GROUP PANEL AHD 406H 406Hkat-englisch.doc
|
|
- Brook Skinner
- 5 years ago
- Views:
Transcription
1 GROUP PANEL AHD 0H 0Hkat-englisch.doc - microprocessor-controlled device for control desk installation - registers individual reports from, e.g., up to three KOMPAKT EDA--systems, via three serial inputs - forms 0 arbitrarily programmable groups; every individual report can activate up to two groups - internal print control - can print texts with characters each with printer AHD - serial outputs for addressing of cabin and mess-room panels - every group can be programmed as alarm or display - up to six sub-groups can be formed, that are available as relay contacts (floating transfer contacts) at the 0-pole terminal block - one horn and collective alarm relay each, sub-group relays - connection with ribbon cable and 0-pole terminal block - integrated engineer-calling system - available with individual LED or illuminated and automatically dimmed text-field for dark rooms - type approved by: Germanischer Lloyd Development, manufacturing, service for shipping and industry Böning Automationstechnologie GmbH & Co. KG Am Steenöver D- Ganderkesee Phone: +(0) -0 Fax: +(0) - Internet: info@boening.com
2 CONTENTS PAGE. General. Construction.0 Function. Data registration. Grouping. Alarms/displays. Acoustic acknowledgement.. Optic acknowledgement. Multiple addressing of a group. Lamp test. Collective alarm relays and subgroup relays. Engineer call.0 System failure. Dimming of the display elements Technical data Terminal diagram Dimensional drawing Order-related technical specification System-specific programming
3 . General AHD 0H is a group alarm and display unit for 0 groups and is mainly used on vessels (bridge). It has three serial inputs over which it can register individual reports per channel, which is reports altogether. Every report can address between zero and two groups. Every group can be programmed as alarm or display. Six subgroup relays with floating transfer contacts are available for control purposes. Each of these relays can be assigned (arbitrarily programmable) to the ten groups, as far as these are designated as alarms. The unit has two serial outputs to address the engineer- and messroom-control-panels. Additionally, it has a further serial output to control a printer.. Construction AHD 0H consists of two electronic cards which are connected by stay-rods. Together with the front panel, they form a plug-in unit. This plug-in unit is located in a housing for switchboard mounting according to DIN 00. It has front dimensions of mm x mm and an installation depth of mm. A 0-pole terminal block that can be mounted on TS or TS and a ribbon cable as plug-in connection between device and terminal block are part of the delivery. The front panel is available in the following two versions (see illustration on page of this description): - with individual LEDs and slide-in text field for illuminated rooms - with surface LEDs and text field as film-negative, e. g. for bridges on vessels.0 Function. Data registration AHD 0H registers the data over three serial inputs. As a source, among others, the following devices are possible: - alarm and monitoring system COMPACT EDA - data distributor AHD W - alarm and safety system AHD A The device receives the data according to the following serial protocol: Startbit (high), data bits out of which the high-bits can be grouped, control bits for serial acknowledgement, 0 to 00 bit stop (low). There are no start- or stop-bits during the transmission. The data rate is 00 baud. There are reasons for this unusual serial format which cannot be explained in detail here. However, it is possible to configure the software if necessary. Entering is done over optocouplers.. Grouping The device has an Eprom C or EEprom C, where the system-program and an area for the systemspecific programming are located. If a print-function is also required, an EPROM C is used, as in this case additional storage space for the texts is necessary. For grouping, further definition of the groups and sub-group relays, there are address fields on page of this description (system-specific programming). For access to the EPROM or EEPROM, the plug-in unit has to be torn out of the housing, after loosening the housing-frame and the fixing screw. The storage is located on the upper card and can be torn out of the IC-socket for programming.. Alarms/Displays Each group can be programmed as alarm or display. An alarm causes flashing of the corresponding measuring point. Simultaneously, the horn and collective alarm relay switch, and, as far as programmed,
4 Example for serial data registration 0hie.mcd Alarm- one of and the monitoring-systemcompact six sub-group relays, EDA too. A measuring point which is Group programmed panel AHD 0H as display shows steady light. Relays are not influenced by displays Failure Data Transmission Group 0 AHD 0H P OW ER DIM TES T AHD 0H INT ERNAL Ribbon cable Ribbon cable VDC±% SERIAL OU TPU T (FOR GROUPS) SERIAL OU TPU T SERIAL OU TPU T TEST HORN ACKN. LAMP TEST OPTICAL ACKN. SERIAL IN PUT SERIAL IN PUT SERIAL IN PUT HORN COLLEC T. REPORT VDC±% K K K K K K subgroup relays arbitrarily free programmable to the 0 groups displayed in the textfield. COLL. ALARM RELAY HORN RELAY SYSTEM FAILURE CALL ALL ENG SERIAL INPUT SERIAL INPUT SERIAL INPUT HORN ACKN. OPTIC. ACKN. SERIAL OUTPUT SERIAL OUTPUT PRINTER CONNECTION Start bit (high) data bits corresponding to meas. points to (high, if measuring point is active) Data rate is 00 Baud. Up to three COMPACT EDA can be connected to one group panel. control bits for serial acknowledgement 0 to 00 bit pause (low) Connection to further devices These inputs are usually not needed, as acknowledgement is done serially or over keys in the front panel.. Acoustic acknowledgement The horn relay can be reset with a key in the front panel or over a corresponding input at the terminal block. Furthermore, the horn relay can be acknowledged serially. If the group panel receives its data e. g. from the COMPACT EDA or from the data distributor AHD W, acknowledgement signals are transmitted serially from there, too.
5 . Visual acknowledgement A flashing measuring point changes to steady light by visual acknowledgement. This is also done with a key in the front panel or an input at the terminal block. Serial visual acknowledgement is also possible, which is done, e. g., by COMPACT EDA or the data distributor AHD W.. Repeated addressing of a group A group is usually a combination of several individual reports. In the event of an alarm, a group report that is already active but also acknowledged, is activated again, so that one individual report will not block the remaining alarms of the same group.. Lamp test The key for visual acknowledgement in the front panel of the device has also the function lamp test. All measuring points shine while it is pushed.. Collective alarm and subgroup relays Every alarm also causes switching of the collective alarm relay. In the event of a second alarm, the relay switches into normal position (closed) for app. s and then opens again (collective alarm repetition). A subgroup relay can be assigned to every measuring point, as far as it is programmed as alarm. If several measuring points have an effect on one relay, this relay can operate as first value indicator or, like the collective alarm relay, as new value indicator.. Call engineer If an alarm is not acknowledged acoustically in the engine control room within minutes (and thus serially the group panel, too), the relay CALL ALL ENG. switches. It is led to the 0-pole terminal block as normally-closed-contact and is reset after acknowledgement. In case chamber-/mess-room panels, within the scope of a st.-by alarm system, are connected to the device, this report will be activated there (serially), too..0 System failure AHD 0H has a relay that, under normal circumstances, has switched. The contact that leads to the terminal block is closed. In case of system failure or power failure the contact opens.. Dimming of display elements The construction of the device with a text field illuminated by surface LEDs, has a photo resistor by which the lucency of the LED is dimmed automatically depending on the ambient brightness. The maximal dimming at darkness can also be adjusted with a potentiometer in the front panel. Thus, dazzling or reflecting in the windowpanes is avoided.
6 AHD 0H 0H-e Ribbon cable VDC±% K K K K K subgroup relays arbitrarily programmable to the 0 groups displayed in the text field. K COLLECT. ALARM RELAY HORN RELAY SYSTEM FAILURE CALL ALL ENG SERIAL INPUT SERIAL INPUT SERIAL INPUT ENG-CALL ACKN. HORN ACKN. OPTIC. ACKN. CALL ALL ENG SERIAL OUTPUT SERIAL OUTPUT PRINTER CONNECTION Techncal data Power supply : VDC +/-% Power consumption of electronic : appr. 0.A Loadability of relay contacts : A, V Perm. ambient temperature : 0- C Perm. relative air humidity : % Degree of protection at front side : IP 0 (with front cap IP) Panel cutout : mm x mm Group - no. AHD 0H PO WER DIM 0 T EST 0-pole ribbon cable Short description Over serial inputs, the device can register up to individual reports from up to COMPACT EDA. Every individual report can be assigned aribtrarily to 0 to groups. The groups can be defined as alarms (flash, horn relay switches) or displays. Additionally, subgroups are available of which each can be assigned to any group displayed in the front panel. If an alarm group is not acknowledged for more than minutes, the relay CALL ALL ENG. switches. A storage area for the texts to be printed ( measuring points with characters each) is located in the EEprom (tear out insertion). Two serial outputs are available for addressing the chamber- and messroom-panels. 0 deep Terminal block is mountable on rails TS and TS
7 Order-related technical specification for group panel AHD 0H 0hm-e.mcd Group relay ( possible from K to K) Group as alarm (Al) or display (An) LED-Color (red, yellow or green) Group - no. Meas. point text GROUP RELAY DEFINITION K K K K K K First value indicator New value indicator Length of ribbon cable:... The assignment of the individual reports according to the here mentioned groups has to be defined in the measuring point lists. 0 Client Shipyard Newbuilding Com-no. (Böning) - Date:...
8 SYSTEM-SPECIFIC PROGRAMMING Serial input Serial input Serial input Individual report no. Eprom address st group Eprom address nd group Individual report no. Eprom address st group A0 A0 A0 AC0 AF0 A0 A A A AC AF A0 A A A AC AF A0 A A A AC AF A0 A A A AC AF A0 A A A AC AF A0 A A A AC AF A0 A A A AC AF A0 A A A AC AF 0 A0 A 0 A A 0 AC AF A0A AA AA AA ACA AFA A0B AB AB AB ACB AFB A0C AC AC AC ACC AFC A0D AD AD AD ACD AFD A0E AE AE AE ACE AFE A0F AF AF AF ACF AFF A0 A0 A0 AA0 AD0 B00 A A A AA AD B0 A A A AA AD B0 0 A A 0 A AA 0 AD B0 A A A AA AD B0 A A A AA AD B0 A A A AA AD B0 A A A AA AD B0 A A A AA AD B0 A A A AA AD B0 AA AA AA AAA ADA B0A AB AB AB AAB ADB B0B AC AC AC AAC ADC B0C 0 AD AD 0 AD AAD 0 ADD B0D AE AE AE AAE ADE B0E AF AF AF AAF ADF B0F A0 A0 A0 AB0 AE0 B0 A A A AB AE B A A A AB AE B A A A AB AE B A A A AB AE B A A A AB AE B A A A AB AE B 0 A A 0 A AB 0 AE B A A A AB AE B A A A AB AE B AA AA AA ABA AEA BA AB AB AB ABB AEB BB AC AC AC ABC AEC BC AD AD AD ABD AED BD AE AE AE ABE AEE BD AF AF AF ABF AEF BF The th individual report is set automatically in case of failure of the serial data and can thus be evaluated, too. Do not fill in addresses with content 00. Eprom address nd group Individual report no. Eprom address st group Eprom address nd group Program groups as alarm or display Group 0 Activation of the serial inputs Subgroup relay Group serial input 0 Eprom address Eprom address Eprom address Eprom address Assignment of the subgroup relays to the 0 groups (only alarms) Subgroup relay as first value or new value indicator BE BE BE BE BEA BEB BEC BED BEE BEF BE0 BE BE BE BE BE 0hp-e.mcd 00 = Alarm 0 = Display 00 = not active, 0 = active 00 = First value ind. Subgroup relays 0 = New value ind. (0 to 0 possible)
DEVELOPMENT MANUFACTURING SERVICE FOR SHIPPING AND INDUSTRY
DEVELOPMENT MANUFACTURING SERVICE FOR SHIPPING AND INDUSTRY 10A Impulse length dimmer AHD 601 for 24VDC, operation with photo resistor, potentiometer or pushbutton Alarm systems centralized and decentralized
More informationM1000 Alarm Annunciator
Data Sheet Alarm Annunciator Reliable Supervision and Control 10 inputs with LED indications Supports both NO/NC input contacts 10 open collector outputs Built-in siren relay Text label for alarm descriptions
More informationoverload programm mode stop
Engine temp.> 145 C Engine temp.> 155 C Engine temp. Sensor failure Engine overcurrent Engine current reg. Sensor failure 70% 85% 112 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59
More informationME 3011 compact. Electronic Alarm Indication Systems. Power Station Control Systems. Automation Equipment. Power Distribution Control Systems
Electronic Alarm Indication Systems ME 3011 compact Power Station Control Systems Power Distribution Control Systems Control Room Technology Automation Equipment 2 Table of Contents Contents Page System
More informationType 8001 PRIME MOVER CONTROLS INC. ALARM ANNUNCIATOR TYPE8001 FEATURES SB 8001B
PRODUCT BULLETIN SB 8001B Type 8001 ALARM ANNUNCIATOR TYPE8001 FEATURES 16 or 32 alarm points per flush mount enclosure Displays are backlit with long life LEDs and engraved to suit Dimmer controls built
More informationVideomatrix SIMATRIX 648
Videomatrix SIMATRIX 648 SIMATRIX 648 video matrix System characteristics Matrix unit Minimum configuration: 16/4 Maximum configuration: 64/8 Video inputs can be expanded in steps of 16, and video outputs
More informationModular Alarm, Monitoring and Control System
Modular Alarm, Monitoring and Control System Diesel Engine Monitoring and Ship Automation Expansions for Commercial Vessels Integrated Alarm, Monitoring and Control System Engines ü Monitoring every valuable
More informationSafety Instructions MS 10B ALARM UNIT MS 10B ALARM UNIT. Used symbols. Always observe this information to prevent damage to the device
Safety Instructions Used symbols Important Comments Before starting with installation of the MS 10B Alarm Unit, we recommend you to read the important information beneath. Qualification The installation
More informationPanel Mounted Fault Annunciator Series
Panel Mounted Fault Annunciator Series BSM / USM Panel-mounted fault annunciator Annunciators for panel mounting with,,,, 0 and signal inputs Storage of the last state of inputs and sequence in the case
More informationProduct overview. Issue date June 2009
Product overview Issue date June 2009 Page 2 Product overview Company Profile Fields of activity Böning Automationstechnologie GmbH & Co. KG specializes in the development and supply of devices and systems
More informationTRACENET TM TCM18 CONTROL AND MONITORING SYSTEM
TRACENET TM TCM18 CONTROL AND MONITORING SYSTEM APPLICATION OVERVIEW Control and monitoring systems play an essential role in heat tracing applications which range from freeze protecting water lines to
More informationTechnical Manual. Level Alarm Unit CARLA & WIDS
CARLA & WIDS Technical Manual SAS au Capital de 2 158 244-444 871 933 R.C.S. Bourges - APE : 2651B Headquarter : 9, rue Isaac Newton - 18000 Bourges - France Technical Manual CARLA for Tankers Cargo Tanks
More informationMSM - Expansion modules
MSM - Expansion modules Transistor- and relay modules for devices of the MSM-product family Free assignment of the output arrays to the input arrays of the annunciator Triggering of relays or transistor
More informationUniversal fault annunciator for panel mounting
Universal fault annunciator for panel mounting Communication over Ethernet USM - Universal-fault annunciator for panel mounting Low depth housing for panel mounting Versions with 8, 16, 32 or 48 inputs
More informationTRACENET TM TCM18 CONTROL AND MONITORING SYSTEM
TRACENET TM TCM18 CONTROL AND MONITORING SYSTEM APPLICATION OVERVIEW Control and monitoring systems play an essential role in heat tracing applications which range from freeze protecting water lines to
More informationPanel Mounted Fault Annunciator Series
Panel Mounted Fault Annunciator Series BSM / USM Panel-mounted fault annunciator Annunciators for panel mounting with 8, 16, 24, 32, 40 and 48 signal inputs Status retention of inputs and sequence in case
More informationANNUNCIATOR FIXED MODULE
12 Clintonville Road Northford, CT 06472 Phone: 203-484-7161 Fax: 203-484-7118 THE ANNUNCIATOR FIXED MODULE Installation Manual for the AFM-16ATF and AFM-32AF Annunciator Modules Document # 15970 3/27/95
More informationWindow facia fault annunciators
Window facia fault annunciators WAP Window Annunciator Panel 15.08.2017 Annunciators for panel mounting with 24 signal inputs Storage of the last state of inputs and sequence in the case of power failure
More informationProcess Alarm Solutions
Process Alarm Solutions Reliable Supervision and Control» Control. Monitor. Protect. SELCO Flexible alarm panels for supervision and control SELCO provides efficient and reliable solutions for alarm monitoring
More informationMAMI MULTI BASE STATION
MAMI MULTI BASE STATION INSTALLATION MANUAL SOFTWARE VER. S3C23 MAMI MANUFACTURING AND MINOR INVENTIONS TERRACE ROAD EDENVALE P.O. BOX 2699, EDENVALE, 6 TEL: +27 452 4737 FAX: +27 452 4738 { { { M.A.M.I.
More informationContents. Best Trusted and Rated Quality Products. PX-1 Stand-Alone Smoke Alarm. PX-1C Radiolink Smoke Alarm. PX-AR Alarm Relay
Product Line PX-I Stand-Alone Smoke Alarm PX- IC Radiolink Smoke Alarm PX-AR Alarm Relay PX-iP Wi-Fi Smoke Alarm System Pyrexx Web-App Colouresque Variety Accessories EN Contents 04 05 06 07 08 09 10 11
More informationParameterisable compact fault annunciator with permanent display
Parameterisable compact fault annunciator with permanent display FSM 10 Drop-flap fault annunciator 31.08.2010 Permanent display even on power failure Compact module for 10 alarms Supply and alarm signal
More informationProtecting you and your home
Gira smoke alarm device Dual Q Dual Q sounds the alarm when dangerous smoke formation is detected and fulfils the increased Q-Label quality requirements. Dual Q is a combined heat and smoke detector, thanks
More informationModular Alarm, Monitoring and Control System
Modular Alarm, Monitoring and Control System Diesel Engine Monitoring and Ship Automation Expansions for Yachts Modular Expansions for Yachts. Integrated Alarm, Monitoring and Control System Engines ü
More informationAnalog Annunciator Unit SACO 16 A3. Product Guide
Issued: Aprill 1999 Status: Updated Version: C/20.03.2006 Data subject to change without notice Features Powerful, flexible and field-customizable 16-channel analog input signal annunciator unit A full
More informationUSER MANUAL FOR OPERATING SYSTEM
P2262 ALARM PANEL USER MANUAL FOR OPERATING SYSTEM 21765-07 September 1999 Associated Controls (Aust) PTY. LTD. 29 Smith Street, Hillsdale, NSW, 2036. PH (02) 9311 3255, FAX (02) 9311 3779 Page 1 of 177
More informationStandard Devices. Electronic Alarm Indication Systems. ME 3011b
Standard Devices Electronic Alarm Indication Systems ME 3011b Before connecting and powering this device, please read carefully the manual, and refer to it whenever you have any doubts. This brochure is
More informationSystem examples Binary data remote transmission Binary alarm system Alarm system for analog meas. values On-duty/engineer call system Combined systems
SYSTEM EXAMPLES System examples Binary data remote transmission Binary alarm system Alarm system for analog meas. values On-duty/engineer call system Combined systems Binary data remote transmission 14
More informationSystem 9000TS Sequence of Events Recorder
System 000TS Sequence of Events Recorder ms Event Recorder and combined Annunciator Modular, rack mounting design expandable to over 000 inputs ms time stamping of events across the whole system Up to,000
More informationRTD TEMPERATURE SENSING SYSTEM
General Overview RTD TEMPERATURE SENSING SYSTEM The Prime Technology RTD Temperature System 9219-00-0002 is a three-channel temperature measuring system that utilizes two RTD Temperature Sensor inputs
More informationSeries 725 Programmable Alarm Annunciator
Series 725 Programmable Alarm Annunciar Multi-redundant design for greater reliability Modular construction from 1 256 alarm channels Multi-redundant design so there is no single point of failure Choice
More informationMonitoring and Control Technology. Superyacht Electronics. Refit Packages. Automat ions te chnol o gie.
Monitoring and Control Technology Superyacht Electronics Refit Packages Automat ions te chnol o gie www.boening.com 2 3 REFIT PACKAGES Superyacht Electronics Refit Packages Böning ship electronics are
More informationDRAFT 20 October 2014
Technical data MTL process alarm equipment EPS rev 8 Programmable alarm annunciator Modular construction from 1 to 256 alarm channels Multi-redundant design so there is no single point of failure Choice
More informationFC724 Fire control panel
FC724 Fire control panel Series FS720 (IP4) Cerberus PRO Compact, prefabricated microprocessor-controlled fire control panel for the connection of up to 504 addresses Fire control panel can be used as
More informationFC722 Fire control panel
FC722 Fire control panel Series FS720 (IP4) Cerberus PRO Compact, prefabricated microprocessor-controlled fire control panel for the connection of up to 252 addresses Fire control panel can be used as
More informationAnnunciator Unit SACO 16 D1. Product Guide
Issued: Aprill 1999 Status: Updated Version: C/20.03.2006 Data subject to change without notice Features Flexible, field-customizable 16-channel annunciator unit Alarm channels activated by normally open
More informationFC722 Fire control panel
FC722 Fire control panel Series FS720 (MPXS) Cerberus PRO Compact, prefabricated microprocessor-controlled fire control panel for the connection of up to 252 addresses Fire control panel can be used as
More informationSM3000 Videographic Recorder. User Guide. Modbus (RTU) Communications Option
SM3000 Videographic Recorder User Guide (RTU) Communications Option ABB The Company We are an established world force in the design and manufacture of instrumentation for industrial process control, flow
More informationGMA200-MT. Operation Manual. Gas detection controller for mounting rail assembly
Operation Manual GMA200-MT Gas detection controller for mounting rail assembly GfG GESELLSCHAFT FÜR GERÄTEBAU MBH KLÖNNESTRASSE 99 44143 DORTMUND, Germany TEL. +49 / (0)231 / 564 00 0 FAX +49 / (0)231
More informationItem Number Description Price. Accessories " Diesel/Water/Waste tank sender $ Battery temperature sensor $2.22
DIGITAL Vessel Monitoring 1800 Monitor Monitor includes head unit, surface mount bezel, surface mount gasket, DC current shunt 8255, AC current transformer 8256, battery temperature sensor 1820, connectors,
More informationME 3011C / Alarm Indication / Quick Reference Guide
Tables of Contents Page Application 1 Features 1 Important Safety Information! 2 Note to this Guide 2 Further Information 2 Device Variants 2 General Functions 3 Annunciator Sequences - ISA 18.1 3 Plan
More informationAnnunciator unit. Application
Issued: April 1999 Status: April 1999 Version: B/09.11.2001 Data subject to change without notice Features Flexible, field-customizable 16-channel annunciator unit Alarm channels activated by normally
More information2704 Controller Melt Pressure Controller
2704 Controller Melt Pressure Controller A. SUPPLEMENT 2704 MELT PRESSURE CONTROLLER. 2 A.. INTRODUCTION...2 A.2. WHAT IS THE MELT PRESSURE CONTROLLER?...2 a.3. INSTALLATION...3 a.4. WIRING CONNECTIONS...3
More informationModel A1700 Series Annunciator
Seekirk Model A1700 Series Annunciator Applications: For usage in all types of process industries, electric generation, transmission and distribution, gas and water utilities. Features: The Seekirk model
More informationProduct overview. Alarm indicator, operator and display panels
Product overview Alarm indicator, operator and display panels 1 2 Innovative operating concepts for safe power supply in all medical locations Despite all technology that is necessary in medical locations
More informationAIS750 Series Alarm Annunciator
Unparallel, modular, multipoint design with Integrated controllers Two Operation Modes (Stand-alone & Serial) All sizes confi gurable up to 440 Alarm Points RS485 / RS232 Serial Communication Manual &
More informationDifferential Pressure and Flow Meter Media 5 Indicator 160 PN 40
Differential Pressure and Flow Meter Media 5 Indicator 160 PN 40 Application Instrument designed to measure and indicate differential pressure or measured variables derived from it For gases or liquids
More informationTHE SOLUTION. MSM-Product family OPERATING MANUAL. A fault annunciator of the. BSM Basic fault annunciator for panel mounting. INFOwww.ees-online.
A fault annunciator of the MSM-Product family 17.07.2006 BSM Basic fault annunciator for panel mounting INFOwww.ees-online.de Contents overview 1 Validity 3 2 General notes 3 2.1 Used symbols 4 2.2 Used
More informationOn the job around the clock 24/7: Fire detection systems
On the job around the clock 24/7: Fire detection systems Version 02.2010 Version: 02.2010 Product catalogue Fire detection systems This product catalogue is intended for sales purposes only. For planning,
More informationESSEX ENGINEERING CORPORATION
WATER/WASTEWATER TREATMENT CONTROL SYSTEMS AND SUBSYSTEMS 2000 SERIES CONTROL SYSTEMS: 2000 series are for surface mounting inside a control cabinet Model 2024 Electronic Alternator Duplex (two pump) pump
More informationZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL
ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL PRODUCT Specification FEATURES Designed To Meet The Requirements Of EN54 Expandable From 1 To 5 Loops As Standard A Variety Of Networking Options
More informationTRACENET TM GENESIS CONTROL AND MONITORING SYSTEM SPECIFICATION GUIDE
TRACENET TM GENESIS CONTROL AND MONITORING SYSTEM SPECIFICATION GUIDE TRACENET TM GENESIS APPLICATION OVERVIEW Control and monitoring systems can play an essential role in heat tracing applications which
More informationFC724 Fire control panel
FC724 Fire control panel Series FS720 (IP5) Cerberus PRO Compact, prefabricated microprocessor-controlled fire control panel for the connection of up to 504 addresses Fire control panel can be used as
More information2604 Controller Melt Pressure Controller
2604 Controller Melt Pressure Controller A. SUPPLEMENT 2604 MELT PRESSURE CONTROLLER. 2 A.. INTRODUCTION...2 A.2. WHAT IS THE MELT PRESSURE CONTROLLER?...2 a.3. INSTALLATION...3 a.4. WIRING CONNECTIONS...3
More informationoperating device LOD , 144x72mm designed for retrofit
BNWAS le guardian 225 sm electrics operating device LOD 2.24.., 44x72mm designed for retrofit connecting module LCM 2.24.. over 5 installations easy and comfortable use simple connections to all peripheral
More informationDECKMA. GmbH. Decksmaschinen und Automation Vertriebs GmbH BEDIENUNGSANLEITUNG FÜR FEUERMELDEANLAGE USER MANUAL FOR FIRE ALARM SYSTEM
DECKMA GmbH Decksmaschinen und Automation Vertriebs GmbH BEDIENUNGSANLEITUNG FÜR FEUERMELDEANLAGE USER MANUAL FOR FIRE ALARM SYSTEM 815.5-2 815.5-6 VERSION 03/2003 Tel.: +49 (0)4105 / 65 60 0 * DECKMA
More informationReplaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge
Replaceable LED modules 11 Alarm Sequences as per ISA-18.1 standard Each channel/window fully field programmable RS232 or RS485 MODBUS-RTU communication Repeat relay for each window and multifunction relays
More informationBA AFMS3000 Operating instructions
20140208BA AFMS3000 Operating instructions DECKMA GMBH FIREALARMSYSTEM AFMS 3000 ALARM IN SEQU. MAINS DISCO NNECT PRE - ALARM FIRE TEST MODE A 1 2 3 FAULT A RESET 4 7 5 6 8 9 0 Version history Version
More information20 Light Remote Annunciator
Light Remote Annunciator Owner s Manual Surface Mount Flush Mount 94-95- Standard Annunciator 94-, 94-95-, 95-4- 4- Annunciator w/remote Relay Panel 4-, 4-4-, 4-49-, 49-49-, 49- Time Multiplexed Annunciator
More informationDipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Phone: Fax:
Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str. 5 35305 Grünberg Phone: 040 807-0 Fax: 040 807-259 Alarm indicator and test combination MK2430 Remote alarm indicator and test combination with LC display
More informationFC2020 Fire control panel
FC2020 Fire control panel Series FS20 (MP4.0) Sinteso Compact, prefabricated, microprocessor-controlled fire control panel for the connection of up to 252 addresses Fire control panel can be used as stand-alone
More informationAIS750 Series Alarm Annunciator User Manual (Ver. 2.3 / JUNE. 2014)
AIS750 Series Alarm Annunciator User Manual (Ver 23 / JUNE 2014) 3-350 John Street, Thornhill, tario L3T 5W6 Phone: 289 597 APEX (2739) Fax: 289 597 2200 Toll Free: 1 866 776 2943 Email: mail@annunciatorca
More informationFire control panel detect 3004 plus and accessories
Fire control panel detect 3004 and accessories The modular fire alarm panel detect 3004 is the basic version of a broad product portfolio of the system detect 3000. Up to 20 fire control panels can be
More informationSection PERIMETER SECURITY SYSTEMS
Section 28 16 43 PERIMETER SECURITY SYSTEMS PART 1 GENERAL 1.1 SUMMARY A. Provide and install a perimeter security system as herein specified for the purpose of detecting entry into a designated security
More informationTCM-2 Thyristor Control Module DATA SHEET
TCM-2 Thyristor Control Module TCM-2 Thyristor DATA DATA SHEET Control Module DATA SHEET Alarm panels Type Compact Q96 design Extremely easy push-button programming (no jumpers or the like) Individual
More informationCommunications None RS-232C RS-422* RS-485* BCD Transmission output*/** (4 to 20 ma) E5AX- E5AX- L(M)A02 L(M)A03
Digital Controller A 96 x 96-mm (DIN) Digital Process Controller Optimum PID control with feed-forward control circuitry. High accuracy (+0.3% FS +1 digit max.). Replaceable Output Units. Models with communications
More informationDENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION IBAS LIGHTING CONTROL
PART 0 A/E INSTRUCTIONS 0.01 DESIGN REQUIREMENTS A. Minimum lighting control (base scope of work) shall include all corridors. The lighting in all the corridors shall be turned on (if not already on) if
More informationASD 535 Aspirating smoke detector
ASD 535 Aspirating smoke detector From production number 3072 and FW version 0.06.00 The ASD 535 aspirating smoke detector performs the task of taking continuous air samples via one or two sampling pipe
More informationThe system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.
FireCell Radio Hub Fully addressable Wireless activation Third party approved (EN54) 2-way radio communication Loop powered Diagnostics port Range in excess of 150 metres Overview The model FCX-500-001
More informationINPUT / OUTPUT MINI MODULES
INPUT / OUTPUT MINI MODULES APPLICATION The Addressable Control and Monitor mini modules are the latest technology for a loop powered module. Installed on the same loop with other devices such as detectors
More informationApplication, Installation, Operation & Maintenance Manual
APPROVED BY:JBJ PRESCIENT III FIRE ALARM & GAS EXTINGUISHING CONTROL PANEL Application, Installation, Operation & Maintenance Manual PAGE 1 of 43 CONTENTS 1. INTRODUCTION... 3 2. GENERAL DESCRIPTION...
More informationFire Control Panel FS4000
Fire Control Panel FS4000 INSTRUCTION MANUAL Revision 4/02.11 Contents 1. Introduction... 4 2. Terminology... 4 3. Function... 5 4. Technical features... 5 4.1 Fire alarm lines... 5 4.2. Current thresholds
More informationIntesisBox BACnet/IP Server - Notifier ID3000 series
IntesisBox Server - Notifier ID3000 series Gateway for integration of Notifier ID3000, ID3002, ID50 and ID60 fire panels into enabled control systems. Integrate your Notifier fire panels into your BACnet
More informationPHOTOELECTRIC AMPLIFIER SERIES
PHOTOELECTRIC AMPLIFIER SERIES Telco s photoelectric amplifier series performs as good today as it did when it first appeared almost 25 years ago. But while the simple design of this iconic product has
More informationACCURATE ELECTRONICS INC
ACCURATE ELECTRONICS INC Page 1 of 7 Model 108078 2 Sept 09 WWW.ACCURATE.ORG PO BOX 1654 97075-1654 8687 SW Hall Blvd 97008 BEAVERTON OR USA 503.641.0118 FAX 503.646.3903 Practice Section 108078 Rev A
More informationFlair 500 Series Annunciators
Flair 500 Series s Basics Flair Multi-Zone s (MZAs) are fully functional, flexible, programmable micro controller based alarm control panels. They can be used independently d or in conjunction with other
More informationINSTRUCTION MANUAL. DECKMA HAMBURG GmbH. Type OMD-12. Oil-in-Water Monitor
INSTRUCTION MANUAL Oil-in-Water Monitor Type OMD-12 DECKMA HAMBURG GmbH Kieler Straße 316, D-22525 Hamburg Tel.: ++49 40 54 88 76-0, Fax: ++49 40 54 88 76-10, email: post@deckma.com IMPORTANT NOTICE Replacement
More informationModel A2100 Series Annunciator
Seekirk Model A2100 Series Annunciator Applications: For usage within transformers, switchgear, breakers and/or within any processing equipment or control room applications either attended or unattended
More informationFire control panels FC726 FC726-XA
Fire control panels FC726 FC726-XA Modular, pre-confectioned, microprocessor-controlled fire control panel for up to max. 1512 device addresses Integrated, user-friendly operating unit Detection and automatic
More informationDIESEL ENGINE CONTROL UNIT DCU USER S MANUAL - N-2000 Lillestrøm, Norway Tel: (+47) Fax: (+47)
DIESEL ENGINE CONTROL UNIT DCU 205 - USER S MANUAL - N-2000 Lillestrøm, Norway Tel: (+47) 64 84 52 00 Fax: (+47) 64 84 52 12 office@auto-maskin.no - 1 - TABLE OF CONTENTS 1. INTRODUCTION TO THE DCU 205...4
More informationEnvironmentalMonitoring
Datasheet Numerous sensors, detectors and expansion modules are available for the requirements in ambient and device monitoring. All units are self-developed by Neol so the highest technical requirements
More informationDevices for Special Applications
Overview AP 2/11 UP 2/12 N 26/02 UP 28/11 UP 28/21 N 342 AP24/02 GE 22 GE 23 GE 24 UP 2 AP 2 Control Integrated constant light level control 1-channel 3-channel -- -- -- 1-channel -- -- 1-channel -- 1-channel
More informationFDMM01S - FDMM02 - FDMM10- FDMM11S FDMM12 - Input / output mini modules
Application The Addressable Control and Monitor mini modules are the latest technology for a loop powered module. Installed on the same loop with other devices such as detectors and manual call points,
More informationFC723 Fire control panel
FC723 Fire control panel FS720 series (IP5) Cerberus PRO Modular, prefabricated, microprocessor-controlled fire control panel with integrated user-friendly operating unit for up to max. 756 addresses Processes
More informationSERVICE INSTRUCTIONS FOR. Fire Alarm System MINI-2000
SERVICE INSTRUCTIONS FOR Fire Alarm System MINI-2000 Version 1.3 02.04.1998 Jari Ollila Tom Brunberg Oy Esmi Ab Copyright Oy ESMI Ab, 1991... 1998 The copyright to the documentation herein is the property
More informationEA-MINI / EA-MINI-V. LEITRONIC AG Swiss Security Systems
4923 Table of contents Overview... 2 2 Applications... 3 2. Door-phone... 3 2.. Wiring... 3 2.2 Alarm dialler... 4 2.2. Wiring... 4 3 Mechanical fitting... 5 3. Retrofit solutions to existing elevators...
More informationSPEF 3A2 C. Fault indicator. User s manual and Technical description SPEF 3A2 C. f n SPA. Serial port. RS AA Ser.No.
SPEF 3A2 C Fault indicator User s manual and Technical description SPA f n = 50Hz x 60Hz U aux =24V- REGISTERS 0 1 I L1 [ A] 2 I L2 [ A] 3 I L3 [ A] 4 t ( I > )[%] 5 I o [ A] 6 t ( I o > )[%] 7 I [%] 8
More informationAddressable Fire Alarm Control Panel
PRODUCT SPECIFICATION XR2400F Addressable FACP Addressable Fire Alarm Control Panel Description The DMP XR2400F Addressable Fire Alarm Control Panel is an expandable Fire Alarm Control with built-in DACT
More informationFire control panels FC360
Cerberus TM FIT Fire control panels FC360 FC361-ZZ, FC361-ZA, FC361-YZ, FC361-YA Fire control panels (1-loop) for addressable peripheral devices with integrated operating unit One loop with 126 addresses
More informationGas Controller Module GC-06
Page 1 Oct. 2015/2 Measuring, warning and controlling module for toxic, combustible and refrigerant gases and vapours. The gas controller series GC-06 is designed in accordance with the standard EN 50545-1.
More informationSolution F2. Fire Alarm Control Panels one step ahead.
Solution F2 Fire Alarm Control Panels one step ahead. Sicherheitstechnik Sicherheitstechnik GmbH GmbH The Fire Alarm Control Panel Solution F2 Solution F2 in B2 enclosure (B01090-00) The Concept The Solution
More informationM2000 Engine Controller
M2000 Engine Controller Integrated control and protection of diesel and gas engines for all purposes Especially suited for auxiliary generator sets 1 IN OPERATION 1 2 STARTFAIL 2 3 OVERSPEED RPM FAIL 3
More informationAdvance Optima Module Magnos 17
Advance Optima Module Magnos 17 Service Manual 43/24-1002-0 EN Table of Contents Page Chapter 1: Description of functions 1-1 Chapter 2: Module variants and components 2-1 Chapter 3: Analyzer variants
More informationRemote alarm indicator and test combination MK2430
Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str. 5 35305 Grünberg Tel.: 040 807-0 Fax: 040 807-259 Remote alarm indicator and test combination MK2430 Remote alarm indicator and test combination with LC
More informationInfo-Display xx
The Info-Display receives telegrams via the instabus EIB and allows the representation (LC display) of freelyprogrammable texts and values. Up to 12 pages with 1, 2 or 4 lines are programmable. A function
More informationInstallation & Operating Instructions
FH-RT Wireless Room Thermostat FH-BU Wireless Base Unit Installation & Operating Instructions Specification Base unit (230 V) Order Code: Primary voltage: Secondary voltage: Outputs 1-6: Outputs 7-8: 088H011901
More informationTrueAlert Addressable Notification Appliances
Fire Control ** IS NORMAL ** :0:pm Mon 9-Feb-9 SY S TE M AC SUPERVISORY TROUB LE SILENCED SUPV TROUBLE SILENCE RESET CONTROL DISC ON NEC T POW ER + V ZONE P WR + 0V ZONE P WR - +IDNE T IDC + - IDNE T IDC
More informationISOSCAN EDS460-DG. Insulation fault locator for DC IT systems with high system leakage capacitances
ISOSCAN Insulation fault locator for DC IT systems with high system leakage capacitances _D00108_00_D_XXEN/05.2015 ISOSCAN Insulation fault locator for DC IT systems with high system leakage capacitances
More informationCAN bus-based I/O module, CIO relays Mounting Terminals and wiring Commissioning, using the utility software
INSTALLATION AND COMMISSIONING GUIDE CAN bus-based I/O module, CIO 208 8 relays Mounting Terminals and wiring Commissioning, using the utility software DEIF A/S Frisenborgvej 33 DK-7800 Skive Tel.: +45
More informationConstant climate chambers
Constant climate chambers KBF 115 (E2) - Constant climate chamber The KBF series was particularly designed for absolutely reliable stability tests and precise maintenance of constant climatic conditions.
More information