Fire System Components

Size: px
Start display at page:

Download "Fire System Components"

Transcription

1 4.1 Fire System Components CSA-CAT-11 Cooper CSA srl Toll Free Number

2 Pictorial Index Power supply units Sign boards Switching power supply unit 27,6 Vdc Series B page 6 Aluminium sign boards Series 1500 page 16 Switching power supply unit 27,6 Vdc Series page 7 Sign boards in thermoplastic material Series 5000 page 17 Electromagnetic door release units Sign boards IP 65 Series 5500 page 18 Electromagnetic door release unit in plastic case - Series page 8 Sign boards IP 54 compliant with EN54-3 Series 5900 page 19 Electromagnetic door release unit in metal case - Series page 9 Manual call points Compact electromagnetic door release unit - Series 1330 / 1340 page 10 Call point EN54-11 Series CXM page 22 Aluminium electromagnetic door release unit - Series 1350 / 1360 page 11 Glass break call point Series 2495 pag 23 Flush-mounting electromagnetic door release unit 1368 page 12 Bells Floor-mounting electromagnetic door release unit 1369 page 13 Classic bell Series GONG page 24 Electromagnetic door release unit with bracket - Series 1370 / 1380 page 14 Electronic bell IP 55 Series F-Bell page 25

3 Pictorial Index Sounders Combined sounders and beacons Electronic sounder Series ROLP page 26 Ceiling-mounting electronic sounder Series SQUASHNI MICRO page 27 Horn electronic sounder Series SYMPHONI HO page 28 Combined sounder and beacon FS24 page 30 Combined outdoor sounder and beacon Series FLASHNI page 31 Beacons Optical and electro-acoustic repeaters Optical-acoustic repeater Series 1420 page 36 Compact optical-acoustic repeater Series 1490 page 37 Optical-acoustic repeater Series 1491 page 38 Key boxes and disconnecting switches Glass break key box 1492 / 1493 page 39 Key box 1498 page 40 Metallic base beacon 1478 / 1481 page 32 Key disconnecting switch 2490 page 41 Light indicator Series 1483 / 1486 page 33 Prism light indicator 1489 page 34 High efficiency beacon Series SOLEX page 35 Ex article Explosion proof metallic call point Series 1460 page 42 PX / PX PX / PX page 43

4 Company presentation page 4 Power supply units Series B Switching power supply unit 27,6 Vcc page 6 Series Switching power supply unit 27,6 Vcc page 7 Electromagnetic door release units Series Electromagnetic door release unit in plastic case page 8 Series Electromagnetic door release unit in metallic case page 9 Series 1330 / 1340 Compact electromagnetic door release unit page 10 Series 1350 / 1360 Aluminium electromagnetic door release unit page Flush-mounting electromagnetic door release unit page Floor-mounting electromagnetic door release unit page 13 Series 1370 / 1380 Electromagnetic door release unit with bracket page 14 Accessorieses for electromagnetic door release units page 15 Sign boards Series 1500 Aluminium sign boards page 16 Series 5000 Thermoplastic sign boards page 17 Series 5500 Sign boards IP 65 page 18 Series 5900 Sign boards IP 54 compliant with EN54-3 page 19 Contents Writings available for sign boards page 20 Accessorieses for sign boards page 21 Call points Series CXM Call point EN54-1 page 22 Series 2495 Glass break call point page 23 Bells Series GONG Classic bell page 24 Series F-Bell Electronic bell IP 55 page 25 Sounders Series ROLP Electronic sounder page 26 Series SQUASHNI MICRO Ceiling-mounting electronic page 27 Series SYMPHONI HO Horn electronic sounder page 28 Sounder tones table page 29 Combined sounders and beacon FS24 Combined sounder and beacon page 30 Series FLASHNI Combined outdoor sounder and beacon page 31 Beacons 1478 / 1481 Metallic base beacon page 32 Series 1483 / 1486 Light indicator page Prism light indicator page 34 Series SOLEX High efficiency beacon page 35 Optical and optical-acoustic repeaters Series 1420 Optical-acoustic repeater page 36 Series 1490 Compact optical-acoustic repeater page 37 Series 1491 Optical-acoustic repeater page 38 Key boxes and disconnecting switches 1492 / Glass break key box page Key box page Key disconnecting switch page 41 Ex articles Series 1460 Explosion proof metallic call point page 42 PX / PX / PX / PX page 43 Technical specifications page 44 General terms of business page 49 The manufacturer reserves the right of modifying the data contained in this catalogue without notice.

5 Index by code CODE Page CODE Page CODE Page Page BSP CSA SP D D D CSA D CSA CSA CSA CSA CSA CSA CSA CSA CSA CSA CSA D D D D 14 13ST ST BZ BZ BZ-I CSA A CSA FR-IN VR VR CSA CSA CSA CT CSA CSA CSA CSA CSA CSA VR S S S S S S BZ CSA U CSA CSA V FUL-0048XC FUL FUL FULL-0122X FULL-0174X FULL FULL FULL LOGO LOGO FULL FULL FULL FULL FULL FULL FULL FULL FULL FULL-0389X FULL-0403X FULL-0110X FULL-0111X FULL FULL FULL FULL CSA FUL FUL FULL-0246X FULL-0238X FULL FULL-0009X BG BP CSA BG CSA BG CSA 7 CSA CSA CSA CSA CSA CSA CSA CSA CSA CSA CSA CSA CSA08660W 20 CSA CSA CSA08662W 20 CSA CSA CSA08664W 20 CSA CSA CSA CSA08667W 20 CSA CSA08668W 20 CSA CSA0866A 20 CSA CSA CSA08671W 20 CSA CSA08672W 20 CSA CSA CSA CSA CSA CSA08677W 20 CSA CSA CSA08679W 20 CSA CSA08682W 20 CSA CSA08683W 20 CSA CSA08684W 20 CSA CSA CSA08689A 20 CSA08689AW 20 CSA08689B 20 CSA08689BW 20 CSA08689W 20 CSA08691W 20 O-1490-BZG 37 O-1490-BZR 37 O-1490-BZV 37 O-1490-CG 37 O-1490-CR 37 O-1490-CV 37 O-1490-G 37 O-1490-R 37 O-1490-V 37 O-1553-CSA 16 O-1554-CSA 16 O-1555-CSA 16 O O V 17 O-5050-CSA 17 O O V 17 O-5051-CSA 17 O-5052-CSA 17 O-5053-CSA 17 O-5054-CSA 17 O-5055-CSA 17 O O-5055-CSA 18 O-5553-CSA 18 O-5554-CSA 18 O-5555-CSA 18 O-FS24 30 PX PX PX PX W

6 The group Cooper Industries Founded as a small foundry in 1833 at Mount Vernon in Ohio, USA, by the brothers Charles and Elias Cooper, Cooper Industries is now a worldwide manufacturer with leadership positions in the electrical market. In the first 125 years of its history, the company was concentrated in the production of gas compression and distribution devices, as well as diesel engines for boats. In 1960 Cooper started a products portfolio diversification process with a series of takeovers and a slight international expansion. Today the product lines include equipment for the oil industry, products for electric power distribution, emergency lighting, fire and intrusion systems. The presence of Cooper in Europe must be attributed to a series of takeovers of high level brands such as CEAG, Menvier, and MTL. With a vast network of companies, Cooper Industries holds today a strong leadership in innovation, development, production, distribution and technical support in the whole world. 4 Fire System Components Toll Free Number

7 Cooper Safety When there are lives and properties to protect, there is no room for compromises, and you need a partner that can support you with tested and certified products, with capacity and international expertise and the local support as well. Here is where Cooper Safety comes into the picture. As a division of the Cooper Industries group, we are a global leader in solutions and technologies designed to save lives and protect the properties. Our products and brands, leader on the market, are present in the most demanding industrial, residential and commercial environments, where we are able to offer solutions for fire detection, intrusion, emergency lighting and escape route indication, traditional and LED lighting, emergency notifications. Cooper CSA It is a company of the Cooper Industries group, active on the Italian market since more than 35 years with products and solutions for the fire and intrusion security and the emergency lighting. Cooper CSA is based in Corsico, Milano where it operates with a team of highly specialized promoters and commercial officers and a network of branches diffusely spread over the national territory. Every day in contact with designers, dealers and engineers, our staff is able to provide support in all phases of the project, from the development of complex technological systems to their commissioning, with a precise and prompt service. We provide safety to persons and goods with passion and competence With a enviable reputation as for innovation, quality and performance, our range of products includes brands such as CEAG systems for emergency lighting, Menvier equipment for emergency lighting, CSA - Fulleon - Wheelock components and Accessorieses for fire and security systems, MEDC signalling devices for dangerous areas, Scantronic wired and wireless intrusion systems. The continuous international success is the result of passion and ability of our business units that offer an excellence and innovation heritage in their respective fields of competence. Fire System Components Toll Free Number

8 Power supply units Switching power supply unit 27,6 Vcc Series B Switching technology High efficiency Small & large versions of metallic casing available Pb Battery Charging Available output current: 1,5 A, 2,5 A, 5A CPD Certified UNI EN 54:1997+A1:2002+A2: Switching power supply unit with 27,6 Vcc output, available with a maximum output current of 1,5, 2,5 and 5A. High effi ciency and minimum heat losses heat dissipation, thanks to switching technology. The unit is protected from overloads, polarity reversals inversions and short circuits. 4 LEDs indicate power supply status: mains power (green), battery charging (green), battery discharged (yellow) & fault (yellow). Specifi cally recommended as an auxiliary power supply unit for fi re detection system components such as electromagnets, notifi cation devices, etc. Using the unit in large systems eliminates the problem of long power cable runs which simplifi es installation. The case comes provided with a mechanic lock for opening and closing the front door. Power Supply Units series 82000B are CPD certifi ed in accordance with the standard UNI EN54-4: A1: A2:2006 Housing material Epoxy varnished sheet Connection type Terminals Power supply 230 Vca %, Hz Input mains, output battery, output load, open collector Lines output for remote indications, general alarm outputs through clean relay contacts. Door opening detection. Fuses for mains and battery overload, Electrical protection Short circuit in output, battery inversion. Door opening tamper. Operating Temperature +5 C +40 C Insulation Class Classe I IP Degree IP 30 Standard equipment Two keys per lock BOX A BOX B A B C power Output current Output Type and number of compatible batteries Package weight Notes 82415BP 42 W 1,5 A 27,6 Vcc 2 x 12V 3A Pb Gel 4,1 Kg Case type A (batteries not provided) 82415BG 42 W 1,5 A 27,6 Vcc 2 x 12V 3A Pb Gel 6,2 Kg Case type B (batteries not provided) 82425BG 70 W 2,5 A 27,6 Vcc 2 x 12V 7A Pb Gel 6,5 Kg Case type B (batteries not provided) 82450BG 140 W 5 A 27,6 Vcc 2 x 12V 17A Pb Gel 6,7 Kg Case type B (batteries not provided) Power supply unit with door open. N.B. Battery not provided 6 Fire System Components Toll Free Number

9 Power supply units Switching power supply unit 27,6 Vcc Series Switching technology Reduced size High efficiency Recharge for Pb batteries Available output current: 1,5 A, 2,5 A, 5A Certificate IMQ-CSV UNI EN :2001 Switching power supply unit with 27,6 Vcc output, available with a maximum output current of 1,5, 2,5 e 5A. High effi ciency and minimum heat losses, thanks to the switching technology. The unit is protected from overloads, polarity reversals and short circuits. The mains presence is indicated by a green coloured LED. Specifi cally recommended in systems that require small to medium size power supply units to be installed in false ceilings or case suited to accommodate concentrators or junction boxes. In fi re security systems it is useful for the supply of panels, electromagnets, sounders and bells. Using the unit in large systems eliminates the problems with long power cable runs and simplifi es the construction of the system. Power supply units of the series are CSV IMQ certifi ed according to UNI EN CSA CSA CSA A B C Housing material Connection type Power supply Lines Electrical protection Operating Temperature Isolation Class Galvanized steel sheet Terminals 230 Vca %, Hz Mains input, battery output, load output Fuses for mains, overload, over in output, short circuit in output +5 C +40 C Class I power Output current Output CSA 42 W 1,5 A 27,6 Vcc CSA 70 W 2,5 A 27,6 Vcc CSA 140 W 5 A 27,6 Vcc Type and number of compatible batteries 2 x 12V 3A Pb Gel 2 x 12V 7A Pb Gel 2 x 12V 17A Pb Gel Package weight Notes Notes CSV IMQ 0,4 Kg Model A CSV IMQ 0,6 Kg Model B CSV IMQ 0,8 Kg Model C Fire System Components Toll Free Number

10 Electromagnetic door release units Electromagnetic door release unit in plastic case Series Wall and floor mounting (with accessory) Modern design Holding strength 50 Kg Low current consumption Release button and protection circuit Completed with damping keeper plate CPD certificate UNI EN1155: Electromagnetic door release unit in plastic case for fi re doors equipped with a large red unlocking button that can be easily located. The door release units of the series are equipped with a built-in spring releaser that allows overcoming residual magnetic forces therefore ensuring a quick and reliable release of the door. The circuit includes a dual protection diode against disturbances and polarity reversals. Three lateral inputs are available for the connection of 16 or 20 mm hoses and one back input for cables with a maximum diameter of 10 mm. A version is available with the door status control that indicates, with the electromagnet energised, if the door is open (NC type) or closed. Provided with counter-plate. With a suitable bracket, upon request, fl oor mounting is possible. CPD certifi cation according to UNI UNI EN1155:2003. General specifi cations Housing material Core material Keeper plate material Operation Connection type Operating Temperature Standard equipment Thermoplastic black or white Steel Support in thermoplastic, steel plate Released when de-energised Terminals -10 C +55 C Flexible keeper plate, release button, diodes protection circuit Holding strength ±15% current Door status Colour Package weight CSA 50 Kg/490 N 24 Vcc 45 ma no nero 0,56 Kg N 2 protection diodes SP 50 Kg/490 N 24 Vcc 45 ma si nero 0,56 Kg N 2 protection diodes BSP 50 Kg/490 N 24 Vcc 45 ma si bianco 0,56 Kg N 2 protection diodes Notes Accessories (see in page 15) 1353-CSA 55 mm diameter fl exible keeper plate 13ST15 Floor/wall mounting 150 mm bracket 13ST25 Floor/wall mounting 250 mm bracket 8 Fire System Components Toll Free Number

11 Electromagnetic door release units Electromagnetic door release unit in metal case Series es Wall and floor mounting (with accessory) Holding strength 20 Kg and 50 Kg Release button Integrated fairleads Completed with damping keeper plate Permanent version UNI EN1155: Electromagnetic door release unit in metal case for fi re doors equipped with an easily located unlocking button. The classic design construction gives the product a high robustness. A built-in spring releaser allows overcoming residual magnetic forces therefore ensuring a quick and reliable release of the door. Two fairleads for connecting up to 16mm hoses and one back hole with a diameter of 18mm are available. Provided with counter-plate. With a suitable bracket, upon request, fl oor mounting is possible. CPD certifi cation according to UNI EN1155:2003. Models supplied with 20kg with press hose M20 Models from 50kg supplied with cable hole diameter 20 General specifi cations Housing material Steel, epoxy white painting Core material Steel Keeper plate material Black ABS support, steel plate Operation Released when de-energised Connection type Terminals Operating Temperature -10 C +55 C Protection grade IP 42 Standard equipment Flexible keeper plate, code 1341-CSA, Release button, protection diode Core diameter 50 for models from 50kg Holding Strength ± 15% current Package weight D 20 Kg/200 N 24 Vcc 25 ma 0,56 Kg N 1 protection diode D 50 Kg/490 N 24 Vcc 45 ma 0,73 Kg N 1 protection diode Notes Accessorieses (see in page 15) 1343-CSA 55 mm diameter fl exible keeper plate 13ST15 Floor/wall mounting 150 mm bracket 13ST25 Floor/wall mounting 250 mm bracket Fire System Components Toll Free Number

12 Electromagnetic door release units Compact electromagnetic door release unit Series 1330/1340 Wall mounting Holding strength 50 and 100 Kg Versions with release button available Complete with damping keeper plate CPD certified UNI EN1155: Electromagnetic door release unit for fi re doors. The simple and compact construction enables a reduced size and a very interesting quality/cost ratio. The door release units series 1330/1340 are equipped with a built-in spring releaser which ensures that residual magnetic forces are overcome therefore guaranteeing a quick and reliable release of the door. Supplied with a dual protection diode for protection against disturbances and polarity reversals. Counter-plate included as standard. CPD certifi ed in accordance with UNI EN1155:2003. Base material magnet Thermoplastic black Core material Steel Keeper plate material Thermoplastic black support, steel plate Operation Released when de-energised Operating Temperature -10 C +55 C Protection degree IP 40 Standard equipment Flexible keeper plate, circuit protection diodes Holding strength ±15% Operating current Core diameter A Height B Unlocking button Connection type Package weight 1330-D 50 Kg/490 N 24 Vcc 45 ma 50 mm 36 mm no Wired 0,54 Kg N 2 protection diodes 1335-CSA 50 Kg/490 N 24 Vcc 45 ma 50 mm 36 mm si Terminals 0,55 Kg N 2 protection diodes 1340-D 100 Kg/980 N 24 Vcc 100 ma 60 mm 40,5 mm no Wired 0,80 Kg N 2 protection diodes 1345-CSA 100 Kg/980 N 24 Vcc 100 ma 60 mm 40,5 mm si Terminals 0,81 Kg N 2 protection diodes 1335-CSA 1345-CSA Notes Accessorieses (see on page 15) 1353-CSA 55 mm diameter fl exible keeper plate 1363-CSA 60 mm diameter flexible keeper plate 10 Fire System Components Toll Free Number

13 Electromagnetic door release units Aluminium electromagnetic door release unit Series 1350/1360 Wall mounting User selectable dual holding strength Aluminium case Release button and protection circuit Complete with damping keeper plate CPD certificate UNI EN1155: Aluminium electromagnetic door release unit for fi re doors equipped with an unlocking button that can be positioned on both sides. The aluminium case with epoxy varnishing ensures a high robustness. The circuit includes a dual protection diode against disturbances and polarity reversals. The holding strength can be selected by means of a specifi c internal link (25/50 Kg and 50/100 Kg). A built-in spring releaser allows overcoming residual magnetic forces therefore ensuring a quick and reliable release of the door. Provided with counter-plate. CPD certifi cation according to UNI EN1155:2003. Housing material Cover material Core material Keeper plate material Operation Connection type Operating Temperature Die cast aluminium with white epoxy varnishing Thermoplastic black Steel Thermoplastic support, steel plate Released when de-energised Terminals Protection degree IP 40 Standard equipment -10 C +55 C Flexible keeper plate, release button, diodes protection circuit Holding strength ±15% Operating current Core diameter A Height B Package weight 1350-CSA Kg/ N 24 Vcc ma 50 mm 45 mm 0,8 Kg N 2 protection diodes 1360-CSA Kg/ N 24 Vcc ma 60 mm 50 mm 1 Kg N 2 protection diodes Notes Accessorieses (see on page 15) 1353-CSA 55 mm diameter fl exible keeper plate 1363-CSA 60 mm diameter flexible keeper plate Fire System Components Toll Free Number

14 Electromagnetic door release units Flush mounting electromagnetic door release unit 1368 Flush mounting Holding strength 50 Kg Complete with damping keeper plate CPD certificate UNI EN1155: Flush mounting electromagnetic door release unit for fi re doors. It is composed of an electromagnetic core fi tted inside a steel metallic box with an anodised aluminium front panel. A built-in spring releaser allows overcoming residual magnetic forces therefore ensuring a quick and reliable release of the door. Provided with dual protection diode against disturbances and polarity reversals. Provided with counter-plate. CPD certifi cation according to UNI EN1155:2003. Housing material Materiale frontale Core material Galvanized steel Anodised Alluminium Steel Keeper plate material Black thermoplastic support, nickelate steel plate Operation Released when de-energised Connection type Wired Operating Temperature -10 C +55 C Protection degree IP 40 Standard equipment flexible keeper plate, protection diodes 2 pc. / package Holding strength ±15% current Package weight 1368-CSA 50 Kg/490 N 24 Vcc 45 ma 1,30 Kg N 2 protection diodes Notes Accessorieses (see page 15) 1353-CSA 55 mm diameter fl exible keeper plate 12 Fire System Components Toll Free Number

15 Electromagnetic door release units Flush mounting electromagnetic door release unit 1369 Flush mounting Aluminium case Holding strength 50 Kg Release button Complete with damping keeper plate CPD certificate UNI EN1155: Electromagnetic door release unit for fi re doors designed for fl oor mounting. The aluminium case with epoxy varnishing ensures a high robustness. Provided with dual protection diode against disturbances and polarity reversals. A built-in spring releaser allows overcoming residual magnetic forces therefore ensuring a quick and reliable release of the door. Provided with counter-plate. CPD certifi cation according to UNI EN1155: Housing material Core material Keeper plate material Operation Connection type Operating Temperature Aluminium with black epoxy varnishing Steel Black thermoplastic support, steel plate Released when de-energised Wired Protection degree IP 40 Standard equipment -10 C +55 C Flexible keeper plate. Release button. Protection diodes Ø Holding strength ±15% current Package weight 1369-CSA 50 Kg/490 N 24 Vcc 45 ma 0,95 Kg N 2 protection diodes Notes Accessorieses (see page 15) 1353-CSA 55 mm diameter fl exible keeper plate Fire System Components Toll Free Number

16 Electromagnetic door release units Electromagnetic door release unit with bracket Series1370/1380 Floor, wall or ceiling mounting Holding strengths 50 and 100 Kg Release button Complete with damping keeper plate Adjustable mounting height within 30 mm CPD certificate UNI EN1155: Aluminium electromagnetic door release unit for fi re doors equipped with an unlocking button. Thanks to two different core mounting positions, axial and perpendicular, and to the adjustable head within 30mm, both wall and fl oor mounting is possible. The aluminium case with epoxy varnishing ensures a high robustness. The suitable cover of the base conceals the fi xing screws, providing an optimum aesthetic result. Provided with dual protection diode against disturbances and polarity reversals. A built-in spring releaser allows overcoming residual magnetic forces therefore ensuring a quick and reliable release of the door. The strong metallic structure and its versatility in installation make this door release unit an ideal solution for hospitals, hotels, shopping centers, and industrial hangars. Provided with counter-plate. CPD certifi cation according to UNI EN1155:2003. Core support material Core material Bracket material Base cover material Keeper plate material Operation Connection type Operating Temperature Aluminium with black epoxy varnishing Steel Aluminium with black epoxy varnishing Black thermoplastic Black thermoplastic support, steel plate Released when de-energised Wired Protection degree IP 40 Standard equipment -10 C +55 C Flexible keeper plate. Release button, base cover, protection diodes Holding strength ±15% current Core diameter A Height B Height C Height D Counter-plate provided Package weight Notes D 50 Kg/490 N 24 Vcc 45 ma 50 mm 28 mm mm mm Cod ,2 Kg N 2 protection diodes D 50 Kg/490 N 24 Vcc 45 ma 50 mm 28 mm mm mm Cod ,45 Kg N 2 protection diodes D 100 Kg/980 N 24 Vcc 100 ma 60 mm 32,5 mm mm mm Cod ,43 Kg N 2 protection diodes D 100 Kg/980 N 24 Vcc 100 ma 60 mm 32,5 mm mm mm Cod ,68 Kg N 2 protection diodes Accessorieses (see page 15) 1353-CSA 1363-CSA 55 mm diameter fl exible keeper plate 60 mm diameter flexible keeper plate 14 Fire System Components Toll Free Number

17 Accessories for electromagnetic door release units 1341-CSA / 1351-CSA / 1361-CSA Flexible keeper plate for electromagnetic door release units Allows an overall plate angular range of 120 Provided with shock absorber Steel plate Black thermoplastic structure 1341-CSA 1351-CSA 1361-CSA A 45 mm 55 mm 60 mm 1343-CSA / 1353-CSA / 1363-CSA Flexible keeper plate joint for electromagnetic door release units Allows an overall plate angular range of 30 Reduced size Provided with shock absorber Steel plate Black thermoplastic structure 1343-CSA 1353-CSA 1363-CSA A 45 mm 55 mm 60 mm 13ST15 / 13ST25 Bracket for either floor or wall mounting of electromagnets of the Series and Steel sheet structure White epoxy varnishing Description Pc./pack. Package weight Applicability 1341-CSA Flexible keeper plate ø45 mm white 1 0,13 Kg Series CSA Flexible keeper plate ø45 mm white 1 0,11 Kg Series CSA Flexible keeper plate ø55 mm black 1 0,17 Kg Electromagnetic door release units from 25 to 50 Kg (excluding 1365 and 1367) 1353-CSA Flexible keeper plate ø55 mm black 1 0,15 Kg Electromagnetic door release units from 25 to 50 Kg (excluding 1365 and 1367) 1361-CSA Flexible keeper plate ø60 mm black 1 0,21 Kg 100 Kg electromagnetic door release units 1363-CSA Flexible keeper plate ø60 mm black 1 0,19 Kg 100 Kg electromagnetic door release units 13ST mm bracket for wall/floor mounting 1 0,50 Kg Series Series ST mm bracket for wall/floor mounting 1 0,65 Kg Series Series REMOTE CONTROL OF ELECTROMAGNETIC DOOR RELEASE UNITS Further than from the central panel and from possible local unlocking buttons, electromagnetic door release units can also be unlocked by operating a remote button or control cabinet. The following codes can be used to this aim: 2495-CSA and 2498-R (see the Intrusion System Components catalogue). Fire System Components Toll Free Number

18 Sign boards Aluminium sign board Series 1500 Aluminium frame 12/24 Vcc power supply Steady or flashing light Recessed mounting (with accessory) Equipped with a piezoelectric buzzer Sign board available in various versions, suited to any risk condition such as fi re, fl ooding, gas leaks, etc., whenever visual and acoustic information are needed. The versions equipped with high brightness LEDs ensure the highest light effi ciency and limited current draw, therefore allowing to reduce the usage of additional power supply stations. Its classic design and the metallic aluminium frame make it specifi cally suited to industrial and commercial installations. The sign board is provided with the standard writing FIRE ALARM, while different writings are available as Accessories on page 20. Housing material Screen material Connection type Operating Temperature Aluminium with white epoxy varnishing Self-extinguishing polycarbonate Terminals Protection degree IP 30 Buzzer characteristics -10 C +50 C Buzzer sound pressure: at 1 m V V Frequency 3200 Hz Pulsating sound: 0,25 s ON - 0,25 s OFF current Lamp Flashing frequency Buzzer Package weight Notes O-1553-CSA O-1554-CSA O-1555-CSA O Vcc 24 Vcc 12 Vca 24 Vca 12 Vcc 24 Vcc from 10,8 Vcc to 28 Vcc 12 Vcc 24 Vcc 12 Vca 24 Vca Vcc Vcc Vca Vca Vcc Vcc Vcc Vcc Vcc Vcc Vca Vca Xeno flashtube 0,5 J Incandescent 12V - 3W (x4) High brightness LED Xeno flashtube 0,5 J 60 90/min adjustable yes 0,95 Kg Steady light or 60 90/min adjustable yes 1,00 Kg Steady light or 60/min yes 0,95 Kg 60 90/min adjustable * The indicated current is for steady light; with flashing light: Vcc, Vcc. ** Magnetic test: moving the (supplied) magnet close to the area marked with the label, the panel should activate an alarm. yes 2,1 Kg max current buzzer output 40 ma With magnetic test** and active line control LED Double-face with lateral fixing Accessories (see on page 21) 1590-CSA Flush mounting case for sign boards of the series 1500 O Fire System Components Toll Free Number

19 Sign board Thermoplastic sign board Series 5000 Thermoplastic self-extinguishing frame 12/24 Vcc and 230 Vca power supply Steady or flashing light High sound power buzzer Self-powered versions are available (with batteries) Optical/acoustic sign boards, suited to any risk condition such as fi re, fl ooding, gas leaks, etc., whenever visual and acoustic information are needed. The notably elegant and pleasing design is suited to installations in hotels, shops, shopping centres, cinemas. Self-powered models are equipped with a buffer Ni-Cd battery to power the equipment in alarm conditions (independently, therefore, from any other type of external power supply). Housing material White coloured thermo-plastic self-extinguishing (hot wire 850 C) Screen material Self-extinguishing transparent polycarbonate Connection type Terminals Operating Temperature -10 C +50 C (+5 C +50 C when self-powered) Protection degree IP 40 Buzzer sound pressure: at 1 m V db Buzzer 24V Frequency 3200 Hz Pulsating sound: 0,25 s ON - 0,25 s OFF The self-powered sign board can be connected to an external 24 Vcc sounder with a maximum current draw of 40 ma Magnetic test function with supplied magnet. Controlled from the central panel at 24 Vcc - 2 ma (either when supplied or in case of power loss). All versions are provided with the standard writing FIRE ALARM, while different writings are available as accessories on page 20. for self-powered sign boards Charging current Lamp Flashing frequency Package weight O-5050-CSA 230 Vca 10 ma incandescent Krypton 3,3V - 1A (x3) /min. adjustable 1,00 Kg O V 24 Vcc 100 ma incandescent Krypton 3,3V - 1A (x3) /min. adjustable 0,95 Kg O-5051-CSA 230 Vca 10 ma 8W fluorescent Steady light 1,00 Kg O V 24 Vcc 100 ma 8W fluorescent Steady light 0,95 Kg O Vca 10 ma 8W fluorescent Steady light 1,00 Kg Controlled by NC/NA contact * With a 40 ma sounder connected (buzzer not connected) the duration reduces to 30 minutes. for non self-powered sign boards Notes current Lamp O-5052-CSA O-5053-CSA O-5054-CSA O-5055-CSA 12 Vcc 24 Vcc 12 Vcc 24 Vcc 12 Vca 24 Vca 12 Vcc 24 Vcc from 10,8 Vcc to 28 Vcc Vcc Vcc Vcc Vcc Vca Vca Vcc Vcc Vcc Vcc Incandescent 12V - 3W (x4) Xeno flashtube 0,5 J Incandescent 12V - 3W (x4) Flashing frequency Steady light 60 90/min adjustable Steady light or 60 90/min adjustable Package weight 0,70 Kg 0,75 Kg 0,75 Kg High brightness LED Steady light or 60/min 0,70 Kg * The indicated current is for steady light; with flashing light: Vcc, Vcc. ** Magnetic test: moving the (supplied) magnet close to the area marked with the label, the panel should activate an alarm. Notes Available upon request 1552 FL flashing kit (see accessories page) max current buzzer output 40 ma With magnetic test** and active line control LED Accessories W Spare battery for self-powered sign boards Fire System Components Toll Free Number

20 Sign boards Sign board IP 65 Series 5500 Thermoplastic self-extinguishing frame Protection grade IP 65 Power supply 12/24 Vcc and 230 Vca Steady or flashing light High sound power buzzer Self-powered versions are available (with batteries) Optical/acoustic sign board for outdoor use available in various versions, suited to any risk condition such as fi re, fl ooding, gas leaks, etc., whenever visual and acoustic information are needed. The IP 65 protection grade allows usage in indoor and outdoor environments, even humid and dusty. Self-powered models are equipped with a buffer Ni-Cd battery to power the equipment in alarm conditions (independently, therefore, from any other type of external power supply). Housing material White coloured thermo-plastic self-extinguishing (hot wire 850 C) Materiale diffusore Self-extinguishing transparent polycarbonate Connection type Terminals Operating Temperature -10 C +50 C (+5 C +50 C when self-powered) Protection degree IP 65 Buzzer sound pressure: at 1 m 100 db Buzzer 12V V Frequency 3200 Hz Pulsating sound: 0,25 s ON - 0,25 s OFF The battery recharge circuit is equipped with a control system with LED indication. The self-powered sign board can be connected to an external 24 Vcc sounder with a maximum current draw of 40 ma. Magnetic test function with supplied magnet. Controlled from the central panel at 24 Vcc 2 ma (either when supplied or in case of power loss). All versions are provided with the standard writing FIRE ALARM, while different writings are available as accessories on page 20. for self-powered sign boards Charging current Lamp Flashing frequency BNi-Cd HT Battery Initial duration Package weight O V 24 Vcc 100 ma 8W fluorescent Steady light 3,6 1,5 Ah 60 min* 1,20 Kg O Vca 10 ma 8W fluorescent Steady light 3,6 1,5 Ah 60 min* 1,25 Kg Controlled by NC/NA contact * With a 40 ma sounder connected (buzzer not connected) the duration reduces to 30 minutes. Notes for non self-powered sign boards current Lamp Flashing frequency Package weight Notes O-5553-CSA O-5554-CSA O-5555-CSA 12 Vcc 24 Vcc 12 Vca 24 Vca 12 Vcc 24 Vcc from 10,8 Vcc a 28 Vcc Vcc Vcc Vca Vca Vcc Vcc Vcc Vcc Xeno fl ashtube 0,5 J Incandescent 12V - 3W (x4) High brightness LED 60 90/min adjustable Steady light or 60 90/ min adjustable Steady light or 60/min * The indicated current is for steady light; with flashing light: Vcc, Vcc. ** Magnetic test: moving the (supplied) magnet close to the area marked with the label, the panel should activate an alarm. 1,00 Kg 0,95 Kg 0,90 Kg max current buzzer output 40 ma With magnetic test** and active line control LED Accessories W Spare battery for self-powered sign boards 18 Fire System Components Toll Free Number

21 Sign boards Sign board IP 54 EN54-3 Compliant Series 5900 Self-extinguishing thermoplastic structure IP54 Protection Degree High power acoustical output CPD certified UNI EN54-3:2001+A1:2002+A2: The optical/acoustic sign board series 5900 is suited to any risk condition such as fi re, fl ooding, gas leaks, etc., whenever visual and/or acoustic information is required. The IP 54 protection degree allows usage in both indoor and outdoor environments, even in humid and dusty conditions, while the high powered internal sounder generates a sound output of 88 db at 1m. The sign board is supplied with the standard message label FIRE ALARM, while other message labels EVACUATE PREMISES and EXTINGUISHING IN PROGRESS are also available to order as accessories. CPD certifi ed in accordance with UNI EN54-3:2001 +A1:2002 +A2:2006. Housing material Self-extinguishing thermoplastic Connection type Terminals Operating Temperature -10 C / +50 C Protection degree IP 54 Acoustical Specifications Sound output 88 db 1m Sound frequency: 2160 Hz ± 30 Hz for panels 5955-CSA current Lamp From 10,8 Vcc a 28 Vcc V V High brightness LED Flash requency Steady light or 60/min Package weight 0,9 Kg Accessories FIRE ALARM EVACUATE PREMISES EXTINGUISHING IN PROGRESS CSA08584 CSA08587 CSA08589 Fire System Components Toll Free Number

22 Available writings for Sign boards Writings for sign boards of the series Writings provided in standard sets as from the table. ITALIAN SET 1550-S1 ITALIAN SET S2 ALLARME INCENDIO ALLARME ANTINCENDIO EVACUARE IL LOCALE SPEGNIMENTO AUTOMATICO IMMINENTE IMPIANTO ANTINCENDIO INTERVENUTO NON ENTRARE VIETATO ENTRARE SPEGNIMENTO AUTOMATICO IMMINENTE NON ENTRARE SPEGNIMENTO IN CORSO SPEGNIMENTO IN CORSO ALLARME GAS ABBANDONARE IL LOCALE FRENCH SET 1550-S4 EVACUATION IMMEDIATE ENTREE INTERDITE EMISSION DE HALO EMISSION DE CO 2 ALLARME INCENDIE ENGLISH SET 1550 S5 FIRE ALARM DO NOT ENTER EXTINGUISHING IN PROGRESS EVACUATE PREMISES IMMEDIATELY GERMAN SET 1550-S5 LÖSCHUNG IN GANG RAUM SOFORT VERLASSEN EINTRITT VERBOTEN FEUERALARM SPANISH SET 1550-S7 ALARMA INCENDIO ALARMA GAS NO ENTRAR HALON DISPARADO SALIR DE LOCAL DISPARO DE HALON IMMEDIATO Writings for sign boards of the series Adhesive writings available individually. ITALIAN FRENCH ENGLISH GERMAN SPANISH PORTUGUESE MISCELLANEOUS ALLARME INCENDIO ALLARME GAS ALLARME SPEGNIMENTO IN CORSO ABBANDONARE IL LOCALE VIETATO ENTRARE SPEGNIMENTO AUTOMATICO IMMINENTE EVACUARE IL LOCALE SPEGNIMENTO AUTOMATICO IMMINENTE CSA08660 CSA08661 CSA08662 CSA08663 CSA08664 CSA08588 CSA08659 ALLARME INCENDIE EVACUATION IMMEDIATE ENTREE INTERDITE CSA08670 CSA08671 CSA08672 HAZARDOUS AREA EXTINGUISHING IN PROGRESS ALARM FIRE ALARM DO NOT ENTER DOOR CLOSING CSA08665 CSA08666 CSA08667 CSA08668 CSA08669 CSA0866A EINTRITT TIEFGARAGE BETRETEN VERBOTEN FEUERALARM SOFORT VERBOTEN VERLASSEN GASALARM CSA08673 CSA08674 CSA08675 CSA08676 EXTINCION DISPARADA MONOXIDO DE CARBONO GAS DISPARADO FUEGO INCENDIO ATMOSFERA PELIGROSA CSA08677 CSA08678 CSA08679 CSA08682 CSA08684 CSA08689A EXTINCAO ACTUADA ATMOSFERA PERIGOSA ATMOSFERA EXPLOSIVA FOGO CSA08688 CSA08689 CSA08689B CSA08683 FIRE INCENDIO NON ENTRARE DO NOT ENTER EVACUAZIONE EVACUATION VIETATO FUMARE VIETATO FUMARE GUASTO IMPIANTO DI VENTILAZIONE AREA FUMATORI CSA08653 CSA08643 CSA08642 CSA08645 CSA08646 CSA08647 Writings for sign boards of the series Adhesive writings available individually. ITALIAN FRENCH ENGLISH PORTUGUESE SPANISH ITALIAN ALLARME INCENDIO ALLARME ABBANDONARE IL LOCALE CSA08660W CSA08662W CSA08664W EVACUATION IMMEDIATE CSA08671W ALARM ENTREE INTERDITE CSA08672W FIRE ALARM PLEASE EVACUATE CSA08667W CSA08668W CSA08691W ATMOSFERA PERIGOSA ATMOSFERA EXPLOSIVA FOGO CSA08689W CSA08689BW CSA08683W EXTINCION DISPARADA GAS DISPARADO FUEGO INCENDIO ATMOSFERA PELIGROSA CSA08677W CSA08679W CSA08682W CSA08684W CSA08689AW ALLARME INCENDIO ALLARME ALLARME GAS ABBANDONARE IL LOCALE VIETATO ENTRARE SPEGNIMENTO AUTOMATICO IMMINENTE CSA08584 CSA08585 CSA08586 CSA08587 CSA Fire System Components Toll Free Number

23 Accessories for Sign boards 1552-BZ High performance piezoelectric buzzer Voltage: 3 24 Vcc Current: Vdc, Vdc Frequency: 3200 Hz ± 100 Hz Pulsating sound 0,25 s ON, 0,25 s OFF Sound pressure at 1 m: Vcc, Vdc Wired connection Operating temperature: -20 C +60 C Complete with brackets for fixing inside the case of the series CSA For recessed sign boards of the series 1500 In galvanized sheet iron Visible frame with white epoxy varnishing Dimensions of wall recessed space 320 x 105 mm Description Pc./package. Package weight Applicability 1552-BZ Piezoelectric buffer with pulsating sound 1 0,02 Kg 1590-CSA Recessed case for sign boards of the series ,10 Kg Series 1500 (excluding 1586/81) Fire System Components Toll Free Number

24 Call points Call point EN54-11 Series CXM Restorable and glass break versions Protection Grade IP 54 and IP 66 Operation test with the supplied key CPD certificate EN54-11:2001+A1: Call point for the manual signalling of fi res in compliance with the EN54-11 regulation. The IP 54 indoor model is provided with a restorable element and a glass element. In the glass breaking version, by pressing the centre of the glass (protected by a safety fi lm) it will break off while activating the alarm. In the restorable version by pressing the centre of the plastic element the alarm will be activated and signalled by the change of colour in the upper zone of the element. The supplied key, further than allowing restoration of the button (in the restorable version), also has the functions of test key and a tool for opening the button. The silk screen printing is universal with the press the centre and house in fi re symbols. Available as an accessory is the protection lead sealing door with clamp. CPD certifi cate according to UNI EN54-11:2001 +A1:2005. (only IP 66 versions) Housing material Operation Connection type Operating Temperature Standard equipment Thermoplastic, red colour Direct 6 terminals (3 double terminals for shunt) -10 C +55 C for IP 54 versions -25 C +70 C for IP 66 versions Restore, test and opening keys Contacts Max contact current Max contact Test Element Protection grade Package weight FUL-0048XC 1 cross-over 3 A 9 30 Vcc Yes restorable/glass break IP 54 0,20 Kg FULL-0122X 1 cross-over 3 A 9 30 Vcc Yes glass break IP 66 0,32 Kg FULL-0174X 1 cross-over 3 A 9 30 Vcc Yes Restorable IP 66 0,32 Kg Accessories FULL-5017 Spare glasses for call points of the series CXM - (10pc./package) FUL-0156 Doors with clamp - (10pc./package) FUL-0045 Restorable glasses for call points of the series CXM -(10pc./package.) Call point with door and clamp FUL Fire System Components Toll Free Number

25 Call points Glass break call point Series 2495 Protection grade IP 54 White and green versions Dual cross-over contacts Signalling LED Glass break call point with direct operation (the glass breaking automatically determines the activation of the alarm). The glass, to be broken by simply pressing on it, is equipped with a specifi c safety fi lm with normalised universal silk screen print. In order to restore the button it is necessary to replace the glass. Available in white and green colours. Housing material Thermoplastic, colours as from the table Door material Transparent thermoplastic Operation Direct Connection type Screw binding post Operating Temperature -10 C +50 C Protection degree IP 54 Contacts Max. contacts current Max contacts LED Colour Package weight 2495-V 2 crossover 3 A 75 Vcc Yes Green 0,18 Kg 2495-CSA 2 crossover 3 A 75 Vcc Yes White 0,18 Kg Accessories 2472-U Spare glass for call points of the series (10pc./package.) 2495-CSA Fire System Components Toll Free Number

26 Bells Classic bell Series GONG For indoor use Steel dome High efficiency power drive Low current consumption Diameters 4,6 Power supply at 12 or 24 Vcc UNI EN54-3:2000+A1: Classic bell for fi re alarm, security, industrial systems and other signalling purposes. The internal power driven movement, with pinion and pin attached to the external steel bell, produces a powerful sound with a low current consumption. The larger the diameter of the bell the higher the acoustic effi ciency. Two different diameters are available for the bell, 4 and 6 inches. The smaller bell (4 inches) is generally used in hotel rooms or in small size environments, while the larger one is used in industries, warehouses and shop centres to indicate the presence of a fi re. The power supply terminals are doubled in order to facilitate installation. The bells are equipped with two diodes for the line monitoring system. CPD certifi cate in accordance with UNI EN54-3:2000 +A1:2002. Dome material Red coloured enamelled steel Base material Black coloured polycarbonate Connection type Terminals n. 4 x 2,5 mm 2 Operating Temperature -10 C +50 C Protection degree IP 42 Diameter current Allowed Acoustic pressure at 1 m Diameter A Height B Package weight LOGO inches 24 Vcc 18 ma Vcc 84 db 112 mm 55 mm 0,45 Kg LOGO inches 24 Vcc 25 ma Vcc 93/95 db 152 mm 60 mm 0,85 Kg 24 Fire System Components Toll Free Number

27 Bells Electronic bell IP 55 Series F-Bell For outdoor use Steel dome diameter 6 Integrated control circuit Low current consumption IP o 24 Vcc UNI EN54-3:2000+A1: Red coloured 6 electronic bell for fi re alarm, security, industrial systems and other signalling purposes. By combining a miniaturised solenoid with an integrated control circuit it allows excellent acoustic performance, very low current consumption and a high reliability. The installation is fast and easy thanks to the dome s snap action hook and the doubled power supply terminals. Available with 12 or 24 Vcc power supply s. The IP 55 protection degree allows usage in outdoor environments although the aesthetics, especially elegant, makes it suited to the most prestigious indoor environments too. CPD certifi cate in accordance with UNI EN54-3:2000 +A1:2002. Dome material Red coloured enamelled steel Base material Black coloured polycarbonate Connection type Terminals n. 4 x 2,5 mm 2 Operating Temperature -10 C +55 C Protection degree IP 55 Diameter current Allowed Acoustic pressure at 1 m Package weight FULL inches 12 Vcc 55/65 ma 9 15 Vcc 95 db 1,1 Kg FULL inches 24 Vcc 25/35 ma Vcc 95 db 1,1 Kg Fire System Components Toll Free Number

28 Sounders Electronic sounder Series ROLP 32 selectable tones Second tone for two-stage alarms Volume adjustment IP 54 and IP 65 versions Power supply at 9 and 28 Vcc UNI EN54-3:2000+A1: Electronic sounder for fi re alarm systems characterized by a high sound power and reduced consumption. The specifi cally compact aesthetics makes it ideal in environments of any type. The internal electronics is covered with polyurethane resin to ensure a high degree of protection and robustness Available in the IP 54 (thin base) e IP 65 (tick base) version. Installation is made simple thanks to the bayonet coupling on the relevant base and to doubled terminals which allows shunting of the connections. The ROSHNI sounder is equipped with 32 dip-switch selectable tones (out of which 6 are CPD certifi ed) and with volume adjustment. CPD certifi cate according to UNI EN54-3:2000 +A1:2002. Housing material Connection type Operating Temperature Red coloured thermoplastic Double terminals (6) for shunting -25 C +70 C current Allowed Acoustic pressure at 1 m N tones Height A Protection degree Package weight FULL-0389X Vcc 32 ma max 9 28 Vcc Vcc mm IP 54 0,24 Kg FULL-0403X Vcc 32 ma max 9 28 Vcc Vcc mm IP 65* 0,34 Kg For the tones please refer to the Sounder Tones Table on page 29. * To obtain the reported protection grade use a suitable cable gland. Accessories FULL-0027 Thin red base (IP 54) FULL-0059 Thick red base (IP 65) 26 Fire System Components Toll Free Number

29 Sounders Electronic sounder for ceiling Series SQUASHNI MICRO Ceiling mount installation Exceptionally thin Prepared for fire detector mounting For 12 and 24 Vcc systems UNI EN54-3:2000+A1: Electronic sounder for ceiling mounting characterized by a high sound power and reduced consumption. The specifi cally compact aesthetics makes it ideal in environments of any type. The internal electronics is covered with polyurethane resin to ensure a high degree of protection and robustness. Installation is made simple thanks to the rapid of the front cover and to doubled terminals which allows shunting of the connections. The ROSHNI sounder is equipped with 4 dip-switch selectable tones and with volume adjustment. Available in the red and white colours. CPD certifi cate according to UNI EN54-3:2000 +A1:2002. Housing material Connection type Operating Temperature Red or white coloured thermoplastic 6 terminals -10 C +55 C current Allowed Acoustic pressure at 1 m N tones Colour Protection degree Package weight FULL-0111X Vcc 15 ma max 9 30 Vcc Vcc 4 Red IP 42 0,16 Kg FULL-0110X Vcc 15 ma max 9 30 Vcc Vcc 4 White IP 42 0,16 Kg For the tones please refer to the sounder tones table on page FULL-0174X Fire System Components Toll Free Number

30 Sounders Trumpet electronic sounder Series SYMPHONI HO Very high efficiency 32 selectable tones For indoor use Sound emission up to 120 db For 12 and 24 Vcc systems UNI EN54-3:2000+A1: Electronic sounder for ceiling mounting characterized by a high sound power and reduced consumption. Thanks to the high sound emission, up to 120dB, it is recommended in large environments or in environments with a high background noise. The internal electronics is covered with polyurethane resin to ensure a high degree of protection and robustness. Back case with double cable input and double terminals for the shunting of the connections. The SYMPHONY sounder is equipped with 32 dip-switch selectable tones (out of which 6 are CPD certifi ed) and with volume adjustment. CPD certifi cate according to UNI EN54-3:2000 +A1:2002. Housing material Red or white coloured thermoplastic Connection type Terminals Operating Temperature -10 C +55 C Protection degree IP 42 current Allowed Acoustic pressure at 1 m N tones Colour Protection degree Package weight FULL-0009X Vcc 260 ma 9 28 Vcc 120 db* 32 rosso IP 42 0,58 Kg For the tones refer to the sounder tone table at page 29. * With tone n Fire System Components Toll Free Number

31 Sounder tones table First tone Second tone Dip Switches Alternate 800/970 Hz 2 Hz (250ms-250ms) BS Fire Sweep 800~970 Hz, 7 Hz (7/s) BS Fire Sweep 800~970 Hz, 1 Hz (1/s) BS Fire Tone Applications Continuous at 2850 Hz, Steady General purpose Sweep 2400~2850 Hz, 7 Hz General purpose Sweep 2400~2850 Hz, 1 Hz General purpose Slow whoop 500~1200 Hz, 3s sweep, 0.5 s silence, then repeat Dutch fire (NEN 2575) Sweep 1200~500 Hz, 1 Hz German fire (DIN ) Alternate 2400 & 2850 Hz, 2 Hz (250ms-250ms) General purpose Intermittent 970 Hz, 0.5 Hz (1s On/1s Off) PFEER alert Alternate 800 & 970 Hz, 1 Hz (500ms-500ms) BS Fire Intermittent 2850 Hz, 0.5 Hz (1s On/1s Off) General purpose Intermittent 970 Hz, 0.8 Hz (250ms On/1s Off) General purpose Continuous a 970 Hz, Steady PFEER toxic gas Alternate 554 & 440 Hz, 100ms-400ms French fire (NFS ) Intermittent 660 Hz, 3.3 Hz (150ms On/150msOff) Swedish (Air Raid) Intermittent 660 Hz, 0.28 Hz (1.8s On/1.8s Off) Swedish (Local warning) Intermittent 660 Hz, 0.05 Hz (13s Off / 6.5Hz On) Swedish (Pre-mess) Continuous 660 Hz, Steady Swedish (All clear) Alternate 554 & 440 Hz, (1s On/1s Off) Swedish (Turn out) Intermittent 660 Hz, 1 Hz (500ms-500ms) Swedish general purpose Intermittent 2850 Hz, 4 Hz (150ms On/100ms Off) Pelican crossing Sweep 800~970 Hz, 50 Hz BS Fire Sweep 2400~2850 Hz, 50 Hz General Purpose Intermittent 970 Hz, 3 x 500ms pulses, 1.5s silence, then repeat ISO Intermittent 800~970 Hz, 3 x 500ms pulsed sweep, 1.5s silence, then repeat ISO Intermittent 970 & 800 Hz, 3 x 500ms pulsed sweep, 1.5s silence, then repeat ISO Alternate 800 & 970 Hz, 2 Hz (250ms-250ms) BS Fire Hz Alternate 990 & 650 Hz, 2 Hz (250ms-250ms) (Symphony tones) BS Fire Hz Alternate 510 & 610 Hz, 2 Hz (250ms-250ms) (Squashing Micro tones) BS Fire Sweep 300~1200 Hz, 1 Hz General Purpose Hz Alternate 510 & 610 Hz, 1 Hz (500mS-500mS) BS Fire 33 Continuous 990 Hz 34 Intermittent 990 Hz, 0.5 s On / 0.25 s Off 35 Continuous 510 Hz 36 Intermittent 510 Hz, 1 Hz (500mS-500mS) Applicability of the tones Series Available tones FLASHNI Two alarm/pre-alarm tones ROLP From 1 to 32 (selectable by Dip Switches) SQUASHNI MICRO 3 & 30, 35, 36 SYMPHONI HO From 1 to 32 (selectable by Dip Switches) Sounder connection scheme with second tone Positive Negative Second tone Optional Next sounder Fire System Components Toll Free Number

32 Combined sounders and beacon Combined sounder and beacon FS24 Dual tone combined sounder and beacon High sound power LED illuminated signalling For indoor use High quality/price ratio UNI EN54-3:2000+A1:2002+A2: Dual tone sounder with a high acoustic power with LED beacon. The specifi cally elegant aesthetics and the reduced dimensions make this sounder suited to both residential and commercial environments. Defi nitely limited current consumption. Doubled terminals for the shunting of connections. Adhesive writings are provided with the equipment to be applied on the beacon dome. CPD certifi cate according to UNI EN54-3:2000+A1:2002+A2:2006. Housing material Red coloured thermoplastic Dome material Red coloured transparent thermoplastic Connection type Double terminals (4) for shunting Dual tone frequency 450Hz-550Hz ± 10% Operating Temperature -5 C +50 C Protection degree IP 30 Standard equipment Adhesive writings current Acoustic pressure at 1 m Lamp Beacon frequency Colour Package weight Notes O-FS24 24 Vcc 60 ma 95 db High brightness LED 110 / min rosso 0,46 Kg With adhesive labels* * Writings supplied with the equipment: INCENDIO, FIRE, FUEGO, FOGO 30 Fire System Components Toll Free Number

33 Combined sounders and beacons Combined sounder and beacon for outdoor use Series FLASHNI High quality Second tone for two-stage alarms Xeno flashtube Volume adjustment For indoor and outdoor use 12 and 24 Vcc UNI EN54-3:2000+A1: Electronic sounder with Xeno fl ashtube beacon for fi re detection systems. Derives from the combination of the Roshni sounder with a powerful Xeno fl ashtube, while maintaining very limited dimensions and a reference aesthetic result. The optical part has a very high effi ciency thanks to the Fresnel lens, while the acoustic part provides 2 separate tones (CPD certifi ed) for alarm / pre-alarm and volume adjustment (0, 20dB). Available in the IP 54 and IP 65 versions for use in indoor and outdoor environments. The whole electronics is encapsulated in a polyurethane resin to ensure a high degree of protection of the device and a remarkable robustness. Compatible with the sounder bases of the Roshni series. CPD certifi cate according to UNI EN54-3:2000 +A1:2002. Housing material Lens material Connection type Operating Temperature Thermoplastic, red colour Polycarbonate, red colour Double terminals (6) for shunting -10 C +55 C current Allowed Acoustic pressure at 1 m Lamp Beacon frequency Height A Protection degree Package weight FULL-0246X 24 Vcc 68 ma Vcc 110 db Xeno 0,7 J 60 / min 91 mm IP 54 0,34 Kg FULL-0238X 24 Vcc 68 ma Vcc 110 db Xeno 0,7 J 60 / min 91 mm IP 65* 0,37 Kg FULL Vcc 86 ma 9 15 Vcc 104 db Xeno 0,7 J 60 / min 120 mm IP 65* 0,37 Kg * To obtain the reported protection grade use a suitable cable gland. Accessories FULL-0027 Thin red base FULL-0059 Thick red base FULL-0118 Thin white base FULL-0017 Thick white base Fire System Components Toll Free Number

34 Beacons Metallic base beacon 1478/1481 Xeno flashtube Aluminium base IP 65 For indoor and outdoor use 12 and 24 Vcc Output for external sounder Die-cast beacon with aluminium base and a high protection grade. The Xeno fl ashtube and the internal mirror provide a high light performance and a low current consumption. The beacon frequency can be adjusted by internal trimmer and the permitted power supply is 12 or 24 Vcc or Vca. The high protection grade and the guaranteed robustness of the aluminium base make this beacon suited to usage in outdoor and/or industrial environments. For the connection to the internal terminals an input threaded 3/8 gas cableway is available. Output for supplying power to external sounders. Base material Die-cast aluminium with epoxy varnishing Dome material Thermoplastic Connection type Terminals Operating Temperature -10 C +50 C Protection degree IP 65 Standard equipment Cap for cableway input current Lamp Beacon frequency Base colour Dome colour Package weight Notes 1478-CSA 1481-CSA 12 Vcc 24 Vcc 12 Vca 24 Vca 12 Vcc 24 Vcc 12 Vca 24 Vca Vcc Vcc Vca Vca Vcc Vcc Vca Vca Xeno flashtube 0,5 J Xeno flashtube 0,5 J / min adjustable / min adjustable Red Red 0,42 Kg White Orange 0,42 Kg Max current at buzzer output 40 ma Max current at buzzer output 40 ma 32 Fire System Components Toll Free Number

35 Beacons Warning light Series 1483/1486 Xeno flashtube or incandescent lamp Flashing or steady light Base in thermoplastic material IP 55 For indoor and outdoor use 12 or 24 Vcc Various colours available Output for external sounder Warning light in thermoplastic material with Xeno fl ashtube or incandescent lamp. The version with incandescent lamp can be adjusted to emit either a steady or a fl ashing light, while the version with Xeno fl ashtube is characterized by high light performance at a low current consumption. The high protection grade makes this warning light suited to outdoor usage as well. Available in various colours. Output for supplying power to external sounders. Base material Thermoplastic Dome material Thermoplastic Connection type Terminals Operating Temperature -10 C +50 C Protection degree IP 55 current Lamp Beacon frequency Base colour Dome colour Package weight Notes 1483-CSA 1483-CT 1484-CSA 1486-CSA 12 Vcc 24 Vcc 12 Vca 24 Vca 12 Vcc 24 Vcc 12 Vca 24 Vca 12 Vcc 24 Vcc 12 Vca 24 Vca 24 Vcc Vcc Vcc Vca Vca Vcc Vcc Vca Vca Vcc Vcc Vca Vca 200 ma steady light 100 ma flashing light Xeno 0,5 J Xeno 0,5 J Xeno 0,5 J Incandescent 12 V - 5 W - Ba 15s / min adjustable / min adjustable / min adjustable Steady light or 60 / min White Orange 0,21 Kg White Transparent 0,21 Kg Red Red 0,21 Kg Red Red 0,19 Kg Max current at buzzer output 40 ma Max current at buzzer output 40 ma Max current at buzzer output 40 ma Fire System Components Toll Free Number

36 Beacons Prism warning light 1489 Incandescent lamp or LED Base in thermoplastic material IP 55 For indoor and outdoor use 12 or 24 Vcc Warning light in thermoplastic material with prism screen. Supplied with incandescent lamp and adjustable steady or fl ashing operation. Permissible power supply at 12 or 24 Vcc. Protection grade IP 55, suited for use in both indoor and outdoor environments. Base material Thermoplastic Cover material Thermoplastic (same colour of the base) Dome material Thermoplastic Connection type Terminals (Wired for 1489 CL) Operating Temperature -10 C +50 C Protection degree IP 55 Standard equipment Lamp 12 V - 3 W, Lamp 24 V - 3 W 1489-CSA Vcc current Vcc* Vcc* Lamp Incandescent 12 V - 3 W o 24 V - 3 W Beacon frequency Steady light or 60 / min Base colour * The reported figures are average values related to the flashing operation, with steady light: Vcc, Vcc Dome colour Package weight Red Red 0,15 Kg 34 Fire System Components Toll Free Number

37 Beacons High efficiency beacon Series SOLEX Xeno flashtube Low current consumption Automatic synchronization Various colours available Protection grade IP 54 and IP 65 For indoor and outdoor use High effi ciency beacon with Xeno fl ashtube. Its functionalities, such as the wide range of power supply from 9 to 60 Vcc, the automatic synchronisation and especially the very limited consumption make SOLEX the ideal solution for any type of optical signalling. The bayonet base is designed to simplify the mounting and is also compatible with the sounders of the ROSHNI and FLASHNI series. Two different types of bases are available, the thin model (65 mm) allows unobtrusive installation with a minimal visual impact and an IP 54 protection grade, the thick model (93 mm) instead provides an installation with an IP 65 protection grade. The SOLEX beacons are available with domes in various colours (red, amber, blue, green). A model with tamper protection is also available. Base material Dome material Connection type Operating Temperature Thermoplastic Polycarbonate Double terminals (4) for shunting (6 terminals for code FULL C / +70 C Power supply current Lamp Beacon frequency Height A Base colour Dome colour Protection degree Package weight FULL Vcc 88mA@24 Vcc Xeno 10cd 1 Hz 65 mm Red Red IP 54 0,15 Kg FULL Vcc 88mA@24 Vcc Xeno 10cd 1 Hz 93 mm Red Red IP 65 ** 0,18 Kg FULL Vcc 88mA@24 Vcc Xeno 10cd 1 Hz 65 mm White Amber IP 54 0,15 Kg FULL Vcc 88mA@24 Vcc Xeno 10cd 1 Hz 65 mm White Amber IP 54 0,15 Kg with tamper FULL Vcc 88mA@24 Vcc Xeno 10cd 1 Hz 93 mm White Amber IP 65 ** 0,18 Kg FULL Vcc 88mA@24 Vcc Xeno 10cd 1 Hz 65 mm White Blue IP 54 0,15 Kg FULL Vcc 88mA@24 Vcc Xeno 10cd 1 Hz 93 mm White Blue IP 65 ** 0,18 Kg FULL Vcc 88mA@24 Vcc Xeno 10cd 1 Hz 65 mm White Green IP 54 0,15 Kg FULL Vcc 88mA@24 Vcc Xeno 10cd 1 Hz 93 mm White Green IP 65 ** 0,18 Kg ** The IP 65 protection grade is only ensured when using suitable cable glands. Notes Accessories FULL-0027 Thin red base FULL-0059 Thick red base FULL-0118 Thin white base FULL-0017 Thick white base Fire System Components Toll Free Number

38 Optical and optical-acoustic repeaters Optical-acoustic repeater Series 1420 Wall or recessed mounting Red, green, yellow LED Power supply at 12 or 24 Vcc Very low current draw Optical-acoustic versions (with Buzzer) Optical and optical-acoustic repeater with low current draw LED suited to a wide range of applications in signalling alarms, anomalies, on-off, traffic lights, etc. Combinations of red, green or yellow LED elements and the buzzer are available up to a max of three elements. The light of the LEDs, having a wide visibility angle, can be steady or blinking to be selected by an internal jumper, while the buzzer provides a continuous sound of suitable power. They are aesthetically well integrated with the most used switch frames and available in both the wall mounting and recessed versions with a box of Bticino 503 type (version I). Housing material White coloured thermoplastic Front panel material Anodised aluminium Connection type Wire terminals (2 per each element) Buzzer characteristics 75 db at 50 cm continuous sound 3300 Hz Operating Temperature -20 C +60 C Protection degree IP 40 Housing Front Front Housing Current LED Current Buzzer Buzzer LED colour Blinking frequency Package weight 1423CSA 24 Vcc 10 ma per LED - No Red + green + yellow Steady light or 60/min 0,11 Kg Vcc 10 ma per LED - No Red + green + yellow Steady light or 60/min 0,11 Kg 1423-BZ 24 Vcc 10 ma per LED 12 ma Yes Red + green Steady light or 60/min 0,13 Kg 1423-BZ Vcc 10 ma per LED 12 ma Yes Red + green Steady light or 60/min 0,13 Kg 1423-BZ-I 24 Vcc 10 ma per LED 12 ma Yes Red + green Steady light or 60/min 0,13 Kg recessed Notes 36 Fire System Components Toll Free Number

39 Optical and optical-acoustic repeaters Optical and optical-acoustic repeaters Series 1490 High quality/price ratio Compact size High visibility red, green and yellow LED Power supply at 12 and 24 Vcc Optical-acoustic versions (with Buzzer) Compact size and low current draw optical-acoustic repeater for the remote signalling of alarms, anomalies or else by means of high visibility LEDs. Suited for the joint use with smoke and/or thermal detectors installed in false ceilings or fl oating fl oors, whenever external signalling is required. The versions with the BZ suffi x are equipped with an internal buzzer for the optical-acoustic signalling, with either a steady sound or a beacon. The device can be supplied at both 12 and 24 Vcc. Available in red, yellow, and green colour, it is equipped with a wide light diffusion to be easily visible from any direction. Installation is quick and simple thanks to the terminal connections and the possibility of fi xing the device using the supplied double-sided tape. Housing material Connection type White coloured thermoplastic Terminals Buzzer characteristics 75 db at 30 cm continuous or pulsating sound 2300 Hz, 0.5s On 0.5s Off Operating Temperature -20 C +60 C Protection degree IP 40 Standard equipment Double-sided tape for fixing 2 pc. / package Current LED Current Buzzer Buzzer LED colour Blinking frequency Package weight O-1490-R Vcc 10 ma - No Red Steady light 0,06 Kg O-1490-V Vcc 20 ma - No Green Steady light 0,06 Kg O-1490-G Vcc 20 ma - No Yellow Steady light 0,06 Kg O-1490-CR Vcc 10 ma* - No Red Steady light or 60/min 0,06 Kg O-1490-CV Vcc 20 ma* - No Green Steady light or 60/min 0,06 Kg O-1490-CG Vcc 20 ma* - No Yellow Steady light or 60/min 0,06 Kg O-1490-BZR Vcc 10 ma* 20 ma* Yes Red Steady light or 60/min 0,07 Kg O-1490-BZV Vcc 20 ma* 20 ma* Yes Green Steady light or 60/min 0,07 Kg O-1490-BZG Vcc 20 ma* 20 ma* Yes Yellow Steady light or 60/min 0,07 Kg * With intermittent operation the average current consumption is down by half.. Fire System Components Toll Free Number

40 Optical and optical-acoustic repeaters Optical-acoustic repeater Series 1491 High visibility red, green and yellow LED Power supply at 12 and 24 Vcc Versions with Buzzer Compact size and low current draw optical-acoustic repeater for the remote signalling of alarms, anomalies or else by means of high visibility LEDs. Suited for the joint use with smoke and/or thermal detectors installed in false ceilings or fl oating fl oors, whenever external signalling is required. The device can be supplied at both 12 and 24 Vcc. Available in red and green colour, it is equipped with a wide light diffusion to be easily visible from any direction. Versions with and without buzzer. Without buzzer With buzzer Housing material Connection type White coloured thermoplastic Terminals Buzzer characteristics 65 db at 1 m pulse 2300 Hz 0,5s On - 0,5s Off Operating Temperature -10 C +60 C Protection degree IP 40 LED current Overall consumption Buzzer LED colour Blinking frequency Package weight FUL Vcc 10 ma - No Red 60/min 0,08 Kg FUL Vcc 10 ma V Yes Red 60/min 0,1 Kg 38 Fire System Components Toll Free Number

41 Key boxes and disconnecting switches Glass break key box 1492/1493 Die-cast aluminium box Hammer included Version with key assembly Glass break key box, for keeping and making available the operating key for external command blocks in cases of emergency. The key is protected by a glass that must be broken using the specifi c hammer (supplied), the glass breaking is signalled by an internal changeover micro switch. The robust aluminium frame makes this key box suited to any type of indoor environment. The model is equipped with an integrated key assembly with dual changeover contact (overall 6 terminals) and three 3 supplied keys (keys are all identical). For the connection a threaded 3/8 gas cableway is available. Housing material Epoxy varnished die-cast aluminium Connection type Terminals for glass break contact. Solder terminals for key assembly Operating Temperature -10 C +50 C Protection degree IP 40 Standard equipment Test key, external screws in stainless steel, Cableway plug, n. 2 spare glasses Glass break contact Key blocking contact Case colour Package weight 1492-CSA Changeover max 75 Vcc / 3 A - Red 0,51 Kg Changeover max 75 Vcc / 3 A Dual changeover max 75 Vcc / 3 A Red 0,57 Kg N 3 identical keys Notes Accessories 1494-CSA Spare glasses CSA07960 Spare lock for Fire System Components Toll Free Number

42 Key boxes and disconnecting switches Key box 1498 Metal case For keys of any size Key access by lock or glass break Three way protection Red or blue colour Key box suited to contain keys of any size. Complete protection thanks to the vibration sensor able to detect the glass break, the micro switch to detect opening of the lid, the micro switch to detect key removal, all independently connectable to external supervision and/or alarm systems by means of a 6 poles terminal block. Closing and opening is operated by using a key (supplied in two units), in case of emergency the keys can be reached by breaking the glass. Robust metallic frame to make the product suited for installation in any indoor environment. Housing material Epoxy varnished sheet stee Connection type Terminals Operating Temperature -10 C +50 C Protection degree IP 30 Standard equipment Set of 2 keys for opening the lid 1498-CSA Lid opening contact NC max 75 Vcc / 3 A Key removal contact NC max 75 Vcc / 3 A Glass break sensor * silk screen print: IN CASE OF EMERGENCY BREAK THE GLASS AND TAKE THE KEY Case colour Package weight Notes Mercury glass bulb Red 0,75 Kg Silk screen printed glass* Accessories 1498-VR Spare glass - 1 pc./package CSA06632 Spare lock for the Series Fire System Components Toll Free Number

43 Key boxes and disconnecting switches Key operated disconnecting switch 2490 Dual changeover contact Operated using a key Leaden seal protection door Round key operated disconnecting switch in a thermoplastic case. The key block is equipped with a dual changeover contact with overall 6 terminals individually accessible. This product is suited to a variety of applications including for instance: opening alarm circuits, blocking devices, etc. The transparent protection door can be lead sealed to act as a deterrent against possible breaking attempts. Housing material Thermoplastic, colours as from the table Door material Thermoplastic transparent Connection type Soldering terminals Operating Temperature -10 C +50 C Protection degree IP 53 Standard equipment Set of three keys (identical for all products) Type of contact Max contact Max contact current Case colour Package weight 2490-CSA Dual changeover 75 Vcc 3 A Red 0,23 Kg Accessories CSA07960 Spare lock for the Series 2490 Fire System Components Toll Free Number

44 Ex articles Metal explosion-proof call point Series 1460 Glass break Explosion-proof IP 65 N 2 cableway holes for 3/4 NPT hoses Hammer supplied Versions with direct and indirect activation ATEX Explosion-proof call point for manual signalling of fi res, suited to areas with a potentially explosive atmosphere such as petrochemical industries, pharmaceutical industries, etc. Available in a version with indirect activation (breaking the glass and then pressing the button are both necessary to activate the alarm) and a version with direct activation (breaking the glass is suffi cient to activate the alarm). Available inside are a NO contact and a NC contact with changeover switching. To recover the call point it is necessary to replace the glass. A glass break hammer is supplied. ATEX approval. Housing material Connection type Cableway holes Operating Temperature Protection degree IP 65 Classification and certification Standard equipment Epoxy varnished die-cast aluminium, red colour N. 4 binding post screws 2 x 3/4 NPT -20 C +50 C II 2GD EEx d IIB T6, EEx d IIB+H2 T6 certif. CESI 03 ATEX 050 Hammer Contacts Max contact current Max contact Type of activation Package weight 1460-CSA 1 NA + 1 NC 10 A 380 Vca Indirect 1,1 Kg Italian/English writings 1460-FR-IN 1 NA + 1 NC 10 A 380 Vca Indirect 1,1 Kg French/English writings 1460-A 1 NA + 1 NC 10 A 380 Vca Direct 1,1 Kg Italian/English writings Notes Accessories 1460-VR Spare glass for art pc./package 42 Fire System Components Toll Free Number

45 Explosion-proof articles PX Explosion-proof glass break manual call point in reinforced polyester UV resistant fibreglass red colour With test key Max : 50 Vcc Changeover contact 1 A 50 Vcc, 3 A 30 Vdc 6 terminals connection, cableway: 2xM20 IP 66, strong corrosion resistance Operating temperature: -20 C + 50 C Accessories upon request: Spare glass code 1461 VR Approval ATEX: II 2GD EEx ed IIC T6; BAS 02 ATEX 2105x PX Intrinsically safe electronic sounder Housing material: ABS red colour Voltage 24 Vcc Current consumption 12 ma Sound: 100 db at 1 m, 26 selectable tones 6 terminals connection, cableway: 2xM20 IP 65 Operating temperature: -20 C + 55 C Approval ATEX: I 1G EEx ia IIC T4; BAS 00 ATEX 1259 PX Explosion-proof electronic sounder Material: aluminium varnished body in red colour, diffuser in red ABS Voltage 24 Vcc, Current consumption 250 ma Sound: 103 db at 1 m, 6 selectable tones 6 terminals connection, cableway: 2x20mm ISO IP 66 Operating temperature: -20 C + 55 C Approval ATEX: II 2G EEx d IIB T3; BASEEFA 02 ATEX 0207 PX Intrinsically safe beacon with Xeno flashtube Material: reinforced polyester fibreglass UV resistant body in red colour, transparent PVC dome Voltage 24 Vcc Current consumption 71 ma Flashing: energy 0.5 J, 60 flash / min 8 terminals connection, cableway: 3xM20 IP 66 Operating temperature: -55 C + 60 C Approval ATEX: II 1G EEx ia IIB T4; BAS 02 ATEX 1258x Description Pc./package. Package weight PX Explosion-proof call point in plastic material 1 1,30 Kg 1461-VR Spare glass for PX ,20 Kg PX Intrinsically safe electronic sounder 1 0,36 Kg PX Explosion-proof electronic sounder 1 3,50 Kg PX Intrinsically safe beacon 1 1,60 Kg Fire System Components Toll Free Number

46 Technical info REGULATIONS UNI EN 54-1:1998 EN 54-2 EN 54-3 EN 54-4 EN 54-5 EN 54-7 EN EN EN EN EN EN EN EN EN EN EN EN EN 1155 UNI 9795:2010 UNI Fire detection and fire alarm systems - Introduction Fire detection and fire alarm systems - Control and indicating equipment. Fire detection and fire alarm systems - Fire alarm devices - Sounders; Fire detection and fire alarm systems - Power supply equipment Fire detection and fire alarm systems - Heat detectors - Point detectors. Fire detection and fire alarm systems - Smoke detectors - Point detectors using scattered light, transmitted light or ionization. Fire detection and fire alarm systems - Flame detectors - Point detectors Fire detection and fire alarm systems - Manual call points. Fire detection and fire alarm systems - Smoke detectors - Line detectors using an optical light beam. Fire detection and fire alarm systems - Compatibility assessment of system components Fire detection and fire alarm systems - Guidelines for planning, design, installation, commissioning, use and maintenance Fire detection and fire alarm systems - Voice alarm control and indicating equipment Fire detection and fire alarm systems - Short-circuit isolators Fire detection and fire alarm systems - Input/output devices to be used for transmission patterns of fire detection and signalling systems. Fire detection and fire alarm systems - Aspirating smoke detectors Fire detection and fire alarm systems - Alarm transmission and fault warning routing equipment. Fire detection and fire alarm systems - Components of voice alarm systems - Loudspeakers Fire detection and fire alarm systems - Components using radio links Building hardware - Electrically powered hold-open devices for swing doors - Requirements and test methods Automatic fire detection and fire alarm systems - Design, installation and operation Initial verification and maintenance of automatic fire detection and fire alarm systems IP GRADE Protection grades of the cases envisaged by the CEI regulations are marked by symbols made with the letters IP (Ingress Protection), followed by two digits to indicate respectively the protection against solids (first digit) and against water percolation (second digit). If the case is classified only for one type of protection, the missing digit is indicated by X (e.g.: IP 3X).. Meaning of the digits in the IP grade 1 significant digit protection against the penetration of solids and contacts with energised parts 2 significant digit protection against the penetration of liquids 0 No special protection. 0 No special protection. 1 Protected against solids of larger dimensions than 50 mm. E.g. hands. 1 Protected against vertically falling water drops. 2 Protected against solids of larger dimensions than 12 mm. E.g.. fingers. 2 Protected against vertically falling water drops with a max inclination of Protected against solids of larger dimensions than 2,5 mm. E.g. working tools. 3 Protected against rainfall with inclination up to 60 4 Protected against solids of larger dimensions than 1 mm. E.g. wires or strips. 4 Protected against water splashing from any direction. 5 Protected against the penetration of dust in quantities that are able to cause damages 5 to the equipment. Protected against water jets from any direction. 6 Fully protected against dust 6 Protected against sea water waves or powerful jets. 7 Water-proof upon submergence, the penetration of water in harmful quantities must not be possible. 8 Water-proof upon submergence, the equipment is constantly submerged. The operating environment is classified by the IEC regulations using an abbreviation and one digit based on the examined characteristic (presence of water, solids, temperature, etc.). Below is a table reporting the classification of environments and the minimum Protection Grade for the components used. Environment classification - Presence of water (AD) Environment classification - Presence of solids (AE) IP Abbr. Characteristics Grade AD 1 Negligible presence of water (dry indoor environment) IP X0 AD 2 Presence of condensed steam drops (very humid indoor environment) IP X1 Abbr. AE 1 IP Characteristics Grade Negligible presence of dust and small size solids (houses, schools, IP 0X offices, etc.)) AD 3 Falling water spray (outdoor environment not subject to splashing) IP X3 AE 2 Small size solids IP 3X AD 4 Splashes (splashing subject environment) IP X4 AE 3 Very small size solids IP 4X AD 5 Jets (washing premises) IP X5 IP 5X AE 4 Presence of a significant amount of dust (cement works, granaries, etc.) AD 6 Waves (plants located on quays) IP X6 IP 6X AD 7 Submergence (premises prone to temporary flooding) IP X7 AD 8 Total immersion (underwater premises) IP X8 44 Fire System Components Toll Free Number

47 Technical info FIRE DETECTION SYSTEMS DEFINITIONS The scope of a fire detection system is that of revealing fires as quickly as possible and to provide signalling and indications so that suitable actions can be undertaken. The function of a fire alarm system is that of providing visual and/or acoustic signalling to the occupants of the building who might be subject to the risk of fire. The functions of fire detection and alarming can be grouped into a single system. The EN 54-1 standard specifies the requirements, testing methods and performance criteria of the components of fire detection and signalling systems in buildings. A glossary is reported below relating to fire detection and signalling systems (see also the outline of a fire protection system). Detection Signalling Intervention Typical outline of a fire protection system C = Signalling and control centre A = Power supply equipment R = Fire detectors P = Call points S = Fire alarm devices (sounders, beacons, optical-acoustic boards) T = Remote transmission system F = Electromagnetic door release units E = Automatic extinguishing system Control or signalling central unit. Component of a fire detection and alarm system through which other components can be supplied, performing the following functions: supervision: it supervises the correct operation of the system and signals possible failures through optical and acoustic devices (short circuit, line cut-off, power supply system failure) detection management: it receives signals from the connected detectors, determines if such signals correspond to a fire alarm situation, locate the danger area, and possibly logs all or part of such information signalling and action management: it activates the sound and visual fire alarm devices, sends the alarm to the fire-fighting service, activates the automatic extinguishing systems and the sectioning procedure (electromagnetic door-release units). Fire detector: Component of a fire detection system that contains at least one sensor that constantly or regularly monitors at least one physical and/or chemical phenomenon associated to the fire and that delivers at least one corresponding signal to the control and signalling central unit. The decision to trigger the fire alarm or to activate the automatic fire protection equipment can be taken at the detector or central unit level. The detectors can differ according to the monitored phenomenon (heat, flame, smoke, gas), the way they respond to the variation of the monitored parameter (static, differential, speedometer), the configuration (single-point, multi-point, linear), the resetting mode, the type of transmitted signal (two-stage, multiple state, analogue). Fire alarm device: Component of a fire alarm system used to deliver a fire alarm (e.g. sounder, beacon, optical-acoustical panel). Manual signalling point (manual call point). Component of a fire detection system used to activate a manual alarm. Power supply unit. Component of a fire detection and alarm system that supplies power to the control and signalling central unit and to the components connected to the central unit. Automatic fire-fighting system: Fire-fighting and fire protection equipment (e.g. fixed extinguishing system). Section/Department: Section of a building delimited by construction elements with a predetermined fire resistance and designed to meet the requirements of fire prevention. Point: Component connected to the detection circuit to transmit and receive information about fire detection (fire detectors, manual signalling points). Area: Geographical division of monitored rooms or environments, where one or more points are installed and for which a dedicated area signal method is used for all points. The areas must be delimited in such a way that it is possible to locate, quickly and with no uncertainty, the fire origin. Each area must be provided with at least two manual signalling points. Fire System Components Toll Free Number

48 Technical info Connection elements: All elements that make up the connections between the different components of the detection and alarm system. The cables must be suitably screened if connected to equipment sensitive to electromagnetic interference. The minimum section of supply wires in detectors, manual points etc. must be at least 0.5 mm 2. Interconnections must be carried out (according to CEI 64-8 prescriptions): with wires in piping under mortar or floor; or with wires in exposed piping; or with exposed wires. The wires must be provided with sheathing and laid so as to avoid accidental damage. Connections and shunting must be made inside specific boxes. Interconnection lines must run inside environments monitored by fire detection system. Flying lines are not allowed. In direct current lines (normally used in very low ), the wires must be dimensioned adequately to minimize drop. Knowing the current and the lead resistance, drop can be calculated with the Ohm principle: V = R I where R is total wire resistance. The table indicates the specific resistance of the most used wires. Lead section (mm2) 0,22 0,35 0,50 0,75 1 1,5 2,5 Resistance at 20 C (ohm/km) FIRE DETECTION AND ALARM SYSTEMS: CHARACTERISTICS OF COMPONENTS ELECTROMAGNETIC DOOR RELEASE UNITS When a fire starts the progression of damage to material and immaterial goods is exponential. Therefore, areas affected by the event are restrained through the activation of physical barriers, such as fire-resistant doors that divide the building into separate sections. In normal conditions, such doors are kept open by an electromagnet and allow to control the passage of people and/or means of transport/vehicles. In case of alarm, the release systems are activated to close them (the area required for the door to close must be kept clear). The electromagnet or door-release units an integral part of a system called retaining system for flame-resistant, smoke-resistant doors and other closures. A retaining system consists of at least one fire signaller, e.g. smoke detector, a release unit or signal processing central unit, a retaining device (electromagnet) and an energy source. In case of emergency, the electromagnet releases the door that closes automatically thanks to a closing system (hydraulic door check, spring or counterweight systems), thus preventing the propagation of fire and smoke. Electromagnets are available with retaining strength from a few tens to several hundred kilos, according to the door structure, as well as in different shapes and configurations, for different installation and mounting solutions. Description. The electromagnet normally consists of a coil inside a ferromagnetic core. When the coil is crossed by current, the electromagnet generates a special magnetic field. Approaching a specific iron counter-plate, this is powerfully retained against the core. The attraction power of the system normally depends on the physical dimensions and the magnetic characteristics of the core material, and the current that flows through the coil. Ejector for residual magnetism. It is a counter-plate detaching system generally made up of a central pin with calibrated spring that, with no, allows the door release by eliminating the residual magnetism that would keep the core and counter-plate together. Permanent electromagnetic brake. It exploits the magnetism of a permanent magnet to keep the counter-plate against the core, with no current consumption. In this case, to separate the parts, it is enough to supply to the coil inside the core for a few moments, in such a way that the generated magnetic field has the same intensity as the pre-existing field but opposite polarity, so that the previous field is cancelled. Selection of the electromagnetic brake. To choose the model and the retaining strength of the electromagnet, you must consider the installation site, whether industrial, residential etc. In industrial environments, for instance, the installation of an electromagnet with a higher strength than calculated might prevent undesired release due to impact or vibration owing to the transit of heavy vehicles or fork-lift trucks. The following factors must be considered: door type and weight, closing system type and power, useful installation area, number of electromagnets, total consumption, available energy source and its autonomy, possible use of the release button on the electromagnet or a remote button. Each device must also allow manual operation, without affecting the functionality of the release device. Door status. To comply with accident prevention standards or specific directives, some magnets are provided with door status, which in combination with a magnetic contact on the frame, allow the central unit to identify the position of the door. 46 Fire System Components Toll Free Number

49 Technical info The door status is a contact that changes status when the counter-plate is released from the electromagnet (they are mainly used in France). Diodes. Some door-release units are provided with diodes for disturbance suppression and protection against power supply reversal, while some others are not equipped with such devices so that the installer can apply the most suitable devices according to the specifications of the power supply line. Release button: It is a button on the electromagnetic release unit that, cutting of power supply to the internal coil, allows to release the counter-plate and close the door. Remote manual release button. It is a release button located away from the electromagnet and installed near fire-resistant doors (it must not be covered by the door). Installation advice: It is important to identify the application point for the electromagnet and the corresponding counter-plate. Normally, the electromagnet is mounted on the wall, while the counter-plate must be located in the top area of the door wing. A key factor is the distance between the door-release unit and the door hinges: the shorter the distance, the lower the strength required to close the door manually. The electromagnetic units with release button must be installed in such a way that the button can be easily identified and accessed. Special attention must be paid that the electromagnet core and the counter-plate are installed in axis. The mounting supports for the electromagnet and counter-plate must be provided with screws or anchors adequately sized to withstand traction at least twice as strong as the electromagnet s nominal retaining strength. The keeper plate must be mounted with the TOP label upwards to avoid torsion that might damage it in the long run. Check the correct inclination of the plate, so that its surface is parallel to the core, then tighten the screw of the counter-plate joint. When the release unit is installed, the core and counter-plate must engage with a slight pressure on the door wing. The presence of even minor impurities between the electromagnet core and the counter-plate, or small dents due to accidental impact may prevent perfect union, causing a remarkable proportional reduction of nominal retaining strength. The surface must not be painted and, for optimal efficiency, must be cleaned periodically with a soft cloth (do not use water). Manual Call points Red manual Call points are employed for the manual signalling of a fire alarm (manual fire alarm points). Descriptions. Once the building has been divided into sections as prescribed by UNI 9795: there must be at least two manual signalling point in each section the call points must be installed in a suitable number, so that at least one call point can be reached from any location of the section with a maximum track of 40 m manual call points must be installed along the exit ways they must be installed in clearly visible locations and easily accessible at a height between 1 and 1.4 m they must be protected against accidental operation, mechanical damage and corrosion in case of activation, it must be possible to identify the activated manual signalling point locally (e.g. broken glass or altered colour of the button or LED) each manual signalling point must be clearly labelled with operating instructions and, for the break glass call points that cannot be broken simply with fingers, a glass breaking hammer. Colours: Manual call points are available in different colours besides red for other applications (provided with adhesive labels to identify their function) such as: door release in access control systems, extinction control, emergency stops, generic danger warning and other purposes. Operation: The Call points can work with direct operation (breaking the glass or pressing the fake glass will trigger the alarm) or indirect operation (it is necessary to break the glass and press the internal button). The finger must apply pressure onto the sensitive front element, which is normally a glass of suitable thickness protected by an antiinjury film, or a fake glass of plastic material. In some buttons, the glass must be broken with a specific hammer. A broken glass and/or the apparent colour alteration of the fake glass background indicate the button where the signal was started. According to the model, the button can be restored by means of a suitable tool or by replacing the broken glass. Fire System Components Toll Free Number

50 Technical info FIRE ALARM DEVICES The sound pressure of an alarm device is expressed in db(a), as explained hereunder. Sound pressure level and decibel (db) Sound pressure level (SPL) is the degree of variation of atmospheric pressure in a point due to sound. SPL is generally indicated at 1 m from the source. As the sound pressure range measured in practice has 6 orders of magnitude, a logarithmic scale in decibel (db) is applied to preserve a certain level of measurement accuracy. The formula for SPL is: SPL (db) = 20 log 10 (P/P0), where P is measured pressure and P 0 is the reference pressure that represents the hearing threshold: 20μPa (1 Pa = 1 N/m 2 ). The range of sound pressure levels in practice goes from 0 to 140 db (see table next). We remind that db calculations are based on the addition of sound pressure, not SPL. Double sound pressure corresponds to +6 db, while multiplication of the sound pressure by 10 equals +20 db. For a single-point sound source (remote field), the spherical attenuation of sound pressure according to distance can be derived from the equation: S d = S 0 20 log 10 (d/d 0 ), where d = distance from the source, d0 = distance from the source at which the SPL is known, Sd = SPL at d distance, S0 SPL at d0 distance. So, if distance doubles, sound pressure decreases by 6 db (20 log 10 2 = 6). Sound pressure levels are expressed, in practice, in db(a) to take into account the response curve of human ear to different frequencies and sound pressures. Letter A indicates the weighted curve used to filter the sound pressure measurement. SPL (db) Sound Pressure (μpa) Example Jet engine Propeller vehicle (pain threshold) Discotheque Industrial machinery Heavy vehicle Intense traffic Office 0 20 Hearing threshold Sounders. y emit a dual-tone or alternate signal or frequency Sweep. Normally, medium-low frequencies are use (1 khz approx.) for fire applications, and medium-high (3 khz approx.) for security applications. Sound pressure must be at least 65 db in one direction and not more than 120 db in all directions. The most popular sounders are electronic models with two different technologies: piezoelectric: they exploit the property of piezoelectric crystals, that deform elastically if subject to an electric field. The electric field is obtained by applying to a waffle made up of two metal electrodes with an intermediate piezoelectric material layer (normally ceramics). If the electric field is alternate, the piezoelectric waffle starts vibrating, generating an acoustic signal. The piezoelectric waffle must be coupled to the air impedance with a suitable diffuser. Very low consumption but very small range of reproducible frequencies. electromagnetic: they consist of a loudspeaker with permanent magnet; an electronic circuit feeds a moving coil with a frequency in the kilohertz range, which sets the diaphragm into vibration and consequently generates the emission of an acoustic signal. Current consumption is rather high, but a wide range of reproducible frequencies is available. Recently, voice message sounders have been introduced, which help reduce panic as, besides emitting an alarm tone, they can also play a recorded voice that informs people in the building about the actions to be taken. Some sounders are provided with beacon to provide also a visual alarm. BELLS. In the past, they were the only acoustic alarm device, now they are still used as, thanks to the high content of low-frequency harmonics in the signal, they can be heard at a distance also with physical barriers. OPTICAL ACOUSTICAL PANELS. Developed as options for fire detection systems, they are now commonly used as, besides issuing an acoustic signal, visually communicate with a message, reducing the disorientation of people in the room. In terms of information, the available writings, besides indicating the event under way, provide indicative information on the behaviour to be complied to, such as DO NOT ENTER or EVACUATE ROOM. The silk-screen printing process of the COOPER CSA panels, makes the writing almost invisible with turned-off panel, but very clear with turned-on panel. Different light sources are available: incandescence (fixed or intermittent light), Xeno (only intermittent light), fluorescent (only fixed light). Acoustical signalling is performed by means of piezoelectric buzzers with high sound pressure. Recently, self-supplied panels have also been introduced, which thanks to their battery, do not absorb current from the central unit, only requiring a simple activation command. The panels are generally installed at entrances and along escape routes from the monitored areas, in the higher part of the environments for easier identification. BEACONS. They emit a light signal in alarm conditions. The most popular are provided with Xeno lamp to generate very intense light flashes with minimum current consumption. OPTICAL and ACOUSTIC REPEATERS. They allow the remote transmission of the optical and/or acoustic signalling of alarms in the locations where the signals emitted by the main alarm devices are not perceptible. They have LED-based light sources and acoustical signalling by means of piezoelectric buzzer. 48 Fire System Components Toll Free Number

Intrusion and Fire System Components

Intrusion and Fire System Components Intrusion and Fire System Components Price list 06/202 Table of contents Intrusion System Components Fire System Components Microcontacts Power supply 27,6V 4 Concealed magnetic contacts Door release units

More information

Signaling Devices. Acoustic Signaling Devices 298. Optical Signaling Devices 309. Bosch Security Systems B.V.

Signaling Devices. Acoustic Signaling Devices 298. Optical Signaling Devices 309. Bosch Security Systems B.V. Signaling Devices Acoustic Signaling Devices 28 Optical Signaling Devices 30 26 Signaling Devices Acoustic Signaling Devices Acoustic Signaling Devices MSS300-SA SG 200 DS 10 LSN/GLT GLT GLT GLT Operating

More information

Kickspot Self-testing/AutoDiag self-contained emergency lighting unit

Kickspot Self-testing/AutoDiag self-contained emergency lighting unit CONTENTS Page 1. Description.............................1 2. Installation.............................2 3. Connection.............................4 4. Use......................................8 5. Maintenance...........................9

More information

ELECTRONIC SOUNDER STROBE Model : AVD-C407

ELECTRONIC SOUNDER STROBE Model : AVD-C407 ELECTRONIC SOUNDER STROBE Model : AVD-C407 MULTRON range of combination Electronic Sounders with Strobe Lights are designed to complement our Fire Alarm products both technically and aesthetically as an

More information

Yodalarm. Sounders. Pg Y03 Y04/YL4 Y05/YL5 Y08/YL8/Y08 SUPER/ YL8 SUPER V4 V6/Y06/YL6 Carillon

Yodalarm. Sounders. Pg Y03 Y04/YL4 Y05/YL5 Y08/YL8/Y08 SUPER/ YL8 SUPER V4 V6/Y06/YL6 Carillon Sounders Y03 Y04/YL4 Y05/YL5 Y08/YL8/Y08 SUPER/ YL8 SUPER V4 V6/Y06/YL6 Carillon Pg 185 186 187 188 189 190 191 Y03 1YA030207 1YA030203 1YA030205 YL030/24 A1:2002 YL030110/230 UL464 C22.2 No. M1983 BS

More information

Fire Signalling. Signalling Solutions

Fire Signalling. Signalling Solutions Fire Signalling Signalling Solutions Introduction Introduction Klaxon Signals manufactures the world s largest range of sound signalling equipment and solutions for the European and worldwide market place.

More information

FlexSQUARE Square shaped beacons

FlexSQUARE Square shaped beacons FlexSQUARE Square shaped beacons Size comparison Mini/Midi/Maxi Optical LED Permanent Light 5 LED Flashing Light 6 LED EVS 8 Your benefits The compact LED beacon is particularly versatile. With an IP67

More information

VIMPEX BS Evacuation. Fire Alarms EN Banshee. Beacons. FlashDome. Electronic Sounders. Audible Alarm

VIMPEX BS Evacuation. Fire Alarms EN Banshee. Beacons. FlashDome. Electronic Sounders. Audible Alarm VIMPEX Sounder Range Fire Alarms Banshee Electronic Sounders FlashDome EN 54-3 Evacuation Audible Alarm BS 5839-1 Beacons The range of sounders, beacons, sounder beacons and accessories represents the

More information

Fire Products Catalogue

Fire Products Catalogue Fire Products Catalogue Safety Contents S OUNDE R S PAG E R olp - S ounder R olp Maxi - C S 200 S ounder P age Squashni G3 - Platform Sounder 9 Askari C ompact - S ymphoni - S ounder S ounder Symphoni

More information

Fire alarm devices Product overview. Ensure a safer future

Fire alarm devices Product overview. Ensure a safer future Fire alarm devices Product overview Ensure a safer future Eaton and Cooper united. Energizing a world that demands more. We deliver: Electrical solutions that use less energy, improve power reliability

More information

Safe & hazardous area. Industrial products catalogue

Safe & hazardous area. Industrial products catalogue Safe & hazardous area Industrial products catalogue Contents SOUNDERS PAGE Page Asserta Maxi Sounder 6 Asserta Midi Sounder 7 Asserta Mini Sounder 8 Askari Panel - Sounder 9 Askari Flange - Sounder 10

More information

FIRE AND SAFETY. Manual Call Points p15-1 Magnetic Door Holders p15-3 Detection Cables p15-4 Portable Signals p15-7 Solar Powered Signals p

FIRE AND SAFETY. Manual Call Points p15-1 Magnetic Door Holders p15-3 Detection Cables p15-4 Portable Signals p15-7 Solar Powered Signals p FIRE AND SAFETY Manual Call Points p15-1 Magnetic Door Holders p15-3 Detection Cables p15-4 Portable Signals p15-7 Solar Powered Signals p15-10 Perth (08) 9248 0410 Sydney (02) 9676 1671 Melbourne (03)

More information

Conventional Fire Detection

Conventional Fire Detection SECTI 4: page 1 Section 4: Conventional Fire Detection Contents System Architecture Control Panel Automatic & Manual Detection Manual Call Points Smoke Detectors Heat Detectors Beam Smoke Detectors Duct

More information

CONTENTS NBM-06 Bell (6") Page 1

CONTENTS NBM-06 Bell (6) Page 1 CONTENTS NBM-06 Bell (6") - - - Page 1 NBM-08 Bell (8") - - - Page 1 LFB-24 Sounder Banshee - Page 2 VCT--NT Base Version Sounder Page 2 VCT--NT Wall Version Sounder Page 2 VRS1-R or W Bedhead Sounder

More information

The complete conventional fire warning system

The complete conventional fire warning system The complete conventional fire warning system www.espuk.com MAG2P 2 Zone Fire Panel 2 programmable zones Active end of line monitoring and head removal 30 fire detectors per zone Unlimited number of call

More information

Fire Signalling. Signalling Solutions

Fire Signalling. Signalling Solutions Fire Signalling Signalling Solutions Introduction Introduction Klaxon Signals manufactures the world s largest range of sound signalling equipment and solutions for the European and worldwide market place.

More information

Xenex Conventional Fire Detection & Alarm System

Xenex Conventional Fire Detection & Alarm System SECTI 4: page 1 Section 4: Xenex Conventional Fire Detection & Alarm System SECTI 4: page 3 Xenex system architecture Beam Transmitter Beam Receiver End of Line Call Point Smoke Detector Smoke Detector

More information

Addressable Loop Powered Visual Alarm Devices

Addressable Loop Powered Visual Alarm Devices Addressable Loop Powered Visual Alarm Devices About Who is? has a long and proud tradition in fire detection. Founded in Munich in 1877 as Elektrotechnische Fabrik Alois it quickly became a recognized

More information

intelligent solutions

intelligent solutions Alco is one of the leading intelligent solution providers of Fire Detection System. Security System and Public Addressing System in the United States of America. Based in California since 1992, we have

More information

SISTEMAS DE SEGURIDAD MIRA, S.L. COMPANY & PRODUCT GUIDE

SISTEMAS DE SEGURIDAD MIRA, S.L. COMPANY & PRODUCT GUIDE SISTEMAS DE SEGURIDAD MIRA, S.L. COMPANY & PRODUCT GUIDE Sistemas de Seguridad Mira, S.L. focuses on the design, development and manufacture of advanced components for fire detection systems. To secure

More information

What is conventional fire detection?

What is conventional fire detection? Contents What is conventional fire detection? 2 Conventional central units 3 Power supply 4 Conventional detectors 5 Conventional pushbuttons 6 Extinguishing system signs 7 Sirens and bells 8 Indicators

More information

Notifier by Honeywell: Non-Addressable Audible & Visual Alarm Devices. Approved to EN54-3/EN54-23

Notifier by Honeywell: Non-Addressable Audible & Visual Alarm Devices. Approved to EN54-3/EN54-23 Notifier by Honeywell: Non-Addressable Audible & Visual Alarm Devices Approved to EN54-3/EN54-23 Setting the Standard EN54-23 and how it affects you EN54-23 is a new European standard for Visual Alarm

More information

IST IST /110 IST /220

IST IST /110 IST /220 IST-07-11160 IST-07-11160/110 IST-07-11160/220 Electroimán retenedor de puertas 60kg Electromagnetic Door Holders IST-0711160 are attractively designed and ruggedly constructed. The contact plate can be

More information

DICTATOR Hold-Open Systems for Hazardous Areas

DICTATOR Hold-Open Systems for Hazardous Areas DICTATOR for Hazardous Areas Products to be used in hazardous areas obviously have to meet special demands. The European ATEX directives (first the EN 94/9/EG and then the directive 2014/34/ EU) brought

More information

DBS721, DBS729 Sounder interbase, Sounder beacon interbase

DBS721, DBS729 Sounder interbase, Sounder beacon interbase DBS721, DBS729 Sounder interbase, Sounder beacon interbase For the automatic addressable detector bus C-NET Cerberus PRO Sounder interbase DBS721 and sounder beacon interbase DBS729 11 selectable tones,

More information

INSTALLATION MANUAL SOUNDER MODELS RIALTO L LS X LSX TRIADE L LS QL QLS LIDO L X LS LSX

INSTALLATION MANUAL SOUNDER MODELS RIALTO L LS X LSX TRIADE L LS QL QLS LIDO L X LS LSX INSTALLATION MANUAL SOUNDER MODELS RIALTO L LS X LSX TRIADE L LS QL QLS LIDO L X LS LSX DESCRIPTION L models description: self-powered 12 Vdc sounder with high-brightness low-consumption LED flashing unit

More information

Overview. Wireless Overview QLD NSW VIC Fundamentals. Operation. Features.

Overview. Wireless Overview QLD NSW VIC Fundamentals. Operation. Features. Wireless Overview www.incitefire.com.au Overview Fundamentals FIREwave is a wireless based family of products which is fully integrated into Hochiki s renowned ESP intelligent hardwired system. This seamless

More information

Synova TM product catalog.

Synova TM product catalog. Synova product catalog Synova TM product catalog. Fire protection products and accessories. Siemens Switzerland Ltd Building Technologies Group International Headquarters Gubelstrasse 22 CH-6301 Zug Tel

More information

Intellia Sounder Bases and Sounder Beacon Bases

Intellia Sounder Bases and Sounder Beacon Bases Intellia Bases and Beacon Bases The Base and Beacon Base are a local-area alarm devices designed for indoor use. They can be connected only to detection systems using Intellia detectors and FX control

More information

are you ready for some inspiration?...

are you ready for some inspiration?... are you ready for some inspiration?... 2 Cooper Industries Cooper Industries was originally formed in 1833 as a foundry business in Ohio, USA. It has since grown to become a $5.2 billion turnover global

More information

USE AND INSTALLATION HANDBOOK

USE AND INSTALLATION HANDBOOK Date : 30/10/14 Rev. 02 PR.T : FG006203 USE AND INSTALLATION HANDBOOK (SLA1) ALARM1, ALARM2 ALARM WITH BUFFER BATTERY Via Enrico Fermi, 8-35020 Polverara PD Tel.049/9772407 Fax.049/9772289 www.fourgroup.it

More information

Applications: 27. NETIChome mobile ios 28. NETIChome mobile Android. NETIChome basic elements

Applications: 27. NETIChome mobile ios 28. NETIChome mobile Android. NETIChome basic elements INDEX 1 NETIC... 2 2 Door/Window detector MINI... 2 3 FOUR sensor... 3 4 Smoke detector... 3 5 Flood detector... 4 6 ILLumination sensor... 4 7 Lamp holder... 5 8 Siren... 5 9 Power meter & switch... 6

More information

EFBW series - BiWire Ultra control panel

EFBW series - BiWire Ultra control panel 4.2 Control panels and repeater panels EFBW series - BiWire Ultra control panel Eaton s new BiWire Ultra fire detection system is unlike any other standard conventional system as the panel, conventional

More information

XEON. High impact resistant body and PC cover. Double layer coating. through wiring. Build-in microwave sensor.

XEON. High impact resistant body and PC cover. Double layer coating. through wiring. Build-in microwave sensor. XEON is a rectangular shape wall or ceiling fixture. This luminaire family has a robust aluminium construction housing with a high impact resistant polycarbonate diffuser. It is to be operated with LED

More information

PolyGard 2-channel Gas Controller MGC-03

PolyGard 2-channel Gas Controller MGC-03 PolyGard 2-channel Gas Controller MGC-03 DESCRIPTION Gas measuring and monitoring controller based on state-ofthe-art micro-technology with integrated buzzer for continuous monitoring of the ambient air

More information

INFRARED MODULATED BARRIERS

INFRARED MODULATED BARRIERS INFRARED MODULATED BARRIERS riello elettronica group INFRARED BARRIERS WITH ADJUSTABLE LENSES FULL FULL SYNCRO POWER SUPPLY 12/24 Vac-dc MAXIMUM RANGE UNDER IN CONDITIONS 15 METRES CONFORMS TO THE SAFETY

More information

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices. FireCell Radio Hub Fully addressable Wireless activation Third party approved (EN54) 2-way radio communication Loop powered Diagnostics port Range in excess of 150 metres Overview The model FCX-500-001

More information

Fire Signalling. Signalling Solutions

Fire Signalling. Signalling Solutions Fire Signalling Signalling Solutions Introduction Introduction Klaxon Signals manufactures the world s largest range of sound signalling equipment and solutions for the European and worldwide market place.

More information

Star Headlight & Lantern Co., Inc. Company Presentation. Leader in Warning, Emergency Lighting and Signaling Products

Star Headlight & Lantern Co., Inc. Company Presentation. Leader in Warning, Emergency Lighting and Signaling Products Company Presentation Leader in Warning, Emergency Lighting and Signaling Products Founded on April 20, 1889 by five initial owners. Four months later, George Washington Jacobs purchased the controlling

More information

CONFIGURATION OF THE OPTICALS

CONFIGURATION OF THE OPTICALS Technical manual INDEX 1 MAIN COMPONENT LIST Pag. 3 2 MOUNTING EXAMPLES Pag. 4 MOUNTING WITH BRACKETS Pag. 5 3 INSTALLATION SAMPLES Pag. 6 4 CONFIGURATION OF THE OPTICALS Pag. 7 OPTICAL TX Pag. 7 OPTICAL

More information

INSTRUCTION MANUAL T119 1MN0110 REV. 0. operates with ISO9001 certified quality system

INSTRUCTION MANUAL T119 1MN0110 REV. 0. operates with ISO9001 certified quality system INSTRUCTION MANUAL 1MN0110 REV. 0 operates with ISO9001 certified quality system TECSYSTEM S.r.l. 20094 Corsico (MI) Tel.: +39-024581861 Fax: +39-0248600783 http://www.tecsystem.it R. 1.1 25/08/16 ENGLISH

More information

Commercial and Light Industrial Fire Alarm Control Panel

Commercial and Light Industrial Fire Alarm Control Panel FireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel Features Easily expandable. All new plug-in board design Two supervised audible circuits Lamp and system trouble circuit test Ground

More information

Interface and EOL Modules 8

Interface and EOL Modules 8 Interface and EOL Modules Interface Modules Series 420 25 Interface Modules Series 100 291 EOL Modules 293 254 Interface and EOL Modules Interface Modules Series 420 Interface Modules Serie 420 Interface

More information

SOL-LX-W, SOL-LX-C, RoLP-LX, RoLP Sounder, beacon, and sounderbeacon

SOL-LX-W, SOL-LX-C, RoLP-LX, RoLP Sounder, beacon, and sounderbeacon SOL-LX-W, SOL-LX-C, RoLP-LX, RoLP Sounder, beacon, and sounderbeacon alarm devices For fire detector and extinguishing systems Loud alarm signal clearly recognizable as a danger signal even in noisy environments

More information

Loop units. a wide range covering your basic fire detection needs

Loop units. a wide range covering your basic fire detection needs Loop units a wide range covering your basic fire detection needs We provide a wide range of loop units for our fire detection systems. Our detectors, manual call points, I/O units, control units and alarm

More information

Nightfall. led emergency egress lighting

Nightfall. led emergency egress lighting Nightfall led emergency egress lighting Nightfall led emergency egress lighting Combining a sleek, architectural, low profile design with high performance makes the Nightfall Series an attractive LED solution

More information

Conventional Leaflets

Conventional Leaflets Conventional Leaflets Panels Last updated October 1999 Make leaflet selection by clicking on appropriate bookmark Return to Menu Installation and Basic Commissioning guide for the range of 1,2,4 and 8

More information

Addressable and Conventional Fire Protection

Addressable and Conventional Fire Protection Addressable and Conventional Fire Protection Simply reliable F I R E P R O T E C T I O N The MAGPro and Fireline systems has been created to balance performance, reliability and aesthetics whilst being

More information

Multi-Gas-Controller MGC2

Multi-Gas-Controller MGC2 Page 1 Aug. 2018 Gas measuring, monitoring and warning controller based on state-of-the-art micro-technology for continuous monitoring of the ambient air to detect toxic and combustible gases, refrigerants

More information

Opal TM AV Devices. Data Sheet. Benefits

Opal TM AV Devices. Data Sheet. Benefits Opal TM AV Devices Data Sheet Notifier s Opal AV (Audio Visual) range is designed to alert building occupants of an emergency. The Opal AV range of analogue addressable, loop powered, audible and visual

More information

signaling solutions from auer signal

signaling solutions from auer signal Modular Series and Visual /Audible Series signaling solutions from auer signal Five Types of Interchangeable Simple Twist & Heavy Duty Illumination Components Release Modules Construction Modular Beacon

More information

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS QUICK USER GUIDE FOR, 2 & 4 ZONE PANELS INDICATORS COLOUR INDICATION MON FAULT Yellow On when a fault condition has occurred, or if no other fault Led is on, this indicates 24v auxiliary fuse failure.

More information

BEKA / EMERGENCY SIGNAGE LUMINAIRE RANGE FROM DAISALUX S.A. EMERGENCY

BEKA / EMERGENCY SIGNAGE LUMINAIRE RANGE FROM DAISALUX S.A. EMERGENCY BEKA / EMERGENCY SIGNAGE FROM DAISALUX S.A. EMERGENCY ARGOS EMERGENCY SIGNAGE Ceiling Suspended Wall bracket VERSIONS/DIMENSIONS IN MM SINGLE SIDED Semi-recessed DOUBLE SIDED SEMI-RECESSED Surface CEILING

More information

>WIRELESS> ALARM SYSTEM CR200

>WIRELESS> ALARM SYSTEM CR200 intrusion >WIRELESS> ALARM SYSTEM CR200 INTRUSION HOME SECURITY CR200 is a Modern, Effective and Versatile 20-zone Household Security System. It is packed with simple Plug & Play functionality, designed

More information

For Complete Fire and Gas Solutions

For Complete Fire and Gas Solutions Industrial Fire For Complete Fire and Gas Solutions 2 The Total Package What do you need from an integrated fire and gas system? In industrial fire and gas environments it s important to have a reliable

More information

NEMA-4X Series. Certified for Harsh Environment Applications

NEMA-4X Series. Certified for Harsh Environment Applications NEMA-4X Series Certified for Harsh Environment Applications NEMA-4X Family The industry standard for emergency lighting in harsh environments is here. Battery units, remote fixtures, exit signage and combination

More information

Architectural / led luminaires

Architectural / led luminaires Introducing... An indoor/outdoor architecturally styled high performance LED Luminaire available with normally-on operation powered by line voltage, emergency operation powered by a Nickel-Cadmium battery

More information

I Notification. Loudspeaker HONEYWELL COMMERCIAL VOICE ALARM AUDIO

I Notification. Loudspeaker HONEYWELL COMMERCIAL VOICE ALARM AUDIO I Notification Loudspeaker HONEYWELL COMMERCIAL VOICE ALARM AUDIO Honeywell is a Fortune 100 company that invents and manufactures technologies to address tough challenges linked to global macro trends

More information

SYSTEM MANUAL FT1-SB. Single Zone Fire Alarm System

SYSTEM MANUAL FT1-SB. Single Zone Fire Alarm System SYSTEM MANUAL FT1-SB Single Zone Fire Alarm System DOCUMENT HISTORY Issue Date Description Written By Checked By Draft 0 2/9/2008 Original Document. A. Shenouda C. Orr Issue 1 4/11/2011 Update drawing

More information

"Pegaso" wireless alarm system

Pegaso wireless alarm system "Pegaso" wireless alarm system Summary Page 1.0. Description... 2 2.0. Installation... 3 3.0. Connections to mains power... 4 4.0. Low battery signalling... 4 5.0. Service key... 5 6.0. Selection of functions...

More information

Touchpoint Plus. A whole new control experience

Touchpoint Plus. A whole new control experience Touchpoint Plus A whole new control experience Touchpoint Plus Delivering reliable control Honeywell reliability from the most trusted experts in gas detection Built-in battery backup for constant uptime

More information

EX-SIGNAL- AND ESCAPE SIGN LUMINAIRS

EX-SIGNAL- AND ESCAPE SIGN LUMINAIRS 1 EX-SIGNAL- AND ESCAPE SIGN LUMINAIRS 2 Co op er Cr ou se -H inds 20 08 - al l ri gh ts re se rv ed 3 4 5 6 7 8 EMERGENCY LIGHTING CENTRAL OR DECENTRAL 3.21 EX-ESCAPE SIGN LUMINAIRES EXIT EX-ESCAPE SIGN

More information

INSTRUCTION MANUAL (ATEX / IECEx)

INSTRUCTION MANUAL (ATEX / IECEx) INSTRUCTION MANUAL (ATEX / IECEx) BExS110D and BExS110D-R Sounder For use in Flammable Gas and Dust Atmospheres BExS110D BExS110D-R 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT

More information

FDS229-R / FDS229-A Alarm sounder with supplementary optical indication

FDS229-R / FDS229-A Alarm sounder with supplementary optical indication FDS229-R / FDS229-A Alarm sounder with supplementary optical indication For the automatic addressable detector bus C-NET and FDnet Cerberus PRO Sinteso Alarm sounder with 11 tonalities selectable, 2 activation

More information

Consultant Specification AGILE Wireless Fire Detection System

Consultant Specification AGILE Wireless Fire Detection System Contents Scope of Work... 2 The EN54 Part 2 & 4 Fire System... 2 Standards... 2 Wireless Intelligent Photoelectric Smoke Detector Specification... 4 Wireless Intelligent Thermal Heat Detector Specification...

More information

Industries. As a premier global manufacturing company, we believe that great brands are

Industries. As a premier global manufacturing company, we believe that great brands are JSB Fire Systems ONE COOPER Every day, thousands of people all over the world use products made by Cooper Industries. As a premier global manufacturing company, we believe that great brands are built on

More information

MEDICAL REFRIGERATORS

MEDICAL REFRIGERATORS MEDICAL REFRIGERATORS erators / blood bank refrigerators / combined refrigerator-freezers / laboratory freezers /laboratory and pharmacy refrigerators / blood bank refrigerators / combined refrigerator-freezers

More information

AUTOMAX devices for the automation industry

AUTOMAX devices for the automation industry AUTOMAX devices for the automation industry INDEX INTRODUCTION...2 MACHINE DIRECTIVE...4 allcolor allclear PROXIMITY...6 TWS...8 MOUNTING COMBINATIONS...9 TWS BASE...10 TWS LED...11 TWS S...12 TWS RGA...13

More information

DUAL OPTIC. Installation manual

DUAL OPTIC. Installation manual DUAL OPTIC Installation manual INDEX 1 COMPONENTS Pag. 3 2 MOUNTING EXAMPLES Pag. 4 MOUNTING WITH BRACKETS Pag. 5 3 INSTALLATION EXAMPLES Pag. 6 4 CABLES AND CABLING Pag. 7 CONNECTION AND HEATING SETTING

More information

Quick Selection Guide Fire Systems LSN Periphery

Quick Selection Guide Fire Systems LSN Periphery Local SecurityNetwork Easy wiring Auto configuration capability (self-learning mode) Central programming of all device configurations from the panel Flexible network structure (Loop, stub, T-tap & mixed

More information

INDEX. Installation recommendation

INDEX. Installation recommendation Technical manual INDEX 1 MAIN COMPONENTS Pag. 3 2 ASSEMBLING THE CABLEPIT Pag. 4 CABLE PIT POSITIONING Pag. 6 3 BASE INSTALLATION ON CABLE PIT Pag. 8 4 INSTALLATION EXAMPLES Pag. 9 5 CONFIGURATION OF THE

More information

HART XL High Sensitivity Smoke Detection

HART XL High Sensitivity Smoke Detection High Sensitivity Smoke Detection Hart XL High Sensitivity Smoke Detection (HSSD) TM is a smoke detection system that is simple to install, commission, service and use yet remains brilliantly capable in

More information

MINERVA MX. 800 Series Ancillary Equipment

MINERVA MX. 800 Series Ancillary Equipment An extensive range of ancillary modules has been specifically designed for use with the MX range of Fire Controllers. The 800 range of ancillary modules provide the MX Fire Controller with a wide degree

More information

GENERAL CATALOGUE. FIRE AND SAFETY - Edition Rev. 4

GENERAL CATALOGUE. FIRE AND SAFETY - Edition Rev. 4 GENERAL CATALOGUE FIRE AND SAFETY - Edition 2017-1 Rev. 4 All data have been written and checked with the utmost care. Possible errors or omissions do not constitute reason for complaint. The information

More information

INERIS 01ATEX0060 (standard) TR CU (marking upon request, ordering code to be required)

INERIS 01ATEX0060 (standard) TR CU (marking upon request, ordering code to be required) FLUORESCENT LIGHTING RMS-560.. Series - Fluorescent lighting fixtures TECHNICAL FEATURES RMS.. series lighting fixtures are ideally suited for ON and OFF-SHORE applications and all kinds of industries

More information

OPERATION AND INSTALLATION MANUAL

OPERATION AND INSTALLATION MANUAL EX+Plus 2 ZONE, 1AREA EXTINGUISHANT CONTROL PANEL OPERATION AND INSTALLATION MANUAL INTRODUCTION The Premier EX Plus is a 2 zone, single area panel for controlling the release of extinguishing gases in

More information

ICARO. Aircraft Warning Lights GENERAL CATALOGUE

ICARO. Aircraft Warning Lights GENERAL CATALOGUE ICARO Aircraft Warning Lights GENERAL CATALOGUE ICARO Aircraft Warning Lights INDEX INTRODUCTION... 2 WARNING LIGHTS AWL 810/AB... 4 AWL 810/AB TWIN... 5 WARNING LIGHTS AWL 864/BC... 6 AWL 864/BC TWIN...

More information

PRODUCT OFFERING QUALITY VALUE VERSATILITY

PRODUCT OFFERING QUALITY VALUE VERSATILITY PRODUCT OFFERING QUALITY VALUE VERSATILITY LED FAMILY The Compass LED product series includes economical energy saving fixtures suitable for use in any commercial or light industrial application. Value

More information

Gas leak detection system. for heating rooms and similar environments. Description. Sensor for methane gas IP44. Sensor for LPG gas IP44

Gas leak detection system. for heating rooms and similar environments. Description. Sensor for methane gas IP44. Sensor for LPG gas IP44 s 7 603 INTELLIGAS Gas leak detection system for heating rooms and similar environments Electronic control unit for gas leak detection with up to 4 sensors aimed to drive one or two gas flow cut-off 12VD

More information

1200-HCM DIN RAIL MOUNTING FIRE SYSTEM MODULE Fire Detection & Extinguishant Control A R T PATOL LIMITED SUPPLY FAULT SOUNDER

1200-HCM DIN RAIL MOUNTING FIRE SYSTEM MODULE Fire Detection & Extinguishant Control A R T PATOL LIMITED SUPPLY FAULT SOUNDER Application The unit is primarily intended for use where there is a requirement to integrate a limited fire protection function into a larger control equipment scheme, or in specialist applications where

More information

Movement-based energy control

Movement-based energy control 04 Movement-based energy control 94 International catalogue 2015 4.1 Microwave-based movement sensors 4.2 PIR-based movement sensors 4.2.1 Ceiling-mount 4.2.2 Wall-mount 4.3 Twilight switches 4.4 LED lights

More information

INDEX. Installation recommendation

INDEX. Installation recommendation Technical manual INDEX 1 MAIN COMPONENTS Pag. 3 2 ASSEMBLING THE CABLEPIT Pag. 4 CABLE PIT POSITIONING Pag. 6 3 BASE INSTALLATION ON CABLEPIT Pag. 8 4 INSTALLATION EXAMPLES Pag. 9 5 WIRING Pag. 10 6 CONFIGURATION

More information

Bulb Overview DESCRIPTION PART NO. TOTAL VOLTAGE FOR USE WITH: LENGTH(mm) Free-standing Beacons Accessories. Optical Signal Devices

Bulb Overview DESCRIPTION PART NO. TOTAL VOLTAGE FOR USE WITH: LENGTH(mm) Free-standing Beacons Accessories. Optical Signal Devices Bulb Overview PART NO. DESCRIPTION TOTAL LENGTH(mm) VOLTAGE FOR USE WITH: 955 840 34 Bulb BA15d 5 W 42 12 V 200 203 209 641 800 840 845 955 840 35 Bulb BA15d 5 W 42 24 V 200 203 209 641 800 840 845 955

More information

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels Installation and user manual for the FX range of fire panels 1, 2, 4 and 8 zone panels Contents Panel installation 3 Panel connections 3 Wiring connection drawings 4 Panel facilities 6 Installation check

More information

Sigma. K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels. Operation and Maintenance Manual. Man-1048 Issue 05 October 2009

Sigma. K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels. Operation and Maintenance Manual. Man-1048 Issue 05 October 2009 Sigma K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels Operation and Maintenance Manual Man-1048 Issue 05 October 2009 CONTENTS Contents... Page Safety & Installation...2 Installation - continued...3

More information

Conventional Audible Visual Range

Conventional Audible Visual Range Conventional Audible Visual Range Visual Devices Non-Addressable Audible Visual Devices Base Sounder Honeywell s conventional audible visual devices operate over a wide input voltage range of 9 to 33VDC

More information

signaling solutions visual signaling signal towers Audible signaling

signaling solutions visual signaling signal towers Audible signaling visual signaling signal towers Audible signaling Sprecher + Schuh is the exclusive Authorized Distributor for Auer Signaling Products in North America. signaling solutions QUALITY SIGNALING SOLUTIONS More

More information

RAZOR RZR SERIES DIE CAST ALUMINUM LED EXIT SIGNS INSTALLATION AND OPERATING INSTRUCTIONS IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

RAZOR RZR SERIES DIE CAST ALUMINUM LED EXIT SIGNS INSTALLATION AND OPERATING INSTRUCTIONS IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS RAZOR RZR SERIES DIE CAST ALUMINUM LED EXIT SIGNS INSTALLATION AND OPERATING INSTRUCTIONS IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including

More information

Alarm System. Enjoy the Security. Enjoy Simple Life KERUI Doorbell. Security and Protection. Leading Brand of Intelligent. Present by Secrui Group

Alarm System. Enjoy the Security. Enjoy Simple Life KERUI Doorbell. Security and Protection. Leading Brand of Intelligent. Present by Secrui Group Enjoy the Security Alarm System Leading Brand of Intelligent Security and Protection 中国移动 GSM 11:25 Enjoy Simple Life KERUI Doorbell Present by Secrui Group Shenzhen Secrui Electronic Co., ltd is a professional

More information

OPERATION & INSTALLATION MANUAL FOR ALARM PANEL M2AP01

OPERATION & INSTALLATION MANUAL FOR ALARM PANEL M2AP01 OPERATION & INSTALLATION MANUAL FOR ALARM PANEL M2AP01 Table of Contents Safety Instructions 4 Owner/Operator Responsibility 4 Specifications 5 Introduction 6 Installation Instructions 7 Setup 7 Wiring

More information

perimeter barriers Active infrared SAFET Y INSIDE AND OUTSIDE THE HOME WALL-FLUSH INTERNAL OR EXTERNAL PROTECTION EXTERNAL PROTECTION

perimeter barriers Active infrared SAFET Y INSIDE AND OUTSIDE THE HOME WALL-FLUSH INTERNAL OR EXTERNAL PROTECTION EXTERNAL PROTECTION Active infrared The recently updated range of Prastel active infra-red offers many solutions: WALL-FLUSH INTERNAL OR EXTERNAL PROTETION For short range perimeter protection (doors, windows, balconies)

More information

CONVENTIONAL >FIRE DETECTION C400 SYSTEM FIRE DETECTION

CONVENTIONAL >FIRE DETECTION C400 SYSTEM FIRE DETECTION FIRE DETECTION >FIRE DETECTION CONVENTIONAL C400 SYSTEM FIRE DETECTION EFFICIENT AND MODULAR Elkron fire detection systems protect your business and grow with it Elkron's conventional fire detection range

More information

ARRAN LED LED FLOODLIGHT. Standard Specification. Features

ARRAN LED LED FLOODLIGHT. Standard Specification. Features ARRAN LED LED FLOODLIGHT The Arran LED floodlight range is low energy with an instant on output and up to 130,000 maintenance free hours. Specifically designed for applications where moisture, dirt or

More information

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres 1) Introduction The BExBG05D-SIL is a flameproof beacon which is certified

More information

XC10 Extinguishing control panels

XC10 Extinguishing control panels XC10 Extinguishing control panels Market package 2.1 Advanced control panels for detection and alarming as well as for the activation of the extinguishing process Microprocessor-controlled fire detection

More information

Ultrasonic Switches. Features & Benefits

Ultrasonic Switches. Features & Benefits Why use an ultrasonic switch over other level technologies? Depending upon your application, there may be three or four technologies equally suited for your application; however; only one will be the best

More information

INDEX. Installation recommendation

INDEX. Installation recommendation Technical manual INDEX 1 MAIN COMPONENTS Pag. 3 2 MOUNTING SAMPLES Pag. 4 MOUNTING WITH BRACKETS Pag. 5 3 INSTALLATION SAMPLES Pag. 6 4 WIRING Pag. 7 5 CONFIGURATION OF THE OPTICALS Pag. 8 OPTICAL TX Pag.

More information

Engineering Guideline. pac-carriers Type SIEMENS ET-200M Fail-safe signal modules

Engineering Guideline. pac-carriers Type SIEMENS ET-200M Fail-safe signal modules Engineering Guideline pac-carriers Type 9195 SIEMENS ET-200M Fail-safe signal modules pac-carrier Type 9195 2 Engineering Guideline/SIEMENS 19.05.2015 pac-carrier Type 9195 Integration of conventional

More information

SP-4004 OPTICAL-ACOUSTIC OUTDOOR SIREN sp4004_en 03/13

SP-4004 OPTICAL-ACOUSTIC OUTDOOR SIREN sp4004_en 03/13 SP-4004 OPTICAL-ACOUSTIC OUTDOOR SIREN sp4004_en 03/13 The SP-4004 siren provides information about alarm situations by means of optical and acoustic signaling. The device is designed for outdoor installation.

More information

SOUNDER BASES AND SOUNDER BEACON BASES

SOUNDER BASES AND SOUNDER BEACON BASES Tech Data Sheet D01513GB3 44/2011 Fire Detection SOUNDR BASS AND SOUNDR BACON BASS Intellia Sounder Bases and Sounder Beacon Bases The Sounder Base and Sounder Beacon Base are a local-area alarm devices

More information