THE SMOKE MUST GO. Consulting - Project Planning - Supply - Installation - Service

Size: px
Start display at page:

Download "THE SMOKE MUST GO. Consulting - Project Planning - Supply - Installation - Service"

Transcription

1 THE SMOKE MUST GO Consulting - Project Planning - Supply - Installation - Service Brandschutz-Technik und Rauchabzug GmbH Langbehnstraße 13 D Hamburg, Germany Telefon +49(0) Telefax +49(0) info@btr-hamburg.de

2 Our products are QS approved All products of our product range are subject to a continual quality control process during production. A standardised pre-delivery check is performed prior to shipment. Development, production, shipping and our well-known competent After Sales Service are subject to the stringent requirements of DIN EN ISO BTR Group has been certified according to DIN EN ISO 9001 for years. Compliance with the requirements of the standard are regularly verified by VdS Schadenverhütung (A company of the German Insurance Association GDV). Products requiring CE conformity in accordance with applicable regulations are identified with the CE symbol. Declarations of conformity are available for all affected products and can be obtained upon request. The BTR Group The BTR Group has been active in the problem area of smoke vent systems for many decades. Development, production, supply and service, especially of electric motor driven smoke vent systems, are the main focus of our activities. We are also well known for the development of special solutions in the area of smoke extraction, regardless whether the demand concerns electrical, pyrotechnical or pneumatic actuation. An important aspect of our field of activity is training and education of our staff, not only concerning products, but also in regard to service and commissioning. Our partner organisations in Germany and abroad are at your service with advice and support, in order to meet any fire protection requirement in the interest of the customer as well as safety. Our experienced engineers are available to solve your particular problems.

3 Danger by flue gases/consequential damages Fire casualties are smoke casualties. Smoke from a fire consists of a mix of complete and incomplete combustion. Depending on the nature of the source of the fire, the smoke is mixed with solid particles and soot particles. There are two possible causes for death by asphyxiation: 1. The smoke of the fire contains lethal toxic components. These may, depending on their concentration and type, result in death within a very short time. 2. The smoke of the fire contains so-called corrosive components. Inhalation of these substances causes causticization (burning) of the lungs and respiratory tract. In most cases, the interaction of both causes is the reason for smoke poisoning and serious internal injuries of fire victims. The consequences are permanent injuries or death of fire victims. Propagation of smoke without and with a smoke vent system Fire victims as a consequence of direct contact with fire are relatively rare. However, this type of risk increases, if there is an uncontrolled blazing fire due to the absence of smoke and heat extraction systems. Flue gas volumes created by fires Almost any type of combustion results in the creation of more or less toxic flue gases. The diagram at right shows the enormous volumes of flue gases that may be created within a very short time during the combustion of various building materials. Particularly building materials that are used for heat or sound insulation are giving off very high volumes of flue gas during combustion. Rooms or buildings without a smoke vent system can be completely filled with smoke within minutes. One example: A staircase with a floor space of 16 m 2 and a height of 15 metres is completely filled with smoke and conflagration gases more than 100 times with the combustion of just 10 kg of foam rubber. Fumes, conflagration gases and smoke development with combustion of 10 kg of material.

4 Electric motor driven skylight Smoke vent system control panel Electric motor driven window Smoke vent button on top floor Smoke vent button on ground floor Example: Staircase smoke vent system Smoke extraction systems designed by BTR provide smoke-free escape routes and secure access for the fire brigade, resulting in the preservation of life and property as well as limiting fire damage.

5 Smoke extraction and ventilation systems with electric motor driven actuation Utilisation: Smoke vent systems in staircases, meeting halls and other buildings, in accordance with German building regulation: Advantages/features: High level of operational security due to certified products. Daily ventilation with any desired flap opening position possible. Functional security in case of 230 V mains power failure through built-in emergency batteries. Electrical integration with other systems possible. Attractively designed actuators and drives. Connection to nearly all types of flaps, windows and skylights possible. Low maintenance, hardly any consumables in the course of maintenance or wilful actuation.

6 Smoke vent buttons Smoke vent buttons are pressed in an emergency to manually trigger an electric motor driven smoke vent system. In accordance with the locally applicable building regulation, one or multiple smoke vent buttons are required. They are available in the approved colours orange, grey, blue and yellow. A hidden Reset button can be used to reset the smoke vent system after it has been triggered in an emergency. Control panels The smoke vent system control panel receives external signals and commands, processes these and controls the 24 V motorised actuators of the smoke vent system. The control panel houses the power supply, control system, terminal strips, battery charging devices and two maintenance-free emergency power batteries. The smoke vent system control panels are offered in compact design units for standard systems, for example, in staircases, and in modular design for custom-tailored applications, for example, for glass facades in shopping centres. Motors The attractively styled 24 V motorised actuators are suitable for all common types of flaps and wings. The range of products includes motors with a stroke of up to 1000 mm and lifting power of up to 1000 N. The motor housings can be painted in any available RAL colour. A wide range of brackets is also available.

7 Chain drives 24 V chain drives are used to satisfy the highest demands on visual appearance, while at the same time assuring compliance with building regulations. These attractively styled motors come with a stroke of up to 600 mm and lifting power of up to 400 N. They are predominantly used with sash and top-hung sash windows. Automatic wind-rain actuation In connection with the operating mode for daily ventilation, it is possible to automatically close the smoke vent system by means of an automatic wind-rain actuator. Naturally, an alarm case will continue to have priority. The point of closure is adjustable.

8 Smoke vent systems protect life and property Smoke vent drives on window sashes provide not just security, but are also attractively styled and come with the added daily ventilation function. Control Sensors Detectors Drives Accessories Your authorized distributor: BTR Brandschutz-Technik und Rauchabzug GmbH Langbehnstraße 13 D Hamburg, Germany Tel. +49(0) Fax +49(0)

Performance Specifications LSF LIFT-SMOKE-FREE

Performance Specifications LSF LIFT-SMOKE-FREE Performance Specifications LSF LIFT-SMOKE-FREE Lift shafts and machinery rooms must be ventilated and equipped with a smoke and heat exhaust ventilation (SHEV) system in accordance with the currently valid

More information

Smoke ventilation. Complete smoke ventilation solutions for all building types

Smoke ventilation. Complete smoke ventilation solutions for all building types Smoke ventilation Complete smoke ventilation solutions for all building types Passive smoke ventilation utilises natural driving forces for the efficient and rapid exhaust of smoke and heat from burning

More information

Interaction of Water Extinguishing Systems and Smoke and Heat Exhaust Ventilation Systems (SHEVS)

Interaction of Water Extinguishing Systems and Smoke and Heat Exhaust Ventilation Systems (SHEVS) Fire Protection Leaflet Interaction of Water Extinguishing Systems and Smoke and Heat Exhaust Ventilation Systems (SHEVS) 0 General Regulations and recommendations missing from this leaflet do not entitle

More information

Compact power supply unit THZ Comfort

Compact power supply unit THZ Comfort GEZE PRODUCT NEWS WINDOW TECHNOLOGY Compact power supply unit THZ Comfort Compact power supply unit THZ Comfort Staircase control unit especially designed for installation in visible areas with 3,4 A and

More information

Branch Solution Wood based panel plants. Fire protection solutions for wood based panel plants

Branch Solution Wood based panel plants. Fire protection solutions for wood based panel plants Branch Solution Wood based panel plants Fire protection solutions for wood based panel plants afety throughout the production process R The versatility of wood as a raw material and the fact that it is

More information

Operating Instructions!

Operating Instructions! Operating Instructions! 3 4 Oscillation MO 16.2 / MO 40 Example 3 4 MO 16.2 The unit has to be strictly used according to the instruction manual. Keep the unit away from children and from persons not instructed

More information

CO 2 EXTINGUISHING SYSTEMS

CO 2 EXTINGUISHING SYSTEMS CO 2 EXTINGUISHING SYSTEMS CO 2 THE FIRE EXTINGUISHING CLASSIC: CLEAN, FAST AND RELIABLE TOTAL WALTHER, the acknowledged specialist in fire protection systems, has been manufacturing CO 2 extinguishing

More information

automatic FiReFighTing SYSTeMS in PainT booths

automatic FiReFighTing SYSTeMS in PainT booths SPECIAL HAZARDS PROTECTION automatic FiReFighTing SYSTeMS in PainT booths hazard type The risks considered, according to existing regulations, are Class A risk: solids fire. Class B risk: fire of flammable

More information

AUTOMATIC FIREFIGHTING SYSTEMS IN PAINT BOOTHS

AUTOMATIC FIREFIGHTING SYSTEMS IN PAINT BOOTHS SPECIAL HAZARDS PROTECTION AUTOMATIC FIREFIGHTING SYSTEMS IN PAINT BOOTHS Hazard type The risks considered, according to existing regulations, are Class A risk: solids fire. Class B risk: fire of flammable

More information

ELECTRONIC PARTS - CATALOGUE

ELECTRONIC PARTS - CATALOGUE Smoke and Heat Ventilation Pneumatic - Electronic Control Systems K + G Pneumatik GmbH In der Krause 48 52249 Eschweiler Germany. +49 (0) 24 03 / 99 50-0 ; +49 (0) 24 03 / 655 30 Grasl Pneumatic-Mechanik

More information

FIREJET V / 48V SMOKE SYSTEMS CE EN CERTIFIED

FIREJET V / 48V SMOKE SYSTEMS CE EN CERTIFIED COXDOME. FIRE JET SMOKE SYSTEMS FIREJET 165 24V / 48V SMOKE SYSTEMS CE EN12101-2 CERTIFIED DRIVEN BY DAYLIGHT WWW.JET-COX.CO.UK IN THE CASE OF A FIRE WITHIN A BUILDING MORE THAN 90% OF FATALITIES ARE CAUSED

More information

ROLL-DOWN FIRE DOORS AND SMOKE CURTAINS

ROLL-DOWN FIRE DOORS AND SMOKE CURTAINS ROLL-DOWN FIRE DOORS AND SMOKE CURTAINS WHEN IN NEED, CHAMPION DOOR FIRE IS THE ANSWER Champion Door Fire is a domestic specialist solution for properties where doors must conform to fire safety standards.

More information

Version 3 Controls for smoke and natural ventilation. CompactSmoke WSC 310 / WSC 320 STANDARD Smoke control panel 10-20A

Version 3 Controls for smoke and natural ventilation. CompactSmoke WSC 310 / WSC 320 STANDARD Smoke control panel 10-20A Version 3 Controls for smoke and natural ventilation CompactSmoke WSC 310 / WSC 320 STANDARD Smoke control panel 10-20A 1.50 Application smoke extraction and daily comfort ventilation 2 smoke / 2 daily

More information

Type FKS-EU COMPACT DIMENSIONS, IDEAL FOR RESTRICTED SPACES. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FKS-EU

Type FKS-EU COMPACT DIMENSIONS, IDEAL FOR RESTRICTED SPACES. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FKS-EU Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FKS-EU Type FKS-EU COMPACT DIMENSIONS, IDEAL FOR RESTRICTED SPACES Small rectangular fire damper for the isolation of duct penetrations

More information

Operating instructions

Operating instructions Operating instructions Gas-fired condensing boiler Logano plus GB312 For the user Please read carefully before use 7 747 009 296-01/2007 EN Contents 1 For your safety..............................................

More information

USER S INFORMATION MANUAL

USER S INFORMATION MANUAL USER S INFORMATION MANUAL UPFLOW/HORIZONTAL & DOWNFLOW TWO STAGE INDUCED DRAFT GAS FURNACES Recognize this symbol as an indication of Important Safety Information If the information in this manual is not

More information

Protect Safety Alarms

Protect Safety Alarms Safety Alarms Product Catalogue 2018 Protect Safety Alarms Deta s new range of interlinkable mains powered Smoke and Heat Alarms satisfy all Grade D domestic requirements as laid down by BS 5839: Part

More information

Type FK-EU FOR DIVERSE APPLICATIONS. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FK-EU

Type FK-EU FOR DIVERSE APPLICATIONS. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FK-EU Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FK-EU Type FK-EU FOR DIVERSE APPLICATIONS Rectangular fire damper for the isolation of duct penetrations between fire compartments,

More information

VdS Guidelines CONTENTS

VdS Guidelines CONTENTS CONTENTS Fire Protection Operational Fire Protection Basics Plant Equipment Hot Works Structual Fire Protection Electrical Installations Systems and Components Fire Protection Concepts for special Sectors

More information

D+H EURO-SHEV: Smoke ventilation according to DIN EN

D+H EURO-SHEV: Smoke ventilation according to DIN EN D+H EURO-SHEV: Smoke ventilation according to DIN EN 12101-2 2 INTRODUCTION Since September 2006, all natural smoke and heat exhaust ventilators (NSHEVs) must provide usability certification in accordance

More information

Type FKRS-EU COMPACT DIMENSIONS, IDEAL FOR RESTRICTED SPACES. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FKRS-EU

Type FKRS-EU COMPACT DIMENSIONS, IDEAL FOR RESTRICTED SPACES. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FKRS-EU Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FKRS-EU Type FKRS-EU COMPACT DIMENSIONS, IDEAL FOR RESTRICTED SPACES Small circular fire damper for the isolation of duct penetrations

More information

mcr PROLIGHT, mcr PROLIGHT PLUS

mcr PROLIGHT, mcr PROLIGHT PLUS mcr PROLIGHT, mcr PROLIGHT PLUS smoke exhaust vents, skylights, roof access hatches The fire causes the release of large amounts of smoke and hot gases in the building that can be dangerous for people

More information

Technologies Gas extinguishing systems. MX 1230 Fire Extinguishing Systems Fighting Fire using 3M Novec 1230

Technologies Gas extinguishing systems. MX 1230 Fire Extinguishing Systems Fighting Fire using 3M Novec 1230 Technologies Gas extinguishing systems MX 1230 Fire Extinguishing Systems Fighting Fire using 3M Novec 1230 ire protection Efficient and compact MX 1230 fire extinguishing systems fight fires using Novec

More information

Who are we? LGF SYSMAC a 15 Years Young and Vibrant Company Characterized by

Who are we? LGF SYSMAC a 15 Years Young and Vibrant Company Characterized by Automated Opening Who are we? LGF SYSMAC a 15 Years Young and Vibrant Company Characterized by Young and dynamic leadership Customer centric approach Constant improvement through innovative and out-of-the-box

More information

Operating Instructions

Operating Instructions Operating Instructions Typ TEKA CAREMASTER TEKA Absaug- und Entsorgungstechnologie GmbH Industriestraße 13 D-46342 Velen Postfach 1137 D-46334 Velen Tel.: +49 (0) 2863 9282-0 Fax: +49 (0) 2863 9282-72

More information

MBZ300. Emergency power control unit. GB Installation instructions MBZ300 MBZ300 MBZ300 MBZ300 MBZ300 MBZ300 MBZ300 PME PME. Reset.

MBZ300. Emergency power control unit. GB Installation instructions MBZ300 MBZ300 MBZ300 MBZ300 MBZ300 MBZ300 MBZ300 PME PME. Reset. 24V 24V PME PME CM DM SM DM WM Reset Reset Emergency power control unit GB Installation instructions 1 Table of contents 1 Symbols and illustrations...3 2 Product liability...3 3 Safety instructions...3

More information

about your house Assessing the Comfort and Safety of Your Home s Mechanical Systems

about your house Assessing the Comfort and Safety of Your Home s Mechanical Systems about your house CE 28 k Assessing the Comfort and Safety of Your Home s Mechanical Systems The heating, ventilating and air conditioning (HVAC) systems are a vital part of every home. These mechanical

More information

GAS CONTROL SYSTEMS SOLUTIONS OVERVIEW Manifold Systems Control Panels HP/UHP Regulators Pressure Gauges Valves&Fittings

GAS CONTROL SYSTEMS SOLUTIONS OVERVIEW Manifold Systems Control Panels HP/UHP Regulators Pressure Gauges Valves&Fittings www.genstartech.com GAS CONTROL SYSTEMS SOLUTIONS OVERVIEW Manifold Systems Control Panels HP/UHP Regulators Pressure Gauges Valves&Fittings Company Overview Our Team Genstar Technologies is a global leader

More information

PROTECTING AGAINST CARBON MONOXIDE. Questions and Answers about Carbon Monoxide (CO) and CO Alarms

PROTECTING AGAINST CARBON MONOXIDE. Questions and Answers about Carbon Monoxide (CO) and CO Alarms PROTECTING AGAINST CARBON MONOXIDE Questions and Answers about Carbon Monoxide (CO) and CO Alarms WHAT IS CARBON MONOXIDE? Carbon monoxide known by the chemical formula CO is a colorless, odorless, poisonous

More information

Technical Information

Technical Information How to design easily a smoke management system? Mechanical smoke extraction for enclosed car park Car park: specificity of the smoke extraction system Car parks are nowadays integrated directly inside

More information

Fire Extinguishing Concepts for Recycling Plants. 1 Fire Extinguishing Concepts for Recycling Plants

Fire Extinguishing Concepts for Recycling Plants. 1 Fire Extinguishing Concepts for Recycling Plants Fire extinguishing concepts for recycling plants 341 Fire Extinguishing Concepts for Recycling Plants Günter Knopf Ingenieurbüro für Anlagentechnischen Brandschutz Heidesee (Engineering firm for plant-specific

More information

10 Year Smoke Detector and Siren

10 Year Smoke Detector and Siren 10 Year Smoke Detector and Siren SKU: POPE009402 Quickstart This is a secure Alarm Sensor for Europe. To run this device please insert fresh 1 * LS14250 batteries. Please make sure the internal battery

More information

WIRELESS GAS DETECTION & SHUT OFF SYSTEM INSTRUCTION MANUAL. Wireless Gas Detection & Shut Off System - User Manual & Instructions

WIRELESS GAS DETECTION & SHUT OFF SYSTEM INSTRUCTION MANUAL. Wireless Gas Detection & Shut Off System - User Manual & Instructions Wireless Gas Detection & Shut Off System - User Manual & Instructions Please read and follow these instructions prior to installation of the system as correct installation is critical to the performance

More information

CTS Your Partner for Customised Technical Solutions

CTS Your Partner for Customised Technical Solutions How to find us: Karlsruhe Stuttgart A 8 München Exit Empfingen A 81 Haigerloch B 32 B 27 Exit Bodelshausen Rangendingen Tübingen Exit Hechingen Nord Haigerloch Hechingen Singen B 27 Rottweil Balingen Lotzenäcker

More information

Manhattan Fire Protection District

Manhattan Fire Protection District Section: RESCUE OPERATIONS Page 1 of 5 PURPOSE: This procedure is established to ensure proper detection and mitigation of carbon monoxide alarms and emergencies, and to provide a standard of response

More information

T UNI 7000 F. Operating instructions For the user (2006/05) AU/GB

T UNI 7000 F. Operating instructions For the user (2006/05) AU/GB 6 720 648 662-00.1T UNI 7000 F Operating instructions For the user AU/G 2 Contents Contents Contents 2 1 Safety information and explanation of symbols 3 1.1 For your safety 3 1.2 Explanation of symbols

More information

Uniclass L7535 EPIC L13. CI/SfB (57) X. secontrols.com. Smoke Ventilation, Natural Ventilation and Window Automation

Uniclass L7535 EPIC L13. CI/SfB (57) X. secontrols.com. Smoke Ventilation, Natural Ventilation and Window Automation Uniclass L7535 EPIC L13 CI/SfB (57) X Smoke Ventilation, Natural Ventilation and Window Automation We passionately believe that our solutions will improve the indoor built environment We formed SE Controls

More information

Protecting Children from Carbon Monoxide Poisoning

Protecting Children from Carbon Monoxide Poisoning Protecting Children from Please click on any of the links below to go directly to your specified topic within this document. Where Should I Install Carbon Monoxide Detectors? Where Should I install Combination

More information

Side by side. Cascade Venting System for RTG 199HE. Extension Set for units 3 or Installation instructions

Side by side. Cascade Venting System for RTG 199HE. Extension Set for units 3 or Installation instructions Installation instructions Cascade Venting System for RTG 199HE Side by side 6720804520-20.1V Extension Set for units 3 or 4-7 736 501 254 6 720 811 761 / 238-50976-00A (2014/05) Table of contents Table

More information

Smoke Vents. Certified to CE EN Roof Access Systems

Smoke Vents. Certified to CE EN Roof Access Systems Smoke Vents Certified to CE EN12101-2 Roof Access Systems Why natural Smoke and Heat Exhaust Ventilation Systems (SHEVS)? Smoke vents are life-saving appliances. They create a smoke free layer above the

More information

Operating instructions

Operating instructions Operating instructions For the operator Operating instructions ecotec plus Gas-fired wall-hung high-efficiency boiler GB, IE Publisher/manufacturer Vaillant GmbH Berghauser Str. 40 D-42859 Remscheid Telefon

More information

LAMILUX BUILDING CONTROL SYSTEMS ENERGY EFFICIENCY SAFE COMFORTABLE. Customized Intelligence Serving the customer is our first priority

LAMILUX BUILDING CONTROL SYSTEMS ENERGY EFFICIENCY SAFE COMFORTABLE. Customized Intelligence Serving the customer is our first priority LAMILUX BUILDING CONTROL SYSTEMS ENERGY EFFICIENCY SAFE COMFORTABLE Customized Intelligence Serving the customer is our first priority COVER IMAGE: MITTELRHEIN FORUM COBLENZ A new shopping experience is

More information

Back to back. Cascade Venting System for RTG 199HE. Basic Set for units 1 and Installation instructions

Back to back. Cascade Venting System for RTG 199HE. Basic Set for units 1 and Installation instructions Installation instructions Cascade Venting System for RTG 199HE Back to back Basic Set for units 1 and 2-7 736 501 253 6 720 811 762 / 238-50973-00A (2014/05) Table of contents Table of contents 1 Key to

More information

Tailor-made Rubber Extrusion. Cable Manufacturing Lines

Tailor-made Rubber Extrusion. Cable Manufacturing Lines Tailor-made Rubber Extrusion Cable Manufacturing Lines EN Extruders for Cable Sheathing rubicon manufactures particularly adapted extruders and extrusion heads for the production of rubber or silicone-covered

More information

Güntner Info GVX. with microox technology kw. Always a step ahead: microox condenser system with maximum installation flexibility

Güntner Info GVX. with microox technology kw. Always a step ahead: microox condenser system with maximum installation flexibility Güntner Info GVX with microox technology 6 525 kw Always a step ahead: microox condenser system with maximum installation flexibility The new standard for flexibility, technology Energy-saving operation

More information

"Microbox" DC Models MBOX 125/2DC MBOX 125/2DC204

Microbox DC Models MBOX 125/2DC MBOX 125/2DC204 "Microbox" DC Models MBOX 125/2DC MBOX 125/2DC204 Continuous Mechanical Extract Ventilation Unit with Low Energy DC Motor - for domestic and commercial use Installation, Operating and Maintenance Instructions

More information

CO 2. fire extinguishing systems

CO 2. fire extinguishing systems fire extinguishing systems Extinguishing technique is a colourless, odourless and electrical non-conductive gas. In systems the is mixed with a special identifiable odour. The extinguishing effect of is

More information

PRODUCT DESCRIPTION. Renovation smoke exhaust fumivent VdS

PRODUCT DESCRIPTION. Renovation smoke exhaust fumivent VdS PRODUCT DESCRIPTION Renovation smoke exhaust fumivent 4000-11-VdS 04.2016 2 General description The fumivent 4000-11-VdS renovation smoke exhaust can be used to quickly and safely refurbish defective smoke

More information

9 Standards, Regulations and Authorities

9 Standards, Regulations and Authorities 9 9.1 Summary...283 9.2 Basics...284 9.3 Standards and how to Secure Adherence to Standards...285 9.3.1 Types of Standards...285 9.3.2 Hierarchy of Standards...285 9.3.3 Proof...286 9.3.4 Overview of the

More information

designed for rail 5000 Series

designed for rail 5000 Series designed for rail 5000 Series 5000 Series The only complete SIL system 20 years of experience in the field. More than 15.000 systems supplied worldwide. A team devoted to rolling stock projects with specialized

More information

Technologies Gas extinguishing systems. MX 200 Fire Extinguishing Systems Fighting Fire using HFC-227ea

Technologies Gas extinguishing systems. MX 200 Fire Extinguishing Systems Fighting Fire using HFC-227ea Technologies Gas extinguishing systems MX 200 Fire Extinguishing Systems Fighting Fire using HFC-227ea ire protection Efficient and compact MX 200 fire extinguishing systems fight fires using HFC-227ea.

More information

LIGNO LIGNO DEDUST PRO EXPERT SYSTEM SOLUTIONS

LIGNO LIGNO DEDUST PRO EXPERT SYSTEM SOLUTIONS LIGNO LIGNO DEDUST PRO EXPERT SYSTEM SOLUTIONS CONTROL WITH STYLE SIMPLE, STRAIGHTFORWARD, EFFICIENT BASIC In order to provide simple and efficient operation, all dedusters in the DeDust Pro range are

More information

Smoke Vent Control Panel PCB4 V4 Installation Manual

Smoke Vent Control Panel PCB4 V4 Installation Manual Smoke Vent Control Panel PCB4 V4 Installation Manual 10A PCB4 Control Panel Do Not Remove From PCB4 Control Panel www.besafedirect.com Page 1 Contents Page 3) Important Regulations, Safety, Maintenance,

More information

VIESMANN. Service instructions VITOLADENS 300-T. for contractors. Vitoladens 300-T Type VW3B Inox-Radial heat exchanger for oil fired condensing Unit

VIESMANN. Service instructions VITOLADENS 300-T. for contractors. Vitoladens 300-T Type VW3B Inox-Radial heat exchanger for oil fired condensing Unit Service instructions for contractors VIESMANN Vitoladens 300-T Type VW3B Inox-Radial heat exchanger for oil fired condensing Unit VITOLADENS 300-T 1/2007 Please keep safe. Safety instructions Safety instructions

More information

Smoke Vent Control Panel RZN 4202 V1

Smoke Vent Control Panel RZN 4202 V1 Instruction for use Smoke Vent Control Panel RZN 4202 V1 Safety system protects human life and material assets! Once a year functional testing by a specialist company, authorized by the manufacturer. Connection,

More information

Oxeo extinguishing systems

Oxeo extinguishing systems Experts in fire protection Oxeo extinguishing systems TECHNOLOGIES GAS EXTINGUISHING SYSTEMS Residue-free fire extinguishing Oxeo extinguishing systems from Minimax use nitrogen and argon to fight fire.

More information

Property Protect Risk Questionnaire (To be completed for all risks containing high hazard activities / processes)

Property Protect Risk Questionnaire (To be completed for all risks containing high hazard activities / processes) Property Protect Risk Questionnaire (To be completed for all risks containing high hazard activities / processes) Insured Name: Risk Address: New Business Construction: Walls Renewal Policy Number: Building

More information

General Safety Instruction. (for Technical Staff)

General Safety Instruction. (for Technical Staff) General Safety Instruction (for Technical Staff) What is Occupational Health and Safety? Your work and your workplace shall be designed in such a manner as to - avoid work accidents, and - maintain or

More information

Control and Indicating Equipment

Control and Indicating Equipment VdS Guidelines for Fire Detection and Fire Alarm Systems VdS 2540en Requirements and Test Methods VdS 2450en : 2018-12 (03) Publisher and publishing house: VdS Schadenverhütung GmbH Amsterdamer Str. 172-174

More information

Operating Instructions

Operating Instructions Operating Instructions Low Emissions and High Efficiency Condensing Oil Boiler DANGER! If these instructions are not followed exactly, a fire or explosion may be caused with serious property damage or

More information

VIESMANN. Service instructions VITORONDENS 200-T. for contractors. Vitorondens 200-T Type BR2A, 20.2 to 53.7 kw Oil Unit condensing boiler

VIESMANN. Service instructions VITORONDENS 200-T. for contractors. Vitorondens 200-T Type BR2A, 20.2 to 53.7 kw Oil Unit condensing boiler Service instructions for contractors VIESMANN Vitorondens 200-T Type BR2A, 20.2 to 53.7 kw Oil Unit condensing boiler For applicability, see the last page VITORONDENS 200-T 6/2011 Please keep safe. Safety

More information

FIRE DOOR CLOSING SYSTEMS

FIRE DOOR CLOSING SYSTEMS FIRE DOOR CLOSING SYSTEMS AlarmGard & FireGard PREVENT SMOKE AND FIRE DAMAGE According to the National Fire Protection Association (NFPA), in 2014, there were 1,298,000 fires reported in the United States.

More information

DANGER DETECTORS 2016 RANGE

DANGER DETECTORS 2016 RANGE ABUS UK www.abus.com DANGER DETECTORS 2016 RANGE Robust monitoring for underestimated risks: smoke and danger detectors Q4, 2015 CONTENTS EVERYTHING AT A GLANCE DANGER DETECTORS 2016 RANGE In this catalogue,

More information

Homepage > Products > Decentralised ventilation Systems > Vertical devices > Type FSL-V-ZUS. Type FSL-V-ZUS

Homepage > Products > Decentralised ventilation Systems > Vertical devices > Type FSL-V-ZUS. Type FSL-V-ZUS Homepage > Products > Decentralised ventilation Systems > Vertical devices > Type FSL-V-ZUS Type FSL-V-ZUS SECONDARY AIR UNIT FOR SUPPLY AIR, WITH HEAT EXCHANGER, FOR VERTICAL INSTALLATION ON AN EXTERNAL

More information

WATER SPRAY EXTINGUISHING SYSTEMS

WATER SPRAY EXTINGUISHING SYSTEMS WATER SPRAY EXTINGUISHING SYSTEMS FEUERSCHUTZ UND SICHERHEIT THE NATURAL WAY TO PROTECT TECHNOLOGY AND THE ENVIRONMENT Wherever water can be used as an extinguishing agent, it is the preferred choice of

More information

Safe, Effective, Environment-friendly

Safe, Effective, Environment-friendly IG-55 (Argon/Nitrogen) Safe, Effective, Environment-friendly Introduction With the phase out of the most commonly used but environmentally damaging Halon 1301 and CO 2 fire suppressant, inert gases are

More information

DC200 Rack and pinion door closer with link arm

DC200 Rack and pinion door closer with link arm 114 Door closers Rack and pinion door closer with link arm ASSA ABLOY Certified in compliance with EN 114, size 2-4 Suitable for fire and smoke protection doors For single action doors up to 10 mm wide

More information

Carephone 52 Security You Can Feel

Carephone 52 Security You Can Feel Carephone 52 Security You Can Feel 2 The Whole Security Range More so than almost any other company, Bosch stands for technical innovations and revolutionary inventions that have changed the world. With

More information

Rittal Mini Data Centre Modular Safe Extend and Light

Rittal Mini Data Centre Modular Safe Extend and Light Rittal Mini Data Centre Modular Safe Extend and Light Strong arguments for maximum security Benefits you can rely on: Energy-efficient climate control with water- or refrigerant-based cooling tailored

More information

Fire dampers. For diverse applications

Fire dampers. For diverse applications . X X testregistrierung Fire dampers Type with fusible link for 72 C or 95 C CE compliant according to European regulations With TROXNETCOM as an option ATEX certification For diverse applications Rectangular

More information

FIRE DOOR. AlarmGard & FireGard. Preferred door solutions.

FIRE DOOR. AlarmGard & FireGard. Preferred door solutions. FIRE DOOR AlarmGard & FireGard Preferred door solutions. PREVENT SMOKE AND FIRE DAMAGE According to the National Fire Protection Association (NFPA), in 2014, there were 1,298,000 fires reported in the

More information

CARBON MONOXIDE DETECTOR, i4h-co-m330

CARBON MONOXIDE DETECTOR, i4h-co-m330 CARBON MONOXIDE DETECTOR, i4h-co-m330 Alarm LED Power LED Fault LED Air Vents Test/Mute Button Press the latch and push the cover downward to open the battery compartment INTRODUCTION The i4h-co-m330 electrochemical

More information

HIPPS High Integrity Pressure Protection System

HIPPS High Integrity Pressure Protection System HIPPS High Integrity Pressure Protection System L&T Valves L&T Valves Limited (Formerly Audco India Limited) is a wholly owned subsidiary of Larsen & Toubro. Backed by a fifty-year track-record of excellence

More information

Procedure for the Approval of New Fire Detection and Alarm Technologies

Procedure for the Approval of New Fire Detection and Alarm Technologies VdS Guidelines for Automatic Fire Detection and Fire Alarm Systems VdS 3469en Procedure for the Approval of New Fire Detection and Alarm Technologies VdS 3469en : 2016-01 (01) Publisher and publishing

More information

GB162 Concentric Horizontal Vent Kit

GB162 Concentric Horizontal Vent Kit GB162 Concentric Horizontal Vent Kit FOR BUDERUS GB162 SERIES BOILERS Installation Instructions 2 Concentric Horizontal Vent Kit Installation Manual Data subject to change Bosch Thermotechnology Corp.

More information

WINDOW AUTOMATION SOLUTIONS NATURAL AND SMOKE VENTILATION SYSTEMS

WINDOW AUTOMATION SOLUTIONS NATURAL AND SMOKE VENTILATION SYSTEMS WINOW AUTOMATION SOLUTIONS NATURAL AN SMOKE TILATION SYSTEMS SMOKE TILATION MAE SIMPLE 1- PROFILE FICATION Natural smoke heat exhaust ventilators (NSHEs) are installed to provide smoke-free escape routes

More information

Significance of the Construction Products Regulation, including for data centers WHITEPAPER

Significance of the Construction Products Regulation, including for data centers WHITEPAPER Significance of the Construction Products Regulation, WHITEPAPER The aim of the Construction Products Regulation is to protect people in buildings against the consequences of a fire. The priorities in

More information

Fire protection in tunnels and public buildings

Fire protection in tunnels and public buildings Fire protection in tunnels and public buildings One of the most important components of planning and design for tunnels and public buildings by the measures provided for preventive fire protection, especially

More information

Our service. Your protection. Safety: Even when things are on fire.

Our service. Your protection. Safety: Even when things are on fire. Our service. Your protection. Safety: Even when things are on fire. This is what sets our company apart: many years of experience and the certificate of Trust through Security (VdS) as a recognised installer

More information

Operating instructions

Operating instructions Operating instructions (Translation of the original operating instructions) Type TEKA FILTERCUBE-MV TEKA Absaug- und Entsorgungstechnologie GmbH Industriestraße 13 D-46342 Velen Postfach 1137 D-46334 Velen

More information

Titon HRV1 Q Plus HRV1.5 Q Plus HRV2 Q Plus Heat Recovery Ventilation Units

Titon HRV1 Q Plus HRV1.5 Q Plus HRV2 Q Plus Heat Recovery Ventilation Units Titon HRV1 Q Plus HRV1.5 Q Plus HRV2 Q Plus Heat Recovery Ventilation Units Product Manual ventilation systems 2 PCT Patent Application No PCT/GB2009/000114 Contents Introduction...................................

More information

Carbon Monoxide Safety

Carbon Monoxide Safety SFA Guide to Carbon Monoxide Safety Solid Fuel Association 95 High Street Clay Cross Chesterfield Derbyshire S45 9DZ www.solidfuel.co.uk Carbon Monoxide is a highly poisonous gas Carbon Monoxide fumes

More information

Schueco Fire and Smoke Protection Systems

Schueco Fire and Smoke Protection Systems Schueco Fire and Smoke Protection Systems Green Technology for the Blue Planet Clean Energy from Solar and Windows 02 Schueco Fire and Smoke Protection Systems Fire and Smoke Protection Systems Schueco

More information

You are streamlining your manufacturing processes Our automatic machines optimise installation times Let s connect.

You are streamlining your manufacturing processes Our automatic machines optimise installation times Let s connect. You are streamlining your manufacturing processes Our automatic machines optimise installation times Let s connect. Connectivity and electrical installation A high degree of automation for standardised

More information

INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL

INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL CONTENT 3 Introduction 3 General 3 Safety rules 3 Storage and transportation rules 3 Manufacturer s warranty 4 Fan design 4 Delivery set 5 Technical data

More information

To obtain a greater understanding of the factors which contribute towards fire injuries and fatalities

To obtain a greater understanding of the factors which contribute towards fire injuries and fatalities By Richard Walker Project Aims To obtain a greater understanding of the factors which contribute towards fire injuries and fatalities To establish the timeline for Fire Service Intervention for a dwelling

More information

OPERATING MANUAL ORWAK March 2005 PUBL. NO Edition 4

OPERATING MANUAL ORWAK March 2005 PUBL. NO Edition 4 GB OPERATING MANUAL ORWAK 3400 March 2005 PUBL. NO 4869057-00 Edition 4 English TABLE OF CONTENTS Safety... 82 Operating instructions... 93 Technical specifications. 104 Dimensional drawing... 104 Transport...

More information

HERZ ECO-Line Heating with logs or wood pellets

HERZ ECO-Line Heating with logs or wood pellets English HERZ ECO-Line Heating with logs or wood pellets Lambda 18-40 10-60 1 Competence is our success... HERZ FACTS: 50 companies Group headquarter in Austria Research & development in Austria Austrian

More information

U C S AND AUTOMATION SYSTEMS

U C S AND AUTOMATION SYSTEMS U C S WINDOW REMOTE CONTROL AND AUTOMATION SYSTEMS Electric Systems Manual Systems Pneumatic Systems Comfort, Energy Saving and Safety GREEN ARCHITECTURE NATURAL VENTILATION for healthy indoor environment

More information

Tail-end valve stations

Tail-end valve stations VdS Guidelines for water extinguishing systems VdS 2100-15en Requirements and test methods VdS 2100-15en : 2011-05 (02) Publishing house: VdS Schadenverhütung GmbH Amsterdamer Str. 172-174 50735 Köln,

More information

DIESEL/PARAFFIN HEATERS

DIESEL/PARAFFIN HEATERS DIESEL/PARAFFIN HEATERS MODEL NO: XR80, XR110, XR160, XR210 PART NO: 6931004, 6931006, 6931008, 6931012 OPERATION & MAINTENANCE INSTRUCTIONS LS0814 INTRODUCTION Thank you for purchasing this CLARKE product.

More information

VdS 5477en : (01) Key deposit boxes

VdS 5477en : (01) Key deposit boxes VdS 5477en : 2004-03 (01) Key deposit boxes We wish to thank the Police, in particular the Kommission Polizeiliche Kriminalprävention der Länder und des Bundes - KPK (German Police commitee for crime prevention)

More information

MODEL 466 Radiant / Convector Gas Fire Black Beauty

MODEL 466 Radiant / Convector Gas Fire Black Beauty O W N E R G U I D E MODEL 466 Radiant / Convector Gas Fire Black Beauty This Owner Guide is intended to help you care for your Valor gas fire. Please read carefully before using your gas fire and keep

More information

Actionpac LNS3 Intelligent Damper Control and Monitoring System

Actionpac LNS3 Intelligent Damper Control and Monitoring System November 2005 Actionpac LNS 3 NEW AND ENHANCED Intelligent Damper Control and Monitoring System Range and Features Panel PC Driven system. User friendly, no need for operating and maintenance manual. Full

More information

561-MB256 plus. Intruder alarm control panel. Performance features

561-MB256 plus. Intruder alarm control panel. Performance features 561-MB256 plus Intruder alarm control panel The intruder alarm control panel 561-MB256 plus is designed for use in private and commercial zones and is highly suitable for setting up medium to large-sized

More information

OWNER GUIDE. Model 739 OPEN DECORATIVE GAS FIRE. (GC No )

OWNER GUIDE. Model 739 OPEN DECORATIVE GAS FIRE. (GC No ) 5113426/01 OWNER GUIDE Model 739 OPEN DECORATIVE GAS FIRE (GC No. 32-032-54) THIS APPLIANCE IS FOR USE WITH NATURAL GAS (G20). WHEN CONVERTED USING CONVERSION KIT NO. 0595211 THIS APPLIANCE IS FOR USE

More information

HIPPS High Integrity Pressure Protection System

HIPPS High Integrity Pressure Protection System HIPPS High Integrity Pressure Protection System L&T Valves L&T Valves is a wholly owned subsidiary of Larsen & Toubro. Backed by a heritage of excellence that exceeds five decades, the company manufactures

More information

Fire Risk Assessment

Fire Risk Assessment Fire Risk Assessment Maritime Studios Pendennis Rise Falmouth TR11 4FB Carried out by: Date: October 2015 Review Date: October 2016 Les Carter CMIOSH Health & Safety Consultant Mobile 07831 636751, Email

More information

Operating instructions

Operating instructions 6304 0307 04/2005 US For the installer Operating instructions Sealed combustion boiler Logano GA24 SC and atmospheric boiler Logano G24X II/SP If these instructions are not followed exactly, a fire or

More information

Travis County Emergency Services District #1 Standard Operating Guidelines

Travis County Emergency Services District #1 Standard Operating Guidelines PURPOSE CARBON MONOXIDE To establish a procedure for response to carbon monoxide (CO) incidents, to insure the safety of both the firefighters and the public, and to allow for safe incident mitigation.

More information