meter SKU-03 (calculator and flow sensor) Fig.2. Calculator of the heat meter SKU-03
|
|
- Karin Lee
- 5 years ago
- Views:
Transcription
1 LABORATORY OF HEAT EQUIPMENT Certificate Nr. LT-1621-Ml004-00S issued 29 th April2011 Page I of 9 pages Harmonized standards applied: LST EN :2007, LST EN AC:2007, LST EN :2009, LST EN AC:2007, LST EN :2007. Additionally documents applied: WELMEC Software guide (Issue 4). The measuring instrument must correspond with the following specifications: 1 Design of the instrument 1.1 Construction Heat meter SKU-03 consists of the primary flow sensor and the calculator with type approved pair of temperature sensors with Pt500 elements. Flow sensor consists of brass housing with the installed ultrasound transducers. The flow sensor connected to the calculator via screened cable. The flow sensors qp=(o,6-6,0)m 3 /h has intended place for temperature sensor. The calculator can be mounted directlyon a flow sensor or separately. The heat meter is operated by 3,6 V lithium battery. Fig.l.Heat meter SKU-03 (calculator and flow sensor) Fig.2. Calculator of the heat meter SKU-03 Breslaujos g. 3. LT Kaunas, tel.: (8-37) , fax: (8-37) , testlab@mail.lei.lt,
2 LABORATORY OF HEAT EQUIPMENT Certificate Nr. LT-1621-MI004-00S Page 2 of9 pages Fig.3. Flow sensor of the heat meter SKU-03, qp=o,6/1,0i1,512,5 mvh Fig.4. Flow sensor of the heat meter SKU-03, qe=3,5/6,o m 3 /h Fig.6. Flow sensor of the heat meter SKU-03, qp=15,o m 3 fh Breslaujos g. 3. LT Kaunas, tel.: (8-37) , fax: (8-37) , e-rnail: testlab@mail.lei.lt,
3 LABORATORYOFHEATEQUIPMENT Appendix to EC-Type Examination Certificate Nr. LT-1621-MI004-00S Type number combination of the heat meter SKU-03 Page 3 of 9 pages Type Installation of the flow sensor: Code In supply pipe 1 In return pipe 2 Destination of the meter: Code Meter for heating 1 (for measurina heatina energv onlv) Meter for heating and cooling 2 (for measuring heating and coollna eneray),-:r I SKU atio of flow-rate limits (qjqj): Limits of temperature differences Code 100 ( ) K ( ) K ( ) K ( ) K 4 I ,... Flow sensor: Perm. flow-rate, m"/h Overalllength, mm End connections Code 0,6 110 Go/.. 1 1,0 110 Go/.. 2 1,5 110 Go/.. 3 2,5 130 GI 4 3,5 260 G1Y.. 5 6,0 260 G1Y ,0 300 G2 7 10,0 300 DN ,0 270 DN50 9 Communication interface: None M-bus CL RF module 868 MHz Code o Measurand sensor The heat meter hardware consists of an ultrasonic flow sensor and heat meter calculator with the connected temperature sensors. The calculator measures the resistance of type approved pair of temperature sensors with Pt500 elements and converts it to temperature according to formulas of EN :2008. The calculator also measures the volume of the heat-conveying liquid by processing signals, received from the ultrasound transducers of the flow sensor. Breslaujos g. 3. LT Kaunas, tel.: (8-37) , fax: (8-37) , testlab@mail.lei.lt,
4 LABORATORYOFHEATEQUIPMENT Page 4 of 9 pages 1.3 Measurand processing The energy, consumed for heating (cooling), is calculated by integrating the temperature difference and the volume of the heat-conveying liquid over time. The temperature difference is calculated from the resistance of the temperature sensors pair, connected to the calculator. Integrated software version ofheat meter is "Soft 0.06". 1.4 Indication of the measurement result The accumulated quantity of thermal energy is presented on the display in the kwh. Other units (MWh, Gcal, GJ) can be chosen too. 1.5 Optional equipment and functions subject to MID requirements 1.6 Technical documentation Technical description, operating instruction, certificate PLSKU03VOl, l. Description of the integrated software structure PIASKU03MIDV01, Other reference documents on which basis this certificate is issued, are stored in a file Nr.LEI-12-MP Integrated equipment and functions not subject to MID 2 Technical data 2.1 Rated operating conditions Measurand Thermal (cooling) energy, calculated from the measured volume of water and the measured difference of water temperature in flow and retum pipes Measurement range For calculator: - limits of temperature E> min - E> max: ( )OC; - limits of temperature difference ~E> min - ~E> max: ( ) K or ( ) K - depending on the lower limit of the temperature difference of the connected pair oftemperature For flow sensor: Temperature limits ofheat conveying liquid: - for meters qp~ 2,5 m 3 fh E> q = 5 C 130 C; - for meters qp~ 3,5 m 3 fh E> q = 10 C.l30 "C, sensors. Breslaujos g. 3. LT Kaunas, tel.: (8-37)401863, fax: (8-37) , testlab@mail.lei.lt,
5 LABORATORYOFHEATEQUJPMENT issued 29 th Apri12011 Heat meter flow sensor technical data are presented in Table 1: Page 5 of9 pages Table 1 Flow-rate, mvh End connection Permanent ą p Maximum ąs Minimum ąj Overalllength, mm G3/4" 0,6 1,2 0, G3/4" 1,0 2,0 0, G3/4" 1,5 3,0 0, G3/4" 1,5 3,0 0, GI" 2,5 5,0 0, GI" 2,5 5,0 0, GI 1/4" 3,5 7,0 0, GI 114" 6,0 12,0 0, GI 114" 6,0 12,0 0, G2" ordn40 10,0 20,0 0, DN50 15,0 30,0 0, DN50 15,0 30,0 0, Accuracy c1ass Accuracy c1ass- 2 according to LST EN : Environmental conditions 1Influence quantities Ambient temperature +5 C to +55 C; Humidity non condensing; Location c1osed; Mechanical environment c1ass Ml; Electromagnetic environment c1ass E Other operating conditions Maximum admissible working pressure (c1ass PN) The maximum admissible working pressure ofheat meter is 16 bar (PNI6) Mounting position of the flow sensor of the heat meter Flow sensor can be mounted both vertically and horizontally. 3 Interfaces and compatibility conditions 3.1 Compatibility conditions 2 extra pulse inputs with programmable pulse value, c1ass of pulse input device -IB according to LST ENI434-2+AC: temperature measurement channels for connecting temperature sensors with Pt500 sensing elements and 2-wire connection method. Breslaujos g. 3. LT Kaunas, tel.: (8-37) , fax: (8-37) , testlab@mail.lei.lt,
6 LABORATORYOFHEATEQUIPMENT Page 6 of 9 pages 3.2 Interfaces Integrated optical communication interface according to LST EN :2003 requirements. 2 pulse outputs for remote data reading. Class of pulse output device-ob according to LST EN AC:2007. Additionally (as optional plug-in modules): - M-bus; - CL; MHz RF radio module. 4 Requirements on production, putting into use and utilization 4.1 Requirements on production No special requirements identified. 4.2 Requirements on putting into use The heat meter SKU-03 must be installed in accordance with the requirements of documents, listed in 1.6. Necessary straight line length for flow sensor installation in pipeline: no requirements for straight pipeline length in upstream and downstream q > 6 m3/h u stream straight pipeline len h ~ 5 x DN and downstream ~ 3 x DN Initial verification test of flow sensor can be carried out with cold water (25 ± 5) C. 4.3 Requirements for utilization 5 Control of the measuring process after tasks of the instrument in use 5.1 Documentation of the procedure 5.2 Special equipment or software 5.3 Identification of hardware and software 5.4 Calibration-adjustment procedure Breslaujos g. 3. LT Kaunas, tel.: (8-37) , fax: (8-37) , testlab@mail.lei.lt,
7 L4BORATORYOFHEATEQUIPMENT issued 29 th Apri12011 Page 7 of 9 pages 6 Security measures 6.1 Seating The following heat meter calculator sealing is provided: - manufacturer adhesive seal-sticker on the fixing bolt of electronic module and access to the adjustment activation jumper (see Fig.7, pos.l) and on the fixer of the cover protecting electronic module (see Fig.7, pos.2); - two hanged seals on the fixers of junction of the case and cover of the calculator (see Fig. 7, pos.3) are arranged after installation. 1 2 Fig.7. Sealing of the calculator ofthe heat meter SKU-03 The following flow sensor sealing is provided: - manufacturer adhesive warranty seal-sticker on the bolts of the cover (see Fig.8, Fig.9, Fig.lO, Fig.ll); Manufacturer's adhesive warranty seal Manufacturer's adhesive warranty seal Fig. 8. Sealing of flow sensor of the heat meter SKU-03, ąp=o,611,0i1,5/2,5 rnvh Fig. 9. Sealing of flow sensor of the heat meter SKU-03, ąp=3,5/6,o rnvh Breslaujos g. 3. LT Kaunas, tel.: (8-37)401863, fax: (8-37) , testlab@mail.lei.lt,
8 LABORATORY OF HEAT EQUIPMENT Page 8 of9 pages Manufacturer's adhesive warranty seal Manufacturer's adhesive warranty seal Fig. 10. Sealing of flow sensor of the heat meter SKU-03, qp=10,o m 3 fh Fig. 11. Sealing of flow sensor of the heat meter SKU-03, qp=15,o mvh I(~(sI a) Manufacturer security seal- adhesive sticker I'A2EIDUS GARAHTIJA NEGALIOJA WARRANTY VOlD le' REMOVEO / AXISlndustr1es 11 / b) Manufacturer warranty seal- adhesive sticker Fig.12. Examples of security seals 6.2 Data logger Archive data retention time is at least 12 years. 7 Marking and inscriptions 7.1 Information to be borne by and to accompany the measuring instrument The following information shall appear in legible and indelible characters on the heat meter calculator casing or his label: EC-type examination certificate number (LT-1621-MIO04-005); manufacturer name or his trade mark; identity marking (type designation and type number); year of manufacture and serial number; limits of the temperature; limits oftemperature differences; limits of heat conveying liquid temperature; Breslaujos g. 3. LT Kaunas, tel.: (8 37) , fax: (8 37) , e-rnail: testlab@mail.lei.lt,
9 LABORA TORY OF HEAT EQUIPMENT Page 9 of 9 pages type of temperature sensors (pt500); limits of flow-rate: maximum ą s' permanent ą p and minimum ą;; the maximum admissible working pressure (PN class); flow sensor to be installed in the flow or retum; accuracy class; climatic class; electromagnetic class; mechanical class. Arrow to indicate the direction of the flow shall appear on flow sensor housing. 7.2 Conformity marking In addition, the label of heat meter calculator should contain the following marking: - "CE" marking; - metrology marking, consisting of the cap ital letter "M" and the last two digits of the year of its affixing, surrounded by a rectangle; - identification number of the notified body, which carried out the conformity assessment. 8 List of the drawings attached to the certificate. Drawings are not added. 9 Certificate history Issue Nr. Date Description LT-1621-MI Type examination certificate first issued Breslaujos g. 3. LT Kaunas, tel.: (8-37) , fax: (8-37) , testlab@mail.lei.lt,
EU-TYPE EXAMINATION CERTIFICATE
0402-MID-385402 Water meter Vesiverto V-15M Issued to: Address: Vercon Oy Hopunkatu 11, FI38200, SASTAMALA, Finland In respect of (type of instrument) Water meter for cold (T30) and hot water (T30/90).
More informationEU-Type Examination Certificate
EU-Type Examination Certificate Measuring Instrument Directive Certificate number: 0200-MID-02784 Issued by FORCE Certification A/S, Denmark EU-notified body number 0200 In accordance with the Directive
More informationCertificate of EC type-examination of a measuring instrument Number: UK/0126/0077 Revision 1
(UK/0126/0077) MI-001 United Kingdom of Great Britain and Northern Ireland Certificate of EC type-examination of a measuring instrument Number: UK/0126/0077 Revision 1 issued by the Secretary of State
More informationULTRAFLOW 54 DN
Data sheet ULTRAFLOW 54 DN150-300 For flow from 150 m³/h up to 1000 m³/h Ultrasonic flow sensor Compact design Static meter, no moving parts Large dynamic range No wear High accuracy Longevity MID-2004/22/EC
More informationEW447-EW452 Series Mechanical Heat Meters FOR HEATING AND COOLING APPLICATIONS
Design Hydronic meters of the EW447-452 Series consist of: Electronic energy integrator with fixed cable connection to the volume measuring component, supply and return temperature probe Mechanical volume
More informationEW171 Series Woltman Bulk Water Meters DN FOR COLD AND WARM POTABLE WATER APPLICATIONS
EW171 Series Woltman Bulk Water Meters DN50 300 FOR COLD AND WARM POTABLE WATER APPLICATIONS CONTENTS PRODUCT DATA EW171, DN50 Contents... 1 General... 2 Application... 2 Features... 2 Design... 2 Materials...
More informationEC PARTS CERTIFICATE GB-1432
EC PARTS CERTIFICATE GB-1432 Issued by: National Measurement Office The equipment has been examined in accordance with WELMEC Guide 8.8 Issue 1 (General and Administrative Aspects of the Voluntary System
More informationMetering systems 0670EN March 2017 Volumetric thermal energy meters for use in a boiler room GE552-1 series
Threaded version Flanged version GE552-1 Description The GE552-1 volumetric meters are used in the boiler room, to measure the heating and conditioning energy. They are strongly recommended for energy
More informationApplications. Features & Benefits ULTRASONIC WATER METER
MEASURE TODAY. ENSURE TOMORROW wprime TM Series 280W-CI Spire Metering offers the latest in Commercial/Industrial ultrasonic metering technology for reliable flow measurement. The rugged 280W-CI water
More informationDirective and standards of DHC-metering
NORDISK FJERNVÄRMESYMPOSIUM ÅLESUND, 12. 15. JUNI Tuesday, 15. June 2004 Directive and standards of DHC-metering Veikko Hokkanen, Helsinki Energy The MID Directive of the European Parliament and of the
More informationMARINE GYRO COMPASS STANDARD FOR CERTIFICATION. DET NORSKE VERITAS Veritasveien 1, N-1322 Høvik, Norway Tel.: Fax:
STANDARD FOR CERTIFICATION No. 2.9 MARINE GYRO COMPASS JANUARY 2003 Veritasveien 1, N-1322 Høvik, Norway Tel.: +47 67 57 99 00 Fax: +47 67 57 99 11 FOREWORD is an autonomous and independent Foundation
More informationAnalog Annunciator Unit SACO 16 A3. Product Guide
Issued: Aprill 1999 Status: Updated Version: C/20.03.2006 Data subject to change without notice Features Powerful, flexible and field-customizable 16-channel analog input signal annunciator unit A full
More informationMetering Box METERING AND AMBIENT HEATING FOR HEATING SYSTEM. Overview. Application PRODUCT DATA
Metering Box METERING AND AMBIENT HEATING FOR HEATING SYSTEM Overview PRODUCT DATA The Honeywell Substations series consist of the following products: Metering Box (this datasheet) Heat Interface Unit,
More informationClampOn DSP Corrosion- Erosion Monitor
ULTRASONIC INTELLIGENT SENSORS ClampOn DSP Corrosion- Erosion Monitor DIGITAL SIGNAL PROCESSING ULTRASONIC INTELLIGENT SENSORS ClampOn DSP Corrosion-Erosion Monitor The patented ClampOn DSP Corrosion-Erosion
More informationDatasheet PDCSY-MW-MD. Technical Overview. Features. Product warranty and total quality commitment. Heat Meter Integrator
Datasheet Heat Meter Integrator Technical Overview The range of Heat Meter Integrators uses the latest innovative technology to calculate heat usage from heating and cooling systems. They are for use with
More informationaquaconcept Cold water
aquaconcept Cold water Applications The unique aquaconcept modular design covers a wide range of water applications. This innovative system offers all types of water measurement right up to data integration
More informationCouncil Directive 93/68/EEC of 22 July 1993 amending Directives
Council Directive 93/68/EEC of 22 July 1993 amending Directives 87/404/EEC (simple pressure vessels), 88/378/EEC (safety of toys), 89/106/EEC (construction products), 89/336/EEC (electromagnetic compatibility),
More informationRADAR REFLECTOR STANDARD FOR CERTIFICATION. DET NORSKE VERITAS Veritasveien 1, N-1322 Høvik, Norway Tel.: Fax:
STANDARD FOR CERTIFICATION No. 2.9 RADAR REFLECTOR JANUARY 2003 Veritasveien 1, N-1322 Høvik, Norway Tel.: +47 67 57 99 00 Fax: +47 67 57 99 11 FOREWORD is an autonomous and independent Foundation with
More informationSonoSelect and SonoSafe Energy Meters
Installation & User Guide Energy Meters 09/2017 Danfoss VUIGB802 1 www.heating.danfoss.com Danfoss A/S DK-6430 Nordborg Denmark CVR nr.: 20 16 57 15 Telephone: +45 7488 2222 Fax: +45 7449 0949 EU DECLARATION
More informationPRODUCT CONFORMITY CERTIFICATE
PRODUCT CONFORMITY CERTIFICATE HydroRanger 200 Controller (segmented display or HMI display) with Echomax XRS-5 ultrasonic level transducer manufactured by: Siemens Canada Ltd. Siemens Milltronics Process
More informationSECTION ULTRASONIC TRANSIT TIME CLAMP-ON FLOW MEASURING SYSTEM
SECTION 40 71 66 ULTRASONIC TRANSIT TIME CLAMP-ON FLOW MEASURING SYSTEM PART 1-GENERAL 1.01 SUMMARY A. Ultrasonic clamp-on flow measurement system designed for non-intrusive external to pipe measurement
More informationÉDANAK PROD Reg. No. 7025
PROD Reg. No. 7025 EC-Type Examination Ceftificate Measuring Instrument Directive Ceftificate number: DK-0200-MI004-0O9 Issued by A/S, Denmark EC-notified body number 0200 In accordance with The Danish
More informationChain saws (electric mains powered and battery powered)
Compliance Guide Edition 09/2016 Chain saws (electric mains powered and battery powered) European Garden Machinery Federation EGMF Bd Reyers 80, 1030 Brussels, Belgium secretariat@egmf.org +32 2 206 68
More informationImplementation of the Construction Products Regulation (CPR) in harmonized standards - Template for Annex ZA -
TF N 530 Rev.2 2012-04-13 CONSTRUCTION SECTOR STANDARDIZATION GUIDANCE DOCUMENT Implementation of the Construction Products Regulation (CPR) in harmonized standards - Template for Annex ZA - 1 Drafting
More informationSubstation Monitoring System
Substation Monitoring System UHF Partial Discharge Monitoring System Description Introduction The UHF PDM System is the third generation, spanning 20 years, of monitoring systems developed for GIS partial
More informationMagnetic-Inductive Flow Velocity Sensor PIT. Installation and Operating Instructions
Magnetic-Inductive Flow Velocity Sensor PIT Installation and Operating Instructions Table of contents 1 IDENTIFICATION... 3 1.1 Manufacturer/supplier... 3 1.2 Product type... 3 1.3 Product name... 3 1.4
More informationCT398 Heaterstat TM Temperature Controller. Technical User Guide
CT398 Heaterstat TM Temperature Controller Technical User Guide CT398 HeaterStat Controller Contents CT398 HeaterStat Controller... 2 Contents... 2 Document Overview... 2 For More Information... 2 Introduction...
More informationEC 350 PTZ Gas Volume Correctors Enabling Precision Gas Measurement
EC 350 PTZ Gas Volume Correctors Enabling Precision Gas Measurement Proven Technology. Superior Performance. Local gas distribution companies supplying commercial and industrial customers require gas measurement
More informationSUPPLEMENTARY REGULATIONS SPECIFIC TO CERTIFICATION OF PERSONAL PROTECTIVE EQUIPMENT (PPE)
SUPPLEMENTARY REGULATIONS SPECIFIC TO CERTIFICATION OF PERSONAL PROTECTIVE EQUIPMENT (PPE) SCS/SF/053-8 Issue 1 Sira Certification Service INTRODUCTION One of the conditions placed on all holders of Sira
More informationSensor Technology. Summer School: Advanced Microsystems Technologies for Sensor Applications
Sensor Technology Summer School: Universidade Federal do Rio Grande do Sul (UFRGS) Porto Alegre, Brazil July 12 th 31 st, 2009 1 Outline of the Lecture: Philosophy of Sensing Thermal Sensors Chemical Sensors
More informationaquaconcept Cold water
aquaconcept Cold water Applications The unique aquaconcept modular design covers a wide range of water applications. This innovative system offers all types of water measurement right up to data integration
More informationMagnetic-Inductive Flow Velocity Sensor PIT. Device Description
Magnetic-Inductive Flow Velocity Sensor PIT Device Description Table of contents 1 IDENTIFICATION...3 1.1 Manufacturer/supplier...3 1.2 Product type...3 1.3 Product name...3 1.4 Issue date...3 1.5 Version
More informationAnnunciator Unit SACO 16 D1. Product Guide
Issued: Aprill 1999 Status: Updated Version: C/20.03.2006 Data subject to change without notice Features Flexible, field-customizable 16-channel annunciator unit Alarm channels activated by normally open
More informationFLOOD SERIES DATA SHEET
FLOOD SERIES DATA SHEET Instr strument mentation tion for Science and a Industry try ISI sa-nv Rue du Doyenné 3-1180 Brussels Tel +32 (0) 2 343 30 81 Fax 02/ 343 12 05 web : http:// www.isi-be.com mail
More informationSonoSelect and SonoSafe energy meters
energy meters 03/2016 Danfoss VUIGB402 1 Danfoss A/S DK-6430 Nordborg Denmark CVR nr.: 20 16 57 15 Telephone: +45 7488 2222 Fax: +45 7449 0949 EC/EU DECLARATION OF CONFORMITY Danfoss A/S Danfoss Energy
More informationGuidance Note No 21/1. CE Marking Windows and doorsets to BS EN 16034
Guidance Note No 21/1 CE Marking Windows and doorsets to BS EN 16034 Introduction CE Marking of construction products has been a legal requirement since July 2013. It is a European requirement for all
More informationAUGUST 2016 CONTENTS:
EMC SERVICES NEWSLETTER AUGUST 2016 CONTENTS: RECENT STANDARD CHANGES NEW FCC REGULATIONS IEC 60601-1-2 4TH EDITION LOW VOLTAGE DIRECTIVE EU DIRECTIVES EMC DIRECTIVE 2014/30/EU KOREA UPDATE: KN32/35 1.
More informationGas Detection System TOX ALARM DG2000-Garage
Gas Detection System TOX ALARM DG2000-Garage Gas Detection System 32 independent programmable channels 2 programmable alarm levels for each gas = up to 6 for each channel LCD alphanumeric display of gas
More informationLawnmowers (pedestrian controlled, battery powered)
Compliance Guide Rev.01, Edition 04/2018 Lawnmowers (pedestrian controlled, battery powered) European Garden Machinery Federation EGMF Bd Reyers 80, 1030 Brussels, Belgium secretariat@egmf.org +32 2 206
More informationExternal Dimensions: B = 600 mm D = 630 mm H = 2000 mm. Internal Dimensions: B = 451 mm D = 430 mm H = 1598 mm
External Dimensions: B = 600 mm D = 630 mm H = 2000 mm Internal Dimensions: B = 451 mm D = 430 mm H = 1598 mm Capacity: 328 l Temperaturerange: -15 C to -30 C Housing galvanized sheet steel with white
More informationConnected Industrial. EC 350 PTZ GAS VOLUME CORRECTORS ENABLING PRECISION GAS MEASUREMENT Proven Technology. Superior Performance.
Connected Industrial EC 350 PTZ GAS VOLUME CORRECTORS ENABLING PRECISION GAS MEASUREMENT Proven Technology. Superior Performance. Local gas distribution companies supplying commercial and industrial customers
More informationLawn trimmers and lawn edge trimmers (hand held electric mains powered)
Compliance Guide Edition 09/2016 Lawn trimmers and lawn edge trimmers (hand held electric mains powered) European Garden Machinery Federation EGMF Bd Reyers 80, 1030 Brussels, Belgium secretariat@egmf.org
More informationSECTION Fluorescent Dissolved Oxygen Measuring System
SECTION 40 75 43 Fluorescent Dissolved Oxygen Measuring System PART 1 General 1.01 SUMMARY A. Requirements for a high-performance, digital fluorescence sensor for measurement of dissolved oxygen in liquid.
More informationLawnmowers, pedestrian controlled (combustion engine powered)
Compliance Guide Rev.1, 09/2016 Lawnmowers, pedestrian controlled (combustion engine powered) European Garden Machinery Federation EGMF Bd Reyers 80, 1030 Brussels, Belgium secretariat@egmf.org +32 2 206
More informationRobotic Mowers (battery powered and charging station connected to electric mains or low voltage supply)
Compliance Guide Edition 05/2018 Robotic Mowers (battery powered and charging station connected to electric mains or low voltage supply) European Garden Machinery Federation EGMF Bd Reyers 80, 1030 Brussels,
More informationTechnical Information OUSAF21
TI00471C/07/EN/02.16 71316927 Products Solutions Services Technical Information Optical sensor for the measurement of low color concentrations Application The sensor is used to measure color concentrations
More informationLevel Measurement Continuous level measurement - Ultrasonic transmitters
Overview Configuration Parabolic mounting is a 2-wire loop powered ultrasonic transmitter for level, volume and flow monitoring of liquids in open channels, storage vessels, and simple process vessels.
More informationThe New EMC Directive 2004/108/EC
The New EMC Directive 2004/108/EC In the process of this review I have tried to spell out in words what is often referred to as a section number while also keeping to location information as used in the
More informationThe Impact of Marking Requirements. on Design and Performance of Power Converters and Electrical Drives
European The Impact of Marking Requirements on Design and Performance of Power Converters and Electrical Drives Harmonization of Standards The Key to the European Market C onfused E urope EN 600204 BS...
More informationCO-ORDINATION OF NOTIFIED BODIES PPE Regulation 2016/425 RECOMMENDATION FOR USE
CO-ORDINATION OF NOTIFIED BODIES PPE Regulation 2016/425 PPE-R/00.017 Version 2 RECOMMENDATION FOR USE Number of pages: 5 Approval stage : Approved on : Origin : Horizontal Committee, C2D Ad hoc group
More informationThe New EMC Directive 2004/108/EC
The New EMC Directive 2004/108/EC In the process of the review I have tried to spell out in words what is often referred to as a section number. This helps reduce the need to flip pages as one reads this.
More informationDIRECT AND INDIRECT THERMAL ENERGY METERING
Chapter 7 DIRECT AND INDIRECT THERMAL ENERGY METERING User modules for direct metering 232 Heat interface units for direct metering 236 Thermal energy meters, water maters, data centralization system 243
More informationChapter 7 DIRECT AND INDIRECT THERMAL ENERGY METERING
Chapter 7 DIRECT AND INDIRECT THERMAL ENERGY METERING 7 216 USER MODULES FOR DIRECT METERING GE555 STANDARD CONNECTIONS DIMENSIONS (L x H x D) mm BALANCING UNITS FOR SANITARY WATER METERS GE555Y461 3/4
More informationSECTION Process and Immersion Turbidity and Total Suspended Solids Sensor
SECTION 40 75 53 Process and Immersion Turbidity and Total Suspended Solids Sensor PART 1 General 1.01 SUMMARY A. Requirements for a digital sensor for process turbidity or Total Suspended Solids (TSS)
More informationKrypton K CL2. Measuring and control system for free chlorine. applications. description. Low maintenance by automatic sensor cleaning
Low maintenance by automatic sensor cleaning Pressure-proof up to 6 bar at 20 C Higher safety by integrated flow monitoring applications Drinking Water / Beverages Food Industry Disinfection Cooling And
More informationAnnunciator unit. Application
Issued: April 1999 Status: April 1999 Version: B/09.11.2001 Data subject to change without notice Features Flexible, field-customizable 16-channel annunciator unit Alarm channels activated by normally
More informationMultiMeter 44. Transmitter-regulator with 1, 2 or 3 channels. Quality at a reasonable price
MultiMeter 44 Transmitter-regulator with 1, 2 or 3 channels MultiMeter 44 is a modular meter that can be configured with one, two or three channels. It can be delivered with only one measuring channel,
More informationCertificate: / 29 April 2014
Test report: 936/21217455/A of 10 September 2013 Initial certification: 01 April 2014 Expiry date: 31 March 2019 Publication: BAnz AT 01 April 2014 B12, chapter I, No. 1.1 Approved application The tested
More informationGarden blowers, vacuums and blower/vacuums (electric mains powered)
Compliance Guide Rev.01, Edition 04/2018 Garden blowers, vacuums and blower/vacuums (electric mains powered) European Garden Machinery Federation EGMF Bd Reyers 80, 1030 Brussels, Belgium secretariat@egmf.org
More informationEL-OEM-3 OEM Packaged Voltage Data Logger
FEATURES PCB Mounted (2.54mm pitch, header sockets) 0 to 2.4V d.c. Measurement Range Logging Rates between 1s and 12hr Stores 64,000 readings USB interface for set-up and data download (USB connector not
More informationLawnmowers (pedestrian controlled electric mains-powered)
Compliance Guide Rev.2, Edition 04/2018 Lawnmowers (pedestrian controlled electric mains-powered) European Garden Machinery Federation EGMF Bd Reyers 80, 1030 Brussels, Belgium secretariat@egmf.org +32
More informationTechnical Information OUSAF44
TI00416C/07/EN/13.16 71316935 Products Solutions Services Technical Information Optical sensor combined with the OUA260 flow assembly for the measurement of UV absorption Application The sensor measures
More information1S25. Arc Fault Monitor 4 Zones, 8 Sensors. Features. Introduction. ARC Fault Protection
Technical Bulletin Arc Fault Monitor 4 Zones, 8 Sensors Features Four independent arc fault tripping zones 1 or 2 arc fault sensors per zone allowing up to 8 arc fault sensors per module Trip indication
More informationDMFPM-2R MULTIFUNCTIONAL
Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 4 OPERATIONAL DIAGRAMS 5 WIRING AND
More informationContinuous level measurement Ultrasonic transmitters
Overview Configuration Parabolic mounting is a 2-wire loop powered ultrasonic transmitter for level, volume and flow monitoring of liquids in open channels, storage vessels, and simple process vessels.
More informationPROGRAMMABLE 7-DAY RF THERMOSTAT
PROGRAMMABLE 7-DAY RF THERMOSTAT Installation and user instruction This instructions to be retained by the user 1 Thank you for choosing Beretta s radio frequency (RF) Radiostat. This central heating control
More informationPRODUCT CONFORMITY CERTIFICATE
PRODUCT CONFORMITY CERTIFICATE This is to certify that the SITRANS F M MAG 5100W Electromagnetic Flowmeter with MAG 5000, MAG 6000 or MAG 6000 Industry Transmitter DE-76181 Karlsruhe Germany manufactured
More informationTechnical Information OUSAF22
TI00472C/07/EN/02.16 71316931 Products Solutions Services Technical Information OUSAF22 Optical sensor combined with the OUA260 flow assembly for the measurement of color concentrations Application The
More informationArchitectural and Engineering Specification for a. Flash / Flare
Architectural and Engineering Specification for a Flash / Flare June 27, 2014 Page 1 of 12 T1DA0115-001 Rev D This document is intended to provide performance specifications and operational requirements
More informationInstallation & Operating Instructions
FH-RT Wireless Room Thermostat FH-BU Wireless Base Unit Installation & Operating Instructions Specification Base unit (230 V) Order Code: Primary voltage: Secondary voltage: Outputs 1-6: Outputs 7-8: 088H011901
More informationSECTION INDUCTIVE CONDUCTIVITY ANALYZERS
SECTION 40 75 16 INDUCTIVE CONDUCTIVITY ANALYZERS PART 1 General 1.01 SUMMARY A. Requirements for a digital inductive conductivity sensor for standard, hazardous and hightemperature applications. The sensor
More informationwww. ElectricalPartManuals. com Annunciator unit Features Self-contained microprocessor-based annunciator unit with 64 alarm channels Application
Features Self-contained microprocessor-based annunciator unit with 64 alarm channels pplication larm channels activated by normally open or normally closed contact Small and large stand-alone annunciator
More informationABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements
Specifications COMMANDER 150 Universal Process Indicator High visibility 6-digit LED display the clearest view of your process status 0.1% measurement accuracy precise indication of process measurement
More informationChromatographic Air circulated Refrigerator, two-door TC 603
External Dimensions: B = 1500 mm T = 700 mm H = 2100 mm Internal Dimensions: B = 1345 mm (clear door with: 545 mm) T = 570 mm H = 1330 mm (lower edge of evaporator) Capacity: 1000 l Temperature Range:
More informationDataSheet. Thermocouple Logger
DataSheet Thermocouple Logger For Type K, J, T & N Standard & miniature plugs Burnout response Cost-effective The Tinytag Ultra 2 Thermocouple data logger uses a thermocouple sensor for the cost-effective
More informationTinytag Ultra Data Logger Manual
Gemini Data Loggers Tinytag Ultra Data Logger Manual The name TINYTAG covers a range of miniature dataloggers used to aid the collection and monitoring of data. TINYTAG ULTRA loggers offer many features
More informationQFM41.. Duct sensors QFM41.. AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates
1 883 1883P01 1883P02 1859P04 QFM41.. AQF4150 AQF3153 Symaro Duct sensors for relative humidity and temperature with calibration certificates QFM41.. Operating voltage AC 24 V / DC 13.5...35 V Signal output
More informationDataSheet. Thermocouple Logger
DataSheet Thermocouple Logger For Type K, J, T & N Standard & miniature plugs Burnout response Cost-effective The Tinytag Ultra 2 Thermocouple data logger uses a thermocouple sensor for the cost-effective
More informationMiniature Infrared Temperature Sensors with Optional Touch Screen Display. PSC-SSS-PM with touch screen display (-CRT version)
PSC-SSS-PM Series Miniature Infrared Temperature Sensors with Optional Touch Screen Display PSC-SSS-PM with touch screen display (- version) FEATURES Miniature sensing head and configurable electronics
More informationYarway Narvik Steam Desuperheater Series 4300 TempLow
For precise and economical control of steam temperature Features and benefits Easy installation Installation in straight, vertical or horizontal pipe. Minimal headroom is required for mounting Only standard
More informationSIMPLIFIED VOYAGE DATA RECORDER (S-VDR)
STANDARD FOR CERTIFICATION No. 2.9 SIMPLIFIED VOYAGE DATA RECORDER (S-VDR) APRIL 2009 Veritasveien 1, NO-1322 Høvik, Norway Tel.: +47 67 57 99 00 Fax: +47 67 57 99 11 FOREWORD (DNV) is an autonomous and
More informationDuct Sensors. Siemens Building Technologies HVAC Products. Symaro. for relative humitidy (high accuracy) and temperature
1 882 1882P01 Symaro Duct Sensors for relative humitidy (high accuracy) and temperature QFM31 Use Examples Operating voltage AC 24 V / DC 1353 Signal output DC 010 V / 4 20 ma for relative humidity and
More informationEC100. Thermal Imaging System for Quality Control in Extrusion Processes EC100 PROCESS IMAGING SYSTEM
EC100 PROCESS IMAGING SYSTEM ENGLISH EC100 Thermal Imaging System for Quality Control in Extrusion Processes The EC100 provides real time temperature analysis for extrusion coating processes. (Photo: Courtesy
More informationSintrol Snifter A2 EX. Manual. Version 1.2.3
Sintrol Snifter A2 EX Manual Version 1.2.3 Table of Contents 1 INTRODUCTION... 3 1.1 Safety... 3 1.2 Product overview... 4 1.3 How does it work?... 4 2 INSTALLATION... 4 2.1 Selecting the installation
More informationIndustrial Strength Leak Detection
Industrial Strength Leak Detection Don t let an undetected leak or spill ruin the environment or your reputation... TraceTek Technology: Find leaks before major damage is done... TraceTek Technology: Sensor
More informationThe Role of Market Surveillance
Certification and Marking for Europe The Role of Market Surveillance Jan Deconinck, M.Sc. PROSAFE Chairman 1. Marks 1. Marks 1. Marks - It is prohibited to affix other markings or marks which might be
More informationLevel instruments. Continuous level measurement - Ultrasonic transmitters. SITRANS Probe LU. Overview. Configuration
Overview Configuration is a 2-wire loop powered ultrasonic transmitter for level, volume and flow monitoring of liquids in open channels, storage vessels and simple process vessels. Benefits Continuous
More informationTrade Product List 2013 BIOMASS ACCESSORIES
Trade Product List 2013 BIOMASS ACCESSORIES BIOMASS SYSTEM COMPONENTS Constant Temperature Control Accessories CONSTANT TEMPERATURE CONTROL PRODUCTS Order Code Description of Package and Contents Pictures
More informationUltrasonic Level Measurement nivopuls FDU 10 S
Technical Information TI 275F/00/en Ultrasonic Level Measurement nivopuls FDU 10 S Level limit switch for liquids with separate electronics unit Non-contact from outside Suitable for use in explosion hazardous
More informationMaterials Handling and Intralogistics. Industrial Trucks. In accordance with the Directive Equipment for potentially explosive atmospheres (ATEX)
Materials Handling and Intralogistics Industrial Trucks In accordance with the Directive Equipment for potentially explosive atmospheres (ATEX) LEGAL NOTICE 1 Legal notice The guideline Industrial Trucks
More informationEN - english. Instructions for installation and operation. Mobile humidity meter DP 207
EN - english Instructions for installation and operation Mobile humidity meter DP 207 Dear customers, Thank you very much for deciding in favour of the mobile humidity measuring instrument DP 207. Please
More informationUltrasonic Flowmeters SITRANS F US SONO Operating instructions 01/2010 SITRANS F
Ultrasonic Flowmeters Operating instructions 01/2010 SITRANS F SITRANS F Flowmeters Operating Instructions Introduction Safety notes Description Installing/Mounting Electrical connection Maintenance and
More informationGROUNDING AVOIDANCE SYSTEM (GAS)
STANDARD FOR CERTIFICATION No. 2.9 GROUNDING AVOIDANCE SYSTEM (GAS) JANUARY 2003 Veritasveien 1, N-1322 Høvik, Norway Tel.: +47 67 57 99 00 Fax: +47 67 57 99 11 FOREWORD is an autonomous and independent
More informationSITRANS. Temperature transmitter Functional safety for SITRANS TW. Introduction. General safety instructions 2. Device-specific safety instructions
Introduction 1 General safety instructions 2 SITRANS Temperature transmitter Device-specific safety instructions 3 Appendix List of Abbreviations/Acronyms A B Product Information Supplement to Operating
More informationCertificate: _01 / 20 August 2013
Test report: 936/21218492/B of 22 January 2013 Initial certification: 05 March 2013 Expiry date: 04 March 2018 Publication: BAnz AT 23 July 2013 B4, chapter II, No. 2.2 Approved application The tested
More informationShipboard incinerators with capacities up to 4000 kw
STANDARD FOR CERTIFICATION No. 2.9 Approval Programmes Type Approval Programmes for Marine Equipment Directive (MED) No. 431.90 - MED A.1/2.7 Shipboard incinerators with capacities up to 4000 kw JANUARY
More informationPRODUCT CONFORMITY CERTIFICATE
PRODUCT CONFORMITY CERTIFICATE This is to certify that the D-R 290 Opacity and Dust Concentration Monitor manufactured by: DURAG GmbH Kollaustraße 105 22453 Hamburg Germany has been assessed by Sira Certification
More informationÜntel is ready for CPR
2016 Üntel is ready for CPR Hakan Kubas Marketing Manager 01.11.2016 Construction Products Regulation What is the CPR? The Construction Products Regulation (CPR) lays down conditions for the placing or
More informationPQS performance specification
PQS performance specification WHO/PQS/E006/TH06.2 Original: English Distribution: General TITLE: Integrated electronic thermometer, with or without alarm function, for vaccine refrigerators and freezers
More informationSECTION Free/Available Chlorine Analysis System
SECTION 40 75 21 Free/Available Chlorine Analysis System PART 1 General 1.01 SUMMARY A. Requirements for a digital sensor system for free chlorine measurement for disinfection purposes in drinking water,
More information