Airchime Steam Whistles

Size: px
Start display at page:

Download "Airchime Steam Whistles"

Transcription

1 Airchime Steam Whistles Indoor or Outdoor Use S1 Series > Indoor and outdoor use > Coated steel or bronze finish > 165 to 200 PSIG (11.6 to 14.1 kg/sq cm) > Single tone > Activated by a 120V AC 60Hz solenoid valve (purchased separately - See page 8-15) > Frequency dependent upon whistle size Steam whistles may be used for general signaling applications. The sound is generated by means of a resonant cylinder which resounds when a difference in pressure is caused by air or steam passing by the edge of the open cylinder. These whistles may be used in indoor or outdoor applications. Designed for mounting on air or steam supply piping, supplying between 165 and 200 PSIG (11.6 and 14.1 kg/sq cm). Steam whistles may be installed in mines, refineries, and industrial plants. They can be used to signal shift changes, equipment troubles, or for other general signal applications. A A AIRCHIME is a registered trademark of Airchime Manufacturing Co. Ltd. dbc* Steam Inlet Consumption Dimension Frequency at 100 ft NPT lbs/sec (kg/sec) A (in) Material S1-1x /4" (6mm) 0.08 (.04) 2" (51mm) Coated Steel S1-2x /2" (13mm) 0.10 (.05) 4" (102mm) Coated Steel S1-4x " (25mm) 0.93 (.42) 8" (203mm) Bronze S1-6x /2" (38mm) 1.58 (.72) 12" (305mm) Bronze *When operated at 165 to 200 PSIG 8-14

2 Airchime Steam Whistle Valves Normally closed, 120 volt solenoid valve used to activate Edwards Airchime Steam Whistles. Designed for mounting on air or steam supply piping, supplying between 165 and 200 PSIG (11.6 to 14.1 kg/sq cm). Steam whistle valves are designed for use with Edwards Airchime Steam Whistles. Steam whistles may be installed in mines, refineries, and industrial plants. They can be used to signal shift changes, equipment troubles, or for other general signal applications. > Bronze body with stainless steel insert > NPT inlets > 165 to 200 psig (11.6 to 14.1 kg/sq cm) Inlet Voltage NPT N5 120VAC 60Hz 1/4" (6mm) N5 120VAC 60Hz 1/2" (13mm) N5 120VAC 60Hz 1" (25mm) N5 120VAC 60Hz 1 1/2" (38mm) AIRCHIME is a registered trademark of Airchime Manufacturing Co. Ltd. 8-15

3 HORNS & SIRENS Klaxon Manual Horn Unique "Klaxon" Sound > Completely assembled > Projector type > Complete with mounting bracket > No electricity required > 95dB at 10 ft (3.05m) > Frequency Hz ES Series Manually operated horn that sounds the familiar and unique Klaxon sound. The horn is easily operated by either hand or foot. The ES is designed for bracket mounting using the housing bracket. It may also be used as a portable unit. The ES is ideal for construction sites and other areas where a portable audible signal is required or where no electrical power is available. 6 25/32" (172) 2 15/16" (75) 5" (127) 4 Fixing Holes 3/16" (5) 1" (25) 4 7/8" Dia. (124) 5/8" (16) ES Finish Gray KLAXON is a registered trademark of Klaxon Signals Ltd. 6-32

4 Airchime Steam Whistle Valves Normally closed, 120 volt solenoid valve used to activate Edwards Airchime Steam Whistles. Designed for mounting on air or steam supply piping, supplying between 165 and 200 PSIG (11.6 to 14.1 kg/sq cm). Steam whistle valves are designed for use with Edwards Airchime Steam Whistles. Steam whistles may be installed in mines, refineries, and industrial plants. They can be used to signal shift changes, equipment troubles, or for other general signal applications. > Bronze body with stainless steel insert > NPT inlets > 165 to 200 psig (11.6 to 14.1 kg/sq cm) Inlet Voltage NPT N5 120VAC 60Hz 1/4" (6mm) N5 120VAC 60Hz 1/2" (13mm) N5 120VAC 60Hz 1" (25mm) N5 120VAC 60Hz 1 1/2" (38mm) AIRCHIME is a registered trademark of Airchime Manufacturing Co. Ltd. 8-15

5 Airchime Air Horns Portable CO2-5, CO2-10 & PF-1625 CO2-5 CO2-5 & CO2-10 For use with any Model "C" horn. Five pound (CO2-5) or ten pound (CO2-10) CO 2 bottle comes complete with mounting bracket for direct mounting of the selected horn to the bottle. Bottle is rechargeable at any fire extinguisher service shop. PF-1625 CO2-10 PF-1625 A small, compact hand-held signal for general signaling use. May be used for indoor or outdoor general signaling services. The PF generates sound by means of a vibrating diaphragm that modulates the flow of compressed gas into a resonating projector. The horn shape is mathematically calculated to amplify sound while closely retaining its fundamental frequency and natural harmonics. These signals are ideal for use in job areas that require a portable signal. Easy to move from location to location. Excellent for emergency signaling applications such as in mines, quarries, refineries, construction and industrial sites. CO2-5 & CO2-10 > Flange for direct mounting of horn to bottle > Effective range - 1/4 mile (.4 km)* PF-1625 > Replaceable cartridge > Push to operate > Non ozone depleting > Effective range - 1/4 mile (.4 km)* * Subject to environmental and geographical conditions, these models have a typical effective range of 1/4 mile (.4 km) assuming an ambient background level of 60dB, a line pressure of 100 psi (7.03 kg/sq cm) and temperature of 60 F (15.6 C). Derated per FEMA 10 db per distance doubled. AIRCHIME is a registered trademark of Airchime Manufacturing Co. Ltd. CO2-5 > When fully charged, good for 600 to 700 short blasts > Activated by squeezing the handle CO2-10 > When fully charged, good for 1000 to 1500 short blasts 8-17

6 Airchime Air Horn Control Valves Solenoid Valves > Local or remote operation > Hazardous location approved Combination Valves > Manual and solenoid control Solenoid, combination, and manual control valves are designed for use with Edwards Airchime Air Horns. Air horns may be used for emergency signaling applications in mines, refineries and industrial facilities. Ideal for individual equipment and plant warnings. > Hazardous location approved > Provides for operation in event of power failure Manual Valves > Lanyard or whistle pull AGENCY APPROVALS > UL Approved for Closure Type 3, 4, 7, and 9 valves > UL Listed for Class I, Division 1, Groups C and D and Class II, Division 1, Groups E, F, and G Valve Type Pipe Thread Volts Solenoid 3/8" (10mm) NPT * Solenoid 1/2" (13mm) NPT * Solenoid 3/4" (19mm) NPT * Solenoid 1 1/4" (32mm) NPT * Solenoid/Manual 3/8" (10mm) NPT * Solenoid/Manual 1/2" (13mm) NPT * Solenoid/Manual 3/4" (19mm) NPT * Solenoid/Manual 1 1/4" (32mm) NPT * Manual 3/8" (10mm) NPT Manual 1/2" (13mm) NPT Manual 3/4" (19mm) NPT Manual 1 1/4" (32mm) NPT *Specify voltage: N5-120V AC, G5-24V AC, G1-24V DC AIRCHIME is a registered trademark of Airchime Manufacturing Co. Ltd. 8-22

7 Omni-Directional Edwards Warning Siren 107 db, Skirted Horn Design > ft. (30.5 m) > Omni-directional > Continuous duty motor > Skirted horn design > Powder coated exterior > Three phase motor: - 5 HP 208/230/460 V 60 Hz. - Starting amps: 66 - Running amps: 12 > Single phase motor: - 5 HP 230 V 60 Hz. - Starting amps: Running amps: 23 > Port tone frequency: 460 cps > Weight: 250 lbs. (113.4 kg) > Max. diameter: 34" (86.4 cm) > Max. height: 34" (86.4 kg) > Max. mounting base: 19" (48.3 cm) sq. > Estimated sound circle: 3200 ft. (975.4 m) continuous EWS-V1 Series Lots of power in a small package. Great versatility - whether you are supplying a large industry, small community, or filling dead spots, the 107 db rated omni-directional EWS-V1 Series is the answer. The non-corrosive, cast aluminum fan is powered by a 5 Hp motor in your choice of single or three phase power, and produces a port tone frequency of 460 cycles per second. All exposed siren components are made of zinc plated, steel construction, which are powder coated for the most durable finish available. The fan and housing are both made of non-corrosive cast aluminum. Maximum diameter of the EWS-V1 Series is 34" (86.4 cm), maximum height is 34" (86.4 cm), and the maximum dimensions of mounting base are 19" (48.3 cm) square. Shipping weight of the siren alone is 250 lbs (113.4 kg). ORDERING INFORMATION & ACCESSORIES Description EWS-V1-3 Outdoor warning siren - three phase motor EWS-V1 Outdoor warning siren - single phase motor EWS-MS-V1-3 Remote magnetic motor starter - 3 phase EWS-MS-V1-3-W Remote magnetic motor starter - 3 phase, weatherproof EWS-MS-V1 Remote magnetic motor starter - 1 phase EWS-MS-V1-W Remote magnetic motor starter - 1 phase, weatherproof EWS-CDP-3 Three Function Siren control center EWS-CDP-1 Two Function Siren control center EWS-T-1 Single Function Siren control center ENC-H Radio control - hand held ENC-D Radio control - desk mount EWS-PMB Utility pole mounting bracket - powder coat finish EWS-PMB-SS Utility pole mounting bracket - stainless steel finish See page 8-13 for additional accessory information. 8-4

8 Omni-Directional Edwards Warning Siren 109 db, 8 Horn, Equal Length, Single Row EWS-V2 Series Edwards EWS-V2 Series combine large siren functions with cost effectiveness making it ideal for small towns or volunteer fire departments. Utilizing the same effective design and construction as the EWS-V1, the EWS-V2 Series uses projectors to distribute and organize sound. Rated at 109 db, the EWS-V2 is an omni-directional siren that produces continuous 360 coverage. The EWS-V2 Series is available in either single or three phase power. It is a single tone siren, producing 460 cycles per second. All exposed siren components are of zinc plated steel construction, which are powder coated for the most durable finish available. The fan and housing are made of non-corrosive cast aluminum. Maximum diameter of the Model EWS-V1 Series is 34" (86.4 cm), maximum height is 34" (86.4 cm), and the maximum dimensions of mounting base are 19" (48.3 cm) square. Shipping weight of the siren alone is 250 lbs (113.4 kg). ORDERING INFORMATION & ACCESSORIES Description EWS-V2-3 Outdoor warning siren - three phase motor EWS-V2 Outdoor warning siren - single phase motor EWS-MS-V1-3 Remote magnetic motor starter - 3 phase EWS-MS-V1-3-W Remote magnetic motor starter - 3 phase, weatherproof EWS-MS-V1 Remote magnetic motor starter - 1 phase EWS-MS-V1-W Remote magnetic motor starter - 1 phase, weatherproof EWS-CDP-3 Three Function Siren control center EWS-CDP-1 Two Function Siren control center EWS-T-1 One Function Siren control center ENC-H Radio control - hand held ENC-D Radio control - desk mount EWS-PMB Utility pole mounting bracket - powder coat finish EWS-PMB-SS Utility pole mounting bracket - stainless steel finish See page 8-13 for additional accessory information. > ft. (30.5 m) > Omni-directional > Continuous duty motor > 8 horn, equal length, single row > Powder coated exterior > Three phase motor: - 5 HP 208/230/460 V 60 Hz. - Starting amps: 66 - Running amps: 12 > Single phase motor: - 5 HP 230 V 60 Hz. - Starting amps: Running amps: 23 > Port tone frequency: 460 cps > Weight: 250 lbs. (113.4 kg) > Max. diameter: 34" (86.4 cm) > Max. height: 34" (86.4 cm) > Max. mounting base: 19" (48.3 cm) sq. > Estimated sound circle: 4,000 ft. (1,219.2 m) continuous 8-5

9 8-6 > AC model ft. (30.5m) DC model ft. (30.5m) > Continuous duty motor > 8 horn, equal length, single row > Powder coated exterior > Three phase motor (EWS-V3): HP 208/230/460 V 60 Hz. - Starting amps: Running amps: 19 > Single phase motor (EWS-V3): HP 230 V 60 Hz. - Starting amps: Running amps: 37 > Port tone frequency: 460 cps > Weight: 350 lbs. (158.8 kg) > Max. diameter: 56" (142.2 cm) > Max. height: 41" (104.1 cm) > Max. mounting base: 19" (48.3 cm) sq. > Estimated sound circle: 5,000 ft. (1524 m) continuous (AC Model) > Estimated sound circle: 7,000 ft. ( m) continuous (DC Model) Omni-Directional Edwards Warning Siren 112 & 118 db, 8 Horn, Equal Length, Single Row EWS-V3 & EWS-V10 Series Employing carefully designed horns to project sound over long distances, the EWS-V3 Series is Edwards newest model. The EWS-V3 is rated at 112 db and like most of Edwards outdoor warning sirens, is Omni-Directional. The EWS-V10 is a battery powered version of the EWS-V3. The EWS-V10 includes a motor starter, charging system and battery box. The EWS-V3 is available in single phase or three phase and is a single tone siren, producing 460 cycles per second, for optimal sound penetration. All exposed siren components are of metal construction, which are powder coated for the most durable finish available. The fan and housing are made of non-corrosive cast aluminum. Maximum diameter of the EWS-V3 and EWS-V10 is 56" (142.2 cm), maximum height is 41" (104.1 cm), and the maximum mounting base dimension is 19" (48.3 cm) square. Shipping weight of the siren is 350 lbs (158.8 kg). ORDERING INFORMATION & ACCESSORIES Description EWS-V3-3 Outdoor warning siren - three phase motor EWS-V3 Outdoor warning siren - single phase motor EWS-V10 Outdoor warning siren - Battery Powered EWS-MS-V3-3 Remote magnetic motor starter - 3 phase EWS-MS-V3-3-W Remote magnetic motor starter - 3 phase, weatherproof EWS-MS-V3 Remote magnetic motor starter - 1 phase EWS-MS-V3-W Remote magnetic motor starter - 1 phase, weatherproof EWS-CDP-3 Three Function Siren control center EWS-CDP-1 Two Function Siren control center EWS-T-1 One Function Siren control center ENC-H Radio control - hand held ENC-D Radio control - desk mount EWS-PMB Utility pole mounting bracket - powder coat finish EWS-PMB-SS Utility pole mounting bracket - stainless steel finish See page 8-13 for additional accessory information.

10 Omni-Directional Edwards Warning Siren 115 db, 8 Horn, Staggered Length, Single Row EWS-V4 Series Edwards most popular mid-sized siren is a proven performer. Staged horn projectors help organize sound for even distribution over a large radius. Rated at 115 db, the EWS-V4 Series is an omni-directional siren which produces continuous 360 coverage, making it a superior alternative to a directional beam siren. The perfect siren for small communities, the EWS-V4 is available in either single or three phase power and is a single tone siren, producing 460 cycles per second. All exposed siren components are of metal construction, which are powder coated for the most durable finish available. The fan and housing are made of non-corrosive cast aluminum. Maximum diameter is 78" (198.1 cm), maximum height is 56" (142.2 cm), and the maximum mounting base dimension is 19" (48.3 cm) square. Shipping weight of the siren alone is 325 lbs (147.4 kg). ORDERING INFORMATION & ACCESSORIES Description EWS-V4-3 Outdoor warning siren - three phase motor EWS-V4 Outdoor warning siren - single phase motor EWS-MS-V4-3 Remote magnetic motor starter - 3 phase EWS-MS-V4-3-W Remote magnetic motor starter - 3 phase, weatherproof EWS-MS-V4 Remote magnetic motor starter - 1 phase EWS-MS-V4-W Remote magnetic motor starter - 1 phase, weatherproof EWS-CDP-3 Three Function Siren control center EWS-CDP-1 Two Function Siren control center EWS-T-1 One Function Siren control center ENC-H Radio control - hand held ENC-D Radio control - desk mount EWS-PMB Utility pole mounting bracket - powder coat finish EWS-PMB-SS Utility pole mounting bracket - stainless steel finish See page 8-13 for additional accessory information. > ft. (30.5 m) > Omni-Directional > Continuous duty motor > 8 horn, staggered length, single row > Powder coated exterior > Three phase motor: - 10 HP 208/230/460 V 60 Hz. - Starting amps: Running amps: 24 > Single phase motor: - 10 HP 230 V 60 Hz. - Starting amps: Running amps: 47 > Port tone frequency: 460 cps > Weight: 325 lbs (147.4 kg). > Max. diameter: 78" (198.1 cm) > Max. height: 56" (142.2 cm) > Max. mounting base: 19" (48.3 cm) sq. > Estimated sound circle: 6,000 ft. ( m) continuous 8-7

11 8-8 > ft. (30.5 m) > Omni-Directional > Continuous duty motor > 8 horn, staggered length, dual row > Powder coated exterior > Three phase motor: - 10 HP 208/230/460 V 60 Hz. - Starting amps: Running amps: 24 > Single phase motor: - (2) 7.5 HP 230 V 60 Hz. motors - Starting amps: Running amps: 74 * NOTE: Uses two starters > Port tone freq.: 460 & 920 cps > Weight: 600 lbs. (272.2 kg) > Max. diameter: 78" (198.1 cm) > Max. height: 66" (167.6 cm) > Max. mounting base: 19" (48.3 cm) sq. > Estimated sound circle: 8,000 ft. ( m) continuous Omni-Directional Edwards Warning Siren 120 db, 8 Horn, Staggered Length, Dual Row EWS-V5 Series Our most affordable dual tone siren, the EWS-V5 Series is designed to excel in almost any application. Its staged horn projectors provide a large, even coverage area. Rated at 122 db, the Model EWS-V5 is an omni-directional siren which produces continuous 360 coverage, a clear advantage over rotating sirens. The EWS-V5 is available in either single or three phase power. It is a dual tone siren, employing two rotors with different numbers of ports to produce a greater range of frequency. One rotor produces 460 cycles per second, and the other produces 920. All exposed siren components are of zinc plated, steel construction, which are powder coated for the most durable finish available. The fan and housing are made of non-corrosive cast aluminum. Maximum diameter of the siren is 78" (198.1 cm), maximum height is 65" (165.1 cm), and the maximum mounting base is 19" (48.3 cm) square. Shipping weight of the siren alone is 600 lbs (272.2 kg). ORDERING INFORMATION & ACCESSORIES Description EWS-V5-3 Outdoor warning siren - three phase motor EWS-V5 Outdoor warning siren - single phase motor EWS-MS-V4-3 Remote magnetic motor starter - 3 phase EWS-MS-V4-3-W Remote magnetic motor starter - 3 phase, weatherproof EWS-MS-V4 Remote magnetic motor starter - 1 phase EWS-MS-V4-W Remote magnetic motor starter - 1 phase, weatherproof EWS-CDP-3 Three Function Siren control center EWS-CDP-1 Two Function Siren control center EWS-T-1 One Function Siren control center ENC-H Radio control - hand held ENC-D Radio control - desk mount EWS-PMB Utility pole mounting bracket - powder coat finish EWS-PMB-SS Utility pole mounting bracket - stainless steel finish See page 8-13 for additional accessory information.

12 Omni-Directional Edwards Warning Siren 122 & 125 db, 8 Horn, Equal Length, Dual Row EWS-V6 & EWS-V9 Series Designed for medium or small, growing communities this siren is a true workhorse. It is also our most popular dual tone siren. Rated at 122 db, the EWS-V6 is an omni-directional siren which produces continuous 360 coverage, making it a superior alternative to a rotating siren. The EWS-V9 is a battery powered version of the EWS-V6. The EWS-V9 includes a motor starter, charging system and battery box. The EWS-V6 is available in either single or three phase power. Both the EWS-V6 and EWS-V9 are dual tone sirens, employing two rotors with different numbers of ports to produce a greater range of frequency. One rotor produces 460 cycles per second, and the other produces 920 cycles per second. All exposed siren components are of metal construction, which are powder coated for the most durable finish available. The fan and housing are made of non-corrosive cast aluminum. ORDERING INFORMATION & ACCESSORIES Description EWS-V6-3 Outdoor warning siren - three phase motor EWS-V6 Outdoor warning siren - single phase motor EWS-V9 Outdoor warning siren - DC motor EWS-MS-V6-3 Remote magnetic motor starter - 3 phase EWS-MS-V6-3-W Remote magnetic motor starter - 3 phase, weatherproof EWS-MS-V6 Remote magnetic motor starter - 1 phase EWS-MS-V6-W Remote magnetic motor starter - 1 phase, weatherproof EWS-CDP-3 Three Function Siren control center EWS-CDP-1 Two Function Siren control center EWS-T-1 One Function Siren control center ENC-H Radio control - hand held ENC-D Radio control - desk mount EWS-PMB Utility pole mounting bracket - powder coat finish EWS-PMB-SS Utility pole mounting bracket - stainless steel finish See page 8-13 for additional accessory information. > AC model ft. (30.5 m) DC model ft. (30.5 m) > Omni-Directional > Continuous duty motor > 8 horn, equal length, dual row > Three phase motor: - 15 HP 208/230/460 V 60 Hz. - Starting amps: Running amps: 36 > Single phase motor: - (2) 7.5 HP 230V 60 Hz. motors - Starting amps: Running amps: 72 * NOTE: Uses two starters > Port tone frequency: 460 cps > Weight: 750 lbs. > Max. diameter: 78" (198.1 cm) > Max. height: 65" (165.1 cm) > Max. mounting base: 19" (48.3 cm) sq. > Estimated sound circle: 9,400 ft. ( m) continuous (AC model) 11,000 ft. continuous ( m) (DC model) 8-9

13 8-10 > ft.m (30.5 m) > Omni-Directional > Continuous duty motor > 8 horn, staggered length, dual row > Powder coated exterior > Three phase motor: - 20 HP 208/230/460 V 60 Hz. - Starting amps: Running amps: 47 > Single phase motor: - (2) 10 HP 230 V 60 Hz. motors - Starting amps: Running amps: 94 * NOTE: Uses two starters > Port tone freq.: 460 & 920 cps > Weight: 750 lbs. (340.2 kg) > Max. diameter: 78" (198.1 cm) > Max. height: 56" (142.2 cm) > Max. mounting base: 19" (48.3 cm) sq. > Estimated sound circle: 10,500 ft. ( m) continuous Omni-Directional Edwards Warning Siren 124 db, 8 Horn, Staggered Length, Dual Row EWS-V7 Series The Edwards EWS-V7 Series is large enough to tackle almost any application. Taking advantage of a continuous duty industrial motor and rated at 124 db, the EWS-V7 is an omni-directional siren which produces continuous 360 coverage, making it a superior alternative to a directional beam type siren. The EWS-V7 is available in either single or three phase power, and is a dual tone siren, employing two rotors with different numbers of ports to produce a greater range of frequency. One rotor produces 460 cycles per second, and the other produces 920 cycles per second. All exposed siren components are of metal construction, which are powder coated for the most durable finish available. The fan and housing are made of non-corrosive cast aluminum. Maximum diameter is 78" (198.1 cm), maximum height is 56" (142.2 cm), and the maximum mounting base dimension is 19" (48.3 cm) square. Shipping weight of the siren alone is 750 lbs (340.2 kg). ORDERING INFORMATION & ACCESSORIES Description EWS-V7-3 Outdoor warning siren - three phase motor EWS-V7 Outdoor warning siren - single phase motor EWS-MS-V7-3 Remote magnetic motor starter - 3 phase EWS-MS-V7-3-W Remote magnetic motor starter - 3 phase, weatherproof EWS-MS-V7 Remote magnetic motor starter - 1 phase EWS-MS-V7-W Remote magnetic motor starter - 1 phase, weatherproof EWS-CDP-3 Three Function Siren control center EWS-CDP-1 Two Function Siren control center EWS-T-1 One Function Siren control center ENC-H Radio control - hand held ENC-D Radio control - desk mount EWS-PMB Utility pole mounting bracket - powder coat finish EWS-PMB-SS Utility pole mounting bracket - stainless steel finish See page 8-13 for additional accessory information.

14 Omni-Directional Edwards Warning Siren 127 db, 5 Horn, Equal Length, Dual Row EWS-V8-3 The largest omni-directional siren in existence. Taking advantage of a continuous duty, industrial motor and rated at 127 db, the EWS- V8-3 produces continuous 360 coverage, making it a superior alternative to directional beam type siren. The EWS-V8-3 is available in three phase power only, and is a dual tone siren, employing two rotors with different numbers of ports to produce a greater range of frequency. One rotor produces 600 cycles per second, and the other produces 850 cycles per second. All exposed siren components are of galvanized steel construction, which are powder coated for the most durable finish available. The fan and housing are made of non-corrosive cast aluminum. Maximum diameter of the siren is 78" (198.1 cm), maximum height is 67" (170.2 cm), and the maximum mounting base size is 24" (61 cm) square. Shipping weight of the siren is 1,200 lbs. (544.3 kg). ORDERING INFORMATION & ACCESSORIES Description EWS-V8-3 Outdoor warning siren - three phase motor EEWS-MS-V8-3-W Remote magnetic motor starter - 3 phase, weatherproof EWS-CDP-3 Three Function Siren control center EWS-CDP-1 Two Function Siren control center EWS-T-1 One Function Siren control center ENC-H Radio control - hand held ENC-D Radio control - desk mount EWS-PMB Utility pole mounting bracket - powder coat finish EWS-PMB-SS Utility pole mounting bracket - stainless steel finish See page 8-13 for additional accessory information. > ft. (30.5 m) > Omni-directional > Continuous duty motor > 5 horn, equal length, dual row > Powder coated exterior > Three phase motor: - 40 HP 208/230/460 V 60 Hz. - Starting amps: Running amps: 96 (using 230V power) > Port tone freq.: 600 & 850 cps > Weight: 1,200 lbs. (544.3 kg) > Max. diameter: 78" (198.1 cm) > Max. height: 67" (170.2 cm) > Max. mounting base: 24" (61 cm) sq. > Estimated sound circle: 12,800 ft. ( m) continuous 8-11

15 Rotating Edwards Warning Siren 127 db > ft. (30.5 m) > Maintenance free siren & rotating mechanism > Self-contained electrical connections (battery not included) > Powder coated exterior > 8 HP motor > Port tone freq.: 460 & 920 cps > Weight: 385 lbs. (174.6 kg) > Recommended batteries: - Group 27 sealed lead acid maintenance free (minimum) - GelCel or AGM Optima Blue Top Deep Cycle Marine EWS-11 Series Featuring the industry s largest drive motor, this 8 HP, battery powered rotating siren delivers all the features one expects from a premium warning device. Utilizing a 460 Hz tone, the EWS-11's low pitch is designed to penetrate structures and obstacles, making the warning area more complete. The EWS-11 features the same bullet-proof design and construction as other Edwards sirens. The EWS-11 uses top of the line, maintenance free rotating mechanisims and hand rolled, custom formed projectors. All exposed siren components are of heavy gauge aluminum alloy and electro-plated, galvanized steel construction, which are "powder coated" for the most durable finish available. The entire mass of the siren is centered over the pole so no stabilizing wires are required. Total shipping weight of the EWS-11 is 385 lbs. (174.6 kg). ORDERING INFORMATION & ACCESSORIES Description EWS-11 Outdoor warning siren EWS-H-1 Siren heater w/ thermostat EWS-CDP-3 Three function siren control center EWS-CDP-1 Two function siren control center EWS-T-1 One function siren control center ENC-H Radio control - hand held ENC-D Radio control - desk mount EWS-PMB Utility pole mounting bracket - powder coat finish EWS-PMB-SS Utility pole mounting bracket - stainless steel finish See page 8-13 for additional accessory information. 8-12

16 Airchime Air Horn Industrial Timer Edwards Airchime Industrial Timers are designed for use with Edwards Airchime Air Horns. They are often used with K (pg. 8-6) and KM (pg. 8-8) series units. Air horns may be used for emergency signaling applications in mines, refineries and industrial facilities. Ideal for individual equipment and plant warnings. > Field programmable > 7 day, 24 hour programmable time indication (minimum time interval - 10 minutes) > Fire indication (1/2 second on - 1/2 second off, repeated for 5 minutes) > Emergency alert (1 second on - 3 seconds off, repeated for 5 minutes) > Manual operation - remains on for as long as push button is held > 120V AC 60 Hz AIRCHIME is a registered trademark of Airchime Manufacturing Co. Ltd. 8-23

17 Airchime Air Horns Marine Rated KMJ Series Self-contained air horns are used for applications where an air supply is not available or desired. These units are available in 2 model variations featuring our KMJ-4 or KMJ-5 air horn and consist of a motor directly connected to a rotary compressor. Like a junior model of the famous Airchime KM Series it is designed featuring a horizontal bell with horizontal diaphragm head so that water will drain away from the diaphragm seal. Because the horns are cast in light weight aluminum, they feature excellent corrosion resistance that will give years of trouble free service. All fasteners are corrosion proof stainless steel. No adjustment to diaphragm are necessary. Compliant with collision regulation standards for sound signal appliances at sea (72 COLREGS). A certificate of compliance is issued with each unit at time of purchase. These quality KMJ-SC models meet or exceed the current IMO / Coast Guard collision regulations for Class IV; vessel length less than 20m; and Class III vessel length 20m to 75m. > Cast in light weight aluminum > Corrosion resistant > Ideal horns for vessels under 75 meters in length > Effective range - 1/4 mile (.4km)* > 1/2" (12mm) NPT Inlet > Single tone frequency > Operating range - 15 to 120 PSIG Air Consumption Freq. db(c) db(c) Cu. Ft. /Sec. Net (Hz) at 10 ft. at 100 ft. (Liters/Sec.) Length Weight KMJ-4SC75120VAC /4" 55 lb (1.9) (810mm) (25 kg) KMJ-4SC7524VDC " 55 lb (1.9) (736.6mm) (25 kg) KMJ-5SC120VAC /4" 55 lb (1.8) (666.7mm) (25 kg) KMJ-5SC24VDC /4" 75 lb (1.8) (666.7mm) (34 kg) * Subject to environmental and geographical conditions, these models have a typical effective range of 1/4 mile (.4 km) assuming an ambient background level of 60dB, a line pressure of 60 psi (7.03 kg/sq cm) and temperature of 60 F (15.6 C). Derated per FEMA 10 db per distance doubled. AIRCHIME is a registered trademark of Airchime Manufacturing Co. Ltd. 8-21

18 Airchime Air Horns Marine Rated KM Series > Cast marine aluminum horns - primed and painted > Solid bronze diaphragm head > Patented three piece hermetically sealed diaphragm > Effect. range - 1 1/4 mile (2 km)* > 3/4" (19mm) NPT inlet > Single tone frequency > Operating range - 50 to 150 PSIG (3.5 to 10.5 kg/sq cm) The KM Series horns are the finest and most reliable air horns on the market for very large area coverage. They were developed and proven to meet the most exacting demands of the industrial and commercial trades. The horns generate sound by means of a vibrating diaphragm that modulates the flow of compressed air into a resonating projector. All horn shapes are mathematically calculated to amplify sound while closely retaining its fundamental frequency and natural harmonics. The signal is designed so that moisture naturally drains away from the diaphragm seat. Designed for mounting on air supply piping, supplying between 50 and 150 PSIG (3.5 and 10.5 kg/sq cm). Excellent for pole or roof top installation. Particularly useful for commanding attention to emergency situations in very large areas. Air Consumption Freq. db(c) db(c) Cu. Ft. /Sec. Net (Hz) at 10 ft. at 100 ft. (Liters/Sec.) Length Weight KM /8" 42 lb (67) (1070mm) (19 kg) KM /4" 32 lb (43) (679mm) (14.5 kg) KM /8" 32 lb (38) (543mm) (14.5 kg) * Subject to environmental and geographical conditions, these models have a typical effective range of 1 1/4 mile (2 km) assuming an ambient background level of 60dB, a line pressure of 100 psi (7.03 kg/sq cm) and temperature of 60 F (15.6 C). Derated per FEMA 10 db per distance doubled. AIRCHIME is a registered trademark of Airchime Manufacturing Co. Ltd. 8-20

19 CA Airchime Air Horns C-1E C Series C-12 CA-4 > Corrosion resistant cast bronze body > Stainless steel diaphragm > Machined or spun bell > Effective range - 1/4 mile (.4 km)* > Single or dual tone frequency These air horns are for general signaling services. They generate sound by means of a vibrating diaphragm that modulates the flow of compressed air into a resonating projector. All horn shapes are mathematically calculated to amplify sound while closely retaining its fundamental frequency and natural harmonics. All horn frequencies are designed to give balance to any combination of horn tones. These horns can be used in indoor/outdoor applications, ideal for hazardous location use, individual equipment and plant warnings. Volume is adjustable by regulating air pressure. Designed for mounting on air supply piping, supplying between 50 and 150 PSIG (3.5 and 10.5 kg/sq cm). May be bracket mounted using the AC30106 post bracket. Typical applications include: emergency signaling applications such as mines, refineries and industrial facilities. They can also be used for signaling activities such as shift start/stop, blast warning and equipment stop/starts. Air Consumption Air Pressure Freq. db(c) db(c) Cu. Ft. /Sec. PSI Inlet Net Description (Hz) at 10 ft. at 100 ft. (Liters/Sec.) (Kg/Sq Cm) NPT Length Weight CA Single tone /8" 4 3/4" 3 lb machined bell (7.1) (9.5mm) (120mm) (1.3 kg) CA-4 Omni-directional /2" 11 1/4" 12 lb 4 model CA horns (28.4) (13mm) (286mm) (5.2 kg) CB Single tone /8" 7 3/8" 2 3/4 lb Spun bell (7.1) ( ) (9.5mm) (187mm) (1.2 kg) C-1E Single tone /8" 15 3/4" 3 lb Spun bell (7.1) (9.5mm) (400mm) (1.3kg) C-12 Dual tone 246/ /8" 15 3/4" 8 lb Spun bell (14.2) (9.5mm) (400mm) (3.6 kg) AC30106 Post bracket for Air Horn Cat. No's. CB, C-1E, C-12 and CA * Subject to environmental and geographical conditions, these models have a typical effective range of 1/4 mile (.4 km) assuming an ambient background level of 60dB, a line pressure of 100 psi (7.03 kg/sq cm) and temperature of 60 F (15.6 C). Derated per FEMA 10 db per distance doubled. 8-16

20 K-1 Airchime Air Horns K-12 Single or Dual Tone K-25R25 K Series > Die cast aluminum construction > Adjust volume via air pressure > Hermetically sealed diaphragm > Effect. range - 3/4 mile (1.2 km)* >.5-2 cu ft /sec ( liters/sec) > Operating range - 50 to 150 PSIG (3.5 to 10.5 kg/sq cm) The K series is designed for general signaling services. They generate sound by means of a vibrating diaphragm that modulates the flow of compressed air into a resonating projector. All horn shapes are mathematically calculated to amplify sound while closely retaining its fundamental frequency and natural harmonics. These horns can be used for indoor/outdoor applications and are ideal for hazardous location use. Volume is adjustable by regulating air pressure. Designed for mounting on air supply piping, supplying between 50 and 150 PSIG (3.5 and 10.5 kg/sq cm). Typical applications include emergency signaling applications in mines, refineries and industrial facilities. Ideal for individual equipment and plant warnings. Air Consumption Freq. db(c) db(c) Cu. Ft. /Sec. Inlet Net Weight Description (Hz) at 10 ft. at 100 ft. (Liters/Sec.) NPT Length lbs. (kg) K-1 Single tone, cast base, die cast alu (14) 1/2" (13mm) 16 1/2" (419mm) 7 1/2 (3.4) minum body, 3 piece hermetically sealed stainless steel diaphragm K-2 Same as above (14) 1/2" (13mm) 12 7/8" (327mm) 6 1/2 (2.9) K-3 Same as above (14) 1/2" (13mm) 10 1/4" (260mm) 6 1/4 (2.8) K-5 Same as above (14) 1/2" (13mm) 7 1/2" (191mm) 5 (2.2) K-12 Dual tone incorporating 311/ (28) 1/2" (13mm) 16 1/2" (419mm) 14 1/2 (6.5) K1 & K2 with base K-25 Dual tone incorporating 370/ (28) 1/2" (13mm) 12 7/8" (327mm) 12 (5.4) K2 & K5 with base K-12R12 Dual tone incorporating 311/ (56) 3/4" (19mm) 16 1/2" (419mm) 24 1/2 (11.1) 2 K-12 Air Horns reversed for 180 coverage with base K-25R25 Dual tone incorporating 370/ (56) 3/4" (19mm) 12 7/8" (327mm) 55 (24.9 ) 2 K-25 Air Horns reversed for 180 coverage with base * Subject to environmental and geographical conditions, these models have a typical effective range of 3/4 mile (1.2 km) assuming an ambient background level of 60dB, a line pressure of 100 psi (7.03 kg/sq cm) and temperature of 60 F (15.6 C). Derated per FEMA 10 db per distance doubled. 8-18

21 Airchime Air Horns 360 of Coverage K4 Series The K4 series units are designed for general signaling services and generate sound by means of vibrating diaphragms that modulate the flow of compressed air into resonating projectors. All horn shapes are mathematically calculated to amplify sound while closely retaining its fundamental frequency and natural harmonics. These horns can be used for indoor/outdoor applications and are ideal for hazardous location use. Volume is adjustable by regulating air pressure. Designed for mounting on air supply piping, supplying between 50 and 150 PSIG (3.5 and 10.5 kg/sq cm). Typical applications include emergency signaling applications in mines, refineries and industrial facilities. Ideal for individual equipment and plant warnings. > Die cast aluminum body > Adjust volume via air pressure > Hermetically sealed diaphragms > Provide complete signaling coverage > Single or dual tone models > Effective range - 3/4 mile (1.2 km)* > 1 1/4" (32mm) NPT Inlet > Single or dual tone frequency > Operating range - 50 to 150 PSIG (3.5 to 10.5 kg/sq cm) Air Consumption Freq. db(c) db(c) Cu. Ft. /Sec. Net Description (Hz) at 10 ft. at 100 ft. (Liters/Sec.) Dimensions Weight K4-1 Single tone incorporating 4 K-1 Air " x 27" 36 lb Horns at 90 for 360 coverage with base (56) (685mm x 685mm) (16.3 kg) K4-12 Dual tone incorporating 4 K-12 Air 311/ " x 27" 62 lb Horns at 90 for 360 coverage with base (112) (685mm x 685mm) (28.1 kg) K4-25 Dual tone incorporating 4 K-25 Air 370/ " x 23" 55 lb Horns at 90 for 360 coverage with base (112) (584mm x 584mm) (24.9 kg) * Subject to environmental and geographical conditions, these models have a typical effective range of 3/4 mile (1.2 km) assuming an ambient background level of 60dB, a line pressure of 100 psi (7.03 kg/sq cm) and temperature of 60 F (15.6 C). Derated per FEMA 10 db per distance doubled. AIRCHIME is a registered trademark of Airchime Manufacturing Co. Ltd. 8-19

22 Edwards Warning Siren Accessories OUTDOOR WARNING SYSTEMS EWS-T1 EWS-CDP EWS-PMB SIREN CONTROL CENTERS Push button controls with up to 5 functions including test and cancel. EWS-SW-M Momentary Push Button EWS-SW Stop-start Push Button EWS-CL Clock Network EWS-T1 Timing Control EWS-CDP Civil Defense Control Center EWS-CDP-3 Civil Defense Control Center 3 Signal EWS-H-1 Siren Heater w/ Thermostat EWS-TAS-1 1 Function Telephone Activation System EWS-TAS-3 2 Function Telephone Activation System REMOTE CONTROL MAGNETIC MOTOR STARTERS EWS-MS-V1-3 for EWS-V1-3 and EWS-V2-3 Siren EWS-MS-V1-3-W for EWS-V1-3 and EDS-V2-3 Siren - Weatherproof EWS-MS-V1 for EWS-V1 Siren and EWS-V2 EWS-MS-V1-W for EWS-V1 Siren and EWS-V2 - Weatherproof EWS-MS-V3-3 for EWS-V3-3 Siren EWS-MS-V3-3-W for EWS-V3-3 Siren - Weatherproof EWS-MS-V3 for EWS-V3 Siren EWS-MS-V3-W for EWS-V3 Siren - Weatherproof EWS-MS-V4-3 for EWS-V4-3 & EWS-V5-3 Siren EWS-MS-V4-3-W for EWS-V4-3 & EWS-V5-3 Siren - Weatherproof EWS-MS-V4 for EWS-V4 EWS-V5 Siren EWS-MS-V4-W for EWS-V4 EWS-V5 Siren - W/P EWS-MS-V6-3 for EWS-V6-3 Siren EWS-MS-V6-3-W for EWS-V6-3 Siren - Weatherproof EWS-MS-V6 for EWS-V6 Siren EWS-MS-V6-W for EWS-V6 Siren - Weatherproof EWS-MS-V7-3 for EWS-V7-3 Siren EWS-MS-V7-3-W for EWS-V7-3 Siren - Weatherproof EWS-MS-V7 for EWS-V7 Siren EWS-MS-V7-W for EWS-V7 Siren - Weatherproof EWS-MS-V8-3-W for EWS-V8-3 Siren - Weatherproof RADIO CONTROL EQUIPMENT ENC-H ENC-D Hand Held Encoder Desk Mount Encoder UTILITY POLE MOUNTING BRACKETS Available in stainless steel or powder coat finish. EWS-PMB EWS-PMB-SS RADIO CONTROL EQUIPMENT EWS-RD1 EWS-RD2 EWS-RD3 EWS-RD1-DTMF EWS-RD2-DTMF EWS-RD1-DTMF EWS-RD1S EWS-RD2S EWS-RD3S EWS-RD1S-DTMF EWS-RD2S-DTMF EWS-RD3S-DTMF Pole Mount Bracket - Powder Coat Pole Mount Bracket - Stainless Steel One Function Radio Decoder 2 Tone Sequential Activation Two Function Radio Decoder 2 Tone Sequential Activation Three Function Radio Decoder 2Tone Sequential Activation One Function Radio Decoder with DTMF Activation Two Function Radio Decoder with DTMF Activation Three Function Radio Decoder with DTMF Activation One Function Radio Decoder with 2 Tone Sequential Activation and CTCSS Security Two Function Radio Decoder with 2 Tone Sequential Activation and CTCSS Security Three Function Radio Decoder with 2 Tone Sequential Activation and CTCSS Security One Function Radio Decoder with DTMF Activation and CTCSS Security Two Function Radio Decoder with DTMF Activation and CTCSS Security Three Function Radio Decoder with DTMF Activation and CTCSS Security REPLACEMENT DC PARTS EWS-DCAS-100 DC Activation Switch 100 Amp for EWS-V10 & EWS-11 EWS-DCAS-200 DC Activation Switch 200 Amp for EWS-V9 8-13

Vibratone Horns. Models 350 and 450

Vibratone Horns. Models 350 and 450 FEDERAL SIGNAL CORPORATION Vibratone Horns Models 350 and 450 DESIGNED FOR ROUTINE SIGNALING Range of up to 200 feet Coded or sustained tones Model 350 12, 24, 120 and 240VAC; Model 450 12, 24, 125 and

More information

C1D1 Explosion Proof Horn - Industrial Siren - Programmable Timer - NEMA 4X - Weatherproof

C1D1 Explosion Proof Horn - Industrial Siren - Programmable Timer - NEMA 4X - Weatherproof C1D1 Explosion Proof Horn - Industrial Siren - Programmable Timer - NEMA 4X - Weatherproof Part #: EPSN-HRN-PA-AT-MOD1 Made in the USA The Larson Electronics EPSN-HRN-PA-AT-MOD1 Explosion Proof Horn provides

More information

The Signal Is Clear TM

The Signal Is Clear TM P r o t e c t i n g y o u r b u s i n e s s The Signal Is Clear TM Federal Signal Hazardous Area Signaling Audible HORNS Corrosive atmospheres hazardous areas high noise extreme, temperatures dust humidity.

More information

Vibratone Horns. Models 350 and 450

Vibratone Horns. Models 350 and 450 FEDERAL SIGNAL CORPORATION Vibratone Horns Models 350 and 450 DESIGNED FOR ROUTINE SIGNALING Range of up to 200 feet Coded or sustained tones Model 350 12, 24, 120 and 240VAC; Model 450 12, 24, 125 and

More information

SIRENS PROGRAMMABLE MULTI-SOUND SIGNAL by Tomar Electronics

SIRENS PROGRAMMABLE MULTI-SOUND SIGNAL by Tomar Electronics by Tomar Electronics SIRENS POWER ALARM PROGRAMMABLE MULTI-SOUND INDUSTRIAL SIGNALS The POWER ALARM siren is a heavy duty industrial audible alarm designed to operate under adverse industrial conditions

More information

BID SPECIFICATIONS FOR (NAME OF ENTITY) COMMUNITY OUTDOOR WARNING SIRENS

BID SPECIFICATIONS FOR (NAME OF ENTITY) COMMUNITY OUTDOOR WARNING SIRENS BID SPECIFICATIONS FOR (NAME OF ENTITY) COMMUNITY OUTDOOR WARNING SIRENS (Name Of Entity) will be accepting bids for the purchase and installation of three (3) electronic, radio controlled, community outdoor

More information

Booster Compressors N Series. Pressures to 650 psig Capacities 9.5 to 724 cfm

Booster Compressors N Series. Pressures to 650 psig Capacities 9.5 to 724 cfm Booster Compressors N Series Pressures to 650 psig Capacities 9.5 to 724 cfm High Pressure Systems from Kaeser PET plastics, molding, leak testing and other special applications require higher pressures

More information

Compressed Air Dryers

Compressed Air Dryers The world s highest efficiency and heavy duty Desiccant at affordable prices Up to 300 SCFM Point of use dryers Supplement to a central system Zero air loss Applications: Sand Blasting Paint Spraying Dust

More information

DETCON MODEL AV2-C1D2C Hazardous Duty Class I. Div 2, Continuous Tone Alarm Station

DETCON MODEL AV2-C1D2C Hazardous Duty Class I. Div 2, Continuous Tone Alarm Station DETCON MODEL AV2-C1D2C Hazardous Duty Class I. Div 2, Continuous Tone Alarm Station Operator s Installation and Instruction Manual DETCON, Inc. 3200 Research Forest Dr., The Woodlands, Texas 77387 Ph.281.367.4100

More information

Explosion Proof Light Watt Metal Halide - Class 1 Div 1 & Class 2 Div 1

Explosion Proof Light Watt Metal Halide - Class 1 Div 1 & Class 2 Div 1 Explosion Proof Light - 400 Watt Metal Halide - Class 1 Div 1 & Class 2 Div 1 Part #: EPL-HB-400W-MH Made in the USA The EPL-HB-400W-MH metal halide, hazardous area light fixture from Larson Electronics

More information

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703 TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 DESCRIPTION These Sunline 2000 units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging.

More information

Description. Construction

Description. Construction LUH LUH PDS Horizontal Unit Heater 2.6 to 45 kw 208, 240, 277 480, 600 Volts Single or 3-Phase 8,900 to 153,600 BTU/Hour Wall or Ceiling Mounting Meets UL and CSA Requirements (600V CSA Certified Only)

More information

KUH. Horizontal Unit Heater. Applications. Description

KUH. Horizontal Unit Heater. Applications. Description KUH KUH PDS Horizontal Unit Heater 2.6 kw to 45 kw 208, 240, 277 480, 600 Volts Single or 3-Phase 8,900 to 153,600 BTU/Hour Wall or Ceiling Mounting Meets UL and CSA Requirements (600V CSA Certified Only)

More information

Coil-In-Tank Design: Refrigeration System: Cabinet Construction:

Coil-In-Tank Design: Refrigeration System: Cabinet Construction: Rite-Temp Manufacturing pioneered the development of refrigerated industrial water chillers in 1948. Since the first Rite-Temp units were introduced, quality engineering and manufacturing has been a key

More information

Electronic Siren Systems

Electronic Siren Systems Electronic Siren Systems Refinery warning Military mass alerting Industrial warning and evacuation Civil defence warning systems Flood / tsunami warning Golf course lightning warning Up to 150dB @ 1m 127dB

More information

DETCON MODEL SW-AV2-DV2 Hazardous Duty Class I. Div 2, Multi-tone Alarm Station

DETCON MODEL SW-AV2-DV2 Hazardous Duty Class I. Div 2, Multi-tone Alarm Station DETCON MODEL Hazardous Duty Class I. Div 2, Multi-tone Alarm Station Operator s Installation and Instruction Manual DETCON, Inc. 4055 Technology Forest Dr. Suite 100 The Woodlands, Texas 77387 Ph.281.367.4100

More information

Packaged Steam Fired Water Heater

Packaged Steam Fired Water Heater MODEL ST Packaged Steam Fired Water Heater Utilizes Steam To Heat Domestic Water, Semi-Instantaneous or Storage Type Heaters Features Reliable Packaged System Only high grade materials used in construction

More information

VWR symphony CO 2 INCUBATORS

VWR symphony CO 2 INCUBATORS VWR symphony CO 2 INCUBATORS Choice Stability Protection VWR symphony INCUBATORS THE CHOICE IS YOURS The VWR symphony series provides unsurpassed performance, reliability and selection. An enhanced and

More information

ASME Packaged Electric Water Heater

ASME Packaged Electric Water Heater MODEL SH & H ASME Packaged Electric Water Heater 15-1600 KW - All Voltages & Phases, 80-5000 Gallon Capacity Features Reliable Packaged System Only high grade materials used in construction to ensure long

More information

Industrial Horn & LED Strobe Warning System - 12V DC - Weatherproof - NEMA 4X - Class 1 Beacon

Industrial Horn & LED Strobe Warning System - 12V DC - Weatherproof - NEMA 4X - Class 1 Beacon Industrial Horn & LED Strobe Warning System - 12V DC - Weatherproof - NEMA 4X - Class 1 Beacon Part #: WAL-TL-1XCL1B-C-PA-12V Page: 1 Made in the USA The WAL-TL-1XCL1B-C-PA-12V from Larson Electronics

More information

Freezers. Laboratory & Plasma. i.series Horizon Series. Distinctly. Innovation can be beautiful.

Freezers. Laboratory & Plasma. i.series Horizon Series. Distinctly. Innovation can be beautiful. Innovation can be beautiful. Freezers Laboratory & Plasma Distinctly Freezers Laboratory & Plasma Precisely executed. Sharply designed. Helmer has provided high-quality laboratory equipment and refrigerated

More information

Hazardous Area Ringers & Loudspeakers

Hazardous Area Ringers & Loudspeakers G U A R D I A N T E L E C O M Product and Services Guide Hazardous Area Ringers & Loudspeakers Loudspeakers and Ringers that are designed and manufactured to meet the demands of Hazardous Areas where ignitable

More information

AEU1. Explosion-Proof Electric Air Heater For Hazardous Locations

AEU1. Explosion-Proof Electric Air Heater For Hazardous Locations AEU1 Explosion-Proof Electric Air Heater For Hazardous Locations 0518 II 2G, Ex d IIB T4 Gb IP55 (ATEX) Ex d IIB T4 Gb IP55 (IECEx) 1ExdIIBT4 X IP55 (EAC Ex) (Suitable for ATEX/IECEx/EAC Ex Zone 1 & 2)

More information

5 yr. Vitalite Rotating Warning Light. Models 121 and 121A LIGHT DUTY VEHICULAR LIGHT

5 yr. Vitalite Rotating Warning Light. Models 121 and 121A LIGHT DUTY VEHICULAR LIGHT FEDERAL SIGNAL CORPORATION Vitalite Rotating Warning Light Models 121 and 121A LIGHT DUTY VEHICULAR LIGHT Available in 12VDC and 24VDC Five dome colors 121 - Magnetic mount with cigarette lighter cord

More information

csw-200 intro d u c t i o n

csw-200 intro d u c t i o n csw-200 intro d u c t i o n The CSW-200-UL is The most popular of all swing gate operating systems in the country. It is designed with a non-scissor action arm that will greatly reduce the chance of injury.

More information

YOUR PROCESS DEMANDS THE MOST DEPENDABLE TEMPERATURE CONTROL UNIT AVAILABLE.

YOUR PROCESS DEMANDS THE MOST DEPENDABLE TEMPERATURE CONTROL UNIT AVAILABLE. Temperature Control Units Water & Oil 0-00 F Portable Chillers 0 - F Central Chillers Packages & Modules 0 - F Pump Tank Stations Chilled or Tower Water 00-0 gallons Cooling Tower Cells 4-40 tons Filters

More information

RQE Series Temperature Controllers

RQE Series Temperature Controllers RQE Series Temperature Controllers For more than 45 years, Thermal Care has manufactured industrial temperature control equipment with the best available component technologies. Our RQE Series mold temperature

More information

Specification/ Data Sheet

Specification/ Data Sheet Specification/ Data Sheet TRITON RP Agent Release Control Panel FEATURES Agent Release Control Panel designed specifically for suppression release operation with: Four initiating device circuits (IDCs)

More information

FUEL OIL DAY TANKS. SST Level Controller: UL 508 LISTED

FUEL OIL DAY TANKS. SST Level Controller: UL 508 LISTED FUEL OIL DAY TANKS SST Series - Engineering Submittal SST Series - Advanced Line Day Tanks Construction: UL 142 aboveground steel tank all seam welded, square, atmospheric tank of heavy gauge steel with

More information

Thermal Devices, Inc. Mount Airy, Maryland USA

Thermal Devices, Inc. Mount Airy, Maryland USA Unit Heater 2.6-50 kw 8,900 170,600 Btuh 208, 240, 277, 480, and 600 volt 1 or 3 phase Wall or Ceiling Mounted Canadian Standards Standards Description The Chromalox self-contained blower heater provides

More information

LARGE CAPACITY, REFRIGERATED COMPRESSED AIR DRYERS WITH TRUE-CYCLING TM OPERATION AND REDUNDANT OPERATING SYSTEMS. MultiPlex.

LARGE CAPACITY, REFRIGERATED COMPRESSED AIR DRYERS WITH TRUE-CYCLING TM OPERATION AND REDUNDANT OPERATING SYSTEMS. MultiPlex. INNOVATIVE COMPRESSED AIR SOLUTIONS LARGE CAPACITY, REFRIGERATED COMPRESSED AIR DRYERS WITH TRUE-CYCLING TM OPERATION AND REDUNDANT OPERATING SYSTEMS 3,200 19,200 scfm STAINLESS STEEL HEAT EXCHANGERS www.zeks.com

More information

MultiPlex INNOVATIVE COMPRESSED AIR SOLUTIONS LARGE CAPACITY TRUE-CYCLING TM REFRIGERATED COMPRESSED AIR DRYERS

MultiPlex INNOVATIVE COMPRESSED AIR SOLUTIONS LARGE CAPACITY TRUE-CYCLING TM REFRIGERATED COMPRESSED AIR DRYERS INNOVATIVE COMPRESSED AIR SOLUTIONS 3,250-19,200 SCFM Models Energy-Saving Operation Safeguard Against Air Treatment Failure: - Redundant Refrigeration Circuits - Redundant Electrical Circuits - Redundant

More information

Sioux E-Series. All-Electric Compact Industrial Steam Cleaners & Pressure Washers. Sioux E-Series All-Electric Steam Cleaners and Pressure Washers

Sioux E-Series. All-Electric Compact Industrial Steam Cleaners & Pressure Washers. Sioux E-Series All-Electric Steam Cleaners and Pressure Washers Sioux E-Series All-Electric Steam Cleaners and Pressure Washers Sioux E-Series All-Electric Compact Industrial Steam Cleaners & Pressure Washers Model E3.5HS3000 3 Consider Benefits... these Sioux s E-Series

More information

POWER TRANSFERS ACCESSORIES EAC. Manufacturer Product Product No. Product Description Item No.

POWER TRANSFERS ACCESSORIES EAC. Manufacturer Product Product No. Product Description Item No. POWER TRANSFERS 47 Keedex Cord K-DLA K-DLB Keedex 18 Flexible Cord; Product No. K-DLA; 1/4 flexible conduit; use door loops when you need to transfer electrical current from the door frame to the door;

More information

NH 3. Dual Discharge Evaporator. Ammonia Industrial Applications 1-16 Tons MDAN

NH 3. Dual Discharge Evaporator. Ammonia Industrial Applications 1-16 Tons MDAN NH 3 Dual Discharge Evaporator Ammonia Industrial Applications 1-16 Tons MDAN > > U s e d f o r S m a l l t o m e d i u m I n d u s t r i a l A m m o n i a a p p l i c a t i o n s Manufactured with Stainless

More information

C1D1 Explosion Proof 50W LED Flood Light Fixture - Paint Spray Booth Approved - Adj Surface Mount

C1D1 Explosion Proof 50W LED Flood Light Fixture - Paint Spray Booth Approved - Adj Surface Mount C1D1 Explosion Proof 50W LED Flood Light Fixture - Paint Spray Booth Approved - Adj Surface Mount Part #: EPL-LED-50W-RT-JB2 Page: 1 The Larson Electronics EPL-LED-50W-RT-JB2 Explosion Proof High Bay light

More information

Eclipse 8 & Eclipse NH

Eclipse 8 & Eclipse NH FEDERAL SIGNAL CORPORATION Eclipse 8 & Eclipse NH ELECTRO-MECHANICAL DC POWER SIRENS INSTALLATION AND OPERATING INSTRUCTIONS Copyright 2005 Federal Signal Corporation 255368B1 04/06 IMPORTANT NOTICE Federal

More information

High Capacity Instantaneous Steam Fired Water Heater

High Capacity Instantaneous Steam Fired Water Heater MODEL F High Capacity Instantaneous Steam Fired Water Heater Features Compact High Capacity Design Packaged System Water heater is factory assembled on an all welded steel mounting frame to save time and

More information

COMMON WORK RESULTS FOR ELECTRICAL: Basic Electrical Materials Methods

COMMON WORK RESULTS FOR ELECTRICAL: Basic Electrical Materials Methods 1. BASIC ELECTRICAL MATERIALS 1. All conduit and raceway must be 3/4" or larger. Exposed raceway in finished areas shall be in 700 or larger wiremold. Exception: runs to individual devices 10 or less,

More information

FIRE AND SAFETY. Manual Call Points p15-1 Magnetic Door Holders p15-3 Detection Cables p15-4 Portable Signals p15-7 Solar Powered Signals p

FIRE AND SAFETY. Manual Call Points p15-1 Magnetic Door Holders p15-3 Detection Cables p15-4 Portable Signals p15-7 Solar Powered Signals p FIRE AND SAFETY Manual Call Points p15-1 Magnetic Door Holders p15-3 Detection Cables p15-4 Portable Signals p15-7 Solar Powered Signals p15-10 Perth (08) 9248 0410 Sydney (02) 9676 1671 Melbourne (03)

More information

Centro-Matic Automated Lubrication Systems System Controls

Centro-Matic Automated Lubrication Systems System Controls Selecting the right controls for your automated lubrication system is one of the last steps in the design process. Several different models may be chosen to control power-operated pumps, depending on the

More information

DETCON MODEL SW-AV1-DV2 Hazardous Duty Class I. Div 2, Multi-tone Alarm Station

DETCON MODEL SW-AV1-DV2 Hazardous Duty Class I. Div 2, Multi-tone Alarm Station DETCON MODEL SW-AV1-DV2 Hazardous Duty Class I. Div 2, Multi-tone Alarm Station Operator s Installation and Instruction Manual Also covers the V2-DV2 dual strobe and A1-DV2 Horn units DETCON, Inc. 4500

More information

XGB Unit Heater. Certification. Model Coding XGB 038 T3B 3 1 T TEMPERATURE CODE T3B (165 C) T3A (180 C) T2D (215 C) T2C (230 C)

XGB Unit Heater. Certification. Model Coding XGB 038 T3B 3 1 T TEMPERATURE CODE T3B (165 C) T3A (180 C) T2D (215 C) T2C (230 C) The Norseman Series hazardous environment heater is designed to accommodate your requirements with flexibility and ease of maintenance, even under the toughest conditions. Norseman unit heaters are available

More information

Laboratory & Pharmacy Refrigerators

Laboratory & Pharmacy Refrigerators Innovation can be beautiful. Laboratory & Pharmacy Refrigerators Distinctly Laboratory & Pharmacy Refrigerators Precisely executed. Sharply designed. Helmer has provided high-quality laboratory equipment

More information

SENTRA Series Water Unit

SENTRA Series Water Unit SENTRA Series Water Unit Standard Unit: F to 0 F Process Fluid Temperatures* Optional High Temperature Configuration to 0 F Direct Injection Cooling 0 to kw Heaters to 7. HP Centrifugal Pumps (0-00 GPM)

More information

OIL-INJECTED ROTARY SCREW COMPRESSORS. GA 7-75 VSD+ (7-75 kw/ hp)

OIL-INJECTED ROTARY SCREW COMPRESSORS. GA 7-75 VSD+ (7-75 kw/ hp) OIL-INJECTED ROTARY SCREW COMPRESSORS GA - VSD (- kw/-0 hp) Innovative Atlas Copco has turned the compressed air industry on its head by redesigning the conventional layout of a typical air compressor.

More information

Screw Compressors SM SERIES. Capacities from: 16 to 54 cfm Pressures from: 80 to 217 psig

Screw Compressors SM SERIES. Capacities from: 16 to 54 cfm Pressures from: 80 to 217 psig Screw Compressors SM SERIES Capacities from: 16 to 54 cfm Pressures from: 80 to 217 psig Rotary Screw Compressor Maximum Reliability and Efficiency For years, customers have depended on Kaeser for reliable

More information

Mi-T-M carries a full line of portable heaters, built in the same quality tradition you ve come to expect from us.

Mi-T-M carries a full line of portable heaters, built in the same quality tradition you ve come to expect from us. Why Mi-T-M? Mi-T-M space heaters deliver powerful instant heat right where you need it. Whether you require heat for your workshop, job site or any other outdoor setting these portable units can be moved

More information

Industrial Air Heaters

Industrial Air Heaters HVH Horizontal or Vertical Discharge Fan Forced Unit Heater Industrial Air Heaters 2.6-50 kw 8,900 170,600 Btuh 208, 240, 277, 480, and 600 volt 1 or 3 phase Vertical or Horizontal Airflow Wall or Ceiling

More information

Comfort. Description. Applications

Comfort. Description. Applications Blower Heater 3-35 kw 10,00-119,40 Btuh 40 to 90 Volts, 50/0 Hz 31 Stainless Steel Case Shown 3 Phase ATEX, GOST, CE IIG Exd IIB T3 Description Type is designed to heat areas classified as hazardous locations

More information

C2D1/C1D2 Explosion Proof 50 Watt LED Light Fixture - Paint Spray Booth Approved - 6,250 Lumens

C2D1/C1D2 Explosion Proof 50 Watt LED Light Fixture - Paint Spray Booth Approved - 6,250 Lumens C2D1/C1D2 Explosion Proof 50 Watt LED Light Fixture - Paint Spray Booth Approved - 6,250 Lumens Part #: EPLC2-HB-50LED-RT Page: 1 The Larson Electronics EPLC2-HB-50LED-RT Explosion Proof High Bay light

More information

GTX Series Thermal Xchange Cycling Refrigeration Dryers GREAT LAKES AIR ANDARD ELECTRONIC DRAIN 5 -YEAR WARRANTY F PRESSURE DEWPOINT

GTX Series Thermal Xchange Cycling Refrigeration Dryers GREAT LAKES AIR ANDARD ELECTRONIC DRAIN 5 -YEAR WARRANTY F PRESSURE DEWPOINT GREAT LAKES AIR ANDARD ELECTRONIC DRAIN STANDARD ELECTRONIC 5 -YEAR WARRANTY 35-39 F PRESSURE DEWPOIN SS EXPANSION VALVE STANDARD ELECTRONIC DRAIN 35-39 F PRESSURE DEWPOINT GTX Series Thermal Xchange Cycling

More information

water to water heat pumps

water to water heat pumps AQUARIUS WW SERIES water to water heat pumps O ur Aquarius WW Series water-cooled modular reverse cycle chillers are designed to meet all your replacement or new construction chiller requirements. Specifically

More information

SP40S-D. Kingfisher Company, inc. Features: Description:

SP40S-D. Kingfisher Company, inc. Features: Description: Kingfisher Company, inc. SP40S-D Features: Multi-use applications The system can function as an evacuation system, an emergency messaging system, and an employee notification system Fire code applications

More information

1 6 Top Loading Refrigeration Catalog

1 6 Top Loading Refrigeration Catalog 2 0 1 6 Top Loading Refrigeration Catalog Sure Marine Service, Inc. 5320 28th Ave. N.W. Seattle, WA 98107 (800) 562-7797 (206) 784-9903 Shop Online: www.suremarineservice.com CB Series Top Loading Refrigerators

More information

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw) FALCON Rooftop Units ACPSE 50/60Hz Cooling : 36 to 1388 MBH (11 to 407 ) Heating : 40 to 1298 MBH (12 to 380 ) R Products that perform...by people who care NOMENCLATURE 6 AC P S E 435 P - HP G Q 6-60 Hz

More information

Electric Submersible Pumps

Electric Submersible Pumps Electric Submersible Pumps Versatile pumps with a wide variety of applications Construction Starts Here www.multiquip.com Electric Submersible Pumps Bolt-on discharge port allows easy replacement Cast

More information

JCseries EVAPORATIVE CONDENSER. engineering data

JCseries EVAPORATIVE CONDENSER. engineering data JCseries EVAPORATIVE CONDENSER engineering data Recold JC Series Evaporative Condenser Contents 2 Construction... 3 Schematic... 4 Engineering Data... 5 Selection Procedure... 6-9 Multi-Circuited Selection

More information

Posi-Drain. A non-clogging straight-through flow path design. Removes condensate, (oil and water) from compressed air systems.

Posi-Drain. A non-clogging straight-through flow path design. Removes condensate, (oil and water) from compressed air systems. Hydraulics Timer Drain Electric Operated Condensate Drain Posi-Drain A non-clogging straight-through flow path design. Removes condensate, (oil and water) from compressed air systems. Features Straight-through

More information

Dewatering Pumps. Construction Starts Here. Centrifugal and Diaphragm Models.

Dewatering Pumps. Construction Starts Here. Centrifugal and Diaphragm Models. Dewatering Pumps Centrifugal and Diaphragm Models Construction Starts Here www.multiquip.com Centrifugal Pumps Discharge port easily rotated 180 by removing four bolts. Tubular steel frame protects pump

More information

Packaged Semi-Instantaneous Steam Fired Water Heater

Packaged Semi-Instantaneous Steam Fired Water Heater MODEL STX Packaged Semi-Instantaneous Steam Fired Water Heater Shell and Tube Style Heater Features Reliable Only high grade materials used in construction to ensure long operating life Heat exchange pressure

More information

ASME Packaged Indirect Fired Water Heater

ASME Packaged Indirect Fired Water Heater Features Reliable Only high grade materials used in construction to ensure long operating life Hydrastone cement lining provides superior protection and tank longevity Heavy duty construction withstands

More information

MARK-COSTELLO WASTE STERILIZER SPECIFICATION SHEET

MARK-COSTELLO WASTE STERILIZER SPECIFICATION SHEET MARK-COSTELLO WASTE STERILIZER SPECIFICATION SHEET The Mark-Costello Waste Sterilzer is designed and manufactured in accordance with the following specifications: Vessel shall be built in accordance with

More information

Heating Systems. Brooders, Space Heaters and QuadRadiant Heaters

Heating Systems. Brooders, Space Heaters and QuadRadiant Heaters Heating Systems Brooders, Space Heaters and QuadRadiant Heaters Let s grow together. QUADRATHERM QuadRadiant Heater Patent Pending With Chore-Time s QUADRATHERM Heater, the Most Innovative Concept in Heating

More information

Class 1 Div 2 LED Pivoting Light - 2 foot 2 lamp - LED T series Style V Dimmable

Class 1 Div 2 LED Pivoting Light - 2 foot 2 lamp - LED T series Style V Dimmable Class 1 Div 2 LED Pivoting Light - 2 foot 2 lamp - LED T series Style - 0-10V Dimmable Part #: HAL-24-2L-LED-BMSW-D-V2 Page: 1 Made in the USA The Larson Electronics HAL-24-2L-LED-BMSW-D-V2 Hazardous Area

More information

EXH Series Explosionproof Electric Air Heaters

EXH Series Explosionproof Electric Air Heaters EXH Series Electric Air Heaters Cl. I, Div. & 2, Groups C, D Cl. II, Div., Groups E, F, G NEMA 7CD, 9EFG EXH explosionproof electric heaters are used: In areas made hazardous by the presence of flammable

More information

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data July 28, 2008 Page 1 1 of 3 PROJECT: TAG: Gross Cooling Capacity [Btuh]: 37,800* Design CFM: 1,200 Seasonal

More information

SAFEPATH SAFEPATH. Emergency communications system

SAFEPATH SAFEPATH. Emergency communications system SAFEPATH SAFEPATH Emergency communications system ALERiTY Integrated mass notification solutions by Eaton; designed to protect, alert and inform your most critical resources your people ALERiTY /a ler

More information

Semi-Instantaneous Indirect Fired Water Heater

Semi-Instantaneous Indirect Fired Water Heater MODEL BWX Semi-Instantaneous Indirect Fired Water Heater Use Boiler Water Or HTHW To Heat Domestic Water Features Reliable Only high grade materials used in construction to ensure long operating life Hydrastone

More information

CEILING FANS THE PREMIUM QUALITY LINE FROM COMMERCIAL/INDUSTRIAL & SPECIAL APPLICATION. World Leader in Ceiling Fan Systems

CEILING FANS THE PREMIUM QUALITY LINE FROM COMMERCIAL/INDUSTRIAL & SPECIAL APPLICATION. World Leader in Ceiling Fan Systems THE PREMIUM QUALITY LINE FROM COMMERCIAL/INDUSTRIAL & SPECIAL APPLICATION CEILING FANS World Leader in Ceiling Fan Systems Visit our website at: www.marleymep.com Only Leading Edge Offers These Exclusive

More information

13 GEP A L P - 1 A

13 GEP A L P - 1 A PRODUCT SPECIFICATIONS PACKAGED GAS / ELECTRIC 3GEP MERIT SERIES Residential - R-40A Bulletin No. 20602 December 202 Supersedes October 202 SEER - 3.00 AFUE - 80% 2 to 5 Tons Cooling Capacity - 22,800

More information

Your Climate. We're There. TM: MDB B 2140B. Ducted Split Systems. Models: MDB 075B - MDB750B MDB 075B/B - MDB500BR. Air Conditioning REGISTERED

Your Climate. We're There. TM: MDB B 2140B. Ducted Split Systems. Models: MDB 075B - MDB750B MDB 075B/B - MDB500BR. Air Conditioning REGISTERED Your Climate. We're There. TM: MDB B 2140B Ducted Split Systems Models: MDB 075B - MDB750B MDB 075B/B - MDB500BR REGISTERED Air Conditioning Contents Nomenclature System... 2 Features... 2 General Specifications...3-5

More information

DETCON MODEL AV1/AV2-C1D2M Hazardous Duty Class I. Div 2, Multitone Alarm Station

DETCON MODEL AV1/AV2-C1D2M Hazardous Duty Class I. Div 2, Multitone Alarm Station DETCON MODEL AV1/AV2-C1D2M Hazardous Duty Class I. Div 2, Multitone Alarm Station Operator s Installation and Instruction Manual DETCON, Inc. 3200 Research Forest Dr, The Woodlands, Texas 77387 Ph.281.367.4100

More information

CENTRAL SPLIT UNIT UNIC

CENTRAL SPLIT UNIT UNIC CENTRAL SPLIT UNIT UNIC sal is equipped to produce a wide range of COOLER Air conditioning and Refrigeration units, conforming to the international standards and works continually to improve its products

More information

Screw Compressors AS SERIES. Capacities from: 59 to 124 cfm Pressures from: 80 to 217 psig

Screw Compressors AS SERIES. Capacities from: 59 to 124 cfm Pressures from: 80 to 217 psig Screw Compressors AS SERIES Capacities from: 59 to 124 cfm Pressures from: 80 to 217 psig Rotary Screw Compressor Maximum Reliability and Efficiency For years, customers have relied on Kaeser for reliable

More information

Mounting Kits. LWMB2 6" 6 3 /8" 5 7 /8" 2.6 lbs lbs. LCMB2 6" 5" 5 3 /4 2.3 lbs. 2.5 lbs.

Mounting Kits. LWMB2 6 6 3 /8 5 7 /8 2.6 lbs lbs. LCMB2 6 5 5 3 /4 2.3 lbs. 2.5 lbs. FEDERAL SIGNAL CORPORATION Mounting Kits Models LWMB2 and LCMB2 CUSTOM MOUNTING BRACKETS Heavy-duty construction Easy installation For walls and outside corners Indoor and outdoor use Replaces unsightly

More information

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes). Guide Specifications PART 1 GENERAL 1.01 SYSTEM DESCRIPTION Microprocessor controlled, air-cooled liquid chiller utilizing scroll compressors, low sound fans, hydronic pump system and optional fluid storage

More information

3500 CFM TECHNICAL SPECIFICATIONS MIDWEST VACUPAC BIN VENT AND CONVEYOR TRANSFER POINT DUST CONTROL SYSTEM SERIES MBV 43 F MBV 43 C MBV 37 C MBV 54 F

3500 CFM TECHNICAL SPECIFICATIONS MIDWEST VACUPAC BIN VENT AND CONVEYOR TRANSFER POINT DUST CONTROL SYSTEM SERIES MBV 43 F MBV 43 C MBV 37 C MBV 54 F 3500 CFM MBV 37 C *MBV MBV 43 C MBV 54 C MBV 37 F MBV 43 F MBV 54 F TECHNICAL SPECIFICATIONS MIDWEST VACUPAC BIN VENT AND CONVEYOR TRANSFER POINT DUST CONTROL SYSTEM MBV SERIES TECHNICAL SPECIFICATIONS

More information

T15 Product Guide UNCOMPROMISED INDUSTRIAL-STRENGTH PERFORMANCE TO CLEAN BOTH OPEN AREAS AND TIGHT SPOTS PRODUCT HIGHLIGHTS KEY PRODUCT ENHANCEMENTS

T15 Product Guide UNCOMPROMISED INDUSTRIAL-STRENGTH PERFORMANCE TO CLEAN BOTH OPEN AREAS AND TIGHT SPOTS PRODUCT HIGHLIGHTS KEY PRODUCT ENHANCEMENTS UNCOMPROMISED INDUSTRIAL-STRENGTH PERFORMANCE TO CLEAN BOTH OPEN AREAS AND TIGHT SPOTS PRODUCT HIGHLIGHTS Built on the success of Tennant s small industrial battery riders; this next generation scrubber

More information

next generation R 1 cycling refrigerated compressed air dryers flow capacity: scfm ( Nm 3 /hr)

next generation R 1 cycling refrigerated compressed air dryers flow capacity: scfm ( Nm 3 /hr) next generation R 1 cycling refrigerated compressed air dryers flow capacity: 20-2000 scfm (32-3210 Nm 3 /hr) cycling refrigerated compressed air dryers R 1 flow capacity: 20-2000 scfm (32-3210 Nm 3 /hr)

More information

ECONOBOOST EB II & EB III Compact Water Booster

ECONOBOOST EB II & EB III Compact Water Booster ECONOBOOST EB II & EB III Compact Water Booster The Stokvis EB II twin pump & EB III triple pump cold water booster units meet today s need for compact, reliable, high performance equipment with modest

More information

SPECIFICATION MICROMIST FIRE SUPPRESSION SYSTEM WITH SHP-PRO CONTROL PANEL

SPECIFICATION MICROMIST FIRE SUPPRESSION SYSTEM WITH SHP-PRO CONTROL PANEL SECTION 1 - GENERAL CONDITIONS I. SCOPE: This specification outlines the requirements for a Fike Micromist Water Mist Fire Suppression System with automatic detection and control. The work described in

More information

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811 Description These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of Refrigerant R-410A for storage

More information

NON-CYCLING REFRIGERATED AIR DRYERS. GSRN Series

NON-CYCLING REFRIGERATED AIR DRYERS. GSRN Series NON-CYCLING REFRIGERATED AIR DRYERS GSRN Series GARDNER DENVER GSRN REFRIGERATED AIR DRYERS Why Dry Compressed Air? Compressed air has long been described as the fourth utility after electricity, natural

More information

OIL-INJECTED ROTARY SCREW COMPRESSORS. GA 7-37 VSD+ (7-37 kw/10-50 hp)

OIL-INJECTED ROTARY SCREW COMPRESSORS. GA 7-37 VSD+ (7-37 kw/10-50 hp) OIL-INJECTED ROTARY SCREW COMPRESSORS GA - VSD+ (- kw/- hp) Small compressor, big ideas Atlas Copco has turned the compressed air industry on its head by redesigning the conventional layout of a typical

More information

WELD STRONG BREATHE FREE

WELD STRONG BREATHE FREE WELD STRONG BREATHE FREE REVISED 03/01/2017 FUME EXTRACTORS THAT WORK AS HARD AS YOU DO Welding and metal fabricating can be tough, dirty jobs. But they should never be unsafe. Protecting workers from

More information

Hazardous Location LED Pivoting Light - C1D2 - Dimmable - Modbus TCP/IP Network - Meets USCG Specs

Hazardous Location LED Pivoting Light - C1D2 - Dimmable - Modbus TCP/IP Network - Meets USCG Specs Hazardous Location LED Pivoting Light - C1D2 - Dimmable - Modbus TCP/IP Network - Meets USCG Specs Part #: HALP-ANC-48-2L-LED-D-V2 Page: 1 Made in the USA The Larson Electronics HALP-ANC-48-2L-LED-D-V2

More information

Call us today! (800)

Call us today! (800) 150 TON AIR-COOLED CHILLER PA-ACCTR-150 Call us today! (800)341-4297 The 150-Ton portable chiller package features a Trane RTAC chiller unit. Trane leads the industry in providing some of the most reliable,

More information

Shipboard Electric Water Heater

Shipboard Electric Water Heater Marine Products Division Model MSE Shipboard Electric Water Heater 6-119 Gallon Capacity, Three Phase Voltages Up To 58 KW, Single Phase Voltages ver 6 KW Heavy Duty Construction n Hydrastone cement lining

More information

Plate Water Heaters Brazed Plate Water Heaters-BPH Series Plate and Frame Water Heaters-PFH Series

Plate Water Heaters Brazed Plate Water Heaters-BPH Series Plate and Frame Water Heaters-PFH Series Plate Water Heaters Brazed Plate Water Heaters-BPH Series Plate and Frame Water Heaters-PFH Series Designed to be used with condensing boilers. Increase the boiler efficiency by allowing condensing boilers

More information

Applications. Standard Materials

Applications. Standard Materials Mercmaster III Low Profile Compact Fluorescent Luminaires Compact Fluorescent listed for simultaneous exposure to combustible dusts and flammable gases or vapors. Applications Enclosed and gasketed fixtures

More information

HUH2. Hydronic Unit Heater CRN: 0H C 400 psig (2758 KPa) Industrial Grade Heat-Exchanger Unit Heaters

HUH2.   Hydronic Unit Heater CRN: 0H C 400 psig (2758 KPa) Industrial Grade Heat-Exchanger Unit Heaters Available with reversible core connection feature! HUH2 36 inch fan size model now available! Hydronic Unit Heater CRN: 0H14933.2C 400 psig (2758 KPa) Industrial Grade Heat-Exchanger Unit Heaters www.hazlocheaters.com

More information

Versatile new products for multiple applications and specialty conditions. New Products Catalog

Versatile new products for multiple applications and specialty conditions. New Products Catalog Versatile new products for multiple applications and specialty conditions New Products Catalog LARGE CAPACITY STAINLESS STEEL BUILT-IN UNDER COUNTER Perfect for laboratories, satellite pharmacies, nursing

More information

Explosion-Proof Forced Air Unit Heater - XGB

Explosion-Proof Forced Air Unit Heater - XGB Explosion-Proof Forced Air Unit Heater - XGB The XGB Series hazardous environment heater is designed to accommodate your requirements with flexibility and ease of maintenance, even under the toughest conditions.

More information

Freezers. Laboratory & Plasma. i.series Horizon Series

Freezers. Laboratory & Plasma. i.series Horizon Series Freezers Laboratory & Plasma Laboratory & Plasma Freezers Precisely executed. Sharply designed. Helmer has provided high-quality laboratory equipment and refrigerated products for over 30 years. Our experience

More information

DIESEL Engine Fire Pump Controllers Features

DIESEL Engine Fire Pump Controllers Features September 007 DIESEL Engine Fire Pump Controllers Features FD0 Diesel Engine Controllers 1-1 Printer / Recorder The industrial grade thermal printer is housed in a rugged steel enclosure within the controller.

More information

NEW INTELLIGENT AIR TECHNOLOGY

NEW INTELLIGENT AIR TECHNOLOGY L Series L07 L11 (10 15 HP) Rotary Screw Compressors NEW INTELLIGENT AIR TECHNOLOGY L07 L11 ROTARY SCREW COMPRESSORS The L Series oil injected rotary screw compressors provide a range that combines high

More information

50W Explosion Proof Trunnion Mount Compact LED Flood Light - C1D2, C2D1 - Paint Spray Booth Approved

50W Explosion Proof Trunnion Mount Compact LED Flood Light - C1D2, C2D1 - Paint Spray Booth Approved 50W Explosion Proof Trunnion Mount Compact LED Flood Light - C1D2, C2D1 - Paint Spray Booth Approved Part #: EPLC2-TRN-50LED-RT Page: 1 The Larson Electronics EPLC2-TRN-50LED-RT Explosion Proof compact

More information

Reciprocating Simplex and Duplex Tank Mount Compressor Systems Rev. 08/23/12

Reciprocating Simplex and Duplex Tank Mount Compressor Systems Rev. 08/23/12 Reciprocating Simplex and Duplex Tank Mount Compressor Systems Rev. 08/23/12 GENERAL The Powerex oil-less tank mounted system is designed to provide clean, dry air for industrial applications where the

More information

IN THE MARINE INDUSTRY

IN THE MARINE INDUSTRY H E A T E X C H A N G E R S BULLETIN NO. TIS-108A PRIME SURFACE HEAT EXCHANGERS PLATE & FRAME HEAT EXCHANGERS ALL-WELDED PLATE HEAT EXCHANGERS IN THE MARINE INDUSTRY THE heat transfer people H E A T E

More information