1 Sentinel KalGUARD Water Treatment Equipment to Manage Hard Water Limescale Features & Benefits Provides whole system protection: Provides protection to water heaters Taps, showers and valves free of lime scale means fewer sites for hidden bacteria Heating systems are free of lime scale, reducing energy bills Safe to be included in drinking water, no need for complex plumbing to divert KalGUARD away from drinking water streams - meaning less complex installation Can be fitted to rising main, which is often smaller bore than the hot water distribution system, with resultant cost savings Metering system controls the operating parameters of the KalGUARD meaning it delivers the right amount of zinc for the intended application: Maximises life expectancy of the KalGUARD anode Provides the correct amount of protection for the intended system Complies with Part L Building Services Compliance Guide. WRAS approved. Overview Sentinel KalGUARD is an electrolytic scale inhibitor package for commercial hot water systems, an independently-proven, lowmaintenance way to protect a property against the damaging and expensive impact of limescale. Where a Sentinel KalGUARD replaces a brine water softener, a return on investment can be delivered usually within 12 months. The system is effective in all mains hard water areas found in the UK. KalGUARD is an environmentally friendly and non-polluting means of permanent water treatment. The anode is designed to be replaced after a 5-8 year service period on continuous dosing applications but can last up to years with intermittent usage. It will protect complete H&C systems by eliminating the formation of limescale encrustation, thereby ensuring continued maximum thermal efficiency and long major equipment life. This will also assist towards compliance with carbon emission regulations. The KalGUARD system does not use any chemicals or salt, nor any temporary electrical or electronic effects. Each system kit consists of the following components: Anode Unit the zinc alloy electrode unit Controller provides low voltage DC output to the anode (< 9 V DC) Flow Meter supplies water flow data to the controller Water filters and a pulse splitter unit are also available as optional accessories to the basic kit (see details below). Page 1 of 5
2 Schematic System Diagram The basic elements of the KalGUARD system are illustrated below (Fig.1). Anode Unit The KalGUARD anode is plumbed directly into the main water supply to the building. It is constructed from a copper body with solid brass fittings and is therefore very robust - a bright plated finish also ensures long lasting protection. The sizing is based on individual site requirements and KalGUARD kits are available in sizes 22, 28, 35, 42, 54, 67, 76 and 108 mm, providing complete coverage. Dimensions, flow rates and other technical data can be found below in the Specification Table. Important Note: The use of delayed action ball valves, or other similar water level control systems, is strongly recommended in order to avoid trickle flow conditions which can potentially compromise the efficacy of a KalGUARD installation. Controllers Mk 1 Mk 2 Alternative controllers are supplied with the KalGUARD system, depending on the anode sizing. The Mk 1 and Mk 2 controllers both have BMS connection capability and the facility to identify / alert regarding any potential faults with the installation. The Mk 2 unit is supplied with the smaller KalGUARDs from 22 through to 54 mm, whilst the original Mk 1 controller is supplied with KalGUARDs 67, 76 and 108 mm. Page 2 of 5
3 The units are both mains powered (240 VAC 50 Hz Single Phase) and designed to be wall mounted near to the KalGUARD system. A special anode connection cable and full instructions are supplied with each unit. Refer to the Specification Table for details of dimensions and other technical data. Water Meter Each KalGUARD kit is supplied with a water flow meter, providing a digital signal designed to regulate the output of the KalGUARD controller. The water flow meters feature a dry dial design and are constructed with brass bodies. Dimensions, flow rates and other technical data can be found below in the Specification Table. Filter Filters are recommended in instances where there is a risk of debris entering the water supply, which is a common problem on new build installations. Manual disc filters are supplied by Sentinel as accessories to the standard KalGUARD kits. The filters are available in a range of sizes to suit the installation. All units are manufactured from robust engineering plastics to ensure that they remain corrosion free. Durable disc filter elements are used across the range - they are easily cleaned and can be immediately reinstalled after cleaning. Dimensions, weights and other technical data can be found below in the Specification Table. KalGUARD Pulse Splitter The KalGUARD Pulse Splitter is an optional accessory to the Sentinel KalGUARD system. It is designed to take an electrical feed from the KalGUARD water meter and split the signal into two separate, isolated outputs. One of the outputs is fed into the KalGUARD controller and the second to supply a separate Building Management System (BMS) in order to monitor water flow rate or water usage. It can be used with any size of KalGUARD anode and either version of controller. The Pulse Splitter can be directly mounted on standard DIN rail. See Specification Table for further details. Page 3 of 5
4 Anode Units Product Code KalGUARD Specification Table Diameter (Main Body) Weight (kg) Flow (l/m) Flow Connection KALG /4" BSP Female 0.15 KALG " BSP Female 0.13 KALG / 4" BSP Female 0.23 KALG / 2" BSP Female 0.26 KALG " BSP Female 0.26 KALG / 2" 8 bolt DIN/ANSI Flange 0.20 KALG " 8 bolt DIN/ANSI Flange 0.23 KALG " 8 bolt DIN/ANSI Flange 0.20 Flow Water Meters KG Size Water Meters (in) mm Width Height Weight (kg) Connections Qmax Qn Qmin (l/h) Max Pres. (bar) 22 3/4" /4" BSP Male " " BSP Male / 4" / 4" BSP Male / 2" / 2" BSP Male " " BSP Male / 2" PN16 Flanges PN16 Flanges PN16 Flanges K Value (litre) Qn Qmax = Qn = Max flow (short period) nominal flow Filters For Width Height Weight (kg) Connection Diam. Average Flow 55u 1" Short 22 mm KG " Super 28 mm KG /2" Super mm KG " Leader 42 & 54 mm KG " Leader 67 mm KG " Leader 76 mm KG " Leader 108 mm KG Flow Page 4 of 5
5 Controllers Version For Width Height Depth Display Power Supply BMS Connectivity IP Rating Mk 1 67, 76, 108 mm KG LCD 240 V AC Fault Alert, Optional Pulse Splitter 65 Mk 2 22, 28, 35, 42 & 54 mm KG OLED 240 V AC Fault Alert, Remote Switching (on/off), Optional Pulse Splitter 65 Page 5 of 5
The NEW advanced electrolytic scale inhibitor with intelligent LED monitoring technology from Sentinel
The NEW advanced electrolytic scale inhibitor with intelligent LED monitoring technology from Sentinel 1. Proven best in class scale control 2. Unique LED shows ScalePro is working effectively 3. One installation
More informationCommercial product range
Commercial product range 1 Commercial Installer Brochure A4_COVER.indd 1 21/09/2017 15:21 Whether it s marketing leading filters or award-winning chemicals, we design and manufacture effective solutions
More informationPOWERFLOW Series. Unvented Electric Storage Water Heaters. Installation & Operating Instructions Manual
POWERFLOW Series Unvented Electric Storage Water Heaters Installation & Operating Instructions Manual These Instructions must be left with the user after installation. Version 3.0 June 2009 Hyco POWERFLOW
More informationPowerflow Unvented water heater
Product Instruction Manual Powerflow Unvented water heater 30, 50 and 90 litres v15.6/5 Thank you for purchasing a Powerflow series unvented electric water heater. The Powerflow is suitable for hand washing
More informationProduct Guide Immersion Heaters & Accessories
Over 20 years experience in manufacturing, product development and distribution in the plumbing & heating industries. Product Guide Immersion Heaters & Accessories See www.teslauk.com for more products
More informationVented systems explained Performance without compromise Vented System (Gravity Fed) Positive Head Systems
Vented systems explained Vented System (Gravity Fed) Typically used in older properties, this indirect system uses the mains water supply to feed a cold water storage tank, usually located in the roof
More informationFor commercial & industrial systems. Large volume dirt collection capacity
For commercial & industrial systems Large volume dirt collection capacity Heating & Cooling System Protection Maintaining system efficiency and reliability in larger properties is a major challenge for
More information1 Dimensions Installation Mains/boosted cold water inlet Connection to the system Drain Dimension for fixing 6
Electronic Filling Device (EFD) Installation and Maintenance Instructions Contents 1 Dimensions 3 1.1 Installation 4 1.1 Mains/boosted cold water inlet 4 1.2 Connection to the system 5 1.3 Drain 5 1.4
More informationProduct Guide Immersion Heaters & Accessories
Over 20 years experience in manufacturing, product development and distribution in the plumbing & heating industries. Product Guide Immersion Heaters & Accessories See www.teslauk.com for more products
More information9.0 Systems For Domestic Water Installations
9.0 Systems For Domestic Water Installations 9.0.1Equipment Catalogue 2009 9.0.1 Proportional Flow Dosing System For Liquid Dosing turbodos, DULCODOS metering systems protect pipework, fittings, and devices
More informationQUANTURA DISHWASH DOSING SYSTEMS. revolutionary dispensing solutions
QUANTURA DISHWASH DOSING SYSTEMS revolutionary dispensing solutions QUANTURA BRIGHTWELL DISPENSERS NEW RANGE OF DISHWASH DOSING SYSTEMS Reliable and efficient chemical dosing systems ensure that commercial
More informationWARNING NOTICE. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi. IMPORTANT
Bradley 1C Individual Built-In Wall Shower with Concealed Supplies Table of Contents Pre-Installation Information... 2 Rough-In... 3 Make Electrical Connections... 4 Adjusting the Module... 4 Complete
More informationHamworthy. Dorchester DR-SA & DR-SE Fully Automatic and Permanent Pilot Direct Gas-Fired Storage Water Heaters. Exceeds Minimum Requirements
Exceeds Minimum Requirements Hamworthy Dorchester DR-SA & DR-SE Fully Automatic and Permanent Pilot Direct Gas-Fired Storage Water Heaters 18.9 kw to 20.1 kw, Natural Gas or LPG Continuous outputs 369
More informationAQUABION Galvanic water treatment for limescale & corrosion Frequently Asked Questions (FAQ s) June 2018
AQUABION Galvanic water treatment for limescale & corrosion Frequently Asked Questions (FAQ s) June 2018 Q 1: What is AQUABION? A: AQUABION is a treatment for limescale in water systems consisting of a
More informationHotflo. Unvented point of use hot water
Unvented point of use hot water We developed the range for people who need a hot water supply for two to three basins or sinks. Flexible siting is a key design feature that we insisted upon because it
More informationPRODUCT GUIDE A WATER HE ATER S ULTIMATE DEFENSE 12 YEAR WARRANTY ION POLARIZATION SCALE REDUCTION SYSTEM
PRODUCT GUIDE ION POLARIZATION REDUCTION SYSTEM 12 YEAR WARRANTY Prevents lime-scale buildup on water heater elements No maintenance, No power or filter replacements Eliminates up to 75% of scale deposits
More informationPRODUCT GUIDE A WATER HEATER S ULTIMATE DEFENSE 12 YEAR WARRANTY ION POLARIZATION SCALE REDUCTION SYSTEM
PRODUCT GUIDE ION POLARIZATION SCALE REDUCTION SYSTEM 12 YEAR WARRANTY Prevents lime-scale buildup on water heater elements No maintenance, No power or filter replacements Eliminates up to 75% of scale
More informationmarine horticulture recycling
Stuart offers a range of solutions for water transfer, pressure boosting and submersible pump applications. Together with water conditioning, pressurisation units and a range of high quality unvented hot
More informationTechnical and Installation manual All Models
WATER CONTROL setting the standards Technical and Installation manual All Models CONTENTS CONTENTS Section 1 Introduction 1-1 Introduction ---------------------------------------------- 2 1-2 System Layout
More informationINTRODUCTION STORAGE PRIOR TO INSTALLATION. Expansion Vessel Hose. Part No High Flow Rate Inlet Control Set. Part No.
INTRODUCTION The Worcester Greenskies cylinder is a Stainless Steel Unvented Twin Coil Storage vessel specifically designed to be installed in conjunction with the Worcester Greenskies solar package. Should
More informationBalba. Technologies Limited. An Introduction to Side Stream Filtration And the Balba Viking Product Range
Balba Technologies Limited An Introduction to Side Stream Filtration And the Balba Viking Product Range Website www.balbatech.com 1 Index An introduction to side stream filtration 1 Filtration Systems
More informationCONTENTS. Page. Contents 1. Introduction, features and benefits 2. PART ONE Overview of the softening process 4-5
CONTENTS Page Contents 1 Introduction, features and benefits 2 PART ONE Overview of the softening process Installation and operating considerations Installation layout PART TWO Installing your water softener
More informationMains Pressure Hot Water from an existing vented copper cylinder... Allows the cold water tank to be removed, freeing loft space.
DPS Hi-Flow Mains Pressure Hot Water from an existing vented copper cylinder... Converts an existing hot water cylinder to provide potable mains pressure hot water at high flow rates to all existing outlets.
More informationEW447-EW452 Series Mechanical Heat Meters FOR HEATING AND COOLING APPLICATIONS
Design Hydronic meters of the EW447-452 Series consist of: Electronic energy integrator with fixed cable connection to the volume measuring component, supply and return temperature probe Mechanical volume
More informationUNIQ HEAT BATTERIES REFERENCE MANUAL_V2.2. Version: 2018_07_19_v2.2
UNIQ HEAT BATTERIES REFERENCE MANUAL_V2.2 Version: 2018_07_19_v2.2 Abstract This is a quick reference guide for selecting the UniQ range of heat batteries for the required application. For designing a
More informationLEAKSTOPPER RANGE Multizone water leak detection systems
LEAKSTOPPER RANGE Multizone water leak detection systems WHAT DOES THE PRODUCT DO? The LeakStopper detects water leaks and instantly triggers an alarm to warn you. It is capable of monitoring between 2
More informationTHE NON-ELECTRIC MINIMAX M2 BLOCK SALT SOFTENER. Powerful, Reliable, Efficient. >>>
THE NON-ELECTRIC MINIMAX M2 BLOCK SALT SOFTENER Powerful, Reliable, Efficient. >>> The Benefits... What are the benefits of softened water? Completely softened water from Minimax offers many exceptional
More informationEliminator TotalGuard Installation Manual
Eliminator TotalGuard Installation Manual Central Heating Filter Version 2 January 2016 IMPORTANT Please retain these instructions for reference during servicing Page 1 Eliminator TotalGuard Instructions
More informationUNVENTED WATER HEATERS. Water Heater Display Stand
Water Heater Display Stand 26 28 5 L & 10 L UNVENTED WATER HEATERS 30 PLUMBING INSTRUCTIONS EXPANSION VESSELS 32 15 L & 30 L UNVENTED WATER HEATERS 34 50 L & 100 L UNVENTED WATER HEATERS 27 5 Litre and
More informationPlease take time to carefully read through these guidelines before using your Kamco pump.
The Kamco CLEARFLOW CF90 : QUANTUM pump is a purpose built unit for Power Flushing central heating systems, designed to cure circulation and boiler noise problems caused by the accumulation of sludge,
More informationPlease take time to carefully read through these guidelines before using your Kamco pump.
The Kamco CLEARFLOW CF30 CLASSIC pump is a purpose built unit for Power Flushing central heating systems, designed to cure circulation and boiler noise problems caused by the accumulation of sludge, corrosion
More informationINSTALLATION INSTRUCTION
INSTALLATION INSTRUCTION Thermostatic Mixer Shower System NOTICE The instruction manual includes part lists, installation instructions, usage of thermostatic and suitable inlet system. Make sure the installation
More informationPlease take time to carefully read through these guidelines before using your Kamco pump.
The Kamco CLEARFLOW CF190 / CF230 DDV pumps are purpose built units for Power Flushing central heating systems, designed to cure circulation and boiler noise problems caused by the accumulation of sludge,
More informationß ß ß ß ß ß ß. Group application electronic temperature controller. Suitable for multiple shower and washing applications
rada 32rmx electronic temperature controller Group application electronic temperature controller Suitable for multiple shower and washing applications Electronic LED temperature display Low voltage (12
More informationUnvented Electric Water Heater 10/15 litre Undersink
Unvented Electric Water Heater 10/15 litre Undersink Fitting Instructions and User Guide 1 CONTENTS SECTION PAGE 1.0 INTRODUCTION 2 2.0 TECHNICAL SPECIFICATION 3 3.0 INSTALLATION 4 4.0 COMMISSIONING 9
More informationEmission Monitoring System
Advance Cemas-FTIR Multi-component Emission Monitoring System System Description 30/23-200-1 EN System Overview Measurement principle The Advance Cemas FTIR is a multi-component emission monitoring system
More informationCistern-fed water heating
Cistern-fed water heating 95 900 883 Issue 1 Introduction 03 Heatrae Sadia has built an unrivalled reputation for developing, manufacturing and marketing the highest quality products. By offering the widest
More informationUPONOR Ltd. Specification for UPONOR Q&E PEX Shrinkfit Plumbing Systems
UPONOR Ltd Specification for UPONOR Q&E PEX Shrinkfit Plumbing Systems Reference Page(s) UPONOR Q&E PEX 2 Operating Conditions 2 Pipe Properties 2 Fittings Range 3 Radiator Heating Systems 3 H&C Water
More informationBrazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)
Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16) Description XB06 The XB is a brazed plate heat exchanger designed for use with district heating systems (i.e. air conditioning,
More informationBath Shower Mixer
86004490 Bath Shower Mixer Installation and operating instructions The showerhead and hose supplied with this product are a safety critical part of your shower. Failure to use genuine Triton parts may
More informationBWT WS Range Water Softener
WS Cover.pdf 1 02/01/2014 13:29 Fitting and operating instructions EN BWT WS Range Water Softener BWT WS Range /09-2012 BWT UK Limited Changes of technical details are reserved Important notice: Always
More informationTHERMOSTATIC SHOWER CONCEALED VALVE - TWIN WITH DIVERTER & TRIPLE WITH DIVERTER
THERMOSTATIC SHOWER CONCEALED VALVE - TWIN & TRIPLE INSTALLATION INSTRUCTIONS INTRODUCTION This thermostatic valve is suitable for use with all water systems with an operating pressure of 2-5 bar (beyond
More informationProduct Catalog and Technical Specifications for DCW-Units
Product Catalog and Technical Specifications for DCW-Units We provide cost effective, safe, environmentally responsible solutions to bacterial control in the food and water industries. Registrations: DE:
More informationPLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL
PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION SOLARCYL IM/SC INSTALLATION MANUAL This manual gives detailed advice for installation and should be read carefully prior to fitting any unvented
More informationTECHNICAL SPECIFICATIONS - CW-80T-TWIN AUSTRALIAN, EUROPEAN, SOUTH AFRICAN & UK
GENERAL Climate Wizard coolers operate with a high ratio of energy efficiency and deliver cool fresh air at extremely low energy cost. The CW-80T-TWIN is characterized by having no additional moisture
More informationOwners Manual For The Rainmaster Water Recycling System
Owners Manual For The Rainmaster Water Recycling System Owners Manual.indd 1 4/8/05 8:58:36 AM Rain Master Water Recycling System Welcome! Thank you for purchasing a Rainmaster Water Recycling System.
More informationPowerstock Storage Tank
Powerstock Storage Tank Models ST300, ST500, ST750 & ST1000 INSTALLATION, COMMISSIONING AND SERVICING INSTRUCTIONS THE POWERSTOCK STORAGE TANK IS INTENDED FOR USE AS A COMMERCIAL APPLIANCE. PUBLICATION
More informationCITY OPEN - CITY BOX from 25 to 35 kw
CITY OPEN - CITY BOX from 25 to 35 kw Technology and automotive innovation, resistance to sun, rain, frost and salt IPX5-10 C Born to resist IPX5-10 C City Open - City Box STAINLESS STEEL COMBUSTION GROUP
More informationInstallation and User Instructions Aquaheat Unvented Water Heaters Models: AH30H
Installation and User Instructions Aquaheat Unvented Water Heaters Models: AH30H Please read and understand these instructions before starting work. Please leave this leaflet with the user following installation
More informationInstallation, Operation and Maintenance Manual for the Potable Water System Model: PWS-01 (380 VAC Suppy x 24 VDC Controls)
Installation, Operation and Maintenance Manual for the Potable Water System Model: PWS-01 (380 VAC Suppy x 24 VDC Controls) (Part No: KI40008AB) A part of (Intentionally Blank) Approval Sheet Divex Advitium
More information1 VICTRIX ZEUS Superior kw I features
Wall-hung condensing VICTRIX ZEUS Superior kw I is the new range of wall-hung condensing boilers with 54 litre stainless steel storage tank available in two versions with nominal heat output of 26 kw and
More informationLEAKSTOPPER 1 Single zone water leak detection system
LEAKSTOPPER 1 Single zone water leak detection system WHAT DOES THE PRODUCT DO? The LeakStopper 1 detects the presence of water in environments where it is not supposed to be. Should water be detected
More informationStokvis R600 LMS IP Water Heater Gas-Fired Floor Standing Condensing
Stokvis R600 LMS IP Water Heater Gas-Fired Floor Standing Condensing Water Heater Supplement STOKVIS ENERGY SYSTEMS 96R Walton Road East Molesey Surrey KT8 0DL Tel: 020 8783 3050 / 0870 7707747 Fax: 020
More informationInstallation Information User Manual
1-5 Anzac Avenue Smeaton Grange NSW 2567 is a division of BioSeptic Pty Ltd - ABN 95 056 461 226 Ph: 02 4629 6633 Fax: 02 4629 6677 Email: sales@sydneywatertanks.com.au Web: www.sydneywatertanks.com.au
More informationHerz York Direct Heat Interface Unit
www.herzvalves.com Herz York Direct Heat Interface Unit The Modern Solution for Apartment Heating and Domestic Hot Water Services General Description The Herz York Direct HIU is suitable for all community
More informationTABLE OF CONTENTS TECHNICAL DOCUMENTATION 03. Technical Data Electrical Details Connection Details Dimensions Standing Losses
INSPIRED H I G H H O T EF F ICIENCY E F F I C I E N C Y W A T E R S Y S T E M S E XT REME HIGH EFFICIENCY HO T W AT ER SY ST EMS w i th I N JECT I O N DYN A M I C S T ECHN I CAL DO CUME N TA T I O N I
More informationHazardous Location LED Pivoting Light - C1D2 - Dimmable - Modbus TCP/IP Network - Meets USCG Specs
Hazardous Location LED Pivoting Light - C1D2 - Dimmable - Modbus TCP/IP Network - Meets USCG Specs Part #: HALP-ANC-48-2L-LED-D-V2 Page: 1 Made in the USA The Larson Electronics HALP-ANC-48-2L-LED-D-V2
More informationHodge Clemco Ltd. MJC Mini Cartridge Filters Owners Manual. TSOM 556 Date of issue 13/07/04. Hodge Clemco Ltd
1 MJC Mini Cartridge Filters Owners Manual TSOM 556 Date of Issue: 13.07.04 Orgreave Drive, Sheffield South Yorkshire. S13 9NR Tel:0114 254 0600 Fax: 0114 2540250 Email:sales@hodgeclemco.co.uk www.hodgeclemco.co.uk
More informationHYBRID ADIABATIC Cooling System
Blending Conveying Drying Process Cooling Heat Transfer Size Reduction HYBRID ADIABATIC Cooling System Water & Energy Savings Low Maintenance Improved Health & Safety Hybrid design combines dry cooler
More informationBroag Pressurisation equipment
Broag Pressurisation equipment Compact wall mounted and free standing pressurisation units, utilising the latest microprocessor control. For use on sealed heating and cooling systems, offering accurate
More informationECONOBOOST EB II & EB III Compact Water Booster
ECONOBOOST EB II & EB III Compact Water Booster The Stokvis EB II twin pump & EB III triple pump cold water booster units meet today s need for compact, reliable, high performance equipment with modest
More information6800 Design Envelope Booster. Technical overview
6800 Design Envelope Technical File No: 100.30in Date: may 26, 2014 Supersedes: 100.30in Date: march 17, 2014 contents 1. Product introduction 4 Summary 4 Background 4 Benefits 4 2. Product data 5 Nomenclature
More informationIC-45AV Vertical Clean Centrifuge
IC-45AV Vertical Clean Centrifuge Solid/Liquid High G Force Centrifuge Separating Difficult Solids IC45AV Centrifuge Vertical Clean The Interfil IC45-AV is high speed Centrifuge suitable for any type of
More informationDirect reading flowmeters type RM
FLOWMETERS 7 Direct reading flowmeters type RM The direct reading flowmeters type RM are flow measuring devices suitable for small flows of liquid and gaseous fluids. The measure cone is got directly from
More informationHigh Pressure Conductivity Monitor
Product Data Sheet PDS 71-EDS880/1/rev.A August 2006 Model EDS880/1 High Pressure Conductivity Monitor COMPLETE SYSTEM FOR THE DETERMINATION OF CONDUCTIVITY IN HIGH PRESSURE SYSTEMS SENSOR INSTALLS DIRECTLY
More informationUnvented Water Heaters. September Aqualine. Unvented Electric Water Heating
Aqualine Unvented Electric Water Heating Unvented Water Heaters September 2015 Unvented Water Heaters Aqualine Unvented Water Heaters Commercial Unvented Water Heaters with TMV2 Thermostatic Blending Valve
More informationPLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL
PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION 0 RD 0 RI 0000-06 IM/ IM/a INSTALLATION MANUAL This manual gives detailed advice for installation and should be read carefully prior to fitting
More information541D19 SERIES. Technical Manual. A Division of Aquion Partners L.P.
541D19 SERIES Technical Manual A Division of Aquion Partners L.P. Table of Contents Introduction... Page 1 Technical Specifications... Page 2 Flow Diagrams... Page 3 Injector & Flow Control Selection Injector...
More informationCORREX MP Anode with external voltage source. Installation & Operation Manual
CORREX MP Anode with external voltage source Installation & Operation Manual Contents 1 Safety instructions... 3 2 Use in accordance with designated purpose... 5 3 Function... 5 4 Volume of the delivery...
More informationPWC 1800 PureWaterCooler SERVICE MANUAL. for. PureWaterCooler by Vertex Model PWC P/N man Copyright 2011 Vertex Water Products
SERVICE MANUAL for by Vertex Model PWC-1800 P/N man-7011 Table of Contents 1. Introduction 2. Cooler Set-up 3. Remove Top Cover 4. Remove/Replace Float 5. Remove/Replace Hot Tank 6. Dispensing Solenoid
More informationCT range. of shower, bathroom and whole house pumps
CT range of shower, bathroom and whole house pumps 2 Salamander Pumps is one of the UK s leading manufacturers of shower and domestic water pumps. Innovation is used throughout the organisation to create
More informationMW & EW 10 & 15 Litre Unvented Water Heaters HANDBOOK. IMPORTANT: This booklet should be given to the customer after installation and demonstration.
MW & EW 10 & 15 Litre Unvented Water Heaters HANDBOOK IMPORTANT: This booklet should be given to the customer after installation and demonstration. Description of water heater 1) Hot water outlet 2) Temperature
More informationCROWN WATER HEATERS CPU10 - CPU15 CPOS10 - CPOS15
CROWN WATER HEATERS CPU10 - CPU15 CPOS10 - CPOS15 COMPACT PLUS 10 and 15 Litre Unvented Under and Over Sink Water Heater INSTALLATION AND USER GUIDE 1 DIMENSIONS 10L - 250mm 15L - 310mm 100mm 80mm 410mm
More informationTECHNICAL SPECIFICATIONS - CW-80T AUSTRALIAN, EUROPEAN, SOUTH AFRICAN & UK
GENERAL Climate Wizard coolers operate with a high ratio of energy efficiency and deliver cool fresh air at extremely low energy cost. The CW-80T is characterized by having no additional moisture added
More informationMiscellaneous. TMV3 Mixing Valves. TMV3 Thermostatic Mixing Valves. Specifications. Temperature Readout. Features include:
TMV3 Mixing Valves TMV3 mixing valve inside DVS shower tower 2in1TMV3 thermostatic mixing valve TMV3 mixing valve supplying mixed water to DVS tap TMV3 Thermostatic Mixing Valves A highly advanced TMV3
More informationTaps, Shower & Flush Valve Range
CI/SfB (74) X Taps, Shower & Flush Valve Range First Edition DOLPHIN Washrooms worth experiencing You can tell how much a company cares about its customers by inspecting its washrooms Copyright Bell-Chem
More informationInstaller & User Guide Effective February 2013
Model No. MONARCH WATER Installer & User Guide Effective February 2013 For Monarch Scaleout Suppliers to H.M. the Queens Estate at Sandringham Monarch Water Ltd. Halesworth Road Bramfield IP19 9HP T 01986
More informationAIRE. Thermostatic bath shower mixer. Installation and Operating Instructions INSTALLERS PLEASE NOTE THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER
AIRE Thermostatic bath shower mixer Installation and Operating Instructions INSTALLERS PLEASE NOTE THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER 2180427C October 2005 CONTENTS Page Introduction 1 Safety
More informationWater Detection Controllers
Page 1 of 5 Water Detection Controllers Features: Benefit: LED Status of leak status VFC output Audible alarm Auto or manual reset alarm output Uses an isolated AC signal which prevents oxidation or erosion
More information24-28 kw Conventional Combi Gas Boiler. Lawa / LawaPlus
24-28 kw Conventional Combi Gas Boiler Lawa / LawaPlus Conventional Combi Gas Boilers Warmhaus wall-hung gas combi boilers Lawa and LawaPlus, with the advantage of its width as 288mm, are easily fit to
More informationBOILER HOUSE PRODUCTS GMS
GMS BOILER HOUSE PRODUCTS Contents Page 2 Introduction 3 Condensate Pumpsets 6 Blowdown Vessels 8 Boiler Feed Tanks Page 10 Chemical Dosing Pots 11 Vent Heads 11 De-Aerator Heads Introduction to Boiler
More informationWater Leak Detector - Four Zone with open/short-circuit detection. Product overview
Water Leak Detector - Four Zone with open/short-circuit detection Product overview The AX-WLDF is a four zone water leak detection module with open or short circuit sensor cable detection. The module must
More informationInstallation & Technical Guide. Domestic & Commercial.
Installation & Technical Guide Domestic & Commercial www.challisbooster.com www.challisboosterplus.com Installation and Technical Guide Domestic and Commercial Challis Water Controls Europower House, Lower
More information2020c WATER SOFTENER INSTALLATION INSTRUCTIONS. visit
00c WATER SOFTENER INSTALLATION INSTRUCTIONS visit www.kinetico.co.uk Safety Information Read all steps, guides and rules carefully before installing and using the Kinetico softener. Check your local building
More informationSAN JUAN FRESH WATER COOLING SYSTEMS
SAN JUAN FRESH WATER COOLING SYSTEMS 4.3-5.7 GI VOLVO Block Only Cooling, Mounted Off Engine Kit #V-111 Installation Instructions San Juan Engineering Heat Exchangers provide thermostatically controlled
More informationPRICE BID. UNIT QTY Rate in Figure Rate in words Amount DESCRIPTION OF ITEM D: FIRE PROTECTION SYSTEM
ANNEXUREIII D: FIRE PROTECTION SYSTEM SECTION ADDRESSABLE FIRE DETECTION AND ALARM SYSTEM Supply, Installation, testing and commissioning of Analogue Addressable Fire Alarm Control panel with battery backup
More informationADVANCE STAINLESS STEEL UNVENTED HOT WATER SYSTEMS
ISSUE 2 DECEMBER 2013 INSTALLATION AND USER GUIDE ADVANCE STAINLESS STEEL UNVENTED HOT WATER SYSTEMS FOR GAS, OIL, ELECTRIC SOLAR AND HEAT PUMP SYSTEMS ADVANCE APPLIANCES LTD PLEASE RETAIN AND ENSURE SERVICE
More informationProMinent ProMus Hydraulic Diaphragm Metering Pumps
ProMinent ProMus ProMinent ProMus Description: The ProMus is a motor driven metering pump with a hydraulically actuated diaphragm. The drive case and the hydraulic unit are filled with a liquid that functions
More informationESi CONTROLS BROCHURE LANDSCAPE V5.indd 1 14/08/ :31
ESi CONTROLS BROCHURE LANDSCAPE V5.indd 1 14/08/2014 18:31 The ESi family of programmers are a feature packed range, offering flexibility and reliability for use in any domestic heating and hot water installations.
More informationSECTION GENERAL-SERVICE COMPRESSED-AIR SYSTEMS
PART 1 GENERAL 1.01 SECTION INCLUDES A. Pipe and Pipe Fittings. B. Air compressor. C. Air receiver and accessories. D. Aftercooler. E. Refrigerated air dryer. F. Pressure reducing station. 1.02 RELATED
More informationInstaller & User Guide Effective January 2017
Model No. MONARCH WATER Installer & User Guide Effective January 2017 For Monarch Scaleout Suppliers to H.M. the Queens Estate at Sandringham Monarch Water Ltd. Halesworth Road Bramfield IP19 9HP T 01986
More informationWASHROOM. Solutions Super fast, super efficient... UK market leaders in washroom solutions for over 45 years.
WASHROOM Solutions Super fast, super efficient... UK market leaders in washroom solutions for over 45 years. Choose the right product for your application We like to help customers every step of the way,
More informationVacuum generators VADM/VADMI
Key features Product overview Vacuum generators All Festo vacuum generators have a single-stage design and operate according to the Venturi principle. The product series described below have been designed
More informationHORNE 15 and 20 thermostatic mixing valve specification manual 2009
HORNE 15 and 20 thermostatic mixing valve specification manual 2009 contents HORNE introduction 1-4 history 1 why TMVs? 3 why HORNE? 4 HORNE HORNE 15 TMV 5 4th connection 6 HORNE HORNE 20 TMV 7 HORNE appendix
More informationWater Softener Installation Guide Effective for all Softeners from our Range
Water Softener Installation Guide Effective for all Softeners from our Range Planning Your Installation Always observe the water byelaws. Ensure there is only one rising main, that you have allowed space
More informationNOT EVERYTHING IN LIFE IS COMPLICATED.
NOT EVERYTHING IN LIFE IS COMPLICATED. SCALEMASTER SOFTLINE 150 INSTALLATION & OPERATING PROCEDURES OWNERS MANUAL SCALEMASTER A Division of DAW Enterprises Ltd Emerald Way, Stone Business Park, Stone,
More informationADVANCE ECB ELECTRIC COMBINATION BOILER
ISSUE ISSUE 45 0115 0317 INSTALLATION AND USER GUIDE ADVANCE ECB ELECTRIC COMBINATION BOILER ADVANCE APPLIANCES LTD HOUSEHOLDER - PLEASE RETAIN AND ENSURE SERVICE RECORDS ARE KEPT UP TO DATE 1 SCHEMATIC
More informationTOSHIBA AIR CONDITIONING
Introduction The following specification describes the Toshiba Estia Air to Water Heat Pump system(s) to be installed at the site below: (ADD SITE NAME) The system(s) shall consist of the following components.
More informationSERVICE MANUAL. WS-55 Hobart Compact Water Softeners Installation Instructions - NOTICE - WS-55
SERVICE MANUAL WS-55 Hobart Compact Water Softeners Installation Instructions WS-55 - NOTICE - This Manual is prepared for the use of trained Hobart Service Technicians and should not be used by those
More informationOptimal work climate with open doors. Industrial air curtains Model IndAC
Optimal work climate with open doors Industrial air curtains Model IndAC Industrial air curtain Optimal work climate During loading and unloading the door remains open, without the indoor climate being
More information