1 esting aboratory rofessional TEST REPORT nc. TEST METHOD CONDUCTED AATCC Test Method Electrostatic Propensity of carpets DESCRIPTIO NOFTESTSAMP.. IDENTIFICATION Ambition II L E ROLL.. CONSTRUCTjON Loop Pile FIBER Action Bac :rest RESULTS MAXIMUMVOL.TACE NEG 0.7 KV ENERAL PRINCIPLE This method is designed to assess the static propensity of carpet by controlled I boratory simulation of conditions which are known from experience to be strongly ontributory to excessive accumulation of static charges. A carpet preconditioned to equilibrium at controlled atmospheric conditions is alked on by a test subject in a specified manner with specified shoe soles. The static harges which build up on the tester are monitored continuously by a recorder. t A neolite shoe sale has been chosen as the primary reference material because its tatic performance is much like that of many common leathers. It is a commonly used shoe ole material and can be easily cleaned, while its chemical and physical properties are quite niform. A chrome tanned leather shoe sole has been chosen for a secondary reference aterial because it is representative of a certain class of leathers whose performance differs c ignificantly from that of neolite soles on certain carpet fiber. statistically, chrome tanned eather comprises a very small percentage of the shoe sole market, but must be considered in critical applications. This facilily! accredited by the National Voluntary [.,boratory Accreditation Program for the specific scope of accreditation under [.,b Code This accreditati does not constitute an endorsement, certification, or approval by NIST or any agency of the UnitedSta\es Government for the producttested. This report i provided for the exclusive use of the client to whomitis addressed. It may be used in its entirely te gain product acceptance from dujy constituted authorities. his report applies only to those samp!es1ested and is not necessarily indicat!ve 01 apparentlyidenlicafdr similar products. This report, or the name 0.1 Professional esting ["boratory, tnc., shall not be used under any circumstance in advertising to the general public. [ 714 Glen ood Place Dalton, GA Fax: protest@alltel.net
2 Professional. ', TEST REPORT 714 Glen ood Place Dalton, GA ' Fax: esting,. CLIENT c cc c. AATCC Test Method Electrostatic Propensity of Carpets c - ROLL Ambition II I.I CONSTRUCTION. FIBER I,', ",- "" ", "'",REFERENCE"" c, Action Bac The sample is conditioned to equilibrium and tested at 70::1: 2 F and % relative humidity. SAMPLE PREPARATION SUBSTRATE 40 Ounce Rubberized Jute/Hair Pad t O7E: The tests reported below were conducted in accordance with the AA TCC Test Method , Section Step Test procedure.. JrEST RESULTS MAXIMUM ".--""'. VOLTAGE -0.6 KV -0.8 KV AVERAGE r1he results of this test relate to the sample of carpet tested. It's static performance may be altered in service as result of wear, soiling, cleaning, temperature, relative humidity, etc PPROVED BY: ' L /?.This accreditatiofoes not constitute an endprsement, certification, or approva) by NI5T or OI)Y agency of the United States Government.tor the product tested. This report i provided for the exclusive use of the client to whom i( is addressed. It lj1aybe used in its etirety(o gain product acceptance from duly constituted authoriies. Professional estlng l1iooratory,, shall not be used under anyclrtymstance..n advertising to the general public.
3 Professional Testing CLIENT TEST REPORT TEST NUMBER DATE 05/10/04 PACE 1 Of 2 TEST METHOD CONDUCTED ASTM E specific Optical Density of Smoke Generated by solid Materials, also referenced as NFPA 2Se DESCRIPTION OF TEST SAMPLE IDENTrFICATION Ambition II ROLL CONSTRUCTION Loop Pile FIBER Action 8ac :rest RESULTS FLAMING 126 ENERAL PRINCIPLE This procedure is designed to measure the specific optical density of smoke enerated by the test specimen within a closed chamber. Each specimen is exposed to an lectrically heated radiant-energy source positioned to provide a constant irradiance level f 2.5 watts/square cm on the specimen surface. Measurements are recorded through a hotometric system employing a vertical beam of light and a photo detector positioned to etect the attenuation of light transmittance caused by smoke accumulation within the hamber. The light transmittance measurements are used to calculate specific optical ensitv, a quantitative value which can be factored to estimate the smoke potential of aterials. Two burning conditions can be simulated by the test apparatus. The radiant eating in the absence of ignition is referred to as the Non-Flaming Mode. A flaming ombustion in the presence of supporting radiation constitutes the Flaming Mode. This facilitytaccredited by the National Voluntary LAboratory Accreditation Program for the specific scope of accreditation under LAb Code This accreditation oes not constitute an endorsement, certification, or approval by NIST or any agency ofthe UnitedStatsGovernmentforthe product tested. This report is provided for the exclusi-.. use of the client to whom it is addressed. It may be used in its entirety to gain product acceptance from duly constituted authorities. his report applies only to those samples tested and is not necessarily indi<;ative of apparently identical or similar products. This report, orthe nam of Professional sting laboratory,, shall not be used under any circumstance in advertising to the general public. 714 GlenOOd Place Dalton, GA Fax: protest@alltel.net
4 I!esting DA'.c TE 05/10/04 PA u E 2 of 2 CLIENT cc -.. TESTMETHODCONDUCTED ASTM E Specific Optical Density of Smoke Generated by Solid Materials, also referenced as NFPA Ambition II ROLL.. -. CONSTUCON r7:""",," FIBER, Action Bac ';i; 24 Hours at 140 degrees F 24 Hours at 70 degrees F and 50% relative humidity 113 V JRRADI.ANCE 2.5 watts/sq cm 95 degrees F CHAMBER PRESSURE 3" H2O Flaming I J'" ;"f"',t,i!;$,,;,!'-'i,,&, PPROVED BY: 4., This facility i accredited by the National Voluntary laboratory Accreditation Program for the specific scope of accreditati,?n under lab Code This accreditation DeS not constitute an endorsement, certification, or approval by NIST or any agency of th United States Govrnment for the product tested. This report i rovided for the exclusive use of the client to whom it is addressed. It may be used in its entirety to gain product acceptance from duly constituted authorities. is repqrtappliesonlyto those samples1ested and is not necessar;!y indicative of apparently identical orimilar products. This report, or the name of Professional sting l1iboratory,.. shaffnotbe used under any circumstance in advertising to the genera! public. /7 714 Glen ood Place Dalton,GA Fax: protest@alltel.net
5 I Professional Testing TEST REPORT DESCRIPTION OF TEST SAMPLE.." IDENTIFICATION Ambition II ROLL.. CONSTRUCT1ON REFERENCE ". This test report relates to the iastallati9r ir aeee.-tlr..ee v..; Action Bac criteria variation set In forth me criteria in the report. may Any - produce djtterent resulm. ITEST RESULTS AVERAGE,- CRITICAL. RADIANT FLUX.34 watts/square Cm * GENERAL PRINCIPLE This procedure is designed to measure the critical radiant flux at flame out, of horizontally mounted floor covering systems exposed to a flaming ignition in a test chamber which provides a graded radiant heat energy environment. The imposed radiant flux simulates the thermal radiation levels likely to impinge on the floors of a building whose upper surfaces are heated by flames of compartment. The test result is an average critical radiant flux (watts/square cm) which indicates the level of radiant heat energy required to sustain flame propagation in the flooring system. Theoretically, if a room fire does not impose a radiant flux that exceeds this critical level on a corridor floor covering system, flame spread will not occur. The NFPA Life safety code 101 specifies as Class 1 critical Radiant Flux of.45 watts/sq cm or higher and Class 2 Critical Radiant Flux as watts/sq cm. This facili[ is accredited by the National Voluntary LIboratory Accreditation Program for the sific scope of accreditation under LIb Code This accreditati n does not constitute an endorsement, certification, or approvafbyn!st orany agencyoftheuniteiistatesgovemmentforthe product tested. This repo is provided for the exclusive use of the client to whom it is addressed. It may be used in its entirety to gain product acr.eptance from duly constituted authorities This report applies only to those samples tested and is not necessarily indicative of apparently identical or simila; pr..ducts. This report, or the name of Profession I Testing LIboratory,, shall not be used under any circumstance in advertising to the general public. i'14 GlelWOOd Place Dalton, GA Fax: protest@alltel.net
6 !. Professional TEST REPORT TEST NUMBER DATE Testing CLIENT Ambition II FrBER Action Bac criteria set.forth in the report. Any REFERENCE variation in idirii11l1111 producedifferent results. FLOORING SYSTEM ASSEMB LY SUBSTRATE t!:":.;:f, M}neral-Fiber/cement UNDERLAYMENTiiW);!:::; Direct Glue Down ADHESIVE :",;k Subset 1000 Board Each test sample was conditioned a minimum 70 :t 50 F and 50:t 5% relative humidity. CONDITIONING of 96 hours at "rest RESULTS rl TEST DATA. DISTANCE BURNED TIME TO FLAME OUT CRITICAL RADIANT FLUX 37 minutes r AVERACECR"TICAL STANDARD I COEFFICIENT - RADIANT FLUX DEVIATIONI OF VARIATIONI NOTE: Meets or exceeds Class 2 safety Code 101. tin.34 watts/square cm*.04 watts/square cm 12% as specifd r I in NFPA Life PPROVED BY: This facility accredited by the National Voluntary boratory Accreditation Program for the specific scope of accreditation under Lab Code This accreditation not constitute an endorsement certification, or proval by NISTor anyagencyof the United StatesGovernmentfor the producttested. This report i provided for the exclusive use of the client to whom it isaddressed. It may be used in its entirety to gain product acceptancefrom duly constituted authorities. his report applionly to those samplestested and is not necessariiyindicativeof apparentlyidentical or similarproducts. This report, or the name of Professional es1ing,. shall not beused under anycircumstancein advertisingtothe generalpublic. 714 Gle d Place Dalton, GA Fax: protest@alltel.net
SHAW CONTRACT DESCRIPTION OF TEST SAMPLE
TEST METHOD CONDUCTED AATCC Test Method 134-1996 Electrostatic propensity of carpets DESCRIPTION OF TEST SAMPLE IDENTIFICATION SAO20 GloW UPAT ROLL CONSTRUCTION 465883J Multi-Level cut & Loop Pile FIBER
More information~ 0."0... DESCRI PT ION OF TEST SAM PLE
TEST METHOD CONDUCTED AATCC Test Method 134-1996 Electrostatic propensity of carpets IDENTIF.lCATION ~ 0."0... DESCRI PT ION OF TEST SAM PLE...c" 50912 Cu Itu re ROLL.. CONSTRUCT.lON Textured Loop Pile
More informationSTilE/DIVISION OF SHAW DESCRI.P TION 0 FT E STSAMP L E
CLIENT TEST NUMBER 0081483 DATE 12/02/03 PACE 1 of 2 DESCRI.P TION 0 FT E STSAMP L E IDENTIFICATION 59358 Color Play EW 24 -,. c'..-.. B- ACKINC REFERENCE GENERAL PRINCIPLE This method is designed to assess
More informationInc. PACE 1 of 2. Testing Laboratory. AA TCC Test Method Electrostatic Propensity of Carpets TEST M ET"ODCON D UCTED
TEST REPORT PACE 1 of 2 -~.- TEST M ET"ODCON D UCTED AA TCC Test Method 134-1996 Electrostatic Propensity of Carpets I.DENTI.FIQADON 59371 peto II 26 EW 24 COLOR ROLL -" CONSTRUCTION BACKING REFERENCE
More informationSTilE/DIVISION OF SHAW
~ Professional CLIENT TEST REPORT STilE/DIVISION OF SHAW fdentiffcatfon COLOṘ SO-U3577 CONSTRUCTION Textured LOOp Pile FIBER - BACKINO ~ REFERENCE TEST NO: 111703-32 MAXIMUM VOLTAGE NEG 2.8 KV CENERAL
More informationSTilE/DIVISION OF SHAW DESCRIPTION OF TEST SAMPLE
Professional DESCRIPTION OF TEST SAMPLE - IDENTIFICATION BACKINC 59342 connect EW24 LOOP Pile GENERAL PRINCIPLE This method is designed to assess the static propensity of flooring material by controlled
More informationTEST REPORT DATE: TEST NUMBER: DESCRIPTION OF TEST SAMPLE
Professional Testing Laboratory, Inc. TEST REPORT DATE: 06-16-2014 TEST NUMBER: 0209182 CLIENT Artistry Hardwood Flooring TEST METHOD CONDUCTED IDENTIFICATION CONSTRUCTION REFERENCE ASTM E648 Standard
More informationEnviroScape Mural. pre-pasted printable wallcovering material. Choose your GREEN resource from a leading solutions provider.
by NEENAH EnviroScape Mural pre-pasted printable wallcovering material EnviroScape Mural is a PVC free wall, window or hard surface scaping product that is pre-pasted with a water activated adhesive backing
More informationTEST REPORT. NFPA 253 / ASTM E648-14c Standard Test Method for Critical Radiant Flux of Floor-Covering Systems Using a Radiant Heat Energy Source
NFPA 253 / ASTM E648-14c Standard Test Method for Critical Radiant Flux of Floor-Covering Systems Using a Radiant Heat Energy Source TEST REPORT Kolay 5mm 20mil Wear Layer LVT with Fiberglass Core Project
More informationASTM E662 TESTING FOR COLE MOTORSPORTS/CM RACING PRODUCTS ON WINDSHIELD TEAROFFS ON ¼ GLASS VTEC # TESTED: MARCH 27, 2009
ASTM E662 TESTING FOR COLE MOTORSPORTS/CM RACING PRODUCTS ON WINDSHIELD TEAROFFS ON ¼ GLASS VTEC #100-3191-1 TESTED: MARCH 27, 2009 April 2, 2009 Client: Attention: Cole Motorsports/CM Racing Products
More informationBS EN ISO : 2010
Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 (0 1925 655116 F : +44 (0) 1925 655419 E : warrington@exova.com W: www.exova.com BS EN ISO 92391: 2010 Fire Tests For Determination
More informationBS EN ISO : 2010
Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 (0 1925 655116 F : +44 (0) 1925 655419 E : warrington@exova.com W: www.exova.com BS EN ISO 92391: 2010 Fire Tests For Determination
More informationBS EN ISO : Fire Tests For Determination Of The Burning Behaviour of Floorings. WF Report Number. Date: 16 th November 2009.
Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 (0) 1925 655 116 F : +44 (0) 1925 655 419 E : warrington@exova.com W: www.exova.com BS EN ISO 92391: 2002 Fire Tests For
More informationBS EN ISO : 2010
Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 (0 1925 655116 F : +44 (0) 1925 655419 E : warrington@exova.com W: www.exova.com Fire Tests For Determination Of The Burning
More informationASTM E 662 Rate of Smoke Generation of OXIFREE TM198"
ELECTRONIC COPY ASTM E 662 Rate of Smoke Generation of OXIFREE TM198" A Report To: Oxifree Global LLC 22955 State Highway 249, Suite 6 Tomball, TX 77375 USA Phone: (281) 251-7171 E-mail: ed.hall@oxifree.com
More informationISO INTERNATIONAL STANDARD. Reaction to fire tests for floorings Part 1: Determination of the burning behaviour using a radiant heat source
INTERNATIONAL STANDARD ISO 9239-1 Third edition 2010-06-15 Reaction to fire tests for floorings Part 1: Determination of the burning behaviour using a radiant heat source Essais de réaction au feu des
More informationAnalysis Report
Prestige Carpets bvba Dhr. Dirk Santens Klein Frankrijk 38 9600 RONSE Your notice of Your reference Date 19-06-2013 24-07-2013 Required tests : Identification number T1309624 Information given by the client
More informationBCTC CARPET TECHNICAL CENTRE
Wira House West Park Ring Road Leeds, LS16 6QL Tel: +44 (0)113 259 1999 Fax: +44 (0)113 278 0306 Web: http://www.bttg.co.uk/bctc Email: CSLeeds@bttg.co.uk 7 September 2010 Page 1 of 7 Client: Rectory Farm
More informationTEST REPORT. Report No.: D Rendered to: 3M COMPANY St. Paul, Minnesota
Architectural Testing TEST REPORT Report No.: D7913.05-121-24 Rendered to: 3M COMPANY St. Paul, Minnesota PRODUCT TYPE: Window Film SERIES/MODEL: 3M Scotchshield Ultra 800 TEST METHOD: ASTM E 84-11a, Standard
More informationASTM E 662 Rate of Smoke Generation of "Moniflex as manufactured by Isoflex AB"
UNCONTROLLED ELECTRONIC COPY ASTM E 662 Rate of Smoke Generation of "Moniflex as manufactured by Isoflex AB" A Report To: Ciucevich 7200 Vermilion Ct. Wake Forest, NC 27587 USA Phone: (919) 570-291 E-mail:
More informationM E M O R A N D U M. Diane Matthews, Administrator, Technical Projects. NFPA 101 First Draft Letter Ballot (A2014)
National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169 7471 Phone: 617 770 3000 Fax: 617 770 0700 www.nfpa.org M E M O R A N D U M TO: FROM: NFPA Technical Committee on Furnishings
More informationStandard Laboratory Test Practice For Efficacy Evaluation of Interim. Carpet Maintenance Systems
P.O. Box 2048 Dalton Georgia 30722-2048 706.278.3176 carpet-rug.org CRI TM 122 Standard Laboratory Test Practice for Efficacy Evaluation of Interim Carpet Maintenance Systems Standard Laboratory Test Practice
More informationFABRITRAK SYSTEMS, INC. FIRE TEST REPORT
FABRITRAK SYSTEMS, INC. FIRE TEST REPORT SCOPE OF WORK ASTM E84 TESTING ON POLYESTER INFILL REPORT NUMBER H5200.01-121-24 TEST DATE 08/31/17 ISSUE DATE 09/20/17 RECORD RETENTION END DATE 08/31/21 PAGES
More informationTEST REPORT. Report No.: E Test Date: May 6, Rendered to: FUNDERMAX GMBH A-9300 St. Veit an der Glan, Austria
TEST REPORT Report No.: E6736.01-121-24 Test Date: May 6, 2015 Rendered to: FUNDERMAX GMBH A-9300 St. Veit an der Glan, Austria PRODUCT TYPE: Max Exterior F-Quality SERIES/MODEL: Décor. 0085 TEST METHOD:
More informationReport VNLF Test Report
Report VNLF 081158.1 Test Report Applicant KLEEN-TEX Industries in Europa GmbH Münchner Straße 21 6330-Kufstein Austria Reference Mrs. Antje Schlegel Application Determination ofthe burning behaviour according
More informationSIGMADEK, LTD. FIRE TEST REPORT
SIGMADEK, LTD. FIRE TEST REPORT SCOPE OF WORK ASTM E84 TESTING ON ALUMINUM EXTRUSION DECK BOARD C/W PORCELAIN TILE INSERT REPORT NUMBER H5331.01-121-24 TEST DATE 09/13/17 ISSUE DATE 10/03/17 RECORD RETENTION
More informationAnalysis Report
Forbo Flooring Coral nv Dhr. Jan van Galen Postbus 17 1560 AA KROMMENIE Nederland Your notice of Your reference Date 08-02-2016 23-02-2016 Analysis Report 16.00634.08 Required tests : Identification number
More informationPERFORMANCE TEST REPORT. Rendered to: VELUX America, Inc. PRODUCT: SUN TUNNEL Acrylic Dome
PERFORMANCE TEST REPORT Rendered to: VELUX America, Inc. PRODUCT: SUN TUNNEL Acrylic Dome Report No: D3964.01-106-31 Report Date: 06/19/14 Test Record Retention Date: 06/03/18 130 Derry Court York, PA
More informationTest Practice for Efficacy Evaluation of Encapsulate Solutions
CRI TEST METHOD 123 TECHNICAL BULLETIN Test Practice for Efficacy Evaluation of Encapsulate Solutions Table of Contents 1.0 Scope... 2 2.0 Referenced Documents... 2 3.0 Terminology... 2 4.0 Significance
More informationIn Search of Standard Reference Materials (SRMs) for ASTM E05 Fire Standards by. Norman Alvares & Harry Hasegawa
In Search of Standard Reference Materials (SRMs) for ASTM E05 Fire Standards by Norman Alvares & Harry Hasegawa First Paragraph of E-691 Tests performed on presumably identical materials in presumably
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SGS GOVMARK TESTING SERVICES, INC. 96 Allen Boulevard, Suite D Farmingdale, NY 11735 Doug Lipp Phone: 631 293 8944 THERMAL Valid To: May 31, 2018 Certificate
More information1.0 INTRODUCTION. Shaw Industries Group 2 SwRI Project No c
1.0 INTRODUCTION This report presents the results of a fire performance evaluation in accordance with the 2011 Edition of National Fire Protection Association (NFPA) Standard 265, Standard Methods of Fire
More informationFUNDERMAX GMBH FIRE TEST REPORT
FUNDERMAX GMBH FIRE TEST REPORT SCOPE OF WORK ASTM E84 TESTING ON 19 MM MAX COMPACT REPORT NUMBER I0002.02-121-24 TEST DATE 01/29/18 ISSUE DATE 02/16/18 RECORD RETENTION END DATE 01/29/22 PAGES 10 DOCUMENT
More informationTECHNICAL BULLETIN Weston Parkway, Cary, North Carolina, Telephone (919) FLAMMABILITY TESTING: A REVIEW BY COTTON INCORPORATED
TECHNICAL BULLETIN 6399 Weston Parkway, Cary, North Carolina, 27513 Telephone (919) 678-2220 TRI 4004 FLAMMABILITY TESTING: A REVIEW BY COTTON INCORPORATED 2004 Cotton Incorporated. All rights reserved;
More informationFirst Revision No. 2-NFPA 90B-2012 [ Section No. 1.3 ] Submitter Information Verification. Committee Statement and Meeting Notes
First Revision No. 2-NFPA 90B-2012 [ Section No. 1.3 ] 1.3 Application. 1.3.1 This standard shall apply to all systems for the movement of environmental air in structures that serve the following, except
More informationIntertek. REPORT NUMBER: SAT-005 ORIGINAL ISSUE DATE: October 29,2008 REVISED DATE: November 19, 2008
Intertek I 0:: o D.. W 0:: I en w I REPORT NUMBER: 3161466SAT-005 ORIGINAL ISSUE DATE: October 29,2008 REVISED DATE: EVALUATION CENTER Intertek Testing Services NA Inc. 16015 Shady Falls Rd. Elmendorf,
More informationTechnical Training International Textiles Training September 2018 Ellen Roaldi Instructor
Technical Training International Textiles Training September 2018 Ellen Roaldi Instructor www.astm.org ASTM D1230 Flammability of Apparel Textiles Scope: This test method covers the evaluation of the flammability
More informationREPORT NUMBER: SAT-001B ORIGINAL ISSUE DATE: February 29, 2016 REVISED DATE:
Page 1 of 10 TEST REPORT REPORT NUMBER: 102317918SAT-001B ORIGINAL ISSUE DATE: February 29, 2016 REVISED DATE: EVALUATION CENTER Intertek Testing Services NA Inc. 16015 Shady Falls Road Elmendorf, TX 78112
More informationPublic Comment No. 1-NFPA [ Section No ]
Page 1 of 7 Public Comment No. 1-NFPA 556-2014 [ Section No. 2.3.1 ] 2.3.1 ASTM Publications. ASTM International, 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA, 19428-2959. ASTM D2859, Standard
More informationISO INTERNATIONAL STANDARD. Reaction to fire tests for floorings Part 1: Determination of the burning behaviour using a radiant heat source
INTERNATIONAL STANDARD ISO 9239-1 Third edition 2010-06-15 Reaction to fire tests for floorings Part 1: Determination of the burning behaviour using a radiant heat source Essais de réaction au feu des
More informationPRODUCT PERFORMANCE TEST REPORT. Report No.: D Test Date: May 29, Rendered to: Natural Light Energy Systems Phoenix, Arizona
Architectural Testing PRODUCT PERFORMANCE TEST REPORT Report No.: D7226.01-121-24 Test Date: May 29, 2014 Rendered to: Natural Light Energy Systems Phoenix, Arizona PRODUCT TYPE: Tubular Daylight Device
More informationReport on Public Input June 2014 NFPA 101
101 PI# 115 SAF-FUR (10.2.1.2) 10.2.1.2 Materials applied directly to the surface of walls and ceilings in a total thickness of less than 1 / 28 in. (0.9 mm) shall not be considered interior finish and
More informationStandard Test Method for the Evaluation of Texture Appearance Retention of Carpets for Minimum Carpet Standards Program 1. Scope
Standard Test Method for the Evaluation of Texture Appearance Retention of Carpets for Minimum Carpet Standards Program 1. Scope 1.1 This practice describes the equipment and operation of the hexapod tumble
More informationFire Test Methods ASTM NFPA UL ISO IEC
Fire Test Methods ASTM NFPA UL ISO IEC D2859 (Standard Test Method for Ignition Characteristics of Finished Textile Floor Covering Materials) E84 (Standard Test Method for Surface Burning Characteristics
More informationIMO Resolution MSC 61 (67) 1996; Annex 1, Part 2. Smoke & Toxicity Test. WF Report Number: Date: 13 th August Test Sponsor:
IMO Resolution MSC 61 (67) 1996; Annex 1, Part 2 Smoke & Toxicity Test WF Report Number: 166040 Date: 13 th August 2007 Test Sponsor: Fiba Tech Industries Ltd. 0249 Page 2 of 13 Bodycote warringtonfire
More informationGUARDIAN FIRE TESTING LABORATORIES, INC.
GUARDIAN FIRE TESTING LABORATORIES INC. Testing & Listing Field Labeling Page 1 of 5 Engineering & Product Certification Services Factory Inspections Guardian Fire Testing Laboratories, Inc. Phone: 716
More informationTech Notes. TESTING PROTOCOL Fire Retardant Gel Coats. INTERPLASTIC CORPORATION Thermoset Resins Divison ISSUE 5
INTERPLASTIC CORPORATION Thermoset Resins Divison ISSUE 5 5 Tech Notes TESTING PROTOCOL Fire Retardant Gel Coats Issue Date: 4/22/2010 Document ID: TN-TS-05A 2010 Interplastic Corporation Testing Protocol
More informationASTM E84-99 ADHERED SURFACE BURNING CHARACTERISTICS
ASTM E84-99 ADHERED SURFACE BURNING CHARACTERISTICS SPANK 9901101 REPORT NO. 75157 Septemer 11, 00 Prepared For: Pollack 150 Varick Street New York, NY 10013 F-316-A 555 76TH STREET S.W., GRAND RAPIDS.
More informationReport on First Revision June 2014 NFPA 101
101 FR500 SAF-FUR (10.2.1.2 and 10.2.1.3) Recommendation: 10.2.1.2 The provisions of Section 10.2.1.1 shall not apply to mmaterials having a total thickness of less than 1/28 in (0.9 mm) that are applied
More informationNational Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:
National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org M E M O R A N D U M TO: FROM: NFPA Technical Committee on Merchant Vessels
More informationTEST REPORT EVALUATION CENTER Intertek Testing Services NA Ltd Brigantine Drive Coquitlam, B.C. V3K 7C1
REPORT NUMBER: 101145164COQ-005 ORIGINAL ISSUE DATE: April 25, 2013 TEST REPORT EVALUATION CENTER Intertek Testing Services NA Ltd. 1500 Brigantine Drive Coquitlam, B.C. V3K 7C1 RENDERED TO udecor Inc.
More informationUV Weather Resistance Test Chambers
UV Weather Resistance Test Chambers Introduction The UV Aging test chamber is used for testing light fastness and aging resistance non-metallic materials. NAE UV Climate test chamber uses 8 UV340 or UV313
More informationTFI Report Reaction to fire test
TFI Report 450740-07 Reaction to fire test For the classification according to EN 13501-1:2010 Customer GÜLSEVEN HALI GÜLSEVEN TEKSTIL KIMYA GIDA SAN. TIC. LTD. STI Ahi Evran Sanayi Sitesi Istiklal Caddesi
More informationRENDERED TO. Laminam S.P.A. Via Ghiarola Nuova Fiorano Modenese Italy
REPORT NUMBER: 100900037COQ-002 ORIGINAL ISSUE DATE: October 10, 2012 TEST REPORT EVALUATION CENTER Intertek Testing Services NA Ltd. 1500 Brigantine Drive Coquitlam, BC V3K 7C1 RENDERED TO Laminam S.P.A.
More informationRENDERED TO Vipco Industries Inc th Avenue SE Calgary, AB T2C 0B3
REPORT NUMBER: 101207560COQ-001b ORIGINAL ISSUE DATE: June 12, 2013 TEST REPORT EVALUATION CENTER Intertek Testing Services NA Ltd. 1500 Brigantine Drive Coquitlam, B.C. V3K 7C1 RENDERED TO Vipco Industries
More informationMaterials Testing by Gregory Havel
Materials Testing by Gregory Havel July 24, 2017 One of the most common tests cited in the technical bulletins on building materials is ASTM E84 Standard Method of Test of Surface Burning Characteristics
More informationStandard Laboratory Test Practice For Measurement Of Surface Appearance Change Of Textile Floor Covering As A Result Of The Vacuuming Process
CRI TM 114-110901 Standard Laboratory Practice for Carpet Surface Appearance Change Due To Vacuuming P.O. Box 2048 Dalton Georgia 30722-2048 706.278.3176 carpet-rug.org Standard Laboratory Test Practice
More informationIMO Resolution MSC 61(67): Annex 1: Part 2
Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 (0 1925 655116 F : +44 (0) 1925 655419 E : warrington@exova.com W: www.exova.com IMO Resolution MSC 61(67): Annex 1: Part
More informationConsultant Specification AGILE Wireless Fire Detection System
Contents Scope of Work... 2 The EN54 Part 2 & 4 Fire System... 2 Standards... 2 Wireless Intelligent Photoelectric Smoke Detector Specification... 4 Wireless Intelligent Thermal Heat Detector Specification...
More informationFlammability Test Results
Kmlex Aviation Inc. 265 Diab, Ville St-Laurent, Quebec, Canada, H4S 1E7 Tel: 514-626-1254, Fax: 514-784-131 Flammability Test Results FAR 25.853 / AWM 525.853 (a) Appendix F Part I, (a) 1, (i) 6 second
More informationBS 476: Part 7: 1997 on K-Flex IN Clad Foil. Prepared for: L'Isolante K-Flex Srl Via Leonardo da Vinci, RONCELLO (MB) Italy
BS 476: Part 7: 1997 on K-Flex IN Clad Foil Prepared for: L'Isolante K-Flex Srl Via Leonardo da Vinci, 36 20877 RONCELLO (MB) Italy 30 th October 2012 0578 Page 1 of 6 Prepared on behalf of BRE Global
More informationRetardantsInc. The Decision You Make May Save A Life! 123 Columbia Court North Suite 201 Chaska, MN 55318
EST. 1860 RetardantsInc. The Decision You Make May Save A Life! 123 Columbia Court North Suite 201 Chaska, MN 55318 952-448-7377 FAX:952-448-2613 Fire Retardant HOT LINE 1-800-913-9385 e-mail: info@fireretardantsinc.com
More informationFRANCE M & F RANKING ACCORDING TO NF F
FRANCE M & F RANKING ACCORDING TO NF F 16-101 CREPIM / http://www.crepim.com 1 The actual classification used by French regulations for the classification of fire behaviour of materials/component is described
More informationPerformance Rating of Active Chilled Beams
AHRI Standard 1241 (SI) 2016 Standard for Performance Rating of Active Chilled Beams IMPORTANT SAFETY RECOMMENDATIONS AHRI does not set safety standards and does not certify or guarantee the safety of
More informationFirst Revision No. 6-NFPA [ Section No. 2.2 ]
Page 1 of 18 First Revision No. 6-NFPA 555-2014 [ Section No. 2.2 ] 2.2 NFPA Publications. National Fire Protection Association, 1 Batterymarch Park, Quincy, MA 02169-7471. NFPA 12, Standard on Carbon
More informationFire Performance of Translucent Systems
Fire Performance of Translucent Systems ASTM E-108 Burning Brand Test on Quadwall Class A Approved Light Transmitting Plastics Fire Test Performance Meets Building Code Requirements: Self-Ignition ASTM
More informationCone Calorimeter. (ISO 5660 ASTM E 1354) The most comprehensive bench scale fire test THE BENCHMARK IN FIRE TESTING
Cone Calorimeter (ISO 5660 ASTM E 1354) The most comprehensive bench scale fire test THE BENCHMARK IN FIRE TESTING Cone Calorimeter (ISO 5660 ASTM E 1354) The most comprehensive bench scale fire test The
More informationWe Identify and S.T.O.P. Your Noise Problems
ASTM E-84 TESTING FOR MANUFACTURER, RENDERED TO: Acoustical Surfaces Inc. 123 Columbia Court North, Suite 201 Chaska, MN 55318 Noise S.T.O.P. Fabrisorb Acoustical Wall Panels TESTED: OCTOBER 3, 2002 October
More informationReported Fires in High-Rise Structures in Selected Occupancies with and without Automatic Extinguishing Systems by Extent of Smoke Damage
Reported Fires in High-Rise Structures in Selected Occupancies with and without Automatic Extinguishing Systems by Extent of Smoke Damage Marty Ahrens Fire Analysis and Research Division National Fire
More informationASTM F25 SEMINAR Fire Testing for SOLAS and Navy Vessels New Test Procedures and Materials Approval Process
ASTM F25 SEMINAR Fire Testing for SOLAS and Navy Vessels New Test Procedures and Materials Approval Process 2010 IMO FTP Code Revisions Parts 2, 5, 7, 8, 9 & 10 Presented by: Juan Manuel Flores, P.E. Date:
More informationBURNING BRAND PERFORMANCE TEST REPORT. Rendered to: VELUX AMERICA, INC. SERIES/MODEL: TGF/TGR (Acrylic Dome) VELUX SUN TUNNEL
BURNING BRAND PERFORMANCE TEST REPORT Rendered to: VELUX AMERICA, INC. SERIES/MODEL: TGF/TGR 022 0000 (Acrylic Dome) VELUX SUN TUNNEL ACCESSORY PRODUCTS: Tubular Skylight with ZTA 022 000090 9" Turrets
More informationRetardantsInc. The Decision You Make May Save A Life! 123 Columbia Court North Suite 201 Chaska, MN 55318
EST. 1860 RetardantsInc. The Decision You Make May Save A Life! 123 Columbia Court North Suite 201 Chaska, MN 55318 952-448-7377 FAX:952-448-2613 Fire Retardant HOT LINE 1-800-913-9385 e-mail: info@fireretardantsinc.com
More informationForbo Flooring Attn. Mr. A. Tijhof Postbus AA Krommenie. Report. Sponsor : Contractor, manufacturer : Forbo Flooring. Lot. No. : 66869/3877.
Return address: P.O. box 337, 7500 AH Enschede, TNO Centre for Textile Research Ariënsplein 3 7511 JX ENSCHEDE Forbo Flooring Attn. Mr. A. Tijhof Postbus 13 1560 AA Krommenie Report Sponsor : Contractor,
More informationCAN THE CONE CALORIMETER BE USED TO PREDICT FULL SCALE HEAT AND SMOKE RELEASE CABLE TRAY RESULTS FROM A FULL SCALE TEST PROTOCOL?
CAN THE CONE CALORIMETER BE USED TO PREDICT FULL SCALE HEAT AND SMOKE RELEASE CABLE TRAY RESULTS FROM A FULL SCALE TEST PROTOCOL? Marcelo M. Hirschler GBH International, USA ABSTRACT The results of three
More informationThis document is a preview generated by EVS
INTERNATIONAL STANDARD ISO 11810 Second edition 2015-12-15 Lasers and laser-related equipment Test method and classification for the laser resistance of surgical drapes and/or patient protective covers
More informationCLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009
CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN 13501-1:2007+A1:2009 Sponsor Prepared by P.O. Box 70 NL-5750 AB DEURNE Efectis Nederland BV Lange Kleiweg 5 P.O. Box 1090 NL-2280 CB
More informationSECTION REGULATORY REQUIREMENTS. A. Relationship between Code, Ordinances, Standards and Contract Documents
SECTION 01410 PART I - GENERAL 1.01 SECTION INCLUDES A. Relationship between Code, Ordinances, Standards and Contract Documents B. Applicable Codes, Laws and Ordinances C. Project Inspections D. Office
More informationUnderstanding total measurement uncertainty in power meters and detectors
Understanding total measurement uncertainty in power meters and detectors Jay Jeong, MKS Instruments. Inc. INTRODUCTION It is important that users of calibrated power meters and detectors understand and
More informationFire Risk and CODE Compliance For Fabric Wrapped Acoustic Panels
Fire Risk and CODE Compliance For Fabric Wrapped Acoustic Panels Historical Large Loss Fires With Combustible Interior Finishes Cocoanut Grove, Boston, 1942-492 fatalities Winecoff Hotel, Atlanta GA, 1946-119
More informationTECHNICAL SPECIFICATION
TECHNICAL SPECIFICATION IEC TS 62788-7-2 Edition 1.0 2017-09 colour inside Measurement procedures for materials used in photovoltaic modules Part 7-2: Environmental exposures Accelerated weathering tests
More informationAustralian Standard. Methods for fire tests on building materials, components and structures
AS 1530.3 1989 Australian Standard Methods for fire tests on building materials, components and structures Part 3: Simultaneous determination of ignitability, flame propagation, heat release and smoke
More informationCLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009
P.O. Box 554 2665 ZN Bleiswijk Brandpuntlaan Zuid 16 2665 NZ Bleiswijk The Netherlands +31 88 3473 723 nederland@efectis.com OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN 13501-1:2007+A1:2009 Classification
More informationTest Report. Appliance EMF Testing
Project: 11014506A Date: November 6, 2015 Model: 120V_WWF13NW Test Report On Appliance EMF Testing Copyright 2005 UL LLC UL LLC authorizes the above-named company to reproduce this Report provided it is
More informationInvestigation of the Potential Use of Blue Light in Forward Scattering Optical Smoke Chambers to Detect all UL217 Fires in the New Standard
Investigation of the Potential Use of Blue Light in Forward Scattering Optical Smoke Chambers to Detect all UL217 Fires in the New Standard David Richardson, Daniel O Shea, Stephen Daniels, Michael Byrne
More informationTest Report: ICL/H18/9039 Rev 1
Interscience Fire Laboratory Building 63 Haslar Marine Technology Park Haslar Road, Gosport Hampshire PO12 2AG United Kingdom Tel. : +44 (0) 20 8692 5050 Fax.: +44 (0) 20 8692 5155 Email: firetesting@intersciencecomms.co.uk
More informationPERFORMANCE TEST REPORT. Rendered to: PALRAM AMERICAS, INC. PRODUCT: Clear Palsun TYPE: Polycarbonate
PERFORMANCE TEST REPORT Rendered to: PALRAM AMERICAS, INC. PRODUCT: Clear Palsun TYPE: Polycarbonate Report No: C7626.1-16-31 Report Date: 5/8/13 Test Record Retention Date: 5/8/17 PERFORMANCE TEST REPORT
More informationON FIRE OF QUALITY: SINCE 1972 A CONTINUUM
A CONTINUUM OF QUALITY: ON FIRE SINCE 1972 The Govmark Organization, Inc. Instrument Division (the largest USA manufacturer of fire and flammability test instrumentation worldwide) has been producing high
More informationElectrode#1582. Product Details. Colors. Designed with the technology-age in mind, Electrode's "circuitry" will be a shocking hit!
Electrode#1582 Designed with the technology-age in mind, Electrode's "circuitry" will be a shocking hit! Product Details Collection: Product Type: Kaleidoscope 100% STAINMASTER Nylon Carpet Pattern Repeat:
More informationLAB ID and/or LABORATORY NAME: ASSESSOR NAME: ELECTRET by Voltametry. Method Number: ELAP method number SOP Number: Revision Number: SOP Date:
LAB ID and/or LABORATORY NAME: ASSESSOR NAME: DATE: ELECTRET by Voltametry Method Number: ELAP method number 7034 SOP Number: Revision Number: SOP Date: Personnel / Data Records observed: General LLD:
More informationCLT Adhesive Tests in Support of Mass Timber Buildings
CLT Adhesive Tests in Support of Mass Timber Buildings DES604 Jason Smart, P.E. Manager, Engineering Technology American Wood Council Sam Francis, C.B.O. Senior Director, National Programs American Wood
More informationAllianz Engineering Inspection Services Ltd. Electrical Services. Product Information
Allianz Engineering Inspection Services Ltd Electrical Services Product Information Electrical Testing and Inspection Services The Electricity at Work Regulations (EaWR) states that all electrical systems
More informationE-BEAM DRUM TRANSFER: PROCESS TO ELECTRON IRRADIATE A PSA IN THE ABSENCE OF A BACKING.
E-BEAM DRUM TRANSFER: PROCESS TO ELECTRON IRRADIATE A IN THE ABSENCE OF A BACKING. James DiZio, Senior Research Specialist, 3M, St. Paul, MN Douglas Weiss, Senior Research Specialist, 3M, St. Paul, MN
More informationEXTINGUISHING SYSTEM DETECTION AND CONTROL
GAP.13.0.1 A Publication of Global Asset Protection Services LLC EXTINGUISHING SYSTEM DETECTION AND CONTROL INTRODUCTION Extinguishing systems require prompt detection systems so they operate quickly and
More informationPRIMATECH WHITE PAPER PROCEDURE FOR DUST HAZARD ANALYSIS (DHA)
PRIMATECH WHITE PAPER PROCEDURE FOR DUST HAZARD ANALYSIS (DHA) Glossary of Terms Combustible dust: A finely divided combustible particulate solid that presents a flash-fire hazard or explosion hazard when
More informationFirst Revision No. 6-NFPA 90A-2012 [ Chapter NFPA ] Submitter Information Verification. Committee Statement and Meeting Notes
First Revision No. 6-NFPA 90A-2012 [ Chapter NFPA ] 4.3.11.5.5 Materials within a raised floor plenum exposed to the airflow shall be (a) noncombustible or (b) exhibit a maximum flame spread index of 25
More informationAbrasion Resistance of Fluoropolymer and polyester Coatings
Abrasion Resistance of Fluoropolymer and polyester Coatings British Standards British Standard 476 refers to fire tests on building materials and structures. The parts of this standard that are of most
More informationSoot Mitigation Strategies
Soot Mitigation Strategies Walter P. Drosjack, P.E. David L. Oar, P.E., F.S.F.P.E. 32 nd Nuclear Air Cleaning Conference June 18-19, 2012 Who is URS? URS is one of the world s largest engineering, construction
More informationMATERIAL EVALUATION REPORT STATIC DECAY, RESISTANCE AND TRIBOELECTRIC CHARGE GENERATION TESTING OF MERINO ESD LAMINATE SAMPLES MERINO INDUSTRIES, INC.
MATERIAL EVALUATION REPORT STATIC DECAY, RESISTANCE AND TRIBOELECTRIC CHARGE GENERATION TESTING OF MERINO ESD LAMINATE SAMPLES MERINO INDUSTRIES, INC. JUNE 6, 2011 1 MATERIAL EVALUATION REPORT Static Decay,
More informationREPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045
REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045 FOR THE SCOPE OF ACCREDITATION UNDER NVLAP LAB CODE 100402-0. Project No. G101030158 Date: February 26, 2013 REPORT NO. 101030158CRT-001 TEST OF ONE LED
More informationCLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009
P.O. Box 554 2665 ZN Bleiswijk Brandpuntlaan Zuid 16 2665 NZ Bleiswijk The Netherlands +31 88 3473 723 nederland@efectis.com OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN 13501-1:2007+A1:2009 Classification
More information