XMT 5000 INTELLIGENT TRANSMITTER/CONTROLLER

Size: px
Start display at page:

Download "XMT 5000 INTELLIGENT TRANSMITTER/CONTROLLER"

Transcription

1 XMT 000 INTELLIGENT TRANMITTERCTROLLER OPERATING INTRUCTI. Features and technique parameter.. Ordering number. Input type. Trouble shooting. Installation wiring... Panel display.. Operation diagram. Parameter diagram Tel:00--00, Fax:00--0,

2 . Feature and technique parameter. Feature Designed based on computer processor, it can be programmed by keys on the panel to suit any type of sensor, and there is no linear error for any sensor. Auto-zero calibration, there is no temperature drift and time drift, no need to calibrate again even two years later. All parameters are stored in an EEPROM which is safe for all case and for long time. With R or R communication port, it may communicate with computer or DC system.. Technique parameter Environment condition:temperature:0 ~ 0, relation humidity: 0% Power supply:ac0v ~ V (0 ~ 0HZ)or DC±0%V Accuracy :0.%F.±digital, dissolution:0.00,0.0,0., Input feature:tc:input impedance >0MΩ, RTD:wire resistance 0~Ω,three wires are the same Voltage input:input impedance >00kΩ, ma:input impedance 0Ω Inside cold terminal compensation temperature:0 ~ 0 Power dissipation:<w Weight<0.kg.. Environment Power supply Environment temperature Relative humidity Oscillation Outside magnetic field VDC±0% 0~0 %RH f HZ,Amplitude ±0.mm 00AM.. tructure characteristic and Installation Outside dimension:: mm Install method:: rail fixing (refer to fig ) Weigh :00g The temperature outside dimension Fig. Ordering number XMTXMB Ordering number Intelligent controller eries Electronic transformer 0 No alarm Type of control output Type of input With high or low alarm relay output With high and low alarm relay output With three limits alarm(only to MT000) With four limits alarm(only to XMT000) For thermocouple For thermo-resistor For mv sensor For 0~0Ω sensor Tel:00--00, Fax:00--0, qqmd@fcanwell.com - -

3 For 0~0mA sensor For ~0mA sensor For 0~V sensor For ~V sensor For special sensor U Omnipotence type Type of transfer output 0 No transfer output(only to XMT000) Transfer control 0 ~ 0mA ( only to XMB000) Transfer control ~0mA ( only to XMB000) Transfer control 0~V (only to XMB000) Transfer control ~V (only to XMB000) pecial transfer control ( only to XMB000) 0 0mm horizontal type Outline Power output Power supply V F V 0 0mm vertical type mm square type mm small horizontal type mm small vertical type Without power output P With V power output Power supply 0VAC D Power supply VDC(no to,v outline) Without communication port Type of Communic-ati on port R R PRN MODEM With R isolated communication port With R isolated communication port With R isolated printer port With isolated MODEM port. Input type..! Linear input and measurement range Input type Display symbol Resolu-tio n Measurement range Linearity 0μA -~ 0-0mA input Linearity 0μA -~ -0mA input uitable sensor tandard linear input Linearity mv -~ 0-V input Linearity mv -~ -V input Un-standard linear inputreference to Un-standard linear input mv -~. (>0mV) Extract 0μA -~ 0-0mA input Extract 0μA -~ -0mA input tandard linear input Extract mv -~ 0-V input Extract mv -~ -V input Un-standard square root input mv Un-standard square root input -~ (>0mV) Tel:00--00, Fax:00--0, qqmd@fcanwell.com - -

4 ! RTD input and measurement range Input type Display symbol Resolution Measurement range uitable sensor Pt00-00~00 Platinum R0=00Ω Pt ~00.0 Platinum R0=00.0Ω Pt0-00~0 Platinum R0=0Ω Cu ~0.0 Copper R0=00Ω Cu ~0.0 Copper R0=0Ω 0~0Ω 0.Ω User Pressure gauge 0-0Ω! TC input and measurement range Input type Display Resolution Measurement uitable sensor symbol range B 00~00 TC type: B R 0~0 TC type: R 0~00 TC type: N 0~00 TC type: N K 0~00 TC type: K E 0~00 TC type: E J 0~00 TC type: J T -00~00 TC type: T Un-standard mv 0.0 mv - ~ Any input within 0~ 0mV Reference to. Reference to... DIP switch sketch map horizontal type and 0 0 vertical type sketch map H H- H- H- H- H- H- H- H- Resistance H- H- H- H- Thermocouple Note:witch position and state H- H- H- H- Voltage H- H- H- H- : :OFF Current... square type sketch map Resistance Thermocouple Voltage Current Note:switch position and state : :OFF... and small type sketch map... If there is no H,please parallel connection one 0.0Ω resistance between and junctions when input is current (ma) Input ThermocoupleResistance TC RTD Current ma Voltage V JP JP H 跳线器 0mm witch sketch map sketch map H JP JP ketch map Tel:00--00, Fax:00--0, qqmd@fcanwell.com - -

5 . Trouble shooting.. Trouble shooting LED display Trouble Cause Eliminate method Not lighting Power fail Power terminal fail Device go wrong Input type wrong Input overflow Input line break Input type wrong Input overflow Calibration wrong Input type wrong Input under -range Calibration wrong Check the power Take out the device core and check the power terminal Contact to the distribute or manufacture Check the input type Check the input Check the input wire Check the input type Check input Calibration the input again Check input type Check input Calibration the input again Input type wrong Check the input type Display wrong Correction menu Check the correction menu wrong Trouble Cause Eliminate method Display wrong Input wire wrong Input wrong Check the input wire Check the input Can not enter thedevice type wrong Contact to the distribute or manufacture corresponding menu The menu be locked Unlock the menu Can t unlock the menu Display change suddenly Lose the unlock code Contact to the distribute or manufacture Ac circuit, join a resistor-capacity spark-absorbent. Influenced by the rear contactor s spark DC circuit join a reverse diode Wrong wiring Disturbance of the power eparate wire from power wire hield the wire and connect the shield to the ground on panel end. Wrong connection of the power line Check the connection of the power line The power board burned out Bad power quality Add purifying power, connect to other power Relay action wrong Influenced by the rearac circuit, join a resistor-capacity spark absorbent. contactor s spark DC circuit, join a reverse diode. Installation and wiring.. Note: ignal cable should depart from the power supply, and mast be the shield cable, and the shield mast be connected to the earth, to avoid the influence... The device power should be an independent power, a cleaning power, and should not be connected to other polluted power... XMT(0 0 0mm, 0 0 0mm)series wiring Tel:00--00, Fax:00--0, qqmd@fcanwell.com - -

6 V or ma -wire -wire VDC ignal's pulse Powersi gnals' common VDC Input wiring 0 R R ALR ALR Relay output wiring XMT000 series wiring (0mm 0mm 0mm, 0mm 0mm 0mm) RX TX DR GD B A ALR ALR 0 Power wiring Note:. Modem and PRN s wiring are the same as R s wiring. We keep the right to promote the products, if there are difference between operation instruction and case back wiring, the case back wiring is always the right... XMB(0 0 0mm, 0 0 0mm)series wiring 0VAC VDC XMB000 series wiring (0mm 0mm 0mm, 0mm 0mm 0mm) 0 R R B A RX TX DR GD V or ma -wire -wire VDC ignal's puls Power s' common VDC Input wiring ALR ALR Output wiring 0 V or ma 0VAC VDC Power wiring Note:. Modem and PRN s wiring are the same as R s wiring. We keep the right to promote the products, if there are difference between operation instruction and case back wiring, the case back wiring is always the right... XMT( 0mm) series wiring XMT000 series wiring (mm mm) ALR ALR ALR ALR V or ma Output wiring -wire -wire VDC ignal's puls Powers ignals' common VDC Input wiring RXD TXD GND A B R Communication wiring R VAC VDC Power wiring Tel:00--00, Fax:00--0, qqmd@fcanwell.com

7 Note:. Modem and PRN s wiring are the same as R s wiring. We keep the right to promote the products, if there are difference between operation instruction and case back wiring, the case back wiring is always the right... XMB( 0mm)series wiring ALR V or ma 0 XMB000 series wiring (mm mm) 0 0 ALR V OR ma Output wiring -wire -wire VDC ignal's puls Power s' common VDC Input wiring RXD TXD GND A B R Communication wiring R 0VAC 0 VDC 0 Power wiring Note:. Modem and PRN s wiring are the same as R s wiring.we keep the right to promote the products, if there are difference between operation instruction and case back wiring, the case back wiring is always the right... XMT( 0mm, 0mm) series wiring V or ma -wire -wire - - VDC ignal's puls Power s' -common - VDC XMT000 series wiring (mm mm,mm mm) 0 0 报警 ALR ALR Relay output wiring 0VAC Input wiring Power wiring Note:. Modem and PRN s wiring are the same as R s wiring.we keep the right to promote the products, if there are difference between operation instruction and case back wiring, the case back wiring is always the right. Tel:00--00, Fax:00--0, qqmd@fcanwell.com - -

8 .. XMB( 0mm, 0mm) series wiring V or ma -wire - - VDC ignal's puls Power s' -common XMB000 series wiring (mm mm,mm mm) Output wiring ALR ALR V OR ma -wire - VDC 0VAC Input wiring Power wiring Note:. Modem and PRN s wiring are the same as R s wiring.we keep the right to promote the products, if there are difference between operation instruction and case back wiring, the case back wiring is always the right.. Panel display HIGH PV LOW LOW HIGH HIGH HIGH LOW OUT V HIGH HIGH LOW LOW LOW LOW LOW HIGH HIGH PV HIGH LOW OUT HIGH V LOW Outline(mm): Panel cutoff(mm): Display KEY LED lamp Panel message Upper display When in working state, it indicates input. When in state, it indicates parameter name or parameter value. Lower display When in working state, it indicates other parameter with low display menu. When in state, it indicates parameter suggestive information. It is used to decrease parameter in state. ET It is used to confirm parameter in state. It is used to increase parameter in state. HIGH High-high alarm( )indicator HIGH High alarm( )indicator LOW Low alarm( )indicator LOW Low-low alarm( )indicator Tel:00--00, Fax:00--0, qqmd@fcanwell.com - -

9 . Operation diagram Note:Keeping no key operate 0 seconds in state, it will return to working state automatically; If some menu can not be seen, it may be locked or have not the function The symbol,, in the drawing means pressing the key,et,,the content in the pane is display message in upper and lower display. Working state Unlock uccess A.Lock operation Lock Lock class Lock password Fail B.Unlock operation uccess Unlock password Alarm value Alarm value Alarm value Alarm value Endfounction Func Alarm mode ALR blooey output state ALR hysteresis ALR delay(second) C.Alarm parameter Alarm mode ALR blooey output state ALR hysteresis ALR delay(second) Alarm mode... Lower display select... Input type ALR hysteresis Decimal ALR MODE Little flow cutoff Range zero ALR hysteresis Range full scale D.Lower display select E.Input type and range... imulation output selection imulation output blooey state select imulation imulation output output zero full scale F.imulation output ~... Communication address Old value# before correction New value# after correction Baud rate Old value# before correction New value# after correction Input filter time(sec) G.Cancel TC cold terminal compensation H.Communication parameter I.Range correction and input filter time Input zero calibration xx Input full scale calibration J.Calibration operation Room temperature calibration Output zero calibration Output full scale calibration K.End parameter Tel:00--00, Fax:00--0, qqmd@fcanwell.com - -

10 . Parameter operation A. Lock operation B. Unlock operation A. B. Entry of the lock and unlock menu group Press key Δ to exit Lock class Press key to modify etting lock password Press key to modify Input unlock password Press key to modify Parameter explain Entry of the lock and unlock menu group : Lock all menu : Lock all menu except alarm menu : Lock calibration menu only Password Note: 00 is a invalid password Unlock password C. Alarm parameter Entry of alarm menu group Press key to exit Alarm alarm value Press key to modify Alarm alarm value Press key to modify Alarm alarm value Press key to modify Alarm alarm value Press key to modify Alarm select Press key to modify Alarm mode Press key to modify Alarm blooey output state Press key to modify Alarm hysteresis Press key to modify Alarm delay Press key to modify Alarm mode Press key to modify 0%*F 0%F 0%*F 0%*F 0 or 0. or 0.0 Entry of alarm menu group ALR value ALR value ALR value (Point out when ordering) ALR value (Point out when ordering) :End alarm :Enter advanced Alarm mode :low alarm :high alarm Alarm blooey output state :alarm action : alarm unchain : alarm keep Alarm hysteresis 00 秒 Alarm delay ALR mode :low alarm :high alarm Tel:00--00, Fax:00--0, qqmd@fcanwell.com

11 Alarm blooey output state Press key to modify Alarm hysteresis Press key to modify Alarm delay Press key to modify D. Lower display content E. Input type and range Alarm mode Press key to modify Alarm hysteresis Press key to modify Alarm mode Press key to modify Alarm hysteresis Press key to modify Entry of the lower display menu group Press key to exit Lower display content Press key to modify Entry of the range menu group Press key to exit Input type Press key to modify Input decimal position Press key to modify Little flow cutoff Press key to modify Range zero Press key to modify Range full scale Press key to modify 0 or 0. or 0.0 :alarm action : alarm unchain : alarm keep ALR hysteresis 00 second Alarm delay 0 or 0. or or 0. or 0.0 As ordering As ordering 00 As ordering As ordering Alarm mode :low alarm :high alarm Alarm hysteresis Alarm mode :low alarm :high alarm Alarm hysteresis Entry of the lower display menu : Alarm value : Alarm value : Alarm value : Alarm value :imulation output :Room temperature Entry of input type and range Reference to input type selection Decimal position Little flow cutoff (Engineering units) Range zero Range full scale Tel:00--00, Fax:00--0, qqmd@fcanwell.com

12 F.imulation output Entry of simulation output menu Press key to exit Output mode selection menu Press key to modify Output blooey state selection menu Press key to modify Output zero Press key to modify Output full scale Press key to modify As ordering As ordering As ordering Entry of simulation output :0-0mA output :-0mA output :0-v output :-v output :other output Output blooey state: :full scale output :zero output :keep output Output zero (the same as ) Output full scale (the same as ) G. Cancel TC cold terminal compensation Cancel TC cold terminal compensation Press key to exit Note: Cold terminal temperature compensation function will be recovered,if the meter s power is turned off and turned on again. H. Communication ~ Entry of the communication menu group Press key to exit Communication address Press key to modify Communication baud rate Press key to modify Turn on the power again, the TC cold terminal compensation will be recovered Compensation range: 0~0 Parameter explain Communication address: 0~ :00bps; :00bps; :00bps; :00bps I. Error correction Entry of error correction menu group Press key to exit Parameter explain Entry of error correction menu group Old value# before correction Press key to modify New value# after correction Press key to modify 00 or 0.0 or 0.00 or or 0.0 or 0.00 or Old value# before correction New value# after correction Tel:00--00, Fax:00--0, qqmd@fcanwell.com

13 Old value# before correction Press key to modify New value# after correction Press key to modify 000 or 00.0 or 0.00 or or 00.0 or 0.00 or.000 Old value# before correction New value# after correction Filter time Press key to modify 0 second Filter time: - If the input sensor is an standard sensor, please do not change the factory of the correction menu. If there is display error exist, you can correct the error with correction menu, but need not to calibrate the device again. If the input is a special, you may regard it a standard input that it s measurement range is first, then get the true measurement range with correction menu. And need not to calibrate the device with the true zero and full range. It is very convenient. Be caution: The correction value # and correction value # mast be far away, and can not be the same value, or else the device will go wrong. J. Calibration operation Entry of the calibration menu group Entry of the calibration menu Press key to exit group Exit the calibration operation Exit the calibration operation Press key to exit Entry of input calibration menu Press key to exit Input zero calibration Input a zero to the input terminal, keep steady for 0 seconds, press key ET to confirm 0~0mA~0mA zero is 0.000mA 0~V~V zero is 0.000V Input zero calibration RTD zero is 00.00Ω TC zero is 0.000mV Other input zero is actual zero Input full scale calibration Input a full scale to the input terminal, keep steady for 0 secobds, press key ET to confirm 0~0mA~0mA full scale is 0.00mA Input full scale calibration 0~V~V full scale is.000v RTD full scale is 0.000Ω TC full scale is 0.000mV Entry of the room temperature calibration Press key to exit Room temperature calibration menu Press key to input room temperature ( ) Room temperature Entry of the output calibration menu Press key to exit Output zero calibration menu Press key to modify Output zero calibration 0~0mA~0mA zero is.00ma 0~V~V zero is.000v Output full scale calibration menu Press key to modify 0~0mA~0mA zero is 0.00mA 0~V~V zero is.000v Output full scale calibration Tel:00--00, Fax:00--0, qqmd@fcanwell.com

14 K.End operation End parameter operation Press key to exit End parameter operation Tel:00--00, Fax:00--0,

Series Digital Controller Instruction Sheet

Series Digital Controller Instruction Sheet 216/3/11 Series Digital Controller Instruction Sheet Thank you very much for purchasing DELTA DTC Series Temperature Controller. Please read this instruction sheet before using your DTC series to ensure

More information

02/11/2015

02/11/2015 CTH 46 - CTD 43 / 46 CTD 46 Part number 89422108 CTH 46 Heating / cooling function Measurement and setpoint display CTD 43 Heating or cooling function Measurement display Measurement deviation display-setpoint

More information

PMD-MXT -XX -XXX. Ordering Example. Model Input Channels Input Type. THC Thermocouple channels channels channels RTD RTD

PMD-MXT -XX -XXX. Ordering Example. Model Input Channels Input Type. THC Thermocouple channels channels channels RTD RTD Instruc on Manual Mul Lite Digital Temperature Scanner Indicator PMD-MXT Series Page 1 of 13 Part Number Configurator: Model Input Channels Input Type PMD-MXT -XX -XXX 08 8 channels RTD RTD 16 16 channels

More information

NOVUS AUTOMATION 1/5. Range: -35 to 720 C (-31 to 1328 F) Range: -90 to 1300 C (-130 to 2372 F) Range: 0 to 1760 C (-32 to 3200 F)

NOVUS AUTOMATION 1/5. Range: -35 to 720 C (-31 to 1328 F) Range: -90 to 1300 C (-130 to 2372 F) Range: 0 to 1760 C (-32 to 3200 F) E N R S B Pt100 Pt100 Range: -35 to 720 C (-31 to 1328 F) Range: -90 to 1300 C (-130 to 2372 F) Range: 0 to 1760 C (-32 to 3200 F) Range: 0 to 1760 C (-32 to 3200 F) Range: 150 to 1820 C (302 to 3308 F)

More information

02/11/2015

02/11/2015 MIC48 With RS 485 link Part number 89422418 Heating and / or cooling function 2 independent alarms Load break detection 2 setpoint which can be selected remotely Manual / automatic power adjustment RS

More information

F4 Process Controller Installation and Operation Guide

F4 Process Controller Installation and Operation Guide F4 Process Controller Installation and Operation Guide 1.Introduction 1.1.Highlight Features Space saving, only 55mm panel depth required Higher sampling rate (1mS) results in better control performance

More information

Installation Manual Tracker 221

Installation Manual Tracker 221 Installation Manual Tracker 221 KSR KUEBLER AG Im Kohlstatterfeld 17 D-69439 Zwingenberg / Germany www.ksr-kuebler.com Contents About this Installation Manual...4 Description Tracker 220-series...4 Installing

More information

UDC 700 Universal Digital Controllers and Indicator Specifications

UDC 700 Universal Digital Controllers and Indicator Specifications UDC 700 Universal Digital Controllers and Indicator Specifications 51-52-03-28 August 2002 Overview The UDC 700 is a 1/32 DIN (49 x 25 mm) controller which combines a high degree of technology and quality

More information

CN-6000 Series. Features. Ordering information CN C1. Part descriptions. 5 ( key: Used to enter parameter set mode, move to parameters,

CN-6000 Series. Features. Ordering information CN C1. Part descriptions. 5 ( key: Used to enter parameter set mode, move to parameters, CN-6000 eries Features Multi-input CN-610 : Thermocouple 12 types, RTD 5 types, Analog (mv, V, ma) 6 types CN-640 : 0 to 50.00kHz Improves visibility with negative LCD : 12 segment, 3 colors (selectable

More information

3500/61E & 3500/67E Temperature Monitor

3500/61E & 3500/67E Temperature Monitor 3500/61E & 3500/67E Temperature Monitor Bently Nevada* Asset Condition Monitoring Description The 3500/61E and 3500/67E modules provide six channels and two channel of temperature monitoring. Both monitors

More information

CN-6000 Series. Features. Ordering information CN C1. Part descriptions. 5 ( key: Used to enter parameter set mode, move to parameters,

CN-6000 Series. Features. Ordering information CN C1. Part descriptions. 5 ( key: Used to enter parameter set mode, move to parameters, CN-6000 eries Features Multi-input CN-610 : Thermocouple 12 types, RTD 5 types, Analog (mv, V, ma) 6 types CN-640 : 0 to 50.00 khz Improves visibility with negative LCD : 12 segment, 3 colors (selectable

More information

Universal controller for panel mounting Models CS6S, CS6H, CS6L

Universal controller for panel mounting Models CS6S, CS6H, CS6L Accessories Universal controller for panel mounting Models CS6S, CS6H, CS6L WIKA data sheet AC 85.08 Applications Plant and industrial furnace construction Process engineering Plastics technology and processing

More information

AutomationDirect PM24. Microprocessor - Based Process/Temperature Limit Controller. Operator s Manual. Technical Support.

AutomationDirect PM24. Microprocessor - Based Process/Temperature Limit Controller. Operator s Manual. Technical Support. AutomationDirect 1/16 DIN Series Technical Support We strive to make our manuals the best in the industry. We rely on your feedback to let us know if we are reaching our goal. If you cannot find the solution

More information

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements Specifications COMMANDER 150 Universal Process Indicator High visibility 6-digit LED display the clearest view of your process status 0.1% measurement accuracy precise indication of process measurement

More information

COMMANDER 150. User Guide Universal Process Indicator A1

COMMANDER 150. User Guide Universal Process Indicator A1 COMMANDER 150 User Guide Universal Process Indicator COMMANDER 150 888888A1 A2 A3 Use of Instructions Warning. An instruction that draws attention to the risk of injury or death. Caution. An instruction

More information

DIGITAL METERS Large Display Temperature Meters Instruction Manual

DIGITAL METERS Large Display Temperature Meters Instruction Manual DIGITAL METERS Large Display Temperature Meters PD755 PD756 PD757 Handles Thermocouple & RTD Inputs with Simplicity J, K, T, E, R, & S Thermocouples 100 Ω Platinum RTD (0.00385 or 0.00392 curve) Large

More information

Table of Contents SECTION PAGE SECTION 1 INTRODUCTION Description Features Models... SECTION 2 RS-232 COMMUNICATIONS...

Table of Contents SECTION PAGE SECTION 1 INTRODUCTION Description Features Models... SECTION 2 RS-232 COMMUNICATIONS... SECTION Table of Contents SECTION 1 INTRODUCTION...................... 1.1 Description............................... 1.2 Features................................. 1.3 Models..................................

More information

User's Manual. Model VJQ8 Pulse to Analog Converter. (Multi-function) MODEL AND SUFFIX CODES CAUTIONARY NOTES FOR SAFE USE OF THE PRODUCT

User's Manual. Model VJQ8 Pulse to Analog Converter. (Multi-function) MODEL AND SUFFIX CODES CAUTIONARY NOTES FOR SAFE USE OF THE PRODUCT User's Manual Model VJQ8 Pulse to Analog Converter (Multi-function) (Isolated Single-output and Isolated Dualoutput Types) Thank you for purchasing the JUXTA Signal Conditioner. Please read through this

More information

Important Supplementary Manual to the main Ezeio manual. 5. Section 2a: Introducing the 2400 input and output expansion field stations.

Important Supplementary Manual to the main Ezeio manual. 5. Section 2a: Introducing the 2400 input and output expansion field stations. 1 P age Ezeio v9-120317 Eze Cloud Based Monitoring Systems. Created by Intech Instruments Ltd December 2014 Important Supplementary Manual to the main Ezeio manual. Ezeio Controller and the 2400-A16 input

More information

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS NOVA PD56 Series Thermocouple, RTD, & Process Inputs Universal Power Supply 1-24 VAC Up to 3 Alarm Relays Retransmitting 4-2 ma Output Input Max/Min

More information

Serie Rugghölzli 2 CH Busslingen. Tel. +41 (0) Fax +41 (0)

Serie Rugghölzli 2 CH Busslingen. Tel. +41 (0) Fax +41 (0) Serie 5000 Tel. +1 (0)5 222 Fax +1 (0)5 222 12 PRODUCT INTRODUCTI PRODUCT INTRODUCTI 5 Series programmable temperature controller is FineTek's mid-range series of controllers. It uses a 12bit analog /

More information

Process & TeMPerATUre UniversAl input DigiTAl MeTers

Process & TeMPerATUre UniversAl input DigiTAl MeTers Process & TeMPerATUre UniversAl input DigiTAl MeTers nova PD56 series Thermocouple, rtd, & Process inputs Universal Power supply 1-24 va c Up to 3 Alarm relays retransmitting 4-2 ma output input Max/Min

More information

Series Temperature Controller Instruction Sheet

Series Temperature Controller Instruction Sheet Series Temperature Controller Instruction Sheet Thank you very much for purchasing DELTA A Series. Please read this instruction sheet before using your A series to ensure proper operation and please keep

More information

General Specifications

General Specifications General Specifications GS J0H-0E Model MVHK Digital Limit Alarm (DC Type) with Active Color PV Display General This plug-in type Digital Limit Alarm for DC input receives DC current or DC voltage signal.

More information

I/A Series 716C 1/16 DIN Temperature Controller

I/A Series 716C 1/16 DIN Temperature Controller Product Specifications I/A Series 716C 1/16 DIN Temperature Controller PSS 2C-1B5 A The Foxboro 716C is a powerful compact, 1/16 DIN, microprocessor-based temperature controller that offers a variety of

More information

Analog Room Pressure Monitor RPC Series

Analog Room Pressure Monitor RPC Series Description The Room Pressure Monitor is used to measure differential pressure in the range of 0.125 to 1"wc or 30 to 250 Pa. It combines precision high sensitivity silicon sensing capabilities and the

More information

Temperature Controllers

Temperature Controllers Model TEC-4100 1/4 DIN Model TEC-4100 1/4 DIN Temperature Controller Ordering Code: Power Input BOX 1 4 = 90-250 VAC 5 = 11-26 VAC / VDC TEC-4100- Configurable for 4 Programmable Outputs and NEMA 4X/IP65

More information

OVEN INDUSTRIES, INC.

OVEN INDUSTRIES, INC. OVEN INDUSTRIES, INC. OPERATING MANUAL Model 5C7-252 TEMPERATURE CONTROLLER With PLC Inputs Introduction Thank you for purchasing our controller. The Model 5C7-252 is an exceptionally versatile unit and

More information

VT4810 SINGLE / DUAL ZONE CONTROLLER INSTALLATION MANUAL

VT4810 SINGLE / DUAL ZONE CONTROLLER INSTALLATION MANUAL Thermocouple Type BS4937 (IEC584-3): Outer / + / - BS1843 (Old UK Standard) Outer / + / - US Outer / + / - J : Iron / Copper-Nickel Black / Black / White Black / Yellow / Blue Black / White / Red VT4810

More information

MYRIAD TRIPLEX PUMP CONTROLLER INSTRUCTION MANUAL

MYRIAD TRIPLEX PUMP CONTROLLER INSTRUCTION MANUAL MYRIAD TRIPLEX PUMP CONTROLLER INSTRUCTION MANUAL MYRIAD TPC VISIT OUR WEBSITE SIGMACONTROLS.COM MYRIADI&O062705 2 TABLE OF CONTENTS INTRODUCTION 3 Ordering Information Specifications Features WIRING 7,8

More information

eed quality electronic design USER s MANUAL

eed quality electronic design USER s MANUAL eed quality electronic design www.dem-it.com eed www.qeed.it info@qeed.it ANALOG SIGNAL DISPLAY Q-DISP-T USER s MANUAL The displays Q-DISP-T, prepared for mounting on the back panel, 96x48mm, will allow

More information

Tempco Part Number PCT30006 Temperature Control Enclosure with Relay Output for Tote Tank Heating Applications

Tempco Part Number PCT30006 Temperature Control Enclosure with Relay Output for Tote Tank Heating Applications Instruction Manual Tempco Part Number PCT30006 Temperature Control Enclosure with Relay Output for Tote Tank Heating Applications Manual PCT30006, Revision 9/20/2016 The PCT30006 control enclosure incorporates

More information

VERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER

VERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER 1 VERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER 1. INTRODUCTION This manual contains information for the installation and operation and tuning of our Vertex VT10 series self-tuning

More information

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009 STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009 Introduction Honeywell s STT 3000 family of microprocessor based transmitters covers the full

More information

Tempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications

Tempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications Instruction Manual Tempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications Manual PCT-3000 Revision 9/2014 The PCT-3000 series control console incorporates

More information

MICRO CONTROLLER S Z SERIES

MICRO CONTROLLER S Z SERIES Instruction Manual MICRO CONTROLLER S Z SERIES TYPE: PYW 4 5 7 9 Fuji Electric Co.,Ltd. INP-TN1PYWf-E INTRODUCTION You are now the owner of Fuji's digital Temperature Controller. Before using, be sure

More information

/8 DIN Universal Process Indicator

/8 DIN Universal Process Indicator User Guide IM/C150_13 1 /8 DIN Universal Process Indicator C150 Electrical Safety This equipment complies with the requirements of BS EN 61010-1:2001-2 "Safety Requirements for Electrical Equipment for

More information

N1540 Process Indicator

N1540 Process Indicator N1540 Process Indicator UNIVERSAL INDICATOR INSTRUCTIONS MANUAL V2.0x PRESENTATION N1540 is a quite versatile process indicator. With a wide list of input types - thermocouples, thermo-resistance, voltage

More information

INSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER JCD-13A, JCR-13A

INSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER JCD-13A, JCR-13A INSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER JCD-13A, JCR-13A Preface Thank you for the purchase of our Microcomputer based Temperature Indicating Controllers JCD-13A or

More information

MICROJET RECORDER (24-CHANNEL 180mm)

MICROJET RECORDER (24-CHANNEL 180mm) MICROJET RECORDER (24-CHANNEL 180mm) DATA SHEET PHB This recorder can record a maximum of 24 channels of DC voltage, ma, thermocouples and resistance bulbs. The adoption of an ink jet system makes it possible

More information

DIGITAL INDICATOR DI25

DIGITAL INDICATOR DI25 DIGITAL INDICATOR DI25 Operating instructions Preface Thank you for purchasing our digital indicator DI25. This manual contains instructions for the mounting, functions, operations and notes when operating

More information

Advanced Test Equipment Rentals ATEC (2832)

Advanced Test Equipment Rentals ATEC (2832) Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) FEATURES AND SPECIFICATIONS MOLYTEK 2702 AND 3702 RECORDERS 2702 3702 REV: 03302004 Standard Specifications for Model

More information

RTA421. Technical Information. Limit alarm switch Alarm switch and power supply for monitoring current or voltage signals

RTA421. Technical Information. Limit alarm switch Alarm switch and power supply for monitoring current or voltage signals Technical Information RTA421 Limit alarm switch Alarm switch and power supply for monitoring current or voltage signals Application Plant and machine construction Panel builders Process monitoring Process

More information

DIGITAL INDICATOR JIR-301-M

DIGITAL INDICATOR JIR-301-M DIGITAL INDICATOR JIR-301-M Instruction Manual Preface Thank you for purchasing our digital indicator JIR-301-M. This manual contains instructions for the mounting, functions, operations and notes when

More information

DE20 INSTRUCTION MANUAL

DE20 INSTRUCTION MANUAL DE20 INSTRUCTION MANUAL Now UL Listed! SET POINT DE20 SET YOUR DISTRIBUTOR: Chemical Distributors, Inc. 80 Metcalfe Street - Buffalo, NY 14206 Phone: 800-777-2436 716-856-2300 Fax: 716-856-7115 sales@cdibuffalo.com

More information

User s Manual. Model VJRK IM 77J01R21-01E 1. CAUTIONARY NOTES FOR SAFE USE OF THE PRODUCT 4. MODEL AND SUFFIX CODES 5.

User s Manual. Model VJRK IM 77J01R21-01E 1. CAUTIONARY NOTES FOR SAFE USE OF THE PRODUCT 4. MODEL AND SUFFIX CODES 5. User s Manual Model VJRK Limit Alarm (RTD for RTD Input Input Type) IM J01R21-01E 1. CAUTIONARY NOTES FOR SAFE USE OF THE PRODUCT This user s manual should be carefully read before installing and operating

More information

7EF/7HF/7EC/7ES Temperature Controllers

7EF/7HF/7EC/7ES Temperature Controllers 7EF/7HF/7E/7ES Temperature ontrollers Dual 4 Digit LED Display Universal Input (6 T/, RTD, mv, V, ma) Autotuning NEMA 4X 100 to 240 Vac Switching Power Supply Algorithms for Heat or Heat/ool ontrol 2 Independent

More information

Oxygen / Carbon Dioxide Analyser / Transmitter. Model 1637

Oxygen / Carbon Dioxide Analyser / Transmitter. Model 1637 Oxygen / Carbon Dioxide Analyser / Transmitter Model August 00 Page August 00 Analyser Getting Going Fast How to get your analyser working for you with the minimum of fuss... Plug the power lead into the

More information

AIR MONITOR & ALARM SYSTEM Installation and Operating Guidelines Version 7.2 Series Software

AIR MONITOR & ALARM SYSTEM Installation and Operating Guidelines Version 7.2 Series Software AIR MOITOR & ALARM YTEM Installation and Operating Guidelines Version 7.2 eries oftware The Air monitor and Alarm ystem is a precision electronic instrument and while designed and built to withstand normal

More information

UDC100 Universal Digital Controller Specifications

UDC100 Universal Digital Controller Specifications UDC100 Universal Digital Controller Specifications 51-52-03-29 November 1999 Overview The UDC100 Universal Digital Controller is a microprocessor-based 1/4 DIN low cost temperature controller. It combines

More information

AutomationDirect. PC35 Configuration Sheet

AutomationDirect. PC35 Configuration Sheet Part#: Project: AutomationDirect PC35 Configuration Sheet Name: Date: Main Setpoint (): Cycle 5 INPUT DEFAULT CODE/VALUE Type 1 Dppo OFF Unit [ Offs 0 Spll -150 Spkl 1370 Rsll -150 Rskl 1370 Cycle 6 I/O

More information

RS485 MODBUS Module 8AI

RS485 MODBUS Module 8AI Version 1.4 15/04/2013 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained in this manual have

More information

SYL-1512A PID TEMPEARATURE CONTROLLER INSTRUCTION MANUAL Version 2.1

SYL-1512A PID TEMPEARATURE CONTROLLER INSTRUCTION MANUAL Version 2.1 SYL-1512A PID TEMPEARATURE CONTROLLER INSTRUCTION MANUAL Version 2.1 Jun. 2007 Auber Instruments, 730 Culworth, Alpharetta, GA 30022 www.auberins.com e-mail: auberins@gmail.com Tel: 404-291-6298 WARNING

More information

FAHM Co. Temperature Transmitter PTT74 Series

FAHM Co. Temperature Transmitter PTT74 Series FAHM Co. PTT74 Series The PTT74 is a versatile temperature transmitter that delivers field reliability and advanced accuracy and stability to meet demanding process needs. PTT74 Family of Transmitters

More information

Process Alarm Module RTA 421

Process Alarm Module RTA 421 Technical Information TI 074R/24/ae Process Alarm Module RTA 421 Alarm module and power supply for monitoring current or voltage signals Application Areas Plant and machine construction Panel builders

More information

isopv425 and AGH420 Ground Fault Detector for Ungrounded Solar Arrays < 100 kw And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

isopv425 and AGH420 Ground Fault Detector for Ungrounded Solar Arrays < 100 kw And Isolation Tester Prior to Array Startup (Grounded and Ungrounded) T M 1 isopv425 and AGH420 Ground Fault Detector for Ungrounded Solar Arrays < 100 kw And Isolation Tester Prior to Array Startup (Grounded and Ungrounded) Technical Bulletin NAE1012670 / 08.2013 isopv425

More information

Temperature Controller

Temperature Controller E5AN Temperature Controller Temperature Controller OMRON Corporation Industrial Automation Company Industrial Devices and Components Division H.Q. Measuring Components Department Shiokoji Horikawa, Shimogyo-ku,

More information

TEMPERATURE CONTROL MODULE MODEL R3-TC2

TEMPERATURE CONTROL MODULE MODEL R3-TC2 INSTRUCTION MANUAL R3-TC2 TEMPERATURE CONTROL MODULE MODEL R3-TC2 CONTENTS BEFORE USE... 2 POINTS OF CAUTION... 2 COMPONENT IDENTIFICATION... 2 INSTALLATION... 2 EXTERNAL DIMENSIONS unit: mm (inch)...

More information

Indicator N1500 UNIVERSAL PROCESS INDICATOR INSTRUCTIONS MANUAL V2.3 A SAFETY SUMMARY PRESENTATION TECHNICAL ASSISTANCE

Indicator N1500 UNIVERSAL PROCESS INDICATOR INSTRUCTIONS MANUAL V2.3 A SAFETY SUMMARY PRESENTATION TECHNICAL ASSISTANCE UNIVERSAL PROCESS INDICATOR INSTRUCTIONS MANUAL V2.3 A SAFETY SUMMARY The symbols below are used on the equipment and throughout this document to draw the user s attention to important operational and

More information

99 Washington Street Melrose, MA Phone Toll Free Visit us at

99 Washington Street Melrose, MA Phone Toll Free Visit us at 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Back to the Extech 48VTR Product Info Page Instruction Manual English / Español

More information

Remote NAC Power Supply D7038

Remote NAC Power Supply D7038 Operation and Installation Guide Remote NAC Power Supply D7038 D7038 REMOTE NAC POWER SUPPLY Page 2 2005 Bosch Security Systems Contents Contents 1.0 Overview...5 1.1 Module Control...5 1.1.1 Option Bus

More information

Programmable Output Dual Relay Quad Relay. (Trip Points, High Alarm, Low Alarm, Failsafe, Non-Failsafe, Normally Open, Normally Closed)

Programmable Output Dual Relay Quad Relay. (Trip Points, High Alarm, Low Alarm, Failsafe, Non-Failsafe, Normally Open, Normally Closed) June 2004 Description The universal SPA 2 Programmable Limit Alarm Trips provide on/off control, warn of unwanted process conditions, alarm on rate-of-change and provide emergency shutdown. Very versatile,

More information

4/8/12/16 Channel Temperature Scanner with FREE Data Logging PC Software RS485

4/8/12/16 Channel Temperature Scanner with FREE Data Logging PC Software RS485 Select Option Device Wise Device/Group HumiLog Y-Axis Text Show/Hide Ledgends MIN MAX Scale Y Max 08-05-2015 15:17:59 PV_C PV_RH Color default default Graph Refresh Interval 2 Set Interval PV Low Alarm

More information

INSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER GCD-200, GCR-200

INSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER GCD-200, GCR-200 INSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER GCD-200, GCR-200 PV PV AT AT OUT1 OUT2/HB A1 A2 OUT1 OUT2/HB A1 A2 MODE OUT MODE OUT GCD GCR Preface Thank you for the purchase

More information

DIGITAL PANEL METER N20 type

DIGITAL PANEL METER N20 type DIGITAL PANEL METER N20 type USER S MANUAL 1 2 Contents 1. APPLICATION AND METER DESIGN... 5 2. METER SET... 6 3. BASIC REQUIREMENTS, OPERATIONAL SAFETY... 6 4. INSTALLATION... 7 5. SERVICE... 9 6. ERROR

More information

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features. CONsOlIDATOR 4 & 8 MulTI- C h ANNEl CONTROllERs ConsoliDator 4 Model PD940 ConsoliDator 4 Features Four 4-20 Four 4-20 Outputs ConsoliDator 8 Features Eight 4-20 Two 4-20 Outputs Common Features Four Pulse

More information

Indicator N1500 UNIVERSAL PROCESS INDICATOR INSTRUCTIONS MANUAL V2.3 C SAFETY SUMMARY PRESENTATION TECHNICAL ASSISTANCE

Indicator N1500 UNIVERSAL PROCESS INDICATOR INSTRUCTIONS MANUAL V2.3 C SAFETY SUMMARY PRESENTATION TECHNICAL ASSISTANCE UNIVERSAL PROCESS INDICATOR INSTRUCTIONS MANUAL V2.3 C SAFETY SUMMARY The symbols below are used on the equipment and throughout this document to draw the user s attention to important operational and

More information

SCHMIDT LED Measured Value Display MD Instructions for Use

SCHMIDT LED Measured Value Display MD Instructions for Use SCHMIDT LED Measured Value Display MD 10.010 Instructions for Use Table of Contents 1 Important Information... 3 2 Application range... 4 3 Mounting instructions... 4 4 Electrical connection... 6 5 Signalizations...

More information

Digital Temperature Calibrator - Thermometer MODEL 840A, 845, 850, 855

Digital Temperature Calibrator - Thermometer MODEL 840A, 845, 850, 855 840A, 845, 850, 855 Digital Temperature Calibrator - Thermometer MODEL 840A, 845, 850, 855 This owner s manual was as current as possible when this product was manufactured. However, products are constantly

More information

Safety Temperature Limiter STL 50 Certified to DIN EN (replaces DIN 3440)

Safety Temperature Limiter STL 50 Certified to DIN EN (replaces DIN 3440) Safety Temperature Limiter STL 50 Certified to DIN EN 14597 (replaces DIN 3440) Features M For use as: STB Protection - temperature limiter ASTB Exhaust gas - protection - temperature limiter STW Protection

More information

User manual. KNXgal. version

User manual. KNXgal. version User manual version 1.3 gal Management alarm control panels Galaxy from bus powered from bus Communication indication on and with Galaxy control panel DIN rail mount (1 modul) Adjustable address on with

More information

DPR-145 TEMPERATURE PROTECTION RELAY. DPR-145 User Manual V-2.0 ( ) PT100 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT VDC SUPPLY -1-

DPR-145 TEMPERATURE PROTECTION RELAY. DPR-145 User Manual V-2.0 ( ) PT100 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT VDC SUPPLY -1- DPR-45 User Manual V-2.0 (2..206) DPR-45 TEMPERATURE PROTECTION RELAY PT00 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT 9-50VDC SUPPLY DESCRIPTION DPR-45 is a precision unit designed for the temperature

More information

MICROJET RECORDER (180mm)

MICROJET RECORDER (180mm) MICROJET RECORDER (180mm) DATA SHEET PHA This recorder can record a maximum of 12 channels of DC voltage, ma, thermocouples and resistance bulbs. The adoption of an ink jet system makes it possible to

More information

SA100. General Description. Features. Temperature Controller SA100. Corresponding to Various Applications. Simple Mounting on DIN Rail

SA100. General Description. Features. Temperature Controller SA100. Corresponding to Various Applications. Simple Mounting on DIN Rail Temperature Controller General Description The is a socket mounting type temperature controller and is available for mounting inside the panel or by easily mounting on DI rail. The has features such as

More information

TAIE. Features. FY600 (96mm X 48mm) Application:Control temperature,humidity, FY Series Digital PID Controller

TAIE. Features. FY600 (96mm X 48mm) Application:Control temperature,humidity, FY Series Digital PID Controller TAIE FY Series Digital PID Controller FY600 (96mm X 48mm) Application:Control temperature,humidity, FY series controllers are microprocessor based controllers. Which have been Designed with high accuracy

More information

IM 77J01A07-01E 1st Edition Nov th Edition Feb Fixed code 0 Always 0. Output-2 signal

IM 77J01A07-01E 1st Edition Nov th Edition Feb Fixed code 0 Always 0. Output-2 signal User s Manual Model VJA Distributor (Multi-function) (Isolated Single-output and Isolated Dual-output Types) --3, Naka-cho Musashino-shi, Tokyo 180-80 Japan Thank you for purchasing the JUXTA Signal Conditioner.

More information

Communications None RS-232C RS-422* RS-485* BCD Transmission output*/** (4 to 20 ma) E5AX- E5AX- L(M)A02 L(M)A03

Communications None RS-232C RS-422* RS-485* BCD Transmission output*/** (4 to 20 ma) E5AX- E5AX- L(M)A02 L(M)A03 Digital Controller A 96 x 96-mm (DIN) Digital Process Controller Optimum PID control with feed-forward control circuitry. High accuracy (+0.3% FS +1 digit max.). Replaceable Output Units. Models with communications

More information

User s Guide CN616A. Universal 6 Channel ¼ DIN Process Controller. Shop online at omega.com

User s Guide CN616A. Universal 6 Channel ¼ DIN Process Controller. Shop online at omega.com TM User s Guide Shop online at omega.com e-mail: info@omega.com For latest product manuals: www.omegamanual.info CN616A Universal 6 Channel ¼ DIN Process Controller omega.com info@omega.com U.S.A. Headquarters:

More information

DSGH. Radiation-Based Detector with GEN2000 Electronics for Density Measurement QUICK REFERENCE GUIDE

DSGH. Radiation-Based Detector with GEN2000 Electronics for Density Measurement QUICK REFERENCE GUIDE DSGH Radiation-Based Detector with GEN2000 Electronics for Density Measurement QUICK REFERENCE GUIDE Revision History Revision History Version of manual Description Date 1.0 Initial release 051025 1.1

More information

AL3000 SERIES 100MM CHART MULTI-POINT TYPE HYBRID RECORDER

AL3000 SERIES 100MM CHART MULTI-POINT TYPE HYBRID RECORDER AL3000 SERIES 100MM CHART MULTI-POINT TYPE HYBRID RECORDER MODEL AL3 7 5 - AL3000 series conforming to CE, UL and CSA are 100mm multi-point type hybrid recorders with a simultaneous display of multi-channel

More information

TECHNICAL MANUAL CVM 3000 C 5030 CV/04-99 GB

TECHNICAL MANUAL CVM 3000 C 5030 CV/04-99 GB Summary 1 CONNECTIONS... 8 1.1 TEMPERATURE PROBES...8 1.2 PRESSURE PROBES...9 1.3 LOW VOLTAGE DIGITAL INPUTS...10 1.4 LIVE DIGITAL INPUTS...11 1.5 RELAY OUTPUTS...12 2 VOLTAGE/FREQUENCY INPUT...13 3 POWER

More information

Instruction manual for DIN rail mounting type indicating controller DCL-33A

Instruction manual for DIN rail mounting type indicating controller DCL-33A Instruction manual for DIN rail mounting type indicating controller DCL-33A To prevent accidents arising from the misuse of this controller, please ensure the operator using it receives this manual. Caution

More information

CMT MANUAL 6. NMC SENSORS

CMT MANUAL 6. NMC SENSORS CMT MANUAL 6. NMC SENSORS TABLE OF CONTENTS INDEMNITY... 5 DOCUMENT INFORMATION... 5 ACKNOWLEDGEMENTS... 5 6.1 INTRODUCTION... 6 6.2 TEMPERATURE AND HUMIDITY SENSORS... 7 6.2.1. TEMPERATURE SENSOR... 7

More information

INSTRUCTION MANUAL Micro-computer based digital indicating controller

INSTRUCTION MANUAL Micro-computer based digital indicating controller INSTRUCTI MANUAL Micro-computer based digital indicating controller TP4A To prevent accidents arising from the misuse of this controller, please ensure the operator using it receives this manual. Caution

More information

Stratomaster Smart Single

Stratomaster Smart Single Stratomaster Smart Single TC-1 One to Four channel thermocouple temperature display unit The TC-1 thermocouple temperature display unit is a 2.25 instrument that can be configured to perform the functions

More information

User Guide. DATUM L150 Panel-Mounted Universal Level Indicator A1. ABB Instrumentation

User Guide. DATUM L150 Panel-Mounted Universal Level Indicator A1. ABB Instrumentation User Guide DATUM L150 Panel-Mounted Universal Level Indicator DATUM L150 2145.3A1 A2 A3 ABB Instrumentation Use of Instructions Warning. An instruction that draws attention to the risk of injury or death.

More information

User Guide IM/C160_8. Wall-/Pipe-mounted Universal Process Indicator C160

User Guide IM/C160_8. Wall-/Pipe-mounted Universal Process Indicator C160 User Guide IM/C160_8 Wall-/Pipe-mounted Universal Process Indicator C160 Electrical Safety This equipment complies with the requirements of CEI/IEC 61010-1:2001-2 "Safety requirements for electrical equipment

More information

Scanning Laser Range Finder Smart-URG mini UST-10LN Specification

Scanning Laser Range Finder Smart-URG mini UST-10LN Specification Date: 2016.3.24 Scanning Laser Range Finder Smart-URG mini UST-10LN Specification Symbol Amended Reason Pages Date Corrector Amendment No Approved by Checked by Drawn by Designed by UST-10LN Specification

More information

TECHNICAL MANUAL EDITION 1.0 VANDAL RESISTANT AUDIO AND VIDEO DOOR ENTRY SYSTEMS

TECHNICAL MANUAL EDITION 1.0 VANDAL RESISTANT AUDIO AND VIDEO DOOR ENTRY SYSTEMS TECHNICAL MANUAL EDITION 1.0 VANDAL RESISTANT AUDIO AND VIDEO DOOR ENTRY SYSTEMS PAGE 2 of 24 AUDIO/VIDEO VANDAL RESISTANT TECHNICAL MANUAL VER1.0 CONTENTS PAGE Manual introduction 4 System introduction

More information

INSTRUCTIONS FOR THE 8500 SERIES MICROPROCESSOR BASED TEMPERATURE CONTROL

INSTRUCTIONS FOR THE 8500 SERIES MICROPROCESSOR BASED TEMPERATURE CONTROL INSTRUCTIONS FOR THE 8500 SERIES MICROPROCESSOR BASED TEMPERATURE CONTROL December, 1998 Page 1 949-1275-1 TABLE OF CONTENTS MODEL IDENTIFICATION... 4 INSTALLATION... 4 WIRING... 5 FRONT PANEL KEY FUNCTIONS...

More information

BA374C Intrinsically safe field mounting indicating temperature transmitter

BA374C Intrinsically safe field mounting indicating temperature transmitter BA374C Intrinsically safe field mounting indicating temperature transmitter Issue: 5 3rd December 2003 CONTENTS 1. Description 2. Operation 2.1 Controls 3. Intrinsic Safety Certification 3.1 ATEX certificate

More information

SHIMADEN DIGITAL INDICATORS

SHIMADEN DIGITAL INDICATORS Shimaden, Temperature and Humidity Control Specialists C %RH MICROPROCESSOR-BASED SHIMADEN DIGITAL INDICATORS & NRTL /C approved BASIC FEATURES DIN Size 48 x 96 mm ±.25% High Accuracy Indication User-Selectable

More information

AH3000 SERIES 180MM CHART PEN TYPE HYBRID RECORDER

AH3000 SERIES 180MM CHART PEN TYPE HYBRID RECORDER AH3000 SERIES 180MM CHART PEN TYPE HYBRID RECORDER MODEL AH3 7 P - - A AH3000 series conforming to CE, UL and CSA are 180mm pen type hybrid recorders with a simultaneous display of multi-channel data,

More information

MICROJET RECORDER (180mm)

MICROJET RECORDER (180mm) MICROJET RECORDER (180mm) DATA SHEET This recorder can record a maximum of 12 channels of DC voltage, ma, thermocouples and resistance bulbs. The adoption of an ink jet system makes it possible to record

More information

TAIE. Features. FY900 (96mm X 96mm) Application:Control temperature,humidity, FY Series Digital PID Controller

TAIE. Features. FY900 (96mm X 96mm) Application:Control temperature,humidity, FY Series Digital PID Controller TAIE FY Series Digital PID Controller FY900 (96mm X 96mm) Application:Control temperature,humidity, FY series controllers are microprocessor based controllers. Which have been Designed with high accuracy

More information

SPA 2 IS. IECEx. Programmable Limit Alarm Trips with Intrinsically-Safe Field Connections

SPA 2 IS. IECEx. Programmable Limit Alarm Trips with Intrinsically-Safe Field Connections April 2016 Description The universal SPA 2 IS Programmable Limit Alarm Trips provide on/off control, warn of unwanted process conditions, alarm on rate-of-change and provide emergency shutdown. Very versatile,

More information

ET10 Series Stand-alone LCD Fan Coil Thermostat

ET10 Series Stand-alone LCD Fan Coil Thermostat ET10 Series Stand-alone LCD Fan Coil Thermostat Features Modern Appearance Stylish Rotary dial and buttons Large LCD with backlight Separate power supply unit with high performance relay outputs Retention

More information

Carbon Monoxide Transmitter

Carbon Monoxide Transmitter Introduction The CO Transmitter uses an electrochemical sensor to monitor the carbon monoxide level and outputs a field-selectable 4-20 ma or voltage signal. The voltage signal may also be set to 0-5 or

More information

MODEL: 47LT. Digital Panel Meters 47 Series. [3] DISPLAY COLOR R: Red YR: Orange G: Green BG: Bluegreen B: Blue W: White. [4] POWER INPUT AC Power

MODEL: 47LT. Digital Panel Meters 47 Series. [3] DISPLAY COLOR R: Red YR: Orange G: Green BG: Bluegreen B: Blue W: White. [4] POWER INPUT AC Power Digital Panel Meters 47 Series THERMOCOUPLE INPUT DIGITAL PANEL METER (4-digit, LED display type) Functions & Features 4-digit thermocouple input digital panel meter 1/8 DIN size Moving average function

More information

21-light Remote Annunciator. Owner s Manual

21-light Remote Annunciator. Owner s Manual 21-light Remote Annunciator Owner s Manual Annunciator Description... Inside Font Cover Detailed Specifications... 1 Environmental Specifications... 1 Power Supply Requirements... 1 Communication With

More information