Brazed heat exchanger, XB

Size: px
Start display at page:

Download "Brazed heat exchanger, XB"

Transcription

1 Description / application The X is a brazed plate heat exchanger designed for use with district heating systems (i.e. air conditioning, heating, domestic hot water). X brazed plate heat exchangers are made with several differently sized heat exchange plates. pprovals: C certificate according (PD) 97/23/C GOST/ Russia SVGW/Switzerland V/Denmark Main data: Min. temperature 10 C Max. temperature +180 C Max. working pressure 25 bar Circulation water / glycolic water up to 50% Connection size DN (threaded or flanged) DHSMT/I VD.K.6.02 Danfoss 11/2007

2 Ordering xplanation, X type X 10L 1 10 Number of plates Pass of the heat exchanger 1 = 1pass 2 = 2pass Plate type Plate size = razed heat exchanger The heat exchanger can consist of plates type L or plates type H. The H type plate has larger herring bone angle than the L type plate. H type plate fits better for certain temperatures than L type. H type heat exchangers have better heating capacity, but they also have higher pressure loss. The plate set can also be a combination of these two types. If every other plate is Htype plate and every other plate is Ltype plate, the combination is called type M. Plate types H M L L H L L type H type H M type The same principal difference can be obtained with other plate patterns as well. 1pass brazed heat exchangers type X H L Type X 041 X 06L1 X 06H1 X 101 X 201 X 241 X 301 X 361 X 401 Connection No of plates, n Thread Thread Thread Thread Thread Thread Thread Thread Thread G ¾ G ¾ G ¾ G 1 G 1 G ¾ (G 1 )¹) G 1 G 1 G for number of plates n 50 2 VD.K.6.02 Danfoss 11/2007 DHSMT/I

3 Ordering, continued 1pass brazed heat exchangers type X Type X 51H1 X 51L1 * X 51H1 S * X 51H1 S * X 51L1 S * X 51L1 S X 601 2) * X 601 S X 70L1 2) X 70M1 2) X 70H1 2) Connection No of plates, n Thread Thread Thread lange Thread lange lange lange lange lange lange G2 G2 G2 DN50 G2 DN50 DN 65 DN 65 DN DN DN 65/100 65/100 65/ primary side / secondary side 2) delivered with mounting brackets ex factory * Special versions; S This version includes 3 supporting bolts in the front and in the back, M12x20 2pass brazed heat exchangers type X Type X 042 X 102 X 202 X 302 X 51H2 X 51L2 Connection No of plates, n Thread Thread Thread Thread Thread Thread G ¾ G 1 G 1 G 1 G 2 G 2 20/ / / / / / / / / / / afterheating / preheating S version: Supporting bolts in the front and in the back DHSMT/I VD.K.6.02 Danfoss 11/2007

4 Special versions Special versions for different mediums, connections / couplings, max. operating pressures, materials and capacities are available on request. Please contact the local sales representative for details. ccessories Tailpieces for brazed heat exchanger type X Description Suitable for Connection Code No. Solder tailpieces Weldon tailpieces Threaded tailpieces n number of plates One set contains 2 tailpieces with unionnuts and gaskets X 04, X 06 X 24 (n<50) X 10, X 20 X 24 (n 50) X 30, X 36, X40 X 51 G ¾ / 15 mm G ¾ / 18 mm G 1 / 15 mm G 1 / 18 mm G 1 / 22 mm G 2 / 28 mm G 2 / 35 mm G 2 / 42 mm X 04, X 06 X 24 (n<50) G ¾ / DN X 10, X 20 X 24 (n 50) X 30, X 36, X 40 X 51 X 04, X 06 X 24 (n<50) X 10, X 20 X 24 (n 50) X 30, X 36, X 40 G 1 / DN 15 G 1 / DN 20 G 1 / DN 25 G 2 / DN 32 G 2 / DN 40 G 2 / DN 50 G ¾ / G ¾ G ¾ / G 1 G 1 / G ¾ H Mounting brackets for brazed heat exchanger type X X 04...X 40 X 51 X 60 X 70 Suitable for Code No. X 04, 06, X 24 <50 plates X plates X X 10, 20, 30, X X X actory assembled. Only to be ordered separately for service purposes. VD.K.6.02 Danfoss 11/2007 DHSMT/I

5 ccessories continued Insulation for 1pass brazed heat exchangers type X Type X 061 X 101 X 201 X 301 X 401 X 511 X 601 X 701 No of plates Insulation for 2pass brazed heat exchangers type X Type X 102 X 202 X 302 X 512 No of plates 20/20 26/ /30 36/ /40 46/ / / / /66 70/ afterheating / preheating Insulation properties Type PU (Polyurethane) see page 8 for X 06X 51 Coated steel sheet and polyester insulation, see page 8 for X 60X 70 Heatconductivity, λ [W/mK] Max temperature, C Permanent, C Short term peak, C Wall thickness, mm DHSMT/I VD.K.6.02 Danfoss 11/2007 5

6 Technical data 1pass brazed heat exchangers type X Type X 041 X 06L1 X06H1 X 101 X 201 X 241 X 301 X 361 X 401 X 51L1 X 601 X 70L1 X51H1 X 70M1 X 70H1 Max. working pressure (bar) 25 (16) 25(16)¹) / 16³) Max. operating temp. ( C) 180 Min. operating temp. 2) ( C) 10 low medium Circulation water / glycolic water up to 50% Volume/channel (litres) / ) Heat surface, m²/plate Connection type Cylindrical external thread acc. to DIN ISO 228/1 lange, DN Connection size G ¾ G 1 G ¾ (G 1)5) Plate material Stainless steel, mat. no razing material Copper G 1 G ) 65 4) 6) 3) / bar versions are available on enquiry (all types except X 041, 241, 36. X 701 secondary side: max. working pressure 16 bar 2) t flow temperatures below 2 C glycolic water must be used 3) Primary side / secondary side 4) langes PN 25 acc. to N 1092, facing type ( ⁵) or number of plates n 50 6) langes PN 16 acc. to N 1092, facing type ( 2pass brazed heat exchangers type X Heat exchanger heat surface (n2) * heat surface/plate n= number of plates Heat exchanger water volume Primary side Secondary side (n/2 * volume/channel n/2* volume/channel n= number of plates Type X 042 X 102 X 202 X 302 X 51L2, X 51H2 Max. working pressure (bar) 25 (16) Max. operating temp. ( C) 180 Min. operating temp. 2) ( C) 10 low medium Circulation water / glycolic water up to 50% Volume/channel (litres) Heat surface, m²/plate Connection type Cylindrical external thread acc. to DIN ISO 228/1 Connection size G ¾ G 1 G 2 Plate material Stainless steel, mat. no razing material Copper 16 bar versions are available on enquiry (all types except X 042). 2) t flow temperatures below 2 C glycolic water must be used Design and function T11 Primary side in T12 Primary side out T112 Primary side second inlet (2pass) T21 Secondary side in T22 Secondary side out T212 Secondary side second inlet (2 pass) The heat exchangers are made of shapepressed and brazed heat exchange plates, between which the flow channels are created. The heavy turbulence and counterflow principle enable efficient heat transfer. The task of the heat exchanger is to transfer heat from the primary to secondary flow through a heat transfer plate thus preventing the flows from mixing with each other. The choice of heat exchanger is determined by the desired heat output, required temperatures and the permitted pressure losses. The 2pass heat exchanger should be chosen for domestic hot water. The 2pass heat exchanger will often cool the district heating water to below 25 C. This capacity can be achieved by using a larger temperature difference, a smaller water flow and a heat exchanger with an optimum heat transfer area. This will affect the choice of motorized control valve, for instance. 6 VD.K.6.02 Danfoss 11/2007 DHSMT/I

7 Sizing Dimensioning and selection of heat exchangers should be carried out with the support of the Danfoss dimensioning program for heat exchangers. Mounting It is recommended to mount heat exchangers on their base in vertical position. This will assure the best venting and the least fouling. It is recommended that all pipes connected to the heat exchanger are equipped with shutoff valves for maintenance purposes. The pipes to be connected must be mounted so that the strain caused by the thermal expansion, for instance, does not harm the heat exchanger. The pipes must be equipped with brackets to prevent any torsional stress concentration at the heat exchanger s pipe connections. It is recommended that the heat exchanger is equipped with insulation. Disposal The brazed heat exchanger is made of valuable stainless steel and copper which can be recycled. Insulation sets can be disposed of in incineration plants thus recovering the energy or disposed of in landfills. lways follow local waste disposal regulations! Dimensions C C C Type Connection xternal dimensions [mm] Weight empty C/C1 D [kg] X G ¾ ¹) x n n x X G ¾ ¹) x n n x X 06 L... G ¾ ¹) n x 1, n x 0.08 X 06 H... G ¾ ¹) n x 1, n x 0.08 X 10 G x n n x 0.12 X 20 G x n n x 0.14 X 24...⁴) G ¾ ¹) x n n x 0.15 X 24...⁵) G x n n x 0.15 X 30 G x n 50 2+n x 0.18 X G x n n x 0.18 X 40 G x n 50 3+n x 0.25 X 51L X 51H... G x n 50 6+n x 0.38 X S⁷) X 51 S⁸) DN 50 2) x n 90 6+n x 0.38 X 60 X 60...S DN 65 2) x n n x 0.64 X 70L... X 70M... X 70H... DN 65 2) / 100 6) 3) / x n n x 1.50 n = number of plates (for 2pass heat exchangers the sum of afterheating and preheating plates) Cylindrical external thread acc. to DIN ISO 228/1 2) langes PN 25 acc. to N 1092, facing type ( ³) Primary side / secondary side D ⁴) or number of plates n < 50 ⁵) or number of plates n 50 ⁶) langes PN 16 acc. to N 1092, facing type ( ⁷) or number of plates n < 60 ⁸) or number of plates n 60 D X51... S C D D X70 X60 C1 DHSMT/I VD.K.6.02 Danfoss 11/2007 7

8 Dimensions continued lange connection d₂ d₂ n L1 Type DN L1 k n d 2 PN X51... S k X X70 65/ / /16 Primary side/ secondary side Insulation program (polyurethane) for brazed heat exchangers type X X 06,10, 20, 30, 40, 51 Type DN L1 k n d2 PN X50 G X X70 prim X70 sec Type (mm) (mm) No of plates [mm] X 60,70 Type (mm) (mm) No of plates [mm] 20/20 26/ /30 36/ /40 46/ / / / /66 70/ afterheating / preheating 8 VD.K.6.02 Danfoss 11/2007 DHSMT/I

Brazed heat exchanger, XB

Brazed heat exchanger, XB Brazed heat exchanger, Description / application The is a brazed plate heat exchanger designed for use with district heating systems (i.e. air conditioning, heating, domestic hot water). brazed plate heat

More information

Brazed heat exchanger XB

Brazed heat exchanger XB Description The XB is a range of copper brazed plate heat exchangers for use in District Heating (DH) and District Cooling (DC) applications, e.g. domestic hot water production, district heating substation

More information

ThermoDual Domestic hot water charging system

ThermoDual Domestic hot water charging system ThermoDual Domestic hot water charging system Description/Application ThermoDual is the compact and effective domestic hot water (DHW) charging system. Due to the consistent use of carefully selected components

More information

Quality Heat Exchangers

Quality Heat Exchangers Quality Heat Exchangers Brazed Plate Heat Exchangers Universal solutions for industrial and domestic applications With partnership into the future FUNKE is a leader in the development and production of

More information

Quality Heat Exchangers

Quality Heat Exchangers Quality Heat Exchangers Brazed Plate Heat Exchangers Universal solutions for industrial and domestic applications With partnership into the future FUNKE is a leader in the development and production of

More information

Air Cross 21 Installation and User Manual

Air Cross 21 Installation and User Manual Air Cross 21 Installation and User Manual 1 Introduction AirCross BPHE is a stainless steel cross flow plate heat exchange which is vacuume brazed with pure copper or nickel based material as the brazing

More information

TA-MATIC. Mixing valves Thermostatic mixing valve for domestic hot water

TA-MATIC. Mixing valves Thermostatic mixing valve for domestic hot water TA-MATIC Mixing valves Thermostatic mixing valve for domestic hot water IMI TA / Potable water / TA-MATIC TA-MATIC Thermostatic mixing valve for control of domestic hot water systems in apartment blocks

More information

Temperature controller AVT with safety temperature monitor STM / VGS for steam (PN 25)

Temperature controller AVT with safety temperature monitor STM / VGS for steam (PN 25) Data sheet Temperature controller AVT with safety temperature monitor STM / VGS for steam (PN 25) Description STW871 The controllers are: - Type-tested acc. to EN 14597 and protect against exceeding temperatures:

More information

Temperature controller for steam (PN 25) AVT / VGS - external thread

Temperature controller for steam (PN 25) AVT / VGS - external thread Data sheet Temperature controller for steam (PN 25) AVT / VGS - external thread Description The controller has a control valve VGS, thermostatic actuator and handle for temperature setting. Thermostatic

More information

FLOAT AND THERMOSTATIC STEAM TRAPS FLT17 (DN 1/2 to 1 ; DN15 to DN25)

FLOAT AND THERMOSTATIC STEAM TRAPS FLT17 (DN 1/2 to 1 ; DN15 to DN25) LOAT AND THERMOSTATIC STEAM TRAPS LT17 (DN 1/2 to 1 ; DN15 to DN25) DESCRIPTION LT17 float and thermostatic (integral air vent) steam traps series are designed for all types of low and high pressure steam

More information

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16) Data sheet Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16) Description XB06 IHPT The XB is a brazed plate heat exchanger designed for use with district heating systems

More information

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16) Data sheet Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16) Description XB06 IHPT The XB is a brazed plate heat exchanger designed for use with district heating systems

More information

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16) Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16) Description XB06 The XB is a brazed plate heat exchanger designed for use with district heating systems (i.e. air conditioning,

More information

Gasketed and brazed plate heat exchangers

Gasketed and brazed plate heat exchangers Gasketed and brazed plate heat exchangers Contents Gasketed plate heat exchangers Options Brazed plate heat exchangers Options 14 22 30 32 www.fiorinigroup.it 11 Gasketed and brazed plate heat exchangers

More information

SB Series Brazed Plate Heat Exchanger Installation Manual

SB Series Brazed Plate Heat Exchanger Installation Manual SB Series Brazed Plate Heat Exchanger Installation Manual HOT COLD Exploded view of Schmidt SB Brazed Plate Heat Exchanger. WARNING Before proceeding with installation and operation read entire manual

More information

ThermoClean Domestic water heating system with legionella growth prevention through thermal disinfection

ThermoClean Domestic water heating system with legionella growth prevention through thermal disinfection ThermoClean Domestic water heating system with legionella growth prevention through thermal disinfection Description/Application The ThermoClean system is compact and effective solution for legionella-free

More information

TA-MATIC

TA-MATIC TA-MATIC 3400 11-5-15 Thermostatic mixing valve for domestic hot water 2007.06 Technical description Application: Domestic hot water systems Function: The TA-MATIC 3400 is intended mainly as a central

More information

Brazed Plate Heat Exchanger Operations Manual

Brazed Plate Heat Exchanger Operations Manual razed Plate Heat Exchanger Operations Manual razed Exchanger Operations Manual razed Heat Exchangers from Polaris deliver exceptional strength and performance in a compact package. These versatile units

More information

Crown Boiler Company

Crown Boiler Company Crown Boiler Company 1 Phantom Boiler System Combi Kit Instruction Manual I Product Description This kit adds the ability to generate DHW, as well as heat, ( combi capability) to select Phantom models

More information

a Danfoss Platform for Flensburg Secondary Network

a Danfoss Platform for Flensburg Secondary Network DSP MINI a Danfoss Platform for Flensburg Secondary Network General description and application The DSP MINI is designed for use in district heating networks, suitable for heating and for providing DHW

More information

Eldon Product Overview

Eldon Product Overview Eldon Product Overview Product overview Floor Standing Enclosures page 4 Thermal Management page 32 Human Machine Interface page 26 Wall Mounted Enclosures page 12 Accessories page 38 Terminal Boxes page

More information

in/out connections outer Ø 25 bar (363 psi) 200 kg/h SS '000 (2.12 HP) 300 kg/h CU (661 lb/h) (3.18 HP) 300 kg/h SS (661 lb)

in/out connections outer Ø 25 bar (363 psi) 200 kg/h SS '000 (2.12 HP) 300 kg/h CU (661 lb/h) (3.18 HP) 300 kg/h SS (661 lb) CO 2 Vaporising Atmospheric ASCO CO 2 Vaporiser The atmospheric ASCO CO 2 Vaporiser has been developed to drastically reduce CO 2 vaporisation costs. Ambient air, which is available at no cost, is used

More information

Titanium Plate Heat Exchanger. Installation & Operating Manual

Titanium Plate Heat Exchanger. Installation & Operating Manual Titanium Plate Heat Exchanger Installation & Operating Manual Congratulations on your purchase of your Elecro Titanium PLATE HEAT EXCHANGER, manufactured in Hertfordshire, England to exacting standards

More information

HRU Heat Recovery Unit

HRU Heat Recovery Unit eneral description and application Danfoss Heat Recovery Unit provide the link between a Cooling unit and the heating installation. It is developed and designed for recovery of waste heat from refrigeration

More information

Brazed heat exchangers

Brazed heat exchangers HYGIENIC EQUIPMENT FOR FOOD & LIFE SCIENCES Brazed heat exchangers A product catalogue for refrigeration Refrigeration applications The brazed plate heat exchanger (BHE) is a well-established component

More information

Exhaust Gas Heat Exchangers

Exhaust Gas Heat Exchangers Exhaust Gas eat Exchangers eat Transfer Technology from owman eat Exchanger Technology by World Leader in eat Exchanger Technology Turning waste heat owman Exhaust Gas eat Exchangers Recovering valuable

More information

Quality Heat Exchangers

Quality Heat Exchangers Quality Heat Exchangers Brazed Plate Heat Exchangers Series TPL With partnership into the future FUNKE is a leader in the development and production of quality heat exchangers with a heat transfer area

More information

Domestic hot water (DHW) The substation can be supplied with connection pipes for DHW cylinder on the supply or return line.

Domestic hot water (DHW) The substation can be supplied with connection pipes for DHW cylinder on the supply or return line. MAKING MODERN LIVING POSSIBLE VX Solo II Substation for single-family, semi-detached and terraced houses as well as flats District heating substation for indirect heating. With connection pipes for W cylinder.

More information

Reflex Longtherm. Soldered plate-type heat exchanger. Operating instructions

Reflex Longtherm. Soldered plate-type heat exchanger. Operating instructions Reflex Longtherm Soldered plate-type heat exchanger 09-2016 EN Operating instructions English Refle x Longth erm Contents 09-2016 Contents 1 Safety... 3 1.1 Personnel requirements... 3 1.2 Instructions

More information

sustainable energy solutions

sustainable energy solutions EN sustainable energy solutions 2 Index Page 3 Index Page 4 Why accumulator tank? Page 5 Why Laddotank? Page 6-7 Buffer tank, PUFFER (500-2 000) Page 8-9 Buffer tank, PUFFER COMPACT (2 500-8 000) Page

More information

SL S.S.N.51D

SL S.S.N.51D GRUNDFOS DATA BOOKLET SL1.8..265.2.52S.S.N.51D Grundfos Pump 9814549 Thank you for your interest in our products Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/seslfam/9814549/sl1-8--265-2-52s-s-n-51d.html

More information

Level Electrode NRG NRG Original Installation Instructions English

Level Electrode NRG NRG Original Installation Instructions English Level Electrode NRG 10-52 NRG 16-52 EN English Original Installation Instructions 819123-02 Contents Important notes Page Usage for the intended purpose...4 Function...4 Safety note...4 Directives and

More information

VCYL. Liquid sight glasses 9.1 NEW. Refrigeration & Climate Components Solutions. Max WP 46 bar and multi-fluids (G1 or G2) n Applications

VCYL. Liquid sight glasses 9.1 NEW. Refrigeration & Climate Components Solutions. Max WP 46 bar and multi-fluids (G1 or G2) n Applications Refrigeration & limate omponents Solutions 9.1 n Applications Immediate and direct monitoring of flow, condition or moisture content of the refrigerant in its liquid or diphasic phase in refrigerating

More information

Valves, controls + systems. Innovation + Quality. Stations for solar energy and solid fuel boilers Product range

Valves, controls + systems. Innovation + Quality. Stations for solar energy and solid fuel boilers Product range Valves, controls + systems Innovation + Quality Stations for solar energy and solid fuel boilers Product range Stations for solar energy and solid fuel boilers Content Page Summary Stations for solar energy

More information

Operation and Maintenance Manual Sondex All-Welded Heat Exchangers (SAW)

Operation and Maintenance Manual Sondex All-Welded Heat Exchangers (SAW) Operation and Maintenance Manual Sondex All-Welded Heat Exchangers (SAW) The contents of this publication are based on the latest information available and the materials that are used at the time of printing.

More information

Model: 1200 Model: 1200-G Model: 1200-N Float-Controlled Condensate Trap, PN 40

Model: 1200 Model: 1200-G Model: 1200-N Float-Controlled Condensate Trap, PN 40 1 Safety instructions Model: 1200 Model: 1200-G Model: 1200-N Float-Controlled Condensate Trap, PN 40 1.1 Proper use Any improper use, intervention in the design and deviation from the design data automatically

More information

Choose the winning team. Heat transfer technology for industrial cooling and air conditioning

Choose the winning team. Heat transfer technology for industrial cooling and air conditioning Choose the winning team Heat transfer technology for industrial cooling and air conditioning Alfa Laval makes it easy Buying heat exchange components for industrial cooling and air conditioning projects

More information

AVTI Multifunctional self - acting controller

AVTI Multifunctional self - acting controller AVTI Multifunctional self - acting controller Description / Application AVTI is a self - acting combined controller developed for controlling small heat units with a room heating system and a hot service

More information

Sabroe MatchMaster Program COMP1

Sabroe MatchMaster Program COMP1 Page 1 of 5 File : 250313Q_1 Ref : CMAD Page : 1 Prog : COMP1/104509 Print : MIE ver. 6.0.2900.2180 SINGLE STAGE COMPRESSOR compressor type SAB 233 S male drive refrigerant R 717 number of compressors

More information

Operating Guide. Termix Solar A+/B+ 1.0 Table of Contents. 1.0 Table of Contents

Operating Guide. Termix Solar A+/B+ 1.0 Table of Contents. 1.0 Table of Contents 1.0 Table of Contents 1.0 Table of Contents... 1........................................................................ 2 2.0 Functional description... 3 3.0 Safety notes... 4 3.1 Safety Notes general............................................

More information

Installation and Operation Instructions Domestic hot water module FriwaMini with circulation - DN 15

Installation and Operation Instructions Domestic hot water module FriwaMini with circulation - DN 15 PAW GmbH & Co.KG Böcklerstr. 11, D-31789 Hameln, Germany Phone: +49-5151-9856-0, Fax: +49-5151-9856-98 E-mail: info@paw.eu, Web: www.paw.eu Installation and Operation Instructions Domestic hot water module

More information

VIESMANN. Installation instructions VITOCELL 300-V/W. for contractors. Vitocell 300-V/W Type EVIA-A

VIESMANN. Installation instructions VITOCELL 300-V/W. for contractors. Vitocell 300-V/W Type EVIA-A Installation instructions for contractors VIESMNN Vitocell 300-V/W Type EVI- DHW cylinder with internal indirect coil 160 to 500 l VITOCELL 300-V/W 3/2017 Dispose after installation. Safety instructions

More information

VIESMANN. Installation instructions VITOCELL 300-B. for contractors. Vitocell 300-B Type EVBA-A. Dual mode DHW cylinder, 300 and 500 l

VIESMANN. Installation instructions VITOCELL 300-B. for contractors. Vitocell 300-B Type EVBA-A. Dual mode DHW cylinder, 300 and 500 l Installation instructions for contractors VIESMANN Vitocell 300-B Type EVBA-A Dual mode DHW cylinder, 300 and 500 l VITOCELL 300-B 1/2017 Dispose after installation. Safety instructions Please follow these

More information

V2, V4 and V8 Thermostats Self-acting Temperature Controls I GB-1. Characteristics. Applications. Function. Design

V2, V4 and V8 Thermostats Self-acting Temperature Controls I GB-1. Characteristics. Applications. Function. Design GB-1 Characteristics Closing force 200 N, 400 N and 800 N For heating or cooling valves Sturdy and reliable Temperature range 0 to 160ºC (-30 to 280ºC on request) Applications The temperature controller,

More information

UltraHeat Plate and Frame Heat Exchangers. Engineered for Excellence

UltraHeat Plate and Frame Heat Exchangers. Engineered for Excellence UltraHeat Plate and Frame Heat Exchangers Engineered for Excellence Graham Corporation traces its history to the earliest development of heat transfer products in the United States during the 1920s, when

More information

LK Heat Exchanger Pack 10 -n

LK Heat Exchanger Pack 10 -n LK Heat Exchanger ack 10 -n 6 9 14 2 5 15 7 4 12 11 13 10 3 14 1 Design The LK Heat Exchanger ack -10 is primarily designed for glycol based under floor heating systems that must be isolated from other

More information

COMPANY PROFILE. F ounded in 1970, Kaori's goal is the pursuit of modernization of heat-treating

COMPANY PROFILE. F ounded in 1970, Kaori's goal is the pursuit of modernization of heat-treating COMPANY PROFILE F ounded in 197, Kaori's goal is the pursuit of modernization of heat-treating technology. Our staff has made every effort to improve on hardware and software, research & development, and

More information

Solar station DKP 6-8 / DKP Installation and Service Manual C

Solar station DKP 6-8 / DKP Installation and Service Manual C EN Solar station DKP 6-8 / DKP 9-20 Installation and Service Manual 300014274-001-C Contents 1 Introduction.............................................................................3 1.1 Used symbols...........................................................................................3

More information

Zeparo Cyclone. Automatic air vents and separators Dirt and magnetite separator with Cyclonic technology

Zeparo Cyclone. Automatic air vents and separators Dirt and magnetite separator with Cyclonic technology Zeparo Cyclone Automatic air vents and separators Dirt and magnetite separator with Cyclonic technology IMI PNEUMATEX / Air Vents, Dirt Separators and Degassing / Zeparo Cyclone Zeparo Cyclone Comprehensive

More information

UltraHeat Plate and Frame Heat Exchangers. Engineered for Excellence

UltraHeat Plate and Frame Heat Exchangers. Engineered for Excellence UltraHeat Plate and Frame Heat Exchangers Engineered for Excellence Graham engineers analyze your specific vacuum and heat transfer requirements to maximize the efficiency and performance of your process.

More information

PROTEGO Deflagration Flame Arresters. and Vent Caps. Volume 2. end-of line. Volume 2. for safety and environment

PROTEGO Deflagration Flame Arresters. and Vent Caps. Volume 2. end-of line. Volume 2. for safety and environment PROTEGO Deflagration Flame Arresters end-of line and Vent Caps Volume 2 Volume 2 Deflagration Flame Arresters, end-of-line, and Vent Caps Function and description The different combustion processes and

More information

SL EX.4.51D

SL EX.4.51D GRUNDFOS DATA BOOKLET SL1.1.1.75.EX.4.51D Grundfos pump 962669 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/sl1/962669/sl1-1-1-75-ex-4-51d-c.html

More information

Thermostatic Radiator Valves (Caleffi)

Thermostatic Radiator Valves (Caleffi) 02/09/16 B46 Thermostatic Radiator Valves (Caleffi) Thermostatic Control Heads Thermostatic control head fits radiator valves Set point locking mechanism Range stop adjustment Built-in sensor with liquid-filled

More information

Operation Manual. Time controlled condensate drain unit UFZ. 000_H_uf_UFZ_GB_R00_D011002

Operation Manual. Time controlled condensate drain unit UFZ. 000_H_uf_UFZ_GB_R00_D011002 Time controlled condensate drain unit UFZ 000_H_uf_UFZ_GB_R00_D011002 ultramatic UFZ Angular plug Time control unit Valve Control panel Pressure side connection Screw-type conduit fitting with strain relief

More information

Electric Water Heaters. The STRENGTHS of the product range in detail:

Electric Water Heaters. The STRENGTHS of the product range in detail: Electric Water Heaters The Styleboiler range of electric storage water heaters offers an extensive array of models for the production of domestic hot water (D.H.W.) with a capacity ranging from 10 to 1000

More information

NEPTUNE 2. Model: NEPTUNE 2-13 NEPTUNE 2-20 NEPTUNE 2-25 NEPTUNE 2-26 NEPTUNE 2-30 NEPTUNE 2-33 NEPTUNE 2-38 NEPTUNE Part List US-English

NEPTUNE 2. Model: NEPTUNE 2-13 NEPTUNE 2-20 NEPTUNE 2-25 NEPTUNE 2-26 NEPTUNE 2-30 NEPTUNE 2-33 NEPTUNE 2-38 NEPTUNE Part List US-English NEPTUNE 2 Model: NEPTUNE 2-13 NEPTUNE 2-20 NEPTUNE 2-25 NEPTUNE 2-26 NEPTUNE 2-30 NEPTUNE 2-33 NEPTUNE 2-38 NEPTUNE 2-41 Part List US-English Table of Contents NEPTUNE 2 Frame 3 Cabinet 5 Fueltank and

More information

35% Ultra-efficient brazed heat exchangers for your district energy applications. Up to. Brazed Micro Plate heat exchangers

35% Ultra-efficient brazed heat exchangers for your district energy applications. Up to.   Brazed Micro Plate heat exchangers Brazed Micro Plate heat exchangers Ultra-efficient brazed heat exchangers for your district energy applications Featuring the revolutionary Micro Plate technology innovation transferred Up to 35% lower

More information

Valves, controls + systems. Regucor WHS Energy storage centre. Innovation + Quality. Product range. v o. Awards: i y. n n

Valves, controls + systems. Regucor WHS Energy storage centre. Innovation + Quality. Product range. v o. Awards: i y. n n Valves, controls + systems Innovation + Quality Energy storage centre Product range ed v o r p m i y c n n for a y efficie g ener Awards: Energy storage centre Heating systems with regenerative energy

More information

THERMODYNAMIC STEAM TRAP

THERMODYNAMIC STEAM TRAP THERMODYNAMIC STEAM TRAP Model 041 Model 043 041 043 For the extraction of steam condensates. For use in: steam piping, irons, laundries, tanks and vessels with condensate discharge, multiple plate presses,

More information

EKS/HE. MultiScroll Air-cooled liquid chillers High efficiency. Solution B - Base I - Integrata

EKS/HE. MultiScroll Air-cooled liquid chillers High efficiency. Solution B - Base I - Integrata EKS/HE Refrigerant R410A GWP=2.088 Scroll Compressor Shell & Tube exchanger Axial fan Brazed plate heat exchanger MultiScroll Air-cooled liquid chillers High efficiency Solution B - Base I - Integrata

More information

BRAZED INSPECTED PLATE HEAT EXCHANGER SCAMBIATORI DI CALORE SALDOBRASATI ISPEZIONABILI CIESSE

BRAZED INSPECTED PLATE HEAT EXCHANGER SCAMBIATORI DI CALORE SALDOBRASATI ISPEZIONABILI CIESSE SERIE / I BRAZED INSPECTED PLATE HEAT EXCHANGER SCAMBIATORI DI CALORE SALDOBRASATI ISPEZIONABILI CIESSE Brazed PLATE HEAT EXCHANGER SERIES CIESSE DESCRIPTION The heat exchangers are essential components

More information

TA-COMFORT-S. Prefabricated units Heating interface unit for surface heating and hot water services

TA-COMFORT-S. Prefabricated units Heating interface unit for surface heating and hot water services TA-COMFORT-S Prefabricated units Heating interface unit for surface heating and hot water services IMI TA / Prefabricated units / TA-COMFORT-S TA-COMFORT-S All in one design with differential pressure

More information

EW447-EW452 Series Mechanical Heat Meters FOR HEATING AND COOLING APPLICATIONS

EW447-EW452 Series Mechanical Heat Meters FOR HEATING AND COOLING APPLICATIONS Design Hydronic meters of the EW447-452 Series consist of: Electronic energy integrator with fixed cable connection to the volume measuring component, supply and return temperature probe Mechanical volume

More information

Air-Drying Device. PROTEGO LA and LA/V. Function and Description LA/V. Figure 2 Figure 3

Air-Drying Device. PROTEGO LA and LA/V. Function and Description LA/V. Figure 2 Figure 3 Function and Description PROTEGO Air-drying device of types LA or LA/V is used when suction air must be dried for atmospheric venting of storage tanks where only little or no humidity is allowed to get

More information

NEOTeCHA Reactor Sampling Type PV

NEOTeCHA Reactor Sampling Type PV A safe and reliable sampling device to meet the demands of the chemical and pharmaceutical industry Features General applications To take a sample from reactors or vessels containing: poisoned media s

More information

BOILER HOUSE PRODUCTS GMS

BOILER HOUSE PRODUCTS GMS GMS BOILER HOUSE PRODUCTS Contents Page 2 Introduction 3 Condensate Pumpsets 6 Blowdown Vessels 8 Boiler Feed Tanks Page 10 Chemical Dosing Pots 11 Vent Heads 11 De-Aerator Heads Introduction to Boiler

More information

Heat exchanger plates

Heat exchanger plates The heat exchanger plate has the function to enable the transfer of heat between two fluids with different chemical-physical features, with no mixing between them. These, are preferred compared to shell

More information

SBB 300, 400 S & Sbb 300, 400, 600 Plus

SBB 300, 400 S & Sbb 300, 400, 600 Plus english Operating and Installation Instructions SINGLE AND DUAL HEAT EXCHANGER SOLAR STORAGE TANKS SBB 300, 400 S & Sbb 300, 400, 600 Plus WWW.STIEBEL-ELTRON-USA.COM SBB S & SBB PLUS SOLAR STORAGE TANKS

More information

Instructions for Installation, Operation, Care and Maintenance

Instructions for Installation, Operation, Care and Maintenance Bulletin 422 Model E Alarm Check Valve Bulletin 422 Instructions for Installation, Operation, Care and Maintenance DN100, DN150, DN200 SIZE Model E with E2 Euro Trim The Reliable Automatic Sprinkler Co.,

More information

TECHNICAL MANUAL Solar water heaters

TECHNICAL MANUAL Solar water heaters TECHNICAL MANUAL Solar water heaters Installation, maintenance & use instructions SOLAR WATER HEATERS CONTENTS GENERAL INFORMATION... DOMESTIC HOT WATER CONSUMPTION... SOLAR WATER HEATER OPERATION - WATER

More information

Safety vacuum drying oven for flammable solvents

Safety vacuum drying oven for flammable solvents VDL series 53 Vacuum drying ovens Safety vacuum drying oven for flammable solvents A BINDER safety vacuum drying oven of the VDL series ensures maximum safety when drying organic solvents standard with

More information

Transportation. Distribution

Transportation. Distribution Distribution Transportation Busbar Shielded Systems type: Cast Resin Low Voltage The shielded busbar system, ISOBUSBAR, type IS isolated in polyester or epoxy resin, have been specifically developed for

More information

5231 Series. Low Lead High Flow Thermostatic Mixing Valves. Installation, commissioning and service instructions ASSE 1017 NA10341

5231 Series.   Low Lead High Flow Thermostatic Mixing Valves. Installation, commissioning and service instructions ASSE 1017 NA10341 NA31 www.caleffi.com Low Lead High Flow Thermostatic Mixing Valves Copyright 1 Caleffi Installation, commissioning and service instructions Function 531 Series ASSE 17 model 531 series high flow thermostatic

More information

Metering & Thrust Gear Pumps. apompe.eu

Metering & Thrust Gear Pumps.  apompe.eu Metering & Thrust Gear Pumps Cast Iron (G25) aly It o, lan 0 09 7 i3 n do N S/ a zz re,t no 20 i,m l m po @ a ltr r dd,a.it a ltr Go s es pe ia :V u :u -m,e 4 46-0 39-0 39 + :+ x Fa 45 46 8 24, 52 + :+

More information

Hydronic Product & Application Catalog

Hydronic Product & Application Catalog Hydronic Product & Application Catalog Brazed Plate Heat Exchangers MJanuary 2005 for: Radiant Floor Heating Domestic Water Heating Snow Melt Swimming Pools Steam Close Approach High Pressure Systems Multi-Purpose

More information

CPM, CPMSP Cascade header kits Installation, Commissioning and Maintenance Instructions

CPM, CPMSP Cascade header kits Installation, Commissioning and Maintenance Instructions CPM, CPMSP Cascade header kits Installation, Commissioning and Maintenance Instructions CPM8 CPM77 CPM96 CPM116 CPMSP116 CPM144 CPM17 CPM_ANCIL/CASCADE_V1._December 201 INDEX 1. INTRODUCTION...3 2. MAIN

More information

TECHNICAL MANUAL HYPERION. Solar water heaters. Installation, maintenance & use instructions

TECHNICAL MANUAL HYPERION. Solar water heaters. Installation, maintenance & use instructions TECHNICAL MANUAL Solar water heaters HYPERION Installation, maintenance & use instructions HYPERION CONTENTS DOMESTIC HOT WATER CONSUMPTION... 4 SOLAR WATER HEATER OPERATION - WATER HEATING... 4 SOLAR

More information

LYRA 1000 VVS Installation and Operation Manual LYRA 1000 VVS THERMAL STORE LYRA 1000 VVS

LYRA 1000 VVS Installation and Operation Manual LYRA 1000 VVS THERMAL STORE LYRA 1000 VVS www.regulus.eu LYRA 1000 VVS Installation and Operation Manual LYRA 1000 VVS THERMAL STORE EN LYRA 1000 VVS CONTENTS 1 Description... 3 1.1 Models... 3 1.2 Tank protection... 3 1.3 Thermal insulation...

More information

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz EN Technical Catalogue Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: 321-1308 kw 50 Hz EKV/BS business Air cooled water chillers for outdoor installation. Flexibility in the

More information

Kallista Bath Flip Drain

Kallista Bath Flip Drain P21586 Page 1 of 7 THANK YOU FOR CHOOSING KALLISTA We appreciate your commitment to Kallista quality products. Please take a moment to review this manual before you install your Kallista product. If you

More information

CALEFFI. Thermostatic regulating unit for heating systems. 166 series 01238/17 GB. replaces dp 01238/15 GB. Function

CALEFFI. Thermostatic regulating unit for heating systems. 166 series 01238/17 GB. replaces dp 01238/15 GB. Function Thermostatic regulating unit for heating systems 66 series ACCREDITED ISO 9 FM 6 8/7 GB replaces dp 8/ GB Function The thermostatic regulating unit performs the function of keeping the flow temperature

More information

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers Self-adjusting electronic control Cooling capacity: 35 to 700 kw 410A Cooling Operation DYNACIAT - DYNACIAT POWER

More information

Brazed plate heat exchangers. By GEA PHE Systems Engineered by Kapp

Brazed plate heat exchangers. By GEA PHE Systems Engineered by Kapp Brazed plate heat exchangers By GEA PHE Systems Engineered by Kapp Brazed plate heat exchangers Concentrating on competence for your benefit Within the GEA Process Equipment Division of the international

More information

GESTRA Steam Systems DK 45. English. Installation Instructions Steam Trap DK 45

GESTRA Steam Systems DK 45. English. Installation Instructions Steam Trap DK 45 GESTRA Steam Systems DK 45 EN English Installation Instructions 818676-00 Steam Trap DK 45 1 Contents Important Notes Page Usage for the intended purpose...4 Safety note...4 Danger...4 Attention...4 PED

More information

MAXIMISER Semi-Storage Calorifiers

MAXIMISER Semi-Storage Calorifiers MAXIMISER Semi-Storage Calorifiers Introduction THE RYCROFT MAXIMISER HAS BEEN DEVELOPED TO MEET TODAY S NEED FOR A COMPACT CALORIFIER WHICH WILL RESPOND TO HIGH PEAK LOADS WITH MINIMAL DEMAND FOR BOILER

More information

HRS035-MS-022-RD 22 (559mm) 19mm x 30m 310mm Fixed Manual. HRS037-GI-019-RD 19 (483mm) 19mm x 36m 350mm Swing Manual

HRS035-MS-022-RD 22 (559mm) 19mm x 30m 310mm Fixed Manual. HRS037-GI-019-RD 19 (483mm) 19mm x 36m 350mm Swing Manual FIRE HOSE REEL CertIFIeD to Bs en 671-1: 1995 Certification No: Ps005704 BRITISH STANDARDS INSTITUTION APPROVAL FIRE HOSE REELS CERTIFIED TO BS EN 671 LICENCE NO. KM 51857 Certified Product AUSTRALIAN

More information

Sondex - A World of Heat Exchangers For All Applications

Sondex - A World of Heat Exchangers For All Applications Sondex - A World of Heat Exchangers For All Applications SONDEX HEAD OFFICE Sondex - A Leading Manufacturer of Plate Heat Exchangers Sondex A/S, a Danish company, was founded in 1984 by Mr. Aa. Søndergaard

More information

The theory behind heat transfer

The theory behind heat transfer Alfa Laval in brief Alfa Laval is a leading global provider of specialized products and engineered solutions. Our equipment, systems and services are dedicated to helping customers to optimize the performance

More information

Officine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0

Officine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0 Officine Meccaniche M.A.M. Apparecchiature Antideflagranti DOCUMENT IS-EJB-A-14 rev. 0 Instructions Flameproof enclosures EJB../W series for command, control, signaling and/or automation Emission date:

More information

LINDOFLAMM thermal engineering.

LINDOFLAMM thermal engineering. Catalogue LINDOFLAMM thermal engineering. Tailored solutions for every heating application. 02 LINDOFLAMM thermal engineering. Tailored solutions for every heating application. Contents. 03 All-round offering

More information

CBE BRAZED PLATE HEAT EXCHANGER

CBE BRAZED PLATE HEAT EXCHANGER CBE BRAZED PATE EAT EXCANGER Installation & Maintenance Manual STOKVIS ENERGY SYSTEMS KT8 TE: 020 8783 3050 FAX: 020 8783 3051 E-MAI: info@stokvisboilers.com WEBSITE: www.stokvisboilers.com 92099-9530

More information

Storage tank size Rated volume [l] Actual volume [l]

Storage tank size Rated volume [l] Actual volume [l] 10 Technical Data Volumes and heat loss Storage tank size 356 456 656 756 956 Rated volume [l] 350 450 650 750 950 Actual volume [l] 365 448 623 695 886 Hot water standby volume [l] Economy Standard Comfort

More information

Hakki Pilke Raven spare parts manual

Hakki Pilke Raven spare parts manual 1 ENGLISH Hakki Pilke Raven spare parts manual Valimotie 1, FI-85800 Haapajärvi, FINLAND Tel. +358 8 772 7300, Fax +358 8 772 732 info@maaselankone.fi, www.maaselankone.fi 2 Table of contents 1 Upper section

More information

Meibes Heat Interface Unit (HIU) A2RXE Instantaneous Hot Water & Space Heating

Meibes Heat Interface Unit (HIU) A2RXE Instantaneous Hot Water & Space Heating Meibes Heat Interface Unit (HIU) A2RXE Instantaneous Hot Water & Space Heating Product code A2RXE Founded in 1975 by Jan Aalberts. The enterprise has grown to an organisational structure in which group

More information

Partner Valve/High Quality Ball Valve LENO MSV-S

Partner Valve/High Quality Ball Valve LENO MSV-S Partner Valve/High Quality Ball Valve LENO MSV-S Description LENO MSV-S is a partner valve for all manual balancing valves in the LENO family. LENO MSV- S can also be applied as a high quality ball valve.

More information

Sealed Type Liquid Line and Suction Line Specifications

Sealed Type Liquid Line and Suction Line Specifications CATALOG 0 Page,, 4a, 404A, 407C, 40A, 0, 07 Also Compatible with Refrigerants, 4,, 40A & B, 40A & B, 408A, 409A The universal acceptance of the Catch-All Filter-Drier is due to its unique molded porous

More information

COLD WATER START A P P L I C AT I O N S

COLD WATER START A P P L I C AT I O N S COLD WATER START It is commonly known that prolonged internal condensation will dramatically shorten the life of standard efficiency boilers. While Raypak boilers can operate without harmful condensation

More information

Model AV Alarm Valve With and Without Model RC-1 Retard Chamber European Conformity Valve Trim General Description

Model AV Alarm Valve With and Without Model RC-1 Retard Chamber European Conformity Valve Trim General Description Worldwide Contacts www.tyco-fire.com Model AV--00 Alarm Valve With and Without Model RC- Retard Chamber European Conformity Valve Trim General Description The TYCO Model AV--00 Alarm Valves DN, DN0, DN0,

More information

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV 50 CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available November 2007 10 12 167 - GB -

More information

Fixtures Installation

Fixtures Installation Youth Explore Trades Skills Description Students will learn to install a toilet and lavatory basin. Lesson Outcomes The student will be able to: Install a toilet Install a lavatory basin Assumptions The

More information