DESIGN DATA THRs 2013

Size: px
Start display at page:

Download "DESIGN DATA THRs 2013"

Transcription

1 LESS ENERGY. FEWER EMISSIONS. MORE COMFORT. Gas condensing equipment & accessories DESIGN DATA THRs Draft projection 2013

2 Draft projection

3 CONTENTS Modern technology and the environment THRs condensing boilers Overview of THRs condensing boilers Internal description Boilers parameters Mounting dimensions Connecting dimensions Hydraulic characteristics The control system of THRs condensing boilers Control system technology Boiler control unit Basic accessories Boiler accessories for BSB bus connection Wireless accessories for THRs boiler LPB communication Web server Recommended connection diagrams Connection diagram T Connection diagram T Connection diagram T Connection diagram T Connection diagram T Connection diagram T Connection diagram T Connection diagram T Connection diagram T Connection diagram T Draft projection 2013

4

5 4 Draft projection 2013

6 LESS ENERGY. FEWER EMISSIONS. MORE COMFORT. Modern technology and the environment Thirty-year development and production of condensing equipment, focused from the very beginning only on the best solutions, has brought the products to an excellent technical level. Nowadays, the trend is not only the technologies themselves but top technologies essentially respecting our environment. The producer adheres to the Ecoefficience motto which actually means maximum efficiency, the lowest possible energy consumption and the amount of harmful emissions below the limit with the above-standard user comfort. The basis for success is the perfect design of Geminox condensing boiler equipped with the latest Siemens LMS control unit. The basic integrated control system has capabilities for easy expansion by alternative energy sources such as solar collectors, heat pumps etc. The unique technical solution ensures these 5 stages of fuel savings: 1) 2) 3) 4) 5) The first stage consists of condensation when such part of heat is utilized which escapes into a chimney in conventional boilers. This additionally gained heat is used to preheat return water from the central heating. The second stage is optimization of the combustion process in the entire power range of the boiler. Due to the constant air / gas ratio the patented circular burner with fuel (natural gas or propane) and air pre-mixing ensures maximum combustion efficiency with a minimum content of harmful emissions. The third stage is adaptable equithermal regulation integrated in Siemens LMS boiler control unit which prevents unnecessary exposure of walls of the building to cold and optimizes thermal comfort in the building and increases the efficiency of the entire heating system. Connection of solar collectors offers above-standard savings. The LMS control unit is prepared for easy expansion of the heating system by other alternative sources. The fourth stage is the intelligent speed control of a low-energy circulating pump of Class A. This feature significantly reduces the return water temperature during transition periods and thereby dramatically expands the zone of the use of condensation. Even the overall reduction in energy consumption is not insignificant. The fifth, the most important stage is represented by a wide linear modulation allowing uniform heating of the building without unnecessary cycling of the boiler. It is no secret that in 3/4 of the heating season % of the nominal power of the boiler is fully sufficient. All conventional boilers, in which the power cannot be reduced to the mentioned values while maintaining guaranteed efficiency, thus become very uneconomical for 3/4 of the heating season. One of the strongest benefits of THRs boilers is the ability to operate with maximum efficiency and without cycling even during the most common outdoor temperatures in the range of 5-15 C. This advantage is most evident in modern family houses. Today's new buildings usually have a heat loss around 10 kw. According to the above stated and practically-tested principles it is therefore necessary for the normal operation of such a building to reach the starting power of the boiler lower than 3 kw. If this parameter is not satisfied and the boiler is operated outside its operating range, the so-called cycling begins. Standard boilers with the starting power of 6-8 kw undergo such switching off and on up to 40,000 times per year. This number seems very untrustworthy but after a conversion to heating days in a year it means one start of the boiler every 10 minutes. However, we know from our experience that even minute intervals are no exception. The properly selected Geminox THRs condensing boiler will not make more than 4,000 starts per year. It must be clear even to an amateur what conclusion can be drawn from these data. A unique feature of THRs condensing boilers is the ability to change their output range. The increase or decrease of the boiler output range can be achieved by substituting the affordable burner and reprogramming the operating software. This innovative philosophy allows you to always optimally operate THRs condensing boilers. They do not force investors to make compromise purchases reflecting their future plans related to the increase in demands for heat production (extensions, heated swimming pools, indoor gardens, etc.). This achieves the standardized utilization degree within the range of % (PCI) in the whole modulated range. The result is 25 to 40% fuel savings compared to conventional boilers. By its focus, Procom Bohemia s.r.o., the exclusive importer of Geminox condensing boilers, supports only environmentally friendly equipment. It also acts environmentally friendly in its daily activities which is proven by the Environmental Management System Certificate ISO 14001:2005 for selling and servicing the ecofriendly thermal equipment. This system significantly helps to reduce the impact of company activities on the environment and also brings a significant reduction in operating costs. Procom Bohemia s.r.o. also strives to maintain a high level of services in the sale and service of eco-friendly thermal equipment and is therefore controlled by the Quality Management System according to ISO 9001:2009. Draft projection

7 6 Draft projection 2013

8 Condensing boilers THRs Condensing boilers THRs Designed even for the most demanding applications Already the fourth generation of condensing boilers with THRs (Trés Haut Rendement - very high efficiency) designation with the Siemens LMS control unit is designed for places where achieving the ideal thermal comfort with minimum operating costs is a clear priority. High quality design elements of boilers, such as the patented stainless steel burner, large stainless steel heat exchanger or stainless steel hot water tank, are complemented with the state-of-the-art Siemens LMS control unit. In addition to standard combustion and safety functions it controls one or more heating circuits including the hot water production. The basic equipment of the automatic system includes also the functions of solar heating, possibly a combination with alternative sources or cascade management. A wide range of power options is complemented with a double-circuit wiring or various combinations with water heating. The offer must cover the wishes of even the most demanding customers. Draft projection

9 Overview of THRs condensing boilers THRs C (DC) THRs M-75H (DC) THRs M-75V THRs 2-17M-75V THRs 1-10C THRs 2-17C THRs 5-25C THRs 2-17M-75H THRs 1-10DC THRs 2-17DC THRs 5-25DC THRs 2-17M-75HDC The boiler with an output range of 0.9 to 9.5 kw is used for heating of buildings with a very little heat loss, i.e. up to 10 kw. The basic version without hot water production can be completed by the external hot water tank (BS, MS, OKC) or a bivalent tank and thus ensure an adequate hot water reserve for its comfortable production even at a very low output range of the boiler. The boiler is typically used in low-energy and passive houses and is often used in conjunction with alternative energy sources (solar heating, heat pumps, etc..). It is the world's number one in the range of output modulation (10-100%). The boiler is also offered in the double-circuit DC version. The boiler with an output range of 2.3 to 16.9 kw is used for space heating with a heat loss of up to 17 kw. The basic version without hot water production can be completed by the external hot water tank (BS, MS, OKC) or a bivalent tank and thus ensure an adequate hot water reserve for its comfortable production even at a very low output range of the boiler. The boiler is specially designed for use in modern newly constructed family houses where it is capable to ensure optimal heating and thermal comfort due to its very low minimum output, without unnecessary and energy-intensive cycling. The boiler is also offered in the double-circuit DC version. The boiler with an output range of 4.8 to 23.9 kw is used for space heating with a heat loss of kw, especially conventional family houses and villas. The basic version without hot water production can be completed by the external hot water tank (BS, MS, OKC) or a bivalent tank and thus ensure a top-class comfort for its hot water production even in the case of a duplex living. The boiler is also offered in the double-circuit DC version. The boiler with an output range of 2.3 to 16.9 kw is used for space heating with a heat loss of up to 17 kw. Hot water heating is provided by an integrated stainless steel tank with a capacity of 75l which provides comfortable hot water production for one bathroom with a shower and standard bathtub. Due to its compact size and elegant design the boiler is suitable for placement in the interior and is usually used in flats and small newly constructed houses where it is an ideal solution thanks to its optimal output range and suitably chosen size of a hot water tank. The THRs 2-17M-75H boiler is also offered in a dual-circuit DC version. 8 Draft projection 2013

10 Condensing boilers THRs THRs SET (DC) THRs B-120 (DC) THRs (10-50)C THRs 1-10SET THRs 2-17SET THRs 5-25SET THRs 10-35C THRs 1-10SET-DC THRs 2-17SET-DC THRs 5-25SET-DC THRs 10-50C The boiler with an output range of 9.7 to 35.0 or 9.7 to 48.7 kw is used for larger space heating with a heat loss of kw or kw, especially in above-standard family houses, villas and commercial buildings. The basic design without a hot water production can be completed by the external stainless steel hot water tank of a suitable size and thus ensure an excellent comfort for hot water production THRs 1-10B-120 THRs 2-17B-120 THRs 5-25B-120 without any compromise. A sufficient boiler output enables you to implement demanding combinations of connecting a THRs 1-10B-120DC THRs 2-17B-120DC THRs 5-25B-120DC pool, air conditioning, heating and hot water heating. The set of the boiler with an external stainless steel hot water tank with a capacity of 120 or 150 litres, or an enamelled tank with a capacity of 120 or 160 litres, provides superior comfort and operating efficiency for use in modern newly constructed buildings with a low heat loss (THRs 1-10; THRs 2-17) as well as in traditional family houses and villas (THRs 5-25). The model with a 120 litre tank is a standard of modern living in single-family houses. Boilers are also offered in a dual-circuit DC version. Hot water heating is provided by an integrated stainless steel tank with a capacity of 120 litres which provides superior comfort and operating efficiency, both in newly constructed and conventional non-insulated family houses and villas. This direct alternative assembly THRs-SET is manly used for indoor location due to its new modern design and compact size. Compact assemblies with an integrated hot water tank are the most popular in a dual-circuit DC version. Boilers can be also connected to smart cascades with communication and you can achieve a linearly modulated output range 9.7 to 70 kw respectively 9.7 to 195 kw with a priority or simultaneous hot water production. These cascades can be completed by any number of heating circuits controlled by an integrated control unit or compatible Siemens RVS controllers of Albatros series. Draft projection

11 Internal description THRs C 9 ፚ The boiler is equipped with a preparation for connecting an external hot water tank with priority heating 11 ፚ The boiler is equipped with an expansion tank with a capacity of 8 l A circulating pump of hot water can be installed into a boiler housing THRs B-120DC 1. plastic flue 2. stainless steel circular burner with pre-mixing 3. gas fitting 4. optical flame control peephole 5. side cover of the expansion tank space 6. large stainless steel heat exchanger 7. fan with speed control 8. multifunctional Siemens LMS control unit 9. controlled pump of the first heating circuit 10. servo drive + mixing valve of the 2nd heating circuit 11. hot water distributing valve 12. pump of the 2nd heating. circuit The boiler is equipped with an expansion tank with a capacity of 18 l 13. inlet valve of central heating 14. safety sensor of floor heating overheating 15. heating water pressure sensor 16. condensate discharge trap 17. central heating safety valve 18. stainless steel hot water. tank 120 l 19. hot water temperature sensor 20. hot water drain valve THRs M-75V ፚ V (vertical) model has a tank located under the boiler ፚ The boiler is equipped with an expansion tank with a capacity of 10 l 10 Draft projection 2013

12 Condensing boilers THRs THRs DC THRs M-75H THRs M-75HDC ፚ The boiler is equipped with a complete set for control of a mixing heating circuit ፚ The boiler is equipped with a set for connecting an external hot water tank with priority heating ፚ The boiler is not equipped with an expansion tank ፚ H (horizontal) model has a tank located on the right side next to the boiler ፚ The boiler is equipped with an expansion tank with a capacity of 8 l ፚ The boiler is equipped with a complete set for control of a mixing heating circuit ፚ The boiler is not equipped with an expansion tank ፚ The boiler contains a threeway valve for hot water heating THRs 10-50C THRs 10-35C ፚ The boiler is equipped with a preparation for connecting an external hot water tank with priority heating ፚ The boiler is not equipped with an expansion tank ፚ The boiler is prepared for the installation of a set for connecting an external hot water tank THRs SET-125 (160) THRs SET-120 THRs SET-150 Draft projection

13 Boilers parameters 0.9 to 16.9 kw Boiler type 1-10C* 1-10B-120* 2-17C* 2-17M-75V 2-17M-75H* 2-17B-120* design single tank 120 l single tank 75 l tank 75 l tank 120 l homologation CE0085AT0244 output modulation range % multifunctional control unit SIEMENS LMS 14 LMS 14 second (mixing) heating circuit SIEMENS clip-in AGU AGU output utilization degree heat input rated power 80/60 C output of heat 50/30 C kw kw kw /42 CEE % /60 C % /30 C % burner circular pre-mixing pre-mixing natural gas consumption G20 m 3 /h propane consumption G31 kg/h. - - combustion air consumption max. m 3 /h flue chimney/turbo B23 + C13 / C33 B23 + C13 / C33 maximum comb. products temp. 75/60 C C comb. products flow rate kg/h usable fan overpressure Pa CO2 GN % 8 9,5 8 9,5 GP % - - NOx (class No.5) 3% O2 mg/m average mg/m CO 3% O2 mg/m average mg/m loss during the standby mode heat Tk 70 ºC W Tk 40 ºC W exchanger flow rate nominal l / h min. l / h heat exchanger pressure drop Kv 3,6 3,6 operating overpressure maximum water temperature volume of water CH bar 1 3 (4**) 1 3 (4**) HW bar CH C HW C CH l HW l acc. to cont. 123 acc. to cont expansion tank capacity l maximum power input operation W *** *** stand by W voltage/frequency V/Hz 230/50 230/50 electrical protection B C B C IP IP pump GRUNDFOS - UPM UPM noise level at minimum output distance 1 m db (A) width mm depth mm height mm flue mm mm 80/125 80/125 gas inlet 1 1 CH inlet/outlet 1 1 HW inlet/outlet - 1-3/4 3/4 1 output of condensate discharge mm outlet of safety valve 3/4 3/4 weight w/o water kg * also in a double-circuit DC version ** on request *** in a dual-circuit DC version it is necessary to add the power of a three-speed pump for MTO I. = 40 W, II. = 60 W, III. = 80 W 12 Draft projection 2013

14 Condensing boilers THRs 4.8 to 48.7 kw Processed in the system TechCON Boiler type 5-25C* 5-25M-75V 5-25M-75H* 5-25B-120* 10-35C 10-50C design single tank 75 l tank 75 l tank 120 l single single homologation CE0085AQ0543 CE0085AR0323 CE0085AR0323 output modulation range % multifunctional control unit SIEMENS LMS 14 LMS 14 LMS 14 second (mixing) heating circuit SIEMENS clip-in AGU AGU AGU heat input kw output standardized utilization degree rated power 80/60 C kw output of heat 50/30 C kw /42 CEE % /60 C % /30 C % burner circular pre-mixing pre-mixing natural gas consumption G20 m 3 /h propane consumption G31 kg/h combustion air consumption max. m 3 /h flue chimney/turbo B +C /C B +C /C maximum comb. products temperature 75/60 C C comb. products flow rate kg/h usable fan overpressure Pa CO NO (class No.5) CO 2 x loss during the standby mode heat exchanger flow rate operating overpressure maximum water temperature volume of water GN % GP % % O 2 mg/m average mg/m % O 2 mg/m average mg/m T 70 C W k T 40 C W k nominal l/h min. l/h CH bar 1 3 (4**) 1 3 (4**) 1 3 (4**) HW bar CH C HW C CH l HW l acc. to cont acc. to cont. expansion tank capacity l external maximum power input operation W *** voltage/frequency electrical protection standby W V/Hz 230/50 230/50 B 23 IP C 33 IP pump GRUNDFOS - UPM UPS noise level at minimum output distance 1 m db (A) width mm depth mm height mm flue B 23 mm C 33 mm 80/125 80/125 gas inlet 1 1 CH inlet/outlet 1 1 HW inlet/outlet - 3/4 3/4 1 - output of condensate discharge mm output of safety valve 3/4 3/4 weight w/o water kg * also in a double-circuit DC version ** on request *** in a dual-circuit DC version it is necessary to add the power of a three-speed pump for MTO I. = 40 W, II. = 60 W, III. = 80 W Draft projection

15 C G D K C D C D Mounting dimensions H THRs I THRs H THRs B-120 E F E F E F top view bottom view top view Ø 7 Ø 7 B A A J A A B B A A A A B THRs M-75H THRs C THRs 50C Type A B C D E min. F min. G H I J THRs C, DC THRs 10-50C , THRs M75 V THRs M75 H (DC) Ø 7 THRs B-120 (DC) B A A A A B The method of flue Flue with an insert in the chimney, air supply from the space with the boiler K Ø mm Ø mm Ø 7 Flue with an insert in the chimney, air supply by the chimney Ø 125/ mm B A A A A B THRs M-75V Flue with an insert in the chimney, air supply by the pipe from the outside Ø mm Ø mm Warning: ፚ When designing the boiler location it is essential to observe the distances of E min., F min. ፚ The boiler must be freely and safely accessible. ፚ The minimum distance between the boiler and hot water tank (e.g. in a THRs SET-120 set) is 230 mm. Failure to observe these requirements would prevent installation and servicing. If smaller distances are necessary, consult the technical department of the importer. 14 Draft projection 2013

16 Condensing boilers THRs Connecting dimensions THRs 1-10C, 2-17C, 5-25C THRs 10-35C, 10-50C flue DN gas inlet 1 3. CH outlet 1 4. CH return pipe 1 5. outlet to a HW tank 1 6. HW tank return pipe 1 7. condensate discharge DN20 8. safety valve overflow 3/4 9. electrical outlets 1. flue DN gas inlet 1 3. CH outlet 1 4. CH return pipe 1 5. outlet to a HW tank 1 6. HW tank return pipe 1 7. condensate discharge DN20 8. safety valve overflow 3/4 9. electrical outlets Draft projection

17 THRs 2-17M-75V, 5-25M-75V THRs 2-17M-75H, 5-25M-75H flue DN gas inlet 1 3. CH outlet 1 4. CH return pipe 1 5. cold water inlet 3/4 6. HW outlet 3/4 7. condensate discharge DN safety valve overflow 3/4 9. electrical outlets 1. flue DN gas inlet 1 3. CH outlet 1 4. CH return pipe 1 5. cold water inlet 3/4 6. HW outlet 3/4 7. condensate discharge DN safety valve overflow 3/4 9. electrical outlets 16 Draft projection 2013

18 Condensing boilers THRs THRs 1-10DC2-17DC, 5-25DC Frame with an expansion tank for THRs DC flue DN gas inlet 1 3. direct heating circuit outlet 1 (radiators) 4. direct heating circuit return pipe 1 (radiators) 5. outlet of HW tank heating 1 6. return pipe of HW tank heating 1 7. condensate discharge DN20 8. safety valve overflow 3/4 9. return pipe of the mixing heating circuit 1 (floor heating) 10. outlet of the mixing heating circuit 1 (floor heating) 11. expansion tank connection 1" 12. electrical outlets Draft projection

19 ± ± THRs 2-17M-75H DC, 5-25M-75H DC THRs B-120, B-120 DC flue DN gas inlet 1 3. direct heating circuit outlet 1 (radiators) 4. direct heating circuit return pipe 1 (radiators) 5. cold water inlet 3/4 6. HW outlet 3/4 7. condensate discharge DN20 8. safety valve overflow 3/4 9. return pipe of the mixing heating circuit 1 (floor heating) 10. outlet of the mixing heating circuit 1 (floor heating) 11. expansion tank connection 1" 12. electrical outlets 1. flue DN gas inlet 1 3. direct heating circuit outlet 1 4. direct heating circuit return pipe 1 5. cold water inlet 3/4 6. HW outlet 3/4 7. condensate discharge DN safety valve overflow 3/4 Only double-circuit DC version 9. outlet of the mixing heating circuit return pipe of the mixing heating circuit 1 Note: Circulation inside the tank uses free openings in the cover. 18 Draft projection 2013

20 ±10 818±10 805±10 843±10 876±10 910±10 934±10 976± ± ± ±10 Condensing boilers THRs Draft projection

21 Hydraulic characteristics Characteristics of Grundfos UPM pump + pressure drop of the heat exchanger of THRs 1-10, 2-17, 5-25 boiler The data are processed in the system TechCON (m) K = 3.6 v 3 2 Pressure drop of the heating 1 set e.g. 17 kpa Pressure drop of the heat exchanger THRs l/h. (10 kw - T 15 C) l/h. (17 kw - T 15 C) l/h. (25 kw - T 15 C) (l/h) Unless there is no curve available after the sum of the pressure drops of the heat exchanger and the designed heating set, it is necessary to supplement the heating system with the extra circulating pump. Characteristics of Grundfos UPS pump for the second mixed heating circuit THRs DC The data are processed in the system TechCON (m) K = 4 v kg/h kg/h l/hour 7 kw at T 5 C 12 kw at T 8 C Grundfos UPS pump and a three-way valve with ESBE servo-drive (Kv = 4) are integrated during production in the THRs DC boiler and are parts of the hydraulic connection of the second (mixed) heating circuit designed for floor heating (see diagram T2). The design process of the mixed heating circuit (MTO): With the design temperature difference (according to ČSN EN 1264 we design T = 5 C for floor heating) and the given heat loss of the floor heating circuit the required flow is determined for MTO. The pressure drop of the mixing valve (K v = 4) is subtracted from the flow. The subtraction of the heat exchanger pressure drop is performed by increasing the temperature of boiler water by 5 C compared to MTO. Therefore, we subtract the heat exchanger pressure drop at a lower flow rate but at the same power! This elevation difference is preset by the boiler control. Example: If we design MTO with a gradient of T = 5 C, then the pressure drop of the boiler heat exchanger (K v =3.6) is subtracted at T = 10 C. It is necessary for the MTO design that the required overpressure remains to cover the pressure drop of the system. If the MTO pump will not cover the sum of pressure drops, it is necessary to design the pump with higher performance. It is not possible to replace the MTO pump in a double-circuit THRs DC boiler. It follows that in this case you cannot use the double-circuit THRs DC boiler. So we choose the hydraulic connection according to 2B and 2C diagrams. Examples MTO limit performances: 7 kw at T 5 C, approx kpa remains for MTO. 12 kw at T 8 C, approx kpa remains for MTO. 20 Draft projection 2013

22 flow quantity (m 3 /h) Condensing boilers THRs Characteristics of Grundfos UPS pump + optimized pressure drop of the heat exchanger of THRs 10-35, boiler The data are processed in the system TechCON (m) K = 3.6 v l/h. Geminox optimized the stainless steel heat exchanger by reducing the pressure drop which improved the utilization in the most common applications. Unless there is no curve available after the sum of the pressure drops of the heat exchanger and the designed heating set, it is necessary to supplement the heating system with the extra circulating pump. A set for HW heating in the external tank/thrs AB-B AB-A ,1 1 pressure drop (m v. sl.) 10 1 Kv = 8.6 The valve is integrated in the boiler so it is necessary to take into account its hydraulic loss when designing the heating system with priority HW heating. Draft projection

23 The control system of THRs condensing boilers In recent years we have seen a sharp increase in requirements for the systems intended to control condensing boilers. These requirements have already exceeded the basic requirements for safe operation of gas appliances and combustion process control. Nowadays, the equithermal control of the heating circuit and HW production are a common standard of the burner automatic system of the boiler. But even such a concept of the control board is not able to systematically work in technologies with several heating circuits, in boiler cascades or in multivalent systems. Nor is it able to provide constant monitoring of the entire application using remote monitoring via the internet connection. Siemens, the supplier of the entire control system of condensing boilers, combined its long-time experience with the latest results of the work of several development teams and launched a topclass concept. The resulting product is the burner automatic system. However, in its basic design it must not unnecessarily increase the price of the boiler. Therefore, it only has inputs and outputs for above-standard control of one equithermal circuit and HW production. However, it also offers the possibility of separate control of the circulating pump and addition of sensors and control of HW solar heating. This feature gives Geminox boilers a competitive advantage. The users of this unique technology are also allowed to select from several types of room units, economical or highly comfortable, and from their wireless models. In the case of larger technologies (e.g. several heating circuits, cascades) the LMS burner automatic system has a absolutely unique feature. It integrates almost all functions of the Siemens RVS control system of Albatros2 series. After connecting the extension modules (they complement inputs and outputs) to the LMS automatics we obtain the same opportunities of control of resources (solid fuel boiler, solar collectors) and appliances (up to three mixed heating circuits, swimming pool, external appliances, etc.). The extension modules are offered as accessories, in a version for installation in the boiler (Clip-in) and in a version for installation into the box (for example at a mixed heating circuit). At first glance the unnecessary duplication of features always offers the ideal combination of the system set with regard to the price, building layout, the length of cable routes and many other criteria. As an example, the following two typical cascade applications can be mentioned. The first is a simple "legislative" cascade of 2 x 49kW with HW production and one mixed circuit (Fig. 22.1). The additional RVS regulation can be left out here and we can take advantage of the properties of the boiler automatic system. Savings in this application reach tens of hundreds of dollars. The second case can be a block of flats where after disconnecting from the central heating system the distributor with heating circuits remains in the basement and the boilers cascade will be installed in the attic (Fig. 22.2). Here, from the perspective of price, labour-intensiveness and cabling it will be more convenient to use the RVS regulator to control the boiler room and connect the boilers only by a two-wire communication cable. The quality of the control system is a prerequisite for correct and optimal functioning of any heating system. With the increasing complexity the work of service technicians is still more and more important. Siemens took this into account when creating the system. Due to the unification of the control concept, menu structure, PC tools and sharing of functional blocks it is now possible to ensure 100% transfer of gained knowledge and equipment of technicians between equithermal regulators, boiler automatic systems and heat pumps, for example. In order to diagnose problems the system has detailed information on the conditions of individual parts of the technology, showing actual and desired temperatures. For more demanding users that require remote monitoring and convenient adjustment of parameters via PC, mobile phones or smart TV and in order to completely improve the service operability it is beneficial to complement the boiler automatic system with Webserver OZW672 for Internet communication. Fig Fig Draft projection 2013

24 Condensing boilers THRs Control system technology Wireless receiver QAA78 Wireless multifunctional room unit QAA58 Wireless room unit QAC34 Outdoor sensor + AVS13 Wireless transmitter for outdoor sensor QAC34 outdoor sensor Service tool QAA75 QAA55 QAA55 QAA75 Multifunctional Room room unit unit Optional accessories for the 2nd heating circuit for THRs DC version OCI700 Extension Clip-In modules Communication module RVS regulators Web server Possibility of up to three modules Built-in module RVS Equithermal regulator OZW672 Draft projection

25 CLIP-IN No. 2 (solar) CLIP-IN No.1 (2nd heating circuit) Boiler control unit boiler automatic system is a digital control unit designed for gas condensing boilers with a modulated burner. In terms of priorities, its main task is to ensure the safe operation of a gas appliance in all circumstances and optimum control of the combustion process. Its biggest advantage, compared to the competing products, is a possible extension by a group of accessories enabling the use of all its features. To connect peripherals the unit has an internal BSB bus (Boiler System Bus). It is a firm connection using a two-wire, respectively three-wire cable. Two neighbouring devices communicate over distances up to 200 m with a limit of the total length of wiring to 400 m. If there is no pre-prepared wiring, you can connect the room devices and outdoor sensor by using radio communication at 868 MHz. The distance for radio communication connection cannot be unambiguously determined as it depends on the structure of the building. Generally, the distance of 30 m is stated, or even three walls/two floors. In structures with difficult radio signal propagation or to extend the reach the product range also includes a signal amplifier. The second communication bus which serves to connect the additional RVS regulation or other automatic systems is LPB (Local Process Bus). It is used in larger systems of resources and appliances. This option is gained automatically after connecting the communication Clip-in module. Boiler wiring diagram LED - OFF LMS without power supply LED - ON LMS running LED - flashes LMS failure 24 Draft projection 2013

26 Condensing boilers THRs Basic accessories Outdoor sensor QAC34 In most cases, the system of equithermal control system is chosen for heating the building, with or without the influence of the interior temperature. The equithermal control system of Geminox condensing boilers ensures perfect thermal comfort throughout the building, significantly reducing energy consumption and extending the equipment life. The condition of use of the system is to install the outdoor sensor. Information about the outside temperature provides also some security features such as protection of the heating system from local freezing. The sensor is connected to the control unit by a two-wire cable in a maximum distance of 120 m. Due to its timeless design it does not disturb the appearance of the facade. Integrated control panel AVS The basic user interface of THRs boilers is the control panel AVS which allows access to all parameters. These are clearly arranged to three service levels according to the operator authorization. The system diagnostic has information on actual and desired temperatures and operating conditions of each component of the technology. The control panel is integrated into the design of the Geminox boiler and is connected to the control unit by a special flat cable. 1. Electrical connection 230V-50 Hz 2. Programmable output - QX2* 3. Switching valve of HW heating - QX ; 17; 25 kw programmable output - QX1* 5. 35; 50 kw pump TO 230 V - QX1* 6. 10; 17; 25 kw pump TO 230 V, power supply of the Clip-in 7. extension module - AUX ; 50 kw power supply of the Clip-in extension module - AUX2 9. Fan 230 V - AUX1 10. Emergency thermostat (STB) 230 V 11. Ignition transformer 12. Gas fitting 230 V 13. Ionization electrode 14. Programmable input - H6* 15. Freely programmable sensor - BX1* 16. Combustion products sensor - BX2 17. Hot water sensor ECS2 - BX3 18. Hot water sensor ECS1 - B3/B Outdoor sensor - B9 20. Programmable input - H1* 21. Programmable input - H4* 22. Programmable input - H5* 23. Clip-in LPB 24. Pressure sensor - H3 25. Temperature sensor of the CH return pipe - B7 26. Boiler temperature sensor - B2 27. Multifunctional room unit (QAA75, QAA55...) 28. Control panel AVS37 - X Radio module connection (antenna AVS71) 30. Restore factory parameters - X12 clamp 31. Connection of the clip-in module (optional) 32. Fan PWM control 33. Circulating pump PWM control 34. Fuses (2 x 6.3 A (H250)) 35. Clip-in pump of the 2nd heating circuit (Q6) 36. Clip-in pump of the solar heating (Q5) 37. Motor of the mixing valve (clip-in of the 2nd heating circuit) 38. Relay output, available in QX22 for solar clip-in* 39. Relay output, available in QX21 for solar clip-in* 40. Sensor output of the 2nd heating circuit (clip-in of the 2nd heating circuit) 41. Relay input, available in BX22 for clip-in of the 2nd heating circuit 42. Solar sensor (solar clip-in) 43. Water temperature sensor at the bottom of the solar hot water tank (solar clip-in) 44. Addressing clip-in N. 1 = 2nd heating circuit (optional) 45. Addressing clip-in no. 2 = solar (optional) 46. ON / OFF control 47. LED (power supply or LMS failure) * Optional, see clip-in (= extension module) QX... / BX... Draft projection

27 Boiler accessories for BSB bus connection Room unit QAA Comfortable room unit with a backlit display (three-wire connection as a condition). It complements the control strategies with the equithermal regulation with the influence of room temperature or purely space control. It is equipped with controls for quick change of the desired comfortable temperature, operating mode of the heating circuit, switching hot water on/off and with a presence button. There is also an information button to display temperatures and operating conditions of equipment. The device allows full access to all control parameters including time programmes adjustment as in the integrated control panel of THRs boilers. It can be assigned to a specific heating circuit or it can control all circuits together. Room unit QAA A basic room unit with a two-wire connection. It complements the control strategies with the equithermal regulation with the influence of room temperature or purely space control. It is equipped with controls for correction of the desired comfortable temperature, switching the operating mode of the heating circuit, switching hot water on/off and with a presence button. The unit is assigned to a particular heating circuit and is complemented by the possibility of operation deadlock for the installation in public areas. Extension clip-in module The basic function of the expansion module is to complement the terminal box of the boiler automatic system with other two sensor inputs, one H input (potential-free contact/0-10v) and three relay outputs to configure additional functions. A typical application is the control of the mixed heating circuit as in THRs DC boilers. However, the possibilities of use of inputs/outputs are much broader. The structural design is adapted to the installation directly in the boiler. The electronics cabinet of Geminox boilers has prepared positions for a maximum number of three modules. A multiple flat cable with keyed connectors is used for connection. Extension module AVS In terms of features and use, this module is identical with the clip-in module. The main difference is in the type of construction. It is designed for the installation outside the boiler into the junction box near the technology (e.g. mixing heating circuit, wood boilers). The connection cable can be extended up to 200 m. PWM clip-in module AGU2.551 A built-in module is designed for connecting the boiler with the master control. It contains two PWM signal converters to 0-10 V signal and two potential-free relays. The master control can get information about the fan speed (current boiler output) and speed of the boiler pump using the standard 0-10 V signal. The outputs of the boiler operation and failure can be connected to the relay. The module is powered from the BSB bus and does not limit the number of connectable extension modules (AVS75.390). 26 Draft projection 2013

28 Condensing boilers THRs Wireless accessories for THRs boiler Radio transmitter/receiver AVS The basic prerequisite for the use of wireless peripheral devices with the boiler automatic system is the connection of the radio module. RF module AVS is the basic model with an integrated flat cable (1 m) for connection to a specific connector fitted on the automatic system board. This fixed connection may limit the choice of location. The module must not be fitted to the interior of the boiler. Therefore, we prefer to use the module AVS described below. Radio transmitter/receiver AVS Also this RF module extends the features of the control board of the possibility to connect radio peripherals. Unlike the AVS module it is connected by a three-wire cable to the BSB bus and its installation is therefore possible to a distance of 200 m from the boiler. This allows us to choose an optimal location for installation with the best reception. Room units QAA and QAA Both radio room units are identical copies of wire models QAA and QAA They allow the use of all their functions without specific demands for placement (while respecting the basic installation rules). The only difference is the absence of the backlight. The units communicate bidirectionally with the possibility of testing the quality of signal transmission. They are powered by AA batteries with a life expectancy of up to three years. Outdoor temperature transmitter AVS The device is installed in the interior and has an outdoor sensor QAC34 placed in the same position on the outside of the perimeter wall connected by a two-wire cable. It is important for the easy replacement of batteries and the battery capacity is not adversely affected by low ambient temperature. The outdoor temperature transmitter is powered by AAA batteries with a life expectancy of up to three years. When installing the outdoor sensor QAC34 it is necessary to respect the basic installation rules. RF signal repeater AVS In case of installation in buildings with very poor radio signal propagation or to extend the reach the system can be complemented by the AVS repeater. The transmitting power is identical with other elements and allows the range to be doubled. It is powered by a drawer adapter that is included. Draft projection

29 LPB communication LPB clip-in module Communication module is used to connect multiple boilers in cascades and/or to make connection with RVS and RVD regulators. The module is equipped with a special connector and does not limit the number of connected extension clip-in modules (AVS75.390). The maximum number of devices on the LPB bus is 16. Temperature sensors Contact sensor QAD36 It is the most common sensor for sensing heating water temperature. Its advantage is easy installation on a pipe with a diameter of mm, without using the heat sink. The sensor is equipped with a sensing element NTC 10k Ohm. It is connected to the control unit by a two-wire cable with a maximum distance of 120 m. The temperature range is -30 to 125 C. Heat sink sensor QAZ36 The sensor is designed to sense the temperature in the HW tank or in the storage tank. If the pipe is equipped with a heat sink the sensor can be also used for measuring the temperature of heating water. Its advantage is low price. It comes with an integrated cable, 6 m in length. It is connected to the control unit by a two-wire cable with a maximum distance of 120 m. The temperature range is 0 to 95 C. Heat sink solar sensor QAZ It is a special version of the heat sink sensor NTC 10k Ohm with a higher temperature range of -30 to 200 C, with a 2m integrated cable with silicone insulation. It is primarily intended to measure the temperature of solar collectors but its another very good use is also measuring the temperature of embedded fireplace inserts with a heat exchanger. It is connected to the control unit by a two-wire cable with a maximum distance of 120 m. 28 Draft projection 2013

30 Condensing boilers THRs Web server Remote control of the heating system via the Internet Ideal tool for easy control and operation of the boiler control system from anywhere in the world. In case of a fault an alarm is sent via or SMS to predefined recipients. By installing the Web server the user obtains the possibility to be connected to the system of comprehensive maintenance services including remote monitoring by the central control centre. Providing the equipment importer with the access to the web server extends the boiler warranty by 12 months. Webserver OZW672 Web server OZW672 offers its users the ability to remotely control and receive alarm messages via the Internet using a PC or smartphone. Commissioning and operation are very simple. Since the web server is directly integrated into the OZW672, all you need is the Internet connection in the house. Therefore, the use of the web server requires no additional operating costs. If OZW672 is connected to the boiler control unit, all setting changes are automatically taken over and are immediately available on-line. For easy and fast commissioning of the device you have a starting page available with the most important data points. Draft projection

31 Ethernet TCP/IP Webserver Connect GW RB750 Connecting the web server to the Internet environment can be performed in two ways: ፚ Connection using a static public IP address - established by the Internet provider. ፚ Connection using RB750 - webserver Connect GW. A simple system to of web server connection to the Internet network without establishing a static public IP address. The device automatically ensures a secure port redirecting through the Brilon server farm. The system requires only a connection to the electricity network and the Internet. This service is completely free and is suitable for large networks in commercial buildings. ACS Tool remote administration Web server is a very useful tool for remote monitoring of equipment by your maintenance technician. It allows immediate intervention to the boiler control system and long-term monitoring of operating parameters. Due to the service tool you can fully remotely manage also the parameters of the burner automatic system. Wiring diagram with a static IP address Internet DSLrouter Ethernet TCP/IP DSLrouter Web browser Web browser IP address: Subnemt ask: Defaulgtateway: PreferredDNSserver: IP address: Subnemt ask: OZW IP address: Subnemt ask: Defaulgtateway: PreferredDNSserver: Draft projection 2013

32 Condensing boilers THRs A generated individual hydraulic diagram provides a quick overview of the most monitored parameters. Any data points can be easily added and edited. Clear user interface allows easy control and monitoring of the system on-line. Full remote administration by the maintenance technician using the service program saves time and money. Draft projection

33 Recommended connection diagrams Considering a huge number of combinations of sources and equipment connections that can be controlled by the LMS boiler automatic system in combination with clip-in modules and the RVS regulator system the following list of recommended connections was developed. The aim was not to describe all possibilities but the most common technologies. Those were chosen with regard to the typical customer requirements, experience from implemented installations and long life. The key to work with the diagram catalogue BSB Operation using room units B9 QAC34 B2 230 V/50 Hz 10 A B7 ROOM UNIT QAA ROOM UNIT QAA EXP Q1 Y3 RADIATORS OR FLOOR HEATING Q4 (QX2) TV Additional function: HW circulating pump (Q4) B3 B6 (BX1) B31 (BX2) SV Q5 (QX1) Additional function: collector pump (Q5) collector sensor (B6) HW solar sensor (B31) K18 (QX23) B13 (BX21) K18 (QX23) Additional function: pool pump (K18) pool sensor (B13) 32 Draft projection 2013

34 Condensing boilers THRs It is always the connection of the gas boiler or boiler cascade and the heating circuit. If the basic connection allows it, the diagram is always completed with an alternative for connecting HW, additional heating circuits, sources (solar, fireplace), swimming pool or external appliances. Our goal was to create the basis for a simple design of the system in a recommended hydraulic connection. It contains a basic description and specification of necessary components to order. There are also necessary basic information for wiring and placement of sensors. Operation using wireless room units Terminology of sensors and relays WIRELESS ROOM UNITS: AVS WIRELESS RECEIVER QAA ROOM RECEIVER QAA ROOM UNIT ROOM UNIT QAA WIRELESS RECEIVER AVS ROOM UNIT QAA QAZ HEAT SINK HW B3 (PART OF THE HW HEATING KIT) QAZ HEAT SINK HW B3 (PART OF THE HW HEATING KIT) QAZ HEAT SINK SOLAR B6 QAZ HEAT SINK BOTTOM HW B31 Multifunctional inputs and outputs BX1 BX3 QX1 QX2 BX1 BX3 QX1 QX2 Q4 BX1 BX3 B6 B31 LEGEND B1 SETUP TO1 B12 SETUP TO2 B13 POOL B15 PRE-REGULATION B2 BOILER B22 WOOD BOILER B3 TOP HW B31 BOTTOM HW B39 HW CIRCULATION B4 ACCUMULATION TOP B41 ACCUMULATION BOTTOM B42 ACCUMULATION INTERMEDIATE B6 COLLECTOR B7 RETURN PIPE B10 CASCADE SETUP B70 CASCADE RETURN PIPE B73 COMMON RETURN PIPE B8 COMBUSTION PRODUCTS TEMP. B9 OUTDOOR TEMP. Q1 BOILER PUMP Q2 PUMP TO1 Q3 HW PUMP/VALVE Q4 HW CIRCULATION PUMP Q5 COLLECTOR PUMP Q6 PUMP TO2 Q10 WOOD BOILER PUMP Q11 ACU CHARGING PUMP Q14 FEED PUMP Q15 PUMP H1 Q18 PUMP H2 Q19 PUMP H3 Q20 DIRECT HC PUMP Y1/2 MIXER TO1 Y5/6 MIXER TO2 Y15 RETURN PIPE VALVE Y19/20 PRE-REGULATION VALVE K6 EL. HEATING ELEMENT HW K8 SOLAR PUMP FOR ACU K18 SOLAR PUMP FOR POOL QX1 Q5 QX2 Q4 - EXTENSION MODULE QAZ HEAT SINK HW B3 (PART OF THE HW HEATING KIT) QAZ HEAT SINK SOLAR B6 QAZ HEAT SINK BOTTOM HW B31 QAD36 - POOL CONTACT B13 BX1 BX3 B6 B31 QX1 QX2 Q5 Q4 BX21 BX22 H2 B13 QX21 QX22 QX23 K18 Draft projection

35 Connection diagram T1 Basic connection of the THRs condensing boiler intended for one direct heating circuit (radiators or floor heating) with a possibility to be extended by HW heating in an indirectly heated tank by a bypass valve (absolute priority). Furthermore, the control can be supplemented by HW solar heating or HW and a swimming pool. BSB B9 QAC34 B2 230 V/50 Hz 10 A B7 ROOM UNIT QAA ROOM UNIT QAA EXP Q1 Y3 RADIATORS OR FLOOR HEATING Q4 (QX2) TV B3 B6 (BX1) B31 (BX2) SV Q5 (QX1) K18 (QX23) B13 (BX21) K18 (QX23) 34 Draft projection 2013

36 Condensing boilers THRs WIRELESS ROOM UNITS: AVS WIRELESS RECEIVER QAA ROOM RECEIVER QAA ROOM UNIT ROOM UNIT QAA WIRELESS RECEIVER AVS ROOM UNIT QAA QAZ HEAT SINK HW B3 (PART OF THE HW HEATING KIT) QAZ HEAT SINK HW B3 (PART OF THE HW HEATING KIT) QAZ HEAT SINK SOLAR B6 QAZ HEAT SINK BOTTOM HW B31 BX1 BX3 QX1 QX2 BX1 BX3 QX1 QX2 Q4 BX1 B6 BX3 B31 QX1 Q5 QX2 Q4 LEGEND B1 SETUP TO1 B12 SETUP TO2 B13 POOL B15 PRE-REGULATION B2 BOILER B22 WOOD BOILER B3 TOP HW B31 BOTTOM HW B39 HW CIRCULATION B4 ACCUMULATION TOP B41 ACCUMULATION BOTTOM B42 ACCUMULATION INTERMEDIATE B6 COLLECTOR B7 RETURN PIPE B10 CASCADE SETUP B70 CASCADE RETURN PIPE B73 COMMON RETURN PIPE B8 COMBUSTION PRODUCTS TEMP. B9 OUTDOOR TEMP. Q1 BOILER PUMP Q2 PUMP TO1 Q3 HW PUMP/VALVE Q4 HW CIRCULATION PUMP Q5 COLLECTOR PUMP Q6 PUMP TO2 Q10 WOOD BOILER PUMP Q11 ACU CHARGING PUMP Q14 FEED PUMP Q15 PUMP H1 Q18 PUMP H2 Q19 PUMP H3 Q20 DIRECT HC PUMP Y1/2 MIXER TO1 Y5/6 MIXER TO2 Y15 RETURN PIPE VALVE Y19/20 PRE-REGULATION VALVE K6 EL. HEATING ELEMENT HW K8 SOLAR PUMP FOR ACU K18 SOLAR PUMP FOR POOL - EXTENSION MODULE QAZ HEAT SINK HW B3 (PART OF THE HW HEATING KIT) QAZ HEAT SINK SOLAR B6 QAZ HEAT SINK BOTTOM HW B31 QAD36 - POOL CONTACT B13 BX1 B6 BX3 B31 QX1 Q5 QX2 Q4 BX21 B13 BX22 H2 QX21 QX22 QX23 K18 Draft projection

37 Connection diagram T2 Basic connection of the double-circuit THRs DC condensing boiler intended for one direct and one mixed heating circuit with a possibility to be extended by HW heating in an indirectly heated tank by a bypass valve (absolute priority). Furthermore, the control can be supplemented by HW solar heating or HW and a swimming pool. B9 QAC34 BSB B2 ROOM UNIT QAA V/50 Hz 10 A B7 ROOM UNIT QAA ROOM UNIT QAA ROOM UNIT QAA FLOOR HEATING B12 Y5/6 STB Q6 COMPLET E! Q1 EXP Y3 RADIATORS Q4 (QX2) TV B3 B6 (BX1) B31 (BX2) SV Q5 (QX1) K18 (QX23) B13 (BX22) K18 (QX23) 36 Draft projection 2013

38 Condensing boilers THRs WIRELESS ROOM UNITS: AVS WIRELESS RECEIVER QAA ROOM RECEIVER QAA ROOM UNIT ROOM UNIT QAA WIRELESS RECEIVER AVS ROOM UNIT QAA QAZ HEAT SINK HW B3 (PART OF THE HW HEATING KIT) QAZ HEAT SINK HW B3 (PART OF THE HW HEATING KIT) QAZ HEAT SINK SOLAR B6 QAZ HEAT SINK BOTTOM HW B31 LEGEND BX1 BX3 BX21 BX22 H2 B1 SETUP TO1 B12 SETUP TO2 B12 B13 B13 POOL B15 PRE-REGULATION QX1 QX2 QX21 QX22 QX23 B2 BOILER Y5 Y6 Q6 B22 WOOD BOILER B3 TOP HW B31 BOTTOM HW B39 HW CIRCULATION B4 ACCUMULATION TOP B41 ACCUMULATION BOTTOM B42 ACCUMULATION INTERMEDIATE B6 COLLECTOR B7 RETURN PIPE B10 CASCADE SETUP B70 CASCADE RETURN PIPE B73 COMMON RETURN PIPE B8 COMBUSTION PRODUCTS TEMP. B9 OUTDOOR TEMP. Q1 BOILER PUMP BX1 BX3 BX21 BX22 H2 Q2 PUMP TO1 B12 B13 Q3 HW PUMP/VALVE Q4 HW CIRCULATION PUMP Q5 COLLECTOR PUMP QX1 QX2 QX21 QX22 QX23 Q6 PUMP TO2 Q4 Y5 Y6 Q6 Q10 WOOD BOILER PUMP Q11 ACU CHARGING PUMP Q14 FEED PUMP Q15 PUMP H1 Q18 PUMP H2 Q19 PUMP H3 Q20 DIRECT HC PUMP BX1 BX3 BX21 BX22 H2 Y1/2 MIXER TO1 Y5/6 MIXER TO2 B6 B31 B12 B13 Y15 RETURN PIPE VALVE Y19/20 PRE-REGULATION VALVE QX1 QX2 QX21 QX22 QX23 K6 EL. HEATING ELEMENT Q5 Q4 Y5 Y6 Q6 HW K8 SOLAR PUMP FOR ACU K18 SOLAR PUMP FOR POOL - EXTENSION MODULE QAZ HEAT SINK HW B3 (PART OF THE HW HEATING KIT) QAZ HEAT SINK SOLAR B6 QAZ HEAT SINK BOTTOM HW B31 QAD36 - POOL CONTACT B13 BX1 BX3 BX21 BX22 H2 BX21 BX22 H2 B6 B31 B12 B13 QX1 QX2 QX21 QX22 QX23 QX21 QX22 QX23 Q5 Q4 Y5 Y6 Q6 K18 Draft projection

39 Connection diagram T3 Basic connection of the THRs condensing boiler designed for one direct or one direct and one mixed heating circuit. Or for connecting external appliances with a variable flow, heat demand signal 0-10V (optionally ON / OFF), with a possibility of extension by HW heating in an indirectly heated tank by a bypass valve (absolute priority) or a pump (all variants of production priority). Furthermore, the control can be supplemented by HW solar heating or HW and a swimming pool. BSB B9 QAC34 B2 230 V/50 Hz 10 A B7 ROOM UNIT QAA ROOM UNIT QAA EXP Q1 Y3 RADIATORS OR FLOOR HEATING B10 (BX1) ZV Q4 (QX2) TV Q3 B12 Q6 RADIATORS OR FLOOR HEATING LY B3 OPTIONAL Y5/6 ZV B6 (BX21) B31 (BX22) SV Q5 (QX23) K18 (QX22) B13 (BX22) K18 (QX22) 38 Draft projection 2013

40 Condensing boilers THRs WIRELESS ROOM UNITS: AVS WIRELESS RECEIVER QAA ROOM RECEIVER QAA ROOM UNIT ROOM UNIT QAA WIRELESS RECEIVER AVS ROOM UNIT QAA QAD36 - SETUP CONTACT B10 - EXTENSION MODULE TO2 QAD36 - SETUP CONTACT B10 QAZ HEAT SINK HW B3 (PART OF THE HW HEATING KIT) QAD36 - SETUP CONTACT TO2 B12 - EXTENSION MODULE TO2 - EXTENSION MODULE QAD36 - SETUP CONTACT B10 QAZ HEAT SINK HW B3 (PART OF THE HW HEATING KIT) QAD36 - SETUP CONTACT TO2 B12 QAZ HEAT SINK (PART OF THE HW HEATING KIT) QAZ HEAT SINK SOLAR B6 QAZ HEAT SINK BOTTOM HW B31 BX1 BX3 B10 QX1 QX2 Q2 BX1 BX3 BX21 BX22 H2 B10 B12 QX1 QX2 QX21 QX22 QX23 Q2 Q4 Y5 Y6 Q6 BX1 BX3 BX21 BX22 H2 BX21 BX22 H2 B10 B12 B6 B31 QX1 QX2 QX21 QX22 QX23 QX21 QX22 QX23 Q2 Q4 Y5 Y6 Q6 Q5 LEGEND B1 SETUP TO1 B12 SETUP TO2 B13 POOL B15 PRE-REGULATION B2 BOILER B22 WOOD BOILER B3 TOP HW B31 BOTTOM HW B39 HW CIRCULATION B4 ACCUMULATION TOP B41 ACCUMULATION BOTTOM B42 ACCUMULATION INTERMEDIATE B6 COLLECTOR B7 RETURN PIPE B10 CASCADE SETUP B70 CASCADE RETURN PIPE B73 COMMON RETURN PIPE B8 COMBUSTION PRODUCTS TEMP. B9 OUTDOOR TEMP. Q1 BOILER PUMP Q2 PUMP TO1 Q3 HW PUMP/VALVE Q4 HW CIRCULATION PUMP Q5 COLLECTOR PUMP Q6 PUMP TO2 Q10 WOOD BOILER PUMP Q11 ACU CHARGING PUMP Q14 FEED PUMP Q15 PUMP H1 Q18 PUMP H2 Q19 PUMP H3 Q20 DIRECT HC PUMP Y1/2 MIXER TO1 Y5/6 MIXER TO2 Y15 RETURN PIPE VALVE Y19/20 PRE-REGULATION VALVE K6 EL. HEATING ELEMENT HW K8 SOLAR PUMP FOR ACU K18 SOLAR PUMP FOR POOL SEE PREVIOUS TABLE + QAD36 - POOL CONTACT B13 BX1 BX3 BX21 BX22 H2 BX21 BX22 H2 B6 B31 B12 B13 B6 B31 QX1 QX2 QX21 QX22 QX23 QX21 QX22 QX23 Q5 Q4 Y5 Y6 Q6 K18 Q5 Draft projection

41 Connection diagram T4 Basic connection of the THRs condensing boiler designed for one to three mixed / direct heating circuits. Or for connecting external appliances with a variable flow, the heat demand signal 0-10V (optionally ON / OFF), with a possible extension of HW heating in an indirectly heated tank by a charging pump (all variants of production priority). Furthermore, the control can be supplemented by HW solar heating. B9 QAC34 BSB B2 230 V/50 Hz 10 A B7 ROOM UNIT QAA ROOM UNIT QAA EXP Q1 B10 (BX1) B1 RADIATORS OR FLOOR HEATING Q4 (QX2) TV Q2 B3 Q3 Y1/2 ZV Q6 (BX22) B12 Q6 RADIATORS OR FLOOR HEATING Q5 (QX1) B31 (BX2) Y5/6 ZV SV B14 Q20 RADIATORS OR FLOOR HEATING Y11/12 ZV 40 Draft projection 2013

42 Condensing boilers THRs WIRELESS ROOM UNITS: AVS WIRELESS RECEIVER QAA ROOM RECEIVER QAA ROOM UNIT ROOM UNIT QAA WIRELESS RECEIVER AVS EXTENSION MODULE QAD36 - CONTACT TO1 QAZ HEAT SINK HW B3 (PART OF THE HW HEATING KIT) ROOM UNIT QAA BX1 BX3 B10 QX1 QX2 BX1 BX3 BX21 BX22 H2 B10 B1 QX1 QX2 QX21 QX22 QX23 Q4 Y1 Y2 Q2 LEGEND B1 SETUP TO1 B12 SETUP TO2 B13 POOL B15 PRE- REGULATION B2 BOILER B22 WOOD BOILER B3 TOP HW B31 BOTTOM HW B39 HW CIRCULATION B4 ACCUMULATION TOP B41 ACCUMULATION BOTTOM B42 Q14 FEED ACCUMULATION PUMP Q15 PUMP H1 Q18 PUMP H2 Q19 PUMP H3 Q20 DIRECT HC PUMP Y1/2 MIXER TO1 Y5/6 MIXER TO2 Y15 RETURN PIPE VALVE Y19/20 PRE-REGULATION VALVE K6 EL. HEATING ELEMENT HW K8 SOLAR PUMP FOR ACU K18 SOLAR PUMP FOR POOL - EXTENSION MODULE TO1 - EXTENSION MODULE TO2 QAD36 - CONTACT TO1 QAD36 - CONTACT TO2 QAZ HEAT SINK HW B3 (PART OF THE HW HEATING KIT) QAZ HEAT SINK SOLAR B6 QAZ BOTTOM HW B31 BX1 BX3 BX21 BX22 H2 BX21 BX22 H2 B10 B31 B1 B6 B12 QX1 QX2 QX21 QX22 QX23 QX21 QX22 QX23 Q5 Q4 Y1 Y2 Q2 Y5 Y6 Q6 - EXTENSION MODULE TO1 - EXTENSION MODULE TO2 - EXTENSION MODULE TO3 QAD36 - CONTACT TO1 QAD36 - CONTACT TO2 QAD36 - CONTACT TO3 QAZ HEAT SINK HW B3 (PART OF THE HW HEATING KIT) QAZ HEAT SINK SOLAR B6 QAZ BOTTOM HW B31 BX1 BX3 B10 B31 QX1 QX2 Q5 Q4 BX21 BX22 B1 B6 H2 QX21 QX22 QX23 Y1 Y2 Q2 BX21 BX22 H2 B12 QX21 QX22 QX23 Y5 Y6 Q6 BX21 BX22 H2 B14 QX21 QX22 QX23 Y11 Y12 Q20 Draft projection

43 Connection diagram T5 Basic connection of the THRs condensing boiler designed for individual rooms temperature control using the Siemens Synco Living system, with a variant of dividing appliances into two temperature gradients (radiators / floor heating) and HW production. This connection is intended for other control systems in individual rooms or generally for external appliances. The boiler control is performed by an analogue signal of the desired temperature 0-10V, or ON / OFF with equithermal pre-regulation (via LMS). CENTRAL UNIT QAX910 KNX B2 230 V/50 Hz 10 A B7 230 V/50 Hz 6 A EXP Q1 KNX SSA 955 Y3 RADIATORS Q B10 (BX1) ZV FLOOR HEATING STA V/50 Hz X Q Y ZV Q TV B3 SV 42 Draft projection 2013

44 Condensing boilers THRs METEOROLOGICAL QAC 910 KNX QAA910 ROOM 0 10 V DC KNX UTP CABLE INTERNET RRV V/50 Hz 6 A RRV V/50 Hz 6 A QAD36 - SETUP CONTACT B10 QAD36 - SETUP CONTACT B10 QAD22 - HEATING CIRCUIT CONTACT KNX KNX RRV V/50 Hz 6 A RRV V/50 Hz 6 A LEGEND B1 SETUP TO1 B12 SETUP TO2 B13 POOL B15 PRE-REGULATION B22 WOOD BOILER OZW B3 TOP HW BX1 BX3 H1 B31 BOTTOM HW WEB INTERFACE 230 V/50 Hz B10 10V DC B39 HW CIRCULATION B4 TOP ACCUMULATION QX1 QX2 B41 BOTTOM ACCUMULATION B6 COLLECTOR K10 B7 RETURN PIPE B10 CASCADE SETUP B70 CASCADE RETURN PIPE B73 COMMON RETURN PIPE B8 COMBUSTION PRODUCTS TEMP. B9 OUTDOOR TEMP. Q1 BOILER PUMP Q2 PUMP TO1 Q3 HW PUMP/VALVE Q4 HW CIRCULATION PUMP Q5 COLLECTOR PUMP Q6 PUMP TO2 Q10 WOOD BOILER PUMP Q11 ACU CHARGING PUMP Q14 FEED PUMP Q15 PUMP H1 BX1 BX3 H1 Q18 PUMP H2 B10 10V DC Q19 PUMP H3 Q20 DIRECT HC PUMP QX1 QX2 K10 Y1/2 MIXER TO1 Y5/6 MIXER TO2 Y15 RETURN PIPE VALVE Y19/20 PRE-REGULATION VALVE K6 EL. HEATING ELEMENT K8 SOLAR PUMP FOR ACU K10 ALARM OUTPUT K18 SOLAR PUMP FOR POOL QAD36 - SETUP CONTACT B10 QAD22 - HEATING CIRCUIT CONTACT QAP22 - HEAT SINK HW BX1 BX3 H1 B10 10V DC QX1 QX2 K10 Draft projection

45 Connection diagram T6 Basic connection of the THRs boiler cascade (max. 16 boilers) designed for one to three mixed / direct heating circuits. Or for connecting external appliances with a heat demand signal 0-10 V (optionally ON / OFF), with a possible extension of HW heating in an indirectly heated tank by a charging pump (all variants of production priority). Furthermore, the control can be supplemented by HW solar heating. In this connection the features of LMS automatic system are maximally used. It saves the cost of control system but the "all of boilers" is B9 QAC34 LPB BOILER NO. 1 BOILER NO. 2 BOILER NO V/50 Hz 10 A B2 B2 B2 B7 B7 B7 Q1 Q1 Q1 B10 (BX1) Q4 (QX2) TV Q3 B3 B6 (BX22) B31 (BX2) Q5 (QX1) SV 44 Draft projection 2013

46 Condensing boilers THRs demanding for wiring implementation. It is suitable for smaller outputs where it is not necessary to fit the power switches to outputs in a separate switchboard box unit. It is always necessary to consider whether the T7 connection is better for the given installation. BASIC REGULATION: 3 - COMMUNICATION INTERFACE LPB BX1 BX3 B10 QX1 QX2 ROOM UNIT QAA ROOM UNIT QAA B1 Q2 RADIATORS OR FLOOR HEATING 2 - COMMUNICATION INTERFACE LPB - EXTENSION MODULE TO1 QAD36 - CONTACT TO1 QAZ HEAT SINK HW B3 (PART OF THE HW HEATING KIT) BX1 BX3 B10 QX1 QX2 Q4 BX21 BX22 H2 B1 QX21 QX22 QX23 Y1 Y2 Q2 Y1/2 ZV B12 Q6 Y5/6 RADIAT ORS OR FLOOR HEATING ZV 2 - COMMUNICATION INTERFACE LPB - EXTENSION MODULE TO1 - EXTENSION MODULE TO2 QAD36 - CONTACT TO1 QAD36 - CONTACT TO2 QAZ HEAT SINK HW B3 (PART OF THE HW HEATING KIT) QAZ HEAT SINK SOLAR B6 QAZ BOTTOM HW B31 BX21 BX22 H2 BX21 BX22 H2 BX1 BX3 B1 B6 B12 B10 B31 QX21 QX22 QX23 QX21 QX22 QX23 Y1 Y2 Q2 Y5 Y6 Q6 RADIATORS OR 2 - COMMUNICATION INTERFACE LPB - EXTENSION MODULE TO1 - EXTENSION MODULE TO2 B14 FLOOR - EXTENSION MODULE TO3 HEATING Q20 QAD36 - CONTACT TO1 QAD36 - CONTACT TO2 QAD36 - CONTACT TO3 QAZ HEAT SINK HW B3 Y11/12 (PART OF THE HW HEATING KIT) QAZ HEAT SINK SOLAR B6 ZV QAZ BOTTOM HW B31 BX1 BX3 BX21 BX22 H2 BX21 BX22 H2 BX21 BX22 H2 B10 B31 B1 B6 B12 B14 QX1 QX2 QX21 QX22 QX23 QX21 QX22 QX23 QX21 QX22 QX23 Q5 Q4 Y1 Y2 Q2 Y5 Y6 Q6 Y11 Y12 Q20 LEGEND B1 SETUP TO1 B12 SETUP TO2 B13 POOL B15 PRE-REGULATION B2 BOILER B22 WOOD BOILER B3 TOP HW B31 BOTTOM HW B39 HW CIRCULATION B4 ACCUMULATION TOP B41 ACCUMULATION BOTTOM B42 ACCUMULATION INTERMEDIATE B6 COLLECTOR B7 RETURN PIPE B10 CASCADE SETUP B70 CASCADE RETURN PIPE B73 COMMON RETURN PIPE B8 COMBUSTION PRODUCTS TEMP. B9 OUTDOOR TEMPERATURE Q1 BOILER PUMP Q2 PUMP TO1 Q3 HW PUMP/VALVE Q4 HW CIRCULATION PUMP Q5 COLLECTOR PUMP Q6 PUMP TO2 Q10 WOOD BOILER PUMP Q11 ACU CHARGING PUMP Q14 FEED PUMP Q15 PUMP H1 Q18 PUMP H2 Q19 PUMP H3 Q20 DIRECT HC PUMP Y1/2 MIXER TO1 Y5/6 MIXER TO2 Y15 RETURN PIPE VALVE Y19/20 PRE-REGULATION VALVE K6 EL. HEATING ELEMENT K8 SOLAR PUMP FOR ACU K18 SOLAR PUMP FOR POOL Draft projection

47 Connection diagram T7 Basic connection of the THRs boiler cascade (max. 15 boilers) designed for one to three the mixed / direct heating circuits. Or for connecting external appliances with a heat demand signal 0-10 V (optionally ON / OFF), with a possible extension of HW heating in an indirectly heated container by a charging pump (all variants of production priority). Furthermore, the control can be supplemented by HW solar heating. This connection is in terms of wiring implementation better than T6 connection. In this case the cascade master is the regulator LPB LPB LPB 230 V/50 Hz 10 A B2 B2 B2 B7 B7 B7 B9 QAC V/50 Hz 10 A RVS REGULATOR Q1 Q1 Q1 AVS Y3 Y3 Y3 B10 (BX1) CONTROL PANEL B1 (BX3) RADIATORS OR FLOOR HEATING Q4 (QX1) TV Q3 (QX3) Q2 (QX5) Y1/2 (QX2/4) B3 ZV B6 (BX21) B12 Q6 RADIATORS OR FLOOR HEATING 230 V/50 Hz 6 A Q5 (QX23) B31 (BX22) 230 V/50 Hz 6 A Y5/6 AVS EXTENSION MODULE NO. 1 SV ZV AVS EXTENSION MODULE NO. 2 Q15(H1) (QX2) AVS EXTENSION MODULE QAZ HEAT SINK SOLAR QAZ HEAT SINK HW AVS BX21 BX22 B6 B31 VZT REQUIREMENT VZT H1 QX21 QX22 QX23 Q5 ZV 46 Draft projection 2013

48 Condensing boilers THRs RVS to which the appliances are connected. It is located in the switchboard enclosure where you can add control and power switching elements. Boilers are then connected only by a communication twin cable. BASIC REGULATION: 3 - COMMUNICATION INTERFACE LPB RVS EQUITHERMAL REGULATOR AVS CONTROL PANEL QAD36 - CASCADE SETUP B10 QAD36 - CONTACT TO1 RVS QAZ36 - HEAT SINK HW B3 BX1 BX3 BX1 BX3 BX1 BX3 BX1 BX2 BX3 B10 B1 QX1 QX2 QX3 QX4 QX5 Q4 Y1 Q2 Y2 LEGEND B1 SETUP TO1 B12 SETUP TO2 B13 POOL B15 PRE-REGULATION B2 BOILER B22 WOOD BOILER B3 TOP HW B31 BOTTOM HW B39 HW CIRCULATION B4 ACCUMULATION TOP B41 ACCUMULATION BOTTOM B42 ACCUMULATION INTERMEDIATE B6 COLLECTOR B7 RETURN PIPE B70 CASCADE RETURN PIPE B73 COMMON RETURN PIPE B8 COMBUSTION PRODUCTS TEMP. B9 OUTDOOR TEMP. Q1 BOILER PUMP Q2 PUMP TO1 Q3 HW PUMP/VALVE Q4 HW CIRCULATION PUMP Q5 COLLECTOR PUMP Q6 PUMP TO2 Q10 WOOD BOILER PUMP Q11 ACU CHARGING PUMP Q14 FEED PUMP Q15 PUMP H1 Q18 PUMP H2 Q19 PUMP H3 Q20 DIRECT HC PUMP Y1/2 MIXER TO1 Y5/6 MIXER TO2 Y15 RETURN PIPE VALVE Y19/20 PRE-REGULATION VALVE K6 EL. HEATING ELEMENT K8 SOLAR PUMP FOR ACU K18 SOLAR PUMP FOR POOL 3 - COMMUNICATION INTERFACE LPB RVS EQUITHERMAL REGULATOR AVS CONTROL PANEL AVS EXTENSION MODULE QAD36 - CASCADE SETUP B10 QAD36 - CONTACT TO1 QAD36 - CONTACT TO2 QAZ36 - HEAT SINK HW B3 RVS AVS BX1 BX3 BX1 BX3 BX1 BX3 BX1 BX2 BX3 B10 B1 BX21 BX22 B12 QX1 QX2 QX3 QX4 QX5 Q4 Y1 Q3 Y2 Q2 QX21 QX22 QX23 Y5 Y6 Q5 Draft projection

49 Connection diagram T8 The connection of the THRs boiler cascade (max. 16 boilers) designed for one to three mixed / direct heating circuits. Or for connecting external appliances with a heat demand signal 0-10 V (optionally ON / OFF), with a possible extension of HW heating in an indirectly heated container by a switching valve from one boiler (absolute production priority). This connection is suitable for the building with a low HW consumption with regard to the heat loss of the building (for example, office buildings or schools without a canteen). B9 QAC34 LPB BOILER NO. 1 BOILER NO. 2 BOILER NO V/50 Hz 10 A B2 B2 B2 B7 B7 B7 ROOM UNIT QAA55110 ROOM UNIT QAA Q1 Q1 Q1 Y3 B10 (BX1) TV Q4 (QX1) B1 Q2 RADIATORS OR FLOOR HEATING Y1/2 B3 ZV B6 (BX21) B12 Q6 RADIATORS OR FLOOR HEATING B31 (BX22) Q5 (QX23) SV Y5/6 ZV B12 Q6 RADIATORS OR FLOOR HEATING Y5/6 ZV 48 Draft projection 2013

50 Condensing boilers THRs It is always necessary to consider whether the T7 connection is better for the given installation. 3 COMMUNIC. INTERFACE LPB 2 COMMUNIC. INTERFACE LPB - EXTENSION MODULE TO1 QAD36 - CONTACT TO1 QAZ HEAT SINK HW B3 (PART OF THE HW HEATING KIT) 2 - COMMUNICATION INTERFACE LPB - EXTENSION MODULE TO1 - EXTENSION MODULE TO2 QAD36 - CONTACT TO1 QAD36 - CONTACT TO2 QAZ HEAT SINK HW B3 (PART OF THE HW HEATING KIT) QAZ HEAT SINK SOLAR B6 QAZ BOTTOM HW B31 BX1 BX3 BX3 B10 B10 QX1 QX2 QX2 BX1 BX1 BX3 BX3 BX21 BX22 H2 H2 B10 B10 B1 B1 QX1 QX2 QX2 QX21 QX22 QX23 Q4 Q4 Y1 Y1 Y2 Y2 Q2 Q2 BX1 BX1 BX3 BX3 BX21 BX22 H2 H2 B10 B10 B31 B31 B1 B1 B6 B6 BX21 BX22 H2 H2 B12 B12 QX1 QX1 QX2 QX2 QX21QX22 QX22QX23 QX23 QX21QX22 QX22QX23 QX23 Q5 Q5 Q4 Q4 Y1 Y1 Y2 Y2 Q2 Q2 Y5 Y5 Y6 Y6 Q6 Q6 LEGEND B1 SETUP TO1 B12 SETUP TO2 B13 POOL B15 PRE-REGULATION B2 BOILER B22 WOOD BOILER B3 TOP HW B31 BOTTOM HW B39 HW CIRCULATION B4 ACCUMULATION TOP B41 ACCUMULATION BOTTOM B42 ACCUMULATION INTERMEDIATE B6 COLLECTOR B7 RETURN PIPE B70 CASCADE RETURN PIPE B73 COMMON RETURN PIPE B8 COMBUSTION PRODUCTS TEMP. B9 OUTDOOR TEMP. Q1 BOILER PUMP Q2 PUMP TO1 Q3 HW PUMP/VALVE Q4 HW CIRCULATION PUMP Q5 COLLECTOR PUMP Q6 PUMP TO2 Q10 WOOD BOILER PUMP Q11 ACU CHARGING PUMP Q14 FEED PUMP Q15 PUMP H1 Q18 PUMP H2 Q19 PUMP H3 Q20 DIRECT HC PUMP Y1/2 MIXER TO1 Y5/6 MIXER TO2 Y15 RETURN PIPE VALVE Y19/20 PRE-REGULATION VALVE K6 EL. HEATING ELEMENT K8 SOLAR PUMP FOR ACU K18 SOLAR PUMP FOR POOL 2 - COMMUNICATION INTERFACE LPB - EXTENSION MODULE TO1 - EXTENSION MODULE TO2 - EXTENSION MODULE TO3 QAD36 - CONTACT TO1 QAD36 - CONTACT TO2 QAD36 - CONTACT TO3 QAZ HEAT SINK HW B3 (PART OF THE HW HEATING KIT) QAZ HEAT SINK SOLAR B6 QAZ BOTTOM HW B31 BX1 BX1 BX3 BX3 BX21 BX21BX22 BX22 H2 H2 B10 B10 B31 B31 B1 B1 B6 B6 BX21 BX21BX22 BX22 H2 H2 B12 B12 QX1 QX1 QX2 QX2 QX21 QX21QX22 QX22QX23 QX23 QX21 QX21QX22 QX22QX23 QX23 Q5 Q5 Q4 Q4 Y1 Y1 Y2 Y2 Q2 Q2 Y5 Y5 Y6 Y6 Q6 Q6 BX21 BX21BX22 BX22 H2 H2 B14 B14 QX21 QX21QX22 QX22QX23 QX23 Y11 Y11 Y12 Y12 Q20 Q20 Draft projection

51 Connection diagram T9 The connection of the THRs condensing boiler in a trivalent system with one mixed heating circuit, solid fuel boiler, HW solar heating and heating solar support. The connection demonstrates maximum options of the LMS boiler automatic system control unit by using three extension modules without the need for additional RVS regulation. Used hydraulic connection allows both an alternative and bivalent operation of heat sources. It saves the cost of control system but the "all of boilers" is demanding for wiring implementation. It is always necessary to consider whether the T9 connection is better for the given installation. B9 QAC34 BSB 230 V/50 Hz 10 A B2 B7 ROOM UNIT QAA ROOM UNIT QAA RADIATORS EXP Q1 B1 Q2 B10 (BX1) Y1/2 Y15 (QX1) B73 (BX2) ZV Q3 B22 (BX22) B4 (BX21) STORAGE TANK Q10 (QX2) 3 1 B41 (BX22) TV SV SOLID FUEL BOILER ZV 2 B3 B31 (BX21) BIVALENT HW TANK SV 50 Draft projection 2013

52 Condensing boilers THRs B6 (BX22) WEB SERVER OZW V/50 Hz 10 A INTERNET - RJ/45 OPTIONALL Y BX1 BX3 B10 B73 QX1 QX2 Y15 Q10 BX21 BX22 H2 B1 B22 QX21 QX22 QX23 Y1 Y2 Q2 BX21 BX22 H2 B4 B41 QX21 QX22 QX23 Q5 K8 BX21 BX22 H2 B31 B6 QX21 QX22 QX23 HEATING CIRCUIT 1 MULTIFUNCTI ONAL MULTIFUNCTI ONAL LEGEND B1 SETUP TO1 B12 SETUP TO2 B13 POOL B15 PRE-REGULATION B2 BOILER B22 WOOD BOILER B3 TOP HW B31 BOTTOM HW B39 HW CIRCULATION B4 ACCUMULATION TOP B41 ACCUMULATION BOTTOM B42 ACCUMULATION INTERMEDIATE B6 COLLECTOR B7 RETURN PIPE B10 CASCADE SETUP B70 CASCADE RETURN PIPE B73 COMMON RETURN PIPE B8 COMBUSTION PRODUCTS TEMP. B9 OUTDOOR TEMP. Q1 BOILER PUMP Q2 PUMP TO1 Q3 HW PUMP/VALVE Q4 HW CIRCULATION PUMP Q5 COLLECTOR PUMP Q6 PUMP TO2 Q10 WOOD BOILER PUMP Q11 ACU CHARGING PUMP Q14 FEED PUMP Q15 PUMP H1 Q18 PUMP H2 Q19 PUMP H3 Q20 DIRECT HC PUMP Y1/2 MIXER TO1 Y5/6 MIXER TO2 Y15 RETURN PIPE VALVE Y19/20 PRE-REGULATION VALVE K6 EL. HEATING ELEMENT K8 SOLAR PUMP FOR ACU K18 SOLAR PUMP FOR POOL Q5 (QX21) K8 (QX22) Draft projection

53 Connection diagram T10 The connection of the THRs condensing boiler in a trivalent system with one to two heating circuits, solid fuel boiler, HW solar heating and heating solar support. Any pool heating can be performed by solar heating, the main source or by the exhaust of the excess heat of a solid fuel boiler. The connection exceeds maximal options of the LMS boiler automatic system control unit by using three extension module, therefore the additional RVS regulation is used. Used hydraulic connection allows both alternative and bivalent operation of heat sources. B9 QAC V/50 Hz 10 A 230 V/50 Hz 10 A 230 V/50 Hz 10 A REGULATOR LPB RVS AVS AVS ADDRESS LPB 1 ADDRESS SEG 0 EXTENSION MODULE NO. 1 EXTENSION MODULE NO. 2 CONTROL PANEL AVS V/50 Hz 10 A B2 B7 ROOM UNIT QAA ROOM UNIT QAA RADIATORS FLOOR HEATING EXP Q1 B1 Q2 B12 Q6 B10 (BX1) Y1/2 Y5/6 Y15 (QX1) B73 (BX1) ZV ZV Q3 B22 (BX21) B4 (BX2) STORAGE TANK ZV Q10 (QX4) 3 1 B41 (BX3) TV SV SOLID FUEL BOILER ZV 2 B3 B31 (BX21) BIVALENT HW TANK SV 52 Draft projection 2013

54 Condensing boilers THRs Q5 (QX23) K18 (QX3) B6 (BX21) WEB SERVER OZW K8 (QX2) 230 V/50 Hz 10 A INTERNET - RJ/45 OPTIONALL Y Q15 (QX22) RVS BX1 BX2 BX3 BX4 B73 B4 B41 B13 QX1 QX2 QX3 QX4 Y15 K8 K18 Q10 AVS BX21 BX22 B6 B31 QX21 QX22 QX23 Q15 Q5 AVS BX21 BX22 B22 QX21 QX22 QX23 LEGEND B1 SETUP TO1 B12 SETUP TO2 B13 POOL B15 PRE-REGULATION B2 BOILER B22 WOOD BOILER B3 TOP HW B31 BOTTOM HW B39 HW CIRCULATION B4 ACCUMULATION TOP B41 ACCUMULATION BOTTOM B42 ACCUMULATION INTERMEDIATE B6 COLLECTOR B7 RETURN PIPE B10 CASCADE SETUP B70 CASCADE RETURN PIPE B73 COMMON RETURN PIPE B8 COMBUSTION PRODUCTS TEMP. B9 OUTDOOR TEMP. Q1 BOILER PUMP Q2 PUMP TO1 Q3 HW PUMP/VALVE Q4 HW CIRCULATION PUMP Q5 COLLECTOR PUMP Q6 PUMP TO2 Q10 WOOD BOILER PUMP Q11 ACU CHARGING PUMP Q14 FEED PUMP Q15 PUMP H1 Q18 PUMP H2 Q19 PUMP H3 Q20 DIRECT HC PUMP Y1/2 MIXER TO1 Y5/6 MIXER TO2 Y15 RETURN PIPE VALVE Y19/20 PRE-REGULATION VALVE K6 EL. HEATING ELEMENT K8 SOLAR PUMP FOR ACU K18 SOLAR PUMP FOR POOL ZV Q15 K18 (QX22) (QX3) FILTRATION B13 (BX4) Draft projection

55 UNIVENTA PTY LTD P.O.Box 6233, NARRAWEENA NSW Web:

Control Products & Systems OEM

Control Products & Systems OEM LMS The modular management system for condensing boilers Control Products & Systems OEM www.siemens.com/buildingtechnologies-oem LMS advanced electronics and proven software At times of dwindling resources,

More information

Control Products & Systems OEM

Control Products & Systems OEM Matching components for heating boilers Control Products & Systems OEM www.siemens.com/buildingtechnologies-oem Optimum system solutions for enhanced room comfort Using decades of experience in the field

More information

RVS43.. RVS63.. AVS75.. AVS37.. QAA75.. QAA78.. QAA55.. Albatros2 Boiler controllers User manual. Building Technologies HVAC Products

RVS43.. RVS63.. AVS75.. AVS37.. QAA75.. QAA78.. QAA55.. Albatros2 Boiler controllers User manual. Building Technologies HVAC Products Albatros2 Boiler controllers User manual Edition 2.0 Controller series B CE1U2354en 11. May 2007 RVS43.. RVS63.. AVS75.. AVS37.. QAA75.. QAA78.. QAA55.. Building Technologies HVAC Products 2/156 HVAC Products

More information

Sirius FS. Working towards a cleaner future

Sirius FS. Working towards a cleaner future Sirius FS Floor Standing Stainless Steel Condensing Boilers Single Boiler Applications: 50 to 160kW Modular Boiler Applications: up to 640kW Working towards a cleaner future heating specialists 1. Product

More information

ProCon 16, 31, 47 & 75. RVA 63 Boiler and Circuit Controller Commissioning Data.

ProCon 16, 31, 47 & 75. RVA 63 Boiler and Circuit Controller Commissioning Data. ProCon 16, 31, 47 & 75. RVA 63 Boiler and Circuit Controller Commissioning Data. The RVA63 controller can be utilized to control the following system configurations via LPB communication. Equipment Required

More information

RVS43.. RVS63.. AVS75.. AVS37.. QAA75.. QAA78.. QAA55.. Albatros2 Boiler controller User Manual. Building Technologies HVAC Products

RVS43.. RVS63.. AVS75.. AVS37.. QAA75.. QAA78.. QAA55.. Albatros2 Boiler controller User Manual. Building Technologies HVAC Products Albatros2 Boiler controller User Manual Edition 3.0 Controller series B CE1U2354en 23. August 2007 RVS43.. RVS63.. AVS75.. AVS37.. QAA75.. QAA78.. QAA55.. Building Technologies HVAC Products 2/180 HVAC

More information

Heating and D.h.w. Controller RVL482 Basic Documentation

Heating and D.h.w. Controller RVL482 Basic Documentation Heating and D.h.w. Controller RVL482 Basic Documentation Edition: 1.0 Controller series: A CE1P2542en 20.05.2008 Building Technologies Siemens Switzerland Ltd Building Technologies Group International

More information

The competent brand for energy saving systems NEW. Gas-combi boiler CGG-1K-24/28

The competent brand for energy saving systems NEW. Gas-combi boiler CGG-1K-24/28 The competent brand for energy saving systems NEW Gas-combi boiler CGG-1K-24/28 Gas-combi boiler CGG-1K Technical data room sealed fannned flue model gas combi boiler for low temperature heating and d.h.w.

More information

Sirius WH. Working towards a cleaner future

Sirius WH. Working towards a cleaner future Sirius WH Wall Hung Stainless Steel Condensing Boilers Single Boiler Applications: 50 to 110kW Modular Boiler Applications: up to 880kW Working towards a cleaner future heating specialists 1. Product Overview

More information

ProCon Boiler Controller Commissioning Quick Reference Guide

ProCon Boiler Controller Commissioning Quick Reference Guide ProCon Boiler Controller Commissioning Quick Reference Guide This sheet is intended as a quick reference guide and should be read in conjunction with the operating and maintenance manual for the boiler

More information

RVA /109. Heating Circuit ZONE Controller. Instructions for the INSTALLER

RVA /109. Heating Circuit ZONE Controller. Instructions for the INSTALLER Heating Circuit ZONE Controller RVA 46.531/109 Zonal temperature controller for control of a lowtemperature heating system, for use with condensing gas boilers Instructions for the INSTALLER INDEX Page

More information

RVS46.. AVS75.. AVS37.. QAA75.. QAA78.. QAA55.. Albatros 2 Zone controller User Manual. Building Technologies HVAC Products

RVS46.. AVS75.. AVS37.. QAA75.. QAA78.. QAA55.. Albatros 2 Zone controller User Manual. Building Technologies HVAC Products Albatros 2 Zone controller User Manual RVS46.. AVS75.. AVS37.. QAA75.. QAA78.. QAA55.. Edition 3.0 @@@@ CE1U2353en 02.06.2009 Building Technologies HVAC Products 2/135 HVAC Products 02.06.2009 Contents

More information

Stainless steel range of condensing boilers. Designed to meet carbon reduction targets. Lifetime service and support. Outputs from 50kW to 660kW

Stainless steel range of condensing boilers. Designed to meet carbon reduction targets. Lifetime service and support. Outputs from 50kW to 660kW Stainless steel range of condensing boilers Outputs from 50kW to 660kW Designed to meet carbon reduction targets Lifetime service and support Totally dependable. page 1 www.pottertoncommercial.co.uk Contents

More information

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support Aluminium range of condensing boilers Outputs from 30kW to 600kW Designed to meet carbon reduction targets Lifetime service and support Works every time. www.pottertoncommercial.co.uk Aluminium range of

More information

RVS13... RVS53... AVS75... AVS37... QAA75... QAA78... QAA55... Albatros2 Boiler controllers User Manual. Building Technologies HVAC Products

RVS13... RVS53... AVS75... AVS37... QAA75... QAA78... QAA55... Albatros2 Boiler controllers User Manual. Building Technologies HVAC Products lt o V.5 1 2 0 N O Albatros2 Boiler controllers User Manual Edition 2.1 Controller series B CE1U2357en 6. July 2006 RVS13... RVS53... AVS75... AVS37... QAA75... QAA78... QAA55... Building Technologies

More information

WOLF GAS CONDENSING BOILERS COMFORTLINE

WOLF GAS CONDENSING BOILERS COMFORTLINE WOLF GAS CONDENSING BOILERS COMFORTLINE CGB-35/50 / CGB-75/100 30m 3 /h THE EXTENSIVE EQUIPMENT RANGE from system supplier WOLF offers the ideal solution for commercial and industrial buildings, new build

More information

ProCon 16, 31, 47, 75, 77 & HT. RVA 46. Zone Controller Commissioning Data.

ProCon 16, 31, 47, 75, 77 & HT. RVA 46. Zone Controller Commissioning Data. ProCon 16, 31, 47, 75, 77 & HT. RVA 46. Zone Controller Commissioning Data. The RVA 46 Zone Controller can only be used in conjunction with a RVA47 controlled boiler installation. The RVA46 controller

More information

Superior. A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler. Outputs 120, 160, 200, 240, 280 kw

Superior. A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler. Outputs 120, 160, 200, 240, 280 kw Superior A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler Outputs 120, 160, 200, 240, 280 kw 1 The Superior is a, pre-assembled floor standing, gas fired high efficiency

More information

Type summary Albatros 2

Type summary Albatros 2 OEM Type summary lbatros 2 The lbatros 2 family is a comprehensive range of controls. It offers solutions for basic to complex heating plant. Uniform and integral operating philosophy with clear-text display

More information

RVL481. Heating Controller. including d.h.w. heating

RVL481. Heating Controller. including d.h.w. heating 2 541 Heating Controller including d.h.w. heating RVL481 Multifunctional and communicating heating controller for use in residential and non-residential buildings. Suited for heating circuit control with

More information

1 VICTRIX ZEUS Superior kw I features

1 VICTRIX ZEUS Superior kw I features Wall-hung condensing VICTRIX ZEUS Superior kw I is the new range of wall-hung condensing boilers with 54 litre stainless steel storage tank available in two versions with nominal heat output of 26 kw and

More information

HIGH OUTPUT. Skin design RANGE

HIGH OUTPUT. Skin design RANGE Light drop design HIGH OUTPUT Skin design RANGE Trim design 1 Product Introduction Product Presence Worlwide 2 Product Presentation Bosch Model Commercial Name: GWHC 27 3 Product Presentation Product Design

More information

RVL472. Heating Controller. Building Technologies HVAC Products. Series C. including d.h.w. heating

RVL472. Heating Controller. Building Technologies HVAC Products. Series C. including d.h.w. heating 2 526 Heating Controller including dhw heating Series C RVL472 Multifunctional heating controller for use in residential and non-residential buildings Suited for: Heating zone control with or without room

More information

RVL471 Heating and Domestic Hot Water Controller Basic Documentation

RVL471 Heating and Domestic Hot Water Controller Basic Documentation RVL471 Heating and Domestic Hot Water Controller Basic Documentation Edition: 2.2 Controller series: C CE1P2524E 23.10.2002 Siemens Building Technologies HVAC Products 2/118 HVAC Products 23.10.2002 Contents

More information

Gas condensing boiler (wall mounted) TopGas

Gas condensing boiler (wall mounted) TopGas Gas condensing boiler (wall mounted) TopGas Modern gas condensing technology generates up to 15 % more heat from the consumed energy source. TopGas. Advanced technology attractive and compact. TopGas.

More information

Rapid. Suspended Warm Air Heater. Caring for the environment!

Rapid. Suspended Warm Air Heater. Caring for the environment! Rapid Suspended Warm Air Heater Caring for the environment! RAPID The QUICK and ECOLOGICAL Suspended Heater Our RAPID heaters were conceived and designed for the heating of industrial and commercial buildings.

More information

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support Aluminium range of condensing boilers Outputs from 30kW to 600kW Designed to meet carbon reduction targets Lifetime service and support Works every time. www.pottertoncommercial.co.uk Aluminium range of

More information

RVL470. Heating Controller. Use. Functions. Series B

RVL470. Heating Controller. Use. Functions. Series B 2 522 Heating Controller Series B RVL470 Multifunctional heating controller for use in residential and non-residential buildings; suitable for weather-dependent flow temperature control of heating zones

More information

Description of the. controllers. Description of the. system extension possibilities. RS communication. Front panel made of glass. Control of 2 valves

Description of the. controllers. Description of the. system extension possibilities. RS communication. Front panel made of glass. Control of 2 valves Description of the controllers Control of 2 valves Control of 3 valves Front panel made of glass Touchscreen Wireless communication Wired communication Update via USB Uploading photos via USB Control of

More information

ENERGY TOP. Condensing boiler solutions

ENERGY TOP. Condensing boiler solutions ENERGY TOP Condensing boiler solutions 1 ENERGY TOP > ENERGY TOP RANGE A wide array of flexible solutions both for centralised residential application and big commercial plants The increasing need for

More information

HIGH-POWER HEAT PUMPS. Up to 300 kw

HIGH-POWER HEAT PUMPS. Up to 300 kw HIGH-POWER HEAT PUMPS Up to 300 kw 1 2 NEW GENERATION OF HEAT PUMPS GORENJE 4 COMPLETE RANGE OF NEW GENERATION HIGH-POWER HEAT PUMPS 8 MODERN CONTROL UNIT HEAT PUMPS AIR-WATER 10 Heat pumps AEROGOR COMPACT

More information

PE1 Pellet. PE1 Pellet. Pellet boiler - Canada. PE1 Pellet APPROVED FOR EPA 2020 EMISSION LIMITS.

PE1 Pellet. PE1 Pellet. Pellet boiler - Canada. PE1 Pellet APPROVED FOR EPA 2020 EMISSION LIMITS. PE1 Pellet PE1 Pellet Pellet boiler - Canada PE1 Pellet Awarded the APPROVED FOR EPA 2020 EMISSION LIMITS Austrian Ecolabel! www.froeling.com 1 Heating with pellets For more than 50 years Froling has specialised

More information

RMG MK. II RMG Mk.II RS Mk.II RMG Mk.II RS Mk.II

RMG MK. II RMG Mk.II RS Mk.II RMG Mk.II RS Mk.II Caldaie a basamento RMG Mk.II and RS Mk.II gas boilers are cast-iron made and are developed and manufactured in order to meet the demands of heating installations of middle and high output, thanks to the

More information

Main Features. Functions. with automatic ignition and control functions for the heating and domestic hot water circuit

Main Features. Functions. with automatic ignition and control functions for the heating and domestic hot water circuit 7 618 Gas Burner Controls with automatic ignition and control functions for the heating and domestic hot water circuit ISO 9001 Microprocessor-based gas burner controls providing all control functions

More information

Digital Electronic Thermostat With RF

Digital Electronic Thermostat With RF RT300RF Manual:89 6/7/10 12:52 Page 1 Digital Electronic Thermostat With RF Instruction Manual Model No RT300RF 2 RT300RF Manual:89 6/7/10 12:52 Page 2 2 RT300RF INSTRUCTION MANUAL RT300RF Manual:89 6/7/10

More information

So old fashioned... As the combustion chamber is completely room sealed, it does not release any smells and does not dirty.

So old fashioned... As the combustion chamber is completely room sealed, it does not release any smells and does not dirty. ARREDO E BENESSERE So old fashioned... An intelligent choice When on a cold winters night the warm glowing flames of the KALDUS boiler are there to welcome you back home, you will be pleased that you decided

More information

TopGas Wall Hung Condensing Gas Boiler

TopGas Wall Hung Condensing Gas Boiler TopGas Wall Hung Condensing Gas Boiler Output range 30 to 80 kw Why choose TopGas? TopGas wall-hung boilers offer compact and advanced gas heating technology built to the high quality standards you would

More information

Technical description. Atec.

Technical description. Atec. www.thermia.com Thermia Värmepumpar is not liable or bound by warranty if these instructions are not adhered to during installation or service. The English language is used for the original instructions.

More information

ALKON CARGO. A precise and fast delivery rate. A very high specific flow rate (20 litres per minute with Dt 25)

ALKON CARGO. A precise and fast delivery rate. A very high specific flow rate (20 litres per minute with Dt 25) ALKON CARGO ALKON CARGO model Max/min nominal output Heat input condensing Non-condensing η condensation at 30 part load 35 7,4 35,1 6,7 33,5 34,8 106,3 Efficiency class (directive 92/42) ALKON CARGO is

More information

Manual & Technical Documentation V1.1

Manual & Technical Documentation V1.1 Manual & Technical Documentation V1.1 tado Smart Thermostat tado Extension Kit ENGLISH Content Product Packages Compatibility Intelligence & Security Functions Smart Thermostat Usage Menu Structure Special

More information

Weishaupt WG10 and WG20 gas burners LN (Low NO x ) version 2/2002 CA

Weishaupt WG10 and WG20 gas burners LN (Low NO x ) version 2/2002 CA Weishaupt WG0 and WG20 gas burners LN (Low NO x ) version 2/2002 CA New W series capacity range The Weishaupt WG0 and WG20 gas burners join the WG5, WG30 and WG40 to complete the line-up of products successfully

More information

Knürr RMS Compact II. Knürr RMS Compact II 2.81

Knürr RMS Compact II. Knürr RMS Compact II 2.81 Knürr RMS Compact II Knürr RMS Compact II 2.82 to 2.85 2.81 Knürr RMS Compact II Damage prevention with checks and controls System and network management requirements mean the systems ambient conditions

More information

Digital Electronic Thermostat With RF

Digital Electronic Thermostat With RF Digital Electronic Thermostat With RF Instruction Manual Model No RT300RF PRODUCT COMPLIANCE This product complies with the essential requirements of the following EC Directives: Electro-Magnetic Compatibility

More information

RVL480. Heating Controller

RVL480. Heating Controller 2 540 Heating Controller RVL480 Multifunctional and communicating heating controller for use in residential and non-residential buildings. Suited for heating circuit control, boiler temperature control

More information

Room Units and Sensors for Use in Heating Plants. Siemens Building Technologies HVAC Products SIGMAGYR. Type summary

Room Units and Sensors for Use in Heating Plants. Siemens Building Technologies HVAC Products SIGMAGYR. Type summary 2 401 SIGMAGYR Room Units and Sensors for Use in Heating Plants Type summary Sensors and room units with PPS interface: QAA24, QAA64, QAA10, QAW50..., QAW70, QAW59x, QAC22, QAC32, QAD22, QAD26, QAE22,

More information

Electronic controllers. Comfort embellishes everyday life

Electronic controllers. Comfort embellishes everyday life Electronic controllers Comfort embellishes everyday life Comfort and security Comfort embellishes everyday life An electronic blind controller from Schenker Storen brings added value, however, it is anything

More information

Great Britain en. Installation, user and service manual. Control panel HMI Gas 310/610 ECO PRO

Great Britain en. Installation, user and service manual. Control panel HMI Gas 310/610 ECO PRO Great Britain en Installation, user and service manual Control panel HMI Gas 310/610 ECO PRO Dear Customer, Thank you very much for buying this appliance. Please read through the manual carefully before

More information

WALL HUNG GAS BOILER FOR C.H. AND PREDISPOSTION FOR INSTANTANEOUS D.H.W. PRODUCTION (with optional kit) MODELS 34,8 kw (depotenziata) 50 C

WALL HUNG GAS BOILER FOR C.H. AND PREDISPOSTION FOR INSTANTANEOUS D.H.W. PRODUCTION (with optional kit) MODELS 34,8 kw (depotenziata) 50 C ALKON 50 C ALKON 70 C WALL HUNG GAS BOILER FOR C.H. AND PREDISPOSTION FOR INSTANTANEOUS D.H.W. PRODUCTION (with optional kit) OUTPUT RANGE from 50 to 560 kw (in battery) WORKING TEMPERATURE no limit on

More information

1 DOCUMENT REVISION CONTROL ELEMENTS... 9

1 DOCUMENT REVISION CONTROL ELEMENTS... 9 CONTENTS Contents 1 DOCUMENT REVISION... 8 2 SOFTWARE VERSION... 8 3 BASIC DESCRIPTION... 8 4 CONTROL ELEMENTS... 9 4.1 BASIC DISPLAYS...10 4.2 CONTROL KEYS...11 4.2.1 Rotary button (Press / Turn)...11

More information

VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power

VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power VICTRIX 90 is the new wall-hung condensing boiler for room heating only, set-up for independent functioning and for that in cascade mode

More information

Albatros2 Boiler Controllers User Manual RVS13.. RVS53.. Siemens Schweiz AG HVAC Products. Edition 1.0 Controller series A CE1P2383en

Albatros2 Boiler Controllers User Manual RVS13.. RVS53.. Siemens Schweiz AG HVAC Products. Edition 1.0 Controller series A CE1P2383en Albatros2 Boiler Controllers User Manual Edition 1.0 Controller series A CE1P2383en 01.05.12005 RVS13.. RVS53.. Siemens Schweiz AG HVAC Products 2/89 HVAC Products 6. June 2005 Contents 1 Summary...7 1.1

More information

Gas-Fired Condensing Boilers A Green Start To Space & Water Heating

Gas-Fired Condensing Boilers A Green Start To Space & Water Heating Gas-Fired Condensing Boilers A Green Start To Space & Water Heating Residential space and water heating boiler solutions with up to 98.7% efficiency and 57.2 to 151.6 MBH inputs. 1 New! Bosch residential

More information

Gas condensing boiler UltraGas

Gas condensing boiler UltraGas Gas condensing boiler UltraGas Patented alufer for a high efficiency and low emission. 1 UltraGas (15-90) and (125-2000D). Advantages at a glance. The UltraGas condensing boiler with patented alufer heat

More information

ADI LT CONDENSING LOW TEMPERATURE BOILER

ADI LT CONDENSING LOW TEMPERATURE BOILER ADI LT CONDENSING LOW TEMPERATURE BOILER TECHNICAL MANUAL OF INSTALLATION, USE AND MAINTENANCE V. 07/2017 INDEX 1. INTRODUCTION 4 2. REGULATIONS 5 3. EEC APPROVALS AND CERTIFICATIONS 5 4. BOILER GENERAL

More information

5 YEAR GUARANTEE. Inovia. High efficiency condensing combi and system boilers

5 YEAR GUARANTEE. Inovia. High efficiency condensing combi and system boilers * 5 YEAR GUARANTEE Inovia High efficiency condensing combi and system boilers WALL HUNG BOILERS Inovia INOVIA HIGH EFFICIENCY BOILER RANGE The Inovia range is the latest in intelligent gas boiler technology

More information

THERMAX Efficiency Monitor

THERMAX Efficiency Monitor INSTALLATION & OPERATION INSTRUCTIONS THERMAX Efficiency Monitor Oil & Gas Fired Heating Equipment Efficiency Monitoring Instrument Important Safety Instructions Read and safe these instructions before

More information

Underfloor Catalogue Heating products that define the market

Underfloor Catalogue Heating products that define the market YEAR 5 WARRANTY Underfloor Catalogue Heating products that define the market By Underfloor Heating Control We provide a range of room temperature controls (thermostats) to optimize the operating efficiency

More information

NEW. Innovative heating controls. Commercial boiler control systems. Control 8000 & MX25

NEW. Innovative heating controls. Commercial boiler control systems. Control 8000 & MX25 Innovative heating controls NEW Commercial boiler control systems Control 8000 & MX25 2 Everything perfectly under control About the Bosch Group Leading global supplier The Bosch Group is active in the

More information

your tree NEW TREE for you Several facts on trees: Follow our Green Tree heat pumps

your tree NEW TREE  for you Several facts on trees: Follow our Green Tree heat pumps Follow our Green Tree heat pumps heat pumps manufacturer Green Join the Hotjet Green Tree your tree for you Line project, let us plant By purchasing the first heat pump in the HOTJET Green Tree product

More information

OPERATION MANUAL RK-2006LPP AUGER FITTED SOLID FUEL BOILER TEMPERATURE CONTROLLER. Version DC19

OPERATION MANUAL RK-2006LPP AUGER FITTED SOLID FUEL BOILER TEMPERATURE CONTROLLER. Version DC19 OPERATION MANUAL RK-2006LPP AUGER FITTED SOLID FUEL BOILER TEMPERATURE CONTROLLER Version DC19 1. Application. Controller RK-2006LPP is designed for temperature control of solid fuel fired water boilers

More information

5 YEAR ADVANCE PLUS WARRANTY. High efficiency condensing combi and system boilers

5 YEAR ADVANCE PLUS WARRANTY. High efficiency condensing combi and system boilers 5 YEAR WARRANTY ADVANCE PLUS High efficiency condensing combi and system boilers Android Apple WALL HUNG BOILERS Advance Plus ADVANCE PLUS HIGH EFFICIENCY BOILER RANGE The Advance Plus range is the latest

More information

Heating is great when you control it. USER MANUAL. Wireless Programmable Room Thermostat. Model No.: LS Scan for App

Heating is great when you control it. USER MANUAL. Wireless Programmable Room Thermostat. Model No.: LS Scan for App Heating is great when you control it. USER MANUAL Wireless Programmable Room Thermostat Model No.: LS99111010 Scan for App Contents 1. Overview... 01 2. System Installation... 02 2.1 Install and Wiring

More information

Tank systems. Layered tank Solar layered tank Hygienic layered tank Modular layered tank Hot water tank NEW:

Tank systems. Layered tank Solar layered tank Hygienic layered tank Modular layered tank Hot water tank NEW: Tank systems Layered tank Solar layered tank Hygienic layered tank Modular layered tank Hot water tank NEW: NEOPOR AND FLEECE INSULATION SENSOR TERMINAL STRIP ADJUSTABLE FEET www.froeling.com Energy management

More information

FCX FUEL OIL CONDENSING BOILER RANGE

FCX FUEL OIL CONDENSING BOILER RANGE FCX FUEL OIL CONDENSING BOILER RANGE BOILERS FUEL OIL, CONDENSING CHIMNEY OR BALANCED FLUE HEATING ONLY DOMESTIC HOT WATER OPTIONS OUTPUT 22.3 kw or 30.5 kw Why choose a Geminox boiler? To benefit from

More information

M116 / M450 USER AND MAINTENANCE MANUAL FOR MODULATING-CONTROL BOILER WITH GAS BURNER EQUIPPED FOR NATURAL GAS. Type : B23 ATLANTIC 2000

M116 / M450 USER AND MAINTENANCE MANUAL FOR MODULATING-CONTROL BOILER WITH GAS BURNER EQUIPPED FOR NATURAL GAS. Type : B23 ATLANTIC 2000 M SERIES M116 / M45 USER AND MAINTENANCE MANUAL FOR MODULATING-CONTROL BOILER WITH GAS BURNER EQUIPPED FOR NATURAL GAS Type : B23 Country BE CH ES FR GB IE IT LU NL PT Category I2E(R)B I2H I2H I2Esi I2H

More information

Floor standing boilers. RMG Mk.II RS Mk.II

Floor standing boilers. RMG Mk.II RS Mk.II Floor standing boilers RMG Mk.II RS Mk.II Caldaie a basamento RMG Mk.II - RS Mk.II The perfect solution for modular combinations RMG Mk.II and RS Mk.II gas boilers are cast-iron made and are developed

More information

Ion Gateway Cellular Gateway and Wireless Sensors

Ion Gateway Cellular Gateway and Wireless Sensors Page 1 of 9 Account & Network Setup If this is your first time using the Ion Gateway online system site you will need to create a new account. If you have already created an account you can skip to the

More information

RVP360 and RVP361 Heating controllers for 2 heating circuits and d.h.w. Basic Documentation

RVP360 and RVP361 Heating controllers for 2 heating circuits and d.h.w. Basic Documentation RVP360 and RVP361 Heating controllers for 2 heating circuits and d.h.w. Basic Documentation Edition 1.0 Controller series A CE1P2546en 15.03.2011 Building Technologies Siemens Switzerland Ltd Industry

More information

PROMATIC WDC Heating controllers Energy under control

PROMATIC WDC Heating controllers Energy under control www.seltron.eu 205 PROMATIC WDC Heating controllers Energy under control 36 Made for warmth. PROMATIC WDC Heating controllers 37 PROMATIC WDC Heating controllers HIGHLIGHTS ycontrol of up to 52 different

More information

FAMILY PRO SIMPLY THE BEST

FAMILY PRO SIMPLY THE BEST FAMILY PRO SIMPLY THE BEST RIELLO PROUDLY PRESENTS THE FAMILY PRO LEADING TECHNOLOGY The FAMILY PRO range of condensing boilers has been created with an electronically advanced control system. Riello leads

More information

ADI CD CONDENSING BOILER

ADI CD CONDENSING BOILER ADI CD CONDENSING BOILER º TECHNICAL MANUAL OF INSTALLATION, USE AND MAINTENANCE V. 07/2017 1 INDEX 1. INTRODUCTION 4 2. REGULATIONS 5 3. EEC APPROVALS AND CERTIFICATIONS 5 4. BOILER GENERAL VIEW: DESCRIPTION

More information

COMPACT VENTILATION UNITS DUPLEX R5

COMPACT VENTILATION UNITS DUPLEX R5 EN COMPACT VENTILATION UNITS DUPLEX R5 2016 2018 A COMPANY HISTORY ATREA PRODUCTS ATREA was founded in 1990 in Jablonec nad Nisou in the Czech Republic as a purely family company. Even today, it still

More information

INSTRUCTION FOR THE USER THC V E OIL BLU

INSTRUCTION FOR THE USER THC V E OIL BLU INSTRUCTION FOR THE THC V E OIL BLU CONTENTS General safety information 4 Precautions 4 Control panel 5 Mode selection 8 User levels 10 Start-up 12 Temporary shutdown 15 Preparing for extended periods

More information

EW 40 Wireless Fan Control

EW 40 Wireless Fan Control Installation & Operating Manual EW 40 Wireless Fan Control USA CAN Product Information... Chapters 1 + 2 Mechanical Installation... Chapter 3 Electrical Installation... Chapter 4 Start Up and Configuration...

More information

Master devices. Type X-AIR-ZMAS. Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems

Master devices. Type X-AIR-ZMAS. Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems X X testregistrierung Type Web server, also for mobile devices Zone modules Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems X-AIRCONTROL zone

More information

Fonte Lx NEW. Instantaneus Gas Water Heaters, conventional flue, low NOx. Residential Heating. compliant. Fonte Lx 14. Fonte Lx 11

Fonte Lx NEW. Instantaneus Gas Water Heaters, conventional flue, low NOx. Residential Heating. compliant. Fonte Lx 14. Fonte Lx 11 Fonte Lx Instantaneus Gas Water Heaters, conventional flue, low NOx NEW Residential Heating XL M compliant Fonte Lx 14 Fonte Lx 11 FONTE Lx / Gas Water Heaters, conventional flue, low NOx THE RANGE FONTE

More information

C-Stat 17-ZW User Instructions

C-Stat 17-ZW User Instructions C-Stat 17-ZW User Instructions 7 Day Wireless Programmable Room Thermostat and ASR-ZW Receiver Programmable room thermostats are widely recognised as one of the best ways in which to control central heating.

More information

PCH/new Series. High performance, total flexibility

PCH/new Series. High performance, total flexibility PCH/new Series High performance, total flexibility PCH/new Installation in Air Handling Unit Very Low Emissions NOx lower than 30 ppm : Class 5 Capacity Range 14 models from 5 kw to 400kW Automatic Control

More information

Instruction manual. Remote control electric IR HEATER

Instruction manual. Remote control electric IR HEATER Instruction manual Remote control electric IR HEATER battery consumption rate hour temperature (preset or measured) current operation mode (e.g. comfort) current day heating activated buttons for adjustment

More information

District heating controller for two heating circuits and d.h.w. according to Siemens specifications:

District heating controller for two heating circuits and d.h.w. according to Siemens specifications: 4 319 2984 0 G2384en en Installation Instructions District heating controller for two heating circuits and d.h.w. RVD240 Installation Place of installation In a dry room, e.g. in the heat exchanger room

More information

Ciao Green Condensing Wall-Hung Boilers

Ciao Green Condensing Wall-Hung Boilers Ciao Green Condensing Wall-Hung Boilers Residential Heating Ciao Green A cost-consciuos condensing boiler CIAO GREEN is one of the condensing boilers with the best price-quality ratio on the matket. Kitchen

More information

Efficient heating that won t cost the earth

Efficient heating that won t cost the earth Product Range Guide Efficient heating that won t cost the earth CTC is an international manufacturer of innovative renewable heating solutions. For over 90 years our ranges of high performance products

More information

ALKON 90 ALKON 90 MODEL 24,0 93,6 21,1 87, nominal heat output. conventional. max/min heat input. efficiency class (Directive 92/42)

ALKON 90 ALKON 90 MODEL 24,0 93,6 21,1 87, nominal heat output. conventional. max/min heat input. efficiency class (Directive 92/42) ALKON 90 ALKON 90 MODEL max/min condensing nominal heat output conventional max/min heat input efficiency class (Directive 92/42) kw kw kw ALKON 90 24,0 93,6 21,1 87,5 22-90 Moving in the present with

More information

HDG K SERIES. Wood pellet boiler. The perfect alternative to fossil fuels. Receive up to

HDG K SERIES. Wood pellet boiler.   The perfect alternative to fossil fuels. Receive up to (56.81) April 2013 Receive up to 2635 RHI back every year for the next seven years HDG K SERIES Wood pellet boiler The perfect alternative to fossil fuels www.euroheat.co.uk The K Series pellet boiler,

More information

Synco-GAMMA Application Guide. School building class room. Answers for infrastructure.

Synco-GAMMA Application Guide. School building class room. Answers for infrastructure. Synco- Application Guide School building class room Answers for infrastructure. More efficiency in schools with Synco and building control Requirements Single source Objective of this document School

More information

RVL479. Heating Controller. for use with a partner unit

RVL479. Heating Controller. for use with a partner unit 2 543 Heating Controller for use with a partner unit RVL479 Communicating heating controller for use in residential and non-residential buildings. For exclusive use on the bus together with heating controllers

More information

AVIO kw Export 1 FEATURES. Wall-mounted with storage tank

AVIO kw Export 1 FEATURES. Wall-mounted with storage tank 1 FEATURES Wall-mounted with storage tank Compact wall-mounted open chamber boiler with conventional flue and 45 litre stainless steel storage tank and nominal heat output of 23.7 kw (20,382 kcal/h). AVIO

More information

PRELIMINARY EDITION

PRELIMINARY EDITION 3 131 PRELIMINARY EDITION 14.01.2003 Synco 700 Heating Controllers Heating controller for medium-size and large buildings. The is used as a heating circuit or primary controller. The controller is supplied

More information

VIESMANN. Installation and service instructions VITOTROL 200 RF. for contractors. Vitotrol 200 RF. Wireless remote control for one heating circuit

VIESMANN. Installation and service instructions VITOTROL 200 RF. for contractors. Vitotrol 200 RF. Wireless remote control for one heating circuit Installation and service instructions for contractors VIESMANN Vitotrol 200 RF Wireless remote control for one heating circuit For applicability, see the last page VITOTROL 200 RF 3/2011 Please keep safe.

More information

Control Application. Supplement - ACVMax

Control Application. Supplement - ACVMax prestige Control Application Supplement - ACVMax L I S T E D WARNING This document is intended to be used by a factory trained and qualified heating contractor or service technician only. Read all instructions

More information

Healthy. Atmosphere. for Pigs and Poultry. for a

Healthy. Atmosphere. for Pigs and Poultry. for a Healthy Atmosphere for Pigs and Poultry for a m e t s y s Your Climate ll requirements Alarm Energy Our new 3G product range for a healthy climate in stables for pigs and poultry! The 3G product range

More information

VICTRIX 50 1 SPECIFICATIONS. Wall mounted condensing boilers

VICTRIX 50 1 SPECIFICATIONS. Wall mounted condensing boilers Wall mounted condensing boilers VICTRIX 50 is the new wall-mounted central heating condensing boiler. It is pre-arranged for single and cascade operation (up to 3 appliances connected), with the advantage

More information

District heating controller

District heating controller 2 515 District heating controller for 2 heating circuits and d.h.w., communicating RVD260 Multifunctional heating controller for district heat transfer stations and plants with LPB and M-bus communication.

More information

Room sealed circuit appliance sold without the terminal or the combustion air supply and exhausted gas ducts. TYPE C 63 TYPE B TYPE B 23

Room sealed circuit appliance sold without the terminal or the combustion air supply and exhausted gas ducts. TYPE C 63 TYPE B TYPE B 23 Room sealed circuit appliance sold without the terminal or the combustion air supply and exhausted gas ducts. TYPE C 63 TYPE B Type B 23 on the wall Ø 80 duct, available in the following lengths: 1000,

More information

LFE50. UV Flame Safeguard. Building Technologies Division DETACTOGYR

LFE50. UV Flame Safeguard. Building Technologies Division DETACTOGYR 7 783 DETACTOGYR Flame Safeguard The... together with the QRA50M / QRA51M form a self-checking flame supervision system (DETACTOGYR ) designed for use with continuously operating oil or gas burners or

More information

Seradens Super Seradens Super Plus

Seradens Super Seradens Super Plus Premix Full Condensing Combi Boilers Seradens Super Seradens Super Plus 20-28 - 36 kw THE FIRST CONDENSING TECHNOLOGY BOTH IN HEATING AND DOMESTIC HOT WATER IN TURKEY Smaller, more elegant and efficient

More information

Smart temperature control solutions

Smart temperature control solutions Smart temperature control solutions State-of-the-art heating and cooling solutions, expertise & know-how combined with top quality and superior customer service. 1 1 8 7 5 9 6 10 4 3 2 www.vexve.com Contents

More information

Technical documentation. ComfortLine gas condensing boilers CGB-2(K) CGW-2 CGS-2 CSZ-2 NEW

Technical documentation. ComfortLine gas condensing boilers CGB-2(K) CGW-2 CGS-2 CSZ-2 NEW Technical documentation ComfortLine gas condensing boilers CGB-2(K) CGW-2 CGS-2 CSZ-2 NEW ComfortLine gas condensing boilers Benefits of the WOLF gas condensing boilers up to 24 kw CGB-2(K) / CGW-2 / CGS-2

More information

Power Flame Incorporated

Power Flame Incorporated Power Flame Incorporated SUGGESTED SPECIFICATION FOR MODEL NVC ULTRA LOW NOx GAS BURNERS SUB 9 PPM NOx THE POWER TO MANAGE ENERGY 2001 South 21st Street, Parsons, Kansas 67357 Telephone: 620-421-0480,

More information

HVAC Products. SAPHIR AirGo OEM Air Handling Unit Concept

HVAC Products. SAPHIR AirGo OEM Air Handling Unit Concept s HVAC Products OEM Air Handling Unit Concept Control solutions otal solution competence Application know-how and flexibility Access to future-oriented technologies State-of-the-art and open communication

More information