1 A.U.P.C.I ASOCIACIÓN URUGUAYA DE PROTECCION CONTRA INCENDIO
2 The Essentials of Restaurant Fire Protection Wisconsin Federation of Insurance Co
3 Agenda Restaurant Systems Introduction Testing, Building-Fire Codes & NFPA Standards Non UL Addressed Equipment Pre-Engineered Restaurant Fire Systems Service Requirements Fire Suppression Systems 3
4 Restaurant Systems Introduction 4
5 U.S. Restaurant Fire Statistics 1 Million Restaurants in the United States >$43 Million Property Damage Annually Caused by Commercial Kitchen Fires 1 5
6 Cooking is Leading Cause for Nonresidential Building Fires FIRE FACTS 1 4% increase in cooking fires 23% decrease in intentionally set fires 22% increase in other unintentional fires Cooking Intentional Other Unintentional, Careless Heating Electrical Malfunction 6
7 Restaurant System History: Late 1950 s/early 1960 s Growing concerns escalate as restaurant damage increases from grease fires in hoods, ducts and cooking appliances Insurance industry began increasing premiums and often withheld insurance underwriting altogether Concurrently, Las Vegas, Nevada experienced rapid growth in elaborate and expensive casinos which also had a surge of devastating fires 7
8 Restaurant System History: Early to Mid 1960 s Early years - hood and duct protection only ANSUL R-100 (PS-30) introduced Mid 1960 s - Subject 300 (Pre-ANSI/UL 300) First pre-engineered fire system UL performance fire test protocol for hoods, ducts, and appliances 1964 ANSUL R-101 First UL approved restaurant system 8
9 Restaurant System History: 1970 s 1980 s Late 1970 s Wet Chemical Systems introduced Wet chemical increased cooling, enhanced cleanup 1982 Ansul R Pyro-Chem PCL 9
10 Restaurant System History: 1990 s First dual agent system PIRANHA Wet chemical discharge / water following 15x faster cool down than conventional wet chemical systems Overlapping protection began to be embraced by hood manufacturers and food service consultants Pre-UL 300 Overlapping protection (24 x 36 fryer coverage modularized for all equipment) UL 300 Overlapping protection requires testing UL
11 Restaurant System History: UL 300 / Others s to Present UL 300 standard approved and implemented UL 300 required that all systems to be retested/listed in 1994 making dry chemical systems obsolete Late 1990 s Dry chemical system components no longer supported Existing dry chemical systems lose UL listings Codes & standards reflect UL 300 requirements Local jurisdictions have various levels of upgrade requirements Fire system manufacturers have varied upgrade recommendations NFPA 96 revised to require UL 300 compliance 1997 Subject UL 197 approved for testing re-circulating hoods / appliances UL 710B Replaces UL 197 (Re-circulating Hoods) 2004 Subject UL 199E approved for testing sprinklers & water spray nozzles for fryers 11
12 Testing Building & Fire Codes & NFPA Standards 12
13 Consistent Code Requirements Kitchen Ventilation / Fire Protection NFPA Standards and International Building and Fire Codes Requirements pertaining to testing, construction, use and protection of kitchen ventilation and cooking equipment are consistent within the U.S. National Fire Protection Association (NFPA) NFPA 96 (Ventilation & Fire Equipment) NFPA 17A (Wet Chemical Fire Systems) NFPA 10 (Portable Fire Extinguishers) International Code Council (ICC) IFC (International Fire Code) IBC (International Building Code) Consistent requirements help: Reduce ambiguity Create understanding across regions/jurisdictions Deliver consistent product, service and installation processes Create consumer confidence 13
14 Overview: NFPA 17A (2013 edition) Fire Protection Requirements for Wet Chemical Systems NFPA 17A Standard for Wet Chemical Extinguishing Systems (2013 Edition) covers the following: Components System Requirements Plans & Acceptance Tests Inspection, Maintenance & Recharging NFPA 17A Standard for Wet Chemical Extinguishing Systems 2013 Edition 14
15 Overview: NFPA 96 (2014 edition) Ventilation & Fire Protection Requirements General Requirements Hoods & Grease Removal Devices in Hoods Exhaust Duct Systems & Air Movement Auxiliary Equipment Fire Extinguishing Equipment Use, Inspection Testing & Maintenance Recirculating Systems Solid Fuel Cooking Operations Downdraft Appliance Ventilation Systems NFPA 96 Standard for Ventilation Control and Fire Protection of Commercial Cooking Operations (2014 Edition) 15
16 Overview: NFPA 96 Chapter 10 - Fire Protection Requirements NFPA 96 Standard for Ventilation Control and Fire Protection of Commercial Cooking Operations 2014 Edition 16
17 Codes & Standards Consistency Must be adopted before they are binding NFPA 96 Standard for Ventilation Control and Fire Protection of Commercial Cooking Operations 2014 Edition NFPA 17A Standard for Wet Chemical Extinguishing Systems 2013 Edition NFPA 10 Standard for Portable Fire Extinguishers 2013 Edition Building and Fire Codes, and/or NFPA Standards, must be adopted by State and/or Local Jurisdictions before they are binding Restaurant Fire Suppression Systems are developed to comply with these standards reducing the potential for fire hazards in commercial cooking operations 17
18 Testing / Codes & Standards Third Party Testing In Extreme Conditions 18
19 Testing / Codes & Standards UL 300 Revisions ANSI/UL 300 testing procedures Outlines performance testing of preengineered fire suppression system for UL 300 Listing For each hood, duct & appliance test, restaurant fire suppression system must: Completely extinguish fire Cause no splashing Significant changes to commercial cooking operations contribute to higher retained heat and reduced cooling capabilities 19
20 UL 300 Fire Extinguishing Equipment Testing & Hazard Specific Conventional Type Equipment UL 300 Listings vs Hazard Specific Listings UL 300 Listed Conventional Type Equipment Appliances/Ventilation Appliance Types Fryers and tilt braising pans, griddles, ranges, gas radiant, electric, lava rock, natural, and wood char-broilers, upright broilers, salamander broilers, chain broilers, and woks Ventilation Equipment Hood 4 ft. width x length to be determined by fire system manufacturer Ducts with various perimeters/diameters at various lengths as specified by the fire system manufacturer ( 75 ft. = unlimited length) Hazard Specific / Appliance specific UL 300 Listed Non conventional Equipment can be tested with UL for Hazard Specific UL 300 Listing. Hazard Specific listing includes type, manufacturer s make, and model(s) of the appliance or equipment. 20
21 UL 300 Testing Performance Requirements (Fryer example) 1) Energy Efficient Cooking Equipment (Commercially Available) More Robust Heating - heating rate at least 12 F / min. Insulation cooling rate not to exceed 5 F / min. 2) Vegetable Oil Utilized High Auto-ignition Temperatures Lower Levels of Fatty Acid - Reduced Saponification. 3) Two Minute Pre-Burn Time (Fryer) (2) Minute Pre-Burn - begins after auto-ignition. Fuel Source - to remain ON until agent discharge Longer burn time = higher oil temperatures. 4) Fryers UL No Re-ignition for 20 minutes Or until grease/oil temperature is below 60º F below observed auto-ignition temperature. 5) Splash Testing After successful fire testing, splash testing is required. No splashing grease droplets in excess of 3/16 in. diameter 21
22 UL 300 (Revised Dec. 16, 2014) Cooking Equipment w /Obstructions (Hazard Specific Listings) NEW Pressure Fryer Lid with Basket 22
23 Recently Updated UL 300 Requirement NFPA 96 (2014) 23
24 Upgrade to UL 300 State Mandates More Than 20 Years After UL 300 Adoption Only 6 states mandate all restaurants to be compliant (Blue) 8 states leave legacy compliance to local jurisdictions (Gray) 36 states subject to local AHJ compliance (Green) Currently, all states mandate UL300 compliance to new installations. NFPA 96 (2014) Requires existing as well. Copyright 2014 Tyco Fire Products LP. All rights reserved 24
25 Why Upgrade to UL 300? Protect people, property and revenue streams Insurability at a reasonable cost Protect business from costly litigation Comply with local jurisdictional code
26 Non UL Addressed Equipment 26
27 NFPA 96 (2014) Cooking Equipment Not Addressed in UL 300 Equipment not addressed in ANSI/UL shall be protected in accordance with: Applicable NFPA Standard(s) All local building and fire codes Fire system s manufacturer s recommendations Approved by AHJ 27
28 NFPA 96 (2014) Cooking Equipment Not Addressed in UL 300 Restaurant Fire Risk Reduction 28
29 NFPA 96 (2014) Cooking Equipment Not Addressed in UL 300 Horizontal Chain-Broiler/Pizza oven protection 29
30 NFPA 96 (2014) Cooking Equipment Not Addressed in UL
31 NFPA 96 (2014) Cooking Equipment Not Addressed in UL 300 Partial List Steam Kettles Tandoor Oven Gyro Machine Stock Pots Bar-b-que Pits (5 cu. ft. max.) Wood broiler w/spits Bar-b-que Pits (over 5 cu. ft.) Toasters Clam Shell Grill Pig Smoker Hibachi Downdraft Mongolian Griddle Rotisseries (carousel and not carousel) Chain Pizza Ovens Rotisserie/Broiler Combo (Gas Fired, Wood Fired or Both) Rice Cookers Standard Pressure Fryers Pressure Fryers (with basket obstructions) Candy Cookers Brazilian Gas/Wood Grills Baine Marie Standard Ovens Combination Griddle Top/Drawer (pull out) Griddle-Broiler Chain Broilers w/catalytic Convertors Chinese Smoker Standard Range/Wok Range Combo Cheese Melter Meat Glazing Operations Conveyor Fryers (over 6 sq. ft. max.) Baffle Non-water-wash Hoods Water-wash Hoods Pollution Control Units (PCUs) UVC Filtering Units Open Hearth Pizza Ovens (Wood, Gas, or both) (With/without doors) In Duct Filters or Dampers 31
32 NFPA 96 (2014) Cooking Equipment Not Addressed in UL 300 Cooking Equipment NOT Specifically Addressed in UL 300 1) UL 300 includes Specific performance test requirements for listing conventional appliance & ventilation type equipment, (most often used in Commercial Cooking). Cooking or ventilation processes that do not have performance test requirements addressed in UL 300 need to be reviewed to determine level of fire risk, and whether fire protection is needed. NFPA 96, Equipment that: 1. Produce grease-laden vapors, and Might be a source of ignition in the hood, grease removal device, or duct 32
33 UL 300 Fire Extinguishing Equipment Hazard Specific Listings Fire system manufacturers work directly with UL to obtain hazard specific listings for Equipment NOT included in UL 300 UL 300 Approved Hose UL 300 Ranges/Shelves UL 300 Equipment with Obstruction 33
34 UL ANSUL Fire Extinguishing Equipment Hazard Specific Listings FRYERS Dean Industries Gas Fryer, Model 2424 GTI, 120,000 BTU/hr. Rating Far West Hospitality Products Gas Fryer, Model PAR-1-20, BTU/hr. Rating Frymaster 14 KW 208V Electric Fryer, Model MACH 14 Frymaster Energy Efficient RE 14 Fryer McDonald Fryer (Nozzle Heights of Less Than 20 inches) Henny Penny Mono Rail Center Lift System Models 690, 691, 692 Henny Penny Dual Lift System Models 580, 581, 582, 590, 591, 592, 682, 691 Henny Penny Dual Lift System Model PXE-100 Pitco SPINFRESH Fryer Models MEII, MGII, SE14, SE14R,SE14X,SG144S,SG14RS Belshaw Century Fryers Models C100, C200, C200G, C300G, C400G, C600G Dunkin Donuts Fryer Model DD400CGF Krispy Kreme Fryers Models 55M, 65 D/H, 110 D/H, 110M, 150 D/H, 220M, 600 D/H, and 1000 D/H BROILERS Garland Electric Dual-Side Clamshell Broiler Model CXBE12 Duke Chain Broiler Model FBB Nieco Broiler Model 940, 950, 960, 962, 960, 980, 9015, 9025, 1424, MPB94 and MPB84 Nieco Broiler Model JF94E, JF62, JF63, JF92, JF93, JF143, JF64G, JF84G, JF94G Bakers Pride Broiler Model CH6, CH8, CH10, XX6, XX8, XX10 (With wood smoker box) MagiKitch n Gas Radiant Broiler Model FM-RMB-660, FM-RMB-648, FM-RMB-636 (With wood smoker box) Marshall Air Chamber Broiler Model 2001BK Marshall Air Electric Broiler Model FR14B Auto-Broil 34
35 NFPA 96 (2014) Other Equipment Not Addressed in ANSI/UL PCUs Protection has been recommended by manufacturers with conventional wet chemical systems NFPA 96 Standard for Ventilation Control and Fire Protection of Commercial Cooking Operations 2014 Edition 35
36 Pre-Engineered Restaurant Fire Suppression Systems 36
37 Global Markets /Global Approvals Needed Global Markets 37
38 Testing / Codes & Standards Standard UL300 Standards for Safety Canada ULC Standard ORD C United States NFPA Standard 96 UL Standard 300 UL Standard 1254 IAPMP Standard PS NFPA Standard 17A EMEA LPS 1223 Pressure Equipment Directive (97/23/ECP) Ukraine State Certifications Centre MOE VdS Approval ANPI OKF Orszagos Katasztrofavedeimi Foigazgatosag (National Directorate General for Disaster) INDIA NBC Russia Fire Academy of Russia China GA S. Korea KFI Japan Kentei Singapore PSB ISO-15371:2009 Lloyd s Register MED Approval UL and USCG Approval Type Approvals for ABS and DNV 38
39 TFPP Restaurant Systems ANSUL ANSUL PYRO-CHEM Protecting 95% of Industry s Top 100 Restaurant Chains Fine and Casual Dining Stadiums, Casino/Hotels Industry s Most Robust Suppression System High Hazard/Risk Applications Exclusive with Hilton and Marriot Hotels Number 2 in the Industry Popular with Independent Restaurants Chain Restaurant Presence Hospitals Stadiums Lodging 39
40 TFPP Restaurant Systems Stored Pressure and Cartridge Operated Systems 40
41 TFPP Restaurant Systems Cartridge Operated Systems Tank(s) - Agent filled and non-pressurized until system actuation & discharge Cartridge(s) - Sealed CO 2 or N 2 providing expellant gas pressure at time of actuation Hermetically sealed and leak tested simulating 127 years within tolerance. 800 or 1800 psi Releasing Device Supports cartridge Mechanically or electrically activated Allows consistent ®ulated tank / nozzle pressure Provides shutdown and remote alarm interface 41
42 TFPP Restaurant Systems Stored Pressure Systems Tank(s) - Agent filled and pressurized Generally N 2 ~ º F Discharge outlet is contained within tank valve Releasing Device Attached to tank valve Or remote N 2 cylinder for multiple tank operation Mechanically or electrically activated Provides shutdown and remote alarm interface 42
43 TFPP Restaurant Systems R-102 Pre-Engineered Fire Suppression Systems Cartridge Operated 43
44 TFPP Restaurant Systems R-102 Fire Suppression Systems Offers Appliance Specific or Overlapping Protection 44
45 TFPP Restaurant Systems PIRANHA Fire Suppression Systems Cartridge Operated Hybrid System Overlapping Protection High Height Nozzle Location Hybrid (Dual Agent) concept Provides Superior Cooling 15 x Faster Cool Down than Conventional Wet Chemical Systems 45
46 The PIRANHA Advantage The primary advantage of the hybrid system over single-agent wet chemical systems is a significantly higher safety margin in the suppression of grease fires. It cools cooking oils up to 15 times faster Testing revealed the hybrid approach required 60% less chemical agent less than singeagent wet chemical systems Awareness needs to be increased around PIRANHA facts such as the system can be connected to sprinkler or potable water sources vs. sprinkler systems 46
47 Restaurant Fire Suppression Systems R-102 & PIRANHA Agents Ansulex Low ph Dense stable foam blanket Not compatible with water (water destroys foam blanket) Insulates hot oil resulting in slower cool-down rate. PRX Less dense foam blanket Compatible with water, tempering shortening to mitigate volumetric expansion of water. Large unstable bubbles release heat in form of steam, but are continually re-vitalized with water spray. 47
48 TFPP Restaurant Systems PIRANHA - Wet Chemical Initial PRX wet chemical discharge 1) Quick fire knockdown 2) Saponification Creates large bubbles that are continuously renewed by water discharge 3) Agent tempers violent reaction between water and super-heated oil Subsequent water discharge 1) Water continues Until water is shut off, or Optional 10 min. auto-water shutdown 2) Constantly renews foam blanket 4) Superior cooling Generally 15 x faster than conventional single agent wet chemical systems 48
49 TFPP Restaurant Systems Kitchen Knight II Pre-Engineered Fire Suppression Systems Stored Pressure 49
50 Sequence Of Operation 1) A faulty limit switch in a fryer cause an overheat condition, auto-igniting the cooking oil. 50
51 Sequence Of Operation 2) Heat, generated from the fire transfers to a fusible link, causing it to separate, resulting in slack in the detection cable. 51
52 Sequence Of Operation 3) If the system utilizes cartridge operation, the resulting slack will trip a release mechanism, puncturing a seal in a cartridge. 52
53 Sequence Of Operation 3) If the system utilizes a stored pressure tank, the resulting slack will trip a release mechanism, opening up the tank valve. 53
54 Sequence Of Operation 4) N2 Or CO2 Gas Pressure In The Tank, Allows Agent To Discharge Through Piping & Nozzles Into Pre-Determined Hazard Areas. 54
55 Restaurant Projects 55
56 Ceiling Ventilation Project
57 Ceiling Ventilation Project Background Ceiling ventilation is used for high end installations in the various markets and is in need of a more aesthetically pleasing fire suppression solution Primarily found in Europe however rapidly expanding into other regions of the world Vaulted Dome Double Extraction Plenum Single Extraction Plenum Aerosol Separator / Blind panels Lighting Built in Supply Air Diffusors Supply Air Duct System Exhaust Air Duct System 57
58 Ceiling Ventilation Project (High Nozzle Height) Project objective: Nozzle placement at higher vertical heights (90 to 120 above the finished floor) Features: PIRANHA - System Only P41 Nozzle (Pt. No ) 54 in. to 60 in. above appliance surface P34 Nozzle (Pt. No ) 60 in. to 84 in. above appliance surface Overlapping Scheme 25.5 in. spacing Center to Center Nozzle location must be located forward of the center-line and within the outlined section per manual UL Certified Exceptions: No back shelves allowed with new scheme No Class A Broilers (Mesquite, Lava, and Charcoal) Protects Woks up to 18 in. 58
59 Taking Restaurant Fire Suppression to New Heights Nozzles remain out of view while providing the same reliable protection UL Certified Aesthetic design complements décor Eliminates visible nozzle drop piping Reduces potential for nozzle redirection or obstruction Simplifies hood cleaning and service Easy to upgrade existing systems In some applications the nozzles may be installed above the cooking appliance line directly in the hood seals penetrating the top of the hood 59
60 Product Detail P34 Nozzle PN Pack Nozzle vertical heights: above the appliance surface P41 Nozzle PN Pack Nozzle vertical heights: above the appliance surface 60
61 Design Detail Overlapping Appliance Nozzle and Hazard Zone Locations High Proximity The nozzles located within the outlined section forward of the centerline or aim-line of the selected hazard zone. Note: The centerline of the hazard zone or aim-line cannot exceed 16 in. (406 mm) from either the front or back edge of the zone. Exception: Fryer, griddle, braising pan/tilt skillet. The hazard zone must be located from front to rear so that its 32 in. (813 mm) depth covers the depth of all the cooking hazards of the protected appliances. Exception: If depth of the cooking hazard of a fryer, griddle or braising pan/tilt skillet exceeds 32 in. (813 mm), position the hazard appliance so that its rear edge is located a maximum of 4 in. (101 mm) beyond the rear of the hazard zone. Nozzle spacing remains the same as the AP Nozzles 61
62 Design Detail 62
63 PIRANHA High Nozzle Height Option Before After 63
64 Service Requirements Fire Suppression System Recharging Monthly Inspections Semi-Annual/ Annual Maintenance 12-Year Inspection & Maintenance 64
65 Inspection, Testing, and Maintenance NFPA 17A, Chapter 7 Maintaining fire system integrity and hand portable effectiveness Fire suppression system(s) and hand portable(s) MUST be: installed and serviced regularly By properly trained and authorized service companies. 65
66 Inspection, Testing, and Maintenance NFPA 17A, Chapter 7 NFPA 17A, Chapter 7 Inspection, Maintenance and Service At lease semiannually,.. maintenance shall be conducted in accordance with the manufacturer s listed installation and maintenance manual. A Regular service contracts with the equipment Manufacturer or an authorized installation or maintenance Company is recommended Monthly - Owner responsibility Semi-annually Distributor maintenance Annually Additional checks (12) year - Hydrostatic test requirements/other ANSUL- Owner Operator Video is available Owner s daily responsibility Description of semi-annual and annual Distributor Maintenance 66
67 Inspection, Testing, and Maintenance NFPA 17A, Chapter 7 / NFPA 96, Chapter 11 Service by Trained and Certified Distributor 67
68 Inspection, Testing, and Maintenance NFPA 17A Semi-Annual Maintenance Trained / Authorized Distributors Maintenance, Recharge Hold current certification (1-2 day class, 3 yr. certification duration) Licensed by State and/or local jurisdiction(s) Direct access to manufacturer s technical updates, bulletins, original parts, etc. Design & maintenance manual / updates Technical service support William Klingenmaier, employee of Tyco Fire Protection Products Completed a training course in: ANSUL R-102 Restaurant Systems Training Date: April 8, 2015 Expiration Date: April 8, 2016 TYCO FIRE PROTECTION PRODUCTS, MARINETTE, WI
69 Inspection, Testing, and Maintenance NFPA 17A / NFPA 96 Maintenance Service Requirements Semi-Annually In accordance with Manufacturer s Installation and Maintenance manual and bulletins NFPA 17A NFPA 96 69
70 Inspection, Testing, and Maintenance PCU Semi-Annual Maintenance PCU protection/system also needs to be inspected and maintained. Filter media Grease buildup Nozzles Detection Fuselink replacement 70
71 Inspection, Testing, and Maintenance NFPA 17A 12 Year Service 7.5 Hydrostatic Testing Wet chemical containers Mfg. date on tank collar, bottom, label, etc. Auxiliary pressure containers Exception (1) 2 in. diameter and < 2 ft. length Exception (2) DOT 3E Hose assemblies, or hose replacement Wet chemical agent replaced 71
72 Inspection, Testing, and Maintenance NFPA 17A 12 Year Service 12 Year Service Manufacturers may require additional service procedures Service performed by certified and trained distributor ANSUL - Mild steel tanks replaced with stainless steel tank ANSUL Cartridges de-pressurized and replaced ANSUL Regulator test Perform remainder of semi-annual examination 72
73 Inspection, Testing, and Maintenance NFPA 17A After Service Examination Review system status with manager or owner / operator after service 73
74 Inspection, Testing, and Maintenance Typical Inspection Issues / Mistakes Fire Suppression Systems DO Require Code Inspection This won t work! (dry chemical release w/wet chemical tank and NO regulator) Good reason for restaurant owners to use trained and authorized service companies Bad electrical 74
75 Inspection, Testing, and Maintenance Typical Inspection Issues / Mistakes Fire Suppression Systems DO Require Code Inspection Broken detection line Extension cord 75
76 The Essentials of Restaurant Fire Protection Questions? 76
77 77
R-102 RESTAURANT FIRE SUPPRESSION SYSTEM
R-102 RESTAURANT FIRE SUPPRESSION SYSTEM DESIGN, INSTALLATION, Recharge, and Maintenance Manual One Stanton Street / Marinette, WI 54143-2542, USA / +1-715-735-7411 / www.ansul.com Copyright 2014 Tyco
More informationKitchen Fire Suppression Systems Post-Event Analysis
Kitchen Fire Suppression Systems Post-Event Analysis Adam Farnham, PE, CSP, IAAI-CFI Fire Protection/Mechanical Engineer Snohomish, Washington October 22, 2014 Presentation Outline 1. Overview of System
More informationANSUL TO-ANSUL. For more information... Check your local Yellow Pages for your authorized Ansul Restaurant Systems Distributor.
For more information... Check your local Yellow Pages for your authorized Ansul Restaurant Systems Distributor. Or call Ansul direct at... 1-800-TO-ANSUL (Toll-Free USA/CAN) or 1-715-735-7411 USA FAX:
More informationMobile Vendors Bulletin
Mobile Vendors Bulletin NUMBER: 13-01 Amended Jan 18, 2016 PURPOSE City of Penticton Regulations for Mobile Vendors This guideline is intended to provide an overview of the City of Penticton requirements
More informationCommercial Kitchen Exhaust Requirements Kitchen Exhaust for Food Service Operations
Commercial Kitchen Exhaust Requirements Kitchen Exhaust for Food Service Operations District of Lake Country 10150 Bottom Wood Lake Road Lake Country, BC V4V 2M1 t: 250-766-6675 f: 250-766-0200 Inspection
More informationNFPA 96, 2017 REVIEW SUMMARY
NFPA 96, 2017 REVIEW SUMMARY 1) NFPA 96 REVISION SUMMARY NFPA 96 Standard for Ventilation Control and Fire Protection of Commercial Cooking Operations The 2017 edition adds a new normative annex on mobile
More informationMECHANICAL EXHAUST VENTILATION SYSTEMS OPERATIONAL GUIDELINES-REVISED 2003
MECHANICAL EXHAUST VENTILATION SYSTEMS OPERATIONAL GUIDELINES-REVISED 2003 California Conference of Directors of Environmental Health I. Background Proper venting and capture of the gases, heat, grease,
More informationShips and marine technology Fireextinguishing. of galley cooking equipment
INTERNATIONAL STANDARD ISO 15371 Third edition 2015-11-15 Ships and marine technology Fireextinguishing systems for protection of galley cooking equipment Navires et technologie maritime Systèmes d extinction
More informationTypes of Detection. Fusible Link Detection - Most Common
Types of Detection Fusible Link Detection - Most Common Types of Detection Electric Detection Types of Detection Pneumatic Detection-Tubing Pneumatic Tubing 3 Year Service life Survey Hazard 1) List all
More informationSwiftclean and ANSUL. AXA s Commercial Kitchen Fire Safety Service. Ansul is a leading brand of Johnson Controls International PLC
Swiftclean and ANSUL AXA s Commercial Kitchen Fire Safety Service Ansul is a leading brand of Johnson Controls International PLC Fire risk Of all occupancy types, food and drink premises are the third
More informationChapter One Commercial Kitchen Fires
Table of Contents Table of Contents Chapter One Commercial Kitchen Fires COMMERCIAL KITCHEN FIRES... 2 The Commercial Kitchen Fire Problem... 2 Unreported Fires... 2 Cooking By-Products... 3 Grease Accumulation
More informationCOMMERCIAL KITCHEN SUPPRESSION SYSTEMS INFORMATION PACKET
COMMERCIAL KITCHEN SUPPRESSION SYSTEMS INFORMATION PACKET Colorado Springs Fire Department Division of the Fire Marshal October 2013 Table of Contents PURPOSE... 3 SCOPE... 3 DEFINITIONS... 3 GUIDELINES...
More informationISO INTERNATIONAL STANDARD. Ships and marine technology Fire-extinguishing systems for protection of galley cooking equipment
INTERNATIONAL STANDARD ISO 15371 Second edition 2009-03-15 Ships and marine technology Fire-extinguishing systems for protection of galley cooking equipment Navires et technologie maritime Systèmes d'extinction
More informationEVALUATION SUBJECT: GILES RECIRCULATING (VENTLESS) HOODS
ICC-ES Report PMG-1004 Reissued 08/2017 This report is subject to renewal 08/2018 EVALUATION SUBJECT: GILES RECIRCULATING (VENTLESS) HOODS DIVISION: 23 00 00 HEATING, VENTILATING AND AIR CONDITIONING (HVAC)
More informationLABEL PLEASE NOTE: ALL APPLICATIONS AND SITE PLANS MUST BE COMPLETED IN BLACK OR BLUE INK ONLY
STAFF USE ONLY Thurston County Resource Stewardship 2000 Lakeridge Dr. S.W. Olympia, WA 98502 (360)786-5490 / (360)754-2939 (Fax) TDD Line (360) 754-2933 Email: permit@co.thurston.wa.us www.co.thurston.wa.us/permitting
More information2012 ICC Commercial Kitchen Hoods
Welcome 2012 ICC Commercial Cooking Hoods Based on the: 2012 International Mechanical Code (IMC ) 2012 International Fire Code (IFC ) 2012 International Fuel Gas Code, (IFGC ) 2012 International Building
More informationMSYS 4490 AC Systems
MSYS 4490 AC Systems Winter 2015 KITCHEN VENTILATION SYSTEMS By Satwinder Singh 12/02/2015 1 12/02/2015 2 By Satwinder Singh 1 12/02/2015 3 12/02/2015 4 By Satwinder Singh 2 Type I: Types of Hoods used
More informationFIRE PROTECTION SYSTEM FOR INDUSTRIAL KITCHENS
BLACK by by SEVO Systems SEVO Systems Black Diamond Fire Protection System for Industrial Kitchens is safe for humans and environmentally friendly. It utilizes the most advanced technology available, differentiating
More informationCALIFORNIA DEPARTMENT of FORESTRY and FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL UL 300
CALIFORNIA DEPARTMENT of FORESTRY and FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL UL 300 FREQUENTLY ASKED QUESTIONS CONCERNING COMMERCIAL COOKING PROTECTION Published by FIRE ENGINEERING DIVISION
More informationPORTABLE PERFORMANCE ANSUL Stored Pressure Fire Extinguishers
PORTABLE PERFORMANCE ANSUL Stored Pressure Fire Extinguishers READY FOR ACTION WHEN YOU ARE. Every year, cooking accidents, unattended candles, electrical failures, careless smoking and other incidents
More informationFire Suppression Installation (R-102) for AVI Hoods & XLT Ovens
XD 9011E ABGKSWBGHAE 10/16/2017 Fire Suppression Installation (R-102) for AVI Hoods & XLT Ovens CAUTION This appliance is for professional use by qualified personnel. This appliance must be installed by
More informationProject Name: Project Address: Installer Name: Installer Address: Date of Inspection:
FIRE DEPARTMENT Kitchen Range Hood Fire Suppression System Acceptance Test Project Name: Project Address: Installer Name: Installer Address: Date of Inspection: DOCUMENTATION NO Plans have been reviewed
More informationCORPUS CHRISTI FIRE PREVENTION MOBILE FOOD VENDOR REQUIREMENTS
CORPUS CHRISTI FIRE PREVENTION MOBILE FOOD VENDOR REQUIREMENTS FIRE EXTINGUISHER REQUIREMENTS 1. All commercial cooking operations require at least one 2A10BC rated (5 or 6 pound size) fire extinguisher.
More information60 Years of Commercial Kitchen Fire Suppression
60 Years of Commercial Kitchen Fire Suppression BY BILL GRIFFIN, ASSOCIATE MEMBER ASHRAE; AND MIKE MORGAN, ASSOCIATE MEMBER ASHRAE Fire suppression systems for commercial kitchens have progressed significantly
More informationA Guide for Meeting NFPA 10 Subsection
TECHNICAL BULLETIN A Guide for Meeting NFPA 10 Subsection 5.5.1.1 Extinguishers for Pressurized Flammable Liquids and Pressurized Gas Fires One Stanton Street / Marinette, WI 54143-2542, USA / +1-715-735-7411
More informationSecond Revision No. 1-NFPA 17A-2016 [ Section No ] Submitter Information Verification. Committee Statement. 1 of 14 6/22/2016 3:15 PM
1 of 14 6/22/2016 3:15 PM Second Revision No. 1-NFPA 17A-2016 [ Section No. 4.3.3 ] 4.3.3 All discharge nozzles shall be provided with caps or other suitable devices to prevent the entrance of grease vapors,
More informationREADY FOR CHANGE. A Guide for Meeting the NFPA Compliance Standard for Portable Fire Extinguishers
READY FOR CHANGE A Guide for Meeting the NFPA 10-2010 Compliance Standard for Portable Fire Extinguishers THE CHALLENGES A QUICK REVIEW The NFPA 10 Standard contains many guidelines that may impact you
More informationSERVICE VERSUS REMOVAL OF OBSOLETE COMMERCIAL KITCHEN PRE-ENGINEERED FIRE SUPPRESSION SYSTEMS
SERVICE VERSUS REMOVAL OF OBSOLETE COMMERCIAL KITCHEN PRE-ENGINEERED FIRE SUPPRESSION SYSTEMS The members of the Fire Equipment Manufacturers Association (FEMA) are in the business of providing the very
More informationCOMMERCIAL KITCHEN FIRE SAFETY
COMMERCIAL KITCHEN FIRE SAFETY COMMERCIAL KITCHEN FIRE SAFETY Commercial grade kitchens are a common feature found in senior living communities. Operation of a commercial grade kitchen, many safety considerations
More informationKITCHENShield WCK Kitchen Fire Suppression System. Advanced fire protection systems
WCK Kitchen Fire Suppression System With over 60 years' experience, Lehavot has long been recognized pioneer and leading provider of high quality Fire Protection systems. Incorporating the most advanced
More informationWater Mist Fire Protection Systems for the Protection of Industrial Oil Cookers. 8th March 2016 Dr Tim Nichols CPhys MIFireE
Water Mist Fire Protection Systems for the Protection of Industrial Oil Cookers 8th March 2016 Dr Tim Nichols CPhys MIFireE Industrial Oil Cookers 2 What are Industrial Oil Cookers Large cooker of food
More informationVENTLESS EXHAUST HOOD OPERATORS MANUAL AND PARTS LIST REV. MAY 2016
VENTLESS EXHAUST HOOD OPERATORS MANUAL AND PARTS LIST REV. MAY 2016 HOODMART 172 REASER COURT ELYRIA, OH 44035 PHONE: (800)-715-1014 FAX: (800)-716-1214 1 THIS PAGE LEFT BLANK INTERNTIONALLY 2 LIMITED
More informationCORE Protection Fire System Specification
CORE Protection Fire System Specification The CORE restaurant fire suppression system is a pre-engineered, duct and plenum water spray system in conjunction with a wet chemical, cartridge-operated, regulated
More information2015 ICC Commercial Cooking Systems
2015 ICC Commercial Cooking Systems Based on the: 2015 International Building Code (IBC ) 2015 International Mechanical Code (IMC ) 2015 International Fire Code (IFC ) 2015 International Fuel Gas Code
More informationVentless Operation Supplement GBF-D-VH
Operations & Service Manual GBF-5D-VH GBF-50D-VH Ventless Operation Supplement GBF-D-VH Giles Enterprises, Inc. An ISO900 Registered Company Committed to Quality 750 Gunter Park Drive West Montgomery,
More informationI wish I could protect my business with the most suitable Water Mist solution to fit my needs.
I wish I could protect my business with the most suitable Water Mist solution to fit my needs. Wish granted! Tyco AquaMist systems are a versatile and highly efficient fire-fighting resource, featuring
More informationFirst Revision No. 49-NFPA 17A-2015 [ Detail ] Submitter Information Verification. Committee Statement 7/30/2015 1:35 PM
of 25 7/30/2015 1:35 PM First Revision No. 49-NFPA 17A-2015 [ Detail ] Make the following change to 5.2.1.10.2: 5.2.1.10.2* The manual actuation device shall clearly identify the hazard protected and provide
More informationFire Suppression Investor Overview
Fire Suppression Investor Overview George Oliver President, Safety Products and Electrical & Metal Products David LeBlanc Director, New Product Introduction June 23, 2009 Agenda Overview of Fire Suppression
More informationSPECIFICATION: DRY CHEMICAL FIRE SUPPRESSION SYSTEM FOR INDUSTRIAL APPLICATIONS MODEL IND
1. GENERAL SPECIFICATION 1.1 A pre-engineered, fixed pipe, automatic dry chemical fire suppression system shall be provided and installed for the hazard including work area, plenums and all exhaust ventilation
More informationDear Concessionaire,
Dear Concessionaire, In order to provide a comprehensive review & inspection of the Vendor application please review the following as guidance to a complete application and preparedness for inspection.
More informationKITCHEN HOOD AND DUCT FIRE SUPPRESSION SYSTEM
PART 1 GENERAL 1.01 SUMMARY SECTION 15371 KITCHEN HOOD AND DUCT FIRE SUPPRESSION SYSTEM A. Section Includes: A complete automatic fire suppression system for the exhaust hood, including necessary accessories.
More informationMinimum Information Required to Process your Special Occasion Application. Parking area Access to site
FIRE CODE PERMIT SPECIAL OCCASION APPLICATION YAKIMA COUNTY FIRE MARSHAL S OFFICE International Fire Code 128 N. 2nd Street, 4th floor, Yakima, WA 98901 - (509) 574-2300 FORM: BFS45A 6/5/18 Minimum Information
More informationTHE IDEAL SOLUTION FOR KITCHENS
THE IDEAL SOLUTION FOR KITCHENS Restaurants, hotels and all types of buildings housing commercial kitchens increasingly require specific fire protection that deliver maximum protection against fire. The
More informationSECTION KITCHEN HOOD AND DUCT FIRE SUPPRESSION SYSTEM
PART 1 GENERAL 1.01 SUMMARY SECTION 15371 KITCHEN HOOD AND DUCT FIRE SUPPRESSION SYSTEM A. Section Includes: A complete wet chemical automatic fire suppression system for the exhaust hood, including necessary
More informationWater Mist Fire Suppression
Water Mist Fire Suppression How less water has a big impact. HELPING PROTECT YOUR BUSINESS AND VALUED ASSETS WITH WATER MIST FIRE PROTECTION SYSTEM INTRODUCTION Many buildings have specific areas that
More information2-SUPPRESSION REQUIREMENTS - CODE REQUIRED INSPECTIONS TEST Page 1 of 7
WET SPRINKLER Monthly Wet Sprinkler 2-SUPPRESSION REQUIREMENTS - CODE REQUIRED INSPECTIONS TEST Page 1 of 7 VISUALS [per NFPA 25-1998 ed] 1. Gauge (Ck for Condition, Normal Pressure) [per 2-2.4.1] 2. Valves
More informationIntroduction to the Exhaust Fan Interceptor Commercial Exhaust Fans from a Service Perspective
2012 Introduction to the Exhaust Fan Interceptor Commercial Exhaust Fans from a Service Perspective 2012 - Superior Restaurant Services 3/21/2012 2012 - Superior Restaurant Services 2 Contents Introduction...
More informationSANDUSKY FIRE DEPARTMENT Fire Prevention Bureau. Dear Prospective Food Vendor:
SANDUSKY FIRE DEPARTMENT Fire Prevention Bureau 600 West Market Street Sandusky, OH 44870 Phone: 419.627.5823 FAX: 419.627.5820 www.ci.sandusky.oh.us Dear Prospective Food Vendor: The purpose of this information
More informationDEPARTMENT OF LICENSING AND REGULATORY AFFAIRS DIRECTOR S OFFICE GENERAL INDUSTRY SAFETY STANDARDS PART 8. PORTABLE FIRE EXTINGUISHERS
DEPARTMENT OF LICENSING AND REGULATORY AFFAIRS DIRECTOR S OFFICE GENERAL INDUSTRY SAFETY STANDARDS (By authority conferred on the director of the department of licensing and regulatory affairs by sections
More informationXRRS Specification Fire Ready Hood
XRRS Specification Fire Ready Hood ************************************************************************************************************************ Note to User: This document is subject to copyright
More informationTwin-Agent Fire Fighting/Securing Systems Specifications
Twin-Agent Fire Fighting/Securing Systems Specifications Models 450/50, 450/100, 900/100 & 1350/200 INDEX 1.0 GENERAL 1.1 References 1.2 Submittals 1.3 System Capabilities 1.4 Quality Control 1.5 Warranty,
More informationSafer.Smarter.Tyco. Watermist fire protection Technology you can trust
Safer.Smarter.Tyco. Watermist fire protection Technology you can trust / 2 / / 3 / Trust in Tyco Tyco s AquaMist Systems Tyco Fire Protection Products helps to keep people, property and the environment
More informationLow Wall Back Shelf Exhaust Canopy
ITEM NO. 710 Powerline Road Suite H Deerfield Beach, FL 33442 (954) 570-9860 (800) 322-8730 FAX (954) 570-9865 Low Wall Back Shelf Exhaust Canopy Model LW APPLICATION Wall mounted canopy style ventilator
More informationMOBILE FOOD VENDING Food Trucks & Trailers
MCKINNEY FIRE DEPARTMENT FIRE MARSHAL S OFFICE MOBILE FOOD VENDING Food Trucks & Trailers These guidelines are to be followed when a business, facility or organization plans to operate a food truck or
More information*** Inspection *** Please identify yourself as a Cintas representative when arriving onsite.
Tech Clock-In/Out IVR: 1-877-349-2906 Job #: Tech ID #: 2902 FP Service Instructions Job #: *** Inspection *** You must clock in and out of this job through Cintas's IVR phone system! Call 1-877-349-2906
More informationenews 2012 Annual Conference
I N S U R A N C E LO S S CO N T R O L ASSOCIATION Founded by and dedicated to the professional insurance company loss control representative A P R I L 2 0 1 2 enews www.insurancelosscontrol.org I N S I
More informationOsceola County Department of Fire Rescue and Emergency Medical Services
St. Number Dir Street Name Street Type Inspected Time of Day to be Re-inspected Zip Code Occupancy Type Emergency Contact Phone (Inc. Area Code) Building Owner Building Owner Mailing Address Bldg. Owner
More informationSafety Tips for the Office
Safety Tips for the Office An office fire can be devastating - resulting in business interruption or permanent closure, loss of lives, jobs, property and information. Offices are loaded with combustible
More informationUNIFIED FACILITIES GUIDE SPECIFICATIONS
USACE / NAVFAC / AFCEC / NASA UFGS-21 21 03.00 10 February 2009) ---------------------------------- Preparing Activity: USACE Superseding UFGS-21 21 03.00 10 (April 2006) UNIFIED FACILITIES GUIDE SPECIFICATIONS
More informationSTORED PRESSURE YES TEST STANDARDS: CAN/ULC S504 & ANSI/UL 229 CAN/ULC S508 & ANSI/UL 711. Available Options: Stationary Design Tow Loop
STORED PRESSURE 50, 125/150 lb. Stored Pressure These commercial stored pressure extinguishers are available in a choice of two sizes and three chemical options. The carriage design on both sizes provides
More informationKitchen Suppression System Manuals
Kitchen Suppression System Manuals If looking for a ebook Kitchen suppression system manuals in pdf form, then you have come on to correct site. We present the utter option of this ebook in PDF, epub,
More informationMECHANICAL EXHAUST VENTILATION SYSTEMS FOR RETAIL FOOD FACILITIES. Design, Calculations, and Operational Guidelines
MECHANICAL EXHAUST VENTILATION SYSTEMS FOR RETAIL FOOD FACILITIES California Conference of Directors of Environmental Health January 22, Page 1 of 30 TABLE OF CONTENTS I. Background 3 II. Purpose and Scope..3
More informationFOOD PREPARATION WITHIN EXHIBITS
FOOD PREPARATION WITHIN EXHIBITS Whenever food is prepared within an exhibit, an Application for Food Preparation within Exhibits form should be completed and forwarded to your Convention Services Manager
More informationConnected: Global protection, all together
Connected: Global protection, all together Connecting with customers like no others. Keeping people, property and your environment safe is the objective. And no one is equipped to help you reach it as
More informationKIDDE WHDR WET CHEMICAL FIRE SUPPRESSION AND INTELLIGENT CONTROL SYSTEM FOR COOKING OPERATIONS WITH ARIES-NET MULTI-LOOP INTELLIGENT CONTROL UNIT
1. GENERAL SPECIFICATION 1.1 This specification outlines the requirements for a pre-engineered fire extinguishing system comprising Kidde Fire Systems WHDR Wet Chemical Fire Suppression System, Kidde APC
More informationNFPA 101 Life Safety Code Culture change 2012
NFPA 101 Life Safety Code Culture change 2012 Produced by Kansas Fire Marshal April, 2012 On March 9, 2012 Centers for Medicare & Medicaid Services implements a policy where they have formally adopted
More informationREQUIREMENTS FOR HOOD PLANS
DEPARTMENT OF PUBLIC HEALTH Division of Environmental Health REQUIREMENTS FOR HOOD PLANS Submit one (1) set of plans drawn to scale of at least ¼-inch per foot. Plans shall conform to applicable California
More informationSuperior by Design The Kidde ADS TM FM-200 System
A UTC Fire & Security Company Superior by Design The Kidde ADS TM FM-200 System Engineered to Provide Exceptional Performance The Kidde ADS FM-200 System is an innovative system developed by Kidde engineers
More informationHYDROSTATIC TEST INSTRUCTIONS
HYDROSTATIC TEST INSTRUCTIONS STORED PRESSURE PORTABLE FIRE EXTINGUISHERS One Stanton Street / Marinette, WI 54143-2542, USA / +1-715-735-7411 Copyright 2017 Tyco Fire Products LP. All rights reserved.
More informationGlobal Property. SEMIANNUAL FIRE PROTECTION EQUIPMENT INSPECTION REPORT Date of Inspection Location:
Global Property SEMIANNUAL FIRE PROTECTION EQUIPMENT INSPECTION REPORT Plant: Date of Inspection Location: Inspected By: Reviewed By CONTROL VALVES (If Valves are Not Locked Open or Electronically Supervised
More informationWAS STARTED BY CARLOS BAHAMONDES MASAFIERRO
WWW.WATERMIST.CL WWW.WATERMIST.CL WAS STARTED BY CARLOS BAHAMONDES MASAFIERRO ALTHOUGH SOLUTIONS SUCH AS THESE ARE NOW MORE IMPORTANT THAN EVER IN TIMES OF SEVERE DROUGHT, CARLOS BAHAMONDES MASAFIERRO
More informationHydrostatic Retest Requirements for ANSUL Pressure Vessels
TECHNICAL BULLETIN Hydrostatic Retest Requirements for ANSUL Pressure Vessels Portables, Wheeled Units, and Pre-engineered Pressure Vessels One Stanton Street Marinette, WI 54143-2542, USA +1-715-735-7411
More informationSprinkler Solutions for Storage Applications
Sprinkler Solutions for Storage Applications Logistics and Distribution As storage facilities and their distribution methods have evolved, so have the challenges of protecting them. When installing a fire
More informationNew Construction Fire Inspection Process
New Construction Fire Inspection Process This document is intended to provide the Owner, Designer, and/or Contractor of new construction with an outline of required fire inspections and with the specific
More informationAPPLICATION FOR EXEMPTION FROM MECHANICAL VENTILATION
COUNTY OF MARIN ENVIRONMENTAL HEALTH SERVICES 3501 CIVIC CENTER DRIVE, RM 236 SAN RAFAEL, CA 94903 415.473.6907/ (Fax) 415.473.4120 www.marincounty.org/ehs APPLICATION FOR EXEMPTION FROM MECHANICAL VENTILATION
More informationSystem Test Report CLEAN AGENT
City of Black Hawk Fire Department 196 Clear Creek Street PO Box 68 Black Hawk, CO 80422-068 Office 303-582-0426 Fax 303-582-2229 www.cityofblackhawk.org System Test Report CLEAN AGENT Occupancy Information
More informationAFEX. fire suppression systems AFEXSYSTEMS.COM
AFEX fire suppression systems AFEXSYSTEMS.COM ABOUT US We are heavy equipment people specializing in fire protection. AFEX is uniquely positioned to meet your fire protection needs. We have dedicated 50
More informationTo expedite the plan review and inspection processes, please refer to the information below.
Guidelines: The goal of the Denison Fire Department is to assist its customers in understanding our submittal, plan review and inspection process and policies, as they pertain to new construction. Familiarity
More informationEVALUATION SUBJECT: FIRE SUPPRESSION RANGE HOOD DIVISION: MECHANICAL SECTION: COMMERCIAL-KITCHEN HOODS.
ICC-ES Report PMG-1293 Reissued 12/2016 This report is subject to renewal 12/2017 EVALUATION SUBJECT: FIRE SUPPRESSION RANGE HOOD DIVISION: 23 00 00 MECHANICAL SECTION: 23 38 13 COMMERCIAL-KITCHEN HOODS
More informationPURPLE K POWDER EXTINGUISHERS INSTALLATION, OPERATION, MAINTENANCE AND RECHARGE MANUAL
PURPLE K POWDER EXTINGUISHERS INSTALLATION, OPERATION, MAINTENANCE AND RECHARGE MANUAL NO. 05602 FOR AMEREX STORED PRESSURE, HAND PORTABLE DRY CHEMICAL FIRE EXTINGUISHERS. ABC (Ammonium Phosphate Base)
More informationLife Safety Code NFPA 10 NFPA 13 NFPA 25 NFPA 72 NFPA 90A NFPA 110 NFPA 99 THE 2012 EDITION OF THE LIFE SAFETY CODE HOSPITAL EDITION SESSION #7
THE 2012 EDITION OF THE LIFE SAFETY CODE HOSPITAL EDITION SESSION #7 AGENDA: Life Safety Code Referenced Publications Overview Life Safety Code NFPA 10 NFPA 13 NFPA 25 NFPA 72 NFPA 90A NFPA 110 NFPA 99
More informationK Series - Fire Suppression Systems for the Catering Industry
K Series - Fire Suppression Systems for the Catering Industry Technical Overview The System Concept The K-Series fire protection systems are fully engineered and as such are designed to meet the individual
More informationData/ Specification Sheet
Data/ Specification Sheet MONARCH Dry Chemical Automotive Paint Spray Booth Fire Suppression System TM 1. Fixed temperature mechanical or thermal detectors 2. Electrical conduit protecting stainless steel
More informationFIRE PROTECTION, NATURALLY AQUASONIC Water-Atomizing Fire Suppression System
FIRE PROTECTION, NATURALLY AQUASONIC Water-Atomizing Fire Suppression System A LOOK INSIDE THE INNOVATION The ANSUL AQUASONIC TM Water-Atomizing Fire Suppression System is a revolution in Class B fire
More informationPERFORMANCE AT HAND RED LINE Hand Portable Fire Extinguishers
PERFORMANCE AT HAND RED LINE Hand Portable Fire Extinguishers MODEL 5 The Model 5 has a slim design for use on vehicles and machinery where space is limited. Typical applications include small trucks,
More informationSECURITY BLANKET Foam Fire Protection Products
SECURITY BLANKET Foam Fire Protection Products REAL DANGERS DEMAND REAL SOLUTIONS If your business manufactures, stores, or transports flammable liquids, the thought of a devastating fire always burns
More informationGUILFORD COUNTY SCHOOLS
GUILFORD COUNTY SCHOOLS Fire Extinguisher Plan Policy In accordance with the regulations established by the United States Department of Labor pursuant to the Occupational Safety and Health Act and the
More informationAll temporary special events held within the City of Orlando must be approved and inspected by the Orlando Fire Department prior to holding the event.
December 15, 2005 Dear Event Planner: All temporary special events held within the City of Orlando must be approved and inspected by the Orlando Fire Department prior to holding the event. Applications
More informationAre Your Kitchen Hood Filters Compliant?
Are Your Kitchen Hood Filters Compliant? Do your kitchen hood filters comply with the current Australian Standards for fire safety? Why Install Kitchen Exhaust Hood Filters? The purpose of a kitchen exhaust
More informationSafer. Smarter. Tyco. I wish I had a flexible FM Approved Water Mist Solution to fit any industrial oil cooker.
I wish I had a flexible FM Approved Water Mist Solution to fit any industrial oil cooker. I wish I could protect my industrial fryer installation with a fire protection solution that helps minimize collateral
More informationPriceList Category PartNbr Part Description Weight (l MSRP
Date Printed :4/22/2014 12:04:43 PM Effective 4-MAR-2014 CATALOG PRICING Note:Price amounts shown are in US$ PriceList Category PartNbr Part Description Weight (l MSRP ANSUL Restaurant Systems PIRANHA
More informationModel ESFR K-factor Pendent Sprinkler Early Suppression, Fast Response General Description. Sprinkler Identification Number (SIN)
Worldwide Contacts www.tyco-fire.com Model ESFR-25 25.2 K-factor Pendent Sprinkler Early Suppression, Fast Response General Description TYCO Model ESFR-25 Pendent Sprinklers are Early Suppression, Fast
More informationContents Chapters 4 & 5 of the 2012 Michigan Mechanical Code CHAPTER 4, MMC: VENTILATION CHAPTER 5, MMC: EXHAUST SYSTEMS
Contents Chapters 4 & 5 of the 2012 Michigan Mechanical Code CHAPTER 4, MMC: VENTILATION CHAPTER 5, MMC: EXHAUST SYSTEMS 1 Ventilation and Exhaust 2 Seminar Introduction Seminar addresses key concepts
More informationInternational Fire Code 2006 Requirements for Construction Plan Reviews of Commercial and Multi-Family Structures
International Fire Code 2006 Requirements for Construction Plan Reviews of Commercial and Multi-Family Structures Please note this is not an all-inclusive list. The type and complexity of your project
More informationFIRE DEPARTMENT PERMIT GUIDELINES
FIRE DEPARTMENT PERMIT GUIDELINES SPECIAL EVENT PUBLIC ASSEMBLY (EACH EVENT) The Special Event Assembly Permit is applicable to any public event, exhibit space, booth, festival or any other similar event
More informationUMC 2012 ( ): Item # 38
UMC 2012 (504.3.1): Item # 38 Steve Taylor Taylor Engineering 504.3.1 Moisture Exhaust Ducts. Moisture exhaust ducts shall terminate on the outside of the building and shall be equipped with a back-draft
More informationChecklist For Building Inspection & Fire Safety
INSPECTION CHECKLIST Date of Inspection: Location/Address: Weather Condition: Inspector: AFTER COMPLETING YOUR INSPECTION, TRANSFER YOUR CONCERNS/OBSERVATIONS TO THIS AREA Facility: Name: Staff Contact:
More informationSPECIFICATION: ARGONITE Engineered Fire Suppression System
1. GENERAL SPECIFICATION 1.1 A total flooding, clean agent, fire suppression system, filled with Argonite agent shall be installed to meet a minimum design concentration of %, by volume in all designated
More informationFIre Extinguishers. K-GUARD Wet Chemical Fire Extinguishers Manual INSTALLATION 2014-DEC-29 REV. 03 PAGE 1 EXTINGUISHERS
K-GUARD Wet Chemical K-GUARD K-Guard WET CHEMICAL Wet Chemical EXTINGUISHERS FIre Extinguishers INSTALLATION 2014-DEC-29 REV. 03 PAGE 1 Installation, OPERATION, Recharge, and Maintenance Manual 004327
More informationWinnipeg Fire Department Fire Prevention Branch
Winnipeg Fire Department Fire Prevention Branch Manitoba Fire Code Life-Safety Equipment Maintenance Requirements The Fire Prevention Branch of the Winnipeg Fire Department has prepared this document of
More information