FS-100 Series OUTLINE MAIN APPLICATIONS FEATURES LEVEL SWITCH
|
|
- Eugenia Emma Mason
- 5 years ago
- Views:
Transcription
1 PERFECT ISOLATION BY MAGNET COUPLING COVERING HIGH TEMP., HIGH PRESS., AND VACUUM APPLICATIONS PRESSURE TIGHT FLAMEPROOF FOR HYDROGEN ATMOSPHERE READY SPRING BALANCED DISPLACER TYPE FS- Series LEVEL SWITCH OUTLINE FS- is a spring balanced displacer type level switch. The pressurized part and electric part are perfectly isolated by magnet coupling system to offer much more safety and durability compared to other mechanical sealing types. FS- can meet tough application with high temperature and high pressure. FEATURES Wide selection range for temperature and pressure. Variety of material selection for displacer, spring and chambers for suitable anticorrosive capability. Perfect isolation between pressurized part and electric compartment by magnetic coupling for high reliability and safety. In addition to watertight construction, pressure tight and intrinsically safe versions are ready to meet hazardous application. Especially, pressure tight flameproof suitable for Hydrogen atmospher (Ex diic T) is available which eliminates the necessity of safety barriers. MAIN APPLICATIONS Fuel oil tank level control Process control for petrochemical plants Water treatment plants Oil rig's platform Other liquid level control
2 FS- DISPLACER, LEVEL SWITCH STANDARD SPECIFICATION Detection theory Measuring object Density Viscosity : By spring balanced displacer : All types of liquids (Liquid level or liquid interface) : For level detection.5 g/cm or more For liquid interface detection* Difference of. g/cm or more *Number of points for alarm: point : Max. mpa s. Liquid without sticking, crystallization, or freezing Accuracy : ± (Density. g/cm ) (For level detection with water (AMB, ATM)) Repeatability : ±5 (Density. g/cm ) (For level detection with water (AMB, ATM)) Reset span : Max. (Density.g/cm ) Exceeds depending on switch types, density and number of alarm points. Pressure range : Full vacuum to.9 MPa Temp. Range : to + C (Upto -9 C on request. Consult factory for details.) Enclosure : Watertight IP5 Equ. FS- W Pressure tight flameproof Ex d IIC T FS- EX Intrinsically safe EX ia IIC T FS- S Amb. Temp. : to +8 C to +55 C for pressure tight flameproof to + C for Intrinsically safe versions Type of process connection and flange sizes : : Standard : Optionally available : Not available Tank top, welding Internal chamber type Standard Material: (Refer to MODEL for special material availability) Liquid wetting part Displacer SUS, SUS, SUSL Spring SUS Rod SUS Wire SUS Chamber Carbon steel, SUS, SUS, SUSL Vapor contacting part Lead pipe SUS, SUS Top flange Carbon steel, SUS, SUS SUSL Non-contacting part Electric housing Aluminum die-casting Alarm contact :,, or points Limitation based on switch type and temperature range are applicable, Refer to MODEL for further details. Type of contact Contact capacity Cable entry: : Standard SPDT Microswitch Options SPDT (Equ. to DPDT action) Hermetical sealed Microswitch : Refer to Model Model Classification Cable entry Remarks FS- W Watertight G/ FS- EX Ex d IIC T G/ Cable dia. ø9 to G/ Cable dia. ø to FS- S Ex ia IIC T G/ NPT thread etc. are applicable with adapter. Size Density <.8 g/cm Density.8 g/cm 8 (") (") 5 (5") 5 (") Tank top, insertion internal chamber type Size Density <.8 g/cm Density.8 g/cm 8 (") (") 5 (5") 5 (") Tank side, external chamber type Size Density <.8 g/cm Density.8 g/cm 8 (") (") 5 (5") 5 (") Terminal Painting Colour : FS- W, E X, S : Up to 5 C - M.5 screw Over 5 C - M screw : For liquid temp. upto 5 C Polyurethan resin painting For liquid temp. more than 5 C Silicone resin painting : Silver (standard) INSTRUCTION FOR USE The FS level switch with a spring operates in response to changes in the buoyancy of the displacer. Because alarms are set at a given operating density and temperature, if the density or temperature changes, the alarm level may shift or the alarm may not be issued. Do not use this switch in tanks with a mixer or other similar apparatus. TOKYO KEISO CO., LTD. TG-L7-E
3 FS- DISPLACER, LEVEL SWITCH ALARM POINT The following figure shows alarm points that can be set under conditions of room temperature, atmospheric pressure, and a liquid equivalent to water. The alarm points depend on the design. INTRINSICALLY SAFE RELAY (EBC) Intrinsically safe relay is to be inserted into the contact loop of FS- S type level switch. to points use relays are available. Select suitable IS relay considering the total number of contacts. Standard specification Min.5 Min.5 Min. 5 Explosion protection Rated operating voltage Rated operating current Installation location Contact configuration Relay output (Resistance load) Contact allowable power (Resistance load) Insulation resistance Withstand voltage Intrinsically safe Ex ia IIC V DC ±% ma DC ±% Non-hazardous area a contact 5 V AC, A V DC, A 75 VA AC 7 W DC 5 DC V at MΩ 5 V AC ( min.) For point alarm For points alarm (H or L) (H-H, H-L or L-L) Model code Description EBC- Output type R R Model Relay output No. of contact Power supply A D point use points use points use V to V AC, 5/ Hz V DC Min.5 Min.55 EBC-R EBC-R, R Min. 5 Min. 5 Min Min. 5 Min. () terminal MIN.ø MAX. MAX. MIN.5. For points alarm For points alarm Terminal screw size : M (H-H-L or H-L-L) (H-H-L-L) EBC Dimensions CAUTIONS FOR PIPING In case of the frameproof type (FS- EX) and intrinsically safe type (FS- S) to be used in Japan, the cable wiring is to be conducted in accordance with the enforcement regulations of "Cable Wiring" system in FLAMEPROOF TYPE CABLE WIRING as specified in "Industrial Safety and Health Law". For details, refer to "USER'S GUIDELINES for Electrical Installation for Explosive Gas Atmospheres in General Industry" edited by MINISTRY OF HEALTH, LABOUR AND WELFARE RESERCH INSTITUTE OF INDUSTRIAL SAFETY JAPAN. FS- EX type pressure tight flameproof version is certified for Ex d II C T classification under the condition of using our designated pressure tight cable glands which are delivered together with level switches. They are to be properly installed. TG-L7-E TOKYO KEISO CO., LTD.
4 FS- DISPLACER, LEVEL SWITCH MODEL SWITCH TYPE, TEMP, CLASS C O DE A B C D E F G H I J K L M N LIQUID TEMP ( C) ON/OFF MECHANISM TYPE CONTACT TYPE SWITCH MODEL SWITCH SUPPLER CONTACT CAPACITY 5~5 VX-5-A 5~ V5-AT SPDT ~8 GENERAL T-GV 8~ PURPOSE OMRON 5~5 VX-5-A 5~ V5-AT SPDT ~8 EARTHQUAKE PROOF T-GV 8~ (G) TYPE 5~5 5~8 8~5 SPDT SM 5~5 SPDT SSMA 5~ HERMETIC (GOLD PLATED) SEAL Azbil 5~5 TYPE 5~8 8~5 SPDT SM 5~5 SPDT 5~ (GOLD PLATED) SSMA 5~5 VX-5-A SPDT 5~ EARTHQUAKE V5-AT PROOF 5~5 (G) TYPE VX-5-A SPDT 5~ V5-AT OMRON SPECIAL AC5V, 5A DC5V,.A AC5V, A DC5V,.A AC5V, 5A DC5V,.A AC5V, A DC5V,.A AC5V, 5A DC5V,.A DCV, 5A AC5V,.A DCV,.A AC5V, 5A DC5V,.A DCV, 5A AC5V,.A DCV,.A AC5V, 5A DC5V,.A NO. OF COOLING FIN *: For applications with lower temperature than C, an extension unit will be added and the external dimension will be different from the standard versions. Consult factory for details. *: Applicable alarm of interface detection is point. *: C or less are points. PRESSURE RATING PRESSURE RATING K(5#) Class K(#) Class K(#) Class HIGH PRESS. APPLICATION MINIMUM APPLICABLE LOAD MAX POSSIBLE ALARM ONTACT * * ENCLOSURE W EX S L Switch Type, Enclousure FS- ENCLOSURE WATERTIGHT (IP5EQU.) PRESSURE TIGHT EX-PROOF (Ex d IIC T) INTRINSICALLY SAFE EX-PROOF (Ex ia IIC T) NUMBERS OF ALARM Refer to MODEL. NUMBER OF ALARM POINT POINTS POINTS POINTS LEAD PIPE MATERIAL LEAD PIPE MATERIAL SUS SUS 7 DISPLACER MATERIAL DISPLACER MATERIAL SUS (Standard) SUS SUSL 5 TOP FLANGE MATERIAL S L TOP FLANGE MATERIAL CARBON STEEL SUS SUS SUSL 8 SPRING MATERIAL SPRING MATERIAL SUS (Up to C) * * Available special material UNS N7 (Equ. to HASTELLOY C), INCONEL (INCONEL is selected for applications more than C temperature.) TOKYO KEISO CO., LTD. TG-L7-E
5 FS- DISPLACER, LEVEL SWITCH Alarm Contact Material Connection Chanber UPPER GASKET MATERIAL UPPER GASKET MATERIAL CUSTOMER'S SCOPE (CHAMBER NOT PROVIDED) VORTEX GASKET (SUS) VORTEX GASKET (SUS) Bolts, nuts and gaskets for process connection are to be supplied by the customer. EXTERNAL CHAMBER CONNECTION EXTERNAL CHAMBER CONNECTION CHAMBER NOT PROVIDED "SW Rc "FLANGE 9 TOP FLANGE SIE TOP FLANGE SIE 8(") (") 5 5(5") 5(") CAMBER MATERIAL CHAMBER MATERIAL CHAMBER NOT PROVIDED S Carbon steel SUS SUS L SUSL TOP FLANGE SIE RATING 5 TOP FLANGE SIE RATING JISKFF JISKRF JPI#5 ANSI#5 JISKRF JPI# ANSI# CHAMBER CONSTRUTION CHAMBER CONTRUTION NOT PROVIDED INTERNAL, WELDING TYPE(FIG.A) INTERNAL, INSERSION TYPE(FIG.B) EXTERNAL, SIDE~SIDE (FIG.C) EXTERNAL, SIDE~BOTTOM (FIG.D) TG-L7-E TOKYO KEISO CO., LTD. 5
6 FS- DISPLACER, LEVEL SWITCH DIMENSIONS. DETECTING PART FS-W FS-W FS-W FS-W G/ 7 G/ 7 G/ 77 FS-EX FS-EX FS-EX FS-EX MAX.7 MAX.7 MAX.7 7 MAX G/ 77 TOKYO KEISO CO., LTD. TG-L7-E
7 FS- DISPLACER, LEVEL SWITCH. CHAMBERS Internal, welding type Fig.A Internal, Insersion type Fig.B " flange " flange L: Min.5 L : Min. L: Min.5 L : Min. External, Side to Side Fig.C External, Side to Bottom Fig.D L L 5 (standard) L: Min. L : Min. L L: Min. L : Min.5 L L L L " Alarm level Alarm level " flange " flange 5 (standard) Alarm level Alarm level L. DISPLACER A standard displacer for detecting the level of liquid equivalent to water at normal temperature (ρ =. g/cm ). Dimension may differ for lower density liquid, interface detection and liquid temperature. TG-L7-E TOKYO KEISO CO., LTD. 7
8 FS- DISPLACER, LEVEL SWITCH ORDERING INFORMATION ALARM POINT, SETTING, INSTRUCTION TAG NO. MODEL Q'TY LIQUID NAME DENSITY FS Please notify the follow for order / inquiry : For liquid level detection Gas: Liquid: For two liquids interface detection Upper: Lower: For liquid level detection Gas: Liquid: For two liquids interface detection Upper: Lower: (Difference of at least. g/cm required. Only point for alarm.) PRESS. TEMP Nor. Nor. Max. Max. MPa C ( ( ) ) point alarm points alarm points alarm points alarm h h High Low h h h High Low h High Low h High h High Low Limitation of alarm setting point is applicable due to technical reason. Refer to Page for details. Not required Internal welding type Internal insertion type External, Side to Side External, Side to Bottom h h h h Low h h h h High h High h Low h Low CHAMBER h : : : : OTHER SPECIAL FEATURES AND INSTRUCTION * Specification is subject to change without notice. Head Office : Shiba Toho Building, 7 Shibakoen, Minato-ku, Tokyo Tel : +8-5 (KEY) ; Fax : overseas.sales@tokyokeiso.co.jp ; URL : 8 TG-L7-E
Metal Tube Variable- Area Flow Meter (Series KM, KMS, KMSS)
MAXIFLO TM Overview MaxiFlo TM KM Series Metal Tube Rotameters are rugged, versatile and accurate variable area (VA) flow meter offering 2.0% full scale accuracy. It s based on simple and easy-to-understand
More informationEnraf Servo Gauge 854 XTG
Enraf Servo Gauge 854 XTG Cut costs, not repeatability. Honeywell s 854 XTG servo gauge is a high performance alternative to other tank level measurement technologies such as radar tank level gauges. It
More informationGeneral Specifications
General Specifications Model DM8 Vibration Type Liquid Density Meter Overview In 1967, YOKOGAWA developed the Model VD6 Vibration Type Liquid Density Meter in response to user requests for an online density
More informationPressure-Resistant and Explosion-Proof Electric Contact Pressure Gauges and Pressure Switches
CATALOG No. 3150 MODEL No. AdC No. AdS Pressure-Resistant and Explosion-Proof Electric Contact Pressure Gauges and Pressure Switches AdC-Type Pressure Gauges with Contact AdC-WType Differential Pressure
More informationLevel gauges Series LS Level indicator, switch and transmitter for liquids
Level gauges Series LS Level indicator, switch and transmitter for liquids Simple construction Resistant under extreme temperature and pressure conditions No risk of leakage Measuring range: from 150 mm
More informationAnalog Transmitter AT1000 AT1
Technical Information Analog Transmitter AT1000 AT1 Alarm Transmitter for Mechanical Level Gauges Application AT1 analog transmitter is designed to be installed to the LT, and LTC series float level gauge.
More informationVERSAFLOW VORTEX Supplementary instructions
VERSAFLOW VORTEX Supplementary instructions Vortex flowmeter Equipment category II 2G CONTENTS VERSAFLOW VORTEX 1 Safety instructions 3 1.1 General notes... 3 1.2 EC conformity... 3 1.3 Approval according
More informationEnraf Servo Gauge 854 ATG
Enraf Servo Gauge 854 ATG Setting the standard in gauging. From the company that pioneered development of modern tank gauges, Honeywell s 854 Automatic Tank Gauge has become an industry standard all over
More informationBrooks MT3600 Series Metal Tube Variable Area Flowmeters
Data Sheet Flanged, NPT or socket-welded connections 10% full scale accuracy Disassembly for cleaning without removal from the process line Standard direct reading, detachable scales Permanent magnetic
More informationBristol Babcock Oil Content Monitor "oil in water"
NORTHEAST CONTROLS INC. ONLINE www.nciweb.net 123 Pleasant Avenue - Upper Saddle River - New Jersey 07458 USA Tel: 201-327-7660 / Fax: 201-327-3242 Bristol Babcock Oil Content Monitor "oil in water" General
More informationUser s Manual YTA610 and YTA710 NEPSI Certification
User s Manual YTA60 and YTA70 NEPSI Certification [Option code: /NS, /NS5 and /NF] st Edition . INTRODUCTION Thank you for purchasing the YTA60 and YTA70 Temperature transmitters. This manual contains
More informationUltrasonic Switches. Features & Benefits
Why use an ultrasonic switch over other level technologies? Depending upon your application, there may be three or four technologies equally suited for your application; however; only one will be the best
More informationRosemount 2090P Pulp and Paper Pressure Transmitter
Product Data Sheet Rosemount 2090P Pulp and Paper Pressure Transmitter Rosemount 2090P 1-inch flush mount compatible with a PMC process connection, or 1 1 /2-inch threaded mounting connection Absolute
More informationUltrasonic Point Level Switches
see more at SORInc.com Request Quote Ultrasonic Point Level Switches Ultrasonic point level switches are a cost-effective solution for your applications. Installation requires mounting the sensor (threaded
More informationDräger Polytron 5100 EC Detection of toxic gases and vapors
Dräger Polytron 5100 EC Detection of toxic gases and vapors The Dräger Polytron 5100 EC is a cost-effective explosion proof transmitter for the detection of toxic gases or oxygen. It uses a high performance
More information1510 Side Mounted Level Switch
1510 Side Mounted Level Switch General Instructions The SOR 1510 Level Switch mounts into the side of a vessel. Electric switching action is provided by the float moving a magnet into the field of a hermetically
More informationOPTIBAR DP 7060 Supplementary Instructions
OPTIBAR DP 7060 Supplementary Instructions Differential pressure transmitter Category ATEX II 1/2G, 2G Ex db ia IIC T6...T1 Ga/Gb, Gb IECEx Ex db ia IIC T6...T1 Ga/Gb, Gb Housing Aluminium: Single chamber,
More informationSurvey of electrical equipment installed in hazardous areas on tankers
(June 2015) Survey of electrical equipment installed in hazardous areas on tankers 1. Application The recommendations in this document apply for survey of electrical installation in hazardous areas on
More informationAnnubar Flowmeter Series
Reference Manual Appendix B Approvals Annubar Flowmeter Series Hazardous Locations Installations.................. page B-1 Rosemount 3051SFA Product Certifications.......... page B-1 Rosemount 3095MFA
More informationImmersion heaters for ATEX/IECEx hazardous areas or in non-atex version
for ATEX/IECEx hazardous areas or in non-atex version * Non contractual picture Warning It is imperative to read these instructions carefully before installing or maintaining the equipment. MI100EN 09/2017
More informationSanitary Pressure Transmitter
Product Data Sheet 00813-0100-4698 Sanitary Pressure Transmitter A TRADITION OF EXCELLENCE IN PERFORMANCE Absolute or gage pressure ranges from 0 3 to 0 800 psi 0.20% reference accuracy, including linearity,
More informationMSM400 Ultrasonic Suspended Solids Monitoring and Control System
Product Data Sheet MSM400 Ultrasonic Suspended Solids Monitoring and Control System Continuous sludge discharge monitor for up to 50% suspended solid The MSM400 system contains a control unit and either
More informationNORTH AMERICAN ADVANCED TECHNOLOGIES, INC.
NORTH AMERICAN ADVANCED TECHNOLOGIES, INC. WSS-W Core-extractable protective bimetal thermometer (Adjustable angle, Back, Bottom Connected) WSSX-W Gear style core-extractable protective bimetal thermometer
More informationDust Concentration Meter
Dust Concentration Meter To Sense Breaks or Tears in Filter Bags, to Improve Product Quality, and to Eliminate related Environmental and Safety Risks Triboelectric Dust Monitor Particles in the air are
More informationL+T GASETECHNIK. Klöpper-Waldmann GmbH & Co. K G. Alarm unit LSG4
Areas of application The LSG4 alarm unit is used for monitoring industrial systems, e.g. in the following areas: Alarm and hazard stati in production e.g. for monitoring temperature and pressure in reactors
More informationTank Gauge Transmitter AT-5000
Technical Information TI 0 N/08/en/0.05 AT-5000 Tank gauge transmitter for level limit and alarm contact transmission Introduction The AT-5000 series of transmitters are used for transmitting level limit
More informationManual Power relay SR853
Manual Power relay SR853 Product types SR853.8.x.x, Rev. 1 SR853 manual page2 The symbols WARNING, CAUTION, NOTE This symbol warns of a serious hazard. Failure to observe this warning may result in death
More informationDräger Polytron 5100 EC Detection of toxic gases and vapors
Dräger Polytron 5100 EC Detection of toxic gases and vapors The Dräger Polytron 5100 EC is a cost-effective explosion proof transmitter for the detection of toxic gases or oxygen It uses a high performance
More informationOfficine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0
Officine Meccaniche M.A.M. Apparecchiature Antideflagranti DOCUMENT IS-EJB-A-14 rev. 0 Instructions Flameproof enclosures EJB../W series for command, control, signaling and/or automation Emission date:
More informationM-Switch Float Operated Liquid Level Switch
Product Data Sheet M-Switch Float Operated Liquid Level Switch Reliably detects the liquid level to give a voltage free contact operation for alarm signalling or as part of a pump control system Small
More informationInstrumentation and Controls Group
Instrumentation and Controls Group Jerguson Gage and Valve is the leading supplier of level gaging products, offering the world s largest selection of liquid level gage glasses, magnetic gages, and accessories.
More informationAbsolute and Gage Pressure Transmitter
Product Data Sheet 0083-000-4699 Absolute and Gage Pressure Transmitter ATRADITION OF EXCELLENCE IN THE PULP AND PAPER INDUSTRY Mounts flush to process media -inch flush mount compatible with a PMC process
More informationINSTRUCTION MANUAL FLOAT TYPE LEVEL SWITCHES HITROL CO., LTD.
HITROL CO., LTD. HEAD OFFICE.FACTORY.R&D INSTITUDE HITROL CO., LTD 141, Palhakgol-road, Jori-eup Paju-si, Gyeonggi-do, Korea TEL. : (00)-82-31-950-9700 FAX. : (00)-82-31-943-5600 www.hitrol.com INSTRUCTION
More informationOil Leak Detector NAR300 System
Technical Information Oil Leak Detector NAR300 System Equipped with two detection principles: Conductivity and vibration sensor Application This system is set up in a pit, dike or plant, or sump pit near
More informationInstruction Manual September 2010 SITRANS LVL200S
Instruction Manual September 2010 SITRANS LVL200S Contents Contents 1 About this document 1.1 Function.................................. 4 1.2 Target group.............................. 4 1.3 Symbolism
More informationDuct heaters for ATEX/IECEx hazardous areas or in non-atex version
for ATEX/IECEx hazardous areas or in non-atex version * Non contractual picture Warning It is imperative to read these instructions carefully before installing or maintaining the equipment. MI200EN 09/2017
More informationAzbil introduction 2015
Azbil introduction 2015 Overview Azbil introduction & company profile Product divisions Product overview Magnetic flow meter (MTG) Magnetic flow meter (MGG) Thermal mass flow meters Pressure transmitter
More informationATEX. Tough controls for tough environments. ia.danfoss.com. Brochure Controls. Danfoss controls - designed and approved for hazardous areas
Brochure Controls Tough controls for tough environments Danfoss controls - designed and approved for hazardous areas ATEX approved program ia.danfoss.com Danfoss controls tailored for use in hazardous
More informationAdditional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.
Additional Operating Instructions SITRANS F Vortex flowmeters Ex-d Edition 09/208 CONTENTS Safety instructions 3. General notes... 3.2 EU conformity... 3.3 Approval according to the IECEx scheme... 3.4
More informationIntrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20
Electronic Pressure Measurement Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20 Applications Chemical, Petrochemical
More informationPressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications
Force Pressure Temperature Switch Pressure sensors Ex ia I / IIC T6 acc. to ATEX with internal diaphragm with front flush diaphragm Accuracy: 0,25% and 0,5 % Standard output: 4...20 ma; 2-wire system Description
More informationModel 144H. Product Data Sheet , Rev DB February Content
Rosemount 144 PC-Programmable Temperature Transmitter Provides an installation-ready solution for temperature monitoring applications using Complete Point Solutions (CPS) Increases measurement accuracy
More informationCirculation heaters for ATEX/IECEx hazardous areas or in non-atex version
for ATEX/IECEx hazardous areas or in non-atex version * Non contractual picture Warning It is imperative to read these instructions carefully before installing or maintaining the equipment. MI500EN 09/2017
More informationRFM Series RFM-ISR Barrier. Installation Manual
PSM INSTRUMENTATION LTD RFM Series RFM-ISR Barrier Installation Manual Issue A Burrell Road Industrial Estate Haywards Heath, West Sussex RH16 1TW, UK Tel: +44 (0)1444 410040 Fax: +44 (0)1444 410121 Http://www.psm-sensors.co.uk
More informationREGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC
EUROPEAN ATEX DIRECTIVE > European Directive 2014/34/EU ATEX Directive 2014/34/EU is a "new approach" directive that applies to protective systems against explosions as well as all equipment used in or
More informationRosemount 2088 Absolute and Gage Pressure Transmitter
Product Data Sheet Rosemount 2088 Rosemount 2088 Absolute and Gage Pressure Transmitter Absolute and gage pressure ranges from 0 1.5 psi to 0 4,000 psi (0 0.1 to 0 276 bar) Performance of 0.075% with high
More informationAdditional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.
Additional Operating Instructions SITRANS F Vortex flowmeters Ex-i Edition 09/2018 CONTENTS 1 Safety instructions 3 1.1 General notes... 3 1.2 EU conformity... 3 1.3 Approval according to the IECEx scheme...
More informationINSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres
INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres 1) Introduction The BExBG05D-SIL is a flameproof beacon which is certified
More informationInductive slot sensor
0102 Model Number Features 2 mm slot width Technical Data specifications Switching function Normally closed (NC) Output type NAMUR Slot width 2 mm Depth of immersion (lateral) 5... 7 mm, typ. 6 mm Output
More informationLimit Switch Box YT-870/875 SERIES
Limit Switch Box YT-870/875 SERIES PRODUCT MANUAL VERSION 1.01 Contents 1. Introduction 3 1.1 General information for the users. 3 1.2 Manufacturer Warranty 3 1.3 Explosion Proof Warning. 3 2. Product
More informationEJBX. Ex d. AISI 316L stainless steel. - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67
Ex d EJBX AISI 316L stainless steel - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67 Quartz sand blasting Warning labels Mounting bracket Silicone gasket
More informationInstallation Guide. EXGP Oxygen Analyzer System (ATEX) Interface Electronics Unit
EXGP Oxygen Analyzer System (ATEX) Installation Guide Interface Electronics Unit DO NOT OPEN WHEN ENERGISED OR WHEN AN EXPLOSIVE GAS ABB The Company We are an established world force in the design and
More informationINSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS FAW, FAW-C & FAW-C-T TYPE AIR WARMERS FCR & FCR-A TYPE CONVECTORS
INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS FAW, FAW-C & FAW-C-T TYPE AIR WARMERS FCR & FCR-A TYPE CONVECTORS STW & STW-T SAFE AREA AIR WARMERS HFT, AFT & SAT TYPE AIR THERMOSTATS Please read these
More informationOPTIWAVE X500 Supplementary Instructions
OPTIWAVE X500 Supplementary Instructions OPTIWAVE 3500 C OPTIWAVE 6500 C OPTIWAVE 7500 C Supplementary Instructions for ATEX applications KROHNE CONTENTS OPTIWAVE X500 1 General safety information 4 1.1
More informationDräger Polytron 8100 EC Detection of toxic gases and vapors
Dräger Polytron 8100 EC Detection of toxic gases and vapors The Polytron 8100 EC is Dräger s top of the line explosion proof transmitter for the detection of toxic gases or oxygen It uses a high performance
More informationVibrating level switch for solids Diamond Point
Vibrating level switch for solids Diamond Point erande nivåvakter. varedelen att vibrera. mpas Tough and reliable vibrating level switch for bulk solids. High versatility: applicable for many materials:
More informationOil Leak Detector NAR300 System High Temperature
Technical Information Oil Leak Detector NAR300 System High Temperature Application This system is set up in a pit, dike or plant, or sump pit near the pump yard, where it provides the ultimate leak detection
More informationUser s Manual. AXF Series Magnetic Flowmeter Installation Manual ATEX and IECEx Explosion Proof Type IM 01E20A01-11EN IM 01E20A01-11EN.
User s Manual AXF Series Magnetic Flowmeter Installation Manual ATEX and IECEx Explosion Proof Type Contents 1. ATEX Documentation 2. Explosion Proof Type Instrument 2.1 ATEX...2 2.2 IECEx...7 1 2 Integral
More informationProcess Instrumentation. Product Guide. Registered Quality System to ISO 9001
Process Instrumentation Product Guide Registered Quality System to ISO 9001 SORis committed to and understands the demanding requirements of the process industry. We design, develop and manufacture the
More informationExplosion-proof Immersion Heater Type D-8660
Explosion-proof Immersion Heater Type D-8660 Sinus Jevi has developed explosionproof Ex de heating equipment, for hazardous area. The flame-proof (d) enclosures have been designed for non save areas to
More informationDräger Polytron 5700 IR Detection of flammable gases and vapours
Dräger Polytron 5700 IR Detection of flammable gases and vapours The Dräger Polytron 5700 IR is a cost effective explosion-proof transmitter for the detection of flammable gases in the lower explosive
More informationUsing the Model 1500 Portable Chilled Mirror Hygrometer
APPLICATION NOTE 2016_0120 MODEL 1500 Rev C Using the Model 1500 Portable Chilled Mirror Hygrometer The Model 1500 is a portable, multi-function, optical chilled mirror hygrometer designed to accurately
More informationOilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor
Labkotec UK Ltd Adminicle House 1 Lumb Lane Audenshaw Manchester M34 5WH GREAT BRITAIN Tel: 0844 3350 477 Fax: 0161 4281 179 E-mail: info@labkotec.co.uk 10.8.2012 Internet: www.labkotec.co.uk 1/13 OilSET-1000
More informationIntrinsic Safety Solenoid Valves :-
Intrinsic Safety Solenoid Valves :- Intrinsic safety valves can be used for applications that require similar explosion class/ignition degree to d2g4 or Exd II BT5 type (explosion-proof enclosure construction).
More informationCirculation Heaters Selection Guidelines
Selection Guidelines Selecting a Circulation Heater Application Factors Corrosion Policy Selecting the proper circulation heater component requires critical engineering judgement and careful evaluation
More informationRosemount 2090F Hygienic Pressure Transmitter
Hygienic Pressure Transmitter Conforms to 3-A Sanitary s Features CIP/SIP service for process temperatures up to 284 F (140 C) Absolute or gage pressure ranges from 0-1.5 to 0-300 psi Mounts with either
More informationDruck DPI 705/DPI 705 IS Series
GE Sensing & Inspection Technologies 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Druck DPI 705/DPI 705 IS Series Digital Pressure
More informationMODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL
TRACON MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL TABLE OF CONTENTS FPT 130 Overview... 2 Installation... 3 Power Source and Load Connections... 4 Temperature Sensor... 5 External
More informationBINDER Scientific Product Catalog
BINDER Scientific Product Catalog 36 Vacuum drying ovens Vacuum drying ovens 37 VD VDL VDL EX-Zone 2 Absolutely reliable drying Drying with no residues, no danger of incrustation, no oxidation all under
More information120W Hazardous Location LED Fixture V DC - Modbus TCP/IP - Network Controlled - Dimmable
120W Hazardous Location LED Fixture - 12-24V DC - Modbus TCP/IP - Network Controlled - Dimmable Part #: HAL-ANC-60-120W-ITG-LED-DIMM-1224 Page: 1 The Larson Electronics HAL-ANC-60-120W-ITG-LED-DIMM-1224
More informationDB5 Intrinsically Safe Sounder Type DB-5
Operating Instructions RTK Instruments Limited DB5 Intrinsically Safe Sounder Type DB-5 Description The DB5 Sounder is a strong, lightweight warning sounder, CENELEC certified to Ex II 1G EExia IIC T4
More informationDräger Polytron 8100 EC Detection of toxic gases and oxygen
Dräger Polytron 8100 EC Detection of toxic gases and oxygen The Polytron 8100 EC is Dräger s top of the line explosion-proof transmitter for the detection of toxic gases or oxygen It uses a high performance
More informationCirculation Heaters Selection Guidelines
Selection Guidelines Selecting a Circulation Heater Application Factors Corrosion Policy Selecting the proper circulation heater component requires critical engineering judgement and careful evaluation
More informationRTK Instruments Limited St James Business Park, Knaresborough, North Yorkshire, England. HG5 8PJ
Operating Instructions RTK Instruments Limited Telephone: 44 (0)1423 580500 Facsimile: 44 (0)1423 580501 DA135 Intrinsically Safe LED Beacon Introduction This manual provides the information necessary
More informationModel 144H. Product Data Sheet , Rev DB February Content
Rosemount 144 PC-Programmable Temperature Transmitter Provides an installation-ready solution for temperature monitoring applications using Complete Point Solutions (CPS) Increases measurement accuracy
More informationPYROS. Código: FT-PY01-I Revisión: TECHNICAL DATA. Polycarbonate tube of 4 mm. thickness LIGHT FITTING. Laquered steel painted white
. TECHNICAL DATA LIGHT FITTING REFLECTOR Polycarbonate tube of 4 mm. thickness Laquered steel painted white END CAPS Aluminium 2030 (polyester paint RAL 7047) POWER SOURCE LAMP TYPE 220-240V, 50/60Hz T8
More informationRTK Instruments Limited St James Business Park, Knaresborough, North Yorkshire, England. HG5 8PJ
Operating Instructions RTK Instruments Limited PEX7250 Explosion Proof Annunciator Introduction This manual provides the information necessary to install, connect, test and maintain the PEX7250 Explosion
More informationE2S Datasheet v10a. The IS-mA1 is suitable for all intrinsically safe signalling applications including fire, security and process control.
E2S Datasheet 1.2.1 v10a ISmA1 ISminialarm The ISmA1 is a compact, 100dB(A) alarm sounder. Approvals include ATEX, IECEx and GOSTR for Zone 0 applications and FM approval for Class I Division 1 and Class
More informationSPECIFICATION SHEET ORGANIC POLLUTION MONITOR. Model: OPM-410A - Organic Pollution Monitor - Issue: OPM-410A-0107-R0 Page 1 ISO ISO-9001
ISO-14001 ISO-9001 SPECIFICATION SHEET ORGANIC POLLUTION MONITOR Model: OPM-410A The Model OPM-410A monitors organic pollution in water from industrial effluent, rivers etc.. The design and construction
More informationTechnical Specification of High and Low Temperature Altitude Test Chamber
Technical Specification of High and Low Temperature Altitude Test Chamber Model: KU-504L Manufacturer: KOMEG Technology Ind Co.,Ltd 1 / 8 Ⅰ. Control methods and characteristics No:16081010 Edition:00 High
More informationINSTRUCTION MANUAL (ATEX / IECEx)
INSTRUCTION MANUAL (ATEX / IECEx) BExS110D and BExS110D-R Sounder For use in Flammable Gas and Dust Atmospheres BExS110D BExS110D-R 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT
More informationFlange immersion heaters
Flange immersion heaters for ATEX/IECEx hazardous areas or in non-atex version HEATING GASES HEATING LIQUIDS MAINTAINING A CONTINUOUS TEMPERATURE CETAL flange immersion heaters are designed and manufactured
More informationSensall Sapphire. Thermo MeasureTech ULTRASONIC POINT LEVEL SYSTEM
ULTRASONIC POINT LEVEL SYSTEM Introduction Compliance with growing government regulations mandates tighter level controls with advanced diagnostics to avoid releases, overspills and costly environmental
More informationYTA Series Temperature Transmitters [Style: S3] EN :2006, -11:2007, -26:2007. Supply circuit: Ui=30 V, Ii=165 ma,
User s Manual YTA Series Temperature Transmitters [Style: S3] Manual Change No. 10-008 Please use the attached sheets in the following manuals when the product is with /KU2 option and EN60000 Series based
More informationDräger Polytron 5200 CAT Detection of flammable gases and vapours
Dräger Polytron 5200 CAT Detection of flammable gases and vapours The Dräger Polytron 5200 CAT is a cost-effective explosion-proof transmitter for the detection of flammable gases in the lower explosion
More informationScrew plug immersion heaters
Screw plug HEATING GASES HEATING LIQUIDS MAINTAINING A CONTINUOUS TEMPERATURE The screw plug by CETAL are designed and manufactured as a standard range or according to customer specifications. Reliability
More informationIntrinsically Safe, NEMA 4, Type 4X, IP67 Loop-Powered Meter
PD685 Intrinsically Safe, NEMA 4, Type 4X, IP67 Loop-Powered Meter Actual Size Digits C US Intrinsically Safe 3½ Digits LARGE DISPLAY NEMA 4, Type 4X, IP67 Loop-Powered Field-Mount Process Meter 4-20 ma
More informationApproved by: Document no.: EGT
ET Page 1 of 6 TECHNICL MNUL EXPLOSION PROOF MNUL CLL POINT / PUSH BUTTON TEX Marking: Code: II 2D EPL b, Db Ex d IIC T6 IP66 Ex tb IIIC T85 C Marking details: Please note that every care has been taken
More informationSERIES 46000E Bi-Directional In-Line Deflagration Flame Arrester
SERIES 46000E Bi-Directional In-Line Deflagration Flame Arrester Suitable for use with Explosion Group IIB3 or IIA (NEC Groups C or D) Vapors PROTECTOSEAL CAUTION: If any questions arise concerning the
More informationINSTALLATION, OPERATION
OM No. E-SCSF-170111-1 INSTALLATION, OPERATION and MAINTENANCE MANUAL Thermodynamic Steam Trap MODEL: SC/SF MIYAWAKI INC. Osaka, Japan 2 SAFETY INSTRUCTION Prior to using the SC/SF steam trap, read this
More informationINSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS EXHEAT FLR TYPE FLAMEPROOF RADIATORS
INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS EXHEAT FLR TYPE FLAMEPROOF RADIATORS Please read these instructions thoroughly before installation and ensure they are passed on to the end-user 1 1.0
More informationAdditional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.
Additional Operating Instructions SITRANS F Vortex flowmeters Ex-nA Edition 08/207 CONTENTS Safety instructions 3. General notes... 3.2 EU conformity... 3.3 Approval according to the IECEx scheme... 3.4
More informationUsing the DewTrak II Dew Point/ Humidity Transmitter
APPLICATION NOTE 2016_FEB2 DT Rev 10 Using the DewTrak II Dew Point/ Humidity Transmitter The Model DewTrak ll Dew Point/Humidity Transmitter is a compact, cost effective, optical chilled mirror hygrometer.
More informationMetal Tube Variable Area Flowmeter with Optional Electronics based on Smart Meter Manager Technology
Data Sheet Brooks Model MT 3810 Metal Tube Variable Area Flowmeter with Optional Electronics based on Smart Meter Manager Technology GENERAL FEATURES Broad range of flow capacities 5% Full scale accuracy
More informationAEU1. Explosion-Proof Electric Air Heater For Hazardous Locations
AEU1 Explosion-Proof Electric Air Heater For Hazardous Locations 0518 II 2G, Ex d IIB T4 Gb IP55 (ATEX) Ex d IIB T4 Gb IP55 (IECEx) 1ExdIIBT4 X IP55 (EAC Ex) (Suitable for ATEX/IECEx/EAC Ex Zone 1 & 2)
More informationRosemount 3051 Pressure Transmitter
Quick Start Guide 00825-0100-4001, rev. JA Rosemount 3051 Pressure Transmitter with 4-20 ma HART and 1-5 Vdc Low Power Protocol Rosemount 3051CF Series Flowmeter Transmitter with 4-20 ma HART and 1-5 Vdc
More informationDräger Polytron 5720 IR Toxic Gas Detection
Dräger Polytron 5720 IR Toxic Gas Detection The Dräger Polytron 5720 IR is a cost-effective explosion proof transmitter for the detection of carbon dioxide in volume percentage or ppm It uses a high-performance
More informationVIBRATION TRANSMITTER MODEL 140T INSTALLATION The mounting orientation can be in any position. This position should be in an area for the best vibrati
VIBRATION TRANSMITTER MODEL 140T A lowcost, yet highly accurate and rugged vibration transmitter, the Model 140T is ideal for use with all machines, even those which previously may have been considered
More informationSapphire ULTRASONIC POINT LEVEL SYSTEM
ULTRASONIC POINT LEVEL SYSTEM Introduction Compliance with growing government regulations mandates tighter level controls with advanced diagnostics to avoid releases, overspills and costly environmental
More informationGeneral Specifications
General Specifications Model GD402 Gas Density Meter Overview The Model GD402 gas density analyzer and Model GD40 detector not only provide continuous measurement of gas density, but also several other
More information