X16PDM P R O G RAMMABLE

Size: px
Start display at page:

Download "X16PDM P R O G RAMMABLE"

Transcription

1 S E R I E S XPDM P R O G RAMMABLE D I G I T A L M O N I T O R S E N G I N E E R I N G C O M P A N Y

2 The Ronan Series XPDM Programmable Digital Monitors are the latest generation of Ronan s state-of-the-art digital input man machine interface and remote annunciators offered in most common mechanical configurations. The systems in the XPDM Programmable Digital Monitors feature high density input field contact capacity with remote indicator light output. A system common trouble and a per-point auxiliary relay output may be utilized for field contact repeater or for remote group alarms. The system monitors internal routines and the communication backbone, signaled by dedicated LED or relay contact closure. XPDM is equipped with a host interface module that provides advanced communication interface protocols to interface with an external host computer, local network, or plant network. F E A T U R E S INPUT Dry Contact System Powered Vdc ly Open/ly Closed Live Contacts (Isolated) Vdc, Vdc, Vdc or Vac, 0 Vac SEQUEE All Standard ISA s User Configurable OUTPUTS Dual Configurable Auxiliary Contact Double Throw Selectable ly Energized or De-energized GP or HS Relays May be Added in the Field Common System Trouble Alarm Reflash System Trouble Alarm Serial Alarm Output Protocol Ronan Proprietary MODBUS RTU Slave TCP/IP DNP.0 Alarm Serial Interface Object Link Embedded for Control (OPC) DESIGN TECHLOGY Microprocessor Based High Noise Immunity Field Proven Off-the-shelf Worldwide Serial Input/Output Comprehensive User Configuration with Standard Windows Software MECHANICAL Relay Rack and Surface Mounting Light Weight Reinforced Terminal Block W ARRANTY Three () Years APPROVALS UL Underwriters Laboratories CE Cenelec CUL Canadian Underwriters Labortories

3 P P V+ V- G FUSE PWR PROGRAMMABLE DIGITAL MONITORS/Digital Input to Serial Output The Ronan XPDM Programmable Digital Monitor Systems are designed for the needs of the process and power industries where field inputs and electronics are required to be some distance away from the display or indicating lamp cabinets, such as Relay Rack Room from Control Room, using multiconductor lamp cabinet cables. The systems provide all the basic features of an annunciator in a small, high density module chassis. A system common trouble alarm and a per-point auxiliary relay output may be utilized for a field contact repeater or for remote group alarms. The per-point optional auxiliary relay module, equipped with one to four relays, provides a selectable form A or B type dry contact. A system common reflash output allows remote annunciation of any window going into alarm. Similar to the XCA Window Annunciator, the Programmable Digital Monitor provides serial output of alarms in many industry standard protocols to Host computers, Human Machine Interface (HMI) computers, PLCS and DCS. SURFACE-MOUNT REMOTE LOGIC CHASSIS The Ronan XPDM-SM Surface-mount Remote Logic Chassis are designed in two sizes of point and point logic inputs. The chassis is used to mount in NEMA enclosures with standard termination facility of Weidmueller or custom termination of various industry standard terminal blocks. The system is interfaced to HMI computers through its serial output using industry standard OPC interface via the Host interface module. The system can also interface to one of many types of Ronan lamp cabinets or mosaic cabinets through multiconductor lamp cables or individual wires. The system is widely used in applications where field contact status is to be displayed on graphic displays operating in a door mounted industrial computer, or a visual lamp cabinet mounted on the door of the enclosure. A Overall B Cutout.0" (. mm) XPDM." (. mm) JA 0 JB.00" (0.0 mm) Optional Elco Connector 0." (. mm) Dia. 0." (. mm) A Overall B Cutout Model Inches mm Inches mm XPDM-SM- ALM.0... XPDM-SM- ALM

4 FUSE PWR XPDM PROGRAMMABLE DIGITAL MONITORS/Digital Input to Serial Output RACK-MOUNT REMOTE LOGIC The Ronan XPDM-RR Rack-mount Remote Logic Chassis are designed for standard.00 inch (.0 mm) or.00 inch (0.0 mm) relay rack mounting. Field inputs and remote lamp outputs are accessed from the rear of the chassis via a multipin Elco connector or standard terminal block. The system is used for high density alarm input monitoring in power plants with remote lamp cabinet connection. The system provides a serial output, daisy-chainable to a host device, using industry standard communication protocols. 0." (. mm) Dia. Optional Elco Connector." (. mm)." (. mm).".0 mm).00" (.0 mm)." (. mm)." (0. mm) Filter Module MODEL XPDM-SM WIRING To Another XPDM-J FUSE PWR P P V+ V- G JA XPDM JB 0 Live Dry Test Silence Ack Reset First Out Reset GP GP To Host RS RS (+) Vdc ( ) Power Supply or DC to DC Converter V+ XCA-IM A TEST A SIL TO CTA ACK RFL RST RAN FRST GP A COM GP TX+ TX- A COM P GND RS RX+ RX- CTA COM RFL COM PRGM RUN P RS RUN COM GND V- V+ P P P RXD TXD RXD TXD ERROR RUN XCA-IM * ** AC Horn Horn Horn Electronic Horn To Power as Required.0" (. mm) H(+) N( ) G Vac or Vdc Communication Cable

5 XPDM XPDM REMOTE ANNUIATOR SYSTEMS Multiconductor Cable or FC Wire Field Terminal Assembly XPDM-SM XCA-IM Human Machine Interface Multiconductor Cable or Multiconductor Cable or Wire Wire FC Field Terminal Assembly XPDM-RR XCA-IM Serial Alarm Output Lamp Box FC XPDM-SM Serial Alarm Output Multiconductor Cable or Wire XCA-IM Inlay or Mosaic Graphic MODEL XPDM-RR WIRING JA Notes for XPDM-SM/XPDM-RR: (H) Field Contact Voltage for Dry Contact or Live Input (FC) Field Contact Return (ME) Connect All First Out Windows in a Group (AL) Open Collector Transmitter Output for Lamp JA, JB: Mimic Lamp Outputs Notes for XCA-IM: TO: A, A, CTA, RFL RUN for Transistor Driver* A, A, CTA, RFL, RUN for Auxiliary Output** JB Live Dry + 0 : ly Opened To Another COM: Common XPDM-J : ly Closed A: Horn A: Horn CTA: Common Trouble Alarm RFL: Reflash RUN: XCA-IM Power Indication GP, GP: Programmable Inhibit Function 0 J J V+ V G Communication Cable (H)A (FC)A (H)B (FC)B (H)C (FC)C (H)D (FC)D (ME)A 0 (ME)B (ME)C (ME)D (AL)A (AL)B (AL)C (AL)D Test Silence Ack Reset First Out Reset GP GP To Host RS RS Wiring Detail GND V- V+ V+ TEST SIL ACK RST FRST GP GP TX+ TX- GND RX+ RX- PRGM P RS P P RS P XCA-IM RUN P RXD TXD RXD TXD ERROR RUN XCA-IM H(+) N( ) G A A TO CTA RFL RAN A COM A COM CTA COM RFL COM RUN COM (+) Vdc ( ) Power Supply or DC to DC Converter Vac or Vdc * ** AC Horn Horn Horn Electronic Horn To Power as Required

6 SEQUEE DIAGRAMS Return to Off First to Reset while Off To Acknowledge while Subsequent to or Subsequent Alarm or Acknowledged Acknowledge or Alarm Fast Flashing On Flashing First Out Reset while Subsequent Acknowledged On Acknowledge while First Out Reset or First Acknowledged Flashing Acknowledge or First Alarm Intermittent Flashing SEQUEE M Manual Reset Acknowledge, Reset and Test Push Buttons Alarm Device Lock-in Momentary Alarms Until Acknowledged The Device is Silenced and Flashing Stops when Acknowledged Manual Reset of Acknowledged Alarm Indications after Conditions Return to Operational Test SEQUEE FA Automatic Reset First Out Reset with First Out Flashing and Reset Push Button Acknowledge First Out Reset and Test Push Buttons Alarm Device Lock-in of Momentary Alarms until Acknowledged First Out Flashing Different from Subsequent Flashing First Out Reset Push Button to Change the First Out Indication to be the Same as Subsequent Indications Automatic Reset of Acknowledged Alarm Indications when Conditions Return to Operational Test Alarm Ringback Reset RingBack Slow Flashing Alarm Ringback Off Acknowledge while Return to To Alarm Ringback or Alarm Fast Flashing Basic Option Key Words Number Letter Key Words A Automatic Reset Silence Push Button M Manual Reset Silence Interlock R Ringback First Out Reset Interlock No Lock-in No Flashing No Automatic Alarm Silence Common Ringback Automatic Ringback Silence First Out Option Key Words Designation Number Key Words F No Subsequent Alarm State 0 No Ringback F No Subsequent Common Ringback Alarm Flashing F First Out Flashing and Automatic Momentary Reset Push Button Ringback Dim Lamp Monitor Lamp Test Return to Alarm Ringback Acknowledge On Acknowledge while SEQUEE R Ringback Acknowledge, Reset and Test Push Buttons Alarm and Ringback Devices Lock-in of Momentary Alarms until Acknowledged The Device is Silenced and Fast Flashing Stops when Acknowledged Ringback and Indications when Conditions Return to Manual Reset of Ringback Indications Operational Test

7 XPDM MODULES HOST INTERFACE MODULE The Model XCA-IM Interface Module connects the XPDM Programmable Digital Monitor Remote Logic Annunciator with external host devices. Hosts can be a DCS, PLC, or plant computer. An isolated RS or a 0 Base T network connection is used with the most common industry accepted communication standards such as MODBUS, DF, and TCP/IP protocols for host communication.." (. mm)." (.0 mm).00" (.0 mm).00" (.0 mm) V+ XCA-IM A TEST A SIL TO CTA ACK RFL RST RAN FRST GP A COM GP TX+ TX- A COM P GND RS RX+ RX- CTA COM RFL COM PRGM RUN P RS RUN COM GND V- V+ P P P RXD TXD RXD TXD ERROR RUN." (. mm) 0." (.0 mm) Dia. The Module provides a number of special features such as timestamped event archive, common trouble alarm, dual horn output, reflash output, and system diagnostic output. All outputs are provided in the form of an open collector transistor and selectable Form C dry contact. Additional on-board LEDs are designed to indicate serial communication and system status. ALARM SEQUEE/DISPLAY MODULE The Ronan Model XPDM is designed with all sequences available internal to each module, allowing for field programmable selections of all commonly used ISA sequences through a computer or laptop using simple graphical user interface entry. Selection of field contact polarity is allowed through the on board jumpers for each channel. Each alarm/display combination module contains a single, dual, triple, or quad alarm channel with its associated dual lamp or LED displays. The modules are removable from the front without interfering with the remaining modules. AUXILIARY CONTACT MODULE The Auxiliary Contact Module is available for the XPDM Annunciator with single, dual, triple, or quad relay circuit, according to the density selection. The modules plug in from the front of the system. Each relay provides for a form A or B type contact, normally open or normally closed, and normally energized or normally not energized, and is selectable by a jumper switch.

8 CONFIGURATION XPDM-CONFIGNT The Ronan XPDM Programmable Digital Monitors are configured fully with the use of a Windows graphical user interface application operating in a Windows environment on a PC or Laptop through an RS serial connection to the XCA-IM interface module. The application allows for factory or field programmability of all features for each window. Configuration data is saved in non-volatile memory on-board each module. Selections such as alarm sequence, first out grouping, operational or lamp test, output signals follow alarm or field contact, time delay and special functions are all set through the configuration application software.

9 HMI/MMI (Human and Man Machine Interface) GRAPHIC MONITORING APPLICATION SOFTWARE Ronan XPDM easily interfaces with all common industry display software such as Wonderware, RS View, Intellusions, etc. Ronan provides the XPDM System with HMI/MMI software and hardware for all monitoring requirements of state-of-the-art installations. Ronan provides OPC configuration software of graphics and object tagging, all based on process or plant requirement. The system easily adapts to a graphics CRT based annunciator for special annunciator applications. Computer Hardware Options: Standard PCs Hardened Industrial PCs Dust and Moisture Proof Touch Screen Systems Wonderware is a trademark of Invensys Systems, Inc. RS View is a trademark of Rockville Automation Intellusions is a trademark of Emerson Typical Graphical User Interfaces

10 FUSE PWR COMMUNICATION / PROTOCOLS The Ronan XPDM Programmable Digital Monitors have comprehensive serial alarm communication facilities to interface to Host machines and transfer field input status to, or receive alarm data from PLCs, DCSs, Network Alarm Servers and Computers. MODBUS RTU SLAVE The MODBUS RTU Slave protocol allows users of PLCs and DCSs that are operating as MODBUS Masters to periodically acquire the status of annunciator inputs or transmit alarms to the annunciator for process monitoring. Status of the annunciator is continuously updated in a pre-defined Memory Register Map complying to the MODBUS protocol. The Host (MODBUS Master) periodically reads or writes to the Memory Register Map serially using pre-defined MODBUS command sets. The data is then used for process monitoring. Events XPDM XCA-IM DCS, PLC or Computer ALLEN BRADLEY DF INTERFACE The Allen Bradley DF protocol allows users of AB PLCs to periodically acquire or transmit alarm data to or from the annunciator for monitoring and control. The input status is periodically transmitted as a bitmap complying to the DF protocol. The PLC provides an open serial port to send or receive the bitmap status. 0

11 FUSE PWR FUSE PWR NETWORK TCP/IP Transport Control Protocol/Internet Protocol (TCP/IP) The Ronan XPDM provides as an optional connection using the XCA-IM interface module and XCA-NM network converter module to a local or plant network. The input alarm status is transmitted or received via TCP/IP at speeds of up to 0 MB all across the network. Typical TCP/IP Address Base T Ethernet 0 Base T XPDM XCA-IM XCA-NM Network Hub Other Network Device Plant Network RONAN PROPRIETARY (Alarm/) The XPDM provides features to serially transmit input alarm status to external host devices through XCA-IM. This feature can be used to transfer input alarm status serially to Ronan s X0 Serial Annunciator for remote visual annunciation display. Lamp Box Lamp Box XPDM XCA-IM X0-A X0-B Events RS/RS

12 FUSE PWR FUSE PWR COMMUNICATION / PROTOCOLS OPC INTERFACE (Object Link Embedded for Control) OPC is designed to allow client applications access to alarm input status of a system in a consistent manner. With wide industry acceptance, OPC provides easy integration into the common Human Machine Interface (HMI) applications widely used in the process industry. OPC Client OPC Client Local OPC Server Ronan OPC Interface Driver Ethernet Network OPC Server XCA-NM Ronan OPC Driver OPC Interface Typical TCP/IP Address..0. XCA-IM XPDM TYPICAL APPLICATION The XPDMs feature an optional bit Windows NT driver and mechanisms for OPC clients to be notified of the occurrences of specified events and alarm conditions. They also provide services which allow OPC clients to determine the events and conditions supported by an OPC server, and to obtain their current status. Graphics OPC Client Typical TCP/IP Address..0. Computer with HMI Interface OPC Server XCA-NM XCA-IM XPDM Plant Ethernet Network

13 SPECIFICATIONS/POWER REQUIREMENTS System Voltage: Lamps, Logic Vdc ± 0% Field Contacts Vdc, Vdc, Vdc, Vac, or 0 Vac Power Source (System External): Power Supply Vac 0/0 Hz; 0 Vac 0/0 Hz Converter Vdc, Vdc, or Vdc Temperature Range: Operating 0 to 0 C ( to 0 F) Storage -0 to + C (-0 to + F) Inputs: Contact Dry or Live; ly Open / ly Closed Field Selectable Interrogation Voltage Vdc, Vdc, Vdc, Vac, or 0 Vac Response Time: 0 Milliseconds EMI/RFI Capability: CE Compliant Outputs: Fast Flash, Slow Flash, Steady ON, Intermittent Fast Flash Dual, Selectable by Cabinet Module Auxiliary Relays Form C, Selectable Form A or B; ly Not Energized or ly Energized Contact Rating General Purpose: Vdc; 0. Vac Common System Trouble: Form C, Vdc; 0. Vac Open Collector Transistor Output 00 Vdc Common System Reflash: Form C, Vdc; 0. Vac Open Collector Transistor Output 00 Vdc Controls: Momentary Push Button: Integral or Remote; Single Pole ly Open; +V Switched; Silence; Acknowledge; Reset, Test, GP, GP Diagnostic: System Trouble Alarm (RUN) - Form C, Vdc; 0. Vac System Trouble Alarm (RUN) - Indicating LED Green Communication Diagnostic (ERROR) - Indicating LED Red Transmit/Receiver LED Pair Communications: Serial - RS (P) to External Host Network - RJ (TCP/IP) to External Host Serial Protocols: MODBUS RTU, Allen Bradley, DF, DNP.0, Ronan Proprietary Network Protocols: TCP/IP (OPC) Serial: RS (P) - System and Option Programming via Laptop or Computer Software - Ronan XCA Configuration Special Feature: Alarm Time Stamping Alarm Storage - 00 Alarms GP, GP - Special Function Push-button Interface To specify the correct power supply, count the number of alarm modules you need to power from the supply. Calculate the total requirement as follows: Total Watts = No. of Modules x F(Factor + F Aux.) + P(IM) Model F Module F Aux. Relay Adder P(IM) XPDM W W 0W Match the total wattage with the next higher power rating of the Power Supply or Converter listed. DC/DC Converters Model - Power Failure, Circuit Breaker, Power ON Light, Diode Gated - / - 0 SCP - / - 00 SCP - / - 00 SCP - / - 0 SCP - / - 00 SCP - / - 00 SCP Power Output Watts DC Voltage Out DC Voltage In AC Voltage In DC Voltage Out Power Output Watts Diode Grated Output AC/DC Power Supplies / - - / / - - / / DA - - DA DA - - 0DA

14 ORDERING INFORMATION XPDM PROGRAMMABLE DIGITAL MONITORS Logic Chassis (Rack-mount/Surface-mount) XPDM-RR--T XPDM-RR--TE XPDM-SM--T XPDM-SM--TE XPDM-SM--T XPDM-SM--TE Module ( Points Maximum without Auxiliary Contacts/ Points with Auxiliary Contacts), Terminals Only Module ( Points Maximum without Auxiliary/ Points with Auxiliary Contacts), Elco Connector for Lamp Driver Module ( Points without Auxiliary Contacts/ Points with Auxiliary Contacts), Terminals Only Module ( Points without Auxiliary Contacts/ Points with Auxiliary Contacts), Elco Connector for Lamp Driver Module ( Points without Auxiliary Contacts/ Points with Auxiliary Contacts), Terminals Only Module ( Points without Auxiliary Contacts/ Points with Auxiliary Contacts), Elco Connector for Lamp Driver Notes:. Each XIPDM Chassis will require an XCA-IM Interface Module.. For Auxiliary Module selection, refer to XCA Literature. Use Quadalarm Aux. only.. XIPDM-RR Rack-mount Chassis available in modules only.. For Lamp Cabinet selection refer to Ronan Lamp Cabinet Literature.. For every Auxiliary Module an associated Alarm Module is required.. For Communication Cables refer to table below. Alarm Modules XPDM - ( ) - ( ) - ( ) - ( ) A. Type: (Other sequences available) M = ISA M- F = ISA FA- ASL = ISA A-,, B. Field Contact Voltage: 0 = Vdc, Not Opto-isolated = Vdc, Not Opto-isolated = Vdc, Not Opto-isolated = Vac or Vdc, Opto-isolated = 0 Vac or 0 Vdc, Opto-isolated = 0 Vdc, Not Opto-isolated = Vac or Vdc, Opto-isolated = Vdc, Open Collector = Vac or Vdc, Opto-isolated C. Special Options and CTA** : 00 = Operational Test, NNE CTA follows FC 0 = Operational Test, NNE CTA follows Alarm 0 = Lamp Test, CTA, Lamp Inhibit Input on F, Dual Horn Selectable 0 = Lamp Test, NNE CTA follows FC = Lamp Test, NNE CTA follows FC, Lamp Inhibit on F, Dual Horn Selectable = Operational Test, NNE CTA follows FC, Lamp Inhibit Input on F, Dual Horn Selectable = Option 0 and Four Point Lamp Holder on Non-000 System = Lamp and Operational Test PB, NNE CTA follows FC, First Out Reset and Reset PB A B C D = Operational Test, NNE CTA follows FC, Dual Horn Selectable = Operational Test, NNE CTA follows FC = Operational Test, NNE CTA follows FC, FC Time Delay 0 = Lamp Test, NNE CTA follows FC, FC Time Delay = Operational Test, NNE CTA follows FC, FC Time Delay, Lamp Inhibit Input on F, Dual Horn Selectable = Lamp Test, NNE CTA follows FC, FC Time Delay, Lamp Inhibit on F, Dual Horn Selectable = Operational Test, NNE CTA follows FC, Lamp Mimic Output on TOA-TOD D. Auxiliary Relay Behavior: = NE Aux follows FC = NNE Aux follows FC = NE Aux follows Alarm = NNE Aux follows Alarm = NE Aux follows Acknowledge = NNE Aux follows Acknowledge = NE Dual Aux follows FC = NNE Dual Aux follows FC Auxiliary Contact Modules Notes: Modules contain relays only. Universal Chassis allow addition of Auxiliary Contact Modules in the field. Surface-mount Chassis provide Vdc. XCA - ( ) - AUX - ( ) = Monalarm = Dualarm = Trialarm = Quadalarm Relay Type: GP = General Purpose Relay, Vdc, 0.0 Vac HS = Hermetically Sealed Relay, Vdc, 0.0 Vac

15 INTERFACE MODULES / COMMUNICATION Interface Modules XCA-IM - ( ) - ( ) - ( ) B A. Voltage C 0 = Vdc B. Communication Protocol =Serial MODBUS RTU Slave =Serial Allen Bradley (DFI Protocol) = Serial Ronan Proprietary (X0) =Network TCP/IP (Requires XCA-NM, XCA-SC- and XCA-SC-) =Network TCP/IP (OLE for Control OPC) (Requires XCA-NM, XCA-SC- and XCA-SC-) = Consult Factory for Special Protocols A C. Physical Communication Layer to Host =RS =RS = Network 0. (RJ) XCA-NM: RS to TCP/IP Network Converter Module COMMUNICATION CABLES XPDM-LC - - ( ) - ( ) XPDM Logic to Lamp Cabinet, Conductor, with Elco Connectors at Each End, 0.00 Feet (.0 Meters) XPDM-LC - - ( ) - ( ) XPDM Logic to Lamp Cabinet with Elco Connector on X Side, Stripped Ends on Lamp Cabinet, 0.00 Feet (.0 Meters) XPDM-LC - - ( ) - ( ) XPDM Logic to Field Termination with Elco Connectors at Each End, 0.00 Feet (.0 Meters) XPDM-LC - - ( ) - ( ) XPDM Logic to Field Termination with Elco Connector at Logic, Stripped Conductor at Terminals, 0.00 Feet (.0 Meters) XPDM-LC - - ( ) - ( ) XPDM Programmable Digital Monitor to XCA-IM XPDM-LC - - ( ) - ( ) XCA-IM to Host RS,.00 Feet (. Meters) XPDM-LC - - ( ) - ( ) XCA-IM to Host RS,.00 Feet (. Meters) XPDM-LC - - ( ) - ( ) XCA-IM to XCA-NM,.00 Feet (. Meters) XPDM-LC - - ( ) - ( ) XCA-NM to Host (Category ),.00 Feet (. Meters) XPDM-LC ( ) - ( ) XlPDM Programmable Digital Monitor to XPDM,.00 Feet (. Meters) XPDM-LC - - ( ) - ( ) Cable Assembly, XCA-IM to Computer/Laptop,.00 Feet (. Meters) Standard Length (For Programming and Configuration) Length (Feet) Cable Type: 0 = PVC = XPLE

16 W A R R A N T Y Ronan warrants equipment of its own manufacture to be free from defects in material and workmanship, under normal conditions of use and service, and will repair or replace any component found to be defective, on its return, transportation charges prepaid, within one () year of its original purchase. This warranty carries no liability, either expressed or implied, beyond our obligations to replace the unit which carries the warranty. RONAN ENGINEERING COMPANY D isplay Products Division 00 Oxnard Street, Woodland Hills, CA U.S.A Fax -- Tilley Road, Crowther Industrial Estate, Washington, Tyne & Wear, U.K., NE OAE -- Fax -- Bermondsey Road, Toronto, Ontario, Canada MB Z --00 Fax sales@ r onan.com XPDM Rev. 0 0/0 Printed in U.S.A.

X11CA COMPUTER ANNUNCIATORS

X11CA COMPUTER ANNUNCIATORS S E R I E S XCA COMPUTER ANNUIATORS E N G I N E E R I N G C O M P A N Y The Ronan Series XCA Computer Annunciators are the latest generation of Ronan s state-of-the-art annunciators offered in window models.

More information

Plant Security & Fire Alarm Systems. HVAC Systems. Power Plants & Switchyards. Geographical Maps. Industrial Process Plants

Plant Security & Fire Alarm Systems. HVAC Systems. Power Plants & Switchyards. Geographical Maps. Industrial Process Plants Plant Security & Fire Alarm Systems HVAC Systems Power Plants & Switchyards 2 The Ronan Series X71 Mosaic Graphic System is ideally suited for the graphic display of industrial processes, power distribution

More information

AIS750 Series Alarm Annunciator User Manual (Ver. 2.3 / JUNE. 2014)

AIS750 Series Alarm Annunciator User Manual (Ver. 2.3 / JUNE. 2014) AIS750 Series Alarm Annunciator User Manual (Ver 23 / JUNE 2014) 3-350 John Street, Thornhill, tario L3T 5W6 Phone: 289 597 APEX (2739) Fax: 289 597 2200 Toll Free: 1 866 776 2943 Email: mail@annunciatorca

More information

AIS750 Series Alarm Annunciator

AIS750 Series Alarm Annunciator Unparallel, modular, multipoint design with Integrated controllers Two Operation Modes (Stand-alone & Serial) All sizes confi gurable up to 440 Alarm Points RS485 / RS232 Serial Communication Manual &

More information

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge Replaceable LED modules 11 Alarm Sequences as per ISA-18.1 standard Each channel/window fully field programmable RS232 or RS485 MODBUS-RTU communication Repeat relay for each window and multifunction relays

More information

4 & 8-POINT ANNUNCIATORS Instruction Manual

4 & 8-POINT ANNUNCIATORS Instruction Manual 4 & 8-POINT ANNUNCIATORS Instruction Manual 8 Field Selectable Sequences All Common ISA Sequences 4 or 8-Point (Channel) Monitoring Free Replaceable Message Labels Type 4X, NEMA 4X, IP65 Front Universal

More information

System 9000TS Sequence of Events Recorder

System 9000TS Sequence of Events Recorder System 000TS Sequence of Events Recorder ms Event Recorder and combined Annunciator Modular, rack mounting design expandable to over 000 inputs ms time stamping of events across the whole system Up to,000

More information

21-light Remote Annunciator. Owner s Manual

21-light Remote Annunciator. Owner s Manual 21-light Remote Annunciator Owner s Manual Annunciator Description... Inside Font Cover Detailed Specifications... 1 Environmental Specifications... 1 Power Supply Requirements... 1 Communication With

More information

STATUS ALARM HISTORY ALARM RESET

STATUS ALARM HISTORY ALARM RESET Instruction Manual Model 1582-42L Data Switch February 1999, Rev 0 CH1 AUTO CH2 SWITCH 1 2 1 2 STATUS 1 2 MODEL 1582 SWITCH CROSS TECHNOLOGIES INC. CH1 ONLINE MANUAL SELECT CH2 ONLINE SWITCH RESET MAN

More information

DRAFT 20 October 2014

DRAFT 20 October 2014 Technical data MTL process alarm equipment EPS rev 8 Programmable alarm annunciator Modular construction from 1 to 256 alarm channels Multi-redundant design so there is no single point of failure Choice

More information

AUTO SWITCH ALARM PS1 PS2 CH2 MANUAL REMOTE HISTORY ALARM ONLINE AUTO MANUAL SELECT SWITCH RESET

AUTO SWITCH ALARM PS1 PS2 CH2 MANUAL REMOTE HISTORY ALARM ONLINE AUTO MANUAL SELECT SWITCH RESET Instruction Manual Model 1582-125L 1:1 Switch February 2017, Rev. 0 CH1 HISTORY LINE HISTORY RESET AUTO MANUAL SELECT CH2 HISTORY LINE RESET MANUAL REMOTE AUTO PS1 PS2 MODEL 1582 CROSS TECHNOLOGIES INC.

More information

AN-3100D Annunciator

AN-3100D Annunciator AN-3100D Annunciator FOR POWER GENERATION, TRANSMISSION & DISTRIBUTION, PETROLEUM, PETROCHEMICAL, AND OTHER PROCESS INDUSTRIES INNOVATIVE ANNUNCIATOR Continuing with the widely successful AN-3100 series

More information

PD154 & PD158 VIGILANTE II ANNUNCIATORS Instruction Manual

PD154 & PD158 VIGILANTE II ANNUNCIATORS Instruction Manual PD154 & PD158 VIGILANTE II ANNUNCIATORS 8 Field Selectable Sequences All Common ISA Sequences 4 or 8-Point (Channel) Monitoring Free Replaceable Message Labels Type 4X, NEMA 4X, IP65 Front Universal Power

More information

IF-L/RF Protection Switch

IF-L/RF Protection Switch Instruction Manual Model 1582-1152 IF-L/RF Protection Switch August 2014, Rev. 0 CH1 HISTORY ALARM LINE HISTORY RESET AUTO MANUAL SELECT CH2 HISTORY ALARM LINE RESET MANUAL REMOTE AUTO ALARM PS1 PS2 MODEL

More information

Model A1700 Series Annunciator

Model A1700 Series Annunciator Seekirk Model A1700 Series Annunciator Applications: For usage in all types of process industries, electric generation, transmission and distribution, gas and water utilities. Features: The Seekirk model

More information

Series 725 Programmable Alarm Annunciator

Series 725 Programmable Alarm Annunciator Series 725 Programmable Alarm Annunciar Multi-redundant design for greater reliability Modular construction from 1 256 alarm channels Multi-redundant design so there is no single point of failure Choice

More information

ESP TECHNOLOGIES LIMITED

ESP TECHNOLOGIES LIMITED Alarm Technology ESPAN-01 Series Annunciator System Combination type User Manual (Rev. 1) ESP TECHNOLOGIES LIMITED www.esptechno.com Content Page Introduction 2 General Description 2 Overview - Annunciator

More information

RTK 9000TS system. MTL sequence of events recorder. Technical data MTL process alarm equipment

RTK 9000TS system. MTL sequence of events recorder. Technical data MTL process alarm equipment Technical data MTL process alarm equipment EPS RTK 9000TS Rev RTK 9000TS system MTL sequence of events recorder Modular, rack mounting design expandable to over 900 inputs ms time stamping of events irrespective

More information

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW 12/23/16 Rev 9 UltraLITE Model ELU General Specification 4.2 KW to 5 KW UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW 1.0 General General Specification This specification describes

More information

elite Model ELN Centralized Emergency Lighting Inverter Systems 550 W to 1.5 KW Systems

elite Model ELN Centralized Emergency Lighting Inverter Systems 550 W to 1.5 KW Systems 5/25/16 rev 6 elite Model ELN General Specification 550 W to 1.5 KW elite Model ELN Centralized Emergency Lighting Inverter Systems 550 W to 1.5 KW Systems 1.0 General General Specification This specification

More information

Instruction manual MTL process alarm equipment. October 2016 CSM 725B rev 2 MTL RTK 725B. Configuration Software Manual

Instruction manual MTL process alarm equipment. October 2016 CSM 725B rev 2 MTL RTK 725B. Configuration Software Manual Instruction manual MTL process alarm equipment October 2016 CSM 725B rev 2 MTL RTK 725B Configuration Software Manual SECTION 1 - INTRODUCTION... 5 Basic Requirements... 5 SECTION 2 - SOFTWARE INSTALLATION...

More information

Safety Instructions MS 10B ALARM UNIT MS 10B ALARM UNIT. Used symbols. Always observe this information to prevent damage to the device

Safety Instructions MS 10B ALARM UNIT MS 10B ALARM UNIT. Used symbols. Always observe this information to prevent damage to the device Safety Instructions Used symbols Important Comments Before starting with installation of the MS 10B Alarm Unit, we recommend you to read the important information beneath. Qualification The installation

More information

Complex alarming made simple

Complex alarming made simple SEL-2523 Annunciator Panel Complex alarming made simple Superbright LEDs provide easily visible alarm indication in any lighting condition. Sequential Events Recorder (SER) data help identify the root

More information

AO Annunciator Module

AO Annunciator Module General Specifications GS48C43Z01-00E-N AO-543-01 Annunciator Module GENERAL Figure 1 This module has two independent annunciator circuits. The circuits handle fault signals and operator actions (acknowledge,

More information

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16 TraceTek TTSIM-1A TraceTek Sensor Interface Module with Relay Installation/OPERATION Instructions Approvals and Certifications TYPE NM General Signaling Equipment 76LJ Only AC versions are UL listed and

More information

Model A2100 Series Annunciator

Model A2100 Series Annunciator Seekirk Model A2100 Series Annunciator Applications: For usage within transformers, switchgear, breakers and/or within any processing equipment or control room applications either attended or unattended

More information

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features. CONsOlIDATOR 4 & 8 MulTI- C h ANNEl CONTROllERs ConsoliDator 4 Model PD940 ConsoliDator 4 Features Four 4-20 Four 4-20 Outputs ConsoliDator 8 Features Eight 4-20 Two 4-20 Outputs Common Features Four Pulse

More information

IntesisBox BACnet/IP Server - Notifier ID3000 series

IntesisBox BACnet/IP Server - Notifier ID3000 series IntesisBox Server - Notifier ID3000 series Gateway for integration of Notifier ID3000, ID3002, ID50 and ID60 fire panels into enabled control systems. Integrate your Notifier fire panels into your BACnet

More information

System 9000TS Event Recorder

System 9000TS Event Recorder Important notes The 9000TS System described herein operates on a logic voltage of VDC and as standard +VDC is used for the field contact supply voltage. External power supplies using higher voltage ac/dc

More information

Across-the-Line SERIES MP300 Combined Manual and Automatic

Across-the-Line SERIES MP300 Combined Manual and Automatic Across-the-Line SERIES MP300 Combined Manual and Automatic Metron Fire Pump Controllers conform to the latest requirements of National Fire Protection Association s Standard for Centrifugal Fire Pumps

More information

ME 3011C / Alarm Indication / Quick Reference Guide

ME 3011C / Alarm Indication / Quick Reference Guide Tables of Contents Page Application 1 Features 1 Important Safety Information! 2 Note to this Guide 2 Further Information 2 Device Variants 2 General Functions 3 Annunciator Sequences - ISA 18.1 3 Plan

More information

Annuciator Logic Controllers

Annuciator Logic Controllers C B0 C C5 C C6 C C7 A B A B A B A B A5 B5 A6 B6 A7 B7 A8 B8 A9 B9 5 Annuciator Logic Controllers 68 c5 c6 c7 B B B B B5 B6 B7 B8 B9 B0 B B B B B5 B6 C0 BUZZER RETURN BZ M / BZ CTROL SIGNAL LAMP DC() DC()

More information

Soft Start Series MP700 Solid State, Reduced Voltage

Soft Start Series MP700 Solid State, Reduced Voltage Metron Fire Pump Controls and Accessories Soft Start Series MP700 Solid State, Reduced Voltage Metron Fire Pump Controllers conform to the latest requirements of National Fire Protection Association s

More information

Conventional Releasing Control Panel

Conventional Releasing Control Panel s Data Sheet Fire Safety Products Conventional Releasing Control Panel Pre-Action Deluge Agent-Releasing Fire System Model TXR-320 Remote configurable Up to two (2) hazard areas Operable with the following:

More information

TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS

TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS GENERAL INFORMATION Please read these instructions and keep them in a safe place. These instructions must

More information

STATUS ALARM ALARM HISTORY POWER HISTORY RESET

STATUS ALARM ALARM HISTORY POWER HISTORY RESET Instruction Manual Model 1582-70L2 RF Switch June 2011, Rev. D CH1 AUTO CH2 SWITCH 1 2 1 2 STATUS 1 2 MODEL 1582 SWITCH CROSS TECHNOLOGIES INC. CH1 ONLINE MANUAL SELECT CH2 SWITCH MANUAL REMOTE ONLINE

More information

725B Configuration Software Manual

725B Configuration Software Manual 725B Configuration Software Manual REV DATED DESCRIPTION AUTHOR APPROVED 0 09-03-10 First Issue P.Cartmell Page 1 of 80 SECTION 1 - SOFTWARE INSTALLATION... 5 725B ConfigurationSoftware Installation...

More information

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906 s Data Sheet Fire Safety & Security Products SXL-EX Fire Alarm Control Panel Conventional Zone Fire Alarm Control Panel ARCHITECT AND ENGINEER SPECIFICATIONS Four (4) zones expandable to eight (8) zones

More information

Instruction Manual Model L2 RF Switch

Instruction Manual Model L2 RF Switch Instruction Manual Model 1582-22L2 RF Switch November 2015, Rev. A CH1 AUTO CH2 SWITCH 1 2 1 2 STATUS 1 2 MODEL 1582 SWITCH CROSS TECHNOLOGIES INC. CH1 ONLINE MANUAL SELECT CH2 SWITCH MANUAL REMOTE ONLINE

More information

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description INTELLIGENT FIRE ALARM CONTROL UNITS MMX-2003-12NDS Intelligent Network Fire Alarm Control Unit Description Secutron s MMX-2003-12NDS Network Fire Alarm Control Unit offers modular components to meet a

More information

Instruction Manual Model Backup Switch, 1 for 8

Instruction Manual Model Backup Switch, 1 for 8 Instruction Manual Model 2582-282 Backup Switch, 1 for 8 December 2011, Rev. 0 MODEL 2582 SWITCH CROSS TECHNOLOGIES INC. SWITCH ALARM PSA PSB ALARM OFFLINE ONLINE UNIT STATUS 1 2 3 4 5 6 7 8 BU PROT MODE

More information

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM 2 Line, 16 Characters/row LCD Display Temperature Input Range -50 C to +500 C -58 F to + 932 F Enclosure NEMA Type 4X Current Rating 30A max (resistive load only) Ambient Temperature -40 C to + 40 C -40

More information

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description INTELLIGENT FIRE ALARM CONTROL UNITS MMX-2003-12NDS Intelligent Network Fire Alarm Control Unit Description Secutron's MMX-2003-12NDS is a powerful intelligent networkable fire alarm solution designed

More information

TTSIM-1A. TraceTek Sensor Interface Module with Relay. Installation/Operation Instructions. Installation Items (not supplied) Tools Required.

TTSIM-1A. TraceTek Sensor Interface Module with Relay. Installation/Operation Instructions. Installation Items (not supplied) Tools Required. TTSIM-1A TraceTek Sensor Interface Module with Relay Installation Items (not supplied) General Information Installation/Operation Instructions Please read these instructions and keep them in a safe place.

More information

SUB-STATION ANNUNCIATOR INSTRUCTION MANUAL

SUB-STATION ANNUNCIATOR INSTRUCTION MANUAL SUB-STATION ANNUNCIATOR INSTRUCTION MANUAL Page 1 of 76 The following methods are used in this manual to alert the user to important information:- WARNING! Warnings are provided for operator safety and

More information

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM Local configuration and monitoring with Raychem Touch 1500 touch screen display PRODUCT OVERVIEW The Raychem NGC-40 is a multipoint electronic

More information

ACCURATE ELECTRONICS INC PO BOX SW HALL BLVD BEAVERTON OR USA FAX

ACCURATE ELECTRONICS INC PO BOX SW HALL BLVD BEAVERTON OR USA FAX Page 1 of 10 Model 10807800 January 2014 ACCURATE ELECTRONICS INC PO BOX 1654 97075-1654 8687 SW HALL BLVD 97008 BEAVERTON OR USA 503.641.0118 FAX 503.646.3903 WWW.ACCURATE.ORG Practice Section 10807800

More information

Model A1600 Series Annunciator

Model A1600 Series Annunciator Seekirk Model A1600 Series Annunciator Applications: For usage in all types of process industries, electric generation, transmission and distribution, gas and water utilities. Features: The Seekirk model

More information

RS485 MODBUS Module 8AI

RS485 MODBUS Module 8AI Version 1.4 15/04/2013 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained in this manual have

More information

For Complete Fire and Gas Solutions

For Complete Fire and Gas Solutions Industrial Fire For Complete Fire and Gas Solutions 2 The Total Package What do you need from an integrated fire and gas system? In industrial fire and gas environments it s important to have a reliable

More information

P2267 NETWORK INTERFACE

P2267 NETWORK INTERFACE P2267 NETWORK INTERFACE USER MANUAL FOR OPERATING SYSTEMS: 22031-03 23636-01 October 2009 Associated Controls (Australia) Pty. Limited 2-4 Norfolk Road Greenacre, NSW, 2190. PH +61 2 9642 4922, FAX +61

More information

16.34 Multiplex Fire Alarm System Construction Standards Page 1 of 5

16.34 Multiplex Fire Alarm System Construction Standards Page 1 of 5 Construction Standards Page 1 of 5.1 General Description.1 The University requires that all new fire alarm system control panel, components, and devices, as required for the project, be Secutron 2900 Series

More information

Nov 08 PRODUCT SPECIFICATION SHEET

Nov 08 PRODUCT SPECIFICATION SHEET Honeywell UDC1200 and UDC1700 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS 51-52-03-35 Nov 08 PRODUCT SPECIFICATION SHEET OVERVIEW The UDC1200 & UDC1700 are microprocessor-based 1/16 DIN and 1/8 DIN

More information

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM Local configuration and monitoring with Raychem Touch 1500 touch screen display PRODUCT OVERVIEW The nvent RAYCHEM NGC-40 is a multipoint

More information

LED Driver Module. These instructions contain procedures to follow in order to avoid personal injury and damage to equipment.

LED Driver Module. These instructions contain procedures to follow in order to avoid personal injury and damage to equipment. LED Driver Module Installation Guide 1.0 Notice These instructions are for installing Radionics LED Driver Module in a fire alarm system controlled by Radionics D8024 or D10024 Fire Alarm Control Panels

More information

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE General Description This guide provides a summary for installing and configuring the Centaur TM Cube Slave Alarm Signalling Equipment

More information

INTELLIGENT FIRE ALARM CONTROL PANEL

INTELLIGENT FIRE ALARM CONTROL PANEL INTELLIGENT FIRE ALARM CONTROL PANEL FX-2000 SERIES Description Mircom s FX-2000 Series Intelligent Analog Fire Alarm Control Panel is designed to provide maximum flexibility of analog system requirements

More information

ACTIVE INFRARED BARRIER

ACTIVE INFRARED BARRIER Although PROTECH provides high security indoor intrusion sensors for the military and government markets, our specialty is outdoor protection. Since we first introduced our PIRAMID outdoor dual technology

More information

STATUS ALARM ALARM HISTORY POWER HISTORY RESET

STATUS ALARM ALARM HISTORY POWER HISTORY RESET Instruction Manual Model 1582-152 RF Protection Switch November 2009, Rev B. CH1 AUTO CH2 SWITCH 1 2 1 2 STATUS 1 2 MODEL 1582 SWITCH CROSS TECHNOLOGIES INC. CH1 ONLINE MANUAL SELECT CH2 SWITCH MANUAL

More information

System 9000TS Sequence of Events Recorder

System 9000TS Sequence of Events Recorder System 9000TS Sequence of Events Recorder ms Event Recorder and combined Annunciator The RTK System 9000TS Sequence of Events Recorder leads the way in the latest technically advanced event and alarm management

More information

SM3000 Videographic Recorder. User Guide. Modbus (RTU) Communications Option

SM3000 Videographic Recorder. User Guide. Modbus (RTU) Communications Option SM3000 Videographic Recorder User Guide (RTU) Communications Option ABB The Company We are an established world force in the design and manufacture of instrumentation for industrial process control, flow

More information

MODEL B2 INSTALLATION MANUAL

MODEL B2 INSTALLATION MANUAL RELEASE DEVICES GENERAL DESCRIPTION MODEL B2 INSTALLATION MANUAL S/N: The B2 Series Time Delay Release Devices are UL Listed, Canadian Listed, and CSFM Listed for use on rolling doors, single-slide and

More information

RAYCHEM NGC-30 COMPONENTS

RAYCHEM NGC-30 COMPONENTS PANEL MOUNTED ELECTRONIC MULTI-CIRCUIT HEAT-TRACING CONTROL, MONITORING AND POWER DISTRIBUTION SYSTEM PRODUCT OVERVIEW CABLE DUCT Card Rack Modules TERMINAL STRIP PLINTH MAIN SWITCH 800 mm USER INTERFACE

More information

Industrial Grade Gas Detection Detecting The Difference

Industrial Grade Gas Detection Detecting The Difference detcon inc. Industrial Grade Gas Detection Detecting The Difference PO Box 8067 The Woodlands, TX 77387 888-367-4286 (toll free) 713-559-9200 281-292-2860 (fax) sales@detcon.com Catalog #CB-0409 www.detcon.com

More information

Process & TeMPerATUre UniversAl input DigiTAl MeTers

Process & TeMPerATUre UniversAl input DigiTAl MeTers Process & TeMPerATUre UniversAl input DigiTAl MeTers nova PD56 series Thermocouple, rtd, & Process inputs Universal Power supply 1-24 va c Up to 3 Alarm relays retransmitting 4-2 ma output input Max/Min

More information

Type 8001 PRIME MOVER CONTROLS INC. ALARM ANNUNCIATOR TYPE8001 FEATURES SB 8001B

Type 8001 PRIME MOVER CONTROLS INC. ALARM ANNUNCIATOR TYPE8001 FEATURES SB 8001B PRODUCT BULLETIN SB 8001B Type 8001 ALARM ANNUNCIATOR TYPE8001 FEATURES 16 or 32 alarm points per flush mount enclosure Displays are backlit with long life LEDs and engraved to suit Dimmer controls built

More information

UDC1000 and UDC1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

UDC1000 and UDC1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS UDC1000 and UDC1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS EN0I-6041 4/01 PRODUCT SPECIFICATION SHEET OVERVIEW The UDC1000 and UDC1500 are microprocessor-based 1/16 DIN and 1/8 DIN controllers

More information

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL PRODUCT Specification FEATURES Designed To Meet The Requirements Of EN54 Expandable From 1 To 5 Loops As Standard A Variety Of Networking Options

More information

Flair 500 Series Annunciators

Flair 500 Series Annunciators Flair 500 Series s Basics Flair Multi-Zone s (MZAs) are fully functional, flexible, programmable micro controller based alarm control panels. They can be used independently d or in conjunction with other

More information

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS NOVA PD56 Series Thermocouple, RTD, & Process Inputs Universal Power Supply 1-24 VAC Up to 3 Alarm Relays Retransmitting 4-2 ma Output Input Max/Min

More information

VA301C CONTROLLER WITH BACnet OPTION

VA301C CONTROLLER WITH BACnet OPTION ORDERING INFORMATION VA301C Controller VA301C-DLC VA301C-DLC-BIP Gas detection controller with data logging, display and plastic housing. Gas detection controller with data logging and display, BACnet/IP

More information

UNC100 Integra Manual

UNC100 Integra Manual UNC100 Integra Manual New Generation Building Security July 30, 2014 V1.2 Copyright Notice Copyright 1995-2014 by All rights reserved Worldwide. Printed in Canada. This publication has been provided pursuant

More information

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products: Model 2102 Gas Alarm Panel APPLICABILITY & EFFECTIVITY This manual provides instructions for the following Sierra Monitor products: Model Description 2102-00 Alarm Panel 2 Channel 2102-01 Alarm Panel 2

More information

NETWORK FIRE ALARM CONTROL PANEL. Features

NETWORK FIRE ALARM CONTROL PANEL. Features NETWORK FIRE ALARM CONTROL PANEL FX-2009-12N Description FX-2009-12N in a BB-5008 enclosure. Mircom s FleX-Net TM FX-2009-12N Network Fire Alarm Control Panel offers modular components to meet a wide variety

More information

DWYER INSTRUMENTS, INC. P.O. BOX 373 MICHIGAN CITY, INDIANA 46360, U.S.A. Series 670 Hood Monitor. Bulletin AV-670

DWYER INSTRUMENTS, INC. P.O. BOX 373 MICHIGAN CITY, INDIANA 46360, U.S.A. Series 670 Hood Monitor. Bulletin AV-670 Bulletin AV-670 Series 670 Hood Monitor Specifications - Installation and Operating Instructions DWYER INSTRUMENTS, INC. P.O. BOX 373 MICHIGAN CITY, INDIANA 46360, U.S.A. Phone: 219/879-8000 Fax: 219/872-9057

More information

ACCURATE ELECTRONICS INC

ACCURATE ELECTRONICS INC ACCURATE ELECTRONICS INC Page 1 of 7 Model 108078 2 Sept 09 WWW.ACCURATE.ORG PO BOX 1654 97075-1654 8687 SW Hall Blvd 97008 BEAVERTON OR USA 503.641.0118 FAX 503.646.3903 Practice Section 108078 Rev A

More information

Fire and Gas Monitoring Panel ST7-HV

Fire and Gas Monitoring Panel ST7-HV Fire and Gas Monitoring Panel ST7-HV INTRODUCTION TO THE ST7-HV SYSTEM The ST7-HV system is a programmable PLC suitable for safety and security installations with a high technological and economic content

More information

LORAIN CIP 4890/48120 DC Power System

LORAIN CIP 4890/48120 DC Power System DC Power for Business-Critical Continuity Key Features Compact flexibility provides rectifiers, distribution, and controller in one shelf Constant power delivers more current at lower voltages to meet

More information

Sensor Interface Module Installation/Operation Instructions

Sensor Interface Module Installation/Operation Instructions TraceTek TTSIM-1 Sensor Interface Module Installation/Operation Instructions Approvals and Certifications TYPE NM General Signaling Equipment 76LJ Only AC versions are UL listed and VDE Certified. For

More information

Suggested Specification: Benchmark 1.5 Low NOx Gas-Fired Hydronic Boiler(s)

Suggested Specification: Benchmark 1.5 Low NOx Gas-Fired Hydronic Boiler(s) Furnish and install as shown on AERCO International plans and operation and maintenance manuals, with all applicable codes and authorities having local, state and federal jurisdiction, Benchmark Series

More information

Variable Frequency Drive SERIES MP800 VFD

Variable Frequency Drive SERIES MP800 VFD Metron Fire Pump Controls and Accessories Variable Frequency Drive SERIES MP800 VFD Metron Fire Pump Controllers conform to the latest requirements of National Fire Protection Association s Standard for

More information

Modbus TCP/IP Option Instruction Manual

Modbus TCP/IP Option Instruction Manual W A L C H E M An Iwaki America Company WebMaster Modbus TCP/IP Option Web Master WIND Modbus TCP/IP Option Instruction Manual s825v008 and higher Five Boynton Road Hopping Brook Park Holliston, MA 01746

More information

MODUL-R FIRE ALARM CONTROL PANELS. MR-2900/MR-2920 Addressable Fire Alarm Control Panels MEA. Features. Description

MODUL-R FIRE ALARM CONTROL PANELS. MR-2900/MR-2920 Addressable Fire Alarm Control Panels MEA. Features. Description MODUL-R FIRE ALARM CONTROL PANELS MR-2900/MR-2920 Addressable Fire Alarm Control Panels Description MR-2900 Fire Alarm Control Panel The MR-2900 fire alarm system control unit is the heart of a sophisticated

More information

INTREPID Perimeter Intrusion Detection System

INTREPID Perimeter Intrusion Detection System TM INTREPID Perimeter Intrusion Detection System Next Generation Perimeter Protection icropoint Cable combines patented Southwest Microwave technology with microprocessor power and laptop computer convenience.

More information

I/A Series 716C 1/16 DIN Temperature Controller

I/A Series 716C 1/16 DIN Temperature Controller Product Specifications I/A Series 716C 1/16 DIN Temperature Controller PSS 2C-1B5 A The Foxboro 716C is a powerful compact, 1/16 DIN, microprocessor-based temperature controller that offers a variety of

More information

RELEASE DEVICE CONTROLS

RELEASE DEVICE CONTROLS RELEASE DEVICE CONTROLS RELEASE DEVICE MODEL C+ INSTALLATION MANUAL UL LISTED CANADIAN LISTED CSFM: 7300-48:00 GENERAL DESCRIPTION: MADE IN THE U.S.A. S/N: The LM0-C+ Release Device/Control Panel is a

More information

INTELLIGENT FIRE ALARM AND AUDIO NETWORK SYSTEM. Features

INTELLIGENT FIRE ALARM AND AUDIO NETWORK SYSTEM. Features INTELLIGENT FIRE ALARM AND AUDIO NETWORK SYSTEM Description Mircom s FleX-Net TM Series Network Fire Alarm Control Panels offer modular components to meet a wide variety of applications. Designed for peerto-peer

More information

ANNUNCIATOR INSTRUMENTS Model PD141AFO Instruction Manual

ANNUNCIATOR INSTRUMENTS Model PD141AFO Instruction Manual ANNUNCIATOR INSTRUMENTS Model PD141AFO Instruction Manual From urgent alarms to routine messages, the PD141AFO VIGILANTE handles all types of operational messages with simplicity and economy. The VIGILANTE

More information

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6 Digital Gas Transmitters with Auxiliary s & Control Specifications subject to change without notice. USA 181011 Page 1 of 5 DESCRIPTION Digital RS-485 communicating, addressable toxic and combustible gas

More information

4100U City and Relay Cards Installation Instructions

4100U City and Relay Cards Installation Instructions 4100U City and Relay Cards Installation Instructions Introduction This publication describes the installation procedure for the following: 4100-6031/6032 City Circuit Cards 4100-6033 Alarm Relay Card Inspecting

More information

Panel Mounted Fault Annunciator Series

Panel Mounted Fault Annunciator Series Panel Mounted Fault Annunciator Series BSM / USM Panel-mounted fault annunciator Annunciators for panel mounting with,,,, 0 and signal inputs Storage of the last state of inputs and sequence in the case

More information

ESSEX ENGINEERING CORPORATION

ESSEX ENGINEERING CORPORATION WATER/WASTEWATER TREATMENT CONTROL SYSTEMS AND SUBSYSTEMS 2000 SERIES CONTROL SYSTEMS: 2000 series are for surface mounting inside a control cabinet Model 2024 Electronic Alternator Duplex (two pump) pump

More information

PWGSC Ontario MULTIPLEX FIRE ALARM SYSTEM Sect Region Project Page 1 Number R

PWGSC Ontario MULTIPLEX FIRE ALARM SYSTEM Sect Region Project Page 1 Number R Region Project Page 1 PART 1 - GENERAL 1.1 REFERENCES.1 CAN/ULC-S524-2006, Standard for the Installation of Fire Alarm Systems..2 CAN/ULC-S525-2007, Audible Signal Device for Fire Alarm Systems..3 CAN/ULC-S526-2007,

More information

Standard Devices. Electronic Alarm Indication Systems. ME 3011b

Standard Devices. Electronic Alarm Indication Systems. ME 3011b Standard Devices Electronic Alarm Indication Systems ME 3011b Before connecting and powering this device, please read carefully the manual, and refer to it whenever you have any doubts. This brochure is

More information

Specification/ Data Sheet

Specification/ Data Sheet Specification/ Data Sheet TRITON RP Agent Release Control Panel FEATURES Agent Release Control Panel designed specifically for suppression release operation with: Four initiating device circuits (IDCs)

More information

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION IBAS LIGHTING CONTROL

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION IBAS LIGHTING CONTROL PART 0 A/E INSTRUCTIONS 0.01 DESIGN REQUIREMENTS A. Minimum lighting control (base scope of work) shall include all corridors. The lighting in all the corridors shall be turned on (if not already on) if

More information

LORAIN CSP DC Power System

LORAIN CSP DC Power System DC Power for Business-Critical Continuity Key Features Compact flexibility provides more space for revenue generating equipment Constant power delivers more current at lower voltages to meet load or recharge

More information

WM3000 WIRELESS MODULES

WM3000 WIRELESS MODULES WM3000 WIRELESS MODULES $$:05 $$:07 INSTALLATION INSTRUCTIONS Table of Contents Installation... 3 Mounting Instructions & Connections... 3 Setting the Dip Switches... 4 Setting the Recognition Time...

More information

RTD TEMPERATURE SENSING SYSTEM

RTD TEMPERATURE SENSING SYSTEM General Overview RTD TEMPERATURE SENSING SYSTEM The Prime Technology RTD Temperature System 9219-00-0002 is a three-channel temperature measuring system that utilizes two RTD Temperature Sensor inputs

More information

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices. FireCell Radio Hub Fully addressable Wireless activation Third party approved (EN54) 2-way radio communication Loop powered Diagnostics port Range in excess of 150 metres Overview The model FCX-500-001

More information