STilE/DIVISION OF SHAW DESCRIPTION OF TEST SAMPLE

Size: px
Start display at page:

Download "STilE/DIVISION OF SHAW DESCRIPTION OF TEST SAMPLE"

Transcription

1 Professional DESCRIPTION OF TEST SAMPLE - IDENTIFICATION BACKINC connect EW24 LOOP Pile GENERAL PRINCIPLE This method is designed to assess the static propensity of flooring material by controlled laboratory simulation of conditions which are known from experience to be strongly contributory to excessive accumulation of static charges. A flooring material preconditioned to equilibrium at controlled atmospheric conditions is walked on by a test subject in a specified manner with specified shoe soles. The static charges which build up on the tester are monitored continuously by a recorder. A neolite shoe sole has been chosen as the primary reference material because its static performance is much like that of many common leathers. It is a commonly used shoe sole material and can be easily cleaned, while its chemical and physical properties are quite uniform. A chrome tanned leather shoe sole has been chosen for a secondary reference material because it is representative of a certain class of leathers whose performance differs significantly from that of neolite soles on certain carpet fiber. statistically, chrome tanned leather comprises a very small percentage of the shoe sole market, but must be considered in critical applications. accreditation does I]ot constitute an endorsement, certification, or approval by NIST or any agency of the Ul]ited States Government for the product tested. ~--~~- This facility is accredited by the National Voluntary labora19ry Accreditation Program for the specific scope of accreditation under lab Code., This I' This constituted report.is authorities. provided for This the report exclusive applies use only of the to those c!ient samples to whom tested it is addressed. andi~not ~ssarily It ~ay be il]dicative used in its of entirety apparently to gain )dentital product 01: similar acc!'ptance prod,!cts. from duly This ~ r"'p rt, or the name of Professional laboratory,, shall not be used under any circumstance In advertising to the general public ~ ;I 714 Glenwood Place Dalton, GA Fax:

2 Professional TEST NUMBER DATE 04/04/03 PACE 2 of 2 DESCRIPTION OF TESLSAMPLE IDENnFICA TION connect ~ EW24 Loop Pile MAXIMUM VOL race DAY 1 TEST step Test/Neolite sale DAY KV -0.5 KV -0.6 KV -1.4 KV -1.3 KV TEST II: Scuff Test/Neolite Sale "1.2 KV TEST III: step Test/Leather sole +0.4 KV KV KV TEST IV: Scuff Test/Leather MAXIMUM Sole AVERAGE AVERAGE VOLTAGE +0.4 KV KV +1.1 KV NEG 1.3 KV "771e resultsof this test relate to the sampleof flooring material tested. It's static performance may be altered in serviceasa result of wea'j!1'ing, cleaning, emperature,relative humidity, etc..." APPROVED BY:,.This facilit,yis accredited by the National Voluntary lliboratory Accreditation Program for the specifil scope of a=editationunder lab Code This accredltationdoes not constitute an endorsement, certification; or approval by NISTor any agencyof J;e United States Governmentfor the product tested. This '!'POrt is provided for the exclusiveuse of the client to whom it is addressed. It may be used in its entirety to gain product acceptancefrom duly constituted authorities. This repoo:tapplies only 10 those samples{ested and is not necessarilyindicative of apparently identical or similar products. This report, or the name of Professionall;Jboratf'!'Y,, shall not be used under anycircumstancein advertisingto the generalpublic. 714 Glenwood Place Dalton, GA Fax: ?-':'C""

3 Professional DESCRIPTION OF TEST SAMPLE IDENTIFICATION connect EW24 LOOp Pile FLAMING 166 GENERAL PRINCIPLE This procedure is designed to measure the specific optical density of smoke generated by the test specimen within a closed chamber. Each specimen is exposed to an electrically heated radiant-energy source positioned to provide a constant irradiance level of 2.5 watts/square cm on the specimen surface. Measurements are recorded through a photometric system employing a vertical beam of light and a photo detector positioned to detect the attenuation of light transmittance caused by smoke accumulation within the chamber. The light transmittance measurements are used to calculate specific optical density, a quantitative value which can be factored to estimate the smoke potential of materials. Two burning conditions can be simulated by the test apparatus. The radiant heating in the absence of ignition is referred to as the Non-Flaming Mode. A flaming combustion in the presence of supporting radiation constitutes the Flaming Mode. This facility is accredited by1he Nation,,1 Voluntary l4boratory Accreditation Program for the specific scope of accreditation under l4b Code This accreditation does not constitute an endorsement, certification, or approval by NIST or any agency of the United States Government for the product tested. T~is report is provided for the exclusive use of the client to whom.it is addressed. It maybe used in its entirety to gain product acceptance frqm duly constituted authorities. This.reportapplies only to those samples tested and is not necessarily indicativ~ of apparently identical or similar products. This report, or the name of Professional ~atory,, shall not be used under any circumstance in advertising to the general public. 714 Glenwood Place Dalton, GA Fax:

4 Professional TEST NUMBER DATE 04/04/03 PACE 2 Of 2 DESCRIPnONOF IDENTIFICA TION connect TEST SAMPLE EW24 LOop Pile CONDITIONS PREDRYINC OF TEST SAMPLE CONDITIONINC OF TEST SAMPLE 24 Hours at 140 degrees F 24 Hours at 70 degrees F and 50% relative humidity This facility is accredited by the National Voluntary~boratot Accreditation Programfor the speci,.{ scope of accreditation under~bcode This accreditati(>ndoes not constitute an endorsement, certification, or approva! by NISTor any agencyoh~e United States Governmentfor the product tested. This rep(>rt is provided for the exclusive use of the clien~ to whom it is addressed. It may be used in its entirety to gaihproduct acceptancefrom duly constituted authorities. This rep(>rtappjiesonly to those samples tested and is not necessari.lylndicativeof apparently identical or similar pr~uct$. This report, or the name of professiol]~1~boratory,, shall not be used under ally circumstance in adv!'rtisingto the generalpublic Glenwood Place Dalton, GA Fax:

5 Professional D ESCR I PT 1.0 NOFTESTSAM PLE IDENTIFICATION connect EW24 LOOp Pile criteria set forth in the report. An)' produce diffciedt resui8. AVERACECRITICAL RADIANT FLUX 65 watts/square Cm GENERAL PRINCIPLE This procedure is designed to measure the critical radiant flux at flame out, of horizontally mounted floor covering systems exposed to a flaming ignition in a test chamber which provides a graded radiant heat energy environment. The imposed radiant flux simulates the thermal radiation levels likely to impinge on the floors of a building whose upper surfaces are heated by flames of compartment. The test result is an average critical radiant flux (watts/square cm) which indicates the level of radiant heat energy required to sustain flame propagation in the flooring system. Theoretically, if a room fire does not impose a radiant flux that exceeds this critical level on a corridor floor covering system, flame spread will not occur. Thi~ facility is accredited by the National Volunt~~boratory Accreditltion Program for the spec.ific scope of accreditation under lab Code This ~ ~ ' ac~reditlt!ondoes ~':::.\f? ~ This report IS provided for the exclusive use of,he client to whom It IS addressed.. It may be used In.Its entirety to gain produ!:! acc~ce from duly U\J\:/ ~ ~ constituted authorities, This report applies only to those samples tested and is not necessarily indicative of~parently identical or similar products.. This report; or the name of Professional laboratory,.. shall not be used under any circumstance in ady(ertising to the general public. 714 Glenwood Place Dalton, GA Fax:

6 Professional TES.NUMBER DATE 04/04/03 PAGE 2 of 2 D ESCRIPTIONOFTESTSAM IDENTIFICA TION Connect P LE EW24 LOOp Pile BACKINC crit~ri.a se,t to]..:1 ~th-e:-report..' :ny produce eredt ts. TEST DATA DISTANCEBURNED TIME TO FLAME OUT CRJTJCALRAD JANTFLUX SPEC.lMEN1 32 cm 15 minutes 64watts/sq cm SPECIMEN 2 28 cm 17 minutes 68 watts/sq cm SPECIMEN 3 32 cm 18 minutes 64watts/sq cm AVERAGE CRITICAL RADIANT FLUX STANDARD..DEV1AT1ON 65 watts/square cm 02watts/squarecm COEFFICIENT OF VARIATION 4% APPROVED BY: This facility is a~redited by the National Voluntary Accreditation Program for the specific scope of accreditation under Lab Code This accreditationdoes not constitute an endorsement..certification, or approval by Ni~Tor any agencyof the United StatesGovernment for the product t"sted. This report is provided for the exclusive use of the client to whom itis addressed. It may be used in its entirety.to gain product acceptancefrom duly cohstituted authorities. This report applies only to those sampl"s tested and is not necessarily indicative of apparently identical (>rsimilar products. This report, or the!jameof ProfessionalTo;sting,lnc., shaff not be ~sed under anycircumstanc" In advertisingto the general public 714 Glenwood PJace Dalton, GA Fax:

~ 0."0... DESCRI PT ION OF TEST SAM PLE

~ 0.0... DESCRI PT ION OF TEST SAM PLE TEST METHOD CONDUCTED AATCC Test Method 134-1996 Electrostatic propensity of carpets IDENTIF.lCATION ~ 0."0... DESCRI PT ION OF TEST SAM PLE...c" 50912 Cu Itu re ROLL.. CONSTRUCT.lON Textured Loop Pile

More information

SHAW CONTRACT DESCRIPTION OF TEST SAMPLE

SHAW CONTRACT DESCRIPTION OF TEST SAMPLE TEST METHOD CONDUCTED AATCC Test Method 134-1996 Electrostatic propensity of carpets DESCRIPTION OF TEST SAMPLE IDENTIFICATION SAO20 GloW UPAT ROLL CONSTRUCTION 465883J Multi-Level cut & Loop Pile FIBER

More information

STilE/DIVISION OF SHAW DESCRI.P TION 0 FT E STSAMP L E

STilE/DIVISION OF SHAW DESCRI.P TION 0 FT E STSAMP L E CLIENT TEST NUMBER 0081483 DATE 12/02/03 PACE 1 of 2 DESCRI.P TION 0 FT E STSAMP L E IDENTIFICATION 59358 Color Play EW 24 -,. c'..-.. B- ACKINC REFERENCE GENERAL PRINCIPLE This method is designed to assess

More information

Inc. PACE 1 of 2. Testing Laboratory. AA TCC Test Method Electrostatic Propensity of Carpets TEST M ET"ODCON D UCTED

Inc. PACE 1 of 2. Testing Laboratory. AA TCC Test Method Electrostatic Propensity of Carpets TEST M ETODCON D UCTED TEST REPORT PACE 1 of 2 -~.- TEST M ET"ODCON D UCTED AA TCC Test Method 134-1996 Electrostatic Propensity of Carpets I.DENTI.FIQADON 59371 peto II 26 EW 24 COLOR ROLL -" CONSTRUCTION BACKING REFERENCE

More information

STilE/DIVISION OF SHAW

STilE/DIVISION OF SHAW ~ Professional CLIENT TEST REPORT STilE/DIVISION OF SHAW fdentiffcatfon COLOṘ SO-U3577 CONSTRUCTION Textured LOOp Pile FIBER - BACKINO ~ REFERENCE TEST NO: 111703-32 MAXIMUM VOLTAGE NEG 2.8 KV CENERAL

More information

DESCRIPTIO NOFTESTSAMP

DESCRIPTIO NOFTESTSAMP esting aboratory rofessional TEST REPORT nc. TEST METHOD CONDUCTED AATCC Test Method 134-1996 Electrostatic Propensity of carpets DESCRIPTIO NOFTESTSAMP.. IDENTIFICATION 60283 Ambition II L E ROLL.. CONSTRUCTjON

More information

ASTM E662 TESTING FOR COLE MOTORSPORTS/CM RACING PRODUCTS ON WINDSHIELD TEAROFFS ON ¼ GLASS VTEC # TESTED: MARCH 27, 2009

ASTM E662 TESTING FOR COLE MOTORSPORTS/CM RACING PRODUCTS ON WINDSHIELD TEAROFFS ON ¼ GLASS VTEC # TESTED: MARCH 27, 2009 ASTM E662 TESTING FOR COLE MOTORSPORTS/CM RACING PRODUCTS ON WINDSHIELD TEAROFFS ON ¼ GLASS VTEC #100-3191-1 TESTED: MARCH 27, 2009 April 2, 2009 Client: Attention: Cole Motorsports/CM Racing Products

More information

TEST REPORT DATE: TEST NUMBER: DESCRIPTION OF TEST SAMPLE

TEST REPORT DATE: TEST NUMBER: DESCRIPTION OF TEST SAMPLE Professional Testing Laboratory, Inc. TEST REPORT DATE: 06-16-2014 TEST NUMBER: 0209182 CLIENT Artistry Hardwood Flooring TEST METHOD CONDUCTED IDENTIFICATION CONSTRUCTION REFERENCE ASTM E648 Standard

More information

EnviroScape Mural. pre-pasted printable wallcovering material. Choose your GREEN resource from a leading solutions provider.

EnviroScape Mural. pre-pasted printable wallcovering material. Choose your GREEN resource from a leading solutions provider. by NEENAH EnviroScape Mural pre-pasted printable wallcovering material EnviroScape Mural is a PVC free wall, window or hard surface scaping product that is pre-pasted with a water activated adhesive backing

More information

BS EN ISO : Fire Tests For Determination Of The Burning Behaviour of Floorings. WF Report Number. Date: 16 th November 2009.

BS EN ISO : Fire Tests For Determination Of The Burning Behaviour of Floorings. WF Report Number. Date: 16 th November 2009. Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 (0) 1925 655 116 F : +44 (0) 1925 655 419 E : warrington@exova.com W: www.exova.com BS EN ISO 92391: 2002 Fire Tests For

More information

BS EN ISO : 2010

BS EN ISO : 2010 Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 (0 1925 655116 F : +44 (0) 1925 655419 E : warrington@exova.com W: www.exova.com BS EN ISO 92391: 2010 Fire Tests For Determination

More information

ASTM E 662 Rate of Smoke Generation of OXIFREE TM198"

ASTM E 662 Rate of Smoke Generation of OXIFREE TM198 ELECTRONIC COPY ASTM E 662 Rate of Smoke Generation of OXIFREE TM198" A Report To: Oxifree Global LLC 22955 State Highway 249, Suite 6 Tomball, TX 77375 USA Phone: (281) 251-7171 E-mail: ed.hall@oxifree.com

More information

TEST REPORT. NFPA 253 / ASTM E648-14c Standard Test Method for Critical Radiant Flux of Floor-Covering Systems Using a Radiant Heat Energy Source

TEST REPORT. NFPA 253 / ASTM E648-14c Standard Test Method for Critical Radiant Flux of Floor-Covering Systems Using a Radiant Heat Energy Source NFPA 253 / ASTM E648-14c Standard Test Method for Critical Radiant Flux of Floor-Covering Systems Using a Radiant Heat Energy Source TEST REPORT Kolay 5mm 20mil Wear Layer LVT with Fiberglass Core Project

More information

BS EN ISO : 2010

BS EN ISO : 2010 Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 (0 1925 655116 F : +44 (0) 1925 655419 E : warrington@exova.com W: www.exova.com Fire Tests For Determination Of The Burning

More information

BS EN ISO : 2010

BS EN ISO : 2010 Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 (0 1925 655116 F : +44 (0) 1925 655419 E : warrington@exova.com W: www.exova.com BS EN ISO 92391: 2010 Fire Tests For Determination

More information

BCTC CARPET TECHNICAL CENTRE

BCTC CARPET TECHNICAL CENTRE Wira House West Park Ring Road Leeds, LS16 6QL Tel: +44 (0)113 259 1999 Fax: +44 (0)113 278 0306 Web: http://www.bttg.co.uk/bctc Email: CSLeeds@bttg.co.uk 7 September 2010 Page 1 of 7 Client: Rectory Farm

More information

ISO INTERNATIONAL STANDARD. Reaction to fire tests for floorings Part 1: Determination of the burning behaviour using a radiant heat source

ISO INTERNATIONAL STANDARD. Reaction to fire tests for floorings Part 1: Determination of the burning behaviour using a radiant heat source INTERNATIONAL STANDARD ISO 9239-1 Third edition 2010-06-15 Reaction to fire tests for floorings Part 1: Determination of the burning behaviour using a radiant heat source Essais de réaction au feu des

More information

REPORT NUMBER: SAT-001B ORIGINAL ISSUE DATE: February 29, 2016 REVISED DATE:

REPORT NUMBER: SAT-001B ORIGINAL ISSUE DATE: February 29, 2016 REVISED DATE: Page 1 of 10 TEST REPORT REPORT NUMBER: 102317918SAT-001B ORIGINAL ISSUE DATE: February 29, 2016 REVISED DATE: EVALUATION CENTER Intertek Testing Services NA Inc. 16015 Shady Falls Road Elmendorf, TX 78112

More information

ASTM E 662 Rate of Smoke Generation of "Moniflex as manufactured by Isoflex AB"

ASTM E 662 Rate of Smoke Generation of Moniflex as manufactured by Isoflex AB UNCONTROLLED ELECTRONIC COPY ASTM E 662 Rate of Smoke Generation of "Moniflex as manufactured by Isoflex AB" A Report To: Ciucevich 7200 Vermilion Ct. Wake Forest, NC 27587 USA Phone: (919) 570-291 E-mail:

More information

Analysis Report

Analysis Report Prestige Carpets bvba Dhr. Dirk Santens Klein Frankrijk 38 9600 RONSE Your notice of Your reference Date 19-06-2013 24-07-2013 Required tests : Identification number T1309624 Information given by the client

More information

ISO INTERNATIONAL STANDARD. Reaction to fire tests for floorings Part 1: Determination of the burning behaviour using a radiant heat source

ISO INTERNATIONAL STANDARD. Reaction to fire tests for floorings Part 1: Determination of the burning behaviour using a radiant heat source INTERNATIONAL STANDARD ISO 9239-1 Third edition 2010-06-15 Reaction to fire tests for floorings Part 1: Determination of the burning behaviour using a radiant heat source Essais de réaction au feu des

More information

FUNDERMAX GMBH FIRE TEST REPORT

FUNDERMAX GMBH FIRE TEST REPORT FUNDERMAX GMBH FIRE TEST REPORT SCOPE OF WORK ASTM E84 TESTING ON 19 MM MAX COMPACT REPORT NUMBER I0002.02-121-24 TEST DATE 01/29/18 ISSUE DATE 02/16/18 RECORD RETENTION END DATE 01/29/22 PAGES 10 DOCUMENT

More information

FABRITRAK SYSTEMS, INC. FIRE TEST REPORT

FABRITRAK SYSTEMS, INC. FIRE TEST REPORT FABRITRAK SYSTEMS, INC. FIRE TEST REPORT SCOPE OF WORK ASTM E84 TESTING ON POLYESTER INFILL REPORT NUMBER H5200.01-121-24 TEST DATE 08/31/17 ISSUE DATE 09/20/17 RECORD RETENTION END DATE 08/31/21 PAGES

More information

M E M O R A N D U M. Diane Matthews, Administrator, Technical Projects. NFPA 101 First Draft Letter Ballot (A2014)

M E M O R A N D U M. Diane Matthews, Administrator, Technical Projects. NFPA 101 First Draft Letter Ballot (A2014) National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169 7471 Phone: 617 770 3000 Fax: 617 770 0700 www.nfpa.org M E M O R A N D U M TO: FROM: NFPA Technical Committee on Furnishings

More information

SIGMADEK, LTD. FIRE TEST REPORT

SIGMADEK, LTD. FIRE TEST REPORT SIGMADEK, LTD. FIRE TEST REPORT SCOPE OF WORK ASTM E84 TESTING ON ALUMINUM EXTRUSION DECK BOARD C/W PORCELAIN TILE INSERT REPORT NUMBER H5331.01-121-24 TEST DATE 09/13/17 ISSUE DATE 10/03/17 RECORD RETENTION

More information

IMO Resolution MSC 61 (67) 1996; Annex 1, Part 2. Smoke & Toxicity Test. WF Report Number: Date: 13 th August Test Sponsor:

IMO Resolution MSC 61 (67) 1996; Annex 1, Part 2. Smoke & Toxicity Test. WF Report Number: Date: 13 th August Test Sponsor: IMO Resolution MSC 61 (67) 1996; Annex 1, Part 2 Smoke & Toxicity Test WF Report Number: 166040 Date: 13 th August 2007 Test Sponsor: Fiba Tech Industries Ltd. 0249 Page 2 of 13 Bodycote warringtonfire

More information

Standard Laboratory Test Practice For Efficacy Evaluation of Interim. Carpet Maintenance Systems

Standard Laboratory Test Practice For Efficacy Evaluation of Interim. Carpet Maintenance Systems P.O. Box 2048 Dalton Georgia 30722-2048 706.278.3176 carpet-rug.org CRI TM 122 Standard Laboratory Test Practice for Efficacy Evaluation of Interim Carpet Maintenance Systems Standard Laboratory Test Practice

More information

Test Report. Appliance EMF Testing

Test Report. Appliance EMF Testing Project: 11014506A Date: November 6, 2015 Model: 120V_WWF13NW Test Report On Appliance EMF Testing Copyright 2005 UL LLC UL LLC authorizes the above-named company to reproduce this Report provided it is

More information

GUARDIAN FIRE TESTING LABORATORIES, INC.

GUARDIAN FIRE TESTING LABORATORIES, INC. GUARDIAN FIRE TESTING LABORATORIES INC. Testing & Listing Field Labeling Page 1 of 5 Engineering & Product Certification Services Factory Inspections Guardian Fire Testing Laboratories, Inc. Phone: 716

More information

Analysis Report

Analysis Report Forbo Flooring Coral nv Dhr. Jan van Galen Postbus 17 1560 AA KROMMENIE Nederland Your notice of Your reference Date 08-02-2016 23-02-2016 Analysis Report 16.00634.08 Required tests : Identification number

More information

Tech Notes. TESTING PROTOCOL Fire Retardant Gel Coats. INTERPLASTIC CORPORATION Thermoset Resins Divison ISSUE 5

Tech Notes. TESTING PROTOCOL Fire Retardant Gel Coats. INTERPLASTIC CORPORATION Thermoset Resins Divison ISSUE 5 INTERPLASTIC CORPORATION Thermoset Resins Divison ISSUE 5 5 Tech Notes TESTING PROTOCOL Fire Retardant Gel Coats Issue Date: 4/22/2010 Document ID: TN-TS-05A 2010 Interplastic Corporation Testing Protocol

More information

TEST REPORT. Report No.: E Test Date: May 6, Rendered to: FUNDERMAX GMBH A-9300 St. Veit an der Glan, Austria

TEST REPORT. Report No.: E Test Date: May 6, Rendered to: FUNDERMAX GMBH A-9300 St. Veit an der Glan, Austria TEST REPORT Report No.: E6736.01-121-24 Test Date: May 6, 2015 Rendered to: FUNDERMAX GMBH A-9300 St. Veit an der Glan, Austria PRODUCT TYPE: Max Exterior F-Quality SERIES/MODEL: Décor. 0085 TEST METHOD:

More information

TEST REPORT. Report No.: D Rendered to: 3M COMPANY St. Paul, Minnesota

TEST REPORT. Report No.: D Rendered to: 3M COMPANY St. Paul, Minnesota Architectural Testing TEST REPORT Report No.: D7913.05-121-24 Rendered to: 3M COMPANY St. Paul, Minnesota PRODUCT TYPE: Window Film SERIES/MODEL: 3M Scotchshield Ultra 800 TEST METHOD: ASTM E 84-11a, Standard

More information

PERFORMANCE TEST REPORT. Rendered to: VELUX America, Inc. PRODUCT: SUN TUNNEL Acrylic Dome

PERFORMANCE TEST REPORT. Rendered to: VELUX America, Inc. PRODUCT: SUN TUNNEL Acrylic Dome PERFORMANCE TEST REPORT Rendered to: VELUX America, Inc. PRODUCT: SUN TUNNEL Acrylic Dome Report No: D3964.01-106-31 Report Date: 06/19/14 Test Record Retention Date: 06/03/18 130 Derry Court York, PA

More information

This document is a preview generated by EVS

This document is a preview generated by EVS INTERNATIONAL STANDARD ISO 14934-4 First edition 2014-08-15 Fire tests Calibration and use of heat flux meters Part 4: Guidance on the use of heat flux meters in fire tests Essais au feu Étalonnage et

More information

TECHNICAL BULLETIN Weston Parkway, Cary, North Carolina, Telephone (919) FLAMMABILITY TESTING: A REVIEW BY COTTON INCORPORATED

TECHNICAL BULLETIN Weston Parkway, Cary, North Carolina, Telephone (919) FLAMMABILITY TESTING: A REVIEW BY COTTON INCORPORATED TECHNICAL BULLETIN 6399 Weston Parkway, Cary, North Carolina, 27513 Telephone (919) 678-2220 TRI 4004 FLAMMABILITY TESTING: A REVIEW BY COTTON INCORPORATED 2004 Cotton Incorporated. All rights reserved;

More information

Australian Standard. Methods for fire tests on building materials, components and structures

Australian Standard. Methods for fire tests on building materials, components and structures AS 1530.3 1989 Australian Standard Methods for fire tests on building materials, components and structures Part 3: Simultaneous determination of ignitability, flame propagation, heat release and smoke

More information

RADIATION BLOCKAGE EFFECTS BY WATER CURTAIN

RADIATION BLOCKAGE EFFECTS BY WATER CURTAIN , Volume 6, Number 4, p.248-254, 04 RADIATION BLOCKAGE EFFECTS BY WATER CURTAIN C.L. Choi Department of Building Services Engineering, The Hong Kong Polytechnic University, Hong Kong, China ABSTRACT Water

More information

Performance Rating of Active Chilled Beams

Performance Rating of Active Chilled Beams AHRI Standard 1241 (SI) 2016 Standard for Performance Rating of Active Chilled Beams IMPORTANT SAFETY RECOMMENDATIONS AHRI does not set safety standards and does not certify or guarantee the safety of

More information

IMO Resolution MSC 61(67): Annex 1: Part 2

IMO Resolution MSC 61(67): Annex 1: Part 2 Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 (0 1925 655116 F : +44 (0) 1925 655419 E : warrington@exova.com W: www.exova.com IMO Resolution MSC 61(67): Annex 1: Part

More information

In Search of Standard Reference Materials (SRMs) for ASTM E05 Fire Standards by. Norman Alvares & Harry Hasegawa

In Search of Standard Reference Materials (SRMs) for ASTM E05 Fire Standards by. Norman Alvares & Harry Hasegawa In Search of Standard Reference Materials (SRMs) for ASTM E05 Fire Standards by Norman Alvares & Harry Hasegawa First Paragraph of E-691 Tests performed on presumably identical materials in presumably

More information

Flammability Test Results

Flammability Test Results Kmlex Aviation Inc. 265 Diab, Ville St-Laurent, Quebec, Canada, H4S 1E7 Tel: 514-626-1254, Fax: 514-784-131 Flammability Test Results FAR 25.853 / AWM 525.853 (a) Appendix F Part I, (a) 1, (i) 6 second

More information

Technical Training International Textiles Training September 2018 Ellen Roaldi Instructor

Technical Training International Textiles Training September 2018 Ellen Roaldi Instructor Technical Training International Textiles Training September 2018 Ellen Roaldi Instructor www.astm.org ASTM D1230 Flammability of Apparel Textiles Scope: This test method covers the evaluation of the flammability

More information

Reported Fires in High-Rise Structures in Selected Occupancies with and without Automatic Extinguishing Systems by Extent of Smoke Damage

Reported Fires in High-Rise Structures in Selected Occupancies with and without Automatic Extinguishing Systems by Extent of Smoke Damage Reported Fires in High-Rise Structures in Selected Occupancies with and without Automatic Extinguishing Systems by Extent of Smoke Damage Marty Ahrens Fire Analysis and Research Division National Fire

More information

August Process Industry Practices Electrical. PIP ELEHA01 Engineering Guide for Determining Electrical Area Classification

August Process Industry Practices Electrical. PIP ELEHA01 Engineering Guide for Determining Electrical Area Classification Electrical Engineering Guide for Determining Electrical Area Classification PURPOSE AND USE OF PROCESS INDUSTRY PRACTICES In an effort to minimize the cost of process industry facilities, this Practice

More information

ON FIRE OF QUALITY: SINCE 1972 A CONTINUUM

ON FIRE OF QUALITY: SINCE 1972 A CONTINUUM A CONTINUUM OF QUALITY: ON FIRE SINCE 1972 The Govmark Organization, Inc. Instrument Division (the largest USA manufacturer of fire and flammability test instrumentation worldwide) has been producing high

More information

Understanding total measurement uncertainty in power meters and detectors

Understanding total measurement uncertainty in power meters and detectors Understanding total measurement uncertainty in power meters and detectors Jay Jeong, MKS Instruments. Inc. INTRODUCTION It is important that users of calibrated power meters and detectors understand and

More information

REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045

REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045 REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045 FOR THE SCOPE OF ACCREDITATION UNDER NVLAP LAB CODE 100402-0. Project No. G101030158 Date: February 26, 2013 REPORT NO. 101030158CRT-001 TEST OF ONE LED

More information

Standard Laboratory Test Practice For Measurement Of Surface Appearance Change Of Textile Floor Covering As A Result Of The Vacuuming Process

Standard Laboratory Test Practice For Measurement Of Surface Appearance Change Of Textile Floor Covering As A Result Of The Vacuuming Process CRI TM 114-110901 Standard Laboratory Practice for Carpet Surface Appearance Change Due To Vacuuming P.O. Box 2048 Dalton Georgia 30722-2048 706.278.3176 carpet-rug.org Standard Laboratory Test Practice

More information

This document is a preview generated by EVS

This document is a preview generated by EVS INTERNATIONAL STANDARD ISO 11810 Second edition 2015-12-15 Lasers and laser-related equipment Test method and classification for the laser resistance of surgical drapes and/or patient protective covers

More information

Report VNLF Test Report

Report VNLF Test Report Report VNLF 081158.1 Test Report Applicant KLEEN-TEX Industries in Europa GmbH Münchner Straße 21 6330-Kufstein Austria Reference Mrs. Antje Schlegel Application Determination ofthe burning behaviour according

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SGS GOVMARK TESTING SERVICES, INC. 96 Allen Boulevard, Suite D Farmingdale, NY 11735 Doug Lipp Phone: 631 293 8944 THERMAL Valid To: May 31, 2018 Certificate

More information

REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045

REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045 REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045 FOR THE SCOPE OF. ACCREDITATION UNDER NVLAP LAB CODE 100402-0.. Project No. G101537614 Date: April 8, 2014 REPORT NO. G101537614CRT-005 TEST OF ONE LED

More information

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005 Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate D-PL-11035-03-00 according to DIN EN ISO/IEC 17025:2005 Period of validity: 25.10.2017 to 24.10.2022 Holder of certificate: DMT

More information

Intertek. REPORT NUMBER: SAT-005 ORIGINAL ISSUE DATE: October 29,2008 REVISED DATE: November 19, 2008

Intertek. REPORT NUMBER: SAT-005 ORIGINAL ISSUE DATE: October 29,2008 REVISED DATE: November 19, 2008 Intertek I 0:: o D.. W 0:: I en w I REPORT NUMBER: 3161466SAT-005 ORIGINAL ISSUE DATE: October 29,2008 REVISED DATE: EVALUATION CENTER Intertek Testing Services NA Inc. 16015 Shady Falls Rd. Elmendorf,

More information

Experimental Study to Evaluate Smoke Stratification and Layer Height in Highly Ventilated Compartments

Experimental Study to Evaluate Smoke Stratification and Layer Height in Highly Ventilated Compartments Experimental Study to Evaluate Smoke Stratification and Layer Height in Highly Ventilated Compartments Jason Huczek a, Marc Janssens a, Kentaro Onaka b, Stephen Turner c a SwRI, 6220 Culebra Road, San

More information

Test Practice for Efficacy Evaluation of Encapsulate Solutions

Test Practice for Efficacy Evaluation of Encapsulate Solutions CRI TEST METHOD 123 TECHNICAL BULLETIN Test Practice for Efficacy Evaluation of Encapsulate Solutions Table of Contents 1.0 Scope... 2 2.0 Referenced Documents... 2 3.0 Terminology... 2 4.0 Significance

More information

Fire Test Methods ASTM NFPA UL ISO IEC

Fire Test Methods ASTM NFPA UL ISO IEC Fire Test Methods ASTM NFPA UL ISO IEC D2859 (Standard Test Method for Ignition Characteristics of Finished Textile Floor Covering Materials) E84 (Standard Test Method for Surface Burning Characteristics

More information

Cone Calorimeter. (ISO 5660 ASTM E 1354) The most comprehensive bench scale fire test THE BENCHMARK IN FIRE TESTING

Cone Calorimeter. (ISO 5660 ASTM E 1354) The most comprehensive bench scale fire test THE BENCHMARK IN FIRE TESTING Cone Calorimeter (ISO 5660 ASTM E 1354) The most comprehensive bench scale fire test THE BENCHMARK IN FIRE TESTING Cone Calorimeter (ISO 5660 ASTM E 1354) The most comprehensive bench scale fire test The

More information

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630 FOR THE SCOPE OF ACCREDITATION UNDER A2LA TO ISO/IEC 17025:2005. REPORT 25800 COMMERCENTRE DRIVE, LAKE FOREST, CA 92630 Project No. G101786356 Date: August 19, 2014 REPORT NO. 101786356LAX-001 TEST OF

More information

TFI Report Reaction to fire test

TFI Report Reaction to fire test TFI Report 450740-07 Reaction to fire test For the classification according to EN 13501-1:2010 Customer GÜLSEVEN HALI GÜLSEVEN TEKSTIL KIMYA GIDA SAN. TIC. LTD. STI Ahi Evran Sanayi Sitesi Istiklal Caddesi

More information

Soot Mitigation Strategies

Soot Mitigation Strategies Soot Mitigation Strategies Walter P. Drosjack, P.E. David L. Oar, P.E., F.S.F.P.E. 32 nd Nuclear Air Cleaning Conference June 18-19, 2012 Who is URS? URS is one of the world s largest engineering, construction

More information

Australian/New Zealand Standard

Australian/New Zealand Standard AS/NZS 61779.6:2000 (Incorporating Amendment No. 1) AS/NZS 61779.6:2000 Australian/New Zealand Standard Electrical apparatus for the detection and measurement of flammable gases Part 6: Guide for the selection,

More information

IMO UNIFIED INTERPRETATIONS TO SOLAS CHAPTER II-2 AND RELATED FIRE TEST PROCEDURES

IMO UNIFIED INTERPRETATIONS TO SOLAS CHAPTER II-2 AND RELATED FIRE TEST PROCEDURES INTERNATIONAL MARITIME ORGANIZATION E IMO SUB-COMMITTEE ON FIRE PROTECTION 46th session Agenda item 5 FP 46/5 30 November 2001 Original: ENGLISH UNIFIED INTERPRETATIONS TO SOLAS CHAPTER II-2 AND RELATED

More information

PERFORMANCE TEST REPORT. Rendered to: Metal Building Manufacturers Association Cleveland, Ohio

PERFORMANCE TEST REPORT. Rendered to: Metal Building Manufacturers Association Cleveland, Ohio PERFORMANCE TEST REPORT Report No.: F6398.01-121-24 Test Date: March 9 th & 10th, 2016 Rendered to: Metal Building Manufacturers Association Cleveland, Ohio ASSEMBLIES: Metal Roof Panels and Clay Roof

More information

AS/NZS :2008

AS/NZS :2008 AS/NZS 60079.29.2:2008 Australian/New Zealand Standard Explosive atmospheres Part 29.2: Gas detectors Selection, installation, use and maintenance of detectors for flammable gases and oxygen AS/NZS 60079.29.2:2008

More information

Consultant Specification AGILE Wireless Fire Detection System

Consultant Specification AGILE Wireless Fire Detection System Contents Scope of Work... 2 The EN54 Part 2 & 4 Fire System... 2 Standards... 2 Wireless Intelligent Photoelectric Smoke Detector Specification... 4 Wireless Intelligent Thermal Heat Detector Specification...

More information

Ambient (ºF) Temperature Rise Above

Ambient (ºF) Temperature Rise Above Spec-00488 Heat CPH FX (763) Dissipation 422-2600 422-2211 in Electrical Enclosures Technical Thermal Management Information Heat Dissipation in Sealed Electrical Enclosures The accumulation of heat in

More information

We Identify and S.T.O.P. Your Noise Problems

We Identify and S.T.O.P. Your Noise Problems ASTM E-84 TESTING FOR MANUFACTURER, RENDERED TO: Acoustical Surfaces Inc. 123 Columbia Court North, Suite 201 Chaska, MN 55318 Noise S.T.O.P. Fabrisorb Acoustical Wall Panels TESTED: OCTOBER 3, 2002 October

More information

FLASHLIGHT ANSI STANDARDS

FLASHLIGHT ANSI STANDARDS FLASHLIGHT ANSI STANDARDS While Pelican was one of the first manufacturers to use quantifiable test procedures, the need was recognized to develop a common language that customers could use to select the

More information

RENDERED TO Vipco Industries Inc th Avenue SE Calgary, AB T2C 0B3

RENDERED TO Vipco Industries Inc th Avenue SE Calgary, AB T2C 0B3 REPORT NUMBER: 101207560COQ-001b ORIGINAL ISSUE DATE: June 12, 2013 TEST REPORT EVALUATION CENTER Intertek Testing Services NA Ltd. 1500 Brigantine Drive Coquitlam, B.C. V3K 7C1 RENDERED TO Vipco Industries

More information

TEST REPORT EVALUATION CENTER Intertek Testing Services NA Ltd Brigantine Drive Coquitlam, B.C. V3K 7C1

TEST REPORT EVALUATION CENTER Intertek Testing Services NA Ltd Brigantine Drive Coquitlam, B.C. V3K 7C1 REPORT NUMBER: 101145164COQ-005 ORIGINAL ISSUE DATE: April 25, 2013 TEST REPORT EVALUATION CENTER Intertek Testing Services NA Ltd. 1500 Brigantine Drive Coquitlam, B.C. V3K 7C1 RENDERED TO udecor Inc.

More information

Fire Scenario Influence of Material of Boundary Condition on Results

Fire Scenario Influence of Material of Boundary Condition on Results Fire Scenario Influence of Material of Boundary Condition on Results HUGHES ASSOCIATES EUROPE, srl FIRE SCIENCE & ENGINEERING Luciano Nigro Andrea Ferrari Elisabetta Filippo Hughes Associates Europe srl

More information

ASTM E84-99 ADHERED SURFACE BURNING CHARACTERISTICS

ASTM E84-99 ADHERED SURFACE BURNING CHARACTERISTICS ASTM E84-99 ADHERED SURFACE BURNING CHARACTERISTICS SPANK 9901101 REPORT NO. 75157 Septemer 11, 00 Prepared For: Pollack 150 Varick Street New York, NY 10013 F-316-A 555 76TH STREET S.W., GRAND RAPIDS.

More information

ISO 2685 INTERNATIONAL STANDARD. Aircraft Environmental test procedure for airborne equipment Resistance to fire in designated fire zones

ISO 2685 INTERNATIONAL STANDARD. Aircraft Environmental test procedure for airborne equipment Resistance to fire in designated fire zones INTERNATIONAL STANDARD ISO 2685 Second edition 1998-12-15 Aircraft Environmental test procedure for airborne equipment Resistance to fire in designated fire zones Aéronefs Méthode d'essai en environnement

More information

An experimental study of the impact of tunnel suppression on tunnel ventilation

An experimental study of the impact of tunnel suppression on tunnel ventilation An experimental study of the impact of tunnel suppression on tunnel ventilation Yoon J. Ko and George Hadjisophocleous Civil and Environmental Engineering, Carleton University 1125 Colonel By Drive, Ottawa,

More information

NF X : Parts 1, 2, 3, 4 & 5

NF X : Parts 1, 2, 3, 4 & 5 Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 (0 1925 655116 F : +44 (0) 1925 655419 E : warrington@exova.com W: www.exova.com NF X 10-702: Parts 1, 2, 3, 4 & 5 Fire test

More information

1.0 INTRODUCTION. Shaw Industries Group 2 SwRI Project No c

1.0 INTRODUCTION. Shaw Industries Group 2 SwRI Project No c 1.0 INTRODUCTION This report presents the results of a fire performance evaluation in accordance with the 2011 Edition of National Fire Protection Association (NFPA) Standard 265, Standard Methods of Fire

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 17065:2012 to provide product conformity certification Newport Business Park New Port Road Ellesmere Port CH65 4LZ United Kingdom Contact:

More information

Classification of Fire Performance of Wall and Ceiling Lining Materials

Classification of Fire Performance of Wall and Ceiling Lining Materials Classification of Fire Performance of Wall and Ceiling Lining Materials Using the Method of Kokkala, Thomas and Karlsson Reference: Kokkala, M.A. Thomas, P.H. and Karlsson, B. Rate of Heat Release and

More information

RENDERED TO. Laminam S.P.A. Via Ghiarola Nuova Fiorano Modenese Italy

RENDERED TO. Laminam S.P.A. Via Ghiarola Nuova Fiorano Modenese Italy REPORT NUMBER: 100900037COQ-002 ORIGINAL ISSUE DATE: October 10, 2012 TEST REPORT EVALUATION CENTER Intertek Testing Services NA Ltd. 1500 Brigantine Drive Coquitlam, BC V3K 7C1 RENDERED TO Laminam S.P.A.

More information

ISO/TR TECHNICAL REPORT. Reaction-to-fire tests Full-scale room tests for surface products Part 2: Technical background and guidance

ISO/TR TECHNICAL REPORT. Reaction-to-fire tests Full-scale room tests for surface products Part 2: Technical background and guidance TECHNICAL REPORT ISO/TR 9705-2 First edition 2001-05-01 Reaction-to-fire tests Full-scale room tests for surface products Part 2: Technical background and guidance Essais de réaction au feu Essais dans

More information

PRODUCT PERFORMANCE TEST REPORT. Report No.: D Test Date: May 29, Rendered to: Natural Light Energy Systems Phoenix, Arizona

PRODUCT PERFORMANCE TEST REPORT. Report No.: D Test Date: May 29, Rendered to: Natural Light Energy Systems Phoenix, Arizona Architectural Testing PRODUCT PERFORMANCE TEST REPORT Report No.: D7226.01-121-24 Test Date: May 29, 2014 Rendered to: Natural Light Energy Systems Phoenix, Arizona PRODUCT TYPE: Tubular Daylight Device

More information

RetardantsInc. The Decision You Make May Save A Life! 123 Columbia Court North Suite 201 Chaska, MN 55318

RetardantsInc. The Decision You Make May Save A Life! 123 Columbia Court North Suite 201 Chaska, MN 55318 EST. 1860 RetardantsInc. The Decision You Make May Save A Life! 123 Columbia Court North Suite 201 Chaska, MN 55318 952-448-7377 FAX:952-448-2613 Fire Retardant HOT LINE 1-800-913-9385 e-mail: info@fireretardantsinc.com

More information

DESIGNING A COMBUSTION AIR/GAS PRE MIX SYSTEM FOR RED RAY INFRARED PROCESS BURNERS

DESIGNING A COMBUSTION AIR/GAS PRE MIX SYSTEM FOR RED RAY INFRARED PROCESS BURNERS DESIGNING A COMBUSTION AIR/GAS PRE MIX SYSTEM FOR RED RAY INFRARED PROCESS BURNERS 1. Determine load requirements based on application () 2. Choose burner type based on process / application / requirements

More information

Standard Test Method for the Evaluation of Texture Appearance Retention of Carpets for Minimum Carpet Standards Program 1. Scope

Standard Test Method for the Evaluation of Texture Appearance Retention of Carpets for Minimum Carpet Standards Program 1. Scope Standard Test Method for the Evaluation of Texture Appearance Retention of Carpets for Minimum Carpet Standards Program 1. Scope 1.1 This practice describes the equipment and operation of the hexapod tumble

More information

Fire Curtains and Radiation Attenuation

Fire Curtains and Radiation Attenuation The National Construction Code (NCC) provides a Deemed-to-Satisfy (DtS) method for fire barriers. This method generally requires these barriers to provide a specific fire resistance level (FRL) based on

More information

The Decision You Make May Save A Life! 123 Columbia Court North Suite 201 Chaska, MN 55318

The Decision You Make May Save A Life! 123 Columbia Court North Suite 201 Chaska, MN 55318 Retardants Inc. The Decision You Make May Save A Life! 123 Columbia Court North Suite 21 Chaska, MN 55318 952-448-7377 FAX:952-448-2613 Fire Retardant HOT LINE 1-8-913-9385 e-mail: info@fireretardantsinc.com

More information

EAT 212 SOIL MECHANICS

EAT 212 SOIL MECHANICS EAT 212 SOIL MECHANICS Chapter 4: SHEAR STRENGTH OF SOIL PREPARED BY SHAMILAH ANUDAI@ANUAR CONTENT Shear failure in soil Drained and Undrained condition Mohr-coulomb failure Shear strength of saturated

More information

Test Report No. AJD Date: JUN.09, 2013 Page 1 of 6

Test Report No. AJD Date: JUN.09, 2013 Page 1 of 6 Test Report No. AJD201302471 Date: JUN.09, 2013 Page 1 of 6 WALER PRECISION MFG. SDN. BHD. NO.2, JALAN CANGGIH 1, TAMAN PERINDUSTRIAN CEMERALNG, 81800 ULU TIRAM, JOHOR, MALAYSIA. The following sample(s)

More information

SFI SPECIFICATION 17.1 EFFECTIVE: FEBRUARY 26, 2014 *

SFI SPECIFICATION 17.1 EFFECTIVE: FEBRUARY 26, 2014 * SFI SPECIFICATION 17.1 EFFECTIVE: FEBRUARY 26, 2014 * PRODUCT: On Board Fire Suppression Systems 1.0 GENERAL INFORMATION 1.1 This SFI Specification establishes uniform test procedures and minimum standards

More information

Test One: The Uncontrolled Compartment Fire

Test One: The Uncontrolled Compartment Fire The University of Edinburgh BRE Centre for Fire Safety Engineering One Day Symposium on The Dalmarnock Fire Tests: Experiments & Modelling Test One: The Uncontrolled Compartment Fire Cecilia Abecassis

More information

There are two devices used together for heating crude oil in petroleum refinery as in figure (1), and these devices are:

There are two devices used together for heating crude oil in petroleum refinery as in figure (1), and these devices are: Heating of Crude Oil 1.Introduction: There are two devices used together for heating crude oil in petroleum refinery as in figure (1), and these devices are: Heat Exchangers. Tube Still Heaters (Furnaces).

More information

New European Cable Testing and Classification

New European Cable Testing and Classification New European Cable Testing and Classification THE BENCHMARK IN FIRE TESTING New European Cable Testing and Classification Cables will be tested using 5 test methods, and classified by extending the provisions

More information

Structure Fires in Hotels and Motels

Structure Fires in Hotels and Motels Structure Fires in Hotels and Motels John Hall Fire Analysis and Research Division National Fire Protection Association October 2006 National Fire Protection Association, 1 Batterymarch Park, Quincy, MA

More information

L14 ENVIRONMENTAL CONTROL TECHNICAL DATA

L14 ENVIRONMENTAL CONTROL TECHNICAL DATA L14 ENVIRONMENTAL CONTROL Ever since components have been made to control electrotechnical tasks, heat loss has been a subject to take into consideration. Sometimes more sometimes less. Major problems

More information

Shipboard incinerators with capacities up to 4000 kw

Shipboard incinerators with capacities up to 4000 kw STANDARD FOR CERTIFICATION No. 2.9 Approval Programmes Type Approval Programmes for Marine Equipment Directive (MED) No. 431.90 - MED A.1/2.7 Shipboard incinerators with capacities up to 4000 kw JANUARY

More information

RetardantsInc. The Decision You Make May Save A Life! 123 Columbia Court North Suite 201 Chaska, MN 55318

RetardantsInc. The Decision You Make May Save A Life! 123 Columbia Court North Suite 201 Chaska, MN 55318 EST. 1860 RetardantsInc. The Decision You Make May Save A Life! 123 Columbia Court North Suite 201 Chaska, MN 55318 952-448-7377 FAX:952-448-2613 Fire Retardant HOT LINE 1-800-913-9385 e-mail: info@fireretardantsinc.com

More information

Review Fire Test Report

Review Fire Test Report Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 (0 1925 655116 F : +44 (0) 1925 655419 E : warrington@exova.com W: www.exova.com Review Fire Test Report Determination of

More information

SP METHOD 5320 Issue No: Test method for fire detection systems installed in engine compartments of heavy vehicles

SP METHOD 5320 Issue No: Test method for fire detection systems installed in engine compartments of heavy vehicles SP METHOD 5320 Test method for fire detection systems installed in engine compartments of heavy vehicles Page 1(17) Copyright This test method is copyrighted by SP. Neither a printed nor electronic copy

More information