and Product Data VTP Selection Guide

Size: px
Start display at page:

Download "and Product Data VTP Selection Guide"

Transcription

1 Selection Guide and Product Data This section has two parts: A Selection Guide that walks you through the process of selecting the correct VTP device for a circuit. Product Data that outlines electrical characteristics, physical characteristics, agency recognition, environmental specifications, and ordering information for VTP devices. VTP Selection Guide Follow these seven steps to select a PolySwitch VTP device for a circuit: 1. Define the operating parameters for the circuit. These include: Maximum internal battery pack operating temperature during normal charge/discharge Maximum battery pack charge/discharge current during normal operation Maximum operating voltage Maximum interrupt current 2. Select the VTP device that accommodates the circuit s maximum ambient operating temperature and normal operating current. 3. Compare the VTP device s maximum operating voltage and maximum interrupt current with the circuit s to be sure the circuit does not exceed the device ratings.. Check the VTP device s time-to-trip to be sure it will protect the circuit. 5. Verify that the circuit s ambient operating temperatures are within the VTP device s operating temperature range. 6. Verify that the VTP device s dimensions fit the application s space considerations. 7. Independently evaluate and test the suitability and performance of the VTP device in the application. Raychem Circuit Protection Devices VTP Devices 265

2 1. Define the circuit s operating parameters. Fill in the following information about the circuit: Maximum internal battery pack operating temperature Normal charge/discharge current Maximum operating voltage Maximum interrupt current 2. Select the PolySwitch VTP device that will accommodate the circuit s maximum internal battery pack operating temperature and normal operating current. Look across the top of the table on the next page to find the temperature that most closely matches the maximum internal battery pack operating temperature experienced during normal charge/discharge. Look down column one to find the value equal to or greater than the maximum battery pack charge/discharge current during normal operation. At the intersection of the current and the temperature you will find the VTP device that will provide the fastest trip time for a given fault condition. If a longer reaction time or a lower resistance is desired, select a device with a higher hold current. If the operating current or temperature falls between the values shown on the table, choose the next highest value for operating current or temperature. Prismatic packs VTP210 devices feature a low-profile form factor for use with prismatic packs. These devices are also available in a slitted lead version. These designs have a slit in one of the leads to facilitate welding of the device to the positive terminal and are identified by the S designation (such as VTP210S). AAA Cell packs VTP170 devices feature a unique small axial strap form factor for use with AAA cell packs. 266 VTP Devices Raychem Circuit Protection Devices

3 I Hold vs. temperature VTP Current * Maximum internal battery pack operating temperature ( C) (amps) VTP170 VTP170 VTP170 VTP170 VTP170 VTP170 VTP VTP170 VTP170 VTP170 VTP170 VTP170 VTP170 VTP210(S) 0.8 VTP170 VTP170 VTP170 VTP170 VTP170 VTP210(S) ** 0.9 VTP170 VTP170 VTP170 VTP170 VTP210(S) ** ** 1.0 VTP170 VTP170 VTP170 VTP170 VTP210(S) ** ** 1.1 VTP170 VTP170 VTP170 VTP210(S) ** ** ** 1.2 VTP170 VTP170 VTP210(S) VTP210(S) ** ** ** 1.3 VTP170 VTP210(S) VTP210(S) ** ** ** ** 1. VTP210(S) VTP210(S) ** ** ** ** ** 1.5 VTP210(S) VTP210(S) ** ** ** ** ** 1.6 VTP210(S) ** ** ** ** ** ** 1.7 ** ** ** ** ** ** ** * Maximum normal charge/discharge current. **Application may be possible by using two devices in parallel. Hold current for two devices in parallel will be less than two times the hold current of one device. In order to minimize interactions, thermally separate the parts as much as possible. Part Maximum ambient operating temperature number VTP VTP210G VTP210S VTP210L Thermal derating curve 200 Percent of rated hold current (at 25 C) Device ambient temperature ( C) Raychem Circuit Protection Devices VTP Devices 267

4 3. Compare maximum operating voltages and maximum interrupt currents. Look down the first column of the table below to find the part number you selected in Step 2. Look to the right in that row to find the device s maximum operating voltage (V max.) and maximum interrupt current (I max.). Compare both ratings with the circuit s to be sure the circuit s rating does not exceed that of the VTP device. Maximum device voltages and currents Part V max. I max. number (Vdc) (amps) VTP VTP210G VTP210S VTP210L VTP Devices Raychem Circuit Protection Devices

5 . Determine time-to-trip. Time-to-trip is the amount of time it takes for a device to switch to a highresistance state once a fault current has been applied through the device. Identifying the VTP device s time-to-trip is important in order to provide the desired protection capabilities. If the device you choose trips too fast, undesired or nuisance tripping will occur. If the device trips too slowly, the components being protected may be damaged before the device switches to a high-resistance state. The chart below shows the typical time-to-trip at 25 C for each PolySwitch VTP device. For example, the chart indicates that the typical time-to-trip for VTP210 at 10 A is 1.7 seconds. Typical time-to-trip curve (25 C) A = VTP210 B = VTP Time-to-trip (s) B A Fault current (A) 100 Raychem Circuit Protection Devices VTP Devices 269

6 5. Verify ambient operating conditions. Ensure that your application s minimum and maximum ambient temperatures are within the operating temperature range of -0 C to 85 C. The maximum surface temperature of the device in the tripped state is 110 C. 6. Verify the VTP device s dimensions Using dimensions from the table below, compare the dimensions of the VTP device you selected with the application s space considerations. Product dimensions (millimeters/inches) Part A B C D F number Fig. min. max. min. max. min. max. min. max. min. max. VTP (0.60) 17.5(0.69) 7.0 (0.27) 7.(0.29) 0.5 (0.02) 0.8 (0.03).0 (0.16) 6.2(0.2).0 (0.16)** VTP210G (0.82) 23.1(0.91).9 (0.19) 5.3(0.21) 0.6 (0.02) 0.8 (0.03).1 (0.16) 5.8(0.23) 3.9 (0.15).1(0.16) VTP210S (0.82) 23.1(0.91).9 (0.19) 5.3(0.21) 0.6 (0.02) 0.8 (0.03).1 (0.16) 5.8(0.23) 3.9 (0.15).1(0.16) VTP210L (0.9) 26.0(1.02).9 (0.19) 5.3(0.21) 0.6 (0.02) 0.8 (0.03) 5.0 (0.20) 7.1(0.28) 3.9 (0.15).1(0.16) *Dimensions in inches are approximate. **Typical dimension. D A D C D A D C F B F Slit: 0.5mm x.0 mm nom. (0.02 in x 0.16 in) 7. Verify the performance of the VTP device Actual installation conditions may affect the performance of the device. Test the recommended device inside the battery pack to verify performance. 270 VTP Devices Raychem Circuit Protection Devices

7 Product Data VTP Now that you have selected your VTP device, please review the device s characteristics in this section to verify that the device will perform as required. Electrical characteristics (25 C) Initial Post-trip Maximum resistance resistance Part IH IT time-to-trip P d max. R min. R max. R 1 max number (A) (A) A) (W) (Ω) (Ω) (Ω) VTP VTP210G VTP210S VTP210L I H = Hold current maximum current at which the device will not trip at 25 C still air. I T = Trip current minimum current at which the device will always trip at 25 C still air. Time-to-trip = Time needed, from onset of fault condition, to trip a PolySwitch device. P d = Maximum power dissipated from device when in the tripped state in 25 C still air. R min./r max. = Device resistance at 25 C prior to tripping. R 1 = Resistance one hour after device is tripped at 25 C. Physical characteristics Lead material Insulating material 0.13-mm nominal thickness, quarter-hard nickel Polyester tape Agency recognition UL File # E7889 Environmental characteristics Resistance Test Conditions change Passive aging -0 C, 1000 hours ±5% 60 C, 1000 hours ±10% Humidity aging 60/95% RH, 1000 hours ±10% Thermal shock 85 C, -0 C (10 times) ±5% Vibration MIL-STD-883D, Method 2026 No change Ordering information VTP devices are bulk packaged. The table below shows the quantities for each. Part number Parts per bag Standard package VTP170 1,000 10,000 VTP210G 1,000 10,000 VTP210S 1,000 10,000 VTP210L 1,000 10,000 Note: For other packaging options, please contact your local Raychem representative. Raychem Circuit Protection Devices VTP Devices 271

8 Part numbering system VTP S G = Global design (standard product) S = Slit lead L = Long lead Hold current rating Part marking system Example V - V V V V V Part identification Raychem symbol Lot identification Part description VTP170 VTP210G VTP210S VTP210L Part identification V17 V21 V21 V21 WARNING: Operation beyond maximum ratings or improper use may result in device damage and possible electrical arcing and flame. These devices are intended for protection against occasional overcurrent or overtemperature fault conditions, and should not be used when repeated fault conditions are anticipated. 272 VTP Devices Raychem Circuit Protection Devices

RUE Selection Guide and Product Data. RUE Selection Guide

RUE Selection Guide and Product Data. RUE Selection Guide Selection Guide and Product Data This section has two parts: A Selection Guide that walks you through the process of selecting the correct RUE device for a circuit. Product Data that outlines electrical

More information

PolySwitch TS600 Overcurrent Protection Devices

PolySwitch TS600 Overcurrent Protection Devices R PolySwitch TS600 Overcurrent Protection Devices New surface-mount products for overcurrent protection Raychem introduces the PolySwitch TS600 series to protect sensitive telecommunications equipment

More information

DATASHEET PolySwitch RKEF Devices

DATASHEET PolySwitch RKEF Devices DTSHEET PolySwitch Devices For use in a wide variety of general electronic products, ranging from industrial controls to battery packs, PolySwitch devices are functionally equivalent to the PolySwitch

More information

PolySwitch Surface-mount Resettable Devices

PolySwitch Surface-mount Resettable Devices PolySwitch Surface-mount Resettable evices Surface-mount More than ten years ago, Raychem ircuit Protection introduced the SM product family, and polymeric PT devices quickly became the computer industry

More information

SiBar Thyristor Surge Protectors. TVBxxxNSA-L Series. Benefits: Features: Applications:

SiBar Thyristor Surge Protectors. TVBxxxNSA-L Series. Benefits: Features: Applications: Raychem Circuit Protection's SiBar thyristor surge protection devices are designed to help protect sensitive telecommunication equipment from the hazards caused by lightning, power contact, and power induction.

More information

SiBar Thyristor Surge Protectors. TVBxxxRSC-L Series. Benefits: Features: Applications:

SiBar Thyristor Surge Protectors. TVBxxxRSC-L Series. Benefits: Features: Applications: Circuit Protection's SiBar thyristor surge protection devices are designed to help protect sensitive telecommunication equipment from the hazards caused by lightning, power contact, and power induction.

More information

SiBar Thyristor Surge Protectors. TVBxxxSA-L Series. Benefits: Features: Applications:

SiBar Thyristor Surge Protectors. TVBxxxSA-L Series. Benefits: Features: Applications: Raychem Circuit Protection's SiBar thyristor surge protection devices are designed to help protect sensitive telecommunication equipment from the hazards caused by lightning, power contact, and power induction.

More information

Telecom Fuses. Benefits. Features. Applications

Telecom Fuses. Benefits. Features. Applications Telecom Fuses The FT600 fuse series is designed to assist telecommunications equipment manufacturers in complying with North American overcurrent protection requirements, including Telcordia GR- 1089,

More information

SEALED ENCLOSURE COOLING

SEALED ENCLOSURE COOLING ADVANCED COOLING TECHNOLOGIES The Thermal Management Experts www.1-act.com SEALED ENCLOSURE COOLING ABOVE-AMBIENT AND SUB-AMBIENT COOLING PRODUCTS TABLE OF CONTENTS HEAT SINK COOLER (ACT-HSC) HEAT EXCHANGER

More information

Table of Contents. Protective Relays

Table of Contents. Protective Relays Table of Contents KILOVAC WD Series, DIN Rail or Screw Mounted Introduction..........................................................11-2 KILOVAC WD25 Paralleling Relays........................................11-3

More information

Specification Status: Released

Specification Status: Released PAGE NO.: 1 OF 5 GENERAL DESCRIPTION BENEFITS Specification Status: Released Helps provide overvoltage fault protection against high energy surges Suitable for sensitive equipment due to excellent impulse

More information

Technical Paper. PPTC Circuit Protection for Power Management in Portable Communications/PDA Equipment

Technical Paper. PPTC Circuit Protection for Power Management in Portable Communications/PDA Equipment Technical Paper PPTC Circuit for Power Management in Portable Communications/PDA Equipment PPTC Circuit for Power Management in Portable Communications/PDA Equipment Frank Owen - Marketing Director Raychem

More information

KILOVAC K1K High-Voltage Contactor

KILOVAC K1K High-Voltage Contactor KILOVAC K1K High-Voltage Contactor High Performance in a Compact, Lightweight, Hermetically Sealed Contactor Designed for up to 1000 V/1000 A in Harsh Environments KILOVAC K1K High-Voltage Contactor Compact,

More information

PolySwitch Telecommunications and Networking Resettable Devices

PolySwitch Telecommunications and Networking Resettable Devices Telecommunications and Networking PolySwitch Telecommunications and Networking Resettable Devices PolySwitch devices for telecommunication and networking applications were initially designed over ten years

More information

XL-Trace System Application and Design Guide

XL-Trace System Application and Design Guide R XL-Trace System Application and Design Guide Pipe Freeze Protection and Flow Maintenance for Commercial Construction Applications Pipe Freeze Protection and Flow Maintenance 1. Pipe Freeze Protection

More information

STANDARDS UPDATE NOTICE (SUN) ISSUED: August 23, 2017

STANDARDS UPDATE NOTICE (SUN) ISSUED: August 23, 2017 STANDARDS UPDATE NOTICE (SUN) ISSUED: August 23, 2017 STANDARD INFORMATION Standard Number: UL 412 Standard Name: Refrigeration Unit Coolers Standard Edition and Issue Date: 5 th Edition Dated August 22,

More information

DGC-500 DIGITAL GENSET CONTROLLER

DGC-500 DIGITAL GENSET CONTROLLER DGC-500 DIGITAL GENSET CONTROLLER Basler Electric s Digital Genset Controller (DGC-500) offers a low cost microprocessor based integrated alternative for the control and monitoring of small to medium sized

More information

AD0412HB-C71GP (P) P.S. REV. DC FAN (RoHS)

AD0412HB-C71GP (P) P.S. REV. DC FAN (RoHS) AD0412HB-C71GP DC FAN (RoHS) P.S. REV. (P) A Y D A T A - S H E E T Engineering Printed On: 11/07/18 BRUSHLESS AXIAL COOLING FANS Customer Ref: (RoHS) Adda Model No AD0412HB-C71GP P.S: (P) Samples attached

More information

DGC-1000 DIGITAL GENSET CONTROLLER

DGC-1000 DIGITAL GENSET CONTROLLER DGC-1000 DIGITAL GENSET CONTROLLER Basler Electric s Digital Genset Controller (DGC-1000) offers a low cost microprocessor based integrated alternative for small to medium sized genset control and monitoring.

More information

HHS-WWH HOPPER HEATING SYSTEM WRAP-WOUND HEATER INSTALLATION INSTRUCTIONS DESCRIPTION. HHS-WWH PRODUCT SPECIfICATIONS

HHS-WWH HOPPER HEATING SYSTEM WRAP-WOUND HEATER INSTALLATION INSTRUCTIONS DESCRIPTION. HHS-WWH PRODUCT SPECIfICATIONS HHS-WWH HOPPER HEATING SYSTEM WRAP-WOUND HEATER INSTALLATION INSTRUCTIONS HHS-WWH PRODUCT SPECIfICATIONS Power density Standard wattages up to 4650 W/m² (3.0 W/in²) Voltage range (nominal) 120 to 600 VAC

More information

BE1-50/51B with S1 Case or FT-11 sized Case and Cover For non-retrofit applications, see Product Bulletin UHD.

BE1-50/51B with S1 Case or FT-11 sized Case and Cover For non-retrofit applications, see Product Bulletin UHD. BE1-50/51B SELF POWERED TIME OVERCURRENT RELAY RETROFIT KITS BE1-50/51B with S1 Case or FT-11 sized Case and Cover For non-retrofit applications, see Product Bulletin UHD. BE1-50/51B, CO Retrofits BE1-50/51B,

More information

Revision: None DCN No. First Issue Date: November 30, 1998 Product: Standard DCT, 120-volts

Revision: None DCN No. First Issue Date: November 30, 1998 Product: Standard DCT, 120-volts Figure 1Document: SPEC-112 Revision: None DCN No. First Issue Date: November 30, 1998 Product: Standard DCT, 120-volts construction requirements of UL approved Class H (180 C) insulation system. Transformers

More information

Products :: Circuit Protection :: Thermal Circuit Breakers

Products :: Circuit Protection :: Thermal Circuit Breakers Products :: Circuit Protection :: Thermal Circuit Breakers Thermal Circuit Breaker CTB-Series CTB-Series PDF elibrary The CTB-Series is a compact, single pole, rocker actuated family of thermal circuit

More information

DET-TRONICS SPECIFICATION DATA. Eagle Quantum EQ2200UVHT For Use With C7050B Continuous Duty High Temperature UV Flame Detector DESCRIPTION

DET-TRONICS SPECIFICATION DATA. Eagle Quantum EQ2200UVHT For Use With C7050B Continuous Duty High Temperature UV Flame Detector DESCRIPTION DET-TRONICS SPECIFICATION DATA Eagle Quantum EQ2200UVHT For Use With C7050B Continuous Duty High Temperature UV Flame Detector DESCRIPTION The EQ2200UVHT UV Flame Detector is used with the Eagle Quantum

More information

Specification Status: Released

Specification Status: Released PAGE NO.: 1 OF 6 GENERAL DESCRIPTION BENEFITS Specification Status: Released Helps provide overvoltage fault protection against high energy surges Suitable for sensitive equipment due to excellent impulse

More information

Distributed by: www.jameco.com 1-800-831-4242 The content and copyrights of the attached material are the property of its owner. GENERAL DESCRIPTION The ROV14-XXX (Radial-leaded Metal Oxide Varistor) products

More information

HOT WATER TEMPERATURE MAINTENANCE HWAT SYSTEM

HOT WATER TEMPERATURE MAINTENANCE HWAT SYSTEM HOT WATER TEMPERATURE MAINTENANCE HWAT SYSTEM This step-by-step design guide provides the tools necessary to design a Raychem HWAT Hot Water Temperature Maintenance System. For additional information,

More information

SPECIFICATIONS FOR REFOND SURFACE MOUNT LED

SPECIFICATIONS FOR REFOND SURFACE MOUNT LED SPECIFICATIONS FOR REFOND SURFACE MOUNT LED Model: RF-WNB190DS-DC Company Name: Confirmed By Customer: DATE: Feature Viewing angle:140 deg The materials of the chip is InGaN 1.60mm 0.80mm 0.70mm SMT-LED

More information

SERVICE MANUAL FOR 6636A & 6636B SERIES TWO TON HIGH EFFICIENCY PACKAGED AIR CONDITIONERS

SERVICE MANUAL FOR 6636A & 6636B SERIES TWO TON HIGH EFFICIENCY PACKAGED AIR CONDITIONERS SERVICE MANUAL FOR 6636A & 6636B SERIES TWO TON HIGH EFFICIENCY PACKAGED AIR CONDITIONERS TABLE OF CONTENTS 1. Warnings & Component Match-Up............................................ 2 2. Unit Specifications..........................................................

More information

Austin Series Non-Isolated SMT DC - DC Power Modules: 3.3 Vdc and 5.0 Vdc Input, 1.5 Vdc Vdc Output, 6A

Austin Series Non-Isolated SMT DC - DC Power Modules: 3.3 Vdc and 5.0 Vdc Input, 1.5 Vdc Vdc Output, 6A Data Sheet Document No: DS04-004 ver. 1.1 PDF Name: austin.pdf Titania Power Modules Austin Series Non-Isolated SMT DC - DC Power Modules: Features The Austin Power Module Series provides precise voltage

More information

Pipe Freeze Protection. Flow Maintenance. Introduction. XL-Trace System

Pipe Freeze Protection. Flow Maintenance. Introduction. XL-Trace System Pipe Freeze Protection and Flow Maintenance 1. Pipe Freeze Protection and Flow Maintenance Introduction XL-Trace System This step-by-step design guide provides the tools necessary to design a Raychem XL-Trace

More information

研發處 研發處 研發處 研發處 簡文榮 林茂盛 AD0612LB-A73GL P.S. REV. DC FAN (RoHS) 研發處

研發處 研發處 研發處 研發處 簡文榮 林茂盛 AD0612LB-A73GL P.S. REV. DC FAN (RoHS) 研發處 簡文榮 林茂盛 甘順騫 黃淑慧 AD0612LB-A73GL DC FAN (RoHS) P.S. REV. A Y D A T A - S H E E T Engineering BRUSHLESS AXIAL COOLING FANS Customer Adda Model No AD0612LB-A73GL Samples attached Piece(s), Safety Approval

More information

30.45 Electric Release PDRP-2001

30.45 Electric Release PDRP-2001 The PDRP-2001 Fire Alarm Control Panel (FACP) is a six-zone control panel for single and dual hazard deluge and preaction applications. The FACP is compatible with conventional input devices (2-wire or

More information

(P) AD0612VB-A7BGP P.S. REV. DC FAN (RoHS)

(P) AD0612VB-A7BGP P.S. REV. DC FAN (RoHS) AD0612VB-A7BGP DC FAN (RoHS) P.S. REV. (P) C Y D A T A - S H E E T Engineering BRUSHLESS AXIAL COOLING FANS Customer Adda Model No AD0612VB-A7BGP P.S: (P) Samples attached Piece(s), Safety Approval UL,CUL,TUV,CE

More information

JBS-100-ECP-A COMBINATION POWER CONNECTION BOX AND DIGITAL ELECTRONIC CONTROLLER INSTALLATION INSTRUCTIONS

JBS-100-ECP-A COMBINATION POWER CONNECTION BOX AND DIGITAL ELECTRONIC CONTROLLER INSTALLATION INSTRUCTIONS JBS-100-ECP-A COMBINATION POWER CONNECTION BOX AND DIGITAL ELECTRONIC CONTROLLER INSTALLATION INSTRUCTIONS JBS-100-ECP-A with Pyrotenax MI heating cable using required MI cable grounding kit JBS-100-ECP-A

More information

Installation Instructions CS3 Three Phase Solid State Relay

Installation Instructions CS3 Three Phase Solid State Relay Installation Instructions CS3 Three Phase Solid State elay 1 PK522-3 0037-75550 March 2018 Important Safeguards HIGH VOLTAGE is used in the operation of this equipment; DEATH ON CONTACT may result if personnel

More information

32 Tips to Consider Before Purchasing an Electrical Enclosure Air Conditioner TABLE OF CONTENTS INTRODUCTION... 3 TECHNICAL FEATURES 4

32 Tips to Consider Before Purchasing an Electrical Enclosure Air Conditioner TABLE OF CONTENTS INTRODUCTION... 3 TECHNICAL FEATURES 4 TABLE OF CONTENTS INTRODUCTION... 3 TECHNICAL FEATURES 4 ENVIRONMENTAL ASPECTS.. 6 SPECIAL REQUIREMENTS.. 8 MANUFACTURER CONSIDERATIONS.. 8 SELECTING AN ENCLOSURE AIR CONDITIONER.... 9 2 Although the selection

More information

Be sure DC power is applied safely to terminals 3-4. Use caution during testing.

Be sure DC power is applied safely to terminals 3-4. Use caution during testing. BE1-46N SCOPE This test procedure covers the testing of the Basler BE1-46N negative sequence current relay. Refer to IM 9170000990 Rev. L (12/12) for testing support information and component level identification.

More information

Linear Current Sensors

Linear Current Sensors Solid State Sensors Linear Current Sensors CS Series FEATURES Linear output AC or DC current sensing Through-hole design Fast response time Output voltage isolation from input Minimum energy dissipation

More information

SMPG3 SNOW MELTING AND DE-ICING POWER DISTRIBUTION AND CONTROL PANEL. For three-phase heating cables PRODUCT OVERVIEW

SMPG3 SNOW MELTING AND DE-ICING POWER DISTRIBUTION AND CONTROL PANEL. For three-phase heating cables PRODUCT OVERVIEW SNOW MELTING AND DE-ICING POWER DISTRIBUTION AND CONTROL PANEL For three-phase heating cables Mounting brackets Nameplate HTC energized light Power on light Heater cycle timed control Heater (3R only)

More information

Design Guide Design Notes Design Examples Technical Data Sheets Expanded Capabilities Specifications Warranty

Design Guide Design Notes Design Examples Technical Data Sheets Expanded Capabilities Specifications Warranty Introduction HWAT Design Guide This step-by-step design guide provides the tools necessary to design a Raychem HWAT Hot Water Temperature Maintenance System. For additional information, contact your Pentair

More information

Multi-Output Access Control Power Supply Charger VDC or 24VDC VDC or 3 24VDC.

Multi-Output Access Control Power Supply Charger VDC or 24VDC VDC or 3 24VDC. M Series Multi-Output Access Control Power Supply Charger Installation Guide Models Include: AL300ULM AL400ULM - 2.5 amp @ 12VDC or 24VDC. - 4 amp @ 12VDC or 3 amp @ 24VDC. AL600ULM AL1012ULM - 6 amp @

More information

Freezer Frost Heave Prevention

Freezer Frost Heave Prevention Freezer Frost Heave Prevention 1. Pipe Freeze Protection and Flow Maintenance RaySol System Mineral Insulated Heating Cable System This step-by-step design guide provides the tools necessary to design

More information

DP 300 mobile dew point instrument

DP 300 mobile dew point instrument Instruction manual DP 300 mobile dew point instrument For measuring pressure, dew point and atmospheric dew point in different applications: Compressed air plants (refrigeration/ adsorption dryer) Granulate

More information

PS1240x Series Dual Voltage Access Control Power Supply Systems Operating and Installation Instructions Rev D.01

PS1240x Series Dual Voltage Access Control Power Supply Systems Operating and Installation Instructions Rev D.01 PS1240x Series Dual Voltage Access Control Power Supply Systems Operating and Installation Instructions Warnings and Notices WARNING - To reduce the risk of fire or electric shock, do not expose this product

More information

GROUND FAULT PROTECTION PANELs. the power to protect GPD/GPFJ TYPES GPD, GPFJ, GPAD AND GPAFJ

GROUND FAULT PROTECTION PANELs. the power to protect GPD/GPFJ TYPES GPD, GPFJ, GPAD AND GPAFJ GPD/GPFJ GROUND FAULT PROTECTION PANELs the power to protect TYPES GPD, GPFJ, GPAD AND GPAFJ Instruction Manual C-231EM Revision February 2009 ground fault protection panels The I-GARD Ground Fault Protection

More information

FreezGard. Self-regulating crankcase heater. Product Overview

FreezGard. Self-regulating crankcase heater. Product Overview Self-regulating crankcase heater Product Overview When compressors operate in cold areas, refrigerant can migrate into the crankcase oil whenever the compressor is not running. On start-up, this can cause

More information

PolySwitch Telecommunications and Networking Resettable Devices

PolySwitch Telecommunications and Networking Resettable Devices Telecommunications and Networking PolySwitch Telecommunications and Networking Resettable evices PolySwitch devices for telecommunication and networking applications were initially designed over ten years

More information

PS6 SERIES. Installation PS6 SERIES. Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option

PS6 SERIES. Installation PS6 SERIES. Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option Installation PS6 SERIES Power Supplies PS6 SERIES Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option Installation and Specifications Manual ISDPS6_SERIES 08121590 PCN15016 R05/15GR

More information

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual MANUAL Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual Model FPT 130 Single Point Freeze Protection Heat Trace Control Table of Contents SCFP-CO-F130 Overview... 3 Installation...

More information

Motogard. Over Temperature Protection System. Installation Instructions

Motogard. Over Temperature Protection System. Installation Instructions Motogard Over Temperature Protection System Installation Instructions Motogard General Information Motogard Over-Temperature Protection Systems provide immediate overheating protection for: motors, equipment

More information

Duct and Rough Service Carbon Monoxide Sensor

Duct and Rough Service Carbon Monoxide Sensor Product Identification and Overview Duct and Rough Service Carbon Monoxide Sensor BAPI s Carbon Monoxide Sensor offers enhanced electrochemical sensing with outstanding accuracy at low concentrations.

More information

ECW-GF, ECW-GF-DP DIGITAL ELECTRONIC CONTROLLERS AND REMOTE DISPLAY PANEL PRODUCT OVERVIEW

ECW-GF, ECW-GF-DP DIGITAL ELECTRONIC CONTROLLERS AND REMOTE DISPLAY PANEL PRODUCT OVERVIEW DIGITAL ELECTRONIC CONTROLLERS AND REMOTE DISPLAY PANEL ECW-GF with FTC-PSK pipe stand and power connection kit ECW-GF using RayClic power connection kit ECW-GF-DP remote display panel available only with

More information

Used as indicators of indicating the Degree, Functions, Positions etc, in electronic instruments

Used as indicators of indicating the Degree, Functions, Positions etc, in electronic instruments Features Low power consumption High efficiency and low cost Good control and free combinations on the colors of LED lamps Good lock and easy to assembly. Stackable and easy to assembly Stackable vertically

More information

180 Degree Ceiling Mounted Occupancy Sensors

180 Degree Ceiling Mounted Occupancy Sensors Instruction Bulletin 63249-420-386A 2/202 80 Degree Ceiling Mounted Occupancy Sensors PS-CDS800 and PS-CUS800 INTRODUCTION The 80 Degree Ceiling Mount Occupancy Sensors are ideal for use in business and

More information

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL TRACON MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL TABLE OF CONTENTS FPT 130 Overview... 2 Installation... 3 Power Source and Load Connections... 4 Temperature Sensor... 5 External

More information

Heat Tracing Sales Mt. Airy, Maryland Heating Cable. Cut to Length in Field. Description

Heat Tracing Sales Mt. Airy, Maryland Heating Cable. Cut to Length in Field. Description Self-Regulating Protection D E C B A Self-Regulating, Energy Efficient Designed for Protection Max. Exposure Temp. 185 F (Power Off) Cost Effective for Commercial Construction Protection Applications Protection

More information

TM-3100 Series Room Temperature Sensor

TM-3100 Series Room Temperature Sensor PB_TM-3100_12 2009 TM-3100 Series Room Temperature Sensor The Johnson Controls TM-3100 Series Room Temperature Sensor provide passive sensing of temperature in HVAC application. The TM-3100 is equipped

More information

A214B/SUG/S400-X6 LAMP. Features. Description. Applications. Revision 1. Expired Period: Forever. LifecyclePhase: Low power consumption

A214B/SUG/S400-X6 LAMP. Features. Description. Applications. Revision 1. Expired Period: Forever. LifecyclePhase: Low power consumption Features Low power consumption High efficiency and low cost Good control and free combinations on the colors of LED lamps Good lock and easy to assembly. Stackable and easy to assembly Stackable vertically

More information

Multi-Output Access Control Power Supply Chargers VDC or 24VDC VDC or 4 24VDC.

Multi-Output Access Control Power Supply Chargers VDC or 24VDC VDC or 4 24VDC. M Series Multi-Output Access Control Power Supply Chargers Installation Guide Models Include: AL300ULM AL400ULM - 2.5 amp @ 12VDC or 24VDC. - 3 amp @ 12VDC or 4 amp @ 24VDC. AL600ULM AL1012ULM - 6 amp

More information

Integrated Process Solutions. Series 48 Heaters. heater jackets sizes 1 1/2'' to 4'' (nw 40 to nw 100)

Integrated Process Solutions. Series 48 Heaters. heater jackets sizes 1 1/2'' to 4'' (nw 40 to nw 100) Integrated Process Solutions w w w. m k s i n s t. c o m Series 48 s heater jackets sizes 1 1/2'' to 4'' (nw 40 to nw 100) Series 48 heaters have been designed for safety, flexibility, power conservation,

More information

AF/GF dual-purpose receptacles

AF/GF dual-purpose receptacles Eaton Wiring Devices OBC AF/GF dual-purpose receptacles AF/GF dual-purpose receptacles Arc fault and ground fault protection in one device In Stock July 2016! Eaton Wiring Devices OBC AF/GF dual-purpose

More information

PolySwitch Surface-Mount Resettable Fuses

PolySwitch Surface-Mount Resettable Fuses PolySwitch Surface-Mount Resettable Fuses New surface-mount products reduce the footprint and extend the operating range of the broadest product line of surface-mount resettable fuses Raychem, inventor

More information

Raychem Overvoltage Devices. ROV14, ROV14H, ROV14E 14mm Series Metal Oxide Varistors

Raychem Overvoltage Devices. ROV14, ROV14H, ROV14E 14mm Series Metal Oxide Varistors GENERAL DESCRIPTION The ROV14-XXX (Radial-leaded Metal Oxide Varistor) products are 14mm radial leaded varistor devices suitable for protection of overvoltage transients. ROV devices can provide protection

More information

Afci TR Duplex 20A 125V La. Features amperage rating 20. Dimensions and Weight Width 3.3. Long Description

Afci TR Duplex 20A 125V La. Features amperage rating 20. Dimensions and Weight Width 3.3. Long Description 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 TRAFCI20LA Afci TR Duplex 20A 125V La Eaton Wiring Devices Catalog Number Manufacturer Weight per unit Product Category

More information

Test Methods for Consideration Into Radio Standard

Test Methods for Consideration Into Radio Standard Test Methods for Consideration Into Radio Standard Jason Allen March 20,2013 Test Methods for Consideration Into Radio Standard Reviewed many current NFPA standards including: NFPA 1971- Structural and

More information

SPECIFICATION FOR APPROVAL. Customer Description Part No.. Model No. JDD VBBA51(0A24) Sample Issue No. Sample Issue Date

SPECIFICATION FOR APPROVAL. Customer Description Part No.. Model No. JDD VBBA51(0A24) Sample Issue No. Sample Issue Date JARO THERMAL SPECIFICATION FOR APPROVAL Customer Description Part No.. Model No. JDD0402812VBBA51(0A24) Sample Issue No. Sample Issue Date REV.0 V Preliminary Specification Formal Specification PREPARED

More information

NON-CYCLING REFRIGERATED AIR/GAS DRYERS QPNC 75 to QPNC 250 OPERATOR S MANUAL

NON-CYCLING REFRIGERATED AIR/GAS DRYERS QPNC 75 to QPNC 250 OPERATOR S MANUAL NON-CYCLING REFRIGERATED AIR/GAS DRYERS QPNC 75 to QPNC 250 OPERATOR S MANUAL DATE OF PURCHASE: MODEL: SERIAL NO.: Record above information from nameplate. Retain this information for future reference.

More information

an ISO9001 company APPLICATION NOTES FOR TGS2611 Application Notes for Methane Gas Detectors using TGS2611

an ISO9001 company APPLICATION NOTES FOR TGS2611 Application Notes for Methane Gas Detectors using TGS2611 Application Notes for Methane Gas Detectors using TGS2611 an ISO9001 company The TGS2611 methane gas sensor has been presorted into groupings which will allow users to simplify the manufacturing process

More information

5800-OD Wireless Outdoor Motion Sensor Installation Instructions

5800-OD Wireless Outdoor Motion Sensor Installation Instructions GENERAL INFORMATION The Honeywell 5800-OD Wireless Outdoor Motion Sensor (referred to as the 5800-OD) combines the convenience of wireless technology with a full featured outdoor PIR motion sensor. The

More information

FIRE SPRINKLER SYSTEM FREEZE PROTECTION XL-TRACE SYSTEM

FIRE SPRINKLER SYSTEM FREEZE PROTECTION XL-TRACE SYSTEM FIRE SPRINKLER SYSTEM FREEZE PROTECTION XL-TRACE SYSTEM This step-by-step design guide provides the tools necessary to design a Raychem XL-Trace fire sprinkler freeze protection system. For other applications

More information

ICS Regent. Fire Detector Input Modules PD-6032 (T3419)

ICS Regent. Fire Detector Input Modules PD-6032 (T3419) ICS Regent Fire Detector Input Modules (T3419) Issue 1, March, 06 Fire detector input modules provide interfaces for 16 fire detector inputs such as smoke detectors, flame detectors, temperature detectors,

More information

SAFETY MANUAL. FL4000H and FL4000 Multi-Spectral Infrared Flame Detectors

SAFETY MANUAL. FL4000H and FL4000 Multi-Spectral Infrared Flame Detectors SAFETY MANUAL FL4000H and FL4000 Multi-Spectral Infrared Flame Detectors The information and technical data disclosed in this document may be used and disseminated only for the purposes and to the extent

More information

SMPG1 SNOW MELTING AND DE-ICING POWER DISTRIBUTION AND CONTROL PANEL FOR SINGLE-PHASE HEATING CABLES PRODUCT OVERVIEW

SMPG1 SNOW MELTING AND DE-ICING POWER DISTRIBUTION AND CONTROL PANEL FOR SINGLE-PHASE HEATING CABLES PRODUCT OVERVIEW SMPG1 SNOW MELTING AND DE-ICING POWER DISTRIBUTION AND CONTROL PANEL FOR SINGLE-PHASE HEATING CABLES Mounting brackets Heater thermostat (3R only) Power on light HTC energized light Heater (3R only) Snow/Ice

More information

7800 SERIES EC7823/RM7823 Relay Module

7800 SERIES EC7823/RM7823 Relay Module 7800 SERIES EC7823/RM7823 Relay Module FEATURES SPECIFICATION DATA APPLICATION The Honeywell EC7823/RM7823 is a microprocessor based Flame Detector Relay that can be fitted with any 7800 SERIES amplifier

More information

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 350 SERIES CIRCULATION HEATERS

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 350 SERIES CIRCULATION HEATERS INDEECO Circulation Heaters are designed to provide years of trouble free operation if properly installed and maintained. Please read and follow these instructions for installing and maintaining the heater.

More information

TrueAlarm Smoke Detectors

TrueAlarm Smoke Detectors UL, ULC Approved* TrueAlarm Smoke Detectors TrueAlarm Photoelectric Smoke Detector with TrueSense Smoke/Heat Detection Features detection. If any of these alarm conditions are experienced, an alarm is

More information

"ESDDR" Series Electric Humidifier

ESDDR Series Electric Humidifier ESDDR-1 Deionized, Demineralized, or Reverse Osmosis Water "ESDDR" Series Electric Humidifier The Electric Humidifier from PURE Humidifier Co. is loaded with features and options. All you need is deionized,

More information

SPECIFICATION SUBMITTAL

SPECIFICATION SUBMITTAL SPECIFICATION SUBMITTAL The dimmer with remote control One tap on to selected light level/off; two taps full bright;press & hold for 10-second fade-tooff Press rocker to adjust light level Front accessible

More information

Basic Vehicle Fire Protection Manual

Basic Vehicle Fire Protection Manual Basic Vehicle Fire Protection Manual Basic Vehicle Fire Protection Manual TABLE OF CONTENTS Introduction... 3 System Operation...... 5 Component Overview.... 7 Operator Controls Control Panel.........

More information

Model 60200FR Gas Primary Control Data Sheet

Model 60200FR Gas Primary Control Data Sheet Programmable, Microprocessor Based Gas Burner Primary Controls On-Board LCD Screen Easy to Understand Icons for Inputs and Outputs Displays micro-amp Flame reading Display operational information Fault

More information

Liebert PPC Second Generation Power Distribution Cabinet

Liebert PPC Second Generation Power Distribution Cabinet Liebert PPC Second Generation Power Distribution Cabinet Emerson Network Power Delivers The Packaged Power Solution Creating high quality power is a major step towards protecting the operation of a critical

More information

Electric Coils. Blower Coils. Product Information

Electric Coils. Blower Coils. Product Information Product Information General Information Electric heat coils are an available accessory for use with Price blower coil units. The electric heating coils have been specific ally designed to suit Price blower

More information

SLATE. Burner Control Module INSTALLATION INSTRUCTIONS R8001B2001

SLATE. Burner Control Module INSTALLATION INSTRUCTIONS R8001B2001 SLATE Burner Control Module R8001B2001 INSTALLATION INSTRUCTIONS Scan for more information Application SLATE brings configurable safety and programmable logic together into one single platform. The platform

More information

SECTION POWER SUPPLIES AND DISTRIBUTION

SECTION POWER SUPPLIES AND DISTRIBUTION SECTION 17460 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes requirements for Power Supplies and Power Distribution for Station communications. 1.02 REFERENCE STANDARDS A. American National Standards

More information

Protection Chain IQ-Sensor + Relaiy device T420

Protection Chain IQ-Sensor + Relaiy device T420 APPLICATION NOTES Protection Chain IQ-Sensor + T420 Protection Chain IQ-Sensor + Relaiy device T420 According to IEC 61508 SAFETY Integrity Level 2 I N C H A R G E O F S P E E D 2/7 1 Introduction This

More information

THERMAL MANAGEMENT SOLUTIONS

THERMAL MANAGEMENT SOLUTIONS DIGITAL ELECTRONIC CONTROLLERS AND REMOTE DISPLAY PANEL ECW-GF with FTC-PSK pipe stand and power connection kit ECW-GF using RayClic power connection kit ECW-GF-DP remote display panel available only with

More information

Technical Data Sheet 3mm Phototransistor T-1

Technical Data Sheet 3mm Phototransistor T-1 Technical Data Sheet 3mm Phototransistor T-1 Features Fast response time High photo sensitivity Pb free The product itself will remain within RoHS compliant version. PT24-6C Descriptions PT24-6C is a high

More information

7800 SERIES EC7885A/RM7885A Relay Module

7800 SERIES EC7885A/RM7885A Relay Module 7800 SERIES EC7885A/RM7885A Relay Module SPECIFICATION DATA 1. Torch-ignited main burner using the S445A Start-Stop Station, or any conventional knee or foot operated start-stop station. 2. Torch-ignited

More information

Afci TR Duplex 20A 125V Iv. Features amperage rating. Dimensions and Weight. Descriptions

Afci TR Duplex 20A 125V Iv. Features amperage rating. Dimensions and Weight. Descriptions 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 TRAFCI20V Afci TR Duplex 20A 125V Iv Eaton Wiring Devices Catalog Number Manufacturer Description Weight per unit Product

More information

Revised Record 研發處發行章 Rev. Revision Description Change page Date A00 Preliminary

Revised Record 研發處發行章 Rev. Revision Description Change page Date A00 Preliminary 璟宜 研發處 簡文榮 研發處 朱程宇 研發處 黃高川 研發處 歐陽語彤 AD3512MX-K73(X) MOLEX:2695-3P 300mm SA-0120161219013 A00 研發處 發行章 Revised Record Rev. Revision Description Change page Date A00 Preliminary D A T A - S H E E T Engineering

More information

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual We manage heat MANUAL Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual 1850 N Sheridan Street South Bend, Indiana 46628 (574) 233-1202 or (800) 234-4239

More information

Raychem Overvoltage Devices. ROV05, ROV05H 5mm Series Metal Oxide Varistors

Raychem Overvoltage Devices. ROV05, ROV05H 5mm Series Metal Oxide Varistors Document: SCD Rev. A June 30, 003 GENERAL DESCRIPTION The ROV0-XXX (Radial-leaded Metal Oxide Varistor) products are mm radial leaded varistor devices suitable for protection of overvoltage transients.

More information

GE Industrial Solutions. Residential Electronic Circuit Interrupters

GE Industrial Solutions. Residential Electronic Circuit Interrupters GE Industrial Solutions Residential Electronic Circuit Interrupters Dual Function Circuit Interrupter (DFCI) Provides ground fault and arc fault circuit protection in one unit The 2014 National Electric

More information

GRUNDFOS INSTRUCTIONS LCD 108. Installation and operating instructions

GRUNDFOS INSTRUCTIONS LCD 108. Installation and operating instructions GRUNDFOS INSTRUCTIONS LCD 08 Installation and operating instructions Installation and operating instructions Original installation and operating instructions CONTENTS Page. Symbols used in this document.

More information

Use & Care Manual. Electric Tankless Water Heaters. With Installation Instructions for the Installer AP15447 (10/10)

Use & Care Manual. Electric Tankless Water Heaters. With Installation Instructions for the Installer AP15447 (10/10) Use & Care Manual With Installation Instructions for the Installer Electric Tankless Water Heaters The purpose of this manual is twofold: one, to provide the installer with the basic directions and recommendations

More information

Installation and Operation Instructions ELECTRIC FIREPLACE CAM35WMEF

Installation and Operation Instructions ELECTRIC FIREPLACE CAM35WMEF Installation and Operation Instructions ELECTRIC FIREPLACE CAM35WMEF Important Safety Instructions Listing Approvals Product Dimensions Locating Fireplace Unpacking and Testing Fireplace Grounding Instructions

More information

DIP Switches Series. Performance Characteristics Series. Materials. Technical Documents

DIP Switches Series. Performance Characteristics Series. Materials. Technical Documents lcoswitch DIP switches are available in standard single pole, single throw; side actuated, single pole, single throw and multiple series versions. Contacts are made of high strength copper alloy with.000030

More information

COMMERCIAL & RESIDENTIAL SELF-REGULATING HEATING PRODUCTS APPLICATION AND DESIGN GUIDE EUROPE, MIDDLE EAST, AFRICA

COMMERCIAL & RESIDENTIAL SELF-REGULATING HEATING PRODUCTS APPLICATION AND DESIGN GUIDE   EUROPE, MIDDLE EAST, AFRICA WWW.PENTAIRTHERMAL.COM NORTH AMERICA Tel: +1.800.545.6258 Fax: +1.800.527.5703 Tel: +1.650.216.1526 Fax: +1.650.474.7711 thermal.info@pentair.com ASIA PACIFIC Tel: +86.21.2412.1688 Fax: +86.21.5426.2917

More information

TRUERH Series HE-67xx Humidity Element with Temperature Sensor

TRUERH Series HE-67xx Humidity Element with Temperature Sensor Installation Instructions HE-67xx Issue Date 0501 TRUERH Series HE-67xx Humidity Element with Temperature Sensor Installation IMPORTANT: The HE-67xx Series Humidity Element with Temperature Sensor is designed

More information