TRV 300 RADIATOR VALVES

Size: px
Start display at page:

Download "TRV 300 RADIATOR VALVES"

Transcription

1 RADIATOR VALVES THERMOSTATIC HEADS Placed on radiator valves, these self-acting thermostatic heads for adjusting temperature are reliable, accurate, and long-lasting. LIQUID FILLED SENSOR ELEMENT For higher closing power, reduced maintenance costs and trouble-free operation. REMOTE SENSOR OPTION For total accuracy. TEMPERATURE LIMITATION Set maximum and minimum temperatures, helping to reduce running costs.

2 TECHNICAL DESCRIPTION Application: Heating systems Functions: Regulating Shut-off Maximum and minimum restriction Nominal temperature range: See each product Temperature: Max. ambient temperature: 50 C Min. ambient temperature: -25 C Stroke: 0.22 mm/k Heat transfer from inlet water: Thermostatic head with integral sensor and thermostatic head with remote setting: 0.4K Thermostatic head with remote sensor: 0.3K Replacement thermostatic head M28x1,5: 0.8K Time to close: Thermostatic head with integral sensor 24 min Thermostatic head with remote sensor: Horizontally fitted sensor 12 min Vertically fitted sensor 15 min Hysteresis: 0.2K Materials: Plastic parts of ABS, acetal and nylon. Sensor element contains ethyl acetate liquid. Colour: White Marking: Thermostats are marked with TA and, where applicable, with the CEN symbol. 2

3 C With locking ring C With two locking screws Allen key 2 mm C Protective model C 3

4 THERMOSTATIC HEAD WITH REMOTE SENSOR Capillary tube length C 1,25 m C 2 m C 5 m C 8 m With locking ring Capillary tube length C 2 m With two locking screws Allen key 2 mm Capillary tube length C 2 m To install the capillary tube in electric installation tube. Note: Tube without bends; use minimum 25 mm diameter. Tube with bends; use minimum 32 mm diameter. THERMOSTATIC HEAD WITH REMOTE SETTING Capillary tube length C 2 m C 5 m C 8 m 4

5 THERMOSTATIC HEAD WITH REMOTE SETTING AND REMOTE SENSOR Capillary tube length C 2 m x 1,5 m To install the capillary tube in electric installation tube. Note: Tube without bends; use minimum 25 mm diameter. Tube with bends; use minimum 32 mm diameter. THERMOSTATIC HEAD WITH REMOTE SENSOR FOR POCKET TUBE OR HEAT TRANSFER CRADLE Pocket tube and heat transfer cradle - see Accessories. Capillary tube length C 2 m C 2 m REPLACEMENT THERMOSTATIC HEAD M28 Ø C M28 HANDWHEEL

6 ACCESSORIES Setting key For thermostatic head, protective model Locking ring For thermostatic head with integral/remote sensor Key regulator 4 mm allen key Adapter M28-M Restriction pin For thermostatic head with intergral/remote sensor

7 Pocket tube for remote sensor For thermostatic head / G1/2 Heat transfer cradle for remote sensor For thermostatic head / FUNCTION TRV 300 When the ambient temperature rises above the set value of the thermostat, the fluid in the sensor expands and starts to close the valve. When the ambient temperature falls below the thermostat s set value, the fluid in the sensor contracts and the return spring in the valve starts to open the valve. When set to the frost protection position ( ), the valve opens at a temperature of about 6 C in order to prevent the heating system from freezing. NB: If the TRV 300 with integral sensor is fitted vertically to a valve, with the sensor upwards, it may be affected by the heat from the pipe below and therefore close too early. In such cases, a thermostatic unit with a remote sensor should be used, with the sensor placed immediately beneath the radiator if possible or, if not, in the centre of the room. The scale on the thermostat represents a temperature change of 4 C between each numeral. Each mark on the scale represents a 1 C change. Thermostatic head with remote sensor for pocket tube or heat transfer cradle When the water temperature rises above the thermostat s set value, the thermostat start to close the valve. When the water temperature falls below the set value, the return spring in the valve start to open the valve. 7

8 MAXIMUM TEMPERATURE RESTRICTION Set the index opposite to the maximum room temperature required. E.g. number 3 corresponding to 20 C room temperature. 1. Put the restriction pin in a little way opposite to number 5 to mark the correct pin position. Close the thermostat a little by turning it clockwise. 2. Fully insert the restriction pin. 3. Open the thermostat by turning it anti-clockwise and check that the index stops at a position corresponding to desired room temperature. NOMINAL TEMPERATURE RANGE The specified temperatures apply at the nominal lift height in accordance with CEN. Under normal operating conditions, the set temperature will be maintained with a maximum deviation of ±1K. SETTING SCALES The closing temperature is normally 2K higher than ambient temperature. Thermostatic head with integral sensor / remote sensor The various settings give approximately the following room temperatures: Thermostatic head, protective model The various settings give approximately the following room temperatures: Thermostatic head with remote setting / remote setting and remote sensor The various settings give approximately the following room temperatures: Thermostatic head with remote sensor for pocket tube or heat transfer cradle The settings produce approximately the water temperatures shown on the thermostatic head. Tour & Andersson retains the right to make changes to its products and specifications without prior notice TRV

THERMOSTATIC EXPANSION VALVES AND THERMOSTAT CONTROL DEVICES

THERMOSTATIC EXPANSION VALVES AND THERMOSTAT CONTROL DEVICES FUNCTION Thermostatic expansion valves are used to regulate and cut-off the flow of the heat transfer fluid that circulates inside airconditioning system terminals (radiators, fan coils, etc.). Thermostat

More information

THERMOSTATIC EXPANSION VALVES AND THERMOSTAT CONTROL DEVICES

THERMOSTATIC EXPANSION VALVES AND THERMOSTAT CONTROL DEVICES FUNCTION Thermostatic expansion valves are used to regulate and cut-off the flow of the heat transfer fluid that circulates inside airconditioning system terminals (radiators, fan coils, etc.). Thermostat

More information

4-way valve with thermostatic option with variable centre distance and pre-adjustment for Single pipe and Dual pipe systems.

4-way valve with thermostatic option with variable centre distance and pre-adjustment for Single pipe and Dual pipe systems. 4-way valve with thermostatic option with variable centre distance and pre-adjustment for Single pipe and Dual pipe systems. CT3101.0_00 EN June 2016 o o o o Valve with pre-adjustment; Variable centre

More information

Thermostatic head B. Thermostatic heads Secured model designed for public buildings

Thermostatic head B. Thermostatic heads Secured model designed for public buildings Thermostatic head B Thermostatic heads Secured model designed for public buildings IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Thermostatic head B Thermostatic head B The thermostatic head B

More information

Thermostatic head K. with contact or immersion sensor. Thermostat-Köpfe For medium temperature control

Thermostatic head K. with contact or immersion sensor. Thermostat-Köpfe For medium temperature control Thermostatic head K with contact or immersion sensor Thermostat-Köpfe For medium temperature control IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Thermostatic head K with contact or immersion

More information

Thermostatic head K. Thermostatic heads with built-in sensor and remote sensor

Thermostatic head K. Thermostatic heads with built-in sensor and remote sensor Thermostatic head K Thermostatic heads with built-in sensor and remote sensor IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Thermostatic head K Thermostatic head K The thermostatic heads K are

More information

THERMOSTATIC SINGLE-PIPE AND DOUBLE-PIPE VALVES

THERMOSTATIC SINGLE-PIPE AND DOUBLE-PIPE VALVES ST.07.05.00 THERMOSTIC SINGLE-PIPE AND DOUBLE-PIPE VALVES 1. Art.1420 THERMOSTIC SINGLE-PIPE VALVE Single-pipe valves allow manual, thermostatic or thermo-electric regulation. Separation of the lockshield

More information

Halo. Thermostatic heads with built-in sensor

Halo. Thermostatic heads with built-in sensor Halo Thermostatic heads with built-in sensor IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Halo Halo The thermostatic head Halo is used to control the temperature of individual rooms using, for

More information

Calypso TRV-3. (for the Nordic countries) Thermostatic radiator valves With presetting

Calypso TRV-3. (for the Nordic countries) Thermostatic radiator valves With presetting Calypso TRV-3 (for the Nordic countries) Thermostatic radiator valves With presetting IMI TA / Thermostatic heads and Radiator valves / Calypso TRV-3 (for the Nordic countries) Calypso TRV-3 (for the Nordic

More information

FLOWRETT, TA-UNI. Thermostatic valves with radiator connection system One-pipe

FLOWRETT, TA-UNI. Thermostatic valves with radiator connection system One-pipe FLOWRETT, TA-UNI Thermostatic valves with radiator connection system One-pipe IMI TA / Thermostatic heads and Radiator valves / FLOWRETT, TA-UNI FLOWRETT, TA-UNI Compatible with most radiators on the market,

More information

THERMOSTATIC RADIATOR VALVES FOR IRON, COPPER, POLYETHYLENE AND MULTILAYER PIPE PRODUCTION RANGE IRON PIPE CODE CONNECTION

THERMOSTATIC RADIATOR VALVES FOR IRON, COPPER, POLYETHYLENE AND MULTILAYER PIPE PRODUCTION RANGE IRON PIPE CODE CONNECTION THERMOSTATIC RADIATOR VALVES FOR IRON, COPPER, POLYETHYLENE AND MULTILAYER PIPE CT0031.0_10 EN August 2016 THERMOSTATIC RADIATOR VALVES * * * * 028 * LICENSED USE OF TRADEMARK NR. 43 PRODUCTION RANGE IRON

More information

The new Terrier Belmont Thermostatic Radiator Valve range

The new Terrier Belmont Thermostatic Radiator Valve range The new Terrier elmont Thermostatic Radiator Valve range Manual Radiator Valves The new manual radiator valve range offering both traditional handwheel and lockshield styles, along with a new concealed

More information

Thermostatic Actuators

Thermostatic Actuators 2 111 EN 215-1 RTN51.. with remote sensor RTN81 with remote adjuster ACVATIX TM Thermostatic Actuators for radiator valves VDN.., VEN.., VUN.., VPD.. and VPE.. RTN51.. RTN81 Self-acting, without auxiliary

More information

Straight pattern thermostatic radiator valve vertical or horizontal mounting with (368T CPDLS) matching drain off lockshield

Straight pattern thermostatic radiator valve vertical or horizontal mounting with (368T CPDLS) matching drain off lockshield Straight pattern thermostatic radiator valve vertical or horizontal mounting with (368T CPDLS) matching drain off lockshield Straight pattern TRV & drain off lockshield pack Size Pattern No. Pack 1 Qty

More information

Radiator Valve Program

Radiator Valve Program Radiator Valve Program Heat seeks cold faster when the temperature difference is greater. Lowering the temperature of a room reduces the amount of heat leaving the room (heat loss). Installing thermostats

More information

RA2000 Thermostatic Radiator Valves

RA2000 Thermostatic Radiator Valves Data Sheet RA2000 Thermostatic Radiator Valves Application regulate the flow of hot water or steam through free-standing radiators, baseboards or convectors in hot water and two-pipe low pressure steam

More information

TA-MATIC

TA-MATIC TA-MATIC 3400 11-5-15 Thermostatic mixing valve for domestic hot water 2007.06 Technical description Application: Domestic hot water systems Function: The TA-MATIC 3400 is intended mainly as a central

More information

Data sheet Thermostatic sensors type RA 2000

Data sheet Thermostatic sensors type RA 2000 Data sheet Thermostatic sensors type RA 2000 EN 215-1 RA 2990 RA 2992 RA 2920 RA 5060 RA 5074 Application The RA series is a comprehensive programme of radiator thermostats which covers all central and

More information

Type 5347 (TR/STL), Type 5348 (TR/ST) and Type 5349 (STM/STL) Double Thermostats

Type 5347 (TR/STL), Type 5348 (TR/ST) and Type 5349 (STM/STL) Double Thermostats Thermostats Type 343 Safety Temperature Monitor (STM) Type 344 Temperature Regulator (TR) Type 34 Safety Temperature Limiter (STL) Type 347 (TR/STL), Type 348 (TR/ST) and Type 349 (STM/STL) Double Thermostats

More information

Form 4: Integrated Science Notes TOPIC: TEMPERATURE CONTROL AND VENTILATION TEMPERATURE CONTROL: HEAT TRANSFER

Form 4: Integrated Science Notes TOPIC: TEMPERATURE CONTROL AND VENTILATION TEMPERATURE CONTROL: HEAT TRANSFER Form 4: Integrated Science Notes TOPIC: TEMPERATURE CONTROL AND VENTILATION TEMPERATURE CONTROL: HEAT TRANSFER Heat energy can be transferred from a place where it is very hot to a place where it is not

More information

We have replacements! Introducing the NEW Macon Controls EVO, VAO/VAC and EVO-Z

We have replacements! Introducing the NEW Macon Controls EVO, VAO/VAC and EVO-Z We have replacements! Introducing the NEW Macon Controls EVO, VAO/VAC and EVO-Z Contact us today to find out more about these new Macon products! P: 413-594-8695 F: 413-598-8109 www.tunstall-inc.com New

More information

TS RD 7761 RD, 7761 RD

TS RD 7761 RD, 7761 RD 1/2 HERZ Calis TS RD three way valve HERZ Calis TS RD 100% three-way valve for heating and cooling Datasheet for 1 7761 RD, Issue 0716 Dimensions in mm Order number Dimension R A B C kvs dp (bar) maximum

More information

Section - A. Radiator Valves

Section - A. Radiator Valves Section - Radiator Valves RDITOR VLVES EXMPLE OF PPLICTION 2 6 9 3 5 7 1 4 8 2 1 Thermostat adaptable valves. 2 Lockshield valves. 3 4-way thermostat adaptable valves for one-pipe and two-pipe systems.

More information

Radiator Connection System, Thermostatic Valve and Return Valve with Shutoff Function

Radiator Connection System, Thermostatic Valve and Return Valve with Shutoff Function HERZ-3000 Radiator Connection System, Thermostatic Valve and Return Valve with Shutoff Function Standard Sheet for 3791 3792 Edition 1000 (0999) Dimensions in mm 1 3001 01 Cone sleeve 1 3002 01 Connection

More information

Heating Controls Thermostatic and Manual Radiator Valve range

Heating Controls Thermostatic and Manual Radiator Valve range Heating ontrols Thermostatic and Manual Radiator Valve range Heating ontrols New thermostatic and manual radiator valves with built-in energy saving solutions With increasing demands on specifiers and

More information

Aquastrom T plus Thermostatic valve with adjustable temperature control range and fixed residual volume flow for circulation pipes

Aquastrom T plus Thermostatic valve with adjustable temperature control range and fixed residual volume flow for circulation pipes Thermostatic valve with adjustable temperature control range Technical information Tender specification: Oventrop thermostatic valve Aquastrom T plus with presetting for circulation pipes. Thermal control

More information

ВОДЯНЫЕ И МАСЛЯНЫЕ БАНИ

ВОДЯНЫЕ И МАСЛЯНЫЕ БАНИ ВОДЯНЫЕ И МАСЛЯНЫЕ БАНИ PRECISION AND SAFETY BROUGHT TO THE POINT. WATERBATH W OILBATH O 00% ATMOSAFE. MADE IN GERMANY. Uniquely precise and reliable. Of course always at the right temperature Since in

More information

Heating Technology sinc e

Heating Technology sinc e Catalogue Heating Technology sinc e A THERMOSTATIC B VALVES C ZONE D E REGULATION F FLOW G COMPONENTS H COMPONENTS I PRODUCTS HEADS, ACTUATORS FOR VALVES AND MANIFOLDS, VALVES AND LOCKSHIELDS FOR RADIATORS

More information

caleffi hydronic valves page 1 of 12

caleffi hydronic valves page 1 of 12 caleffi hydronic valves page 1 of 12 page 2 of 12 MANUAL RADIATOR VALVES 1601811 - Series 340 1601812 - Series 341 1603748 - Seies 411 1603749 - Series 412 CONVERTIBLE RADIATOR VALVES 1601816 - Series

More information

RT021 User and Installation Instructions

RT021 User and Installation Instructions RT021 User and Installation Instructions Battery Operated Electronic Room Thermostat with TPI Temperature Control Software 1 2 The RT021 is a battery powered electronic room thermostat designed to provide

More information

SOLUTIONS GUIDE. For total efficiency

SOLUTIONS GUIDE. For total efficiency 2014-2015 SOLUTIONS GUIDE For total efficiency THERMOSTATIC RADIATOR HEADS Comap Thermostatic heads have been counted amongst the best sellers in Europe for decades, thanks to their high manufacturing

More information

IMI Heimeier Kit Hydroca ble

IMI Heimeier Kit Hydroca ble IMI Heimeier Kit Hydroca ble Thermostatic valves with radiator connection systems Thermostatic valve and lockshield with tube-bend for the installation as angle form or axial form with press- or sliding

More information

INSTALLATION AND MAINTENANCE MANUAL. Alcor FA

INSTALLATION AND MAINTENANCE MANUAL. Alcor FA INSTALLATION AND MAINTENANCE MANUAL IST 03 F 048-01 Alcor FA Aluminium electric radiators with heat transfer fluid EN Dear customer, Thank you for choosing our product. Read this manual carefully before

More information

ST Wiring diagram. Product description. Standard temperature controller. Order number

ST Wiring diagram. Product description. Standard temperature controller. Order number ST64-31.10 Standard temperature controller Order number 900197.007 Old Id.Nr.: 386169 Wiring diagram Product description The controller ST64-31.10 was developed for simple thermostatic controls. The round

More information

Thermostatic heads. For all thermostatic valve bodies and radiators with integrated valves

Thermostatic heads. For all thermostatic valve bodies and radiators with integrated valves Thermostatic heads For all thermostatic valve bodies and radiators with integrated valves Pressurisation & Water Quality Balancing & Control Thermostatic Control ENGINEERING ADVANTAGE ThermostatIC HEADS

More information

Thermostatic head with wax sensor

Thermostatic head with wax sensor Combined with valves covered by EN215 01 november 2004 ı Technical communication n da Use In modern society research concerning comfort in the home becomes a factor of prime importance. In order to obtain

More information

Convertible radiator valve for one-pipe systems, centre distance 35 mm

Convertible radiator valve for one-pipe systems, centre distance 35 mm Convertible radiator valve for one-pipe systems, centre distance 35 mm 56 series ACCREDITED ISO 900 FM 65 033/6 GB Function 56 series convertible radiator valves are used on one-pipe radiator systems.

More information

TRV & Lockshield Pack Angle Pattern Thermostatic Radiator Valve Vertical or horizontal mounting with (367 CPLS) matching lockshield

TRV & Lockshield Pack Angle Pattern Thermostatic Radiator Valve Vertical or horizontal mounting with (367 CPLS) matching lockshield TRV & Lockshield Pack Angle Pattern Thermostatic Radiator Valve Vertical or horizontal mounting with (367 CPLS) matching lockshield GENERAL INFORMATION Size Pattern No. Pack 1 Qty Code Barcode Angle Pattern

More information

teide termo plus+ HEATING SERIES SCOPE THERMOSTATIC VALVES SERVICE CONDITIONS COMPONENTS TECHNICAL SHEET 07/2017 IP20060 PAG. 1/9

teide termo plus+ HEATING SERIES SCOPE THERMOSTATIC VALVES SERVICE CONDITIONS COMPONENTS TECHNICAL SHEET 07/2017 IP20060 PAG. 1/9 HEATING SERIES QUALITY BY TRADITION teide termo plus+ TECHNICAL SHEET 07/2017 IP20060 SCOPE The thermostatic valves and heads from TEIDE TERMO PLUS series can be used in individual or collective heating

More information

Installation and operating instructions

Installation and operating instructions Installation and operating instructions To be precise. Installation and operating instructions Table of contents General notes Page Thermostatic valve 3 Faults Causes Remedial action 4 Temperature setting

More information

Frost Protection Thermostat

Frost Protection Thermostat 1 203 Frost Protection Thermostat Electromechanical thermal reset limit thermostat RAK-TW.5..H RAK-TW.5..H.. Use Monitoring of frost protection temperature, with single-pole changeover microswitch Switching

More information

TRV pack Eclipse. Thermostatic valves with radiator connection systems Thermostatic raditor valve with automatic flow control, head and lockshield

TRV pack Eclipse. Thermostatic valves with radiator connection systems Thermostatic raditor valve with automatic flow control, head and lockshield TRV pack Eclipse Thermostatic valves with radiator connection systems Thermostatic raditor valve with automatic flow control, head and lockshield IMI HEIMEIER / Thermostatic heads and Radiator valves /

More information

STRAIGHT AND ANGLED THERMOSTATIC VALVES

STRAIGHT AND ANGLED THERMOSTATIC VALVES ST.07.01.00 STRIGHT ND NGLED THERMOSTTIC VLVES 1. DESCRIPTION FR thermostatic valves are preset for assembly of thermostatic and thermo-electric actuators, which control opening and closure. rt. 16 Chrome-plated

More information

DEVIATING VALVES ART K063

DEVIATING VALVES ART K063 FUNCTION The flow diverter valve Art.307 makes it possible to supply a branch circuit. Prepared to receive our electro-thermal controls Art. 978, 979, 980 or our thermostatic heads with remote sensor Art.

More information

T4398A,B Precision Electric Heating Thermostat

T4398A,B Precision Electric Heating Thermostat T398A,B Precision Electric Heating Thermostat FEATURES PRODUCT DATA APPLICATION The T398 Electric Heating Thermostat provides precise, accurate line voltage control of electric heating equipment. A snap

More information

INSTALLATION AND MAINTENANCE MANUAL BLITZ FD_

INSTALLATION AND MAINTENANCE MANUAL BLITZ FD_ INSTALLATION AND MAINTENANCE MANUAL IST 03 F 017-01 BLITZ FD_ Aluminium electric radiators with heat transfer fluid GB Dear customer, Thank you for choosing our product. Read this manual carefully before

More information

Thermostatic heads. for all thermostatic valve bodies and radiators with integrated valves. To be precise.

Thermostatic heads. for all thermostatic valve bodies and radiators with integrated valves. To be precise. Thermostatic heads for all thermostatic valve bodies and radiators with integrated valves To be precise. Thermostatic heads Table of contents Page Thermostatic heads Construction Application 4 Function

More information

The heart of electric appliances ELECTRIC WATER HEATING MADE IN ITALY

The heart of electric appliances ELECTRIC WATER HEATING MADE IN ITALY The heart of electric appliances ELECTRIC WATER HEATING MADE IN ITALY The heart of electric appliances MADE IN ITALY thermowatt.com 2 THERMOSTATS RTM 07 RTS 08 RTS PLUS 09 RTS ERP / RTS PLUS ERP 10 TES

More information

GENERAL CATALOGUE MICROMETRIC, THERMOSTATIC VALVES THERMOSTATIC VALVES MANUAL VALVES LOCKSHIELDS ACCESSORIES AND SPARE PARTS

GENERAL CATALOGUE MICROMETRIC, THERMOSTATIC VALVES THERMOSTATIC VALVES MANUAL VALVES LOCKSHIELDS ACCESSORIES AND SPARE PARTS GENERAL CATALOGUE MICROMETRIC, TERMOSTATIC VALVES TERMOSTATIC VALVES MANUAL VALVES LOCKSIELDS ACCESSORIES AND SPARE PARTS SUMMARY 1. USE 2. MICROMETRIC TERMOSTATIC VALVES 3. TECNICAL DATA 3. MATERIALS

More information

Catalog. Self-operated Regulators Volume 2 Temperature Regulators

Catalog. Self-operated Regulators Volume 2 Temperature Regulators Catalog Self-operated Regulators Volume 2 Temperature Regulators Self-operated Regulators Temperature Regulators Volume 2 Catalog 2012 Overview Self-operated Temperature Regulators 5 Self-operated Pressure

More information

Instruction FH-CWP Thermostat

Instruction FH-CWP Thermostat Instruction FH-CWP Thermostat Index Instruction FH-CWP Thermostat 1. Functional Overview.......................... 3 2. Mounting..................................... 4 3. Installation....................................

More information

Dear Customer. Contents. 1) Vantage Electric Radiator characteristics Pag.3. 2) Technical specifications Pag.3. 3) Warnings Pag.4

Dear Customer. Contents. 1) Vantage Electric Radiator characteristics Pag.3. 2) Technical specifications Pag.3. 3) Warnings Pag.4 IST 03 F 048-01 Dear Customer Thanks for choosing this Ecopower Heating product. Please read this manual carefully, as it contains important information on the correct and safe and installation of your

More information

Thermostatic valves with radiator connection systems

Thermostatic valves with radiator connection systems Multilux Eclipse Thermostatic valves with radiator connection systems with two-point connection for two-pipe heating systems, with automatic flow limitation IMI HEIMEIER / Thermostatic heads and Radiator

More information

Thermostatic Heads TT3000 TT3000C TT /02/2018. Technical Data Sheet

Thermostatic Heads TT3000 TT3000C TT /02/2018. Technical Data Sheet Technical Data Sheet Thermostatic Heads TT3000 TT3000C TT3002 15/02/2018 Function Thermostatic valves allow to make each room independent with a specific set temperature, thus enhancing comfort and actual

More information

OIL FILLED RADIATOR Instruction manual

OIL FILLED RADIATOR Instruction manual 5786001100 17-09-2001 12:19 Pagina 1 OIL FILLED RADIATOR Instruction manual 6 7 8 5 9 1 19 5786001100 17-09-2001 12:19 Pagina 2 fig. 1 fig. 2b fig. 2a P I II 1 MANUAL (Timer override) 4 3 2 24 23 22 21

More information

V2880, Therafix Design Thera Design Edition - H-Block with TRV Insert WITH HIGH QUALITY SURFACE FOR DESIGN RADIATORS

V2880, Therafix Design Thera Design Edition - H-Block with TRV Insert WITH HIGH QUALITY SURFACE FOR DESIGN RADIATORS W GE R MAN Y W GE R MAN Y V2880, Therafix Design Thera Design Edition - H-Block with TRV Insert WITH HIGH QUALITY SURFACE FOR DESIGN RADIATORS Design Angle left Straight W GE R MAN Y Angle right The Therafix

More information

MAKING MODERN LIVING POSSIBLE. Installation Guide. ECtemp 550. Electronic Intelligent Thermostat.

MAKING MODERN LIVING POSSIBLE. Installation Guide. ECtemp 550. Electronic Intelligent Thermostat. MAKING MODERN LIVING POSSIBLE Installation Guide ECtemp 550 Electronic Intelligent Thermostat www.eh.danfoss.com Danfoss A/S is not liable or bound by warranty if these instructions are not adhered to

More information

Heating controller with optimisation functions

Heating controller with optimisation functions TAC 2112 C-10-42 Heating controller with optimisation functions 1999.12 The TAC 2112 offers for control of hot water systems. The radiator circuit is controlled according to an outdoor -compensated reset

More information

Pedestal Range. Installation and user manual. Kiosk. Trafalgar. Tube. Issue 001 September 2017 ENGLISH UK IRL SmithsEP.co.uk

Pedestal Range. Installation and user manual. Kiosk. Trafalgar. Tube. Issue 001 September 2017 ENGLISH UK IRL SmithsEP.co.uk Pedestal Range Installation and user manual Kiosk Trafalgar Tube Issue 001 September 2017 ENGLISH UK IRL SmithsEP.co.uk Contents Introduction 2 Declaration of conformity 3 Symbols used in this guide 3

More information

Operating instructions Oil condensing boiler

Operating instructions Oil condensing boiler Operating instructions Oil condensing boiler COB COB-CS Boiler for heating Boiler with stratification cylinder Wolf GmbH Postfach 1380 D-84048 Mainburg Tel. +49-8751/74-0 Fax +49-8751/741600 Internet:

More information

CDE2TI, CDE2TIB, CDE2ECC, CDE2ECCB, CDE24ECC & CDE24ECCB AUS/NZ

CDE2TI, CDE2TIB, CDE2ECC, CDE2ECCB, CDE24ECC & CDE24ECCB AUS/NZ CDE2TI, CDE2TIB, CDE2ECC, CDE2ECCB, CDE24ECC & CDE24ECCB AUS/NZ 08/50841/3 Issue 3 1 614 770 250 250 13 : 17 605 605 2kW 2.4kW CDE2Ti(B) (Fig.3) CDE2ECC(B) & CDE24ECC(B) (Fig.2) 2 3 4 LCD x o eco X Y eco

More information

Flush individual room control for floor heating systems

Flush individual room control for floor heating systems Multibox Flush individual room control for floor heating systems Pressurisation & Water Quality Balancing & Control Thermostatic Control ENGiNEERiNG ADVANTAGE Multibox is used for decentralized control

More information

Automatic balancing valves ASV-PV (new generation) DN 32-50

Automatic balancing valves ASV-PV (new generation) DN 32-50 Automatic balancing valves ASV-PV (new generation) DN 32-50 ASV-PV DN 32-50 Description ASV whiteboard animation SMT/SI ASV valves are automatic balancing valves. Together with Danfoss presetting radiator

More information

A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

A B C D E F G H I J K L M N O P Q R S T U V W X Y Z A B C D E F G H I J K L M N O P Q R S T U V W X Y Z A B C D E F G H I J K L M N O P Q R S T U V W X Y Z Ambient temperature This is the air temperature within a 21 ºC room at any given time. It depends

More information

Programmable Towel Radiator Manual

Programmable Towel Radiator Manual Programmable Towel Radiator Manual Contents Description Page 3 Location Page 4 Mountings Page 5 Starting Up Page 6+7 Return To The Initial Settings Page 8 Time Setting Page 9 Setting The Temperature (Set-Points)

More information

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE TEcHnIcal InsTRucTIons PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE PHRIE 095 PHRIE 1 PHIE 095 PHIE 1 PHRIE 155 PHRIE 157 PHRIE 175 PHRIE 177 PHRIE 195 PHRIE 197 PHRIE 7 PHRIE

More information

T5000 LCD Digital Fan Coil Thermostat

T5000 LCD Digital Fan Coil Thermostat T5 T5 CD Digital Coil Thermostat For Internal Circulation Only T5 CD Digital Coil Thermostat T5 CD Digital Coil Thermostats are designed to control heating, cooling, or year round air conditioning unit

More information

Dynalux. Floor Heating Manifolds Underfl oor heating circuit manifold

Dynalux. Floor Heating Manifolds Underfl oor heating circuit manifold Dynalux Floor Heating Manifolds Underfl oor heating circuit manifold IMI HEIMEIER / Floor Heating Control / Dynalux Dynalux Dynalux adjusts the flow rate in the individual heating circuits directly in

More information

Calypso exact. Thermostatic Radiator Valves With stepless precision presetting

Calypso exact. Thermostatic Radiator Valves With stepless precision presetting Calypso exact Thermostatic Radiator Valves With stepless precision presetting IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Calypso exact Calypso exact Calypso exact thermostatic valve bodies are

More information

Connection set. Radiator connection set for thermostatic and manual operation Ø 12

Connection set. Radiator connection set for thermostatic and manual operation Ø 12 Connection set Radiator connection set for thermostatic and manual operation Data sheet for 1 7650 00 Issue 0405 Control valves Connection pipe Ø 12 L L = 600 1 7650 00 L = 1000 1 7650 01 Bypass bodies

More information

HYDROTHERM H - SERIES TOWEL RAIL H4 Model

HYDROTHERM H - SERIES TOWEL RAIL H4 Model HYDROTHERM H - SERIES TOWEL RAIL H4 Model H3 Model H2 Model 80 700 1100 1500 160 FEATURES Replaceable Copper Tube HEIGHT: 700mm + Hardwire WATTAGE: 70-200 Watt Efficient Design Local Product Heating element

More information

Thermostatic heads. Thermostatic Heads For all thermostatic valve bodies and radiators with integrated valves

Thermostatic heads. Thermostatic Heads For all thermostatic valve bodies and radiators with integrated valves Thermostatic heads Thermostatic Heads For all thermostatic valve bodies and radiators with integrated valves IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Thermostatic heads Thermostatic heads

More information

Design-Edition. Design-Edition Thermostatic valves and lockshields, sets

Design-Edition. Design-Edition Thermostatic valves and lockshields, sets Design-Edition Design-Edition Thermostatic valves and lockshields, sets IMI HEIMEIER / Design-Edition / Design-Edition Design-Edition The sets are an elegant solution for e. g. design radiators. A sublime

More information

VHX Valve Sets with RAX Thermostatic Sensor for Designer Radiators & Bathroom Towel Rails

VHX Valve Sets with RAX Thermostatic Sensor for Designer Radiators & Bathroom Towel Rails VHX Valve Sets with RAX Thermostatic Sensor for Designer Radiators & Bathroom Towel Rails Application VHX floor connection VHX wall connection The VHX-sets are specially designed for towel rails and designer

More information

Vacuum Saving Valve. ZP2V Series. With One-touch fitting type available!

Vacuum Saving Valve. ZP2V Series. With One-touch fitting type available! Vacuum Saving Valve Series Can restrict the reduction of vacuum pressure even when there is no workpiece. When multiple vacuum pads are operated by one vacuum generator, and some of them are not holding

More information

HERZ TS-3000 HERZ HERZ Armaturen A-1230 Vienna Richard-Strauss-Straße 22

HERZ TS-3000 HERZ HERZ Armaturen A-1230 Vienna Richard-Strauss-Straße 22 HERZ TS-3000 HERZ-3000 Connection system for radiators Thermostatic valve and shut-off return valve Standard sheet for 3691-3694 3791 3794 Issue 0702 G 3/4 Dimensions in mm 1 3002 31 Connection nipples

More information

CROMO manual mixer shower

CROMO manual mixer shower CROMO manual mixer shower CAUTION! THIS PRODUCT IS NOT THERMOSTATICALLY CONTROLLED Installation and operating instructions Installers please note these instructions are to be left with the user 2180810C

More information

Thermal Reset Limit Thermostats Electromechanical TW according to DIN EN 14597

Thermal Reset Limit Thermostats Electromechanical TW according to DIN EN 14597 1 202 Thermal Reset Limit Thermostats Electromechanical TW according to DIN EN 14597 RAK-TW.1..H RAK-TW.1..H.. Use Function Changeover switch (S.P.D.T.) 2-position thermal reset limit thermostat with single-pole

More information

RVA /109. Heating Circuit ZONE Controller. Instructions for the INSTALLER

RVA /109. Heating Circuit ZONE Controller. Instructions for the INSTALLER Heating Circuit ZONE Controller RVA 46.531/109 Zonal temperature controller for control of a lowtemperature heating system, for use with condensing gas boilers Instructions for the INSTALLER INDEX Page

More information

Cleaning unit for coolant. :_decftez`_>r_fr] Book No.: V2

Cleaning unit for coolant. :_decftez`_>r_fr] Book No.: V2 Cleaning unit for coolant :_decftez`_>r_fr] Book No.: 1271526-02 V2 Alfa Laval Separation AB Separator Manuals, dept. SKEL S-147 80 Tumba, Sweden Telephone: +46 8 53 06 50 00 Telefax: +46 8 53 03 10 40

More information

Waterbaths & Oilbaths

Waterbaths & Oilbaths Waterbaths & Oilbaths PRECISION AND SAFETY BROUGHT TO THE POINT. WATERBATH W OILBATH O 100% ATMOSAFE. MADE IN GERMANY. www.memmert.com www.atmosafe.net 2 Uniquely precise and reliable. Of course always

More information

Zip Tudor. Affix Model Number Label Here Installation Section & Operating Heading Instructions. Single point open outlet (vented) water heaters

Zip Tudor. Affix Model Number Label Here Installation Section & Operating Heading Instructions. Single point open outlet (vented) water heaters Zip Tudor Installation Section & Operating Heading Instructions Single point open outlet (vented) water heaters Affix Model Number Label Here 81333 Above-Sink Tudor (No tapware included) Accessory Tapware

More information

STREAMLINE OVERSINK. Fitting Instructions and User Guide _iss_05.indd 1 15/09/ :46:30

STREAMLINE OVERSINK. Fitting Instructions and User Guide _iss_05.indd 1 15/09/ :46:30 STREAMLINE OVERSINK Fitting Instructions and User Guide 1 36005997_iss_05.indd 1 15/09/2015 08:46:30 CONTENTS SECTION PAGE 1.0 INTRODUCTION 3 2.0 TECHNICAL SPECIFICATIONS 4 3.0 INSTALLATION 6 4.0 COMMISSIONING

More information

living connect, Electronic Radiator Thermostat

living connect, Electronic Radiator Thermostat Application which will synchronize the other electronic radiator thermostats in the same room. living connect features an open-window function, which closes the valve if the temperature in the room is

More information

Multibox 4. Floor Heating Controller Flush individual room control for floor heating systems with supply shut-off

Multibox 4. Floor Heating Controller Flush individual room control for floor heating systems with supply shut-off Multibox 4 Floor Heating Controller Flush individual room control for floor heating systems with supply shut-off IMI HEIMEIER / Floor Heating Control / Multibox 4 Multibox 4 RTL and K-RTL and K-RTL is

More information

Overview Frost Heave Prevention for Freezer floors on ground.

Overview Frost Heave Prevention for Freezer floors on ground. PLEASE NOTE The floor sensor MUST be installed such that it may be REMOVED for service if required! The sensor probe should be installed into a conduit with no more than one wide-angle bend. This should

More information

12/50 CENTRIFUGAL PUMPS FOR DC SUPPLY OPERATING INSTRUCTIONS

12/50 CENTRIFUGAL PUMPS FOR DC SUPPLY OPERATING INSTRUCTIONS 12/50 CENTRIFUGAL PUMPS FOR DC SUPPLY OPERATING INSTRUCTIONS Please leave this instruction booklet with the pump as it contains maintenance and safety information (Original Instructions) MODELS 12/50 INDEX.................

More information

Installer Manual KNX Touchscreen Thermostat

Installer Manual KNX Touchscreen Thermostat Installer Manual 02952 KNX Touchscreen Thermostat Index GENERAL FEATURES AND FUNCTIONALITY from page 5 ETS PARAMETERS AND COMMUNICATION OBJECTS from page 7 COMMUNICATION OBJECTS GENERAL FEATURES AND FUNCTIONALITY

More information

Refrigerant valves. Valves for precise control and optimum energy efficiency in refrigeration systems. Answers for infrastructure.

Refrigerant valves. Valves for precise control and optimum energy efficiency in refrigeration systems. Answers for infrastructure. Refrigerant valves Valves for precise control and optimum energy efficiency in refrigeration systems Answers for infrastructure. MVL661.. MVS661..N and matching ASR valve insert The new generation MVL661..

More information

TA-SCOPE. Balancing instrument ENGINEERING ADVANTAGE

TA-SCOPE. Balancing instrument ENGINEERING ADVANTAGE Instruments TA-SCOPE Balancing instrument Pressurisation & Water Quality Balancing & Control Thermostatic Control ENGINEERING ADVANTAGE TA-SCOPE is a tough, effective balancing instrument for measuring

More information

Operating Guide: for the Warmup tempo Digital Programmable Thermostat Part of the Element Series Introduction

Operating Guide: for the Warmup tempo Digital Programmable Thermostat Part of the Element Series Introduction Operating Guide: for the Warmup tempo Digital Programmable Thermostat Part of the Element Series Introduction The tempo has been designed with simplicity in mind and is highly intuitive in its programming.

More information

KTX 1, KTX 2, KTX 3, KTX 4. User Manual Electric Heating KTX 1, KTX 2, KTX 3, KTX 4.

KTX 1, KTX 2, KTX 3, KTX 4. User Manual Electric Heating KTX 1, KTX 2, KTX 3, KTX 4. KTX 1, KTX 2, KTX 3, KTX 4. User Manual Electric Heating KTX 1, KTX 2, KTX 3, KTX 4. en Our products have been designed and manufactured in such a way to ensure that all the quality, functionality and

More information

Frost Units for air temperature monitoring

Frost Units for air temperature monitoring 284 284P0 Frost Units for air temperature monitoring QAF8... Robust aluminium die-cast housing Responds to temperature change sensed over any 30 cm length of capillary Small switching differential Good

More information

USER MANUAL AND TECHNICAL MANUAL

USER MANUAL AND TECHNICAL MANUAL USER MANUAL AND TECHNICAL MANUAL Kanmed Universal Warming Cabinets Kanmed Blanket Warming Cabinets Kanmed Combination Cabinet GE-2300-070 / 4 2014-05-12 NOTE: This manual contains important information

More information

Raychem Heating System

Raychem Heating System Raychem Heating System Tank Heater (H55207) Approvals F M APPROVED Ordinary and Hazardous Locations lass I, Div. 2, Groups B,, D lass II, Div. 1 & 2, Groups E, F, G lass III All hazardous location applications

More information

ST325. Thermostat. The ST325TX can be used with any of these receivers RXBC605 RXST625 RXRT505 RXVBC605 RXWBC MHz

ST325. Thermostat. The ST325TX can be used with any of these receivers RXBC605 RXST625 RXRT505 RXVBC605 RXWBC MHz ST325TX Manual Version 008_Layout 1 16/05/2013 09:02 Page 1 ST32 ST S T325 32 25 5TX TX ST3 T3 325T 32 25TX ST T3 325 25TX ST S T32 25T TX TX ST325TX Digital Room ST325 T3 5 5TX T X Thermostat RXBC605

More information

Dear Customer, We wish that this product, manufactured at modern facilities with total quality notions, will deliver you the best performance.

Dear Customer, We wish that this product, manufactured at modern facilities with total quality notions, will deliver you the best performance. Dear Customer, We wish that this product, manufactured at modern facilities with total quality notions, will deliver you the best performance. In order to guarantee this, please read this instruction manual

More information

Rotameter series 250 metal tube variable area flowmeter

Rotameter series 250 metal tube variable area flowmeter Technical data Sheet Flow meter Rotameter series 250 metal tube variable area flowmeter MODELES 250 Stainless Steel indicator 250 PTFE 250 indicator + Alarm 250 electronic transmitter 4-20mA 250 electronic

More information

MR4PMUHV Electronic. Temperature/Defrost Control with Relay Pack

MR4PMUHV Electronic. Temperature/Defrost Control with Relay Pack Master Catalog 125 Temperature Controls Section A Product/Technical Bulletin Issue Date 1098 MR4PMUHV Electronic Temperature/Defrost Control with Relay Pack The MR series temperature controls are designed

More information

Installation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump

Installation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump Installation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump Reduced Installation time Precision regulation Minimal tooling required 100% tested prior to packaging High quality

More information