1 DE-06 Plain Edge Protector Seal Options used with/without s Range FD60 Product Range FD60 Intumescent & Smoke seal (brush seal) DE-04 with Intumescent Seal DE-05 with Intumescent & Smoke Seal (twin fin) Intumescent & Smoke seal (elastomeric fin) DE-05 with Intumescent & Smoke Seal (brush) Intumescent seal
2 Latched or Unlatched Single acting single doorset ( & overpanel) Double acting single doorset (& overpanel) Latched or Unlatched Single acting double doorset (& overpanel) Double acting double doorset (& overpanel) Doorset Configurations FD60 Doorset Configuration - FD60
3 Colour Options Standard Colours Snow White Eggshell Taupe Mocha French Cream Grey Cloud Pearl Grey Charcoal Pacific Blue Storm Dusty Jade Mint Turquoise Please Read Door Edge Protection FD60 Non-Standard Colours 933 Mission White 24 Dove 14 Mimosa 16 Harvest Gold 17 Sherbet 2012 Salmon 663 Violet 520 Imperial Purple 11 Alpine Blue 12 Cobalt 10 Mint Green 129 Yale Blue 967 Hunter Green 193 Gingerspice 966 Burgundy 108 Black 845 Spectrum Red 111 Wedgewood Blue CS Acrovyn Edge Protectors have been tested and assessed to BS 476 Part achieving in excess of 30 minutes (DE-01, DE-02 and DE-03) and 60 minutes (DE-04, DE-05 and DE-06) fire resistance when tested as part of timber based fire door assemblies. Chiltern test reports RF11059, RF11061 and Chiltern assessments ChiltA11129, ChiltA11130 refer. Where smoke seals are incorporated into the Acrovyn Edge Protectors in order for the door assemblies to provide cold smoke control, the smoke seal elements have been independently tested to BS 476 Part 31.1 and have achieved leakage rates not exceeding 3m³/m/hr when tested at 25 Pa. CS Acrovyn Edge Protectors are not designed or intended to upgrade non fire rated door assemblies to fire resisting assemblies but are designed and tested for use with fire door assemblies of proven fire resistance to current BS and EN test methods. The buyer takes responsibility for determining suitability and compliance with relevant mandatory requirements. recommend that where any doubt exists, expert opinion is sought.
4 Latches and Locks Door Edge Gaps Head Seals 1 x C/S Intumescent seal and 1 x C/S Intumescent & Smoke seal must be fitted 5mm each side of the centreline within frame reveal. Fixings Door Frame Protection Door frames may have the jambs partially or fully clad with 2mm thick Acrovyn which must be bonded to the frame using 3M Scotch/grip cement 10 contact adhesive, or equivalent. Frame Seals 1 x C/S Intumescent seal and 1 x C/S Intumescent & Smoke seal must be fitted 5mm each side of the centreline within frame reveal. Door Leaf Construction Graduated density or laminated particleboard, Laminated softwood or hardwood strip core with timber based facings, Timber based stiles and rails with flaxboard or particleboard cores and timber based facings. Timber based stiles and rails with timber, flaxboard or particleboard cores, non-combustible sub-facings and timber based external facings Glazing within constructions is permitted. Hardware Protection 1mm thick intumescent paper under : - Hinge blades, - Encasing latch bodies, - Latch forends, - Latch keeps, - Flush bolts No lippings required. Hinges Door Frame Construction Optional Door Leaf Protection Door leaves with Acrovyn Protection must be bonded to the doors using 3M Scotch/grip cement 10 contact adhesive, or equivalent. Flush Bolts Flush bolts meeting the following criteria are acceptable:
5 FD60 Single Door Leafs FD60 Double Door Leafs Door Leaf Dimensions FD60 Door Leaf Dimesions - FD60
Regulatory Reform (Fire Safety) Order 2005
Regulatory Reform (Fire Safety) Order 2005 This document has been prepared by ASDMA (Architectural & Specialist Door Manufacturers Association) to provide for guidance for Responsible Persons in respect
More informationSection 2 - Applications - General. Section 2A - FD30 Strebord 35+, 38+, 44 & Superpan with MDF & Wood Frames
Section 2 - Applications - General Section 2A - FD30 Strebord 35+, 38+, 44 & Superpan with MDF & Wood Frames Section 2B - FD30 Strebord 35+, 38+, 44, Superpan & Strebord 54 with Steel Frames Section 2C
More informationSpecification, installation & maintenance of fire doors: Technical Note 2
Specification, installation & maintenance of fire doors: Technical Note 2 March 2016 You & Your Care \\raptor\user data\users\kbyard www.bdct.nhs.uk Karen Byard: Fire Officer Tel: 07946 413 331 Karen.byard@bdct.nhs.uk
More informationCERTIFICATE OF APPROVAL No CF 5542 ASSA ABLOY SECURITY SOLUTIONS
CERTIFICATE OF APPROVAL No CF 5542 This is to certify that, in accordance with TS00 General Requirements for Certification of Fire Protection Products The undermentioned products of 11B Street, Jebel Ali
More informationStrebord 35 FD30 Strebord 44 FD30 Strebord 54 FD60
.1 Strebord 35 FD30 Strebord 44 FD30 Strebord 54 FD60 Falcon Panel Products Ltd Clock House Station Approach Shepperton Middlesex TW17 8AN Strebord Technical Manual (Version 9.1) Validation of Data against
More informationThe Fire Resistance Performance Of Timber Or Mineral Composite Based Insulated Doorsets When Fitted With D & E Architectural Hardware Spring Hinges
Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 (0) 1925 655 116 F : +44 (0) 1925 655 419 E : warrington@exova.com W: www.exova.com Title: The Fire Resistance Performance
More informationCERTIFICATE OF APPROVAL No CF 5038 FREEMAN & PARDOE T/A ARROW ARCHITECTURAL
CERTIFICATE OF APPROVAL No CF 5038 1 This is to certify that, in accordance with TS00 General Requirements for Certification of Fire Protection Products The undermentioned products of Tything Road, Arden
More informationCERTIFICATE OF APPROVAL No CF 391 UNION ARCHITECTURAL HARDWARE
CERTIFICATE OF APPROVAL No CF 391 1 This is to certify that, in accordance with TS00 General Requirements for Certification of Fire Protection Products The undermentioned products of School Street, Willenhall,
More informationCERTIFICATE OF APPROVAL No CF 530 HOPPE (UK) LIMITED
CERTIFICATE OF APPROVAL No CF 530 This is to certify that, in accordance with TS00 General Requirements for Certification of Fire Protection Products The undermentioned products of Gailey Park Industrial
More information25 th November Title:
Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 (0) 1925 655 116 F : +44 (0) 1925 655 419 E : warrington@exova.com W: www.exova.com Title: The Fire Resistance Performance
More informationFire Protection. Intumescent fire and smoke seals for door assemblies
Fire Protection Intumescent fire and smoke seals for door assemblies Intumescent Seals Fire Protection Quality you can trust Exitex offer a wide range of fully tested intumescent strips, glazing seals
More informationCERTIFICATE OF APPROVAL No CF 145 GEZE UK LIMITED
CERTIFICATE OF APPROVAL No CF 145 This is to certify that, in accordance with TS00 General Requirements for Certification of Fire Protection Products The undermentioned products of Blenheim Way, Fradley
More informationCERTIFICATE OF APPROVAL No CF 5494 ASSA ABLOY AB
CERTIFICATE OF APPROVAL No CF 5494 1 This is to certify that, in accordance with TS00 General Requirements for Certification of Fire Protection Products The undermentioned products of Klarabergsviadukten
More informationCERTIFICATE OF APPROVAL No CF 114 EXIDOR LIMITED
CERTIFICATE OF APPROVAL No CF 114 1 This is to certify that, in accordance with TS00 General Requirements for Certification of Fire Protection Products The undermentioned products of Progress Drive, Cannock,
More informationProduct. Regulations. Agrément Certificate No 92/2841 Third issue* Designated by Government to issue European Technical Approvals
Lorient Polyproducts Ltd Fairfax Road Heathfield Industrial Estate Newton Abbot Devon TQ12 6UD Tel: 01626 834252 Fax: 01626 833166 e-mail: admin@lorientuk.com website: www.lorientgroup.com CI/SfB (32.5)
More informationFire doors guidance. Provided by
Fire doors guidance Provided by Contents 1. Scope... 3 2. Introduction... 3 3. Where you could find a fire door... 4 4. Doors not required to be fire doors... 5 5. Which way should a fire door open?...
More informationCERTIFICATE OF APPROVAL No CF 252 GEZE UK LIMITED
CERTIFICATE OF APPROVAL No CF 252 This is to certify that, in accordance with TS00 General Requirements for Certification of Fire Protection Products The undermentioned products of Blenheim Way, Fradley
More informationCERTIFICATE OF APPROVAL No CF 5263 KCC ARCHITECTURAL
CERTIFICATE OF APPROVAL No CF 5263 This is to certify that, in accordance with TS00 General Requirements for Certification of Fire Protection Products The undermentioned products of Unit 1 Westgate Business
More informationCERTIFICATE OF APPROVAL No CF 5657 UNION ARCHITECTURAL HARDWARE
CERTIFICATE OF APPROVAL No CF 5657 1 This is to certify that, in accordance with TS00 General Requirements for Certification of Fire Protection Products The undermentioned products of School Street, Willenhall,
More informationfire doors the burning issues From specification to maintenance the life cycle of a fire door explained guide
fire doors the burning issues From specification to maintenance the life cycle of a fire door explained guide Passive Fire Protection Passive fire protection products are built into the fabric of a building,
More informationA Guide to the Selection of Smoke Seals for Doorsets. Information Sheet No. 5. Intumescent Fire Seals Association
Information Sheet No. 5 Intumescent Fire Seals Association A Guide to the Selection of Smoke Seals for Doorsets THE HOME OF REACTIVE PROTECTION SYSTEMS CONTENTS Page Introduction 1 Purpose of smoke seals
More informationCl/SfB (32.5) Xt7 (K2) Acoustic, Smoke and Fire Seals for Door Assemblies
Cl/SfB (32.5) Xt7 (K2) Acoustic, Smoke and Fire Seals for Door Assemblies protecting against sound, smoke and fire Fire and smoke protection measures are essential, lifesaving precautions in a building.
More informationCERTIFICATE OF APPROVAL No CF 118 DORMA UK LTD
CERTIFICATE OF APPROVAL No CF 118 1 This is to certify that, in accordance with TS00 General Requirements for Certification of Fire Protection Products The undermentioned products of Wilbury Way, Hitchin,
More informationCERTIFICATE OF APPROVAL No CF 5075 EXIDOR LIMITED
CERTIFICATE OF APPROVAL No CF 5075 This is to certify that, in accordance with TS00 General Requirements for Certification of Fire Protection Products The undermentioned products of Progress Drive, Cannock,
More informationPractice Guidee No.1. of the
Intumescent Fire Seals Association Good Practice Guide No. 1 The Fire Risk Assessors Good Practice Guidee No.1 Guidance to risk assessors in respect of the use of intumescent door sealss THE HOME OF REACTIVE
More informationCERTIFICATE OF APPROVAL No CF 530 HOPPE (UK) LIMITED
CERTIFICATE OF APPROVAL No CF 530 1 This is to certify that, in accordance with TS00 General Requirements for Certification of Fire Protection Products The undermentioned products of Gailey Park Industrial
More informationTitle: The Air Leakage Performance of Timber Doorsets fitted with NOR710 Smoke Seals in Accordance with BS 476: Part 31, Section 31.
Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 (0) 1925 655 116 F : +44 (0) 1925 655 419 E : warrington@exova.com W: www.exova.com Title: The Air Leakage Performance of
More informationCERTIFICATE OF APPROVAL No CF 738 ALLEGION (UK) LIMITED
CERTIFICATE OF APPROVAL No CF 738 This is to certify that, in accordance with TS00 General Requirements for Certification of Fire Protection Products The undermentioned products of 35 Rocky Lane, Aston,
More informationCERTIFICATE OF APPROVAL No CF 5350 TAIWAN DAEDALUS DOOR CONTROL CO. LTD
CERTIFICATE OF APPROVAL No CF 5350 This is to certify that, in accordance with TS00 General Requirements for Certification of Fire Protection Products The undermentioned products of TAIWAN DAEDALUS DOOR
More informationCERTIFICATE OF APPROVAL No CF 388. Allegion (UK) LTD
CERTIFICATE OF APPROVAL No CF 88 This is to certify that, in accordance with TS00 General Requirements for Certification of Fire Protection Products The undermentioned products of Allegion (UK) LTD 5 Rocky
More informationCERTIFICATE OF APPROVAL No CF 5507 CONSORT ARCHITECTURAL HARDWARE LTD
1 CERTIFICATE OF APPROVAL No CF 5507 This is to certify that, in accordance with TS00 General Requirements for Certification of Fire Protection Products The undermentioned products of 29-31 Lower Loveday
More informationCERTIFICATE OF APPROVAL No CF 850 ZOO HARDWARE LIMITED
CERTIFICATE OF APPROVAL No CF 850 1 This is to certify that, in accordance with TS00 General Requirements for Certification of Fire Protection Products The undermentioned products of Unit B, Dukes Drive,
More informationIntroduction of MSBC Secure India Pvt Ltd. Manufacturer & Installer of Fire Resistance Timber Doorsets
Introduction of MSBC Secure India Pvt Ltd Manufacturer & Installer of Fire Resistance Timber Doorsets Introduction MSBC Secure India Pvt Ltd MSBC Secure is a pioneer in the Door industry having vast knowledge
More informationCERTIFICATE OF APPROVAL No CF 646 EUROSPEC ARCHITECTURAL HARDWARE LIMITED
CERTIFICATE OF APPROVAL No CF 66 This is to certify that, in accordance with TS00 General Requirements for Certification of Fire Protection Products The undermentioned products of EUROSPEC ARCHITECTURAL
More informationFIRE DOORS RHUL REQUIREMENTS
Fire Safety Technical Guide FIRE DOORS RHUL REQUIREMENTS This guide draws together the general requirements of a range of published standards and reference documents and is to be used in addition to any
More informationCERTIFICATE OF APPROVAL No CF 494 HOPPE (UK) LIMITED
CERTIFICATE OF APPROVAL No CF 494 1 This is to certify that, in accordance with TS00 General Requirements for Certification of Fire Protection Products The undermentioned products of Gailey Park Industrial
More informationCERTIFICATE OF APPROVAL No CF 5516 ALLGOOD PLC
CERTIFICATE OF APPROVAL No CF 5516 1 This is to certify that, in accordance with TS00 General Requirements for Certification of Fire Protection Products The undermentioned products of 63-83 Brearley street,
More informationCERTIFICATE OF APPROVAL No CF 5118 ASSA ABLOY LTD
CERTIFICATE OF APPROVAL No CF 5118 This is to certify that, in accordance with TS00 General Requirements for Certification of Fire Protection Products The undermentioned products of School Street, Willenhall,
More informationCERTIFICATE OF APPROVAL No CF 5506 ALLEGION (UK) LIMITED
CERTIFICATE OF APPROVAL No CF 5506 1 This is to certify that, in accordance with TS00 General Requirements for Certification of Fire Protection Products The undermentioned products of 35 Rocky Lane, Aston,
More informationCERTIFICATE OF APPROVAL No CF 689 BOSS DOOR CONTROLS
CERTIFICATE OF APPROVAL No CF 689 This is to certify that, in accordance with TS00 General Requirements for Certification of Fire Protection Products The undermentioned products of 4 Rutherford Square,
More informationCERTIFICATE OF APPROVAL No CF 252 GEZE UK LIMITED
CERTIFICATE OF APPROVAL No CF 252 This is to certify that, in accordance with TS00 General Requirements for Certification of Fire Protection Products The undermentioned products of Blenheim Way, Fradley
More informationIDD 033C - Fire door sets
IDD 033C - Fire door sets Why are fire door sets important? Fire doors are one of the most important features of a building s fire precautions and have two key functions: To protect escape routes from
More informationFire Doors Technical Guidance
Fire Doors Technical Guidance Introduction Buildings are compartmented to delay the spread of fire from one area to another. The compartments are usually linked by doors to allow for passage of traffic
More informationAgrément Certificate 92/2841 website: Product Sheet 1
Lorient Polyproducts Ltd Endeavour House Fairfax Road Heathfield Industrial Estate Newton Abbot Devon TQ12 6UD Tel: 01626 834252 Fax: 01626 833166 Page 1 of 1 Agrément Certificate e-mail: mktg@lorientuk.com
More informationCERTIFICATE OF APPROVAL No CF 5179 LORIENT POLYPRODUCTS LIMITED
CERTIFICATE OF APPROVAL No CF 5179 This is to certify that, in accordance with TS00 General Requirements for Certification of Fire Protection Products The undermentioned products of Endeavour House, Fairfax
More informationCOLOUR YOUR WORLD HYGIENIC CLADDING SYSTEMS
COLOUR YOUR WORLD HYGIENIC CLADDING SYSTEMS Welcome TRANSFORM YOUR HOME OR BUSINESS Stunning transformations for your home or business... Welcome to WECLADANYWALL Ltd, the only company in the UK that specializes
More informationCERTIFICATE OF APPROVAL No CF 5530 TALLERES DE ESCORIAZA S.A.U.
CERTIFICATE OF APPROVAL No CF 5530 1 This is to certify that, in accordance with TS00 General Requirements for Certification of Fire Protection Products The undermentioned products of Barrio de Ventas
More informationCI/SfB (32.5) Ro8 (K2) ACOUSTIC SEALING SYSTEMS FOR DOOR ASSEMBLIES
CI/SfB (32.5) Ro8 (K2) ACOUSTIC ING SYSTEMS FOR DOOR ASSEMBLIES We ve been designing and manufacturing high performance sealing systems for over 35 years. And we re passionate about the products we make.
More informationCERTIFICATE OF APPROVAL No CF 388 INGERSOLL RAND SECURITY TECHNOLOGIES - BRITON
CERTIFICATE OF APPROVAL No CF 88 This is to certify that, in accordance with TS00 General Requirements for Certification of Fire Protection Products The undermentioned products of Bescot Crescent, Walsall,
More informationSchedule of works required for Fire Protection in a 2 Storey semi-detached/terraced house
Schedule of works required for Fire Protection in a 2 Storey semi-detached/terraced house THIS DOES NOT COVER 3 STOREY PROPERTIES you must consult with the Private Sector Housing Team on any 3 storey property.
More informationCERTIFICATE OF APPROVAL No CF 810 HOPPE (UK) LIMITED
This is to certify that, in accordance with TS00 General Requirements for Certification of Fire Protection Products The undermentioned products of HOPPE (UK) LIMITED Gailey Park, Gravelly Way, Standeford,
More informationCylinder Mortice Dead lock Lockcase(mm) A=87 Backset (mm) B=55. Follower (mm) 8 Latch Bolt
Product ID: KL.1902 Name: Cylinder Mortice Dead lock Lockcase(mm) A=87 Backset (mm) B=55 Centres C=N/A Follower (mm) 8 Latch Bolt N/A Mechanism Euro- Profile Forend Finish SSS Rebates available (mm) KL.1902A
More informationCERTIFICATE OF APPROVAL No CF 117 DORMA UK LTD
CERTIFICATE OF APPROVAL No CF 117 1 This is to certify that, in accordance with TS00 General Requirements for Certification of Fire Protection Products The undermentioned products of Wilbury Way, Hitchin,
More informationFire Door Maintenance Guide.
Fire Door Maintenance Guide http://www.c-sgroup.co.uk/products/acrovyn-impact-resistant-doors/ Introduction Fire Doors are a critical safety feature of any building in which people work or visit, as they
More information1.4 Provide and fix the following ironmongery.
Schedule of works required for Fire Protection in a first & second floor purpose built masionette above shops where the exit door is at first floor level. THIS DOES NOT COVER NORMAL 3 STOREY PROPERTIES
More informationMaintenance. Why Maintain Fire Doors? Regulations
Introduction Fire doors are commonly overlooked as an essential part of a commercial or public building maintenance regime. However, fire doors help sub-divide a building into compartments, slowing down
More informationTECHNICA DORMA. Controlled. d Door Closing. Closerss. appended hereto:
CERTIFICATE OF APPROVALL No CF This is to certify that, in accordance with TS00 General Requirements for Certification of Fire Protection Products The undermentioned products of UK LIMITE ED Wilbury Way,
More informationTimber Doorsets For Every Application. ASSA ABLOY, the global leader in door opening solutions
Timber Doorsets For Every Application ASSA ABLOY, the global leader in door opening solutions 2 1 ASSA ABLOY Market leaders in door solutions ASSA ABLOY is the world s leading manufacturer and supplier
More informationF O C U S D O O R C L O S E R S
(3) - Door Closers.qxp_(3) - Door Closers Art 14/02/2014 16:14 Page 2 F O C U S D O O R C L O S E R S KD.915 With cover Successfully Tested to EN 1154 4 8 5 1 1 3 2 Adjustable 2 to 5 by Spring Closer opening
More informationCERTIFICATE OF APPROVAL No CF 5527 TALLERES DE ESCORIAZA S.A.U.
CERTIFICATE OF APPROVAL No CF 5527 1 This is to certify that, in accordance with TS00 General Requirements for Certification of Fire Protection Products The undermentioned products of Bo Ventas, 35 E-20305
More informationProduct Data Sheet. Astro Strip
Product Data Sheet Astro Strip Revision 4 - September 2018 Astroflame (Fireseals) LTD : Unit 8, I.O Centre : Stephenson Road : Segensworth : Fareham : PO15 5RU T - 01329 844500 : F - 01329 844600 : : Astro
More informationGuide to Fire and Escape Doors: Part 1 - What are they? Produced by the Guild of Architectural Ironmongers Sponsored by Abloy UK
Guide to Fire and Escape Doors: Part 1 - What are they? Produced by the Guild of Architectural Ironmongers Sponsored by Abloy UK www.gai.org.uk Introduction This will be a brief overview of the subject,
More informationCERTIFICATE OF APPROVAL No CF 145 GEZE LIMITED
CERTIFICATE OF APPROVAL No CF 145 This is to certify that, in accordance with CERTIFIRE s Rules for Certification The undermentioned products of GEZE LIMITED Blenheim Way, Fradley Park, Lichfield, WS1
More informationCERTIFICATE OF APPROVAL No CF 392 EXIDOR LIMITED
CERTIFICATE OF APPROVAL No CF 392 1 This is to certify that, in accordance with TS00 General Requirements for Certification of Fire Protection Products The undermentioned products of Progress Drive, Cannock,
More informationPANIC EXIT HARDWARE DX-500 Serie
PANIC EXIT HARDWARE DX-500 Serie Explanation of European standards The standards EN 1125 and EN 179 were created at the European level with the acceptance and cooperation of the Dutch standards committee.
More information30 Minute Firedoor. 30 minute firedoor
30 minute firedoor 30 Minute Firedoor Rockdoor design and manufacture bespoke 30 minute accredited Firedoors in a pre-hung fire door set, helping house builders, local authorities and contractors to meet
More informationTHE HOME OF REACTIVE PROTECTION SYSTEMS
THE HOME OF REACTIVE PROTECTION SYSTEMS CONTENTS Page Introduction 1 Role of air transfer grilles 1 Definitions and functions 1 Fire performance requirements 2 Varieties of air transfer grilles 3 Recommended
More informationDIVISION 10 SPECIALTIES
DIVISION 10 SPECIALTIES 11/11 SECTION 10 21 13.16 PLASTIC LAMINATE TOILET COMPARTMENTS PART 1 - GENERAL 1.01 SECTION INCLUDES Plastic laminate toilet compartments, urinal screens, head rail braced. 1.02
More informationNFPA 80 Overview January 21, 2016
NFPA 80 Overview January 21, 2016 Kristin Bigda, P.E. Senior Fire Protection Engineer National Fire Protection Association Presenter Kristin Bigda, P.E. Senior Fire Protection Engineer, NFPA Building Fire
More informationSTC 46 3-Sided Paired Frame (Double Rabbet Only)
(Toll Free) Phone 866-452-1845 Fax 910-452-1848 STC 46 3-Sided Paired Frame (Double Rabbet Only) FRAME PART DIMENSIONS E E THROAT THROAT MINIMUM 3 5/16" MAXIMUM 13" D A=Jamb Depth MINIMUM 4 5/16" MAXIMUM
More informationCERTIFICATE OF APPROVAL No CF 111 INGERSOLL RAND SECURITY TECHNOLOGIES - BRITON
CERTIFICATE OF APPROVAL No CF 111 This is to certify that, in accordance with TS00 General Requirements for Certification of Fire Protection Products The undermentioned products of Bescot Crescent, Walsall,
More informationCERTIFICATE OF APPROVAL No CF 267. DORMA UK LIMITED Wilbury Way, Hitchin, Hertfordshire SG4 0AB Tel: Fax:
CERTIFICATE OF APPROVAL No CF 267 This is to certify that, in accordance with TS00 General Requirements for Certification of Fire Protection Products The undermentioned products of DORMA UK LIMITED Wilbury
More informationthe composite collection Discover the perfect composite door for your home
the composite collection Discover the perfect composite door for your home Our Composite Door Collection is a breakthrough in door technology, combining proven levels of high security with incredible good
More informationCl/SfB (32.5) Ro8 (K2) Specialised Fire Resistant Door Hardware
Cl/SfB (32.5) Ro8 (K2) Specialised Fire Resistant Door Hardware protecting against smoke and fire Fire and smoke protection measures are an essential, lifesaving precaution in a building. What s more,
More informationLoss Prevention Standard
Loss Prevention Standard LPS 1056: Issue 6.2 Requirements for the LPCB approval and listing of fire doorsets, lift landing doors and shutters This Loss Prevention Standard is the property of BRE Global
More informationCERTIFICATE OF APPROVAL No CF 520 ASSA ABLOY LTD T/A ASSA ABLOY SECURITY DOORS
CERTIFICATE OF APPROVAL No CF 520 1 This is to certify that, in accordance with TS00 General Requirements for Certification of Fire Protection Products The undermentioned products of 21 Ferguson Drive,
More informationSunshine Manufactured Structures, Inc.
Sunshine Manufactured Structures, Inc. MATERIALS AND COLOR SELECTIONS VCG Walls (Vinyl Covered Gypsum) Looma Beige Savannah Rose Looma Beige shown with Bleached Sands Carpet Looma Beige shown with Spruce
More informationThe Association for Specialist Fire Protection
The Association for Specialist Fire Protection The Role of Fire Doors, Frames and Fire Seals, Door Hardware Maintenance and Replacement John Fletcher Technical Consultant British Woodworking Federation
More informationSeries 47 Elegance. Custom Made Roller Blinds. Product Information. Elegance Manual - Version Page 1
Series 47 Elegance Custom Made Roller Blinds Product Information Elegance Manual - Version 101215 Page 1 Elegance 1. Fabrics. Custom Made Roller Blinds a. Viewty Plain i. NN12 White ii. NN15 Monaco Snow
More informationFIRE DOORS - GENERAL UCL OVERVIEW AND REQUIREMENTS
Fire Safety Technical Note FIRE DOORS - GENERAL UCL OVERVIEW AND REQUIREMENTS Fire Door Provision In UCL Buildings - what you need to know: Mandatory - all doors on main traffic and circulation routes,
More informationManaging Fire Safety in your building: Fire Doors Inspections. Part of the KCC Architectural Group
Managing Fire Safety in your building: Fire Doors Inspections Part of the KCC Architectural Group 2 Fire Door Inspections 3 The unavoidable truth Fire doors are a crucial part of any public, commercial
More informationGuide to the use of Smoke Seals in Doorsets
Information Sheet No. 3 Intumescent Fire Seals Association Guide to the use of Smoke Seals in Doorsets THE HOME OF REACTIVE PROTECTION SYSTEMS CONTENTS Page Effect of Smoke 1 The Role of the Doorstop 1
More informationEasy-action Door Closer DORMA TS83
Easy-action Door Closer DORMA TS83 DORMA TS 83 Easy-action Door Closer The multi-function, multi-purpose door closer Outstanding versatility. Quality assured. Tested to EN 1154. Decades of experience have
More informationCERTIFICATE OF APPROVAL No CF 136
certifire CERTFCATE OF APPROVAL No CF 136 This is to certify that, in accordance with TSOOGeneral Requirements for Certification of Fire Protection Products The undermentioned products of lorent POl YPRODUCTS
More informationFLAMEBREAK. Rev.D Mechanical Performances - General: TM
FLAMEBREAK Mechanical Performances 1 Mechanical Performances - General: NOTE: Doorsets using FLAMEBREAK based doors have been tested to performances that exceed the DD171 / BS EN 1192 minimum requirements
More informationARCHITECTURAL FABRICS
ARCHITECTURAL FABRICS 680 BLACK 904 PUTTY 251 SAND 34 OLIVE 36 CHOCOLATE 4 LEMON 205 45 MATT Polyplan introduces a odern eleent to architectural fabrics with the 45 Matt range. Matt finishes are the new
More informationSliding Sash Windows. Traditional appearance, modern performance
Sliding Sash Windows Traditional appearance, modern performance 02 Welcome Thank you for considering our company for your Sliding Sash Windows. Our brochure gives you some examples of the amazing windows
More informationIntumescent Fire Seals
Trade Name: ASTRO STRIP Intumescent Fire Seals Certifire Approved Fire Seals & Smoke Seals Intumescent Fire Seals Astrostrip FO - fire only seals. Intumescent seals for use where no smoke sealing is required.
More informationthe composite collection Discover the perfect composite door for your home
the composite collection Discover the perfect composite door for your home Our Composite Door Collection is a breakthrough in door technology, combining proven levels of high security with incredible good
More informationPalusol Palusol SW. The innovative choice for intelligent fire protection. Palusol in the web:
Palusol Palusol SW The innovative choice for intelligent fire protection Palusol in the web: www.palusol.com Palusol and Palusol SW Palusol fire-protection panels are classified as noncombustible building
More informationHigh Security Locking. Product Catalogue
High Security Locking Product Catalogue An ASSA ABLOY Group company 2 Adams Rite Europe Limited About the company Adams Rite was formed in 1946 in Los Angeles, California and over the years we have created
More informationHurst nxt-gen. Shaping the future of composite doors
Hurst nxt-gen Shaping the future of composite doors Hurst nxt-gen is the latest in composite door technology CONTENTS 04 Hurst nxt-gen 06 nxt-gen Half Moon 3 08 nxt-gen Half Moon 10 nxt-gen 4/2 Glazed
More informationFire Rated Door Assemblies: Compliant Designs
Fire Rated Door Assemblies: Compliant Designs Steel Door Institute www.steeldoor.org AIA Provider #G389 Course #: SDIFIRE 1 HSW CE hour 1 Credit(s) earned on completion of this course will be reported
More informationNewstar Door Closing Devices & Accessories
Newstar Door Closing Devices & Accessories NEWSTAR form and function for life Surface overhead door closers Bary Cam Low opening force surface track arm door closer SL-144 SIL SNP PCP 30 Functional Criteria
More informationCERTIFICATE OF COMPLIANCE
Date : 13th September 2017 CERTIFICATE OF COMPLIANCE TEST REPORT NUMBER Assessment Reports are not acceptable DATE OF ISSUE DATE OF EXPIRY FACTORY/ MANUFACTURER This certificate of compliance validates
More informationRegulatory Reform (Fire Safety) Order 2005
Regulatory Reform (Fire Safety) Order 2005 Solutions for acoustic, smoke and fire containment What is the RRO? The Regulatory Reform (Fire Safety) Order 2005 came into force almost ten years ago in England
More informationthe composite collection Discover the perfect composite door for your home
the composite collection Discover the perfect composite door for your home Our Composite Door Collection is a breakthrough in door technology, combining proven levels of high security with incredible good
More informationPanic & emergency exit devices. CFPA-E Guideline No 2:2013 F
Panic & emergency exit devices CFPA-E Guideline No 2:2013 F FORWORD The European fire protection associations have decided to produce common guidelines in order to achieve similar interpretation in the
More informationS-200 BEAUTIFULLY ENGINEERED ALUMINIUM DOORS MAKE A GRAND ENTRANCE
S-200 BEAUTIFULLY ENGINEERED ALUMINIUM DOORS MAKE A GRAND ENTRANCE S-200. WHERE FORM MEETS FUNCTION 1654 The S-200 Series, Spitfire s series of beautiful designer entrance doors, represents one of the
More informationFIRE DOOR SAFETY. Important information for leaseholders about fire doors in your property. September 2017 Version 1
FIRE DOOR SAFETY Important information for leaseholders about fire doors in your property. September 2017 Version 1 It s important that everybody knows their role in keeping themselves and others safe
More information