SUPPLEMENT PARTS LISTING WIRING DIAGRAMS FOR MT-25,40 & 60EO - KETTLES
|
|
- Randall Butler
- 5 years ago
- Views:
Transcription
1 SUPPLEMENT PARTS LISTING & WIRING DIAGRAMS FOR MT-25,40 & 60EO - KETTLES FORM # S This supplement is based on HEATING ELEMENT CONFIGURATIONS ( see attachments ) titled by styles. Each STYLE is identified with a serial number and corresponding part numbers. In addition, a supporting SPARE PARTS LIST will help identify the most commonly used components for STYLES 2-3-&- 4.A brief description of each style is as follows: STYLE 1: This style is the original version and it is supported by the service & parts manual form # S-2312 rev. 6/85. STYLE 2: This style began with SERIAL NUMBER ( ) and is supported by the spare parts list attached. Uses ( 2 ) screw - in heaters, each rated at 12KW ( SEE ATTACHED WIRING DIAGRAM D ) STYLE 3: This style began with SERIAL NUMBER ( ) and is supported by the attached spare parts lists. Uses a one piece heater design that replaced the heating element configuration outlined in STYLE 2. (SEE ATTACHED WIRING DIAGRAM D ) STYLE 4: This is our current design which began with SERIAL NUMBER ( ) and is supported by the attached spare parts list. Uses ( 2 ) bolt in flanged heaters, each rated at 12KW (SEE ATTACHED WIRING DIAGRAM D ) Revised: 7 / 94
2 Market Forge Ind. HTG. ELE. CONFIGURATIONS FOR MT & -60EO BOILERS STYLE 1 OLDER MODELS COMPONENTS: P/N DESCRIPTION QTY. STATUS HTG.ELE..208V-8KW 3 AVAILABLE HTG.ELE..240V-8KW 3 AVAILABLE HTG. ELE., 480V-8KW 3 AVAILABLE COMPONENTS: P/N DESCRIPTION QTY. STATUS HTG.ELE.,208V-12KW 2 OBS. TO HTG. ELE., 240V- 12KW 2 OBS. TO HTG. ELE., 480V- 12KW 2 OBS. TO PLATE, GASKET 1 AVAILABLE WELDMENT, CVR. PLATE 1 OBS.N.L. A. 35 GARVEY STREET, EVERETT. MA Page 1 MT - - EO:XLS
3 Market Forge Ind. STYLE 3 BEGINING WITH SER # * COMPONENTS: P/N DESCRIPTION QTY. STATUS KTG.ELE., 208V-24KW 1 AVAILABLE HTG.ELE., 240V-24KW 1 AVAILABLE HTG.ELE., 480V-24KW 1 AVAILABLE PLATE, GASKET 1 AVAILABLE STYLE 4 BEG1NING WITH SER # * COMPONENTS: P/N DESCRIPTION QTY. STATUS HTG.ELE., 208V-12KW 2 AVAILABLE HTG. ELE.. 240V - 12KW 2 AVAILABLE HTG. ELE.. 480V- 12KW 2 AVAILABLE GASKET. HTG. ELE. 2 AVAILABLE GASKET, ACCESS CVR. 1 AVAILABLE 6** WASHER, SEALING 12 AVAILABLE 7** HX.HD.1/4-20 X7/8" 12 AVAILABLE 8** LOCKWASHER, 1/4 12 AVAILABLE 9** SIGHT GLASS 1 AVAILABLE 10** REFLECTOR 1 AVAILABLE WELDMENT, CVR. PLATE 1 AVAILABLE * INDICATES THAT THERE MAY BE AN OVERLAP BETWEEN STYLE (3) AND STYLE (4) ** INDICATES COMMON PARTS BETWEEN STYLES & GARVEY STREET. EVERETT. MA Page 2 MT - - EO:XLS
4 MODEL: MT 25, 40 and 60EO BOILERS SPARE PARTS LIST STYLES: 2-3 & 4 PROBE LEVEL CONTROL QTY. PART NUMBER DESCRIPTION LIQUID LEVEL CONTROL BD. (120 volt) LIQUID LEVEL CONTROL BD. ( 240 volt) LIQUID LEVEL PROBE (-water fill) LIQUID LEVEL PROBE (low water level) WATER SUPPLY VALVES SKINNER VALVE ( 120 VOLT ) REMOVABLE STRAINER FOR SKINNER VALVE DRAIN VALVES DRAIN VALVE DRAIN VALVE REPAIR KIT ( new style ) BOILER SHELL SHELL, BOILER FOR STYLE 2 & 3 BOILERS SHELL, BOILER FOR STYLE 4 BOILERS ONLY! ELECTRICAL COMPONENTS TIME DELAY RELAY (120 volt) THERMOSTAT ( drain condensate ) ON - OFF SWITCH S.P.S.T HEAT SWITCH D.P.D.T. ( momentary ) CONTACTOR 40 AMP (120 VOLT COIL ) PILOT LIGHT RELAY SOCKET PRESSURE SWITCHES PRESSURE SWITCH ( high limit) PRESSURE SWITCH ( operating pressure ) MISCELLANEOUS HARDWARE & PLUMBING PRESSURE GAUGE AIR VENT # SAFETY VALVE GASKET. HTG. ELEMENT COVER STYLE 2 & 3 BOILERS GASKET. HTG. ELEMENT COVER STYLE 4 BOILERS ONLY! WATER GAUGE WATER GAUGE GLASS REFLECTC OR DESCALER Page 3 MT40E01.XLS
5 Industries Inc. Employee Owned Company 35 Garvey St.. Everett MA Tel (617) Service Bulletin SB0002 April 24, 1995 TO ALL SERVICE MANAGERS SERVICE BULLETIN NO. SB0002 SUBJECT: MT25,40 & 60EO - KETTLES FORM # S-2312 This bulletin is based on a recent change to the following HEATING ELEMENTS and related wiring NEW LIST PRICE Heating Element Part Number: S Volt Heating Element Part Number: S Volt Heating Element Part Number: S Volt N/A Market Forge has obsoleted Part Number S ( 480 Volt heating element). This application will now be serviced by using Part Number S ( 240 Volt heating element) in its place and wiring the 480 Volts in series across two of the 240 Volt loops ( see attached wiring sketches ). These wiring diagrams will help assist your technician during the install of these new heaters. The Part Number S ( 208 Volt heating element) will remain the same, however, the wiring changes will apply. Please note that the gasket for this heating element is not included with the sale. You will need to order the following Part Number S to support the installation. If you should have any questions concerning this bulletin, please do not hesitate to call either Ms. Lorraine Murphy X179 or myself directly X126. Be sure to make note of the NEW LIST PRICE' Sincerely, Mark Manganiello Sale Administration / Service Manager
6 MT 25, 40 and 60EO WIRING DIAGRAMS FOR STYLE 2 and 3 HEATING ELEMENT REPLACEMENTS WIRING DIAGRAM FOR VOLT 3 PHASE 60 HZ 24 KW. VOLTS AMPS PART NO. ELEMENT Indicates Metal Jumper S S WIRING DIAGRAM FOR 480 VOLT 3 PHASE 60 HZ. 24 KW Indicates Metal Jumper VOLTS AMPS PART NO. ELEMENT S ( 240 VOLT ) NOTE: WHEN USING THIS ELEMENT, SPECIAL CARE MUST BE TAKEN TO REMOVE AND ALIGN THE JUMPERS PROPERLY. Market Forge Industries, Inc. MTEODIA1.XLS
7 Leaders in Foodservice Equipment for over a century. July 5, 1988 TO: ALL PARTS DISTRIBUTORS FROM: DONNA CESINO SUBJECT: NEW HEATING ELEMENTS FOR ULTRA STEAM MODELS: 3005, 3010, 3015 We are discontinuing the following cartridge type heating elements: Part # Description Element, 208 volt. 3 phase Element, 240 volt, 3 phase Element, 208 volt. 1 phase Element, 240 volt, 1 phase The above part numbers will be replaced with a new firebar type heating element. The firebars are very low watt density, resist scale build-up, and are less costly than the original heaters. More good news... one firebar takes the place of (2) 5 KW elements for model 3010 steamer at a good saving for the customer. Firebars also can be connected one or three phase so your stock level is less. Part numbers for Firebar: Part # Description V, 5 KW V, 5 KW V, 10 KW V, 10 KW For easy reference: Model Use Firebar # V 1 or 3 ph
8 Model Use Firebar # V 1 or 3 ph V 1 or 3 ph V 1 or 3 ph V * overall wattage of this model is 1 or 3 ph now reduced from 15 KW to 10 KW V 1 or 3 ph * Overall wattage of this model is now reduced from 15 KW to 10 KW Regards, DC/lh
9 MARKET FORGE COMPANY WIRING DIAGRAM FIREBAR HEATERS ULTRA STEAM MODELS - 5 & 10 KW
Self-Contained Electric Steam Jacketed Kettle
OWNERS MANUAL Self-Contained Electric Steam Jacketed Kettle Model: FT-20CE COVERING: INSTALLATION OPERATION SERVICE & PARTS An Employee Owned Company 35 Garvey Street l Everett l MA l 02149 Tel: (617)
More informationEffective october 14, 2014
COS-101 & COS-101S COMBI OVEN STEAMER REPLACEMENT PARTS LIST Effective october 14, 2014 Superseding All Previous Parts Lists. The Company reserves the right to make substitution in the event that items
More informationCMA Dishmachines Knott Avenue Garden Grove, CA Undercounter High Temperature Dishwasher. Service Replacement Parts.
CMA Dishmachines 1700 Knott Avenue Garden Grove, CA 981 Toll Free: 1- (800) 8-617 Fax: 1- (71) 89-11 Service Replacement Parts Undercounter High Temperature Dishwasher Model: UC6e M Machine Serial No.
More informationECOJET EJ-10E & EJ-7E ELECTRIC CONVECTION STEAMER W/TWIN GENERATORS PARTS AND SERVICE MANUAL
ECOJET EJ-10E & EJ-7E ELECTRIC CONVECTION STEAMER W/TWIN GENERATORS PARTS AND SERVICE MANUAL EFFECTIVE JULY 31, 2014 Superseding All Previous Parts Lists. The Company reserves the right to make substitution
More informationEffective october 14, 2014
COS-20G combi oven-steamer REPLACEMENT PARTS LIST Effective october 14, 2014 Superseding All Previous Parts Lists. The Company reserves the right to make substitution in the event that items specified
More informationPS-3E AND PS-6E ELECTRIC CONVECTON STEAMERS PARTS AND SERVICE MANUAL
PS-3E AND PS-6E ELECTRIC CONVECTON STEAMERS PARTS AND SERVICE MANUAL EFFECTIVE AUGUST 1, 2014 Superseding All Previous Parts Lists. The Company reserves the right to make substitution in the event that
More informationStatement of Responsibilities
Statement of Responsibilities This document is for use by experienced and trained Qualified Cleveland Range, LLC Authorized Service Representatives who are familiar with both the safety procedures, and
More informationFCT-CE SERIES ELECTRIC TILTING KETTLE W/HAND CRANK PARTS AND SERVICE MANUAL
FCT-CE SERIES ELECTRIC TILTING KETTLE W/HAND CRANK PARTS AND SERVICE MANUAL EFFECTIVE SEPTEMBER 12, 2014 Superseding All Previous Parts Lists. The Company reserves the right to make substitution in the
More informationReplacement Parts List For Models COS-20G
Replacement Parts List For Models COS-20G (Ovens with s/n HP & HT) Contents: Page # Electrical Compartment:Contactors,Steam Generator,Thermostats 2-5 Oven Interior: 5 Bottom Section: Gas, Plumbing Components
More informationMP GS/GD 10 GAS. Toll Free Phone, (US & Canada): (800) Toll Free Fax, (US & Canada): (800)
MP GS/GD 0 GAS Toll Free Phone, (US & Canada): (800) 427-6668 Toll Free Fax, (US & Canada): (800) 36-7745 http://www.garland-group.com FORM # Moisture Plus Gas GS/GD0 (Rev 5) Page 2 FORM # Moisture Plus
More informationME SERIES ELECTRICALLY OPERATED BOILERS INSTALLATION - OPERATION - MAINTENANCE MODELS
ME SERIES ELECTRICALLY OPERATED BOILERS INSTALLATION - OPERATION - MAINTENANCE MODELS M24E M36E Telephone: (802) 658-6600 Fax: (802)864-0183 www.marketforge.com PN 14-0309 Rev G (11/17) 2017 - Market Forge
More informationStatement of Responsibilities
Statement of Responsibilities This document is for use by experienced and trained Qualified Cleveland Range, LLC Authorized Service Representatives who are familiar with both the safety procedures, and
More informationModel 10AB/APRB Automatic Dishwasher
Model 10AB/APRB Automatic Dishwasher Rinse and Wash Head Assemblies ITEM 1 0126800 End Plug 2 0125000 Rinse Arm Body (only) 3 0126000 Nylatron Washer (2 places) 4 0125500 Hex Nut 5 0126500 Snap Ring 6
More informationCleveland Range REPAIR MANUAL
Cleveland Range REPAIR MANUAL Model No. 6/9CEM18/27/36/48 6/9CGM100/200/250/300 6/9CDM 6/9CSM UNITED STATES 1333 East 179th St. Cleveland, Ohio 44110 Phone: (216) 481-4900 FAX: (216) 481-3782 Cleveland
More informationReplacement Parts List For Models COS-101 COS-101S
Replacement Parts List For Models COS-101 COS-101S (Ovens with s/n HD, HE, HG, HJ) Contents: Page # Front View: Control Panel, Door, Exterior Components 2-4 Oven Interior: 5 Bottom Section: Plumbing Components
More informationRENEWAL PARTS IDENTIFICATION. Type TTUH and TTUH-CO URN Heaters. Dimensions (In.) Extends. Model Volts kw W/In 2 A B C D
Chromalox Installation, Operation and RENEWAL PARTS IDENTIFICATION DIVISION DATE SALES REFERENCE (Supersedes PD00-1) OCTOBER, 000 SECTION TTUH PD00-15 161-0815-001 Type TTUH and TTUH-CO URN Heaters TTUH-0A
More informationMODEL CMA-180UC PARTS MANUAL Rev 1.18
MODEL CMA-180UC PARTS MANUAL Rev 1.18 CMA DISHMACHINES 12700 KNOTT AVENUE GARDEN GROVE, CALIFORNIA 92841 800-854-6417 FAX 714-895-2141 wwwcmadishmachines.com TABLE OF CONTENTS MODEL CMA-180UC 1. PARTS
More informationStatement of Responsibilities This document is for use by experienced and trained Qualified Cleveland Range, LLC Authorized Service Representatives who are familiar with both the safety procedures, and
More informationSCE170 SERVICE PARTS
This is the parts list for the SCE170. When looking up part numbers, always check the complete model and serial numbers to be certain of ordering the correct parts. The SCE170 has been manufactured in
More informationMODEL CMA-180UC PARTS MANUAL Rev 1.16
MODEL CMA-180UC PARTS MANUAL Rev 1.16 CMA DISHMACHINES 12700 KNOTT STREET GARDEN GROVE, CALIFORNIA 92841 800-854-6417 FAX 714-895-2141 wwwcmadishmachines.com TABLE OF CONTENTS MODEL CMA-180UC 1. PARTS
More informationStatement of Responsibilities
Statement of Responsibilities This document is for use by experienced and trained Qualified Cleveland Range, LLC Authorized Service Representatives who are familiar with both the safety procedures, and
More informationSTEAMPRO. Steam Generator Troubleshooting and Service Guide
STEAMPRO Steam Generator Troubleshooting and Service Guide TABLE OF CONTENTS Page PREFACE... 1 I. STEAMPRO STEAM GENERATOR SYSTEM...2 II. PLUMBING AND ELECTRICAL...3-4 III. SYSTEM OVERVIEW... 5-10 IV.
More informationCOS-101 NON SELF FLUSHING COMBI REPLACEMENT PARTS LIST
COS-101 NON SELF FLUSHING COMBI REPLACEMENT PARTS LIST EFFECTIVE FEBRUARY 16, 2012 Superseding All Previous Parts Lists. The Company reserves the right to make substitution in the event that items specified
More informationCROWN SERVICE MANUAL ELECTRIC COUNTERTOP STEAMERS MODELS: PX-3 PX-5
CROWN SERVICE MANUAL ELECTRIC COUNTERTOP STEAMERS MODELS: PX-3 PX-5 CROWN FOOD SERVICE EQUIPMENT LTD. 70 OAKDALE ROAD, DOWNSVIEW, (TORONTO), ONTARIO, M3N 1V9 TELEPHONE: (416) 746-2358, FAX: (416) 746-8324
More informationParts Manual. Counter Type Electric Convection Steamer. Series: SteamCraft Models 21CET East 179 th Street Cleveland, Ohio 44110
Parts Manual Counter Type Electric Convection Steamer Series: SteamCraft Models 21CET8 1333 East 179 th Street Cleveland, Ohio 44110 Phone: (216) 481-4900 1-800-338-2204 Fax: (216) 481-3782 www.clevelandrange.com
More informationStatement of Responsibilities
Statement of Responsibilities This document is for use by experienced and trained Qualified Cleveland Range, LLC Authorized Service Representatives who are familiar with both the safety procedures, and
More informationPARTS MANUAL. American Dish Service ADS CONVEYOR DISHWASHER MODELS: ADC-44 L-R/R-L EFFECTIVE: SEPTEMBER 1, 2001
EFFECTIVE: SEPTEMBER 1, 2001 ADS CONVEYOR DISHWASHER MODELS: ADC-44 L-R/R-L PARTS MANUAL 900 Blake Street Edwardsville, Kansas 66111 (913)422-3700 211-0044L-R / 212-0044R-L ADC-44 Conveyor Dishwasher 2
More information5700 SERIES CONFINED SPACE UNIT HEATER Horizontal or Vertical Mounting
5700 SERIES CONFINED SPACE UNIT EATER orizontal or Vertical Mounting MAINTENANCE MANUAL & INSTALLATION INSTRUCTIONS ATTENTION: Read carefully before attempting to install or operate Unit eater. I NTERTEK
More informationALTAIR II CONVECTION STEAM COOKER PARTS AND SERVICE MANUAL
ALTAIR II CONVECTION STEAM COOKER PARTS AND SERVICE MANUAL EFFECTIVE MAY, 0 Superseding All Previous Parts Lists. The Company reserves the right to make substitution in the event that items specified are
More informationElectro-HELPS XV ELECTRO-BOILER SPECIFICATIONS. A complete product line to fi t all your application needs. Made in USA
Electro-HELPS XV Made in USA ELECTRO-BOILER SPECIFICATIONS A complete product line to fi t all your application needs The Electro-Boiler has been heating America s homes and businesses since 980. We take
More informationOWNER S MANUAL MODULAR DIRECT CONNECTED TILTING STEAM JACKETED KETTLE
OWNER S MANUAL MODULAR DIRECT CONNECTED TILTING STEAM JACKETED KETTLE MODELS: MT6 MT6T6 MT10 MT10T10 MT10T6 LFT6 LFT10 LFT10T6 LFT10T10 Form Number: S-2306 REV:C 10/12 Printed in U.S.A. 35 Garvey Street
More informationTable of Contents. FETCO, and Driven To Pioneer Innovation are trademarks or trade names of Food Equipment Technologies Company.
www.fetco.com Hot Water Dispensers User s Guide Maritime Versions Rated IP44 Table of Contents Contact Information... 2 Specifications... 2 Dimensions... 3 Installation... 4 Operating Instructions...6
More information3500 SERIES CONVECTION STEAM COOKER PARTS AND SERVICE MANUAL
3500 SERIES CONVECTION STEAM COOKER PARTS AND SERVICE MANUAL EFFECTIVE JULY 30, 2014 Superseding All Previous Parts Lists. The Company reserves the right to make substitution in the event that items specified
More informationMODELS R & RH 10 THRU 20 RB SERIES ELECTRIC STEAM BOILERS
REIMERS ELECTRA STEAM, INC. 4407 MARTINSBURG PIKE CLEAR BROOK, VA 22624-0037 PHONE:540-662-3811 FAX:540-665-8101 April 01, 2001 MODELS R & RH 10 THRU 20 RB SERIES ELECTRIC STEAM BOILERS INSTALLATION, OPERATING,
More informationGMOS Series OIL-FIRED CAST IRON STEAM BOILER PARTS AND OPTIONAL ACCESSORIES
MODELS GMOS-3090 GMOS-3090T GMOS-425 GMOS-425T GMOS-585 GMOS-585T GMOS-620 GMOS-620T Ordering Instructions GMOS Series OIL-FIRED CAST IRON STEAM BOILER PARTS AND OPTIONAL ACCESSORIES Order Parts through
More informationMODELS CMA-180 VL/180 VLTall PARTS MANUAL Rev 2.02A
MODELS CMA-180 VL/180 VLTall PARTS MANUAL Rev 2.02A C M A D I S H M A C H I N E S 1 2 7 0 0 K N O T T A V E N U E GARDEN GROVE, CALIFORNIA 92841 800-8 5 4-6 4 1 7 FAX 714-895-2141 www.cmadishmachines.com
More informationInstruction Manual HWR MODEL RESISTO-FLO ELECTRIC BOILER
Page 1 of 16 Instruction Manual HWR MODEL RESISTO-FLO ELECTRIC BOILER Page 2 of 16 FOREWORD The HWR Resisto-Flo Electric Hot Water Boiler is designed to provide a compact packaged unit requiring a minimum
More informationINTRODUCTION THIS MANUAL INCLUDES IMPORTANT SAFETY INFORMATION
INSTALLATION AND OPERATING INSTRUCTIONS FOR THE HARDY Fuel Oil Furnace Models D-140 & D-350 HARDY MANUFACTURING COMPANY, INC. 12345 ROAD 505 PHILADELPHIA, MS 39350 PHONE: (601) 656-5866 FAX: (601) 656-4559
More informationCME1856W Service Parts
This parts list contains the part numbers and description of the replacement parts available for this model. To avoid costly and time consuming errors, double check the model and voltage before ordering
More informationUltra Boiler Series 1 & 2 Jacket Parts
GAS Ultra Boiler Series 1 & 2 Jacket Parts 9 10 8 6 7 1 5 2 3 Fig. Part Description Model Mfr. 1 383-500-135 Jacket Front Door 595-000-000 595-000-001 595-000-002 595-000-003 Panel Door Jacket Plastic
More informationMODELS CMA-180 VL/180 VLTall PARTS MANUAL Rev 2.02B
MODELS CMA-180 VL/180 VLTall PARTS MANUAL Rev 2.02B C M A D I S H M A C H I N E S 1 2 7 0 0 K N O T T A V E N U E GARDEN GROVE, CALIFORNIA 92841 800-8 5 4-6 4 1 7 FAX 714-895-2141 www.cmadishmachines.com
More informationTubular Industrial Process
consist of tubular elements welded or brazed into a threaded screw plug which can then be inserted into a threaded opening in a tank wall or through a mating full or half coupling. Standard Screw Plug
More informationResidential Upright Residential Lowboy
RESIDENTIAL ELECTRIC REPLACEMENT PARTS LIST Residential Upright Residential Lowboy Includes Hydrojet Total Performance System Effective: April, 2016 ECO 8039 NOTE: BOTH MODEL AND SERIAL NUMBERS ARE REQUIRED
More informationMcQuay. Vertical Water Source Heat Pump. FCV, FCG, FCW 036, 042 Vintage A. Last Manufactured: 1993
Replacement Parts List No. 055237600 Revision D 08/2017 McQuay Vertical Water Source Heat Pump FCV, FCG, FCW 036, 042 Vintage A Last Manufactured: 1993 To find your Daikin Applied parts distributor, call
More informationOWNER S MANUAL MODELS: ELECTRIC COMPACT CONVECTION OVEN. FORM NO.: S-2374 REV: A 02/07 An Employee Owned Company
OWNER S MANUAL ELECTRIC COMPACT CONVECTION OVEN MODELS: 4200 4292 FORM NO.: S-2374 REV: A 02/07 An Employee Owned Company PRINTED IN U. S. A. 35 Garvey Street Everett MA 02149 Tel: (617) 387-47100 Fax:
More informationModel: FT110 Dishwasher
PARTS MANUAL HOBART FOOD EQUIPMENT CO., LTD Model: FT110 Dishwasher HOBART FOOD EQUIPMENT CO., LTD 2003-07-10 Table of Contents Page Description 2 Panels, Upper chamber and Tank 4 Control Box 6 Control
More informationQuantity X Section Assembly (Intermittent and Continuous Circulation Only)
V. Repair Parts Section Assembly and Canopy Group...30 Base Assembly...3 Manifold and Main Burners Inch Main Burners...34 40mm Main Burners...36 Pilot Burner and Gas Valve Continuous Ignition (Standing
More informationMSA-SB-2600 MILITARY SUB-ASSEMBLY HIGH EFFICIENCY ELECTRIC CONVECTION OVEN; OWNER S MANUAL
S6163-B8-FSE-010 0910-LP-106-4844 TECHNICAL MANUAL MSA-SB-2600 MILITARY SUB-ASSEMBLY HIGH EFFICIENCY ELECTRIC CONVECTION OVEN; OWNER S MANUAL DISTRIBUTION STATEMENT C: DISTRIBUTION AUTHORIZED TO U.S. GOVERNMENT
More informationAssembly Code Identity Data System. Omniclass Number and Title
Category Part Type Parameter Name Parameter Group Parameter Type GUID Discipline Type Of Parameter Specialty Equipment Default Elevation Constraints Assembly Code Identity Data Cost Description Keynote
More informationDaikin McQuay. EnerSaver Packaged Terminal Air Conditioner/Heat Pump. PNES; PNHS Design D (4)
Replacement Parts List No. 700018800 Revision C 08/2012 Daikin McQuay EnerSaver Packaged Terminal Air Conditioner/Heat Pump PNES; PNHS 009-015 Design D (4) To find your Daikin Applied parts distributor,
More informationMcQuay. Concealed Ceiling Water Source Heat Pump. WCAE, WCAS, WCDA, WCDL, WCDS, WCMS 024, 030 Design A (1)
Replacement Parts List No. 110510700 Revision G 02/2015 McQuay Concealed Ceiling Water Source Heat Pump WCAE, WCAS, WCDA, WCDL, WCDS, WCMS 024, 030 Design A (1) WCAS, WCDA, WCDL, WCDS, WCMS 030 Design
More informationIndirect Fired Water Heater
Indirect Fired Water Heater 35-119 Gallon Capacities Features Heavy Duty Construction Hydrastone cement lining provides long tank life Copper-silicon tappings cannot rust or corrode High impact composite
More informationCME1856W Service Parts
This parts list contains the part numbers and description of the replacement parts available for this model. To avoid costly and time consuming errors, double check the model and voltage before ordering
More informationInstallation and Maintenance Manual Please retain this manual for future reference.
342 N. Co. Rd. 400 East Valparaiso, IN 46383 219-464-8818 Fax 219-462-7985 www.heatwagon.com Installation and Maintenance Manual Please retain this manual for future reference. Electric Construction Heaters
More informationCool IR. Model C104 - Cooling System. Instruction Manual
Cool IR Model C104 - Cooling System Instruction Manual February 26, 2015 Research, Inc. USA Ph: 952.949-9009 Fax: 952.949-9559 tsdsales@researchinc.com www.researchinc.com Table of Contents List of Figures...
More informationHOLDING DRAWERS INTENDED FOR OTHER THAN HOUSEHOLD USE THIS MANUAL FOR FUTURE REFERENCE KEPT CLEAR OF COMBUSTIBLES AT ALL TIMES
X*PERT TM SERIESS INSTALLATION AND OPERATING INSTRUCTIONS MODE EL: HDDi/HDDiS/HDXi HOLDING DRAWERS INTENDED FOR OTHER THAN HOUSEHOLD USE RETAIN THIS MANUAL FOR FUTURE REFERENCE UNIT MUST BE KEPT CLEAR
More informationParts Manual. Gas Floor Type Convection Steamer. Series: SteamCraft Model 24CGA East 179 th Street Cleveland, Ohio 44110
Parts Manual Gas Floor Type Convection Steamer Series: SteamCraft Model 24CGA10 1333 East 179 th Street Cleveland, Ohio 44110 Phone: (216) 481-4900 1-800-338-2204 Fax: (216) 481-3782 www.clevelandrange.com
More informationBarrier Washer. Parts. Refer to Page 3 for Model Numbers. BAR18P_
Barrier Washer Refer to Page 3 for Model Numbers Parts BAR18P_1300625 www.alliancelaundry.com Part No. 1300625R4 August 2014 Table of Contents Title Page Parts Ordering Information... 2 Serial Plate Location...
More informationMODELS R & RH 24 THRU 120 ELECTRIC STEAM BOILERS
REIMERS ELECTRA STEAM, INC. 4407 MARTINSBURG PIKE CLEAR BROOK, VA 22624-0037 PHONE: 540-662-3811 FAX: 540-665-8101 04/01/04 MODELS R & RH 24 THRU 120 ELECTRIC STEAM BOILERS INSTALLATION, OPERATING, & MAINTENANCE
More informationMcQuay. Console Water Source Heat Pump. WMH, WMG, WMK, WCH, WCG 015, 019 Vintage A. Last Manufactured: 1993
Replacement s List No. 55209100 Revision E 10/2015 McQuay Console Water Source Heat Pump WMH, WMG, WMK, WCH, WCG 015, 019 Vintage A Last Manufactured: 1993 To find your Daikin Applied parts distributor,
More informationKITS COMMON TO HEATING AND COOLING EQUIPMENT 504,652M 03/04. Supersedes 503,249M
2004 Lennox Industries Inc. Dallas, Texas KITS COMMON TO HEATING AND COOLING EQUIPMENT 504,652M 03/04 Supersedes 503,249M Litho U.S.A. COMPRESSOR REPLACEMENT KIT INSTALLATION INSTRUCTIONS FOR COMPRESSOR
More informationPARTS MANUAL. American Dish Service ADS CONVEYOR DISHWASHER MODELS: ADC-66 L-R/R-L EFFECTIVE: MAY, 2014
EFFECTIVE: MAY, 2014 ADS CONVEYOR DISHWASHER MODELS: ADC-66 L-R/R-L PARTS MANUAL 900 Blake Street Edwardsville, Kansas 66111 (913)422-3700 05/08 The American Dish Service part numbers contained in this
More informationParts Manual. Floor Type Electric Convection Steamer. Series: Classic Electric Boiler Base Steamer East 179 th Street Cleveland, Ohio 44110
Parts Manual Floor Type Electric Convection Steamer Series: Classic Electric Boiler Base Steamer 1333 East 179 th Street Cleveland, Ohio 44110 Phone: (216) 481-4900 1-800-338-2204 Fax: (216) 481-3782 www.clevelandrange.com
More informationDTW Works Master Specification Version 2006 Issued 2006/08/01 Section15621 Packaged Reciprocating Water Chillers Page 1 of 5
Issued 2006/08/01 Section15621 Packaged Reciprocating Water Chillers Page 1 of 5 PART 1 GENERAL 1.1 RELATED SECTIONS.1 Section 01330 Submittal Procedures..2 Section 01355 Waste Management and Disposal..3
More informationULTRA-SAFE Explosion-proof Duct Heaters
Standard Construction Heat Exchanger has copper tubes with integral aluminum fins. Each unit undergoes hydrostatic testing at 350 psig, five times the pressure relief valve setting of 70 psig. Heat Transfer
More informationRapide Gas Boilers BRG 80 BRG 120 BRG 200
Rapide Gas Boilers BRG 80 BRG 120 BRG 200 Spare Parts 9500-1006 Issue 10 Date Nov 94 Rapide Gas Boilers BRG 200 Spare Parts 9500-1007 Issue 10 Date Nov 94 9500-1101 Key Nº Description Part Nº 10
More informationInstallation, Operation, Maintenance and Service Instructions. Fryer Model: 130F
Installation, Operation, Maintenance and Service Instructions Fryer Model: 130F Star Manufacturing International 10 Sunnen Drive St. Louis, MO.63143-3800 Part Number: 2M-W478 Ph: 314-781-2777 Fax: 314-781-2714
More informationPart No Revised November / Instruction Manual Model #8150 AND #8151
Part No. 88359 Revised November 2003 8150 / 8151 Instruction Manual Model #8150 AND #8151 SAFETY PRECAUTIONS 8150 AND 8151 INSTALLATION FORWARD This manual covers the model # 8150 and 8151 front loading
More informationM50SL / M75SL Parts Manual
M50SL / M75SL Parts Manual American Dryer Corporation 88 Currant Road Fall River, MA 02720-4781 Telephone: (508) 678-9000 / Fax: (508) 678-9447 E-mail: techsupport@amdry.com www.amdry.com ADC Part No.
More informationStandard Duct Heaters Open Coil
HUA Slip-In and HUP Flanged Heaters The 80% Rule HEATREX recommends the heater should occupy at least 80% of the actual inside area of the duct, as shown in Figure 45. Only small amounts of air will bypass
More informationINDIRECT FIRED, SEMI-INSTANTANEOUS STEAM & BOILER WATER HEATER. Compact Design. High Recovery. Energy Efficient. Stainless Alloy Construction
INDIRECT FIRED, SEMI-INSTANTANEOUS STEAM & BOILER WATER HEATER Compact Design High Recovery Energy Efficient Stainless Alloy Construction Factory Packaged Integral Safety System ASME Constructed & Stamped
More informationMcQuay. Ceiling Concealed Horizontal Water Source Heat Pump. CCH, CCG, CCW 048, 060 Vintage A. Last Manufactured: 1995
Replacement Parts List No. 055236000 Revision B 06/2015 McQuay Ceiling Concealed Horizontal Water Source Heat Pump CCH, CCG, CCW 048, 060 Vintage A Last Manufactured: 1995 To find your Daikin Applied parts
More informationElectric Duct Heaters. IDHB & IDHC Series
Electric Duct Heaters IDHB & IDHC Series May 2014 1 Duct Heaters Greenheck has a complete line of configurable electric duct heaters that are perfectly suited to your HVAC application. Our CAPS configuration
More informationTSC & TSC-M Proofer/Oven
Illustrated Parts List BAKING CENTER BAKING CENTER TSC & TSC-M Proofer/Oven MODELS: TSC-6/8 TSC-6/8M TSC-/9 (Introduced February/009) TSC-/9M (Introduced January/0) This manual is Copyright 07 Duke Manufacturing
More informationB-14G. for series number with jm or j
B-G boilerless steamer REPLACEMENT PARTS LIST for series number with jm or j Effective june, 0 Superseding All Previous Parts Lists. The Company reserves the right to make substitution in the event that
More informationCleveland Range Inc. COMBINATION COOK TANK, CHILLER & SOUS VIDE PRODUCTION UNIT. Cleveland General Specifications. Cleveland Standard Features
TM MODEL: TJ-100-CC COMBINATION COOK TANK, CHILLER & SOUS VIDE PRODUCTION UNIT Cook/Chill Systems Cleveland General Specifications The capacity of the TurboJet is up to 100 gal. for pumpable (kettle produced)
More informationBarrier Washer. Parts. Refer to Page 3 for Model Numbers. BAR17P_
Barrier Washer Refer to Page 3 for Model Numbers Parts BAR17P_1300622 www.alliancelaundry.com Part No. 1300622R4 November 2014 Table of Contents Title Page Parts Ordering Information... 2 Serial Plate
More informationInstallation Instructions
Installation Instructions 6 KW and 11.5KW Basic Circulation Water Heater and Pump Application: The Basic Circulation Water Heater has been in use for nearly 50 years, and it is the most prevalent model
More informationTubular Industrial Process
Application Tempco Over-the-Side Immersion Heaters are specifically designed for heating fluids in tanks. Depending on the tank shape, size, accessibility and working area inside the tank, choose a round
More informationFlange Heaters - CX. Application. Corrosion. Watt Density. Passivation. Construction. Flange Heaters CX
Heaters - CX Heaters CX Application heaters are used to heat liquids or gases in tanks or in-line vessels. Safe and reliable service from the heater requires the correct selection of materials and heating
More informationParts List. Modular Crescent Cuber. Models KM-901MAJ KM-901MWJ KM-901MRJ/3. hoshizakiamerica.com
Parts List Modular Crescent Cuber Models KM-901MAJ KM-901MWJ KM-901MRJ/3 hoshizakiamerica.com Number: 71391 Issued: 10-23-2017 Revised: 6-8-2018 CONTENTS Auxiliary Codes... 3 Note About Ordering Parts...
More informationFES - Series Portable Electric Heaters. YES - Series Suspended Electric Heaters CONTENTS
FOSTORIA INDUSTRIES, INC. A DIVISION OF FES - Series Portable Electric Heaters YES - Series Suspended Electric Heaters (FES-1524-3E shown) IMPORTANT SAFETY INFORMATION INSIDE Serious injury or death possible.
More informationMcQuay. Incremental Packaged Terminal Air Conditioner. MQT Vintage B. Last Manufactured: 1994
Replacement Parts List No. 05708900 Revision C 06/205 McQuay Incremental Packaged Terminal Air Conditioner MQT 06-4 Vintage B Last Manufactured: 994 To find your Daikin Applied parts distributor, call
More informationMODEL DESCRIPTION PART NO.
Electric Parts List Food Warmers NOTE: Always include plate data specifications when ordering replacement parts. MODEL PART Aerohot, Heritage Knob for Infinite Switch 2164 Aerohot, Heritage Infinite Switch,
More informationFor more Parts Information:
For more Parts Information: https://manitowocfsg.sysonline.com/default.aspx TABLE OF CONTENTS Manitowoc Foodservice [Updated: Sep. 30, 2013] Manitowoc - Ice & Related Parts Catalog Ice Machine Q Series
More informationWATLOW IND. WATROD Modular Duct Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2
I&M NUMBER: 316-42-15-1 Page: 1 _ Pre Installation Check to make sure that heater received is the same as that ordered. Elements may come in contact with each other during shipment. Minor adjustments to
More informationMXn RACK OVEN SPARES MANUAL MACHINE NO.FG164
www.monoequip.com MXn RACK OVEN SPARES MANUAL MACHINE NO.FG164 When ordering spares please quote the machine serial number which can be found on the silver information plate of the machine and on the front
More informationMEIKO Undercounter Dish and Glass Washing Machine. Spare Parts List 208V/230V 1/3-PHASE 60 HZ
MEIKO Undercounter Dish and Glass Washing Machine Spare Parts List FV40.G 08V/0V /-PHASE 60 HZ Rev.. Updated: 0-8-04 CONTENTS. WASH PUMP PAGE. WASH SYSTEM PAGE. BOOSTER PUMP PAGE 7. SOLENOID / FILL VALVE
More informationAG Series Electric Heaters
AG Series Electric Heaters Installation, Operation and Maintenance Instructions Internal Auxililary Electric Heat 97B0005N03 Table of Contents Overview 3 Vertical Upflow Installation 4 Horizontal Installation
More informationOPERATING and MAINTENANCE INSTRUCTIONS Taco Bell Hot Cabinet Full Size Model: H137S27D1TB & H137S27D1LTB Half Size Model: H137S273D1TB & H137S273D1LTB
Rev. 1 (6/15) Page 1 of 5 Taco Bell Full Size Model: & H137S27D1LTB Half Size Model: & H137S273D1LTB H137S27D1LTB H137S273D1LTB Cabinet model number: Cabinet serial number: Authorized Service Agency: Ph:
More informationMODEL CMA-180UC SERVICE & PARTS MANUAL Rev 1.10
MODEL CMA-180UC SERVICE & PARTS MANUAL Rev 1.10 CMA DISHMACHINES 12700 KNOTT AVENUE GARDEN GROVE, CALIFORNIA 92841 800-854-6417 FAX 714-895-2141 www.cmadishmachines.com 0203 TABLE OF CONTENTS MODEL CMA-180UC
More informationMcQuay Climate Control Singer. Incremental. ES, RS, S 06, 09, 11, 14 Vintage B. Last Manufactured: 1991
Replacement Parts List No. 055203500 Revision G 05/206 McQuay Climate Control Singer Incremental ES, RS, S 06, 09,, 4 Vintage B Last Manufactured: 99 To find your Daikin Applied parts distributor, call
More informationSERVICE MANUAL. Bradford White ElectriFLEX HD (Heavy Duty) Commercial Electric Water Heater CEHD SERIES Immersion Thermostat Models
Bradford White ElectriFLEX HD (Heavy Duty) Commercial Electric Water Heater CEHD SERIES Immersion Thermostat Models SERVICE MANUAL Troubleshooting Guide and Instructions for Service (To be performed ONLY
More information961 SERIES CONFINED SPACE UNIT HEATER Horizontal or Vertical Mounting
961 SERIES CONFINED SPACE UNIT EATER orizontal or Vertical Mounting ATTENTION: Read carefully before attempting to install or operate Unit eater. FEATURES: Forced air electric unit heater available in:
More informationARM SERIES Switching Relays With Priority
Models ARM-2P ARM-3P ARM-4P ARM-6P AD-1 AD-4 ARM SERIES Switching Relays With Priority INSTALLATION, OPERATION & MAINTENANCE MANUAL ARM-2P ARM-4P AD-1 ARM-3P ARM-6P AD-4 Information and specifications
More informationKARMEL KING Instruction Manual Models: 2620 & 2621 (240 Volt) 2630 & 2631 (208 Volt) Part No Revised: February 2009
KARMEL KING Instruction Manual Models: 2620 & 2621 (240 Volt) 2630 & 2631 (208 Volt) Part No. 18736 Revised: February 2009 SAFETY PRECAUTIONS Mark 10, Karmel King (20 Gallon), and 2622 Rolling Truck Left
More informationGlass Washer. PERLICK Glass Washer NO ONE WORKS HARDER TO KEEP YOU COOKING. WHALEY FOODSERVICE REPAIRS ITEM PART NO. NO.
Glass Washer PERLICK Glass Washer 1 50567 Glasswasher Control 2 52536 Spray Arm Drive Motor 3 50445 Wash Pump 4 52528 Pump Motor Capacitor 5 52652-1 Water Inlet Valve 6 52669-1 Band Heater 7 52626A-B Rinse
More informationOPERATING AND MAINTENANCE MANUAL FOR PLATE HEAT EXCHANGER INDIRECT FIRED WATER HEATER. Electric Heater Company Base Model "BWXP"
OPERATING AND MAINTENANCE MANUAL FOR PLATE HEAT EXCHANGER INDIRECT FIRED WATER HEATER Electric Heater Company Base Model "BWXP" HUBBELL ELECTRIC HEATER COMPANY P.O. BOX 288 STRATFORD, CT 06615 PHONE: (203)
More informationTubular Industrial Process
Alternate NEMA 1 Housing Type 3N (for no thermostat) for 1", 1-1/4", 2" and 2-1/2" Screw Plug Heaters Screw Plug Immersion Heaters TYPE 4N (for no thermostat) for 1", 1-1/4", 2" and 2-1/2" Screw Plug Heaters
More informationINSTALLATION, OPERATION and MAINTENANCE MANUAL for Cres Cor 2kW RETHERMALIZER
Rev. 1 (1/16) Page 1 of 12 INSTALLATION, OPERATION and MAINTENANCE MANUAL for Cres Cor 2kW RETHERMALIZER REVOLUTION FOODS MODEL CO151027 Rev. 1 (1/16) Page 2 of 12 TABLE OF CONTENTS SUBJECT PAGE INSTALLATION
More information