2 The Remak team always endeavours to exceed the expectations of our customers in every aspect of our services. The second generation of our family company now undertakes this commitment. from the left: Vít Měrka, Jan Měrka, Jan Měrka jr.

3 Who We Are We are the largest manufacturer of high-quality air-handling devices with a tradition dating back to At our m 2 headquarters in Rožnov pod Radhoštěm, we give work to about 250 employees. Further dozens of employees take care of the production and commercial services of the REMAK brand at our commercial agencies in the Russian Federation. In total, including our twenty-five distributors in Europe and Asia, we export about 60 % of our products. 3 The Key to Success For us, the quality and reliability of our products, along with their comprehensiveness, are the keys to our success. The company is supported by a team of experts with many years of experience in the field of airhandling and ventilation. We are aware of the fact that customers buy our products as a part of the service we provide to them. Support and service The pre-sale support in designing air-handling devices is our strength and we enjoy it. We also place the same importance on after-sales support and services. Customer-specific solutions are always a positive challenge for us. Equipment Design We have developed AeroCAD, a unique design tool, enabling fast and error-free selection of air-handling units and the calculation of all aerodynamic and thermodynamic parameters. Participation in Exhibitions We regularly meet customers at major specialised international fairs, such as Aqua-Therm in Prague, Resta in Lithuania, SwissBau in Switzerland and Mir Klimata in Moscow. Guaranteed Parameters and Quality We have acquired the EUROVENT European certification and ISO 9001:2009 quality certificates. E Solution for a Better environment

4

5 What We Do Ventilation of industrial, commercial and civil buildings Ventilation of plants with specific requirements for Cleanability and microbial safety Resistance to specific corrosion effects ATEX (explosion-proof design) Seismic resistance Dehumidification of swimming-pool halls and technologies Cooling of plants with specific requirements 5 E Solution for a Better environment

6

7 CAKE Compact Heat Recovery Air-Handling Units Excellent access to internal assemblies Integrated plug&play switchboard The CAKE Series is a solution for installations in confined spaces (usually reconstructions and buildings with an expensive floor area). It has low requirements for maintenance staff experience. It can be installed in mild, subtropical and subpolar zones. With its features and parameters, it is predetermined to be used in commercial areas (e.g., areas for retail of goods and services, offices, shops and schools).thanks to the sophisticated control with an energy management system, which includes features such as night turn, night cooling, temperature start-up, start optimisation, automatic temperature and fan output correction, mixing according to external conditions, etc., CAKE units can provide as economical operation as possible. This compact unit complies with the Ecodesign requirements for the years 2016 and With its D1 mechanical stability, L1 casing air leakage, T2 thermal insulation and TB2 thermal bridging factor, our compact CAKE unit stands up well in a highly competitive environment and is among the best products on the market. Precision manufacturing of condensate drain pan Our compact unit is small, simple and cost-effective. We deliver catalogue as well as customised solutions, and this unit can be adapted to specific shape and dimension requirements. E Solution for a Better environment

8

9 AERO MASTER Cirrus Modular Air-Handling Units Waste-free production of panels High-strength self-contained panel AeroMaster Cirrus air-handling units enable you to execute specific applications complying with the highest requirements for environmental cleanliness with an air output of up to m 3 /h. An Ecodesign version is ready with an air output of up to m 3 /h. Lamel walls combined with self-contained panels (D1 mechanical strength and L1 casing air leakage) enable us to design environmentally-friendly air-handling units for waste-free and low energy consumption production. Applications AeroMaster Cirrus air-handling units are designed for installation on floors or substructures, and are delivered with a rigid base frame mounted in the factory. They can be used in normal environments (as per the applicable legislation) inside buildings as well as in outdoor conditions. Keeping energy in the mains ENERGY EFFICIENCY The biggest unit we have designed has a heating capacity of 1 MW XXX Report to performance data E Solution for a Better environment

10 Luzhniki Stadium Russia The Luzhniki Stadium in Moscow is the largest stadium in Russia. Since 2013, it has undergone reconstruction within which we delivered total of 209 pieces airhandling units consisting of AeroMaster Cirrus and and AeroMaster XP series with an unbelievable total air output of m 3 /h. During this reconstruction, the former athletics stadium will be converted into a solely football stadium with a capacity of spectators, ready for the opening of the 2018 World Football Championship.

11 AERO MASTER Cirrus Modular Air-Handling Units The Klíše swimming stadium Czech Republic Hriebienok Resort Slovakia United World College Dilijan Armenia We delivered air-handling equipment with a total air output of m 3 /h for the reconstruction of the Klíše city spa in Ústí nad Labem, starting with Vento units, through AeroMaster XP and AeroMaster Cirrus units up to AeroMaster FP overhead units and swimming-pool units, including the VCS control system. We delivered two AeroMaster XP and two AeroMaster Cirrus air-handling units and one Vento duct airhandling unit with a total air output of m 3 /h for the newly built Hriebienok Resort situated in Starý Smokovec, the heart of the Vysoké Tatry, equipped with an underground car park at a depth of 12 meters and with 330 parking bays. One of fifteen schools in the world and the first international boarding school in Armenia. This high school acquired a certificate for the application of environmentally-friendly solutions within the entire project life-cycle, and thus became the first certified green building in Armenia. For this school, we delivered five of our AeroMaster XP air-handling units, three Vento duct air-handling units and AeroMaster Cirrus air-handling units with a total air output of m 3 /h. 11 E Solution for a Better environment

12

13 AERO MASTER XP Modular Air-Handling Units Fans with effective EC motors EX version for explosive environments AeroMaster XP modular air-handling units are designed for easy to use air-handling and air-conditioning solutions intended for standard as well as clean area applications. They represent the highest quality class of air-handling units with an air output up to m 3 /h (Ecodesign version up to m 3 /h). The frameless casing, L1 air leakage class, mineral wool insulation of the casing with a density of 110 kg/m 3 and labyrinth connection of the AeroMaster XP casing panels enabled us to achieve high strength and acoustic attenuation. Applications AeroMaster XP air-handling units are intended for installation on the floor, and are delivered with a rigid base frame mounted in the factory. They are manufactured with the same design for indoor and outdoor environments. Integrated compressor units The total production of all air-handling units is nearly pcs, of which the most popular AeroMaster XP air-handling units make up 59 %. 13 E Solution for a Better environment

14 Country Park Moska Russia For the Country Park, a newly built modern office centre in Moscow with a total area of m 2, 21 floors, eleven elevators, a glass facade and congress hall for 700 people, we delivered 28 AeroMaster XP air-handling units and 10 Vento duct air-handling units, including a VCS control system, with a total air output of m 3 /h.

15 AERO MASTER XP Modular Air-Handling Units Centre of Physical and Technological Sciences Lithuania Hotel Sport Véska Czech Republic Eltham Hill School London United Kingdom For the newly built National Centre of Physical and Technological Sciences at Vilnius University with a total area of m 2, more than 260 labs, 350 offices and 16 work stations for students complying with the latest standards and serving as the largest physical, chemical and technological research base, we delivered specially designed air-handling equipment consisting of four AeroMaster Cirrus and eleven AeroMaster XP airhandling units with a total air output of m 3 /h. We equipped the Véska Multipurpose Resort, situated close to Oderské vrchy, with two AeroMaster XP and AeroMaster FP swimming-pool units and one AeroMaster XP unit, including a VCS control system, with a total air output of m 3 /h. We equipped this girls school with a tradition dating back to 1906 and situated in Eltham Hill on the southeastern outskirts of London with ventilation of school kitchen back areas using five of our AeroMaster XP units with a total air output of m 3 /h. 15 E Solution for a Better environment

16

17 AERO MASTER FP Flat Air-Handling Units Effective fans Highly effective counter-flow heat exchanger AeroMaster FP modular flat air-handling units are the ideal solution for ventilation and air-conditioning of administrative buildings, restaurants and other facilities with an air flow of up to m 3 /h (Ecodesign version up to m 3 /h). The unique frameless design of the casing, acoustic insulation of the casing (Dpr,w = 28 db) and labyrinth connection of the AeroMaster XP casing panels enabled us to achieve high strength and acoustic attenuation. Economy, Comfortable and Safe Operation Heat recovery Mixing (circulation) connection from below/side Fans with optional output control Automatic air output control Control by VCS units Integrated control of the electric heater (sequential or PWM) Simple change of the side configuration AeroMaster FP air-handling units are intended for suspended installation using threaded rods, providing an extremely low installation height of 360 mm thanks to insulation of the upper (25 mm) and side (40 mm) casing. 17 E Solution for a Better environment

18 Zlaté jablko commercial centre Czech Republic For the Zlaté jablko commercial and entertainment centre in Zlín with an area of m 2, including a six-hall multiplex cinema and 75 shops, and visitors in 2015, we delivered AeroMaster XP, AeroMaster FP and Vento air-handling units and DoorMaster door air curtains.

19 AERO MASTER FP Flat Air-Handling Units Patria Hotel Slovakia Wien Casino Rakousko City Polyclinic, Saint Petersburg Russia For the reconstruction of the wellness zone of the Patria Hotel, an exclusive dominant feature of Štrbské Pleso (1355 m above sea level) with beautiful views of the High Tatras, named after the nearby Patria peak, we delivered an AeroMaster FP air-handling unit. Reconstruction of the Casino in the Vienna centre also included our AeroMaster FP air-handling unit. For the City Polyclinic in the centre of Saint Petersburg, featuring advanced healthcare equipment and a wide range of specializations, including physiotherapy, cardiology, neurology, ophthalmology, urology and surgery, we delivered a complete air-handling system consisting of AeroMaster FP and AeroMaster XP units, with a total air output of m 3 /h. 19 E Solution for a Better environment

20

21 VENTO SYSTEM Duct Air Handling Units Explosion-proof fans Highly effective counter-flow heat exchanger Vento duct air-handling units have been developed by Remak since 1995 as a unique and complex system, which has been copied by many competitors and has thus become an industry standard. This system is intended for applications with an air output of up to m 3 /h. Outputs in compliance with Ecodesign 2016 and 2018 are dependent on customer specification, filter type, fan and heat exchanger. The modular concept enables maximum adaptation of the project solution to complicated space conditions in reconstructions and annex building sites. Individual components of this system can be placed into different air-handling assemblies or optionally interconnected by air ducts. Components Using a wide range of components and accessories, this system can be designed in accordance with the customer s specific needs: Fans Heat exchangers and heaters Coolers Filters Humidifiers Attenuators Dampers etc. Energy-efficient EC fans We are able to deliver ventilation assemblies from our stock in just a few days. 21 E Solution for a Better environment

22 Privilege Residential Complex in Saint Petersburg Russia This residential complex is situated on Krestovsky Island the most prestigious quarter of Saint Petersburg. This complex includes six buildings on the bank of the Něva River and offers a high level of comfort and the services of a five-star hotel bank, nursery school, spa, fitness centre, swimming pool, beauty salon, yacht marina and many others. For this complex, we delivered AeroMaster XP air-handling units and Vento duct air-handling units with a total air output of m 3 /h.

23 VENTO SYSTEM Duct Air Handling Units Izmirlian Medical Center Armenia Moscow Education Centre Russia Johann Gregor Mendel Station Antarctica For this newly reconstructed top-level hospital in the Armenian capital Yerevan, with 140 beds and 200 employees, specialising in urology, orthopaedics and sports traumatology and providing cost-effective services for the public, we delivered thirty Vento duct air-handling units with a total air output of m 3 /h. We delivered complete air-handling equipment, consisting of 34 Vento duct air-handling and 12 outdoor AeroMaster XP air-handling units with a total air output of m 3 /h for the reconstruction of this Moscow school focused on elementary and secondary education. For this scientific station in the Antarctica specialising in research into climatology, geology chemistry, botany and zoology and intended for fifteen researchers staying in the summer months, we delivered a Vento air-handling system, which had to be transported to the site by a navy icebreaker. 23 E Solution for a Better environment

24

25 DOOR MASTER C, D, P Air Curtains Directly driven fans Heaters with increased heating output DoorMaster C air curtains are air-handling devices which separate the indoor and outdoor environment using a visually non-disturbing air flow. They are designed for interior installation above entrance doors in all types of buildings with a max. door height of 2.5 m and for smaller facilities, such as small shops, hotels, restaurants, banks, post offices, petrol stations, etc. DoorMaster D air curtains are intended for administrative centres, hypermarkets, restaurants, garages, warehouses, etc. They are designed for internal installation above entrance doors with a max. height of 3.0 m. DoorMaster P air curtains are designed for indoor installations mounted above or beside door openings in industrial buildings where greater frequency of transport and handling devices or movement of persons can be expected. Typical installations include industrial halls or warehouses, reloading terminals, garages, car repair services, washing lines, drying houses, exhibition areas, market halls, supermarkets, shopping centres, etc. Low Output Tangential Fans Quiet running, excellent noise parameters Easy interconnection (curtain linking) Newly integrated auxiliary EC motors (C and D series) allow manual speed control and lower energy load so that they will comply with ERP 2016 and 2018 standards. 25 E Solution for a Better environment

26 IKEA Brno Czech Republic For the completion of the Ikea supermarket in Brno, which won the Ikea supermarket of the year 2014 award, we delivered our DoorMaster type D and P air curtains.

27 DOOR MASTER C, D, P Air Curtains OC Fachmarktzentrum Slovakia New World Financial Centre Poland Tula Shopping and Entertainment Centre Russia For this shopping centre in Bratislava, we delivered DoorMaster D and P air curtains and roof outlet fans. For the New World SA financial centre, specialising in leasing and administration of commercial buildings, we delivered an AeroMaster XP air-handling unit, including a VCB control system, and DoorMaster C and D air curtains. We resolved ventilation of the shopping and entertainment centre in Tula, Russia, situated 165 km from Moscow on the Upa River, using eight AeroMaster XP inlet and outlet air-handling units and three Vento duct air-handling units. To eliminate free air flow through the indoor and outdoor areas we installed DoorMaster D air curtains. 27 E Solution for a Better environment

28

29 fans BurgerKing Steffisburg Switzerland DHL Russia As the basic components of every Vento unit, fans are delivered in a wide range of versions with forward curved impellers (RE, RO types) and with backwards curved impellers (RP, RQ) for installation in duct systems, including sound insulated fans (RPH) as well as roof fans (RF). Duct fans for explosion hazardous areas (ATEX, Zone 1 RP EX, RQ Ex) are also available. All duct fans and single-phase fans are based on compact motorized impellers with an external rotor with low starting currents and very long service intervals and long service life of the bearings. Three-phase fans use the concept of a standard ISO motor and free rotating shaft impeller. Electric motors are equipped with integrated thermal protection. Output Control The output of all fans can be controlled over a wide range of speeds using optional independent regulators (TRN and PE voltage controllers, frequency inverters) or integrated electronic control of the EC fans and their controllers. Especially our RE fans with EC motors are suitable for controlled operation, providing excellent energy efficiency in full output operation as well as at lower speeds. Hotel Sorea Trigan Baník Slovakia Simplicity, durability, operational reliability, energy savings and flawless operation are the common features of the fans we offer. 29 E Solution for a Better environment

30

31 Control Units Yoshkar-Ola Pediatric Clinic Russia Parkhotel Richmond Česká republika VCS control units are compact control and power switchboards used for the decentralized regulation and control of AeroMaster, Cake and Vento air-handling units. They provide the equipment with high stability and safety while allowing easy control, including the viewing of operating states. Latest Features This control system is based on a Siemens controller and provides all the features requested by customers control of temperature, humidity and air quality, CO 2, CO and VCO content in the room, airflow and pressure control, adjustable time and temperature modes, free cooling, optional corrections to achieve room temperature, temperature dependent start-up, start optimisation, automatic temperature correction, fan output control, mixing according to external conditions or connection to the parent control system. Administrative building St. Petersburg Russia Remote Control using a Mobile Phone/Tablet The REMAK mobile application enables basic touch control and monitoring of VCS control units via a mobile device (phone or tablet) with Android OS. Our comprehensive electronic solution at a reasonable price for peace of mind. 31 E Solution for a Better environment

32

33 Clean Plants and Health Services Belfast Skin Clinic Ireland Göttlicher Heiland Hospital Austria Facilities with special demands for cleanliness are called hygienic or sometimes clean plants. Healthcare facilities and laboratories, semiconductor production and the pharmaceuticals industry are typical examples of hygienic plants. Hygienic plants require a wholesome and comfortable environment, and an air-handling system is the only tool enabling these objectives to be achieved. A wholesome and comfortable environment in hospitals helps to shorten stays of patients and aids more efficient and quality work by physicians and other medical personnel. This results in greater patient satisfaction as well as greater capacity of the healthcare facility. We have designed our hygiene units so that:: they will provably lower the contents of microorganisms and contaminants in the ventilated area thanks to the used filtration type; they will provide easy control of temperature and humidity; they will provide safe and repeated sanitation in the shortest possible time; they will minimize technological downtimes due to maintenance or repairs. University Hospital Brno Czech Republic We offer supervision over maintenance and installation of hygiene units, and thorough operating staff training. 33 E Solution for a Better environment

34

35 Swimming-Pool Halls Losiny Thermal spa Czech Republic Sport Hotel Dolní Morava Czech Republic Operating indoor swimming pools, aqua-parks and rehabilitation centres providing water treatment is very demanding, and inefficiency can cost the customer a lot of money. Therefore, our technology is based on customoriented approach, advanced technology and a unique management and control system which helps to monitor and significantly lower operating costs in such facilities. Our unit has been awarded a gold medal at the Aquatherm Fair for its quality workmanship (surface finish and uncompromising design of details in relation to the operational nature).. Remote administration for effective and immediate analysis of service events The Web Device Manager (WDEM) allows basic monitoring and operation control. Air flow visualisation, operating history, remote supervision and analytic support for users are the main advantages which provide users with the possibility to minimise operating and energy demands of our swimming-pool unit. 35 Mladá Boleslav City pool Czech Republic During the development of the 2nd generation of REMAK swimming-pool units, it was necessary to simulate extreme winter conditions, at temperatures down to -15 C, in our testing laboratory at an outlet air temperature of 30 C and humidity of 60 %. These conditions were maintained for a period of 3 months during the summer season when outside temperatures climbed above 30 C. E Solution for a Better environment

36

37 Air-Handling Units for Explosive Environments IRU Power Plant Estonsko 37 Secop Slovakia SSHR Czech Republic AeroMaster XP and Cirrus air-handling units meet the ATEX 100 Directive (European Parliament and Council Directive 2014/34/EC) and can be delivered in both outdoor and indoor versions. Each unit in the ATEX version will be designed and selected individually in accordance with the needs of the specific application. Classification of Air-Handling Units for Explosive Environments The unit meets ATEX 100 (European Parliament and Council Directive 2014/34/EC) FTZÚ Conformity Certificate Zone 1 Equipment group (area of application) Category 2 Gas explosive atmosphere G Explosive gas group IIB Heat class T4 Differences between ATEX and standard versions All the parts have a metal connection or contact to the central grounding point. The fan motors and impellers are type tested and certified in accordance with the ATEX Directive. Air filters are made of antistatic materials. Special bearings are used. Special grounding, conductive bridging and grommets are used. The units are manufactured with higher casing air leakage L2 in accordance with ČSN EN 1886/2008. Special chemical composition of internal aluminium assemblies. All the internal assemblies are certified by the Notified Bodies for the whole EU area A separate Conformity Certificate is issued for each unit. The units in the ATEX version are checked and tested for safety by the independent Notified Body 1026/ AO FTZÚ Ostrava Radvanice. Each piece of equipment must be labelled in accordance with the specific explosive area of application. E Solution for a Better environment

38

39 Seismic Areas For the newly built Yunus Emre power plant in Turkey, situated at an altitude of 500 m and with temperatures ranging from -20 C in winter to 42 C in summer, we have provided complete delivery of air-handling equipment with a total air output of m 3 /h. We have used 53 air-handling units and 67 condensing units in seismic versions, including measuring and control. The total weight of all the air-handling units is 86 tons. Some air-handling units are situated on the building s roof, 53 m high. This means that they had to be dimensioned for gravity acceleration of 20 g, while gravity acceleration at the ground level is only 0.2 g. Special requirements are applied for power station structures which must allow them to be safely shut down if an earthquake occurs. For nuclear power plants, it is necessary to ensure such conditions which will enable the reactor s active zone to be safely cooled. Design Requirements In seismic areas with a high risk of earthquakes, the basic aim is to design and build all structures and systems (including air-handling devices) so that damage to such structures and technology as well as casualties will be minimised as far as possible even if the maximum calculated seismic parameters have been reached. The REMAK team has the necessary know-how to ensure the seismic resistance of air-handling unit structures, thanks to which we are able to comply with these very specific requirements to ensure maximum satisfaction of the customer. 39 E Solution for a Better environment

40 Regional Sales We are active in many countries such as: Russia, Poland. Hungary, Armenia. Belgium, Estonia, Kazakhstan, Lithuania, Latvia, Moldavia, Mongolia, Netherlands, Austria, Romania, Slovakia, Slovenia, Switzerland, Ukraine, Uzbekistan, Great Britain, etc. The current list of distributor can be found at in the Contacts section. solution for a better environment 55R

Modular air-handling units

Modular air-handling units Modular air-handling units AHU N 12.10.002 Range AeroMaster XP Cirrus Modular air-handling units Why AeroMaster XP? The latest knowledge from field of projection, production and operation of air-handling

More information

AIR HANDLING UNITS MANDÍK

AIR HANDLING UNITS MANDÍK AIR HANDLING UNITS MANDÍK 2 CONTENTS MANDÍK, a. s. The Company... 3 Photo Gallery... 4 Unit Description... 6 Air handling unit parameters according to Eurovent... 7 Product Range of the Air Handling Units...

More information

Duct air-handling units

Duct air-handling units Why Vento? Duct units Vento are constructed to help to implement comprehensive but simple air handling devices at the same time. Only Vento offers You 10 advantages: Variability and compactness of products

More information

The power of ventilation

The power of ventilation The power of ventilation LindabAir Handling Unit Ensure the correct flow of fresh air, acceleration at the right rate and exact volume lindab.com 1 lindab air handling units Air Handling Units that maximise

More information

This document is a preview generated by EVS

This document is a preview generated by EVS TECHNICAL SPECIFICATION SPÉCIFICATION TECHNIQUE TECHNISCHE SPEZIFIKATION CEN/TS 16244 April 2018 ICS 91.040.10; 91.140.30 English Version Ventilation in hospitals - Coherent hierarchic structure and common

More information

COMBIFAB F Fan The flexible fan for dust extraction systems in all industries

COMBIFAB F Fan The flexible fan for dust extraction systems in all industries COMBIFAB F Fan The flexible fan for dust extraction systems in all industries Combifab F Fan Our Combifab F range of fans consists of four different fans solving all kinds of dust extraction applications

More information

Geniox. The next generation of air handling units

Geniox. The next generation of air handling units Fans Air Handling Units Air Distribution Products Fire Safety Air Conditioning Air Curtains and Heating Products Tunnel Fans Geniox The next generation of air handling units Reference: VIA University College,

More information

Smart air handling unit for swimming pools IN CONFORMITY WITH THE REQUIREMENTS OF

Smart air handling unit for swimming pools IN CONFORMITY WITH THE REQUIREMENTS OF Smart air handling unit for swimming pools IN CONFORMITY WITH THE REQUIREMENTS OF PERSONALIZED CORROSION-RESISTANT SAVING AmberAir Pool FOR A COMFORTABLE MICROCLIMATE AT A SWIMMING POOL AmberAir Pool units

More information

Requirements for the Collection, Transportation, Storage and Treatment of Cooling and Freezing Appliances containing Hydrocarbons (HC)

Requirements for the Collection, Transportation, Storage and Treatment of Cooling and Freezing Appliances containing Hydrocarbons (HC) Requirements for the Collection, Transportation, Storage and Treatment of Cooling and Freezing Appliances containing Hydrocarbons (HC) 1. Introduction 18 October 2006 The use of Chlorofluorocarbons (CFCs)

More information

Bathroom September 2010

Bathroom September 2010 International Market Strategy Topics Austria Egypt India Russia Slovakia World World BAUMAX Increased Its Profit LECICO Q2 Profit Hit by Warehouse Fire RAK CERAMICS Plans 2nd Plant ONNINEN Express Offices

More information

Competence Center in Electric Heating. February 2017

Competence Center in Electric Heating. February 2017 Competence Center in Electric Heating February 2017 Factsheet SST Group is the largest producer of electric heating cables and heat tracing solutions in Europe. Founded in 1991 1300 employees 4 own plants

More information

Fans Air Handling Units Air Distribution Products Fire Safety Air Conditioning Air Curtains and Heating Products Tunnel Fans. Geniox.

Fans Air Handling Units Air Distribution Products Fire Safety Air Conditioning Air Curtains and Heating Products Tunnel Fans. Geniox. Fans Air Handling Units Air Distribution Products Fire Safety Air Conditioning Air Curtains and Heating Products Tunnel Fans Geniox Quick guide Copyright: Systemair A/S, 1. edition 2017. We accept no liability

More information

Sýnishorn Ventilation in hospitals - Coherent hierarchic structure and common terms and definitions for a standard related to ventilation in hospitals

Sýnishorn Ventilation in hospitals - Coherent hierarchic structure and common terms and definitions for a standard related to ventilation in hospitals ÍSLENSKIR STAÐLAR CEN/TS 16244:2018 Gildistaka 15.5.2018 ICS: 91.04 Ventilation in hospitals - Coherent hierarchic structure and common terms and definitions for a standard related to ventilation in hospitals

More information

Keeping European Consumers safe Rapid Alert System for dangerous non-food products 2014

Keeping European Consumers safe Rapid Alert System for dangerous non-food products 2014 Keeping European Consumers safe Rapid Alert System for dangerous non-food products 2014 COMPLETE STATISTICS Justice and Consumers Directorate-General for Justice and Consumers Directorate Consumers Unit

More information

AQX Air handling units. Air flow 1, ,000 m 3 /h (350-44,400 l/s)

AQX Air handling units. Air flow 1, ,000 m 3 /h (350-44,400 l/s) AQX Air handling units Air flow 1,300-160,000 m 3 /h (350-44,400 l/s) Applications Commercial and Industrial New projects and renovation Suitable for new projects and renovations, Clivet AQX air handling

More information

TECHNICAL WHITE PAPER AUTOMATIC WARNING DEVICES FOR LIGHT LIQUID SEPARATORS

TECHNICAL WHITE PAPER AUTOMATIC WARNING DEVICES FOR LIGHT LIQUID SEPARATORS PROCESS AUTOMATION TECHNICAL WHITE PAPER AUTOMATIC WARNING DEVICES FOR LIGHT LIQUID SEPARATORS Recommendations for the Installation and Operation of Light Liquid Separators This White Paper presents European

More information

Product Brochure Low-profile air handling units ATpicco. Modular configuration with highly efficient energy recovery

Product Brochure Low-profile air handling units ATpicco. Modular configuration with highly efficient energy recovery Product Brochure Low-profile air handling units ATpicco Modular configuration with highly efficient energy recovery Economy and ecology in focus The signs of the times are unmistakable Investors, plant

More information

air handling units AT THE LEADING EDGE OF AIR FLOW

air handling units AT THE LEADING EDGE OF AIR FLOW air handling units floway AT THE LEADING EDGE OF AIR FLOW floway: Delivering Advanced Air Flow and Full Satisfaction Energy recovery was at the heart of CIAT new Floway offering. The range proposes compact

More information

AIR CONDITIONING UNIT WITH AN INTEGRATED HEAT PUMP

AIR CONDITIONING UNIT WITH AN INTEGRATED HEAT PUMP AIR CONDITIONING UNIT WITH AN INTEGRATED HEAT PUMP 2 AIR CONDITIONING UNIT WITH AN INTEGRATED HEAT PUMP Description of the Unit: The air conditioning unit with an integrated reversible heat pump is a variant

More information

ErP 2009/125/CE. Directives Eco design Energy labelling

ErP 2009/125/CE. Directives Eco design Energy labelling ErP 2009/125/CE Directives Eco design Energy labelling ErP Policy ims The ErP (Energy related Products) European policy is split into two directives: ecodesign and energy labelling. It aims to improve

More information

CATALOGUE 03/2013. Air-handling units

CATALOGUE 03/2013. Air-handling units CATALOGUE 03/2013 Air-handling units CONTENTS Main features...2 Construction...4 Outputs and functions...6 Output of heaters... 7 Output of coolers... 7 Heat exchangers... 7 Choce of equipment and composition

More information

COMMERCIAL LINE DUPLEX ROTO

COMMERCIAL LINE DUPLEX ROTO EN COMMERCIAL LINE DUPLEX ROTO 2016 2018 All-purpose units are used for comfort ventilation, as well as hot air heating and cooling offices, shops, retail, school buildings, restaurants, etc. The units

More information

LOWERING THE COST OF HIGH CEILINGS

LOWERING THE COST OF HIGH CEILINGS LOWERING THE COST OF HIGH CEILINGS in partnership with The Carbon Trust recommends destratification as an effective energy-saving strategy.* WHY CHOOSE ZOO FANS? Fast Payback ZOO Fans create even temperatures

More information

Flexomix A versatile range of modular air handling units

Flexomix A versatile range of modular air handling units Flexomix A versatile range of modular air handling units We've been saving the Earth's resources for over forty years Copenhagen Airport, Harpa Concert Hall in Reykjavik, sports arena's, schools, offices,

More information

SWIMMING POOL AIR MANAGEMENT DanX

SWIMMING POOL AIR MANAGEMENT DanX SWIMMING POOL AIR MANAGEMENT DanX SWIMMING POOL AIR MANAGEMENT Comfortable swimming in every climate It is impossible to avoid water evaporation in swimming pool halls, however using a carefully designed

More information

EUROPE STARTS WITH YOU!

EUROPE STARTS WITH YOU! EUROPE STARTS HERE! EUROPE STARTS WITH YOU! The European Heritage Label is a valuable opportunity for an heritage site, offering increased prestige and visibility. WHAT IS THE EUROPEAN HERITAGE LABEL?

More information

This document is a preview generated by EVS

This document is a preview generated by EVS TECHNICAL SPECIFICATION SPÉCIFICATION TECHNIQUE TECHNISCHE SPEZIFIKATION CEN/TS 16677 May 2014 ICS 11.040.70 English Version Ophthalmic optics - Reference method for the testing of spectacle frames and

More information

Heating with pellets kw

Heating with pellets kw YOUR RELIABLE PARTNER Heating with pellets Present years on the market 110 for over 10-60 kw Competence is our success HERZ FACTS: 35 companies Group headquarters in Austria Research & development in Austria

More information

English Version. This Technical Report was approved by CEN on 11 December It has been drawn up by the Technical Committee CEN/TC 135.

English Version. This Technical Report was approved by CEN on 11 December It has been drawn up by the Technical Committee CEN/TC 135. TECHNICAL REPORT RAPPORT TECHNIQUE TECHNISCHER BERICHT CEN/TR 17052 January 2017 ICS 91.080.10 English Version Guidelines on implementing EN 1090-1:2009+A1:2011, Execution of steel structures and aluminium

More information

acr chiller rent GmbH the profitable alternative. Rental products from acr the fast and reliable solution for your company.

acr chiller rent GmbH the profitable alternative.   Rental products from acr the fast and reliable solution for your company. Rental products from acr the fast and reliable solution for your company. Rental products Refrigeration / Air-conditioning Heating Power supply Accessories Specialty plants Used equipment market acr chiller

More information

ETA ACCU 90% HIGHEST EFFICIENCY AIR HANDLING UNIT

ETA ACCU 90% HIGHEST EFFICIENCY AIR HANDLING UNIT 90% EFFICIENCY HIGHEST EFFICIENCY AIR HANDLING UNIT Packaged energy recovery solutions for Green Buildings Integrated Accumulator, controls and DX Cooling System CLEAN AIR SINCE 1963 Euroclima is a company

More information

Log fired heating system

Log fired heating system Log fired heating system De Luxe 18 De Luxe 20-40 Lambda 20-40 Competence is our success... HERZ FACTS: 22 companies Group headquarters in Austria Research & development in Austria Austrian owned 2,400

More information

WORLDWIDE VENTILATION SOLUTIONS

WORLDWIDE VENTILATION SOLUTIONS WORLDWIDE VENTILATION SOLUTIONS UK MADE NUAIRE. FOR THE COMPLETE VENTILATION SOLUTION WORLDWIDE VENTILATION SOLUTIONS NUAIRE IS A BRITISH COMPANY WITH A LONG HISTORY OF INNOVATION in the field of ventilation

More information

Contents. EN :2012 (E) Issue 5 ( ) Page

Contents. EN :2012 (E) Issue 5 ( ) Page Contents Page Foreword... 4 1 Scope... 6 2 Normative references... 6 3 Terms and definitions... 7 4 Symbols and abbreviations... 7 5 Determination of inspection and testing requirements... 8 5.1 General...

More information

Power packs TectoRack. Energy-saving and ecological CO2 power packs

Power packs TectoRack. Energy-saving and ecological CO2 power packs Power packs TectoRack Energy-saving and ecological CO2 power packs TectoRack 2/3 The energy-efficient power pack for medium and low temperature refrigeration applications Using full refrigeration capacity

More information

A new way of fighting the fire!

A new way of fighting the fire! A new way of fighting the fire! Elide Fire Extinguishing Ball: Thailand Aeroics Aviations introduces Elide Fire Extinguishing Ball in the capacity of an Authorized Distributor of the product for Maharashtra

More information

Compact. Efficient. TROX.

Compact. Efficient. TROX. Compact. Efficient. TROX. The art of handling air TROX understands the art of handling air like no other company. Since its foundation in 1951, TROX has been developing and manufacturing sophisticated

More information

RUSSIAN MANUFACTURER OF FIREFIGHTING EQUIPMENT AND FOAM CONCENTRATES DEVELOPER OF DESIGN SOLUTIONS FOR FOAM FIRE EXTINGUISHING SYSTEMS

RUSSIAN MANUFACTURER OF FIREFIGHTING EQUIPMENT AND FOAM CONCENTRATES DEVELOPER OF DESIGN SOLUTIONS FOR FOAM FIRE EXTINGUISHING SYSTEMS RUSSIAN MANUFACTURER OF FIREFIGHTING EQUIPMENT AND FOAM CONCENTRATES DEVELOPER OF DESIGN SOLUTIONS FOR FOAM FIRE EXTINGUISHING SYSTEMS Pozhneftekhim LLC +7 (812) 309 91 09 TMC Pozhneftekhim LLC +7 (499)

More information

SWIMMING POOL SWIMMING POOL DEHUMIDIFICATION

SWIMMING POOL SWIMMING POOL DEHUMIDIFICATION SWIMMING POOL DEHUMIDIFICATION SWIMMING POOL Dehumidification systems for private indoor swimming pools, Dehumidification for swimming pools, hotels, spas or therapeutic clinics spas and therapeutic clinics

More information

new HYGIENE AND COMFORT FOR HOSPITALS AND PUBLIC BUILDINGS HYGIENIC AIR HANDLING UNITS HYGIENIC AHU N o : Range: AmberAir

new HYGIENE AND COMFORT FOR HOSPITALS AND PUBLIC BUILDINGS HYGIENIC AIR HANDLING UNITS   HYGIENIC AHU N o : Range: AmberAir new HYGIENIC AIR HANDLING UNITS WWW.SALDA.LT AHU N o : 16.11.005 Range: AmberAir HYGIENIC HYGIENE AND COMFORT FOR HOSPITALS AND PUBLIC BUILDINGS HYGIENE AND COMFORT FOR HOSPITALS AND PUBLIC BUILDINGS The

More information

PTG, SWT Series. Heat Recovery Systems

PTG, SWT Series. Heat Recovery Systems PTG, SWT Series Heat Recovery Systems Hot air exhaust in summer Shutter Ducting system Available hot air Fresh air inlet Compressor Because of the enclosed, compact construction of screw compressors, it

More information

Metal Woodprint The natural look

Metal Woodprint The natural look Metal Woodprint The natural look The Metal Woodprint range combines the benefits of Luxalon Metal Ceilings with the ambience of natural wood. Our Linear ceiling systems are now available in a range of

More information

TCF Termoventilatori Condizionatori Felsinea S.r.l.

TCF Termoventilatori Condizionatori Felsinea S.r.l. TCF Termoventilatori Condizionatori Felsinea S.r.l. TCF THE HISTORY TCF Srl was founded in 1977 and is based on the Cadriano di Granarolo Emilia industrial estate to the north of Bologna. The production

More information

ÍST EN :2015. Gildistaka ICS: 53.06

ÍST EN :2015. Gildistaka ICS: 53.06 ÍST EN 1459-3:2015 Gildistaka 15.11.2015 ICS: 53.06 Rough-terrain trucks - Safety requirements and verification - Part 3: Additional requirements for variable reach trucks fitted with elevating work platform

More information

For more information on Tarkett go to

For more information on Tarkett go to Granit SD Toro SC STATIC CONTROL HOMOGENEOUS FLOORINGS VINYL iq Granit SD for static dissipation (10 6 R 10 8 Ω) iq Toro SC for static conductivity (5x10 4 R 10 6 Ω) Unique conductive iq PUR iq Unique

More information

CZECH LUMINAIRE MANUFACTURER

CZECH LUMINAIRE MANUFACTURER CZECH LUMINAIRE MANUFACTURER ALPHALIGHTING CZ Ltd. 5-year quarantee of availability of spare parts LED luminaire brand ALPHALIGHTING has been an integral part of the largest domestic and foreign industrial

More information

Pillow Plate Heat Exchanger SYNOTHERM

Pillow Plate Heat Exchanger SYNOTHERM Pillow Plate Heat Exchanger SYNOTHERM Functional principle of Pillow Plate Heat Exchangers SYNOTHERM 8000 heat transfer coeffcient h [ W/m 2 k ] 7000 6000 5000 4000 3000 2000 1000 0 Pillow Plate Heat Exchanger

More information

Irish Standard I.S. EN :2009

Irish Standard I.S. EN :2009 Irish Standard NSAI 2009 No copying without NSAI permission except as permitted by copyright law. Incorporating amendments/corrigenda issued since publication: This document is based on: This document

More information

COMMERCIAL LINE. DUPLEX Flexi

COMMERCIAL LINE. DUPLEX Flexi EN COMMERCIAL LINE DUPLEX Flexi 2016 2018 ATREA HISTORY ATREA was started as a private company in 1990 in the Czech Republic. Very shortly it began to focus on the production of ventilation units with

More information

Overview and Decision Guidance. Buildings & Locking Systems

Overview and Decision Guidance. Buildings & Locking Systems Overview and Decision Guidance Buildings & Locking Systems High-level security The EVVA security pyramid Which locking system is the right one for your requirements? Choosing a master key system presents

More information

The national standards bodies of:

The national standards bodies of: EN 1317 for Vehicle Restraint Systems (VRS) - overview presented by B. Wolfgang Wink Senior Manager International Division Volkmann & Rossbach Germany 16th World Meeting International Road Federation Lisboa

More information

Energy efficient ventilation equipment

Energy efficient ventilation equipment Energy efficient ventilation equipment Komfovent Energy Efficient KOMFOVENT is a trademark for ventilation products produced by the company AMALVA. KOMFOVENT stands for comfort, healthy indoor climate,

More information

This document is a preview generated by EVS

This document is a preview generated by EVS TECHNICAL REPORT RAPPORT TECHNIQUE TECHNISCHER BERICHT CEN/TR 16829 August 2016 ICS 13.220.40; 13.230; 53.040.10 English Version Fire and explosion prevention and protection for bucket elevators Prévention

More information

Medical gloves for single use - Part 2: Requirements and testing for physical properties

Medical gloves for single use - Part 2: Requirements and testing for physical properties Irish Standard I.S. EN 455-2:2015 Medical gloves for single use - Part 2: Requirements and testing for physical properties CEN 2015 No copying without NSAI permission except as permitted by copyright law.

More information

Air Handling Units. Geniox. Quick guide

Air Handling Units. Geniox. Quick guide Air Handling Units Geniox Quick guide Copyright: Systemair A/S, 2. edition 2018. We accept no liability for printing errors or alterations of products. The dimensions and data used in this leaflet are

More information

Sýnishorn Chemical disinfectants and antiseptics - Application of European standards for chemical disinfectants and antiseptics

Sýnishorn Chemical disinfectants and antiseptics - Application of European standards for chemical disinfectants and antiseptics ÍST EN 14885:2015 Gildistaka 15.12.2015 ICS: 71.1 Chemical disinfectants and antiseptics - Application of European standards for chemical disinfectants and antiseptics Staðfestur af Staðlaráði Íslands

More information

A new way of fighting the fire!

A new way of fighting the fire! A new way of fighting the fire! ElideFireExtinguishingBall:Thailand Elide Fire is a ball shaped fire extinguisher. Simply thrown into a fire, it will activate within 3-10 seconds and effectively disperse-extinguishing

More information

REFRIGERATING SYSTEMS AND HEAT

REFRIGERATING SYSTEMS AND HEAT IRISH STANDARD I.S. EN 378-2:2008 ICS 27.200 27.080 National Standards Authority of Ireland Glasnevin, Dublin 9 Ireland Tel: +353 1 807 3800 Fax: +353 1 807 3838 http://www.nsai.ie REFRIGERATING SYSTEMS

More information

COMPANY PROFILE.

COMPANY PROFILE. COMPANY PROFILE www.jeremias-group.com JEREMIAS GROUP 8 Production sites 83,000 References worldwide 1,200 Employees 60 Countries 2 A STRONG, OPEN AND INTERNATIONAL GROUP WELCOME TO JEREMIAS GROUP Jeremias

More information

Metal Woodprint The natural look

Metal Woodprint The natural look Metal Woodprint The natural look The Metal Woodprint range combines the benefits of Luxalon Metal Ceilings with the ambience of natural wood. Our Linear ceiling systems are now available in a range of

More information

Dual certification! Air handling units for potentially explosive atmospheres

Dual certification! Air handling units for potentially explosive atmospheres Dual certification! Air handling units for potentially explosive atmospheres X-CUBE Ex A certified safety product The air handling unit with dual ATEX certification ATEX directive 2014/34/EU applies to

More information

ISO INTERNATIONAL STANDARD. Acoustics Measurement of sound pressure level from service equipment in buildings Engineering method

ISO INTERNATIONAL STANDARD. Acoustics Measurement of sound pressure level from service equipment in buildings Engineering method INTERNATIONAL STANDARD ISO 16032 First edition 2004-09-15 Acoustics Measurement of sound pressure level from service equipment in buildings Engineering method Acoustique Mesurage du niveau de pression

More information

COOLSTREAM S T A R PRODUCT OVERVIEW COOLSTREAM S T A R

COOLSTREAM S T A R PRODUCT OVERVIEW COOLSTREAM S T A R PRODUCT OVERVIEW COOLSTREAM S T A R COOLSTREAM S T A R : CoolStream is an evaporative cooling, ventilation and air conditioning system. Its operating modes range from pure summer cooling through to all

More information

Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Tunnel Fans. Facilitator Healthcare

Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Tunnel Fans. Facilitator Healthcare Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Tunnel Fans Facilitator Healthcare Systemair - Ventilation World Wide Systemair is a leading ventilation

More information

security WHAT MAKES US DIFFERENT? We Place A Huge Importance On Integrity.

security WHAT MAKES US DIFFERENT? We Place A Huge Importance On Integrity. 2 firetech.com.mt 3 That sense of security WE BELIEVE THAT PEACE OF MIND IS PRICELESS WHAT MAKES US DIFFERENT? Firetech provide reliable fire, safety and security solutions that protect people, property,

More information

Air handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation

Air handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation Air handling units KLASIK Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation KLASIK air handling units Customer oriented and unique

More information

ILNAS-EN ISO 23640:2015

ILNAS-EN ISO 23640:2015 In vitro diagnostic medical devices - Evaluation of stability of in vitro diagnostic reagents (ISO 23640:2011) In-vitro-Diagnostika - Haltbarkeitsprüfung von Reagenzien für invitro-diagnostische Untersuchungen

More information

BUSINESS PLAN CEN/TC 197 PUMPS EXECUTIVE SUMMARY

BUSINESS PLAN CEN/TC 197 PUMPS EXECUTIVE SUMMARY Page: 1 BUSINESS PLAN CEN/TC 197 PUMPS EXECUTIVE SUMMARY Pumps are widely used in industry and facilities applications at a worldwide level. European pumps production represents a prime part of of the

More information

CIRCULAIRE LAMINAR AIR FLOW

CIRCULAIRE LAMINAR AIR FLOW CIRCULAIRE LAMINAR AIR FLOW Including Visionaire Touchscreen British Design & Manufacture THE MARKET LEADER IN CLEAN AIR SOLUTIONS +44(0)1278 458090 How Does Laminar Flow Work? LAMINAR FLOW AIR FILTRATION

More information

Danfoss the world s biggest producer of radiator thermostats

Danfoss the world s biggest producer of radiator thermostats Danfoss the world s biggest producer of radiator thermostats The world s first radiator thermostat was produced by Danfoss in 1943. Danfoss biggest and best for radiator thermostats The idea was both simple

More information

Sýnishorn Health care services - Quality management systems - Requirements based on EN ISO 9001:2015

Sýnishorn Health care services - Quality management systems - Requirements based on EN ISO 9001:2015 ÍST EN 15224:2016 Gildistaka 15.3.2017 ICS: 3.12 Health care services - Quality management systems - Requirements based on EN ISO 9001:2015 Staðfestur af Staðlaráði Íslands Staðlaráð Íslands - Eftirprentun

More information

Operation of electrical installations -- Part 1: General requirements

Operation of electrical installations -- Part 1: General requirements Irish Standard I.S. EN 50110-1:2013 Operation of electrical installations -- Part 1: General requirements CENELEC 2013 No copying without NSAI permission except as permitted by copyright law. I.S. xxx:

More information

ELSTA MOSDORFER- Energy Distribution with Competence

ELSTA MOSDORFER- Energy Distribution with Competence PRODUCT RANGE ELSTA MOSDORFER- Energy Distribution with Competence Quality and Standards We are your reliable partner for electrical energy distribution, industrial control and automation engineering.

More information

Sýnishorn Fire resistance test for service installations - Part 1: Ventilation ducts

Sýnishorn Fire resistance test for service installations - Part 1: Ventilation ducts ÍST EN 1366-1:2014 Gildistaka 1.2.2015 ICS: 13.22 Eldþolsprófanir fyrir þjónustustöðvar - Hluti 1: Loftræstistokkar Fire resistance test for service installations - Part 1: Ventilation ducts Staðfestur

More information

MKN Galley Solutions

MKN Galley Solutions MKN Galley Solutions MKN Master of Performance MKN is at home in the best professional kitchens in the world, whether in high class hotels and restaurants, in community catering, in catering chains, in

More information

Leading manufacturer of high-end ball valves and pneumatic actuators. Over 60 years experience with industrial applications

Leading manufacturer of high-end ball valves and pneumatic actuators. Over 60 years experience with industrial applications Company profile Leading manufacturer of high-end ball valves and pneumatic actuators Over 60 years experience with industrial applications We develop, manufacture and market our products HABONIM tailor-made

More information

KORABASE. new! Heat exchangers 04/18

KORABASE. new! Heat exchangers 04/18 Heat exchangers new! 04/18 MORE THAN YEARS QUALITY COMPLEXITY INNOVATION DESIGN To have a reliable partner for solving with both large and small projects in the area of heating is not a question of price.

More information

Discover ebm-papst in commercial kitchen equipment. Durable and reliable products for constant use.

Discover ebm-papst in commercial kitchen equipment. Durable and reliable products for constant use. Discover ebm-papst in commercial kitchen equipment. Durable and reliable products for constant use. About ebm-papst. As a leader in technologies for ventilation and drive engineering, ebm-papst is in demand

More information

MARINE APPLICATIONS MARINE» PRODUCTS AND SOLUTIONS FOR MARINE APPLICATIONS

MARINE APPLICATIONS MARINE» PRODUCTS AND SOLUTIONS FOR MARINE APPLICATIONS MARINE APPLICATIONS MARINE» PRODUCTS AND SOLUTIONS FOR MARINE APPLICATIONS MEETING THE HIGHEST DEMANDS - EFFICIENT HVAC SOLUTIONS FOR ARCTICAL TO TROPICAL CONDITIONS AT FLÄKTGROUP WE WANT TO EXCEED the

More information

AHU N Range AQX. AQX Air handling units. Air flow 1, ,000 m3/h (350-44,400 l/s)

AHU N Range AQX. AQX Air handling units. Air flow 1, ,000 m3/h (350-44,400 l/s) AHU N 13.05.001 Range AQX AQX Air handling units Air flow 1,300-160,000 m3/h (350-44,400 l/s) Applications Commercial and Industrial New projects and renovation Suitable for new projects and renovations,

More information

Camping tents (ISO 5912:2011)

Camping tents (ISO 5912:2011) Irish Standard I.S. EN ISO 5912:2011 Camping tents (ISO 5912:2011) NSAI 2011 No copying without NSAI permission except as permitted by copyright law. I.S. xxx: Irish Standard national specification based

More information

Detect. React. Benefit. Increase the availability of your plants with SIMATIC Notifier!

Detect. React. Benefit. Increase the availability of your plants with SIMATIC Notifier! Detect. React. Benefit. Increase the availability of your plants with! Unrestricted Siemens AG 2019 siemens.com/simatic-notifier New milestones of productivity with SIMATIC Notifier Page 2 Detect React

More information

(INDUSTRIAL) KITCHEN VENTILATION MODERN (INDUSTRIAL) KITCHEN VENTILATION SYSTEMS REFERENCES

(INDUSTRIAL) KITCHEN VENTILATION MODERN (INDUSTRIAL) KITCHEN VENTILATION SYSTEMS REFERENCES (INDUSTRIAL) KITCHEN VENTILATION MODERN (INDUSTRIAL) KITCHEN VENTILATION SYSTEMS REFERENCES MODERN SOLUTIONS FOR (INDUSTRIAL) KITCHENS SKV and TPV ventilation and air-conditioning ceilings are the flagships

More information

PACKAGING - REQUIREMENTS FOR PACKAGING RECOVERABLE BY MATERIAL RECYCLING STANDARD I.S. EN 13430:2004. Price Code

PACKAGING - REQUIREMENTS FOR PACKAGING RECOVERABLE BY MATERIAL RECYCLING STANDARD I.S. EN 13430:2004. Price Code STANDARD I.S. EN 13430:2004 ICS 13.030.50 55.020 National Standards Authority of Ireland Dublin 9 Ireland PACKAGING - REQUIREMENTS FOR Tel: (01) 807 3800 Fax: (01) 807 3838 PACKAGING RECOVERABLE BY MATERIAL

More information

Bathroom July Topics

Bathroom July Topics International Market Strategy Topics Bulgaria Bulgaria Germany Germany India Romania Serbia Slovakia Slovenia United Kingdom IDEAL STANDARD Cutting Further Jobs Ceramic Production To Be Cut HANSGROHE Sets

More information

COMMERCIAL LINE. DUPLEX MultiEco

COMMERCIAL LINE. DUPLEX MultiEco EN COMMERCIAL LINE DUPLEX MultiEco 2016 2018 DUPLEX MultiEco Compact ventilation units in the DUPLEX line are used for comfortable ventilation, hot-air heating and cooling for small offices, stores, retail

More information

Clean Air Laminar Flow Ceiling CG 3 A CLEAN AIR WORLD. Draft-free, comfortable room climate. Minimal, undisruptive noise level

Clean Air Laminar Flow Ceiling CG 3 A CLEAN AIR WORLD. Draft-free, comfortable room climate. Minimal, undisruptive noise level Clean Air Laminar Flow Ceiling CG 3 Ultra Clean Ventilation System with Unidirectional Flow Draft-free, comfortable room climate Minimal, undisruptive noise level Easy to disinfect housing design with

More information

People ignore design that ignores people. Frank Chimero

People ignore design that ignores people. Frank Chimero People ignore design that ignores people. Frank Chimero AN EFFECTIVE & WELL-DESIGNED OFFICE IS NOT JUST ABOUT WALLS & FURNITURE 3 AN EFFECTIVE & WELL-DESIGNED OFFICE IS YOUR PARTNER IN EVERYDAY BUSINESS

More information

This document is a preview generated by EVS

This document is a preview generated by EVS TECHNICAL SPECIFICATION SPÉCIFICATION TECHNIQUE TECHNISCHE SPEZIFIKATION CEN/TS 16165 April 2012 ICS 17.040.20; 93.080.10 English Version Determination of slip resistance of pedestrian surfaces - Methods

More information

COMPACT VENTILATION UNITS DUPLEX R5

COMPACT VENTILATION UNITS DUPLEX R5 EN COMPACT VENTILATION UNITS DUPLEX R5 2016 2018 A COMPANY HISTORY ATREA PRODUCTS ATREA was founded in 1990 in Jablonec nad Nisou in the Czech Republic as a purely family company. Even today, it still

More information

FINAL REPORT ON THE 4 TH JOINT CROSS-BORDER EMC MARKET SURVEILLANCE CAMPAIGN (2011) LED LIGHTING PRODUCTS

FINAL REPORT ON THE 4 TH JOINT CROSS-BORDER EMC MARKET SURVEILLANCE CAMPAIGN (2011) LED LIGHTING PRODUCTS FINAL REPORT ON THE 4 TH JOINT CROSS-BORDER EMC MARKET SURVEILLANCE CAMPAIGN (2011) LED LIGHTING PRODUCTS 1 CONTENTS S/N ITEM PAGE A. EXECUTIVE SUMMARY 3 B. ELEMENTS OF THE CAMPAIGN 5 1. Reasons for the

More information

SMART WAY TO HANDLE THE AIR

SMART WAY TO HANDLE THE AIR SMART WAY TO HANDLE THE AIR WWW.SALDA.LT Rotor - heat pump RR coil Rotor Counter-flow Cross-flow top CLASS MODEL BOX 1 GEMSTONE IN AHU MARKET! SALDA UAB devoted 27 years to investigation, production, qualification

More information

The Power of the Market Energy procurement by METRO Group in international markets - Requirements for the Polish energy market

The Power of the Market Energy procurement by METRO Group in international markets - Requirements for the Polish energy market The Power of the Market Energy procurement by METRO Group in international markets - Requirements for the Polish energy market Warsaw, 30 September 2009 Olaf Schulze Member of the Management Board MEM

More information

Air Handling Units. Real HVACR people who understand your needs.

Air Handling Units. Real HVACR people who understand your needs. Air Handling Units Real HVACR people who understand your needs. Copyright HC Heat-Exchangers (PTY) Ltd. 1 Copyright HC Heat-Exchangers (PTY) Ltd. 2 About the HC AHU range HC Heat-Exchangers rich engineering

More information

This document is a preview generated by EVS

This document is a preview generated by EVS TECHNICAL REPORT RAPPORT TECHNIQUE TECHNISCHER BERICHT CEN/TR 16798-18 June 2017 ICS 91.120.10; 91.140.30 English Version Energy performance of buildings - Ventilation for buildings - Part 18: Interpretation

More information

Modulair vilten plafondsy. Modular felt Ceiling system

Modulair vilten plafondsy. Modular felt Ceiling system Modulair vilten plafondsy Modular felt Ceiling system The Modulair Ceiling vilten that plafondsy had to be made Design as a source of inspiration Felt making has been a popular method of creating textiles

More information

Güntner Info. finoox technology. fin and tube heat exchangers. Tailor-made solutions!

Güntner Info. finoox technology. fin and tube heat exchangers. Tailor-made solutions! Güntner Info finoox technology fin and tube heat exchangers Tailor-made solutions! Heat exchangers Knowledge-based engineering Special Air Conditioning and Refrigeration applications and the cooling of

More information

KOMFORT EC DB Suspended heat recovery air handling units

KOMFORT EC DB Suspended heat recovery air handling units 2018 AIR HANDLING UNITS KOMFORT EC DB Suspended heat recovery air handling units Features Air handling units for efficient supply and exhaust ventilation in flats, houses, cottages and other buildings.

More information

Pillow Plate Heat Exchanger SYNOTHERM

Pillow Plate Heat Exchanger SYNOTHERM Pillow Plate Heat Exchanger SYNOTHERM Functional principle of Pillow Plate Heat Exchangers SYNOTHERM 8000 heat transfer coeicient h [ W/m 2 k ] 6000 4000 2000 0 Pillow Plate Heat Exchanger Tubular Heat

More information

ITC PROFESSIONAL SERVICES

ITC PROFESSIONAL SERVICES ITC PROFESSIONAL SERVICES high support of quality and safety November 2016 INSTITUT PRO TESTOVÁNÍ A CERTIFIKACI, a. s. Institute for Testing and Certification, Inc. (hereinafter only ITC) is a private