Introduction of MSBC Secure India Pvt Ltd. Manufacturer & Installer of Fire Resistance Timber Doorsets

Size: px
Start display at page:

Download "Introduction of MSBC Secure India Pvt Ltd. Manufacturer & Installer of Fire Resistance Timber Doorsets"

Transcription

1 Introduction of MSBC Secure India Pvt Ltd Manufacturer & Installer of Fire Resistance Timber Doorsets

2 Introduction MSBC Secure India Pvt Ltd MSBC Secure is a pioneer in the Door industry having vast knowledge and experience of over 25 years, in the UK; now in India. We are Manufacturer and Installer of Specialist Security and Fire resistant Timber Doorset. Our Manufacturing and joinery facility in Gujarat state consist of Sq. Ft. production line. We are one of the leading Manufacturer in India who provides a one stop design, build and installation services. All our Fire Doorsets are fully certified to meet European and Indian standards, Including BS 476 Part 22 and IS 3614 Part 2: 1992.

3 Fire Resistant Doorset What is Fire Resistant Doorset? A Doorset is a complete assembly with a fire-resistance rating (i.e. 30min, 60min, 120min) fitted as part of a passive fire protection system to reduce the spread of fire and smoke between compartments and to enable way out from a building. What Does a Doorset Include? The Doorset includes door leaf with fire resistance hardware, hardwood frame which consist of intumescent strip and smoke seal, typically called a Doorset fixed on to a structure that holds the fire door assembly in place.

4 Fire Resistant Doorset Components Fire Resistant Door Leaf Door leaf moisture content to be - 8% -12%

5 Fire Resistant Doorset Components Fire Resistant Hardwood Frame 30 Min. Hardwood Frame: Minimum 510 kg/m 3 Density Required. 60 Min. Hardwood Frame: Minimum 640 kg/m 3 Density Required. 120 Min. Hardwood Frame: Minimum 850 kg/m 3 Density Required. Kiln Dried Framing timber moisture content to be 12% -16%.

6 Fire Resistant Doorset Components Intumescent strip and smoke seal rebated into the frame Smoke seal Withstand up to Temperature 190 C Intumescent Strip Activates at Temperature 140 C

7 Fire Resistant Doorset Components Fire Resistant Hardware

8 Fire Resistant Doorset Components Hardware cut-outs requires Intumescent lining in order to meet fire resistance Intumescent Lining Installed in Hardware Cut - Outs

9 Fire Resistant Doorset Manufacturing Process Cutting Edge Banding Drilling & Cut Outs Cut Outs Frame Making Door Making Pre-hanging Finishing

10 Security & Fire Resistant Doorset MADE IN INDIA We strictly follow Manufacturing processes for fire resistance Doorsets to comply with BS 476 Part 22 and IS 3614 Part 2: 1992.

11 Fire Resistance Doorset Installation Anchor fasteners for frame fixing. Fire resistant foam to fill gaps between frame and wall. All our Installation carried out by skilled operative. If fire doors are not Installed properly their fire resistance capabilities can be seriously compromised.

12 Fire Resistant Doorset Required Norms Description Norms Fire Rating Non Load Bearing Partitions (Kitchen & Internal Doors) NBC Clause MFS Circular MFS/36-G/2014/ min For Dwelling Unit Separation (Main Door) NBC Clause MFS Circular MFS/36-G/2014/ min Exit Ways Access Corridors (Corridor Door) NBC Clause min Riser Shaft Door & Hatch NBC Clause min Exit Ways to Stairways (Staircase Doors) NBC Clause min

13 Our Year s of Experience at your Disposal Hands-on Fire Resistant Doorset Consultation

14 Passive Fire Protection Awareness Campaign We have been actively involved with Corporates well as Government Sectors in Passive Fire Protection Awareness Campaign as a part of Corporate & Social Responsibility. Topics Covered in our Seminar What is Fire Resistant Doorset? What are the Components Includes? Applications of Fire Resistant Doorset. Fire Resistance Doorset Compliance. Fire Resistant Doorset Legislation in India. Fire Doorset Testing & assessment Process.

15 Hands on Training for Fire Brigade Officers Our Training Demonstrates how to Gain Forced Entry in Critical Situations Within 3 Minutes on Fire Resistance Doorset

16 Thank You

Managing Fire Safety in your building: Fire Doors Inspections. Part of the KCC Architectural Group

Managing Fire Safety in your building: Fire Doors Inspections. Part of the KCC Architectural Group Managing Fire Safety in your building: Fire Doors Inspections Part of the KCC Architectural Group 2 Fire Door Inspections 3 The unavoidable truth Fire doors are a crucial part of any public, commercial

More information

Maintenance. Why Maintain Fire Doors? Regulations

Maintenance. Why Maintain Fire Doors? Regulations Introduction Fire doors are commonly overlooked as an essential part of a commercial or public building maintenance regime. However, fire doors help sub-divide a building into compartments, slowing down

More information

Regulatory Reform (Fire Safety) Order 2005

Regulatory Reform (Fire Safety) Order 2005 Regulatory Reform (Fire Safety) Order 2005 This document has been prepared by ASDMA (Architectural & Specialist Door Manufacturers Association) to provide for guidance for Responsible Persons in respect

More information

Schedule of works required for Fire Protection in a 2 Storey semi-detached/terraced house

Schedule of works required for Fire Protection in a 2 Storey semi-detached/terraced house Schedule of works required for Fire Protection in a 2 Storey semi-detached/terraced house THIS DOES NOT COVER 3 STOREY PROPERTIES you must consult with the Private Sector Housing Team on any 3 storey property.

More information

1.4 Provide and fix the following ironmongery.

1.4 Provide and fix the following ironmongery. Schedule of works required for Fire Protection in a first & second floor purpose built masionette above shops where the exit door is at first floor level. THIS DOES NOT COVER NORMAL 3 STOREY PROPERTIES

More information

IDD 033C - Fire door sets

IDD 033C - Fire door sets IDD 033C - Fire door sets Why are fire door sets important? Fire doors are one of the most important features of a building s fire precautions and have two key functions: To protect escape routes from

More information

CERTIFICATE OF APPROVAL No CF 5350 TAIWAN DAEDALUS DOOR CONTROL CO. LTD

CERTIFICATE OF APPROVAL No CF 5350 TAIWAN DAEDALUS DOOR CONTROL CO. LTD CERTIFICATE OF APPROVAL No CF 5350 This is to certify that, in accordance with TS00 General Requirements for Certification of Fire Protection Products The undermentioned products of TAIWAN DAEDALUS DOOR

More information

Managing Fire Safety in Occupied Buildings FM Ireland Fire Safety Theatre

Managing Fire Safety in Occupied Buildings FM Ireland Fire Safety Theatre FM Ireland Fire Safety Theatre Welcome David O Reilly FIFireE Association for Specialist Fire Protection in Ireland Institution of Fire Engineers Republic of Ireland Branch President International General

More information

Fire Door Maintenance Guide.

Fire Door Maintenance Guide. Fire Door Maintenance Guide http://www.c-sgroup.co.uk/products/acrovyn-impact-resistant-doors/ Introduction Fire Doors are a critical safety feature of any building in which people work or visit, as they

More information

CERTIFICATE OF APPROVAL No CF 530 HOPPE (UK) LIMITED

CERTIFICATE OF APPROVAL No CF 530 HOPPE (UK) LIMITED CERTIFICATE OF APPROVAL No CF 530 This is to certify that, in accordance with TS00 General Requirements for Certification of Fire Protection Products The undermentioned products of Gailey Park Industrial

More information

Fire Protection. Intumescent fire and smoke seals for door assemblies

Fire Protection. Intumescent fire and smoke seals for door assemblies Fire Protection Intumescent fire and smoke seals for door assemblies Intumescent Seals Fire Protection Quality you can trust Exitex offer a wide range of fully tested intumescent strips, glazing seals

More information

Fire Risk Assessment. Index. Part 1 Introduction Part 2 The Fire Risk Assessment Part 3 The Management Action Plan

Fire Risk Assessment. Index. Part 1 Introduction Part 2 The Fire Risk Assessment Part 3 The Management Action Plan Fire Risk Assessment Worksafe Solutions Consultancy Ltd 67 Flitwick Road Maulden Bedfordshire, MK45 2BJ Tel: 01525 406787 email enquiries@worksafesoultions.co.uk Index Part 1 Introduction Part 2 The Fire

More information

CERTIFICATE OF APPROVAL No CF 5542 ASSA ABLOY SECURITY SOLUTIONS

CERTIFICATE OF APPROVAL No CF 5542 ASSA ABLOY SECURITY SOLUTIONS CERTIFICATE OF APPROVAL No CF 5542 This is to certify that, in accordance with TS00 General Requirements for Certification of Fire Protection Products The undermentioned products of 11B Street, Jebel Ali

More information

Unit 2 Fire Safety (Zone 1)

Unit 2 Fire Safety (Zone 1) IFE Level 3 Diploma in Fire Safety and Fire Science Unit 2 Fire Safety (Zone 1) Examiner Report March 2018 Introduction 42% of candidates attained a Pass. Half of the candidates that attained a Pass secured

More information

FIRE DOORS RHUL REQUIREMENTS

FIRE DOORS RHUL REQUIREMENTS Fire Safety Technical Guide FIRE DOORS RHUL REQUIREMENTS This guide draws together the general requirements of a range of published standards and reference documents and is to be used in addition to any

More information

CERTIFICATE OF APPROVAL No CF 530 HOPPE (UK) LIMITED

CERTIFICATE OF APPROVAL No CF 530 HOPPE (UK) LIMITED CERTIFICATE OF APPROVAL No CF 530 1 This is to certify that, in accordance with TS00 General Requirements for Certification of Fire Protection Products The undermentioned products of Gailey Park Industrial

More information

Life Safety and Fire Resistant Glazing Systems

Life Safety and Fire Resistant Glazing Systems Life Safety and Fire Resistant Glazing Systems Kevin Hulin CEO, Mann McGowan Group Agenda GGF Introduction GGF and The Fire Resistant Glazing Group (FRGG) Fire Testing, Reports, Assessments and 3rd Party

More information

CERTIFICATE OF APPROVAL No CF 5494 ASSA ABLOY AB

CERTIFICATE OF APPROVAL No CF 5494 ASSA ABLOY AB CERTIFICATE OF APPROVAL No CF 5494 1 This is to certify that, in accordance with TS00 General Requirements for Certification of Fire Protection Products The undermentioned products of Klarabergsviadukten

More information

CERTIFICATE OF APPROVAL No CF 391 UNION ARCHITECTURAL HARDWARE

CERTIFICATE OF APPROVAL No CF 391 UNION ARCHITECTURAL HARDWARE CERTIFICATE OF APPROVAL No CF 391 1 This is to certify that, in accordance with TS00 General Requirements for Certification of Fire Protection Products The undermentioned products of School Street, Willenhall,

More information

- CONSTRUCTION FIRE SAFETY STANDARDS

- CONSTRUCTION FIRE SAFETY STANDARDS SGG15 - CONSTRUCTION FIRE SAFETY STANDARDS 1) Construction Planning All construction sites shall plan and sequence their construction activities to ensure the early installation and operation of permanent

More information

STEEL DUCT - FIRE RATED CLADDING INSTALLATION MANUAL

STEEL DUCT - FIRE RATED CLADDING INSTALLATION MANUAL 14SH200001022 STEEL DUCT - FIRE RATED CLADDING INSTALLATION MANUAL DUCTLINER GS - VENTILATION, SMOKE OUTLET AND KITCHEN EXTRACT DUCT SYSTEMS Tested under BS 476: Part 24: 1987 Fire tests building materials

More information

FIRE DOOR SAFETY. Important information for leaseholders about fire doors in your property. September 2017 Version 1

FIRE DOOR SAFETY. Important information for leaseholders about fire doors in your property. September 2017 Version 1 FIRE DOOR SAFETY Important information for leaseholders about fire doors in your property. September 2017 Version 1 It s important that everybody knows their role in keeping themselves and others safe

More information

Princess Court Cornbrook Park Road Old Trafford Manchester M15 4FE

Princess Court Cornbrook Park Road Old Trafford Manchester M15 4FE Princess Court Cornbrook Park Road Old Trafford Manchester M15 4FE Prepared by: Peter Golding Tech IOSH and Mark Alderson BSc Hons IEng MIFireE (IFE 0002248) Safety Management (UK) Ltd Holme Suite Clawthorpe

More information

Fire Risk Assessment

Fire Risk Assessment Fire Risk Assessment Carr House HS.F.119 (rev03) delivering promises, improving lives Contents 1 Premises particulars... 1 2 General statement of policy... 1 3 Management system... 1 4 General description

More information

The Fire Resistance Performance Of Timber Or Mineral Composite Based Insulated Doorsets When Fitted With D & E Architectural Hardware Spring Hinges

The Fire Resistance Performance Of Timber Or Mineral Composite Based Insulated Doorsets When Fitted With D & E Architectural Hardware Spring Hinges Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 (0) 1925 655 116 F : +44 (0) 1925 655 419 E : warrington@exova.com W: www.exova.com Title: The Fire Resistance Performance

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK ISO/IEC 17065:2012 to provide product conformity 20 Park Street Princes Risborough Buckinghamshire HP27 9AH Contact: Ian Woodhouse Tel: +44

More information

fire resistance testing

fire resistance testing fire resistance testing Chiltern International Fire and Chiltern Dynamics, as part of the BM TRADA Group, have more than 70 years experience in providing practical solutions in the field of testing and

More information

- CONSTRUCTION FIRE SAFETY STANDARDS

- CONSTRUCTION FIRE SAFETY STANDARDS SGG15 - CONSTRUCTION FIRE SAFETY STANDARDS 1) Hot Work Permits All construction sites shall implement a system of Hot Work Permits for all work activities that generate heat, sparks or flames. All of the

More information

BHP High Rise Controlled Cold Smoke Tests. Background

BHP High Rise Controlled Cold Smoke Tests. Background Background Brent Housing Partnership (BHP) is an ALMO responsible for the London Borough of Brent s 12,000 social housing properties. BHP are in the process of undertaking a major upgrade to passive fire

More information

dhf General Information Automated Gates Guidance for enforcement bodies

dhf General Information Automated Gates Guidance for enforcement bodies Automated Gates Guidance for enforcement bodies www.dhfonline.org.uk Contents About dhf 1 Applicable legislation & standards 2 Annex A 4 Useful links 5 About dhf dhf represents the key manufacturers and

More information

C/S Fire Rated Door Edge Protection Product Range FD60

C/S Fire Rated Door Edge Protection Product Range FD60 DE-06 Plain Edge Protector Seal Options used with/without s Range FD60 Product Range FD60 Intumescent & Smoke seal (brush seal) DE-04 with Intumescent Seal DE-05 with Intumescent & Smoke Seal (twin fin)

More information

CERTIFICATE OF APPROVAL No CF 5075 EXIDOR LIMITED

CERTIFICATE OF APPROVAL No CF 5075 EXIDOR LIMITED CERTIFICATE OF APPROVAL No CF 5075 This is to certify that, in accordance with TS00 General Requirements for Certification of Fire Protection Products The undermentioned products of Progress Drive, Cannock,

More information

Specification, installation & maintenance of fire doors: Technical Note 2

Specification, installation & maintenance of fire doors: Technical Note 2 Specification, installation & maintenance of fire doors: Technical Note 2 March 2016 You & Your Care \\raptor\user data\users\kbyard www.bdct.nhs.uk Karen Byard: Fire Officer Tel: 07946 413 331 Karen.byard@bdct.nhs.uk

More information

Fire Risk Assessment

Fire Risk Assessment Fire Risk Assessment Manor House HS.F.119 (rev03) delivering promises improving lives Contents 1 Premises particulars... 1 2 General statement of policy... 1 3 Management systems... 1 4 General description

More information

CERTIFICATE OF APPROVAL No CF 810 HOPPE (UK) LIMITED

CERTIFICATE OF APPROVAL No CF 810 HOPPE (UK) LIMITED This is to certify that, in accordance with TS00 General Requirements for Certification of Fire Protection Products The undermentioned products of HOPPE (UK) LIMITED Gailey Park, Gravelly Way, Standeford,

More information

ARCHITECTURAL IRONMONGERY. company overview

ARCHITECTURAL IRONMONGERY. company overview company overview WHO WE ARE Welling is a family owned and run Company based in Gloucestershire. We are suppliers of high quality architectural hardware and ironmongery, and associated products. We look

More information

Section 2 - Applications - General. Section 2A - FD30 Strebord 35+, 38+, 44 & Superpan with MDF & Wood Frames

Section 2 - Applications - General. Section 2A - FD30 Strebord 35+, 38+, 44 & Superpan with MDF & Wood Frames Section 2 - Applications - General Section 2A - FD30 Strebord 35+, 38+, 44 & Superpan with MDF & Wood Frames Section 2B - FD30 Strebord 35+, 38+, 44, Superpan & Strebord 54 with Steel Frames Section 2C

More information

Title: The Air Leakage Performance of Timber Doorsets fitted with NOR710 Smoke Seals in Accordance with BS 476: Part 31, Section 31.

Title: The Air Leakage Performance of Timber Doorsets fitted with NOR710 Smoke Seals in Accordance with BS 476: Part 31, Section 31. Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 (0) 1925 655 116 F : +44 (0) 1925 655 419 E : warrington@exova.com W: www.exova.com Title: The Air Leakage Performance of

More information

CERTIFICATE OF APPROVAL No CF 850 ZOO HARDWARE LIMITED

CERTIFICATE OF APPROVAL No CF 850 ZOO HARDWARE LIMITED CERTIFICATE OF APPROVAL No CF 850 1 This is to certify that, in accordance with TS00 General Requirements for Certification of Fire Protection Products The undermentioned products of Unit B, Dukes Drive,

More information

Cl/SfB (32.5) Ro8 (K2) Fire Resistant Glazing Systems

Cl/SfB (32.5) Ro8 (K2) Fire Resistant Glazing Systems Cl/SfB (32.5) Ro8 (K2) Fire Resistant Glazing Systems protecting against smoke and fire Fire and smoke protection measures are essential, lifesaving precautions in a building. What s more, they protect

More information

The Association for Specialist Fire Protection. Understanding Best Practice in passive fire protection

The Association for Specialist Fire Protection. Understanding Best Practice in passive fire protection The Association for Specialist Fire Protection Understanding Best Practice in passive fire protection Niall Rowan, Technical Officer Association for Specialist Fire Protection The Association for Specialist

More information

30 Minute Firedoor. 30 minute firedoor

30 Minute Firedoor. 30 minute firedoor 30 minute firedoor 30 Minute Firedoor Rockdoor design and manufacture bespoke 30 minute accredited Firedoors in a pre-hung fire door set, helping house builders, local authorities and contractors to meet

More information

CERTIFICATE OF APPROVAL No CF 5507 CONSORT ARCHITECTURAL HARDWARE LTD

CERTIFICATE OF APPROVAL No CF 5507 CONSORT ARCHITECTURAL HARDWARE LTD 1 CERTIFICATE OF APPROVAL No CF 5507 This is to certify that, in accordance with TS00 General Requirements for Certification of Fire Protection Products The undermentioned products of 29-31 Lower Loveday

More information

RISK ASSESSMENT & EMERGENCY PREPAREDNESS PLAN

RISK ASSESSMENT & EMERGENCY PREPAREDNESS PLAN RISK ASSESSMENT & EMERGENCY PREPAREDNESS PLAN RISK ASSESSMENT The phases of an emergency includes: 1. Risk assessment 2. Mitigation 3. Preparedness 4. Response 5. Recovery Areas of Risk includes: Naturally

More information

CONSTRUCTION PRODUCTS REGULATION 2011 DECLARATION OF PERFORMANCE

CONSTRUCTION PRODUCTS REGULATION 2011 DECLARATION OF PERFORMANCE Page 1 of 4 CONSTRUCTION PRODUCTS REGULATION 2011 DECLARATION OF PERFORMANCE DoP Number: HUK0022 1. Unique identification code of the product-type: AR880 Series Panic Bolt, AR882 Series Reversible Panic

More information

CERTIFICATE OF APPROVAL No CF 388. Allegion (UK) LTD

CERTIFICATE OF APPROVAL No CF 388. Allegion (UK) LTD CERTIFICATE OF APPROVAL No CF 88 This is to certify that, in accordance with TS00 General Requirements for Certification of Fire Protection Products The undermentioned products of Allegion (UK) LTD 5 Rocky

More information

CERTIFICATE OF APPROVAL No CF 5657 UNION ARCHITECTURAL HARDWARE

CERTIFICATE OF APPROVAL No CF 5657 UNION ARCHITECTURAL HARDWARE CERTIFICATE OF APPROVAL No CF 5657 1 This is to certify that, in accordance with TS00 General Requirements for Certification of Fire Protection Products The undermentioned products of School Street, Willenhall,

More information

Fire doors are a lifeline. When properly fitted and properly cared for they give vital minutes for people to safely escape from fire and smoke.

Fire doors are a lifeline. When properly fitted and properly cared for they give vital minutes for people to safely escape from fire and smoke. Fire Doors: A Guide About This Guide Fire doors are a lifeline. When properly fitted and properly cared for they give vital minutes for people to safely escape from fire and smoke. It s critical then that

More information

25 th November Title:

25 th November Title: Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 (0) 1925 655 116 F : +44 (0) 1925 655 419 E : warrington@exova.com W: www.exova.com Title: The Fire Resistance Performance

More information

FLAMEBREAK. Rev.D Mechanical Performances - General: TM

FLAMEBREAK. Rev.D Mechanical Performances - General: TM FLAMEBREAK Mechanical Performances 1 Mechanical Performances - General: NOTE: Doorsets using FLAMEBREAK based doors have been tested to performances that exceed the DD171 / BS EN 1192 minimum requirements

More information

Timber Doorsets For Every Application. ASSA ABLOY, the global leader in door opening solutions

Timber Doorsets For Every Application. ASSA ABLOY, the global leader in door opening solutions Timber Doorsets For Every Application ASSA ABLOY, the global leader in door opening solutions 2 1 ASSA ABLOY Market leaders in door solutions ASSA ABLOY is the world s leading manufacturer and supplier

More information

The Association for Specialist Fire Protection

The Association for Specialist Fire Protection The Association for Specialist Fire Protection The Role of Fire Doors, Frames and Fire Seals, Door Hardware Maintenance and Replacement John Fletcher Technical Consultant British Woodworking Federation

More information

CHAPTER 8: RISK ASSESSMENT & EMERGENCY PREPAREDNESS PLAN

CHAPTER 8: RISK ASSESSMENT & EMERGENCY PREPAREDNESS PLAN CHAPTER 8: RISK ASSESSMENT & EMERGENCY PREPAREDNESS PLAN RISK ASSESSMENT The phases of an emergency includes: 1. Risk assessment 2. Mitigation 3. Preparedness 4. Response 5. Recovery Areas of Risk includes:

More information

MAINTENANCE OF ESSENTIAL SAFETY MEASURES EXPLAINED (Building Regulations 2006)

MAINTENANCE OF ESSENTIAL SAFETY MEASURES EXPLAINED (Building Regulations 2006) MAINTENANCE OF ESSENTIAL SAFETY MEASURES EXPLAINED (Building Regulations 2006) 1. INTRODUCTION 1.1 Essential Safety Measures Defined Essential Safety Measures (previously called essential services) are

More information

REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT

REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT OVERALL COLOUR ACTION CODE RISK AMBER STATUTORY INSTRUMENT 2005:1541 REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT Address of Premises: Thuurock CCG, Civic Offices New Road Grays Responsible

More information

Emergency Lighting: what, when & how? Richard Caple MSc MSLL Lighting Applications Manager

Emergency Lighting: what, when & how? Richard Caple MSc MSLL Lighting Applications Manager Emergency Lighting: what, when & how? Richard Caple MSc MSLL Lighting Applications Manager What is emergency lighting? Legislation and standards Emergency lighting design Emergency lighting testing requirements

More information

BRISTOL: A History & Future.

BRISTOL: A History & Future. Fire Doors BRISTOL: A History & Future. In 1971, seven emirates joined forces to create the United Arab Emirates, with the goal of becoming a growing leader on an international scale. The UAE s focus has

More information

FIRE DOORS - GENERAL UCL OVERVIEW AND REQUIREMENTS

FIRE DOORS - GENERAL UCL OVERVIEW AND REQUIREMENTS Fire Safety Technical Note FIRE DOORS - GENERAL UCL OVERVIEW AND REQUIREMENTS Fire Door Provision In UCL Buildings - what you need to know: Mandatory - all doors on main traffic and circulation routes,

More information

GENERAL FIRE SAFETY TERMS & DEFINITIONS

GENERAL FIRE SAFETY TERMS & DEFINITIONS UCL Fire Technical Note - TN006 Fire Safety Technical Guide GENERAL FIRE SAFETY TERMS & DEFINITIONS Reference: BS4422-2005 Fire Safety Vocabulary - for further information and definitions BS EN ISO 13943-2000:

More information

CERTIFICATE OF APPROVAL No CF 5263 KCC ARCHITECTURAL

CERTIFICATE OF APPROVAL No CF 5263 KCC ARCHITECTURAL CERTIFICATE OF APPROVAL No CF 5263 This is to certify that, in accordance with TS00 General Requirements for Certification of Fire Protection Products The undermentioned products of Unit 1 Westgate Business

More information

Fire and Security Products and Services

Fire and Security Products and Services * www.redbooklive.com Fire and Security Products and Services Making LPCB Approval work for you Not all fire and security products and services on the market can be trusted in the event of a fire or attempted

More information

Title: WF Assessment Report No B. Prepared for: CHEMOLLI S.A.S. di Eros Chemolli & C. Via Fitta, Arco (TN), Italy

Title: WF Assessment Report No B. Prepared for: CHEMOLLI S.A.S. di Eros Chemolli & C. Via Fitta, Arco (TN), Italy Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 (0) 1925 655 116 F : +44 (0) 1925 655 419 E : warrington@exova.com W: www.exova.com Title: The Fire Resistance Performance

More information

COMMISSIONING OF LIFE SAFETY AND FIRE PROTECTION SYSTEMS: WHAT, WHERE AND HOW?

COMMISSIONING OF LIFE SAFETY AND FIRE PROTECTION SYSTEMS: WHAT, WHERE AND HOW? COMMISSIONING OF LIFE SAFETY AND FIRE PROTECTION SYSTEMS: WHAT, WHERE AND HOW? By: Ark Tsisserev, P.Eng. Senior Technical Manager Applied Engineering Solutions Ltd. CFAA Technical Seminar April 15, 2015

More information

Fire Risk Assessment

Fire Risk Assessment Fire Risk Assessment Trinity House HS.F.119 (rev02) delivering promises, improving lives Contents 1 Premises particulars... 1 2 General statement of policy... 1 3 Management systems... 1 4 General description

More information

CERTIFICATE OF FIRE APPROVAL

CERTIFICATE OF FIRE APPROVAL LR2009.030. CERTIFICATE OF FIRE APPROVAL This is to certify that The product(s) detailed below will be accepted for compliance with the applicable Lloyd s Register Rules and Regulations for use on offshore

More information

Passive fire protection. 6 Passive fire protection. 6.1 Fire compartmentation. Passive fire protection

Passive fire protection. 6 Passive fire protection. 6.1 Fire compartmentation. Passive fire protection 6 Inside buildings there are two types of fire protection systems: Active Fire Protection and Passive Fire Protection. Both systems should actively work together in the event of a fire. 6.1.1 The four

More information

CERTIFICATE OF APPROVAL No CF 494 HOPPE (UK) LIMITED

CERTIFICATE OF APPROVAL No CF 494 HOPPE (UK) LIMITED CERTIFICATE OF APPROVAL No CF 494 1 This is to certify that, in accordance with TS00 General Requirements for Certification of Fire Protection Products The undermentioned products of Gailey Park Industrial

More information

EVOLUTIONS FIRE PROTECTION

EVOLUTIONS FIRE PROTECTION Protect Your Property Today EVOLUTIONS FIRE PROTECTION Passive - Prevention - Protection Every building has a responsible individual. Now its time to make a responsible decision. TABLE OF CONTENTS 04 06

More information

CERTIFICATE OF APPROVAL No CF 392 EXIDOR LIMITED

CERTIFICATE OF APPROVAL No CF 392 EXIDOR LIMITED CERTIFICATE OF APPROVAL No CF 392 1 This is to certify that, in accordance with TS00 General Requirements for Certification of Fire Protection Products The undermentioned products of Progress Drive, Cannock,

More information

IS-ORANGE Envirograf. Orange Book. Ventilation. T +44 (0) F +44 (0)

IS-ORANGE Envirograf. Orange Book. Ventilation. T +44 (0) F +44 (0) IS-ORANGE-01-15 Orange Book Ventilation Envirograf Innovators - Developers - Manufacturers Passive Fire Prevention Products T +44 (0) 1304 842 555 F +44 (0) 1304 842 666 sales@envirograf.com www.envirograf.com

More information

KEEP THE FIRE FROM SPREADING

KEEP THE FIRE FROM SPREADING KEEP THE FIRE FROM SPREADING Fire might be a symbol of man s development in the world, but when it is out of control it could cause enormous damage to the surroundings. Especially when it comes to fire

More information

BWF-Certifire Fire Doors and Doorsets. Best Practice Guide

BWF-Certifire Fire Doors and Doorsets. Best Practice Guide BWF-Certifire Fire Doors and Doorsets Best Practice Guide 1 BWF-Certifire BWF-Certifire: The leading authority on fire door safety A fire door is a vital safety device engineered to save lives and property.

More information

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT SPORTS CENTRE

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT SPORTS CENTRE FIRE RISK ASSESSMENT SPORTS CENTRE BUILDING SUMMARY The building is used as a Sports Centre and contains a large sports hall with changing rooms, an office for staff and a fitness area. 1. Identification

More information

The Passive Fire Protection Handbook

The Passive Fire Protection Handbook Useful Contact Numbers Promat Technical Services Department Telephone: 01344 381 400 Fax: 01344 381 401 E-mail: technicaluk@promat.co.uk Promat Marketing Services Department Telephone: 01344 381 350 Fax:

More information

Welcome to the. Firestop Seminar. Hilti Technical and Engineering Support

Welcome to the. Firestop Seminar.  Hilti Technical and Engineering Support Welcome to the Firestop Seminar www.hilti.co.uk/technical Hilti Technical and Engineering Support 1 Agenda 1. Passive Fire Protection a) The Importance of Firestop b) What are the Regulations c) Test Criteria

More information

Guide to interpreting Markings for Single Axis Fire Doors Hinges

Guide to interpreting Markings for Single Axis Fire Doors Hinges Guide to interpreting Markings for Single Axis Fire Doors Hinges An overview of BS EN 1935: 2002: Building Hardware. Single Axis hinges as relates to Fire doors. INTRODUCTION. It is a criminal offence

More information

fire doors the burning issues From specification to maintenance the life cycle of a fire door explained guide

fire doors the burning issues From specification to maintenance the life cycle of a fire door explained guide fire doors the burning issues From specification to maintenance the life cycle of a fire door explained guide Passive Fire Protection Passive fire protection products are built into the fabric of a building,

More information

Window and Door Standards for Performance and Security. Russell Day Senior Technical Officer Glass and Glazing Federation

Window and Door Standards for Performance and Security. Russell Day Senior Technical Officer Glass and Glazing Federation Window and Door Standards for Performance and Security Russell Day Senior Technical Officer Glass and Glazing Federation The Standards BS EN 14351-1:2006+A2:2016 Windows and doors. Product standard, performance

More information

CERTIFICATE OF APPROVAL No CF 118 DORMA UK LTD

CERTIFICATE OF APPROVAL No CF 118 DORMA UK LTD CERTIFICATE OF APPROVAL No CF 118 1 This is to certify that, in accordance with TS00 General Requirements for Certification of Fire Protection Products The undermentioned products of Wilbury Way, Hitchin,

More information

Best practice guide. Door coordinator devices to BS EN in association with. Association of Building Hardware Manufacturers

Best practice guide. Door coordinator devices to BS EN in association with. Association of Building Hardware Manufacturers CI/SfB (32) Xt7 June 2003 Association of Building Hardware Manufacturers Best practice guide Door coordinator devices to BS EN 1158 in association with BRITISH HARDWARE FEDERATION Extracts from BS EN 1158:

More information

Fire Design Guide. Introduction Scope Aims Consultation Design Strategy Compartmentation Provision...

Fire Design Guide. Introduction Scope Aims Consultation Design Strategy Compartmentation Provision... Fire Design Guide Contents Introduction... 3 Scope... 3 Aims... 3 Consultation... 3 Design Strategy... 4 Compartmentation... 4 Provision... 4 Sub-compartmentation... 5 Doorways... 6 Penetrations... 6 Cause

More information

The Passive Fire Protection Handbook

The Passive Fire Protection Handbook The Passive Fire Protection Handbook The UK s comprehensive guide to passive fire protection Chapter 1 Introduction AUGUST 2017 The Passive Fire Protection Handbook Contents Chapter 1: Introduction2 Applications

More information

High Security Locking. Product Catalogue

High Security Locking. Product Catalogue High Security Locking Product Catalogue An ASSA ABLOY Group company 2 Adams Rite Europe Limited About the company Adams Rite was formed in 1946 in Los Angeles, California and over the years we have created

More information

White Paper. Keeping up with compliance: Escape doors standards. The global leader in door opening solutions

White Paper. Keeping up with compliance: Escape doors standards. The global leader in door opening solutions White Paper Keeping up with compliance: Escape doors standards The global leader in door opening solutions Introduction When it comes to access control, there is no greater responsibility than specifying

More information

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT NO 68 (ENGLISH AND PHILOSOPHY)

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT NO 68 (ENGLISH AND PHILOSOPHY) FIRE RISK ASSESSMENT NO 68 (ENGLISH AND PHILOSOPHY) BUILDING SUMMARY The building was constructed in Victorian times and is constructed of brick with knapped flint in fill on some outer walls. The building

More information

Practice Guidee No.1. of the

Practice Guidee No.1. of the Intumescent Fire Seals Association Good Practice Guide No. 1 The Fire Risk Assessors Good Practice Guidee No.1 Guidance to risk assessors in respect of the use of intumescent door sealss THE HOME OF REACTIVE

More information

Guide to Fire and Escape Doors: Part 1 - What are they? Produced by the Guild of Architectural Ironmongers Sponsored by Abloy UK

Guide to Fire and Escape Doors: Part 1 - What are they?  Produced by the Guild of Architectural Ironmongers Sponsored by Abloy UK Guide to Fire and Escape Doors: Part 1 - What are they? Produced by the Guild of Architectural Ironmongers Sponsored by Abloy UK www.gai.org.uk Introduction This will be a brief overview of the subject,

More information

Fire Risk Assessment

Fire Risk Assessment Fire Risk Assessment Maritime Studios Pendennis Rise Falmouth TR11 4FB Carried out by: Date: October 2015 Review Date: October 2016 Les Carter CMIOSH Health & Safety Consultant Mobile 07831 636751, Email

More information

Design Guidelines Fire Safety in New and Refurbished Buildings

Design Guidelines Fire Safety in New and Refurbished Buildings Design Guidelines Fire Safety in New and Refurbished Buildings Introduction All major new or refurbishment projects must comply with the Technical Standards (Scotland) Regulations as a matter of course.

More information

best practice guide Pedestrian doorsets Fire resisting and/or smoke control characteristics - to

best practice guide Pedestrian doorsets Fire resisting and/or smoke control characteristics - to best practice guide Pedestrian doorsets Fire resisting and/or smoke control characteristics - to BS EN 16034: 2014 Permission to reproduce extracts from BS EN 16034 : 2014 is granted by BSI. DHF BEST PRACTICE

More information

CERTIFICATE OF APPROVAL No CF 738 ALLEGION (UK) LIMITED

CERTIFICATE OF APPROVAL No CF 738 ALLEGION (UK) LIMITED CERTIFICATE OF APPROVAL No CF 738 This is to certify that, in accordance with TS00 General Requirements for Certification of Fire Protection Products The undermentioned products of 35 Rocky Lane, Aston,

More information

CERTIFICATE OF APPROVAL No CF 114 EXIDOR LIMITED

CERTIFICATE OF APPROVAL No CF 114 EXIDOR LIMITED CERTIFICATE OF APPROVAL No CF 114 1 This is to certify that, in accordance with TS00 General Requirements for Certification of Fire Protection Products The undermentioned products of Progress Drive, Cannock,

More information

THE INSTITUTE OF HEALTHCARE ENGINEERING AND ESTATE MANAGEMENT FIRE SAFETY TECHNICAL PLATFORM (FSTP) LIBRARY OF TECHNICAL GUIDANCE. No 2.

THE INSTITUTE OF HEALTHCARE ENGINEERING AND ESTATE MANAGEMENT FIRE SAFETY TECHNICAL PLATFORM (FSTP) LIBRARY OF TECHNICAL GUIDANCE. No 2. THE INSTITUTE OF HEALTHCARE ENGINEERING AND ESTATE MANAGEMENT FIRE SAFETY TECHNICAL PLATFORM (FSTP) LIBRARY OF TECHNICAL GUIDANCE No 2. FIRE DOOR PPM Introduction The FSTP has at its core, to act as the

More information

IFE Level 3 Certificate in Passive Fire Protection

IFE Level 3 Certificate in Passive Fire Protection IFE Level 3 Certificate in Passive Fire Protection Qualification Number: 603/3054/5 Introduction The IFE Level 3 Certificate in Passive Fire Protection has been developed by the Institution of Fire Engineers

More information

Technical Seminar on the Code of Practice for Fire Safety in Buildings 2011

Technical Seminar on the Code of Practice for Fire Safety in Buildings 2011 Technical Seminar on the Code of Practice for Fire Safety in Buildings 2011 The Code of Practice for Fire Safety in Buildings 2011 The FS Code comprises 7 parts and 1 annex: Part A Introduction Part B

More information

LABELING OF FIRE-RATED GLAZING STUDY GROUP REPORT TO CTC MEETING CHICAGO, IL - OCTOBER 13-14, 2011 CODE CHANGES

LABELING OF FIRE-RATED GLAZING STUDY GROUP REPORT TO CTC MEETING CHICAGO, IL - OCTOBER 13-14, 2011 CODE CHANGES LABELING OF FIRE-RATED GLAZING STUDY GROUP REPORT TO CTC MEETING CHICAGO, IL - OCTOBER 3-4, 20 CODE CHANGES Issue : Clarification of when 703.6 can be used rather than 76. 76.2 --rated glazing. --rated

More information

Loss Prevention Standard

Loss Prevention Standard Loss Prevention Standard LPS 1531: Issue 1.1 companies installing or applying passive fire protection This Loss Prevention Standard is the property of BRE Global Ltd. and is made publicly available for

More information

DOOR SETS. Versatile with a range of options, they can be tailored to suit your needs.

DOOR SETS. Versatile with a range of options, they can be tailored to suit your needs. DOOR SETS DOOR SETS Classically elegant, made with finest quality sustainable timber, our door sets give a distinctive stamp to any home. Ideal for new build housing projects and replacement of existing

More information

FIRE SAFETY LOG BOOK. (Record of Fire Safety Equipment Testing)

FIRE SAFETY LOG BOOK. (Record of Fire Safety Equipment Testing) FIRE SAFETY LOG BOOK (Record of Fire Safety Equipment Testing) Fire safety log book MARCH 2013 CONTENTS 1.0 PREMISES SPECIFIC INFORMATION 2.0 FIRE SAFETY EQUIPMENT TESTING 2.1 Escape Routes 2.2 Fire Warning

More information

CERTIFICATE OF APPROVAL No CF 252 GEZE UK LIMITED

CERTIFICATE OF APPROVAL No CF 252 GEZE UK LIMITED CERTIFICATE OF APPROVAL No CF 252 This is to certify that, in accordance with TS00 General Requirements for Certification of Fire Protection Products The undermentioned products of Blenheim Way, Fradley

More information