray cables are still a point of confusion for many. While the term tray cable

More information

SHIELD TYPE MULTICONDUCTOR MULTIPAIR

SHIELD TYPE MULTICONDUCTOR MULTIPAIR CABLE FINDER GUIDE CONDUCTOR SIZE 18 AWG METRIC 0,97mm 2 SHIELD TYPE MULTICONDUCTOR MULTIPAIR Materials Ratings No. of Alpha Page No. of Alpha Page Cable Type Insulation Jacket Temp. Voltage Conductors

More information

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 28 ELEC. SAFETY & SECURITY SECTION CONDUCTORS AND CABLES FOR ELECTRONIC SAFETY AND SECURITY

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 28 ELEC. SAFETY & SECURITY SECTION CONDUCTORS AND CABLES FOR ELECTRONIC SAFETY AND SECURITY SECTION 280513 - CONDUCTORS AND CABLES FOR ELECTRONIC SAFETY AND SECURITY PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Coaxial cabling. 2. RS-232 cabling. 3. RS-485 cabling. 4. Low-voltage control

More information

Genesis. Series Low Voltage Cable. Honeywell Cable Catalog

Genesis. Series Low Voltage Cable. Honeywell Cable Catalog Honeywell Cable Catalog 2011-2012 SECURITY, FIRE, HOME THEATER, SOUND, CCTV, CATV, VOICE AND DATA AND THERMOSTAT WIRE Genesis Series Low Voltage Cable backbone Make no bones about it. Honeywell Genesis

More information

SECTION CONDUCTORS AND CABLES FOR ELECTRONIC SAFETY AND SECURITY

SECTION CONDUCTORS AND CABLES FOR ELECTRONIC SAFETY AND SECURITY SECTION 280513 CONDUCTORS AND CABLES FOR ELECTRONIC SAFETY AND SECURITY PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions

More information

Honeywell Cable & Custom Electronics

Honeywell Cable & Custom Electronics Honeywell Cable & Custom Electronics Genesis Series HVAC/Control Cable ZONE Residential Creating Comfort... Appearance is everything, however, when it comes to HVAC itʼs what you donʼt see that allows

More information

Fire Alarm Cables. Features: Countdown. New Labeling System on box. Color Coded Boxes. Zone and Room Markings

Fire Alarm Cables. Features: Countdown. New Labeling System on box. Color Coded Boxes. Zone and Room Markings Fire Alarm Cables Our Fire Alarm Cables are manufactured in a wide variety of gauge sizes, shielding configurations and jacketing materials including plenum, riser and general purpose. Genesis also manufactures

More information

CORFLEX TYPE MC-HL POWER, CONTROL & INSTRUMENTATION CABLES

CORFLEX TYPE MC-HL POWER, CONTROL & INSTRUMENTATION CABLES CORFLEX TYPE MC-HL POWER, CONTROL & INSTRUMENTATION CABLES CORFLEX TYPE MC-HL POWER, CONTROL & INSTRUMENTATION CABLES INDEX Corflex MC-HL Instrumentation - Pairs and Triads (0V*)... 1 - CORFLEX Cables

More information

CORFLEX. TYPE MC-HL & MV-105 or MC-HL OIL & GAS CABLES

CORFLEX. TYPE MC-HL & MV-105 or MC-HL OIL & GAS CABLES CORFLEX TYPE MC-HL & MV-105 or MC-HL OIL & GAS CABLES INDEX Instrumentation Cables - Pairs and Triads (0V*)... 2 - The Original MC-HL Technology In 1958 Canada Wire and Cable, which s now part of Nexans,

More information

Genesis Cable Audio/Video Product Catalog DELIVERING THE ULTIMATE AUDIO/VIDEO EXPERIENCE

Genesis Cable Audio/Video Product Catalog DELIVERING THE ULTIMATE AUDIO/VIDEO EXPERIENCE Genesis Cable Audio/Video Product Catalog DELIVERING THE ULTIMATE AUDIO/VIDEO EXPERIENCE Bring It Home Our wide range of application-specific cable ensures optimal performance in residential or commercial

More information

Wire and Cable. For more information on these Tyco Electronics products, visit the following website:

Wire and Cable. For more information on these Tyco Electronics products, visit the following website: 26 Wire and Cable Raychem High Performance Wire and Cable....26-2 to 26-4 Madison Cable Products...................26-5 to 26-7 Reference the following cables in Section 15 of this catalog: Premises Networking

More information

BELDEN LOW VOLTAGE COPPER CABLE PLENUM RATED

BELDEN LOW VOLTAGE COPPER CABLE PLENUM RATED ENVIRONMENTAL PRODUCT DECLARATION BELDEN LOW VOLTAGE COPPER CABLE PLENUM RATED At Belden, our core values include customers defining our success, and continuously improving. These are rooted in our culture

More information

Flame Retardant EP/CPE POWER, CONTROL & INSTRUMENTATION CABLES

Flame Retardant EP/CPE POWER, CONTROL & INSTRUMENTATION CABLES Flame Retardant EP/CPE POWER, CONTROL & INSTRUMENTATION CABLES 37-754 FLAME RETARDANT EP/CPE TYPE TC OR TC-ER POWER CABLE Two Five Conductor + Ground (Two, Three & Four Conductor) 600 V Rated 90 C Conductor*

More information

Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design.

Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design. ADDISON Flame Retardant RG59 B/U Coaxial cables Plain copper wire braid PE Solid Bare Copper PVC Outer Sheath APPLICATION The cables are designed for CCTV, security, smoke detection and evacuation monitoring

More information

Home Theater Cables. Your complete solution for high-end audio transmission, stereo, professional audio systems and home theater systems.

Home Theater Cables. Your complete solution for high-end audio transmission, stereo, professional audio systems and home theater systems. Home Theater Cables Your complete solution for high-end audio transmission, stereo, professional audio systems and home theater systems. Home Theater Sound Jacketed Cables Shielded: Twisted Bare Copper

More information

Honeywell Cable. We ve got a cable for that!

Honeywell Cable. We ve got a cable for that! Honeywell Cable We ve got a cable for that! We ve Got a Cable for That! Cables for Intrusion Cables for Video Cables for Access Control Cables for Audio/Video Cables for Fire Cables for Network Cables

More information

Comtran s VITALink 2 Hour Fire Resistive CIC & CI Free Air Cables. Your trusted solution for fire safety

Comtran s VITALink 2 Hour Fire Resistive CIC & CI Free Air Cables. Your trusted solution for fire safety Comtran s VITALink 2 Hour Fire Resistive CIC & CI Free Air Cables Your trusted solution for fire safety When it comes to life and fire safety, trust the experts! Comtran has been a trusted source in the

More information

SECTION CONDUCTORS AND CABLES FOR ELECTRONIC SAFETY AND SECURITY

SECTION CONDUCTORS AND CABLES FOR ELECTRONIC SAFETY AND SECURITY PART 1 - GENERAL 1.1 DESCRIPTION SECTION 28 05 13 CONDUCTORS AND CABLES FOR ELECTRONIC SAFETY AND SECURITY SPEC WRITER NOTE: Use this section only for NCA projects. Delete between // // if not applicable

More information

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards Change History Date Description of Change Pages / Sections Modified Change Approver Initials 8/1/17 Updated section on Manufacturers 3 1. 6/15/16 Updated division section from 16120 to 26 05 00, - mgl44

More information

SAS Security and Alarm Safety Cables

SAS Security and Alarm Safety Cables CABLES Security and Alarm Safety Cables Security and Alarm Safety Cables LOW SMOKE ZERO HALOGEN The right range of cables for modern building installations e-catalogue 203/4 Flexible solutions for commercial,

More information

CATEGORY 6A FTP RJ45 SOLUTION

CATEGORY 6A FTP RJ45 SOLUTION CATEGORY 6A FTP RJ45 SOLUTION Clipsal titanium Patch Cord Clipsal titanium LSZH Patch Cord Clipsal titanium Keystone Jacks Clipsal titanium Modular Jacks Clipsal titanium Patch Panels Clipsal titanium

More information

5. Identification products.

5. Identification products. Essex County College - West Essex Campus Addition And Renovations dib # 54292 / 11-14 [SECTION 260523- CONTROL-VOLTAGE ELECTRICAL POWER CABLES PART 1- GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general

More information

Second Revision No. 601 NFPA [ Section No [Excluding

Second Revision No. 601 NFPA [ Section No [Excluding Second Revision No. 601 NFPA 70 2015 [ Section No. 300.4 [Excluding any Sub Sections] ] Where subject to physical damage, conductors, raceways, and cables shall be protected. Informational Note: Minor

More information

Caledonian Flame Retardant Coaxial Cables

Caledonian Flame Retardant Coaxial Cables Caledonian Flame Retardant Coaxial Cables www.caledonian-cables.co.uk www.addison-cables.com Flame Retardant RG59 Coaxial cables LSZH Outer Sheath Tinned Copper Braid Aluminium+polyester/Aluminium Tape

More information

Comtran Cable. Hub-LINK Cables for Transit Applications

Comtran Cable. Hub-LINK Cables for Transit Applications Comtran Cable Hub-LINK Cables for Transit Applications Overview Hub-LINK rail transit cables are designed to resist the rugged conditions of the underground and at-grade environments, including: Temperature

More information

AFC Cable Systems: the Cable Industry Leader for Over 80 Years

AFC Cable Systems: the Cable Industry Leader for Over 80 Years AFC Cable Systems: the Cable Industry Leader for Over 80 Years AFC Cable Systems, Inc, is proud to announce the launch of two new Type MC cables, MC-Quik and MC-Stat. These two new cables offer the fastest

More information

CAT5E DIRECT BURIAL (FLOODED CORE) 24AWG, UTP, 4 PAIR, SOLID 1000 PULL BOX /CMXF

CAT5E DIRECT BURIAL (FLOODED CORE) 24AWG, UTP, 4 PAIR, SOLID 1000 PULL BOX /CMXF POST CAT5E DIRECT BURIAL (FLOODED CORE) 24AWG, UTP, 4 PAIR, SOLID 1000 PULL BOX PART NUMBER: 059-485/CMXF 1 APPROVALS: MARKETING DATE: THE INFORMATION CONTAINED IN THIS DOCUMENT IS PROPRIETARY TO VERTICAL

More information

CABLES FOR ALARM AND SAFETY SYSTEMS

CABLES FOR ALARM AND SAFETY SYSTEMS CABLES FOR ALARM AND SAFETY SYSTEMS 2 IT S ALL ABOUT RELIABILITY. It is always important to choose high quality cables, especially when it comes to alarms and safety systems. Even small and seemingly insignificant

More information

Genesis Series Cable THE POWER OF CHOICE. Cables for Silent Knight

Genesis Series Cable THE POWER OF CHOICE. Cables for Silent Knight Genesis Series Cable THE POWER OF CHOICE Cables for Silent Knight Cable for That! Genesis Series Cables for Silent Knight 5600 5700 5808 5820XL IFP-25 IFP-50 IFP-100 IFP-1000 IFP-2000 SK-5208 DIRECTORY

More information

Genesis Cable Audio/Video Product Catalog DELIVERING THE ULTIMATE AUDIO/VIDEO EXPERIENCE

Genesis Cable Audio/Video Product Catalog DELIVERING THE ULTIMATE AUDIO/VIDEO EXPERIENCE Genesis Cable Audio/Video Product Catalog DELIVERING THE ULTIMATE AUDIO/VIDEO EXPERIENCE Bring It Home Our wide range of application-specific cable ensures optimal performance in residential or commercial

More information

Compact Module. Category 6A FTP Cabling System 1.1

Compact Module. Category 6A FTP Cabling System 1.1 Updated 24/09/12 Compact Module Cat 6A performance Suitable for 10-Gigabit Ethernet Ultra-slimline design Euro style module Interchangeable with other Euro Modules and blanks Individually QA tested Easy

More information

Fire Alarm Systems ARTICLE. Introduction to Article 760 Fire Alarm Systems. Part I. General

Fire Alarm Systems ARTICLE. Introduction to Article 760 Fire Alarm Systems. Part I. General ARTICLE 760 Fire Alarm Systems Introduction to Article 760 Fire Alarm Systems Article 760 covers the installation of wiring and equipment for fire alarm systems, including all circuits controlled and powered

More information

Multi-Core Fire Resistant Cable

Multi-Core Fire Resistant Cable Fire Resistant Cables / Multi-Core Fire Resistant Cable Approved to UL 444, Zeta ZFP series cables have received UL approval for standard applications. Standards Alarm Cable Z UL 444 Approval CMH Rated

More information

Vista-50P/-50PUL System Design Sheet

Vista-50P/-50PUL System Design Sheet Vista-50P/-50PUL System Design Sheet INTRUSION DETECTION HOLD UP CRITICAL EQUIP. SUPV. LONG RANGE RADIO ACCESS CONTROL SECTION 1: Basic Vista-50P (Nine Hardwired Zones, One Addressable Loop, Wireless)

More information

CIR CRUSH & IMPACT RESISTANT ARCTIC GRADE OIL & GAS CABLES

CIR CRUSH & IMPACT RESISTANT ARCTIC GRADE OIL & GAS CABLES CIR CRUSH & IMPACT RESISTANT ARCTIC GRADE OIL & GAS CABLES Gexol CIR ARCTIC GRADE (AG) Crush and Impact Resistant Without External Armoring Passes the same stringent crush and impact testing required by

More information

CIR AG Power Cables. CIR AG Control Cable. CIR Type VFD Cable. CIR AG Ratings & Approvals. n UL Listed as Type TC-ER n UL Listed as TC-ER-HL (E123629)

CIR AG Power Cables. CIR AG Control Cable. CIR Type VFD Cable. CIR AG Ratings & Approvals. n UL Listed as Type TC-ER n UL Listed as TC-ER-HL (E123629) Gexol CIR ARCTIC GRADE (AG) Crush and Impact Resistant Without External Armoring Passes the same stringent crush and impact testing required by UL 2225 for Type MC-HL n Shortest Lead Times Standard 8-10

More information

(800) 292- omnicable.com CABLE ACCESSORIES GUIDE

(800) 292- omnicable.com CABLE ACCESSORIES GUIDE CABLE ACCESSORIES GUIDE SECTION PAGES Heat-Shrink Joints 1 Cold Shrinkable Joints 2 Heat-Shrink Terminations 3 Tool Free Terminations 4 Modification Kits for 3-Conductor Cable 5 MV Splice & Termination

More information

Vista-10SE System Design Sheet

Vista-10SE System Design Sheet Vista-10SE System Design Sheet INTRUSION DETECTION HOLD UP CRITICAL EQUIP. SUPV. LONG RANGE RADIO SECTION 1: Basic Vista-10SE -Features QED programming for quick enrollment of devices Part No. Qty. Each

More information

Category 5 Premise Wire

Category 5 Premise Wire Category 5 Premise Wire engineered with you in mind Features Copper and Fiber Optic Cable Manufacturer U.S. Manufacturer State-of-the-Art Quality Labs ISO9001 Accredited Standard and Extended Warranties

More information

CIR CRUSH & IMPACT RESISTANT OIL & GAS CABLES

CIR CRUSH & IMPACT RESISTANT OIL & GAS CABLES CIR CRUSH & IMPACT RESISTANT OIL & GAS CABLES Gexol CIR Crush and Impact Resistant Without External Armoring Passes the same stringent crush and impact testing required by UL 2225 for Type MC-HL Index

More information

MEDIUM, LOW AND CONTROL VOLTAGE CABLES

MEDIUM, LOW AND CONTROL VOLTAGE CABLES Related Sections U-M Design Guideline Sections: 260800 - Electrical Acceptance Tests Products Medium Voltage Primary Cables Primary power distribution cable shall be single conductor stranded copper, with

More information

Vista-20SEUL System Design Sheet

Vista-20SEUL System Design Sheet System Design Sheet INTRUSION DETECTION HOLD UP CRITICAL EQUIP. SUPV. LONG RANGE RADIO SECTION 1: Basic -Features QED programming for quick enrollment of devices (Eight Hardwired Zones, Wireless) Part

More information

Caledonian Fire resistant Coaxial Cables

Caledonian Fire resistant Coaxial Cables Caledonian Fire resistant Coaxial Cables www.caledonian-cables.net www.addison-cables.com Fire resistant rg59 b/u Coaxial Cables RG59 B/U FR LSZH Sheath Fire Resistant Tape Copper Clad Steel/Bare Copper

More information

Flexible Power Cable DLO

Flexible Power Cable DLO 37-119 Flexible Power Cable DLO 2000 Volts 90 C Diesel Locomotive Cable Limited Smoke (Sizes 2/0 and higher) EP/CPE RHH, RHW-2 Flexible-stranded, tin-coated annealed copper Flame retardant, oil and sunlight

More information

Print Specification. Publication. Instructions. Specific requirements. General requirements

Print Specification. Publication. Instructions. Specific requirements. General requirements Print Specification Publication GSA-CC1 Single Input Signal Module Installation Sheet P/N P-047550-1802-EN REV 04 ISS 23JUN15 Instructions This page is the print specification for the publication. It is

More information

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017 SECTION 26 0519 LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions

More information

SECTION (13740) - VIDEO SURVEILLANCE

SECTION (13740) - VIDEO SURVEILLANCE PART 1 GENERAL 1.01 SUMMARY A. Section Includes: SECTION 28 23 00 (13740) - VIDEO SURVEILLANCE 1. CCTV Closed Circuit Television System. B. Related Sections:. 1.02 REFERENCES 1. Section 26 05 00 (16050)

More information

2016 CDM Smith All Rights Reserved July 2016 SECTION FIBER OPTIC DATA NETWORK

2016 CDM Smith All Rights Reserved July 2016 SECTION FIBER OPTIC DATA NETWORK PART 1 GENERAL 1.01 SCOPE OF WORK SECTION 27 12 23 FIBER OPTIC DATA NETWORK A. Furnish, install, terminate, and test all fiber optic equipment and cabling necessary for a complete and functional data highway

More information

Catalogue Telecommunication Cables INTRODUCCIÓN

Catalogue Telecommunication Cables INTRODUCCIÓN Catalogue Telecommunication Cables INTRODUCCIÓN Conductores Tecnológicos S.A. www.contecsa.es Index of Cables Page Introduction 3 EAP / EAP-R 4 EAPSP / EAPSP-R 5 ISP / ICP 6 Conductores Tecnológicos S.A.

More information

Belden Infinity C-TC+ Cables for Extreme Flexing

Belden Infinity C-TC+ Cables for Extreme Flexing Product Bulletin PB 0 Belden Infinity Cables These highly flexible control, power, video and data cables handle the rigorous speeds and near-constant motion of C-track systems, robots, pick-and-place machines,

More information

PHOTOVOLTAIC CABLES. Photovoltaic Cable 2000V/1500V Photovoltaic Cable 2000V/1000V

PHOTOVOLTAIC CABLES. Photovoltaic Cable 2000V/1500V Photovoltaic Cable 2000V/1000V PHOTOVOLTAIC CABLES PHOTOVOLTAIC CABLES INDEX n AmerSol Dual-Certified (UL / ETL) Photovoltaic Cable 2000V/1500V....................... 2-3 n AmerSol Dual-Certified (UL / ETL) Photovoltaic Cable 2000V/1000V.......................

More information

Vista-128FB System Design Sheet

Vista-128FB System Design Sheet Vista-128FB System Design Sheet FIRE DETECTION SPRINKLER SUPERVISION INTRUSION DETECTION HOLD UP CRITICAL EQUIP. SUPV. LONG RANGE RADIO ACCESS CONTROL SECTION 1: Basic Vista-128FB (Eight Hardwired Zones,

More information

Brand Portable Power Cord & Control Cable Solutions

Brand Portable Power Cord & Control Cable Solutions Carol Brand Portable Power Cord & Control Cable Solutions for the Entertainment Market General Cable s Carol Brand portable power cord and control cable solutions are manufactured for use in the entertainment

More information

.2 Section Waste Management and Disposal..4 Section Electrical General Requirements.

.2 Section Waste Management and Disposal..4 Section Electrical General Requirements. Issued 2005/06/01 Section 13704 Video Surveillance Page 1 of 10 PART 1 GENERAL 1.1 SECTION INCLUDES.1 Video cameras..2 Video handling..3 Recording devices..4 Transmission methods. 1.2 RELATED SECTIONS.1

More information

Texas Based UL Alarm System Monitoring. Alarm System Monitoring Up to 128 zones $34.95 per month 25.00% $26.22

Texas Based UL Alarm System Monitoring. Alarm System Monitoring Up to 128 zones $34.95 per month 25.00% $26.22 Specification MAINTENANCE & MONITORING Texas Based UL Alarm System Monitoring Requires a phone line for communications, less options available and cell back up available Alarm System Monitoring Up to 128

More information

SIGA-CC1 Single Input Signal Module Installation Sheet

SIGA-CC1 Single Input Signal Module Installation Sheet SIGA-CC1 Single Input Signal Module Installation Sheet Personality codes Use the personality codes described below to configure the SIGA-CC1 module. See Table 1 for listing information Table 1: Personality

More information

SECTION COMMUNICATIONS PATCH CORDS, STATION CORDS AND CROSS CONNECT WIRE

SECTION COMMUNICATIONS PATCH CORDS, STATION CORDS AND CROSS CONNECT WIRE SECTION 27 16 19 COMMUNICATIONS PATCH CORDS, STATION CORDS AND CROSS CONNECT WIRE PART 1 GENERAL 1.01 DESCRIPTION A. The work covered by this section of the Specifications includes all labor necessary

More information

B. Configuration of system shall be through Schneider Electric in Homewood, Illinois (Jerry Lanfear ).

B. Configuration of system shall be through Schneider Electric in Homewood, Illinois (Jerry Lanfear ). SECTION 28 13 00 - ACCESS CONTROL PART I - GENERAL 1.1 SUMMARY A. This specification section describes the furnishing, installation, commissioning, and programming of a complete, turnkey, hardwired Andover

More information

SECTION ELECTRICAL IDENTIFICATION

SECTION ELECTRICAL IDENTIFICATION SECTION 16075 - ELECTRICAL IDENTIFICATION PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

TAA COMPLIANT. 15Year Limited Warranty. 1Year Limited Warranty. 25Year Limited Warranty. Intertek. Intertek SPECIAL STANDARD EXTENDED

TAA COMPLIANT. 15Year Limited Warranty. 1Year Limited Warranty. 25Year Limited Warranty. Intertek. Intertek SPECIAL STANDARD EXTENDED ATALOG Our Mission: Since its creation in 006 Vertical able has been a leader in supplying low voltage cables, connectivity products and accessories. Vertical able is internationally recognized for bringing

More information

commercial-type cabling and connectivity products into the industrial landscape.

commercial-type cabling and connectivity products into the industrial landscape. Product Bulletin PB 315 Belden DataTuff Industrial Ethernet Connectivity, Tools & Accessories Belden DataTuff Cat 6 and 5e IP67/IP20 Cord Sets, IP67 Modular Jacks, IP67 Plug Kits, Cabling Accessories and

More information

SECTION LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES (600 VOLTS AND BELOW)

SECTION LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES (600 VOLTS AND BELOW) SECTION 26 05 21 PART 1 - GENERAL 1.1 DESCRIPTION This section specifies the furnishing, installation, and connection of the low voltage power and lighting wiring. 1.2 RELATED WORK A. Excavation and backfill

More information

Oberon s National Electric Code (NEC)Compliance Statement and Underwriters Laboratories (UL ) Considerations for Oberon Products

Oberon s National Electric Code (NEC)Compliance Statement and Underwriters Laboratories (UL ) Considerations for Oberon Products Oberon s National Electric Code (NEC)Compliance Statement and Underwriters Laboratories (UL ) Considerations for Oberon Products Manufacturers Statement of Compliance with NFPA 70, National Electric Code,

More information

SECTION COMMUNICATIONS HORIZONTAL CABLING

SECTION COMMUNICATIONS HORIZONTAL CABLING SECTION 27 15 00.19 COMMUNICATIONS PART 1 - GENERAL 1.1 SUMMARY A. Section includes the following: 1. Category 6 and Category 5e horizontal UTP cabling. 2. Cable connecting hardware, patch panels, patch

More information

COMMON WORK RESULTS FOR ELECTRICAL: Basic Electrical Materials Methods

COMMON WORK RESULTS FOR ELECTRICAL: Basic Electrical Materials Methods 1. BASIC ELECTRICAL MATERIALS 1. All conduit and raceway must be 3/4" or larger. Exposed raceway in finished areas shall be in 700 or larger wiremold. Exception: runs to individual devices 10 or less,

More information

E3 Series Broadband System

E3 Series Broadband System Voice Evacuation E3 Series Broadband System Intelligent, Networked, Multi-Channel Fire Alarm Control and Emergency Voice Evacuation System General The, E3 Series Broadband System is a modular design and

More information

4120 Fire Alarm Network Reference

4120 Fire Alarm Network Reference 4120 Fire Alarm Network Reference Features Autocall 4120 Fire Alarm Network communications are available for wired or fiber optic connections Wired communications are available on Network Interface Cards

More information

System Accessories, LCD Annunciators

System Accessories, LCD Annunciators System Accessories, LCD Annunciators UL, ULC Approved* A4606 Series Color Touchscreen LCD Annunciators for 4007ES Fire Alarm Control Panels Features Fig 1: A4606-9202 LCD Annunciator with Red Trim Fig

More information

C6 Premium. C6 Premium Copper Systems from Infinique is premium performing Class E / Category 6 Data Communication

C6 Premium. C6 Premium Copper Systems from Infinique is premium performing Class E / Category 6 Data Communication Stable and Reliable Data Communication Solutions from Infinique Infinique provides high quality end-to-end solutions for communication infrastructure that bring great value to its customers. We have achieved

More information

13. UNITED KINGDOM Standards Supply Voltage and Plug Configurations 247

13. UNITED KINGDOM Standards Supply Voltage and Plug Configurations 247 13. UNITED KINGDOM 13.1 Standards 13.1.1 BSI 240 13.1.2 BASEC 242 13.1.3 BBC 242 13.1.4 BNFL 242 13.1.5 BRB 242 13.1.6 British Telecom 243 13.1.7 Department of the Environment 243 13.1.8 Department for

More information

Wire and Cable The Industry Standard for Rugged, Reliable Performance

Wire and Cable The Industry Standard for Rugged, Reliable Performance Wire and Cable The Industry Standard for Rugged, Reliable Performance TE Connectivity A Powerful Source Pushing the Performance Envelope As one of the world s largest suppliers of passive electronic components

More information

Special Provision No. 683S28 December 2017

Special Provision No. 683S28 December 2017 FIBRE OPTIC COMMUNICATION CABLES, AERIAL ON MESSENGER CABLE - Item No. FIBRE OPTIC COMMUNICATION CABLES, AERIAL ON MESSENGER CABLE (TEMPORARY) - Item No. Special Provision No. 683S28 December 2017 1. SCOPE

More information

FEB. 17 Rev. A1

FEB. 17 Rev. A1 Product Specification 108-94552 10 FEB. 17 Rev. A1 The product described in this document has not been fully tested to ensure conformance to the requirements outlined below. Therefore, TE Connectivity

More information

IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission

IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission ADDISON Flame Retardant CAT5e Data Cables FTX-CAT5e U/UTP4P24 FTX-CAT5e f/utp4p24 FTX-CAT5e sf/utp4p24 LSZH Outer Aluminium/Polyester Tape Solid Copper Conductor PE Insulation Tinned Copper Drain Wire

More information

SECTION 2 NEC REFERENCES SECTION 1 LOW-VOLTAGE AND POWER- LIMITED SYSTEMS...1. CHAPTER 1 GENERAL Introduction...35

SECTION 2 NEC REFERENCES SECTION 1 LOW-VOLTAGE AND POWER- LIMITED SYSTEMS...1. CHAPTER 1 GENERAL Introduction...35 SECTION 1 LOW-VOLTAGE AND POWER- LIMITED SYSTEMS...1 Overview of Low-Voltage and Power-Limited Systems...3 Chapter 4 Equipment for General Use...3 Chapter 5 Special Occupancies...3 Chapter 6 Special Equipment...4

More information

. SECTION CONTROL-VOLTAGE ELECTRICAL POWER CABLES

. SECTION CONTROL-VOLTAGE ELECTRICAL POWER CABLES . SECTION 260523 - CONTROL-VOLTAGE ELECTRICAL POWER CABLES PART I - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and

More information

STANDARD FOR INDOOR-OUTDOOR OPTICAL FIBER CABLE

STANDARD FOR INDOOR-OUTDOOR OPTICAL FIBER CABLE ANSI/ICEA S-104-696-2001 STANDARD FOR INDOOR-OUTDOOR OPTICAL FIBER CABLE Publication S-104-696 First Edition - September 2001 Published By Insulated Cable Engineers Association, Inc. Post Office Box 1568

More information

SECTION INTRUSION DETECTION SYSTEM

SECTION INTRUSION DETECTION SYSTEM SECTION 13845 INTRUSION DETECTION SYSTEM PART 1 GENERAL 1.01 SUMMARY A. Section Includes: A complete, operable, tested intrusion detection system, bearing Underwriters Laboratories (UL) mercantile listing

More information

Fee $15 Course: NEC Changes 5 This course is valid for these credentials: Credential Description Cred Code Credit Hours

Fee $15 Course: NEC Changes 5 This course is valid for these credentials: Credential Description Cred Code Credit Hours www.garyklinka.com Page 1 of 9 Instructions: Fee $15 1. Print these pages. 2. Circle the correct answers and transfer them to the answer sheet. 3. Page down to the last page for the verification forms

More information

A. Product Data: For each electrical identification product indicated. B. Comply with 29 CFR and 29 CFR

A. Product Data: For each electrical identification product indicated. B. Comply with 29 CFR and 29 CFR September 2012, rev. 00 26 0553 Identification for Electrical Systems PART 1. GENERAL 1.01 Summary A. Section Includes: 1.02 Submittals 1. Identification for raceways. 2. Identification of power and control

More information

Oberon s NEC Compliance Statement and Underwriters Laboratories (UL ) Considerations for Oberon Products

Oberon s NEC Compliance Statement and Underwriters Laboratories (UL ) Considerations for Oberon Products Oberon s NEC Compliance Statement and Underwriters Laboratories (UL ) Considerations for Oberon Products Manufacturers Statement of Compliance with NFPA 70, National Electric Code Oberon s suspended ceiling

More information

High Performance LSZH Fire Resistant Cable

High Performance LSZH Fire Resistant Cable High Performance LSZH Fire Resistant Cable www.cavicel.com 104/2 FIRECEL SR 114H is the long and well established CAVICEL fire resistant cable in the market, since many years. These cables are third party

More information

E3 Series Broadband System

E3 Series Broadband System Broadband System Description The, Broadband System includes the NetSOLO Broadband System. Like the Net- SOLO Broadband System, the Broadband is of modular design and allows a wide range of configurations

More information

Telecommunication Cables

Telecommunication Cables Telecommunication Cables Telecommunication Cables Introduction 3 EAP / EAP-R 4 EAPSP / EAPSP-R 5 ISP / ICP 6 Page ELECWIRES 2 www.elecwires.es INTRODUCCIÓN Telecommunication Cables Telephone cables suitable

More information

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 27 COMMUNICATIONS SECTION PUBLIC ADDRESS AND MASS NOTIFICATION SYSTEMS

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 27 COMMUNICATIONS SECTION PUBLIC ADDRESS AND MASS NOTIFICATION SYSTEMS SECTION 275116 - PUBLIC ADDRESS AND MASS NOTIFICATION SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Preamplifiers. 2. Power amplifiers. 3. Microphones. 4. Control console. 5. Loudspeakers.

More information

NEC 2017 Changes and Their Effect Upon the ICT Industry

NEC 2017 Changes and Their Effect Upon the ICT Industry NEC 2017 Changes and Their Effect Upon the ICT Industry Today s Presenters John Kacperski, RCDD, OSP, CDT Chair of BICSI Standards BICSI Representative on NFPA 70-CMP 16 Richard S. Anderson, RCDD, CDT,

More information

E3 Series Broadband. Description. Features. Intelligent, Networked, Multi-Channel Fire Alarm Control and Emergency Voice Evacuation System

E3 Series Broadband. Description. Features. Intelligent, Networked, Multi-Channel Fire Alarm Control and Emergency Voice Evacuation System Broadband Description Intelligent, Networked, Multi-Channel Fire Alarm Control and Emergency Voice Evacuation System The Broadband System includes the Net- SOLO Broadband System. Like the NetSOLO Broadband

More information

Speedlock AMC Connectors...KA1. Armored Cable Connectors...KB1-KB5 Metal Clad Cable Connectors...KB1-KB5 Flexible Metal Conduit Connectors...

Speedlock AMC Connectors...KA1. Armored Cable Connectors...KB1-KB5 Metal Clad Cable Connectors...KB1-KB5 Flexible Metal Conduit Connectors... SECTION K INDEX Product Description Page Number Speedlock AMC Connectors............................KA Armored Cable Connectors...........................KB-KB5 Metal Clad Cable Connectors.........................KB-KB5

More information