1 IVA7008 الجه از : : اجر : LEVEL METER - FFT ANALYZER - : Auto Range - - -

2 Communication Options IVA : : IPSC-40 : ISO

3 IVA7008 IVA7008. : - (Level)... (Spectrum Analysis). IVA7008. (Enter. (LCD) : - (Cursor) ) ( - ). (Navigation) ESC F2 ( ) F3 ESC.. (9-pin - ( - ) (SERIAL I/O) DIB). (CHANNEL 1) (REFERENCE).

4 IVA7008 IVA7008 ( - )... IVA7008 ( - )

5 IVA7008 CHANNEL1 CHANNEL2 REFERENCE SERIAL I/O IVA7008 ( - ) ( - ) : - ( - ) (Statusbar) HI INS CAP :

6 IVA7008 :DO READING (. :DATA REVIEW (. :LOAD/DOWNLOAD (. :ADD NEW CASE (. :CONFIGURATION (. :IVA UTILITIES (. :FFT ANALYZER (. (FFT SPECTRUM ANALYZER) :LEVEL METER (.. :SPEED DETECT (. :PICKUP OPTION ( WELCOME TO IVA-6108 FFT DATA ANALYZER VER COPYRIGHT(C) 2003 S/N:00052 DO READING DATA REVIEW LOAD/DOWNLOAD ADD NEW CASE IVA OPTIONS IVA UTILITIES FFT ANALYZER LEVEL METER SPEED DETECT PICKUP OPTION 11/4/01 01:15:12 ( - )

7 IVA7008 Size : 26X18.5X7 cm 3 Weight : ~2.5 kg (with Battery) Color : White+Gray Casing : Plastic covers (HDPE) Input voltage : ±17 V Input impedance (without using UHR-5) : 133 kω Input capacitance ( = = = ) : 1 pf Frequency range : DC-60 khz Reference Signal Range : 0 to 12 V ITEM MAX. MIN. UNIT Battery voltage Power consumption Battery life* Operating temp. Storage temp VDC W Hour C C *: This life between two successive charges - : ( : ( : -

8 IVA7008 : IVA7008 : - (Accelerometer). IVA Vamos 3.20 ADD NEW CASE - -. : -. Groups RD (Resonance Detection). (400) IVA7008 (1060).(VAMOS). Level.

9 IVA7008 DEFINE GROUP SET MACHINE NAME SET ALARMS DEFAULT FFT OPTIONS MACHINE SPEED (RPM) ADD POINT CLEAR ALL POINTS! SAVE AND RETURN ADD NEW CASE : - : 12/03/ :33:30 PLEASE ENTER GROUP NAME? g (DEFINE GROUP) : 12/03/2001 CAP 01:34:20 INS (CAP) Capital (CAP) (Insert or Overwrite) HI INS HI. (Space).(Backspace) (Insert)

10 IVA7008 ESC ENTER (SET MACHINE NAME).. :.(.) (*) (\) (SET ALARMS). =============ALARM SETTINGS============= ALARM 1 SET POINT : 2.80 ALARM 2 SET POINT : 4.10 ALARM TYPE SETTING: NORMAL (VIB.) : 22/03/01 01:36:50 ENT. (ALARM (HI). ESC ENT (Out of Limits) A1 A1 A2 (Within Limits) TYPE SETTING) (Normal (Vib.)). A2 (Alarm Off)

11 IVA7008. ENT.ESC (DEFAULT FFT OPTIONS). ==============FFT OPTIONS============= NUMBER OF LINES: 250 MAX. FREQUENCY : 2000 WINDOW TYPE : HANNING NO. OF AVERAGES: 08 : 23/03/01 12:23:34. ENT VAMOS 40 (NO. OF AVERAGES) ENT. (NO. OF AVERAGES) : (Shaft (MACHINE SPEED (RPM)) / (Numeric) Speed). ADD POINT (CLEAR ALL POINTS!)

12 (ADD POINT) IVA7008 : ==========POINT SPECIFICATIONS========== POINT NAME :1AVEL DESC.: AXIAL DIRECTION VELOCITY ALARM SET FFT OPTIONS SPECIAL SAVE & EXIT 23/03/01 01:23:45 ENT POINT NAME 32 (DESCRIPTION) DESC. ALARM SET.. ALARM SET ( ) (FFT OPTIONS). FFT OPTIONS. SPECIAL. :. ===========POINT SPECIFICATION========== UNIT TYPE : mm/s SHAFT SPEED: /03/01 13:14:50 :

13 IVA7008 mm/s, in/s, mm, mil, m/s2, V, Amp., Pa, kpsi, C, RAD, EU (dynamic), EU (static), m/s2 (Resonance) (1xRPM) SHAFT SPEED ENT. : ESC SAVE &. SAVE & EXIT ESC. EXIT. SAVE & EXIT SAVE AND RETURN... : -.Uploading IVA7008 :.( - ).. Load/Download (WAIT FOR INPUT!) "IVA" Upload.Vamos

14 IVA7008 : Set IVA LOAD/DOWNLOAD.UTILITIES Date/Time Personal Computer IVA7008 ( - ) :DO READING - DO READING ( ) ENERGY UNIT AMMONIA-1 AMMONIA-2 WATER TREATMENT COOLING TOWER GAS PUMPING TURBINES 24/04/01 14:20:54 : ENT (S) (G)

15 IVA7008. (Navigation) AMMONIA-1 TB1200A TB1200B P1100H GB2447T TS2200A TB5700S D4560HG 25/03/01 12:34:34 ENT TB1200A 1AV MOTOR FREE SIDE AXIAL DIR. 1HV MOTOR FREE SIDE HORIZ. DIR. 1VV MOTOR FREE SIDE VERTICAL DIR. 2AV MOTOR COUPLING SIDE AXIAL DIR. 2HV MOTOR COUPLING SIDE HOR. DIR. 2VV MOTOR COUPLING SIDE VERT. DIR. 25/03/01 01:34:36 : ENT. ENT POINT: 1AV DESC.: MOTOR FREE SIDE AXIAL DIR. UNIT: mm/s Alarm1: 2.80 Alarm2: 4.20 POREVIOUS READING: 1.21 CURRENT READING : : PLEASE WAIT.. 25/03/01 10:45:23

16 (Indication bar) (CURRENT) IVA7008 ( ) PLEASE WAIT.. (PREVIOUS). ENT ESC A (Indication bar) (Auto Range ON).. OVR. (Auto Range OFF) " ". OVR : ADC ENT. ESC :PLEASE WAIT NEXT DRAW READ NOTES BACK ENT FFT SPECTRUM, TIME PLOT, READ. PHASE DATA ENTER A 3-DIGIT NOTE CODE? 012 NOTES :

17 MODIFY IVA7008 UTILITIES NOTES.. (A1 OR A2) ALARM2 BACK ALARM1 ALARM2 AUTO (AUTO SIGNATURE ON A2) AUTO SIGNATURE OFF SIGNATURE ALWAYS. : AUTO RANGE ON. : - DRAW : ========SIGNATURE TYPE SELECTION======== FFT SPECTRUM TIME PLOT PHASE DATA 26/03/01 02:23:12

18 (FFT ANALYSIS) TIME PLOT PHASE PLOT IVA RECORD: 01 (No. of Average) : 2.34 Hz (Amplitudes). (Hz). (No. of Averages) (Frequency) (Records) No. of Averages= ( )

19 (Auto IVA7008. Range OFF) (OVR) -. ESC ENT : 2.34 Hz 1000 SAVE SCAN UNIT SCALE SPEED BACK SCAN SAVE (+) (Amplitude) (Shaft Speed).ESC SCAN End. RPM Hz UNIT Home nrpm. ENTER SCALES.

20 IVA7008 ) SPEED. ( ENTER.BACK ESC. :DATA REVIEW -.. (LT) TYPE (LS).NOT COLLECTED! (L) (Alarm Status) (LP) (Phase Data) TB1200A: LEVEL UNIT TIME DATE ST TYP 1AV mm/s 12:34 01/08 OK L 1HV mm/s 12:35 01/08 A1 LS 1VV mm/s 12:39 01/08 OK LT 2AV NOT COLLECTED! 2HV mm/s 12:40 01/08 A2 LS 2VV mm/s 12:43 01/08 A1 LP 25/03/01 01:34:36 ENT. :DOWNLOADING -. WAIT FOR INPUT.. LOAD/DOWNLOAD

21 ESC IVA7008 Terminated...Vamos 3.20

22 IVA7008 : : - :. DO READING UNIT/TYPE mm/s (VEL.) UPPER FREQ.: 1000 LOWER FREQ.: 10 MAX. VALUE : 4.20 (DO RANDOM) 25/03/01 14:06:12 (UNIT/TYPE) (DO READING) (UPPER.ENT (LOWER 50kHz 250 Hz FREQ.:). FREQ.:) None (VDI2056) 10 Hz : DO READING. UNIT: mm/s CURRENT: PLEASE WAIT.. 25/03/01 10:45:10

23 ENT ESC IVA7008. ESC. : FFT ANALYZER - FFT ANALYZER IVA7008. (On-line FFT Analyzer) (No. of Averages=1) 1. ===========FFT ANALYZER MODE============ DO ANALYSIS UNIT TYPE : m/s2 (ACC.) SET OPTIONS LOWER FREQ.: 10 Hz REF. SPEED : /03/01 03:23:09 : DO ANALYSIS PLEASE WAIT.. SAVE. SET OPTIONS UNIT TYPE..DO RANDOM. - : :No. of Lines =

24 IVA7008 :Max. Frequency Hanning :Window function Desigm Min. Error Blackman Hamming and Construction of a System for Vibration Measurement, Analysis and Diagnosis.R.B. Randell No. of Lines=250 Max. Frequency= 1000 Window Type: Hanning No. of Averages= 6 to 8 Frequency Analysis :No.of Averages. : :( ) :( ).( ) LOWER FREQ. ( ) REF. SPEED.None 10 Hz. nrpm

25 IVA IVA7008 : : - IVA7008 : POWER MANAGEMENT KEYBOARD SPEED ALARM ACTIVITY AUTO SIGNATURE AUTO RANGE LEVEL DETECTION UNITS SETTING COMM. OPTIONS OPTIONS 23/03/01 12:23:10 : : - : POWER MANAGEMENT Power off after: 2 Minutes ENT Key Repetition: 12 Times/sec.. (Stroke/sec.). : KEYBOARD SPEED ENT : ALARM ACTIVITY -. ALARM INDICATION: ON OFF :

26 IVA7008 OFF ON.( - ). : - : AUTO SIGNATURE WHEN A2 ALWAYS AUTO SIGNATURE DISABLE AUTO SIGNATURE ALARM2. :AUTO RANGE AUTO RANGE ON AUTO RANGE OFF ENT :.

27 IVA7008 :LEVEL DETECTION mm/s 16 1/16 1/8 1/4 (UPDATED (CONTIUOUS AVERAGING) VALUE). :UNITS SETTING - FREQUENCY IN Hz FREQUENCY IN RPM FREQUENCY IN n.rpm : Hz RPM / n.rpm=(frequency IN RPM SHAFT SPEED) :Communication Options :PICKUP OPTION - (volt/m/s2) (Acceleration pickup) (volt/eu) (µm)

28 IVA7008. (V/µm) : ============= PICKUP OPTIONS============ SET ACTIVE PICKUP SET SENSITIVITIES =============PICKUP SELECTION=========== PICKUP SENS. (V/EU) B&K 4382 ACC T120 TEMP PX-120 disp : 12/04/01 18:20:02 ESC ENTER... : SET SENSITIVITES ========================================= PICKUP1: PICKUP2: PICKUP3: /04/01 18:20:02

29 BATTERY/TEMP. CALIBRATION MEMORY TEST CLEAR DATA CLEAR MEMORY SET DATE/TIME MODIFY NOTES IVA7008 : UTILITIES : 23/04/01 10:21:12 IVA7008 : BATTERY/TEMP. - : BATTERY LEVEL CHECK 0% 50% 99% TEMPRATURE READING: 20 CENT /03/01 08:09:50 50% (Indication Bar) 30%. TMP 55.

30 IVA7008 :CALIBRATION - ADC ZERO TEST ADC F. S. TEST (Calibration) 0 V R54 - (ADC ZERO TEST) UHH-1 (Full-Scale +95 : UHL-30 1, 0, +1. ( - ) Calibration ( - ) PLEASE UHH-1 R55 (ADC F.S. TEST) UHL-30 Reading) +3 VDC +97. : - NO ERROR. Memory Error!! WAIT.. : - CLEAR MEMORY! Are you sure? No Yes. : Yes CLEAR DATA!..

31 IVA7008 :SET DATE/TIME - : PLEASE ENTER TIME AS HH:MM:SS? HH. PLEASE ENTER DATE AS DD-MM-YY? SS MM : YY MM. DD 2000 :MODIFY NOTES -. : 001) High Temperature of lubricant 002) Destroyed mechanical seal 003) Gas escapement (High concentration) 004) Water leak from the seal 005) Bad bearing housing 006) Loose mounting bolts 007) Running over-speed of the machine 26/03/01 01:05:12 ENT. ENT

32 IVA7008 :. : : -. (Electrical Noise). (POWER). : - IPSC-40. Vamos3.20 (POWER).(COMM). COM1 COM2. : - PICKUP SELECTION ( ). : -.

33 IVA7008. :. MEMORY TEST : - MEMORY ERROR!.

34 IVA7008 : : - (Reference (Constant Acceleration. Input)... Exciter) Type of Measurement: Dynamic (EU Peak) Upper frequency=1000 Hz Machine speed <700 RPM Low-pass filter : None Static : : (IVA OPTIONS-PICKUP SELECTION) Do Reading : New sensitivity = (IVA7008 Reading/Reference Input) X Old sensitivity ( ( ( (. :( ). (Accelerometers) UHH-10 4V (Peak) UHH-1 UHL-30 (Peak Value) :( ) 120 mv. ±40 VAC+100 VDC.0.5 Hz

35 IVA7008 : - : Pickup Type Acceleration/ Velocity Displacement Static dynamic (Peak) (RMS) (Pk-Pk) Type 1 (Acc.) From RMS True RMS From RMS 0 Type 2 or 3 True Peak True RMS True Pk-Pk DC component IPSC-40 : - :!!. Supply voltage Supply frequency Supply current Operating temp. Storage temp. Output power Charger Current ITEM MIN MAX TYPICAL UNIT _ _ V Hz Amp. C C W ma :IPSC-40 (D-Size) : - (Ni-Cd) -. BAT. IPSC-40.

36 IVA7008. : Battery/Temp ( ) % % % % % % % % %... :! 7.5. IPSC-40 (100W).

37 IVA7008 ISO10816 :( )

Sentry G3 Machinery Protection Monitor

Sentry G3 Machinery Protection Monitor TECHNICAL INFORMATION Sentry G3 Machinery Protection Monitor CONDITION MONITORING SOLUTIONS The Sentry G3 Machinery Protection Monitor is a high performance signal conditioning unit; providing a universal

More information

Sentry G3 Machinery Protection Monitor

Sentry G3 Machinery Protection Monitor TECHNICAL INFORMATION Sentry G3 Machinery Protection Monitor CONDITION MONITORING SOLUTIONS The Sentry G3 Machinery Protection Monitor is a high performance signal conditioning unit; providing a universal

More information

metro B6012 VIBRATIONS SIMPLIFIED... Product brochure Easiest portable vibration analyzer and balancer TECHNOLOGIES PVT. LTD.

metro B6012 VIBRATIONS SIMPLIFIED... Product brochure Easiest portable vibration analyzer and balancer TECHNOLOGIES PVT. LTD. metro B6012 VIBRATIONS SIMPLIFIED... Product brochure Easiest portable vibration analyzer and balancer TECHNOLOGIES PVT. LTD. Product brocure 1 is reliable, fast and easiest to use tool designed for routine

More information

DTM Distributed Transmitter-Monitor

DTM Distributed Transmitter-Monitor DTM Distributed Transmitter-Monitor DTM10 Proximity Distributed Transmitter-Monitor (Shaft Vibration, Thrust Position and Speed) The DTM10 distributed vibration transmitter-monitor is ideal for monitoring

More information

VM-702B ABSOLUTE VIBRATION MONITOR MODULE Page 1 of 5

VM-702B ABSOLUTE VIBRATION MONITOR MODULE Page 1 of 5 Page 1 of 5 No entry if additional Model Code / Additional Spec. Code ( spec. code is not specified. ) VM-702B /ALY /NB1 /CS1 /CS2 /TRP /TB Analysis Function Non-incendive * 1 Monitor Function Analysis

More information

condition monitoring WP4086 Condition Monitoring System The WP4086 CMS System surveys vibrations with up to 8 external accelerometers

condition monitoring WP4086 Condition Monitoring System The WP4086 CMS System surveys vibrations with up to 8 external accelerometers WP4086 Condition Monitoring System WP4086 Condition Monitor Accelerometer Measuring Points The WP4086 CMS System surveys vibrations with up to 8 external accelerometers Real-time sample, calculation and

More information

WP4086 Condition Monitoring System

WP4086 Condition Monitoring System WP4086 Condition Monitoring System WP4086 Condition Monitor The WP4086 CMS System surveys vibrations with up to 8 external accelerometers Real-time sample, calculation and storage of vibration signals,

More information

Premier Series Monitor

Premier Series Monitor Premier Series Monitor GD000 GAS DETECTOR INSTALLATION AND OPERATION MANUAL IHPN 60600 EAGLE MICROSYSTEMS, INC. 66 Circle of Progress Pottstown, PA 9464 PHONE: 6050 FAX: 6004 copyright /0 Premier Series

More information

VIBRA-series: VIBRA, VIBRA +

VIBRA-series: VIBRA, VIBRA + DATASHEET VIBRA-series (VIB.00100/..120/..130) VIBRA-series: VIBRA, VIBRA + Profound VIBRA-series Vibrations from pile driving, construction, road or rail traffic, demolition work and blasting can create

More information

M7100 Pressure Transducer

M7100 Pressure Transducer SPECIFICATIONS Performance standard on and off highway engine and vehicle OEMs Rugged for heavy equipment and outdoor use Designed specifically for high volume applications Stainless steel wetted surfaces

More information

RPS/DPS High Accuracy Resonant Pressure Sensor. GE Measurement & Control. Features:

RPS/DPS High Accuracy Resonant Pressure Sensor. GE Measurement & Control. Features: GE Measurement & Control RPS/DPS 8100 High Accuracy Resonant Pressure Sensor For over 35 years, Druck has manufactured precision pressure sensors with a capability to meet critical applications in industrial,

More information

Frequently asked questions: Intelligent Transmitter Series

Frequently asked questions: Intelligent Transmitter Series Frequently asked questions: Intelligent Transmitter Series The Wilcoxon family of Intelligent Transmitters, relay alarms, and communication modules can be used to implement low-cost online vibration monitoring

More information

EasyTronic III MANUAL SERVICE

EasyTronic III MANUAL SERVICE rev.6 EasyTronic III MANUAL SERVICE General characteristics: Power supply 24 Vac ±15% Max consumption at 24Vac 300mA Relay outputs 6 Maximum relay current 8 A res. Serial standard RS232 2 Serial standard

More information

RPS/DPS High Accuracy Resonant Pressure Sensor. GE Oil & Gas. Features:

RPS/DPS High Accuracy Resonant Pressure Sensor. GE Oil & Gas. Features: GE Oil & Gas RPS/DPS 8000 High Accuracy Resonant Pressure Sensor Since 1972, Druck has manufactured precision pressure sensors with a capability to meet critical applications in industrial, aerospace,

More information

DGC-500 DIGITAL GENSET CONTROLLER

DGC-500 DIGITAL GENSET CONTROLLER DGC-500 DIGITAL GENSET CONTROLLER Basler Electric s Digital Genset Controller (DGC-500) offers a low cost microprocessor based integrated alternative for the control and monitoring of small to medium sized

More information

CASE HISTORY#1 BAD COOLING TOWER GEARBOX? Barry T. Cease Cease Industrial Consulting (843)

CASE HISTORY#1 BAD COOLING TOWER GEARBOX? Barry T. Cease Cease Industrial Consulting (843) CASE HISTORY#1 BAD COOLING TOWER GEARBOX? Barry T. Cease Cease Industrial Consulting ceasevibration@icloud.com (843) 200-9705 1 CASE HISTORY BAD CT GEARBOX? The customer reported a terrible noise coming

More information

New Sensing products of Meggitt Group. Moscow - October the 23 rd

New Sensing products of Meggitt Group. Moscow - October the 23 rd New Sensing products of Meggitt Group Moscow - October the 23 rd Today s agenda - Who s Meggitt Sensing System - The Measurement division - Sensor production - 2013 released and new incoming products -

More information

DGC-1000 DIGITAL GENSET CONTROLLER

DGC-1000 DIGITAL GENSET CONTROLLER DGC-1000 DIGITAL GENSET CONTROLLER Basler Electric s Digital Genset Controller (DGC-1000) offers a low cost microprocessor based integrated alternative for small to medium sized genset control and monitoring.

More information

Vibration tests on a TNAML Luminaire

Vibration tests on a TNAML Luminaire Sebert Trillingstechniek B.V. Report M13.001-P13.001 rev.01 Date 26 august 2013 Vibration tests on a TNAML Luminaire Client Technor Benelux B.V. Veersteeg 15 4212 LR Spijk The Netherlands Contact Person

More information

CCD-Precision. Intelligent Laser-Optical Displacement Measurement. CCD System. SENSORS & SYSTEMS Authority in Displacement Measurement ILD 1800

CCD-Precision. Intelligent Laser-Optical Displacement Measurement. CCD System. SENSORS & SYSTEMS Authority in Displacement Measurement ILD 1800 SENSORS & SYSTEMS Authority in Displacement Measurement CCD-Precision high accuracy and resolution compact sensor design 5 khz frequency N ILD 1800 TRIANGULATOI PRINCIPLE OPTO NCDT Intelligent Laser-Optical

More information

Ethernet General Purpose

Ethernet General Purpose Ethernet General Purpose Technical Manual Revision 1.03 8 November 2013 Pakton Technologies IO PAE224 Ethernet GPIO Manual.docx Page 1 of 22 Revision 1.03 Last updated 8/11/2013 Table of Contents INTRODUCTION...3

More information

Revision November 2013 JVA Technologies. Ethernet General Purpose IO Technical Manual

Revision November 2013 JVA Technologies. Ethernet General Purpose IO Technical Manual Revision 1.03 8 November 2013 JVA Technologies Ethernet General Purpose IO Technical Manual www.jva-fence.com.au Table of Contents INTRODUCTION...3 Scope and Purpose...3 Glossary...3 SPECIFICATIONS...4

More information

MODEL: 47LPQ. Digital Panel Meters 47 Series. [3] ALARM OUTPUT 0: None 1: N.O. relay contact, 4 points 2: SPDT relay contact, 2 points

MODEL: 47LPQ. Digital Panel Meters 47 Series. [3] ALARM OUTPUT 0: None 1: N.O. relay contact, 4 points 2: SPDT relay contact, 2 points Digital Panel Meters 47 Series PULSE INPUT TOTALIZER (6-digit, LED display type) Functions & Features 6-digit digital panel meter 1/8 DIN size Process integration/totalization with scaling factor adjustment

More information

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers. ModSync Sequencing System Installation & Operation Manual For use with Fulton Steam Boilers. Revision 3.0 8/21/2008 - 2 - Table of Contents Introduction Page 4 Features Page 4 Sequence of Operation Page

More information

CCD-Precision. Intelligent Laser-Optical Displacement Measurement. CCD System SENSORS & SYSTEMS. Authority in Displacement Measurement ILD 1800

CCD-Precision. Intelligent Laser-Optical Displacement Measurement. CCD System SENSORS & SYSTEMS. Authority in Displacement Measurement ILD 1800 SENSORS & SYSTEMS Authority in Displacement Measurement CCD-Precision high accuracy and resolution compact sensor design 5 khz frequency N ILD 1800 TRIANGULATOI PRINCIPLE OPTO NCDT Intelligent Laser-Optical

More information

i-alert Monitoring Solution Sensor App Ai Platform

i-alert Monitoring Solution Sensor App Ai Platform i-alert Monitoring Solution Sensor App Ai Platform Features & Benefits ASSET INTELLIGENCE Monitor the equipment health of any rotating machine such as pumps, motors, fans, and more. EASY TO USE Put machine

More information

RPM1600 Series Room Pressure Monitors

RPM1600 Series Room Pressure Monitors RPM1600 Series Room Pressure Monitors Technical Bulletin LB-RPM1611-0, LB--0 Code No. LIT-12012228 Issued October 2017 Refer to the QuickLIT website for the most up-to-date version of this document. How

More information

DEIF A/S. Description of options. Option M17, Configurable inputs and RPM supervision Engine Controller EC-1/EC-1M. Description of option

DEIF A/S. Description of options. Option M17, Configurable inputs and RPM supervision Engine Controller EC-1/EC-1M. Description of option Description of options Option M17, Configurable inputs and RPM supervision Engine Controller EC-1/EC-1M 4189340401D SW 1.4X.X Description of option Functional description DEIF A/S Parameter list DEIF A/S,

More information

F-1100 Series Single Turbine Meters Suitable for pipe sizes 1 ¼ and larger.

F-1100 Series Single Turbine Meters Suitable for pipe sizes 1 ¼ and larger. ONICON Insertion Turbine Flow Meters Provide an accurate, cost effective option for flow measurement of relatively clean liquids such as those found in closed loop HVAC systems. Each meter is built to

More information

Analog Input Module IC670ALG630

Analog Input Module IC670ALG630 1 IC670ALG630 The Thermocouple (IC670ALG630) accepts 8 independent thermocouple or millivolt inputs. Module features include: Self calibration Two data acquisition rates based on 50 Hz and 60 Hz line frequencies

More information

Company Introduction. Logtech! to aim at best of vibration & noise field

Company Introduction. Logtech! to aim at best of vibration & noise field Company Introduction Logtech! to aim at best of vibration & noise field I. Company overview 1 Introduction History Company Name CEO Foundation Date Main LOGTECH Co., Ltd Yang, Dong-Youk Feb. 2002 - Displacement

More information

Di-440 The Modular Analyser

Di-440 The Modular Analyser Di-440 The Modular Analyser Instrument Concept Single tool for a range of service, maintenance and inspection applications: Condition assessment tool highlights state of machinery today NOT for Predictive

More information

Monitoring Pump Performance with Vibration. Mitchell Stansloski, PhD, PE

Monitoring Pump Performance with Vibration. Mitchell Stansloski, PhD, PE Monitoring Pump Performance with Vibration Mitchell Stansloski, PhD, PE Centrifugal Pumps Centrifugal pumps Centrifugal Pumps (Radial Flow Pumps): A pump using radial flow impellers that give their energy

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS TT-1343 5/06b INSTALLATION INSTRUCTIONS Original Issue Date: 8/03 Model: Automatic Transfer Switches Equipped with Series 1000 Programmable Controller Market: ATS Subject: Remote Annunciator Kits GM28938-KP1,

More information

Advanced Test Equipment Rentals ATEC (2832)

Advanced Test Equipment Rentals ATEC (2832) Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) FEATURES AND SPECIFICATIONS MOLYTEK 2702 AND 3702 RECORDERS 2702 3702 REV: 03302004 Standard Specifications for Model

More information

MODEL: 47LCT. Digital Panel Meters 47 Series. [3] DISPLAY COLOR R: Red YR: Orange G: Green BG: Bluegreen B: Blue W: White

MODEL: 47LCT. Digital Panel Meters 47 Series. [3] DISPLAY COLOR R: Red YR: Orange G: Green BG: Bluegreen B: Blue W: White Digital Panel Meters 47 Series CT DIGITA PANE METER (4½ digit, ED display type, true RMS sensing) Functions & Features 4 ½ digit CT input digital panel meter 1/8 DIN size Moving average function to suppress

More information

Replaced by A5367CA. DISCONTINUED PRODUCT SMOKE DETECTOR WITH INTERCONNECT AND TIMER FEATURES

Replaced by A5367CA. DISCONTINUED PRODUCT SMOKE DETECTOR WITH INTERCONNECT AND TIMER FEATURES Data Sheet 260.8 TIMER START I / O LOW-V SET TIMER OUT + SUPPLY TIMING RES. FEEDBACK 2 3 4 5 6 7 V DD LOGIC OSC. & TIMING DRIVER 8 V SS 9 ABSOLUTE MAXIMUM RATINGS (Voltages are referenced to V SS ) Supply

More information

Wind power Condition Monitoring. Condition Monitoring Systems (CMS) in wind turbines CMS. Authors: Martin Kluge Michael Danitschek

Wind power Condition Monitoring. Condition Monitoring Systems (CMS) in wind turbines CMS. Authors: Martin Kluge Michael Danitschek Systems (CMS) in wind turbines CMS Authors: Martin Kluge Michael Danitschek update: 22.07.2010 page 1 Intelligent vibration monitoring of wind turbines Targets Permanent plant/system protection Reduction

More information

MODEL: 47LT. Digital Panel Meters 47 Series. [3] DISPLAY COLOR R: Red YR: Orange G: Green BG: Bluegreen B: Blue W: White. [4] POWER INPUT AC Power

MODEL: 47LT. Digital Panel Meters 47 Series. [3] DISPLAY COLOR R: Red YR: Orange G: Green BG: Bluegreen B: Blue W: White. [4] POWER INPUT AC Power Digital Panel Meters 47 Series THERMOCOUPLE INPUT DIGITAL PANEL METER (4-digit, LED display type) Functions & Features 4-digit thermocouple input digital panel meter 1/8 DIN size Moving average function

More information

Entero Voice Alarm system. User guide

Entero Voice Alarm system. User guide Entero Voice Alarm system. User guide The manufacturer reserves specification privileges. Information in this manual is subject to change without prior notice or obligation. 2 Table of Contents Introduction...

More information

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA 99336 www.jmcvr.com 1-509-586-9893 Table of Contents TABLE OF FIGURES...1 OVERVIEW OF THE HRC CAPABILITIES...2 INSTALLATION AND

More information

MAJOR CONCERN on your GENERATORS?

MAJOR CONCERN on your GENERATORS? Is STATOR WINDING CONDITION a MAJOR CONCERN on your GENERATORS? Early detection of winding vibration is a key component in preventing forced outages caused by insulation system failures. Our Fiber Optic

More information

Analog Room Pressure Monitor RPC Series

Analog Room Pressure Monitor RPC Series Description The Room Pressure Monitor is used to measure differential pressure in the range of 0.125 to 1"wc or 30 to 250 Pa. It combines precision high sensitivity silicon sensing capabilities and the

More information

Entero Voice Alarm system.

Entero Voice Alarm system. Entero Voice Alarm system. Entero ESC installation menu guide Rev. 1.0 The manufacturer reserves specification privileges. Information in this manual is subject to change without prior notice or obligation.

More information

MF-PFA ver 3.x. Micaflex PFA ver 3. Pressure- and Flow transmitter with alarmfunction. Installation- & Operation manual [Dok. id: mi-303gb_180528]

MF-PFA ver 3.x. Micaflex PFA ver 3. Pressure- and Flow transmitter with alarmfunction. Installation- & Operation manual [Dok. id: mi-303gb_180528] Installation- & Operation manual [Dok. id: mi-303gb_180528] Micaflex PFA ver 3. Pressure- and Flow transmitter with alarmfunction and control output MF-PFA ver 3.x NOTE! Read through the entire manual

More information

Instruction Manual ID-442 Infrared Detector 442-1A Temperature Controller Preamplifier

Instruction Manual ID-442 Infrared Detector 442-1A Temperature Controller Preamplifier 530 Main Street, Acton, MA 01720 Phone: (978)263-3584, Fax: (978)263-5086 Web Site: www.acton-research.com Instruction Manual ID-442 Infrared Detector 442-1A Temperature Controller 442-2 Preamplifier Ver.2.0

More information

Series A3 and A4 Differential Pressure Controller

Series A3 and A4 Differential Pressure Controller Bulletin 102-0 Installation and Operation Series A3 and A4 Differential Pressure Controller Sensocon, Inc. Phone: (863) 248-2800 Fax: (863) 248-2798 www.sensocon.com 1. Introduction 1.1. Model Number Configuration

More information

Application Manual Loop Water Controller

Application Manual Loop Water Controller Application Manual Loop Water Controller AM - LWC TABLE OF CONTENTS LIST OF FIGURES ii iii 1.0 SAFETY CONSIDERATION 1 1.1 Installation Recommendations 1 2.0 GENERAL DESCRIPTION 2 2.1 General Introduction

More information

BSR Addressable Fire Detection control panel. Installation operation manual

BSR Addressable Fire Detection control panel. Installation operation manual BSR-1116 Addressable Fire Detection control panel Installation operation manual ATTENTION!!! READ THE MANUAL BEFORE THE INSTALLATION AND PAY ATTENTION TO PARAGRAPH 2.6.3 AND 2.6.4. Page 2 from 36 Contents

More information

Equipment Required. WaveRunner Zi series Oscilloscope 10:1 High impedance passive probe. 3. Turn off channel 2.

Equipment Required. WaveRunner Zi series Oscilloscope 10:1 High impedance passive probe. 3. Turn off channel 2. FFT Analysis TEN MINUTE TUTORIAL February 27, 2012 Summary Fast Fourier Transform analysis is common on most digital oscilloscopes. It is used to view signals in the frequency as well as the time domain.

More information

ANEMOMETER 4403-RF-BAT

ANEMOMETER 4403-RF-BAT ANEMO 4403 Radio impulsive output Anemometer - Wireless Robust wind speed sensor,extremely resistant and flexible, Suitable for many different application. Stainless steel bearings and high quality technical

More information

MODEL 4300-PG CENTRAL ACCESS PANEL FOR EC-GOLD TRANSMITTERS. User Manual

MODEL 4300-PG CENTRAL ACCESS PANEL FOR EC-GOLD TRANSMITTERS. User Manual MODEL 4300-PG CENTRAL ACCESS PANEL FOR EC-GOLD TRANSMITTERS User Manual Technical Support Continental North America Toll Free 1-(800) 387-9487 Ph: +1 (905) 829-2418 Fx: +1 (905) 829-4701 A Product of Arjay

More information

SENTINEL A - Fault Passage Indicator

SENTINEL A - Fault Passage Indicator SENTINEL A - Fault Passage Indicator AMPEREMETRIC FAULT PASSAGE INDICATORS FOR OVERHEAD MV NETWORKS Installed on poles of overhead lines, the Overhead-Sentinel-A range allows locating the fault arisen

More information

1. Quick start-up guide

1. Quick start-up guide 1. Quick start-up guide This quick guide leads the way to install, start-up and configure necessary parameters in the normal cases. 1. PREPARING INSTALLATION Install fiber optic cable inside conduit. This

More information

DISCONTINUED PRODUCT. For reference only SMOKE DETECTOR WITH INTERCONNECT FEATURES. ABSOLUTE MAXIMUM RATINGS (Voltages are referenced to V SS

DISCONTINUED PRODUCT. For reference only SMOKE DETECTOR WITH INTERCONNECT FEATURES. ABSOLUTE MAXIMUM RATINGS (Voltages are referenced to V SS WITH INTERCONNECT Data Sheet 60.6 NO CONNECT. I / O LOW-V SET NO CONNECT. LED + SUPPLY TIMING RES. FEEDBACK 3 4 5 6 7 NC NC LOGIC OSC. & TIMING DRIVER 0 6 5 4 3 8 V SS GUARD DETECT. IN GUARD SENSITIVITY

More information

Quick Installation Manual LED Touch Keypad Autodial Wireless Alarm System

Quick Installation Manual LED Touch Keypad Autodial Wireless Alarm System Quick Installation Manual LED Touch Keypad Autodial Wireless Alarm System By shield4u http:// (Version 20110816) A. Alarm Understanding Away Disarm Home Emergency Function Signal Interpretation Buzzer

More information

Using the QRAE Plus personal multigas monitor

Using the QRAE Plus personal multigas monitor Using the QRAE Plus personal multigas monitor Firmware v 1.10 QRAE Plus The Hazardous Environment Detection Company QRAE Plus features Turning on the QRAE Plus Recommended Daily Start-up Procedure User

More information

PRODUCT DATA 2260 H, BZ Hand-held FFT System 2260 Investigator and FFT Software BZ7208 Type 2260 H

PRODUCT DATA 2260 H, BZ Hand-held FFT System 2260 Investigator and FFT Software BZ7208 Type 2260 H PRODUCT DATA Hand-held FFT System 2260 Investigator and FFT Software BZ7208 Type 2260 H With FFT Software BZ 7208, 2260 Investigator becomes a single-channel FFT analyzer. It is suitable for measuring

More information

QA16 Addressable System

QA16 Addressable System QA16 Addressable System Operating Manual HORING LIH INDUSTRIAL CO., LTD. www.horinglih.com QA16 System Characteristics Each loop can connect with 250 devices. Easy system programming through PC to panel.

More information

EAGLE 2000B EAGLE 2000BE EAGLE 2000EBT MUST READ MANUAL PRIOR TO INSTALLING MACHINE

EAGLE 2000B EAGLE 2000BE EAGLE 2000EBT MUST READ MANUAL PRIOR TO INSTALLING MACHINE EAGLE 2000B EAGLE 2000BE EAGLE 2000EBT MUST READ MANUAL PRIOR TO INSTALLING MACHINE Contents 1 Machine Safety Information 3 1.5 Safety Precautions Prior to Operating Machine 6 2 Machine Installation 7

More information

DI220 Using the Optional Docking Station The maintenance and operating functions of the Micro IV can be automated with the Micro IV Docking Station.

DI220 Using the Optional Docking Station The maintenance and operating functions of the Micro IV can be automated with the Micro IV Docking Station. DI220 Using the Optional Docking Station The maintenance and operating functions of the Micro IV can be automated with the Micro IV Docking Station. The following steps outline the correct sequence to

More information

More Precision. indusensor // Linear inductive displacement sensors

More Precision. indusensor // Linear inductive displacement sensors More Precision indusensor // Linear inductive displacement sensors 4 Gauges with external controller indusensor LVDT - Proven LVDT technology - Measuring ranges ±1 ±10mm - Excellent price/performance ratio,

More information

VAP304 PRO INSTALLATION & OPERATION MANUAL

VAP304 PRO INSTALLATION & OPERATION MANUAL VAP304 PRO INSTALLATION & OPERATION MANUAL Panic Fire Duress Program Bypass Report Chime Test Memory B A D C Program Chime Panic Duress Exit Fire Report Bypass Memory Test Reset Password Exit Reset Password

More information

OPERATION MANUAL MODEL & ACCELEROMETER

OPERATION MANUAL MODEL & ACCELEROMETER OPERATION MANUAL MODEL 8011-01 & 8021-01 ACCELEROMETER TE CONNECTIVITY SENSORS///MODEL 8011-01 & 8021-01 ACCELEROMETER 05/2016 Page 1 WARRANTY Measurement Specialties, Inc. accelerometers are warranted

More information

INSTRUCTION MANUAL and DETAILED PRODUCT SPECIFICATION TRIPLEX PUMP CONTROL SYSTEM MODEL NUMBER CPC-3. M336 Rev F. November 21, 2000.

INSTRUCTION MANUAL and DETAILED PRODUCT SPECIFICATION TRIPLEX PUMP CONTROL SYSTEM MODEL NUMBER CPC-3. M336 Rev F. November 21, 2000. INSTRUCTION MANUAL and DETAILED PRODUCT SPECIFICATION TRIPLEX PUMP CONTROL SYSTEM MODEL NUMBER CPC-3 M336 Rev F November 21, 2000 ÇConsilium Consilium US, Inc. 59 Porter Rd Littleton, MA 01460-1431 USA

More information

Pioneer-R16 Gas Monitor Operator s Manual

Pioneer-R16 Gas Monitor Operator s Manual Pioneer-R16 Gas Monitor Operator s Manual Edition 7/2/97 RKI INSTRUMENTS, INC RKI Instruments, Inc. 33248 Central Ave, Union City, CA 94587 (510) 441-5656 Chapter 1: Description About the Pioneer-R16 Gas

More information

More Precision. indusensor Linear inductive displacement sensors

More Precision. indusensor Linear inductive displacement sensors More Precision. indusensor Linear inductive displacement sensors - 1 - Standard sensors 4 LVDT series - gauges with external controller Proven LVDT technology Measuring ranges ±1 ±10mm Excellent price/performance

More information

Technical Manual Ionisation Chamber MUSIC80

Technical Manual Ionisation Chamber MUSIC80 Technical Manual Ionisation Chamber MUSIC80 Entwicklungsbüro Dr. R. Schneider Lärchenstraße 9 85640 Putzbrunn Tel: 089 608 533 71 Fax: 089 608 533 72 E-Mail: robert@schneider.net Entwicklungsbüro Andreas

More information

SPECIFICATION FOR APPROVAL

SPECIFICATION FOR APPROVAL SPECIFICATION FOR APPROVAL Customer : STD Description : DC FAN Customer Part No. REV. : Delta Model No. : REV. : 01 Sample Issue No. : Sample Issue Date : AUG.14 2017 PLEASE SEND ONE COPY OF THIS SPECIFICAITON

More information

EasyLog Data Logger Series

EasyLog Data Logger Series EasyLog Data Logger Series Overview EasyLog model EL-USB series products are a line of low cost, compact, battery-operated data loggers with built-in memory and USB interface. Each product in the line

More information

SENTINEL D - Fault Passage Monitoring

SENTINEL D - Fault Passage Monitoring SENTINEL D - Fault Passage Monitoring DIRECTIONAL FAULT PASSAGE INDICATORS FOR OVERHEAD MV NETWORKS Installed on poles of overhead lines, the Overhead-Sentinel-D range allows locating the fault arisen

More information

More Precision. indusensor // Linear inductive displacement sensors

More Precision. indusensor // Linear inductive displacement sensors More Precision indusensor // inear inductive displacement sensors 6 Displacement sensors with external electronics indusensor VDT - Proven VDT technology - Measuring ranges ±1 ±25mm - Extremely accurate

More information

CN-6000 Series. Features. Ordering information CN C1. Part descriptions. 5 ( key: Used to enter parameter set mode, move to parameters,

CN-6000 Series. Features. Ordering information CN C1. Part descriptions. 5 ( key: Used to enter parameter set mode, move to parameters, CN-6000 eries Features Multi-input CN-610 : Thermocouple 12 types, RTD 5 types, Analog (mv, V, ma) 6 types CN-640 : 0 to 50.00kHz Improves visibility with negative LCD : 12 segment, 3 colors (selectable

More information

31.05/ Unit-1

31.05/ Unit-1 Semi-Annual Inspection FS Report 31.05/02.06.2015 Unit-1 Customer Representative: GE Field Service Representative: All technical recommendations and information contained in this report are based on GE

More information

Mark 25 Ultrapure Water Conductivity Analyzer

Mark 25 Ultrapure Water Conductivity Analyzer Martek Instruments, Inc. Mark 25 Ultrapure Water Conductivity Analyzer Instruction Manual WARRANTY POLICY Unless otherwise stated, MARTEK INSTRUMENTS, INC. warrants this equipment to be free from defects

More information

Compact Sensor Heads for In-situ and Non-Contact Standoff Gas Sensing using TDLAS in Harsh Environments

Compact Sensor Heads for In-situ and Non-Contact Standoff Gas Sensing using TDLAS in Harsh Environments VG07-018 Compact Sensor Heads for In-situ and Non-Contact Standoff Gas Sensing using TDLAS in Harsh Environments Mickey B. Frish, Richard T. Wainner, Matt C. Laderer Physical Sciences Inc. Andover, MA

More information

DSGH. Radiation-Based Detector with GEN2000 Electronics for Density Measurement QUICK REFERENCE GUIDE

DSGH. Radiation-Based Detector with GEN2000 Electronics for Density Measurement QUICK REFERENCE GUIDE DSGH Radiation-Based Detector with GEN2000 Electronics for Density Measurement QUICK REFERENCE GUIDE Revision History Revision History Version of manual Description Date 1.0 Initial release 051025 1.1

More information

CN-6000 Series. Features. Ordering information CN C1. Part descriptions. 5 ( key: Used to enter parameter set mode, move to parameters,

CN-6000 Series. Features. Ordering information CN C1. Part descriptions. 5 ( key: Used to enter parameter set mode, move to parameters, CN-6000 eries Features Multi-input CN-610 : Thermocouple 12 types, RTD 5 types, Analog (mv, V, ma) 6 types CN-640 : 0 to 50.00 khz Improves visibility with negative LCD : 12 segment, 3 colors (selectable

More information

Laser Particle Sensor Module PM2009

Laser Particle Sensor Module PM2009 Laser Particle Sensor Module PM2009 Application Air purifier, air quality monitor Ventilation system, air conditioner with purifying function Auxiliary product of consumer electronic products Environmental

More information

CASE STUDY ANALYSIS OF CENTRIFUGAL FAN HIGH AMPLITUDE VIBRATION. Ken Singleton

CASE STUDY ANALYSIS OF CENTRIFUGAL FAN HIGH AMPLITUDE VIBRATION. Ken Singleton CASE STUDY ANALYSIS OF CENTRIFUGAL FAN HIGH AMPLITUDE VIBRATION Ken Singleton Manager KSC Consulting LLC, Bristol VA ksingleton@vibrationconsulting.com Bob McGinnis. P.E. McGinnis Engineering LLC, Kingsport

More information

INSTALLATIONN GUIDE & OPERATION MANUAL

INSTALLATIONN GUIDE & OPERATION MANUAL INSTALLATION INSTRUCTIONS ECO # 1569 REVISION #0006 FCS SERIES MODEL 5025, 5045,7525 & 7545 INSTALLATION INSTRUCTIONS BY: DATE: 01/23/2013 INSTALLATIONN GUIDE & OPERATION MANUAL MOTOR OPERATOR (V3.02 Controls)

More information

VAV Thermostat Controller Specification and Installation Instructions. Model TRO24T4XYZ1

VAV Thermostat Controller Specification and Installation Instructions. Model TRO24T4XYZ1 Model TRO24T4XYZ1 Description The TRO24T4XYZ1 is a combination controller and thermostat. The VAV Thermostat Controller is designed for simple and accurate control of any variable air volume box in a number

More information

Condition Monitoring Report. Customer.

Condition Monitoring Report. Customer. vibration - thermography - oil analysis - laser alignment - in-situ balancing Unit 12, Roseberry Court, Ellerbeck Way, Stokesley, North Yorkshire, TS9 5QT. tel: 01642 714710 website: www.vibrotech.co.uk

More information

LOUP II DRILL MONITOR OPERATION MANUAL. SOFTWARE v45

LOUP II DRILL MONITOR OPERATION MANUAL. SOFTWARE v45 LOUP II DRILL MONITOR OPERATION MANUAL SOFTWARE v45 Service and Technical Support Contact: Loup Electronics Inc. Address: 2960 N. 38th Street Lincoln, NE 68504 Phone: 877-489-LOUP(5687) 402-464-7131 Fax:

More information

Vitalmax 4000 CL Product Specifications

Vitalmax 4000 CL Product Specifications Page 1 of 5 Vitalmax 4000 CL 510 Garden Avenue North, Clearwater, FL 33755 Phone: (727) 442-8118 Fax: (727) 443-7257 A. Mechanical Description Size 10" H x 13" W x 8"D (25 cm x 33 cm x 20 cm) Weight 18

More information

ENERGY LIGHT USER S GUIDE ENERGY LIGHT USER S GUIDE

ENERGY LIGHT USER S GUIDE ENERGY LIGHT USER S GUIDE ENERGY LIGHT USER S GUIDE Release January 2001 CONTENTS 1.0 GENERAL CHARACTERISTICS... 4 1.1 MAIN CHARACTERIS TICS... 4 2.0 USER INTERFACE (CODE C5121230)... 5 2.1 DISPLAY... 5 2.2 MEANING OF THE LEDS...

More information

Tachometer/Hourmeter/Trip. Installation and Operation Manual

Tachometer/Hourmeter/Trip. Installation and Operation Manual 3211 Fruitland Ave Los Angeles, CA 90058 MTH-103E Tachometer/Hourmeter/Trip Installation and Operation Manual Rev. G P/N 145F-13048 PCO - 00010525 Copyright 2014-2017, Barksdale Inc. All Rights Reserved

More information

General Purpose IO Technical Manual

General Purpose IO Technical Manual General Purpose IO Technical Manual Revision 1.06 8 November 2013 Pakton Technologies PAE222 GPIO Manual.docx Page 1 of 21 Revision 1.06 Last updated 8/11/2013 Table of Contents INTRODUCTION...3 Scope

More information

More Precision. indusensor // Linear inductive displacement sensors

More Precision. indusensor // Linear inductive displacement sensors More Precision indusensor // Linear inductive displacement sensors 4 Gauges with external controller indusensor LVDT - Proven LVDT technology - Measuring ranges ±1 ±10mm - Excellent price/performance ratio,

More information

WIO200 Water In Oil measuring instrument

WIO200 Water In Oil measuring instrument WIO200 Water In Oil measuring instrument You have made the right decision by choosing a measuring instrument from PAJ Systemteknik. Many customers buy our high standard products every year. There are at

More information

Event Monitoring Device (EMD)

Event Monitoring Device (EMD) Event Monitoring Device (EMD) DRK-S701 INSTALLATION AND OPERATION MANUAL VERSION 2.2 - NOVEMBER 2015 PART NUMBER DRAM-BOOK DO NOT DISCARD! Contents Description Page Introduction/Features 2 Controls and

More information

DIGITAL PANEL METER N20Z TYPE

DIGITAL PANEL METER N20Z TYPE DIGITAL PANEL METER N20Z TYPE USER S MANUAL 1 Contents 1. APPLICATION and METER DESIGN... 5 2. METER SET... 5 3. BASIC REQUIREMENTS, OPERATIONAL SAFETY... 6 4. INSTALLATION... 7 5. SERVICE... 9 6. ERROR

More information

Model Super TJE. Ultra Precision Pressure Transducer DESCRIPTION FEATURES

Model Super TJE. Ultra Precision Pressure Transducer DESCRIPTION FEATURES Ultra Precision Transducer DESCRIPTION Model Super TJE is one of the most accurate industrial pressure transducers available today. The Super TJE features 0.05 % accuracy and zero temperature error of

More information

Leuze electronic. Dimensioned drawing. Electrical connection. Accessories: 150m ISO 9001

Leuze electronic. Dimensioned drawing. Electrical connection. Accessories: 150m ISO 9001 Throughbeam photoelectric sensors Dimensioned drawing 15m 1-3 V DC A 2 LS Throughbeam photoelectric sensors with high performance reserve in infrared light Robust metal housing with glass cover, protection

More information

PowerWizard. Level 1.0 & Level 2.0 Control Systems Training

PowerWizard. Level 1.0 & Level 2.0 Control Systems Training PowerWizard Level 1.0 & Level 2.0 Control Systems Training New Systems Current Systems Systems Comparison Level 1 Level 2 Level 3 Level 4 PowerWizard Level 3.0 PowerWizard Level 4.0 Overview Common parts

More information

CONTROL PANEL INTERFACE ACTIVATE THE GENERATOR DISPLAY INTERFACE MENUS. Control Panel USING THE AUTO/OFF/MANUAL SWITCH

CONTROL PANEL INTERFACE ACTIVATE THE GENERATOR DISPLAY INTERFACE MENUS. Control Panel USING THE AUTO/OFF/MANUAL SWITCH CONTROL PANEL INTERFACE USING THE AUTO/OFF/MANUAL SWITCH With the switch set to AUTO, the engine may crank and start at any time without warning. Such automatic starting occurs when utility power source

More information

1 Appendix - Product Specifications

1 Appendix - Product Specifications 1 Appendix - Product Specifications WARNING The patient monitor may not meet its performance specification if stored or used outside the manufacturer s specified temperature and humidity range. 1.1 Safety

More information

Specification , July 2015

Specification , July 2015 Technical Information PrecisionLine Controllers EDC21 / EDC22 / EDC23 EASYSET DIGITAL CONTROLLERS Specification 51-52-3-48, July 215 Introduction The EDC21, EDC22 and EDC23 controllers provide precise

More information

ZLM4 OEM Technical Manual

ZLM4 OEM Technical Manual ZLM4 OEM Technical Manual Version 3, June 2014 JVA Technologies Pty Ltd Page 1 of 32 Issue:1/08/2014 10:49:00 AM Contents INTRODUCTION... 4 Scope and Purpose... 4 DRAFT... 4 Features... 5 Limitations...

More information

TV2 Room Pressure Monitor Quick Start Guide

TV2 Room Pressure Monitor Quick Start Guide TV2 Room Pressure Monitor Quick Start Guide 1. The Care and Use guide for your TV2 Room Pressure Monitor can be downloaded here: www.e2di.com/usersguides.html Please print out the Users Guide. Although

More information